Catalogue HY11-2500/UK Direct-Operated Proportional Pressure Valve

Characteristics / Ordering Code Series RE06M*T

The proportional pressure relief valve series RE06M*T


allows variable adjustment from pmin up to nominal pres-
sure. In case of power breakdown the valve is depressur-
ized.

Features
• Direct-operated pressure relief valve
• On-board electronics
• Ramp line adjustment
• Characteristics linearized
• Very low pressure adjustment of pmin
• Subplate mounting acc. to ISO 6264
• 4 pressure stages
4
• 2 pressure inlet ports A and P

Ordering code

RE 06 M T 2 V 1 0

Proportional NG06 Mounting Pressure On-board FPM Normaly Electronic Electronic Series
pressure pattern range electronics seal open design attachment
relief valve ISO 6264

Code Pressure range Code Electronic design


10 105bar Voltage input
17 175bar F 0...+10V with refer-
ence output +10V
25 250bar
35 350bar R Current input
4...20mA

RE06M_T.PMD RH

4-33 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Direct-Operated Proportional Pressure Valve
Technical Data Series RE06M*T

General
Nominal size [DIN/CETOP] 06 / 03
Interface ISO 6264
Mounting position as desired, horizontal mounting prefered
Ambient temperature [°C] -20...+80
Weight [kg] 2.2
Hydraulic
Operating pressure [bar] Ports A and P up to 350, connection T depressurized, solenoid up to 210
Pressure stages [bar] 105, 175, 250, 350
Volume flow [l/min] See p/Q curves
Pressure medium Hydraulic oil according to DIN 51524 ... 525
Viscosity, recommended [mm²/s] 30 ... 80
maximum [mm²/s] 12 ... 380
Pressure medium temperature
recommended [°C] 30 ... 50
maximum [°C] -20 ... +60
Permitted contamination ISO 4406 (1999), 18/16/13
Linearity [%] See curve
Repeatability [%] <±1
4 Hysteresis
Manufacturing tolerance
[%]
[%]
±1.5 of pmax
±2.5 of pmax
Electrical
Duty cycle [%] 100 ED
Protection class IP54 at DIN 40050 (plugged and mounted)
Supply voltage [V] 14.5...30
Ripple in supply voltage [%] Max. 5
Current consumption [A] 2.8
Ambient temperature [°C] -20...+80
Input range
voltage input [V] 0...+10 max. / 10kOhm
current input [mA] 0...+20 / 500Ohm
Adjustment range of ramp time [s] 0...5
Installation cross-section Min. 1mm² shielded
Cable length [m] Max. 50
Plug connector No. 5004072; 6pole + PE / connector DIN 43563 / cableØ 8...10mm

RE06M_T.PMD RH

4-34 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Direct-Operated Proportional Pressure Valve
Characteristic Curves Series RE06M*T

Command/pressure curve

pmin/Q curves
4

p/Q curves

RE06M_T.PMD RH

4-35 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Direct-Operated Proportional Pressure Valve
Electronics Series RE06M*T

Block diagram

Connector wiring diagram

RE06M_T.PMD RH

4-36 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Direct-Operated Proportional Pressure Valve
Dimensions Series RE06M*T

Surface finish Bolt kit DIN912 12.9 NBR FPM

BK-M5x30-4pcs 8.1 Nm SK-RE06MNT SK-RE06MVT

Mounting pattern ISO 6264-03-04-*-97

RE06M_T.PMD RH

4-37 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Direct-Operated Proportional Pressure Valve