Sie sind auf Seite 1von 38

GENERAL CATALOGUE

Openers & Closers was founded in Barcelona in 1989, with the aim of manufacturing quality door locks and ensuring an efficient customer service. After 20 years of experience, O&C is one of the leading European manufacturers of electric strikes and electromagnetic locks, exporting approximately 90% of production in over 40 different countries. Such achievement is probably the result of the companys policy of constantly improving product quality while maintaining an affordable price, in combination with the staff engagement to educate, update and advise clients on a regular basis. O&C currently owns over 30 patents for technical and production innovations, entirely designed and manufactured in Spain. All our products have been tested by APPLUS+ Norcontrol and LGAI Technological Center. Nevertheless, higher quality means lower energy consumption and less waste generation thanks to longer product life. As a matter of fact, our products are guaranteed from 3 to 5 years. Our commitment to the environment is also witnessed by our respect of the RoHS. OPENERS & CLOSERS: INNOVATION, QUALITY & SERVICE.

ELECTRIC STRIKES

BASIC for door entry systems SYMMETRICAL for door entry systems SECURITY for access control systems SECURITY with electronic coil EMERGENCY for push bar locks
new

MINI for aluminum, wood & PVC doors WATERPROOF for outdoor applications ARMOURED for multibolt locks FIRE for RF-120 doors HIGH-SECURITY for access control systems & heavy-duty doors

new

BASIC
Fail-secure
The electric strike is locked when unenergized.

FOR DOOR ENTRY SYSTEMS


Fixed latch Adjustable latch Preload Voltage
8-14 V ac/dc 5-12 V ac/dc 12 V dc 24 V dc 8-14 V ac/dc 5-12 V ac/dc 12 V dc 24 V dc 8-14 V ac/dc 5-12 V ac/dc 12 V dc 24 V dc 8-14 V ac/dc 5-12 V ac/dc 12 V dc 24 V dc

References and features

References
DIN right add faceplate

References
DIN left add faceplate

10.0.00.B 10.0.00.J 10.0.00.E 10.0.00.F 10.1.00.B 10.1.00.J 10.1.00.E 10.1.00.F 11.0.00.B 11.0.00.J 11.0.00.E 11.0.00.F 11.1.00.B 11.1.00.J 11.1.00.E 11.1.00.F 12.0.00.B 12.0.00.J 12.1.00.B 12.1.00.J 13.0.00.B 13.0.00.J 13.1.00.B 13.1.00.J 12A.0.00.B 12A.0.00.J 12A.1.00.B 12A.1.00.J 13A.0.00.B 13A.0.00.J 13A.1.00.B 13A.1.00.J

20.0.00.B 20.0.00.J 20.0.00.E 20.0.00.F 20.1.00.B 20.1.00.J 20.1.00.E 20.1.00.F 21.0.00.B 21.0.00.J 21.0.00.E 21.0.00.F 21.1.00.B 21.1.00.J 21.1.00.E 21.1.00.F 22.0.00.B 22.0.00.J 22.1.00.B 22.1.00.J 23.0.00.B 23.0.00.J 23.1.00.B 23.1.00.J 22A.0.00.B 22A.0.00.J 22A.1.00.B 22A.1.00.J 23A.0.00.B 23A.0.00.J 23A.1.00.B 23A.1.00.J

Fail-secure with mechanical unlatching


It works just like the Fail-secure model but with mechanical release function.

Hold-open
The electric strike has a device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

8-14 V ac/dc 5-12 V ac/dc 8-14 V ac/dc 5-12 V ac/dc 8-14 V ac/dc 5-12 V ac/dc 8-14 V ac/dc 5-12 V ac/dc 9-14 V ac/dc 6-12 V ac/dc 9-14 V ac/dc 6-12 V ac/dc 9-14 V ac/dc 6-12 V ac/dc 9-14 V ac/dc 6-12 V ac/dc

Hold-open with mechanical unlatching

It works just like the Hold-open model but with mechanical release function.

Internal Hold-open
The electric strike has an internal device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

Internal Hold-open with mechanical unlatching


It works just like the Internal Hold-open but with mechanical release function.

Fixed latch

Dimensions
28

46

,8

symmetrical reversibility with DIN Right and Left

asymmetrical reversibility with DIN Left

90 33 ,5

Adjustable latch

Operation
21

Hold-open

Internal Hold-open

52

,3

with mechanical unlatching

Fail-secure

with mechanical unlatching

Hold-open

with mechanical unlatching

Internal Hold-open
opened closed opened closed

Coil features
Warning: When installing door releases with DC con105 nections, the electric strike latch should not exert any pressure on the door-release latch. Incorrect installation could cause door-release failure. Temperature test: Measured on coil surface, tolerance 10% C
Minutes (a 12 Vac) 5

8/14 V ac/dc
(12 0,7 A a 12 Vac)

5/12 V ac/dc
(8 0,6 A a 9 Vac)

12 Vdc 100% (60 0,20 A)

24 Vdc 100% (220 0,12 A)

65

77 53

C
Minutes 5 (a 9 Vac)

C
Hours 5

C
Hours 5 Other coils and voltages on demand

Technical features
Electric strikes with ac coils work properly even with a pressure up to 16Kg 300.000 guaranteed openings Withstands impacts up to 300 Kg Steel screws Low power consumption Corrosion resistant according to UNI ISO 9227 Standards Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

11

9,7

FACEPLATES
3

25
36 3

47,25

48

,5

23

25

,5

44

159

52

22,75

44

52

104

104,5

48,5

48,5

47,5

63,25

Reversible

01 61
3

GREY INOX
3mm

Reversible

32,75

Reversible

80

GREY
3 25

81

GREY
3 25

25

61,75

44

61,75

44

12,5

61,75

250

250

12,5

44

48,5

48,5

52

250

52

48,5

35

102

79

139,75

139,75

12

12

Reversible

Reversible

03 63
34

D3
2

C3

GREY/BROWN INOX
3mm

05 65

D5

C5

139,75

17

04 64

102

52

D4

C4

D63 C63

D65 C65

D64 C64

Adjustable latch (3mm)


3,25

64

12

240

Fixed latch Ref. 0


46,5

44

48

52

16

90

43,6

8,25

14

128

Standard adjustable latch Ref. 1


46,2 16,5 12,7

Right

DIN

Left

73
25

INOX
2

3mm

74

43,2

7,75

Shallow adjustable latch Ref. 2


Supplied on demand
46,2 16,5

48

43,2

6,15

44

250

Deep adjustable latch Ref. 3


52

Supplied on demand

80

36

46,2

16,5

12,7

80

43,2

13,3

Deep latch installation example Ref. 3


122
14
21,3
90
7

,4

9,4

33

,4

ESP2

Right

DIN

Left

20

INOX

2mm

21

52

12,7

12,7

52

FACEPLATES
36 ,5

84
106,9

GREY CHROME BRASS

84
52
25

84

Reversible
25

145

48,5

44

172

16 BROWN
R 10

52

10

R 10

17 BROWN

R1 0

32

Reversible
2

Reversible
32

10

52

44

12

250

250

12

44

102

102

48,5

52

12

12

R
32

10

R1 0

10

R 10

Right

DIN

25

25

10

10

10

Left
2

08

BROWN
2

09

Right

DIN

Left
R 10

12

BROWN
R

13
R 10
10

10

44

250

250

44

52

250

35

79

35

79

12

12

52

32

Right

DIN

25

25

32

10

10

10

10

Left

10

BROWN

11

Right

DIN

Left

14

BROWN

15

Door Handedness
DIN definition: The door is viewed from the side on which the hinges are visible.

DIN Left

DIN Right

DIN Left

DIN Right

SYMMETRIC
References and features
Fail-secure
The electric strike is locked when unenergized.

