Sie sind auf Seite 1von 1

24th Symposium on Fusion Technology

11 - 15 September 2006 - Palace of Culture and Science, Warsaw, Poland

TOPIC: H - Fuel Cycle and Breeding Blankets

VALIDATION OF THE ITER CRYOSORPTION PUMPING CONCEPT UNDER TRITIUM (P4-H-173)


Christian Day(1), Damian Brennan(2), Patrick Camp(2), Hans S Jensen(1)
1. Forschungszentrum Karlsruhe, Institute of Technical Physics (ITP) Hermann-von-Helmholtz-Platz 1 76344 Eggenstein-Leopoldshafen Germany 2. EURATOM/UKAEA Fusion Association Culham Science Centre OX143DB Abingdon UK

Forschungszentrum Karlsruhe (FZK) is developing the ITER prototype torus exhaust pumping system comprising 8 identical cryopumps to provide a high pumping speed and capacity, as well as the 2 cryostat cryopumps and the 3 cryopump systems for the ITER Neutral Beam Injectors. To pump helium and protium, which cannot be condensed at the available 5 K cooling conditions, the cryopanels are coated with activated charcoal granules. As this holds for all the vacuum systems mentioned above, which incorporate a similar modular cryopanel design, extensive testing was initiated to ensure compatibility to all design requirements. Therefore, a task was launched within the Task Force Fusion Technology at JET to build and install a large scale tritium test arrangement, to assess in detail the charcoal-tritium interaction and to derive performance parameters essential to the design of the ITER cryosorption pumps. For this purpose, a prototype cryosorption pump (PCP) comprising three ITER-relevant cryopanels was designed and manufactured at FZK. Upon installation in one of the cryovacuum modules of the AGHS (Active Gas Handling System), the PCP was at first used to pump tritiated gas from the torus and neutral beam injectors [1]. In a second experimental stage, the PCP was undergoing a parametric programme in several campaigns with pre-defined gases fed from an external supply. This paper summarizes the conclusions drawn from the parametric programme and features some of the highlight results. It presents measurements for competitive effects in concurrent pumping of gases pumped by sorption (helium) and gases pumped by condensation (tritium), as it is typically the case for the ITER exhaust gas. The experiments at AGHS also included the investigation of any parasitic effects of pre-sorbed hydrocarbons (methane, ethane, propane) on the nominal pumping performance of the cryopanels for tritium-helium mixtures. Representative results will be presented. Based on the performance data measured in the PCP tests at JET, it could be confirmed that the cryosorption pumping concept (which has been investigated in full detail in a parallel experiment for non-tritiated gases), is a sound and reliable solution for ITER. No show-stoppers have been identified. [1] Chr. Day et al., Fusion Science and Technology 48 (2005) 29-34

292

Das könnte Ihnen auch gefallen