Overflow from Biosolids storage

246 MIN 97 MIN

1618 SaniTEE Screens Influent See note 4

Decant pump

29.7 11.7 PVC Length based on MIN Outlet height Lateral Brace by others Biosolids Collection 6" PVC Outlet

Settling Zone 91.44 36

Treatment Zone

NOTES: 1. The air supply line into the FAST unit must be secured so as to prevent damage from pipe vibration. 2. The units are supplied with 3" semi-flexible airline connections with stainless steel MPT fittings. Each blower will require 4" 3. steel pipe to connect to the distributed airlift system. 4. Influent pipe shall be positioned to maximize settling. A prescreening device may be utilized based on the individual site conditions and characteristics of the influent. MyFAST 4.0 (4) 1618 SaniTEE Screens Blowers and Blower Housings Central Control Panel Biosolids collection piping (4) MyFAST Segments

Biosolids Pump Pit

OPTIONAL MyFAST 4.0 BMS (Biosolids Management System) Sludge Pump 6" PVC Decant Pump Outlet LIXOR 2.0 Effluent Jib Crane Collection Pipe
Biosolids Storage Zone
DO NOT SCALE

FAST Blower

Airlines

LIXOR 2.0

Biosolids release to Dewatering Station provided by others BIO-MICROBICS 2010

UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS] TOLERANCES 0.02 IN/IN [ 0.05 CM/CM]
WEIGHT lb
SIZE DRAWING NUMBER NAME DATE DRAWN CTC 3/27/2009

MyFAST 4.0
A

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

Layout
REVISED 5/25/2010 REV.

SHEET 1 OF 6
INI-02-M

CHECKED PF 5/25/2010

Influent Emergency overflow from Biosolids Storage Zone

Settling Zone 20,000 Gallon MIN [76 m3 MIN] 472.44 MIN 186.0 MIN

Treatment Zone 40,000 Gallon MIN [151 m3 MIN]


115225 453.6010.00

16" SaniTEE Screen placement

78.74 MIN 31 MIN 76 MIN 30 MIN 122 MIN 48 MIN 101525 40010

59413 2345

Biosolids release to Dewatering Station

Biosolids Pump Pit


Biosolids Storage Zone 8400 Gallon MIN [32 m3 MIN] 91 MIN 36 MIN 20 8 58 MIN 23 MIN Freeboard 91 MIN 36 MIN

79 31

188 74

297 117

406 160

30 12

20.3 8 76.75

264 104

246 MIN 97.0 MIN

8
246 MIN 97 MIN 264 MIN 104 MIN 229 MAX 90 MAX BioSolids Water Level 6

PVC Pipe
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS] TOLERANCES 0.02 IN/IN [ 0.05 CM/CM]
WEIGHT lb
SIZE DRAWING NUMBER NAME DATE DRAWN CTC 3/27/2009

PVC Pipe opening

MyFAST 4.0
A

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

BIO-MICROBICS 2010

Tank Details
REVISED 5/25/2010 REV.

SHEET 2 OF 6

CHECKED PF 5/25/2010

INI-01-Q

8" PVC piping by others connects sludge pump pit to collection piping 8 PVC TEE

1601 63.5

1551 61.5

PVC Pipe

6 6 PVC TEE 6 PVC Elbow

PVC Pipe

1601 63.5

959 378

Notes: 1. Biosolids Collection Supplied by Bio-Microbics 2. Secure Biosolids Collection grid every 36" [90cm]

DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS] TOLERANCES 0.02 IN/IN [ 0.05 CM/CM]
WEIGHT lb
SIZE DRAWING NUMBER NAME DATE DRAWN CTC 3/27/2009

MyFAST 4.0
A

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

BIO-MICROBICS 2010

Biosolid Collection
REVISED 5/25/2010 REV.

SHEET 3 OF 6

CHECKED PF 5/25/2010

INI-01-I

OPTIONAL DIGEST ZONE Jib crane Biosolids Pump Outlet

36
Electrical conduit to Bio-Microbics control panel provided by others

2 screws per side included See Note 1

57
3" MIN air supply line utilizing galvanized or stainless steel piping from the blower housing to the treatment tank provided by others.