FOR DOOR ENTRY SYSTEMS


Reversible Adjustable Preload latch Electronic protection Voltage
8-14 V ac/dc 5-12 V ac/dc 12 V dc 24 V dc
latch (1) add faceplate

References
30.1.00.B 30.1.00.J 30.1.00.E 30.1.00.F 31.1.00.B 31.1.00.J 31.1.00.E 31.1.00.F 34.1.00.E 34.1.00.F 32.1.00.B 32.1.00.J 33.1.00.B 33.1.00.J 32A.1.00.B 32A.1.00.J 33A.1.00.B 33A.1.00.J

Fail-Secure with mechanical unlatching


It works just like the Fail-secure model but with mechanical release function.

8-14 V ac/dc 5-12 V ac/dc 12 V dc 24 V dc

Fail-safe
The electric strike is locked when energized.

12 V dc 24 V dc 8-14 V ac/dc 5-12 V ac/dc 8-14 V ac/dc 5-12 V ac/dc 9-14 V ac/dc 6-12 V ac/dc 9-14 V ac/dc 6-12 V ac/dc

Hold-open
The electric strike has a device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

Hold-open with mechanical unlatching


It works just like the Hold-open model but with mechanical release function.

Internal Hold-open
The electric strike has an internal device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

Internal Hold-open with mechanical unlatching


It works just like the Internal Hold-open but with mechanical release function.

Fail-secure

with mechanical unlatching

Fail-secure

Hold-open

Hold-open

with mechanical unlatching

Internal Hold-open

with mechanical unlatching

Internal Hold-open

Fail-safe

Operation
Internal hold-open

Dimensions
29

10

21

12 52

11

Opened

Closed
12

69

Coil features
Warning: When installing door releases with DC connections, the electric strike latch should not 105 exert any pressure on the door-release latch. Incorrect installation could cause door-release failure. Temperature test: Measured on coil surface, tolerance 10% C
Minutes (a 12 Vac) 5

8/14 V ac/dc
(14 0,7 A a 12 Vac)

5/12 V ac/dc
(8 0,6 A a 9 Vac)

12 Vdc 100% (50 0,25 A)

24 Vdc 100% (185 0,12 A)

65

77 53

C
Minutes 5 (a 9 Vac)

C
Hours 5

C
Hours 5

Other coils and voltages on demand

Technical features
Electric strikes with ac coils work properly even with a pressure up to 16Kg. 300.000 guaranteed openings Withstands impacts up to 280 Kg. Steel screws Low power consumption Corrosion resistant according to UNI ISO 9227 Standards Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

FACEPLATES
3

25

3 25

47,25

159

52

63,25

Reversible
3

Reversible
3 25
25 3
25

30,75

48,5

61

INOX

48,5

3mm

44

01

GREY

30,75

52

110

02 62

GREY INOX
3mm

44

61,75

44

61,75

44

12,5

61,75

250

250

12,5 250

48,5

48,5

52

44

52

48,5

35

102

79

139,75

139,75

12

12

Reversible

Reversible

03 63

D3

C3
2

GREY/BROWN INOX
3mm

05 65

D5

C5

139,75

17

04 64

102

52

D4

C4

D63 C63
34

D65 C65

D64 C64

Adjustable latch (3mm)


44 12 240

64

48

14

90

52

128

Standard adjustable latch Ref. 1


47,1

14,7

Right

DIN

11,6

Left

73
25

INOX
2

3mm

74
Supplied on demand

5,4 44,7

Deep adjustable latch Ref. 3


47,1

14,7

48

11,6

13,5

44

44,7

250

Deep latch installation example Ref. 3


52

80

36

5, 5

80

12

122

52

14

ESP3
Right DIN Left

20

INOX

2mm

21

21,3

,3 69

12

FACEPLATES
36 ,5

84
106,9

GREY CHROME BRASS

84
52
25

84

Reversible

25

145

48,5

44

172

R
R
32

10

R1 0

Reversible

16

BROWN

Reversible

17

32

10

52

44

12

250

250

12

44

102

102

48,5

52

12

12

32

25

25

10

R1 0

10

52

10

R 10

BROWN

R 10

10

10

10

Right

DIN

Left

08

BROWN

09

Right

DIN

Left

12

BROWN

13

Door Handedness
DIN definition: The door is viewed from the side on which the hinges are visible.

DIN Left

DIN Right

DIN Left

DIN Right

References and features


Fail-secure

SECURITY
The electric strike is locked when unenergized.

FOR ACCESS CONTROL SYSTEMS


Fixed latch Preload Electronic protection Voltage
8-14 V ac/dc 12 V dc 24 V dc 8-14 V ac/dc 12 V dc 24 V dc 12 V dc 24 V dc 12 V dc 24 V dc 12 V dc 24 V dc 12 V dc 24 V dc 9-14 V ac/dc 4R2A.4.00.L 4R4.4.00.M 4R4.4.00.N 4R8.4.00.M 4R8.4.00.N

References
DIN right add faceplate

DIN left add faceplate

References
4L0.4.00.L 4L0.4.00.M 4L0.4.00.N 4L6.4.00.L 4L6.4.00.M 4L6.4.00.N 47.4.00.P 47.4.00.N 4L4.4.00.M 4L4.4.00.N 4L8.4.00.M 4L8.4.00.N 49.4.00.P 49.4.00.N 4L2A.4.00.L

4R0.4.00.L 4R0.4.00.M 4R0.4.00.N 4R6.4.00.L 4R6.4.00.M 4R6.4.00.N

Fail-secure with 1 microswitch

It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

Fail-secure with 2 microswitch Fail-safe

It works just like the Fail-secure model plus 2 electrical switching device that detects the status of the electric strike and the door. The electric strike is locked when energized.

Fail-safe with 1 microswitch Fail-safe with 2 microswitch Internal Hold-open

It works just like the Fail-safe model plus an electrical switching device that detects the status of the door. It works just like the Fail-safe model plus 2 electrical switching device that detects the status of the electric strike and the door. The electric strike has an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.

Fail-secure

Internal Hold-open

Fail-safe

Fail-secure

1 microswitch

Fail-safe

Fail-secure

2 microswitch

Fail-safe

Operation
Fail-secure Fail-safe

asymmetrical reversibility

opened

closed

closed

opened

Interconnection between principal and secondary microswitch


Connection Door closed and lever locked Door released Door released and lever unlocked Common Electric connection Principal microswitch S1 Door released connection Common Door closed connection Electric connection Secondary microswitch S2 Locked lever connection Common Unlocked lever connection

Schematic electric diagram


Light

Light

Principal microswitch S1 Intensity Operating speed Operating frecuency Contact resistance Ambient temperature Humidity Life expectancy 1A/125 Vac 0,5A/30 Vdc 1 at 500 mm/second (at pin plunger) Mechanical: 200 operations per minute Electrical: 30 operations per minute Standard type: 30 m max. From -25C a 65C (without ice) 85% RH max. (5 a 35C) Mechanical: 300.000 operations min. Electrical: 30.000 operations min.

Secondary microswitch S2 0,5A/30 Vdc 1 at 500 mm/second (at pin plunger) Mecnica: 200 operations per minute Elctrica: 30 operations per minute Standard type: 30 m max. From -25C a 70C (without ice) 85% RH max. (5 a 35C) Mechanical: 30.000 operations min. Electrical: 30.000 operations min.
Power supply Push button Secondary microswitch S2

Principal microswitch S1

Principal microswitch S1

Push button

Unlocked lever (electric strike open) Door opened Door closed Door opened Door closed

Power supply

Coil features
L
Warning: When installing door releases with DC connections, the electric strike latch should not exert any pressure on the door-release latch. Incorrect installation could cause door-release failure. Temperature test: Measured on coil surface, tolerance 10%

8/14 V ac/dc
(20 0,5 A a 12 Vac)

M 12 Vdc 100%
(70 0,17A)

N 24 Vdc 100%
(240 0,10A) FAIL-SAFE FAIL-SECURE 57

12 Vdc 100% (54 0,22 A) 2 microswitch

62

62 51

FAIL-SAFE FAIL-SECURE

66 56

C
Minutes (a 12 Vac) 5

C
Hours 5

C
Hours 5

C
Hours 5

Technical features
Reinforced mechanism box Stainless steel lock cover Steel latch and screws Electric strikes with 12V ac coils are released by applying a pressure up to 16 kg Withstands impacts and pressures up to 500 Kg, getting destroyed at 700kg. 300.000 guaranteed openings Low power consumption

Other coils and voltages on demand

Corrosion resistant according to UNI ISO 9227 Standards Complies with electromagnetic compatibility standard 2004/108/CE (EN55014). Latch adjustment regulator (is supplied on demand)

SECURITY
References and features
Fail-secure
The electric strike is locked when unenergized.

