Maintenance Synchronous Line Equipment SL16 MMN


8 FauIt CIearance Procedures
At the start of the fault clearance procedure, the Blank Form for Fault Clearance
Record is copied from Section 10. Sections 10.1 and 10.2 are first completed before
the actual fault clearance procedure gets underway. The fault clearance procedures are
assigned to an alarm report using a reference number. f a number of different fault
clearance procedures are specified under point "Remedy", these are to be performed in
the specified order.
f a fault clearance procedure is unsuccessful, Sections 10.3 to 10.5 are performed. n
this case, the complete documents are sent to the Siemens service center where further
fault clearance measures are performed.
Card replacement is to be performed using the information specified in Register 9.
The fault clearance procedures are arranged according to reference numbers.
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
0100 No alarms No alarms Fault-free
system
1. No fault clearance!
Fault clearance has been completed.
0105 Power fail PPP Voltage failure
on the card
suspected as
being faulty.
1. Replace card suspected being faulty which is displayed in
the card mounting position designation.
The fault clearance procedure is complete.
0106 Power fail RRR Power fail
0110 Fuse alarm 60 V KKK Fuse alarm
60 V
Redundant
input voltage
missing.
1. Check relevant fuse in the fuse panel.
2. Fuse faulty or switched off?
f so, remedy error. The fault clearance procedure is
complete.
f not, refer to point 3.
3. Check voltage (35 V to 75 V) on the connection panel
of the subrack.
4. Voltage present?
f so, internal fault. Clarify with responsible Siemens
department.
f not, eliminate fault in the supply line.
The fault clearance procedure is complete.
0115 Supervision fail
PPP
Monitoring fault
on the card
suspected of
being faulty.
1. Replace card suspected of being faulty which is displayed
in the card mounting position designation. The fault clear-
ance procedure is complete.
0116 Supervision fail
RRR
Supervision fail
0120 Supervis. inact. Supervision
inactive
Monitoring fault
on the ZW. All
the ZW data
have been
deleted.
1. Reconfigure NE using the correct safeguarding file (main
menu "Configuration", and submenu "File r NE"). The
fault clearance procedure is complete.
0125 Card fail PPP Fault on the
card suspected
of being faulty.
1. Replace card suspected of being faulty which is displayed
in the card mounting position designation. The fault clear-
ance procedure is complete.
0126 Card fail RRR Card fail
0130 Not equipped.
Card missing
PPP
Card either
missing or not
recognized.
1. Perform a required/actual equipping comparison using
the OT (operating terminal) (main menu "Configuration",
submenu "Equipping Options" and menu option
"Compare Required/Actual Cards").
2. nsert missing card or replace unrecognized card.
The fault clearance procedure is complete.
0131 Card missing
RRR
Card missing
Tab. 8.1 Fault Clearance Procedures
8 2 S42022-L3021-H1-2-7620
MMN Maintenance Synchronous Line Equipment SL16
0135 Wrong card
type PPP
Wrong card 1. Perform a required/actual equipping comparison using
the OT (operating terminal) (main menu "Configuration",
submenu "Equipping Options" and menu option
"Compare Required/Actual Cards").
2. Check configuration or replace incorrect card. n this case,
the correct ordering No. can be determined from the loca-
tion-specific diagrams.
The fault clearance procedure ist complete.
0136 Wrong card
type RRR
Wrong card
type
0140 Date/Time stop Date/Time stop Time stopped 1. Change ABM with defective clock.
2. Transmit correct OT (operating terminal) time to the
network element after consulting the system specialist
(main menu "Maintenance" and submenu "Date/Time").
The fault clearance procedure is complete.
0145 Battery low Battery low Low battery
voltage
1. Does ABF correspond to variant S42024-L3236-A103?
f so, refer to point 2.
f not, refer to point 3.
2. nitiate battery change in ABF variant
S42024-L3236-A103 by responsible Siemens service
center. For further details, refer to point 4.
3. n the other variants, the battery compartment located on
top of the ABF is opened by undoing two securing screws.
Lift battery out of compartment and mark it.
nsert new battery (lithium battery, rated voltage 3 V,
Siemens ordering No. V42277-Z17-A1, corresponds to
type CR AA from Varta) ensuring correct polarity while
doing so!
4. Dispose of marked lithium battery properly!
5. Subsequently, check the date/time and adjust if neces-
sary, see Point 6.
6. Transfer correct time of OT (operating terminal) to
network element after clarifying with systems specialist
(main menu Maintenance and submenu Date/Time).
The fault clearance procedure is complete.
0150 Backplane-EEPROM Backpane
EEPROM fail
Backplane
EEPROM
disturbed.
1. Save configuration in file with aII options
2. Check and replace subrack EEPROM after consulting the
responsible Siemens service center.
3. Reconfigure device (set basic type, activate internal moni-
toring and transfer configuration file), see nstallation and
Test Manual (TMN).
The fault clearance procedure is complete.
