References, characteristics

System Type of transmission Nominal sensing distance (Sn) (1) With 50 x 50 mm reflector (2) With 24 x 21 mm reflector

Thru-beam 1 Infra-red 10 m

Reflex 2 Infra-red 3 m (1) 2 m (2)

Polarised reflex 3 Red 2 m (1) 1 m (2)

Diffuse 2 Red 0.10 m Infra-red 0.40 m

References
3-wire, PNP Light or dark programmable switching Light or dark programmable switching XUB-H103534 XUB-H03353 XUB-H023539 XUB-H103535 XUB-H403535

3-wire, NPN

XUB-J103534

XUB-J03353

XUB-J023539

XUB-J103535

XUB-J403535

Transmitter Weight (kg)

XUB-H10301 0.075

0.075

0.075

0.075

0.075

Characteristics
Ambient air temperature Vibration resistance Shock resistance Degree of protection Connection Materials Rated supply voltage Voltage limits Switching capacity (sealed) Voltage drop, closed state Current consumption, no-load Maximum switching frequency Delays Function table Operation : - 25+ 55 C. Storage : - 40+ 70 C 7 gn, amplitude 1.5 mm (f = 1055 Hz), conforming to IEC 68-2-6 50 gn, duration 11 ms, conforming to IEC 68-2-27 IP 67 conforming to IEC 529 Pre-cabled, diameter 4 mm, length 2 m, wire c.s.a. : 4 x 0.22 mm2 (3 x 0.22 mm2 for XUB-H10301) Case : PC/ABS ; lens : PMMA ; cable : PVC a 1224 V with protection against reverse polarity a 1030 V (including ripple) 100 mA with overload and short-circuit protection 1.5 V Transmitter : 20 mA ; receiver : 30 mA ; reflex and diffuse : 35 mA 500 Hz (thru-beam system : 400 Hz) First-up : 30 ms ; response : 1 ms ; recovery : 1 ms (thru-beam system : 1.5 ms) Function Thru-beam and reflex systems No object present Object present in the beam in the beam Diffuse system No object present in the beam Object present in the beam

Output state (PNP or NPN) indicator (LED, illuminated when detector output is ON)

Light switching Dark switching

30111/2

Te

Photo-electric detectors
Miniature cylindrical M18 x 1 threaded, type XUB (short) d.c. supply. Solid state output Pre-cabled
Compatibility : pages 30190/2 and 30190/3 Accessories : pages 30180/2 and 30180/3 Detection curves Thru-beam system
of beam cm 6 4 12 mm T 2
-2 -4 -6 Sn 10 m 10

Curves, dimensions, schemes


Reflex system
of beam cm 6 4 T/R 2
m -2 -4 -6 0,2 2 3 m

Diffuse system (Sn = 10 cm)


of beam cm 1 2 0,5 -0,5 -1

Diffuse system (Sn = 40 cm)


of beam cm 1 0,5 -0,5 -1 Sn 0,40 m

T/R

1
10 cm

T/R

1
40 cm

Sn 2 m

(1)

Sn

0,10 m

Sn 3 m (2)

With reflector XUZ-C50 (1) Polarised reflex XUB-i023539 (2) Reflex XUB-i03353 Excess gain curves (ambient temperature : + 25 C) Thru-beam system Reflex system
gain 500 300 gain
50 30 20 15 10 7 5 3 2 1

Object 10 x 10 cm 1 White 90% 2 Grey 18% Diffuse system (Sn = 10 cm)


gain 50 30 20 15 10 7 5 3 2

Object 20 x 20 cm 1 White 90% 2 Grey 18% Diffuse system (Sn = 40 cm)


gain 50 30 20 15 10 7 5 3 2 1

2 1

100 50

10 5 3 1 0,1 0,2 0,5 1 0,8 0,3 2 3 6 5 10 D (m)

0,1 0,25 0,5 1 0,7

2 345

10 D (m)

1 0,1 0,2 0,5 1 2 5 10 15 20 60 D (cm)

0,1 0,2

0,5 1

10

15

20 40 60 D (cm)

With reflector XUZ-C50 1 Polarised reflex XUB-i023539 2 Reflex XUB-i03353 Dimensions XUB-H, XUB-J 4 M18x1 (2) (1)

Object 10 x 10 cm White 90% XUB-H, XUB-J + XUB-Z0i (3) M18x1 (2)

Object 20 x 20 cm White 90%

(1)

12

R T

R E 50 80 (3) XUB-Z0i : 90 mirror adaptor, see page 30180/3 Note : Fixing nut tightening torque : < 4 N.m 24

4 34 55 (1) LED (2) Adjustment potentiometer Wiring schemes (3-wire a) Transmitter


BN BU VI

24

Light switching (no object present) Thru-beam receiver & reflex Diffuse PNP output PNP output
OG OG

Dark switching (no object present) Thru-beam receiver & reflex Diffuse PNP output PNP output
BN BK BU

Test

BN BK BU

BN BK BU OG

24

BN BK BU OG

NPN output
OG BN BK BU

NPN output
OG

NPN output
BN BK BU

NPN output
BN BK BU OG

BN BK BU OG

Cable connections Solid state output - () BU (Blue) - (+) BN (Brown) - (OUT) BK (Black) - (Prog.) OG (Orange) - (Test) VI (Violet) for XUB- H10301 only

Verification of correct operation Thru-beam and reflex systems


Signal level Red LED
1,5 1 0,7

LED off LED on

Optimum alignment

Te

30111/3

Photo-electric detectors
Miniature cylindrical M18 x 1 threaded, type XUB (short) d.c. supply. Solid state output Connector
Compatibility : pages 30190/2 and 30190/3 Accessories : pages 30180/2 and 30180/3

