Sie sind auf Seite 1von 3

MRP-15 < Version 3.

1> SETUP
Instruction Display Note 1. Press [CHANGE] key and WEIGHT: 98-04 switch on the scale at the UNIT PRICE: 3.1 same time. Do not release your hand from TOTAL PRICE: -1[CHANGE] key till display shows the version of scale.

1. Setup the weight unit:


Press the following keys while LCD shows [98-04] [3.1] [-1-] Key in: 1 2 3 4 0 Function: Power on the scale at Kg weight units Power on the scale at Lb weight units Power on the scale at Oz weight units Power on the scale at 100g weight units Show internal A/D Value (Press [CHANGE] key to re-boot the scale)

2. Setup the decimal point in Total Price Display.


While LCD shows [98-04] [3.1] [-1-]: Key in: [UNIT SET] [TARE/ZERO] [0] [UNIT SET] [TARE/ZERO] [1] [UNIT SET] [TARE/ZERO] [2] Decimal Point on Total Price Display: None 0.0 0.00

3. Setup the primitive data for IC93C46


While LCD shows [98-04] [3.1] [-1-], please press [CE] key for 3 ~ 5 seconds, and then follow the instructions as below: Instructions: Descriptions

1. Key in [1] [1] [0], and then the scale will enter 010 means MRP-15kg / 5g Calibration Mode automatically. 2. Please calibrate the scale (refer to the instructions of calibration on next page)

!! Notice: After re-setting the data for IC93C46, the scale will work under Lb weight units. Please remember to change the weight units into Kg.

Weight Calibration
Instructions 1. Power on the scale, and wait till Display shows 0. 2. Press [CHANGE] key and hold till Display shows SETUP. 3. Press [] once to enter calibration mode. 4. Press [CE] key to select the V figure (0 ~ 10). If you use a 5kg standard weight, please select 3. Display [0.000] [0] [0] SETUP -CALEnter SETUP mode Enter calibration mode V Figure = Capacity/ Standard Weight Example: GRP-15Kg / 5g Standard Weight: V figure: 5kg 3 15kg 1 Descriptions

5. Press [CHANGE] key to confirm the V figure. And then Display will show CAL-1 Internal Offset Value. 6. Press [CHANGE] key again while the Offset Value is stable. And then Display will show CAL20 7. Put the standard weight on he platter. And then Display will show Span Value. 8. Press [CHANGE] key twice when the Span Value is stable. And then the scale will re-boot automatically. Notice!! Please remove the standard weight from the platter while the scale is re-booting.

CAL-1 XXXX CAL-2 0

XXXX Finish setting the data for IC93C46.

Data-Lose: Err-1
1. After switching on the scale, if Display shows [0098] [0400] [Err-1], please key in [0] [1] [0] directly, and then the scale will enter Calibration Mode automatically.

2. If the scale does not enter Calibration Mode, please change a new IC93C46. 3. If the scale cannot be calibrated normally, please make sure if the battery is already undervoltage.

Recharge the Battery


1. TOTAL PRICE Display shows oo: Please recharge the battery.

2. The scale sounds BiBiBiBiBiBi three times and three LCD Displays show - - - - - continuously: The battery has completely run down. Please recharge the battery immediately.

3. Charging Indicator LED: LED in red light: the battery is under recharging. LED in green light: the battery is full.