Meriam Instrument is a leading manufacturer of instrumentation for the precise measurement of flow, pressure and level. As shown below, the product line includes primary elements and indicators to serve both calibration and process measurement applications for pressure, flow and level applications.
MICROMANOMETER SMART MANOMETER MERICAL MERICAL II LAMINAR FLOW ELEMENTS / SYSTEMS MANOMETERS - LIQUID FILLED AND DIGITAL BELLOWS DP GAUGES BOURDON P GAUGES DIGITAL P GAUGES SMART GAUGES SMART TRANSMITTERS
Measurements Indicators
PROCESS PRESSURE
PROCESS FLOW
LAMINAR FLOW ELEMENT ACCUTUBE AVERAGING PITOT ORIFICE PLATES & FLANGES FLOW SYSTEMS
Measurement Type
DP P gauge P absolute
MANOMETERS BELLOWS DP GAUGES SMART GAUGES SMART TRANSMITTERS LAMINAR FLOW SYSTEMS, FLOPAC, SMV TRANSMITTERS
Measurements
Indicators
PROCESS FLOW
DIRECT HEAD ON VENTED TANKS BUBBLER SYSTEMS FOR VENTED OR PRESSURIZED TANKS
DP P gauge
Since 1911 Meriam products have been used around the world in applications as diverse as chemical processing, oil drilling rigs, respiratory therapy and laboratory experiments. Originally a family run business, Meriam became a Scott Fetzer Division in 1969. Other divisions in the Scott Fetzer Corporation include Kirby Vacuum Cleaner, World Book, Campbell Hausfeld, Adalet and several others. Since 1986, Scott Fetzer is a wholly owned subsidiary of Berkshire Hathaway. Today, Meriam offers many more industrial instruments than ever before, most with versatility not available elsewhere. With design, manufacturing and application support headquartered in Cleveland, Ohio, Meriams ability to solve measurement problems is extensive and our technical data is yours for the asking. This brochure will provide an overview of the Meriam product groups. For more information on specific products, request our Product Bulletins containing detailed data. Product Bulletins are available directly from Meriam or from our field representatives conveniently located throughout the United States and the world. We invite your inquiries and are ready to help in solving your measurement and calibration problems.
Table of Contents
Meriam Product Groups
Introduction Table of Contents
Meri-Cal II
Portable, multifunction, multi-sensor Calibrator for pressure transmitters. 0.025% F.S. accuracy. Sensor ranges from 20" H2O to 2000 PSIG, 2000 mm Hg Abs, 50 volts/mA. Data Logging option.
Meri-Cal (original)
Portable, multifunction Calibrator for pressure transmitters. 0.05% Reading, 1 count accuracy. Sensor ranges of 200" H2O and 2000" wc, 30 volts/mA
Page 6
Smart Manometer models 350,351 and Precision Absolute Manometer model 355
Portable,Digital Manometer, 0.025% FS accuracy. Ranges 20" H2O to 2000 PSIG, 2000 mm Hg A
Page 16-17
Page 18-19
Manometer Accessories
Pressure / vacuum sources and variators, Sight Feed Bubblers, Line Traps, Check Valves, Seal Pots
Manometers
Liquid filled U-tubes, Well types, Inclined tubes and Micromanometers for measuring pressure and vacuum. SWP to 500 PSI. Accuracy is typically 1 2 of smallest graduation.
Page 24-27
Page 28-38
Meri-Cal II
Model 3600 & 3610 Pressure Calibrator
Model 3600 Meri-Cal II is a microprocessor based pressure calibrator with 5 digit resolution and NIST traceability. Two pressure sensors and one electrical sensor installed in the Meri-Cal II will allow measurement of differential and static pressure, plus current and voltage in one unit. Any two of these measurements are displayed on a 4 line by 20 character alphanumeric display, making calibration of transmitters and transducers easy. The Model 3610 Meri-Cal II incorporates a convenient Data Logging mode and on-board memory to provide calibration documentation at the stroke of a key. Calibration procedures can be set up quickly using the Windows 95 Data Logging Program. Up to 20 PC Calibration files of up to 20 points each can be downloaded from a PC. This allows the 3610 to prompt the user with required calibration points. Another 20 Manual Calibrations files can be stored directly through the keypad.
Specifications
Approvals: CE compliant (Optional) Display: 4 line x 20 character alpha-numeric 5 full digit resolution NIST traceability: NIST certificate supplied for all models. Power: 9-volt alkaline battery with user enabled automatic shut-off. Optional 9 volt lithium batteries can also be used and are recommended below 32 F (0 C). Temperature: Storage: -40F to 140F (-40 to 60C) Operating: 23F to 122F (-5 to 50C) Process connection: 1/8 female NPT, 316ss Media compatibility: Non-isolated sensor (DN) for clean, dry, non-corrosive gases. Isolated sensor (GI and AI) for fluids compatible with 316ss. Pressure limits: Twice range on GI/AI units. Twice range on DN units when pressurized on high side only and 150 PSI (10.5 Kg/cm2) static when applied to both sides of the sensor simultaneously. Enclosure: 30 ounces. (8.5L x 5.2W x 3.0D) ABS plastic case Accuracy: Pressure sensor 0.05% of F.S. or optional 0.025% of F.S. Electrical measurements 0.025% of F.S. Accuracy includes all effects of linearity, repeatability, hysteresis and temperature over the range 23F to 122F
Meri-Cal II
Model 3600 & 3610 Pressure Calibrator
3610 Features (Additional to 3600)
Memory - Non-volatile data-logging memory for 40 calibration files with up to 20 points per file. PC Data Logging Mode - prompts user to follow calibrtion procedures downloaded from a PC (Requires Optional Software). Stores AS FOUND and AS LEFT data in memory. Manual Data Logging Mode - field defined data logging for transmitter or transducer calibrations or documentation of local indicators or flow computers. DB-9 serial connector - used for downloading calibration files from a PC to the 3610 and for uploading stored calibration results to the PC (Requires Optional Software)
