New convenient functions are avallable, such as check for inappropriate calibration results by flag indication compared to the previous results, and
capability of using multiple bottles of the same reagent item on the same tray, etc.
L '::r: '
.tr
i:
:1ii:11::titi:il;
Improvements to the optical measurement system have reduced reaction volume by maximum 407o compared to the former model.
Analy zer can test small volume samples (around 50 lrl.), such as those obtained from the elderly and infants effectively.
r_) :: r:'i::++ : rlill
Automatic reagent residual volume calculation system allows display of realtime residual volume percent.
'r
,--".,i'-j
:F
1: .. li'.1r:' r?"-:f-i
*\\\\\\\
t i t
Reagent probe
ffimp:annaat*:
't
! I
si
Sample tray
LJp
t*
4t)
p:mtnmr":t silfrrlp:$*s
r:n hmmr#.
t!,JL:q+
mpti*r:
ffi Separate probes are used for 1st and 2nd reagents to avoid carryover.
mCI)
can be
Auto-gain function when lamp is replaced. Reaction waste is stored in a dedicated tank.
w Test result data are compatible with BiOLiS 24i. w Sampling-stop function using END barcode
available.
is
ffi Reaction cuvette washing with heated water and 2 kinds of washing solution (alkaline and acidic) and
heated water washing for all probes.
Biolis
24,).
Specially developed to utilize air pressure mixing system. The material is water repellent plastic (Semidisposable)
RE
UCTION
1I
*ntfn
.;,.ir-1
[#
UC*U
AIR
SAMPLE
REAGENT
. . .
No carry-over because a stirrer is not used No water consumption for stirrer washing No dilution of the reaction solution by washing water from the stirrer
o Reaction tray contains 60 reaction cuvettes. o Reaction cuvettes are washed by heated water and 2 kands of washing solution (alkaline and acidic) for each test.
Cuvette washing system Air pressure mixing system Reaction cuvettes (60 pieces) Reagent probe washing station Sample probe washing station
ffi
Operation
is
started
by a single click
Atrr:ri:enr:+
U
t-aj)l]
tlifi:tr :!n0
D:-tr{iilrrl 0,i.,+:r0
l-i
5.-:!tr
Analysis
Analysis method Number of test items on board Throughput Analysis method Calibration curve Sample kind Sample container Number of samples on board Number of sample trays Sample dispense volume Dilution ratio
STAT sample
or
24+3 (lSE)
240 tests/hour, 400 tests/hour including ISE End point assay, rate assay, ISE (option)
Sample
6, 10- 100
Tested by interruption
Sample barcode Number of bottles on board Bottle volume Reagent dispense volume
Supplied as an option
72 (36 items)
or 48 (24 items)
13,25,40 mA or 20,40,60 ml
20- 240 p,A (1
pl
step)
%o
Reagent
Reagent storage Residual volume Reagent tray Reagent barcode Cuvette material Reaction volume Reaction time Reaction temperature
or 24-sectors (Removable)
i
Supplied as an option
Plastics (Sem -d isposable)
Minimum 120
trt"A,
maximum 250
p,0
opt cal measurement Reaction system opt cal source opt cal range
Cuvette washing Reaction waste collection
Pure water consumption Run monitor
oD 0- 2.5
On-line washing with heated water and 2 kinds of washing solution
Voice message
Optical absorbance graphic display Based on Westgard's algorithm, etc. Announce test status
10,000 samples maximum lnternal, External (option) AC 100/115/230 volt (50/60 Hz)
Ambient temperature '15- 30"C, Humidity 30- 80% (No condensation)
User interface
(h)
Option
Report system Sample barcode, Reagent barcode Water purification system External printer XSpecification may change without notice due to modification
LD (LDH)
ChE
Y.GTP
CRE
CK (CPK)
LAP
TG
HDL_C
Fe
Clinical chemistry
ALD
BUN
UA
Ca
T-CHO
IP
TP D.BIL
ALB T.BIL
GA APO CIII
GLU
NEFA
sALB
HBAO
lmmuno-assay
2-m
lg-E
Tf
TDM
HAL
D dimer
PB
Coagulation
ISE
PLG
K
Control PCB Reagent pump Reagent probe inside washing pump Sample pump Sample probe inside washing pump
t,
controller
. ISE module is equipped with BiOLiS 24i Premium. . lt makes easy to replace the electrode.
Consumables of the ISE module as follows . Calibrator . Cleaning solution . Electrode (Na, K, Cl, Ref)
Standard color
(Emerald Green)
Optional color
(Orange)
Patient report
PATIENT REPORT
P,{T Ef'tT HtF llRT
RUN
DATE ZDO?./03/
I6
SAIvIPLE No.
COMMENT
PREFERENCE REMARKS
DOCTOR
SECTION
RESULT
COMMENT
ALB
f TEST
/
2OO?/03/
sil
380-520
12.0-18.0 14.0-40.0
16
UNIT
PREFERENCE
3,9
440 H ,::i :
LP
LDH GOT
174
96 L
36
iti..'i
TPT
39 H
103
;r.;,. I
T-CH
TG
104-338
T'BIL
This system can handle data from various kinds of analyzer, other than BiOLiS 24a Premium (for example, blood cell counter and blood gas analyzer) collected through an on-line transfer system, and the results
can be incorporated into a single report.
ilOC graph
lF-ql
: I
Pnnt
lF-!l
lF-rl
tF
fl
tF-r2l
10
,i
.-i
i i,I ,'--.
.''
,t.- -, . :'
,,