WITH ELECTRONIC COIL


Fixed latch Preload Voltage References
DIN right add faceplate

References
DIN left add faceplate

ac/dc intermittent

12 V ac/dc 24 V ac/dc 12 V ac/dc 24 V ac/dc

4R0.4.00.X 4R0.4.00.Z 4R2A.4.00.X 4R2A.4.00.Z

4L0.4.00.X 4L0.4.00.Z 4L2A.4.00.X 4L2A.4.00.Z

Internal Hold-open

The electric strike has an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.

Door access control with two ac/dc power supplies


Digital installations of telephone and video intercoms are generally equipped with batteries to supply the system in cases of power cuts. When an access control system is working on: ac current: the electric strike opens with a pressure of up to 16 kg on the latch and the coil emits the standard ac buzzing sound. dc current (from the batteries): the electric strike does not open under pressure and emits no sound. important notice: dc current does not admit pressure during electromagnetic release.

Applications
Security electric strikes with vibrating ac/dc electronic coil are suitable for all digital telephone and video intercom installations. The electronic coil is activated whether it is working in ac/dc current, the standard buzzing signal is always emitted and the door release will open at any time under a pressure up to 14 kg. Important notice: It should be noted that the electrical connections of the electronic coil are not polarized, so it should be connected in the same way as a fail secure electric strike. It is recommended to install this kind of electric strike for all digital access control installations. These top quality electric strikes, specially designed for security professionals, withstand pressures of up to 700 kg.

Dimensions
29 ,5

20,5

3,5 45 10 6,4

52

11

9,2

10

Technical features
Reinforced mechanism box Stainless steel lock cover Steel latch and screws Electric strikes with electronic coils are released by applying a pressure up to 14kg Withstands impacts and pressures up to 500 Kg, getting destroyed at 700 Kg 300.000 guaranteed openings. Low power consumption Corrosion resistant according to UNI ISO 9227 Standards Complies with electromagnetic compatibility standard 2004/108/CE (EN55014)

Door Handedness
DIN definition: The door is viewed from the side on which the hinges are visible.

DIN Left

DIN Right

DIN Left

DIN Right

FACEPLATES
3 25

25

65,5

159

64

52

52

61
44

250

12

43 INOX
3mm

INOX

3mm

44 142

49,5

Reversible
3 25

Reversible
3

70

44

25

65,5

200

52

INOX

280

66
3mm
44

96

67 INOX
3mm

44

13

90,5

140

Reversible
2

Reversible
R
172 48,5

70

42

52

10

16 BROWN
10

44

R 10

17 BROWN

52

32

25

R1 0

Reversible
25 2
32

Reversible
25

10

10

61,75

48,5

48,5

61,75

250

250

44

44

139,75

12

12

70

70

139,75

52

52

0 R1

10

10

Right

DIN

Left

44

BROWN

47

Right

DIN

Left

45

BROWN

48

10

10

32

R 10

10

EMERGENCY
References and features
Fail-secure
The electric strike is locked when unenergized.

FOR PUSH BAR LOCKS


Symmetrical reversibility Fixed latch Preload Electronic protection Voltage
8-14 V ac/dc 12 V dc 24 V dc
add box

References
40.6.00.L 40.6.00.M 40.6.00.N 46.6.00.L 46.6.00.M 46.6.00.N 47.6.00.P 47.6.00.N 44.6.00.M 44.6.00.N 48.6.00.M 48.6.00.N 49.6.00.P 49.6.00.N 42A.6.00.L

Fail-secure with 1 microswitch


It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

8-14 V ac/dc 12 V dc 24 V dc

Fail-secure with 2 microswitch Fail-safe

It works just like the Fail-secure model plus 2 electrical switching device that detects the status of the electric strike and the door. The electric strike is locked when energized.

12 V dc 24 V dc 12 V dc 24 V dc 12 V dc 24 V dc 12 V dc 24 V dc 9-14 V ac/dc

Fail-safe with 1 microswitch Fail-safe with 2 microswitch Internal Hold-open

It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.

It works just like the Fail-safe model plus 2 electrical switching device that detects the status of the electric strike and the door. The electric strike has an internal device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

Internal Fail-secure Hold-open

Fail-safe

Fail-secure

1 microswitch

Fail-safe

Fail-secure

2 microswitch

Fail-safe

Operation
Fail-secure Fail-safe

Schematic electric diagram


Light Light

Principal microswitch

S1

S1

Principal microswitch

82 82

BLACK RED

83 83

BLACK RED

85 85

BLACK RED
opened closed closed opened

Secondary microswitch

S2

Push button Unlocked lever (electric strike open)

Push button

Interconnection between principal and secondary microswitch


Principal microswitch S1 Intensity Operating speed Operating frecuency Contact resistance Ambient temperature Humidity Life expectancy 1A/125 Vac 0,5A/30 Vdc 1 at 500 mm/second (at pin plunger) Mechanical: 200 operations per minute Electrical: 30 operations per minute Standard type: 30 m max. From -25C a 65C (without ice) 85% RH max. (5 a 35C) Mechanical: 300.000 operations min. Electrical: 30.000 operations min. Secondary microswitch S2 0,5A/30 Vdc 1 at 500 mm/second (at pin plunger) Mechanical: 200 operations per minute Electrical: 30 operations per minute Standard type: 30 m max. From -25C a 70C (without ice) 85% RH max. (5 a 35C) Mechanical: 30.000 operations min. Electrical: 30.000 operations min.
Electric connection

Power supply

Door opened Door closed

Power supply

Door opened Door closed

Connection

Door closed and lever locked Door released Door released and lever unlocked Common

Electric connection

Principal microswitch S1 Door released connection Common Door closed connection Secondary microswitch S2 Locked lever connection Common Unlocked lever connection

Coil features
L
Warning: When installing door releases with DC connections, the electric strike latch should not exert any pressure on the door-release latch. Incorrect installation could cause door-release failure. Temperature test: Measured on coil surface, tolerance 10%

8/14 V ac/dc
(20 0,5 A a 12 Vac)

M 12 Vdc 100%
(70 0,17A)

N 24 Vdc 100%
(240 0,10A) FAIL-SAFE FAIL-SECURE 57

12 Vdc 100% (54 0,22 A) 2 microswitch

62

62 51

FAIL-SAFE FAIL-SECURE

66 56

C
Minutes (a 12 Vac) 5

C
Hours 5

C
Hours 5

C
Hours 5 Other coils and voltages on demand

Technical features
Reinforced mechanism box Stainless steel lock cover Steel latch and screws Electric strikes with 12V ac coils are released by applying a pressure up to 16 kg Withstands impacts and pressures up to 500 Kg, getting destroyed at 700kg. 300.000 guaranteed openings. Low power consumption

Corrosion resistant according to UNI ISO 9227 Standards Complies with electromagnetic compatibility standard 2004/108/CE (EN55014). Latch adjustment regulator (is supplied on demand)

11

SURFACE BOXES
82 82 BLACK RED
44,65

Deep surface box


Installation instructions: 1- Unscrew the 2 screws that attach the electric strike mechanism to the box 82 and remove the electric strike. 2- Make the electrical connection of the electric strike. 3- Place the electric strike back in the box 82 with the 2 screws holding it. 4- Place the electric strike between 12-14 mm. from the panic device, the latch must be aligned. Set the box 82 on the frame with 4 screws. 5- Press the black nylon trim on top of the box 82 in order to hide the 4 holding points.

