Load sharing 24 VDC backup supply connections Dynamic brake module RFI filter to meet CE directives
Contents
D2 Overview and Features D 14 Performance Data D 28 General Technical Data D 32 Dimensions D 44 Options D 68 Ordering Information VLT 5000 APU Program D 69 Overview D 70 NEMA 1/12 Bypass Package D 73 NEMA 1 Integrated APUs D 75 Ordering Information D2 www.namc.danfoss.com 1.800.432.6367
MOTION CONTROLS
IND.MC.12.15.01
Applications
Constant Torque Conveyors Palletizers Centrifuges Sequencing Positioning Synchronizing Pumps Tooling Machines Hoists Grinders
VLT 5000
New Display/Keypad
Removable Local Control Panel (LCP) allows downloading of program from drive to drive Displays multiple setup parameters Quick menu setup for easy commissioning Easy remote mounting of LCP
Enhanced Software
Automatic motor adaptation Built-in PID control Multiple data menu sets for quick system changeover Open or closed loop motor thermal protection Closed loop speed control available standard
Protection Features
Self-testing Overvoltage Overcurrent Undervoltage Overload Overheating External fault Electronic thermal Ground fault
Options
Remote keypad kit Din rail adaptor kit Brake resistors EMC filters Floor mounting kits (125-500 HP)
International Approvals
UL cUL CE
www.namc.danfoss.com
1.800.432.6367
D3
Drives Solutions
IND.MC.12.15.01
MOTION CONTROLS
D4
www.namc.danfoss.com
1.800.432.6367
IND.MC.12.15.01
The + and - keys are used to scroll and select the data values. For example, in the Language set-up menu (above), the + and - keys scroll through the choices of nine languages. Once the desired language is selected, pressing the Menu key stores the data value. The optional LCP-2 Keypad/Display provides all the features and performance benefits of the VLT 5000 Series LCP, and is also interchangeable with the VLT 2800 Series drives.
www.namc.danfoss.com
1.800.432.6367
D5
Drives Solutions
IND.MC.12.15.01
Advantages of VVCPLUS
Up to 160% torque for up to 1 minute Up to 180% starting breakaway torque (0.5 sec.) Up to 100% acceleration torque of rated torque Accurate slip compensation Full torque (up to 100%) down to 0 rpm in open loop control Full holding torque (up to 100%) at 0 rpm in closed loop control Fast compensation for speed variations with load changes High speed stability High resolution of output frequency Fast system response of 3 ms (1 ms) No motor derating Maximum stability during load changes
Oscilloscope trace of a motor phase current provided by a conventional pulse width modulation system with harmonic elimination (left); a Danfoss VVCPLUS system (right).
First and foremost, the current measurement and the motor model have been improved. The current is split into magnetizing and torque-generating parts and provides for more accurate and quicker estimation of the actual motor loads. It is now possible to compensate for rapid load changes. Full torque as well as extremely accurate speed control can now be attained at low speeds or even at standstill. In a special motor mode, permanent magnet synchronous motors and/or parallel motors can be used. Compared with a standard voltage/frequency control, VVCPLUS offers improved dynamics and stability, both when the speed reference and the load torque are changed. In addition, we have implemented a fully digitalized protection concept, which insures reliable operation even under the worst possible operating conditions. Naturally, the VLT 5000 Series also offers full protection against faulty coupling, short-circuiting, ground fault and overload. Danfoss drives with the VVCPLUS control system tolerate shock loads throughout their speed range and react swiftly to changes in reference. MOTION CONTROLS D6
www.namc.danfoss.com
1.800.432.6367
IND.MC.12.15.01
Menu Mode
Setup 1 2 Group Description 0 1 2 3 4 5 6 Operation and Display Load and Motor References and Limits Inputs and Outputs Special Functions Serial Communication Technical Functions Parameters 000-099 100-199 200-299 300-399 400-499 500-599 600-699 3 4
www.namc.danfoss.com
1.800.432.6367
D7
Drives Solutions
IND.MC.12.15.01
VLT 5000 Series has Built-in Protection to Maximize System Reliability Against:
System overloads Motor failures Heat Voltage disturbances Power surges Loss of phase Phase-to-phase and phase-to-ground short circuit Ground fault Switching on input/output Electrical disturbances
MOTION CONTROLS
D8
www.namc.danfoss.com
1.800.432.6367
IND.MC.12.15.01
VVC
PLUS
Unique digital VVCPLUS voltage vector control provides: Nearly perfect output sine wave Fully rated motor voltage at rated frequency High efficiency for both drive and motor Full motor performance without derating
Output Protection
VLT 5000 Series drives incorporate both DC-link filters and motor output protection as standard design features. This provides short circuit protection and allows unlimited switching on the output without damage to the drive, eliminating the need for additional output reactors or switch interlocks. The DC-link filter improves overall efficiency by increasing the power factor and lowering the ripple current in the bus voltage for an almost threefold increase in capacitor and drive life. As a result, motor operation is smooth and quiet and longer motor life can be expected.
VLT 5000
www.namc.danfoss.com
1.800.432.6367
D9
Drives Solutions
IND.MC.12.15.01
NEW!
350 to 550 HP 380-500 VAC
NEW!
40 to 350 HP 525-690 VAC
The new high power VLT 5000 Series drives are available in Chassis, NEMA 1 and NEMA 12 enclosures.
