Beruflich Dokumente
Kultur Dokumente
SUBJECT:
SUBJECT:
BULLETIN INDEX
08/09/04
BULLETIN #
RECOMMENDED ACTION FOR FIELD MACHINES AT SETUP NEXT PM NEXT SERVICE CALL INFORMATION ONLY
KM-C2230-01
Updated Serial Number
KM-C2230
08/09/04
From introduction
Subject
Available Options are a DP-621 (Document Processor), DF-626 (Saddle Stitch Finisher), PH-620 (Punch Unit for Saddle Stitcher), DF-621 (Staple Finisher), JS-621 (Third Tray for DF-621), DU-621 (Duplex Unit), PF-621/625/627 (Paper Feed Cassettes), etc. (See Page 4 for a full list of accessories.)
GENERAL INFORMATION
Product Name Product Code Product Training Diagnostic Center Contact Number Software Solution Group Email KMAconnect Web Site KMAconnect Help Desk Kyocera Mita Web Site Kyocera Technical Support (Email) Material Safety Data Sheet Requests National Processing Center (Customer Service) KM-C2230 5HNxxxx Learning Center on KMAconnect 1-800-255-6482 software_solution@kyoceramita.com kmaconnect.com dealersupport@kyoceramita.com kyoceramita.com support@kyoceramita.com. support@kyoceramita.com. 1-866-596-2372 or customer_service@kyoceramita.com
225 Sand Road P.O. Box 40008 Fairfield, New Jersey 07004-0008, USA
PRODUCT TRAINING
*Product Training Prerequisites Learning Center on KMAconnect (Technical Training) KM-C2030/3130
Online Technical Training is available for the KM-C2230 for Technicians who have successfully completed training on the KM-C2030/3130. Log-on to KMAconnect, browse to the Learning Center and locate the course. Technicians will automatically be certified after they complete the online course and pass the Test. A Certificate of Completion will be forwarded within a few days after achieving the passing grade. Each Technician who takes the on-line course must have their own Log-in Name and Password, so that the Certificates and the Dealer training records are processed correctly. Technical Training on the KM-C2230 for technician (s) who do not meet the prerequisites will be available at the National Training Center in Dallas. Enroll on-line through KMAconnect (Learning Center/Technical Training/Courseware/Classroom Scheduling) or contact your Regional Office. For your convenience, a KM-C2230 CD-ROM Training Kit is also available using P/N 8995HN60, price $ 88.32. However, we recommend using the Learning Center on KMAconnect, which is available at no charge.
SERVICE DOCUMENTATION
Description KM-C2230 Service Manual KM-C2230 Parts List DF-626/PH-620 Service Manual DF-621/JS-621 Parts List KM-C2230 Operation Guide Part Number 5HN70760 5HN70770 5HR70760 5HR70770 Available on KMAconnect Price $30.00 $15.00 $30.00 $20.00 N/C
The DF-626/PH-620 Service Manual contains the DF-621/JS-621, PF-625/627, PF-621, DP-621 and DU-621 Service Manuals. The DF-621/JS-621 Parts List contains the DF-626, PF-621, PF-625, PF-627, DP-621 and DU-621 Parts Lists.
ACCESSORY / OPTIONS
ITEM Part Number Description DP-621 025HP200 Reverse Automatic Document Feeder DF-626 025HR200 Saddle Stitch Finisher PH-620 00108141 Punch Unit Kit for DF-626 DF-621 025HS200 Staple Finisher JS-621 025HS201 Third Tray for DF-621 DU-621 025HT200 Duplex Unit PF-625 025HV200 Paper Feed Cabinet (500 Sheet x 1 Drawer + Storage) PF-627 025HW200 Paper Feed Cabinet (500 Sheet x 2 Drawers) PF-621 025HX200 Large Capacity Cabinet (2,500 Sheet x 1 Drawer) CB-621 80080800 Copy Desk Platen Cover Type E 025NH200 Platen Cover Fiery X3e 22C-KM 055HY200 Embedded Controller Interface Kit 055HY201 Interface Kit for Fiery X3e 22C-KM HD-21 055HN200 40GB Hard Disk Drive Kit IB-80 055HN201 Parallel Interface Kit for Standard Controller SD-168-256 82142256 256MB Copier Memory Kit, Memory Upgrade, 8405G000 128MB Memory Upgrade for Fiery Controller X3e X3e 128MB Mechanical Counter 82140126 Mechanical Counter Attachment Kit for Key 00108145 Socket Assy Counter Key Counter B 82142540 Key Counter only Staple Cartridge 5AX82010 Staple Cartridge for DF-621 (3,000 pcs x 3 cart/case) Staple Cartridge 5GH82010 Staple Cartridge for DF-626 (5,000 pcs x 3 cart/case) As a Customer Service, KMA is stocking and selling Memory. You can order from KMA by using the Part Numbers shown above. Optional DIMMs can also be purchased from TechWorks @ www.techworks.com. The X3e 128MB Memory Upgrade Kit is Exclusive Memory for the Fiery and contains Special DIMMs. This is the Only Memory Upgrade that should be used. Other Memory will not be recognized and will void the Warranty.