0155 External alarm K External alarm
kk
External alarm 1. Define and evaluate external alarm using the location-
specific diagrams.
The fault clearance procedure is complete.
0200 Clock fail Timing source
fail
Central clock
unit faulty
1. Replace central clock unit (203-TZ-1).
The fault clearance procedure is complete.
0201 Clock fail
RRR
Timing source
fail
Clock failure in
the optical
transmitter
(OS16R).
1. Replace the optical transmitter (OS16R).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace the optical receiver (OE16R) of the same trans-
mission direction.
The fault clearance procedure is complete.
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
S42022-L3021-H1-2-7620 8 3
Maintenance Synchronous Line Equipment SL16 MMN
0210 Reference fail
KKK
SETS refer-
ence fail
Clock failure
(T3in) on the
central clock
unit.
1. Check external clock (f = 2048 kHz, U = 0.5 V to
1.9 V bal.).
2. External clock working OK?
f so, refer to point 3.
f not, perform fault clearance on external clock source.
The fault clearance procedure is complete.
3. Replace central clock unit (203-TZ-1).
The fault clearance procedure is complete.
0215 Reference fail
PPP
SETS refer-
ence fail
(RxT3)
Clock failure
(F1in) on the
central clock
unit due to the
performance or
level in the F1in
signal falling
below required
value.
1. Check the minimum performance (main menu "Mainte-
nance", submenu "Central Clock Unit") to see whether a
lower minimum performance is transmitted from the
distant station (F1 side) due to clock or reference failure.
2. s the distant station (F1 side) transmitting a lower
minimum performance?
f so, refer to point 3.
f not, refer to point 4.
3. The rest of the fault clearance procedure is performed in
the distant station. The alarms of the distant station have
to be evaluated. The fault clearance procedure on this
device is thus complete.
4. Check the optical measured values (main menu "Perform-
ance", submenu "Optical Measurements" to see whether
the receive power has diminished compared to what it
was during commissioning.
5. Has the receive power diminished?
f so, refer to point 6.
f not, refer to point 7.
6. n this case, it is necessary to check the line attenuation
and to clean the fiber-optic connectors. The fault clear-
ance procedure is complete.
7. Replace optical receiver.
The fault clearance procedure is complete.
0220 Reference fail SETS refer-
ence fail (RxLi)
Clock failure
(F2in) on the
central clock
unit due to the
performance or
level in the trib-
utary signal
falling below
required value.
1. Check the minimum performance (main menu "Mainte-
nance", submenu "Central Clock Unit") to see whether a
lower minimum performance is transmitted from the
distant station (F2 side) due to clock or reference failure.
2. s the distant station (F2 side) transmitting a lower
minimum performance?
f so, refer to point 3.
f not, refer to point 4.
3. The rest of the fault clearance procedure is performed in
the distant station. The alarms of the distant station have
to be evaluated. The fault clearance procedure on this
device is thus complete.
4. Exchange card MX4 which processes channel KKK.
The fault clearance procedure is complete
(see Tab. 5.2).
0225 Holdover SETS holdover The central
clock unit is
running in hold-
over mode due
to clock failure.
1. Process next alarm report (clock failure or reference
failure).
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
8 4 S42022-L3021-H1-2-7620
MMN Maintenance Synchronous Line Equipment SL16
0230 Loss of
synchron.
SETS
synchron. fail
Central clock
unit cannot
synchronize.
1. Replace central clock unit (203-TZ-1).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Check reference clock (T3in, F1in and F2in); refer to fault
clearance procedures 0210, 0215 and 0220.
The fault clearance procedure on this device is complete.
0235 T3out
squelched
SETS T3out
squelched
Output clock
(T3out)
suppressed by
the central
clock unit due
to the perfor-
mance falling
fallow the
required level
or due to refer-
ence failure.
1. Determine configuration for minimum performance (Q
min
)
of external synchronization clock T3out (main menu
"Configuration", submenu "Operating Parameters" and
menu option "Central Clock Unit").
2. Determine the reference in detail window "Status of
External Synchronization Clock T3 out" (main menu
"Maintenance", submenu "Central Clock Unit").
3. f the reference is T1(line) or T1(trib), the performance
level (Q
X
, X = 1 to 6) of the reference is determined from
detail window "Synchronization Status".
For reference T0, the performance level (Q
X
, X = 1 to 6)
is determined from detail window "Status of System
Clock (T0)".
4. s the performance level (Q
X
) of the reference better than
the required minimum performance (Q
min
) of T3out
(Q
X
} Q
min
)?
f not (Q
X
> Q
min
), refer to point 5.
f so, replace central clock unit.
The fault clearance procedure is complete.
5. s the reference T0?
f so, refer to point 6
f not, check clock at the corresponding distant station.
The fault clearance procedure on this device is complete.
6. Control clock pulse of T0 determined in detail window
"Status of System Clock (T0)".
7. s T3in the control clock pulse of T0?
f so, refer to point 8.
f not, check the clock at the corresponding distant station.
