Sie sind auf Seite 1von 3

CODE:

FAILURE MODE EFFECTS ANALYSIS (FMEA)


DESIGN
Customer: Plant: Suppliers included:

Edition:

PROCESSS

RESOURCES
Prepared: Checked: Aproval: NPR=G x O x D

Date:

Product Denomination: Referencia/s: Customer modification Level:

Action/s Consecuences Ocurrence Gravity Recommended Action(s) Detection Area(s) / personal responsible(s) and realization Date

Ocurrence

Incorrect Terminal insertion Unriveted Terminal Terminals and Base plate Insertion Broken or damaged Base plate Non positioned Terminal Incorrect raw material Error Materiales PLACA BASE Wrong SMD Diode positionned Non positioned SMD Diode Tin scatterings Incorrect welding Incorrect Raw material

Relay Final conection dificulties Intermitent failure


Watertightness Failure

1 2 1

CI CS CI

Device or Operator failure Device failure Device failure Operator error Operator error Operator error Operator error Operator error Operator error Operador, Soldering Device or tin Operator error

1 1 1

* Visual check * 100% Final Control * Visual check * Visual check * Visual check * Aut. Final Control 100% * Visual check * Visual check * Manual Final Control 100% * Manual Final Control 100% * Visual check * Visual check

5 5 5

5 10 1

100% Function Failure Style failure Style failure Unprotected Relay Unprotected Relay Intermitent failure Unprotected Relay Unprotected Relay

3 1 1

CI CI

1 1 1

5 5 5

3 5 5

3 3 2 2


CS

1 1 1 1

5 5 10 5

10 15 20 10

Soldadura con base estao componente DIODO SMD a Gr. Placa Base entre Terminales T87 y T87A

CS CS

* Visual check

10

Tipo: : Crtica; CS: Significativa; CI: Importante

G: Leve(1)Grave(2)Muy Grave(3) O: Escasa(1)Moderada(2)Frecuente(3) D: Fcil (5)Normal(10)Difcil(15)


Pgina 1 de 3

NPR

Process description

Failure/s Potential/s Mode/s

Failure/s Potential/s Effect/s

Failure/s Potential/s Cause/s

Actual Verification(s) and/or Control(s)

Detection

Gravity

Type

Finished Action/s

100% Welded SMD Diode Presence and correct polarization Comprobation

Non positioned Diode SMD

Unprotected relay

Operator error

* 100% Manual Control

15

Incorrect SMD Diode colocation Broken Cu wire coil Riveted Magnet Core Remachado ncleo fuera especificacin Sin Ncleo Error Materiales BOBINAS Hilo bobina roto Terminales sin abrir ventanas Error Materiales BOBINAS Sin soldar

Unprotected relay

Operator error

* 100% Manual Control

15

Relay Doesn t work

Device failure

* 100% Manual Control * Medicin con comparador * Control Final Autom. 100% * Insp. Visual * Control Final Autom. 100% * Insp. Visual * Control Final Autom. 100% * Control Final Autom. 100%

30

Coil, Magnet core and yoke assembly and riveting

No cumple Pliego elctrico

CS

Fallo estacin Fallo ajuste

10

No funciona No cumple Pliego elctrico No funciona

Fallo operario

15

Fallo operario Fallo estacin Fallo ajuste Fallo estacin Fallo ajuste

10

30

10

30

Insercin Gr. Bobina en Gr. Placa Base y apertura ventanas terminales T85-86

Fallos intermitentes No cumple Pliego elctrico Fallos intermitentes No Funciona Fallos intermitentes Fallos intermitentes

CS

* Insp. Visual * Insp. Visual * Control Final Autom. 100% * Insp. Visual * Control Final Autom. 100% * Insp. Visual * ENS. DESTR. * Insp. Visual

10


CI

Fallo operario Fallo ajuste Fallo operario Fallo ajuste

15

15

Soldar Terminal T30 en culata

Soldadura defectuosa Proyecciones soldadura

20

Fallo ajuste

10

30

Tipo: : Crtica; CS: Significativa; CI: Importante

G: Leve(1)Grave(2)Muy Grave(3) O: Escasa(1)Moderada(2)Frecuente(3) D: Fcil (5)Normal(10)Difcil(15)


Pgina 2 de 3

Montaje ncora y muelle contacto, remachado y soldadura de trencilla Cu 0,75

Remachado defectuoso Defecto de soldadura de trencilla Error Materiales MUELLE CONT. Soldadura defectuosa

No cumple Pliego elctrico Fallo esttico

CS

Fallo estacin Fallo ajuste Fallo estacin Fallo ajuste Fallo operario

* Insp. Visual * Calibre P.Rey * Control Final Autom. 100% * Control Final Autom. 100% * Insp. Visual * Control Final Autom. 100% * Insp. Visual * ENS. DESTR. * Control Final Autom. 100% * Insp. Visual

10

40

CI

Fallo esttico

CI

Fallos intermitentes

CI

Fallo ajuste

Soldar Gr. Ancora en Gr. Rel y colocacin muelle de Traccin

Error Materiales GR. ANCORA Error Materiales MUELLE TRACCION Fallo de Tensiones nominales No cumple especificacin Fuerza entre contactos Error Materiales CARCASAS Presencia virutas o cuerpos extraos Sellado ilegible

Fallo esttico No cumple Pliego elctrico No cumple Pliego elctrico No cumple Pliego cond. Fuerza entre contactos Fallo esttico Fallos intermitentes No Funciona Fallo esttico Fallos tensiones de funcin Fallos cada de tensin Fallos prueba aislamiento 500 v.

CI CS

Fallo operario

10

Fallo operario

* Control Final Autom. 100% * Control Final Autom. 100% * Dinammetro * Galga 0,21 * Insp. Visual * Control Final Autom. 100% * Insp. Visual * Control Final Autom. 100% * Insp. Visual * Control Final Autom. 100% MA-1801 * Control Final Autom. 100% MA-1801 * Control Final Autom. 100% MA-1801

20

CI

Fallo ajuste

15

Ajuste elctrico de funciones, paso de galga 0,21mm. entre muelle contacto y Ncleo, soplado de carcasa y Gr. Rel y Colocacin de carcasa

Fallo ajuste

15

Fallo operario Fallo operario en soplado Fallo estacin

10

3 1

2 1

5 5

30 5

Comprobacin de 100% funciones elctricas, prueba aislamiento 500 v., prueba de cada de tensin y sellado de control 3 dgitos

Rels ajustables

Fallo ajuste Fallo montaje Falta limpieza Fallo montaje Fallo Bobina

30

15

Rels analizables

15

Tipo: : Crtica; CS: Significativa; CI: Importante