35

29.72 MIN 12 MIN

Decanting Pump See note 7

Concrete base provided by others

Minimum leg extension assembly See Note 2 & 3

Return to Treatment Zone

Biosolids Pump See note 6 LIXOR 2.0 See Note 5

Notes: 1. Secure leg extension to the FAST unit by placing two screws on each side of the leg extension (4 screws per foot are included). 2. To obtain the desired height of leg cut 4" [10] schd. 40 PVC pipe (not included). Minimum pipe length of 11 1/8" [28.26]; For heights greater then 18" [45.7] use schd. 80 PVC pipe (not included). Consult factory for extending leg beyond 36"[91]. 3. Anchor the leg extensions to the tank with non-corrosive hardware (not included) at the provided mounting points. 4. Tank, anchors, piping conduit, blower, housing pad and vents are provided by others. 5. LIXORs must be spaced in Biosolids Storage Zone for maximum mixing and aeration. Consult Bio-Microbics. 6. Sludge pump discharge piping must create at least 22' [6.7m] of TDH at 60 Hz and 8' [2.4m] of TDH at 50 Hz. 7. Decant pump discharge piping must create at least 22' [6.7m] of TDH at 60 Hz and 8' [2.4m] of TDH at 50 Hz.
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS] TOLERANCES 0.02 IN/IN [ 0.05 CM/CM]
WEIGHT lb
SIZE DRAWING NUMBER

MyFAST 4.0
A

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

BIO-MICROBICS 2010

NAME DATE DRAWN CTC 3/27/2009

Details
REVISED 5/25/2010 REV.

SHEET 4 OF 6
INI-05-K

CHECKED PF 5/25/2010

Specifications for MyFAST 4.0 Wastewater Treatment System 1. GENERAL The contractor shall furnish and install (1) MyFAST 4.0 treatment system as manufactured by Bio-Microbics, Inc. The treatment system shall be complete with all equipment as shown on the drawings and specified herein. The principal items of equipment shall include four (4) FAST interconnecting inserts with leg attachments, biosolids collection manifold, four (4) SaniTEE screens, blower assemblies, and central control panel. The MyFAST4.0 unit shall be situated within a 40,000 gallon (152 m3) minimum tank, as shown on the plans. Settling tank(s) equaling to 1 x daily flow must be used prior to MyFAST. Tank(s) must conform to local, state, and all other applicable codes. The contractor shall provide coordination between the MyFAST system and tank designer (supplier) with regard to fabrication of the tank, interconnecting piping, wiring, and similar items, installation of the MyFAST unit and delivery to the job site. The optional Biosolids Management System shall include a biosolids wasting pump and biosolids decant pump with jib crane, LIXOR 2.0 with blower assembly and control panel which will provide aeration to the biosolids storage zone. All tanks supplied by others. 2. OPERATING CONDITIONS The MyFAST 4.0 treatment system shall be capable of treating the wastewater produced by typical family activities (bath, laundry, kitchen, etc.) ranging from one hundred (100) to six hundred (600) persons and not to exceed 40,000 US Gallons per day (152 m3/d). 3. MEDIA The MyFAST media shall be manufactured of rigid PVC, polyethylene, or polypropylene and it shall be supported by the polyethylene insert. The media shall be fixed in position and contain no moving or wearing parts and shall not corrode. The media shall be designed and installed to ensure that sloughed solids descend through the media to the bottom of the tank. 4. BIOSOLIDS COLLECTION MANIFOLD A biosolids collection manifold will be provided which will be located below the MyFAST4.0. The biosolids collection manifold will consist of 4 PVC lateral pipes that are equally spaced under the MyFAST4.0 with orifices specifically designed to remove biosolids from the MyFAST zone. The 4 laterals will be connected into a PVC pipe header that will provide a single 8 inch discharge into the tanks Biosolids Pump Pit. 5. BLOWER The MyFAST4.0 unit shall come equipped with a blower capable of delivering 400 to 700 CFM [680 - 1190 m3/hr]. The blower assembly shall include an inlet filter with metal filter element. 6. REMOTE MOUNTED BLOWER The blowers shall be mounted outside the tank adjacent to the MyFAST zone on a contractor supplied concrete base. The blower elevation must be higher than the water level in the tank and above any normal flood level. A two-piece, rectangular housing shall be provided with tamper-proof screws. The 4 inch (100 mm) steel discharge air line and connections from the blower to the MyFAST 4 inch (100 mm) air header shall be provided and installed by the contractor. 7. ELECTRICAL/CENTRAL CONTROL PANEL All wiring must conform to code and provide the specified power to the blowers. Input power on 60Hz electrical system is 230/415 VAC, three phase, 119.4/62.1 Amps. Input power on 50Hz electrical systems 220/380 VAC, three phase 116.7/73.5 Amps. All conduit and wiring shall be supplied by contractor. The central control panel shall utilize a motor starter, overload, and DO NOT SCALE be housed in a NEMA 4 X enclosure. The control panel shall consist of a visual and audible UNLESS NOTED alarm to indicate loss of power to the blower. A manual silence switch is included.
DIMENSIONS ARE IN INCHES [CENTIMETERS] TOLERANCES 0.02 IN/IN [ 0.05 CM/CM]
lb
NAME DATE

MyFAST 4.0
SIZE DRAWING NUMBER

WEIGHT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

BIO-MICROBICS 2010

3/27/2009 DRAWN CHECKED PF 5/25/2010

Specifications 1 of 2
REVISED 5/25/2010 REV.

