888.902.6111 intellirentco.com
Anyone can rent you a piece of equipment, but can they do it the intellirent way; pre-selection of the right equipment, in-stock, delivered on time & field ready, with application support? intellirent can.
We rent electrical test and measurement equipment from Doble, Dranetz, Fluke, High Voltage, HV Diagnostics, Manta, Megger, Omicron, Raytech, Vanguard and many more. Thorough understanding of field applications. Equipment consultations before you rent to ensure you get the appropriate test equipment for your application. Delivered field ready and complete with manuals, test leads, charged batteries, even laptop and software set up if required. Our equipment is tested in real world conditions as part of the intellirent conditioning and pre-shipment program. Worldwide logistics and transportation.
Table of Contents
Power Analysis and Data Acquisition Relay and Protection Test Equipment Transformer Test and Diagnostic Equipment Switchgear and Circuit Breaker Test Equipment Cable and Bus Test Equipment Battery Test Equipment Ground Test Equipment Meters and Meter Test Equipment Inspection Equipment Motor and Rotating Apparatus Test Equipment Electrical Safety and Hospital Test Equipment Process Calibration Equipment Index by Application Index by Manufacturer 2 12 18 30 54 66 68 70 78 84 86 88 94 96
contact information
604 Henrietta Creek Suite 400 Roanoke, TX 76262 T 888.902.6111 T 972.317.0479 F 817.491.0068 intellirentco.com info@intellirentco.com
Quick Communications and Configuration Using Bluetooth Enabled Device Provided by Intellirent Threshold Free Setup Apply Thresholds After Monitoring Is Complete Using Flukes Intuitive Power Analyze Software Five Voltage and Five Current Inputs Enable Separate Ground and Neutral Motoring Data is Recorded to Internal Flash Memory With 1GB of Storage Capacity Monitors All Power, Energy, Distortion and Power Quality Parameters with Harmonic Measurement to The 50th Order Provided by Intellirent with Appropriately Ranged Current Probes (Pictured Below)
Intellirent Provides a Comprehensive Selection of Current Probes for Use with Fluke Power Quality Analyzers. Current Probes to Support Your Specific Application are Included with the Selected Power Quality Analyzer. Fluke 3005D Rigid Probe with 3/4 Jaw Opening .01 5A Range 1% RDG 0.5% FS Accuracy Fluke 3014 Rigid Probe 3/4 Jaw Opening 0.1 40A Range 1% RDG 0.5% FS Accuracy Fluke 3110 Flexible Probe, 24 2-100A Range 1% RDG 0.15% FS Accuracy Fluke 3210 Flexible Probe, 24 20-1000A Range 1% RDG 0.15% FS Accuracy Fluke 3310 Flexible Probe, 24 100-5000A Range 1% RDG 0.15% FS Accuracy
888.902.6111
www.intellirentco.com
High Speed Monitoring, Data and Waveform Capture, up to 1 Microsecond/Channel, of All Power, Energy, Distortion and Power Quality parameters Simple Setup and Configuration Through Touchscreen Interface Automatic or Wizard Configuration Automatic Circuit Type Verification to Minimize Erroneous Data Recording Sessions Comprehensive Control of Thresholds, Triggers and Monitoring Parameters Powerful Reporting Software, DranView Professional or DranView Enterprise, for In Depth and Comprehensive Reporting and Analysis Current Ranges From .01 to 6000A with Available Current Probes (Pictured Below) Dranetz PX4-400 model Extends Frequency Measurement Range to 400 Hz
Intellirent Offers a Comprehensive Selection of Current Probes for Use with the Dranetz PX5. Current Probes to Support Your Specific Application are Included With Your Rental.
Dranetz TR-2510 0.01-10A (3/4 Jaw) Rigid Current Probe Dranetz TR-2500 1-500A Rigid Current Probe (1 3/16 Jaw) Dranetz 3000XL24 300/3000A 24 Flexible Current Probe Dranetz 3000XL36 300/3000A 36 Flexible Current Probe Dranetz 3000XL48 300/3000A 48 Flexible Current Probe Dranetz 6000XL24 600/6000A 24 Flexible Current Probe
Dranetz 6000XL36 600/6000A 36 Flexible Current Probe Dranetz 6000XL48 600/6000A 48 Flexible Current Probe Proflex ACP 3000 Tridra 300/3000A 24 Three Phase Flexible Current Probe
Hand-Held Monitoring, Data and Waveform Capture for AC or DC Circuits up to 256 Samples/Cycle Large Color Display Includes Direct Access to Waveforms, Transients, Harmonic Bar Graphs, Events, Trend Recordings, and Power Statistics Large 2GB Removable Memory Card Enables Extended Recordings of Any Power Parameter, Harmonics, Transients, Waveform Distortion, Crest Factors, Transformer K Factor, Flicker and Phase Unbalance Backup Battery Life of 8 Hours Available With a Wide Selection of Current Probes, From 1A (Rigid) up to 6500A (Flexible)
Hand-Held Monitoring, Data and Waveform Capture for AC or DC Circuits up to 256 Samples/Cycle Large Color Display Includes Direct Access to Waveforms, Transients, Harmonic Bar Graphs, Events, Trend Recordings, and Power Statistics Provided With DataView Software for Simple Report Generation Available With a Wide Selection of Current Probes, from 240A (Rigid) up to 6500A (Flexible)
888.902.6111
www.intellirentco.com
Measures and Records Three Phase Power, Energy, Power Quality and Harmonics Measures Voltage to 600V, Current to 3000A with Included 3000A Flexible Current Probe, Peak Demand, Frequency and Power Factor Event Sampling Includes Sags, Surges, Harmonics (THD and Individual to 49th) Calculates kW, VAR, VA, and kWh Readings can be Viewed During the Recording, After the Recording is Complete on the LCD or After Downloading Into the Included Download Suite Software Charting and Exporting Recorded Results Is Simple and Convenient No Software Key or Registration Required Optional .5-100A Current Range with Rigid Current Probes (Picture Below) Battery Backup Records for Six Hours Includes Phase Sequence Indicator, Ground Tester, and 1kV Megohmmeter USB Communications Facilitates Simplified Download Provided by Intellirent with Download Suite Software for Graph and Table Generator or Export to MS Excel
Range 5-1000A Current Probe for Dm-II Pro or DM-III 30-3000A Flexible Current Probe for DM-III Dual Range, 300 or 3000A for DM-II Pro .1-100A Current Probe for Dm-III
Measures and Records Power Three Phase Power and Energy Measures Voltage to 600V, Current to 1000A With Included 1000A Rigid Current Probes and Power Factor Calculates kW, VAR, VA, and kWh User Selectable Sample Rate Permits Recording Periods from Hours to Months Readings can be Viewed During the Recording, After the Recording is Complete on the LCD or After Downloading Into the Included Download Suite Software Charting and Exporting Recording Results Is Simple and Convenient Optional 3000A Current Range with Flexible Current Probes
Comprehensive Recording of All Parameters 15 inch Touch Screen Display Real Time Calculations, Continuous Recording and Event Logging Sample Rates From Once Per Minute to 200,000 Per Second Per Channel Logged Events for Voltage Include Interrupt, Sag, Swell, Transient, Frequency, THD, Individual Harmonics/Interharmonics and Unbalance Logged Events for Current Include Transient, RMS Thresholds, THD, Individual Harmonics/Interharmonics and Unbalance Logged Events for Power Include PF, kVA, kW and kVAR Optimal for Generator Load Step Tests or UPS Commissioning Provided by Intellirent With AstroView X Software and Preconfigured Laptop Computer if Desired
Astromed Modules
Signal Non-Isolated Differential Input Module Isolated Single End Voltage Module Isolated Bridge Input Module Isolated Single End Higher Voltage Module Universal Therocouple Input Module Isolated Single End Higher Voltage Module
Range +/- 5V (10V FS w/ 0 Offset) 250V AC/DC +/- 2V 600V AC/DC J, K. E, T, N, B, R or S 250V AC/DC
Astromed Modules
ITCU IHV3
888.902.6111
www.intellirentco.com
Portable and Lightweight (22 Lbs) 15 Touch Screen Display Real Time Signal Testing Including Window, Slope/Level and Event Sample Rates from Once Per Minute to 200,000 Per Second Per Channel Single Ended Voltage Monitoring with a Max Measuring Voltage of 600V RMS with IHV2 Module Differential Voltage Recording with a Max Measuring Voltage of 2 to 4 VFS with IBR1 Module Type J, K, T, E and N Thermocouple Measurements RTD Measurements Optional Onboard Thermal Printer Provided by Intellirent with AstroView Software
Portable and Lightweight (27 Lbs) 17 Touch Screen Display Real Time Signal Testing Including Window, Slope/Level and Event Sample Rates From Once Per Minute to 200,000 Per Second Per Channel Video Snapshot Recording Rates up to 1 Frame Per Second Single Ended Voltage Monitoring with Maximum Input of 250V AC or DC Differential Voltage Recording with a Maximum Input of 40Volts Bridge Measurement with a Max Input Voltage of 40Volts Differential Type J, K, T, E and N Thermocouple Measurements Onboard 73GB Harddrive Optional Onboard Thermal Printer Provided by Intellirent with AstroView Software
AC or DC Rigid and Flexible Current Probes with mV or mA Outputs for Data Acquisition or Meter Applications
Model AEMC MN103 AEMC MN254 AEMC SL201 AEMC MR410 Amprobe CT600 AEMC MR521 AEMC SR600 AEMC JM865A Fluke i2000 Flex
Range 1mA 10A AC, 1A-100A AC, mV Ouput 0.1A to 240A (Duane Range), mV Output 50mA 150A AC or 50mA to 150A DC, mV Otuput 1A-400A AC or 600A DC, mV Output 0.1-600A AC or DC, mV Output 0.2 to 1000A AC or 0.5 to 1500A DC, mV Output 0.1A to 1200A AC, mA Output 1A to 3600A AC, mA Ouptut Flexible, 0.2 to 2000A AC, mV Output
Provided by Intellirent as a Complete System with A Fluke DAQ Pre-Configured Laptop Computer, Appropriate Input Modules and Networking Configuration Components Prewired with Input Signal Leads as Required Measure up to 120 Signals Per Unit or 720 Signals by Combining 2686 Units Sampling Rate Adjustable from 1000 Readings/Second to 1 Reading/Hour Measure AC or DC Voltage, Resistance, Frequency, RTD and Thermocouples, Thermistor and Current (including 4..20 loops) Simple Configuration and Setup
Data Acquisition Systems from Intellirent can be Configured for Measurement of: Current Voltage Resistance Frequency Phase Angle Power Factor Temperature (RTD and TC) Pressure Flow (Liquid or Gas) Vibration RPM Sound Level Light Level
888.902.6111
www.intellirentco.com
Measure Three Phases with Neutral at 200 kS/s on Each Channel Simultaneously Available From Intellirent with a Wide Variety of Current Probes from 5A for Monitoring Secondaries to 5000A Flexible Current Probes (Picture Above) Measure and Record: Voltage (AC and DC) to 1000V Current (AC and DC) to 5000A Peak Voltage and Peak Current Crest Factor Frequency Dips and Swells Harmonics Power and Energy Flicker Unbalance Internal Memory Records 5 Readings/Second Continuously Per Channel Records up to 1800 Min/Max and Average Points for Each Reading Provided by Intellirent with FlukeView Software Interharmoics, Advanced Energy, Transient and Inrush are Available on Fluke 435 Model
Measure and Trend Single Phase Voltage to 1kV, Current to 3000A, Frequency, Power Harmonics, Voltage Sags, Transients and Current Inrush Record Two Selectable Parameters for up to 16 Days Internal Measurement of 20 Parameters Provided by Intellirent FlukeView Software
Measure Current to 400A and Voltage to 1kV at 40 MHz High Resolution Monochrome Display Sample Rate of 25 MS/s Divisions of 5mV 500V Scope Record Mode will Record 512 min/max Points Per Input Internal Memory of up to 20 Screens and Setups Provided by Intellirent with FlukeView Scopemeter Software
Ten Simultaneous Measurements of Frequency, Phase Angle, AC/DC Voltage, AC Current (200A Max), Power Factor, Watts, and VARS. On Board Timer Measures Cycles or Seconds Based on State or Contact Changes Lightweight and Simple to Operate Phasor Display of AC Values Battery or Line Powered
Light Weight (13 Lbs) and Simple to Use with Intuitive Controls Battery or Line Operated Measure Voltage, Current (100A Directly or Higher With Optional CTs), Phase Angle, Power, Reactive Power, Frequency, Harmonics, and Time (Seconds or Cycles) Onboard Datalogger Records Events Displays Three Phase Voltage, Current, Phase Angle, Power, Reactive Power, Power Factor, and Frequency Simultaneously. Variable PT and CT Ratios for Display of Primary Values
Provided With Three Open Sensor CTs Suitable For Use On 69kV Systems Sensor Opening of 1.3 +/-1% Accuracy to 1000A Provided With Softlink Software and IrDA Communications Cable
10
888.902.6111
www.intellirentco.com
Measure Current to 4000A and Voltage to 1kV at 200 MHz High Resolution Color Display Sample Rate of 1 GS/s Divisions of 2mV 100V ScopeRecord Mode will Record 27,500 Points Per Input Internal Memory of up to 15 Screens and Setups Provided by Intellirent with FlukeView Scopemeter Software
Small and Lightweight (less than 1 Lb) Capable of Operation from 100 to 600V with a Frequency Range from 45 to 65 Hz Powered by Circuit Under Test
Tests Electrical Equipment and Medical Instruments To AAMI, UL and NFPA Codes Measures Leakage Current, Voltage and Resistance Insulation Tests to 100V Open Ground and Neutral Test Switches Line, Voltage, Polarity and Receptacle Ground Test Polarity Switch for Test Receptacle Includes Isolated Power System Tests and Line Isolation Test
11
Simple Manual Controls Provide Access to Advanced Functions without a Computer On Board Color Display Indicates Vector Displays, Intuitive Control Menus, and Complex Poly-Phase Output Signals Standard Configuration Provides Three AC/DC Voltage Outputs, Three AC/DC Current Outputs, and a Single DC Voltage Output Twelve Channels of Status Inputs and Four Digital Outputs for Detailed Interaction with Relays Under Test USB and Ethernet Interfaces Extensive on Board Help Screens with Tutorials and Connections Diagrams Vertical Configuration Minimizes Footprint in Small Control Rooms and Generator Protection Panels Configure both Pre-fault and Fault Settings for Dynamic Relay Testing or Utilize Static Relay Testing Methods Compact and Lightweight (49 Lbs) Low Level DCV/mA Inputs for Calibrating Transducers Currents can be Paralleled for High VA Output Optional GPS Antenna for End-To-End Testing Comtrade (.cfg) and Waveform Playback Capable