The fault clearance procedure on this device is complete.
8. Check the external clock source (f = 2048 kHz, U = 0.5 V
to 1.9 V bal.) and the connection.
The fault clearance procedure on this device is complete.
0300 Loss of signal Loss of signal
(RxTr)
No STM-1
signal or
140-Mbit/s
signal at F2in.
1. Determine and check connection line.
2. s the connection line working properly?
f so, refer to point 3.
f not, perform fault clearance on connection line.
3. Loop output of the relevant channel to the input.
4. Fault eliminated?
f so, refer to point 7.
f not, refer to point 5.
5. Open loop and re-establish connections.
6. Replace card MX4 which processes channel KKK
(see Tab. 5.2).
The fault clearance procedure is complete.
7. Replace transmit card at the distant station.
The fault clearance procedure at on this device is
complete.
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
S42022-L3021-H1-2-7620 8 5
Maintenance Synchronous Line Equipment SL16 MMN
0305 Loss of frame Loss of frame
(RxTr)
Loss of
synchronism
of tributary side
for STM-1
channel No. K.
1. Replace card MX4 which processes STM-1 channel
KKKKK (see Tab. 5.2).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace transmit card at the distant station.
The fault clearance procedure at on this device is
complete.
0310 B1-BER > SD B1-BER > SD
(RxTr)
Bit error ratio of
the B1 parity
byte on the trib-
utary side
exceeds the
configured
threshold
value.
1. Check the configuration of the threshold values (main
menu "AlarmStatus", submenu "SD Thresholds") against
the commissioning protocol, and correct if necessary.
2. Wrong threshold values corrected?
f so, the fault clearance procedure is complete.
f not, the threshold value is correct, refer to point 3.
3. Check connection and line attenuation on the tributary
side.
4. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 5.
5. Replace card MX4 which processes STM-1 channel
KKKKK (see Tab. 5.2).
6. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 7.
7. Check transmitter at the distant station.
The fault clearance procedure on this device is complete.
0315 B2-BER > SD B2-BER > SD
(RxTr)
Bit error ratio of
the B2 parity
byte on the trib-
utary side is
greater than
the configured
threshold
value.
1. Check the configuration of the threshold values (main
menu "AlarmStatus", submenu "SD Thresholds") against
the commissioning protocol, and correct if necessary.
2. Wrong threshold values corrected?
f so, the fault clearance procedure is complete.
f not, the threshold value is correct, refer to point 3.
3. Check connection and line attenuation on the tributary
side.
4. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 5.
5. Replace card MX4 which processes STM-1 channel
KKKKK (see Tab. 5.2).
6. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 7.
7. Check transmitter at the distant station.
The fault clearance procedure on this device is complete.
0320 B2-BER
> 10E-h3
B2-BER
> 10E-3 (RxTr)
Bit error ratio of
the B2 parity
byte on the trib-
utary side is
>10
-3
.
1. Check connection and line attenuation on the tributary
side.
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace card MX4 which processes STM-1 channel
KKKKK (see Tab. 5.2).
4. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 5.
5. Check transmitter at the distant station.
The fault clearance procedure on this device is complete.
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
8 6 S42022-L3021-H1-2-7620
MMN Maintenance Synchronous Line Equipment SL16
0325 S-AS received Section-AS
(RxTr)
Section-AS
received at trib-
utary side.
1. Process alarm from the next NE in direction of signal
source.
0330 FERF received MS-FERF
(RxTr)
Distant station
receives no
signal.
1. Check connection and line attenuation (DX4-O only).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace card DX4 which processes the channel specified
under KKKKK (see Tab. 5.2).
The fault clearance procedure is complete.
0335 Loss of Pointer Loss off Ponter
(RxTr)
nvalid pointer
value received
at tributary side
in AU4 of
STM-1 channel
No. K.
1. Replace card MX4 which processes channel KKKKK
(see Tab. 5.2).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Check transmitter at the distant station.
The fault clearance procedure on this device is complete.
0340 No AU4 No AU4 (RxTr) llegal AU type
(i.e. not AU4) in
STM-1 channel
No. KKKKK.
1. Check the setting of the distant station and replace trans-
mit card if necessary.
The fault clearance procedure is complete.
0345 P-AS received Path-AS
(RxTr)
Path-AS in the
STM-1 signal
received at trib-
utary side.
1. Fault can only be eliminated at the distant station or at an
NE earlier in the signal stream.
The fault clearance procedure on this device is complete.
0350 AS received AS (RxTr) AS in the 140-
Mbit/s signal
received at trib-
utary side.
1. Fault can only be eliminated at the distant station or at an
NE earlier in the signal stream.
The fault clearance procedure on this device is complete.
0355 Buffer fail Buffer fail
(RxTr)
Buffer (trans-
mission
memory) over-
flow/underflow.
1. Configuration of central clock unit of optical transmitter
(main menu Configuration, submenu Operating Param-
eters and menu option Central Clock Unit) and correct
if necessary.
