Beruflich Dokumente
Kultur Dokumente
N
C
C
O
M
Reset
+ G
N
1 NN O
2 DO
V
Probe
N
C
C
O
M
10/100Base-T
Outlet
Amperage
C
O
M
10/100
AP9619 Network Management Card EM
TVSS
GND
15A
Outlets
Input Block & Cover
Outlet Circuit Breakers
EBM Connection Block
Output Pwr
Zone
1
N
O
C
O
M
Reset
N
C
+ G
N
1 NN O
2 DO
V
Zone
1
N
O
www.apcc.com
Probe
C
O
M
N
C
10/100Base-T
Breaker
Amperage
C13
C13
C13
C13
C19
10A
10A
10A
10A
16A
C13
C13
C13
C13
C19
L1
C
O
M
10/100
www.apcc.com
L2
L3
Outlet Type
15A
AC to DC
then
DC to AC
10A
10A
10A
10A
16A
?A Fuse
380V
400V
415V
TVSS
GND
RECTIFIER
DC LINK
TVSS
GND
AC SOURCE
LOAD
BATTERY
CHARGER
NORMAL POWER FLOW
STORED ENERGY POWER FLOW
RECHARGE ENERGY FLOW
TVSS
GND
BATTERY
Authors:
William S. Champion
wchamp@us.ibm.com
Matthew R. Archibald
archibam@us.ibm.com
Mitchell Walker
mitchelw@us.ibm.com
Version: 1.4.0
Date: October 26, 2010
The user of this document is responsible for obtaining the latest copy prior to use. Obsolete copies may be
archived and used for reference purposes only. The latest version of this document is located at:
http://www-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/WP101655
Initial Release
Updated sections Introduction, How To Use This Guide, Input Connection Block
for IBM UPS7500/10000, IBM System x Server Label Rating, IBM Storage Label
Rating, IEC 309 Pin & Sleeve Plug Decode, and IEC 320 Connectors. Modified
run times to be all in minutes. Added Some Background on Power Factor and
UPS Sizing section.
Added new rack mounted IBM UPS1500, IBM UPS2200, and IBM UPS3000,
new line cords
Update Helpful Links section. Updated Line Cords and Plugs section. Added
new rack mounted IBM UPS6000.
Add new IBM UPS1000/1500 tower models.
Contributors
Marc Hollingsworth MarcHHollingsworth@Eaton.com
Manager, Global Accounts Eaton http://www.eaton.com/ibm
Ben Hilmus bhilmus@us.ibm.com
World Wide Product Marketing Manager IBM Systems x
Preston Miller prmiller@apcc.com
Global Program Manager American Power Conversion (APC) http://www.apc.com
Notices:
This paper is intended to provide information regarding IBM System x Power Uninterruptable Power Supply (UPS). It discusses findings
based on configurations that were created and tested under laboratory conditions. These findings may not be realized in all customer
environments, and implementation in such environments may require additional steps, configurations and performance analysis. The
information herein is provided AS IS with no warranties, express or implied. This information does not constitute a specification or form part
of the warranty for any IBM or non-IBM products.
Information in this document was developed in conjunction with the use of the equipment specified and is limited in application to those
specific hardware and software products and levels.
The information contained in this document has not been submitted to any formal IBM test and is distributed as is. The use of this information
or the implementation of these techniques is a customer responsibility and depends on the customers ability to evaluate and integrate them
into the customers operational environment. While each item may have been reviewed by IBM for accuracy in a specific situation, there is no
guarantee that the same or similar results will be obtained elsewhere. Customers attempting to adapt these techniques to their own
environments do so at their own risk.
IBM may not officially support techniques mentioned in this document. For questions regarding officially supported techniques, please refer to
the product documentation, announcement letters or contact the IBM Support Line at 1-800-IBM-SERV.
This document makes references to vendor-acquired applications or utilities. It is the customer responsibility to obtain licenses of these utilities
prior to their usage.
Copyright International Business Machines Corporation 2010. All rights reserved. U.S. Government Users Restricted Rights Use,
duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
Page |2
Table of Contents
TABLE OF CONTENTS ........................................................................................................................................................... 3
INTRODUCTION ................................................................................................................................................................... 6
HOW TO USE THIS GUIDE .............................................................................................................................................................. 6
IBM UPS QUICK VIEW .......................................................................................................................................................... 7
IBM UPS1000 TOWER NEW ............................................................................................................................................. 8
Optional Accessories ........................................................................................................................................................... 8
SELECTABLE LINE CORDS IBM UPS1000 TOWER (230V) ................................................................................................................ 9
OUTLET DIAGRAM IBM UPS1000 TOWER (100/120V) ............................................................................................................... 10
Logical Layout IBM UPS1000 Tower (100/120V)............................................................................................................ 10
OUTLET DIAGRAM IBM UPS1000 TOWER (230V)....................................................................................................................... 11
Logical Layout IBM UPS1000 Tower (230V) ................................................................................................................... 11
RUN TIME IBM UPS1000 TOWER ............................................................................................................................................. 12
IBM UPS1500 TOWER NEW ........................................................................................................................................... 13
Optional Accessories ......................................................................................................................................................... 13
SELECTABLE LINE CORDS IBM UPS1500 TOWER .......................................................................................................................... 14
OUTLET DIAGRAM IBM UPS1500 TOWER (120V)....................................................................................................................... 15
Logical Layout IBM UPS1500 Tower (120V) ................................................................................................................... 15
OUTLET DIAGRAM IBM UPS1500 TOWER (100V)....................................................................................................................... 16
Logical Layout IBM UPS1500 Tower (100V) ................................................................................................................... 16
OUTLET DIAGRAM IBM UPS1500 TOWER (230V)....................................................................................................................... 17
Logical Layout IBM UPS1500 Tower (230V) ................................................................................................................... 17
RUN TIME IBM UPS1500 TOWER ............................................................................................................................................. 18
IBM UPS1000/1500 TOWER OLD ..................................................................................................................................... 19
SELECTABLE LINE CORDS UPS1000/1500THV ............................................................................................................................ 20
OUTLET DIAGRAM IBM UPS1000/1500 LOW VOLTAGE............................................................................................................... 20
Logical Layout IBM UPS1000 Low Voltage ..................................................................................................................... 20
Logical Layout IBM UPS1500 Low Voltage ..................................................................................................................... 21
OUTLET DIAGRAM IBM UPS1000/1500 HIGH VOLTAGE .............................................................................................................. 21
Logical Layout IBM UPS1000 High Voltage .................................................................................................................... 21
Logical Layout IBM UPS1500 High Voltage .................................................................................................................... 22
RUN TIME IBM UPS1000/1500 .............................................................................................................................................. 22
IBM UPS1500 RACK MOUNTED (RM) .............................................................................................................................. 23
Optional Accessories ......................................................................................................................................................... 23
SELECTABLE LINE CORDS IBM UPS1500 RM .............................................................................................................................. 24
OUTLET DIAGRAM IBM UPS1500 RM 100/120V ...................................................................................................................... 24
Logical Layout IBM UPS1500 RM 100/120V .................................................................................................................. 24
OUTLET DIAGRAM IBM UPS1500 RM 230V.............................................................................................................................. 25
Logical Layout IBM UPS1500 RM 230V .......................................................................................................................... 25
RUN TIME IBM UPS1500 RM ................................................................................................................................................. 25
IBM UPS2200 RACK MOUNTED (RM) .............................................................................................................................. 26
Optional Accessories ......................................................................................................................................................... 26
SELECTABLE LINE CORDS IBM UPS2200 RM .............................................................................................................................. 27
OUTLET DIAGRAM IBM UPS2200 RM 100/120V ...................................................................................................................... 28
Logical Layout IBM UPS2200 RM 100/120V .................................................................................................................. 28
OUTLET DIAGRAM IBM UPS2200 RM 230V.............................................................................................................................. 29
Logical Layout IBM UPS2200 RM 230V .......................................................................................................................... 29
RUN TIME IBM UPS2200 RM 100/120V .............................................................................................................................. 29
RUN TIME IBM UPS2200 RM 230V ...................................................................................................................................... 30
Page |3
Page |5
Introduction
The Uninterruptible Power Supply (UPS) systems covered in this guide are those that are currently marketed
worldwide. The intent of this guide is to provide UPS information when needed when planning power for System
x and BladeCenter solutions.