Ordering Information
MERI-CAL II (includes current / voltage sensor): 3600 Select one or optionally two sensors from selection below. Order same accuracy for units with two sensors. SENSORS:
.05% DN0200 DN2000 GI0020 GI0200 GI2000 AI2000 0-200 H2O 0-2000 H2O 0-20 PSI 0-200 PSI 0-2000 PSI 0-2000 mm Hg .1% Differential Differential Gauge Gauge Gauge Absolute DN0020 .025% DN0200 DN2000 GI0020 GI0200 GI2000 AI2000 0-200 H2O 0-2000 H2O 0-20 PSI 0-200 PSI 0-2000 PSI 0-2000 mm Hg Differential Differential Gauge Gauge Gauge Absolute
3610 Adds onboard memory card and PC Data logging to the model 3600(Requires software and cable- see accessories)
0-20 H2O
Differential
To Order a Meri-Cal II with 200 Differential and 2000 PSI sensor with .025% accuracy. The order code is as follows: 3600-DN0200-GI2000-025 (add -025 extension for accuracy). Consult factory or your local Meriam Representative for Pricing
MERI-CAL II MODEL 3610 DATA LOGGING and COMMUNICATIONS SOFTWARE for PCs
The Data Logging and Communications Software for the Meri-Cal II is Windows 95 compatible. Features for the program include: SET TIME button to synchronize the Meri-Cal II real time clock with the PCs. DATA ACQ provides automated data acquisition (10Hz rate) using the PC with the Meri-Cal II. The Meri-Cal II Model 3610 will function as a data logging calibrator for pressure and electrical signal in the PC Data Logging Mode. CREATE CAL FILE facilitates the uniform creation of individual calibration files for each transmitter or transducer ID number. After entering a Serial/Tag # of up to 15 characters, Channel 1 and 2 Sensors are defined by clicking on the sensor type and desired units for each. The software allows up to 20 PC Calibration and 20 manual (20 points each) calibration files to be uploaded to the 3610. SEND PC CAL FILES downloads selected files to the Meri-Cal II. RECEIVE PC (and MANUAL) CAL FILES uploads stored calibration data from the Meri-Cal II to the PC. PRINT commands allow printing of calibration data previously uploaded to the PC.
The Meri-Cal II guides the user through the calibration procedure. The PC interface option allows for the display of PREV: the most recent as left data, FOND: the present as found data, and NOML: The desired present point to calibrate as programmed through the PC interface. With a simple keystroke this information is stored in non-volatile memory. The Meri-Cal II is then interfaced with the host PC for long-term information storage and printing of calibration certificates.
5
Media compatibility: Non-isolated sensor for clean, dry, non-corrosive gases. Auto Zero: A push of a button automatically establishes zero. There is no need to compute compensation factors for local gravity, temperature, or head difference due to the location of the tester vs. the unit under test. Engineering units: in H2O at 20C, cm H2O, PSI, in Hg at 0C, mm Hg, Kg/cm2, kPa, mBar and user scaled. Resolution: Auto-ranging for optimal accuracy and resolution of the display for both pressure and electrical inputs. Electrical Measurement: Voltage: 0 to 30 Vdc Current: 0 to 30 mAdc Accuracy: Pressure: 0.1% of reading, 1 count, Voltage/Current: 0.1% of reading, 2 counts. Optional 0.05% of reading, 1 count on pressure sensors. Accuracy includes the combined effects of linearity, hysteresis, repeatability and temperature over the calibrated range.
INCHES MM
LP models measure gauge pressure only. DP models can be used to measure differential pressure, gauge pressure and vacuum. * For CSA approved models change the I suffix to C For CENELEC approved models change the I suffix to E
Smart Manometer
Digital Manometer
Meriam Instrument's 350 Series Smart Manometers are the first pressure measuring instruments with accuracy of 0.025% of F.S. at truly low prices. They are microprocessor-based pressure sensing devices that can measure gauge, differential, absolute or vacuum pressure. The displays can read out in any of eleven engineering units and can also be scaled to special user units for pressure. Differential models offer a flow function to display square root flow rate in user defined units. An adjustable damping feature minimizes the effects of pulsating pressures. A Min/Max function captures the extremes of pulsating or other varying pressure signals and a Hold button can freeze the display at any point of interest.
Model 350 Smart Manometer Test Gauge Accuracy *: 0.05% of F.S. 0.1% of F.S. 20" H2O differential range only Range: 20" H2O, 200" H2O and 2000" H2O DP 20 PSIG, 200 PSIG and 2000 PSIG Gauge 2000 mm Hg Absolute
Model 351 Smart Manometer Calibrator Accuracy *: 0.025% of F.S. Range: 200" H2O, 200" H2O and 2000" H2O 20 PSIG, 200 PSIG and 2000 PSIG 2000 mm Hg Absolute
355 Ordering Information 355-AI0900 355-AI2000 0-900 mm Hg Abs. (Includes soft vinyl carrying case) 0-2000 mm Hg Abs. (Includes soft vinyl carrying case)
A900020-90772
Range
0-20 0-200 0-1000 0-10 0-30 0-100 0-50 0-500 0-2000 0-7 0-30 0-1500 0-60
Units
in H2O in H2O in H2O psi psi psi mbar mbar mbar bar psia mm Hg A in Hg A
Resolution
0.01 0.01 0.1 0.001 0.01 0.01 0.1 0.1 0.1 0.001 0.01 0.1 0.01
H2O and Hg ranges are supplied referenced to 20 C (68 F) and 0 C (32 F) respectively.
