Unit No.

Fukushima Daiichi Status Summary - 0830 EDT 0414/2011 - Update


400 assemblies-damaged; RPV pres: (ch A=29.44_psig, ch B=71.2 ,psig) (TEPCO 4/4); RPV level: -1/2 TAF (NISA 4/3); fresh water inject. 26.4 gpm, (TEPCo 4/4) via fire ext. line using temp. elect. pump (IAEA 4/2); Vessel temp: Btm Head 113.40C+-+, FW nozzle: 243.10C4., (TEPCO 4/4), On offsite AC power - CR Lighting for U-1, 2, 3 & 4 (JAIF 4/1); instr pwr on for U-1, 2 & 4 (IAEA 3/29); Primary: damage suspected, slow leakage. D/w pressure: 7.8,ipsig (TEPCo 4/4) D/w 3830 rem/hr (TEPCo 4/4). Losing 10-30% drywell volume/day (Site Team 4/2) Torus press. 8.5 psig (TEPCo 4/4) Torus: 1340 rem/hrl, (TEPCo 4/4). Secondary: severe damage from H, explosion. 292 bundles (GEH); Temp: 100C (3/31 0815JST USFJ), LVL: unconfirmed, Periodic spray using pumper (DOE 4/3) 548 assemblies - damaged; RPV pres: -16.0l, psig (NISA 4/4); RPV level: 2/3 TAF (IAEA 4/3); freshwater injection 35.2 gpm+-+ (NISA 4/3) via fire ext. line using temp. elect pump (IAEA 4/2) Vessel temp: Btm Head 137oCt (Site Team 3/31), FW nozzle 140.30C (NISA 4/4), On offsite AC power (NISA 4/3) Primary: damage suspected. D/w pressure .53 +-,psig (TEPCo 4/4) 3340 rem/hrl, (TEPCo 4/4) Torus: 91 rem/hr4, (TEPCo 4/4) Secondary: panels removed from side of Rx bldg reducing H 2 build-up. 587 bundles (GEH); Temp: 48.OOC (TEPCO 4/4); Level: full, fresh water injection continues (DOE 4/3) 548 assemblies - damaged; RPV pressure: -113.0,4, psig (TEPCo 4/4); RPV level: - 2/5 TAF (IAEA 4/3) Rad levels indicate fuel covered (site team); freshwater injection 30.8 gpm4., (TEPCo 4/4) via fire ext. line using temp. elect pump (IAEA 4/2) Vessel temp: Btm Head 114.1Ct ; FW nozzle: 89.80C1 (TEPCo 4/4). On offsite AC power (NISA 4/3). Primary: RST suspects failure. D/w pressure: 0.82 psig, Torus press. 10.7 psig (TEPCo 4/4). 2150 rem/hrJ,, Torus: 87 rem/hr4l, (TEPCo 4/4) Secondary: severe damage from H 2 explosion. 514 bundles (GEH) - damage suspected (JAIF 3/28); Temp: 56C (JAIF, 4/3); Level: fresh water spray periodically (DOE 4/3). 1331 bundles in SFP (GEH & NISA) Temp & Level: 42 C (JAIF 4/3). On offsite AC power (DOE 4/3). Secondary contain. severe damage-H2 explosion AC 548 assemblies - no damage; RPV intact; temp 29.90CL, (TEPCo 4/4); Cold shutdown at 1430 JDT 3/20 (NISA); Offsite power supplying house loads (IAEA 3/28) injection via normal make-up water (IAEA 3/31); 946 bundles (JAIF); Temp: 36.1 0C'I (TEPCo 4/4); Cooling capability recovered (JAIF 4/1) 764 assemblies - no damage; RPV intact; Temp 48.0 0Ct (TEPCo 4/4); Cooling using RHR; Cold shutdown at 1927 JDT 3/20 (NISA); offsite AC power to house loads (IAEA 3/28); injection via normal make-up water (IAEA 3/31); SF Pool 876 bundles (GEH); Temp: 21.504, (TEPCo 4/4); Cooling capability recovered (JAIF 4/1) 6,000 bundles (GEH) maintained at 32.0C4, (TEPCo 4/4); normal cooling started 1805 JDT 3/24/2011 (NISA)

Priority

1 Containment SF Pool Core 2 Containment SF Pool Core 3 Containment

SIF Pool 4 SF Pool Core SF Pool 6

Common SF Pool Notes

Summary Sheet Notes:


Basis for Assigned Priority to Units
PRIORITY 1 - Unit 1, maintaining containment is high priority

PRIORITY 2 - Unit 2, containment damaged


PRIORITY 3 - Unit 3, Primary containment may be intact. However,

flooding in turbine building contains 1-131


PRIORITY 4 - Unit 4, due to the condition of its spent fuel pool PRIORITY 5 - Unit 5, Higher priority, temperature is 37 C (increased

slightlv) vs. 22 C in Unit 6. Difference not significant. Cooling being maintained. PRIORITY 6 - Unit 6, SPF cooling being maintained Common SFP is low priority, adequately maintained.