ST RUNNER 4 TO 8 ALARM DIAGRAM AND INSTALLATION MANUAL Version 1.

The information presented in this booklet is intended to reflect the most common diagrams utilised by installers when commissioning a ST Runner system. For assistance with wiring diagrams and programming your ST Runner system, please contact your local agent or Housewatch direct on :Phone; 1300 472 472 Fax; 1300 672 672
1

NOTE
NOTE if NOT using a sensor (PIR) in the System, a 2.2k RESISTOR MUST be used across the zones

If not using the 2.2k resistor in the system you MUST change the programming All wiring diagrams are all with a 2.2k resistor in them

INDEX 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Wiring PIRs ...................................................................... 4-9 Double Zone Wiring Diagram.......................................... 10,11 Installing Single Channel Receiver.................................. 12 Installing Four Channel Receiver.................................... 13 Setting Away and Stay modes with 4 Channel Receiver 14 Setting Areas A & B with 4 Channel Receiver .............. 15 Installing a Smoke Detector ............................................. 16,17 Wired Panic Alarm ...........................................................18 Installing Panic Alarm ......................................................18 Add, Change, Delete User Numbers................................ 19 Installing a Smoke Detector .............................................19 Setting Zones to Stay Mode .............................................. 20 Chime Zones Settings........................................................ 20 Entry & Exit Delay Times ................................................ 20 Mobile Phone Setup........................................................... 21,28 Dialler Reporting Options ................................................ 21,28 Monitoring Station Setup.................................................. 28,31 Crow Wave 8 Basic Setup Diagram................................. 32

SENSOR WIRING FOR 1 ZONE INSTALLING 1 ZONE WITH 2.2K RESISTORS


tamper 4&8

2&6

3&7

1&5

GND

4&8

GND

12 V

2.2K RESISTORS A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

Zone 1

SENSOR WIRING FOR 2 ZONES INSTALLING 2 ZONES WITH 2.2K RESISTORS

1&5

GND

tamper

2&6

3&7

GND

12 V

2.2K RESISTORS A B C D E F ALARM ALARM 12 V 0V TAMP TAMP A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

Zone 1

Zone 2 4

GND 12 V

12 V

GND 12 V

12 V

SENSOR WIRING FOR 3 ZONES INSTALLING 3 ZONES WITH 2.2K RESISTORS

GND

1&5

tamper 4&8

2&6

3&7

4&8

GND

12 V

2.2K RESISTORS

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

Zone 1

Zone 2 2.2K RESISTORS

Zone 3

SENSOR WIRING FOR 4 ZONES INSTALLING 4 ZONES WITH 2.2K RESISTORS


tamper 2&6 3&7

1&5

GND

GND

12 V

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP Zone 4

Zone 1

Zone 2 2.2K RESISTORS 5

Zone 3 2.2K RESISTORS

GND 12 V

12 V

GND 12 V

12 V

SENSOR WIRING FOR 5 ZONES INSTALLING 5 ZONES WITH 2.2K RESISTORS

GND

1&5

tamper

2&6

3&7

4&8

GND

12 V

4.7k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP Zone 4

Zone 1

Zone 2

Zone 3 2.2K RESISTORS 2.2K RESISTORS

8.2k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

Zone 5

PROGRAMMING ZONE 5 INTO SYSTEM

Press Program button then installers number (000000) then Enter. You are now in programming mode. The program light will be flashing. Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1 then Enter (this turns zone 5 on) Press Program then 125 then enter. Then press 1 then Enter. 3 will flash, press 14 then 14 will flash back then Enter (this changes the resistors).

GND 12 V

12 V

SENSOR WIRING FOR 6 ZONES INSTALLING 6 ZONES WITH 2.2K RESISTORS

GND

1&5

tamper

2&6

3&7

4&8

GND

12 V

4.7k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

4.7k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP Zone 4

Zone 1

Zone 2

Zone 3 2.2K RESISTORS

8.2k

8.2k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

Zone 5 2.2K RESISTORS

Zone 6

PROGRAMMING ZONE 5 & 6 INTO SYSTEM


Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1 then Enter (this turns zone 5 on). Press Program then 122 then enter. Then press 6 then Enter. 7 will be lit up then press 1 then Enter (this turns zone 6 on). Press Program then 125 then enter. Then press 1 then Enter. 3 will be lit up then press 14 then 14 will flash back then Enter (this changes the resistors). Press Program then 125 then enter. Then press 2 then Enter. 3 will be lit up then press 14 then 14 will flash back then Enter (this changes the resistors).
7

GND 12 V

12 V

SENSOR WIRING FOR 7 ZONES INSTALLING 7 ZONES WITH 2.2K RESISTORS


tamper

2&6

3&7

GND

1&5

4&8

GND

12 V

4.7k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

4.7k 4.7k A B C D E F ALARM ALARM 12 V 0V TAMP TAMP A B C D E F ALARM ALARM 12 V 0V TAMP TAMP A B C D E F ALARM ALARM 12 V 0V TAMP TAMP Zone 4 2.2K RESISTORS