10
Ordering Information 2110P Smart Pressure Gauge Sensor Type: DN0020 DN0200 DN2000 GI0020 GI0200 GI2000 AI2000 0-20"H2O 0-200" H2O 0-2000" H2O 0-20 PSI 0-200 PSI 0-2000 PSI 0-2000 mm Hg Mounting options: 01 Panel Mount (standard) 02 2" Pipe Mount 03 Portable Handle / Bench Stand Power/Output options 1 110/220 VAC, 24 VDC/RS-232C,and SPDT Relays (Standard) 2 Batteries / No Outputs 3 24 VDC /4-20 mA, RS-232C 4 Batteries w/I.S. approval 5 Batteries w/CE approval 6 Code 3 w/CE approval 7 24 VDC/ 1-5 VDC, RS-232C, CE approval
Example: 2110P with 200" H2O Differential pipe mount and Battery Pack 2110P DN0200 02 2
11
Example: 2110L with 200" H2O Differential pipe mount and 4 to 20 output 2110L DN0200 01 3
percent, kilograms, cubic meters, in. H2O and user defined units. Minutes or hours time constant can also be displayed Sensor Type: DN0020 DN0200 DN2000
Mounting options: 01 Panel Mount (standard) 02 2" Pipe Mount 03 Portable Handle / Bench Stand
Power/Output options 1 110/220 VAC, 24 VDC/RS-232C,and SPDT Relays (Standard) 2 Batteries / No Outputs 3 24 VDC /4-20 mA, RS-232C 4 Batteries w/I.S. approval 5 Batteries w/CE approval 6 Code 3 w/CE approval 7 24 VDC/ 1-5 VDC, RS-232C, CE approval
Example: 2110F with 20" H2O Differential Panel mount and 4 to 20 output 2110F DN0020 01 3
12
Accuracy: 1% of Full Scale at calibrated temperature. Temperature effect: 0.1% per F. Display: 4.5 digit LCD (0.4" character height), Low battery indicator. Power: One 9 volt alkaline battery included, automatic timeout to conserve battery life. Enclosure: Custom molded ABS plastic housing. Engineering Units: Available in either PSIG, Bar or kg/cm2. Specify when ordering. Over-Pressure Limits: Twice the full scale range Weight: 7 ounces Certifications: NIST Certificate optional. CE and Intrinsically Safe/CSA pending Field Calibration: Zero and span adjustment potentiometers are accessible from the backside of the case.
Media Compatibility: Isolated sensor for liquids or gases compatible with 17-4 PH stainless steel. Process Connection: 1/4" male NPT Temperature: Storage: -4 F to 140 F (-20 C to 60 C) Operating: 32 F to 122 F (0 C to 50 C)
Dimensions
13
The MERIGAUGE digital pressure gauge from Meriam Instrument successfully addresses the modern demands of process pressure measurement. Pressure ranges are available to 6,000 PSIG at standard accuracy of 0.25% of Full Scale and optional accuracy of 0.10% of full scale. A combination gauge that can be used for positive pressure measurements and vacuum measurements is also available. The standard gauge is powered by two 9 volt alkaline or lithium batteries. Externally powered units are available. The pressure display is a 4 12" digit LCD with 0.6" high numerals. Each gauge includes 12 field selectable engineering units. The selectable units include PSIG, feet of water, inches of water, inches of the mercury, Bar, millimeters of mercury, kilopascals and user configurable units. In addition to numeric pressure indication, visual indication of the pressure is represented by an adjustable vertical bar graph on the left side of the display. Other standard features include Min/Max query, Zeroing, selectable Damping, selectable program Lock-out, adjustable display shutoff and field recalibration and adjustable display shutoff (for battery powered models). The housing is 304 stainless steel and NEMA 4 rated. Wetted components are 316 stainless steel for compatibility with many process fluids. Process connection is via a 14" MNPT 316 stainless steel stem. Typical applications are instrumentation and control in the process industries, hydraulics, pneumatics, industrial gases and OEMs. Options such as panel mounting, 24 Vdc powered units, 4 to 20 mA output, adjustable SPDT relay outputs, and various style diaphragm seals add to the versatility of the MERIGAUGE.
Y=
ZZ=
Standard Features
SELECTION OF ENGINEERING UNITS: PSIG, Ft. H2O, In. H2O (60 F, 20 C, 4 C), In. Hg, Bar, mm Hg, kPa, & user selectable units FIELD RECALIBRATION: Recalibration can be done at any time using an accurate standard pressure reference. SHUTOFF TIMER: (available on battery powered units) Selectable from off to 50 minutes. 24 VDC POWERED UNITS: External powered units for extended gauge operation and for gauges with output options. Compliance voltage: 17 VDC to 30 VDC. Intrinsically Safe (CSA) and CE APPROVAL: Intrinsically Safe/CSA approval for use in Class 1, Division 1, Groups A,B,C,D environments (battery units only, others pending). CE approval for use in the European markets. 4 to 20 mA or 1-5 VDC OUTPUT: Provides remote pressure monitoring. Fully adjustable throughout the gauge full scale range. Two wire configuration with a 6 foot pigtail and four wire configuration available for 4-20 mA. Four wire configuration for 1-5 VDC. MIN/MAX: Capture and display pressure extremes. DAMPING: Provides a stable pressure indication by averaging pressure measurements. Selectable from off to 50 seconds. BARLo & BARHi: A user scalable Bar Graph for visual indication of any pressure range. Default is 0 to100% of full scale range.
Options
SPDT RELAY OUTPUTS: Provides two adjustable SPDT relays that can be integrated in a control circuit to activate an external device such as a warning light, valve, solenoid, etc... Adjustable throughout the gauge full scale pressure range with adjustable deadband. Relay contacts are rated for 0.5 Amp @120 VAC and 1 Amp resistive @ 30 VDC. PANEL MOUNTING: Provides integral panel mounting bracket with rear pressure connection. DIAPHRAGM SEALS: Various sizes and styles of diaphragm seals including threaded, flanged and sanitary provide gauge to process isolation. Sanitary diaphragm seals are available for food and pharmaceutical applications.
PIPE MOUNT
Dimensions
PANEL MOUNT
15
Meriams 1500 Digital Transmitters are for high accuracy applications for OEMs, on manufactured skids, in process control systems and plant instrumentation. RS-485 communications allows for easy configuration using a PC or laptop computer. The RS-485 addressable interface allows up to 32 devices to be networked together. Optional 1-5 Volt or 4 - 20 mA outputs are also configured from a PC or laptop. 0.025% of URL (Upper Range Limit). Absolute, gauge and differential pressure sensors. 316SS isolated sensors for wet/corrosive process. Cost saving, non-isolated sensors for gas service. No temperature effect on RS-485 output from 23 to 122 F.
seconds NIST Traceability: NIST certificate supplied with all models. Temperature Range: Storage: -40F to 140F (-40C to 60C) Operating: 23F to 122F (-5C to 50C) Process Connections: Pressure: 1/8" female NPT, 316ss Electrical: DB-9 Media compatibility: Non-isolated Differential sensor (DN) for clean, dry, non-corrosive gases. Isolated Gauge and Absolute sensor (GI and AI) for fluids compatible with 316ss.
