Alcatel BTS EVOLIUM A9100

FIROSE PADATH - INTELTEC 11 INTELTEC EMIRATES

Logical position of BTS in BSS

FIROSE PADATH - INTELTEC

22

Functional Architecture of BTS

FIROSE PADATH - INTELTEC

33

Introduction of Alcatel BTS


FIROSE PADATH - INTELTEC 44 INTELTEC EMIRATES

Indoor BTS

BTS Circuit Breakers (BCB) Network Interface Card Shelf # 5

External Alarm Circuit Board (EACB)

Combiners Shelf # 4

TRE

Shelf # 3

Shelf # 2

SUMA Card

Shelf # 1

FIROSE PADATH - INTELTEC

55

Interconnection Area BTSCA

External Alarm Circuit Board (EACB)

Network Interface Card

BTS Circuit Breakers (BCB)

FIROSE PADATH - INTELTEC

66

BTS Circuit Breakers (BCB)

FIROSE PADATH - INTELTEC

77

External Alarm Circuit Board (EACB)

FIROSE PADATH - INTELTEC

88

Network Interface Card

Abis 1

FIROSE PADATH - INTELTEC

99

The Abis Interface connects the BTS A9100 to the BSC. There are four connectors, these are Abis 1, 2, 3 and 4. Only Abis 1 and 2 are currently used; Abis 3 and 4 are provided for future use. Abis Relays - Four relays, one for each Abis Interface, are controlled by the SUM

FIROSE PADATH - INTELTEC

1010

ANC Module Antenna Network Combiner


Equipment Label

Lock Fastener

Module Extractor

Transmitter Connector

Antenna Connector

Receiver Connector

FIROSE PADATH - INTELTEC

1111

Click to edit Master text styles Second level Third level Fourth level Fifth level

The ANC (Antenna Network Combiner) provides the intermediate RF stage between the TREs and the antenna. Its tasks are to: - Combine the output signals of up to four transmitters and to connect them to up to two antennas - Feed the received signals from the antenna to the radio front end, where the signals are amplified and distributed to up to eight receivers - Allow simultaneous transmission and receiving on antennas (duplexer)

- Provide filtering for the TX- and RX-path FIROSE PADATH - INTELTEC 1212

Click to edit Master text styles Second level Third level Fourth level Fifth level

On the downlink, the ANC connects two TRE transmitters to two antennas. On the uplink, it splits the received signals and passes them to the TRE receivers. ANCG, ANC module for GSM 900 ANCD, ANC module for GSM 1800

FIROSE PADATH - INTELTEC

1313

Lock Fastener

ANY Module
Equipment Label

Transmitter Connector

Receiver Connector

Module Extractor

Antenna Connector

FIROSE PADATH - INTELTEC

1414

ANY Module

The ANY is a passive RF module, having neither a controller nor a power supply. It is an optional RF distribution device, which is used to expand the capacity of the ANX/ANC. Therefore, it is basically an extension unit to the ANX/ANC module. ANYG, ANY module for GSM 900 ANYD, ANY module for GSM 1800

FIROSE PADATH - INTELTEC

1515

ANY Module

The Twin Wide Band Combiner stage (ANY) combines up to four transmitters into two outputs, and distributes the two received signals up to four receivers Twin Wide Band Combiner module (ANY) is only necessary for sectors with five or more TRXs

FIROSE PADATH - INTELTEC

1616

TRE Module
Module Extractor Transmitter Connector ON/OFF Switch Equipment Label

USB Test Connector Receiver Connector

LEDs Lock Fastener

FIROSE PADATH - INTELTEC

1717

TRE Module

FIROSE PADATH - INTELTEC

1818

TRE Module

The TRE performs the digital functions interface to the SUM and the analog functions interface to the AN module Interface Test Provides an interface to the TRE for factory test purposes. TX Provides the transmit RF Interface to the AN module. RX 0, RX 1 Provides two receive RF Interfaces from the AN module. FIROSE PADATH - INTELTEC 1919

SUMA/SUMP -Station Unit Module


Abis Connector

BTS Connection Area Connector

Equipment Label BTS Terminal Connector Test Connector USB Connector

LEDs

Lock Fastener

FIROSE PADATH - INTELTEC

2020

SUMA/SUMP

FIROSE PADATH - INTELTEC

2121

The SUMP/SUMA provides the central management and control of all the BTS A9100 modules. It is responsible for the following functional areas: -Digital transmission -Timing and clock generation -Management of the BTS internal digital interfaces O and M functions The SUMP/SUMA provides a switchable 2 Mbit/s duplex connection between the Abis Interface and the BSII. The BSII is used to transfer TCH information to the TRE module, and O and M information to the OMU/SUM microprocessor.
The Abis Interface is the digital interface to the BSC