This guide is best used in softcopy form since it contains hyperlinks for navigation. This document can still be
used in hardcopy as reference only. You can obtain the latest copy of this document by sending an email to
wchamp@us.ibm.com or archibam@us.ibm.com (put Latest UPS Guide in the subject line).
For more information about how to size and plan for UPS systems, see the Background on Power Factor and
UPS Sizing section on page 65 of this document.
Page |6
Option
Number
53961AX
7
53961JX
8
53961KX
2130R3X
UPS1000
Tower Old
2130R4X
7
2130R8X
UPS1500
Tower New
53962AX
7
53962JX
8
53962KX
2130R5X
UPS1500
Tower Old
2130R6X
7
2130R9X
UPS1500
Rack
UPS2200
Rack
UPS3000
Rack
UPS5000
Rack
UPS6000
Rack New
53951AX
53951KX
10A
Output
Voltage
120V 1ph
100V 1ph
230V 1ph
10A
750W / 3.75A
Outlets
1
8 / 5-15
1
8 / 5-15
5
8 / C13
120V 1ph
700W / 7A
8 / 5-15
5A
200240V 1ph
700W / 3.5A
8 / C13
10A
100V 1ph
700W / 7A
8 / 5-15
12A
16A
10A
120V 1ph
100V 1ph
230V 1ph
15A
12A
Output W / Amperage
750W / 7.5A
1050W / 10.5A
8 / 5-15
7.5A
200240V 1ph
1050W / 5.25A
8 / C13
15A
100V 1ph
1050W / 10.5A
8 / 5-15
7.5A
53952KX
230V 1ph
53953AX
1000W / 5A
10A
230V 1ph
1920W / 9.6A
100-127V
1ph
24A
120V 1ph
100V 1ph
53953JX
200V 1ph
208V 1ph
16A
200V 1ph
208V 1ph
2700W / 13.5A
53953KX
230V 1ph
16A
230V 1ph
2700W / 13.5A
53956AX
53956KX
230V 1ph
200V 1ph
200-240V
1ph
380-415V
8
3ph Wye
200V 1ph
200-240V
1ph
380-415V
8
3ph Wye
21303RX
21304JX
21304RX
25A
30A
30A
200240V 1ph
200V 1ph
208V 1ph
13
19
1
1
1000W / 10A
200-240V
1ph
200V 1ph
208V 1ph
19
120V 1ph
120V 1ph
100V 1ph
230V 1ph
1000W / 10A
120V 1ph
100V 1ph
24195KX
1000W / 5A
13A
Page
8 / 5-15
2
8 / 5-20
5
8 / C13
16A
UPS10000
Rack
Max Input
Amperage
100-127V
1ph
53952AX
21303JX
UPS7500
Rack
Input
Voltage
120V 1ph
100V 1ph
230V 1ph
100-127V
1ph
200-240V
1ph
100-127V
1ph
120V 1ph
100V 1ph
230V 1ph
100-127V
1ph
200-240V
1ph
100-127V
1ph
100-127V
1ph
230V 1ph
4500W / 22.5A
5600W / 28A
230V 1ph
4 / 5-15
5
2 / C13
5
4 / C13
2
6 / 5-20
5
2 / C13
6
2 / C19
5
8 / C13
6
2 / C19
2
2 / 5-20
3
1 / L5-20
5
2 / C13
6
2 / C19
4
1 / L6-20
5
2 / C13
6
2 / C19
5
8 / C13
6
2 / C19
5
8 / C13
6
2 / C19
9
2 / L6-30
6
4 / C19
5
6 / C13
6
4 / C19
23
26
31
37
40
200V 1ph
38A
14A
200240V 1ph
6000W / 30A
4 / C19
45
8000W / 40A
4 / C19
45
200V 1ph
50A
18A
200240V 1ph
Page |7
Part Number
Feature Code
EBMs Supported
EPO Connection
Power Factor
UPS Type
Supported Country or Region
Input
Line Cord
Voltage Range
Max Current
Phase / Frequency
Surge Energy Rating
Output
Watts
Nominal Voltage
Back
53961AX (120V)
53961JX (100V)
Back
53961KX (230V)
UPS1000 120V
5396-1AX
5396-TU1 (FC 6663)
None
Yes
0.75
Line Interactive
North America
120V
detachable 4.3m,
NEMA 5-15P
84-121V for 100V
97-145V for 120V
12A
1ph / 50 or 60Hz.
1200 joules
120V
750W
UPS1000 100V
5396-1JX
None
Yes
0.75
Line Interactive
Japan
100V
detachable 4.3m,
NEMA 5-15P
84-121V for 100V
97-145V for 120V
12A
1ph / 50 or 60Hz.
1200 joules
100V
750W
120V (Configurable)
100V (Configurable)
7.5A
8 x NEMA 5-15R
7.5A
8 x NEMA 5-15R
Maximum Amperage
Receptacles
UPS1000 230V
5396-1KX
None
Yes
0.75
Line Interactive
International
230V
Selectable
160V-286V for 230V
10A
1ph / 50 or 60Hz.