Absolute (GI and AI) units. Twice range on Differential (DN) units when pressurized on high side only and 150 PSI (10.5 Kg/cm2) static when applied to both sides of the sensor simultaneously. Engineering units: cm H2O, in H2O (at 39.2, 60 and 68F), mBar, Bar, mm Hg, in Hg at 0C, PSI, kPa, Kg/cm2 and user scaled. Enclosure: 2" x 4" x 4" NEMA 12 Aluminum Housing Mounting: Standard transmitter secures by pressure connections. Optional mountings are DIN rail clip or surface/wall mount flange. Weight: DN units are 1 lb. GI & AI units are 2 lb.
16
0.025 % of URL (0.1% 20" sensor) 0.05% of URL. 0.125% on 20" sensor 0.125% span @ 4:1 turndown of URL 1 - 5 VDC 0.05% of URL 0.125% on 20" sensor (or 0 - 5V) 0.125% span @ 4:1 turndown of URL Output Temperature Effect: Digital Output: No temperature effect from -5 C to 50 C Analog Output: .005% of span / C Long Term Stability: 0.1% URL per year
RS-485 4 - 20 mA
RS-485 (standard): Half Duplex, 3 wire- TR-1, TR-0, and Signal ground. 9600 baud, 1 start bit, 1 stop bit and no parity. External power of 7 to 32 VDC (40 mA max). Multi-drop addressing with up to 32 devices maximum per RS-485 segment. RS-485 repeaters for additional segments. 4-20 mA (optional): 2 wire current loop. 17 to 32 VDC for loop supplied 4-20 mA. 1-5V (or 0 - 5V) (optional) : 4 wire, 17 to 32 VDC powered.
1500 Digital Transmitter Digital Communications RS-485 PROGRAMMING: Pressure zero set Reset factory zero Analog output span and offset factor set Damping factor set Engineering unit selection Multi drop address selection 1500 Transmitter Accessories/Options: RS-485 interface devices Process connection adapters Electrical connection adapters System setup software Simultaneous digital communications and analog outputs
1500 Digital Transmitter Ordering Information DN0020 0-20" H2O Differential DN0200 0-200" H2O Differential DN2000 0-2000" H2O Differential GI0020 0-20 PSI Gauge GI0200 0-200 PSI Gauge GI2000 0-2000 PSI Gauge AI2000 0-2000 mm Hg Absolute AI0900 0-900 mm Hg Absolute
Please Specify the Model Number and Sensor Type. Example is based on a Model 1500 with a 200" H2O Differential sensor 1500DN0200
17
18
1124 4-1/2"
1126 6"
1224 4-1/2"
1226 6"
1226X 6"
1126P-2 6"
PROCESS CONNECTIONS 1/4" NPT 1/4" & 1/2" NPT 1/4" & 1/2" NPT 1/4" & 1/2" NPT
CENTERPLATE Brass Steel or Brass (500 SWP only) 316 SS, Steel or Brass (500 SWP only) 316SS
STATIC WORKING PRESSURE 500 or 1000 PSI. 1500, 3000 or 6000 PSI 1500, 3000 or 6000 PSI 1500, 3000 or 6000 PSI
BELLOWS
Beryllium Copper (30" W.C. Minimum--60 PSID Maximum) 316 Stainless Steel (50" W.C. Minimum--500 PSID Maximum) Monel (50" W.C. Minimum--60 PSID Maximum)
MOUNTING FLUSH PANEL using indicator case for mounting. WALL or 3/4" NPT using universal mounting bracket PIPE SADDLE or WALL using "H" mounting bracket and 2" U-Bolts. STANDARD FEATURES 0.75% FS for ranges 50" WC and greater; 1.5% FS for ranges less than 50" WC. Simple zero, span and linearity adjustment (field calibration). Temperature compensation for varying ambient. NEMA 4, Die-cast aluminum indicator case. Built-in pulsation dampening (field adjustable). 270 pointer travel for improved resolution. Break-resistant acrylic viewing window. Over-range protection. Special scales. Square Root Linear Tank Non Linear Red set pointer. Bellows fill fluids. Shock and vibration modifications. Personalized I.D. tags. LOX cleaning. Diaphragm seals and capillary tubing. CE approved models. Valve manifolds and piping. Shatterproof glass viewing window. CSA approved 1224 and 1226 models. Anti-Parallax Mirror dial. Special process connection sizes and locations. Stainless steel indicator housings and bezel rings. Special relays for 1220 series models. NACE MR-01-75 modification.
OPTIONS
19
Model 132334 Bourdon Tube Process Pressure Gauges These industrial type 4 12" process gauges are suitable for corrosive environments where the fluid medium is compatible with 316SS and not prone to clotting. The indicator case is available with optional liquid fill for severe vibration service. Solid front, blow-out back meets safety requirements of ASME B40.1. Lower mount stem and lower back stem process connection are available in 14" or 12" MNPT. Optional panel mounting kit is also available. Accuracy: +0.5% of FS (ASME B 40.1 Gr 2A) Ranges: Vacuum / Compound -30" HG / 0 / 200 PSI Pressure from 15 PSI to 30,000 PSI Working Pressure Range: Stable working pressure: 0.75 x full scale value Pulsating pressure: 0.90 x full scale value Short time over-pressure: 1.30 x full scale value Operating Temperature: -40 to 140F (-40 to 60C) Media: -40 to 212F (-40 to 100C) Case: Black reinforced thermoplastic, rear flange lugs 132354 Bourdon Tube Stainless Steel Pressure Gauges - Field Repairable These gauges are suitable for most process medias that are compatible with 316 St. Stl. wetted parts and are not prone to clogging the gauge's pressure system. St. Stl. case can be ordered liquid filled to dampen the pointer and lubricate movement. Bayonet-type bezel ring allows easy access to gauge movement for re-calibration or pointer adjustment. 2 12" & 4" dial sizes. 14" or 12" MNPT connections.
