All the above consideration may not apply or less important for low volume production, high-priced products; such as pharmaceuticals.
Plants producing bulk chemicals are best located close to the source of the major raw material; where this is also close to the marketing area.
3. Transport Facilities
The transport of materials and products to and from the plant will be an overriding consideration in site selection. If practicable, a site should be selected that is close to at least two major forms of transport i.e., road, rail, waterway (canal or river), or a sea port. Land transport such as road transport is being increasingly used, and is suitable for local distribution from a central warehouse. Rail transport will be cheaper for the long-distance transport of bulk chemicals. Air transport is convenient and efficient for the movement of personnel and essential equipment and supplies, and the proximity of the site to a major airport should be considered.
4. Availability of labour.
Although the general trend is for increased automation, many processes would still require a reasonably large labour force. Labour will be needed for construction of the plant and its operation. Skilled construction workers will usually be brought in from outside the site area, but there should be an adequate pool of unskilled labour available locally; and labour suitable for training to operate the plant. Skilled tradesmen will be needed for plant maintenance.
Local trade union customs and restrictive practices will have to be considered when assessing the availability and suitability of the local labour for recruitment and training.
In addition, the local pay rates, competing industries and turnover rates need to be also considered.
9. Climate.
Climate can have an important bearing on the economic operation of the process. Either a hot or cold severe climate, the cost of protective buildings, facilities for personnel and utilities must be considered especially when performing the economics.
Site/Plant Layout
As with so many aspects of design, the layout of a process plant is not an exact science but rather an art, as it embraces a high degree of experience coupled with the need to anticipate the human elements in both operation and maintenance. It is an important factor in that a carefully planned, functional arrangement of equipment, buildings and pipeworks is the key to economical construction and efficient operation.
The ancillary buildings and services required on a site, in addition to the main processing units (buildings), will include (cont); Fire stations and other emergency services. Utilities: steam boilers,compressed air, power generation, refrigeration, transformer stations. Effluent disposal plant. Offices for general administration. Canteens and other amenity buildings, such as medical centres. Car parks.
There are two general methods which plant equipment could be positioned ; i. Group Pattern vessels, exchangers, columns, pumps etc., are grouped together in separate areas for ease of operation and maintenance ii. Flowline Pattern - equipment is laid out as arranged on the process flowsheet. In larger plants, the first method is always used due to large numbers of similar units being employed. However, in practise a compromise between the two methods is normally used.
The following guidelines may be employed in designing the site/plant layout ; i. Minimum Labour Demands When labour cost is high, automation could result in significant reduction in labour demands. Therefore, a central control room is required. Nevertheless, some labour outside the control room is still required to perform certain manual operation but is kept to a low number. For batch operation and start up/shut down operation of continuous plants where labour demands are high, considerable savings could be made by arranging the units in an integrated manner as much as possible. This will minimise movements required over all the unit and thus could reduce the labour required. This will also help in the case of maintenance provided proper spacing is allocated for the all the units. ii. Elevation of Equipment Elevation of equipments is expensive and should only be kept to the absolutely necessary ones to ensure efficient operation eg. units employing gravity flow. There are cases where heavy and bulky items are elevated such as reactor but to arrange its elevation with the rest of the process according to the process flow will enable advantage to be taken on using the gravity as the flow force this eliminating pumps/compressors/conveyor belt thus cheaper on maintenance. In general, heavy and bulky unit should be placed on the ground with proper support even at the expense of using pressure to force the flow unnaturally eg. pressure in distillation unit pushes the vapour flow down to almost ground level where condenser is located.
iii. Operating Convenience Equipments requiring frequent attention should be grouped together to facilitate operation and maintenance. However, the safety clearance between the units have to be observed to ensure safest possible arrangement and the most hazard prone equipment is placed at the location most convenient for it to be removed. A rectangular setup with a central over head pipe rack permits equipments to be installed along both sides of the pipe way with ease of access. iv. Lay out of Specific Plant Equipments It is convenient to locate pumps in line along each side of an access way with the motors aligned outwards for easy access maintenance. Equipments requiring large cranes for services should be located at the perimeter of the rectangular set up, adjacent to a main roadway. Compressors (expensive items) should be installed to allow for rapid dismantling and reassembly thus avoiding from the needs to have a stand by unit. Use compressors with bottom suction and discharge connections and supporting it on a platform above ground level (approx 2.5 m or so) v. Layout of Process Units Large individual process units should be separated for efficient operation and maintenance and to avoid possible spread of fire and explosion. A master plan should be made for grouping these equipments together and for future expansion.