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace card MX4 which processes channel KKKKK
(see Tab. 5.2).
4. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 5.
5. Check the transmit card and central clock unit at the
distant station and replace if necessary.
The fault clearance procedure on this device is complete.
0400 Transmit
degrad. PPP
Transmit
degraded
(TxLi)
Optical output
power is 10 dB
below the
normal output
power.
1. Replace optical transmitter specified in the card mounting
position designation.
The fault clearance procedure is complete.
0401 Transmit
degrad. RRR
0405 Transmit fail
PPP
Transmit fail
(TxLi)
Failure of the
optical signal
on the card
suspected of
being faulty.
1. Replace card suspected of being faulty which is specified
in the card mounting position designation.
The fault clearance procedure is complete.
0406 Transmit fail
RRR
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
S42022-L3021-H1-2-7620 8 7
Maintenance Synchronous Line Equipment SL16 MMN
0410 ALS active
PPP
Automatic
laser shut-
down unit
active.
1. Undo fiber-optic connection at the optical receiver and
measure the optical power at the fiber-optic connection.
Measuring duration at least 70 s.
2. Was light present for 2 s during the 70 s?
f so, refer to point 3.
f not, refer to point 5.
3. Replace optical receiver for this line.
4. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, repeat the fault clearance procedure at the distant
station.
The fault clearance procedure is complete.
5. Replace card OS16 at the distant station.
6. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, line is disturbed. Fault clearance must be performed
on the line.
The fault clearance procedure is complete.
0411 ALS active
RRR
ALS active
(TxLi)
0415 LD-bias high
PPP
Laser bias high
(TxLi)
Laser bias
current of the
optical trans-
mitter (OS16 or
OS16R) has
exceeded the
limit value.
1. Replace optical transmitter (OS16 or OS16R) specified in
the card mounting position designation.
The fault clearance procedure is complete.
0416 LD-bias high
RRR
0420 LD mod.
high PPP
Laser mod.
high (TxLi)
Laser modula-
tion current of
the optical
transmitter
(OS16 or
OS16R) has
exceeded the
limit value.
1. Replace optical transmitter (OS16 or OS16R) specified in
the card mounting position designation.
The fault clearance procedure is complete.
0421 LD mod.
high RRR
0425 LD-power
high PPP
Opt. power
high (TxLi)
Optical output
power of the
optical trans-
mitter (OS16 or
OS16R) too
high.
1. Replace optical transmitter (OS16 or OS16R) specified in
the card mounting position designation.
The fault clearance procedure is complete.
0426 LD-power
high RRR
0500 Transmit
degrad. PPP
Output level
low (TxLi)
Required
output power
on the ONV
suspected of
being faulty is
not guaran-
teed.
1. Replace ONV at port PPP. The relevant mounting position
number can be determined on the operating terminal
(main menu "Configuration", submenu "Equipping
Options" and menu option "Fiber Optical Amplifiers") or
taken from the location-specific diagrams.
The fault clearance procedure is complete.
0501 Transmit
degrad. RRR
0505 Transmit fail
PPP
Transmit fail
(TxLi)
Optical output
power on ONV
suspected of
being faulty is
under +3 dBm.
1. Replace ONV at port PPP. The relevant mounting position
number can be determined on the operating terminal
(main menu "Configuration", submenu "Equipping
Options" and menu option "Fiber Optical Amplifiers") or
taken from the location-specific diagrams.
The fault clearance procedure is complete.
0506 Transmit fail
RRR
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
8 8 S42022-L3021-H1-2-7620
MMN Maintenance Synchronous Line Equipment SL16
0510 LD-pump
high PPP
Laser pump
current (TxLi)
Laser pump
current has
exceeded the
limit value.
1. Replace ONV at port PPP. The relevant mounting position
number can be determined on the operating terminal
(main menu "Configuration", submenu "Equipping
Options" and menu option "Fiber Optical Amplifiers") or
taken from the location-specific diagrams.
The fault clearance procedure is complete.
0511 LD-pump
high RRR
0515 nput level low
PPP
nput level too
low on the card
suspected of
being faulty.
1. Check the optical measured values (main menu "Perform-
ance", submenu "Optical Measurements") to see whether
the transmit power of the optical transmitter at port PPP
lies in the required range. Details of required values can
be found in section 9 of the TED.
2. Does the optical transmit level lie in the required range?
f so, refer to point 3.
f not, refer to point 4.
. Replace ONV card suspected of being faulty at port PPP.
The relevant mounting position number can be deter-
mined on the operating terminal (main menu "Configura-
tion", submenu "Equipping Options" and menu option
"Fiber Optical Amplifiers") or taken from the location-
specific diagrams.
The fault clearance procedure is complete.
4. Replace the optical transmitter card at port PPP.
The fault clearance procedure is complete.