160

83 83

BLACK RED
27,35

Standard surface box


Installation instructions: 1- Unscrew the 2 screws that attach the electric strike mechanism to the box 83 and remove the electric strike. 2- Locate the C-83 accessories under the box 83 until the lach gets aligned. 3- Pass the electric cable through the holes of the C-83 accessories 4- Place the C-83 accessories on the door at 12-14 mm. from the panic device.Hold them with the screws. 5- Make the electrical connection of the electric strike. 6- Place the electric strike back in the box 83 with the 2 screws holding it. 7- Set the box 83 on the C-83 accessories with 4 screws. 8- Press the black nylon trim on top of the box 83 in order to hide the 4 holding points.

160

85 85

BLACK RED
27,35

Shielded surface box


Set made up of one metalic base on which to install the electric strike and a sturdy protective box. This protective box is designed so that the points of union of the electric strike and the door frame are not visible, ensuring the shield of the electric strike. Installation instructions: 1- Place the electric strike on the metalic base. 2- Place the C-83 accessories under the metalic base until the latch gets aligned. 3- Pass the electric cable through the holes of the C-83 accessories and the metalic base. 4- Place the set on the door frame at 12-14 mm. from the panic device.Hold them with 2 screws. 5- Make the electrical connection of the electric strike. 6- Protect the set with the shielded box 85. Hold the box on the door frame with 4 screws. 7- Press the black nylon trim on top of the shielded box 85 in order to hide the 4 holding points. 7 6

160

43

C83

160 48

1 2

Latch and electric strike aligment 4

Part of the door frame will be cut to facilitate the turning of the electric strike latch.

installation example

12

MINI
Fail-secure

References and features

FOR ALUMINUM, WOOD & PVC DOORS


Radial Adjustable turning Reversible Preload latch latch Electronic protection Voltage
9-16 V ac/dc 6-12 V ac/dc 12 V dc 24 V dc 50.1.00.B 50.1.00.J 50.1.00.E 50.1.00.F 51.1.00.B 51.1.00.J 51.1.00.E 51.1.00.F 56.1.00.B 56.1.00.E 56.1.00.F 54.1.00.E 54.1.00.F 58.1.00.E 58.1.00.F 52.1.00.B 52.1.00.J 53.1.00.B 53.1.00.J

new
References

latch (1) add faceplate

The electric strike is locked when unenergized.

Fail-secure with mechanical unlatching


It works just like the Fail-secure model but with mechanical release function.

9-16 V ac/dc 6-12 V ac/dc 12 V dc 24 V dc

Fail-secure with microswitch


It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

9-16 V ac/dc 12 V dc 24 V dc 12 V dc 24 V dc 12 V dc 24 V dc

Fail-safe
The electric strike remains in closed position, while the coil is selected. When the electric current is stopped, the electric strike stays in open position. Like the Fail-safe model plus an electrical switching device that detects the status of the door.

Fail-safe with microswitch

Hold-open
The electric strike has a device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.

9-16 V ac/dc 6-12 V ac/dc 9-16 V ac/dc 6-12 V ac/dc

Hold-open with mechanical unlatching


It works just like the Hold-open model but with mechanical release function.

Fail-secure

with mechanical unlatching

Fail-secure

Fail-secure

with microswitch

Hold-open

Dimensions
65
9,8 13 9,8

with mechanical unlatching

Hold-open

Fail-safe

Fail-safe

with microswitch

46,6

,5

72

5 ,5

5,9

46,6

13

9,8

5,9 16

9,8

16,5

28

,1

Coil features
Warning: When installing door releases with DC connections, the electric strike latch should not exert any pressure on the door-release latch. 77 Incorrect installation could cause door-release failure. Temperature test: Measured on coil surface, tolerance 10%
60 9 Vac 46 39 6 Vac

9/16 V ac/dc
(20 0,480 A a 12V ac) 16 Vac 12 Vac 58 85

6/12 V ac/dc
(8,5 0,820 A a 9V ac) 12 Vac 68

12 Vdc 100%
(42 0,275 A)

24 Vdc 100%
(192 0,120 A)

9 Vac

62

C
Minutes 5

C
Minutes 5

C
Hours 5

C
Hours 5

Other coils and voltages on demand

Technical features
Electric strikes with ac coils work properly even with a pressure up to 16Kg. 300.000 guaranteed openings Reinforced anchor levers Withstands impacts up to 400 Kg. Steel screws Low power consumption Corrosion resistant according to UNI ISO 9227 Standards Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

13

FACEPLATES
6

44,5

243,9

66,5

2,1

24

Right

DIN

Left

33,2

,1 12

66,5

24

227,5

44,5

48,3

130,2

22

33,2

48,3

65,3

INOX

3mm

23

INOX

3mm

24,3

R 10

INOX

3mm

25
,5 32 18 ,8

INOX

3mm

Right

DIN

Left

24

227,5

12

,1

26

INOX

66,5

3mm

Reversible

14

24,3

WATERPROOF
References and features
Fail-secure
The electric strike is locked when unenergized.

FOR OUTDOOR APPLICATIONS


Preload Electronic protection Voltage
8-14 V ac/dc 12 V dc 24 V dc

Fixed latch

References
DIN right add faceplate

References
DIN left add faceplate

7R0.4.00.L 7R0.4.00.M 7R0.4.00.N 7R6.4.00.L 7R6.4.00.M 7R6.4.00.N 7R4.4.00.M 7R4.4.00.N 7R8.4.00.M 7R8.4.00.N 7R2A.4.00.L

7L0.4.00.L 7L0.4.00.M 7L0.4.00.N 7L6.4.00.L 7L6.4.00.M 7L6.4.00.N 7L4.4.00.M 7L4.4.00.N 7L8.4.00.M 7L8.4.00.N 7L2A.4.00.L

Fail-secure with 1 microswitch


It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

8-14 V ac/dc 12 V dc 24 V dc

Fail-safe

The electric strike remains in closed position, while the coil is selected. When the electrical current is stopped, the strike stays in open position.

12 V dc 24 V dc 12 V dc 24 V dc 9-14 V ac/dc

Fail-safe with 1 microswitch Internal Hold-open

It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.

The electric strike has an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.

Fail-secure

Fail-safe

Internal Hold-open

Fail-secure

1 microswitch

Fail-safe

Schematic electric diagram with microswitch


Power supply

Dimensions
36

light COM NC COIL COIL Push button NO Push button

light COM NO NC
4,3

,2 93 ,9 98

Security coil support

100% waterproof box

Magnet + 100% waterproof REED

Coil features
Warning: When installing door releases with DC connections, the electric strike latch should not exert any pressure on the door-release latch. Incorrect installation could cause door-release failure. Temperature test: Measured on coil surface, tolerance 10% C
Minutes (a 12 Vac) 5 62

8/14 V ac/dc
(20 0,5 A a 12 Vac)

M 12 Vdc 100%
(70 0,17A)

N 24 Vdc 100%
(240 0,10A) FAIL-SAFE FAIL-SECURE

62 51

FAIL-SAFE FAIL-SECURE

66 56

C
Hours 5

C
Hours 5

Technical features
Electric strikes with ac coils work properly even with a pressure up to 15Kg. Waterproof mechanism box Withstands impacts and pressures up to 300 Kg, getting destroyed at 500kg.
25 3

Other coils and voltages on demand 300.000 guaranteed openings. Reinforced mechanism box Low power consumption. Stainless steel screws.
31 3

Protected against water projected in all directions (IP54). Corrosion resistant according to UNI ISO 9227 Standards Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

25

73,5

73,5

40,5

40,5

73,5

250

40,5

13

250

45,5

85

45,5

45,5

13

27

15

27

20

15
131

Reversible

12

Reversible

131

27

Reversible

INOX

3mm

68

INOX
DIN definition: The door is viewed from the side on which the hinges are visible.

