FIREX-II TECK CABLE

Introduction

Index
FIREX-II TECK Cable

Applications

Design Features

Construction Data

Nexans FIREX-II TECK Cables are intended for use in various primary and
secondary industries, including chemical processing plants, refineries and general
factory environments. Even in the most demanding industrial and resource industry
applications, Nexans FIREX-II TECK Cables have proven to have a superior
service and maintenance record.

FIREX-II TECK Cable


Specifications

Multiconductor 600 V

FIREX-II TECK Cables utilize low acid gas, low flame spread PVC jacket
compounds to ensure maximum safety to personnel and equipment in the event of
fire.

Composite Power &


Control 600 V

10

1000 V

11

5 kV (unshielded & shielded)

15

8 kV (100% & 133%)

19

15 kV (100% & 133%)

23

For more than 85 years, Nexans has been a leading designer and manufacturer of
electrical cables for a wide variety of applications.
As a technology leader, Nexans has an experienced team of engineering,
manufacturing and sales professionals to ensure that high standards of design,
quality and service are maintained throughout the entire manufacturing process
from ordering to delivery.

More than 50 standard power and control constructions are available from stock,
while custom-designed sizes and types can be quoted on request. Our
computerized order processing system, in conjunction with up-to-date inventories
and our knowledgeable sales staff, ensures complete customer satisfaction.

Installation and
Technical Data

2738

Stranded Bare Copper


and Aluminum Conductor
Information

39

Metric Conversion
Tables

40

Firex, Exelene and Exelcure are registered trademarks of Nexans Canada Inc.

Applications

FIREX-II TECK Cables, originally


developed for use in Canadian
mines, are flexible, resistant to
mechanical abuse, corrosion
resistant, compact and reliable. They
are suitable for a wide range of
applications, including ALL
hazardous locations.
Industries such as pulp and paper,
chemical, petroleum and other
primary and secondary
manufacturing industries have used
FIREX-II TECK Cables, particularly in
areas where cables are subject to the
risk of mechanical damage and
chemical attack.
Commercial applications for FIREX-II
TECK Cables include apartment
buildings and commercial complexes.
FIREX-II TECK Cables can be
relocated easily because they are
rugged and flexible. They can be
used in both dry and wet locations in
open wiring, in ventilated, nonventilated and ladder-type cable
troughs, in ventilated flexible
cableways, and for direct burial.
TECK Cables are also suitable for
service entrance installations above
and below ground.

Highlights
Nexans FIREX-II TECK Cables
are

Available from stock


Versatile
Flexible
Resistant to Mechanical Abuse
and Corrosion
Compact and Reliable
HL and FT4 Rated
90C to 40C
Low Acid Gas (AG14)

Design Features
FIREX-II TECK CABLE

Standards Certification

Nexans, recognizing a need to


develop cable products which
minimize the effects of accidental fire,
manufacture Teck cable with jacket
compounds that assist in the limitation
of fire spread and acid gas evolution.

Nexans FIREX-II TECK 90 Minus 40C


Cables are certified to CSA Standard
C22.2 No. 131M89 (R1999) Type
TECK 90 Cables, up to 5 kV, shielded
and non shielded. File No. 23462.

When subjected to the Vertical Flame


Test Cables in Cabletroughs,
described in paragraph 4.11.4 of
CSA Standard C22.2 No. 0.301 the
complete cables, with or without outer
jacket, meet the 1.5 metre flamespread limit for cable damage. As a
result, Nexans Teck Cables are
marked with an FT4 designation.
The inner jackets of FIREX-II Cables
are flame-retardant in accordance
with Clause 4.11.1 of CSA Standard
C22.2 No. 0.301 and both inner
and outer jackets meet the acid gas
evolution requirement of 14%
maximum when tested to clause 4.31
of CSA Standard C22.2 No. 0.301.
As a result, Nexans Teck Cables are
marked with an AG14 designation.
This significant reduction in the
amount of corrosive acidic gases
evolved under fire conditions ensures
added safety to operational personnel
and protection of sensitive electronic
equipment.
In addition to meeting the CSA FT4
requirements at 70,000 BTU/hr,
Nexans FIREX-II TECK Cables pass
the ICEA T29-520 Vertical Cable Tray
Flame Test using a 210,000 BTU/hr
flame.
They also pass the IEEE Standard 383
Vertical Flame Test on grouped
cables.

Nexans FIREX-II TECK armoured


power cables, 8 kV shielded and
higher, are certified to CSA C68.397
(R2001) Shielded and Concentric
Neutral Power Cables Rated 546
kV, Power Cable with Thermoset
Insulation. File No. 26291.
Nexans multiconductor FIREX-II TECK
90 Minus 40C Cables with more than
four conductors are certified to CSA
Standard C22.2 No. 23997 (R2001)
Control and Instrumentation Cables.
File No. 26831.
All FIREX-II TECK Cable constructions
are certified to CSA C22.2 No. 174M1984 (R1999), File No. 19376 for
use in the following Hazardous
Locations:
Class I Groups A, B, C, D.
Divisions 1 and 2
Class II Groups E, F, G.
Divisions 1 and 2
Class III

Caution Notice

All Nexans FIREX-II TECK Cable


constructions up to 46 kV are marked
HL and can be used in any of the
hazardous locations listed.

In case of fire, well maintained early


warning smoke detectors will give an
alarm long before non-metallic
coverings become combustible.

For terminations and splices in


hazardous locations, approved
hazardous connectors must be
employed. (Approved non-hazardous
connectors are shown on the Cable
Specifications Tables.)
FIREX-II TECK 90 Minus 40C Cable
with steel armour has been approved
for use in the gaseous mines category
of the provisions of CSA Standard
C22.2 No. 174-M1984 (R1999).
(Certificate No. 596 Feb. 5, 1985,
Research and Technology Division of
Energy, Mines and Resources
Canada.)

However, in spite of the widespread


and long-standing use of PVC in
residential and commercial buildings,
all purchasers of PVC insulated/
jacketed products should be aware of
the following:
Non-metallic coverings of electrical
cables can burn and may transmit
fire when ignited.
Burning non-metallic coverings may
emit acid gases which are toxic and
may generate dense smoke.
Emission of acid gases may corrode
metal in the vicinity; e.g. sensitive
instruments and reinforcing rods in
cement.

Construction Data
Conductors
ASTM Class B stranded soft bare
copper. In sizes 8 AWG to 1000
kcmil, the conductors are compact
stranded to reduce cable diameter and
weight. Aluminum conductors can be
provided on special request.

Conductor Shield
Extruded semiconducting cross-linked
polyethylene conductor shielding is
applied to cables rated over 1000 V.

Insulation
EXELENE Insulation is used in Nexans
FIREX-II TECK Cables. EXELENE is
the Nexans trademark for cross-linked
polyethylene, the most widely used
polymeric material for insulating both
low and high voltage cables. The
insulated conductors in the unshielded
TECK cables rated 5 kV or less meet
the requirement of CSA for RW90
XLPE. Shielded FIREX-II TECK
armoured power cables rated 5 kV or
higher are insulated with tree-retardant
unfilled EXELENE meeting the
requirements of CSA Standard
C68.3-97 (R2001).
Designs are also available employing
AEIC-CS8-2000 insulated conductors
5 kV shielded and above.

Insulation Shield
Shielded FIREX-II TECK Power cables
rated 5 kV and higher have an
extruded layer of strippable semiconducting insulation shielding material,
applied using the EXELCURE process.
In multiconductor cables, the metallic
shield is copper tape, while in the
single conductor cables the concentric
ground provides the metallic shield.
Specific designs of metallic shielding
can be provided where required to
meet special conditions.
For shielded cable, Nexans has
introduced EXELCURE, its state of the
art process of dry curing insulation

systems. A reduction in moisture levels


during the curing process will reduce
the size and the number of voids in the
cable insulation resulting in longer
electrical life.
Radiant heat from the electrically
heated tube cures the polymer in a
pressurized dry nitrogen atmosphere.
Curing temperatures are in the
neighbourhood of 200300 degrees
Celsius at a pressure of ten
atmospheres. A scanning laser beam
monitors and controls the diameter of
the cable to preset conditions.
Detailed operating parameters are
maintained by a programmable microprocessor and display panel which
controls all heats, curing tube
temperature profile, pressures, cooling
levels and nitrogen pressurization
sequence.

Equipment Bonding
Conductor

Armour
Interlocking aluminum tape armour is
applied directly over the inner jacket.
Galvanized steel is also available on
request, but only for multiconductor
cables.

Outer Jacket
Low-acid-gas-emitting(b) fire-retardant(c)
PVC rated for low temperature is used.
See adjacent table for the physical
properties of this jacket material. The
standard outer jacket colour is black
for 600 V and 1 kV; orange for 5 kV;
and red for 15 kV. Other outer jacket
colours are available on special
request.
(a) Flame retardant means that a
cable with this material will pass the
FT1 Flame Test, Clause 4.11.1 of
CSA Standard C22.2 No. 0.301,
Test Methods for Electrical Wires and
Cables.

Class B stranded soft bare copper is


the standard equipment bonding
conductor material. Sizes are in
accordance with Table 16 of the
Canadian Electrical Code, Part 1. In
single conductor cables the equipment
bonding conductor is in the form of
concentric wires over the insulation or
shield. In three conductor cables with
metallic shielding the equipment
bonding conductor is in contact with
the shields.

(b) Low acid gas emitting means that


this material will not exceed the low
acid gas evolution limit of 14% when
tested in accordance with CSA
Standard C22.2 No. 0.301. Cables
are identified with the designation
AG14.

Fillers

Marking and
Identification

Where fillers are required, nonhygroscopic materials are used.

Core Binder
Where required, a binder tape is
applied over the assembled core.

Inner Jacket
The black PVC jacket is 90C and low
temperature rated, flame retardant(a),
and low acid gas emitting(b). See
adjacent table for physical properties
of this jacket material.

(c) Fire retardant means that a cable


with this material will pass the FT4
requirements of CSA Standard C22.2
No. 0.301 (Clause 4.11.4).

The outer jackets of Nexans FIREX-II


TECK Cables up to 5 kV are printed
TECK 90 XLPE HL FT4 AG14 (40C)
FIREX-II, and with conductor size and
voltage rating. Cables rated above 5
kV are designated as POWER CABLE
in accordance with CSA C68.3.

Construction Data
Identification of Conductors
No. of Conductors

Identification Key

1
2
3
4
5 or more
Composite
power
control

none
black, white
red, black, blue
red, black, blue, white
number coding
colour coding
number coding

Size
14-2
1-1000

Identification Method
Colours
Numbers
coloured insulation
coloured stripes

printed
printed

* Other methods and colour codes are available on request.

EXELENE Properties

Physical

Tensile Strength (MPa)


Elongation (%)
After 7 days at 121C in air oven:
Residual Tensile Strength (%)
Residual Elongation (%)
Electrical
Power Factor (%)
Dielectric Constant

CSA
Requirements
C22.2 No. 131
(up to 5 kV)

CSA
Requirements
C68.3
(above 5 kV)

12.4 min.
150 min.

12.4 min.
250 min.

75 min.
75 min.

75 min.
75 min.

*
6.0 max.

2.0 max.
3.5 max.

Environmental

Moisture Absorption:
After 7 days at 70C (mg/in2)

5.0 max.

PVC Properties
Physical

Tensile Strength MPa)


Elongation (%)
After 14 days at 121C in air oven:
Residual Tensile Strength (%)
Residual Elongation (%)
After 7 days at 100C in air oven:
Residual Tensile Strength (%)
Residual Elongation (%)
After 4 hours in oil at 70C:
Residual Tensile Strength (%)
Residual Elongation (%)

Inner
Jacket

CSA Requirements
Outer
Jacket

10.35 min.
100 min.
75 min.
65 min.
*
*

12.4 min.
200 min.
*
*
85 min.
60 min.

75 min.
75 min.

75 min.
75 min.

no cracks
no cracks

no cracks
no cracks

Environmental

Cold bend test at 40C


Cold impact test at 40C
*Not applicable

FIREX-II TECK Cable Specifications


The tables in this catalogue give
essential data for FIREX-II TECK
90 Minus 40C and FIREX-II
TECK armoured power cables.
The following should be borne
in mind when using these
tables:
Dimensions and weights are
approximate and subject to
manufacturing tolerances. Weights
shown are for cable only; add 20% to
obtain estimated shipping weight.
100% Insulation Level may be used in
systems where faults will clear within
one minute. Such systems may be
grounded or ungrounded. 133%

Insulation Level is recommended


wherever fault clearing times may
exceed one minute but not one hour,
and where additional insulation
strength is desired. For other cases,
including resonant grounded systems
and where fault clearing time may
exceed one hour, 173% Insulation
Level is recommmended.
Ampacities based on Rule 4-004 and
Table 1 and 2 of CSA C22-1 2002
(Canadian Electrical Code) apply to
cables with copper conductors rated
up to and including 5000 V. Single
conductor cables may require
derating in accordance with CEC Rule
4-008.

For cables rated over 5000 V,


ampacities are based on ICEA
Publication P-46-426. Inspection
authority agreement is required to use
these values. The equipment bonding
conductor sizes shown are specified in
CSA C68.3-97 (R2001) and are based
on the requirements of Table 16 and
on the ampacities of Table 2 of the CE
Code. These cables may also be used
for lower voltage cables in
accordance with CEC, Appendix B
note on Rule 4-004.
As noted in Appendix B (notes on
Rule 4-004) of the Canadian Electrical
Code, ampacities other than those
shown in Tables 1 and 2 may also be
used for cables rated up to 5000 V.
This note, as well as tables in
Appendix D, give ampacities of
cables direct buried or in
underground raceway (duct).
Cable fitting data is based on
information published by the relevant
manufacturers for non-hazardous
locations. CSA certified fittings of
manufacturers other than those shown
may also be used. When ordering
fittings, it is recommended that the
cable dimensions be provided to the
fitting supplier to ensure proper fit. In
some instances the fittings shown may
require the removal of the inner
jacket.
Enquiries are invited for cables of
other sizes and voltage ratings to
comply with special requirements.
Information on fittings for hazardous
locations is available from Nexans
and fittings manufacturers.