2400 joules
230V
750W
220, 230, or 240V
(Configurable)
3.75A
8 x IEC 320 C13
Optional Accessories
Network Management Card (NMC)
P/N: 46M4110 FC: 6145
Page |8
4.3m
Line Cord
81Y2376
81Y2382
81Y2390
81Y2381
81Y2380
81Y2379
81Y2377
81Y2383
81Y2385
81Y2386
81Y2378
81Y2388
81Y2389
81Y2387
81Y2384
Plug Type
CEE7-VII
DK2-5a
SEV 1011-S24507
SI 32
CEI 23-16
SABS 164
BS 1363/A
AS/NZS 3112
KSC 8305
IS6538
GB 2099.1
CNS 10917 (125V)
CNS 10917 (250V)
NBR 6147
IRAM 2073
Country or Region
Europe
Denmark
Switzerland
Israel
Italy
South Africa
United Kingdom
Australia / New Zealand
South Korea
India
China
Taiwan
Taiwan
Brazil
Argentina
Page |9
Remote emergency
power-off port
RS-232
Connector
USB
2 NEMA 5-15P
(Load Segment 1)
6 NEMA 5-15P
(Load Segment 2)
Detachable
Line Cord
AC to DC
then
DC to AC
5-15
5-15
15A
15A
15A
15A
15A
15A
5-15
5-15
5-15
5-15
5-15
5-15
Input Line
Outlet Type
P a g e | 10
Optional
NMC Bay
Remote emergency
power-off port
RS-232
Connector
USB
AC to DC
then
DC to AC
C13
C13
10A
10A
10A
10A
10A
10A
C13
C13
C13
C13
C13
C13
Input Line
Outlet Type
P a g e | 11
Load (W)
188
375
573
750
Internal
Batteries
25
15
7
6
P a g e | 12
Part Number
Feature Code
EBMs Supported
EPO Connection
Power Factor
UPS Type
Supported Country or Region
Input
Line Cord
Voltage Range
Max Current
Phase / Frequency
Surge Energy Rating
Output
Watts
Nominal Voltage
Back
53962AX (120V)
Back
53962JX (100V)
UPS1500 120V
5396-2AX
5396-TU2 (FC 6666)
None
Yes
0.7
Line Interactive
North America
120V
detachable 2.8m,
NEMA 5-15P
97-145V
12A
1ph / 50 or 60Hz.
1200 joules
120V
1000W
UPS1500 100V
5396-2JX
None
Yes
0.7
Line Interactive
Japan
100V
detachable 2.5m,
NEMA 5-20P
84-121V
16A
1ph / 50 or 60Hz.
1200 joules
100V
1000W
120V (Configurable)
100V (Configurable)
10A
8 x NEMA 5-15R
10A
8 x NEMA 5-15R
Maximum Amperage
Receptacles
Back
53962KX (230V)
UPS1500 230V
5396-2KX
None
Yes
0.7
Line Interactive
International
230V
Selectable
160V-286V
10A
1ph / 50 or 60Hz.
2400 joules
230V
1000W
220, 230, or 240V
(Configurable)
5A
8 x IEC 320 C13
Optional Accessories
Network Management Card (NMC)
P/N: 46M4110 FC: 6145
P a g e | 13
4.3m
Line Cord
81Y2376
81Y2382
81Y2390
81Y2381
81Y2380
81Y2379
81Y2377
81Y2383
81Y2385
81Y2386
81Y2378
81Y2388
81Y2389
81Y2387
81Y2384
Plug Type
CEE7-VII
DK2-5a
SEV 1011-S24507
SI 32
CEI 23-16
SABS 164
BS 1363/A
AS/NZS 3112
KSC 8305
IS6538
GB 2099.1
CNS 10917 (125V)
CNS 10917 (250V)
NBR 6147
IRAM 2073
Country or Region
Europe
Denmark
Switzerland
Israel
Italy
South Africa
United Kingdom
Australia / New Zealand
South Korea
India
China
Taiwan
Taiwan
Brazil
Argentina
P a g e | 14
Remote emergency
power-off port
RS-232
Connector
USB
2 NEMA 5-15P
(Load Segment 1)
6 NEMA 5-15P
(Load Segment 2)
Detachable
Line Cord
AC to DC
then
DC to AC
5-15
5-15
15A
15A
15A
15A
15A
15A
5-15
5-15
5-15
5-15
5-15
5-15
Input Line
Outlet Type
P a g e | 15
Remote emergency
power-off port
RS-232
Connector
USB
2 NEMA 5-20P
(Load Segment 1)
6 NEMA 5-20P
(Load Segment 2)
Detachable
Line Cord
AC to DC
then
DC to AC
5-20
5-20
20A
20A
20A
20A
20A
20A
5-20
5-20
5-20
5-20
5-20
5-20
Input Line
Outlet Type
P a g e | 16
Optional
NMC Bay
Remote emergency
power-off port
RS-232
Connector
USB
AC to DC
then
DC to AC
C13
C13
10A
10A
10A
10A
10A
10A
C13
C13
C13
C13
C13
C13
Input Line
Outlet Type
P a g e | 17
Load (W)
255
510
750
970
Internal
Batteries
36
15
9
6
P a g e | 18
Part Number
EBMs
Supported
EPO
Connection
Power Factor
UPS Type
Input
Supported
Region
Line Cord
Voltage
VA
Max Current
Phase /
Frequency
Output
Watts
Nominal
voltage
Max Current
Receptacles
UPS1000/1500
THV Back
UPS1000TLV
2130R3X
UPS1000THV
2130R4X
UPS1000TJV
2130R8X
UPS1500TLV
2130R5X
UPS1500THV
2130R6X
UPS1500TJV
2130R9X
None
None
None
None
None
None
None
None
None
None
None
None
0.7
Double
Conversion
Low Voltage
0.7
Double
Conversion
High Voltage
0.7
Double
Conversion
Japan
0.7
Double
Conversion
Low Voltage
0.7
Double
Conversion
High Voltage
0.7
Double
Conversion
Japan
Japan
Japan
200-240V
1000 VA
5A
1ph /
50 or 60Hz.
High Voltage
700 W
Attached 6ft,
NEMA 5-15P
100-127V
1000 VA
10A
1ph /
50 or 60Hz.
Japan
700 W
Attached 6ft,
NEMA 5-15P
100-127V
1500 VA
15A
1ph /
50 or 60Hz.
Low Voltage
1050 W
200-240V
1500 VA
7.5A
1ph /
50 or 60Hz.
High Voltage
1050 W
Attached 6ft,
NEMA 5-15P
100-127V
1500 VA
15A
1ph /
50 or 60Hz.
Japan
1050 W
120V
200-240V
100V
120V
200-240V
100V
7A
8 / 5-15R
3.5A
8 / C13
7A
8 / 5-15R
10.5A
8 / 5-15R
5.25A
8 / C13
10.5A
8 / 5-15R
Selectable
Selectable
P a g e | 19
Plug Type
CEE7-VII
DK2-5a
SEV 1011-S24507
SI 32
CEI 23-16
SABS 164
BS 1363/A
AS/NZS 3112
KSC 8305
IS6538
GB 2099.1
NBR 6147
IRAM 2073
Country or Region
Europe
Denmark
Switzerland
Israel
Italy
South Africa
United Kingdom
Australia / New Zealand
South Korea
India
China
Brazil
Argentina
Outlets
AC to DC
then
DC to AC
15A
15A
15A
15A
15A
15A
15A
15A
15A
Input Line
5-15
5-15
5-15
5-15
5-15
5-15
5-15
5-15
Outlet Type
P a g e | 20
20A
AC to DC
then
DC to AC
15A
15A
15A
15A
15A
15A
15A
15A
Input Line
5-15
5-15
5-15
5-15
5-15
5-15
5-15
5-15
Outlet Type
Outlets
Input Line Cord Connector
AC to DC
then
DC to AC
15A
10A
10A
10A
10A
10A
10A
10A
10A
Input Line
C13
C13
C13
C13
C13
C13
C13
C13
Outlet Type
Input = 5A 200-240V
P a g e | 21
AC to DC
then
DC to AC
20A
10A
10A
10A
10A
10A
10A
10A
10A
Input Line
C13
C13
C13
C13
C13
C13
C13
C13
Outlet Type
Runtime (minutes)
UPS1000T
UPS1500T
224
269
127
157
64
80
41
51
29
37
23
28
18
22
15
18
13.5
16.5
12
15
11
13
8
11
9
7.4
6.7
P a g e | 22
Part Number
Feature Code
EBMs Supported
U Space
EPO Connection
Power Factor
UPS Type
Supported Country or Region
Input
Line Cord
Voltage Range
Max Current
Phase / Frequency
Surge Energy Rating
Output
Watts
Nominal Voltage
Maximum Amperage
Receptacles
UPS1500 100/120V
5395-1AX
5395-RU1 (FC 6653)
None
2
Yes
0.7
Line Interactive
North America, Japan
100/120V
detachable 4.3m,
NEMA 5-15P
84-121V for 100V
97-145V for 120V
13A
1ph / 50 or 60Hz.
1200 joules
100/120V
1000W
100V, 120V
(Configurable)
10A
4 x NEMA 5-15R
2 x IEC 320 C13
UPS1500 230V
5395-1KX
5395-RU1 (FC 6654)
None
2
Yes
0.7
Line Interactive
World Wide
230V
Selectable
160V-286V for 230V
7.5A
1ph / 50 or 60Hz.
2400 joules
230V
1000W
220, 230, or 240V
(Configurable)
5A
4 x IEC 320 C13
Optional Accessories
Network Management Card (NMC)
P/N: 46M4110 FC: 6145
P a g e | 23
4.3m
Line Cord
81Y2376
81Y2382
81Y2390
81Y2381
81Y2380
81Y2379
81Y2377
81Y2383
81Y2385
81Y2386
81Y2378
81Y2388
81Y2389
81Y2387
81Y2384
Plug Type
CEE7-VII
DK2-5a
SEV 1011-S24507
SI 32
CEI 23-16
SABS 164
BS 1363/A
AS/NZS 3112
KSC 8305
IS6538
GB 2099.1
CNS 10917 (125V)
CNS 10917 (250V)
NBR 6147
IRAM 2073
Country or Region
Europe
Denmark
Switzerland
Israel
Italy
South Africa
United Kingdom
Australia / New Zealand
South Korea
India
China
Taiwan
Taiwan
Brazil
Argentina
Ground Screw
Optional
NMC Bay
Remote emergency
power-off port
USB
RS-232
Connector
4 NEMA 5-15R
(Load Segment 1)
AC to DC
then
DC to AC
C13
C13
15A
15A
15A
15A
5-15
5-15
5-15
5-15
Input Line
Outlet Type
P a g e | 24
Detachable
Line Cord
Ground
Screw
Remote emergency
power-off port
USB
RS-232
2 IEC320 C13
(Load Segment 1)
2 IEC320 C13
(Load Segment 2)
C13
C13
15A
15A
C13
C13
Outlet Type
AC to DC
then
DC to AC
Input Line
Load (W)
250
500
750
1000
Internal
Batteries
14
11
7
5
P a g e | 25
Part Number
Feature Code
EBMs Supported
U Space
EPO Connection
Power Factor
UPS Type
Supported Country or
Region
Input
Line Cord
Voltage Range
Max Current
Phase / Frequency
Surge Energy Rating
Output
Watts
Nominal Voltage
Maximum Amperage
Receptacles
UPS2200 100/120V
5395-2AX
5395-RU2 (FC 6655)
1
2
Yes
1.0
Line Interactive
UPS2200 230V
5395-2KX
5395-RU2 (FC 6656)
1
2
Yes
0.96
Line Interactive
EBM
46M4108
5395-RU2 (FC 5732)
2
-
World Wide
100/120V
Detachable 4.3m,
NEMA 5-20P
84-121V for 100V
97-145V for 120V
16A
1ph / 50 or 60Hz.
1200 joules
100/120V
1500W @ 100V
(Japan)
1920W @ 120V
(North America)
100V, 120V
(Configurable)
16A @ 100V
16A @ 120V
6 x NEMA 5-20R
2 x IEC 320 C19
2 x IEC 320 C13
230V
EBM
Selectable
10A
1ph / 50 or 60Hz.
2400 joules
230V
EBM
1920W
9.6A
2 x IEC 320 C19
8 x IEC 320 C13
Optional Accessories
Network Management Card (NMC)
P/N: 46M4110 FC: 6145
P a g e | 26
4.3m
Line Cord
81Y2376
81Y2382
81Y2390
81Y2381
81Y2380
81Y2379
81Y2377
81Y2383
81Y2385
81Y2386
81Y2378
81Y2388
81Y2389
81Y2387
81Y2384
Plug Type
CEE7-VII
DK2-5a
SEV 1011-S24507
SI 32
CEI 23-16
SABS 164
BS 1363/A
AS/NZS 3112
KSC 8305
IS6538
GB 2099.1
CNS 10917 (125V)
CNS 10917 (250V)
NBR 6147
IRAM 2073
Country or Region
Europe
Denmark
Switzerland
Israel
Italy
South Africa
United Kingdom
Australia / New Zealand
South Korea
India
China
Taiwan
Taiwan
Brazil
Argentina
P a g e | 27
USB
Remote emergency
power-off port
Optional
NMC Bay
RS-232
Connector
6 6 NEMA 5-20R
(Load Segment 1)
Optional EBM
Connector
Detachable
Line Cord
AC to DC
then
DC to AC
C13
C13
20A
20A
20A
20A
20A
20A
16A
16A
5-20
5-20
5-20
5-20
5-20
5-20
C19
C19
Input Line
Outlet Type
P a g e | 28
Remote emergency
power-off port
USB
Optional
NMC Bay
Ground Screw
RS-232
Connector
Optional EBM
Connector
Detachable
Line Cord
AC to DC
then
DC to AC
10A
10A
C13
C13
10A
10A
10A
10A
10A
10A
16A
16A
C13
C13
C13
C13
C13
C13
C19
C19
Input Line
Outlet Type
Load (W)
500
969
1450
1920
Internal
Batteries
42
18
11
7
+1
143
66
43
28
P a g e | 29
Load (W)
500
968
1450
1920
Internal
Batteries
41
17
10
7
+1
138
64
40
28
P a g e | 30
Part Number
Feature Code
EBMs Supported
U Space
EPO Connection
Power Factor
UPS Type
Supported Country
or Region
Input
Line Cord
Voltage Range
Max Current
Phase / Frequency
Surge Energy Rating
Output
Watts
Nominal Voltage
Maximum Amperage
Receptacles
UPS3000 100/120V
5395-3AX
5395-RU3 (FC 6657)
1
3
Yes
0.9
Line Interactive
UPS3000 200/208V
5395-3JX
5395-RU3 (FC 6658)
1
3
Yes
0.9
Line Interactive
UPS3000 230V
EBM
5395-3KX
69Y1982
5395-RU3 (FC 6659) 5395-RU3 (FC 5733)
1
3
3
Yes
0.9
Line Interactive
-
World Wide
100/120V
Attached 2.0m,
NEMA L5-30P
84-121V for 100V
97-145V for 120V
24A
1ph / 50 or 60Hz.
