Characteristics

31630

circuit breaker Compact NS250N - TMD - 250 A - 3 poles 3d

Main
Device short name Circuit breaker name Circuit breaker application Poles description Protected poles description Network type Network frequency [In] rated current [Ui] rated insulation voltage [Uimp] rated impulse withstand voltage [Ue] rated operational voltage Circuit breaker rating code Breaking capacity Compact NS250N Compact NS250N Distribution 3P 3t AC DC 50/60 Hz 220 A 65 C 250 A 40 C 750 V IEC 60947-2 AC 50/60 Hz 8 kV IEC 60947-2 690 V IEC 60947-2 AC 50/60 Hz 750 V IEC 60947-2 DC N 8 kA Icu IEC 60947-2 660/690 V AC 50/60 Hz 18 kA UL 508 600 V AC 50/60 Hz 20 kA NEMA AB1 HIC 600 V AC 50/60 Hz 22 kA Icu IEC 60947-2 525 V AC 50/60 Hz 30 kA Icu IEC 60947-2 500 V AC 50/60 Hz 35 kA Icu IEC 60947-2 440 V AC 50/60 Hz 35 kA UL 508 480 V AC 50/60 Hz 35 kA NEMA AB1 HIC 480 V AC 50/60 Hz 36 kA Icu IEC 60947-2 380/415 V AC 50/60 Hz 85 kA Icu IEC 60947-2 220/240 V AC 50/60 Hz 85 kA UL 508 240 V AC 50/60 Hz 85 kA NEMA AB1 HIC 240 V AC 50/60 Hz 8 kA IEC 60947-2 660/690 V AC 50/60 Hz 22 kA IEC 60947-2 525 V AC 50/60 Hz 30 kA IEC 60947-2 500 V AC 50/60 Hz 35 kA IEC 60947-2 440 V AC 50/60 Hz 36 kA IEC 60947-2 380/415 V AC 50/60 Hz 85 kA IEC 60947-2 220/240 V AC 50/60 Hz Yes IEC 60947-2 Category A TM-D Thermal-magnetic 250 A 40 C Overload protection (thermal) Short-circuit protection (magnetic) 3 IEC 60947

[Ics] rated service breaking capacity

Suitability for isolation Utilisation category Trip unit name Trip unit technology Trip unit rating Protection type Pollution degree

Complementary
Control type Mounting mode Mounting support Upside connection Downside connection Mechanical durability Toggle Fixed Backplate Front Front 20000 cycles

Dec 6, 2011

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Electrical durability Connection pitch Local signalling Long time pick-up adjstment type Ir Long time pick-up adjustment range Instantaneous pick-up adjustment type Ii Instantaneous pick-up adjustment range Height Width Depth

10000 cycles IEC 60947-2 440 V In AC 50/60 Hz 20000 cycles IEC 60947-2 440 V In/2 AC 50/60 Hz 35 mm Positive contact indication Adjustable 0.8...1 x In Adjustable 5...10 x In 161 mm 105 mm 86 mm

Environment
Standards Product certifications IEC 60947-2 ASEFA ASTA KEMA LCIE IP40 IEC 60529 IK07 EN 50102 -25...70 C -50...85 C 0826 Compliant

IP degree of protection IK degree of protection Ambient air temperature for operation Ambient air temperature for storage RoHS EUR conformity date RoHS EUR status