The Q1 link is a logical link routed via the Abis Interface, the Time Slot Switch, the BSII switch and the BSII to the O and M functions. The O and M functions are performed remotely by the BSC TSC, via the Q1 link, or locally via aBTS Terminal. All BTS A9100 transmission equipment have Q1 addresses, which identify them to the TSC.
The BSII is an internal digital interface to the TRE module

FIROSE PADATH - INTELTEC

2222

SUMA Card Basic Architecture

FIROSE PADATH - INTELTEC

2323

Remote Inventory Cable (RI Cable)

FIROSE PADATH - INTELTEC

2424

Remote Inventory Cable (RI Cable)

FIROSE PADATH - INTELTEC

2525

Cabinet Cooling Fan

FIROSE PADATH - INTELTEC

2626

Connect to Alcatel BTS Using BTSTerminal


FIROSE PADATH - INTELTEC 2727

User Name (COMMTE)

Password (COMMTE)

FIROSE PADATH - INTELTEC

2828

Press Baud rate button to set it

FIROSE PADATH - INTELTEC

2929

Select the appropriate COM Port

Select Baud rate = 19200

FIROSE PADATH - INTELTEC

3030

Press F2 OR Connect/Disconnect button OR File>Connect/Disconnect from menu

FIROSE PADATH - INTELTEC

3131

Menu bar will be changed on establishing successful connection

Following windows will open on establishing successful connection

FIROSE PADATH - INTELTEC

3232

Monitor Active Alarm

External Active Alarms Show Here

FIROSE PADATH - INTELTEC

3333

Show Hardware Configuration (Ctrl H)

Select All

Select Appropriate Module

Select OK

FIROSE PADATH - INTELTEC

3434

SUMA Card = OMU 1

Rack A (BTS Cabinet # 1)

Shelf # 2

Slot # 7

FIROSE PADATH - INTELTEC

3535

SBL Module States (F5)

SBL Module States (F5) Antenna 1=B

Antenna 0=A

RA 1= Combiner 1 Sector A

VSWR Value=1.1 VSWR Value=1.2

FIROSE PADATH - INTELTEC

3636

SBL Management SBL Management

Read

Initializ e

Select Module

FIROSE PADATH - INTELTEC

Reset

Disable Restart

3737

Execution Result

Selected Module Type

State of the Module (NEQ/OPR/IT)

FIROSE PADATH - INTELTEC

3838

Modify Hardware Configuration

Remove Module

End Modification of HW Configuration

Select Module to Remove

FIROSE PADATH - INTELTEC

3939

Following window appears (Cabling Detection in Progress)

Click Yes

FIROSE PADATH - INTELTEC

4040

OFF Line Commissioni ng Procedure


FIROSE PADATH - INTELTEC 4141

Switch OFF the BTS cabinet and disconnect Abis connectors from DDF before offline start

FIROSE PADATH - INTELTEC

4242

Disconnect the Abis connector from The DDF

FIROSE PADATH - INTELTEC

4343

Switch ON the BTS cabinet breakers and connect the Laptop at the BTS Terminal using MMI Cable

FIROSE PADATH - INTELTEC

4444

User Name (COMMTE)

Password (COMMTE)

FIROSE PADATH - INTELTEC

4545

Press F2 OR Connect/Disconnect button OR File>Connect/Disconnect from menu

FIROSE PADATH - INTELTEC

4646

Menu bar will be changed on establishing successful connection

Following windows will open on establishing successful connection

FIROSE PADATH - INTELTEC

4747

Restore Default

Warning Window appears Click OK to Restore SUMA Card

FIROSE PADATH - INTELTEC

4848

Verify Qmux address Press Yes to change it Confirm Qmux address from OMCR first FIROSE PADATH - INTELTEC

4949

Go to Commissioning->Download>BTS-SW to download BTS software

FIROSE PADATH - INTELTEC

5050

Edit New Qmux address Press Put button to update

FIROSE PADATH - INTELTEC

5151

Updating Qmux address

FIROSE PADATH - INTELTEC

5252

Press Browse to select the path of BM1SAW19.MSF file

Press Browse to select the path of AGC3AVWa.DDL file

Path Selection Window

FIROSE PADATH - INTELTEC

5353

Software download in Progress It may take up to 30 minutes

FIROSE PADATH - INTELTEC

5454

Initialization window open when download complete

FIROSE PADATH - INTELTEC

5555

Receiving data window open

FIROSE PADATH - INTELTEC

5656

Select appropriate option from Frequency Brand dropdown menu 1- Select GSM for GSM cabinet 2- Select DCS1800 for DCS cabinet 3- Select GSM for GSM+DCS (Combined) cabinet

FIROSE PADATH - INTELTEC

5757

Dont uncheck Bridge check option and dont change Sectors numbers Press Save button in Sector mapping window

