Oiltech LOC with integrated circulation pump for industrial hydraulic systems

OILTECH LOC

FOR OPTIMUM EFFICIENCY

Oiltech LOC is one of the most reliable and efficient cooling system for oil cooling on the market. The oil in your hydraulic system will operate with the ideal oil viscosity, providing extended service life and dependability for your entire hydraulic system.

Cooler matrix with low pressure drop and high cooling capacity Three-phase AC-motor. Cooling capacity up to 45 kW at ETD 40C (40C difference in inlet temperature oil/air). The pump can be installed turned in steps of 90 on the electromotor.

Oiltech LOC cooling system consists of a cooler matrix, a fan and a pump, The cooling system is fitted with one electromotor only minimising the electric installation, providing ease of assembly at a low cost of installation.

Ease of installation
During the development of Oiltech LOC, cooling capacity tests, analyses of life cycle and structural strength have been made in our laboratory.All components have been thoroughly selected for optimum performance. Compact design and ease of mounting facilitates installation in small locations. The cooling system is supplied fit for installation in your system. The Oiltech LOC can be fitted with a filter unit for oil cleaning, providing extended oil durability, hence extended hydraulic system life. Functions such as pumping, cooling and filtering in one compact package assures optimal performance at low cost.

efficiency and expanded productivity. A controlled oil temperature will result in extended component life. For flexibility of selection and application, Oiltech LOC standard range is available in capacities from 2.8 kW to 45 kW at ETD 40C and oil flows from 20 l/min to 80 l/min. Fitted with Oiltech QPM quiet low-pressure pump, the system will operate with a uniform oil flow pattern. Pulsations and pressure spike problems from the hydraulic system are eliminated, providing extended system service life. The extremely high heat transfer capacity, the dependability in operation and the fact that Oiltech LOC provides longlasting oil durability is significant for this cooling system.

Calculate your cooling requirement


Oiltech has developed a calculation program where, by entering your basic data, you can calculate your cooling requirement and select the correct cooling system. The program is available from you local Olaer company. The Olaer Group is represented worldwide providing you with support wherever you are located.

Reliability in operation and extended life


Oiltech LOC cooling system provides proven reliability, measured in lower maintenance costs, increased system

General drawing

* Oil
Dust and stone guard

Air

Dimensions Type
Oiltech LOC 004-4-D-A Oiltech LOC 007-4-D-A Oiltech LOC 007-4-D-B Oiltech LOC 007-4-D-C Oiltech LOC 007-4-D-D Oiltech LOC 011-4-D-A Oiltech LOC 011-4-D-B Oiltech LOC 011-6-D-C Oiltech LOC 011-6-D-D Oiltech LOC 011-4-D-C Oiltech LOC 011-4-D-D Oiltech LOC 016-4-D-A Oiltech LOC 016-4-D-B Oiltech LOC 016-6-D-C Oiltech LOC 016-6-D-D Oiltech LOC 016-4-D-C Oiltech LOC 016-4-D-D Oiltech LOC 023-4-D-B Oiltech LOC 023-6-D-C Oiltech LOC 023-6-D-D Oiltech LOC 023-4-D-C Oiltech LOC 023-4-D-D Oiltech LOC 033-6-A-D Oiltech LOC 033-4-A-C Oiltech LOC 033-4-A-D Oiltech LOC 044-6-A-D Oiltech LOC 044-4-A-C Oiltech LOC 044-4-A-D

