H.

264 Hybrid DVR Megapixel IP Camera Application System Diagram


2

H.264 Hybrid DVR

network DynaGuard 600 Series

Premium H.264 Hybrid DVR

Front Panel
5 3 1 2 4 6 8 7

Rear Panel
3 4
MAIN AUDIO OUT

8 9
LAN 10/100/1000M A U D IO IN

S -V ID E O

1 2

6
VGA

A L A R M I/O NAS

12

A U D IO O U T RS232

ON

10

11 13 14
PA L

15

16

17
OFF

18

NTSC

1 2 3 4

DVD/RW or Cartridge; optional USB 2.0 Ports Channel Keys Function Keys

5 6 7 8

LEDs Direction Keys IR Jog / Shuttle

1 2 3 4 5 6 7 8 9

Main Audio Output S-Video Output Call Monitor Output (BNC) Main Monitor Output (BNC) Audio Input VGA Output Digital Display Output Video Input Video Looping

10 11 12 13 14 15 16 17 18

Alarm I/O and RS-485 NAS Port (RJ45) LAN 10/100/1000M (RJ45) USB 2.0 Ports NTSC / PAL Switch RS-232 Audio Output; optional Power Switch Power Jack

Features
Advanced Functions H.264 / MPEG-4 / MJPEG compression Up to 8CH IP camera recording Megapixel recording Real-time recording Pentaplex operation User management Per channel configuration NTP for time synchronization WLAN, SMS Built-in Pelco Coaxitron protocol POS function: transaction monitoring Up to 4 internal SATA HDDs Supports internal DVD+RW Digital display output Dual-gigabit LAN ports 4/8/16CH audio recording Mobile View software DynaRemote for remote monitoring DynaGuard CMS for video management Humane Technology GUI USB mouse / USB keyboard; optional Control keyboard; optional IR remote control Jog / Shuttle UPnP Exports AVI file for Microsoft Media Player Modular Upgrade Kits T / V / U Module (DG600S only) for real-time recording DynaStorage 200 for extended recording storage Alarm Hub for 16CH alarm relay output Audio Module for 4/8/16CH audio output

H.264 Hybrid DVR

Specification
Item
Video Operation System Video Standard Input Input IP devices Outputs

DG604S / T

DG608S / V
Embedded (Linux) NTSC / PAL Switch Selectable BNC 8,1.0 Vp-p, 75 ohm Up to 8CH BNC 1, S-Video 1, 1.0 Vp-p, 75 ohm BNC 1, 1.0 Vp-p, 75 ohm BNC 8,1.0 Vp-p, 75 ohm 800 600, 1024 768, 1280 1024 pixels 800 600, 1024 768, 1280 1024 pixels NTSC: 30 pps/per CH, PAL: 25 pps/per CH Terminal Block 8, Line-In RCA 1, Line-Out ADPCM, G.726 8 KB/s, per CH

DG616S / T / U

BNC 4,1.0 Vp-p, 75 ohm Up to 4CH Main Monitor Call Monitor Loop

BNC 16,1.0 Vp-p, 75 ohm Up to 8CH

BNC 4,1.0 Vp-p, 75 ohm

BNC 16,1.0 Vp-p, 75 ohm

Digital Display Output VGA Output Picture Refresh Rate Audio Input Output Compression Method Data Rate Recording Compression Method Recording Mode Pre-alarm H.264 NTSC 720 480 PAL 720 576 MPEG-4 / MJPEG NTSC 720 480 PAL 720 576 Recording Quality Storage Mode Data Lifetime Storage Built-in Storage Interface Cartridge / DVD+RW External Storage Export Alarm Alarm Input Alarm Relay Output Alarm Detection Motion Detection Video Loss Detection Communication Network Connectivity Compatible IP Cameras Remote Control Software Remote Operation RS-232C RS-485 Dome Camera Control Protocol General Unit Dimension (W H D) Unit Weight Package Dimension (W H D) Package Weight Operation Temperature Relative Humidity Power Consumption & Input