Zone 1

Zone 2

Zone 3

8.2k

8.2k

8.2k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP Zone 7

Zone 5

Zone 6

2.2K RESISTORS

PROGRAMMING ZONES 5, 6 & 7 INTO SYSTEM Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1 then Enter (this turns zone 5 on). Press Program then 122 then enter. Then press 6 then Enter. 7 will be lit up then press 1 then Enter (this turns zone 6 on). Press Program then 122 then enter. Then press 7 then Enter. 7 will be lit up then press 1 then Enter (this turns zone 7 on). Press Program then 125 then enter. Then press 1 then Enter. 3 will be lit up then press 14 then 14 will flash back then Enter (this changes the resistors). Press Program then 125 then enter. Then press 2 then Enter. 3 will be lit up then press 14 then 14 will flash back then Enter (this changes the resistors). Press Program then 125 then enter. Then press 3 then Enter. 3 will be lit up then press 14 then 14 will flash back then Enter (this changes the resistors). 8

GND 12 V

12 V

SENSOR WIRING FOR 8 ZONES INSTALLING 8 ZONES WITH 2.2K RESISTORS


GND 1&5 tamper 2&6 3&7 4&8 GND 12 V Zone 4 8.2k A B C D E F ALARM ALARM 12 V 0V TAMP TAMP Zone 8 12 V

GND

12 V

4.7k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

4.7k 4.7k A B C D E F ALARM ALARM 12 V 0V TAMP TAMP A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

4.7k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

Zone 1

Zone 2

Zone 3

8.2k

8.2k

8.2k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP Zone 7

Zone 5

Zone 6

2.2K RESISTORS

PROGRAMMING ZONES 5, 6, 7 & 8 INTO SYSTEM Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1 then Enter (this turns zone 5 on). Press Program then 122 then enter. Then press 6 then Enter. 7 will be lit up then press 1 then Enter (this turns zone 6 on). Press Program then 122 then enter. Then press 7 then Enter. 7 will be lit up then press 1 then Enter (this turns zone 7 on). Press Program then 122 then enter. Then press 8 then Enter. 7 will be lit up then press 1 then Enter (this turns zone 8 on). Press Program then 125 then enter. Then press 1 then Enter. 3 will be lit up then press 14 then 14 will flash back then Enter (this changes the resistors). Press Program then 125 then enter. Then press 2 then Enter. 3 will be lit up then press 14 then 14 will flash back then Enter (this changes the resistors). Press Program then 125 then enter. Then press 3 then Enter. 3 will be lit up then press 14 then 14 will flash back then Enter (this changes the resistors). Press Program then 125 then enter. Then press 4 then Enter. 3 will be lit up then press 14 9 then 14 will flash back then Enter (this changes the resistors).

DOUBLE ZONE WIRING DIAGRAM


JOIN BLUE AND WHITE WIRE INSIDE THE PANEL

INSTALLING ZONES WITH 2.2K RESISTORS

1&5

GND

tamper White Wire Blue Wire 2.2k

2&6

3&7

4&8

GND

12 V

Blue Wire

White Wire Blue Wire

Join Wires Inside panel

Blue Wire White Wire

White Wire

4.7k

8.2k

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP Zone 5 10

Zone 1

GND 12 V

12 V

DOUBLE ZONE WIRING DIAGRAM


JOIN BLUE AND WHITE WIRE INSIDE THE PANEL DIFFERENT SENSOR WIRING AND REED SWITCH WIRING

INSTALLING ZONES WITH 2.2K RESISTORS

1&5

GND

tamper

2&6

3&7

4&8

GND

12 V

4.7k

4.7k

4.7k

GND 12 V

12 V

4.7k

0V 12 V TAMP TAMP ALARM ALARM

Zone 1

Zone 1

Zone 1

2.2k

8.2k

2.2k

8.2k

8.2k 2.2k

0V 12 V TAMP TAMP ALARM ALARM

TAMP TAMP 0V 12 V COM N/O

N/O COM 12 V 0V TAMP TAMP

Zone 5

Zone 5

Zone 5

REED SWITCH WIRING 4.7k COM N/C N/O COM 4.7k N/C N/O 12 VOLT SUPPLY FROM BOARD

Zone 1 2.2k 8.2k COM N/C N/O

Zone 1 8.2k 2.2k A B C D E F ALARM ALARM 12 V 0V TAMP TAMP Zone 5 11 Zone 5

TAMP TAMP ALARM ALARM 12 V 0V Zone 5

TAMP TAMP ALARM ALARM 12 V 0V Zone 1 8.2k

N/O COM 12 V

TAMP TAMP 0V 12 V COM N/O

0V TAMP TAMP

ADDING A TRANSMITTER (75-063) & SINGLE CHANNEL RECEIVER (75-067) Enter into programming mode Installers code (000000) set by default

Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. Press Program then 111 then Enter. Then press 1 then Enter. Press 1 so it lights up. Then Enter. SETTING STROBE TO FLASH (This will set the strobe to flash when the alarm is armed / disarmed) Press Program then 54 then Enter. Then press 1 then Enter. Press 2 so it lights up. Then Enter. Press Program then 56 then Enter. Then press 1 then Enter. Press 2 so it lights up. Then Enter. Press program then 39 then Enter. Then 2 then Enter. Then time in seconds (ie 20 = 2 seconds) then Enter. Exit Program mode. Press Program then Enter. SETTINGS FOR SINGLE CHANNEL RECEIVER 75-067 Set for one second Cut LP 2 Dont cut LP 1
EARTH LIN DAT CLK NEG tamper 2&6 3&7 4&8

Crow Alarm Panel

IN AC

GND

12 V

1&5

GND

12 V

GND 12 V 2.2k resistor Already In system

POS 1 2

4.7k resistor

75-067 Single Channel Receiver Alarm panel Tamper switch Normally closed 12

N/O

N/C com +

ADDING A TRANSMITTER (75-063) & 4 CHANNEL RECEIVER (75-064) Enter into programming mode Installers code (000000) set by default

Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. Press Program then 111 then Enter. Then press 1 then Enter. Press 1 so it lights up. Then Enter.

SETTING STROBE TO FLASH Press Program then 54 then Enter. Then press 1 then Enter. Press 2 so it lights up. Then Enter. Press Program then 56 then Enter. Then press 1 then Enter. Press 2 so it lights up. Then Enter. Press program then 39 then Enter. Then 2 then Enter. then time in seconds (ie 20 = 2 seconds) then Enter. Exit Program mode. Press Program then Enter.

EARTH LIN DAT CLK NEG tamper 2&6 3&7 4&8 GND GND 12 V 1&5 12 V GND 12 V POS 1 2 C C

Crow Alarm Panel

IN AC

2.2k resistor Already In system

4.7k resistor

COM

COM

COM

COM

N/O

N/O

N/O

N/O

N/C

N/C

N/C

N/C

CH 4

CH 3

CH 2 75-064 4 CHANNEL RECEIVER

CH 1

+ 12v Pwr In

Alarm panel Tamper switch Normally closed 13

AWAY (ARM / DISARM) AND STAY MODE USING TRANSMITTER & 4 CHANNEL RECEIVER (75-064) Enter into programming mode Installers code (000000) set by default

Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. Press Program then 111 then Enter. Then press 1 then Enter. Press 1 so it lights up. Then Enter. Press Program then 111 then Enter. Then press 2 then Enter. Press 1 so it lights up. Then Enter. Press Program then 112 then Enter. Then press 2 then Enter. Press 1,3 so the lights go off and then press 2,4 so they light up. Then Enter. SETTING STROBE TO FLASH Press Program then 54 then Enter. Then press 1 then Enter. Press 2 so it lights up. Then Enter. Press Program then 56 then Enter. Then press 1 then Enter. Press 2 so it lights up. Then Enter. Press program then 39 then Enter. Then 2 then Enter. then time in sec then Enter Exit Program mode. Press Program then Enter.

EARTH LIN DAT CLK NEG tamper 2&6 3&7 4&8 GND GND 12 V 1&5 12 V GND 12 V 2.2k resistor Already In system + 12v Pwr In POS 1 2 C C

Crow Alarm Panel

IN AC

4.7k resistor 8.2k resistor

COM

COM

COM

COM

N/O

N/O

N/O

CH 4

CH 3

CH 2 75-064 4 CHANNEL RECEIVER

CH 1

Alarm panel Tamper switch Normally closed 14

N/O

N/C

N/C

N/C

N/C

AREAS A and B USING TRANSMITTER & 4 CHANNEL RECEIVER (75-064) Enter into programming mode Installers code (000000) set by default

Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. Press Program then 111 then Enter. Then press 1 then Enter. Press 1 so it lights up. Then Enter. Press Program then 111 then Enter. Then press 2 then Enter. Press 2 so it lights up. Then Enter.

. SETTING STROBE TO FLASH Press Program then 54 then Enter. Then press 1 then Enter. Press 2 so it lights up. Then Enter. Press Program then 56 then Enter. Then press 1 then Enter. Press 2 so it lights up. Then Enter. Press program then 39 then Enter. Then 2 then Enter. then time in sec then Enter Exit Program mode. Press Program then Enter.