Multiconductor TECK 90 (XLPE) Minus 40C

14 AWG 600 V

No. 14 AWG Bonding Conductor


Number
of
Conductors

Ampacity 15 A*
Approximate Diameters

inches

mm

inches

mm

2
3
4

0.030
0.030
0.030

0.76
0.76
0.76

0.045
0.045
0.045

1.14
1.14
1.14

0.369
0.390
0.444

9.37
9.91
11.27

0.600
0.621
0.676

15.24
15.77
17.17

0.688
0.709
0.761

17.48
18.01
19.33

191
225
266

284
335
396

57
77
96

5
6
7

0.030
0.030
0.030

0.76
0.76
0.76

0.045
0.045
0.045

1.14
1.14
1.14

0.472
0.515
0.522

11.99
13.08
13.26

0.703
0.743
0.755

17.86
18.87
19.18

0.787
0.828
0.844

19.99
21.03
21.44

306
316
338

455
471
502

115
134
154

8
9
10

0.030
0.030
0.030

0.76
0.76
0.76

0.060
0.060
0.060

1.52
1.52
1.52

0.597
0.608
0.671

15.16
15.45
17.04

0.825
0.836
0.898

20.96
21.23
22.81

0.909
0.923
0.984

23.09
23.44
24.99

384
409
448

571
609
667

173
192
212

11
12
15
19

0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.060
0.060
0.060
0.060

1.52
1.52
1.52
1.52

0.679
0.700
0.750
0.835

17.25
17.78
19.05
21.21

0.906
0.927
0.990
1.073

23.01
23.55
25.15
27.25

0.992
1.013
1.090
1.157

25.18
25.73
27.69
29.39

466
489
583
748

693
728
868
1113

231
250
308
385

20
25
30
35

0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.060
0.080
0.080
0.080

1.52
2.03
2.03
2.03

0.850
0.983
1.060
1.152

21.59
24.99
26.92
29.26

1.105
1.239
1.311
1.372

28.07
31.47
33.30
34.85

1.189
1.326
1.399
1.488

30.20
33.68
35.53
37.80

766
852
995
1066

1140
1268
1481
1587

404
501
597
693

40
50
60
80
90

0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76

0.080
0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03
2.03

1.179
1.282
1.435
1.604
1.689

29.95
32.56
36.45
40.74
42.90

1.431
1.535
1.710
1.954
2.039

36.35
38.99
43.43
49.63
51.79

1.519
1.642
1.850
2.094
2.183

38.86
41.71
46.99
53.18
55.44

1224
1468
1613
2132
2347

1822
2184
2400
3173
3494

790
982
1175
1561
1753

Armour

Outer
Covering
inches
mm

Copper
Content

Inner Jacket
Thickness
inches
mm

Number
of
Conductors

Inner
Jacket

Approximate Weight
Aluminum
Armour
lb/kft
kg/km

Insulation
Thickness
inches
mm

kg/km

Fittings
Appleton

T&B

Commander

CrouseHinds

2
3
4

TMC 6550
TMC 6550
TMC 8875

10464/ST050-464
10464/ST050-464
10465/ST050-465

TCA-50-078
TCA-50-078
TCA-50-078

ST050-464
ST050-464
ST050-465

5
6
7

TMC 8875
TMC 8875
TMC 8875

10465/ST050-465
10465/ST050-465
10465/ST050-465

TCA-50-089
TCM-50-089
TCM-50-089

ST050-465
ST050-465
ST050-465

8
9
10

TMC 8875
TMC 8875
TMC 118100

10466/ST050-466
10467/ST075-467
10467/ST075-467

TCM-50-098
TCM-75-106
TCM-75-106

ST050-466
ST075-467
ST075-467

11
12
15
19

TMC 118100
TMC 118100
TMC 118100
TMC 118100

10467/ST075-467
10467/ST075-467
10468/ST075-468
10468/ST075-468

TCM-75-106
TCM-75-106
TCM-75-118
TCM-100-135

ST075-467
ST075-467
ST075-468
ST075-468

20
25
30
35

TMC 118100
TMC 140125
TMC 140125
TMC 166150

10469/ST100-469
10469/ST100-469
10470/ST125-470
10470/ST125-470

TCM-100-135
TCM-125-151
TCM-125-151
TCM-125-151

ST100-469
ST100-469
ST125-470
ST125-470

40
50
60
80
90

TMC 166150
TMC 166150
TMC 206200
TMC 206200
TMC 206200

10550/ST125-550
10471/ST125-471
10472/ST150-472
10551/ST200-551
10474/ST200-473

TCM-125-167
TCM-125-167
TCM-150-192
TCM-200-231
TCM-200-231

ST125-550
ST125-471
ST150-472
ST200-551
ST200-473

* Canadian Electrical Code Table 5C


will apply if cable is used for power
applications or the conductors are
continuously loaded.

Multiconductor TECK 90 (XLPE) Minus 40C

12 AWG 600 V

No. 14 AWG Bonding Conductor


Number
of
Conductors

Ampacity 20 A*
Approximate Diameters

inches

mm

inches

mm

2
3
4

0.030
0.030
0.030

0.76
0.76
0.76

0.045
0.045
0.045

1.14
1.14
1.14

0.405
0.429
0.502

10.29
10.90
12.75

0.636
0.660
0.733

16.15
16.76
18.62

0.724
0.745
0.817

18.39
18.92
20.75

238
280
298

354
417
443

80
111
141

5
6
7

0.030
0.030
0.030

0.76
0.76
0.76

0.045
0.060
0.060

1.14
1.52
1.52

0.522
0.599
0.614

13.26
15.21
15.60

0.752
0.828
0.843

19.10
21.03
21.41

0.839
0.912
0.927

21.31
23.16
23.55

347
402
438

516
598
652

172
203
233

8
9
10

0.030
0.030
0.030

0.76
0.76
0.76

0.060
0.060
0.060

1.52
1.52
1.52

0.656
0.700
0.744

16.66
17.78
18.90

0.884
0.940
0.988

22.45
23.87
25.10

0.970
1.014
1.077

24.66
25.76
27.35

476
496
531

708
738
790

264
295
325

11
12
15
19

0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.060
0.060
0.060
0.080

1.52
1.52
1.52
2.03

0.760
0.776
0.842
0.905

19.30
19.71
21.39
22.99

1.028
1.037
1.101
1.160

26.11
26.34
27.97
29.46

1.096
1.125
1.189
1.233

27.84
28.57
30.20
31.32

622
651
755
937

925
969
1123
1394

356
387
478
601

20
25
30
37

0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

0.974
1.093
1.167
1.308

24.74
27.76
29.64
33.22

1.233
1.348
1.421
1.583

31.32
34.24
36.09
40.20

1.321
1.436
1.509
1.678

33.55
36.47
38.32
42.62

973
1165
1302
1495

1448
1733
1938
2224

632
785
938
1153

40
50
60
80
90

0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76

0.080
0.080
0.080
0.110
0.110

2.03
2.03
2.03
2.79
2.79

1.367
1.483
1.615
1.865
1.962

34.72
37.67
41.03
47.37
49.85

1.642
1.758
1.965
2.215
2.312

41.71
44.65
49.91
56.26
58.72

1.737
1.853
2.015
2.269
2.366

44.12
47.06
51.18
57.63
60.09

1593
1884
2311
3021
3318

2370
2804
3439
4495
4937

1245
1551
1857
2470
2777

Armour

kg/km

Fittings
Appleton

T&B

Commander

CrouseHinds

2
3
4

TMC 6550
TMC 8875
TMC 8875

10464/ST050-464
10464/ST050-464
10465/ST050-465

TCA-50-078
TCA-50-078
TCA-50-089

ST050-464
ST050-464
ST050-465

5
6
7

TMC 8875
TMC 8875
TMC 118100

10465/ST050-465
10466/ST050-466
10466/ST075-467

TCA-50-089
TCA-50-098
TCA-75-106

ST050-465
ST050-466
ST075-467

8
9
10

TMC 118100
TMC 118100
TMC 118100

10467/ST075-467
10467/ST075-467
10468/ST075-468

TCA-75-106
TCA-75-106
TCA-75-118

ST075-467
ST075-467
ST075-468

11
12
15
19

TMC 118100
TMC 118100
TMC 118100
TMC 140125

10468/ST075-468
10468/ST075-468
10469/ST100-469
10469/ST100-469

TCA-75-118
TCA-75-118
TCA-100-135
TCA-100-135

ST075-468
ST075-468
ST100-469
ST100-469

20
25
30
37

TMC 140125
TMC 140125
TMC 166150
TMC 166150

10469/ST100-469
10470/ST125-470
10470/ST125-470
10471/ST125-471

TCA-100-135
TCA-125-151
TCA-125-167
TCA-125-182

ST100-469
ST125-470
ST125-470
ST125-471

40
50
60
80
90

TMC 206200
TMC 206200
TMC 206200
TMC 251250
TMC 251250

10471/ST125-471
10472/ST150-472
10473/ST200-551
10474/ST200-474
10475/ST200-474

TCA-125-182
TCA-150-192
TCA-150-208
TCA-200-231
TCA-200-250

ST125-471
ST150-472
ST200-551
ST200-474
ST200-474

Outer
Covering
inches
mm

Copper
Content

Inner Jacket
Thickness
inches
mm

Number
of
Conductors

Inner
Jacket

Approximate Weight
Aluminum
Armour
lb/kft
kg/km

Insulation
Thickness
inches
mm

* Canadian Electrical Code Table 5C


will apply if cable is used for power
applications or the conductors are
continuously loaded.

Multiconductor TECK 90 (XLPE) Minus 40C

10 AWG 600 V

No. 12 AWG Bonding Conductor


Number
of
Conductors

Ampacity 30 A*
Approximate Diameters

inches

mm

inches

mm

2
3
4

0.030
0.030
0.030

0.76
0.76
0.76

0.045
0.045
0.045

1.14
1.14
1.14

0.452
0.481
0.560

11.48
12.23
14.22

0.684
0.712
0.783

17.37
18.08
19.89

0.769
0.798
0.867

19.53
20.27
22.02

272
339
383

405
504
570

128
176
225

5
6
7

0.030
0.030
0.030

0.76
0.76
0.76

0.060
0.060
0.060

1.52
1.52
1.52

0.604
0.671
0.699

15.35
17.04
17.75

0.833
0.900
0.928

21.16
22.86
23.57

0.918
0.985
1.018

23.32
25.01
25.85

421
517
539

627
770
802

274
323
371

8
9
10

0.030
0.030
0.030

0.76
0.76
0.76

0.060
0.060
0.060

1.52
1.52
1.52

0.726
0.766
0.840

18.44
19.45
21.33

0.954
1.006
1.100

24.23
25.55
27.94

1.047
1.094
1.188

26.59
27.79
30.18

617
633
776

918
942
1154

420
469
518

11
12
15
19

0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.060
0.080
0.080
0.080

1.52
2.03
2.03
2.03

0.879
0.917
0.987
1.066

22.33
23.29
25.06
27.07

1.135
1.178
1.247
1.321

28.83
29.92
31.67
33.55

1.222
1.266
1.335
1.414

31.03
32.16
33.91
35.92

795
885
1056
1209

1183
1318
1571
1800

566
615
761
956

20
25
30
37

0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

1.098
1.229
1.317
1.494

27.89
31.22
33.45
37.96

1.357
1.504
1.573
1.769

34.47
38.20
39.95
44.93

1.445
1.596
1.680
1.864

36.70
40.54
42.67
47.35

1291
1528
1770
2097

1966
2274
2634
3027

1005
1248
1492
1833

40
50
60
80
90

0.030
0.030
0.030
0.030
0.030

0.76
0.76
0.76
0.76
0.76

0.080
0.080
0.110
0.110
0.110

2.03
2.03
2.79
2.79
2.79

1.567
1.701
1.910
2.133
2.246

39.80
43.21
48.50
54.18
57.05

1.917
2.051
2.260
2.483
2.596

48.69
52.10
57.40
63.07
65.94

1.967
2.105
2.314
2.570
2.683

49.96
53.47
58.78
65.28
68.15

2298
2743
3303
4225
4656

3421
4082
4916
6288
6928

1979
2467
2954
3929
4416

Armour

Outer
Covering
inches
mm

Copper
Content

Inner Jacket
Thickness
inches
mm

Number
of
Conductors

Inner
Jacket

Approximate Weight
Aluminum
Armour
lb/kft
kg/km

Insulation
Thickness
inches
mm

kg/km

Fittings
Appleton

T&B

Commander

CrouseHinds

2
3
4

TMC 8875
TMC 8875
TMC 8875

10465/ST050-465
10465/ST050-465
10465/ST050-465

TCA-50-078
TCA-50-089
TCA-50-089

ST050-465
ST050-465
ST050-465

5
6
7

TMC 8875
TMC 118100
TMC 118100

10466/ST050-466
10467/ST075-467
10467/ST075-467

TCA-75-106
TCA-75-106
TCA-75-106

ST050-466
ST075-467
ST075-467

8
9
10

TMC 118100
TMC 118100
TMC 118100

10468/ST075-468
10468/ST075-468
10469/ST100-469

TCA-75-106
TCA-75-118
TCA-100-135

ST075-468
ST075-468
ST100-469

11
12
15
19

TMC 118100
TMC 140125
TMC 140125
TMC 140125

10469/ST100-469
10469/ST100-469
10469/ST100-469
10470/ST125-470

TCA-100-135
TCA-100-135
TCA-100-135
TCA-125-151

ST100-469
ST100-469
ST100-469
ST125-470

20
25
30
37

TMC 140125
TMC 166150
TMC 166150
TMC 206200

10470/ST125-470
10550/ST125-550
10471/ST125-471
10472/ST150-472

TCA-125-151
TCA-125-167
TCA-125-182
TCA-150-192

ST125-470
ST125-550
ST125-471
ST150-472

40
50
60
80
90

TMC 206200
TMC 206200
TMC 251250
TMC 251250
TMC 304300

10473/ST150-473
10551/ST200-551
10474/ST200-474
10553/ST250-477
10553/ST250-478

TCA-150-208
TCA-200-231
TCA-200-250
TCA-250-268
TCA-250-284

ST150-473
ST200-551
ST200-474
ST250-477
ST250-478

* Canadian Electrical Code Table 5C


will apply if cable is used for power
applications or the conductors are
continuously loaded.

