Sie sind auf Seite 1von 6

CONFIGURABLE SAFETY RELAYS

TNT 35 Typical areas of application


Print and paper processing machinery in accordance with EN 1010 Power-operated windows, doors and gates in accordance with ZH 1/494 Storage installations in accordance with ZH 1/482 and DIN 15185/2 Textile machinery in accordance with VGB 76 or DIN ISO 11111 Packaging machinery in accordance with VBG 76 or prEN 415-2, 3 and 4 Meat processing machinery in accordance with VBG 79 Machinery used in the chemicals, rubber and plastics industries in accordance with VBG 22 Wood processing machinery in accordance with ZH 3.1 to 3.19 and ZH 1/56a

Guarding a wood processing center with SLSR 46B Single Light Beam Safety Devices and TNT 35 Test Monitoring Unit
TNT 35 is a Test Monitoring Unit for the periodic testing of "testable" optoelectronic protective devices. Both components, sensor and TNT 35, form an AOPD in accordance with IEC/EN 61496-1, -2. Up to 6 type 2 sensors can be connected to the TNT 35 via a series connection. In addition to testable Leuze electronic type 2 Single Light Beam Safety Devices, type 2 Single Light Beam Safety Devices of the MLD 300 series can also be connected. The machines functional sequence remains unimpaired by the periodic internal function tests.

TNT 35 p. 478

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

TNT 35
Important technical data, overview
Type in accordance with IEC/EN 61496 Performance Level (PL) in accordance with EN ISO 13849-1 Category in accordance with EN ISO 13849 Stop category in accordance with IEC/EN 60204-1 Supply voltage Response time Interval for periodic testing Max. number of type 2 sensors in series connection Safety-related switching outputs (OSSDs) Ambient temperature, operation Ambient temperature, storage Dimensions (W x H x D)

Type 2 PL d 2 0 24 V DC, 15% <20 ms 2s 6 (total response time of the sensor series connection, 60 ms) 2 relay outputs (NO) -20...+60C -30... +70C 45 mm x 99 mm x 113.6 mm

Functions
Test Monitoring Unit for periodic testing of type 2 sensors Multiple monitoring of type 2 sensors with series connection Start/restart interlock (RES), optionally with/without Static contactor monitoring (EDM), with/without optional "Safety on" signal output "Error" signal output

Features
Accessories

Special features
Constant cyclical testing every 2 s without process interruption of the machine function during the test 2 Safety Relay outputs with internal monitoring Selectable start and restart interlock status Selectable integrated contactor monitoring (EDM) LED indicators for all important functions and operating states Low space-requirement in the cabinet with compact construction

Ordering information Electrical connection Technical data Dimensional drawings Type 2 Single Light Beam Safety Devices

480 481 482 483 270

www.leuze.com/interfaces/

479
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Product Finder

Further information

Page

Glossary

Configurable Safety Relays

Safety Relays

Safety Command Devices

Safety Locking Devices

Safety Switches

CONFIGURABLE SAFETY RELAYS


Ordering information
TNT 35 Included in delivery: 1 connecting and operating instructions manual Functions: Periodic testing, start/restart interlock, contactor monitoring

Art. no. 50033058

Article TNT 35

Description Test Monitoring Unit

Safety-related switching outputs (OSSDs) 2 relay outputs

TNT 35 p. 478

480

We reserve the right to make changes 15-05_TNT_35.fm

2010 Leuze electronic GmbH + Co. KG

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

TNT 35
Electrical connection
TNT 35 connection example

+ 24V

+ 24V

-K1
w/ o RES

RES

L+ 1

L+ 1

-K2 -A1
1

-A2

-A3

14 15 16 22 23 24

21

13

29

31

MLD 300-T

MLD 312-R

TNT 35

State

6 Var. B Var. A

30

32

-K1 -K1 -K2 -K2

A1

A1

-K2

L0V PE

L0V PE

Test-berwachungseinheit TNT 35 Test Monitoring Unit with type 2 MLD 312 Multiple Light Beam Safety Device
Please observe the operating instructions of the components!