Terminal Block 4, Line-In

Terminal Block 16, Line-In

4 SATA for HDD and DVD+RW Optional DynaStorage 200 (Gigabit LAN) 4 USB 2.0 Ports, Support ThumbDrive and DVD+RW 4, Terminal Block (TTL) 2, Terminal Block, 3.0A / 30 VDC or 3.0A / 125 VAC 16, Terminal Block (TTL) 8, Terminal Block (TTL) 2, Terminal Block, 3, Terminal Block, 3.0A / 30 VDC or 3.0A / 125 VAC 3.0A / 30 VDC or 3.0A / 125 VAC N.C. / N.O., programmable 15 11 Grid Array, Sensitivity, Trigger level adjustable Programmable

440 90 413 mm (17.3 3.54 16.3 inches) 7 Kg (15.42 lbs ) with DVD+RW 563 197 521 mm (22.17 7.76 20.51 inches) 10 Kg (22.03 lbs) 0 C ~ 40 C (32 F ~ 104 F) 10% ~ 90% Non-condensing AC 100 ~ 240V, 50-60 Hz, 200W (Manual select)

Product specification and availability subject to change without notice. Certain product names mentioned herein may be trade names and / or registered trademarks of their companies. Remark : DynaRemote Software Requirements: Windows 2000, XP or Vista, Intel Pentium M 1.40GHZ or faster, 512 MB RAM (1 GB RAM or above is recommended), Microsoft Internet Explorer 6.0 SP2, LAN or Internet connection.

System Diagram

Ethernet RJ45 connector, 10/100/1000 Mbps ACTi, AXIS, DynaColor, HUNT, SANYO, SONY, VIVOTEK DynaGuard CMS, DynaRemote Monitoring, Playback, Recording, System setup, Dome camera control, Archiving D-SUB 9 pin male Terminal Block DSCP, Pelco P, Pelco D, AD422, Fastrax 2, Panasonic, JVC

Application

H.264 (DG600S / T / V / U); MPEG-4 / MJPEG (DG600S / T) Schedule, Alarm, Motion Detection Yes S / V: Max 60 / 240 pps S / T: Max 60 / 120 pps S / T / U: Max 60 / 120 / 480 pps S / V: Max 50 / 200 pps S / T: Max 50 / 100 pps S / T / U: Max 50 / 100 / 400 pps S : Max 120 pps S / T: Max 120 / 120 pps S/T : Max 120 / 240 pps S : Max 100 pps S / T: Max 100 / 100 pps S/T : Max 100 / 200 pps 8 Levels Presets, Adjustable Linear / Circular Yes (Programmable)

Megapixel IP Camera

H.264 Hybrid DVR

H.264 Hybrid DVR Megapixel IP Camera Application System Diagram


4

H.264 Hybrid DVR

network DynaGuard 80 Series

Versatile H.264 Hybrid DVR

Front Panel
5
REC

Rear Panel
6
1 2 3 4 5 6 7 8

1 5 2

10

11

12

3 13 4

14

15

16

7
ESC
ENTER

1 2
1 2 3 4
COPY CALL DOME MODE PLAY

FREEZE

SEQ

SEARCH MENU

3 4
1 2 3 4 5 6

7 9 8 10
7 8 9 10 11 12

11

12

DVD/RW or Cartridge; optional USB 2.0 Port Channel Keys Function Keys

5 6 7

LEDs IR Direction Keys

UTP Ports; optional LAN 10/100M (RJ45) USB 2.0 Ports NTSC / PAL Switch VGA Port; optional Alarm I/O & Audio Input & RS-485 (Terminal Block)

Call Audio Output Main Audio Output Call Monitor Output (BNC) Main Monitor Output (BNC) Video Input Power Jack

Features
Advanced Functions H.264 / MJPEG compression Up to 2CH IP camera recording Quadplex operation User management Per channel configuration NTP for time synchronization Motion detection marker Up to 3 internal SATA HDDs Supports internal DVD+RW UTP connection; optional 4/8/16CH audio recording Mobile View software DynaRemote for remote monitoring DynaGuard CMS for video management Humane Technology GUI Touch panel USB mouse; optional Control keyboard; optional IR remote control

H.264 Hybrid DVR

Specification
Item
Video Operation System Input UTP; optional Input IP devices Outputs

DG84
BNC 4, 1.0 Vp-p, 75 ohm 4CH UTP Main Monitor Call Monitor

DG88
Embedded (Linux) BNC 8, 1.0 Vp-p, 75 ohm 8CH UTP Up to 2CH BNC 1, 1.0 Vp-p, 75 ohm BNC 1, 1.0 Vp-p, 75 ohm 800 600, 1024 768, 1280 1024 pixels NTSC: 30 pps/per CH, PAL: 25 pps/per CH Terminal Block 8, Line-In RCA 1, Line-Out RCA 1, Line-Out Proprietary 8 KB/s, per CH

