OneU Unique Design :

OneU rack mount now is available from 1000VA

FEATURES:
• True on-line technology provides all power protection
• Cold start function (DC power on) • Pure sine-wave output with less than 3% THD
• Lightning and surge protection • Fully digitized microprocessor controlled
• Battery replacement warning • Short Circuit and overload protection
• Schedule shutdown & reboot • Advanced battery management (ABM)
• Hot swappable battery by user • Automatic battery charge in UPS off mode
• Emergency Power Off function • Automatic diagnostics & battery check
• Battery remain time display • RS-232 communication port with monitoring software
• LCD display front panel • Network/fax/modem surge protection
• Optional SNMP Card slot • History record of power failure events
• Wide input voltage range • UPSMON plus software monitoring
• Power factor correction • Extended back up time with battery pack
• Manual bypass setting • Optional Extension battery pack
• Free run mode setting • Load segmentation receptacles controllable
• EMI/RFI noise filter • High efficiency mode selectable
• Support USB communication • Fan speed auto control when loads varies
• Multiple language LCD display
• On line output voltage selected

Tower Model (With LCD Display) VGD-1000

19" Rack-Mount Model VGD-1000-RM

Capacity (VA) 1000VA

Capacity (W) 700W

100V/110V/115V/120V/127V 208V/220V/230V/240V

Load Load
Voltage/Range Voltage/Range
Capacity Capacity
INPUT Voltage
60 ~ 69V 0 ~ 40% 120 ~ 139V 0 ~ 40%

70 ~ 79V 0 ~ 70% 140 ~ 159V 0 ~ 70%

80 ~ 144V 0 ~ 100% 160 ~ 276V 0 ~ 100%

Frequency 50 / 60 Hz Auto Sensing

100V, 110V, 115V, 120V, 127V or 208V, 220V, 230V, 240V +/-
Voltage (on battery)
2% (Selectable Output Voltage)

Frequency (on
50 / 60 Hz +/-0.5%
battery)
OUTPUT
Transfer Time 0 ms ( On-Line)

Overload Recovery Auto transfer to UPS

High Efficiency > 95 %


Mode (AC to AC)

Line Mode > 86%

UPS Green Mode Energy saving function (No Load Shutdown)

UPS Design
On-Line / Fully digitized microprocessor controlled
Technology

Output Wave Form Sinewave

Harmonic Distortion < 3% of T.H.D. at linear load

Crest Factor 3:1

Surge Protection 120V (IEEE C62.41) / 230V (IEEEC61000-4-5 level 3)

Overload
PROTECTION & 125% for 1 minute and 150% for 10 seconds
Protection
FILTERING
UPS output cut off immediately or input fuse / circuit breaker
Short Circuit
protection

Visual Display UPS on(green), line-mode(green), battery mode(yellow),


(LED Model) bypass(yellow), fault(red)

Visual Display Input / output voltage, input / output frequency, on-line mode,
SYSTEM (LCD Model) back up mode, battery capacity, load level
DISPLAY /
Audible Alarm
WARNING Beep every 5 sec
(Battery Back-Up)

UPS Fault Continuous beeping sound and LCD display

Communication RS-232 Serial Port and USB

Type Sealed, maintenance-free lead acid batteries

DC Voltage (V)
36V / 12V7.2AH x 3
Battery (Tower )

DC Voltage (V)
24V / 6V7.2AH x 4 None
Battery (1U)

Typical Recharge
3 hours
Time to 90% Full

BATTERY Management Self-test, adjustable battery transfer points and alarm settings

Battery Protection Cut off without draining any current when battery is low

Cold Start (DC


YES
Start)

Back Up Time
(Full Load) 1U = 4 min

Back Up Time
(Half Load) 1U = 10 min

Input lnlet NEMA 5-15 (120V) / IEC 320 (230V)


PHYSICAL
Receptacles NEMA 5-15 (120V) / IEC 320 (230V)
Total Receptacles
(UPS+Surge / 6 (120V), 4 (230V)
Surge Only)

19" Rack-Mount 428 x 525 x 44 (16.9" x 20.7" x 1.7") 1U None


Dimensions mm
(inch)

Net Weight kg (lb)


171. (37.6)
Tower model

Shipping Weight kg
(lb) 18.9 (41.6)
Tower Model

Operating
0 - 40 deg C / 32 ~ 104 deg F
Temperature

Storage
-20 ~ 50 deg C / -4 ~ 122 deg F
Temperature

ENVIRONMENT Altitude 3,500 meters max

Audible Noise
(1 meter from < 40 dBA
surface)

Relative Humidity 0 ~ 95% humidity, non-condensing

Safety UL 1778, CE

CONFORMANCE EMC (EMS / EMI) IEC 61000-4, FCC Part 15, CISPR 22

Warranty policy Warranty policy may vary depends on region