Sie sind auf Seite 1von 10

AccessNET Product Catalogue

At home everywhere in the world of communications

LSA Plus

The KRONE Contact Difference


KRONEs 3-point Insulation Displacement Connection (IDC) method of termination gives durable quality connections.

The KRONE-PLUS Quick Connection Technique is highly reliable and costeffective wire connection system for modern telecommunications and data networks. It is a comprehensive system built around the widely accepted KRONE 10 pair termination module with its range of built-in features. This is complemented by an extensive selection of accessories for protection, circuit identification and testing. The product range has been enhanced by the development of innovative products for the data market. The KRONE LSA-PLUS system uses a unique Insulation Displacement Contact (IDC) technique which eliminates the need to wire-strip, solder or make screw terminations, and dramatically increases productivity. This system is supplied for connections in various fields like telecom, structured cable and industrial wiring.
2

1. Insulation clamping ribs hold wire firmly in position and isolate the contact area from vibration and other forms of mechanical stress. 2. Flexible silver-plated contacts, positioned at 45 angle across the axis of the wire, make a solid, gas tight connection 3. Constant axial and torsional restoring forces, created by the unique contract and plastic housing, maintain a durable connector

Positioning contacts at a 45 angle leaves more wire between contact points and provides a more reliable, stress resistant connection

Positioning contacts at a 90 angle produces a point of weakness subject to possible breakage

LSA Plus

DISCONNECTION CONTACT
KRONE Disconnection Modules use a normally closed two piece contact, with a convenient disconnection feature. By inserting a Disconnect Plug into a wire pair, you can temporarily or permanently disconnect the circuit. A Test Cord can be inserted into a pair to test each side (look both ways) of the circuit independently. This greatly accelerates fault identification. The centre contact point can also be used for monitoring or overvoltage protection.

CONNECTION CONTACT
KRONE Connection Modules use a one piece contact, which provides a continuous link between feeder and jumper wiring. The centre contact point allows for easy parallel testing, monitoring, patching and over-voltage protection.

SWITCHING CONTACT
KRONE Switching Modules use a normally opened, two piece contact. Switching Modules offer high density termination and patching. This allows the user to double the number of terminations without loss in performance.

KRONE COMPONENTS MUST PASS THESE TESTS:


Contact resistance test The cornerstone of all KRONE reliability tests, it indicates the reaction of KRONE LSA-PLUS contacts to a variety of test loads. Insulation resistance test KRONE tests the resistance between the insulated contacts of KRONE connectors. Vibration resistance test KRONE determines whether building vibrations and other load causes contact disturbance in KRONE contacts. KRONE Quality The quality of KRONE LSA-PLUS contact is not reduced, even after the toughest continuous load. KRONE Quality High insulation resistance is maintained even under extremely humid conditions. KRONE Quality No contact disturbance; high contact and grip forces are sufficient to maintain both the connector and the connection in the defined position. KRONE Quality No changes to the KRONE LSA-PLUS contact or housing that could impede functional or operational reliability. . KRONE Quality Contact quality is not reduced, even under these extreme conditions.

Contact pressure relief test KRONE simulates artificial ageing by storing the contacts for longer periods at higher temperatures. The quality of the contact is subsequently tested. Temperature shock test KRONE uses this test to determine whether frictional corrosion occurs under extreme temperature changes and whether temperature reactions in theconnector housing have avoidable effects. Humidity resistance test KRONE tests the effects of high humidity on contacts and insulation material. Corrosive atmosphere test KRONE tests how the contacts react to the effect of harmful gases in an aggressive industrial atmosphere.

KRONE Quality Not even high humidity effects contacts or insulation resistance. KRONE Quality Most aggressive constituents in the atmosphere do not affect contact quality.

This is is a small selection from the extensive program of KRONE quality tests. The test describes here are representative of numerous scientific experiments, including joint international efforts with several universities and testing institutes. 3

LSA Plus

LSA-PLUS ELECTRICAL DATA


(after four days exposure to a climate of 40O C and 93% relative humidity.) Insulation Resistance................................................>5x104M Dielectric Strength................................................>2000Vrms Current Rating..............................>Current carrying capacity ..........................................................of terminated conductor LSA-PLUS Contact Contact Resistance.........................................................1m ..............................................................< 5m guaranteed Total Contact Resistance - Including Insulation Displacement Contact and Disconnecting Contacts........................< 10m Contact Spring Force for Disconnecting Contacts........................3N (approx. 300g) Number of Reterminations...........................................> 2 0 0 Coupling Capacitance Between Wires..........................<1pF Plastic Housing Material..................Thermoplastic Polyester ...................................................................Self Extinguishing Oxygen Index................................................................>28%

LSA-PLUS TECHNICAL DATA


Disconnection, Connection and Earth Modules for Plastic Insulated Copper Conductors Copper Conductor Diameter...........................0.40 - 0.80mm ........................................................................(AWG 26 - 20) Multistrand Conductor...................................7/0.2 - 7/.32mm Insulation Diameter.........................................0.70 - 1.50mm Number of Equal Diameter Solid Conductors Per Slot........2 max. (up to 0.65mm each) Number of Equal Diameter Multistrand Conductors Per Slot..................................1 max. Environmental Data Environment for use.................Indoors or enclosed cabinets ......................................outdoors with a minimum. degree of ...................................................protection to IP54 (IEC 529) Storage temperature.........................................-40O to +90OC Operating temperature......................................-40O to +70OC Max. operating humidity.......................93% relative humidity ......................................................................non-condensing

