Sie sind auf Seite 1von 1

Siemens AG 2012

SIMOTICS SD 1LG Standard Motors


Motors with High Efficiency IE2
Self-ventilated motors
Cast-iron series 1LG6

Selection and ordering data (continued)


Operating values at rated output
Prated, Prated, Frame nrated, Trated, IE
rated, rated, rated, cos Irated, TLR/ ILR/ TB/ LpfA, LWA,
50 Hz 60 Hz size
50 Hz
50 Hz class 50 Hz, 50 Hz, 50 Hz, rated, 50 Hz, Trated Irated Trated 50 Hz 50 Hz
1)

4/4

3/4

2/4

50 Hz,
4/4

Cast-iron series
1LG6 IE2 version in accordance with
IEC 60034-30
Order No.
dB(A) dB(A) New *

400 V

mIM B3 J

Torque
class

kW
kW
FS
rpm
Nm
%
%
%
A
kg
kgm2
CL
Cooling: Self-ventilated (IC 411)
Efficiency: High Efficiency IE2, service factor (SF) 1.15
Insulation: Thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
4-pole: 1500 rpm at 50 Hz, 1800 rpm at 60 Hz 1)
18.5 21.3 180 M 1470 120 IE2 91.2 91.5 91.0 0.83 35.52) 2.5 6.8 3.0 60
73
1LG6183-4MA 160
0.12
16
22
25.3 180 L 1465 143 IE2 91.6 92.5 92.5 0.84 41.52) 2.5 7.5 3.3 64
77
1LG6186-4MA 185
0.14
16
30
34.5 200 L 1475 195 IE2 92.3 92.8 92.1 0.85 552) 2.4 6.7 3.1 63
76
1LG6207-4MA 225
0.23
16
37
42.5 225 S 1470 240 IE2 92.7 93.6 93.7 0.87 662) 2.6 6.5 3.0 61
74
1LG6220-4MA 285
0.40
16
45
52
225 M 1475 291 IE2 93.1 93.6 93.5 0.87 802) 2.6 7.0 3.1 62
75
1LG6223-4MA 315
0.53
16
55
63
250 M 1480 355 IE2 93.5 93.7 93.4 0.85 100
2.8 7.1 3.0 62
75
1LG6253-4MA 390
0.56
16
75
86
280 S 1485 482 IE2 94.0 94.3 94.0 0.87 1322) 2.5 7.0 2.9 67
80
1LG6280-4MA 560
1.3
16
90
104
280 M 1486 578 IE2 94.2 94.4 94.0 0.87 1592) 2.6 7.3 3.1 67
80
1LG6283-4MA 640
1.4
16
110
127
315 S 1490 705 IE2 94.5 94.6 94.0 0.86 1952) 2.7 7.4 3.0 68
81
1LG6310-4MA 750
2.0
16
132
152
315 M 1488 847 IE2 94.7 94.9 94.6 0.87 2302) 2.7 7.1 2.9 67
80
1LG6313-4MA 870
2.3
16
160
184
315 L 1488 1027 IE2 94.9 95.2 94.8 0.87 2803) 3.2 7.5 3.0 70
83
1LG6316-4MA 950
2.8
16
200
230
315 L 1490 1282 IE2 95.1 95.3 94.9 0.87 3503) 3.2 7.9 3.1 70
83
1LG6317-4MA 1120 3.4
16
250
288
315 L 1488 1605 IE2 95.1 95.2 94.7 0.87 435
3.1 7.7 3.2 73
87
1LG6318-4MA 1270 4.2
16
315
362
315 L 1488 2022 IE2 95.1 94.9 94.4 0.86 560
3.4 7.9 3.2 74
89
1LG6312-4MA 1480 5.0
16
Voltages
50 Hz
50 Hz
50 Hz

230 V/400 VY
400 V/690 VY
500 VY

50 Hz

500 V
1)

Further voltages
Types of construction
Without flange

With flange

60 Hz 1) 460 VY
60 Hz 1) 460 V

No. of
poles
4
4
4

Motor type

Version

1LG6183 ... 310, 1LG6313


1LG6183 ... 318
1LG6183 ... 310, 1LG6313

Standard
Standard
Without additional
charge
4
1LG6183 ... 318
Without additional
charge
For additional charges, code numbers and descriptions, see from Page 2/78
No. of
Motor type
Version
poles
IM B3/6/7/8 4)
4
1LG6183 ... 318
Standard
IM V6 4)
4
1LG6183 ... 310, 1LG6313
Standard
4
1LG6316, 1LG6317
Without additional
charge
4
1LG6312, 1LG6318
On request
IM V5 without protective cover 4) 4
1LG6183 ... 310, 1LG6313
Standard
4
1LG6316, 1LG6317
Without additional
charge
4
1LG6312, 1LG6318
On request
IM B5 5)
4
1LG6183 ... 318
With additional charge
IM V1 without protective cover 4
1LG6183 ... 310, 1LG6313
With additional charge

Order code(s)
1
6
3

...
Order code(s)
0
0
9

M1E

9
0
9

M1E

M1D

9
1
1

M1D

8
9
4

M1G

5) 6)

IM V3 5)
IM V1 with protective cover

4
4
4

1LG6312, 1LG6316 ... 318


1LG6183 ... 310, 1LG6313
1LG6183 ... 318

With additional charge


With additional charge
With additional charge

5) 6) 7)

IM B35
4
1LG6183 ... 318
With additional charge 6
Further types of construction For additional charges, code numbers and descriptions, see from Page 2/83
9
Special versions
Options
For additional charges, code numbers and descriptions, see from Page 2/94
1LG6 . . . - . M . -Z

1)

Operating values at rated output for 60 Hz are available on request.

2)

For connection to 230 V, parallel feeders are necessary.

3)

For connection to 400 V, parallel feeders are necessary.

4)

If 1LG6 motors in types of construction with feet IM B6, IM B7, IM V6 or


IM V5 without protective cover are fixed to the wall, it is recommended that
the motor feet are supported.

5)

1LG6220 to 1LG6318 motors are supplied with two screw-in eyebolts conforming to IM B5, whereby one can be repositioned to conform to IM V1 or
IM V3. It is important to note that stress must not be applied perpendicular
to the ring plane.

6)

2-pole motors 1LG6316-... to 1LG6317-... and 1LG6312-... (motor series


1LG6 frame size 315 L) in 60 Hz version available on request.

7)

The "Second shaft extension" option, order code K16 is not possible.

...
Order code(s)
. . .+. . .+. . .+. . .

Order identically priced predecessor type for 1LG6...2AA../


1LG6...2AB.. 2-pole motors or 1LG6...4AA.. 4-pole motors using the options
for country certificates (D31, D33, D34, D35, D40), marine certificates
(E11, E21, E31, E51), explosion-proof version (M72, M73, M34, M35, M38,
M39, M74, M75, C27) and IE3 version for SH 315 (D25).
For 1LG6312-2MA.., 1LG6312-4MA.., 1LG6318-2MB.. and 1LG6318-4MA..
motors that do not have predecessor types, it is not possible to use the
options for country certificates (D31, D33, D34, D35, D40), marine certificates (E11, E21, E31, E51), explosion-proof version (M72, M73, M34, M35,
M38, M39, M74, M75, C27), brakes, brakes with encoder (G26, H47, H62,
H63, H64, H98, H99), low-noise versions (K37, K38) and mounting of a
separately driven fan, separately driven fan with encoder (G17, H61, H64,
H97, H99).

Siemens D 81.1 January 2012