DG86

362 90 350 mm (14.2 3.5 13.7 inches) 5.5 Kg (12.1 lbs) 410 210 500 mm (16.1 8.2 19.6 inches) 7 Kg (15.4 lbs) 0 C ~ 40 C (32 F ~ 104 F) 10% ~ 90% Non-condensing AC 100 ~ 240V, 50-60 Hz, 60W adaptor

Product specification and availability subject to change without notice. Certain product names mentioned herein may be trade names and / or registered trademarks of their companies. Remark : DynaRemote Software Requirements: Windows 2000, XP or Vista, Intel Pentium M 1.40GHZ or faster, 512 MB RAM (1 GB RAM or above is recommended), Microsoft Internet Explorer 6.0 SP2, LAN or Internet connection.

System Diagram

VGA Output; optional Picture Refresh Rate Audio Input Output Main Audio Call Audio Compression Method Data Rate Recording Compression Method Recording Mode Pre-alarm Recording NTSC 720 480 Resolution & Rate 720 240 360 240 PAL 720 576 720 288 360 288 Recording Quality Image Size Storage Mode Data Lifetime Storage Built-in Storage Interface Cartridge / DVD+RW Export Alarm Alarm Input Alarm Relay Output Alarm Detection Motion Detection Video Loss Detection Communication Network Connectivity Compatible IP Camera Remote Control Software Remote Operation RS-485 Dome Camera Control Protocol General Unit Dimension (W H D) Unit Weight Package Dimension (W H D) Package Weight Operation Temperature Relative Humidity Power Consumption & Input

Terminal Block 4, Line-In

Terminal Block 16, Line-In

Max 30 pps Max 60 pps Max 120 pps Max 25 pps Max 50 pps Max 100 pps

3 SATA for HDD and DVD+RW Optional 3 USB 2.0 Ports, Support ThumbDrive and DVD+RW 4, Terminal Block (TTL) 8, Terminal Block (TTL) 16, Terminal Block (TTL) 1, Terminal Block, 1.0A / 30 VDC or 1.0A / 120 VAC N.C. / N.O., programmable 16 12 Grid Array, Sensitivity, Trigger level adjustable Programmable

Ethernet RJ45 connector, 10/100 Mbps ACTi, AXIS, DynaColor, HUNT, SANYO, SONY, VIVOTEK DynaGuard CMS, DynaRemote Monitoring, Playback, Recording, System setup, Dome camera control, Archiving Terminal Block DSCP, Pelco P, Pelco D, AD422, Fastrax 2, Panasonic, JVC

Application

H.264 / MJPEG Schedule, Alarm, Motion Detection Yes Max 60 pps Max 120 pps Max 240 pps Max 50 pps Max 100 pps Max 200 pps 8 Levels Presets, Adjustable 1 KB to 22 KB/Picture Linear / Circular Yes (Programmable)

Megapixel IP Camera

BNC 16, 1.0 Vp-p, 75 ohm 16CH UTP

H.264 Hybrid DVR

H.264 Hybrid DVR Megapixel IP Camera Application System Diagram


6

H.264 Hybrid DVR

network DynaGuard L80 Series

Lite H.264 DVR

Front Panel
1 3 2 4 5 7 6

Rear Panel
1 3 2 4 5 6 7 8 9

1 2 3 4

IR LEDs Channel Keys Function Keys

Direction Keys

1 2 3 4 6 5 6

LAN 10/100M (RJ45) USB 2.0 Port VGA Port; optional Alarm I/O & Audio Input & RS-485 (D-SUB) Main Monitor Output (BNC) Main Audio Output

7 8 9

Video Input Audio Input Power Jack

Features
Advanced Functions H.264 compression Quadplex operation User management Per channel configuration NTP for time synchronization Motion detection marker Up to 2 internal SATA HDDs 4/8/16CH audio recording Mobile View software DynaRemote for remote monitoring DynaGuard CMS for video management Humane Technology GUI USB mouse (PS/2 protocol); optional Control keyboard; optional IR remote control; optional