Composite Power and Control 600 V TECK 90 (XLPE) Minus 40C


3C Power
Power
AWG

3C 14 AWG or 3C 12 AWG 600 V Control Conductors

Conductor Size
Control
Bonding
AWG
AWG

Power Conductor
Insulation Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Copper
Content
kg/km

12
10
10

14
14
12

14
12
12

0.030
0.030
0.030

0.76
0.76
0.76

0.060
0.060
0.060

1.52
1.52
1.52

0.591
0.596
0.665

15.00
15.14
16.90

0.831
0.836
0.905

21.10
21.23
23.00

0.929
0.936
1.003

23.59
23.77
25.49

169
234
268

8
8
6
6

14
12
14
12

10
10
8
8

0.045
0.045
0.060
0.060

1.14
1.14
1.52
1.52

0.060
0.060
0.080
0.080

1.52
1.52
2.03
2.03

0.715
0.755
0.900
0.914

18.16
19.17
22.86
23.21

0.955
1.010
1.175
1.189

24.26
25.27
29.85
29.82

1.053
1.159
1.288
1.318

26.75
29.43
32.72
33.47

339
373
504
538

4
4
3
3

14
12
14
12

8
8
6
6

0.060
0.060
0.060
0.060

1.52
1.52
1.52
1.52

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

0.904
0.904
0.964
0.964

22.96
22.96
24.48
24.48

1.179
1.179
1.239
1.239

29.57
29.57
31.09
31.09

1.308
1.308
1.368
1.368

33.22
33.22
34.74
34.74

723
757
924
958

2
2
1
1

14
12
14
12

6
6
6
6

0.060
0.060
0.080
0.080

1.52
1.52
2.03
2.03

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

1.026
1.026
1.182
1.182

26.05
26.05
30.03
30.03

1.301
1.301
1.457
1.457

32.66
32.66
36.64
36.64

1.430
1.430
1.586
1.586

36.31
36.31
40.29
40.29

1115
1149
1361
1396

1/0
1/0
2/0
2/0

14
12
14
12

6
6
6
6

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

1.263
1.263
1.348
1.348

32.08
32.08
34.23
34.23

1.538
1.538
1.623
1.623

38.69
38.69
40.84
40.84

1.667
1.667
1.772
1.772

42.34
42.34
44.49
44.49

1667
1701
2055
2089

3/0
3/0
4/0
4/0

14
12
14
12

4
4
4
4

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

1.450
1.450
1.567
1.567

36.82
36.82
39.80
39.80

1.725
1.725
1.872
1.872

43.13
43.13
47.17
47.17

1.854
1.854
2.051
2.051

47.08
47.08
52.09
52.09

2615
2650
3231
3265

Power
AWG

Conductor Size
Control
Bonding
AWG
AWG

Ampacity
30C
Ambient A

Approximate Weight
Aluminum Armour
lb/kft
kg/km

Fittings
Appleton

T&B

Commander

CrouseHinds

12
10
10

14
14
12

14
12
12

20
30
30

380
414
442

566
616
658

TMC 8875
TMC 8875
TMC 118100

10466/ST050-466
10467/ST075-467
10467/ST075-467

TCA-75-106
TCA-75-106
TCA-75-106

ST050-466
ST075-467
ST075-467

8
8
6
6

14
12
14
12

10
10
8
8

45
45
65
65

530
558
700
843

789
883
1042
1254

TMC 118100
TMC 118100
TMC 118100
TMC 140125

10467/ST075-467
10468/ST075-468
10468/ST075-468
10469/ST100-469

TCA-75-118
TCA-75-118
TCA-75-118
TCA-100-135

ST075-467
ST075-468
ST075-468
ST100-469

4
4
3
3

14
12
14
12

8
8
6
6

85
85
105
105

985
1001
1155
1172

1466
1490
1719
1744

TMC 140125
TMC 140125
TMC 140125
TMC 140125

10469/ST100-469
10469/ST100-469
10469/ST100-469
10469/ST100-469

TCA-100-135
TCA-100-135
TCA-125-151
TCA-125-151

ST100-469
ST100-469
ST100-469
ST100-469

2
2
1
1

14
12
14
12

6
6
6
6

120
120
140
140

1322
1339
1609
1626

1967
1992
2394
2420

TMC 140125
TMC 140125
TMC 166150
TMC 166150

10470/ST125-470
10470/ST125-470
10550/ST125-550
10550/ST125-550

TCA-125-151
TCA-125-151
TCA-125-167
TCA-125-167

ST125-470
ST125-470
ST125-550
ST125-550

1/0
1/0
2/0
2/0

14
12
14
12

6
6
6
6

155
155
185
185

1823
1885
2218
2235

2781
2805
3300
3326

TMC 166150
TMC 166150
TMC 166150
TMC 166150

10471/ST125-471
10471/ST125-471
10471/ST125-471
10471/ST125-471

TCA-125-167
TCA-125-167
TCA-125-182
TCA-125-182

ST125-471
ST125-471
ST125-471
ST125-471

3/0
3/0
4/0
4/0

14
12
14
12

4
4
4
4

210
210
235
235

2667
2683
3294
3312

3969
3993
4902
4929

TMC 206200
TMC 206200
TMC 206200
TMC 206200

10472/ST150-472
10472/ST150-472
10473/ST150-473
10473/ST150-473

TCA-150-192
TCA-150-192
TCA-150-208
TCA-150-208

ST150-472
ST150-472
ST150-473
ST150-473

10

1C TECK 90 (XLPE) Minus 40C 1000 V


with Concentric Bonding Conductor
Conductor Size
Power AWG Bonding
or kcmil
AWG

*Aluminum Armour Only

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour*
lb/kft
kg/km

Copper
Content
kg/km

6
4

8
6

0.060
0.060

1.52
1.52

0.030
0.030

0.76
0.76

0.453
0.497

11.50
12.63

0.693
0.737

17.60
18.72

0.791
0.835

20.09
21.21

331
428

493
637

210
330

3
2
1

6
6
4

0.060
0.060
0.080

1.52
1.52
2.03

0.030
0.030
0.045

0.76
0.76
1.14

0.525
0.555
0.658

13.33
14.10
16.70

0.765
0.795
0.898

19.43
20.19
22.81

0.863
0.893
0.996

21.92
22.68
25.30

473
528
696

704
786
1036

382
446
599

1/0
2/0
3/0
4/0

4
4
3
3

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

0.045
0.045
0.045
0.045

1.14
1.14
1.14
1.14

0.725
0.750
0.807
0.859

18.42
19.05
20.49
21.82

0.965
1.025
1.070
1.134

24.51
26.04
27.18
28.80

1.069
1.135
1.180
1.244

27.15
28.83
29.97
31.60

781
944
1121
1272

1162
1405
1668
1893

701
830
1051
1257

250
300
350

2
2
1

0.090
0.090
0.090

2.29
2.29
2.29

0.060
0.060
0.060

1.52
1.52
1.52

0.955
1.005
1.080

24.25
25.53
27.43

1.247
1.280
1.353

31.67
32.51
34.37

1.355
1.409
1.465

34.42
35.79
37.21

1466
1715
1947

2181
2552
2897

1500
1733
2062

400
500

1
1/0

0.090
0.090

2.29
2.29

0.060
0.060

1.52
1.52

1.123
1.237

28.53
31.42

1.398
1.514

35.51
38.46

1.527
1.625

38.79
41.28

2164
2596

3220
3863

2299
2864

600
1/0
0.090
2.29
0.060
1.52
1.278
750
2/0
0.090
2.29
0.060
1.52
1.408
1000
2/0
0.090
2.29
0.060
1.52
1.561
*Steel armour is not permitted in single conductor cables.

32.47
35.75
39.64

1.553
1.683
1.911

39.45
42.75
48.53

1.682
1.812
2.045

42.72
46.02
51.94

2960
3648
4674

4405
5429
6955

3332
4189
5359

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Ampacity
30C
Ambient A

Fittings
Appleton

T&B

Commander

CrouseHinds

6
4

8
6

100
135

TMC8875
TMC8875

10465AL/ST050-465
10465AL/ST050-465

TCA-50-089
TCA-50-089

ST050-465
ST050-465

3
2
1

6
6
4

155
180
210

TMC8875
TMC8875
TMC118100

10465AL/ST050-465
10466AL/ST050-466
10467AL/ST075-467

TCA-50-089
TCA-50-098
TCA-75-106

ST050-465
ST050-466
ST075-467

1/0
2/0
3/0
4/0

4
4
3
3

245
285
330
385

TMC118100
TMC118100
TMC118100
TMC140125

10467AL/ST075-467
10468AL/ST075-468
10468AL/ST075-468
10469AL/ST100-469

TCA-75-106
TCA-75-118
TCA-100-135
TCA-100-135

ST075-467
ST075-468
ST075-468
ST100-469

250
300
350

2
2
1

425
480
530

TMC140125
TMC140125
TMC140125

10469AL/ST100-469
10470AL/ST125-470
10470AL/ST125-470

TCA-125-151
TCA-125-151
TCA-125-151

ST100-469
ST125-470
ST125-470

400
500

1
1/0

575
660

TMC140125
TMC140125

10470AL/ST125-470
10550AL/ST125-550

TCA-125-167
TCA-125-167

ST125-470
ST125-550

600
1/0
740
TMC140125
10471AL/ST125-471
TCA-125-182
ST125-471
750
2/0
845
TMC206200
10472AL/ST150-472
TCA-150-192
ST150-472
1000
2/0
1000
TMC206200
10472AL/ST150-473
TCA-150-208
ST150-473
Ensure that only nonmagnetic connectors, locknuts and ground bushings are used.