12
888.902.6111
www.intellirentco.com
High Versatility and Functionality For All Generations and Types of Protective Relays Standard Configuration Includes Six Current Outputs (in Three Phase Mode, 64A/860VA Per Channel or One Channel at 128A/1000VA) for Maximum Flexibility and Range of Applications Optional GPS or IRIG-B Accessories for End-to-End Testing Simulates Transient Faults, Power Swing, CT Saturation, CB or Rogowski Coil Simulation Transient Playback Through Comtrade, PL4 (EMTP), etc. Ten Binary Inputs (Dry/Wet) On-Board 10 Channel Recorder for Typical Power Values, Transients, Trend Recordings and Harmonic Analysis Provided by Intellirent with a Laptop Preconfigured with Test Universe Software for Automated Testing or CMControl for Manual Testing Lightweight (37 Lbs) and Easily Transported In Intellients Ruggedized Case
13
Three Convertible Channels (300V or 15A) and Three 60A Channels 10 Binary Inputs and 6 Binary Outputs Bluetooth, USB or Ethernet Communication Between SMRT36 and Computer Optional Chaining SMRT36 Units Together for up to 24 Outputs Meggers Smart Touch View Interface (STVI) Provides Simple Touchscreen Graphical Interface for Testing Most Relays Realtime Display of Phasor and Values Variable Battery Simulator High Current Output Suitable For Modern and Electromechanical Applications Complex Impedance Testing Simplified with Built in Relay Library On Board Storage of Test Results in PowerDB Format or Immediate Export To Optional Computer Controller Compact and Lightweight (26 Lbs)
Simple and Intuitive Front Panel Interface High Current/VA Outputs Permit Testing of Most Single Phase Relays and Some Three Phase Devices Two Voltage Outputs and One Current Output, Plus Variable DC Power Supply and Flexible On-Board Timer Continuous Phase Shift Function Enables Testing of Directional Relays or Automatic Reclosing Devices Flexibility To Perform Varied Applications, Including Plotting of Excitation Curves, CT and PT Ratio Testing, Burden and Impedance Measurement, Polarity Tests and Manual Secondary Injection of Current and/or Voltage
14
888.902.6111
www.intellirentco.com
Fully Automated Testing Through Protest Test Plans Simple, Manual Testing Through Control Panel Software Provided by Intellirent with a Protest Configured Laptop Computer and Appropriate Leads and Connectors for Most Relay Testing Applications Standard Configuration Includes Three 300VAC Outputs and Three 30Amp AC Outputs Simultaneously Software Adjustment Permits a Variety of Other Configurations, Including Four Voltages and Four Currents, a Single Current at 675VA and Much More. Variable Phase Angle, Frequency Generation, Phase Shifting and on Board Battery Simulator for Energizing Relays Before Control Power is Available Includes Doble TransWin Software for Comtrade Config File (.cfg) Playback Optional Satellite Antenna Provides for End-To-End Testing Optional Doble F6300 Increases Current Output
15
Multiple Output Configurations, Including One Voltage and One Current, Two Voltages, or Two Currents Voltage Output Up to 300VAC (Phase to Ground) Onboard Timer, Phase Shifter and Frequency Generator Current Output to 26Amps AC Continuous Simple Front Panel Control Optional Doble F2010 Mini Controller Available for Fine Frequency Adjustments and Remote Control Optional Computer Control Available Via Protest Software
Multiple Output Configurations, Including One Voltage and One High VA Current or Two Currents Voltage Output Up To 300VAC (Phase to Ground) or 424VDC Continuous Onboard Timer, Phase Shifter and Frequency Generator Current Output up to 90 Amps AC or 60 Amps DC Continuous Simple Front Panel Operation Optional Doble F2010 Mini Controller Available for Fine Frequency Adjustments and Remote Control Optional Computer Control Available Via Protest Software
Permits Flexible Hand Held Control of Doble F2000 Series Units Precisely Adjust Voltages, Current, Phase Angle and Frequency Enables Adjustment of Any Two Values for Dynamic Testing
16
888.902.6111
www.intellirentco.com
Model specific accessories, including test jacks or paddles Communications accessories such as signal converters and interface cables Software for relay interface and pre-developed test plans and macros to suit the relay being tested Assistance with relay settings analysis, including settings development services
GE 12XA12A1
Doble F6895
Test set accessories, including GPS antennas and application specific lead sets Calibrators and signal generators for temperature (RTD/TC), frequency, mV or 4-20mA loops
Signal Generators
17
Rugged Construction for Field Use with Laboratory Accuracy and Precision Industry Standard for Testing Electrical Apparatus such as Transformers, Generators, and Cables Evaluates Integrity of High Voltage Substation Apparatus by Measuring Power Factor/Tan Delta Measures Capacitance to Evaluate Physical Changes Measures Accurately in High Electrostatic and Electromagnetic Conditions Measures Excitation Current to Evaluate Transformer Magnetizing Circuit Line Frequency Modulation Technology Eliminates Substation Interference Automated Testing Procedures Through DTA or Manual Through M4000 Clipboard Provided by Intellirent with an M4000 Clipboard and DTAF Pre-Configured Laptop, Safety Strobe, Temperature / Humidity Transmitter Internal Field Calibration Reference Ensures Accurate Testing Built in Diagnostics Provide Information on Instrument Status Output Current to 300mA at 10kV (Total Output Power 3kVA) for Better Replication of In-Service Conditions Optional Type C Resonator Increases Output Capacity Optional M4110 Available for Measuring the Impedance of the Apparatus Under Test Optional M4140 Available for Measuring Capacitance of Capacitor Banks Optional Liquid Insulation Test Cell For Measuring Insulating Characteristics of Oil Optional TTR Capacitor for Measuring Transformer Ratio
Performs Short Circuit Impedance Tests on Transformers Simple to Connect and Operate Using M4100 Automated Testing Procedures Provided with Software Integrated with M4000/DTA Preconfigured Laptop Computer
18
888.902.6111
www.intellirentco.com
Analyzes the Winding Relationship Inside a Transformer Optimal for Winding Movement Assessment After Transport, High Magnitude Faults, and Lightning Strikes Simple Hookup and Automated Testing Results Management Software for Establishment of Baseline Data and Trending Provided by Intellirent with a Preconfigured Laptop
Megger CB-100 Low Voltage Capacitance and Insulation Power Factor Test Set
Lightweight (21 lbs) and Portable Output of 26V at 100Hz Minimizes 60Hz Interference Performs UST and GST Configuration Testing Direct Reading of Capacitance and Dissipation Factor Simple Manual Interface Optimal for Transformer Dry Out
Megger CB-100 Low Voltage Capacitance and Insulation Power Factor Test Set
19
Reliably Identifies Moisture Content in Oil-Paper Insulation for New or Aged Insulation Provided with Detailed Connection Diagrams for Most Measurement Scenarios Integrated Database Grades Moisture Level (No Expert Knowledge Required) Provided by Intellirent With DIRANA Preconfigured Laptop Computer Effective Tool for Complete Transformer Maintenance, or Diagnosis of Motor, Cable or Instrument Transformer Insulation.
Detects Winding Defects and Faults in Transformer Core Appropriate for Complete Transformer Maintenance or Following a Short Circuit, Transport, Transient Fault Currents, Considerable Change In Monitored Values (I.E., DGA). Repeatable and Trendable Results With Advanced Connection Technique Powerful and Intuitive Omicron FRAnalyzer Software Enables Simple Comparison of Data and Report Generation Expert Assistance Available Provided by Intellirent With FRAnalyzer Preconfigured Laptop Computer and Complete Connection Kit Battery Operated
20
888.902.6111
www.intellirentco.com
Quickly Identify Presence and Severity of Partial Discharge in Electrical Apparatus Baselines Partial Discharge Activity to Direct Maintenance Activities Measures Surface Partial Discharge As Numerical dB Values and Measures Internal Partial Discharge as TEV Values Gathers Partial Discharge Data For Comparison and Trending Automatically Grades Condition of Transient Earth Voltages (TEV) and Ultrasonic Values For Immediate Analysis Simple and Intuitive Operation Though Menu Driven, Multifunction Display Provided by Intellirent With UltraDish Parabolic Waveform Concentrator, Flexible Sensor, External Microphone, Surface Contact Probe, and Headphones for Surface, Internal or Overhead Applications
21
Provides for Automated Testing of Power Transformers, CTs, VTs, Resistance Testing and More Optimal For Emergent Requirements or Remote Applications - One Device Replaces Multiple Instruments Onboard or Computer Driven Test Plans For Push Button To Start Automation Automatic Results Storage and Report Generation Stand Alone Functionality For: Ratio, Burden and Polarity, Phase and Magnitude Error, Excitation Curve, Winding Resistance, Secondary Burden and Dielectric Withstand Tests for CTs and PTs Ratio, Winding Resistance, Tap Changer Testing, Excitation Current, Short Circuit Impedance Measurement and Leakage Reactance Testing of Transformers Contact Resistance, Winding Resistance, Ground Resistance or Measurement of Complex Impedances Single Phase Testing of Primary and Secondary Relays (Including Over Current, Over Voltage, Undervoltage and Frequency Relays
Optional TD-1 Performs Tangent Delta and Power Factor Tests Flexible AC and DC Power Supply to 2kV AC, 400A DC, 800A AC Optional CP CB2 Boosts Current Output to 2000A AC USB, Serial or Ethernet Interface Optional CPOL Permits Polarity Verification at Multiple Test Points
22
888.902.6111
www.intellirentco.com
Controlled by The Omicron CPC-100 For Complete Capacitance and Tangent Delta / Power Factor Measurement Measures Capacitance, Dissipation Factor, Power Factor, Power, and Impedance 12kV Output Onboard or Computer Driven Test Plans For Push Button To Start Automation Through CPC-100 Available With Integrated Hand Truck for Simplified Transport
Integrates with Omicron CPC-100 For Comprehensive Current and Voltage Polarity Verification Throughout System CPC-100 Injects a Specialized Signal Over Primary Circuits for Red/Green Polarity Indication on Portable CPOL Faster Than Traditional Methods and Documented on CPC-100 Polarity Check Test Card
Integrates With Omicron CPC-100 For a Increased Output of up to 2000A AC. Provided With Short or Long Output Leads For Varying Applications Output of 2000A at 2.45V for 25 Seconds at 15-400Hz
23
50A Output for Testing the Largest Transformers with Repeatable Readings Automatically Demagnetizes Winding upon Test Completion 2 Measurement Channels and Onboard Printer Convenience Bright Touchscreen Interface or Full Computer Control Color Coded Connections and Simple interface for Fast Familiarization Automatic Discharge Circuit Optional Heat Run Software and Three RTD Inputs
Raytech WR-14
15A Output for Testing Most Transformers with Repeatable Readings Battery or Line Powered 2 Measurement Channels and Onboard Printer Convenience Bright Touchscreen Interface or Full Computer Control Color Coded Connections and Simple interface for Fast Familiarization Automatic Discharge Circuit Onboard Storage of Results Lightweight (21 Lbs)
24
888.902.6111
www.intellirentco.com
Automatic Current Ranging from 10 mA to 40 A 2 Measurement Channels On Board Printer for Immediate Results Documentation Internal Memory Stores 48 Records of 63 Readings Automatic Discharge Circuit Lightweight (30 Lbs) Simple Menu Driven Operation
Automatic Current Ranging from 10 mA to 10 A 2 Measurement Channels Automatic Discharge Circuit Lightweight (27 Lbs) Simple Menu Driven Operation Vanguard WRM-10P Model Includes On Board Printer
25
Simple Transformer Type Selection Measures Voltage/Turns Ratio, Current and Phase Displacement Internal Storage of 100 Test Results with RS-232 Interface Ratio Measurement from .08 to 13,000 Turns Optional Raytech T-Rex Measures Phase Relationship of Windings while Three Phase Voltage is Applied
Fully Automatic with Seamless Integration to Raytech TR-SPY Mark II Measure Phase Relationships of Transformer Windings while Applying Three Phase Voltage Especially Useful when Measuring Ratio of Zig-Zag Type Transformers
Lightweight (7 Lbs) and Battery Operated Measures Transformer, PT or CT Ratio and Polarity Raytech TR-1P Includes Onboard Printer Internal Storage of 50 Test Results Ratio Measurement from 0.8 to 4,000 Turns
26
888.902.6111
www.intellirentco.com
Simplified and Convenient Touchscreen User Interface for Test Setup, Results Display and Documentation Storage USB Interface For Documentation and Test Plan Transfer Automated Test Voltage Selection Automatic Measurements of Voltage, Turns Ratio, Current and Phase Displasement Automatic Phase Vector Detection Includes Percent Error Vs. Nameplate Data For Secondary and Tertiary Windings Onboard or Computer Based User Configured Transformer Test Plans Graphical Tap Changer Display Tap Changer Interface (Input and Output) Optional Raytech T-Rex Automates Testing by Measuring Phase Relationships of Transformer Windings While Appliying Three Phase Voltage