EARTH LIN DAT CLK NEG tamper 2&6 3&7 4&8 GND GND 12 V 1&5 12 V GND 12 V 2.2k resistor Already In system + 12v Pwr In POS 1 2 C C

Crow Alarm Panel

IN AC

4.7k resistor 8.2k resistor

COM

COM

COM

COM

N/O

N/O

N/O

CH 4

CH 3

CH 2 75-064 4 CHANNEL RECEIVER

CH 1

Alarm panel Tamper switch Normally closed 15

N/O

N/C

N/C

N/C

N/C

ADDING SMOKE DETECTOR TO ZONE Enter into programming mode Installers code (000000) set by default Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. Press Program then 122 then Enter. Select the zone you wish to use, As Normally open. Then Enter. 1,6,7 will be lit up. press 6,7,2 No 2 will light up and 6,7 will go out. Then Enter. Press Program then 123 then Enter. Select the same number zone as above. (The zone you made normally open ) Then Enter. Press number 5 then enter. This will set zone as fire zone. Exit Program mode. Press Program then Enter.

Diagram 1

Crow Alarm Panel Set up for zone 4


When Zones 5 to 8 not used tamper GND 12 V

2.2k resistor
ZONE 4 12 V OV

Address Program 122, location zone 4,select No 2. Enter Address Program 123, location zone 4,Select No 5. Enter

Latching smoke detector Normally open

Diagram 2

Crow Alarm Panel

Set up for zone 2


When Zones 5 to 8 not used

tamper GND 12 V

2.2k resistor
ZONE 2 12 V OV

Address Program 122, location zone 2,select No 2. Enter Address Program 123, location zone 2,Select No 5. Enter

Latching smoke detector Normally open

16

ADDING SMOKE DETECTOR TO ZONE WHEN USING MORE THAN EIGHT ZONES Enter into programming mode Installers code (000000) set by default Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. Press Program then 122 then Enter. Press 8 then Enter. 7 Will be lit up. Press 7,2,1 numbers 2 and 1 will light up and 7 will go out. Then Enter Zones1 to 4 need a 4.7 resistor across the contacts. Zones 5 to 8 need a 8.2k resistor across the contacts. As per Diagram 1 Press Program then 123 then Enter. Press 8 then Enter. Press 5 so it lights up then Enter. This will set zone as fire zone. Press Program then 125 then enter. Then press 4 then Enter. 3 will flash then press 14 then 14 will flash back then Enter. Exit Program mode. Press Program then Enter.

Diagram 1

Crow Alarm Panel

Set up for zone 8


When Zones are being doubled

tamper GND 12 V

8.2k resistor
ZONE 8

12 V OV

4.7k

2.2k resistor

Latching smoke detector Normally open

A B C D E F ALARM ALARM 12 V 0V TAMP TAMP

Address Program 122, location zone 8,select Nos 1 & 2. Enter Address Program 123, location zone 8,Select No 5. Enter Address Program 125, location zone 4,Select No 14. Enter

17

ADDING PANIC BUTTON TO ZONE Enter into programming mode Installers code (000000) set by default Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. Press Program then 122 then Enter. Select the zone you wish to use, As Normally open. Then Enter. Numbers 1,6,7 will be lit up. Press 6,7,2 number 2 will light up and 6,7 will go out. Then Enter. Zones1 to 8 need a 2.2k resistor across the contacts. Press Program then 123 then Enter. Select the same number zone as above. Then Enter Press 3 then Enter. This will set zone as 24 hour zone. Exit Program mode. Press Program then Enter. As per Diagram 1

Diagram 1

Crow Alarm Panel

Set up for zone 4


Address Program 122, location zone 4 select No 2 & 6 & 7 . 2 will light up 7 & 6 will go out then Enter. Address Program 123, location zone 4 Select No 3 then Enter

Panic Button Normally open

ZONE 4

Diagram 2

tamper GND 12 V

OV

OV

2.2k resistor

Crow Alarm Panel

Set up for zone 8


When Zones 4 is being used as a zone

Address Program 122, location zone 8 select No1 & 2 then Enter Address Program 123, location zone 8 Select No 3 then Enter Address Program 125, location zone 4,select No 14. Enter

OV

OV

tamper GND 12 V

Panic Button Normally open

8.2k resistor
Zone 8 18

ALARM ALARM 12 V 0V TAMP TAMP

4.7k resistor 2.2k resistor

Zone 4

A B C D E F

PIN NUMBER CHANGING ADD / CHANGE / DELETE USER NUMBERS There is a Maximum 100 Users Enter into programming mode Installers code (000000) set by default Press Program button then installers number (000000) then Enter. You are now in programming mode. Program light will be flashing. User 1 Press Program then 1 then Enter, Then 1 then Enter. Then user number (1 to 6 Digits in Length) then Enter. ( 123 is default ) User 1 is Master Code which can be used to change Codes, Clock, and Phone Nos
ADDRESS USER 1 USER 2 USER 3 USER 4 USER 5 USER 6 USER 7 USER 8 USER 9 1 1 1 1 1 1 1 1 1 USER No 1 2 3 4 5 6 7 8 9 User codes can be between 1 and 6 digits in length NUMBER 123 Default