11

2C TECK 90 (XLPE) Minus 40C 1000 V

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour
lb/kft
kg/km

Copper
Content
kg/km

14
12
10

14
14
12

0.045
0.045
0.045

1.14
1.14
1.14

0.045
0.045
0.045

1.14
1.14
1.14

0.423
0.464
0.510

10.74
11.78
12.95

0.663
0.696
0.750

16.84
17.67
19.05

0.761
0.794
0.848

19.32
20.17
21.54

216
272
296

321
405
440

57
80
128

8
6
4

10
8
8

0.045
0.060
0.060

1.14
1.52
1.52

0.060
0.060
0.060

1.52
1.52
1.52

0.590
0.718
0.812

14.98
18.25
20.61

0.819
0.945
1.084

20.80
24.00
27.53

0.926
1.055
1.188

23.52
26.80
30.18

407
545
742

606
811
1104

203
323
469

3
2
1

6
6
6

0.060
0.060
0.080

1.52
1.52
2.03

0.080
0.080
0.080

2.03
2.03
2.03

0.902
0.963
1.110

22.91
24.45
28.20

1.177
1.235
1.385

29.90
31.37
35.18

1.306
1.339
1.514

33.17
34.01
38.45

912
1029
1252

1357
1531
1863

618
746
910

1/0
2/0
3/0
4/0

6
6
4
4

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

1.185
1.263
1.358
1.463

30.09
32.09
34.50
37.16

1.454
1.533
1.633
1.731

36.93
38.94
41.48
43.97

1.558
1.641
1.762
1.863

39.57
41.68
44.75
47.32

1451
1675
2031
2385

2159
2493
3022
3549

1114
1372
1770
2181

250
300
350
400
500

4
4
3
3
3

0.090
0.090
0.090
0.090
0.090

2.29
2.29
2.29
2.29
2.29

0.080
0.080
0.110
0.110
0.110

2.03
2.03
2.79
2.79
2.79

1.598
1.699
1.852
1.938
2.097

40.59
43.15
47.03
49.23
53.27

1.948
2.049
2.202
2.288
2.447

49.48
52.04
55.93
58.11
62.15

2.082
2.183
2.336
2.422
2.581

52.88
55.44
59.33
61.52
65.56

2870
3281
3837
4236
5082

4270
4882
5710
6303
7563

2542
3008
3530
4004
4934

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Ampacity
30C
Ambient A

Fittings
Appleton

T&B

Commander

CrouseHinds

14
12
10

14
14
12

15
20
30

TMC8875
TMC8875
TMC8875

10465/ST050-465
10465/ST050-465
10465/ST050-465

TCA-50-078
TCA-50-089
TCA-50-089

ST050-465
ST050-465
ST050-465

8
6
4

10
8
8

45
65
85

TMC8875
TMC118100
TMC118100

10466/ST050-466
10467/ST075-467
10468/ST075-468

TCA-75-106
TCA-75-118
TCA-100-135

ST050-466
ST075-467
ST075-468

3
2
1

6
6
6

105
120
140

TMC140125
TMC140125
TMC166150

10469/ST100-469
10469/ST100-469
10470/ST125-470

TCA-100-135
TCA-100-135
TCA-125-151

ST100-469
ST100-469
ST125-470

1/0
2/0
3/0
4/0

6
6
4
4

155
185
210
235

TMC166150
TMC166150
TMC166150
TMC206200

10550/ST125-550
10471/ST125-471
10471/ST125-471
10472/ST150-472

TCA-125-167
TCA-125-167
TCA-125-182
TCA-150-192

ST125-550
ST125-471
ST125-471
ST150-472

250
300
350
400
500

4
4
3
3
3

265
295
325
345
395

TMC206200
TMC251250
TMC251250
TMC251250
TMC251250

10473/ST150-473
10474/ST200-474
10474/ST200-474
10475/ST200-475
10476/ST200-476

TCA-150-208
TCA-200-231
TCA-200-250
TCA-200-250
TCA-250-268

ST150-473
ST200-474
ST200-474
ST200-475
ST200-476

12

3C TECK 90 (XLPE) Minus 40C 1000 V

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour
lb/kft kg/km

Copper
Content
lb/kft

14
12
10

14
14
12

0.045
0.045
0.045

1.14
1.14
1.14

0.045
0.045
0.060

0.14
0.14
1.52

0.448
0.503
0.576

11.38
12.77
14.63

0.685
0.735
0.807

17.40
18.67
20.50

0.770
0.821
0.891

19.56
20.85
22.63

247
297
381

367
441
567

77
111
176

8
6
4

10
8
8

0.045
0.060
0.060

1.14
1.52
1.52

0.060
0.060
0.080

1.52
1.52
2.03

0.627
0.766
0.904

15.93
19.44
22.96

0.855
1.035
1.176

21.72
26.29
29.87

0.942
1.125
1.265

23.93
28.58
32.13

491
644
924

730
959
1375

281
446
665

3
2
1

6
6
6

0.060
0.060
0.080

1.52
1.52
2.03

0.080
0.080
0.080

2.03
2.03
2.03

0.964
1.026
1.182

24.48
26.05
30.03

1.236
1.300
1.457

31.39
33.02
37.01

1.326
1.388
1.547

33.68
35.26
39.29

1026
1274
1539

1526
1896
2291

866
1057
1304

1/0
2/0
3/0
4/0

6
6
4
4

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

1.263
1.348
1.450
1.567

32.08
34.23
36.82
39.80

1.537
1.621
1.725
1.815

39.04
41.17
43.82
46.10

1.630
1.729
1.835
1.925

41.40
43.92
46.61
48.90

1796
2165
2571
3196

2672
3222
3827
4733

1609
1997
2558
3173

250
300
350
400
500

4
4
3
3
3

0.090
0.090
0.090
0.090
0.090

2.29
2.29
2.29
2.29
2.29

0.110
0.110
0.110
0.110
0.110

2.79
2.79
2.79
2.79
2.79

1.768
1.877
1.976
2.074
2.241

44.91
47.67
50.20
52.68
56.92

2.120
2.235
2.330
2.422
2.595

53.85
56.77
59.18
61.52
65.91

2.250
2.367
2.462
2.554
2.757

57.15
60.12
62.53
64.87
70.03

3830
4382
4990
5534
6674

5700
6520
7426
8235
9932

3716
4414
5171
5883
7278

600
750

2
2

0.090
0.090

2.29
2.29

0.110
0.110

2.79
2.79

2.408
2.614

61.17
66.40

2.758
2.959

70.05
75.16

2.935
3.121

74.55
79.27

7747 11528
9596 14281

8747
10872

Conductor Size
Power AWG Bonding
or kcmil
AWG

Ampacity
30C
Ambient A

Fittings
Appleton

T&B

Commander

CrouseHinds

14
12
10

14
14
12

15
20
30

TMC8875
TMC8875
TMC8875

10465/ST050-465
10465/ST050-465
10466/ST050-466

TCA-50-078
TCA-50-089
TCA-50-098

ST050-465
ST050-465
ST050-466

8
6
4

10
8
8

45
65
85

TMC8875
TMC118100
TMC118100

10467/ST075-467
10468/ST075-468
10469/ST100-469

TCA-75-106
TCA-75-118
TCA-100-135

ST075-467
ST075-468
ST100-469

3
2
1

6
6
6

105
120
140

TMC118100
TMC118100
TMC166150

10469/ST100-469
10470/ST125-470
10470/ST125-470

TCA-100-135
TCA-125-151
TCA-125-167

ST100-469
ST125-470
ST125-470

1/0
2/0
3/0
4/0

6
6
4
4

155
185
210
235

TMC166150
TMC166150
TMC206200
TMC206200

10471/ST125-471
10471/ST125-471
10472/ST150-472
10472/ST150-473

TCA-125-167
TCA-125-182
TCA-150-192
TCA-150-208

ST125-471
ST125-471
ST150-472
ST150-473

250
300
350
400
500

4
4
3
3
3

265
295
325
345
395

TMC251250
TMC251250
TMC251250
TMC251250
TMC304300

10474/ST200-474
10475/ST200-474
10475/ST200-475
10552/ST250-477
10477/ST250-478

TCA-200-231
TCA-200-250
TCA-200-250
TCA-250-268
TCA-250-284

ST200-474
ST200-474
ST200-475
ST250-477
ST250-478

600
750

2
2

455
500

TMC304300
TMC304300

10477/ST300-479
10555/ST300-480

TCA-250-300
TCA-300-322

ST300-479
ST300-480

13

4C TECK 90 (XLPE) Minus 40C 1000 V

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour
lb/kft
kg/km

Copper
Content
kg/km

14
12
10

14
14
12

0.045
0.045
0.045

1.14
1.14
1.14

0.045
0.060
0.060

1.14
1.52
1.52

0.493
0.569
0.632

12.52
14.46
16.04

0.733
0.809
0.878

18.61
20.33
22.30

0.827
0.903
0.965

21.00
22.94
24.51

282
356
436

420
530
649

96
141
225

8
6
4

10
8
8

0.045
0.060
0.060

1.14
1.52
1.52

0.060
0.080
0.080

1.52
2.03
2.03

0.694
0.895
0.995

17.62
22.73
25.27

0.921
1.170
1.270

23.39
29.71
32.26

1.028
1.280
1.351

26.11
32.51
34.31

583
838
1122

867
1247
1669

358
569
861

3
2
1

6
6
6

0.060
0.060
0.080

1.52
1.52
2.03

0.080
0.080
0.080

2.03
2.03
2.03

1.085
1.145
1.303

27.55
29.09
33.11

1.360
1.420
1.578

34.54
36.07
39.50

1.441
1.501
1.663

36.60
38.13
42.24

1359
1580
1927

2022
2351
2868

1114
1369
1697

1/0
2/0
3/0
4/0

6
6
4
4

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

0.080
0.080
0.080
0.110

2.03
2.03
2.03
2.79

1.394
1.488
1.607
1.793

35.40
37.81
40.81
45.55

1.669
1.757
1.852
2.033

42.39
44.63
47.04
51.64

1.774
1.865
1.960
2.141

45.06
47.37
49.78
54.38

2295
2711
3395
4197

3415
4034
5053
6239

2105
2621
3345
4166

250
300
350

4
4
3

0.090
0.090
0.090

2.29
2.29
2.29

0.110
0.110
0.110

2.79
2.79
2.79

1.952
2.077
2.189

49.57
52.76
55.60

2.302
2.427
2.539

58.52
61.65
64.49

2.417
2.542
2.654

59.59
65.57
67.41

4828
5630
6399

7230
8378
9522

4889
5820
6813

400
500

3
3

0.090
0.090

2.29
2.29

0.110
0.110

2.79
2.79

2.294
2.481

58.26
63.02

2.644
2.831

67.16
71.91

2.833
3.020

71.96
76.71

7132
8555

10613
12732

7761
9622

Conductor Size
Power AWG Bonding
or kcmil
AWG

Ampacity**
30C
Ambient A

Fittings
Appleton

T&B

Commander

CrouseHinds

14
12
10

14
14
12

15
20
30

TMC-8875
TMC-8875
TMC-118100

10465/ST050-465
10466/ST050-466
10467/ST075-467

TCA-50-089
TCA-50-098
TCA-75-106

ST050-465
ST050-466
ST075-467

8
6
4

10
8
8

45
65
85

TMC-118100
TMC-118100
TMC-140125

10467/ST075-467
10469/ST100-469
10469/ST100-469

TCA-75-106
TCA-100-135
TCA-100-135

ST075-467
ST100-469
ST100-469

3
2
1

6
6
6

105
120
140

TMC-140125
TMC-166150
TMC-166150

10470/ST125-470
10470/ST125-470
10471/ST125-471

TCA-125-151
TCA-125-151
TCA-125-167

ST125-470
ST125-470
ST125-550

1/0
2/0
3/0
4/0

6
6
4
4

155
185
210
235

TMC-206200
TMC-206200
TMC-206200
TMC-206200

10472/ST150-472
10472/ST150-472
10473/ST200-551
10551/ST200-474

TCA-150-192
TCA-150-192
TCA-150-208
TCA-200-231

ST150-472
ST150-472
ST200-551
ST200-474

250
300
350

4
4
3

265
295
325

TMC-251250
TMC-251250
TMC-304300

10475/ST200-475
10552/ST250-477
10553/ST250-478

TCA-200-250
TCA-250-268
TCA-250-268

ST200-475
ST250-477
ST250-478

400
3
345
TMC-304300
10477/ST250-478
TCA-250-284
ST250-478
500
3
395
TMC-304300
10554/ST300-479
TCA-300-322
ST300-479
**Where fourth conductor is neutral of a three phase, four wire system; otherwise 80% of
these values CEC Rule 4-004(3).

14

1C TECK 90 (XLPE) Minus 40C

5 kV Unshielded

with Concentric Bonding Conductor


Conductor Size
Power AWG Bonding
or kcmil
AWG

*Aluminum Armour Only

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour*
lb/kft
kg/km

Copper
Content
kg/km

6
4

8
6

0.090
0.090

2.29
2.29

0.030
0.045

0.76
1.14

0.545
0.620

13.84
15.75

0.785
0.860

19.94
21.84

0.880
0.953

22.35
24.21

385
513

573
780

210
330

3
2
1

6
6
4

0.090
0.090
0.090

2.29
2.29
2.29

0.045
0.045
0.045

1.14
1.14
1.14

0.645
0.675
0.724

16.38
17.15
18.39

0.885
0.915
0.964

22.48
23.24
24.49

0.980
1.010
1.062

24.89
25.65
26.97

571
641
737

850
954
1097

382
446
599

1/0
2/0
3/0
4/0

4
4
3
3

0.090
0.090
0.090
0.090

2.29
2.29
2.29
2.29

0.045
0.045
0.045
0.060

1.14
1.14
1.14
1.52

0.767
0.804
0.855
0.935

19.48
20.43
21.72
23.75

1.042
1.079
1.130
1.210

26.47
27.41
28.70
30.73

1.146
1.185
1.234
1.314

29.11
30.10
31.34
33.38

964
975
1211
1413

1435
1451
1802
2103

701
830
1051
1257

250
300
350

2
2
1

0.090
0.090
0.090

2.29
2.29
2.29

0.060
0.060
0.060

1.52
1.52
1.52

1.019
1.069
1.115

25.88
27.15
28.32

1.294
1.344
1.390

32.87
34.14
35.31

1.405
1.457
1.500

35.69
37.00
38.10

1607
1792
1971

2391
2666
2933

1500
1733
2062

400
500

1
1/0

0.090
0.090

2.29
2.29

0.060
0.060

1.52
1.52

1.169
1.269

29.69
32.23

1.444
1.544

36.68
39.22

1.573
1.669

39.95
42.39

2155
2692

3207
4006

2299
2864

600
1/0
0.090
2.29
0.060
1.52
1.348
750
2/0
0.090
2.29
0.060
1.52
1.454
1000
2/0
0.090
2.29
0.060
1.52
1.631
*Steel armour is not permitted in single conductor cables.

34.25
36.93
41.41

1.623
1.729
1.981

41.22
43.92
50.32

1.752
1.854
2.115

44.50
47.09
53.72

2993
3722
4652

4454
5539
6923

3332
4189
5359

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Ampacity
30C
Ambient A

Fittings
Appleton

T&B

Commander

CrouseHinds

6
4

8
6

100
135

TMC8875
TMC8875

10466AL/ST050-466
10467AL/ST075-467

TCA-50-089
TCA-75-106

ST050-466
ST075-467

3
2
1

6
6
4

155
180
210

TMC118100
TMC118100
TMC118100

10467AL/ST075-467
10467AL/ST075-467
10467AL/ST075-467

TCA-75-106
TCA-75-106
TCA-75-118

ST075-467
ST075-467
ST075-467

1/0
2/0
3/0
4/0

4
4
3
3

245
285
330
385

TMC118100
TMC118100
TMC118100
TMC140125

10468AL/ST075-468
10469AL/ST075-468
10469AL/ST100-469
10469AL/ST100-469

TCA-75-118
TCA-100-135
TCA-100-135
TCA-100-135

ST075-468
ST075-468
ST100-469
ST100-469

250
300
350

2
2
1

425
480
530

TMC140125
TMC140125
TMC166150

10470AL/ST125-470
10470AL/ST125-470
10470AL/ST125-470

TCA-125-151
TCA-125-151
TCA-125-167

ST125-470
ST125-470
ST125-470

400
500

1
1/0

575
660

TMC166150
TMC166150

10550AL/ST125-550
10471AL/ST125-471

TCA-125-167
TCA-125-182

ST125-550
ST125-471

600
1/0
740
TMC166150
750
2/0
845
TMC206200
1000
2/0
1000
TMC206200
Ensure that only nonmagnetic connectors,

10471AL/ST125-471
10472AL/ST150-472
10551AL/ST200-551
locknuts and ground

TCA-125-182
ST125-471
TCA-150-192
ST150-472
TCA-200-231
ST200-551
bushings are used.

15

1C TECK 90 (XLPE) Minus 40C

5 kV Shielded
**100/133% Insulation Level

with Concentric Bonding Conductor

*Aluminum Armour Only


Conductor Size
Power AWG Bonding
or kcmil
AWG

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour*
lb/kft
kg/km

Copper
Content
kg/km

6
4

8
6

0.090
0.090

2.29
2.29

0.045
0.045

1.14
1.14

0.631
0.705

16.02
17.91

0.871
0.945

22.12
24.00

0.969
1.043

24.61
26.49

431
563

641
838

210
330

3
2
1

6
6
4

0.090
0.090
0.090

2.29
2.29
2.29

0.060
0.060
0.060

1.52
1.52
1.52

0.736
0.768
0.821

18.69
19.50
20.85

0.976
1.043
1.096

24.79
26.49
27.84

1.080
1.147
1.200

27.43
29.13
30.48

630
750
880

938
1116
1310

382
446
599

1/0
2/0
3/0
4/0

4
4
3
3

0.090
0.090
0.090
0.090

2.29
2.29
2.29
2.29

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

0.898
0.973
0.986
1.036

22.81
24.71
25.04
26.31

1.173
1.212
1.261
1.311

29.79
30.78
32.03
33.30

1.277
1.316
1.365
1.415

32.44
33.43
34.67
35.94

927
1037
1315
1478

1379
1543
1957
2200

701
830
1051
1257

250
300
350

2
2
1

0.090
0.090
0.090

2.29
2.29
2.29

0.080
0.080
0.080

2.03
2.03
2.03

1.125
1.175
1.216

28.57
29.85
30.88

1.400
1.450
1.491

35.56
36.83
37.87

1.504
1.560
1.596

38.20
39.62
40.54

1700
1892
2196

2530
2815
3268

1500
1733
2062

400
500

1
1/0

0.090
0.090

2.29
2.29

0.080
0.080

2.03
2.03

1.265
1.357

32.13
34.47

1.540
1.632

39.12
41.45

1.665
1.757

42.29
44.63

2375
2813

3534
4186

2299
2864

600
1/0
0.090
2.29
0.080
2.03
1.441
36.61
1.716
43.59
1.845
46.86
3117
4638
750
2/0
0.090
2.29
0.080
2.03
1.574
39.99
1.924
48.87
2.058
52.27
3905
5811
1000
2/0
0.090
2.29
0.110
2.79
1.789
45.44
2.139
54.33
2.265
57.53
5025
7478
*Steel armour is not permitted in single conductor cable.
**CSA C68.397 (R2001) requires 0.090" (2.29mm) insulation thickness for both 100% and 133% insulation levels.

3332
4189
5359

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Ampacity
30C
Ambient A

Appleton

T&B

Fittings
Commander

CrouseHinds

6
4

8
6

100
135

TMC-118100
TMC-118100

10467AL/ST075-467
10467AL/ST075-467

TCA-75-106
TCA-75-106

ST075-467
ST075-467

3
2
1

6
6
4

155
180
210

TMC-118100
TMC-118100
TMC-118100

10468AL/ST075-468
10468AL/ST075-468
10469AL/ST100-469

TCA-75-118
TCA-75-118
TCA-100-135

ST075-468
ST075-468
ST100-469

1/0
2/0
3/0
4/0

4
4
3
3

245
285
330
385

TMC-140125
TMC-140125
TMC-140125
TMC-140125

10469AL/ST100-469
10469AL/ST100-469
10469AL/ST100-469
10470AL/ST125-470

TCA-100-135
TCA-100-135
TCA-125-151
TCA-125-151

ST100-469
ST100-469
ST100-469
ST125-470

250
300
350

2
2
1

425
480
530

TMC-166150
TMC-166150
TMC-166150

10470AL/ST125-470
10550AL/ST125-550
10550AL/ST125-550

TCA-125-167
TCA-125-167
TCA-125-167

ST125-470
ST125-550
ST125-550

400
500

1
1/0

575
660

TMC-166150
TMC-206200

10471AL/ST125-471
10471AL/ST150-472

TCA-125-167
TCA-125-182

ST125-471
ST150-472

600
1/0
740
TMC-206200
10472AL/ST150-472
TCA-150-192
ST150-472
750
2/0
845
TMC-206200
10473AL/ST150-473
TCA-150-208
ST150-473
1000
2/0
1000
TMC-251250
10474AL/ST200-474
TCA-200-231
ST200-474
Ensure that only nonmagnetic connectors, locknuts and ground bushings are used.