Other useful factors to consider; The cost of construction can be minimised by adopting a layout that gives the shortest run of connecting pipe between equipment, and the least amount of structural steel work. However, this will not necessarily be the best arrangement for operation and maintenance. Valves, sample points, and instruments should be located at convenient positions and heights. Heat exchangers need to be sited so that the tube bundles can be easily withdrawn for cleaning and tube replacement. Vessels that require frequent replacement of catalyst or packing should be located on the outside of buildings. Equipment that requires dismantling for maintenance, such as compressors and large pumps, should be placed under cover. Blast walls may be needed to isolate potentially hazardous equipment, and confine the effects of an explosion. Equipment should be located so that it can be conveniently tied in with any future expansion of the process. Space should be left on pipe alleys for future needs, and service pipes over-sized to allow for future requirements.
Other useful factors to consider (cont.) Services.; Buildings of an ancilliary nature such as offices, workshops, canteen and power supply should be located so as to afford maximum convenience with minimum interference with operation of the plant. Relief devices that can vent inflammable and noxious fumes in an emergency should be located down wind of the administrative facility. Storage areas should be positioned for ease of access from public roads and railways and remote from hazardous areas. Facilities for generation and distribution of services (power supply, steam & water supply) should be located in a completely safe area. For road used by all types of vehicles at all times, they should be surfaced and main twoway road should be at least 20ft (6.1 m) width with 30 ft (9.3 m) minimum centre line radius to permit the turning of 3-4 axle vehicles.
Other useful factors to consider (cont.) Piping; Overhead pipe network / yard piping which carries process materials and main utilities are normally long and should be sited at or below ground level using racks. In most cases, the power supply and instruments line are carried on the same structure. Large pipes carrying process materials through the main process equipments should be made as shortest possible but meeting all the clearance required. This could be achieved by grouping the common equipments together.
Conclusions
We have gone through a number of main factors governing ; the selection of site location which could have significant impact on the construction and operation of the process plant. the design of site layout which takes into account of operation and maintenance requirement
Above all, there is no clear / systematic guidelines or procedures for designing site layout other than leveraging on some common sense rules thus making it more of an art rather than scientific approach.
VHP
Fuel BOILER /USING FUEL OR GAS TURBINE EXHAUST POWER BACK PRESSURE TURBINE
Condensate Return
Boiler Blowdown
HP
POWER
MP
POWER LET DOWN VALVE CONDENSING TURBINE
LP
CW
The centralised utility system supplies steam, power and cooling water to the processes. It can also supply compressed air and refrigeration.
Steam Supply
PROCESS 1
Condensate Return Steam Supply CENTRALISED UTILITY SYSTEM
PROCESS 2
Condensate Return Steam Supply
PROCESS 3
Condensate Return
POWER
The main components or equipments in the central utility system normally comprise of; 1. Boiler feedwater treatment
To treat water for removing suspended solids, dissolved solids, dissolved salts and dissolved gases.
Filter
To remove particularly calcium and magnesium which could cause fouling in heat exchanger To remove all inorganic salts by using strong acid cation and base anion resin.
Ion Exchange
Vent To remove dissolved gases principally O2 and CO2 which could cause corrosion. LP steam
Chemical Treatment
To further remove the remaining metal ions and dissolved gases left
Deaerator To boiler
2. Steam Boilers
Fire tube boiler.
A fire-tube boiler is a type of boiler in which hot gases from a fire pass through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the water and ultimately creating steam.
3. Steam Turbines
A steam turbine is a mechanical device that extracts thermal energy from pressurized steam, and converts it into rotary motion. It has almost completely replaced the reciprocating piston steam engine primarily because of its greater thermal efficiency and higher power-to-weight ratio. Because the turbine generates rotary motion, it is particularly suited to be used to drive an electrical generator about 80% of all electricity generation in the world is by use of steam turbines. The steam turbine is a form of heat engine that derives much of its improvement in thermodynamic efficiency through the use of multiple stages in the expansion of the steam, which results in a closer approach to the ideal reversible process.
