Beruflich Dokumente
Kultur Dokumente
W A T L O W
Duct Heaters
Constructed of sturdy 0.430 inch
(11 mm) diameter WATROD heating
elements mounted to a 1⁄4 inch
(6 mm) thick steel flange, duct
heaters are easily adapted to many
non-pressurized, air-heating
systems.
They are easily installed in
applications requiring a wide range
of temperature vs. air flow
combinations.
Watlow duct heaters offer
advantages over gas or oil fired and
open coil electric units with:
• Installation flexibility—
no flues or fuel lines. Threaded
Bussing Hole
• 100 percent energy efficient—
no energy loss up the flue.
• Universal availability of electricity.
Mineral
• Resistance coil in Incoloy® Insulation
sheath is protected from corro-
sive environments. Single
Screw
Clamp
Performance Capabilities
• Watt densities to 40 W/in2
(6.2 W/cm2)
• Recommended process • 31⁄2 inches (90 mm) thick • WATROD hairpins are
temperatures from -20 to 1200°F mineral insulation keeps wiring repressed (recompacted) after
(-7 to 650°C) cooler and reduces heat loss. bending to assure MgO density
• Wattages to 2.2 megawatts • Vented general purpose that eliminates hot spots and
(NEMA 1) terminal enclosure electrical insulation voids.
• Voltages to 600VÅ(ac)
ensures cooler terminations. • Stock heaters feature 6, 12, 18,
Features and Benefits
• A 1⁄4 inch (6 mm) inside 24, 30, 36, 42, 48, 54, and 60
• Long life Incoloy® sheath elements to meet a wide variety
diameter thermowell accepts
Duct Heaters
resists corrosion/oxidation while of kW demands.
an optional Type J or K
protecting resistance coils
thermocouple for accurate • One or three phase voltages to
against contamination.
sheath temperature sensing. meet local power supplies.
• MgO insulation filled elements,
• Rigid stainless steel supports • Maximum 48 amps per circuit
compacted to rock hard density
prevent element sagging or complies with National Electrical
maximize dielectric strength, heat
deformation in various mounting Code (NEC).
transfer and life.
positions. • Duct heaters with general
• Field replaceable heating
• A 1⁄4 inch (6 mm) thick steel purpose enclosures meet UL®
elements permit easy service
flange, with 3⁄8 inch (10 mm) and CSA component recogni-
and reduce downtime. Element
diameter mounting holes, easily tion to 480 and 600VÅ(ac)
change-out is made simple by a
bolts to the duct wall. maximum respectively—UL®
single screw clamp.
and CSA file numbers are
E52951 and 31388.
Incoloy® is a registered trademark of UL® is a registered trademark of
Special Metals Corporation. Underwriter's Laboratories, Inc.
411
1 Duct p411-418 11/22/00 10:55 AM Page 412
Tubular and
Process Assemblies
Duct Heaters
Applications
• Drying ovens • Heat treating
• Autoclaves • Reheating
• Furnaces • HVAC
• Load banks • Paint drying
412
1 Duct p411-418 11/22/00 10:55 AM Page 413
W A T L O W
Tubular and
Process Assemblies
Duct Heaters
Watt Density vs. Air
Temperature/Velocity follow the lines on the graph for sheath temperature of 1400°F
To decide watt density velocity and process temperature to (760°C). For longer heater life,
requirements, first determine the the watt density curve’s intersecting lower watt densities should be
desired outlet air temperature and point. This shows the recommended chosen.
velocity in feet per minute. Then watt density based on a maximum
/in 2
in 2
in 2
/in 2
/in 2
cm 2
cm 2
/cm 2
m2
1500
/cm
/cm
W/
W/
W
W/c
W
8W
W/
W/
1400
5W
W
40
30
20
23
16
6.2
3.1
3.5
2.5
1.25
4.6
1300 400
1200
1100
Air Velocity—MPM
s
s
Air Velocity—FPM
er
er
s
er
er
1000
at
at
300
at
at
He
He
He
He
900
ct
ct
ct
ct
Du
Du
800
Du
Du
g
g
lo
lo
g
lo
700
ta
lo
ta
200
ta
Ca
ta
Ca
Ca
600
Ca
500
400
100
300
200
100
Duct Heaters
10
56
Inlet Temperature at 9
52 Inlet Temperature at
75 Degrees Fahrenheit
25 Degrees Celsius
48 8
44
M M M M 7
FP FP FP
Watt Density—W/cm2
FP
Watt Density—W/in2
40
0 0
50 00 PM PM
PM
PM
15 76 68
12 M M
M
36 6 5 0
23 18
5
5
47
36
32
5
28 PM
0F M
24 30 4 MP
90
20
on
vecti 3 tion
16 l Con vec
rN atura ral Con
12 PM o 2 Natu
60 F PM
or
8 18 M
1
4
0
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 100 200 300 400 500 600 700 800 900 1000
Sheath Temperature—°F Sheath Temperature—°C
413
1 Duct p411-418 11/22/00 10:55 AM Page 414
Tubular and
Process Assemblies
Duct Heaters
Air Flow for ≥ 24kW
Pressure Drop vs. Air Velocity Air flow for
6 to 18kW
The rate at which pressure drops To determine the pressure drop
through the duct heater is critical for through the duct heater, follow the
properly sizing blowers and pumps. air velocity (FPM or MPM) over to
The Pressure Drop vs. Air Velocity the appropriate curve which Thermowell
graph gives recommended identifies the duct heater size. Then, 6kW
maximum velocities in feet per take the intersecting point down to 9kW
minute and meters per minute 12kW
the approximate pressure drop
18kW
according to the air velocity and value. >18kW
duct heater size.