16

3C TECK 90 (XLPE) Minus 40C

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

5 kV Unshielded

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour
lb/kft
kg/km

Copper
Content
kg/km

8
6
4

10
8
8

0.090
0.090
0.090

2.29
2.29
2.29

0.060
0.080
0.080

1.52
2.03
2.03

0.931
1.051
1.146

23.64
26.69
29.11

1.206
1.326
1.421

30.63
33.68
36.09

1.315
1.435
1.530

33.40
36.45
38.86

721
872
1155

1073
1298
1720

281
446
665

3
2
1

6
6
6

0.090
0.090
0.090

2.29
2.29
2.29

0.080
0.080
0.080

2.03
2.03
2.03

1.200
1.266
1.335

30.49
32.15
33.91

1.475
1.541
1.610

37.46
39.14
40.89

1.584
1.670
1.739

40.23
42.42
44.17

1322
1503
1732

1968
2237
2578

866
1057
1304

1/0
2/0
3/0
4/0

6
6
4
4

0.090
0.090
0.090
0.090

2.29
2.29
2.29
2.29

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

1.415
1.500
1.606
1.724

35.95
38.10
40.80
43.79

1.690
1.775
1.956
2.074

42.93
45.09
49.68
52.68

1.819
1.904
2.090
2.208

46.20
48.36
53.09
56.08

2013
2339
2929
3544

2997
3481
4359
5274

1609
1997
2558
3173

250
300
350

4
4
3

0.090
0.090
0.090

2.29
2.29
2.29

0.110
0.110
0.110

2.79
2.79
2.79

1.882
1.990
2.094

47.80
50.55
53.19

2.232
2.340
2.444

56.69
59.44
62.08

2.366
2.474
2.578

60.10
62.84
65.48

4032
4605
5242

6001
6852
7800

3716
4414
5171

400
500

3
3

0.090
0.090

2.29
2.29

0.110
0.110

2.79
2.79

2.188
2.355

55.56
59.81

2.538
2.705

64.47
68.71

2.672
2.839

67.87
72.11

5852 8709
7053 10495

5883
7278

Conductor Size
Power AWG Bonding
or kcmil
AWG

Ampacity
30C
Ambient A

Fittings
Appleton

T&B

Commander

CrouseHinds

8
6
4

10
8
8

45
65
85

TMC-140125
TMC-140125
TMC-166150

10469/ST100-469
10470/ST125-470
10470/ST125-550

TCA-100-135
TCA-125-151
TCA-125-167

ST100-469
ST125-470
ST125-550

3
2
1

6
6
6

105
120
140

TMC-166150
TMC-166150
TMC-166150

10550/ST125-550
10471/ST125-471
10471/ST150-472

TCA-125-167
TCA-125-182
TCA-125-182

ST125-550
ST125-471
ST150-472

1/0
2/0
3/0
4/0

6
6
4
4

155
185
210
235

TMC-206200
TMC-206200
TMC-206200
TMC-251250

10472/ST150-472
10472/ST150-472
10473/ST200-551
10474/ST200-474

TCA-150-192
TCA-150-208
TCA-200-231
TCA-200-231

ST150-472
ST150-472
ST200-551
ST200-474

250
300
350

4
4
3

265
295
325

TMC-251250
TMC-251250
TMC-251250

10475/ST200-475
10552/ST200-475
10553/ST250-477

TCA-200-250
TCA-200-250
TCA-250-268

ST200-475
ST200-475
ST250-477

400
500

3
3

345
395

TMC-304300
TMC-304300

10553/ST250-478
10477/ST300-479

TCA-250-284
TCA-250-300

ST250-478
ST300-479

17

3C TECK 90 (XLPE) Minus 40C

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

5 kV Shielded
*100/133% Insulation Level

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour
lb/kft
kg/km

Copper
Content
kg/km

8
6
4

10
8
8

0.090
0.090
0.090

2.29
2.29
2.29

0.080
0.080
0.080

2.03
2.03
2.03

1.147
1.225
1.321

29.14
31.12
33.55

1.422
1.500
1.596

36.11
38.10
40.54

1.531
1.609
1.725

38.88
40.87
43.82

986
1165
1397

1467
1734
2078

281
446
665

3
2
1

6
6
6

0.090
0.090
0.090

2.29
2.29
2.29

0.080
0.080
0.080

2.03
2.03
2.03

1.375
1.440
1.510

34.93
36.58
38.35

1.650
1.715
1.830

41.91
43.56
46.48

1.779
1.844
1.994

45.19
46.84
50.63

1611
1801
2029

2397
2680
3019

866
1057
1304

1/0
2/0
3/0
4/0

6
6
4
4

0.090
0.090
0.090
0.090

2.29
2.29
2.29
2.29

0.080
0.080
0.110
0.110

2.03
2.03
2.79
2.79

1.594
1.679
1.846
1.959

40.49
42.64
46.88
49.75

1.944
2.029
2.196
2.309

49.38
51.54
55.79
58.65

2.078
2.163
2.330
2.443

52.78
54.94
59.18
62.05

2443
2790
3411
3948

3635
4152
5076
5875

1609
1997
2558
3173

250
300
350

4
4
3

0.090
0.090
0.090

2.29
2.29
2.29

0.110
0.110
0.110

2.79
2.79
2.79

2.085
2.194
2.294

52.96
55.72
58.26

2.435
2.544
2.644

61.85
64.62
67.16

2.569
2.678
2.778

65.25
68.02
70.56

4531
5126
5752

6742
7628
8559

3716
4414
5171

400
3
0.090
2.29
0.110
2.79
2.387
60.63
2.737
69.52
2.871
72.92
6341
9436
500
3
0.090
2.29
0.110
2.79
2.554
64.87
2.904
73.76
3.038
77.17
7476
11125
*CSA C68.397 (R2001) requires 0.090" (2.29mm) insulation thickness for both 100% and 133% insulation levels.

5883
7278

Conductor Size
Power AWG Bonding
or kcmil
AWG

Ampacity
30C
Ambient A

Fittings
Appleton

T&B

Commander

CrouseHinds

8
6
4

10
8
8

45
65
85

TMC-166150
TMC-166150
TMC-166150

10550/ST125-470
10550/ST125-550
10471/ST125-471

TCA-125-167
TCA-125-167
TCA-125-182

ST125-470
ST125-550
ST125-471

3
2
1

6
6
6

105
120
140

TMC-206200
TMC-206200
TMC-206200

10471/ST150-472
10472/ST150-472
10473/ST150-473

TCA-125-182
TCA-150-192
TCA-150-208

ST150-472
ST150-472
ST150-473

1/0
2/0
3/0
4/0

6
6
4
4

155
185
210
235

TMC-206200
TMC-251200
TMC-251200
TMC-251200

10473/ST200-551
10551/ST200-474
10474/ST200-474
10475/ST200-475

TCA-150-208
TCA-200-231
TCA-200-250
TCA-200-250

ST200-551
ST200-474
ST200-474
ST200-475

250
300
350

4
4
3

265
295
325

TMC-251200
TMC-304300
TMC-304300

10476/ST250-477
10553/ST250-478
10477/ST250-478

TCA-250-268
TCA-250-284
TCA-250-284

ST250-477
ST250-478
ST250-478

400
500

3
3

345
395

TMC-304300
TMC-304300

10477/ST300-479
10554/ST300-479

TCA-250-300
TCA-300-322

ST300-479
ST300-479

18

1C TECK 90 (XLPE) Minus 40C

8 kV 100% Insulation Level

with Concentric Bonding Conductor


Conductor Size
Power AWG Bonding
or kcmil
AWG

*Aluminum Armour Only

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour*
lb/kft
kg/km

Copper
Content
kg/km

6
4

8
6

0.115
0.115

2.92
2.92

0.060
0.060

1.52
1.52

0.742
0.790

18.83
20.06

0.982
1.065

24.94
27.05

1.080
1.174

27.43
29.82

512
663

762
987

210
330

3
2
1

6
6
4

0.115
0.115
0.115

2.92
2.92
2.92

0.060
0.060
0.060

1.52
1.52
1.52

0.815
0.845
0.878

20.70
21.47
22.29

1.090
1.120
1.153

27.69
28.45
29.29

1.199
1.229
1.262

30.45
31.22
32.05

713
776
901

1061
1155
1341

382
446
599

1/0
2/0
3/0
4/0

4
4
3
3

0.115
0.115
0.115
0.115

2.92
2.92
2.92
2.92

0.060
0.060
0.080
0.080

1.52
1.52
2.03
2.03

0.915
0.954
1.064
1.117

23.24
24.23
27.04
28.37

1.190
1.229
1.339
1.392

30.23
31.22
34.01
35.36

1.299
1.338
1.448
1.501

32.99
33.98
36.78
38.13

993
1105
1344
1519

1478
1644
2000
2260

701
830
1051
1257

250
300
350

2
2
1

0.115
0.115
0.115

2.92
2.92
2.92

0.080
0.080
0.080

2.03
2.03
2.03

1.174
1.224
1.297

29.81
31.09
32.94

1.449
1.499
1.572

36.80
38.07
39.93

1.558
1.608
1.701

39.57
40.84
43.21

1709
1901
2163

2543
2829
3219

1500
1733
2062

400
500

1
1/0

0.115
0.115

2.92
2.92

0.080
0.080

2.03
2.03

1.340
1.442

34.04
36.62

1.615
1.717

41.02
43.61

1.744
1.846

44.30
46.89

2384
2865

3548
4263

2299
2864

600
1/0
0.115
2.92
0.080
2.03
1.532
750
2/0
0.115
2.92
0.080
2.03
1.665
1000
2/0
0.115
2.92
0.080
2.03
1.819
*Steel armour is not permitted in single conductor cable.

38.91
42.29
46.21

1.852
2.015
2.169

47.04
51.18
55.09

2.016
2.149
2.303

51.21
54.58
58.50

3232
4031
4953

4810
5998
7371

3332
4189
5359

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Ampacity**
40C
Ambient A

Appleton

T&B

Fittings
Commander

CrouseHinds

6
4

8
6

112
148

TMC118100
TMC118100

10468AL/ST075-468
10469AL/ST075-468

TCA-75-118
TCA-75-118

ST075-468
ST075-468

3
2
1

6
6
4

170
195
225

TMC118100
TMC118100
TMC140125

10469AL/ST100-469
10469AL/ST100-469
10469AL/ST100-469

TCA-100-135
TCA-100-135
TCA-100-135

ST100-469
ST100-469
ST100-469

1/0
2/0
3/0
4/0

4
4
3
3

260
299
345
400

TMC140125
TMC140125
TMC140125
TMC166150

10469AL/ST100-469
10469AL/ST100-469
10470AL/ST125-470
10470AL/ST125-470

TCA-100-135
TCA-125-151
TCA-125-151
TCA-125-167

ST100-469
ST100-469
ST125-470
ST125-470

250
300
350

2
2
1

444
500
549

TMC166150
TMC166150
TMC166150

10550AL/ST125-550
10550AL/ST125-550
10471AL/ST125-471

TCA-125-167
TCA-125-167
TCA-125-182

ST125-550
ST125-550
ST125-471

400
500

1
1/0

587
688

TMC166150
TMC206200

10471AL/ST125-471
10472AL/ST150-472

TCA-125-182
TCA-150-192

ST125-471
ST150-472

600
1/0
766
TMC206200
10473AL/ST150-473
TCA-150-208
ST150-473
750
2/0
889
TMC206200
10551AL/ST200-551
TCA-200-231
ST200-551
1000
2/0
1061
TMC206200
10474AL/ST200-474
TCA-200-250
ST200-474
**Per ICEA Publication P-46-426 for 90C conductor, 40C ambient air, cables spaced at least one
diameter apart in free air. Other conditions may require derating. Inspection authority agreement is required
to use these values. The equipment bonding conductor sizes shown are specified in CSA C68.397
(R2001) and are based on the requirements of Table 16 and on the ampacities of Table 2 of the CE Code.
Ensure that only nonmagnetic connectors, locknuts and ground bushings are used.

19

1C TECK 90 (XLPE) Minus 40C

8 kV 133% Insulation Level

with Concentric Bonding Conductor


Conductor Size
Power AWG Bonding
or kcmil
AWG

*Aluminum Armour Only

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour*
lb/kft
kg/km

Copper
Content
kg/km

6
4

8
6

0.140
0.140

3.56
3.56

0.060
0.060

1.52
1.52

0.796
0.841

20.22
21.35

1.071
1.116

27.20
28.35

1.180
1.225

29.97
31.12

587
697

873
1037

210
330

3
2
1

6
6
4

0.140
0.140
0.140

3.56
3.56
3.56

0.060
0.060
0.060

1.52
1.52
1.52

0.866
0.896
0.928

21.99
22.76
23.58

1.141
1.171
1.203

28.98
29.74
30.56

1.250
1.280
1.312

31.75
32.51
33.32

748
811
934

1113
1207
1390

382
446
599

1/0
2/0
3/0
4/0

4
4
3
3

0.140
0.140
0.140
0.140

3.56
3.56
3.56
3.56

0.060
0.080
0.080
0.080

1.52
2.03
2.03
2.03

0.965
1.047
1.115
1.168

24.52
26.59
28.33
29.66

1.240
1.322
1.390
1.433

31.50
33.58
35.31
36.40

1.349
1.431
1.499
1.552

34.26
36.35
38.07
39.42

1029
1189
1382
1555

1531
1769
2057
2314

701
830
1051
1257

250
300
350

2
2
1

0.140
0.140
0.140

3.56
3.56
3.56

0.080
0.080
0.080

2.03
2.03
2.03

1.224
1.275
1.348

31.10
32.38
34.23

1.499
1.550
1.623

38.07
39.37
41.22

1.608
1.679
1.752

40.84
42.65
44.50

1764
1956
2252

2625
2911
3351

1500
1733
2062

400
500

1
1/0

0.140
0.140

3.56
3.56

0.080
0.080

2.03
2.03

1.391
1.493

35.33
37.91

1.666
1.768

42.32
44.91

1.795
1.879

45.59
48.18

2443
2909

3635
4329

2299
2864

600
1/0
0.140
3.56
0.080
2.03
1.587
750
2/0
0.140
3.56
0.080
2.03
1.721
1000
2/0
0.140
3.56
0.080
2.03
1.870
*Steel armour is not permitted in single conductor cable.

40.30
43.71
47.50

1.937
2.071
2.220

49.20
52.60
56.39

2.071
2.205
2.354

52.60
56.00
59.79

3432
4121
5033

5107
6132
7497

3332
4189
5359

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Ampacity**
40C
Ambient A

Appleton

T&B

Fittings
Commander

CrouseHinds

6
4

8
6

112
148

TMC118100
TMC118100

10469AL/ST100-469
10469AL/ST100-469

TCA-100-135
TCA-100-135

ST100-469
ST100-469

3
2
1

6
6
4

170
195
225

TMC140125
TMC140125
TMC140125

10469AL/ST100-469
10469AL/ST100-469
10469AL/ST100-469

TCA-100-135
TCA-100-135
TCA-100-135

ST100-469
ST100-469
ST100-469

1/0
2/0
3/0
4/0

4
4
3
3

260
299
345
400

TMC140125
TMC140125
TMC166150
TMC166150

10469AL/ST100-469
10470AL/ST125-470
10470AL/ST125-470
10550AL/ST125-550

TCA-125-151
TCA-125-151
TCA-125-151
TCA-125-167

ST100-469
ST125-470
ST125-470
ST125-550

250
300
350

2
2
1

444
500
549

TMC166150
TMC166150
TMC206200

10550AL/ST125-550
10471AL/ST125-471
10471AL/ST125-471

TCA-125-167
TCA-125-182
TCA-125-182

ST125-550
ST125-471
ST125-471

400
500

1
1/0

587
688

TMC206200
TMC206200

10472AL/ST150-472
10472AL/ST150-472

TCA-150-192
TCA-150-208

ST150-472
ST150-472

600
1/0
766
TMC206200
10473AL/ST150-473
TCA-150-208
ST150-473
750
2/0
889
TMC251250
10474AL/ST200-474
TCA-200-231
ST200-474
1000
2/0
1061
TMC251250
10475AL/ST200-475
TCA-200-250
ST200-475
**Per ICEA Publication P-46-426 for 90C conductor, 40C ambient air, cables spaced at least one diameter
apart in free air. Other conditions may require derating. Inspection authority agreement is required to use
these values. The equipment bonding conductor sizes shown are specified in CSA C68.397 (R2001) and are
based on the requirements of Table 16 and on the ampacities of the CE Code.
Ensure that only nonmagnetic connectors, locknuts and ground bushings are used.