A 267 365 365 365 365 440 440 440 440 440 440 496 496 496 496 496 496 580 580 580 580 580 692 692 692 692 692 692

B 287 395 395 395 395 470 470 470 470 470 470 526 526 526 526 526 526 610 610 610 610 610 722 722 722 866 866 866

C 134 203 203 203 203 203 203 203 203 203 203 203 203 203 203 203 203 356 356 356 356 356 356 356 356 356 356 356

D 66 81 81 81 81 119 119 119 119 119 119 147 147 147 147 147 147 112 112 112 112 112 168 168 168 168 168 168

E 500 526 539 586 599 551 564 611 624 611 624 610 623 636 649 636 649 648 661 717 704 717 754 722 735 779 746 759

F 420 510 510 510 510 510 510 510 510 510 510 510 510 510 510 510 510 610 610 610 610 610 610 610 610 610 610 610

G 80 160 160 160 160 230 230 230 230 230 230 230 230 230 230 230 230 305 305 305 305 305 406 406 406 584 584 584

H 77 103 103 103 103 106 106 106 106 106 106 100 100 100 100 100 100 101 101 101 101 101 103 103 103 87 87 87

I 130 112 112 112 112 110 110 110 110 110 110 114 114 114 114 114 114 112 112 112 112 112 101 101 101 101 101 101

J 169 212 212 212 212 250 250 250 250 250 250 278 278 278 278 278 278 320 320 320 320 320 376 376 376 448 448 448

K 163 190 190 190 190 215 215 215 215 215 215 240 240 240 240 240 240 265 265 265 265 265 240 240 240 265 265 265

L* 63 42 42 42 42 39 39 39 39 39 39 45 45 45 45 45 45 44 44 44 44 44 43 43 43 59 59 59

M G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G11/4 G11/4 G11/4 G11/4 G11/4 G11/4

N 62 62 75 87 100 62 75 87 100 87 100 62 75 87 100 87 100 75 87 100 87 100 100 87 100 100 87 100

* "L" when a by-pass valve type S is used

Oiltech LOC, designed for use with synthetic oils, vegetable oils and mineral oil type HL/HLP according to DIN 51524. Maximum oil temperature 100C. Maximum negative pressure in suction line 0,4 bar with oil-filled pump. Technical specification, cooler matrix Maximum static working pressure Dynamic working pressure Heat transfer tolerance 6 % 21 bar 14 bar. Tested acc. to ISO/DIS 10771-1

Material Pump housing/Matrix Aluminium Fan blades/hub Fan housing Fan guard Other parts Surface treatment Glass fibre reinforced polypropylene/aluminium Steel Steel Steel Electrostatic powder coating

Technical specification, three phase-motor Three-phase asynchronous motor acc. to IEC 34-1, IEC 72 to DIN 57530/VDE 0530 Rated voltage: 50 Hz 220-240V/380-420V or 60 Hz 255-290V/440-480V Insulation class Rise in temperature Protection standard F B IP 55

Consult your local Olaer company for use with oil temperatures >100C with oil viscosity > 100 cSt/other fluids in aggressive environments ambients, rich in particles at high altitudes
ca pa cit y* Nu m be ro fp ol es Fa n

Data at 50 Hz
(l/ m in ) (k W /C )

Ac kW ou at st ET ic D pr 40 es su C re L pA Ac (d ou B( A) st ic )1 po m ** we rL Ai rf WA lo w (d B( (m 3 A) /s ) ec )

No m .o il flo w

Co ol in g

Type
Oiltech LOC 004-4-D-A Oiltech LOC 007-4-D-A Oiltech LOC 007-4-D-B Oiltech LOC 007-4-D-C Oiltech LOC 007-4-D-D Oiltech LOC 011-4-D-A Oiltech LOC 011-4-D-B Oiltech LOC 011-6-D-C Oiltech LOC 011-6-D-D Oiltech LOC 011-4-D-C Oiltech LOC 011-4-D-D Oiltech LOC 016-4-D-A Oiltech LOC 016-4-D-B Oiltech LOC 016-6-D-C Oiltech LOC 016-6-D-D Oiltech LOC 016-4-D-C Oiltech LOC 016-4-D-D Oiltech LOC 023-4-D-B Oiltech LOC 023-6-D-C Oiltech LOC 023-6-D-D Oiltech LOC 023-4-D-C Oiltech LOC 023-4-D-D Oiltech LOC 033-6-A-D Oiltech LOC 033-4-A-C Oiltech LOC 033-4-A-D Oiltech LOC 044-6-A-D Oiltech LOC 044-4-A-C Oiltech LOC 044-4-A-D

Co ol ing

20 20 40 60 80 20 40 40 55 60 80 20 40 40 55 60 80 40 40 55 60 80 55 60 80 55 60 80

0,07 0,13 0,17 0,18 0,18 0,19 0,26 0,19 0,22 0,29 0,30 0,26 0,38 0,31 0,35 0,45 0,49 0,52 0,42 0,46 0,60 0,66 0,65 0,80 0,87 0,85 1,00 1,12

2,7 5,2 6,8 7,2 7,2 7,6 10,4 7,6 8,8 11,6 12,0 10,4 15,2 12,4 14,0 18,0 19,6 20,8 16,8 18,4 24,0 26,4 26,0 32,0 34,8 34,0 40,0 44,8