1200 joules
100/120V
2300W @ 100V
(Japan)
2700W @ 120V
(North America)
100V, 120V
(Configurable)
22.5A @ 100V
22.5A @ 120V
1 x NEMA L5-20R
2 x NEMA 5-20R
2 x IEC 320 C19
2 x IEC 320 C13
200/208V
Detachable
NEMA L6-20P
230V
EBM
Selectable
16A
1ph / 50 or 60Hz.
2400 joules
200/208V
16A
1ph / 50 or 60Hz.
2400 joules
230V
EBM
2700W
2700W
208V
(Configurable)
13.5A
13.5A
2 x NEMA L6-20R
2 x IEC 320 C19
2 x IEC 320 C13
Optional Accessories
Network Management Card (NMC)
P/N: 46M4110 FC: 6145
P a g e | 31
Plug Type
CEE7-VII
BS 1363/A w/13A fuse
CEI 23-16
IEC 309-P+N+G
SABS 164
SI 32
NEMA L6-20P
AS/NZS 3112
GB 2099.1
IS 6538
IRAM 2073
CNS 10917 (250V)
KSC 8305
NBR 14136
SEV 1011 T23
Country or Region
Europe
UK
Italy
Dmk/Swiss
S Africa
Israel
North America & Japan
Australia/NZ
China
India
Argentina
Taiwan
Korea
Brazil
Switzerland
P a g e | 32
RS-232
Connector
Ground
Screw
Fixed 2.0m
NEMA L5-30P
Line Cord
Output Circuit
Breakers
USB
Optional
NMC Bay
Optional EBM
Connector
2 NEMA 5-20R
(Load Segment 1)
1 NEMA L5-20R
(Load Segment 1)
2 IEC 320 C19
(Load Segment 1)
AC to DC
then
DC to AC
20A
10A
10A
C13
C13
20A
20A
16A
16A
20A
5-20
5-20
C19
C19
L5-20
Input Line
Outlet Type
P a g e | 33
Detachable
Line Cord
USB
Ground
Screw
RS-232
Connector
2 NEMA L6-20R
(Load Segment 1)
Optional EBM
Connector
AC to DC
then
DC to AC
C13
C13
16A
16A
20A
20A
C19
C19
L6-20
L6-20
Input Line
Outlet Type
P a g e | 34
Detachable
Line Cord
USB
RS-232
Connector
Ground
Screw
Optional EBM
Connector
AC to DC
then
DC to AC
10A
10A
C13
C13
10A
10A
10A
10A
10A
10A
16A
16A
C13
C13
C13
C13
C13
C13
C19
C19
Input Line
Outlet Type
Load (W)
678
1350
2060
2700
Internal
Batteries
42
16
10
7
+1
156
62
42
27
P a g e | 35
Load (W)
660
1340
2040
2680
Internal
Batteries
41
17
10
6
+1
153
68
43
29
Load (W)
670
1350
2020
2680
Internal
Batteries
41
17
10
7
+1
156
81
41
27
P a g e | 36
Model
Part Number
Feature Code
EBMs Supported
EPO Connection
Power Factor
UPS Type
Input
Line Cord
Voltage
VA
Max Current
Phase / Frequency
Output
Watts
Nominal voltage
Maximum Amperage
Receptacles
UPS5000XHV
24195KX
Not applicable
4
Yes
0.9
Double Conversion
UPS5000XHV
Selectable
200-240V
5000
30A
1ph / 50 or 60Hz.
UPS5000XHV
4500
200-240V
22.5A
8 x IEC320 C13
2 x IEC320 C19
EBM
39Y8857
FC 5743
EBM
EBM
-
Plug Type
IEC 309 P+N+G
NEMA L6-30P
AUS/NZ 3112 32A
KSC 8305 30A
Country or Region
International
North America
Australia / New Zealand
South Korea
P a g e | 37
Load Segemnt 2
Load Segemnt 1
15A
Breaker
Amperage
C13
C13
C13
C13
C19
10A
10A
10A
10A
16A
C13
C13
C13
C13
C19
Outlet Type
15A
AC to DC
then
DC to AC
10A
10A
10A
10A
16A
Input Line
P a g e | 38
+3
2733
1950
1223
882
686
559
470
405
355
315
283
235
200
174
153
137
107
88
72
60
54
+4
3596
2566
1610
1162
904
737
620
534
468
416
374
311
265
230
203
181
142
117
100
85
75
P a g e | 39
Part Number
Feature Code
EBMs Supported
U Space
EPO Connection
Power Factor
UPS Type
Supported Country or
Region
Input
Line Cord
Voltage Range
Max Current
Phase / Frequency
Surge Energy Rating
Output
Watts
Nominal Voltage
Maximum Amperage
Receptacles
UPS6000 200/208V
5395-6AX
5395-RU4 (FC 6660)
1
4
Yes
0.9
Line Interactive
UPS6000 230V
5395-6KX
5395-RU4 (FC 6661)
1
4
Yes
0.9
Line Interactive
EBM
69Y1984
5395-RU4 (FC 5734)
3
-
World Wide
200/208V
Hardwired
155-255V for 200/208V
30A
1ph / 50 or 60Hz.
1300 joules
200/208V
5600W
208V
(Configurable)
28A
2 x NEMA L6-30R
4 x IEC 320 C19
230V
Hardwired
160V-286V for 230V
32A
1ph / 50 or 60Hz.
1300 joules
230V
5600W
220, 230, or 240V
(Configurable)
28A
4 x IEC 320 C19
6 x IEC 320 C13
EBM
EBM
-
Optional Accessories
Network Management Card (NMC)
P/N: 46M4110 FC: 6145
P a g e | 40
Optional EBM
Connector
2 NEMA L6-30R
(Load Segment 2)
Output Circuit
Breaker (20A)
Optional
NMC Bay
RS-232
Connector
USB
Input Terminal
Block w/ Cover
Output Circuit
Breaker (20A)
Ground
Screw
Outlet
Amperage
20A
20A
AC to DC
then
DC to AC
30A
30A
L6-30
L6-30
20A
20A
20A
20A
C19
C19
C19
C19
Input Line
Outlet Type
P a g e | 41
Optional EBM
Connector
Remote emergency
power-off port
Output Circuit
Breaker (20A)
Output Circuit
Breaker (15A)
Optional
NMC Bay
RS-232
Connector
USB
Input Terminal
Block w/ Cover
Ground
Screw
15A
Outlet
Amperage
20A
20A
AC to DC
then
DC to AC
10A
10A
10A
10A
10A
10A
C13
C13
C13
C13
C13
C13
20A
20A
20A
20A
C19
C19
C19
C19
Input Line
Outlet Type
P a g e | 42
%
25%
50%
75%
100%
Load (W)
1400
2800
4200
5600
Number of EBM
(P/N: 69Y1984 FC: 5734)
Internal
Batteries
+1
51 minutes
112 minutes
21 minutes
51 minutes
12 minutes
31 minutes
8 minutes
19 minutes
P a g e | 43
200V
208V
220V
230V
240V
Install a utility circuit breaker according to local electrical codes (see table below) for input wiring.