Internal Data Storage of 200 Test Results USB Port for Simple Data Transfer Simple Circuit Type Designations Using Diagrams Provided with Software for Computer Controlled Testing On Board Printer for Immediate Results Documentation Ratio Measurement from 0.8 to 15,000 Turns
Simple Operation and Controls 60kV AC Output Voltage Single Piece Construction Test Cells for ATSM D877, ASTMD1816 and IEC 156 Testing High Voltage Automatically Ramps, Dicharges, and Records Voltage Upon Flashover
27
Accurate, Fast Measurements for SF6 or Transformer Nitrogen Blanket Applications Measures Temperature, Dewpoint, Absolute Humidity, and Relative Humidity Provided by Intellirent with Sampling Cell and Fitting Kit Measurement Ranges from -60 to 60C (-76 to 140F) and 40 to 200K ppm
Self Contained Kit with Pressure Source Pump, Timer, Gauge, Fittings, Tubes, and Tools Battery Operated Relief Valve for Relay and Test Set Protection
Lightweight (8 Lbs) and Portable 122 F to 1202 F, Accuracy to 1F 12 Minutes from Ambient to 1200 F Provided with 1/16, 1/8, 3/16, 1/4, 1/3, 1/2 and 1 Inserts
28
888.902.6111
www.intellirentco.com
Measures Excitation Voltage and Current, Turns Ratio, Winding Polarity on Single Phase and Multi-Phase CTs Excitation Voltages Up To 1200V, Current to 2A (at 200V) Operation from Front Panel or Through Computer Control CT Ratio and Excitation Knee Point Calculated and Charted Automatically Capable of Testing 0.8 Through 5000 to 1 CT Ratios Onboard Printer For Immediate Results Documentation EZCT-10 Model Increases Excitation Current to 10A (at 200V)
Measures Excitation Voltage and Current, Turns Ratio, Winding Polarity on Single and Multi-Tap CTs Excitation Voltages to 2000V AC, Current up to 10A (at 300V) Fully Automated, Connects to All CT Output Terminals Simultaneously No Lead Switching Required Plots Multiple Saturation Curves Operations From the Front Panel or Through Computer Control CT Ratio and Excitation Knee Point Calculated and Charted Automatically Five Voltage Test Settings 50, 300, 500 and 1200 and 2000V AC Measures DC Resistance in CT Windings Onboard Memory Stores 140 Test Records (Of 10 Saturation Curves) and 128 Test Plans Ratio Accuracies of 1% or Better Extended 35 Lead Lengths
Measures Excitation Voltage and Current, Turns Ratio, Winding Polarity and Phase Angle Tests on Single and Multi-Tap CTs Measures Insulation Resistance and Winding Resistance on CT secondary windings Measures CT Secondary Burden Excitation Voltages to 2000V AC, Current up to 10A (at 300V) Fully Automated, Connects to All CT Output Terminals Simultaneously No Lead Switching Required Plots Multiple Saturation Curves Operations From the Front Panel or Through Computer Control CT Ratio and Excitation Knee Point Calculated and Charted Automatically Five Voltage Test Settings 50, 300, 500 and 1200 and 2000V AC Measures DC Resistance in CT Windings Onboard Memory Stores 140 Test Records (Of 10 Saturation Curves) and 128 Test Plans Ratio Accuracies of 1% or Better Extended 35 Lead Lengths
29
Provided With Kelvin Probes (pictured) Automated Measurement Detection and Storage Modes Onboard Printer Automatic Polarity Reversal Battery Operated
Provided with Kelvin Probes (pictured) Battery Operated, Light Weight and Compact Design User Selectable Test Current and Resistance Ranges Internal Storage of Readings with Data Storage and Analysis Software Included
Provided with Kelvin Probes (pictured) Battery Operated, Light Weight and Compact Design User Selectable Test Current and Resistance Ranges Internal Storage of Readings with Data Storage and Analysis Software Included Includes Temperature Compensation and User Selectable Resistive or Inductive Materials Measurement
30
888.902.6111
www.intellirentco.com
Measures Resistance Using 10A to 100A Output (In 2A Steps) Simple Push Button Control from the front Panel Provided by Intellirent with 30 Cables Accuracy is +/- 1% of Reading
Selectable Output from 10A to 200A Onboard Printer Provided with Heavy Duty Alligator Clamps and 15 Cables High Precision Measurements from .01 to 20 with Resolution of 0.01 Internal Memory Records 2000 Test results
Test Currents From 10 to 600A Internal Storage of Test Data for Download or Printing on Site with Optional Printer Lightweight (33 Lbs.) Compact Design Provided with Heavy Duty Alligator Clamp or Optional C Clamps
31
Large LCD Displays Bargraph and Insulation Resistance Measurement Ranges Up To 30G Test Voltages from 50V to 1kV Measures Voltage and Frequency Pass/Fail Indication with Bright Red/Green LEDs Built In Battery Charger USB and RS-232 Ports For Results Download and Documentation Includes EuroLink PRO Software
Line or Battery Operated Test Voltages from 250V to 5kV in steps of 50V Automatic PI, DAR and DD Index Calculations Adjustable Measurement Timer From 1 Second to 30 Minutes Automatic Discharge of Capacitive Loads Digital and Bar Graph Display Measures Insulation to 5 T Internal Memory Stores 1000 Measurements Capacitance Measurements up to 50uF
Line or Battery Operated Test Voltages from 250V to 5kV in steps of 25V Automatic PI, DAR and DD Index Calculations Programmable Step Voltage and Withstand Voltage Functions to Assist in Diagnosing Faults Plots Real Time Resistance to Time Adjustable Measurement Timer From 1 Second to 30 Minutes Capacitance Measurements to 50uF Automatic Discharge of Capacitive Loads Digital and Bar Graph Display Measures Insulation to 5 T Internal Memory Stores 1000 Measurements
32
888.902.6111
www.intellirentco.com
Simple to Use with Intuitive Controls and Features Battery or Line Operated Vary Test Voltages in 10V Increments Between 50V and 1kV and in 25V Increments from 1kV to 5kV Performs PI, Step Voltage, Dielectric Discharge, Dielectric Absorption Ratio Automatically. Burn and Breakdown Functions Available in Insulation Resistance Mode Load Capacitance is Measured and Reported when Tests are Concluded Provided with Download Software S1-1052/2 Extends Voltage Output Range to 10kV
Line or Battery Operated Test Voltages from 500V to 10kV in 25V Steps Automatic Discharge of Capacitive Loads Digital and Bar Graph Display Measures Insulation to 10 T Capacitance Measurements to 50uF
Continuously Variable Test Voltage to 15kV Line Operated Available in 5kV or 15kV Models Suitable for DAR, PI and Step Voltage Testing
33
Programmable High Current Source Appropriate for Testing Molded-Case Circuit Breakers and Thermal Magnetic or Solid State Overload Motor Protection Relays Rugged and Robust Design For Field Applications Onboard Multifunction Timer Simple Operations and Controls Four Current Outputs (5A @ 120V, 25A @ 24V, 120A @ 6V and 250A @ 3V)
Current
Instantaneous Current to 600A or Continuous Current to 240A Memory Ammeter and Seconds/Cycles Timer Lightweight (33 Lbs) and Compact Provided with 5 Heavy Duty (No. 4) Test Leads
34
888.902.6111
www.intellirentco.com
Programmable High Current Source for Utility Substation Applications for Relay or Breaker Applications On Board Multifunction Timer Measures Internal and External Currents Simple Operations and Controls
Output at 120V 5.6V at 100A 5.3V at 200A 4.9V at 300A 4.6V at 400A 4.2V at 500A 3.9V at 600A
Instantaneous Current to 1000A or Continuous Current to 240A From 110V. Memory Ammeter and Seconds/Cycles Timer Approximately 70 Lbs Provided with 5 Heavy Duty (No. 2) Test Leads
Instantaneous Current to 2000A to Continuous Current to 500A from 110V. Memory Ammeter and Seconds/Cycles Timer Approximately 115 Lbs Provided with 5 Heavy Duty (No. 2) Test Leads
35
Intuitive and Rugged MAC-20 Digital Instrumentation with Memory Ammeter and Seconds/Cycles Timer 208/240 or 480V Input Optional Autotransformer for 480V Input Provided by Intellirent with 1/2 and 3/4 Universal Stabs, Input Cables and Custom Output Cabling to Meet Specific Customer Requirements Output Current and Overload Capabilities:
18V Series 2000A 2800A 4000A 6000A 8000A 10000A 14000A * 20000A *
Overload 1X 1.4 X 2X 3X 4X 5X 7X 10 X
Max On Time Continuous 15 Min 5 Min 1.5 Min 45 Sec 4 Sec 2 Sec 1 Sec
Max Off Time N/A 15 Min 15 Min 15 Min 15 Min 2 Min 2 Min 2 Min
Max Input Current at 480V 94A 140A 187A 281A 375A 468A 656A 937A
Electrical Test Instruments PI-2500 / 5000 25,000A or 50,000A High Current Test Set
Intuitive and Rugged MAC-20 Digital Controller with Memory Ammeter and Seconds/Cycles Timer 55.2kVA Continuous for Testing up to 4000A Circuit Breakers 480V Input Rugged Two Piece Design Supports 2500A or 4000A Circuit Breaker Testing Provided by Intellirent With 1/2 and 3/4 Universal Stabs, Input Cables and Custom Output Cabling To Meet Specific Customer Requirements Output Current and Overload Capabilities:
7.6V Parallel 15.2V Series 4000A 5600A 8000A 16000A 20000A 32000A 40000A 60000A 2000A 2800A 4000A 8000A 10000A 16000A 20000A 30000A
Max On Time Continuous 15 Min 5 Min 1 Min 6 Sec 1 Sec .5 Sec .03 Sec
Max Off Time N/A 15 Min 15 Min 15 Min 2 Min 1 Min 1 Min 1 Min
Max Input Current 96A 134A 192A 384A 480A 672A 960A 1440A
Electrical Test Instruments PI-2500 / 5000 25,000A or 50,000A High Current Test Set
36
888.902.6111
www.intellirentco.com
Convenient One-Man Portable Two Piece Design, Total Weight Approximately 125 Lbs Intuitive and Rugged MAC-20 Digital Controller with Memory Ammeter and Seconds/Cycles Timer 4.2kVA Continuous Rating for Testing Up To 800A Circuit Breakers 120V or 208-240V Input (Switch Selectable) Optional Autotransformer for 480V Input Provided by Intellirent With 1/2 and 3/4 Universal Stabs, Input Cables and Custom Output Cabling To Meet Specific Customer Requirements Output Current and Overload Capabilities
4.2V Series/ Parallel 800A 1120A 1600A 2400A 3200A 4000A 5600A 8000A 12800A
8.4V Series 400A 560A 800A 1200A 1600A 2000A 2800A 4000A 6400A
Overload 1X 1.4 X 2X 3X 4X 5X 7X 10 X 16 X
Max On Time Continuous 15 Min 5 Min 2.5 Min 75 Sec 4 Sec 2 Sec .6 Sec .1 Sec
Max Off Time N/A 15 Min 15 Min 20 Min 20 Min 2 Min 2 Min 1 Min 1 Min
240V Input
Max Input Current at 240V 18A 25A 36A 50A 72A 90A 126A 180A 300A
Max Input Current at 120V 36A 50A 72A 100A 144A 180A N/A N/A N/A
Convenient One-Man Portable Three Piece Design, Total Weight Approximately 270 Lbs Intuitive and Rugged MAC-20 Digital Controller with Memory Ammeter and Seconds/Cycles Timer 240V Input Optional Autotransformer for 480V Input Provided by Intellirent with 1/2 and 3/4 Universal Stabs, Input Cables and Custom Output Cabling to Meet Specific Customer Requirements Output Current and Overload Capabilities:
4.2V Series/ Parallel 1600A 2250A 3200A 4800A 6400A 8000A 11200A 16000A
8.4V Series 800A 1125A 1600A 2400A 3200A 4000A 5600A 8000A
Overload 1X 1.4 X 2X 3X 4X 5X 7X 10 X
Max On Time Continuous 15 Min 5 Min 2.5 Min 75 Sec 4 Sec 2 Sec .6 Sec
Max Off Time N/A 15 Min 15 Min 20 Min 20 Min 2 Min 2 Min 1 Min
Max Input Current at 240V 38A 53A 75A 112A 150A 187A 262A 375A
37
Omicron CPC 100 Multifunction Primary Test System with Current Booster
Omicron CP CB2
Omicron CPC 100 and CP CB2 Multifunction Primary Test System with Current Booster Single Piece Design Suited for Automated Testing of Power Transformers, CTs, VTs, Resistance Testing and More Optimal For Emergent Requirements or Remote Applications - One Device Replaces Multiple Instruments CP CB2 Boosts Current Output to 2000A AC Output Current and Overload Capabilities:
38
888.902.6111
www.intellirentco.com
Instantaneous Current to 4500A or Continuous Current to 1200A Memory Ammeter and Seconds/Cycles Timer Two Man Portable; Controller Weighs 70 Lbs, Output Transformer Weighs 123 Lbs Input Voltage 208 and 240V, 30A Provided by Intellirent with Input Cables and Custom Output Cabling to Meet Specific Customer Requirements
Digital Controller Includes Memory Ammeter, Timer, and Voltmeter Intuitive DDA-1 Controller Provides for Simple Operation Provided by Intellirent with Universal 1/2 and 3/4 Stab, Input Cables and Custom Output Cabling to Meet Specific Customer Requirements Maximum Current Output At 480V Input: 4500A Maximum Continuous Current 35,000A Maximum Current Through a Circuit Breaker 60,000A Maximum Current Through a Short Circuit 30 Minutes On / 30 Minutes Off Duty Cycle Shipping Weight Approximately 1350 Lbs Available with Optional Megger AT-1 Input Autotransformer for 208/240 Source
Digital Controller Includes Memory Ammeter, Timer, and Voltmeter Intuitive DDA-1 Controller Provides for Simple Operation Provided by Intellirent with Universal 1/2 and 3/4 Stab, Input Cables and Custom Output Cabling to Meet Specific Customer Requirements Maximum Current at 480V Input: 6250A Maximum Continuous Current 60,000A Maximum Current Through a Circuit Breaker 100,000A Maximum Current Through a Short Circuit 30 Minutes On / 30 Minutes Off Duty Cycle Shipping Weight Approximately 1350 Lbs Available with Optional Megger AT-1 Input Autotransformer for 208/240 Source
39
Model
504 505 606 607 BTSB PR010/T TT1 METK1 1232C50G05 140D481G02 140D481G03 7801C57 1232C50G10 SPBPTK 8779C02G03 8779C02G04 MTK1000 PRTBAPMDV 70C1056 GTUTK20 PST1-1 TAKTS1 TVRMS2 TVTS1 34547 ETC-PTS PTS-4 ELTPHB TS-31 WLTS SBAPM WL FF PTS-5 S33595 S33594 UTS-3 CBTMB CBTM4A CBTM3 CON1111 1-AC-PRO-TS SCBII
Page
41 41 41 41 42 41 41 44 42 43 42 43 42 43 42 42 43 43 43 44 44 44 44 44 45 46 46 47 46 47 47 47 46 45 45 45 45 45 46 47 47 47
Please Contact Intellirent for Applications Assistance. Circuit Breaker Manufacturer, Model, Options and Vintage Affect Secondary Injection Test Set Selection.
