Sie sind auf Seite 1von 2

1.

3 kW Wind Turbine System Specication Sheet


Wind is a naturally occurring and abundant resource and is one of the cleanest ways to produce electricity. Very little processing needs to be done to convert it into clean, free energy. Operation of our wind turbines produces no pollution with no emissions, excessive noise or waste heat by-products. Wind can be harvested with minimal impact on the environment, a very important factor in meeting our increasing energy needs. Synergy - Solar - Biomass - Diesel Generator - Hydroelectric - Geothermal Applications - Commercial and Industrial - Residential and Resort - Agricultural - Remote Communities - O-Grid Power - Institutional and Public Key Benets - Energy cost savings from wind generated power - No scheduled maintenance - Designed to reliably operate in harsh cold & hot climates - Operation creates virtually no environmental impact - Cost-eective and nancially viable - Warranty

Turbine Rated Power Output Energy Production* Type Generator Swept Area Blade Diameter Blade Material Total Turbine Mass Voltage/Phase @ Rated Power Current/Phase @ Rated Power Generator NEMA Rating 1.3 kW 200 kWh/month 3 blades, horizontal axis Gearless, brushless, permanent magnet 6.8 m2 2.9 m Fibreglass reinforced plastic 39 kg 125 Vac peak 3.6 Aac peak Class B, 2 HP

Life Expectancy > 25 years *5.0 m/s (18 km/h) average wind speed, Rayleigh Distribution, Sea Level elevation Operational Data Rated Wind Speed Start-up Wind Speed Furling Start-up Wind Speed Furling Method RPM at Rated Power Survival Wind Speed Survival RPM 11 m/s (39 km/h) 3 m/s (11 km/h) 10 m/s (36 km/h) Spring/hinge-based tilt-up 800 RPM 45 m/s (162 km/h) 1,400 RPM

Conversion Table m/s 4 6 8 10 12 18 25 45 km/h 14 22 29 36 43 65 90 162 mph 9 13 18 22 27 40 56 101

A Revolution in Wind Energy


Inverter Type Input Power Rating Electrical Input Rated Input Voltage Rated Input Current Output Voltage Max Output Current Power Factor at Output Certications Enclosure Weight Size Grid-tie 1350 W Three-phase 125 Vac peak/phase 3.6 Aac peak/phase 120 Vrms True Sine Wave 10 Arms True Sine Wave >0.99 CSA 22.2 #107.1 and UL 1741 9 kg 300 mm x 300 mm x 100 mm System Power Curve Wind Speed Power Out (W): (m/s) Grid-tie 4 5 6 7 8 9 10 11 12 13 58 127 241 429 673 914 1200 1200 1200 1200 Power Out (W): Battery Charger 74 155 279 472 713 965 1289 1500 1500 1500

Tower Tower Type Installation Method Foundation Number of Sections Tower Mass Max Lateral Load at Mast Max Vertical Load at Mast Survival Wind Speed* Tower Height to Nacelle Engineered free-standing steel truss Gin pole; no crane required 3 m3 reinforced concrete 4 x 3 m (10) sections + 2m mast 14.5 m (48) 165 kg 2200 N (500 lbs) 440 N (100 lbs) 45 m/s (162 km/h)

Annual Energy Production Wind Speed kWh/year: (m/s) Grid-tie 4 4.5 5 5.5 6 6.5 7 1221 1781 2443 2766 3331 3610 3877

kWh/year: Battery Charger* 1393 2016 2813 3365 4205 4859 5413

*With 2200 N (500 lbs) loading at mast tip

7.5 4047 6068 * Does not include eciency of o-grid inverter

Regional Raum Certied Dealer

Toll Free. 1-877-946-3979 Ph. (306) 651-1476 sales@raumenergy.com www.raumenergy.com

3718A Millar Ave Saskatoon, SK S7P 0B1 Canada