H.264 Hybrid DVR

Specification
Item
Video Operation System Input Outputs

L84
BNC 4, 1.0 Vp-p, 75 ohm N/A

L88

L86

300 55 360 mm (11.8 2.2 14.2 inches) 2.3 Kg (5.1 lbs) 456 145 456 mm (18.0 5.7 18.0 inches) 3.8 Kg (8.4 lbs) 0 C ~ 40 C (32 F ~ 104 F) 10% ~ 90% Non-condensing AC 100 ~ 240V, 50-60Hz, 60W adaptor

Product specification and availability subject to change without notice. Certain product names mentioned herein may be trade names and / or registered trademarks of their companies. Remark : DynaRemote Software Requirements: Windows 2000, XP or Vista, Intel Pentium M 1.40GHZ or faster, 512 MB RAM (1 GB RAM or above is recommended), Microsoft Internet Explorer 6.0 SP2, LAN or Internet connection.

System Diagram

Main Monitor Call Monitor VGA Output; optional Picture Refresh Rate Audio Input Output Main Audio Call Audio Compression Method Data Rate Recording Compression Method Recording Mode Pre-alarm Recording NTSC 720 480 Resolution & Rate 720 240 360 240 PAL 720 576 720 288 360 288 Recording Quality Image Size Storage Mode Data Lifetime Storage Built-in Storage Interface Export Alarm Alarm Input Alarm Relay Output Alarm Detection Motion Detection Video Loss Detection Communication Network Connectivity Remote Control Software Remote Operation RS-485 IR Remote; optional Dome Camra Control Protocol General Unit Dimension (W H D) Unit Weight Package Dimension (W H D) Package Weight Operation Temperature Relative Humidity Power Consumption & Input

RCA 4, Line-In N/A

D-SUB 8, Line-In RCA 1, Line-Out RCA 1, Line-Out Proprietary 8 KB/s, per CH H.264 Schedule, Alarm, Motion Detection Yes Max 60 pps Max 120 pps Max 240 pps Max 50 pps Max 100 pps Max 200 pps 8 Levels Presets, Adjustable 1 K to 22 KB/Picture Linear / Circular Yes (Programmable) 2 SATA 1 USB 2.0 Port, Supports ThumbDrive, or DVD+RW

D-SUB 16, Line-In

Max 30 pps Max 60 pps Max 120 pps Max 25 pps Max 50 pps Max 100 pps

4, D-SUB (TTL)

8, D-SUB (TTL) 1, D-SUB, 1.0A / 30 VDC or 1.0A / 120 VAC N.C. / N.O., Programmable 16 12 Grid Array, Sensitivity, Trigger level adjustable Programmable

16, D-SUB (TTL)

Ethernet RJ45 connector, 10/100 Mbps DynaGuard CMS, DynaRemote Monitoring, Playback, Recording, System setup, Dome camera control, Archiving D-SUB Yes DSCP, Pelco P, Pelco D, AD422, Fastrax 2, Panasonic, JVC

Application

Megapixel IP Camera

Embedded (Linux) BNC 16, 1.0 Vp-p, 75 ohm BNC 8, 1.0 Vp-p, 75 ohm BNC 1, 1.0 Vp-p, 75 ohm BNC 1, 1.0 Vp-p, 75 ohm 800 600, 1024 768, 1280 1024 pixels NTSC: 30 pps/per CH, PAL: 25 pps/per CH

H.264 Hybrid DVR

H.264 Hybrid DVR Megapixel IP Camera Application System Diagram


8

H.264 Hybrid DVR

Value Chart
Performance
DG600V DG600T DG600S DG80 L80
COPY CALL DOME MODE PLAY FREEZE SEQ SEARCH MENU

DG600U

Price

Comparison Chart
Feature Recording Recording Rate (H.264 @ D1) Recording Rate (M / J @ D1) *Compression Method IP Camera Compatibility Per Channel Configuration Storage Max. HDDs Network Attached Storage Gigabit LAN Port USB Ports DVD Burner Remote Network DynaRemote S/W WLAN / SMS Upgrade Kits Audio Module T / V / U Module Alarm Hub UTP Module VGA Module Application DynaGuard CMS Mobile View S/W Time Synchronization UPnP Dual-Main Function Digital Display Output Operation Interface Jog / Shuttle USB Mouse USB Keyboard IR Remote Control Compact Control Keyboard GUI Touch Panel Premium H.264 DVR DG600 Series DG616S / T / U 60 / 120 / 480 120 / 240 / H/M/J 8 4 4 /-/ DG608S / V 60 / 240 120 / H/M/J 8 4 4 / DG604S / T 60 / 120 120 / 120 H/M/J 4 4 4 / DG86 60 60 (J) H/J 2 3 3 Versatile H.264 DVR DG80 Series DG88 60 60 (J) H/J 2 3 3 DG84 30 30 (J) H/J 2 3 3 L86 60 H 2 2 L88 60 H 2 2 L84 30 H 2 2 -