40
888.902.6111
www.intellirentco.com
ABB 504
Power Shield Trip Units (ITE)
ABB 505
Power Shield Trip Units
ABB 606
MPS Trip Units
ABB 607
MPSC Trip Units
ABB PRO10/T
EMax/SACE Trip Units
ABB TT1
EMax/SACE PR Trip Units
41
ABB BTSB
MPS, MPSC and MPSC 2000 Trip Units
42
888.902.6111
www.intellirentco.com
43
GE TVTS1
MicroVersaTrip Trip Units
GE PST1-1
Power Sensor Trip Units
GE TVRMS2
MicroVersa Trip, MVT+, MVT PM Trip Units
GE TAKTS1
ECS / SST and VersaTrip Trip Units
GE GTUTK20
Entelliguard Trip Units
44
888.902.6111
www.intellirentco.com
Square D UTS-3
MicroLogic Trip Units
Square D S33594
MicroLogic, ET and STR Trip Units
Square D CBTMB
UTS-3 Adaptor for Series B Breakers
Square D S33595
MicroLogic, ET and STR Trip Units
Square D CBTM4A
UTS-3 Adaptor for Some Series 3 and 4 Breakers
45
Square D CBTM3
UTS-3 Adaptor for Some Series 1, 2, 3 and 4 Breakers
Siemens PTS-4
Static Trip, Static Trip II and Static Trip III Trip Units
Siemens PTS-5
Static Trip III Trip Units
Siemens WLTS
WL Circuit Breakers
Siemens TS-31
SB Circuit Breakers
46
888.902.6111
www.intellirentco.com
Siemens ELTPHB
VL Circuit Breakers
Siemens SBPAM
Power Supply for SB Circuit Breakers
Westinghouse SCBII
Seltronic and Series C Circuit Breakers
SureTrip CON1111
140D481G03 Adaptor for SureTrip/WestTrip Trip Units
47
Operates with Insertion Resistors up to 7000s Initiates Breaker Operation Trip/Close Coil Current Monitoring Capabilities Monitors all 3 Breaker Poles Simultaneously Available with Up to 12 Contacts On Board Printer for Immediate Results Documentation Computer Interface Allows for Data Collection and Operational Control Internal Data Storage of 200 Test Results USB Port for Simple Data Transfer Three Transducer Inputs Provided by Intellirent with Application Appropriate Transducer(s)
Operates with Insertion Resistors up to 7000s Initiates Breaker Operation Trip/Close Coil Current Monitoring Capabilities Monitors all 3 Breaker Poles at Once On Board Printer for Immediate Results Documentation Computer Interface Allows for Data Collection and Operational Control On Board Data Storage up to 150 Test Records Simplified Connections with One Main Contact Assemblys Single Transducer Input Provided by Intellirent with Application Appropriate Transducer
Vanguard Transducers
Please Contact Intellirent for Applications Assistance. Breaker Manufacturer, Model, Voltage, Options and Vintage Affect Transducer Selection All Transducers Connect Directly to Either the CT-6500 or the DIGITIMR Simple Setup Using Control Panel or Computer Integration with Breaker Analyzer
Description 10 Linear 24 Linear Universal Rotary With Magnetic Base Universal Rotary With Mounting Plate Circuit Breaker Model Specific Circuit Breaker Model Specific Circuit Breaker Model Specific
Vanguard Transducers
48
888.902.6111
www.intellirentco.com
Simple Operation and Logical Controls Indicates SF6 Volume Percentage (SF6 Purity by Volume) Independent of Atmospheric Pressure and Location Accuracy of +/- 1% by Volume for 0-100% SF6 in SF6/N2 Provided With DN20/DN8 Self Sealing Couplings and DILO Coupling DN20
Suitable to Connect 3-027-R002 To Most Gas Filled Apparatus SF6 Regulator Assembly DN8 Self Sealing Male to 3/8 Male NPT 1/4 FJIC 3/8 FJIC Siemens Aeroquip / SPS DN20 Self Sealing Male to 1 1/4 Parker (ITE, Westinghouse, ABB PA) DN20 Self Sealing Male to 3/8 Female NPT DN20 Self Sealing Male to 1 Male NPT DN20 Self Sealing Male to Malmquist (ABB PM)
LED Display of SF6 Intensity or Concentration Multiple Levels of Sensitivity with Real Time Adjustment Battery Operated, Lightweight, and Simple to Operate
49
Accurate, Fast Measurements for SF6 or Transformer Nitrogen Blanket Applications Measures Temperature, Dewpoint, Absolute Humidity, and Relative Humidity Provided by Intellirent with Sampling Cell and Fitting Kit Measurement Ranges from -60 to 60C (-76 to 140F) and 40 to 200K ppm
Rugged Field Portable Design Simple and Intuitive Front Panel Controls Metered Outputs 0-140V AC at 12A (2kVA) 0-240V AC at 2A (500VA) 0-480V AC at 1A (500VA) 0-190V DC at 12A 0-320V DC at 2A
Current Capability of 10A Continuous in Either AC or DC Voltage Ranges Variable DC Output Voltage of 300VDC Max Variable AC Output Voltage of 240VAC Max 110V Line Powered
50
888.902.6111
www.intellirentco.com
Rugged Construction for Field Use with Laboratory Accuracy and Precision Industry Standard for Testing Electrical Apparatus such as Transformers, Generators, and Cables Evaluates Integrity of High Voltage Substation Apparatus by Measuring Power Factor/Tan Delta Measures Capacitance to Evaluate Physical Changes Measures Accurately in High Electrostatic and Electromagnetic Conditions Line Frequency Modulation Technology Eliminates Substation Interference Provided by Intellirent with an M4000 Clipboard and DTAF Pre-Configured Laptop, Safety Strobe, Temperature / Humidity Transmitter Internal Field Calibration Reference Ensures Accurate Testing Built in Diagnostics Provide Information on Instrument Status Output Current to 300mA at 10kV (Total Output Power 3kVA) for Better Replication of In-Service Conditions Optional Type C Resonator Increases Output Capacity
Megger CB-100 Low Voltage Capacitance and Insulation Power Factor Test Set
Lightweight (21 lbs) and Portable Output of 26V at 100Hz Minimizes 60Hz Interference Performs UST and GST Configuration Testing Direct Reading of Capacitance and Dissipation Factor Simple Manual Interface Optimal for Transformer Dry Out
Megger CB-100 Low Voltage Capacitance and Insulation Power Factor Test Set
ABB CB-10 Portable Capacitance Bridge
Measures Capacitances without Making Any Disconnections Within Capacitor Bank Optimal For Substation Power Factor Correction Capacitor Banks Complete Kit With Clamp On CT
51
Quickly Identify Presence and Severity of Partial Discharge in Electrical Apparatus Baselines Partial Discharge Activity to Direct Maintenance Activities Measures Surface Partial Discharge As Numerical dB Values and Measures Internal Partial Discharge as Transient Earth Voltage (TEV) Values Gathers Partial Discharge Data For Comparison and Trending Automatically Grades Condition of TEV and Ultrasonic Values For Immediate Analysis Simple and Intuitive Operation through Menu Driven, Multifunction Display Provided by Intellirent With UltraDish Parabolic Waveform Concentrator, Flexible Sensor, External Microphone, Surface Contact Probe, and Headphones for Surface, Internal or Overhead Applications
Rugged and Compact Simple and Intuitive Front Panel Controls Broad Range of Applications Contact or Voltage Trigger
52
888.902.6111
www.intellirentco.com
0-100mA Output Current; 3kVA (Capacitive Load) Analog Meters Display Current Leakage and Voltage Output 20 Shielded Output Cable with Alligator Clamp Approximately 75Lbs. Optimal for Low Capacitance Substation Apparatus such as Vacuum Bottles, Breakers, Swtichgear, Bushings, Reclosers, Small Transformers and Motors
0-60mA Output Current; 3kVA (Capacitive Load) Analog Meters Display Current Leakage and Voltage Output 20 Shielded Output Cable with Alligator Clamp Approximately 85Lbs. Optimal for Low Capacitance Substation Apparatus such as Vacuum Bottles, Breakers, Swtichgear, Bushings, Reclosers, Small Transformers and Motors High Voltage PFT-1003CM Model Extends Voltage Range to 100kV (Includes Separate High Voltage Tank)
Automated Testing From 10kV to 60kV DC in 5kV Steps Selectable Dwell Time from 5 Seconds to 2 Minutes Digital Voltage and Current Display Failure Indicator LED Lightweight (10 Lbs) Display Indicates Test Voltage and mA Leakage During Test Selectable Overcurrent Limits of 100, 200 and 300mA
53
75kV Output Voltage at 10mA Continuously Adjustable Output Voltage Convenient and Compact Single Piece Design Dual Range Voltage Meter Scaled 0-37.5/75 kVDC Microamp and Megohm Meter Scales for both Leakage Current and Resistance Measurements 20 Shielded Output Cable with Alligator Clip Switchable Guard/Ground Load Return Path
80kV Output Voltage at 10mA Continuously Adjustable Output Voltage Convenient and Compact Single Piece Design Dual Range Voltage Meter Scaled 0-40/80 kVDC Microamp and Megohm Meter Scales for both Leakage Current and Resistance Measurements 20 Shielded Output Cable with Alligator Clip Switchable Guard/Ground Load Return Path
130kV Output Voltage at 10mA Continuously Adjustable Output Voltage Functional Two Piece Design High Voltage Tank is Approximately 82 Lbs, Controller is Approximately 35 Lbs. Dual Range Voltage Meter Scaled 0-70/130 Microamp and Megohm Meter Scales for both Leakage Current and Resistance Measurements 20 Ft. EPR Output Cable Stays Flexible During Cold Weather Use Switchable Guard/Ground Load Return Path
54
888.902.6111
www.intellirentco.com
200kV Output Voltage at 5mA Continuously Adjustable Output Voltage Functional Two Piece Design High Voltage Tank is Approximately 150 Lbs, Controller is Approximately 35 Lbs Dual Range Voltage Meter Scaled 0-80/200 Microamp and Megohm Meter Scales for both Leakage Current and Resistance Measurements 20 Ft. EPR Output Cable Stays Flexible During Cold Weather Use Switchable Guard/Ground Load Return Path
Output Voltage is 60kV Peak at 5.5mA Max Adjustable Output Frequency of 0.1, 0.05, or 0.02 Hz (Sinusoidal) Capable of Testing 35kV Cable up to a Maximum Distance of 10 Miles Metering Includes Voltmeter 0-60kVAC Peak, Charging Current Meter 0-100mA Peak, and Load Capacitance Meter 0-6Farads 20 Shielded Output Cable Two Piece Design; Controller Is Approximately 75 lbs and the High Voltage Tank Is Approximately 120lbs
High VA Output Suitable For Applications Not Met by Smaller More Portable Systems Capacity Optimal For Testing ISO-Phase Bus and Other Capacitive Loads Two Piece Design; Controller Approximately 50 Lbs and Tank Approximately 190 Lbs 240V Input Duty Cycle of 5 Minutes On / 15 Minutes off at 7.5kVA (Full Output), 15 Minutes On / 1 Hour Off at 5kVA and 1 Hour On / 1 Hour Off at 3kVA Output Capacity of 50kV at 7.5kVA for 150mA Output Capacity of 100kV at 7.5kVA for 75mA Bolt Type Output Terminals For Simple Connection To Test Apparatus
55
Lightweight (44 lbs) and Compact Single Piece Construction for Enhanced Portability and Logistics Simple and Intuitive Menu Driven User Interface Appropriate for Cables, Capacitors, Switchgear, Transformers, Rotating Equipment, Insulators and Bushings 33kV (Peak) VLF at 0.1 Hz, 0.05 Hz or 0.02 Hz or DC Output Digital Metering Displays Voltage and Current (RMS or Peak), Capacitance, Resistance, Duration and Flashover Voltage Manual or Automated Testing Sequences Based on Applicable Standards True Symmetrical Sinusoidal, Load Independent Output Waveforms Across Full Load Range Short Circuit Protection with Active Arc Management Provides for VLF and DC Testing, Jacket/Sheath Testing and Fault Conditioning Internal Storage or Test Results Seamless Integration with HV Diagnostics TD30 Tan Delta System
Compact and Battery Operated Solid State, Air Insulated Design Configuration and Data Extraction Through Bluetooth Connection Provided with Powerful and Intuitive Tan Delta Analysis Software with Tan Delta Curve Display Real Time Display of Actual Waveform Output and Data Seamless Integration with HV Diagnostics HVA30 System Visual Indication of TD Levels
56
888.902.6111
www.intellirentco.com