Round and FIREBAR Tubular Duct Heaters Round and FIREBAR Tubular Duct Heaters
Pressure Drop vs. Air Velocity Pressure Drop vs. Air Velocity
2000 800
1900
750 6
1800 12 rD
rD te
1700 a te 700
ea
He tH
1600 ct 650
uc
Du D1
8
2
ar ter rD D1
1500 ul ea 125
600 la ter
D6
b
1400 Tu t H 4-D bu H ea
d uc r D2 550 Tu ct
ater
un rD eate Du D18
1300 o la H nd lar ter
Air Velocity—FPM
Air Velocity—MPM
R u uc t
ub 500
ou bu Hea
t He
dT lar D u ct
1200
un ubu R dT Du 125
nd T 450 un ula
r
24 - D
Duc
R b
900 d Tu
350 Roun
Tub
800
300
nd
700
Rou
250
600
500 200
400 150
300 ® FIREBAR® Duct Heater of Equivalent kW is 30%
FIREBAR Duct Heater of Equivalent kW is 30% 100 ➀
200 the Pressure Drop of a Round Tubular Duct Heater
the Pressure Drop of a Round Tubular Duct Heater ➀ 50
100
0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20 0.005 0.010 0.015 0.020 0.025 0.030 0.035 0.040 0.045 0.050
➀ FIREBAR® flat tubular element duct heaters can be custom designed and built when they enhance your application output or performance.
Although duct heaters are not normally constructed with FIREBAR elements, we show the pressure drop reduction using FIREBAR as a
distinct advantage.
Wattages/Voltages
To meet specific application needs, For more information about this
voltage and wattage combinations option, consult your Watlow
outside stock product parameters representative.
are available.
414
1 Duct p411-418 11/22/00 10:55 AM Page 415
W A T L O W
Tubular and
Process Assemblies
Duct Heaters Terminal Enclosures
In addition to the standard, general
Options • Moisture resistant (NEMA 4)
purpose (NEMA 1) terminal
Continued enclosure, Watlow offers the • Stainless steel corrosion resistant
following optional terminal (NEMA 4X—consult factory)
enclosures to meet specific • Explosion resistant
application requirements: (NEMA 7—consult factory)
• Dust resistant (NEMA 12)
Thermocouples
Type J or K thermocouples, Thermocouples are supplied with variety of temperature and power
inserted in the thermowell, 120 inch (3050 mm) leads (longer controls to meet virtually all
accurately sense element sheath lead lengths available). Unless applications. Temperature controls
temperature for over-temperature otherwise specified, thermocouples can be configured to accept
conditions. are supplied with temperature process variable inputs, too.
To sense process temperature, ranges detailed on the Consult your Watlow representative
sensing element should be located Thermocouple Types chart. for details.
down stream from the duct heater. Using a thermocouple requires an To order a thermocouple, add the
This will eliminate incorrect sensing appropriate temperature and power appropriate suffix letter to the duct
caused by radiant heat. control. These must be purchased heater’s base code number, as
separately. Watlow offers a wide indicated on the Build-a-Code chart
on page 418.
Thermocouple Types
Thermowell
Recommended ➀
ASTM Conductor Characteristics Temperature Range
Type Positive Negative °F (°C)
J Iron Constantan 0 to 1000 (-20 to 540)
(Magnetic) (Non-magnetic)
K Chromel® Alumel® 0 to 2000 (-20 to 1100)
Thermocouple (Non-magnetic) (Magnetic)
➀ Type J and Type K thermocouples are rated 32 to 1382°F and 32 to 2282°F (0-750°C and
Duct heater thermowell holds thermocouple 0-1250°C), respectively. Watlow does not recommend exceeding temperature ranges shown
for sensing sheath temperature. on this chart for the tubular product line.