* : H stands for H.264 compression, M stands for MPEG-4 compression, J stands for MJPEG compression, V and U models dont support MPEG-4 and MJPEG compressions Supported Optional - Not supported The network DynaGuard series supports H.264 compression and Megapixel IP camera recording. It keeps all intelligent functions for managing and provides an integrated solution of recording videos from both existing analog cameras and oncoming IP cameras. With the hybrid video-in configurations, it saves the cost of replacement of camera devices in the period of IP transition. The Central Management System, DynaGuard CMS, is a free bundled video management software that allows the administrator to monitor up to 64 live video channels from cameras or DVRs, to record and playback on the PC using instant or schedule recording modes, and to archive the DVR recorded video remotely.

H.264 Hybrid DVR

Product Selection
DG6 Channels 04S: 4 CH S model 04T: 4 CH T model 08S: 8 CH S model 08V: 8 CH V model 16S: 16 CH S model 16T: 16 CH T model 16U: 16 CH U model HDD 000: None 016: 160 GB 032: 320 GB 050: 500 GB 064: 640 GB 075: 750 GB 100: 1000 GB Device Option 0: None M: Cartridge D: DVD+RW A: Audio Module Video System P: PAL N: NTSC

COPY

CALL

DOME

MODE

PLAY

FREEZE

SEQ

SEARCH MENU

D G0 8
Channels 4: 4 CH 8: 8 CH 6: 16 CH

HDD 000: None 016: 160 GB 032: 320 GB 050: 500 GB 064: 640 GB 075: 750 GB 100: 1000 GB Connection 0: BNC U: UTP Device Option 0: None M: Cartridge D: DVD+RW Video System P: PAL N: NTSC

Channels 4: 4 CH 8: 8 CH 6: 16 CH

HDD 000: None 016: 160 GB 032: 320 GB 050: 500 GB 064: 640 GB 075: 750 GB 100: 1000 GB

Device Option 0: None M: Cartridge D: DVD+RW

Video System P: PAL N: NTSC

Product specification and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of their companies.

System Diagram

Application

L08

Megapixel IP Camera

H.264 Hybrid DVR

H.264 Hybrid DVR Megapixel IP Camera Application System Diagram


14

Application

Central Management System

Features
Instant DVR and IP camera settings Up to 512 channels viewing eMap management Instant / scheduled recording Remote & local playback Image adjustment of recorded videos Event playback and alert notification Remote archiving / configuring Configuration exporting and importing Digital pan, tilt and zoom & 2-way audio Analog & IP speed dome control / IP joystick support User management / lock function HDD status report Multi-language support Smart motion playback

Specification
Item Input Devices Camera DVR Video Encoder / Dome Camera Video Format Video Channels Video Compression Resolution Recording Instant Recording Scheduled Recording Audio Recording w/ audio Live w/ audio Two-way audio Monitoring Live Monitoring Remote Playback Local Playback Snapshot Dome Camera Control Image Adjustment Event Playback Remote Archiving Search Notification System Requirement Operation System CPU Memory DynaGuard CMS NH Series / NW Series / AXIS 200 Series / Vivotek 7000 Series DG80 / DG200 / DG600 D7521 / DH500e / DH701e / DH801+e Up to 64CH H.264 / MJPEG / MPEG-4 Up to 2048 1536 Manually start / stop recording Scheduled time frame for recording Supports instant recording w/ audio Supports live display w/ audio Bidirectional audio transmission Different viewing modes / Full screen / Sequence Playback recorded videos remotely Playback recorded videos on PC Still image Multiple dome camera control protocols Brightness, Saturation, Hue, Contrast Select and playback events from the event list Select and archive events from the event list All events will be listed by time Event full screen / Alert notification Windows XP, Windows Vista Pentium 4, 2.0 GHz or above 1 GB or above