Enclosure VLT 5000 Style Model Chassis (IP00) 5032-5052 5122-5552 5042-5352 Protected Chassis (IP20) 5001-5027 5001-5102 5001-5032 NEMA 1 (IP21) 5001-5027 5032-5102 5001-5552 5001-5032 5042-5352 NEMA 12 (IP54) 5001-5027 5032-5052 5001-5552 5042-5352
VAC Class 230 460 690 230 460 575 230 230 460 575 690 230 230 460 690
Material Steel Steel Steel Aluminum Aluminum Aluminum Aluminum Steel Aluminum Aluminum Aluminum Aluminum Steel Aluminum Aluminum
Conformal Coating
Some applications require the drive to be operated in environments with airborne contaminants, such as wastewater treatment plants and paper pulp plants where corrosive gasses are present. These corrosive gases attack components in the drive; in particular, printed circuit assemblies and their components. High humidity and high ambient temperatures exacerbate the situation. Conformal coating is used to mitigate these corrosive effects. Danfoss has chosen a protective polyurethane coating that has good resistance to chemicals and fungus and meets UL requirements for use in electronic controls. Performance of the coating has been verified by independent laboratory testing of VLT 5000 Series using
Mounting
All VLT 5000 drives provide for a vertical wall-mounting arrangement. Most VLT 5000 Series drives allow for sideby-side mounting with zero side clearances.
Humidity
The VLT 5000 Series has been designed to meet the IEC 68-2-3 standard, EN 50178 pkt. 9.4.2.2/DIN 40040, class E, at 40C. See Specifications section for further information. MOTION CONTROLS
D 10
www.namc.danfoss.com
1.800.432.6367
IND.MC.12.15.01
Cooling
Danfoss VLT Series units are all designed for optimum thermal efficiency. On the high power units (>125 HP/460 VAC), the power component cooling air and internal electronics air are isolated, preventing the potential introduction of contaminants.
Solution The grinding mill (2) runs at variable speed and is controlled by a VLT Adjustable Frequency Drive. The max. torque is set to a value that causes the VLT to go into current limit when the grinding mill is blocked. A stall monitor automatically cuts off the line contactor if the grinding mill slows down to an adjustable preset low speed limit and the grinding mill can be manually cleared. If the grinding mill is partially blocked or overloaded by too much material in the tank (1), the VLT can remain in current limit and the grinding mill will continue to run at reduced speed. If the flow of material into the tank is temporarily stopped, the grinding mill can usually clear itself. The speed of the grinding mill is dependent upon the level in the silo (3). The level controller (4) sends a signal to the VLT to regulate the level by controlling the speed of the grinding mill motor. The setpoint of the level controller keeps the level in the silo constant, therefore the pressure at the silo discharge is kept constant, thus controlling the amount of material discharged onto the conveyor.
VLT 5000
Advantages
4
The adjustable current limit and the built-in trip function prevent mechanical overload. A starting torque up to 160% of nominal motor torque enables restart of the grinding mill. The electronic reversing feature incorporated in the VLT helps to eliminate blocking and jamming. Less material spills over the conveyor onto the floor. Greater control reduces maintenance costs and downtime. The unit can be rapidly reset for different types of materials. The slip compensation feature in the VLT gives near constant speed that varies less than 1% with changing load.
www.namc.danfoss.com
1.800.432.6367
D 11
Drives Solutions
IND.MC.12.15.01
91 (L1) 3-Phase Power Input 92 (L2) 93 (L3) 99 (PE) External DC Bus Connection 88 (-) 89 (+) External 24 V DC Supply +10 V DC 0 - 10 V DC Ref. Input* 0 - 10 V DC Ref. Input* 35 (-) 36 (+) 50 (+10 V OUT) 53 (A IN) 54 (A IN) 55 (COM A IN) 0/4 - 20 mA Ref. Input* 60 (A IN) 12 (+24 V OUT) 13 (+24 V OUT) Reset* Preset Speed Run/Stop* Reverse* 16 (D IN) 17 (D IN) 18 (D IN) 19 (D IN) 20 (COM D IN) Q Stop Jog Setup Select* Setup Select* 27 (D IN) 29 (D IN) 32 (D IN) 33 (D IN)
Brake Resistor
Motor (PE) 95
(AUX RELAY) 01 (AUX RELAY) 02 (AUX RELAY) 03 (RELAY) 04 (RELAY) 05 (COM A OUT) 39 (A OUT) 42 Output Speed Indication* 0/4 - 20 mA (A OUT) 45 (P RS-485) 68 (N RS-485) 69 (COM RS-485) 61 + RS-485 Output Current Indication* 0/4 - 20 mA Run Indication* 50 VAC, 1 A Max Fault Indication* 240 VAC, 2 A Max
MOTION CONTROLS
D 12
www.namc.danfoss.com
1.800.432.6367
IND.MC.12.15.01
Analog Inputs
Two analog inputs for voltage signals and one input for current signals are provided for reference and feedback signals. A thermistor can also be connected to either voltage input. The two analog voltage inputs can be scaled in the range of 0-10 VDC; the current input in the range of 0-20 mA.
Digital Inputs
The VLT 5000 System offers eight fully programmable digital inputs for over thirty functions.
Pulse/Encoder Inputs
Two inputs are available for pulse scaling or for feedback from up to two encoders. VLT 5000 D
Relay Outputs
Relay outputs may be selected to indicate thirty different functions such as ready, run, trip, current above a customer preset value, current above current limit, frequency within customer preset limits, frequency above a customer preset value, electronic motor overtemperature protection warning, or that remote operation mode has been selected.
www.namc.danfoss.com
1.800.432.6367
D 13