Accuracy: 2 12": + 1.5% of span, 4": + 1.0% of span Ranges: Vacuum / Compound to -30"HG / 0 / 200 PSI Pressure from 15 PSI to 15,000 PSI Working Pressure Range: Stable working pressure: 0.75 x full scale value Pulsating pressure: 0.90 x full scale value Short time over-pressure: 1.30 x full scale value Operating Temperature: -40 to 140F (-40 to 60C) Media: -40 to 212F (-40 to 100C) Case: 304 stainless steel with vent plug and stainless steel bayonet ring.EPDM o-ring between case and connection (4"); Welded case / socket connection (2 12") 132140 Bourdon Tube Pressure Gauges -Forged Brass Case with Copper Alloy Wetted Parts Heavy-duty, glycerine filled pressure instrument for stability and long service life. Offers superior service where pulsation or vibration exists. Compatible with all medias that do not clog connection port or corrode copper alloy. 2 12" and 4" dial sizes. 14" or 12" MNPT connections. Accuracy: 212": + 1.5% of span, 4" + 1.0% of span Ranges: Vacuum / Compound to -30"HG / 0 / 200 PSI Pressure from 10 PSI to 10,000 PSI Working Pressure Range: Stable working pressure: 0.75 x full scale value Pulsating pressure: 0.67 x full scale value Short time over-pressure: 1.00 x full scale value for 4" size, 1.30 x full scale value for 212" size Operating Temperature: -4 to 140F (-20 to 60C) Media: 140F (+60C) max. soldered tube 212F (+100C) max. brazed tube
20
Accessories
They are rated at 100 PSI and 50 PSI respectively. Either a ring type or strap type configuration is available for securing the bowl to the head.
Hand Pumps
These are available in 2 models, Pressure or Vacuum. The pressure pump generates a positive pressure up to 145 PSIG, while the vacuum pump generates a vacuum of 650mm Hg. Both units feature a needle bleed valve and a multi-turn vernier, which provides precise adjustment. Connections are 1/8" FNPT.
Line Traps
Line Traps are an inexpensive means to keep manometers and indicating fluids clean and are recommended for all installations. When installed in the line ahead of the manometer they permit entrained solids to settle out before they reach the manometer. When used with gases or vapors they trap moisture.
Return Wells
These are stainless steel and for use on manometers with operating pressures up to 500 PSIG. The indicating fluid is trapped during Manometer over pressure. Fluid will drain back into the Manometer when normal pressure is returned.
Seal Pots
Meriam Seal Pots are used to provide a constant liquid head on each side of a flow meter involving steam or other condensable vapors. They also isolate the instrument from the process with a sealing liquid. All Meriam Seal Pots are fabricated from grade A seamless steel pipe. Each unit is cold hydraulic tested to over twice its rated working pressure. All connections are 1/2" NPT furnished with solid steel plugs. The finish is red oxide primer.
21
Manometer
Meriam Manometers have many advantages in this age of technology because of their inherent accuracy and simplicity. Manometers are unique in being both pressure measurement instruments and standards for calibration of other instruments. Once considered solely a laboratory instrument, the manometer is today commonly used in production applications to measure pressures ranging from as high as 100 inches of mercury to the lowest vacuums of space. U-Tube Manometer The U-tube manometer is the basic and most widely used style of manometer. The Meriam U-tube manometer is a versatile, economical instrument for the measurement of pressures, vacuums or differential pressures. Pressure measurements are accomplished by balancing a vertical head of indicating fluid with the pressure to be measured. There are no cams, gears, or levers to operate in the manometer. This allows the U-tube manometer to be recognized by NIST as a primary standard due to its inherent accuracy and simplicity of operation. Meriam U-tube manometers are constructed of a ridged cast aluminum frame, aluminum indicating scale and hand bent glass U-tube. Mounting holes are provided in the frame for mounting to a wall, column or other suitable structure. Well Type Manometer Well manometers are a direct reading device designed for process monitoring, general purpose production testing or laboratory measurement. Designed for a maximum line pressure of 250 PSI (500 PSI optional) these instruments may also be used for tank level, flow measurement and leak detection. Well manometers are constructed of aluminum channel, stainless steel end blocks and stainless steel manometer well. The 7/16" diameter glass tubing is yoke packed with viton gaskets at each end block and is supported at spaced intervals to prevent distortion. In most cases, the uncertainty of a manometer reading is + 1/2 of the smallest scale graduation. This is due to the human eyes ability to interpolate between graduations Inclined Manometer Inclined manometers provide greater readability by stretching a vertical differential along an inclined indicating column, giving more graduations per unit of vertical height. This effectively increases the instruments sensitivity and accuracy. Scales are typically graduated to the hundredth of an inch. The Model 40HEX Inclined manometer is individually calibrated and the angle of inclination is set relative to the instrument level mounted above the channel. The unit is also capable of operating with 350-PSI line pressure. The construction of the 40HEX35 is similar to the well type manometer described above. Additional inclined manometers are available depending on your requirements. Please review the manometer chart on the facing page or contact the factory for assistance.
22
Meriam Manometers
Quick Selection Chart
Manometers: U Tubes & Well Types & Inclines
MODEL
"U" TUBE 10AA25 "U" TUBE Hg FILLED ABSOLUTE 11AA10 HI PRESSURE "U" TUBE 20DAX40 GENERAL PURPOSE 30EBX25 30EBX50 PRECISION VERNIER 30EFX25 Hg FILLED ABSOLUTE 310ECX10 310EFX10 MULTIPLE TUBE 33KBX35 MICRO PRECISION 34FB2TM 34MB2TM ACRYLIC INCLINED 40AM10 40AX10 GENERAL PURPOSE INCLINED 40HEX35 DRAFT GAUGE INCLINED 40GD10
RANGES
(In Inches)
WETTED PARTS
Cast Iron 316 SS PVC Cast Iron 316 SS
PRESSURE RATING
250 PSIG 100 PSIG
MOUNTING STYLES
Wall Table Wall Table
10,20,30,40, 60, 80, 100" 6, 12, 20, 30, 35, 40, 50, 60, 80, 100" 20, 30, 40, 50, 60" 6, 12, 20, 30, 35, 40, 50, 60, 80, 100" 12, 20, 30, 40, 50, 60, 80, 100" 10, 20"
303 SS
400 PSIG
Wall Table Wall, Table Flush Front Pipe Wall, Table Flush Front Pipe Wall, Table Flush Front
303 SS
303 SS
250 PSIG
303 SS
100 PSIG
303 SS
350 PSIG
Stainless Steel
20 PSIG
Acrylic
100 PSIG
Wall Table
Stainless Steel
350 PSIG
Wall
Aluminum
100 PSIG
Wall
Special calibration procedure service is available for those Meriam LFE units, which are governed by quality programs requiring periodic recalibration. The Special Calibration Procedure #A-33544 is designed to meet the basic requirements of MIL-STD-45662A, ANSI Z540, 10CFR50 and MIL-Q-9858A. Contact Meriam direct for information. Meriam LFE Elements are normally rated for maximum flow at 4 or 8 inches of water differential. There is no recovery of pressure differential in a Laminar Flow Element matrix. Filters, inlet and outlet configurations increase the total pressure drop and must be considered when pressure loss considerations are critical.
