Sie sind auf Seite 1von 4

Eu ro

nI tro

nstru m

ISO 9001
ua
lity Grant

e en

s ts

MicroCal T series

eurotron
"Excellence in measurements"

Portable Temperature Calibrators


Bulletin 09-06.3 E

TEST & MEASUREMENTS

Ranges from -50C to 1100C High stability and uniformity Fast cool-down design Microprocessor temperature controller RS232 serial interface CalpMan 2000 documenting PC software

Eurotron - One of the leaders in high technology equipment: high accuracy calibrators - non-contact IR thermometers - portable flue gas analyzers.

TEST & MEASUREMENTS

Portable Dry-block and Fluid Temperature Calibrators

GENERAL
The temperature parameter represent the most important factor to fulfil quality, operational safety and reliability of industrial processes. Thermocouples, RTDs and any other temperature sensors, when installed in a industrial process, they are subjected to mechanical, thermal and chemical stresses which accelerate their ageing. Therefore it is a recommended procedure to inspect, check and calibrate each sensor during the commissioning phase and at regular and programmed time intervals. The temperature calibrators series MicroCal T include five different, rugged and transportable units designed to obtain a controlled temperature with high stability, high uniformity in all calibrators ranges. Internal block temperature stability A built-in microprocessor based controller handle the man-machine interface, the internal logic and assures the high stability of the internal metal block through a sophisticated temperature algorithm. A complete Automatic Calibration System The MicroCal T can be used together with a Personal Computer, a multifunction high precision calibrator MicroCal 200/200+ (see bulletin 08-44) and a CalpMan 2000 Windows software package to improve a true automatic temperature calibration system. Using the RS232 interfaces of the instruments it is possible to program trough the PC the complete test procedure for Your thermocouple or resistance thermometer to be certificate. The MicroCal 200 is able to read the testing thermo-element with the desired accuracy and the software calculate the errors and prepare the certificate.

MicroCal T100
Compact, rugged and easy to use. Built-in reference Pt100 with high accuracy 0.01C resolution indicator Auxiliary inputs for external Pt100 and thermostat switch-test. Internal fan and Peltier unit for fastcool-down. RS232 serial interface and optional CalpMan 2000 WindowsTM software

MicroCal T350
Designed for Testing and calibrating temperature sensors Switch test input for thermostat Compact, rugged, and easy to use Microprocessor temperature controller optional RS232 serial interface and CalpMan 2000 WindowsTM software

ORDERING CODE Cat. 8172 - A - B - C


Table A 0 1 4 Table B 1 2 3 4 5 Table C 1 Options None Alluminium carrying case + EE460010, EE460013 and EE460015 inserts + extration tool Vinyl carrying case Power supply 120 V USA plug 230 V Schuko plug 240 V UK plug 230 V European plug 100 V Japan/USA plug Report of calibration Eurotron Report

NEW !

ORDERING CODE Cat. 8150 - A - B - C


Table A 0 1 3 4 5 Table B 1 2 3 4 Table C 1 Options None Carrying case RS232 serial interface blank insert 2 holes insert ( 6.5 - 12.5 mm) Power supply 120 V USA plug 230 V Schuko plug 240 V UK plug 230 V European plug Report of calibration Eurotron Report

TEST & MEASUREMENTS

A wide range of applications

MicroCal T500
Operating range from Tamb to +600.0 C Built-in reference Pt100 with high accuracy 0.01C resolution indicator. Auxiliary input for external Pt100. Thermostat switch-test input. Internal fan for rapid cool-down. RS232 interface and optional CalpMan 2000 WindowsTM software

MicroCal T1100
Temperature sensors field and laboratory inspection and calibration. Optional 2 inputs for external 3/4 wires Pt100 and Tc J, K, N, R, S. Thermostat switch-test input. Internal fan for rapid cool-down. Operating range from +200 C to +1100 C RS232 interface and optional CalpMan 2000 WindowsTM software ORDERING CODE Cat. 8176 - A - B - C
Table A 0 2 9 Table B 1 2 3 4 5 Table C 1 Options None n.2 Tc & Pt100 inputs Special drilling for 44mm block Power supply 120 V USA plug 230 V Schuko plug 240 V UK plug 230 V European plug 100 V Japan/USA plug Report of calibration Eurotron Report

MicroCal T200 Fluid


Operating range: Environment to +200C Optional 2 inputs for external 3/4 wires Pt100 and Tc J, K, N, R, S. Thermostat switch-test input. RS232 interface and optional CalpMan 2000 WindowsTM software. Water (<90C), 47V20 Silicon oil (<120C) and 47V100 Silicon oil (<200C).

