PowerLite EL-200 Series

Emergency Lighting Static Inverter System


Three Phase Input and Single Phase Output Static Inverters ranging from 10 20kVA BPC PowerLite EL-200 Series
High Performance Static Inverters, manufactured with the state of the art, PWM and IGBT technology, producing microprocessor controlled pure sinewave output to critical emergency lighting loads. EL - 200 Series are designed to the latest European EN 50171 specification for Emergency Lighting.

True double-conversion and PWM technology Inverter stage output Galvanic isolation transformer included Up to 91% efficiency Capable of 120% continuous overload to meet European Emergency Lighting regulations Parallel mode operation (optional) (hot standby, redundant, symmetric parallel) Pure sinewave output Larger 20Amp Charger for faster recharge of batteries Maintenance by-pass (for complete isolation of the inverter during maintenance) Unique Inverter design to suit high inrush lighting loads Bypass to load (changeover mode) user selection LCD panel providing accurate detailed information about the Load, Batteries and Inverter with advanced diagnostics. 3 Microprocessors ; - Main control board - Rectifier board - Optional parallel control board Real time clock and calendar indicator 64 Recorded real-time events history RS232 and dry contacts for communication and remote monitoring 1 year full warranty Experienced technical service and customer support Designed and manufactured under ISO9001 certification OPTIONALS :

Increased Power with parallel operation Increased reliability with 1+1 redundant operation Additional battery modules for extension of autonomy Wide Area Network management via SNMP. Remote monitoring panel RM -2000 Modbus connection for interface with BMS Systems Input / output customization
Unit may differ from picture

PowerLite EL-200 Series

Emergency Lighting Static Inverter Systems


Three Phase Input and Single Phase Output Static Inverters ranging from 10 20kVA
TECHNICAL SPECIFICATIONS :
MODEL
Output kVA Output kW Power factor EL210 10 8 EL215 15 12 0,8 230/400 VAC 3phase ,4Wires,+ ground +/ -15% 230 VAC Single Phase 50 Hz. +/- 5% 0,8 EN 50091-2 class A 230VAC Single Phase static (balanced load) +/- 1% static (unbalanced load) +/- 2% dynamic (step load 0-100%) +/- 5% after step load 0-100% max. 20ms. 50 Hz. Line sycnchronized +/- 1% free running +/- 0,2% >87-91% 3:1 Electronic short circuit protection 120% continuous, 150% load 10 min. 180% 1 min, 200% for 1 sec Linear Load < 3% Non linear load (75%NP and CF 3:1) <5% Maintenance free 30 405 300 VDC IU(DIN41773) 25C circuit breaker automatic battery test once a week dry contacts plus RS232 T-Mon standard / SNMP module optional IP41 0C to 40C Emergency Lighting EN 50171 Forced air cooling <1000 m. (above sea level) 90% max (non condensed) <56dbA 210 520 x 715 x 1170 EL220 20 16

INPUT
Voltage Tolerance By-pass Voltage Input frequency Power factor Max. RFI

OUTPUT
Voltage Voltage stability

Output Voltage recovery time Frequency Frequency tolerance Efficiency at 100% load Crest factor Short Circuit protection Over load capacity Total Harmonic distortion (THD)

BATTERIES
Type Number of 12V Blocks Float Charging Voltage End of discharge voltage Battery charging characteristics Battey Ambient TemperatureC Battery protection Battery Test

GENERAL
Serial communication Software Protection degree Ambient temp.(operating) Standard Ventilation Altitude Relative humidity Acoustic noise Weight Dimensiones (mm.) WxDxH

<56dbA 200

<56dbA 240

Issue 4