0516 nput level low
RRR
nput level low
(only for ONV)
0600 Output level
low PPP
Output level
too low on the
card suspected
of being faulty.
Important:
The line must
be interrupted
to eliminate the
fault!
1. Disconnect the fiber-optic connector from the input of the
OVV and use the optical level meter to measure the
output level of the line. To do this, the laser restart for test
in the SLT16 must be started at the far end if automatic
laser shutdown (LSA) is active there.
2. s the optical level > 40 dBm?
f so, refer to point 3.
f not, refer to point 4.
3. Replace OVV at port PPP. The relevant mounting position
number can be determined on the operating terminal
(main menu "Configuration", submenu "Equipping
Options" and menu option "Fiber Optical Amplifiers") or
taken from the location-specific diagrams.
The fault clearance procedure is complete.
4. Level } 40 dBm:
Check fiber attenuation of the line.
The fault clearance procedure is complete.
0601 Output level
low RRR
Output level
low (only for
OVV)
0605 LD pump
current PPP
Laser pump
current has
exceeded the
limit value.
1. Replace OVV specified in the card mounting position des-
ignation. The relevant mounting position number can be
determined on the operating terminal (main menu "Con-
figuration", submenu "Equipping Options" and menu
option "Fiber Optical Amplifier") or taken from the location-
specific diagrams.
The fault clearance procedure is complete.
0606 LD pump
current RRR
Laser pump
current (only
for OVV)
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
S42022-L3021-H1-2-7620 8 9
Maintenance Synchronous Line Equipment SL16 MMN
0700 Loss of signal
PPP
Loss of signal
(RxLi)
No receive
signal on the
line side.
1. Undo fiber-optic connection at the optical receiver and
measure the optical power at the fiber-optic connection.
Measuring duration at least 70 s.
2. Was light present for 2 s during the 70 s?
f so, refer to point 3.
f not, refer to point 5.
3. Replace optical receiver for this line.
4. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, repeat the fault clearance procedure at the distant
station.
5. Replace card OS16 at the distant station (line side).
6. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, line is faulty. Fault clearance must be performed on
the line.
The fault clearance procedure on this device is complete.
0701 Loss of signal
RRR
0705 Loss of frame
PPP
Loss of frame
(RxLi)
Loss of
synchronism
(frame
synchroniza-
tion) on the
card suspected
of being faulty.
1. Replace card suspected of being faulty which is specified
in the card mounting position designation.
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace the optical transmitter at the distant station.
The fault clearance procedure on this device is complete.
0706 Loss of frame
RRR
0710 Laser restart
PPP
Laser restart
attempt (RxLi)
Laser restart
from the distant
station.
1. Replace card OS16.
2. Fault eliminated?
f so, fault clearance procedure complete.
f not, repeat this fault clearance procedure at the distant
station.
0711 Laser restart
RRR
0715 B1-BER
> SD PPP
B1-BER
> SD (RxLi)
Bit error ratio of
the B1 parity
byte on the line
side is greater
than the config-
ured threshold
value.
1. Check the optical measured values (main menu "Perform-
ance", submenu "Optical Measurements") to see whether
the receive power has diminished compared to what it
was during commissioning.
2. Has the receive power diminished compared to what it
was during commissioning?
f so, refer to point 3.
f not, refer to point 4.
3. Check connection and line attenuation on the line side.
4. Check the configuration of the threshold values (main
menu "AlarmStatus", submenu "SD Thresholds") against
the commissioning protocol - correct if necessary.
5. Fault eliminated?
f so, the threshold is correct, the fault clearance proce-
dure is complete.
f not, refer to point 6.
6. Replace card OE16 at port PPP.
7. Fault eliminated?
f so, the fault clearance procedure is complete
f not, refer to point 8.
8. Check optical transmitter at the distant station.
The fault clearance procedure on this device is complete.
0716 B1-BER
> SD RRR
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
8 10 S42022-L3021-H1-2-7620
MMN Maintenance Synchronous Line Equipment SL16
0720 B2-BER
> 10E-3 PPP
B2-BER
> 10E-3 (RxLi)
Bit error ratio
(B2 parity byte)
on the line side
is > 10
-3
.
1. Check the optical measured values (main menu "Perform-
ance", submenu "Optical Measurements") to see whether
the receive power has diminished compared to what it
was during commissioning.
2. Has the receive power diminished compared to what it
was during commissioning?
f so, refer to point 3.
f not, refer to point 4.
3. Check connection and line attenuation on the line side.
4. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 5.
5. Replace card OE16 at port PPP.
6. Fault eliminated?
f so, the fault clearance procedure is complete
f not, refer to point 7.
7. Check transmitter at the distant station.
The fault clearance procedure on this device is complete.
0725 B2-BER
> SD PPP
B2-BER > SD
(RxLi)
Bit error ratio
(B2 parity byte)
on the line side
is greater than
the configured
threshold
value.
1. Check the optical measured values (main menu "Perform-
ance", submenu "Optical Measurements") to see whether
the receive power has diminished compared to what it
was during commissioning.