20

3C TECK 90 (XLPE) Minus 40C

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

8 kV 100% Insulation Level

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour*
lb/kft
kg/km

Copper
Content
kg/km

6
4

8
8

0.115
0.115

2.92
2.92

0.080
0.080

2.03
2.03

1.324
1.420

33.64
36.07

1.599
1.695

40.61
43.05

1.728
1.824

43.89
46.33

1277
1546

1900
2301

446
665

3
2
1

6
6
6

0.115
0.115
0.115

2.92
2.92
2.92

0.080
0.080
0.080

2.03
2.03
2.03

1.474
1.539
1.613

37.45
39.10
40.97

1.749
1.859
1.963

44.42
47.22
49.86

1.875
2.023
2.097

47.63
51.38
53.26

1734
1926
2296

2580
2866
3417

866
1057
1304

1/0
2/0
3/0
4/0

6
6
4
4

0.115
0.115
0.115
0.115

2.92
2.92
2.92
2.92

0.080
0.080
0.080
0.110

2.03
2.03
2.03
2.79

1.693
1.778
1.880
2.053

43.01
45.16
47.75
52.14

2.043
2.128
2.230
2.403

51.89
54.05
56.64
61.03

2.177
2.262
2.364
2.537

55.30
57.45
60.04
64.44

2586
2952
3439
4111

3848
4393
5117
6118

1609
1997
2558
3173

250
300
350

4
4
3

0.115
0.115
0.115

2.92
2.92
2.92

0.110
0.110
0.110

2.79
2.79
2.79

2.179
2.288
2.388

55.35
58.11
60.65

2.529
2.638
2.738

64.24
67.00
69.54

2.663
2.772
2.872

67.64
70.41
72.95

4704
5305
5938

7000
7894
8836

3716
4414
5171

400
500

3
3

0.115
0.115

2.92
2.92

0.110
0.110

2.79
2.79

2.481
2.700

63.02
68.58

2.831
3.050

71.91
77.47

2.965
3.184

75.31
80.87

6530
7777

9717
11573

5883
7278

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Ampacity**
40C
Ambient A

Appleton

Fittings
T&B

Commander

CrouseHinds

6
4

8
8

93
122

TMC166150
TMC206200

10471/ST125-471
10472/ST150-472

TCA-125-182
TCA-150-192

ST125-471
ST150-472

3
2
1

6
6
6

139
159
184

TMC206200
TMC206200
TMC206200

10472/ST150-472
10473/ST150-473
10551/ST200-551

TCA-150-192
TCA-150-208
TCA-200-231

ST150-472
ST150-473
ST200-551

1/0
2/0
3/0
4/0

6
6
4
4

211
243
279
321

TMC251250
TMC251250
TMC251250
TMC251250

10551/ST200-474
10474/ST200-474
10475/ST200-475
10553/ST250-477

TCA-200-231
TCA-200-231
TCA-200-250
TCA-250-268

ST200-474
ST200-474
ST200-475
ST250-477

250
300
350

4
4
3

355
398
435

TMC304300
TMC304300
TMC304300

10553/ST250-478
10477/ST250-478
10477/ST300-479

TCA-250-268
TCA-250-284
TCA-250-300

ST250-478
ST250-478
ST300-479

400
3
461
TMC304300
10554/ST300-479
TCA-250-300
ST300-479
500
3
536
TMC359350
10555/ST300-480
TCA-300-322
ST300-480
**Per ICEA Publication P-46-426 for 90C conductor, 40C ambient air, cables spaced at
least one diameter apart in free air. Other conditions may require derating. Inspection
authority agreement is required to use these values. The equipment bonding conductor sizes
shown are specified in CSA C68.397 (R2001) and are based on the requirements of Table
16 and on the ampacities of Table 2 of the CE Code.

21

3C TECK 90 (XLPE) Minus 40C

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Insulation
Thickness
inches
mm

8 kV 133% Insulation Level

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour
lb/kft
kg/km

Copper
Content
kg/km

6
4

8
8

0.140
0.140

3.56
3.56

0.080
0.080

2.03
2.03

1.434
1.529

36.42
38.84

1.709
1.849

43.41
46.96

1.838
2.013

46.68
51.13

1433
1677

2132
2496

446
665

3
2
1

6
6
6

0.140
0.140
0.140

3.56
3.56
3.56

0.080
0.080
0.080

2.03
2.03
2.03

1.588
1.653
1.722

40.32
41.98
43.74

1.938
2.003
2.072

49.23
50.88
52.63

2.072
2.137
2.206

52.62
54.28
56.03

2001
2203
2459

2977
3278
3659

866
1057
1304

1/0
2/0
3/0
4/0

6
6
4
4

0.140
0.140
0.140
0.140

3.56
3.56
3.56
3.56

0.080
0.080
0.110
0.110

2.03
2.03
2.79
2.79

1.802
1.887
2.049
2.166

45.78
47.93
52.05
55.02

2.152
2.237
2.399
2.516

54.66
56.82
60.93
63.91

2.286
2.371
2.533
2.650

58.06
60.22
64.34
67.31

2754
3111
3740
4365

4098
4629
5565
6496

1609
1997
2558
3173

250
300
350

4
4
3

0.140
0.140
0.140

3.56
3.56
3.56

0.110
0.110
0.110

2.79
2.79
2.79

2.289
2.397
2.497

58.13
60.89
63.42

2.639
2.747
2.847

67.03
69.77
72.31

2.773
2.881
2.981

70.43
73.18
75.72

4895
5501
6138

7284
8186
9134

3716
4414
5171

400
500

3
3

0.140
0.140

3.56
3.56

0.110
0.110

2.79
2.79

2.590
2.809

65.79
71.35

2.940
3.159

74.68
80.24

3.074
3.293

78.08
83.64

6737
7997

10025
11900

5883
7278

Conductor Size
Power AWG Bonding
or kcmil
AWG

Ampacity**
40C
Ambient A

Appleton

Fittings
T&B

Commander

CrouseHinds

6
4

8
8

93
122

TMC206200
TMC206200

10472/ST150-472
10473/ST150-473

TCA-150-192
TCA-150-208

ST150-472
ST150-473

3
2
1

6
6
6

139
159
184

TMC206200
TMC206200
TMC251250

10473/ST200-551
10551/ST200-551
10474/ST200-474

TCA-200-231
TCA-200-231
TCA-200-231

ST200-551
ST200-551
ST200-474

1/0
2/0
3/0
4/0

6
6
4
4

211
243
279
321

TMC251250
TMC251250
TMC251250
TMC304300

10474/ST200-474
10475/ST200-475
10476/ST250-477
10553/ST250-478

TCA-200-231
TCA-200-250
TCA-250-268
TCA-250-268

ST200-474
ST200-475
ST250-477
ST250-478

250
300
350

4
4
3

355
398
435

TMC304300
TMC304300
TMC304300

10477/ST250-478
10477/ST300-479
10554/ST300-479

TCA-250-284
TCA-250-300
TCA-300-322

ST250-478
ST300-479
ST300-479

400
3
461
TMC304300
10554/ST300-480
TCA-300-322
ST300-480
500
3
536
TMC359350
10479/ST300-481
TCA-300-344
ST300-481
**Per ICEA Publication P-46-426 for 90C conductor, 40C ambient air, cables spaced at
least one diameter apart in free air. Other conditions may require derating. Inspection
authority agreement is required to use these values. The equipment bonding conductor
sizes shown are specified in CSA C68.397 (R2001) and are based on the requirements of
Table 16 and on the ampacities of Table 2 of the CE Code.

22

1C TECK 90 (XLPE) Minus 40C

15 kV 100% Insulation Level

with Concentric Bonding Conductor


Conductor Size
Power AWG Bonding
or kcmil
AWG

*Aluminum Armour Only

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour*
lb/kft
kg/km

Copper
Content
kg/km

2
1

6
4

0.175
0.175

4.45
4.45

0.060
0.080

1.52
2.03

0.967
1.041

24.56
26.45

1.242
1.316

31.55
33.43

1.351
1.425

34.32
36.20

868
1043

1292
1552

446
599

1/0
2/0
3/0
4/0

4
4
3
3

0.175
0.175
0.175
0.175

4.45
4.45
4.45
4.45

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

1.078
1.118
1.186
1.239

27.39
28.39
30.13
31.46

1.353
1.393
1.461
1.514

34.37
35.38
37.11
38.46

1.462
1.502
1.570
1.643

37.13
38.15
39.88
41.73

1138
1254
1446
1623

1693
1867
2152
2415

701
830
1051
1257

250
300
350

2
2
1

0.175
0.175
0.175

4.45
4.45
4.45

0.080
0.080
0.080

2.03
2.03
2.03

1.295
1.346
1.443

32.90
34.18
36.64

1.570
1.621
1.718

39.88
41.71
43.64

1.699
1.750
1.847

43.15
44.45
46.91

1823
2047
2342

2713
3046
3485

1500
1733
2062

400
500

1
1/0

0.175
0.175

4.45
4.45

0.080
0.080

2.03
2.03

1.486
1.567

37.74
39.81

1.761
1.917

44.73
48.69

1.890
2.051

48.01
52.10

2534
3102

3771
4616

2299
2864

600
1/0
0.175
4.45
0.080
2.03
1.658
750
2/0
0.175
4.45
0.080
2.03
1.792
1000
2/0
0.175
4.45
0.110
2.79
2.001
*Steel armour is not permitted in single conductor cable.

42.10
45.51
50.82

2.008
2.142
2.351

51.00
54.41
59.72

2.142
2.276
2.485

54.41
57.81
63.12

3498
4185
5225

5205
6228
7775

3332
4189
5359

Conductor Size
Power AWG Bonding
or kcmil
AWG

Ampacity**
40C
Ambient A

Appleton

T&B

Fittings
Commander

CrouseHinds

2
1

6
4

195
225

TMC140125
TMC140125

10470AL/ST125-470
10470AL/ST125-470

TCA-125-151
TCA-125-151

ST125-470
ST125-470

1/0
2/0
3/0
4/0

4
4
3
3

259
298
343
397

TMC140125
TMC166150
TMC166150
TMC166150

10470AL/ST125-470
10470AL/ST125-470
10550AL/ST125-550
10471AL/ST125-471

TCA-125-151
TCA-125-167
TCA-125-167
TCA-125-167

ST125-470
ST125-470
ST125-550
ST125-471

250
300
350

2
2
1

440
496
543

TMC166150
TMC206200
TMC206200

10471AL/ST125-471
10471AL/ST125-471
10472AL/ST150-472

TCA-125-182
TCA-125-182
TCA-150-192

ST125-471
ST125-471
ST150-472

400
500

1
1/0

580
678

TMC206200
TMC206200

10472AL/ST150-472
10473AL/ST150-473

TCA-150-192
TCA-150-208

ST150-472
ST150-473

600
1/0
753
TMC251250
10474AL/ST200-474
TCA-200-231
ST200-474
750
2/0
872
TMC251250
10474AL/ST200-474
TCA-200-231
ST200-474
1000
2/0
1040
TMC251250
10552AL/ST200-475
TCA-200-250
ST200-475
**Per ICEA Publication P-46-426 for 90C conductor, 40C ambient air, cables spaced at
least one diameter apart in free air. Other conditions may require derating. Inspection
authority agreement is required to use these values. The equipment bonding conductor
sizes shown are specified in CSA C68.397 (R2001) and are based on the requirements of
Table 16 and on the ampacities of Table 2 of the CE Code.
Ensure that only nonmagnetic connectors, locknuts and ground bushings are used.

23

1C TECK 90 (XLPE) Minus 40C

15 kV 133% Insulation Level

with Concentric Bonding Conductor


Conductor Size
Power AWG
Bonding
or kcmil
AWG

*Aluminum Armour Only

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour*
lb/kft
kg/km

Copper
Content
kg/km

0.220

5.59

0.080

2.03

1.132

28.76

1.407

35.74

1.516

38.51

1133

1686

599

1/0
2/0
3/0
4/0

4
4
3
3

0.220
0.220
0.220
0.220

5.59
5.59
5.59
5.59

0.080
0.080
0.080
0.080

2.03
2.03
2.03
2.03

1.170
1.209
1.277
1.330

29.71
30.71
32.45
33.78

1.445
1.484
1.552
1.605

36.71
37.69
39.42
40.77

1.554
1.593
1.681
1.734

39.47
40.46
42.70
44.04

1232
1349
1545
1755

1833
2007
2299
2612

701
830
1051
1257

250
300
350

2
2
1

0.220
0.220
0.220

5.59
5.59
5.59

0.080
0.080
0.080

2.03
2.03
2.03

1.387
1.461
1.534

35.22
37.11
38.96

1.662
1.736
1.854

42.21
44.09
47.09

1.791
1.865
2.018

45.49
47.37
51.26

1960
2187
2456

2917
3254
3655

1500
1733
2062

400
500

1
1/0

0.220
0.220

5.59
5.59

0.080
0.080

2.03
2.03

1.581
1.659

40.16
42.13

1.931
2.009

49.05
51.03

2.065
2.143

52.45
54.43

2784
3230

4143
4807

2299
2864

600
1/0
0.220
5.59
0.080
2.03
1.754
750
2/0
0.220
5.59
0.110
2.79
1.943
1000
2/0
0.220
5.59
0.110
2.79
2.120
*Steel armour is not permitted in single conductor cable.

44.55
49.35
53.85

2.104
2.293
2.470

53.44
58.24
62.74

2.238
2.427
2.604

56.85
61.65
66.14

3649
4453
5494

5430
6626
8176

3332
4189
5359

Conductor Size
Power AWG Bonding
or kcmil
AWG

Ampacity**
40C
Ambient A

Appleton

T&B

Fittings
Commander

CrouseHinds

225

TMC-166150

10470AL/ST125-470

TCA-125-167

ST125-470

1/0
2/0
3/0
4/0

4
4
3
3

259
298
343
397

TMC-166150
TMC-166150
TMC-166150
TMC-206200

10550AL/ST125-550
10550AL/ST125-550
10471AL/ST125-471
10471AL/ST125-471

TCA-125-167
TCA-125-167
TCA-125-182
TCA-125-182

ST125-550
ST125-550
ST125-471
ST125-471

250
300
350

2
2
1

440
496
543

TMC-206200
TMC-206200
TMC-206200

10472AL/ST150-472
10472AL/ST150-472
10473AL/ST150-473

TCA-150-192
TCA-150-192
TCA-150-208

ST150-472
ST150-472
ST150-473

400
500

1
1/0

580
678

TMC-206200
TMC-251250

10473AL/ST200-551
10551AL/ST200-474

TCA-200-231
TCA-200-231

ST200-551
ST200-474

600
1/0
753
TMC-251250
10474AL/ST200-474
TCA-200-231
ST200-474
750
2/0
872
TMC-251250
10475AL/ST200-475
TCA-200-250
ST200-475
1000
2/0
1040
TMC-251250
10553AL/ST250-477
TCA-250-268
ST250-477
**Per ICEA Publication P-46-426 for 90C conductor, 40C ambient air, cables spaced at
least one diameter apart in free air. Other conditions may require derating. Inspection
authority agreement is required to use these values. The equipment bonding conductor
sizes shown are specified in CSA C68.397 (R2001) and are based on the requirements of
Table 16 and on Table 2 of the ampacities of the CE Code.
Ensure that only nonmagnetic connectors, locknuts and ground bushings are used.