Uninterruptible
Terminal
power supply
Terminal wire
Tightening
1
Wire functions
position
wire function
size rating
torque
1
Input ground
2
5.26 - 16 mm
2.49 Nm (22
Input
2
L2 / Neutral In
(10-6 AWG)
inch-pounds)
3
L1 In
6000 VA, 200 V / 208 V models only: A 40 A 2-pole circuit breaker to provide short circuit and over current
protection.
6000 VA, 230 V models only: A 32 A (for Europe) or 40 A (for North America) 2-pole circuit breaker to provide
short circuit and over current protection.
(For Europe) The breaker meets the IEC/EN 60934 standard and has a contact air gap of at least 3 mm.
Notes Wire color code varies depending on location. Check with the local Authority Having Jurisdiction (AHJ)
for proper color code. AWG stands for American Wire Gauge
UPS7500/10000 Back
Output Pwr
Zone
1
N
O
C
O
M
Reset
N
C
+ G
N
1 NN O
2 DO
V
Probe
C
O
M
N
C
10/100Base-T
C
O
M
10/100
www.apcc.com
Test
TVSS
GND
UPS 10000
EBM Back
TVSS
GND
EBM Front
Model
Part Number
New T-M-F
Ordering System
EBMs Supported
EPO Connection
Power Factor
UPS Type
Input
Line Cord
Voltage
VA
Max Current
Phase / Frequency
Output
VA
Nominal voltage
Max Current
Receptacles
UPS7500XHV
21303RX
2130RU1-1079
UPS7500JHV
21303JX
UPS10000XHV
21304RX
2130RU1-1080
UPS10000JHV
21304JX
EBM
39Y8857
FC 5743
4
Yes
0.8
Double
Conversion
UPS7500XHV
Hard Wired
1
200-240V 1ph
2
380-415V 3ph
7500
1
38A 1ph
2
14A 3ph
1
1ph / 50 or 60Hz
2
3ph / 50 or 60Hz
UPS7500XHV
6000
200-240V 1ph
30A
4 x IEC320 C19
4
Yes
0.8
Double
Conversion
UPS7500JHV
Hard Wired
1
200V 1ph
4
Yes
0.8
Double
Conversion
UPS10000XHV
Hard Wired
1
200-240V 1ph
2
380-415V 3ph
10000
1
50A 1ph
2
18A 3ph
1
1ph / 50 or 60Hz
2
3ph / 50 or 60Hz
UPS10000XHV
8000
200-240V 1ph
40A
4 x IEC320 C19
4
Yes
0.8
Double
Conversion
UPS10000JHV
Hard Wired
1
200V 1ph
10000
1
50A 1ph
1ph / 60Hz.
UPS10000JHV
8000
200V 1ph
40A
4 x IEC320 C19
EBM
-
7500
1
38A 1ph
1ph / 60Hz.
UPS7500XHV
6000
200V 1ph
30A
4 x IEC320 C19
EBM
-
P a g e | 45
Zone
1
N
O
C
O
M
Reset
N
C
+ G
N
1 NN O
2 DO
V
Probe
C
O
M
N
C
10/100Base-T
C
O
M
10/100
AP9619 Network Management Card EM
TVSS
GND
www.apcc.com
Outlets
Input Block & Cover
Outlet Circuit Breakers
EBM Connection Block
20
16A
C19
16A
C19
16A
C19
16A
C19
20
Breaker
Amperage
Outlet Type
20
20
AC to DC
then
DC to AC
Input Line UPS7500 Input = 38A 200-240V
UPS10000 Input = 50A 200-240V
P a g e | 46
+0
360
249.6
189.6
153
126.6
108
93.6
82.8
73.8
69.6
55
47
41
36
32
24
19
17
13
10
7
5
4
+1
655.8
459
349.8
280.8
234.6
199.8
174
153.6
138
124.8
103.8
90
76.8
67.8
60
48
39
34
28
21
16
13
11
+2
1023.6
715.8
546.6
441
367.2
314.4
273.6
243
216.6
196.8
163.8
141
123
108.6
96.6
76.8
60
55
46
35
28
23
20
+4
Inter(hour
1789.8
Recharge
Hours
10
17
1254
960
772.8
645
552.6
481.8
426.6
382.8
346.8
291
249.6
217.8
193.8
174
136.8
112.8
99
81.6
63.6
52
44
37
P a g e | 47
Zone
1
N
O
C
O
M
Reset
N
C
+ G
N
1 NN O
2 DO
V
Probe
C
O
M
N
C
10/100Base-T
C
O
M
10/100
TVSS
GND
TVSS
GND
TVSS
GND
www.apcc.com
P a g e | 48
L1
L2
L3
L1
200V
208V
220V
230V
240V
L2
L3
380V
400V
415V
Install a utility circuit breaker according to local electrical codes (see table below) for input wiring.
Typical
Typical
System
Input Voltage
Nominal Current Full Load
Breaker Size Wire Size
2
220/230/240V 1ph
38A
50A
10mm
UPS7500
2
380/400/415V 3ph Y 14A per ph online, 38A on L1 in bypass
50A
10mm
2
220/230/240V 1ph
50A
63A
16mm
UPS10000
2
380/400/415V 3ph Y 18A per ph online, 50A on L1 in bypass
63A
16mm
1
1
L1
L2
L3
200V
to
240V
Line to Line
200V
208V
220V
230V
240V
Install a utility circuit breaker according to local electrical codes (see table below) for input wiring.
Nominal Current
Typical
Typical
System
Input Voltage
Full Load
Breaker Size
AWG
UPS7500
38A
50A
6
200 - 240V 1ph
(2P+G)
UPS10000
50A
60A
6
Notes Wire color code varies depending on location. Check with the local Authority Having Jurisdiction (AHJ)
for proper color code. AWG stands for American Wire Gauge
P a g e | 49
Female End
Male End
100/120V NEMA 5-15P (North America & Japan) UPS1500 RM & Tower
Detachable 4.3m, 15A/100-120V, C13 to NEMA 5-15P Line Cord
Used with:
5396-1AX UPS1000 Tower 120V (Line cord comes with UPS)
5396-1JX UPS1000 Tower 100V (Line cord comes with UPS)
5396-2AX UPS1500 Tower 120V (Line cord comes with UPS)
53951AX UPS1500 RM 100/120V (Line cord comes with UPS)
Female End
Male End
Female End
Male End
P a g e | 50
120V
SYS.
GR.
EQUIP.
GR.
W
G
NEMA L5-30
208V 120V
G
120V
EQUIP.
GR.