2. Has the receive power diminished compared to what it
was during commissioning?
f so, refer to point 3.
f not, refer to point 4.
3. Check connection and line attenuation on this side.
4. Check the configuration of the threshold values (main
menu "AlarmStatus", submenu "SD Thresholds") against
the commissioning protocol - correct if necessary.
5. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 6.
6. Replace card OE16 at port PPP.
7. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 8.
8. Check transmitter at the distant station.
The fault clearance procedure is complete.
0730 S-AS
received PPP
Section-AS
(RxLi)
Section AS
received.
1. Process alarm from next NE in the direction of the signal
source.
The fault clearance procedure on this device is complete.
0731 S-AS
received RRR
0735 B1 inverted
PPP
B1 inverted
(RxLi)
B1 parity byte
has been
inverted in
order to check
the monitoring
units.
1. B1 parity byte inversion can be canceled via the ABM
(control group B) or the OT (main menu Configuration,
sub menu "B1 nversion").
The fault clearance procedure is complete.
0736 B1 inverted
RRR
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
S42022-L3021-H1-2-7620 8 11
Maintenance Synchronous Line Equipment SL16 MMN
0740 FERF
received PPP
MS-FERF
(RxLi)
Distant station
on the line side
has received a
disturbed
signal. Distur-
bance has
been reported
by the distant
station by
means of the
overhead byte
(parity moni-
toring of the
multiplex
section).
1. Process next alarm or alarm at the distant station.
0745 B1-ES count
PPP
B1-ES count
high (RxLi)
Configured
B1-ES limit
value
exceeded on
the line side.
1. Check the optical measured values (main menu "Perform-
ance", submenu "Optical Measurements") to see whether
the receive power has diminished compared to what it
was during commissioning.
2. Has the receive power diminished compared to what it
was during commissioning?
f so, refer to point 3.
f not, refer to point 4.
3. Check line attenuation and clean fiber-optic connectors.
4. Check the configuration of the threshold values (main
menu "Performance", submenu "SD Thresholds") against
the commissioning protocol - correct if necessary.
5. Check F1 performance data for B1 for the presence of
error bursts (main menu "Performance", submenu
"F1 Performance Data", menu option "Regenerator
Section (B1)") and determine the cause.
0746 B1-ES count
RRR
0750 B1-SES
count PPP
B1-SES count
high (RxLi)
Configured
B1-SES limit
value has been
exceeded on
the line side.
1. Check the optical measured values (main menu "Perform-
ance", submenu "Optical Measurements") to see whether
the receive power has diminished compared to what it
was during commissioning.
2. Has the receive power diminished compared to what it
was during commissioning?
f so, refer to point 3.
f not, refer to point 4.
3. Check line attenuation and clean fiber-optic connectors.
4. Check the configuration of the threshold values (main
menu "Performance", submenu "Thresholds SES")
against the commissioning protocol - correct if necessary.
5. Check F1 performance data for B1 for the presence of
error bursts (main menu "Performance", submenu
"F1 Performance Data", menu option "Regenerator Sec-
tion (B1)") and determine the cause.
0751 B1-SES
count RRR
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
8 12 S42022-L3021-H1-2-7620
MMN Maintenance Synchronous Line Equipment SL16
0755 B2-ES count
PPP
B2-ES count
high (RxLi)
Configured
B2-ES limit
value has been
exceeded on
the line side.
1. Check the optical measured values (main menu "Perform-
ance", submenu "Optical Measurements") to see whether
the receive power has diminished compared to what it
was during commissioning.
2. Has the receive power diminished compared to what it
was during commissioning?
3. Check line attenuation and clean fiber-optic connectors.
4. Check the configuration of the threshold values (main
menu "Performance", submenu "SD Thresholds") against
the commissioning protocol - correct if necessary.
5. Check F1 performance data for B2 for the presence of
error bursts (main menu "Performance", submenu
"F1 Performance Data", menu option "Multiplex Section
(B2)") and determine the cause.
0760 B2-SES
count PPP
B2-SES
number high
(RxLi)
Configured
B2-SES limit
value has been
exceeded on
the line side.
1. Check the optical measured values (main menu "Perform-
ance", submenu "Optical Measurements") to see whether
the receive power has diminished compared to what it
was during commissioning.
2. Has the receive power diminished compared to what it
was during commissioning?
f so, refer to point 3.
f not, refer to point 4.
3. Check line attenuation and clean fiber-optic connectors.
4. Check the configuration of the threshold values (main
menu "Performance", submenu "Thresholds") against the
commissioning protocol - correct if necessary.
5. Check F1 performance data for B2 for the presence of
error bursts (main menu "Performance", submenu
"F1 Performance Data", menu option "Multiplex Section
(B2)") and determine the cause.
0765 Protection fault Protect. switch
fail
1. Check the configuration and correct if necessary.
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace the transmitter at the distant station.
The fault clearance procedure on this device is complete.