Single Piece Construction for Simplified Logistics Portable at 135 Lbs Simple and Intuitive Menu Driven User Interface 62kV (Peak) VLF at 0.1 Hz, 0.05 Hz or 0.02 Hz or DC Output Capable of Testing 1F at 0.1 Hz, 62kV Peak Voltage (Approximately 10,000 Feet of Cable) with Alligator Clip Appropriate for Cables, Capacitors, Switchgear, Transformers, Rotating Equipment, Insulators and Bushings Digital Metering Displays Voltage and Current (RMS or Peak), Capacitance, Resistance, Duration and Flashover Voltage True Symmetrical Sinusoidal, Load Independent Output Waveforms Across Full Load Range Short Circuit Protection with Active Arc Management Provides for VLF and DC Testing, Jacket/Sheath Testing and Fault Conditioning Manual or Automated Testing Sequences Based on Applicable Standards Internal Storage or Test Results Seamless Integration with HV Diagnostics TD60 Tan Delta System
Compact and Battery Operated Solid State, Air Insulated Design Configuration and Data Extraction Through Bluetooth Connection Provided with Powerful and Intuitive Tan Delta Analysis Software with Tan Delta Curve Display Real Time Display of Actual Waveform Output and Data Seamless Integration with HV Diagnostics HVA60 System Visual Indication of TD Levels
57
Integrated VLF and Tan Delta Measurement In Single Unit Suitable For Testing Medium Voltage Cables to 15kV (20kV For Tan Delta Diagnostics) Cable Testing According to IEEE 400-2001, IEEE P 400.2-2001, and VDE DIN 0276-620/621 (CENELEC HD 620/621) Cable Sheath Testing According To IEEE 433, IEC 60502 and VDE 0276-620 Fully Automated Testing and Diagnostic Sequences Simple Menu Driven Setup for Manual Testing Quick and Easy Measurement Structure Baur PD Portable Adds Complete Diagnostic System Precision Measurement with Accuracy of 1 x 10-4 Load Range of 10nF to 8uF Sinusoidal or Rectangle Wave Shape Automatic Load Discharge Onboard Results Storage and Management of Data with Included Software Provided by Intellirent With a Preconfigured Laptop Computer Includes Ground and Discharge Rod Lightweight (42 Lbs) and Compact for Simplified Transportation
58
888.902.6111
www.intellirentco.com
Whether you need equipment put on the next flight to an outage, or need it delivered on the other side of the world, our equipment travels first class.
Set up right, ready to go to work Custom cases and packaging for a secure trip
Return shipment packging and labels, for the return trip All to ensure you can do your job out of the box ready to go
Shipment tracking and controls in case we get lost For longer trips, international transportation documents for a quick transition.
59
Rugged Construction for Field Use With Laboratory Accuracy and Precision Evaluates Integrity of High Voltage Apparatus Measures Capacitance to Evaluate Physical Changes Measures Accurately in High Electrostatic and Electromagnetic Conditions Provided by Intellirent With DTAF and M4000 Preconfigured Laptop Computer Output Current to 300mA at 10kV for Better Replication of In-Service Conditions
Increases Output Capacity of Doble M4000 for Cable and Other Capacitive Apparatus No Software or Additional Hardware Required Available For Rental Individually or With Doble M4000
60
888.902.6111
www.intellirentco.com
Fluke FOM / FOS Fiber Optic Power Meter and Light Source
Economical Solution to Measuring DB Loss on Fiber Optic Cables Simple Setup and Operation; Plugs Into DMM Available with ST to ST, ST to FC, ST to SC, ST to SMA Adaptor Cables Available in 850, 1300 or 850/130 Light Sources
Fluke FOM / FOS Fiber Optic Power Meter and Light Source
AEMC 2620 AC Leakage Current Probe
Locates Faults on High Current Loads High Sensitivity Enables Readings from 500 A to 400A Using Two Ranges Capable of Measuring Leakage Current on Single or Three Phase systems Jaw Opening of 4.5 5 Output Leads
Appropriate for Any Cable with At Least Two Insulated Metallic Elements (Including Sheath or Shield) Large Graphic Display Permits Comparison of Test Data for Simple Fault Location Dual Input and Output Ports for Simultaneous Two Phase Measurement Internal Storage of 15 Tests Simple Download of Test Data with Included Software
61
Large LCD Displays Bargraph and Insulation Resistance Measurement Ranges Up To 30G Test Voltages from 50V to 1kV Measures Voltage and Frequency Pass/Fail Indication with Bright Red/Green LEDs Built In Battery Charger USB and RS-232 Ports For Results Download and Documentation Includes EuroLink PRO Software
Line or Battery Operated Automatic PI, DAR and DD Index Calculations Adjustable Measurement Timer from 1 Second to 30 Minutes Automatic Discharge of Capacitive Loads Digital and Bar Graph Display Measures Insulation to 5 T Internal Memory Stores 1000 Measurements
Line or Battery Operated Automatic PI, DAR and DD Index Calculations Programmable Step Voltage and Withstand Voltage Functions to Assist in Diagnosing Faults Plots Real Time Resistance to Time Adjustable Measurement Timer From 1 Second to 30 Minutes Automatic Discharge of Capacitive Loads Internal Memory Stores 1000 Measurements
62
888.902.6111
www.intellirentco.com
Line or Battery Operated Test Voltages of 500V, 1000V, 2500V and 5000V Insulation Measurement to 10T Direct Measurement and Display of Resistance, Test Voltage, Test Duration, Capacitance and Leakage Current Large Backlit Display Field Portable and Rugged Automatic Calculation of DAR, PI and DD AEMC 5060 Model Adds Results Storage and Download Capability
Line or Battery Operated Test Voltages from 500V to 10kV in 25V Steps Automatic Discharge of Capacitive Loads Digital and Bar Graph Display Measures resistance to 10 T ohms
Continuously Variable Test Voltage to 15kV Line Operated Available in 5kV or 15kV Models Suitable for PI, DAR and Step Voltage Testing
63
Single Piece High Voltage Thumper, ARC Reflection TDR, DC Hipot and Low Voltage TDR Rugged and Reliable Compact Design (50 Lbs) Simplified Transportation Through Common Express Carriers One Man Portable Battery or Line Powered Optimal For Shielded High Voltage Cables Quickly Indicates Fault Type and Actual Distance to Fault in Feet Simple To Operate and Indentify Fault Location For Less Familiar Users Sophisticated Circuitry Ignores Transformer Reflection and Locks on Fault Location Locates Faults To 10,000 Ft. (Maximum Capacitance of 7uF) Variable Impulse Voltage (Thump) For Minimal Cable Damage Variable Velocity of Propagation For Precision Adjustment to Specific Application 350 Joule Pulse Can Often Be Heard Above Ground Included Fault Wizard Software Enables Viewing and Recording Of Trace
64
888.902.6111
www.intellirentco.com
Two Channel System Enables Directional Fault Identification Bright Backlit Display Indicates Distance To Fault and Fault depth Optional Stirrup Probes for Hard Surfaces Fault Centering Function Quickly Orients User To Fault Location Simple Operation For Less Familiar Users Provided by Intellirent as a Complete Kit
Locates Underground Energized and Deenergized Wires, Cables and Pipes Power, Radio and Induced Signal Operation Modes Provided by Intellirent with the Amprobe GS-3000 Transmitter for Signal Induction by Swamp, Direct Connection or by Signal Clamp Method Depth Measurement to 10
Traces energized and Deenergized Cables and Circuits in Walls or Switchgear Locates Circuit Breakers Neutral and Ground Cables Pinpoints Shorts, Ground Faults and Broken Cables Provided by Intellirent as a Complete Kit, Including Receiver, Transmitter, Transmitter for Open Tracing, Clamp On, Battery Booster, Battery Charger and Lead Sets
65
Identifies and Locates Ground Faults in Ungrounded DC Systems Operates in Energized Systems Digital Display of Voltage and Current Amplitudes Optional Bridge Measurement of Fault Resistance (from 1 k to 399 k) Soft-Start Charging System Prevents Sensitive Relay Tripping Simplifies Fault Tracing by Identification of Fault Characteristics Includes Line Operated Transmitter and Battery Operated Receiver for Remote Tracing
Measures Specific Gravity of Electrolyte Internal Pump Draws Electrolyte into Sample Chamber Simple One-Button Test Automatic Temperature Compensation
Designed to Operate on 125V DC Systems Variable 0-250A DC On Board Fans and Temperature Controls Analog Current Meters Provided With The Users Choice of Test Cables Powered by Battery Under Test Lightweight (50 Lbs) and Portable
66
888.902.6111
www.intellirentco.com
Compact and Portable System Designed to Meet IEEE Standards for Battery Testing Measurement and Results Not Affected by Ripple (AC Noise), Natural Battery Capacitance or the Magnitude of Test Current Large, Backlit LCD Battery or Line Powered Measures and Records Cell Voltage, Internal Battery Resistance and Intercell Resistance Internal Resistance Measurements Detect Failing Cells Before Failure Bluetooth Capable Onboard USB Flash Drive For Simple Transition of Data to PC Included Battery Analysis Software Identifies Problematic Cells, Creates Reports and Archives Data irDA Communications Available for Communications With PC or Optional Alber Hydrometer Test Battery Cells From 0-16V Includes Battery Test Clamps and Multiple Jaw Options Provided by Intellirent With Interchangeable Spike Probes
Provided by Intellirent as a Complete System with A Fluke DAQ Pre-Configured Laptop Computer, Appropriate Input Modules and Networking Configuration Components Prewired with Input Signal Leads as Required Measure up to 120 Signals Per Unit or 720 Signals by Combining 2686 Units Sampling Rate Adjustable from 1000 Readings/Second to 1 Reading/Hour Measure AC or DC Voltage, Resistance, Frequency, RTD and Thermocouples, Thermistor and Current (including 4..20 loops) Simple Configuration and Setup
67
Three Wire 62% Fall of Potential Testing Four Wire Soil Resistivity Measurement Two Wire Point to Point Testing Clamp on Testing with Optional Current Probes Adjustable Output Voltage Internal Memory Stores 1000 Test Results Provided by Intellirent with Complete Ground Test Kit
Compact and Robust Design Three Wire 62% Fall of Potential Testing Four Wire Soil Resistivity Measurement Two Wire Point to Point Testing Selective (Contactless) Resistance Testing With Two Clamps Attached Rod Technique Testing Simple Clamp on Ground Testing USB Communications and Onboard Results Storage Provided by Intellirent With a Comprehensive Accessory Kit
Three Wire 62% Fall of Potential Testing Four Wire Soil Resistivity Measurement Two Wire Point to Point Testing Rejects High Levels of Noise and Interference Push to Test Simplicity Provided by Intellirent With a Comprehensive Accessory Kit
68
888.902.6111
www.intellirentco.com
Measure Ground Rod and Grid Resistance without Driving Temporary Ground Rods Verifies Quality of Grounding Connections/Bonds and Continuity of Ground Loops Measures Ground Current Jaw Opening of 1.25 AEMC 3731 Includes a Display Hold Function
Simple One Button Operation Selectable Test Voltages (25 or 50V) 0.01 to 2000 Range Provided Complete with Leads and Temporary Ground Rods Automatic Noise Check and Rejection to 40V Peak-to-Peak Use In Conjunction with Megger IClamp for Attached Rod Technique Testing Measure Leakage Current From 0.5 to 19.9A Use in Conjunction with Megger DET3TC For Complete Attached Rod Technique Testing Enables Testing of On-Site Grounds Separately without Removing Utility Connection