NEMA L6-20
P a g e | 51
CEE7-VII (Europe)
P/N: 39Y7917 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
P/N: 81Y2376 4.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
Used with:
5396-1KX UPS1000 Tower 230V
5396-2KX UPS1500 Tower 230V
2130R4X UPS1000THV
2130R6X UPS1500THV
Female End
Male End
DK2-5a (Denmark)
P/N: 39Y7918 2.8m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord
P/N: 81Y2382 4.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord
Used with:
5396-1KX UPS1000 Tower 230V
5396-2KX UPS1500 Tower 230V
Female End
2130R4X UPS1000THV
2130R6X UPS1500THV
Male End
Female End
2130R4X UPS1000THV
2130R6X UPS1500THV
Male End
P a g e | 52
SI 32 (Israel)
P/N: 39Y7920 2.8m, 10A/230V, C13 to SI 32 (Israel) Line Cord
P/N: 81Y2381 4.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord
Used with:
5396-1KX UPS1000 Tower 230V
5396-2KX UPS1500 Tower 230V
2130R4X UPS1000THV
2130R6X UPS1500THV
Female End
Male End
2130R4X UPS1000THV
2130R6X UPS1500THV
P/N: 40K9768 4.3m, 16A/230V, C19 to CEI 23-16 (Italy) Line Cord
Used with: 53953KX UPS3000 RM 230V
Female End
Male End
P a g e | 53
2130R4X UPS1000THV
2130R6X UPS1500THV
P/N: 40K9770 4.3m, 16A/230V, C19 to SABS 164 (South Africa) Line Cord
Used with: 53953KX UPS3000 RM 230V
Female End
Male End
BS 1363/A (UK)
P/N: 39Y7923 2.8m, 10A/230V, C13 to BS 1363/A (UK) Line Cord
P/N: 81Y2377 4.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord
Used with:
5396-1KX UPS1000 Tower 230V
5396-2KX UPS1500 Tower 230V
2130R4X UPS1000THV
2130R6X UPS1500THV
P/N: 40K9767 4.3m, 13A/230V, C19 to BS 1363/A w/13A fuse (UK) Line Cord
Used with: 53953KX UPS3000 RM 230V
Female End
Male End
P a g e | 54
2130R4X UPS1000THV
2130R6X UPS1500THV
P/N: 40K9773 4.3m, 15A/230V, C19 to AS/NZS 3112 (Aus/NZ) Line Cord
Used with: 53953KX UPS3000 RM 230V
Female End
Male End
2130R4X UPS1000THV
2130R6X UPS1500THV
P/N: 59Y2749 4.3m, 16A/220V, C19 to KSC 8305 (S. Korea) Line Cord
Used with: 53953KX UPS3000 RM 230V
Female End
Male End
P a g e | 55
IS6538 (India)
P/N: 39Y7927 2.8m, 10A/240V, C13 to IS6538 (India) Line Cord
P/N: 81Y2386 4.3m, 10A/240V, C13 to IS6538 (India) Line Cord
Used with:
5396-1KX UPS1000 Tower 230V
5396-2KX UPS1500 Tower 230V
2130R4X UPS1000THV
2130R6X UPS1500THV
Female End
Male End
GB 2099.1 (China)
P/N: 39Y7928 2.8m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
P/N: 81Y2378 4.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
Used with:
5396-1KX UPS1000 Tower 230V
5396-2KX UPS1500 Tower 230V
2130R4X UPS1000THV
2130R6X UPS1500THV
Female End
Male End
P a g e | 56
Female End
2130R4X UPS1000THV
2130R6X UPS1500THV
Male End
2130R4X UPS1000THV
2130R6X UPS1500THV
P/N: 40K9777 4.3m, 16A/220V, C19 to IRAM 2073 (Argentina) Line Cord
Used with: 53953KX UPS3000 RM 230V
Female End
L
Male End
L
Female Sleeve
N
G
Male Sleeve
L
G
P a g e | 57
Female End
Male End
Female End
Male End
P/N: 59Y2746 4.3m, 16A/125V, C19 to CNS 10917 125V Line Cord
Used with: 53952AX UPS2200 RM 100/120V
Female End
Male End
P a g e | 58
P/N: 59Y2747 4.3m, 15A/250V, C19 to CNS 10917 250V Line Cord
Used with: 53953KX UPS3000 RM 230V
Male End
Male Pin
L
220- 240V
220- 240V
N
L
L
G
EQUIP.
GR.
100-120V
EQUIP.
GR.
NEMA L6-30
P a g e | 59
Male Pin
L
230V
230V
N
G
EQUIP.
GR.
Female End
L
N
G
Male End
L
L
220V 220V
N
G
EQUIP.
GR.
P a g e | 60
Reference Material
IBM BladeCenter Chassis Label Rating
Chassis
BC E
BC E
BC H
BC HT
BC T
BC S
Power Supply
Wattage
2000W
2320W
2900W
3160W
1300W
950W / 1450W **
Power Supplies
Standard
2
2
2
2
2
2
Power Supplies
Max
4
4
4
4
4
4
100-127V
Rating
11.2A / Supply
200-240V Rating
12A / Supply
13.8A / Supply
37A / Connector *
16A / Supply
7.5A / Supply
8A / Supply
* - 37A per power connector (16A, 16A, 5A) redundant, 24A per power connector non-redundant
** - 950W is at 100-127V and 1450W is at 200-240V
100-127V
Rating /
Server
5.58A
3.9A
3.9A
3.9A
3.9A
5.58A
3.01A
4.54A
3.7A
4.54A
4.54A
3.5A
4.54A
3.9A
3.9A
3.9A
4.54A
3.9A
3.5A
200-240V
Rating /
Server
2.79A
1.95A
1.95A
1.95A
2.06A
2.79A
1.57A
2.27A
1.85A
2.27A
2.27A
1.75A
2.27A
1.95A
1.95A
1.95A
2.27A
1.95A
1.75A
P a g e | 61
Power
Supplies
Standard
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
Power
Supplies
Max
1
1
1
1
2
1
2
1
2
1
2
1
1
1
2
1
2
1
2
1
2
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
x3690 X5 (7148)
675W
1500W
775W
1300W
1440W
1440W
1975W
1300W
1
2
1
1
1
2
2
2
3
2
2
2
2
2
Server
x3100 (4348)
x3100 M3 (4253)
x3105 (4347)
x3200 (4362, 4363)
x3200 (4362, 4363)
x3200 M2 (4367, 4368)
x3200 M2 (4367, 4368)
x3200 M2 (9234)
x3200 M2 (9234)
x3200 M3 (7327, 7328)
x3200 M3 (7327, 7328)
x3250 (4364, 4365)
x3250 M2 (4190, 4194)
x3250 M3 (4251, 4252)
x3350 (4192, 4193)
x3400 (7973, 7974)
x3400 (7975, 7976)
x3400 M2 (7836, 7837)
x3400 M2 (7836, 7837)
x3400 M3 (7378, 7379)
x3400 M3 (7378, 7379
x3450 (7948)
x3455 (7984)
x3455 (7940, 7941)
x3500 (7977)
x3500 M2 (7839)
x3500 M2 (7839)
x3500 M3 (7380)
x3500 M3 (7380)
x3550 (7879)
x3550 M2 (7946)
x3550 M3 (7944)
x3650 (7979)
x3650 T (7980)
x3650 M2 (7838)
x3650 M2 (7947)
x3650 M3 (7945)
x3655 (7985)
x3690 X5 (7148)
P a g e | 62
100-127V Rating /
Server
4.5A
4.9A
4.5A
5.5A
5.5A
5.5A
5.5A
5.5A
5.5A
5.5A
5.5A
6A
4.5A
4.5A
4.1A
5A
6.5A
10A
10A
10A
10A
7A
6.1A
6.1A
6.5A
10A
10A
10A
10A
7A
7.8A
7.8A
9.7A
6A
7.8A
7.8A
7.8A
9.7A
7.8A
15.5A per server
7.8A per plug
17.6A
18.4A
15.75A
17.2A