415
1 Duct p411-418 11/22/00 10:55 AM Page 416
Tubular and
Process Assemblies
Duct Heaters D G
a b C
31/2"
Typical
(89 mm)
Typical
115/8" E
a Stock heaters with six and 12 elements (295 mm)
have one 1 inch NPT conduit opening. 9"
(229 mm)
Stock heaters with 18, 24, 30 and 42
elements have two 1 inch NPT conduit 101/2"
(267 mm)
openings.
Stock heaters with 36, 48, 54 and 60 83/4"
F
elements have two 1 inch NPT and two 31 2"
/
(222 mm)
B
11⁄4 inch NPT conduit openings. 3 8" (89 mm)
/
b
A
All flanges are 12 inches wide. (10 mm)
Diameter 1/4" 77/8" (200 mm)
(6 mm)
Duct Heater Dimensions
Dimension Number of A Dimension B Dimension C Dimension D Dimension E Dimension F Dimension G Dimension
Reference No. Elements in (mm) in (mm) in (mm) in mm) in (mm) in (mm) in (mm)
1 6 27 7⁄8 (708) 20 (508) 2 3⁄4 (70) 6 1⁄2 (165) 3 (76) 5 3
⁄4 (146) 2 1⁄2 (64)
2 12 27 7⁄8 (708) 20 (508) 4 3⁄4 (121) 8 1⁄2 (215) 5 (127) 7 3
⁄4 (197) 3 1⁄2 (89)
3 18 27 7⁄8 (708) 20 (508) 6 3⁄4 (171) 10 1⁄2 (267) 7 (178) 9 3
⁄4 (248) 3 1⁄2 (76)
4 24 27 7⁄8 (708) 20 (508) 8 3⁄4 (222) 12 1⁄2 (318) 9 (229) 11 3
⁄4 (298) 2 3⁄4 (70)
5 30 27 7⁄8 (708) 20 (508) 10 3⁄4 (273) 14 1⁄2 (368) 11 (279) 13 3
⁄4 (349) 3 1⁄4 (83)
6 36 27 7⁄8 (708) 20 (508) 12 3⁄4 (324) 16 1⁄2 (419) 13 (330) 15 3
⁄4 (400) 3 3⁄4 (95)
7 42 27 7⁄8 (708) 20 (508) 14 3⁄4 (375) 18 1⁄2 (470) 15 (381) 17 3
⁄4 (451) 4 1⁄4 (108)
8 48 27 7⁄8 (708) 20 (508) 16 3⁄4 (425) 20 1⁄2 (521) 17 (432) 19 3
⁄4 (502) 4 3⁄4 (121)
9 54 27 7⁄8 (708) 20 (508) 18 3⁄4 (476) 22 1⁄2 (572) 19 (483) 21 3
⁄4 (552) 5 1⁄4 (133)
10 60 27 7⁄8 (708) 20 (508) 20 3⁄4 (527) 24 1⁄2 (622) 21 (533) 23 3
⁄4 (603) 5 3⁄4 (146)
11 60 32 7⁄8 (835) 25 (635) 20 3⁄4 (527) 24 1⁄2 (622) 21 (533) 23 3⁄4 (603) 5 3⁄4 (146)
12 60 40 3⁄8 (1026) 32 1⁄2 (826) 20 3⁄4 (527) 24 1⁄2 (622) 21 (533) 23 3⁄4 (603) 5 3⁄4 (146)
13 60 49 3⁄8 (1254) 41 1⁄2 (1054) 20 3⁄4 (527) 24 1⁄2 (622) 21 (533) 23 3⁄4 (603) 5 3⁄4 (146)
416
1 Duct p411-418 11/22/00 10:55 AM Page 417
W A T L O W
Tubular and
Process Assemblies
Duct Heaters
30 W/in2 (4.7 W/cm2)
Dimension Number Code No. Est. Ship.