Versatile for All Types of Earth Resistance Measurements Resistivity Through Wenner and Schlumberger Methods Ground Coupling Ground Potential Measurement Continuity and Resistance Analyzes Frequency Behavior of Grounding Systems Rejection of Interference Voltages to 60V Automatic Calculation of Ground Coupling Coefficient and Ground Resistivity Measurement and Analysis of Tow Leg Grounding Full Results Recording Provided As Complete Kit for 3 Point, 4P or 4P Selective Method, Earth Measurement With 2 Clamps, Resistivity, Earth Potential Measurement, DC Resistance Measurement and Tower Ground Measurement
69
Versatile Single Phase Standard with typical accuracy of 0.005% Throughout Operating Range Integrated Analog to Digital Signal Converter For Real World Waveform Measurement Four Quadrant Measurement Registers Forward and Reverse Energy Flow and Documents Voltage, Current, Power and Energy (Active, Reactive, and Apparent) Optional Harmonic Analysis Through 50th Harmonic Order Built In Comparator Provides Automatic Calculation of Test Results BNC for Input/Gating, Pulse Outputs and Phase Synch or Analog Sense Intuitive Five Button User Interface for Setup of Measurement, Test Sequence, and Harmonics Seamless Integration With Radian Accessories
Type RM-1Hz RRKYZ-2 RR-1H RR-DS (Suction Mount) RM-111 RR-DS (Field Mount) RM-KYZ RR-1HV RR-KYZ RM-1S
Description LED Pickup KYZ Adaptor (Form A and C Compatible) Optical Pickup for LED Meter Disk Sensor with Suction Cup Mount Comparator Meter Disk Sensor Pulse Inputer Infrared Pickup Pulse Input Adaptor Remote Reset Switch
70
888.902.6111
www.intellirentco.com
Complete Automated Test Bench with Internal Multifunction Standard Typical Accuracy of +/- 0.025% Analog Input for Testing Watt, VAR, Current and Voltage Transducers Menu Driven Routines for Series and Per Phase Full Load, Light Load and Power Factor Testing Built In Precision Current and Voltage Sources Provide Accurate and Repeatable Test Results, Especially on Loss Compensated Meters Infrared LED Sensor, Disk Sensor and KYZ Relay Pulse Test Pickups Included Simplified for Field Applications, PC Controlled with Automated Menu Driven Test Routines Active Test Methodology with Integrated Pure Sinusoidal Current and Voltage Sources Test Ranges from 10mA to 30A and 0V to 600V Provided With Transdata 2130 Software
Measure Current to 400A and Voltage to 1kV at 40 MHz High Resolution Monochrome Display Sample Rate of 25 MS/s Divisions of 5mV 500V Scope Record Mode will Record 512 min/max Points Per Input Internal Memory of up to 20 Screens and Setups Provided by Intellirent with FlukeView Scopemeter Software
Lightweight (Approx 5 Lbs) and Portable Frequency Range of .5Hz to 5Mhz Sine, Triangle, Square, Ramp TTL and CMOS Output External Voltage Controlled Frequency Variable DC Offset Control Integrated 6 Digit Counter and INT/EXT Functions up to 150MHz High Resolution LIN/LOG Sweep Mode INT/EXT AM/FM Modulation
71
Original Synchroscope Large Analog Meter Displays Phase Angle Differential Or Actual Phase Angle To Reference 0-360 Degree Indication of Phase Angle and Power Factor Indication of Leading or Lagging Power Factor Two Inputs at 15-480V or 1-30A
Light Weight (13 Lbs) and Simple to Use with Intuitive Controls Battery or Line Operated Measure Voltage, Current (100A Directly or Higher With Optional CTs), Phase Angle, Power, Reactive Power, Frequency, Harmonics, and Time (Seconds or Cycles) Onboard Datalogger Records Events Displays Three Phase Voltage, Current, Phase Angle, Power, Reactive Power, Power Factor, and Frequency Simultaneously. Variable PT and CT Ratios for Display of Primary Values
Ten Simultaneous Measurements of Frequency, Phase Angle, AC/DC Voltage, AC Current (200A Max), Power Factor, Watts, and VARS. On Board Timer Measures Cycles or Seconds Based on State or Contact Changes Lightweight and Simple to Operate Phasor Display of AC Values Battery or Line Powered
72
888.902.6111
www.intellirentco.com
Provided With Three Open Sensor CTs Suitable For Use On 69kV Systems Sensor Opening of 1.3 +/-1% Accuracy to 1000A Provided With Softlink Software and IrDA Communications Cable
Open Horseshoe Design Slips On and Off Conductor easily Simple One Button Operation Suitable For Use On Systems to 150kV Rejection of Stray Magnetic Fields 0-2000A at +/- 1.5% Accuracy Fiber Optic Isolation of Signal To Coupling Device Analog Output For Waveform Analysis Spline Type Hotstick Connection
Measures Up To 40kV AC Simple One Button Operation Rejection of Stray Magnetic Fields Fiber Optic Isolation of Signal To Coupling Device Analog Output For Waveform Analysis Spline Type Hotstick Connection
73
Small and Lightweight (less than 1 Lb) Capable of Operation from 100 to 600V with a Frequency Range from 45 to 65 Hz Powered by Apparatus Under Test
Tests Electrical Equipment and Medical Instruments To AAMI, UL and NFPA Codes Measures Leakage Current, Voltage and Resistance Insulation Tests to 100V Open Ground and Neutral Test Switches Line, Voltage, Polarity and Receptacle Ground Test Polarity Switch for Test Receptacle Includes Isolated Power System Tests and Line Isolation Test
Simple and Intuitive Operation Determines Integrity of Isolated Systems and Grounding LIM and GFCI Testing Large LCD Display Operates on System Voltages up to 240V System Leakage Measurement
74
888.902.6111
www.intellirentco.com
Designed Specifically for Line Trap Work Operates at 30kHz to 500kHz Direct Display of Impedance Magnitude for Quick and Simple Resonant Frequency Determination Large Ruggedized Analog Meter Dual Range: .1-4k and 1.0-40k Field Portable and Battery Operated Lightweight (5 Lbs) Design
Designed Specific for Line Trap Work - Perform PLC Transmitter Emulations, Line Tuner and Line Trap Tune Ups, System Line Ups and Receive Level Checks Operates from 100 Hz to 500kHz for Audio Tones Up Through PLC Frequencies Two Watt Output (50 Load) From Battery Power Nine Sweep Rates and 10 User Programmable Memory Registers
Measures Voltage At Frequencies of 50 Hz to 5 Mhz Includes Signal Generator Onboard Storage and Recall Functions Permit Quick Configuration Selectable Bandwidths of 50Hz 5Mhz, 3100Hz, 1950Hz, 100Hz and 25Hz Automatic Frequency Control Adjusts The Receiver to Center on the Actual Input Frequency Max Hold Displays The Maximum Signal Level Adjustable Bridge Impedance from 1 to 999 AM, SSB (USB, LSB) and DSB Demodulator
75
Measures Capacitors from 1F to 199,200 F in 10 Ranges Measures Capacitor Leakage from 1mA to 9.99kmA Measures Inductance from 10 mA/mSec 1 mH to .1mA/mSec 9,990 mH Accuracy of 2%
Quick, Basic LCR Measurements Hand Held with Simplified Controls Measures Resistance from .001 to 9.999M Measures Capacitance from .01pF to 19.99mF Measures Inductance from 0.01uH to 999.9H Onboard Data Storage and Download Through Included Software and IR/ USB Communications Cable
Measure AC and DC Voltage, AC and DC Current, Resistance, Capacitance, Frequency, Temperature and Conductance Industry Standard with Simple, Intuitive Operation Available With A Wide Variety of Input Modules for Pressure, Current to 2000A, Voltage to 40kV, Fiber Optic Measurement, Temperature, and more Available in Intrinsically Safe Version Fluke 187 Model Provides Datalogger Functionality with Software Fluke 789 Model Adds Capability to Source and Measure 4.20mA with 0.05% Accuracy
76
888.902.6111
www.intellirentco.com
Large Auto Ranging LCD Reads to 50kV Dual Stick Design Optimal for Phasing 15 Coiled Connection Lead Available with 3 or 6 Hot Sticks
Direct Connection to 15kV Systems Three Probes Included With Kit Threaded Extendable Hotsticks Included Hook Tip and Long Leads Maximize Convenience for Connections
Instant Phase Rotation Indication on Systems Up to 5kV LED Indication of Phase Rotation Open Phase Detection
77
Inspection Equipment
Merge Infrared and Real Light Images (Taken Through the Same Lens) for Image Location Identification and Effective Reporting Through Fusion Technology 5 High Resolution Display Visible in Daylight Laser and Visible Light Output 160 x 120 Focal Plane Array, Uncooled Microbolometer Three Times Digital Zoom Provided by Intellirent with Powerful and Compressive Fluke SmartView Software which Permits User to Select Picture in Picture, Merged Thermal and Visual Light Images, Full Thermal or Full Visual Images.
Merge Infrared and Real Light Images (Taken Through the Same Lens) for Image Location Identification and Effective Reporting Through Fusion Technology 5 High Resolution Display Visible in Daylight Laser and Visible Light Output 320 x 240 Focal Plane Array, Uncooled Microbolometer Sensitive to 0.05 C 2x, 4x and 8x Digial Zoom Provided by Intellirent with Powerful and Compressive Fluke SmartView Software which Permits User to Select Picture in Picture, Merged Thermal and Visual Light Images, Full Thermal or Full Visual Images.
78
888.902.6111
www.intellirentco.com
Field Rugged and Optimized For Use In Harsh Environments Tested To Withstand a 6 Drop Convenient Pistol Grip Design Crisp, Clear Images With a 320 x 240 Sensor Flukes NETD Thermal Sensitivity Identifies Minute Differences In Temperatures Merge Infrared and Real Light Images for Image Location Identification and Effective Reporting Through IR Fusion Technology Optional Wide Angle and Telephoto Lenses Field Replaceable Batteries for Maximum Flexibility Intuitive Three Button Menu Voice Recording Emissivity Correction, Single Hand Focus Capability, and Temperature Compensation Provided by Intellirent with Powerful and Comprehensive Fluke SmartView Software
Appropriate for Leak Detection or Corona Detection Easy to Use Visual and Audible Indication of Amplitude 8 Position Sensitivity Selection Provided by Intellirent with Two Focusing Probes, Microphone Sensor and Contact Sensor with Extensions
79
Inspection Equipment
Quickly Identify Presence and Severity of Partial Discharge in Electrical Apparatus Baselines Partial Discharge Activity to Direct Maintenance Activities Measures Surface Partial Discharge As Numerical dB Values and Measures Internal Partial Discharge as Transient Earth Voltage (TEV) Values Gathers Partial Discharge Data For Comparison and Trending Automatically Grades Condition of TEV and Ultrasonic Values For Immediate Analysis Simple and Intuitive Operation Through Menu Driven, Multifunction Display Provided by Intellirent With UltraDish Parabolic Waveform Concentrator, Flexible Sensor, External Microphone, Surface Contact Probe, and Headphones for Surface, Internal or Overhead Applications
80
888.902.6111
www.intellirentco.com
Available with 6 Ft or 16 Ft Probe User Adjustable Viewing Angle User Configured Field of View from 34 to 56 degrees 0.4 to 2.4 In Depth of Field Wireless Console and Viewer Onboard SD Memory Card Integrated Microphone Records Users Voice Notes Still Image or Video Capture Battery Operated
Time Weighting Curves for Slow (550ms) and Fast (55ms) Frequency Weighting Curves Type A and Type C Programmable Integrating Time with Real Time Calendar Datalogger Records 32,000 Records at User Specified Interval
Peak Function Captures Light Pulse HOLD and MIN/MAX Functions Remote Sensor Measures Foot Candles to 40k or Lux to 400k
81
Inspection Equipment
Measure -25 to 1000 F with Distance to Spot Ratio of 12:1 Backlit Display Holds Minimum, Maximum and Average Readings Emissivity Fixed at .095 Accuracy better than 3 F Throughout most Ranges