User 2 Press Program then 1 then Enter. Then 2 then Enter. Then user number (1 to 6 Digits) then Enter. User 3 Press Program then 1 then Enter. Then 3 then Enter. Then user number (1 to 6 Digits) then Enter. Users 4 to 100 can be added by following the steps above CHANGE INSTALLERS NUMBER Press Program then 25 then Enter. Then 1 then Enter. Enter installer number (3 to 6 digits in Length) then Enter. (000000) default. Delete User Number (LED KEYPAD) Press Program then the user number location you want to delete (2 to 100) then Enter, then Bypass then Enter. Delete User Number (LCD KEYPAD) Press Program then 1 Then Enter. Then the user number location you want to delete (2 to 100) then Enter, then Control then 0 then Enter. Defaulting System Press Program then 200 then Enter. Then 10 then Enter. Defaulting System numbers Press Program then 200 then Enter. Then 9 then Enter. ( pin numbers & phone numbers)
19

SETTING THE CLOCK Press Program then 26 then Enter then 1 then Enter then the time (24 hour time) then Enter. Press Program then 26 then Enter then 2 then Enter. Then the day 1=Sun, 2=Mon, 3=Tue, 4=Wed, 5=Thu, 6=Fri, 7=Sat, then Enter. Press Program then 26 then Enter then 3 then Enter. Then the date (day / month / year) DD/MM/YY ENTRY & EXIT DELAY TIMES Zone 1 is Set to entry and exit ( Default setting 20 seconds entry / 60 seconds exit.) Change Entry Times ( Zone 1) Press program then 144 then Enter. Then 1 then Enter. Then the time in seconds (0-9999) then Enter. Change Entry Times ( Zone 2) Press program then 144 then Enter. Then 2 then Enter. Then the time in seconds (0-9999) then Enter. Change Entry Times ( Zone 3) Press program then 144 then Enter. Then 3 then Enter. Then the time in seconds (0-9999) then Enter. To change any other zone entry time, follow steps above Zones 2 to 8 Are Set To 0 Seconds for instance. Change Exit Times Press Program then 60 then Enter. then 1 then Enter then the time in seconds (0-255) then Enter. Default Set for 60 Seconds EXTRA SETTINGS Setting Zones For Stay Mode (1 to 4 are on by default) Press Program then 122 then Enter. Then Press the zones you want in stay mode (4 To 8) then Enter. Then press number 6 so it lights up then press Enter. Setting Zones To Chime Zone (Disarmed) Press Program then 123 then Enter, Then press the zones to be chime zones then Enter. Then press 7 so it lights up then Enter. Wired Panic Alarm Press Program then 122 then Enter. Then press the zone number you are using for this type of alarm then Enter 1,6,7 will be light up press 6,7,2 number will light up 6,7 will go out then Enter. Press Program then 123 then Enter. Then press the zone number you are using for this alarm then Enter press 3 then Enter. (this will set for 24 hour zone). Exit programming mode. Press Program then Enter.

20

MOBILE PHONE SETUP


Turn Dialler On Press Program then 175 then Enter, Then press 1 then Enter. numbers 2,6,7, should be lit up, Press 7 so it goes out. Press 1 so it lights up Then press Enter (Turns on dialler). Press Program then 175 then Enter, Then press 5 then Enter. 168 will flash. Press 0 then Enter.
( NOTE : The settings below will allow the alarm to call your mobile once and if not answered to move on to next stored number )

FIRST PHONE NUMBER

Entering Phone Numbers First Number Press Program then 181 then Enter. Then Enter 1 Then Enter. Then press Phone Number (Up to 16 Digits) then Enter. Press Program then 182 then Enter. Then press 1 then Enter. 1will flash on .Then press 2 then Enter. Press Program then 183 then Enter. Then press 1 then Enter. 1,2,4 will be light up Then press ,4 then Enter.(1,2, will light up and 4, will go out) Press Program then 184 then Enter. Then press 1 then Enter, 3 will flash . Press 1 and then press Enter Press Program then 186 then Enter. Then press 1 then Enter, 1 = Report Mains Fail (Turn Off) 2 = Report Low Battery (Turn Off) 3 = Report Radio battery low (Turn Off) 4 = Report Line Failure (Turn Off) 5 = Report System Tamper (Leave On) 6 = Report keypad Tamper (Turn Off) 7 = Report Zone Tamper (Turn Off) 8 = Report Radio Tamper (Turn Off) Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter. Note: You Can Not Turn Off The Alarm Activity Reporting. Press Program then 187 then Enter. Then press 1 then Enter, 1 = Report Duress Alarm 2 = Report Radio Alarm 3 = Report Sensor Watch 4 = Report Panic Alarm 5 = Report Fire Alarm 6 = Report Medical Alarm 7 = Report Pendant Alarm 8 = Report Zone Bypasses

(Turn Off) (Turn Off) (Turn Off) (Turn Off) (Leave On) (Turn Off) (Turn Off) (Turn Off)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter
21

MOBILE PHONE SETUP

FIRST PHONE NUMBER CONTINUED

Press Program then 188 then Enter. Then 1 then Enter 1 = Report Arm/Disarm (Turn Off) 2 = Report Stay mode arm (Turn Off) 3 = Report Disarm activation (Turn Off) 4 = Report Stay activation (Turn Off) 5 = Report Stay mode (Turn Off) 6 = Report Program mode (Leave Off) 7 = Report 24 hours (Leave On) 8 = Report restores (Turn Off) Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter.

Note: You Can Not Turn Off The Alarm Activity Reporting. Press Program then 189 then Enter. Then press 1 then Enter, 1 = Report latchkey 2 = Report delinquent 3 = Report tests 4 = Report fuse failure 5 = Report output fail 6 = Report time change 7 = Report keypad trouble 8 = Report Zone rf jamming

(Leave Off) (Leave Off) (Turn Off) (Turn Off) (Turn Off) (Leave Off) (Leave Off) (Leave Off)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter

22

MOBILE PHONE SETUP


SECOND PHONE NUMBER

Entering Phone Numbers Second Number Press Program then 181 then Enter. Then Enter 2 Then Enter. Then press Phone Number (Up to 16 Digits) then Enter. Press Program then 182 then Enter. Then press 2 then Enter. 1 will flash on .Then press 2 then Enter. Press Program then 183 then Enter. Then press 2 then Enter. 1,2,4 will be lit up Then press 4 then Enter. (1,2, will light up and 4, will go out). Press Program then 184 then Enter. Then press 2 then Enter, 3 will flash . Press 1 and then press Enter.

Press Program then 186 then Enter. Then press 2 then Enter. 1 = Report Mains Fail (Turn Off) 2 = Report Low Battery (Turn Off) 3 = Report Radio battery low (Turn Off) 4 = Report Line Failure (Turn Off) 5 = Report System Tamper (Leave On) 6 = Report keypad Tamper (Turn Off) 7 = Report Zone Tamper (Turn Off) 8 = Report Radio Tamper (Turn Off) Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter. Note: You Can Not Turn Off The Alarm Activity Reporting. Press Program then 187 then Enter. Then press 2 then Enter, 1 = Report Duress Alarm 2 = Report Radio Alarm 3 = Report Sensor Watch 4 = Report Panic Alarm 5 = Report Fire Alarm 6 = Report Medical Alarm 7 = Report Pendant Alarm 8 = Report Zone Bypasses

(Turn Off) (Turn Off) (Turn Off) (Turn Off) (Leave On) (Turn Off) (Turn Off) (Turn Off)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter

23

MOBILE PHONE SETUP


SECOND PHONE NUMBER CONTINUED

Press Program then 188 then Enter. Then 2 then Enter 1 = Report Arm/Disarm (Turn Off) 2 = Report Stay mode arm (Turn Off) 3 = Report Disarm activation (Turn Off) 4 = Report Stay activation (Turn Off) 5 = Report Stay mode (Turn Off) 6 = Report Program mode (Leave Off) 7 = Report 24 hours (Leave On) 8 = Report restores (Turn Off) Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter. Note: You Can Not Turn Off The Alarm Activity Reporting. Press Program then 189 then Enter. Then press 2 then Enter. 1 = Report latchkey 2 = Report delinquent 3 = Report tests 4 = Report fuse failure 5 = Report output fail 6 = Report time change 7 = Report keypad trouble 8 = Report Zone jamming

(Leave Off) (Leave Off) (Turn Off) (Turn Off) (Turn Off) (Leave Off) (Leave Off) (Leave Off)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter

24

MOBILE PHONE SETUP


THIRD PHONE NUMBER

Entering Phone Numbers Third Number Press Program then 181 then Enter. Then Enter 3 Then Enter. Then press Phone Number (Up to 16 Digits) then Enter. Press Program then 182 then Enter. Then press 3 then Enter. 1will flash on .Then press 2 then Enter. Press Program then 183 then Enter. Then press 3 then Enter. 1,2,4 will be lit up Then press 4 then Enter. (1,2, will light up and 4, will go out). Press Program then 184 then Enter. Then press 3 then Enter, 3 will flash . Press 1 and then press Enter.