3mm

69

INOX

3mm

75

Door Handedness

131

85

250

21,2

15

ARMOURED
References and features
Fail-secure
The electric strike is locked when unenergized.

FOR MULTIBOLT LOCKS


Adjustable Preload latch Electronic protection Voltage
8-14 V ac/dc 12 V dc 24 V dc

References
DIN right add faceplate

References
DIN left add faceplate

9R0.1.00.L 9R0.1.00.M 9R0.1.00.N 9R4.1.00.M 9R4.1.00.N 9R2A.1.00.L 9R3A.1.00.L

9L0.1.00.L 9L0.1.00.M 9L0.1.00.N 9L4.1.00.M 9L4.1.00.N 9L2A.1.00.L 9L3A.1.00.L

Fail-safe

12 V dc 24 V dc 9-14 V ac/dc 9-14 V ac/dc

The electric strike is locked when energized.

Internal Hold-open with mechanical unlatching


The electric strike has a an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door and has mechanical unlatching.

Fail-secure

Fail-safe

Internal Hold-open

Operation

internal hold-open

Dimensions

,5 88 83 ,3 36

32

77

opened

closed

Coil features
Warning: When installing door releases with DC connections, the electric strike latch should not exert any pressure on the door-release latch. Incorrect installation could cause door-release failure. Temperature test: Measured on coil surface, tolerance 10% C
Minutes (a 12 Vac) 5 62

8/14 V ac/dc
(20 0,5 A a 12 Vac)

M 12 Vdc 100%
(70 0,17A)

N 24 Vdc 100%
(240 0,10A) FAIL-SAFE FAIL-SECURE

62 51

FAIL-SAFE FAIL-SECURE

66 56

C
Hours 5

C
Hours 5 Other coils and voltages on demand

Technical features
Designed for bolts-locked armoured doors. 4mm. distance between the latch and the first bolt of the electric strike. Withstands impacts and pressures up to 400 Kg, getting destroyed at 700kg. 300.000 guaranteed openings. Low power consumption. Reinforced mechanism box Steel screws.

Electric strikes with 12V ac coils are released by applying a pressure up to 16 kg Corrosion resistant according to UNI ISO 9227 Standards Complies with electromagnetic compatibility standard 2004/108/ CE (EN55014). Latch adjustment regulator (is supplied on demand) Stainless steel lock cover

Adjustable latch (3mm)


35 3

Faceplates

35

Standard adjustable latch Ref. 1

68,5

68,5

14,2

37

247

37

247

O 20
O 20

34,8

141,5

Reversible

Reversible

INOX

3mm

60
DIN definition: The door is viewed from the side on which the hinges are visible.

INOX

3mm

70
14,2 34,8 9,3 10,8

Door Handedness
16

141,5

Deep adjustable latch Ref. 3

10,8

23

FIRE
Fail-secure

FOR RF-120 DOORS


Fixed latch Preload Electronic protection Voltage
8-14 V ac/dc 12 V dc 24 V dc

References and features

References
DIN right add faceplate

References
DIN left add faceplate

24R0.4.00.L 24R0.4.00.M 24R0.4.00.N 24R6.4.00.L 24R6.4.00.M 24R6.4.00.N 24R4.4.00.P 24R4.4.00.N 24R8.4.00.P 24R8.4.00.N

24L0.4.00.L 24L0.4.00.M 24L0.4.00.N 24L6.4.00.L 24L6.4.00.M 24L6.4.00.N 24L4.4.00.M 24L4.4.00.N 24L8.4.00.M 24L8.4.00.N

The electric strike is locked when unenergized.

Fail-secure with 1 microswitch


It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

8-14 V ac/dc 12 V dc 24 V dc

Fail-safe

The electric strike is locked when energized.

12 V dc 24 V dc 12 V dc 24 V dc

Fail-safe with 1 microswitch

It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.

Fail-secure

Fail-safe

Fail-secure

1 microswitch

Fail-safe

Operation
Fail-secure Fail-safe

Schematic electric diagram with microswitch


NO NC COM light

opened

closed

closed

opened

Principal microswitch S1

Dimensions

29 ,5

9,2

20,5

3,5 45 10 6,4

52

11

Push button
10 7

Door opened Door closed

Coil features
Warning: When installing door releases with DC connections, the electric strike latch should not exert any pressure on the door-release latch. Incorrect installation could cause door-release failure. Temperature test: Measured on coil surface, tolerance 10% C
Minutes (a 12 Vac) 5 62

Power supply

8/14 V ac/dc
(20 0,5 A a 12 Vac)

M 12 Vdc 100%
(70 0,17A)

N 24 Vdc 100%
(240 0,10A) FAIL-SAFE FAIL-SECURE

62 51

FAIL-SAFE FAIL-SECURE

66 56

C
Hours 5

C
Hours 5 Other coils and voltages on demand

Technical features
Heat resistance: 1150 C for 2 Hours Approval standard UNE EN 1634 - 1, RF 120 Stainless steel lock cover Withstands impacts and pressures up to 1000 Kg 300.000 guaranteed openings Reinforced mechanism box Stainless steel screws Low power consumption
3

Electric strikes with 12V ac coils are released by applying a pressure up to 16 kg Corrosion resistant according to UNI ISO 9227 Standards Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).
3 25
3 25

Faceplates

25

52

65,5

65,5

64

250

44

52

159

12

44

44

49,5

142

70

90,5

44

43
Reversible

Reversible 3mm

Door Handedness

INOX

61 INOX 3mm

66 INOX 3mm

DIN definition: The door is viewed from the side on which the hinges are visible.

200

52

17

HIGH-SECURITY
References and features
Fail-secure
The electric strike is locked when unenergized.

FOR ACCESS CONTROL SYSTEMS & HEAVY DUTY DOORS


Electronic protection Voltage
8-14 V ac/dc 5-12 V ac/dc 12 V dc 24 V dc

new

Radial Adjustable turning Reversible Preload latch latch

References
latch (1) add faceplate

250.1.00.B 250.1.00.J 250.1.00.E 250.1.00.F 256.1.00.B 256.1.00.J 256.1.00.E 256.1.00.F 254.1.00.E 254.1.00.F 258.1.00.E 258.1.00.F 252.1.00.B 252.1.00.J

Fail-secure with 1 microswitch


It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

8-14 V ac/dc 5-12 V ac/dc 12 V dc 24 V dc

Fail-safe
The electric strike is locked when energized.

12 V dc 24 V dc 12 V dc 24 V dc 8-14 V ac/dc 5-12 V ac/dc

It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.