24
Customer No. :
MERIAM No. :
Tag or ID No. :
GAS: (AIR) (ARGON)
Service Description:
(CARBON DIOXIDE) (HELIUM) (HYDROGEN)
TEMPERATURE AT FLOW:
(Hg @ 0 DEG C) (mm Hg @ 0 DEG C) ( H2O @ 4 DEG C) (mm H2O @ 4 DEG C) (cm H2O @ 4 DEG C) (PSI) (Kg/m2) (Bar) (MILLIBAR) (PASCALS)
SPECIFIC GRAVITY:
VISCOSITY:
(MP)
(CP)
(LB. SEC/FT2)
(LB/(FTS))
25
Model 50MK10
Utilizes stainless steel capillary tubes cemented into a stainless steel body. Inlet, outlet, and differential pressure connections are 1/4" NPT.
Pipe Size
1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 50MK10-8 50MK10-7 50MK10-6 50MK10-5 50MK10-4 50MK10-3 50MK10-2 50MK10-1 .00019 .00062 .00124 .0025 .0046 .0081 .0149 .046 SCFM @ " " " " " " " " " " " " " " 4" water diff. " " " " " " " " " " " " " " " " " " " " "
Model 50MJ10
All stainless steel unit with fused matrix. Differential pressure connections are 1/4" NPT. Line connections 1/2" NPT, except Type 9 which has a 3/4" NPT.
SCFM @ " " " " " " " " " "
8" water diff. " " " " " " " " " " " " " " "
Model 50MW20
All stainless steel welded unit with fused matrix. Line connections are threaded. Differential pressure connections are 1/4" NPT.
SCFM @ 8" water diff. " " " " " " " " " "
Model 50MH10
All stainless steel unit with fused matrix. Line connections are plain ends (no threads) for hose connection. Differential pressure connections are 1/4" NPT.
1" 1 1/4" 1 1/2" 2" 3" 4" 5" 6" 8" 10" 12" 16"
50MH10-1 50MH10-1 1/4 50MH10-1 1/2 50MH10-2 50MH10-3 50MH10-4 50MH10-5 50MH10-6 50MH10-8 X 50MH10-10 X 50MH10-12 X 50MH10-16 X
7.5 16.0 23.0 40.0 90.0 160.0 250.0 360.0 640.0 1000.0 1440.0 2250.0
SCFM @ " " " " " " " " " " " " " " " " " " " " " "
8" water diff. " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " "
Model 50MY15
All stainless steel unit with fused matrix. Differential pressure connections are 1/4" NPT. Line connections are 150 lb. flanges.
50MY15-2 1/2 50MY15-3 50MY15-4 50MY15-5 50MY15-6 50MY15-8 X 50MY15-10 X 50MY15-12 X 50MY15-16 X
SCFM @ " " " " " " " " " " " " " " " "
8" water diff. " " " " " " " " " " " " " " " " " " " " " " " "
Model 50MR2
This unit is for low pressure applications. Differential pressure connections are 1/4" NPT. Aluminim 150 lb. flanges are furnished at inlet and outlet
8" water diff. " " " " " " " " "
Model 50MC2
This unit is for low pressure applications. Differential pressure connections are 1/4" NPT. Designed for use with hose for line connections at inlet and outlet
FOR HOSE 2" I.D. 4" I.D. 6" I.D. 8" I.D.
8" water diff. " " " " " " " " "
26
CC/MIN
5.38 17.5 35.1 70.8 130 229 422 1300
LPM
0.00538 0.0175 0.0351 0.0708 0.130 0.229 0.422 1.30
Kg/M
6.44 x 10-6 2.10 x 10-5 4.21 x 10-5 8.48 x 10-5 1.56 x 10-4 2.75 x 10-4 5.06 x 10-4 0.00156
MAX DP MM H20
101.6 101.6 101.6 101.6 101.6 101.6 101.6 101.6
Accuracy levels available: commercial calibration 0.86% reading: master calibration 0.70% reading: independent lab calibration 0.5% reading. Units available to measure 15,000 SCFM. All units available with filters except those marked with X. For pressures greater than 30 PSIG or 120 F, Meriam Instrument recommends the Universal Calibration Curve Method for calculating flow rate through an LFE. This method incorporates density corrections instead of the ideal gas law corrections common to the Classical LFE equations. While the Classical equations are excellent at conditions below 30 PSIG or 120 F, the Universal Calibration Method provides more accurate results above these values. Consult Meriam for your higher pressure or temperature applications and for sizing assistance.