0800 Loss of frame Loss of frame
(RxLi)
Loss of
synchronism
for STM-1
channel No. K
(DX4 only).
1. Replace card DX4 which processes STM-1 channel
KKKKK (see Tab. 5.2).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace the transmitter at the distant station.
The fault clearance procedure on this device is complete.
0815 Loss of pointer Loss of pointer
(RxLi)
nvalid pointer
value received
at line side in
AU4 of STM-1
channel No. K.
1. Replace card DX4 which processes channel KKKKK
(see Tab. 5.2).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace the transmitter at the distant station.
The fault clearance procedure on this device is complete.
0820 No AU4 No AU4 (RxLi) nvalid AU type
(not AU4) in
STM-1 channel
No. K.
1. Fault can only be eliminated at the distant station or in an
NE earlier in the signal stream.
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
S42022-L3021-H1-2-7620 8 13
Maintenance Synchronous Line Equipment SL16 MMN
0825 Path-AS
received
Path-AS
(RxLi)
Path-AS in
STM-1 signal.
1. Fault can only be eliminated at the distant station or in an
NE earlier in the signal stream.
The fault clearance procedure on this device is complete.
0830 B3-BER
> 7*10E-4
B3-BER
> 7*10E-4
(RxLi)
Bit error ratio of
the B3 parity
byte on the line
side is >710
-4
in the STM-1
signal.
1. Are B1/B2 bit errors also reported?
f so, perform fault clearance for these alarm reports
(B1 or B2).
f not, refer to point 2.
2. Faults can only be eliminated in a line section or in an
NE earlier in the signal stream.
The fault clearance procedure of this device is complete.
0835 B3-BER > SD B3-BER > SD
(RxLi)
Bit error ratio of
the B3 parity
byte on the line
side is greater
than the config-
ured threshold
value in the
STM-1 signal.
1. Are B1/B2 bit errors also reported?
f so, perform fault clearance for these alarm reports
(B1 or B2).
f not, refer to point 2.
2. Check the configuration of the thresholds (main menu
"AlarmStatus", submenu "SD Thresholds") and correct if
necessary.
3. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
4. Faults can only be eliminated at the distant station or in an
NE earlier in the signal stream.
The fault clearance procedure on this device is complete.
0840 Path
unequipped
Path
unequipped
(RxLi)
Undefined VC4
path in the
STM-1 signal
on the line side.
1. The alarm report depends on the configuration. t can only
be eliminated at the distant station or in an NE earlier in
the signal stream.
The fault clearance procedure on this device is complete.
0845 FEBE-BER
> SD
Path-FEBE-
BER > SD
(RxLi)
Bit error in the
STM-1 signal
on the line side
is greater than
the configured
threshold
value.
1. Fault can only be eliminated at the distant station or in an
NE earlier in the signal stream.
0850 Path FERF Path-FERF
(RxLi)
VC4 path error
in the STM-1
signal on the
line side at the
distant station.
1. Fault can only be eliminated at the distant station or in an
NE in transmit direction.
The fault clearance procedure on this device is complete.
0855 Path trace
wrong
Path trace
wrong (RxLi)
ncorrect VC4
path received
in the STM-1
signal on the
line side.
1. Check the configuration of the path trace (main menu
"Configuration", submenu "Operating Parameters", menu
option "Path Trace") and correct if necessary.
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Faults can only be eliminated at the distant station or in an
NE earlier in the signal stream.
The fault clearance procedure on this device is complete.
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
8 14 S42022-L3021-H1-2-7620
MMN Maintenance Synchronous Line Equipment SL16
0900 Buffer fail Buffer fail
(TxTr)
Buffer (trans-
mission
memory) over-
flow/underflow
1. Compare configuration of the central clock unit (main
menu Configuration, submenu Operating Parameters,
menu option Central Clock) and correct if necessary.
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace card DX4 which processes channel KKKKK
(see Tab. 5.2).
4. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 5.
5. Check the transmit card and central clock unit at the dis-
tant station and replace if necessary.
The fault clearance procedure on this device is complete.
0905 LD-bias high Laser bias high
(TxTr)
Laser bias
current of the
optical demulti-
plexer card has
exceeded the
limit value.
1. Replace optical card DX4-O which processes channel
KKKKK (see Tab. 5.2).
The fault clearance procedure is complete.
1000 F1OH clock
failure
SOH clock
failure
1. Replace card suspected of being faulty which is displayed
in the card mounting position designation.
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Check the transmit card, central clock unit and connection
at the distant station and replace if necessary.
The fault clearance procedure on this device is complete.
1001 F1OH clock
failure RRR
F1OH clock
failure
1005 F1OH receive
fail
Receipt of error
at an interna-
tionally
defined inter-
face for SOH.
1. Check the distant station and connection.
The fault clearance procedure on this device is complete.
1006 F1OH receive
fail RRR
F1OH receive
fail
1010 F1AUX LOS
KK
Auxiliary
signal not
received
(G.703).