Fail-safe with 1 microswitch

Hold-open
The electric strike has a device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

Fail-secure

Fail-secure

with microswith

Fail-safe

Fail-safe

with microswith

Hold-open

Dimensions
43,8 15,3 11,65 11,65
28 70 0 ,5 ,5 78 28 ,5

6
20,5

43,8

2 15,3

11,65

Coil features
Warning: When installing door releases with DC connections, the electric strike latch should not 105 exert any pressure on the door-release latch. Incorrect installation could cause door-release failure. Temperature test: Measured on coil surface, tolerance 10% C
Minutes (a 12 Vac) 5

11,65

8/14 V ac/dc
(14 0,7 A a 12 Vac)

5/12 V ac/dc
(8 0,6 A a 9 Vac)

12 Vdc 100% (50 0,25 A)

24 Vdc 100% (185 0,12 A)

77 65 53

C
Minutes 5 (a 9 Vac)

C
Hours 5

C
Hours 5

Other coils and voltages on demand

Technical features
Electric strikes with ac coils work properly even with a pressure up to 16Kg. 300.000 guaranteed openings Steel levers Withstands impacts and pressures up to 1000 Kg Steel screws Low power consumption Corrosion resistant according to UNI ISO 9227 Standards Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

18

20,5

FACEPLATES
3 25
3 25

new
3 25

65,5

65,5

159

30,75

52

44

52

110

44

30,75

48,5

49,5

Reversible

90,5

44

200

52

Reversible
3

61
25

INOX

3mm

62

INOX
25

3mm
3

Reversible
3 25

66

INOX

3mm

61,75

44

61,75

44

12,5

61,75

250

12,5 250

250

48,5

48,5

52

44

52

48,5

35

102

79

139,75

139,75

12

12

Reversible

Reversible

63
34

D63 C63
2

INOX

3mm

65

D65 C65

139,75

17

102

52

64

D64 C64

25

64

44

12

240

48

52

48,5

44

172

14

90

128

R
32

10

R1 0

Reversible DIN

Reversible

Right

Left

73

INOX

3mm
2

74
32 2

16

BROWN
10

17
R 10

BROWN
10
R 10

52

44

12

250

250

12

44

102

102

48,5

52

12

12

R
32

10

R1 0

Right

DIN

25

25

10

10

Left

08

BROWN

09

Right

DIN

Left

12

BROWN

13 19

52

10

R 10

MAGLOCKS

new new

MICRO for cabins, lockers & drawers DOOR HOLDERS for fire doors MINI for access control & emergency exits UNIVERSAL for access control & emergency exits WATERPROOF for outdoor applications SHEARLOCKS for swing and sliding doors

20

MICRO

FOR CABINS, LOCKERS & DRAWERS

new

Dimensions

32 ,5

90

MEX70

39 ,5

24

7 ,2 69

For doors that open inwards

4 ,5

75

38

38

Electrical connection

32,9

Bracket

38

Power supply 12Vdc - 340mA

MBAX70

Power supply 24Vdc - 165mA

Bracket

U
For glass doors
16 28

Holding force: 700 N


41
70

MHAX70
21

DOOR HOLDERS
References DHI
Industrial door holder

FOR FIRE DOORS


Technical features
7

new

Dimensions
24 ,7

O
55

50

60

DHS

60

Basic door holder

28

15

50

Diameter: 50mm. Holding force: 600 N Power supply: 24 Vdc Electric connexion: 2 wires side or rear exit 24Vdc consumption: 0,085 A Power: 2W
60

O
55

DHB

Dual tension door holder

60

83 46 ,2 65

51

50

Diameter: 50mm. Holding force: 600 N Power supply: 12/24 Vdc 12Vdc consumption: 0,170 A 24Vdc consumption: 0,085 A Voltage change: with jumper Power: 2W Push button to unlock the door

55

90

42

,5

DHT

Timed door holder

83 65 46 ,2

51

65

50

Diameter: 50mm. Holding force: 600 N Power supply: 24 Vdc Timer: 3 seg. 24Vdc consumption: 0,085 A Power: 2W Push button to unlock the door

55

90

42

,5

DHD

Door holder with power-regulation

83 65 46 ,2

51

65

50

Diameter: 50mm. Max. Holding force: 600 N Min. Holding force: 300 N Power supply: 24 Vdc 600N consumption: 0,085 A Power: 2W Push button to unlock the door

55

90

42

,5

DFS

Door holder support

39 83

90

65

83

All models are equipped with ejector pins to overcome residual magnetism

80

80

22

192

39

MINI
Installation Mortise Rim

FOR ACCESS CONTROL & EMERGENCY EXITS


Fitting system round squared Led Reed Electronic protection Holding force
2800 N 2800 N 2800 N 2800 N 2800 N 2800 N 2800 N 2800 N x 2 2800 N x 2 2800 N x 2

References and features


Voltage 12/24 Vdc References
ME-200 ME-201 ME-210 ME-211 ME-400 ME-410 ME-420 ME-600 ME-610 ME-620

References

Packaging dimensions

Total weight

Electric consumption 12 Vdc 24 Vdc

Power

ME-200/210
249 202 26 30

40 305

105

1,8 Kg

500 mA

250 mA

6W

ME-201/211
26 202 30

239

40 305

105

1,8 Kg

500 mA

250 mA

6W

ME-400/410/420
265 35

40 202

40 305

1,8 Kg
105

500 mA

250 mA

6W

ME-600/610/620
525

31 35

40 550

4 Kg
105

500 mA

250 mA

6W

23

References and features


Brackets

BRACKETS
L
for outward opening doors
MBE-806 MBA-801

FOR MINI MAGLOCKS


Z
Brackets

Brackets

for inward opening doors

for glass doors

Brackets for mini electromagnetic locks


MHA-804 190

26

39

50 50

265

MBA-802 50 50

270

50

Brackets for double mini electromagnetic locks


MBE-807

Base for RF door


MRF-810 12 35

Finish selection chart


FSC-821

50 50

525 185 50

265

Wiring and voltage switching


VOLTAGE CHANGE JUMP CONNECTOR SET VOLTAGE JUMP CONNECTOR SET VOLTAGE JUMP CONNECTOR SET VOLTAGE

Correct position of voltage selection jumpers

DC POWER INPUT

DC POWER INPUT

DC POWER INPUT

JUMPERS

JUMPER

REED SWITCH FEATURES


Voltage selection pins MAXIMUM SWITCHING VOLTAGE 100 VDC (VOLTS DC) MAXIMUM SWITCHING CURRENT 0.3 A (AMPS DC) MAXIMUM CONTACT RATING 3 W (WATTS DC)

REED SWITCH CONTACTS

LED
Door properly locked

REED SWITCH CONTACTS

Door improperly locked (electric strike plate incorrectly positioned) Electromagnetic lock out of order (failure on the electric power supply)

Installation and features of the electric strike faceplate


WASHER
DOOR DOOR

WASHER
DOOR

WASHER

ARMATURE
HEX BOLT

ARMATURE SCREW HEX BOLT

ARMATURE SCREW

SCREW

JOINT

JOINT

JOINT

Fixing the armature to a steel, PVC or aluminium profile.

Fixing the armature on armoured steel doors. The steel needs to be thick enough to fasten the screw on the steel door. If the steel is not thick enough, the plate must be fastened with the hex bolt.

Fixing the armature on a wooden door.

Hex bolt Stringer

Armature fastening holes

5,5

D2 3

5,5 H

Joint Armature Washers Screw

Screw

2 Joints

Hex bolt

D1 L1 B

2 Washers
Door

Stringer

The parts shown above are delivered with each magnet.


MEASURES
HOLDING FORCE

The armature must be fastened exactly as shown above.

L
185

B
35

H
12

L1
165

D1
17

D2
9

Warning:
24

Do not fasten the center screw too tightly. The plate must be loose.

2800 N

References and features


Installation Mortise Rim

UNIVERSAL
Security device Led Reed

FOR ACCESS CONTROL & EMERGENCY EXITS


Electronic protection Holding force
1800 N 3000 N 3000 N 3000 N 3000 N x 2 3000 N x 2 6500 N 6500 N 6500 N

Timer from 2 to 8 sec.

Voltage 12 Vdc

Dual voltage 12/24 Vdc changing automatically

References
MEX-100 MEX-201 MEX-400 MEX-430 MEX-600 MEX-630 MEX-700 MEX-730 MEX-900

Dimensions
MEX-100
22 40 37 166

Packaging dimensions

Total weight

Electric consumption 12 Vdc 24 Vdc

Power

1,2 Kg
120 295

250 mA

3W

MEX-201

228

23 46 37 295 248

2,15 Kg
120

270 mA

3,3 W

MEX-400

28 52 37 295 241

2,25 Kg
120

270 mA

180 mA

3,3 W

MEX-430

28 52 37 295 241 28

2,25 Kg
120

270 mA

180 mA

3,3 W

MEX-600

52 37 120 520 482 28

4,4 Kg

270 mA

180 mA

3,3 W

MEX-630

52 37 120 520 482

4,4 Kg

270 mA

180 mA

3,3 W

MEX-700

35 70

50 160 308

4,1 Kg

270 mA

180 mA

3,3 W

265

MEX-730

35 70

50 160 308

4,1 Kg

270 mA

180 mA

3,3 W

265

MEX-900
265 40 65 50 160 308 315

4,5 Kg

270 mA

180 mA

3,3 W

25

References and features


Brackets

BRACKETS
L
for outward opening doors MBEX-180
35 40 166

FOR UNIVERSAL MAGLOCKS


Brackets

Brackets

for inward opening doors

for glass doors

Brackets for 180 Kg electromagnetic locks


MBAX-180 (3 units)
40 45 135 45

MHAX-180

135

20 40

40 26

166

Brackets for 300 Kg electromagnetic locks


MBEX-300 MBAX-300 (3 units)
50 50 240 45 52 33 240 160 50

MHAX-300

160

20 40

35

Brackets for 600 Kg electromagnetic locks


MBEX-600 MBAX-600 (3 units)
265 75 40 75 180 70

40

65 43

265

Installation and features of the electric strike faceplate


WASHER
DOOR DOOR

WASHER
DOOR

WASHER

ARMATURE
HEX BOLT

ARMATURE SCREW HEX BOLT

ARMATURE SCREW

SCREW

JOINT

JOINT

JOINT

Fixing the armature to a steel, PVC or aluminium profile.

Fixing the armature on armoured steel doors. The steel needs to be thick enough to fasten the screw on the steel door. If the steel is not thick enough, the plate must be fastened with the hex bolt.

Fixing the armature on a wooden door.

Hex bolt Stringer

Armature fastening holes

5,5

D2 3

5,5 H

Joint Armature Washers Screw

Screw

2 Joints

Hex bolt

D1 L1 B

2 Washers
Door

Stringer

The parts shown above are delivered with each magnet.


MEASURES HOLDING FORCE

The armature must be fastened exactly as shown above.

L
135,5 160 175

B
31,5 45,3 62

H
8,6 12,6 13,6

L1 D1 D2
120 140 150 10 16 16 5,6 9 9

Warning:

Do not fasten the center screw too tightly. The plate must be loose.

1800 N 3000 N 6000 N

26

WATERPROOF
References and features
Installation: Rim Chrome finish Fitting system squared Reed Electronic protection

FOR OUTDOOR APPLICATIONS


Holding force
2500 N 2500 N

IP65

Voltage 12/24 Vdc

References
ME-500 ME-510

Product especially designed for outdoor installations. IP65 approval and total protection against weathering.
References ME-500 Packaging dimensions Total weight Cable length Electric consumption 12 Vdc 24Vdc Power

40 305

105

1,9 kg

1100 mm.

500 mA

250 mA

6W

ME-510

40 305

105

1,9 kg

1100 mm.

500 mA

250 mA

6W

Dimensions

4 or 7 wires depending on the model

4 drills D=5,2 for plain faced screws (DIN 965 or similar)

Connections
ME-500
12 V dc without polarity
grey red blue yellow

ME-500
24 V dc without polarity

grey red blue yellow

ME-510

white

12 V dc without polarity NO contacts relay REED C NC

red green yellow blue black brown

ME-510

white

24 V dc without polarity NO contacts relay REED C NC

red green yellow blue black brown

Brackets for mini electromagnetic locks


5,5 D2 3 D1
50

5,5 H

MBE-806
50 265

MBE-801

L1 B

MBE-808
34 34 265

50

270 50

MBE-802

50
HOLDING FORCE

L
MEASURES

L
185

B
35

H
12

L1
165

D1
17

D2
9

2500 N

27

SHEARLOCKS
What is a shearlock and how it works

FOR SWING & SLIDING DOORS

A shearlock is an electromagnetic lock that combines magnetic and mechanical force, generating a holding power of up to 15.000N. It can be installed on all kinds of left and right handed doors (metal, wooden and glass), either horizontally or vertically. It is the ideal lock for swing doors and emergency doors equipped with panic devices. A magnetic sensor detects when the door and doorframe are aligned and makes the shearlock lock the door in place. When a sherlock is deactivated via an access control system or a button, the door is released. If, however, the door is no physically open within the T1 programmed time (closing delay), the shearlock will automatically lock the door again. Otherwise, the door can be kept unlocked for a specific time simply by interrupting the power supply. Shearlocks operate on 10-36V dc, so the installer does not have to set the voltage. They have two power connections and an adjustable delay system, which means a delay between 1 and 25 seconds for realease and locking can be set. Shearlocks are designed to be connected for instant-release buttons, traffic lights, access control systems, radio alarms and even heat and smoke detectors, in order to release the door immediately in case of fire.

Example of use
There is an attempted robbery in a department store and the thief tries to escape through an emergency door with a panic device and a shearlock. When the thief pushes the panic bar, the door will still be locked by the shearlock for the programmed time, and a warning signal can be sent to the stores emergency control center. If the system is equipped with an acoustic alarm, it will be ringing for the time the shearlock is programmed to. When the thief discovers the door is locked, he will be forced to drop the goods. Once the door is released, the stores security personnel will have to reset the shearlock to stop the alarm and reset the system.

Different installation possibilities


A) Rim

Dimensions
Rim

Model: SH100 Silver

Door only opens one way B) Mortise

Swing door

Mortise

Door only opens one way C) Glass and swing doors

Swing door

Model: SH200 Grey

Glass door A B A B

Mixed installation
A) Shearlock surface mounted B) Shearlock glass door Model: SH400

Mixed installation
A) Shearlock built-in B) Shearlock glass door Model: SH500

Shearlock for glass door Model: SH300

28

Model SH-100

Model SH-200

Warning: Maximun space between parts = 3 mm

Electrical features:
Power supply: 10-36 V dc, there is no need to set the voltage Consumption for 12 V dc 2A startup and 0,5 A operating current. Coil: Tropicalized. Autoprotection: If the closing manoeuvre is not executed correctly because there is a defect in alignment or there is an object preventing closure, the system tries to close several times. If after five attempts the shearlock cannot be closed, it remains in the open position and triggers an alarm. This prevents the product from overheating, which causes the deterioration of the product. Auxiliary relay: Inversion circuit. Maximum current: 1 A at 24 V dc. When activated, the door is locked. When deactivated, the door is released. Time delays: When locking/ aligning: 4 sec. ( adjustable from 0 to 25 sec ) When releasing/ in an emergency: 15 sec ( adjustable from 0 to 25 sec ) The adjustments can be independent from each other. Values shown are factory default settings. Additional features: Locking prevention: this connection keeps the door released, even though the power is connected. Opening delay: either through an instantaneous connection or a button with timed opening. Alarms: Intermittent alarm: The electromagnet and door plate are not aligned. Attempted forced entry. Coil malfunction. Position sensors not aligned. Alarm indications are cancelled after 15 sec. or disconnecting the power supply. Continuous alarm: Indicates the countdown to door release. Deactivates through the locking-prevention system or by disconnecting the power supply. 3 color LED indicator: Green: door released. Red: door closed. Amber: malfunction or transitory state.
Magnetic alignment sensors Power supply connection LED T2 Release-delay adjustment
FOR PANIC DEVICES

T1 Locking-delay adjustment

Power supply (10 to 36 VDC) Immediate release and reset auxiliary ( + ) Emergency release delay Auxiliary ( - ) Alarm ( - ) Relay 1 A at 24 V Transistor within the shearlocks own electronic circuit External alarm circuit: 4 + Common with the shearlock 8 - Auxiliary through the transistor in the shearlock circuit Maximum current: 350mA Pulsador apertura instantnea y reset 4 + Common with the shearlock 3 Active

29

SHEARLOCKS
Model: SH-300

FOR GLASS DOORS

Warning: Maximum space between parts = 3 mm

Installation instructions
1) Ensure the separation between the two glass plates (fixed part and moving part) is 6,5 mm or more. 2) Install the two parts of the shearlock so they are perfectly aligned and parallel. 3) For the sensor to detect when the door is closed, the separation between the two parts of the shearlock should not exceed 3 mm.