2.12 4.53 6.51 1.13 2.55 4.53 7.08 1.02 1.81 2.83 4.07 6.37
x x x x x x x x x x x x
10 5 10 5 10 5 10 6 10 6 10 6 10 6 10 7 10 7 10 7 10 7 10.7
212 453 651 1130 2550 4530 7080 10200 18100 28300 40800 63700
0.254 0.543 0.780 1.35 3.05 5.43 8.48 12.2 21.7 33.9 48.8 76.3
203.2 203.2 203.2 203.2 203.2 203.2 203.2 203.2 203.2 203.2 203.2 203.2
NOTES
x x x x x x x x x
10 10 10 10 10 10 10 10 10
6 6 6 6 7 7 7 7 7
1. The flows and differential pressure rating of production units are subject to a variation of plus or minus 10% from the nominal values listed above. 2. Each LFE unit is calibrated with air to Meriam flow standards, which are traceable to the National Institute of Standards and Technology. Meriam calibration flow curves are furnished with each unit. 3. A special service is available for those Meriam LFE units, which are governed by quality programs requiring periodic recalibration. The Special Calibration Procedure A-33544 is designed to meet the basic requirements of 10CFR50, ANSI-Z540-I & ML-Q-9858A. Contact Meriam direct for information. 4. The catalog capacities refer to the following base conditions: Base flowing gas: Air. Base pressure 29.92" mercury absolute. Base temperature: 70F, 530R absolute. Base viscosity: 181.87 microproises. Base Reynolds Number: 300 at 8" H2O, 150 at 4" H2O. 5. SCFM* - See page 6 for definition. 6. All units are offered with optional integral filter on inlet side except those marked (X). Removal or replacement of filter necessities recalibration. 7. Rated flow pressure and temperature for standard units are 30 psig and 150F. to maintain laminar flow, calibration, linearity and accuracy. For higher pressure and temperature rating call Meriam Representative or direct to Meriam Instrument.
x x x x
10 10 10 10
6 7 7 7
x x x x
10 10 10 10
6 7 7 7
INSTALLATION Due to asymmetry of filter elements, calibration accuracy of assembly cannot be guaranteed if filter is removed for any reason. If filter is removed, the assembly should be recalibrated to ensure accurate performance.
27
Principal of Operation
The Accutube is an annular averaging Pitot device, which is simply inserted into a pipe or duct through a weld coupling and packing. Based on pipe or duct size, the Accutube is constructed so that strategically located sensing ports continually sample the impact and static pressures produced by the Accutubes obstruction of the flow stream profile. Within the probe, the impact pressures sensed by the upstream ports are continually averaged in an isolated plenum chamber. Similarly, the static pressures sensed by the downstream ports are averaged in a second isolated plenum. A readout device is then used to indicate the differential between the two-plenum chambers. Meriam Accutubes are provided in a wide variety of models enabling you to select the probe diameter and mounting configuration compatible with your application needs. Meriam also has available special mounting hardware, valves and materials for use in high temperature and pressure applications and corrosive environments. For convenience in selecting and sizing Accutubes for your applications, please refer to the data form found on page 25 in this catalog. Complete the form and submit it to the factory for detailed analysis and configuration. For further assistance on Accutube sizing and selection, feel free to contact Meriam Instrument or your local Meriam representative. You can request the "Accutube Selection and Sizing Data Sheet" if you need detailed steps on selection and sizing.
Accutube: Features
Accuracy
True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs
Convenience
Applicable to gases, liquids, steam Simple installation and maintenance Four standard models and probe sizes: Insertion, Flanged, Wet tap with socket or gear drive retraction, Integral three-valve manifold, optional Bi-directional flow sensing
Confidence
Testing by the Utah Research Laboratory-Utah State University, the University of Michigan and testing against NIST traceable Meriam flow elements confirm typical accuracy of 1% of rate Material Certification and Certificate of Conformance per customer specification are available. Certified welding fabrication to ASME Code, Section IX Procedures. Dye penetrant and hydrostatic testing capability. Canadian registration number.
Efficiency
Low permanent head loss saves energy and cost Multiple tube design offers superior strength and clog resistance Unaffected by wear No system shutdown with wet tap model Ideal for flow system upgrades and expansions Integral 3-Valve head option saves installation piping and transmitter mounting time. Gear Drive wet tap reduces insertion and retraction time
28
Operational savings continue with low-cost maintenance, wet tap flexibility and low permanent head loss.
The Accutube simplifies preventive maintenance with its clog-resistant and wear - free design. This combination brings downtime to a minimum and frees you to concentrate on the process itself. If shutting down your process is too costly, then look to Meriams Wet Tap Accutubes. These Accutubes can be inserted and retracted without process interruption, after being installed without process shutdown. This flexibility gives you the ability to spot check the process, inspect the Accutube and pig or flush the line without Accutube damage while eliminating the need for by-pass piping and valve systems. Choose from socket or gear drive retraction options to meet your needs. Accutubes save you money by causing less permanent pressure loss. Permanent pressure loss (unrecoverable head loss) is the system energy lost due to the primary elements obstruction of the flow stream. This pressure drop is what your pump or fan has to overcome and is directly related to system operating costs. The Meriam Accutube is much less of a flow obstruction than other primary elements. Test results on the Accutube show typical unrecoverable head loss of 2 10 % of the produced differential pressure. This means that there is much less permanent pressure loss, less work for the pump or fan to do and much lower operating costs. The difference in using Accutubes versus orifice plates can add up to hundreds of dollars per year in pump or fan horsepower per measurement point.
Sensor Orientation
HORIZONTAL LINES Bottom Entry Side Entry Top Entry VERTICAL LINES Special 90 Rotated Accutube Head recommended for liquid and steam use.
29
30
03
31
32
33
34
BODY MATERIAL
316SS Head and Probe For Special Material Consult Factory
ORDER
03 SP
SD GD
35
36
37
38
MODEL 952 FS 30 forged steel, slip-on welding, pipe sizes 1"-24" 300lb. raised face For systems where welded connections are required. These flanges are slipped over the pipe which is brought flush with the flange face. The pipe is then welded to the flange.
MODEL 952 FW 30 forged steel, welding neck, pipes 1"-24" 300lb. raised face Similiar to slip-on welding model but for use where weld neck is preferred. These flanges are butted up against the ends of the pipe and welded in place.
MODEL 952 FT 30 forged steel, threaded, pipes 1"-12" 300lb. raised face Designed for systems where threaded connections are suitable and conditions require forged steel.
MODEL 952 PV 15 PVC socket type, pipes 34"-8" 150lb. raised face PVC orifice flanges are socket type where the connecting line is solvent welded to flanges. Pressure connections are corner tap.