INSTALLATION INSTRUCTIONS FOR THE LSA-PLUS MODULES

1. Fix frame, make earth connection. 2. Introduce cable and strip the sheath (free cable length should equal distance of connection module placed furtherest away + 200mm). Then secure cable. 3. Form wires into 10-pair groups. 4. Termination of wires Take bottom most module and hold about 50 mm to 80 mm from allocated position. Push wire bundle at lease 150 mm through the module guide loop in the position (surplus wire in a loop). Pull wires between the guide notches and lay into contact slots. Terminate wires with the Connection Tool. Discard surplus wire.

5. Jumpering Discard surplus wire. Press jumper wires into the contact slot and connect with the Connection Tools pairs 1-10. Take all jumpers to the left side. Lead jumper wires through jumper guide on left hand side of the module as required. 6. Wire removal Wire should be removed using hook housed at the side of the tool. 7. Removal of modules from the distribution frame. To remove module from backmount frame use the swing-out module extractor on the insertion tool.

LSA Plus Series 2

Modules
LSA Plus Series 2 Disconnection Module
Description
Series 2 Disconnection Module 2/10 Series 2 Disconnection Module 2/8

LSA PLUS SERIES 2

Part No.
6089 2 011-02 6036 2 002-00

Pack Quantity
1 1

Disconnection Module for 8 or 10 pairs with disconnection contact for opening the circuit, testing possible in both the directions or insertion of over voltage protection magazine or Integrated Protection Module (IPM).

LSA Plus Disconnection Module 2/5


Description
Series 2 Disconnection Module 2/5

Part No.
6904 2 204- 00

Pack Quantity
1

Disconnection Module for 5 pairs with disconnection contact for opening the circuit, testing possible in both the directions.

LSA Plus Earth Module


Description
Earth Module 2/30 Earth Module 2/38

Part No.
6036 2 006-00 6089 2 017-07

Pack Quantity
1 1

Back Mount Frame


Black Mount Frame Series 2 (2/8 & 2/10)
Description
Backmount Frame, 2/10, 1 way Backmount Frame, 2/10, 2 way Backmount Frame, 2/10, 3 way Backmount Frame, 2/10, 5 way Backmount Frame, 2/10, 10 way Backmount Frame, 2/10, 11 way Backmount Frame, 2/10, 3 way Backmount Frame, 2/10, 5 way Backmount Frame, 2/10, 10 way Backmount Frame, 2/10, 11 way Backmount Frame, 2/8, 9 way Backmount Frame, 2/8, 17 way

Part No.
6442 3 230-01 6050 3 230-02 6050 3 230-03 6050 3 230-05 6050 3 230-10 6050 3 230-11 6442 3 230-03 6442 3 230-05 6442 3 230-10 6442 3 230-11 6441 3 230-09 6441 3 230-17

Pack Quantity
1 1 1 1 1 1 1 1 1 1 1 1

Back Mount Frame 2/10 or 2/8 to mount LSA PLUS modules 2/8 or 2/10. For indoor use directly on MDFs, Walls, Wall Mount Frames, boxes as well as weather proof out door distribution boxes.

Back Mount Frame CT Block


Description
Back Mount Frame 2/10 6 way Back Mount Frame 2/10 11 way

Part No.
6901 2 006-14 6901 2 006-13

Pack Quantity
1 1

Back Mount Frame 2/10 for cabinets and pillars. For mounting LSA PLUS modules 2/10.

LSA Plus Series 2

MDF Tag Blocks


MDF Tag Block 100 pair
Description
MDF Tag Block 22.5 mm. pitch MDF Tag Block 25 mm. pitch

Part No.
6901 1 001-01 6901 1 001-11

Pack Quantity
1 1

MDF Tag Blocks 2/10 for 100 pair with 10 LSA PLUS disconnection Modules for use on Line Side (subscriber) of MDFs.

MDF Tag Block 64 pair


Description
MDF Tag Block 64 pair

Part No.
6901 1 002-11

Pack Quantity
1

MDF Tag Blocks 2/ 8 for 64 pair with 8 LSA PLUS disconnection Modules for use on Exchange Side (Switch) of MDFs.

CT Block for cross connect cabinets


Description
CT CT CT CT

Part No.
1 1 1 1 006-00 006-02 007-01 007-02

Pack Quantity
1 1 1 1

Box,100 pair connection modules 6901 Box,100 pair disconnection modules 6901 Box,50 pair connection modules 6901 Box,50 pair disconnection modules 6901

CT Blocks for 100 and 50 pairs, for pillars and cross connect cabinets with LSA PLUS disconnection or Connection modules.