24

3C TECK 90 (XLPE) Minus 40C

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

15 kV 100% Insulation Level

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour*
lb/kft
kg/km

Copper
Content
kg/km

2
1

6
6

0.175
0.175

4.45
4.45

0.080
0.080

2.03
2.03

1.806
1.875

45.86
47.63

2.156
2.225

54.76
56.52

2.290
2.359

58.17
59.92

2424
2673

3607
3978

1057
1304

1/0
2/0
3/0
4/0

6
6
4
4

0.175
0.175
0.175
0.175

4.45
4.45
4.45
4.45

0.080
0.110
0.110
0.110

2.03
2.79
2.79
2.79

1.955
2.104
2.206
2.319

49.67
53.44
56.03
58.90

2.305
2.454
2.556
2.669

58.55
62.33
64.92
67.79

2.479
2.588
2.690
2.803

62.97
65.74
68.33
71.20

2972
3545
4054
4615

4423
5275
6032
6868

1609
1997
2558
3173

250
300
350

4
4
3

0.175
0.175
0.175

4.45
4.45
4.45

0.110
0.110
0.110

2.79
2.79
2.79

2.441
2.550
2.702

62.01
64.77
68.62

2.791
2.900
3.052

70.89
73.66
77.52

2.925
3.034
3.186

74.30
77.06
80.92

5154
5768
6512

7670
8584
9691

3716
4414
5171

400
500

3
3

0.175
0.175

4.45
4.45

0.110
0.110

2.79
2.79

2.795
2.962

70.99
75.24

3.145
3.312

79.88
84.12

3.279
3.446

83.29
87.53

7119
8354

10594
12432

5883
7278

Conductor Size
Power AWG Bonding
or kcmil
AWG

Ampacity**
40C
Ambient A

Appleton

Fittings
T&B

Commander

CrouseHinds

2
1

6
6

164
187

TMC-251250
TMC-251250

10474/ST200-474
10475/ST200-475

TCA-200-250
TCA-200-250

ST200-474
ST200-475

1/0
2/0
3/0
4/0

6
6
4
4

215
246
283
325

TMC-251250
TMC-251250
TMC-304300
TMC-304300

10475/ST200-475
10553/ST250-477
10553/ST250-478
10447/ST300-479

TCA-250-268
TCA-250-268
TCA-250-284
TCA-250-284

ST200-475
ST250-477
ST250-478
ST300-479

250
300
350

4
4
3

359
399
438

TMC-304300
TMC-304300
TMC-359350

NA/ST300-479
10554/ST300-480
10555/ST300-480

TCA-250-300
TCA-300-322
TCA-300-322

ST300-479
ST300-480
ST300-480

400
3
470
TMC-359350
10479/ST300-481 TCA-300-344
ST300-481
500
3
536
TMC-359350
10480/ST350-482 TCA-300-365
ST350-482
**Per ICEA Publication P-46-426 for 90C conductor, 40C ambient air, cables spaced at
least one diameter apart in free air. Other conditions may require derating. Inspection
authority agreement is required to use these values. The equipment bonding conductor
sizes shown are specified in CSA C68.397 (R2001) and are based on the requirements of
Table 16 and on the ampacities of Table 2 of the CE Code.

25

3C TECK 90 (XLPE) Minus 40C

Conductor Size
Power AWG
Bonding
or kcmil
AWG

Insulation
Thickness
inches
mm

Inner Jacket
Thickness
inches
mm

15 kV 133% Insulation Level

Inner Jacket
inches
mm

Approximate Diameters
Armour
inches
mm

Outer Covering
inches
mm

Approximate Weight
Aluminum Armour*
lb/kft
kg/km

Copper
Content
kg/km

0.220

5.59

0.110

2.79

2.136

54.25

2.486

63.14

2.620

66.55

3116

4740

1304

1/0
2/0
3/0
4/0

6
6
4
4

0.220
0.220
0.220
0.220

5.59
5.59
5.59
5.59

0.110
0.110
0.110
0.110

2.79
2.79
2.79
2.79

2.216
2.301
2.403
2.516

56.29
58.44
61.03
63.90

2.566
2.651
2.753
2.866

65.18
67.34
69.93
72.80

2.700
2.785
2.887
3.000

68.58
70.74
73.33
76.20

3503
3880
4400
4973

5213
5774
6548
7400

1609
1997
2558
3173

250
300
350

4
4
3

0.220
0.220
0.220

5.59
5.59
5.59

0.110
0.110
0.110

2.79
2.79
2.79

2.638
2.798
2.898

67.01
71.08
73.62

2.988
3.148
3.248

75.89
79.96
82.50

3.122
3.282
3.382

79.29
83.36
85.90

5524
6252
6972

8220
9304
10375

3716
4414
5171

400
500

3
3

0.220
0.220

5.59
5.59

0.110
0.140

2.79
3.56

2.992
3.225

75.99
81.91

3.342
3.575

84.89
90.81

3.476
3.709

88.29
94.21

7590
8988

11295
13375

5883
7278

Conductor Size
Power AWG Bonding
or kcmil
AWG

Ampacity**
40C
Ambient A

Appleton

T&B

Fittings
Commander

CrouseHinds

187

TMC-304300

10553/ST250-478

TCA-250-284

ST250-478

1/0
2/0
3/0
4/0

6
6
4
4

215
246
283
325

TMC-304300
TMC-304300
TMC-304300
TMC-304300

10553/ST250-478
10477/ST250-478
10477/ST300-479
10544/ST300-480

TCA-250-284
TCA-250-284
TCA-250-300
TCA-300-322

ST250-478
ST250-478
ST300-479
ST300-480

250
300
350

4
4
3

359
399
438

TMC-304300
TMC-359350
TMC-359350

10555/ST300-480
10479/ST300-481
10480/ST300-481

TCA-300-322
TCA-300-344
TCA-300-344

ST300-480
ST300-481
ST300-481

400
3
470
TMC-359350
10481/ST350-482
TCA-300-365
ST350-482
500
3
536
TMC-402400
10483/ST350-483
N/A
ST350-483
**Per ICEA Publication P-46-426 for 90C conductor, 40C ambient air, cables spaced at
least one diameter apart in free air. Other conditions may require derating. Inspection
authority agreement is required to use these values. The equipment bonding conductor
sizes shown are specified in CSA C68.397 (R2001) and are based on the requirements of
Table 16 and on the ampacities of Table 2 of the CE Code.

26

Installation and Technical Data


AMPACITY CORRECTION FACTORS
Conductor Temperature
l = l
where

Tc Ta
t + 90
x c
90 Ta tc + Tc
l = current at conductor temperature Tc
l = current at conductor temperature 90C
Ta = ambient temperature
Tc = desired conductor temperature
tc = inferred temperature of zero resistance
(Cu: tc = 234.5, Al : tc = 228.1)

Ambient Temperature
l = l
where

l =
l =
Tc =
Ta =
Ta =

Tc Ta
Tc Ta
current at ambient Ta
current at tabulated ambient Ta
conductor temperature
tabulated ambient temperature
new ambient temperature

For certain temperature changes, the multiplying factor becomes:

Conductor
Temperature, C
90
80
70
60

Ambient Air Temperature


30C
40C
1.09
1.02
0.92
0.81

1.00
0.91
0.80
0.66

27

Installation and Technical Data


ELECTRICAL CHARACTERISTICS
Resistance
Conductor dc resistance is given in the Stranded Bare Copper and Aluminum
Conductor Information on page 39. These values are at 25C and can be
corrected to other temperatures from the following:

Temperature
C

Correction
Factor

Temperature
C

Correction
Factor

0
10
20
30
40
50

0.90
0.94
0.98
1.02
1.06
1.10

60
70
75
80
90
130

1.14
1.18
1.20
1.22
1.26
1.41

The increase in conductor resistance due to skin effect can be calculated from the
factor (1 + Ys) where
0.1508 2
R
Ys =
at 60 Hz
0.1508 2
192 + 0.8
R

(
(

)
)

(R = dc resistance in /km at desired conductor temperature)


Where desired, the additional effect of proximity can be determined from the
factor (1+ Yp) where
YP = Ys
where

dc
s
Ys
Yp

( )[

=
=
=
=

dc
s

0.312

()
dc
s

1.18
at 60 Hz
ys + 0.27

conductor diameter, mm
equivalent axial distance between conductor centres, mm
skin effect co-efficient
proximity effect co-efficient

Approximate AC/DC Ratios for Conductors at 90C


Size

1
1/0
2/0
3/0
4/0
250
350
500
750
1000

28

Copper
Single
Conductor

Multi
Conductor

1.000
1.001
1.001
1.002
1.003
1.004
1.007
1.015
1.033
1.057

1.010
1.020
1.030
1.040
1.050
1.060
1.080
1.130
1.210
1.360

Aluminum
Single
Multi
Conductor
Conductor
1.000
1.000
1.000
1.001
1.001
1.001
1.003
1.006
1.012
1.022

1.010
1.010
1.010
1.010
1.010
1.020
1.030
1.060
1.120
1.190

Installation and Technical Data


Inductive Reactance
The inductive reactance of cables in a multicable circuit is:

( )

GMD
XL = 0.0754 ln GMR /km to neutral at 60 Hz
where

GMD = equivalent axial spacing or axial distance between the phase


conductors in the circuit in mm
GMR = geometric mean radius of the phase conductor. For compact
round conductors GMR = 0.38 conductor diameter. (See Stranded
Bare Copper and Aluminum Conductor Information.)

Capacitive Reactance
Capacitive reactance is calculated from capacitance:
Xc =

1 = 2650 km at 60 Hz
2fC
C

where C = capacitance in F/km


For single conductor insulated, and shielded cables with outer metallic layer:
C = 0.0556 F/km
ln (D/d)
= dielectric constant of insulation (= 2.3 for XLPE)
D = diameter over cable dielectric
d = diameter under cable dielectric
Note: Capacitive reactance can normally be neglected for open lines up to
about 40 km or in cables up to 20 km in length.

where

Charging Current
Charging current is calculated from capacitance and voltage as follows:
lch = 2fCE = 377 CE mA/km at 60 Hz
where

C = capacitance in F/km (see above)


E = line to neutral voltage in kV

Voltage Drop
For multi conductor cables and single conductor cables at close spacing, voltage
drop may be determined by use of the method shown in the following pages.
Where necessary to calculate for single conductors spaced apart, the following
formula will give sufficiently accurate results:
Es Er = l (R cos + XL sin) V/km to neutral
where

Es
Er
l
R
XL

=
=
=
=
=
=

sending end voltage, V


receiving end voltage, V
current A
resistance of conductor, /km
inductive reactance of conductors, /km
load power factor angle (NB: 100 cos = % load power factor)

It is important, when determining limiting voltage drops, that the correct voltage
is used, i.e. line-to-line, or line-to-neutral.

29

Installation and Technical Data


Voltage Drop
The voltage drop curves contained in this publication are applicable to aluminum
armoured TECK cables. For steel armoured TECK cables, increase the values
obtained from the curves by 20% to estimate the voltage drop.
In the table for 3 phase 60Hz Voltage Drop Single Conductor TECK are curves of
voltage drop for single and 3 conductor cables with copper conductors, 3 phase,
60 cycles. The voltage drop for 4 conductor cables, such as in a 3 phase, 4 wire
grounded neutral system, may be taken from the curve for a 3 conductor cable,
where the fourth conductor carries only unbalance current of a 3 phase system.
The voltage drop curves are generated using the following formula:
Voltage Drop = Rcos + XLsin (volts/amp-km)
where:

R = AC resistance (ohms/km)
XL = inductive reactance (ohms/km)
= load power factor angle
(NB: 100cos = % load power factor)

To calculate the net voltage drop for a specific application, the following formula
must be used to account for systems other than 3 phase, circuit length and current:
Net Voltage Drop = f x K x I x L
Net Voltage Drop = 1000
where:

f
K
I
L

=
=
=
=

system correction factor (see below)


voltage drop factor from curve (v/amps-km)
current carried by one conductor (amps)
circuit length (meters)

Since the curves are based on a 3 phase line-to-neutral system, the following
correction factor (f) must be used in the voltage drop calculation:

System
1
1
1
3
3
3

phase,
phase,
phase,
phase,
phase,
phase,

Correction Factor (f)


2 wire (120 V branch circuits)
3 wire (240 V residential circuits)
3 wire line-to-line
3 wire line-to-line
4 wire line-to-line
4 wire line-to-neutral

2
2
2
1.73
1.73
1

The following examples illustrate the proper use of the voltage drop formula and
factors:

Example 1
Find the voltage drop and percent drop given the following:
3 phase circuit at 600/347 volts,
length of circuit 250 meters,
conductor single conductor TECK, size 250 kcmil, in air with one diameter
spacing,
load 200 amps at 90% load power factor.

30

Installation and Technical Data


SOLUTION

Find the K factor from the single conductor TECK Voltage Drop Curve; for 250
kcmil conductor at 90% Load Factor we get:
K = 0.250 volts per 1000 amp meters
therefore, from the voltage drop formula we calculate the voltage drop as:
Voltage Drop = 1 x 0.250 x 200 x 250
1000
Voltage Drop = 12.5 volts
or
Voltage Drop = 12.5 x 100%
Voltage Drop = 347
Voltage Drop = 3.6%

Example 2
Consider the above example with a three-conductor TECK and the same
conditions.
SOLUTION

Find the K factor from the three conductor TECK Voltage Drop Curve; for 250
kcmil conductor at 90% Load Factor we get:
K = 0.195 volts per 1000 amp meters
therefore, from the voltage drop formula we calculate the voltage drop as:
Voltage Drop = 1 x 0.195 x 200 x 250
1000
Voltage Drop = 9.75 volts
or
Voltage Drop = 9.75 x 100%
Voltage Drop = 347
Voltage Drop = 2.8%

31

Installation and Technical Data


3 phase 60 Hz Voltage Drop
Single Copper Conductor TECK
One cable diameter spacing No circulating current in concentric ground
wires

32

Installation and Technical Data


3 phase 60 Hz Voltage Drop
Three Copper Conductor TECK

33

Installation and Technical Data


TECK Short circuit Capacity XLPE Insulated Copper Conductors

Short circuit Calculations


The short circuit capabilities of the conductors of a cable for a given duration
depend principally on their heat capacities, and are limited by the maximum
temperature permitted under short-circuit conditions. The temperature limits
established by Nexans are as follows:
250C at phase conductor
200C at shield or concentric bonding conductor
The following graph provides a means of estimating the short circuit capacity of
copper XLPE or TRXLPE Insulated conductors. These curves are plotted for
durations in cycles (60 Hz basis). Logarithmic interpolation will provide values for
intermediate durations. The curves may also be used to determine the amount of
conducting material required for a known short-circuit condition.
It is important to limit short circuit durations to no more than 2 or 3 seconds as no
heat flow is taken into account in the functions used to calculate these curves.