SHEET 5 OF 6

Specifications for MyFAST 4.0 Wastewater Treatment System

A biosolids wasting pump located in the biosolids pump pit will be included with the optional biosolids management system. This pump shall be capable of pumping 550 to 800 gpm [2082 to 3028 Lpm] at 20 ft. [6m] total dynamic head to the biosolids storage zone. The biosolids wasting pump will require a power supply from the panel to the pump. A field adjustable event timer will control the duration of the wasting time and the frequency of wasting on an event timer. The contractor is responsible for supplying power to the pump. OPTIONAL DECANT PUMP AND JIB CRANE A decant pump will be included to pump the supernatant from the biosolids storage ZONE into the MyFAST aeration zone. The submersible decant pump shall be capable of pumping 200 to 250 gpm [757 to 946 LPM at 20 feet [6m] of total dynamic head to the MyFAST aeration zone. The contractor is responsible for supplying power to the pump. The decant pump will be controlled by a manual start/stop controller. A jib crane will be provided for decant pump intake height adjustments to remove the supernatant from the biosolids storage zone. The jib crane will be designed to handle a lifting capacity of 500 Lbs. and a lifting range of 160 inches [305cm]. 9. GENERAL INSTALLATION INSTRUCTIONS All work must be done in accordance with local codes and regulations. Installation of the MyFAST4.0 shall be done in accordance with the written instructions provided by the manufacturer. An operation and maintenance manual shall be furnished which will include a description of system installation, operation, and maintenance procedures. Each FAST interconnecting insert weighs approximately 1300 pounds [590kg]. Four holes for lifting each FAST interconnecting insert are supplied. Spreader bars are to be used in lifting the inserts. Place spreader bars between lifting holes. For details refer to the Installation Manual. 10. FLOW & PIPE SIZING The MyFAST 4.0 has two (2) each six (6) inch discharge ports. Each of the two (2) discharge ports are provided with a standard six (6) inch effluent gasket. The maximum free or unrestricted flow with the two (2) each six (6) inch effluent pipes is 250 U.S. GPM (945 LPM) with a 2.0 design safety factor. MyFAST systems have been successfully designed, tested and certified receiving gravity, demand-based influent flow. When influent flow is controlled by pump or other means to help with highly variable flow conditions, then multiple dosing events should be used to maximize performance.
11. WARRANTY Bio-Microbics, Inc. warrants all new MyFAST models (MyFAST 4.0, 8.0, and 16.0) against defects in materials and workmanship for a period of one year after installation or eighteen (18 months) from the date of shipment whichever occurs first, subject to the following terms and conditions: During the warranty period, if any part is defective or fails to perform as specified when operating at design conditions, and if the equipment has been installed and is being operated and maintained in accordance with the written instructions provided by Bio-Microbics, Inc., Bio-Microbics, Inc. will repair or replace at its discretion such defective parts free of charge. Defective parts must be returned by owner to Bio-Microbics, Inc.s factory postage paid, if so requested. The cost of labor and all other expenses resulting from replacement of the defective parts and from installation of parts furnished under this warranty and regular maintenance items such as filters or bulbs shall be borne by the owner. This warranty does not cover general system misuse, aerator components which have been damaged by flooding or any components that have been disassembled by unauthorized persons, improperly installed or damaged due to altered or improper wiring or overload protection. This warranty applies only to the treatment plant and does not include any of the structure wiring, plumbing, drainage, septic tank or disposal system. Bio-Microbics, Inc. is reserves the right to revise, change or modify the construction and/or design of the MyFAST system, or any component part or parts thereof, without incurring any obligation to make such changes or modifications in present equipment. Bio-Microbics, Inc. is not responsible for consequential or incidental damages of any nature resulting from such things as, but not limited to, defect in design, material, or workmanship, or delays in delivery, replacements or repairs. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED. BIO-MICROBICS SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NO REPRESENTATIVE OR PERSON IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR TO ASSUME FOR BIO-MICROBICS, INC., ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS. DO NOT SCALE Contact your local distributor for parts and service.
UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS] TOLERANCES 0.02 IN/IN [ 0.05 CM/CM]
lb
NAME DATE 3/27/2009 5/25/2010

8. OPTIONAL BIOSOLIDS MANAGEMENT SYSTEM OPTIONAL BIOSOLIDS WASTING PUMP

MyFAST 4.0
SIZE DRAWING NUMBER

WEIGHT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

BIO-MICROBICS 2010 DRAWN

Specifications 2 of 2
REVISED 5/25/2010 REV.

SHEET 6 OF 6

CHECKED PF