Measures Electromagnetic Field Radiation Levels Displays EMF level in Milligauss or Microtesla Accuracy of 4% Over Operating Range of 0.1 to 199.9mG ELF Frequency Bandwidth of 30Hz to 300Hz
Low Maintenance, Easy to Use and Compact Optimal for Non-Contact and Contact Requirements Built in Photoelectric Pickup Operates to a Distance of 12 Inches Accuracy to 0.025% of Reading for Angular Readings and 0.2% for Linear Measurements
82
888.902.6111
www.intellirentco.com
Digital Display with Fine and Coarse Flash Rate Adjustment 30-14,000 Flashes Per Minute Internal Phase Shifting Times Two and Divide by Two for Immediate Check of Actual RPM versus Harmonics Store and Recall Six Memory Values Provided by Intellirent with Spare Bulbs, Case and Charger
Measures Vibration Velocity in Inches/Second with Accuracy of 2% Resolution of 0.01 Inches/Second Accelerometer Provided with Magnetic Mount or Probe SPM VIB-10 Model Displays mm/Second
Single Axis Meter for Acceleration, Velocity and Displacement Large LCD Displays Bargraph Style and Numeric Values Onboard Memory Records up to 1000 Data Points for Results Documentation with Included Software and Communications Cable 30 Hours of Continuous Use with Disposable Batteries
83
Portable and Battery Powered Monitors Power Circuit, Insulation, Stator, Rotor and Air Gap Variable Test Voltage from 250V to 5kV Automatic IR, PI, DAR and Step Voltage Tests Measures Insulation Resistance to 3T Precision Resistance Measurement From 10u to 2000 Using Four-Wire Bridge Measures Capacitance (pF) and Inductance (mH) Provided by Intellirent with MCEGold Preconfigured Laptop Computer
Rugged Construction for Field Use with Laboratory Accuracy and Precision Industry Standard for Testing Electrical Apparatus such as Transformers, Generators, and Cables Evaluates Integrity of High Voltage Substation Apparatus by Measuring Power Factor/Tan Delta Measures Capacitance to Evaluate Physical Changes Measures Accurately in High Electrostatic and Electromagnetic Conditions Line Frequency Modulation Technology Eliminates Substation Interference Automated Testing Procedures Through DTA or Manual Through M4000 Clipboard Provided by Intellirent with an M4000 Clipboard and DTAF Pre-Configured Laptop, Safety Strobe, Temperature / Humidity Transmitter Internal Field Calibration Reference Ensures Accurate Testing Built in Diagnostics Provide Information on Instrument Status Output Current to 300mA at 10kV (Total Output Power 3kVA) for Better Replication of In-Service Conditions Optional Type C Resonator Increases Output Capacity
Increases Output Capacity of Doble M4000 for Generators and Other Capacitive Apparatus No Software or Additional Hardware Required Available For Rental Individually or With Doble M4000
84
888.902.6111
www.intellirentco.com
Onboard Identification and Location of Common Mechanical Faults (Bearings, Misalignment, Unbalance and Looseness) Graded Fault Severity For Maintenance Prioritization Integrated 2GB Memory for Complete Machine Analysis Integrated Laser Tachometer Tri Axial Analysis of Acceleration, Displacement and Velocity Document and Trend Results With Included Software Suitable For Analysis of Rotating Equipment from 200 to 12,000 RPM Simple and Intuitive Setup, Measurement and Diagnosis
50A Outpu for testing large geenrators and motors with repeatable readings Automatically Demagnetizes Winding upon Test Completion 2 Measurement Channels and Onboard Printer Convenience Bright Touchscreen Interface or Full Computer Control Color Coded Connections and Simple interface for Fast Familiarization Automatic Discharge Circuit Optional Heat Run Software and Three RTD Inputs
Line or Battery Operated Test Voltages from 500V to 10kV in 25V Steps Automatic Discharge of Capacitive Loads Digital and Bar Graph Display Measures Insulation to 10 T
85
Three Operating Modes: Normal, Bar Hole and Leak Check Simultaneous Detection of LEL, O2, H2S and CO Internal Sample Pump Draws Air Through Included 40 Hose Alarms and Vibrates When Potential Danger Thresholds Are Reached Optimal for Confined Space Entry or Remote Monitoring RKI GX-2003 model adds internal sample pump
Simple and Intuitive Operation Determines Integrity of Isolated Systems and Grounding LIM and GFCI Testing Large LCD Display Operates on system voltages up to 240V System Leakage Measurement
Tests Electrical Equipment and Medical Instruments To AAMI, UL and NFPA Codes Measures Leakage Current, Voltage and Resistance Insulation Tests to 100V Open Ground and Neutral Test Switches Line, Voltage, Polarity and Receptacle Ground Test Polarity Switch for Test Receptacle Includes Isolated Power System Tests and Line Isolation Test
86
888.902.6111
www.intellirentco.com
Fully Automated Testing Through Front Panel or Computer Control 5kV AC Output with 20mA Sourcing 6kV DC Output with 7.5mA Sourcing Digital Current and Voltage Display Programmable Ramp and Dwell Time Arc Detection
Large Auto Ranging LCD Reads to 50kV Dual Stick Design Optimal for Phasing 15 Coiled Connection Lead Available with 3 or 6 Hot Sticks
Amprobe TIC300HV and H10A AC Voltage Detector with Extendable Hot Stick
30V to 121kV Tic Tracer Audible Alarm when Voltage is Present Available with Amprobe H10A Extendable 6 Hotstick
Amprobe TIC300HV and H10A AC Voltage Detector with Extendable Hot Stick
87
Simultaneous Input and Output Optional Pressure Modules Available in All PSIA, PSID, and PSIG Ranges Measures and Sources Thermocouple and RTDs Calibrates Loops, Voltage, mV, and Frequency Measures Resistance and Provides Loop Power Hart Functionality Optional DPC Track Software Manages Calibration Recordkeeping Data Internally Records and Documents Calibrations and Data
Simultaneous Input and Output Visible on Split Screen Measures and Sources Thermocouple and RTDs Calibrates Loops, Voltage, mV, and Frequency Measures Resistance and Provides Loop Power Optional Pressure Modules Available in all PSIA, PSID, and PSIG Ranges Fluke 725EX Model is Intrinsically Safe
Measure AC and DC Voltage, AC and DC Current, Resistance, Capacitance, Frequency, Temperature and Conductance Industry Standard with Simple, Intuitive Operation Available With A Wide Variety of Input Modules for Pressure, Current to 2000A, Voltage to 40kV, Fiber Optic Measurement, Temperature, and more Available in Intrinsically Safe Version Fluke 187 Model Provides Datalogger Functionality with Software Fluke 789 Model Adds Capability to Source and Measure 4.20mA with 0.05% Accuracy
88
888.902.6111
www.intellirentco.com
Display Pressure to Fluke 744 or 725 Differential, Gauge, Absolute, Vacuum, Dual and High Pressure Models Accuracy from 0.025%
Model 700P00 700P01 700P02 700P03 700P04 700P05 700P06 700P07 700P08 700P09 700P22 700P23 700P24 700P27 700P29
Range 1 H20 Differential 10 H20 Differential 1 PSID Differential 5 PSID Differential 15 PSID Differential 30 PSI Gauge
Model 700P30 700P31 700PA3 700PA4 700PA5 700PA6 700PD2 700PD3 700PD4 700PD5 700PD6 700PD7 700PV3 700PV4
Range 5K PSI High 10K PSI High 5 PSIA Absolute 15 PSIA Absolute 30 PSIA Absolute 100 PSIA Absolute +/- 1 PSI Dual +/- 5 PSI Dual +/- 15 PSI Dual -15/30 PSI Dual -15/100 PSI Dual -15/200 PSI Dual -5 PSI Vacuum -15 PSI Vacuum
100 PSI Gauge 500 PSI Gauge 1000 PSI Gauge 1500 PSI Gauge 1 PSID Differential 5 PSID Differential 15 PSID Differential 300 PSI Gauge 3K PSI High
Communicate with and Adjust HART, Fieldbus and Thousands of Other Devices Field Upgradeable and Intrinsically Safe Large LCD Touch Screen Menu Driven for Ease of Use and Quick Familiarization 32MB of Application Memory and Removable SD Card for Device Descriptions
89
Vacuum, Pneumatic, Dual Range and Hydraulic Hand Pumps for Any Application Provided by Intellirent complete with Tubing and Fitting Kits All Pumps are Available with an Appropriately Ranged Test Gauge for a Complete Pressure Calibration Kit Martel MECP500 Vacuum to 500PSI Pneumatic Hand Pump Reliable, No Maintenance Pneumatic Hand Pump Generates -28 Hg (-12 PSI) to 500 PSI in Real World Conditions Easy to Use Fine Release Bleed Value and Fine Adjust Vernier Martel MECP 100/V Vacuum to 100PSI Pneumatic Hand Pump Reliable, No Maintenance Pneumatic Hand Pump Generates -28 Hg (-12 PSI) to 100 PSI in Real World Conditions Simple, Compact Design Fine Release Bleed Value and Fine Adjust Vernier Martel MECP 10,000 10K PSI Hydraulic Hand Pump Reliable, Hydraulic Fluid or Water Hand Pump Generates 0-10K PSI in Real World Conditions Fully Adjustable Stroke Control Fine Release Bleed Value and Fine Adjust Vernier Ralston HPGV 3000 PSI Hydraulic Hand Pump Generates 3000 PSI in Real World Conditions Two Outlet Ports with Fine Adjustment Ralston DP0V Vacuum to 100 PSI Pneumatic Hand Pump Generate -25 Hg to 100 PSI In the Same Pump Switch from Pressure to Vacuum by Twisting A Knob Two Outlet Ports, Large Voltage Fine Adjustment Knob Vent and Bleed Valve
Measure 4-20mA Signals Without Breaking Loops 1/4 Jaw Opening 0.2% Accuracy Resolution of 0.01 mA
90
888.902.6111
www.intellirentco.com
0.05% F.S. Temperature Compensated Accuracy Displays in Eighteen Standard Pressure Units Displays Ambient Temperature Min/Max Recall Battery Operated User Configurable Sample Rate Maximizes Battery Life Ruggedized Case for Extended Use and Reliability Available from Intellirent in Multiple Ranges:
Range 0-100 PSI 0-1000 PSI 0-30 PSI 0-300 PSI -15 (Vacuum) -30 PSI 0-500 PSI 0-3000 PSI
Rugged and Dependable Accuracy of 0.1% Multiple Pressure Units Pressure Ranges from 15 to 10K PSI Battery Operated 1/4 NPT Connection
Model XP2i-15 XP2i-30 XP2i-100 XP2i-300 XP2i-500 XP2i-1K XP2i-1K XP2i-2K XP2i-3K XP2i-5K XP2i-10K
Range 15 PSI 30 PSI 100 PSI 300 PSI 500 PSI 1,000 PSI 1,000 PSI 2,000 PSI 3000 PSI 5000 PSI 10,000 PSI
Generates Pressures to 0.1% of Reading Range of 10,000 PSI for a Wide Variety of Applications Two Piston Construction, Low Pressure (from 15 to 2,000 PSI) and High Pressure (from 75 to 10,000 PSI)
91
Model Altek 820 Altek 334A Altek 422 Altek 311A Altek 942
Description Multifunction Process Calibrator Loop Calibrator Thermocouple Calibrator RTD Calibrator Frequency Calibrator
Altek Calibrators
Model PIE 334 PIE 532 PIE 541 PIE 211 PIE 525 PIE 322
Description Loop Calibrator Loop and Voltage Calibrator Frequency Calibrator with Totalizer RTD Calibrator Thermocouple and RTD Calibrator Thermocouple Calibrator
PIE Calibrators
Real Four Wire Substitution of RTDs at 0.01% Accuracy Six Decades for Precision Adjustment 10 to 111.110 Two, Three or Four Wire Connections
92
888.902.6111
www.intellirentco.com
Low and High Temperature Quick Cal Models Available Temperature Ranges from -12C to 350C 9 Minutes to Heating and Cooling Times to Obtain Temperature Set Point Lightweight at only 3.3lbs Interchangeable and Custom Inserts are Available Accuracy for the Low Temp Quick-Cal is 0.1 to 0.4C, Stability is 0.05C Accuracy for the High Temp Quick-Cal is 0.1 to 0.4C, Stability is 0.05C
Generates Temperatures From 35C to 650C Large Calibration Volume Heats From 30C to 650C in 20 Minutes Cools From 650C to 150C in 60 Minutes Computer Interface For Programmable Settings Optional Surface Sensor and Blackbody
Generates Temperature from -100C to 40C Cools to -20C in 20 Minutes Cools To -100C in 90 Minutes Stability of +/-0.03C at 0C
93
Index by Application
Index by Application
