temperature
Figure 1.1: Open-loop control of a room heating system will be measured by a temperature sensor and fed into a control device. In the case of ( disturbance ) the control device adjusts the heating flow
of Figure 1.2 using the motor M and the valve V. The slope of this is changed by opening a
characteristic can be tuned at the control device. If the room temperature window ( disturbance
) this will not influence the position of the valve, because only the outdoor
temperature will influence the heating flow. This control principle will not compensate the effects of all disturbances.
Figure 1.2: Characteristic of a heating control device for three different tuning sets (1, 2, 3) In the case of closed-loop control of the room temperature as shown in Figure 1.3 the room temperature is measured and compared with the set-point value , (e.g. ). If the room temperature deviates
1 of 3
1/4/2012 5:27 AM
http://www.atp.ruhr-uni-bochum.de/rt1/syscontrol/node4.html Generated by Foxit PDF Creator Foxit Software http://www.foxitsoftware.com For evaluation only.
from the given set-point value, a controller (C) alters the heat flow
, e.g. caused by opening the window or by solar radiation, are detected by the controller and removed.
Figure 1.3: Closed-loop control of a room heating system The block diagrams of the open-loop and the closed-loop temperature control systems are shown in Figures 1.4 and 1.5, and from these the difference between open- and closed-loop control is readily apparent.
Figure 1.4: Block diagram of the open-loop control of the heating system
Figure 1.5: Block diagram of the closed-loop control of the heating system The order of events to organise a closed-loop control is characterised by the following steps: Measurement of the controlled variable , Calculation of the control error (comparison of the controlled variable with the set-point the control error is value ), Processing of the control error such that by changing the manipulated variable
2 of 3
1/4/2012 5:27 AM
http://www.atp.ruhr-uni-bochum.de/rt1/syscontrol/node4.html Generated by Foxit PDF Creator Foxit Software http://www.foxitsoftware.com For evaluation only.
reduced or removed. Comparing open-loop control with closed-loop control the following differences are seen: Closed-loop control shows a closed-loop action (closed control loop); can counteract against disturbances (negative feedback); can become unstable, i.e. the controlled variable does not fade away, but grows (theoretically) to an infinite value. Open-loop control shows an open-loop action (controlled chain); can only counteract against disturbances, for which it has been designed; other disturbances cannot be removed; cannot become unstable - as long as the controlled object is stable. Summarising these properties we can define: Systems in which the output quantity has no effect upon the process input quantity are called open-loop control systems. Systems in which the output has an effect upon the process input quantity in such a manner as to maintain the desired output value are called closed-loop control systems.