LSA Plus Series 2

Protection
Single Pair Protection Plug
Description
Single pair protection plug

Part No.
6905 2 330-00

Pack Quantity
1

This provides both voltage and current protection for single pair on line side. The primary protection is built in by 3 pole GD Tube. The secondary over current protection is provided by Positive Thermal Coefficient resistor (PTC).

Protection Magazine 10 pair


Description
Magazine 10 pair

Part No.
6089 2 023-01

Pack Quantity
1

This provides voltage protection for 10 pairs on line side. The magazine can house up to ten 3 pole GD Tubes.

Accessories
Test Cords
Description
Test Cord 2/2, 2 pole open ended with 1 plug 2/2 1.5 m 3.0 6.0 Test Cord 2/2, 2 pole with 2 banana Plugs 1.5 3.0 6.0 Connection Cord 2/2 2 pole with Plugs 1.5 3.0 6.0 Test Cord 2/4, 4 pole open ended with 1 plug 2/4 1.5 3.0 6.0 Test Cord 2/4, 4 pole with 4 banana Plugs 1.5 3.0 6.0 Connection Cord 2/4 4 pole with 2 plug 1.5 3.0 6.0

Part No.
6624 2 071-00 6624 2 071-03 6624 2 071-06 6624 2 061-00 6624 2 061-03 6624 2 061-06 6624 2 081-00 6624 2 081-03 6624 2 081-06 6907 2 001-00 6907 2 001-03 6907 2 001-06 6907 2 501-00 6907 2 501-03 6907 2 501-06 6907 2 301-00 6907 2 301-03 6907 2 301-06

Pack Quantity
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

m m m m m m m m m m m m m m m m m

Disconnection Plugs
Description
Disconnection Plug 1 pair Disconnection Plug 10 pair

Part No.
6089 3 055-00 6089 3 130-01

Pack Quantity
1 1

Used for disconnecting single subscriber line or for simultaneous disconnection of all subscriber lines in LSA PLUS disconnection module 2/10.

LSA Plus Series 2

Accessories
Marking Caps
Description
Marking Caps

Part No.
6089 3 006-00

Pack Quantity
1

Single Pair marking cap for marking important lines in LSA PLUS connection or disconnection modules 2/10.

Dust Cover
Description
Dust Cover 2/10 deep, for 100 pairs Dust Cover 2/10 flat, for CT Block

Part No.
6092 3 034-00 6092 3 016-00

Pack Quantity
1 1

Label Holder
Description
Label Holder 2/10 Label Holder 2/8

Part No.
6092 2 012-01 6901 2 010-02

Pack Quantity
1 1

Plug Numbers
Description
Printed 0...9 Printed 10...100

Part No.
6900 3 017-00 6900 3 018-00

Pack Quantity
1 1

KRONE Insertion Tool


Description
Insertion Tool

Part No.
6089 2 003-00

Pack Quantity
1

The Krone LSA PLUS Insertion Tool can be used for both connection and disconnection modules, on MDFs, Pillars and DP Boxes.

LSA Plus Series 2

Indoor D.P. Boxes


Kronnection Boxes
Description
Kronnection Box I, 30 pair Kronnection Box II, 50 pair Kronnection Box III, 100 pair

Part No.
6436 1 013-20 6406 1 015-20 6437 1 020-20

Pack Quantity
1 1 1

Kronection Boxes are available in three compact sizes suitable for surface installation. Boxes are made up of self extinguishing polystyrene material.

Metal Connection Boxes


Description
Metal connection box 30 pair Metal connection box 50 pair Metal connection box 100 pair

Part No.
6901 1 500-01 6901 1 500-02 6901 1 500-03

Pack Quantity
1 1 1

Metal Boxes are available in three compact sizes suitable for surface installation. Boxes are made of CRCA sheet and come with powder coating.

Cross connect cabinet


Description
Cross connect cabinet 2000 pair

Part No.
6901 1 500-27 A

Pack Quantity
1

Cross Connect Cabinets is available for 2000 pairs capacity. It is made of CRCA sheet and come with powder coating. * Other sizes available on request.

LSA Plus Series 2

Outdoor / Indoor Boxes


Kronnection Box A 30
Description
Box A 30

Part No.
6902 1 001-29

Pack Quantity
1

The Kronection Box A-30 is designed to accommodate up to 30 pairs both in indoor and outdoor installation. They are made of glass fiber reinforced polyester. It protects the installed devices against dust and rain water (protection according to IP 54). The box can be mounted directly on the wall or on a pole with a pole mounting bracket.

Kronnection Box DT Plus


Description
DT Plus Module

Part No.

Pack Quantity
1

The weather proof box of thermoplastic polymer which satisfies protection class IP 44.The box is used in housing 2 pairs of drop wire modules of series DT Plus for leading drop wires to the indoor telephone line in to the subscriber premises.

DP Box Sliding Cover


Description
DP Box with sliding cover, 5 pair DP Box with sliding cover, 10/20 pair

Part No.
6902 1 001-33 6902 1 001-34

Pack Quantity
1 1

The DP Box sliding cover is designed to accommodate 5,10/20 pairs both in indoor and outdoor installation. They are made of thermoplastic polymer meeting TEC specifications. The box can be mounted directly on the wall or on a pole with a pole mounting bracket.

10