34

Installation and Technical Data


TECK Short circuit Capacity
XLPE Insulated Copper Conductors

35

Installation and Technical Data


INSTALLATION DATA
Pulling Tension Limits
It is recommended that FIREX -II TECK Cables be pulled on the conductors using
a pulling eye where necessary. The maximum permissible tension is 8 lbf/kcmil
(=10,000 lbf/in2) for single conductor cables. For three conductor cables
recommended maximum pulling tension is 16 lbf/kcmil based on the area of one
conductor only. To avoid displacing the armour it may be necessary to use a
basket grip over the outer jacket as well as the pulling eye. The use of guide
rollers or other friction-reducing devices is highly recommended.
Low-temperature Installation
Nexans FIREX -II TECK Cables meet CSA cold bend and impact requirements at
minus 40C. These tests are conducted under carefully controlled laboratory
conditions to ensure comparability of results from different laboratories.
Since actual field conditions are not subject to such control it is recommended
that, wherever possible, provision be made for the heating of cables to at least
minus 10C until the actual cable installation. This will minimize the risk of
damaging cables in very cold weather.
Vertical Installation
For vertical installations, the use of a messenger may be necessary to support the
cable during installation. Offsets may well be necessary for final positioning of
the cable. Please consult your nearest Nexans Sales Office for recommendations
and information on Vertex cable.
Bending Radius
Nexans FIREX -II TECK Cables are flexible and can be trained easily. The
following table gives minimum bending radius factors for final training. During
installation, and especially while pulling, bending radii should be twice the values
shown below:
Up to 5 kV
(Unshielded)
Over 5 kV and all
metal tape shielded
cable

7 x Outside Diameter

12 x Outside Diameter

Note: The bending radius is that of the inner surface of the cable at the bend.
In all cases these values are for permanent training after installation. Larger radii
are recommended wherever the cable is being pulled under tension, preferably not
less than twice and in no case less than 1.5 times the values for permanent
training.

36

Installation and Technical Data


Pulling Tension Calculations
The maximum pulling tension on a cable should not exceed:
a) where pulled by means of the conductor(s)
70nA newtons (N) for copper
50nA N for aluminum
where n = 1 for single conductor cable
1.5 for 2C cable
2 for 3C cable and for triplexed 1C cables
A = cross-section of one conductor (mm2)
b) where pulled by means of a basket grip over an outer jacket or
concentric wires 5000 N or value from (a) above, whichever is the lower.
The tension resulting from a given duct installation is calculated as follows:
a) T = 9.8 LWf (for a straight section)
where T = pulling tension, N
L = length of duct section, m
W = linear mass of cable, kg/m
f = coefficient of friction, typically 0.35
b) T = T2 + T1efa (for a duct with a bend)
where T 2 = tension for the straight section following the bend
(calculated as in (a) above)
T 1 = tension for the straight section preceding the bend
e = 2.71828
f = coefficient of friction
a = angle of bend, radians
efa is evaluated for some common conditions:

efa
bend angle

f = 0.3

f = 0.35

f = 0.4

30
45
60
90

1.17
1.27
1.37
1.60

1.20
1.32
1.44
1.73

1.23
1.37
1.52
1.88

At any bend the tension should not exceed 3600 N/m of radius of the bend in
order to avoid excessive compression forces in the cable.

Assuming the illustrated duct layout and:


triplexed 3 x 1/c 500 kcmil copper 15 kV cable
linear mass = 11.0 kg/m
f = 0.35
pulling from A to F
Tension at B (T1) = 9.8 x 60 x 11.0 x 0.35 = 2270 N
Tension at C (T2) = T1efa = 2270 x 1.32 = 3000 N
Tension at D (T3) = 3000 + (9.8 x 20 x 11.0 x 0.35) = 3755 N
Tension at E (T4) = T3efa = 3755 x 1.73 = 6500 N
Tension at F (T5) = 6500 + (9.8 x 30 x 11.0 x 0.35) = 7630 N

37

Installation and Technical Data


The maximum permissible tension on this cable would be
70 x 2 x 253 = 35,420 N
The tension at E = 6500/3 = 2170 N/m of radius, which is not excessive;
however, it is prudent to reduce this value, if possible, by comparing the results if
the cable is pulled from F to A:
Tension at E (T1) = 9.8 x 30 x 11.0 x 0.35 = 1130 N
Tension at D (T2) = 1130 x 1.73 = 1960 N
Tension at C (T3) = 1960 + (9.8 x 20 x 11.0 x 0.35) = 2715 N
Tension at B (T4) = 2715 x 1.32 = 3580 N
Tension at A (T5) = 3580 + (9.8 x 60 x 11.0 x 0.35) = 5840 N
Pulling from F to A results in significantly lower tensions in the bends and overall,
and should be selected as the preferred direction of pulling.

Field Testing
Voltage tests after installation should
be made as soon as possible. Before
applying the test voltage, ensure that
all equipment is disconnected from the
cable circuit. Also ensure that there is
sufficient clearance between the cable
ends and any grounded surfaces,
objects or persons. We recommend
that only qualified persons familiar
with the process and associated safety
precautions perform a D.C. Hipot test.
For all 5kV and higher shielded cable,
a high-voltage DC test made before
placing a new cable system in service
will normally reveal gross
imperfections such as mechanical
damage during installation or
improperly made accessories. It is not
expected to reveal deterioration due to
ageing in service.

At any time during installation, a Proof


Test may be made at a voltage not
exceeding that shown in the table
applied for five minutes.

These tests should only be undertaken


by persons familiar with the use of the
equipment and appropriate safety
precautions. If any equipment is
included beyond the cable
terminations, the dielectric strength of
such equipment must be taken into
consideration when establishing the
test voltage.

After installation and before the cable


is placed in regular service, an
Acceptance Test may be made at a
voltage not exceeding that shown in
the table applied for 15 consecutive
minutes.
After the cable has been completely
installed and placed in regular
service, a Maintenance Test may be
made at any time within the first five
years at a voltage not exceeding that
shown in the table applied for five
consecutive minutes. Recent research
has shown that the loss of dielectric
strength caused by normal wet aging
will shorten the cable life when

Cable
Voltage
Rating
kV

5
8
15

DC Proof Test
During Installation
(5 minute test)
kV
100%
133%
Insulation Insulation
Level
Level
25
34
53

25
41
60

*Within the guarantee period

38

subjected to DC testing. After that


time, such testing is not recommended.

For further information, see Nexans


Product Information Letter number PIL
14-12.
For 600, 1000 and 5000 volt nonshielded cables, a megger test at the
cables rated voltage is
recommended.

DC Test Voltage
Prior to Energization
(15 minute test)
kV
100%
133%
Insulation Insulation
Level
Level
28
36
56

28
44
64

DC Test Voltage
after cable has been in
service (5 minute test)*
kV
100%
133%
Insulation Insulation
Level
Level
9
11
18

9
14
20

Stranded Bare Copper and Aluminum Conductor


Information
Approximate Weight(c)

Nominal Conductor Diameter


Conductor
Size
AWG cmil

Area
mm2

sq. in.

No. of
Wires(a), (b)

Wire
Diameter
mm
in

Compressed
Round
mm
in

14
12
10

4110
6530
10380

2.08 0.00323
3.31 0.00513
5.26 0.00816

7
7
7

0.61 0.0242
0.77 0.0305
0.98 0.0385

1.80 0.071
2.26 0.089
2.87 0.113

8
6
4

16510
26240
41740

8.37 0.01297
13.30 0.02061
21.15 0.03278

7
7
7

1.23 0.0486
1.55 0.0612
1.96 0.0772

3.61 0.142
4.55 0.179
5.72 0.225

3
2
1

52620
66360
83690

26.66 0.04133
7
2.20 0.0867
33.63 0.05212
7
2.47 0.0974
42.41 0.06573 19(18)[18] 1.69 0.0664

1/0
2/0
3/0
4/0

105600
133100
167800
211600

Compact
Round
mm
in

Average D.C. Resistance(c) 25C

kg per 1000 m
Lbs per 1000 ft Ohms per 1000 m
Copper Aluminum Copper Aluminum Copper Aluminum

18.9
30.0
47.7

9.1
14.5

12.7
20.2
32.1

8.61
6.13 5.42
9.75 3.41

3.40 0.134
4.29 0.169
5.41 0.213

75.9
121
192

23.1
36.7
58.3

51.0
81.1
129

15.5
24.6
39.2

6.40 0.252
7.19 0.283
8.18 0.322

6.05 0.238
6.81 0.268
7.59 0.299

242
305
385

73.5
92.7
117

163
205
258

485
611
771
972

147
186
234
296

Ohms per 1000 ft


Copper Aluminum

8.89
5.59

2.63
1.65
1.04

2.71
1.70

2.14
1.35
0.848

3.52
2.21
1.39

0.653
0.411
0.258

1.07
0.674
0.424

49.4
62.3
78.6

0.673
0.533
0.423

1.10
0.875
0.694

0.205
0.163
0.129

0.336
0.267
0.211

326
411
518
653

99.1
125
157
199

0.335
0.266
0.211
0.167

0.550
0.436
0.346
0.274

0.102
0.0811
0.0643
0.0510

0.168
0.133
0.105
0.0836

53.51
67.44
85.03
107.22

0.08291
0.1045
0.1318
0.1662

19(18)[18]
19(18)[18]
19(18)[18]
19(18)[18]

1.89
2.13
2.39
2.68

0.0745 9.19 0.362


0.0837 10.31 0.406
0.0940 11.58 0.456
0.1055 13.00 0.512

8.53 0.336
9.55 0.376
10.7 0.423
12.1 0.475

126.68
152.01
177.35
202.68

0.1963
0.2356
0.2749
0.3142

37(36)[35]
37(36)[35]
37(36)[35]
37(36)[35]

2.09
2.23
2.47
2.64

0.0822
0.0900
0.0973
0.1040

14.17
15.52
16.79
17.93

0.558
0.611
0.661
0.706

13.2
14.5
15.6
16.7

0.520
0.570
0.616
0.659

1149
1378
1609
1838

350
419
489
559

772
926
1081
1235

235
282
329
376

0.142
0.118
0.101
0.0885

0.232
0.194
0.166
0.145

0.0432
0.0360
0.0308
0.0270

0.0708
0.0590
0.0506
0.0442

500
600
750
1000

253.35
304.02
380.03
506.71

0.3927
0.4712
0.5890
0.7854

37(36)[35]
61(58)[58]
61(58)[58]
61(58)[58]

2.95
2.52
2.82
3.25

0.1162
0.0992
0.1109
0.1280

20.03
22.68
24.59
28.37

0.789
0.866
0.968
1.117

18.7
20.7
23.1
26.9

0.736
0.813
0.908
1.060

2298
2758
3447
4595

699
838
1048
1396

1544
1854
2316
3088

469
564
704
938

0.0708
0.0590
0.0472
0.0354

0.116
0.0967
0.0774
0.0580

0.0216
0.0180
0.0144
0.0108

0.0354
0.0295
0.0236
0.0177

1250
1500
1750
2000

633.38
760.06
886.74
1013.42

0.9817
1.178
1.374
1.571

91
91
127
127

2.98
3.26
2.98
3.19

0.1172
0.1284
0.1174
0.1255

31.75
34.80
37.59
40.21

1.250
1.370
1.480
1.583

5743
6892
8041
9190

1750
2100
2440
2790

3859
4631
5403
6175

1174
1410
1640
1880

0.0283
0.0236
0.0202
0.0177

0.0464
0.0387
0.0332
0.0290

0.00863
0.00719
0.00616
0.00539

0.0142
0.0118
0.0101
0.00885

250 kcmil
300
350
400

(a) Reduced number of wires for copper compact strandings shown in ( ) parentheses.
(b) Reduced number of wires for aluminum compact strandings shown in [ ] brackets.
(c) Approximate weights and average D.C. resistances are considered to apply to all types of strands.
Conductor data and metric equivalents in this table are based where possible on EEMAC recommendations current at time of
compilation, otherwise on published ICEA standards.

39

Wire and Cable Metric Calculations


Dimensions

Mass

Force or Tension

Length
mils x 0.0254 = mm (millimetres)
inches x 25.4 = mm
feet x 0.3048 = m (metres)
miles x 1.609344 = km (kilometres)

pounds x 0.45359 = kg (kilograms)


tons (2000 lb) x 0.907185 = t
(metric tonnes)

pounds (force) x 4.448 = N


(newtons)
mass (in kg) x 9.8066 = N
(weight at or near sea level)

Mass per unit length


lb/1000 ft. x 1.48816 = kg/km
(kilograms per kilometre)
lb/mi x 0.28185 = kg/km

Area
circular mils x 0.0005067 = mm2
(square millimetres)
sq. in x 645.16 = mm2
sq. ft. x 0.092903 = m2
(square metres)
sq. yd. x 0.836127 = m2
sq. mi. x 2.58999 = km2
(square kilometres)

Solid wire weight


mm2 x 8.89 = kg/km (for copper)
mm2 x 2.70 = kg/km (for aluminum)
mm2 x 7.83 = kg/km (for steel)

Temperature Conversion

Volume
cu. in. x 16.387 = cm3
(cubic centimetres)
cu. ft. x 0.028317 = m3
(cubic metres)
gallons x 4.54609 = L (litres)
U.S. gal. x 3.7854 = L (litres)

F to C: C = (F minus 32) x 5/9


C to F: F = (C x 9/5) plus 32

Force per unit area


(stress, pressure, tensile strength, etc.)
lbf/in2 = (psi) x 6.895 = kPa
(kilopascals)
lbf/in2 x 0.006895 = MPa
(megapascals)
N/mm2 = MPa
Note
Kilopascals are used generally for
fluid pressures. Megapascals are used
generally for stresses in materials, i.e.
for tensile stress, modulus of elasticity,
etc.

SI Prefixes
Multiplying factor
1 000 000 000 000
1 000 000 000
1 000 000
1 000
100
10
0.1
0.01
0.001
0.000 001
0.000 000 001
0.000 000 000 001
0.000 000 000 000 001
0.000 000 000 000 000 001

40

=
=
=
=
=
=
=
=
=
=
=
=
=
=

1012
109
106
103
102
101
10-1
10-2
10-3
10-6
10-9
10-12
10-15
10-18

Prefix

Symbol

NOTICE

tera
giga
mega
kilo
hecto
deca
deci
centi
milli
micro
nano
pico
femto
atto

T
G
M
k
h
da
d
c
m

n
p
f
a

Nexans has endeavored to ensure


the accuracy of the data in this
publication, however we cannot be
liable for the consequences of
errors or omissions. All data is
subject to change without notice.
The installer and/or user assumes
all liability for the consequences of
the installation and/or use of any
of our products in contravention of
any applicable law, regulation or
code.

Das könnte Ihnen auch gefallen