SET SCREW FOR BERING STRIP FOR THE GLASS (2 units)


M6 allen key 3 mm spanner

LOCKING

M6 allen key (2 units) 3 mm spanner

BERING STRIP FOR THE GLASS

INSTRUCTIONS
1. 2. 3. 4. 5.

Adhesive strip with protective backing

Remove the protective backing. Put the bracket in place. Remove the two locking screws. Use the set screw to push the bearing strip forward until it exerts pressure on the glass. Insert and tighten the locking screws until they lock into the set screws.

Installation example

Power supply

Hydraulic spring Traffic light

Coded access control AC-100


Traffic light Power supply from 10 to 36 Vdc Maximum current: 2,5 A at 10 V Operating current: 0,5 A at 10 V Stabilized direct current Observe connection polarity

30

ACCESSORIES

new new

TRAFFIC LIGHTS for access control systems DOOR LOOPS for any kind of installations DOOR CONTACTS for any kind of installations PROVISIONAL LATCH for construction works POWER SUPPLIES for any kind of installations RIMTOPLOCK for door entry and access control systems
31

new new

TRAFFIC LIGHTS
10-24 V ac/dc (flashing or steady light mode)

new

FOR ACCESS CONTROL SYSTEMS

10-24 V ac/dc (flashing or steady light mode plus audible warning device)

2 LEDS (Red and green)

2 LEDS (Red and green) + push button

2 LEDS (Red and green) + audible warning device

2 LEDS (Red and green) + push button + audible warning device

TLX001

TLP002

TLB001

TLB002

Jumper operation

Electrical connection

Non polarized power supply 10-24 Vac / dc

Green LED contact COM Red LED contact

without jumper The audible warning device and the LED light remains in flashing mode.

with Jumper the audible warning device and the LED light remains in steady mode.

Traffic lights dimensions

Box dimensions

40

4,5

80

11

40 129,5 110 14 18,6 26 22

32

40

80

DOOR LOOPS
References and features
Model Diameter EFX150 14,5 mm

new

FOR ANY KIND OF INSTALLATIONS

Finish color

Flex tube lenght

Total lenght

Steel

150 mm

250 mm

SFX250

14,5 mm

Steel

150 mm

250 mm

SFX420

14,5 mm

Steel

320 mm

420 mm

SFX600

14,5 mm

Steel

500 mm

600 mm

47

BFX300G

14,5 mm

Grey box Steel Flex tube

200 mm

300 mm

39

22

BFX500G

14,5 mm

Grey box Steel Flex tube

400 mm

500 mm

47

BFX300B

14,5 mm

Brass box Steel Flex tube

200 mm

300 mm

39

22

BFX500B

14,5 mm

Brass box Steel Flex tube

400 mm

500 mm

DOOR CONTACTS
Dual electrical contacts
DDC002
58 6 11 70

FOR ANY KIND OF INSTALLATIONS

Electrical features
Maximum voltage: 24 V ac/dc Maximum intensity: 1,5 A. ac/dc
11 13

33

PROVISIONAL LATCH
For faceplates located on building sites

new

FOR CONTRUCTION WORKS

During construction work, it is possible to install a provisional latch CSR 001 that will leave the faceplate ready for the installation at the corresponding electric strike. The latch replacement CSR 001 allows to keep the doors closed during the construction process, and is supplied with the 3 mm adjustable latch.

The CSR001 provisional latch can be installed in all OPENERS & CLOSERS faceplates

Provisional latch CSR001 (3mm adjustable)

Dimensions
12,6 12,6 5,4

faceplate 03

faceplate 03 + CSR001

44,7 52,3

34

POWER SUPPLIES
References and features
Power supplies at DC current Input Voltage
230 V 50/60Hz 230 V 50/60Hz 230 V 50/60Hz 230 V 50/60Hz 230 V 50/60Hz 230 V 50/60Hz

FOR ANY KIND OF INSTALLATIONS

Output Voltage
12 V dc 24 V dc 12 V dc 24 V dc 12 V dc 24 V dc

Output Current
6 A dc 3 A dc 6 A dc 3 A dc 3 A dc 1,5 A dc

Stability
3% 3% 3% 3% 3% 3%

Protection Degree
IP20 IP20 IP20 IP20 IP20 IP20

Power
80 W 80 W 80 W 80 W 30 W 30 W

Battery Charge
yes yes yes yes

Battery

Capacity

References
PS 901* PS 902*

12 V dc 24 V dc

7 Ah 4 Ah

PS 905** PS 906** PS 907* PS 908*

High efficiency (77-87%) switching power supplies. Temperature operation between 0 - 40C Single output, over voltage, over heating and short circuit protection. Double function: power supply and batteries charging on line system, with complete discharge protection

Power supply at AC current


230 V 50/60Hz * ** 12 V ac 1,5 A ac IP20 18 VA PS 903*

Finish DIN rail 35 x 7.5 ( DIN 500 22 ) 4 terminals for 2 electromagnetic locks each, with switches and operation warning light controls.

PS 901

PS 907

PS 905

PS 902

PS 908

PS 906

PS 903

35

RIMTOPLOCK
General operation:
CE-104

FOR DOOR ENTRY & ACCESS CONTROL SYSTEMS

When the door is aligned with the frame, the magnetic detector located at the (front) lock box, blocks the door. Once the lock is released, and during the scheduled opening time, the lock makes an intermittent warning sound. After a scheduled time, the lock blocks automatically. An acoustic alarm warns when the door is not properly closed.

Features and functional description


Mechanical opening handle Push button for electrical opening External cylinder for key opening Reversible, 60 mm cylinder 12 V dc power supply 500mA energy consumption 350.000 guaranteed openings EXIT: ENTRY: 1) Access control opening 2) Key opening 1) Electrical opening using the red push button 2) Electrical opening using access control 3) Mechanical opening using lock handle

IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit using lock handle

CE-105

Features and functional description


The lock remains in permanent unblock position pressing the green button. The lock becomes operative again with a second press, which cancels the permanent unblock. Mechanical opening handle Push button to lock / unlock permanently External cylinder for key opening Reversible, 60 mm cylinder 12 V dc power supply 500mA energy consumption EXIT: ENTRY: 1) Access control opening 2) Key opening 1) Electrical opening using access control or pressing the button 2) Mechanical opening using lock handle

CE-106

350.000 guaranteed openings

IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit using lock handle

Features and functional description


Mechanical opening handle External cylinder for key opening Reversible, 60 mm cylinder 12 V dc power supply 500mA energy consumption 350.000 guaranteed openings EXIT: ENTRY: 1) Access control opening 2) Key opening 1) Electrical opening using access control or pressing the button 2) Mechanical opening using lock handle

CE-109 Features and functional description


Internal and external cylinder for key opening Reversible, 60 mm cylinder 12 V dc power supply 500mA energy consumption 350.000 guaranteed openings

IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit using lock handle

ENTRY:

1) Access control opening 2) Key opening 1) Electrical opening using access control or pressing the button 2) Mechanical opening using keys

EXIT:

VCX-100

Rain-protection steel visor

IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit with keys

94 42

Dimensions and electric diagram

Lock Motor
100 96 80

Lock Motor

Green
40

Exterior push button

Green Red

Push button

Red
Lock switch push button

129,5

58

Door sensor

Door sensor

55

41

a
126

Blue (-) Red (+) 12V dc

36

Warning:

a The distance between the electric strike and the front box should be 5 mm.
Distance plastic controller included.

Das könnte Ihnen auch gefallen