Docbuilder Pro Dongle Ver 1.5 Hot Folders Spot On Auto Trap Fiery System Software
Please refer to Page 13 for instructions to activate a Graphic Arts Feature for the Fiery X3e.
MEMORY REFERENCE
Memory Type Standard PCL Controller Printer Memory Optional Fiery X3e+ Controller Standard 256MB DIMM Maximum 256MB + 256MB DIMM = 512MB + 40GB HD (Opt)
128MB DIMM
The Standard PCL Controller Memory is shared with the Copier. The PCL Controller is built-in to the Copier Main Board. This Memory should not be removed if the Optional Fiery X3e is installed.
KM-C2230 Firmware
Firmware Name Firmware Version MSC (MFP Control Board) 4036-10G0-18-00 APP (MFP Control Board) 4036-10G0-18-00 Font (MFP Control Board) 4036-10G0-18-00 LPH (LED Drive Board) 4036-53G0-03-00 IR (Image Processing Board) 4036-23G0-02-00 PRT (Control Board) 4036-50G0-22-00 Current Firmware for the KM-C2230 will be posted on KMAconnect. Refer to Page 2-32 in the Service Manual for the Procedure on Upgrading Firmware using the Compact Flash Method. Note: Compact Flash Cards cannot be formatted on a Windows Operating System. Buffalo Technology Compact Flash Cards can be purchased from TechWorks @ www.techworks.com.
* Repair PCB Price includes credit issued after return of old Board.
Defective replacement PCBs being returned within the 120 Day warranty period must be returned to the National Return Center utilizing the Online Return Authorization Request Form on KMAconnect. A copy of this form must be filled-out completely and returned with the Circuit Board for Credit. Any associated mounting brackets, hardware, system software and original packaging must be included with the claim. Credit will then be issued to your account. Defective PCBs out of warranty may be returned for repair to the National Return Center using the Online Repair Board Core Form.
All Part Numbers and Pricing Subject to Change without Notice.
Exposure System Developing System Charging System Image Transfer System Paper Separating System Fusing System Types of Original Max. Original Size Multiple Copies Warming-up Time Image Loss First Copy Time
Fixed Zoom Ratios Reduction Enlargement Variable Zoom Exposure Lamp Power Requirements Frequency Max Power Consumption Dimensions Space Requirements Weight Grounding Termination
Note: A dedicated AC line with an isolated ground is strongly recommended. A dedicated line mandates the exclusive use of an electrical branch circuit where the receptacle grounding terminal is grounded by an insulated grounding conductor that is isolated from the receptacle mounting hardware (per National Electrical Code, Article 250-74, Exception No. 4).
Software Accessories
*1: When printing one side of the same A4 original. *2: The optional Local Interface Kit is required. If the controller option is not specified, the optional Hard Disk must be installed on the main unit in order for the Store to HDD settings (printer driver settings), Set Numbering function (printing with distribution numbers), the Scan to HDD operation, and the box function to be used. (In order to use the Set Numbering function, the 256 MB Expanded Memory must also be installed.)
Power Requirements Max. Power Consumption Dimensions Weight Punch Unit Power Requirements Dimensions Weight
DF-621/JS-621 Specifications
Type Installation Document Alignment Supplies Option Modes Power Requirements Max. Power Consumption Dimensions Weight Job Separator Name Installation Document Alignment Modes Power Requirements Dimensions Weight Single Staple Finisher Freestanding Center Staple Cartridge Job Separator Non-Sort/ Sort/ Group/Sort Staple/ Group Staple 24 V DC (supplied from the main unit) 5 V DC (generated by Finisher) 63 W or less 21-1/4 inch (W) 38-1/2 inch (H) 25 inch (D) 84 lbs. Job separator Fixed to Finisher Center Non-Sort (in the fax or printer output mode) 5 V DC, 24 V DC (supplied from Finisher) 13-1/2 inch (W) 5-3/4 inch (H) 20-3/4 inch (D) 3-3/4 lbs.
PF-621 Specifications
Name Type Installation Document Alignment Paper Type Paper Size Capacity Power Requirements Max. Power Consumption Dimensions Weight Large Capacity Tray Front loading type paper feeder Desk type Center Plain paper 56 to 110 g/m2 (15 to 29-1/4 lb) Recycled paper 60 to 90 g/m2 (16 to 24 lb) 8-1/2 11 2,500 sheets (80 g/m2, 21-1/4 lb) 24 V DC 10 % (supplied from the main unit) 5 V DC 5 % 45 W or less 22-1/2 inch (W) 10-1/4 inch (H) 21-1/2 inch (D) 57 lbs.