www.leuze.com/interfaces/
We reserve the right to make changes 15-05_TNT_35.fm

2010 Leuze electronic GmbH + Co. KG

481

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Product Finder

Glossary

Accessories

-K1

A2

A2

Configurable Safety Relays

Error

0V

0V

Safety Relays

+ 24V

OSSD

+ 24V

Start active

Test

Error reset

Safety Command Devices

Safety Locking Devices

Safety Switches

CONFIGURABLE SAFETY RELAYS


Technical data General system data
Performance Level (PL) in accordance with EN ISO 13849-1 Service life (TM ) in accordance with EN ISO 13849-1 Probability of a failure to danger per hour (PFHd) PL d 20 years 8.8 x 10-8 1/h With DC1 (ohmic load) With AC1 (ohmic load) With DC13 (inductive load) With AC15 (inductive load) Low load (20% nominal load) 2

Number of cycles until 10 % of the components have a failure to danger (B10d)

On request On request 10,000,000 (2 A, 24 V) 100,000 (2 A, 230 V) 600,000 (1 A, 230 V) 1,300,000 (0.5 A, 230 V) On request

Category in accordance with EN ISO 13849 Mean time to dangerous failure (MTTFd) in accordance with EN ISO 13849-1 DCavg Type in accordance with IEC/EN 61496 Stop category in accordance with IEC/EN 60204-1 Interval for periodic testing Max. number of type 2 sensors in series connection Supply voltage Response time Sensor response time for test request Protection rating Ambient temperature, operation Ambient temperature, storage Dimensions (W x H x D) Mounting Connection system Current consumption Safety-related switching outputs (OSSDs) Switching voltage, switching current (for OSSDs) Connectable safety sensors (AOPDs)

72.6 years (TNT 35), 69 years (TNT 35 AC) 94.4 Type 2 0 2s 6 (total response time of the sensor series connection, 60 ms) 24 V DC, 15% <20 ms Time window 0.5 60 ms IP 40 (only suitable for use in electrical operating rooms/cabinets with IP 54 minimum protection rating) -20...+60C -30... +70C 45 mm x 99 mm x 113.6 mm on 35 mm DIN rail Cable gland, up to 2.5 mm2 Approx. 200 mA without external load 2 relay outputs (NO) Max. 250 V AC, max. 4 A Type 2 Single Light Beam Safety Devices, see 270

482

We reserve the right to make changes 15-05_TNT_35.fm

2010 Leuze electronic GmbH + Co. KG

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

TNT 35
Technical data
Control inputs Receiver input Start/restart interlock (RES) Contactor monitoring (EDM) Control output Transmitter activation Signal outputs Safety on Safety with TNT 35/7-24V Error

pnp transistor output (high-active) pnp transistor output, 100 mA Potential-free relay contact pnp transistor output, 100 mA

Please note the additional information in the connecting and operating instructions and at www.leuze.com/interfaces.

Dimensional drawings

111

Sensor Start/active EDM OFF/ON

TNT35

99.0

TNT 35 Test Monitoring Unit Dimensions in mm Our 3D CAD models can be found under: www.leuze.com/3d-cad-models.

www.leuze.com/interfaces/
We reserve the right to make changes 15-05_TNT_35.fm

2010 Leuze electronic GmbH + Co. KG

483

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Product Finder

45

113.6

Glossary

Accessories

Configurable Safety Relays

Safety Relays

Safety Command Devices

Potential-free opto-coupling input (high-active), input current approx. 10 mA Potential-free opto-coupling input (high-active), input current approx. 10 mA Potential-free opto-coupling input (high-active), input current approx. 10 mA

Safety Locking Devices

Safety Switches

Das könnte Ihnen auch gefallen