kW Reference of 240VÅ(ac) # of 240VÅ(ac) # of 480VÅ(ac) # of 480VÅ(ac) # of Weight
No. Elements 1-Phase Circ. 3-Phase Circ. 1-Phase Circ. 3-Phase Circ. lbs (kg)
9 1 6 D6SX10 1 D6SX3 1 D6SX11 1 D6SX5 1 50 (23)
18 2 12 D12SX10 2 D12SX3 1 D12SX11 1 D12SX5 1 55 (25)
27 3 18 D18SX10 3 D18SX3 2 D18SX11 2 D18SX5 1 65 (30)
36 4 24 D24SX10 4 D24SX3 2 D24SX11 2 D24SX5 1 95 (43)
45 5 30 D30SX3 5 D30SX11 2 D30SX5 2 120 (55)
54 6 36 D36SX3 3 D36SX11 3 D36SX5 2 135 (62)
63 7 42 D42SX3 7 D42SX11 3 D42SX5 2 155 (71)
72 8 48 D48SX3 4 D48SX11 4 D48SX5 2 195 (89)
81 9 54 D54SX3 6 D54SX11 6 D54SX5 3 205 (93)
90 10 60 D60SX3 5 D60SX11 4 D60SX5 4 235 (107)
115 11 60 D75SX3➁ 10 D75SX11 5 D75SX5 4 260 (118)
150 12 60 D100SX5➁ 4 290 (132)
190 13 60 D125SX5➁ 5 310 (141)
Replacement Elements
Replacement Elements Original Replacement A Replacement Availability Est. Net
Replaceable heating elements Duct Heater Element Dimension Element Weight
provide easy field service and Code Numbers Volts Watts in (mm) Code No. lbs (kg)
reduce downtime. Element 20 W/in2 (3.1 W/cm2)
change-out is made simple by a D6S3 to D60S3 240 1000 277⁄8 (708) D6240 Stock 1.0 (0.5)
single screw clamp. D6S5 to D60S5 480 1000 277⁄8 (708) D6480 Stock 1.0 (0.5)
To order replacement elements, D75S3 240 1250 327⁄8 (835) D75240 Standard 1.0 (0.5)
specify the replacement element D75S5 480 1250 32 7⁄8 (835) D75480 Stock 1.0 (0.5)
code number (from the table) that D100S5 480 1667 40 3⁄8 (1026) D100480 Stock 1.4 (0.7)
corresponds to the original Watlow D125S5 480 2083 49 3⁄8 (1254) D125480 Stock 1.7 (0.8)
duct heater code number. Then 30 W/in2 (4.7 W/cm2)
specify quantity. D6SX3 to D60SX3 240 1500 277⁄8 (708) D6X240 Stock 1.0 (0.5)
D6SX5 to D60SX5 480 1500 27 7⁄8 (708) D6X480 Stock 1.0 (0.5)
D75SX3 240 1917 32 7⁄8 (835) D75X240 Standard 1.0 (0.5)
Duct Heaters
D75SX5 480 1917 32 7⁄8 (835) D75X480 Stock 1.0 (0.5)
D100SX5 480 2500 40 3⁄8 (1026) D100X480 Stock 1.4 (0.7)
D125SX5 480 3167 49 3⁄8 (1254) D125X480 Stock 1.7 (0.8)
417
1 Duct p411-418 11/22/00 10:55 AM Page 418
Tubular and
Process Assemblies F.O.B.: Hannibal, Missouri
Duct Heaters
Build-a-Code
- -
Thermocouple Sensor
J = Type J
K = Type K
418
2 Modular Duct p419-426 11/22/00 1:32 PM Page 419
W A T L O W
Tubular and
Process Assemblies
Modular Duct Heater
Watlow has developed a new line of
process air heaters that offer
improved performance and
increased versatility in medium to
low temperature applications.
The new duct heaters are modular
and consist of two parts. The first is
a 6kW heater available in either
240 or 480 volts, single or three
phase.
The second part of the heater
consists of the electrical housing that
protects each module’s termination
area and a main flange that bolts
into the user’s ductwork. The heater
modules are installed in the housing
and main flange via rectangular slots
in the main flange. The range of
modules that can be accommodated
in various duct heater assemblies,
range from 1-10 modules. A range
of 6-60kW, in 6kW increments is
achieved. Features and Benefits Applications
The new design of the modular duct • Individual modules removable • Low temperature ovens
heater offers increased reliability. through housing reduces • Parts drying
The individual modules are downtime for replacement of
• Semiconductor clean room
removable through the housing of module.
environmental heating
the assembly, which eliminates the • 27 percent reduction in heat-up
need to pull the complete heater • Plastic curing
time as compared to traditional
from the ductwork. This reduces 0.430 inch diameter duct heater • Load banks
downtime and costs because the elements result in a faster • Heated air knives
heating elements can be replaced response time. • Food dehydration
individually.
• Smaller diameter elements • Heat shrink tunnels
Performance improvements include (0.315 inch) result in a 25
Duct Heaters
quicker response time and reduced percent lower energy usage on
infiltration from the air stream being initial heat-up.
heated into the electrical enclosure. • 31 percent lighter weight than
traditional tubular duct heaters
reduces shipping costs and
increases worker safety.
• Greater free cross sectional
area results in lower pressure
drop.
• Improved seal between element
and electrical housing results in
lower electrical housing
temperature.
• Flexible module wiring allows
user to sequentially stage
modules.
419
2 Modular Duct p419-426 11/22/00 1:32 PM Page 420
Tubular and
Process Assemblies
Modular Duct Heater
Velocity vs. Process Temperature
1100
Velocity – Feet/Min
1000 8 WSI
900
800
700
600
500
400
300
200
100
0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
40
300 FPM
Watt Density-W/in2
30
60 FPM
20 Natural
Convection
10
0
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400
420
2 Modular Duct p419-426 11/22/00 1:32 PM Page 421
W A T L O W
Tubular and
Process Assemblies
Modular Duct Heater
D A
Typ.
31/2"
Typ.
B
115/8"
8"
101/2"
C
213/4"
12" 1 4"
/
261/16" 3/8"
Diameter
Duct Heaters
26 36 480 1 2 6 95 Assy. Stk. MDH36S11 18.00 13.75 17.25 4.13
26 36 480 3 1 6 95 Assy. Stk. MDH36S5 18.00 13.75 17.25 4.13
26 42 240 3 3 7 109 Assy. Stk. MDH42S3 20.25 16.00 19.50 4.69
26 42 480 1 3 7 109 Assy. Stk. MDH42S11 20.25 16.00 19.50 4.69
26 42 480 3 2 7 109 Assy. Stk MDH42S5 20.25 16.00 19.50 4.69
26 48 240 3 4 8 137 Assy. Stk. MDH48S3 22.50 18.25 21.75 5.25
26 48 480 1 3 8 137 Assy. Stk. MDH48S11 22.50 18.25 21.75 5.25
26 48 480 3 2 8 137 Assy. Stk. MDH48S5 22.50 18.25 21.75 5.25
26 54 240 3 3 9 144 Assy. Stk. MDH54S3 24.75 20.50 24.00 5.81
26 54 480 1 3 9 144 Assy. Stk. MDH54S11 24.75 20.50 24.00 5.81
26 54 480 3 2 9 144 Assy. Stk. MDH54S5 24.75 20.50 24.00 5.81
26 60 240 3 4 10 165 Assy. Stk. MDH60S3 27.00 22.75 26.25 6.38
26 60 480 1 4 10 165 Assy. Stk. MDH6OS11 27.00 22.75 26.25 6.38
26 60 480 3 2 10 165 Assy. Stk. MDH60S5 27.00 22.75 26.25 6.38
Options include individual modules with optional NEMA1 housing, high temperature thermocouple kit and blank flange modules.
Modular duct heaters with 1 and 2 modules have conduit openings for 1-1 inch NPT fitting.
Modular duct heaters with 3,4,5, and 7 modules have conduit openings for 2-1 inch NPT fittings.
Modular duct heaters with 6,8,9, and 10 modules have conduit openings for 2-1 1⁄4 inch NPT and 2-1 inch NPT fittings.
421
2 Modular Duct p419-426 11/22/00 1:32 PM Page 422
Tubular and
Process Assemblies
Modular Duct Heater
Individual Module Dimensions
21/4"
Specifications
TOP
PN XXXXXXXXX
Incoloy® elements
• High-limit thermocouple installed
by drilling premarked hole in 22"
flange
• 6-60kW range when mounted in
duct heater assembly
Options
Application Information Terminal Enclosures Blank Module Covers
• Maximum sheath temperature Module covers are available for
Terminal enclosures are available in
= 1200˚F covering blank slots on the main
NEMA 1 and 4 configurations.
• Maximum outlet temperature flange. This allows for adding heater
High-Limit Thermocouples
= 750˚F module at a later time to allow higher
High-limit thermocouples can be
wattage outputs.
supplied on specified modules or
shipped as a kit. Available
thermocouples are Types J and K.
Watlow
Code Number Description
Replacement Modules
M63 6kW, 240 volts, 3 phase
M610 6kW, 240 volts, 1 phase
M65 6kW, 480 volts, 3 phase
M611 6kW, 480 volts, 1 phase
High Limit Thermocouple Kits
MTCJ Type J (0-1000°F)
MTCK Type K (0-2000°F)
Blank Module Covers
MBLK Cover slots in main flange
Availability
• Assembly Stock: Three to five
working days
• Made-to-Order: Eight weeks
Consult factory for more details.
422