ORDERING CODE Cat. 8174 - A - B - C


Table A Options 0 None 1 Alluminium carrying case + EE460016 and EE460017 inserts + extration tool 2 Maximum temperature +600C 4 Vinyl carrying case 7 Special drilling for 50mm block (550C) 7X Special drilling for 65mm block (550C) 8 Special drilling for 50mm block (600C) 8X Special drilling for 65mm block (600C) Table B 1 2 3 4 5 Power supply 120 V USA plug 230 V Schuko plug 240 V UK plug 230 V European plug 100 V Japan/USA plug

ORDERING CODE Cat. 8152 - A - B - C


Table A 0 1 2 Table B 1 2 3 4 Table C 1 Options None Vinyl carrying case n.2 Tc & Pt100 inputs Power supply 120 V USA plug 230 V Schuko plug 240 V UK plug 230 V European plug Report of calibration Eurotron Report

Table C Report of calibration 1 Eurotron Report

NEW !

TEST & MEASUREMENTS

What you need you can find here

Specifications
Model MicroCal T350 MicroCal T200 Fluid -50 from amb. to 150 amb. to 200 0,03 0,02 @150C 0,1 (100C) 0,2 (80 mm) Audio+Visual 0,15 0,1 / 0,01 Std. (Pt 100) C/F RS 232 20 C / min. 25 C / min. Standard 135
2 wells: 1 at 6.5mm, 1 interchangeable

MicroCal T100

MicroCal T500 amb. to 550 (600) 0,05 @ 450 C 0,2 (450C) 0,8 (80 mm) Audio+Visual 0,3 0,1 / 0,01 Std. (Pt 100) C/F RS 232 20C/ min. 25C/ min. (100C) Standard 185
4 wells: 1 at 4.5mm, 1 at 6.5mm, 1 at 9.5mm, 1 interchangeable

MicroCal T1100 200 to 1100* 0,3 @ 1000C 0,4 0,4 Audio+Visual 3 0,1 / 0,01 opt. (Pt 100 & Tc) C/F RS 232 18 C / min. 6 C / min. Standard 225
1 interchangeable

Temp. range C amb. to 350 Stability C 0,1 Uniformity Radial 0,5 Axial Stability indicator Accuracy C 0,4 Resolution C 0,1 Ext. Probe readings Temp. Read out C Interface Optional (RS232) Heating time 20C/ min.
from Tamb to 200C

0,03 0,03 Audio+Visual 0,15 0,1 / 0,01 opt. (Pt100 & Tc) C/F RS 232 10C/ min. 3C/ min. Standard 150 50 330x340x160 8 500VA optional
Mains cable User manual Support for glass thermometers test cable 500cc silicon oil

Cooling time Switch test Well depth mm Test Wells Dimensions mm Weight Kg Power Carrying case Standard packaging

10C/min.
from 200C to 25C

Standard 125
1 interchangeable

230x220x105 3,5 300VA optional

300x370x140 10 300VA optional

300x370x140 8 800VA optional


Mains cable user manual extraction tools test cable

170x330x450 11 850VA Mains cable user manual extraction tools 4 holes drilled insert: 7 / 9 / 11 / 13,5 mm * Limited at 1000C with 100Vac supply

Mains cable Mains cable 3 holes drilled insert: 3 holes drilled insert: 4.5 / 6.5 / 9.5 mm 4.5 / 6.5 / 9.5 mm extraction tool extraction tool test cable test cable user manual user manual

Custom inserts and blocks diameters are available on request.

Accessories

17mm Metal inserts for T500: cat. EE460016 undrilled cat. EE460017 (1 / 9.5 mm) cat. EE460018 (1 / 8.0 mm) cat. EE460019 (1 / 10.0 mm) cat. EE460020 (1 / 11.0 mm) cat. EE460021 (1 / 12.0 mm)

26mm Metal inserts for T100: cat. EE460010 undrilled cat. EE460011 (1 / 14.5 mm) cat. EE460012 (1 / 17.5 mm) cat. EE460013 (2 / 6.5-12.5 mm) cat. EE460014 (3 / 6.5 mm) cat. EE460015 (3 / 4.5-6.5-9.5 mm)
EUROTRON Instruments S.p.A. V.le F.lli Casiraghi 409/413 I 20099 Sesto S. Giovanni (MI) Tel.: +39-02 248820.1 Fax: +39-02 2440286 e-mail: info@eurotron.com http://www.eurotron.com

26mm Metal inserts for T350: cat. EE460037 undrilled cat. EE460038 (2 / 6.5-12.5 mm)

Distributed by: