November 2005 DUAL AXIS FLUXGATE MAGNETOMETER WITH FIXED CORE AND CLEAR CENTRE FEATURES TWO AXIS SENSE WINDINGS FOR 360 RANGE AVAILABLE IN TWO SENSITIVITIES CLEAR CENTRE FOR SHAFT CAN SUPPORT BEARINGS LARGE DIAMETER FOR HIGH ACCURACY
Single impact 60Hz, 10Min +71C at 95% Humidity -20C at 85% Humidity
SPECIFICATIONS
PARAMETER ERROFFSET ERRLIN DESCRIPTION Offset Error Linearity Error NOTES TYPICAL VALUE 3 1 UNIT Degrees Degrees
ORDER INFORMATION
PART A1014-1 A1014-4 EVS-1 DESCRIPTION Fluxgate, fixed core, sensitivity optimised for Earths field Fluxgate, fixed core, sensitivity optimised for 10mT magnet Fluxgate Evaluation Kit
A1014-X
A1014-1
SENSE WINDINGS
DESCRIPTION DC Resistance Inductance NOTES MAX UNIT Ohms mH
PARAMETER RS LS VS
Typical Output
V/mT
A1014-4
EXCITATION WINDING
DESCRIPTION Saturation Current DC Resistance Inductance NOTES 1 CONDITIONS MIN TYP TBA 7.1 TBA TBA TBA TYP 42 TBA TBA TBA TBA MAX UNIT mA Ohms mH
PARAMETER IE(SAT) RE LE
A1014-4
SENSE WINDINGS
DESCRIPTION DC Resistance Inductance NOTES MAX UNIT Ohms mH
PARAMETER RS LS VS
Typical Output
V/mT
NOTES:
1. IE(SAT) is defined as the current required to reduce effective permeability of core to the point where winding inductance measures within 2% of that of an equivalent sized air-cored coil. 2. Measured in UK, horizontal component of Earths magnetic field = 60 T 3. Measured using a Wavetek 27XT inductance meter. Fluxgate under test was wound with two identical excitation windings. First winding was connected to DC current source, while inductance was measured on second winding. 4. Measured using a Wavetek 27XT inductance meter.
A1014-X
Sense Winding
1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.1 1 10 Excitation Current (mA) 100 Inductance (mH)
4,45 4,45
4X P D33.0 C
2 3 4 5 6 1 20 19 18 17
4,45
20.0
16 15 14 13 12 11
5,8
10
30
20 S NE X ES 7 17 19 S NE X ES 10
1 6,3
18 16 14 12 10 8 6 4 2 0 0.1
Excitation Winding
Inductance (mH)
E C A IO X IT T N 6 14 S NE Y ES 11 1 S NE Y ES 16
Autonnic, the *A logo and Fluxgateworld are registered Trade Marks of Autonnic Research Ltd. Copyright Autonnic Research Ltd 2003 Document A1014-03
www.autonnic.com