DP-621 Specifications
Name Type Transport Turnover Paper Exit Installation Document Alignment Document Loading Modes Duplexing Document Processor Paper Take-Up Paper Take-Up from top of stack Endless Belt Transport Mode Loop Turnover Mode U-turn Turnover + Switchback U-Turn Turnover Mode (only in 1-Sided Mode) Mounted to the main unit with thumb scews Center Face up Standard Mode 1-Sided Mode / 2-Sided Mode Thick Paper Mode 1-Sided Mode Mixed Original Detection Mode 1-Sided Mode / 2-Sided Mode Standard Mode Plain Paper 1-Sided Mode, 35 to 128 g/m2 (9-1/4 to 34 lb) 2-Sided Mode, 50 to 110 g/m2 (13-1/4 to 29-1/4 lb) Thick Paper Mode Plain Paper 1-Sided Mode, 129 to 210 g/m2 (34-1/4 to 55-3/4 lb) Mixed Original Detection Mode Plain Paper 1-Sided / 2-Sided Mode, 50 to 110 g/m2 (13-1/4 to 29-1/4 lb)
Type of Document
DU-621 Specifications
Name Type Installation Document Alignment Paper Type Paper Size Power Requirements Max. Power Consumption Dimensions Weight Duplex Unit Switchback and Circulating Duplex Unit Mounted on the right side door of main unit Center Plain paper 60 to 90 g/m2 (16 to 24 lb) 5-1/2 8-1/2R to 12-1/4 18 24 V DC 10 % (supplied from the main unit) 5 V DC 5 % (supplied from the main unit) 17 W or less 4-1/4 inch (W) 17-1/4 inch (D) 13-1/2 inch (H) 6-1/2 lbs.
* All Specifications Subject to Change without Notice. * See the Service Manuals for Complete Specifications.
BTUs
Watts based on PPM & Pr/Hr Print Watts based on PPM & Pr/Hr Ready
(*3421.14)
Model
PPM
Prints/Hr
kW/hour
Total BTU
KM-C2230
720W 720W
186W 186W
35 35
500 1,000
171.4W 342.9W
141.7W 97.4W
0.3131 0.4403
1068.5 1502.3
Total BTUs are based on Prints per Minute, Prints per Hour, Watts based on PPM & Pr/Hr and Kw/Hour.
Watts (Copier Only) 120 V AC 10%, 60Hz 2%, 13.1A 14.30W 10% 123W 22W 720W 186W 0.1W 13.1A
INSTALLATION REQUIREMENTS
Installation Time Standard Temperature Standard Humidity Temperature Range Humidity Range Condensation and Humidity Altitude Illumination Levelness Approx 30min. (Main Body only) 73.4 F (23 C) 60%RH (Relative Humidity) 50 F ~ 87 F (10 C ~ 30 C) 15% ~ 80%RH Rapid Temperature change, Humidity drift, and condensation should be avoided Maximum 6500 ft. (2000 meters) Maximum 1,500 lux Maximum levelness: 5mm (0.2inch) The Printer must be placed on a level and sturdy surface
KM-C2230
35 /2 (With Bypass open) 30 1/4 28 11/16 247lbs. (with IU)
Allow sufficient access for proper operation and maintenance of the machine. Machine Front: 1014mm/39 7/8" Machine Rear: 1151 mm/45 1/4" *All Specifications Subject to Change without Notice.
Additional Options
The KM-C2230 is configured with a Standard built-in PCL controller. Note: When using 11 x 17 paper on the DF-626 Saddle Finisher, be sure to pull the tray out to support the longer paper.
3) IMPORTANT: Date and Time Input Both Date and Time & Present Date and Time MUST be input using the Key pad. Even if they are correct, they still must be keyed in. If you miss this step, a gray box will display on the first copy. You must then start from the beginning of the setup procedure.
KM-C2230-01 (revised) October 15, 2004 Page 18 IMPORTANT: List Output 1. Load the 1st drawer with A4L or Letter L paper. (8.5 x 11R) 2. Display the Tech. Rep. Mode screen. (For details of how to display the Tech. Rep. Mode screen, see the service manual.) 3. Select List Output. 4. Select Image Processing.
5. 6. 7. 8. 9.
Press the start key. Then, lists of various kinds will be produced. Touch END. Touch Fin. Time. Turn OFF/ON the Power Switch.
If the copier is turned OFF before completing the set-up procedure, it is necessary to start the entire procedure from the beginning. 1) The changes to the set-up procedure are effective from serial number 31102601 and above. The copier firmware is Version 28 (MSC=4036-10G0-18-00) or above. 2) The above steps must be done in the exact order and only during the initial setup. The above steps do not apply when upgrading the copier firmware or when replacing a PWB. 3) If any step is skipped, it is necessary to return to that particular step, carry out the adjustment and continue with the next step.
NOTE: