Sie sind auf Seite 1von 2

Coherent

Solid-State

Ultrafast

MIRA900
Modelocked Ti:Sapphire Lasers

Mira Optima 900-F


System Specifications1 Output Power2,3 (Verdi- V5 pump) (Verdi-V8) (Verdi-V10) (Innova 310 8 W) Sabre 14 W Tuning Range4 (700 to 1000 nm typical) Autocorrelation5 Repetition Rate Noise6 Stability7 Beam Diameter8 Beam Divergence9 Spatial Mode10 Polarization Physical Dimensions
1 Specifications apply only with Coherent

Mira Optima 900-P

Mira Optima 900-D

Mira 900-S

0.65 W 1.0 W 1.3 W 0.8 W 1.4 W 700 to 980 nm <200 fs

0.65 W 1.0 W 1.3 W 0.8 W 1.4 W 700 to 980 nm <3 ps

0.65 W 1.0 W 1.3 W 0.8 W 1.4 W 700 to 980 nm <3 ps and <200 fs 76 MHz, nominal <0.1% (Verdi) <2% (Sabre/Innova) <3% (Verdi) <5% (Sabre/Innova) 0.8 mm 1.7 mrad TEM00 Horizontal

0.65 W 1.0 W 1.3 W 0. 8 W 1. 4 W 700 to 980 nm <200 fs

111.1 x 38.1 x 19.7 cm (43.75 x 15 x 7.75 in.)

pump lasers. 2 At 800 nm. 3 For Verdi-V6, call factory. 4 Wider coverage possible with short wave or extended long wave optics sets. 5 Multiply by 0.65 sech2 deconvolution factor for pulse duration. 6 Measured rms in a 10 Hz to 20 MHz bandwidth. 7 Power drift in any two-hour period after warm-up when crystals cooling water is maintained at 0.1C. 8 1/e2 diameter (0.2 mm) at exit port. 9 Full angle divergence (0.3 mrad) at exit port. 10 Typical measured M2 value is 1.1
2.0
10W Verdi pump 8W Verdi pump 5W Verdi pump

1.8 1.6
10W Verdi pump 8W Verdi pump 5W Verdi pump

Output Power (W)

Output Power (W)


700

1.6

1.4 1.2 1.0 0.8 0.6 0.4 0.2

1.2

0.8

0.4

0.0

750

800

850

900

950

1000

0.0

700

750

800

850

900

950

1000

Wavelength (nm)

Wavelength (nm)

Typical X-Wave Power Tuning Curves for Verdi-pumped Mira Optima 900-F

Typical X-Wave Power Tuning Curves for Verdi-pumped Mira Optima 900-P

MIRA900
Mira Optima 900-P
M8 M10 M9 M8 GTI M7

Modelocked Ti:Sapphire Lasers

Mira Optima 900-F / Mira 900-S


M9

P1 L M4

PUMP LASER

M4

Ti:Al2O3
SLIT M5 M1 OC

PUMP LASER
P2 M6

Ti:Al2O3
SLIT M5 M1 OC M3

M2

BRF M3

M2

BRF

Mira Optima 900-D


M8 M10 M9

GTI M7 P1 L M4

PUMP LASER
P2 M6

Ti:Al2O3
SLIT M5 M1 OC M3

M2

BRF

Laser Head - Top View


111.13 (43.75) ALTERNATE INPUT

OUTPUT 38.1 (15.00) 15.04 (5.92) 87.74 (34.15)

30.07 (11.84) INPUT 4.01 (1.58) ALTERNATE INPUT

7.95 (3.13)

Laser Head - Front View


12.85 (5.06) 19.69 (7.75) 12.07 (4.75) 15.04 (5.92) 30.84 (11.84) 25.25 (9.94) 18.75 (7.38) 1.91 (0.75) 4.01 (1.58)

Laser Head - Rear View Laser Head - Side View


11.13 (4.38) 26.97 (10.62)

12.07 (4.75)

Dimensions are in cm (inches)

C O H E R E N T, I N C . Coherent follows a policy of continuous product improvement.


5100 Patrick Henry Drive Santa Clara, CA 95054 Phone: 1-800-527-3786 1-408-764-4983 Fax: 1-800-362-1170 1-408-988-6838 Email: tech.sales@CoherentInc.com Web: www.CoherentInc.com
LO C A L O F F I C E S

Specifications are subject to change without notice. Coherents scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976. Coherent offers a limited warranty for all Mira systems. For full details on warranty coverage, please refer to the Service and Support section at www.CoherentInc.com, or contact your local Sales or Service Representative.

Japan France Italy UK

+81 (3) 5635 8700 +33 (1) 6985 5145 +39 (02) 34 530 214 +44 (1353) 658 800

Benelux +31 (30) 280 6060 Germany +49 (6071) 9680

VISIBLE AND INVISIBLE LASER RADIATION. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION. CLASS 4 LASER PRODUCT PER EN60825-1 (1994) MAXIMUM OUTPUT IS DEPENDENT UPON AND LESS THAN INPUT RADIATION EMITTED. WAVELENGTH IS VARIABLE FROM 250 nm to 1400 nm.

Printed in the U.S.A. MC-135-02-5C0902 Copyright 2002 Coherent, Inc.

93/42/EEC 0459