39
1. Tap Location Flange Pipe Vena Contracta Corner Radius 2. Plate Material 304 SS 316 SS _________ (other) 3. Base Pressure 14.73 PSIA or _________ (other) 4. Base Temperature 60 F or _________ (other) 5. Inlet Pressure _____PSIG or _________ PSIA or _________ (other units) 6. Flow Temperature _____F or _________ C 7. Pipe Nominal Size _______ inch Schedule _______ or Inside Diameter ________ inch or _________ mm pr _________ (other unit) 8. Vent/Drain Hole & Size (choose one) None____ Vent____ Drain ____ Size _____ Type of Calculation (CHOOSE ONE) Beta Ratio (bore) NOTE: Flow Rate Differential Pressure
Units must be indicated: Flow GPM, PPH, SCFM, etc. DP Inches of Water, PSI, etc. _______units________ _______units________ _______units________ Flow Rate Calculation Desired Flow Units _____ Beta Ratio _____ OR Orifice Bore _____units___ Differential Pressure _____units___
Beta Ratio Calculation Max. Flow Rate Normal Flow Rate Differential Pressure
Differential Pressure Calculation Max. Flow Rate ____Units____ Normal Flow Rate ____Units____ Beta Ratio ____Units____ OR Orifice Bore ____Units____ 9. Type of Fluid (Name) ______ Water ______ Liquid Gas 10. Flow Viscosity _____________________Steam Vapor
IF WATER, STEAM OR AIR S T O P __________ _____________ _____________ centipoise micropoise (other unit) 11. Specific Heat Ratio ___________ 12. Specific Gravity (liquid) OR Density at Base _______ Base _________#/ft or __________gm/cm at Flow _______ Flow _________#/ft or __________gm/cm 13. Specific Gravity (gas/vapor) OR Density at Base ________ Base _________#/ft or ________gm/cm Flow _________#/ft or ________gm/cm 14. CURVE ___Yes ___ No Type of Curve SERIAL NO. ________ Flow vs DP (no additional info needed) Temp Correction Range _____to_______ Press Correction Range _____to_______ Submitted by ______________________________________ Date __________________
40
The LFS-1 Flow Measurement Systems for Meriam Laminar Flow Elements take advantage of the wide flow turndown and the percent of Reading precision of the LFE, as well as the application and calibration expertise of Meriam, to provide a superior gas flow measurement solution. LFEs are industry standards for the calibration of a wide variety of flow devices such as variable area meters, orifice plates, flow nozzles, thermal mass flow meters, turbine meters, regulators and valves. The broad range of flow measurement they offer make LFE Measurement Systems excellent choices for measurements of engine intake air flow, electronics cooling, leak detection and quantification, production line quality control, component design and product certification applications. The integral flow computer makes real time corrections for changes in static pressure, temperature and relative humidity to provide the most accurate results possible. Calibration coefficients for up to five (5) LFEs can be stored in memory and called up for use later with a push of a button. Special application requirements can often be accommodated by the LFS. For example, simultaneous flow measurement of two LFEs can be made and the summation of the two flows calculated and displayed. Or, for testing over a wide range for flow, the LFS can be set up to automatically switch from one LFE to another as flow rates change. Standard digital outputs on the LFS change state as the flow rate moves from the capability of one LFE to another. External solenoid valves can be used to switch the DP and P transducers to the active LFE. For control or data transmission purposes, the LFS Flow Measurement System has both analog and digital outputs. 4 20 mA and 0 10 volts analog output options are ideal for control and recording functions. RS-232 or RS-485 digital communications are standard to facilitate communication with a PC and documentation of test results. The LFS Flow Measurement Systems (LFS) provide standard system accuracys of 1.0% of Reading over a 10:1 flow turndown and 1.1% over 20:1 turndown. Calibration of the LFE and LFS Flow Measurement System together makes this possible. By using better calibration standards, Meriam can offer LFS accuracy as low as 0.60% of Reading over a 10:1 flow turndown. All LFS packages include complete system calibration and NIST traceable documentation. LFEs and systems cover gas flow ranges from 0.5 SCCM to 15,000 SCFM. See the Laminar Flow Element section of this catalog for more details on the LFE models available.
41
42
SMVs reduce the total installed cost of gas or vapor flow meters by: 1) reducing the number of secondary instruments needed for gas or vapor flow from four to two 2) directly mounting to primary elements designed for flange mounting, eliminating high and low pressure piping 3) eliminating the need for mounting brackets 4) eliminating or reducing to a minimum the wiring between transducers and the flow computer (temperature wiring still needed) 5) integrating the flow computer within the SMV
To take full advantage of the strengths that SMVs offer, Meriam Instrument has two head - type primary elements to choose from. Traditional orifice plates and flanges are described earlier in this catalog and SMV programming includes all common orifice plate calculation models. Accutubes are also prime candidates for SMVs. Meriam has designed a new style of Accutube averaging pitot tube that will be of great interest to customers needing accurate and convenient flow measurement of steam, gas or liquid flow through a process pipe. Models 40H, 41H, 42H, 43H, 70H and 72H are presented earlier in this catalog. These Accutubes have integral 3-valve manifold heads that allow DP or Multivariable transmitters to be bolted directly to the Accutube head. This feature eliminates mounting brackets, connecting tubing and tube fittings. O-rings provide the seal to the transmitter and temperatures and pressures in excess of most transmitter limits are supported. Models 40H (single support) and 41H (double support) are for DP transmitters and have 316LSS probes and 3-valve instrument heads. Models 42H (single) and 43H (double) are for the SMV transmitter since they include an integral 100-ohm RTD temperature device. The RTD is serviceable without shutting off the flow stream and without removing the transmitter from the Accutube. For wet - tap style Accutube applications, Meriam offers the 70H model for DP transmitters and the 72H model for SMV transmitters. In combination, the new Accutubes and SMV transmitters represent a convenient and cost effective way to add measurement points to existing process areas or to equip a new plant or expansion. Meriam Instrument offers complete technical assistance and product lines for all of your pressure and flow measurement needs. Please call Meriam or your local Meriam Representative for application assistance, price quotes and delivery information today.
43
10920 Madison Avenue Cleveland, OH 44102 Telephone 216-281-1100 Fax: 216-281-0228 www.meriam.com E-mail: meriam@meriam.com