HP
LP
4. Gas Turbines
A gas turbine, also called a combustion turbine, is a rotary engine that extracts energy from a flow of combustion gas. It has an upstream compressor coupled to a downstream turbine, and a combustion chamber in-between. Energy is added to the gas stream in the combustor, where fuel is mixed with air and ignited. In the high pressure environment of the combustor, combustion of the fuel increases the temperature. The products of the combustion are forced into the turbine section. There, the high velocity and volume of the gas flow is directed through a nozzle over the turbine's blades, spinning the turbine which powers the compressor and, for some turbines, drives their mechanical output. The energy given up to the turbine comes from the reduction in the temperature and pressure of the exhaust gas.
GE H series power generation gas turbine: in combined cycle configuration, this 480-megawatt unit has a rated thermal efficiency of 60%.
Steam system typically has 3 levels of steam pressure namely HP, MP and LP. For larger sites, a higher level namely very high pressure (VHP) steam is generated for power production. The let down steam from the turbine is then channeled into the steam system.
At times, the steam is expanded to lower pressure using expansion valve.
Flow control, or metering, of the expanded fluid is accomplished by use of a temperature sensing bulb filled with a similar gas as in the system that causes the valve to open against the spring pressure in the valve body as the temperature on the bulb increases.
Also, every steam heaters used for heating process stream will be equipped with steam traps.
A steam trap is a device used to discharge condensate and non condensable gases with a negligible consumption or loss of live steam. Most steam traps are nothing more than automatic valves. They open, close or modulate automatically. Others, like venturi traps, are based on turbulent 2-phase flows to obstruct the steam flow. The three important functions of steam traps are: Discharge condensate as soon as it is formed. Have a negligible steam consumption. Have the capability of discharging air and other non-condensable gases.
5. Cooling Water
Cooling water circulation is used for process cooling such as in condenser or cooler. The cooling water used has to be treated where possible to minimise fouling and corrosion thus extending equipment life and maintaining efficient heat transfer. Natural and forced-draft cooling towers are generally used to provide the cooling water required on a site; unless water can be drawn from a convenient river or lake in sufficient quantity. Sea water, or brackish water, can be used at coastal sites, but if used directly will necessitate the use of more expensive materials of construction for heat exchangers.
Cooling tower constitutes the main component of the cooling water circulation system besides the pumps needed for the water circulation and the chemical treatment required.
Cooling Tower
Industrial cooling towers can be used to remove heat from various sources such as machinery or heated process material. The primary use of large, industrial cooling towers is to remove the heat absorbed in the circulating cooling water systems used in power plants, petroleum refineries, petrochemical plants, natural gas processing plants, food processing plants, semi-conductor plants, and for other industrial facilities such as in condensers of distillation columns, for cooling liquid in crystallization, etc. A typical large refinery processing 40,000 metric tonnes of crude oil per day (300,000 barrels (48,000 m3) per day) circulates about 80,000 cubic metres of water per hour through its cooling tower system. There are 3 main types of heat transfer mechanism employed: Wet cooling towers or simply open circuit cooling towers operate on the principle of evaporation. The working fluid and the evaporated fluid (usually H2O) are one and the same. Dry Cooling Towers operate by heat transfer through a surface that separates the working fluid from ambient air, such as in a tube to air heat exchanger, utilizing convective heat transfer. Fluid coolers or Closed Circuit Cooling Towers are hybrids that pass the working fluid through a tube bundle, upon which clean water is sprayed and a fan-induced draft applied.
There are three types of cooling towers: Natural draft, which utilizes buoyancy via a tall chimney. Warm, moist air naturally rises due to the density differential to the dry, cooler outside air. Mechanical draft, which uses power driven fan motors to force or draw air through the tower. Induced draft: A mechanical draft tower with a fan at the discharge which pulls air through tower. Forced draft: A mechanical draft tower with a blower type fan at the intake. The fan forces air into the tower, creating high entering and low exiting air velocities.
Conclusions
We have gone through the main components and arrangement of a typical plant centralised utility system which consists of ; Boiler feed water treatment Steam boiler Steam Turbine Gas Turbine Steam System Configuration Cooling water Refrigeration (only for plant with sub ambient temperature operation)
Together, they form the main and important support for ensuring successful plant operation.