1. Check connection.
2. Connection faulty?
f so, eliminate fault.
The fault clearance procedure is complete.
f not, refer to point 3.
3. Check distant station.
1011 F1AUX LOS
KK RRR
Loss of signal
(RxAux)
1015 F1AUX AS KK AS (G.703)
(Channel 11,
21, 41, 12, 22
or 42)
AS in auxiliary
signal (G.703).
1. Fault at the distant station or in an upstream NE or line
section.
The fault clearance procedure on this device is complete.
1016 F1AUX AS KK
RRR
AS (G.703)
(Channel 11,
21, 12 or 22)
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
S42022-L3021-H1-2-7620 8 15
Maintenance Synchronous Line Equipment SL16 MMN
1020 F1AUX wrong progr. Wrong
channel
program
Undefined firm-
ware in the
channel
program.
1. Check the configuration of the F1 auxiliary channels (main
menu "Configuration", submenu "Operating Parameters",
menu option "F1 Auxiliary Channels") and correct if
necessary (see Tab. 8.2).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Check firmware and repeat commissioning procedure
after consulting responsible Siemens service center.
The fault clearance procedure is complete.
1100 F2OH timing
fail
F2OH timing
fail
SOH clock
failure
1. Replace card suspected of being faulty which is displayed
in the card mounting position designation.
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Check the transmit card, central clock unit and connection
at the distant station and replace if necessary.
The fault clearance procedure on this device is complete.
1105 F2OH receive
fail
F2OH receive
fail
Receipt of error
at the interna-
tionally
defined inter-
face for SOH.
1. Fault at the distant station.
The fault clearance procedure on this device is complete.
1110 F2 AUX LOS
KK
Los of signal
(RxAux)
Auxiliary
signal not
received
(G.703).
1. Check connection.
2. Connection faulty?
f so, eliminate fault.
The fault clearance procedure is complete.
f not, refer to point 3.
3. Check distant station.
1115 F2AUX AS KK AS (G.703)
(Channel 1
or 2)
AS in auxiliary
signal (G.703).
1. Fault at the distant station or in an upstream NE or line
section.
The fault clearance procedure on this device is complete.
1120 F2AUX wrong
prog.
Wrong
channel
program
Undefined firm-
ware in the
channel
program.
1. Check the configuration of the F1 auxiliary channels (main
menu "Configuration", submenu "Operating Parameters",
menu option "F1 Auxiliary Channels") and correct if
necessary (see Tab. 8.3).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Check firmware and repeat commissioning procedure
after consulting responsible Siemens service center.
The fault clearance procedure is complete.
1205 SW download error KKK SW download
error
Error during
SW download
operation.
1. Repeat software loading procedure.
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, contact the responsible Siemens service center.
1210 Routing data err. KKK Routing-data
error
Error in the
routing data.
1. Reload routing tables (main menu "Configuration",
submenu "File r NE") with category "Routing Tables
MCF-Qx", see Operating Manual (OMN).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, contact the responsible Siemens service center.
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)
8 16 S42022-L3021-H1-2-7620
MMN Maintenance Synchronous Line Equipment SL16
1220 nterface fault KKK nterface fault Fault at the
DCC or Q inter-
face.
The interface
concerned is
displayed via a
code number in
the alarm
report. The
code number is
displayed
in field KKK
on the ABM,
in column K
on the OT.
The signifi-
cance of the
code numbers
is shown in
Tab. 8.4.
With code
numbers 8 to
11, it is
possible to
determine the
selected F2
port for each
tributary group
on the oper-
ating terminal.
Menu path:
Configura-
tion/Operating
Parame-
ters/F2 Auxil-
iary Channels.
1. Check the configuration of the DCC settings (main menu
"Configuration", submenu "DCC Settings") and/or Qx
settings.
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 3.
3. Replace the card assigned to the code.
4. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, refer to point 5.
5. Check the interface at the distant station.
The fault clearance procedure on this device is complete.
6. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, check DCN or TMN.
The fault clearance procedure on this device is complete.
1225 NSAP address KKK NSAP address
mismatch
NSAP address
incorrectly
configured.
1. Repeat configuration procedure, refer to nstallation and
Test Manual (TMN).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, contact the responsible Siemens service center.
1230 DCC config. wrong KKK DCC config.
mismatch
DCC interface
configured
incorrectly.
1. Repeat the configuration procedure (main menu "Config-
uration, submenu "DCC Settings"), see nstallation and
Test Manual (TMN).
2. Fault eliminated?
f so, the fault clearance procedure is complete.
f not, contact the responsible Siemens service center.
1250 Message No. KK Event report nn Signaling of a
non-specified
standard
report.
1. Contact the responsible Siemens service center.
The fault clearance procedure is complete.
Ref.-
Nr.
ABM-Message OT-Message Cause Remedy
SLT1/16 SLR16
Tab. 8.1 Fault Clearance Procedures (Cont.)