Press Program then 186 then Enter. Then press 3 then Enter, 1 = Report Mains Fail (Turn Off) 2 = Report Low Battery (Turn Off) 3 = Report Radio battery low (Turn Off) 4 = Report Line Failure (Turn Off) 5 = Report System Tamper (Leave On) 6 = Report keypad Tamper (Turn Off) 7 = Report Zone Tamper (Turn Off) 8 = Report Radio Tamper (Turn Off) Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter. Note: You Can Not Turn Off The Alarm Activity Reporting. Press Program then 187 then Enter. Then press 3 then Enter, 1 = Report Duress Alarm 2 = Report Radio Alarm 3 = Report Sensor Watch 4 = Report Panic Alarm 5 = Report Fire Alarm 6 = Report Medical Alarm 7 = Report Pendant Alarm 8 = Report Zone Bypasses

(Turn Off) (Turn Off) (Turn Off) (Turn Off) (Leave On) (Turn Off) (Turn Off) (Turn Off)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter

25

MOBILE PHONE SETUP


THIRD PHONE NUMBER CONTINUED

Press Program then 188 then Enter. Then 3 then Enter 1 = Report Arm/Disarm (Turn Off) 2 = Report Stay mode arm (Turn Off) 3 = Report Disarm activation (Turn Off) 4 = Report Stay activation (Turn Off) 5 = Report Stay mode (Turn Off) 6 = Report Program mode (Leave Off) 7 = Report 24 hours (Leave On) 8 = Report restores (Turn Off) Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter. Note: You Can Not Turn Off The Alarm Activity Reporting. Press Program then 189 then Enter. Then press 3 then Enter, 1 = Report latchkey 2 = Report delinquent 3 = Report tests 4 = Report fuse failure 5 = Report output fail 6 = Report time change 7 = Report keypad trouble 8 = Report Zone jamming

(Leave Off) (Leave Off) (Turn Off) (Turn Off) (Turn Off) (Leave Off) (Leave Off) (Leave Off)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter

26

MOBILE PHONE SETUP


FOURTH PHONE NUMBER

Entering Phone Numbers Fourth Number Press Program then 181 then Enter. Then Enter 4 Then Enter. Then press Phone Number (Up to 16 Digits) then Enter. Press Program then 182 then Enter. Then press 4 then Enter. 1will flash on .Then press 2 then Enter. Press Program then 183 then Enter. Then press 4 then Enter. 1,2,4 will be lit up Then press 4 then Enter. (1,2, will light up and 4, will go out). Press Program then 184 then Enter. Then press 4 then Enter, 3 will flash . Press 1 and then press Enter.

Press Program then 186 then Enter. Then press 4 then Enter. 1 = Report Mains Fail (Turn Off) 2 = Report Low Battery (Turn Off) 3 = Report Radio battery low (Turn Off) 4 = Report Line Failure (Turn Off) 5 = Report System Tamper (Leave On) 6 = Report keypad Tamper (Turn Off) 7 = Report Zone Tamper (Turn Off) 8 = Report Radio Tamper (Turn Off) Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter. Note: You Can Not Turn Off The Alarm Activity Reporting. Press Program then 187 then Enter. Then press 4 then Enter. 1 = Report Duress Alarm 2 = Report Radio Alarm 3 = Report Sensor Watch 4 = Report Panic Alarm 5 = Report Fire Alarm 6 = Report Medical Alarm 7 = Report Pendant Alarm 8 = Report Zone Bypasses

(Turn Off) (Turn Off) (Turn Off) (Turn Off) (Leave On) (Turn Off) (Turn Off) (Turn Off)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter.

27

MOBILE PHONE SETUP


FOURTH PHONE NUMBER CONTINUED

Press Program then 188 then Enter. Then 4 then Enter 1 = Report Arm/Disarm (Turn Off) 2 = Report Stay mode arm (Turn Off) 3 = Report Disarm activation (Turn Off) 4 = Report Stay activation (Turn Off) 5 = Report Stay mode (Turn Off) 6 = Report Program mode (Leave Off) 7 = Report 24 hours (Leave On) 8 = Report restores (Turn Off) Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter. Note: You Can Not Turn Off The Alarm Activity Reporting. Press Program then 189 then Enter. Then press 4 then Enter, 1 = Report latchkey 2 = Report delinquent 3 = Report tests 4 = Report fuse failure 5 = Report output fail 6 = Report time change 7 = Report keypad trouble 8 = Report Zone rf jamming

(Leave Off) (Leave Off) (Turn Off) (Turn Off) (Turn Off) (Leave Off) (Leave Off) (Leave Off)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter

28

MONITORING

STATION

SET UP

Press Program then 175 then Enter, Then press 1 then Enter. Numbers 2,6,7, are lit up. Press 1 so it lights up. Then press Enter (Turns on dialler). Test call time of the day: Press Program then 175 then Enter, Then press 4 then Enter. Enter the time of the day to send the call in 24 hour time HH.MM (0430 the time is set by default). Test call day times: Press Program then 175 then Enter, Then press 5 then Enter. 1,6,8 will flash . Press 24 (every24 hours it will send a test call) Then Enter. (168 set by default: once a week) Monitoring account code: Press Program then 62 then Enter. Then press 1 then Enter. Then Enter the account number then Enter. (Account number from the monitoring company). Entering Phone Numbers Primary Number Press Program then 181 then Enter. Then Enter 1 Then Enter. Then press Phone Number (Up to 16 Digits) then Enter. Press Program then 184 then Enter. Then press 1 then Enter, Number 3 will flash . Then Press 6 then press Enter. Check with monitoring company on what they want on Press Program then 186 then Enter. Then 1 then Enter. 1 = Report Mains Failure 2 = Report Low battery 3 = Report Wireless Battery 4 = Report Line Failure 5 = Report System Tamper 6 = Report Key pad Tam 7 = Report Zone Tamper 8 = Report Radio Tamper Press Program then 187 then Enter. Then 1 then Enter. 1 = Report Duress Alarm 2 = Report Radio 3 = Report Sensor watch 4 = Report panic 5 = Report Fire 6 = Report Medical 7 = Report Radio Panic 8 = Zone bypasses

(Leave On) (Leave On) (Leave On) (Leave On) (Leave On) (Leave On) (Leave On) (Leave On)

(Leave On) (Leave On) (Leave On) (Leave On) (Leave On) (Leave On) (Leave On) (Leave On)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter.

29

MONITORING

STATION

SET UP

CONTINUED

Press Program then 188 then Enter. Then 1 then Enter 1 = Report Open / Close 2 = Report Stay Open / Close 3 = Report Open after Alarm 4 = Report Stay Open after Alarm 5 = Report Alarm in Stay 6 = Report Access programming 7 = Report 24 hr alarm 8 = Report Restores

(Turn Off) (Turn Off) (Turn Off) (Turn Off) (Turn Off) (Leave Off) (leave On) (Leave On)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter. Press Program then 189 then Enter. 1 = Report latch 2 = Report Delinquent 3 = Report Tests 4 = Report Fuse Failure 5 = Report output fails

(Turn Off) (Turn Off) (Leave On) (Leave On) (Leave On)

Check With Your Monitoring Station What They Need On. Refer to Page 41-42 of the Technicians Handbook Exit Programming Mode Press Program then Enter.

30

BACK UP NUMBER Press Program then 181 then Enter. Then Enter 2 Then Enter. Then press Phone Number (Up to 16 Digits) then Enter. Press Program then 184 then Enter. Then press 2 then Enter, Number 3 will flash . Then Press 6 then press Enter Enter the same as the primary number Press Program then 186 then Enter. Then 1 then Enter. 1 = Report Mains Failure 2 = Report Low battery 3 = Report Wireless Battery 4 = Report Line Failure 5 = Report System Tamper 6 = Report Key pad Tam 7 = Report Zone Tamper 8 = Report Radio Tamper

(Leave On) (Leave On) (Leave On) (Leave On) (Leave On) (Leave On) (Leave On) (Leave On)

Press Program then 187 then Enter. Then 1 then Enter. 1 = Report Duress Alarm (Leave On) 2 = Report Radio (Leave On) 3 = Report Sensor watch (Leave On) 4 = Report panic (Leave On) 5 = Report Fire (Leave On) 6 = Report Medical (Leave On) 7 = Report Radio Panic (Leave On) 8 = Zone bypasses (Leave On) Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter. Press Program then 188 then Enter. Then 1 then Enter 1 = Report Open / Close 2 = Report Stay Open / Close 3 = Report Open after Alarm 4 = Report Stay Open after Alarm 5 = Report Alarm in Stay 6 = Report Access programming 7 = Report 24 hr alarm 8 = Report Restores

(Turn Off) (Turn Off) (Turn Off) (Turn Off) (Turn Off) (Leave Off) (leave On) (Leave On)

Press the numbers that you want Off so the lights are Out. The lights that are On are the only reports that you will get. Then press Enter. Press Program then 189 then Enter. 1 = Report latch 2 = Report Delinquent 3 = Report Tests 4 = Report Fuse Failure 5 = Report output fails Check With Your Monitoring Station What They Need On. Refer to Page 41-42 of the Technicians handbook. Exit Programming Mode Press Program then Enter.
31

(Turn Off) (Turn Off) (Leave On) (Leave On) (Leave On)

EARTH LIN DAT CLK NEG tamper 12 V 2&6 3&7 4&8 GND 12 V 1&5 GND 12 V GND POS 1 2 C C

Crow Runner Alarm Panel

IN AC

16 VOLT Power Supply

Indoor Siren Black to Output 1

In Door Siren Red to 12 Volt

ALARM ALARM 12 V 0V TAMP TAMP PIR No 1

32

Power Brown To 12 volt 2.2 K RESISTOR Siren Red to Output 1

Strobe White To Output 2 4.7k

2.2k

Key Pad Runner

A B C D E F