FIROSE PADATH - INTELTEC

5858

Updating flash

FIROSE PADATH - INTELTEC

5959

Press Save in TMA Setting window

FIROSE PADATH - INTELTEC

6060

Press Settings->Transmission->Initial Settings

FIROSE PADATH - INTELTEC

6161

Check Line impedance for Abis1 & Abis2 = 75ohm

Reconfirm the Qmux address Verify Environment Abis1 = Chain end position

Verify Baud Rate = 1200

Verify CRC Check = ON

FIROSE PADATH - INTELTEC

6262

Press Settings->Transmission->Board Settings

FIROSE PADATH - INTELTEC

6363

Uncheck all TREs press Transmit button

FIROSE PADATH - INTELTEC

6464

Press Commissioning->Initialization->All Sectors to initialize BTS

FIROSE PADATH - INTELTEC

6565

Initialization of Commissioning in progress

FIROSE PADATH - INTELTEC

6666

Press Commissioning->Station Unit Test for Station Unit Test

FIROSE PADATH - INTELTEC

6767

Select Internal Loop

FIROSE PADATH - INTELTEC

6868

Station Unit Test in progress

FIROSE PADATH - INTELTEC

6969

Following Results on successful completion

FIROSE PADATH - INTELTEC

7070

Select External Loop (Make Sure that the Abis # or 2 must be looped at DDF

FIROSE PADATH - INTELTEC

7171

Abis # 1 Loop test failed because Abis # 1 not Looped at DDF

Result window appears

FIROSE PADATH - INTELTEC

7272

Now switch on the BTS cabinet breakers and through the site

FIROSE PADATH - INTELTEC

7373

Reconnect the Abis connector at DDF by verifying the TX/RX cables properly

Reconnect the Abis connector at DDF by verifying the TX/RX cables properly

FIROSE PADATH - INTELTEC

7474

OFF Line Commissioning is Done Successfully

FIROSE PADATH - INTELTEC

7575

AN

Antenna Network B BCB BTS Control Bus BSII Base Station Controller BSS Base Station Subsystem BTS Base Station Transceiver BTSW BTS-Terminal for Windows
FIROSE PADATH - INTELTEC 7676

Alcatel Glossary A

C CCF Cabinet Cooling Fan CDM Configuration Data Message CLEI Common Language Equipment CLLK Clock Link CPF Configuration Parameter File CRC Cyclic Redundancy Check CU Carrier Unit
FIROSE PADATH - INTELTEC 7777

Alcatel Glossary

Alcatel Glossary
D DC Direct Current DMA Deferred Maintenance Alarm E EQU Equipped

FIROSE PADATH - INTELTEC

7878

F FIA Format Identifier for Application part of RI FIM Format Identifier Manufacturing FIT Faulty In Traffic FLT Faulty FOS Faulty Out of Service
FIROSE PADATH - INTELTEC

Alcatel Glossary

7979

I ICS Item Change Status IT In Traffic L LDA Local Defence Action LRA Local Recovery Action

Alcatel Glossary

FIROSE PADATH - INTELTEC

8080

MI MSA MSD NEQ NOP

M Maintenance Information MSD Auto Maintenance Seized N Not Equipped Not Operational
FIROSE PADATH - INTELTEC 8181

Alcatel Glossary

O O&M Operation and Maintenance OMU Operation and Maintenance Unit OMUA OMU A RIT OMUB OMU B RIT OP Operational OPR Operator
FIROSE PADATH - INTELTEC 8282

Alcatel Glossary

P PADD Physical Address PMA Prompt Maintenance Alarm R RA Radio Access RF Radio Frequency RFH Radio Frequency Hopping ( also known as : Synthesizer Hopping ) RI Remote Inventory RIT Replaceable Item RX Receiver or receive ..... RTC Remote Tunable Combiner
FIROSE PADATH - INTELTEC 8383

Alcatel Glossary

S SBL Security Block Level SCFE Station Unit Control Function Entity RIT SOS System Out of Service SUM Station Unit Module SUMP SUM PCM RIT SW Software
FIROSE PADATH - INTELTEC 8484

Alcatel Glossary

T TLV Tag, Length, Value TRE Transceiver Module (combined Transmitter / Receiver functionality for base band and RF signals) TS Timeslot TX Transmitter or transmit .....
FIROSE PADATH - INTELTEC 8585

Alcatel Glossary

VPMA VSWR WBC WTC XBCB XCLK XIOB

V Very Prompt Maintenance Alarm Voltage Standing Wave Ratio W Wide Band Combiner Wait Traffic Clear X External BCB External Clock External Input Output Board
FIROSE PADATH - INTELTEC 8686

Alcatel Glossary

The End Firose Padath Inteltec

FIROSE PADATH - INTELTEC

8787