References, characteristics

System Type of transmission Nominal sensing distance (Sn) (1) With 50 x 50 mm reflector (2) With 24 x 21 mm reflector

Thru-beam 1 Infra-red 10 m

Reflex 2 Infra-red 3 m (1) 2 m (2)

Polarised reflex 3 Red 2 m (1) 1 m (2)

Diffuse 2 Red 0.10 m Infra-red 0.40 m

References
3-wire, PNP Light or dark programmable switching Light or dark programmable switching XUB-H103534D XUB-H03353D XUB-H023539D XUB-H103535D XUB-H403535D

3-wire, NPN

XUB-J103534D

XUB-J03353D

XUB-J023539D

XUB-J103535D

XUB-J403535D

Transmitter Weight (kg)

XUB-H10301D 0.020

0.020

0.020

0.020

0.020

Characteristics
Ambient air temperature Vibration resistance Shock resistance Degree of protection Connection Materials Rated supply voltage Voltage limits Switching capacity (sealed) Voltage drop, closed state Current consumption, no-load Maximum switching frequency Delays Function table Operation : - 25+ 55 C. Storage : - 40+ 70 C 7 gn, amplitude 1.5 mm (f = 1055 Hz), conforming to IEC 68-2-6 50 gn, duration 11 ms, conforming to IEC 68-2-27 IP 65 conforming to IEC 529 Connector (suitable female connectors and extension cables types 3, 4, 5, see pages 307/2 and 307/3) Case : PC/ABS ; lens : PMMA a 1224 V with protection against reverse polarity a 1030 V (including ripple) 100 mA with overload and short-circuit protection 1.5 V Transmitter : 20 mA ; receiver : 30 mA ; reflex and diffuse : 35 mA 500 Hz (thru-beam system : 400 Hz) First-up : 30 ms ; response : 1 ms ; recovery : 1 ms (thru-beam system : 1.5 ms) Function Thru-beam and reflex systems No object present Object present in the beam in the beam Diffuse system No object present in the beam Object present in the beam

Output state (PNP or NPN) indicator (LED, illuminated when detector output is ON)

Light switching Dark switching

30111/4

Te

Photo-electric detectors
Miniature cylindrical M18 x 1 threaded, type XUB (short) d.c. supply. Solid state output Connector
Compatibility : pages 30190/2 and 30190/3 Accessories : pages 30180/2 and 30180/3 Detection curves Thru-beam system
of beam cm 6 4 12 mm T 2
-2 -4 -6 Sn 10 m 10

Curves, dimensions, schemes


Reflex system
of beam cm 6 4 2 T/R
m -2 -4 -6 0,2 2 3 m

Diffuse system (Sn = 10 cm)


of beam cm 1 2 0,5 -0,5 -1

Diffuse system (Sn = 40 cm)


of beam cm 1 0,5 -0,5 -1 Sn 0,40 m

T/R

1
10 cm

T/R

1
40 cm

Sn 2 m

(1)

Sn

0,10 m

Sn 3 m (2)

With reflector XUZ-C50 (1) Polarised reflex XUB-i023539D (2) Reflex XUB-i03353D Excess gain curves (ambient temperature : + 25 C) Thru-beam system Reflex system
gain gain
50 30 20 15 10 7 5 3 2 1

Object 10 x 10 cm 1 White 90% 2 Grey 18% Diffuse system (Sn = 10 cm)


gain

Object 20 x 20 cm 1 White 90% 2 Grey 18% Diffuse system (Sn = 40 cm)


gain

500 300 100 50

2 1

50 30 20 15 10 7 5 3 2

50 30 20 15 10 7 5 3 2 1

10 5 3 1 0,1 0,2 0,5 1 0,8 0,3 2 3 6 5 10 D (m)

0,1 0,25 0,5 1 0,7

2 345

10 D (m)

1 0,1 0,2 0,5 1 2 5 10 15 20 60 D (cm)

0,1 0,2

0,5 1

10

15

20 40 60 D (cm)

With reflector XUZ-C50 1 Polarised reflex XUB-i023539D 2 Reflex XUB-i03353D Dimensions XUB-H, XUB-J 4
(2)

Object 10 x 10 cm White 90% XUB-H, XUB-J + XUB-Z0i (3)

Object 20 x 20 cm White 90%

(1)

M18x1

(2)

(1)

12

R T

34 55 68

M18x1

24

50 95

24

(1) LED (2) Adjustment potentiometer Wiring schemes (3-wire a) Transmitter


1 3 2 Test

(3) XUB-Z0i : 90 mirror adaptor, see page 30180/3 Note : Fixing nut tightening torque : < 4 N.m Light switching (no object present) Thru-beam receiver & reflex Diffuse PNP output PNP output
2 1 4 3

2 1 4 3

Dark switching (no object present) Thru-beam receiver & reflex Diffuse PNP output PNP output

1 4 3 2

24

1 4 3 2

NPN output
2 1 4 3

NPN output

NPN output
2 1 4 3

NPN output
1 4 3 2

1 4 3 2

Connector schemes (solid state). Detector connector pin view Transmitter Thru-beam receiver, reflex and diffuse
1 ( +) 2 Test 3 () 4 2
Programming

Verification of correct operation Thru-beam and reflex systems


1,5 Signal 1 level 0,7

1 (+) 4
Output

LED off Red LED LED on

3 ()

Optimum alignment

+
30111/5