From the inception of the design, Hager have worked closely with contractors and developers, to accommodate the homeowner with products that not only provide safety and peace of mind, but that are easy to use and good to look at.
RCCB protection (will disconnect the protected circuits whenever it detects current leaking out of the circuit)
Easy Access
Removable and re-sealable top wall (re-sealable to IP4X with foam strips provided)
accessories
The New Hager Consumer Unit has been designed to be the most versatile consumer unit available on the market today. The accessories below can be used to customise standard consumer units and enclosures to almost any configuration. I 1 module blank piece I 8 module busbar I 12 module busbar I 22 module busbar I Neutral link I Locking kit I Incoming tail connection kit
incomer variants
I Switch disconnector; 63 & 100A I RCCB; 40A 30mA, 63A 30mA, 100A 30mA I Split load; 100A Switch disconnector, 63A/80A/100A RCCB I Split load time delayed; 100mA time delayed RCCB 63A 30mA RCCB I Split load twin RCCB; 100A switch disconnector + 2 x RCCB I Twin tariff; 2 x 100A switch disconnector I Multi tariff; 2 x 100A 1 x 63A switch disconnectors
IP ratings
Metal: IP3X with door closed Insulated: IP3X door closed and insulated top wall (IP4X top wall only) IP2XC with door open, and full complement of devices / blanks fitted The classification for the service condition, where all external cable entries are satisfactorily sealed to prevent insertion of a rigid steel rod of 2.5mm diameter in accordance with BS EN 60529
performance characteristics
I Limits of operation: Ue = 240V, a.c. Ui = 300V, a.c. In = 63A (max) outgoing, rated frequency: 50Hz, Icc = conditional prospective short circuit 16kA at 240V, 50Hz, Pf 0.6. Classification: Environment B Maximum outgoing circuit = 63A 1P MCB/45A RCBO Protection of persons: indirect contact via protective circuit (metal enclosure), direct contact enclosure I Pollution degree 2 (with Hager outgoing devices installed) I Suitable for indoors use only I Suitable for the following earthing systems = TN-S, TT, TNC-S. I For dimensional information and weights please consult the manufacturers catalogue I All connections are classified as - Type F I Please consult Hager for applications where this consumer unit will be flush mounted in a hollow / cavity wall
telephone
National Technical Support Hotline 0870 607 6677 National Sales Hotline 0870 240 2400 National Sales Faxline 0870 240 0400