57 64 64 65 65 70 70 61 61 70 70 74 74 64 64 74 74 77 67 67 77 77 74 85 85 77 86 86

67 73 73 74 74 79 79 70 70 79 79 83 83 73 73 83 83 87 77 77 87 87 84 95 95 87 96 96

0,058 0,29 0,29 0,29 0,29 0,61 0,61 0,37 0,37 0,61 0,61 0,96 0,96 0,58 0,58 0,96 0,96 1,50 0,92 0,92 1,50 1,50 1,52 2,41 2,41 1,89 2,99 2,99

4-0,75 4-0,75 4-0,75 4-1,50 4-1,50 4-0,75 4-0,75 6-1,10 6-1,10 4-1,50 4-1,50 4-1,50 4-1,50 6-1,10 6-1,10 4-1,50 4-1,50 4-1,50 6-1,10 6-1,50 4-2,20 4-2,20 6-2,20 4-3,00 4-3,00 6-2,20 4-3,00 4-3,00

200 325 325 325 325 400 400 400 400 400 400 456 456 456 456 456 456 538 538 538 538 538 650 650 650 650 650 650

* Specified electromotors are calculated for max. working pressure 6 bar at 125 cSt and 50 Hz; 4 bar at 125 cSt and 60 Hz. For working pressures above this, consult your local Olaer company for higher rated electromotors. ** Noise level tolerance 3 dB(A).

di am et er (m m W ) ei gh ta pp ro x. kg

ca pa cit yi n

ca pa cit y

-C oo lin g

23 30 30 36 36 34 34 40 40 40 40 45 45 45 45 45 45 53 53 53 62 62 92 76 76 98 85 85

Ordering key for Oiltech LOC cooling system. When ordering every item should be specified.

LOC- X X X - X - X - X - X - X X - X X X - X - X - X 1 2 3 4 5 6 7 8 9 10 11

1. Cooling system with AC-motor and circulation pump = LOC 2. Cooler size 004 007 011 3. Number of poles, motor 4-pole =4 6-pole =6

016 023 033

044

4. Voltage and frequency Three-phase, 230/400V, 50 Hz Three-phase, 275/480V, 60 Hz Three-phase, 230/400V 50 Hz, 275/480V 60 Hz Three-phase, 500V, 50 Hz Three-phase, 400/690V, 50 Hz Motor for special voltage (in text en clair) 6. By-pass valve, pump Without by-pass valve Built-in by-pass valve, 5 bar Built-in by-pass valve, 10 bar 8. Cooler matrix Standard Two pass
Built-in, pressure controlled by-pass valve, single-pass

= = = = = =

A B D E F X

5. Pump size Displacement Displacement Displacement Displacement Special

15 30 45 60

cm3/r cm3/r cm3/r cm3/r

= = = = =

A B C D X

7. Thermo contact =0 =L =H

(For temperature warning. Not for electromotor control)

= 000 = T00 = S20 = S50 = S80 = T20 = T50 = T80

Without thermo contact 40C 50C 60C 70C 80C 90C 9. Matrix guard Without guard Stone guard Dust guard Dust and stone guard

= = = = = = =

00 40 50 60 70 80 90

2 bar 5 bar 8 bar


Built-in, pressure controlled by-pass valve, two-pass*

2 bar 5 bar 8 bar 50C, 60C, 70C, 90C, 50C, 60C, 70C, 90C, 2,2 2,2 2,2 2,2 2,2 2,2 2,2 2,2 bar bar bar bar bar bar bar bar

= = = =

0 S D P

Built-in, temperature and pressure controlled by-pass, single-pass

= = = = = = = =

S25 S26 S27 S29 T25 T26 T27 T29

Built-in, temperature and pressure controlled by-pass, two-pass*

* Not available for Oiltech LOC 004

10. Filter and filter housing Without filter housing =0 Filter housing, without filter cartridge =H Filter housing, filter cartridge 10 m/visual indicator = V Filter housing, filter cartridge 10 m/electrical indicator = E
(filter housing adapted to DIN cartridges)

11. Standard/special Standard Special

=0 =Z

Example: LOC-011-6-A-C-L-50-S20-D-E-0
For further information and latest modifications, please enter our homesite www.oiltech.se. To facilitate selection of air oil cooler, order Oiltech's calculation programme. When a special cooler is required, please specify product, components, performance, dimensions etc, in text en clair. Price and time of delivery available on request.

Das könnte Ihnen auch gefallen