ABB Secondary Injection Test Set Absolute Pressure Module AC Hipot AC Pro Test Set Acoustical Detector Altek Amptector Test Set Astromed Attached Rod Technique Ground Tester Battery Analyzer Battery Discharge Analyzer Battery Ground Fault Tracer (BGFT) Battery Hydrometer Battery Impedance Test Set Battery Load Bank Biomedical Safety Analyzer Calibrator Capacitance and Insulation Analyzer Capacitance Bridge Chart Recorder Circuit Breaker Timer and Travel Analyzer Circuit Tracer Clamp On Ground Resistance Meter Clamp On Loop Calibrator Communications Adaptor CT Test Set Current Probe Cutler Hammer Secondary Injection Test Set Data Acquisition System DC Hipot Dead Weight Tester Decade Box Dewpoint Analyzer Dielectric Response Analyzer Differential Pressure Module Digitrip Power Supply Digitrip Test Set DILO DLRO Doble Documenting Multifunction Process Calibrator Dranetz Dry Block Calibrator DS and DS II Adaptor Dual Pressure Module Ductor ECS and SST Test Set Electrical Safety and Hospital Test Equipment Electrical Test Instruments (Manufacturer) 41, 42 89 53, 55 47 65 92 42, 43 6, 7 69 67 67 66 66 67 66 74 92 19 19 6, 7 48 65 69 90 17 22, 29 7, 73 42, 43 6, 7, 8 54 - 58 91 92 28 20 89 43 42, 43 49 22, 30, 31 18 88 3 93 42 89 30, 31 44 86 36, 37 EMax Test Set Entelliguard Test Set Fault Locator Fiber Optic Light Source and Power Meter Flexible Current Probe Frequency Calibrator Frequency Selective Voltmeter Function Generator GE Secondary Injection Test Set GPS Antenna Ground Tester Hand Pump Hart Communicator High Current Test Sets High Level VLF Signal Source High Voltage Circuit Breaker Test Equipment High Voltage Current Probe High Voltage Current Recorder High Voltage Probe Hipot Hydraulic Hand Pump Impedance Magnitude Meter Impedance Meter Infrared Camera Infrared Thermometer Insulation Analyzer Kyle/MET Test Set LCR Meter Leakage Current Meter Leakage Reactance Light Meter Line Carrier/Trap Tuning Equipment Line Isolation Monitor Tester Linear Transducer Load Bank (Battery) Loop Calibrator Low Voltage Circuit Breaker Test Equipment Magnum DS Adaptor Magnum DS Test Set Megohmmeters Merlin Gerin Secondary Injection Test Set MicroLogic Test Set MicroVersaTrip Test Set Motor Analyzer Motor Rotation Indicator MPS Test Set MPSC 2000 Test Set MPS-C Test Set Multi Gas Analyzer 41 44 61, 64, 65, 66 61 2-7 92 75 71 14 17 68, 69 90 89 34-39 75 48-53 73 73 73 54-58 90 75 22, 76 78, 79 82 18,19, 32, 33 44 76 61 18, 22 81 75 74 48 66 92 30-47 42 42 32, 33 45 45 44 84, 85 11, 84 41 42 41 86
94
888.902.6111
www.intellirentco.com
Multifunction Process Calibrator Multimeter Multipoint Ground Tester Multitap CT Test Set Oil Dielectric Test Set Optimizer Oscilloscope Partial Discharge Analyzer PDMA Phase Angle Meter Phase Sequence Indicator Phasing Kit Pneumatic Hand Pump Polarity Checker Power Factor Test Set Power Meter Power Multimeter Power Quality Analyzer Power Sensor Test Set Power Shield Test Set Power Supply Pow-R-Trip Test Set Pressure Gauges (Test Gauges) Pressure Modules Primary Injection Test Set Primary Test System Process Calibration Equipment Relay Test Jacks (Paddles) Relay Test Set Resonating Inductor Rotary Transducer Rotating Equipment Analyzer RTD Calibrator SACE Test Set Satin American ETC Test Set Satin American ETC.12 Adaptor SB Power Supply SB Test Set Secondary Injection Test Sets Seltronic Test Set Series C Test Set SF6 Connection Adaptors SF6 Detector SF6 Purity Analyzer SF6 Regulator Siemens Secondary Injection Test Set Single Phase Relay Test Set Single Phase TTR Smart Communicator
88 76 68, 69 29 27 43 9, 11 21 84 72 11 77 90 23 18, 19, 23 2-11 72 2-7, 9 44 41 22, 50 43 91 89 22, 34-39 22 88-93 17 12-17 60 48 85 92 41 46 46 47 46 40-47 42 42 49 49 49 49 46 16 22, 26, 27 89
Sound Level Meter Square D Secondary Injection Test Set Static Trip II and III Test Set STR Test Set Strobe Tachometer Sudden Pressure Relay Test Kit SureTrip Adaptor Sweep Frequency Response Analyzer Synch Scope Tachometer Tan Delta Analyzer Test Gauge Thermocouple Calibrator Three Phase Relay Test Set Three Phsae TTR Thumper Tic Tracer Time Domain Reflectometer Timer Tower Ground Tester Transducer Transformer Impedance Meter Transformer Ohmmeter Travel Analyzer UE Systems Ultrasonic Detector Underground Cable Locator and Tracer Utility Relay Secondary Injection Test Set Vacuum Bottle Test Set Vacuum Hand Pump Vacuum Pressure Module Vibration Analyzer Vibration Meter VL Test Set VLF Hipots Voltage Detector Voltage Probe Watthour Meter Pickups Watthour Meter Test System Watthour Standard Westinghouse Secondary Injection Test Set Winding Resistance Test Set WL Test Set Z Meter
81 45 46 45 83 28 47 19, 20 72 82, 83 56-58 91 92 12-15 27 64 87 64, 61 52 69 48 22 24 48 79 79, 80 65 47 53 90 89 83, 85 83, 85 47 55-58 87 77 70 71 70, 71 47 22, 24, 25 46 76
95
Index by Manufacturer
Index by Manufacturer
Manufacturer
ABB ABB ABB ABB ABB ABB ABB ABB AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC AEMC Agilent Alber Alber Altek Altek Altek Altek Altek Ametek Amprobe Amprobe Amprobe Amprobe Amprobe Amprobe Amprobe Amprobe Amprobe Amprobe Amprobe Amprobe Amprobe Aquatronics Ashcroft Astromed Astromed Astromed Astromed Astromed Astromed Astromed Astromed Astromed
Model
504 505 606 607 BTSB CB-10 PR010/T TT1 2620 3711 3731 3945 4620 5050 5060 6240 6250 6474 8335 JM865A MN103 MN254 MR410 MR521 SL201 SR600 1732B CellCorder CRT-400 422 820 942 311A 334A 1726 ACF-3000-DMA AT-2005 AT-3000 Pro CT600 DMCT DMCT100 DM-II Plus DM-III MultiTest DM-III MultiTest Flex Flex 33 H10A PRM-2 TIC300HV SDAD 1305D-100 DASH 18X DASH 8Xe DASH 8XPM HDV1 IBR1 IHV1 IHV3 ITCU IHV2
Page
40, 41 40, 41 40, 41 40, 41 40, 42 51 40, 41 40, 41 61 69 69 4 69 63 63 30 30 69 4 7 7 7 7 7 7 7 76 67 67 92 92 92 92 92 82 5 65 65 7 5 5 5 5 5 5 87 11, 74 87 65 91 7 7 6 6 6 6 6 6 6
Manufacturer
Baur Bender Cannon Cooper Power Systems Crystal Crystal Crystal Crystal Crystal Crystal Crystal Crystal Crystal Crystal Cutler Hammer Cutler Hammer Cutler Hammer Cutler Hammer Cutler Hammer Cutler Hammer Cutler Hammer Cutler Hammer Cutler Hammer Cutler Hammer Cutler Hammer Cutler Hammer DILO DILO DILO Doble Doble Doble Doble Doble Doble Doble Doble Doble Dranetz Dranetz Dranetz Dranetz Dranetz Dranetz Dranetz Dranetz Dranetz Dranetz Dranetz EA Technologies Electrical Test Instruments Electrical Test Instruments Electrical Test Instruments Electrical Test Instruments Electrical Test Instruments Extech Extech Extech Fluke
Model
Page
Frida 58 LT-3000 74, 86 L121-250 66 METK1 40, 44 XP2i-100 91 XP2i-10K 91 XP2i-15 91 XP2i-1K 91 XP2i-2K 91 XP2i-30 91 XP2i-300 91 XP2i-3K 91 XP2i-500 91 XP2i-5K 91 1232C50G05 40, 42 1232C50G10 40, 42 140D481G02 40, 43 140D481G03 40, 42 7801C56/MSTS120V 40, 43 7801C57 40, 43 8779C02G03 40, 42 8779C02G04 40, 42 MTK1000 40, 43 PRTAAPM 40, 43 PRTBAPMDV 40, 43 SPBPTK 40, 43 3-027-R002 49 3-033-R002 49 DN8/DN20 49 F2010 16 F2253 16 F2700 16 F6150 15 F6895 17 M4000 18, 51, 60, 84 M4110 18 M5400 19 Type C 60, 84 3000XL24 3 3000XL36 3 3000XL48 3 6000XL24 3 6000XL36 3 6000XL48 3 Dranview 3 Dranview Enterprise Edition 3 PX5 3 TR-2500 3 TR-2510 3 UltraTev + 21, 52, 80 PI-1600 37 PI-2500 37 PI-4000 37 PI-5000 37 PI-800 37 407736 81 480823 82 EA30 81 63 82
96
888.902.6111
www.intellirentco.com
Manufacturer
Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke Fluke GE GE
Model
124 125 196 434 435 725 744 771 789 810 1750 2686 3005 3014 3110 3210 3310 9141 43B 700P00 700P01 700P02 700P03 700P04 700P05 700P06 700P07 700P08 700P09 700P22 700P23 700P24 700P27 700P29 700P30 700P31 700PA3 700PA4 700PA5 700PA6 700PD2 700PD3 700PD4 700PD5 700PD6 700PD7 700PV3 700PV4 87 V FAI FOM FOS I-2000 PAI Ti32 Ti45 Ti55 GTUTK20 PST1-1
Page
9, 71 9, 71 11 9 9 88 88 90 76, 88 85 3 8, 67 3 3 3 3 3 28 9 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 76, 88 8, 67 61 61 7 8, 67 79 78 78 40, 44 40, 44
Manufacturer
GE GE GE GE Multilin General GW Instek Hart HD Electric High Voltage High Voltage High Voltage High Voltage High Voltage High Voltage High Voltage Hipotronics HV Diagnostics HV Diagnostics HV Diagnostics HV Diagnostics Innovative Utility Products Isotech Isotech Isotech Magna IV Manta Manta Martel Martel Martel Martel Martel Martel Martel Martel Martel Martel Megger Megger Megger Megger Megger Megger Megger Megger Megger Megger Megger Megger Megger Megger Megger Megger Megger Merlin Gerin Metrel Metrel Metrel Metrel
Model
TAKTS1 TVRMS2 TVTS1 F485 DCS-1800 GFG-8255A 375 DVM-II PFT-303CM PFT-503CM PTS-130 PTS-200 PTS-75 PTS-80 VLF-6022CM OC60D HVA30 HVA60 TD-30 TD-60 Fault Wizard ISIS Jupiter Quick-Cal 550 PS12/480 MTS-1030 MTS-5000 MECP 100-V MECP 10K MECP 500 PI 100 PI 1000 PI 30 PI 300 PI 3000 PI 500 PI C-V 210415 246100B BGFT CB-100 CB-845 CFL535 DDA-3000 DDA-6000 DET20C DET3TC DLRO600 I Clamp MS-2 PMM-1 S1-1052 S1-552 SMRT36 34547 2077 2088 3121 3123
Page
40, 44 40, 44 40, 44 17 81 71 89 77, 87 53 53 54 55 54 54 55 27 56 57 56 57 64 93 93 93 50 10, 72 12 90 90 90 91 91 91 91 91 91 91 33, 63 66 66 19, 51 39 61 39 39 69 69 31 69 34 10, 72 33 33 14 40, 45 32, 62 68 32, 62 68
97
Index by Manufacturer
Index by Manufacturer
Manufacturer
Metrel Metrel Monarch Ohmic Omicron Omicron Omicron Omicron Omicron Omicron Omicron PDMA Phenix Phenix Phenix PIE PIE PIE PIE PIE PIE Proflex Programma Programma Qualitrol Radian Radian Radian Radian Radian Radian Radian Radian Radian Radian Radian Ralston Ralston Raytech Raytech Raytech Raytech Raytech Raytech Raytech Raytech Rion RKI RKI Satin American Satin American SBS Sencore Sensorlink Sensorlink Sensorlink Siemens Siemens Siemens
Model
3200 3201 Nova Strobe DB BET300AD CMC 356 CP CB2 CP TD1 CPC 100 CPOL DIRANA FRAnalyzer MCEMax 6CP-100-7.5 HC-1 HC-2 211 322 334 525 532 541 ACP 3000 Tridra Sverker 760 TM200 KIT-013-1 RD-21-112 RM-111 RM-1Hz RM-1S RM-KYZ RR-1H RR-1HV RR-DS RR-DS RR-KYZ RRKYZ-2 DP0V HPGV Micro Centurion II Micro Junior II TR-1 T-Rex TR-SPY Mark II TR-SPY Mark III WR-14 WR-50-12 VM-82 GX-2003 GX-2009 ETC.12 Adaptor ETC-PTS 2002 LC53 6-920 Amp LiteWire Volt LiteWire PTS-4 PTS-5 SBAPM
Page
33, 63, 85 32, 62 83 11, 74, 86 13 23, 38 23 22, 38 23 20 20 84 55 35 35 92 92 92 92 92 92 3 14 52 28 70 70 70 70 70 70 70 70 70 70 70 90 90 31 30 26 26 26 27 24 24, 85 83 86 86 40, 46 40, 46 66 76 10, 73 73 73 40, 46 40, 46 40, 47
Manufacturer
Siemens Siemens Siemens Siemes SignalCrafters SignalCrafters SignalCrafters SPM SPM Square D Square D Square D Square D Square D Square D Summit SureTrip Transcat Transdata Tristate UE Systems Utility Relay Co Vaisala Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vanguard Vitrek Westinghouse Westinghouse
Model
TS-31 WL Full Function WLTS ELTPHB 60 90 110 VIB-10 VIB-11 CBTM3 CBTM4A CBTMB S33594 S33595 UTS-3 15kVP CON1111 7010T 2130 TSW45 UltraProbe 100 1-AC-PRO-TS DM70 ATRT-03 SII Auto Ohm SII CT-6500 SII DIGITIMR EZCT EZCT-10 EZCT-2000A EZCT-2000B LT-10 LT-24 MCCB-250 PCI-600 RT-DT1 RT-HMA RT-HMB RT-Mag RT-PM Transducers UPS S-2 VBT-60 VBT-80 WRM-10 WRM-10P WRM-40 V61 PI-161 SCBII
Page
40, 46 40, 47 40, 46 40, 47 75 75 75 83 83 40, 45 40, 45 40, 45 40, 45 40, 45 40, 45 77 40, 47 92 71 77 79 40, 47 28, 50 27 31 48 48 29 29 29 29 48 48 34 35 48 48 48 48 48 48 50 53 53 25 25 25 87 72 40, 47
98
888.902.6111
www.intellirentco.com
T 972.317.0479
www.intellirentco.com
contact us at info@intellirentco.com
604 Henrietta Creek Suite 400 Roanoke, TX 76262 T 888.902.6111 T 972.317.0479 F 817.491.0068 intellirentco.com info@intellirentco.com