17.2A
20A
15.75A
200-240V
Rating / Server
2.25A
2.4A
2.25A
2.75A
2.75A
2.75A
2.75A
2.75A
2.75A
2.75A
2.75A
3A
2.25A
2.25A
2A
2.5A
3.25A
5A
5A
5A
5A
3.5A
3.0A
3.0A
3.25A
5A
5A
5A
5A
3.5A
3.8A
3.8A
4.85A
3A
3.8A
3.8A
3.8A
4.85A
3.7A
7.4A per server
3.7A per plug
8.8A
9.2A
7.875A
8A
8A
10A
7.875A
Redundant
@
100-127V
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
No
Slot
Configuration
Power
Supply
Wattage
Power
Supplies
Standard
Power
Supplies
Max
2U Flex Chassis
(7831, 6385)
2 Planars
900W High
Efficiency
2U Flex Chassis
(7831, 6385)
1 Planar with
I/O Tray
900W High
Efficiency
2U Flex Chassis
(7381, 6385)
1 Planar with
Storage Tray
900W High
Efficiency
900W High
Efficiency
3U Storage Chassis
(7834, 6386)
P a g e | 63
Chassis
Rating
100V 8.62A
110V 7.71A
115V 7.35A
120V 7.00A
127V 6.63A
200V 4.19A
208V 3.98A
220V 3.81A
230V 3.61A
240V 3.46A
100V 5.90A
110V 5.28A
115V 5.01A
120V 4.83A
127V 4.61A
200V 2.93A
208V 2.83A
220V 2.68A
230V 2.57A
240V 2.47A
100V 5.54A
110V 4.89 A
115V 4.67A
120V 4.44A
127V 4.20A
200V 2.67A
208V 2.56A
220V 2.43A
230V 2.33A
240V 2.24A
100V 7.61A
110V 6.90A
115V 6.52A
120V 6.28A
127V 5.90A
200V 3.73A
208V 3.59A
220V 3.37A
230V 3.24A
240V 3.13A
Power
Supplies
Max
Dual 750W
Power Supply
1 Planar with
I/O Tray
Dual 750W
Power Supply
1 Planar with
Storage Tray
Dual 750W
Power Supply
Dual 750W
Power Supply
Slot
Configuration
Power Supply
Wattage
2U Flex
Chassis
(7831, 6385)
2 Planars
2U Flex
Chassis
(7831, 6385)
2U Flex
Chassis
(7381, 6385)
Chassis
3U Storage
Chassis
(7834, 6386)
Chassis
Rating
200V 3.90A
208V 3.80A
220V 3.53A
230V 3.38A
240V 3.22A
200V 2.37A
208V 2.27A
220V 2.15A
230V 2.05A
240V 1.97A
200V 2.43A
208V 2.32A
220V 2.19A
230V 2.11A
240V 1.99A
200V 2.89A
208V 2.76A
220V 2.61A
230V 2.51A
240V 2.39A
Power
Supply
Wattage
310W
400W
430W
530W
514W
670W
370W
775W
350W
332W
411W
585W
625W
1300W
1200W
1200W
1300W
Power
Supplies
Standard
1
1
1
1
1
1
2
2
1
1
1
1
1
1
2
4
2
Power
Supplies
Max
1
1
2
1
2
2
4
3
1
1
1
2
2
2
2
4
2
P a g e | 64
100-127V
Rating /
Server
4.5A
5.5A
5.5A
7A
7A
8.93A
10A
18.4
4.3A
4A
3.5A
5.5A
8.3A
15.75A
9.5A
19A
15.75A
200-240V
Rating /
Server
2.25A
2.75A
2.75A
3.5A
3.5A
4.465A
5A
9.2A
2.15A
2A
1.75A
2.75A
4.15A
7.875A
4.75A
9.5A
7.875A
Redundant
@ 100-127V
Yes
Yes
Yes
Yes
No
Yes
Yes
No
No
No
No
j im S
|S|
jQ
q
P
Re S
The x axis is the real part of the apparent power and the y axis represents the imaginary part of S. The apparent
power by definition is the vector sum of the real and reactive power.
Translating this to terms that most are familiar with, think of a freshly poured glass of beer. When the glass is full
it is considered collectively as a beer and is equivalent to apparent power S. This collective beer is made up of
liquid beer (real power P) and foam (reactive power Q). The liquid beer (real power P) is what is desired, but you
must pay for the foam (reactive power Q) as well. The better the bartender (power supply vendor) the more liquid
beer (real power P) and less foam (reactive power Q) you get.
Back to the math, we introduce the concept of power factor. Power factor is a dimensionless number between 0
and 1 and can be calculated through the following relationship.
pf =
Real Power
Apparent Power
P
S
Power factor, more importantly power factor correction, is important because loads with low power factor require
higher current than loads with a power factor closer to 1. When planning circuits, PDUs, and UPS systems, a
higher power factor is desired to minimize the current draw on the infrastructure and maximize power distribution
efficiency.
Getting into a little more detail, pf=1 means that all energy supplied in the circuit is consumed by the load, which is
purely resistive. As the power factor decreases (pf<1) the circuit is said to have become more reactive. A
reactive circuit stores energy in the load for part of the AC cycle which is then returned to the source later in the
cycle. At the opposite end, pf=0 means that the energy supplied at one point in the cycle is stored in the load and
returned to the source at another point in the cycle.
Todays IT equipment, for the most part, employs some type of power factor correction. This means that the
switching power supply units in the IT equipment are designed to appear as resistive devices to the electrical
P a g e | 65
P a g e | 66
60
20 30 32
60 63 100
100V - 130V
Orange
125V/250V
Blue
200V - 250V
Gray
277V
Red
380V - 480V
Black
500V - 690V
Environmental Rating
P - Plug
C - Connector
R - Receptacle
B - Inlet
Clock
Position
Of Female
Sleeve
W-WATERTIGHT
(SCREW CAP &
LOCKING RING)
460C9W IP-67
o
Voltage Rating
Polarization
Example
o
Color
Yellow
Device Type
Female Sleeve
Male Pin
L3
L3
L2
L2
L1
L1
3 Pins = 1ph
4 Pins = 3ph
5 Pins = 3ph Y
P/N HBL460C9W
First Number
Second Number
Ingress Protection
0 No Protection
0 No Protection
1 50mm Diameter
1 Vertically Dripping
2 Dripping At 15 Of Tilt
3 Spraying Up To 60 Of Tilt
4 Splashing
5 Jetting
6 Power Jetting
7 Temporary Immersion
8 Continuous Immersion
IP
2 12.5mm Diameter
First Number: degree of protection
for persons against access of
hazardous parts inside the enclosure
and/or against foreign objects.
Second Number: degree of
protection of equipment inside
enclosures against damage from
ingress of water.
3 2.5mm Diameter
4 1.0mm Diameter
5 Dust-Protected
6 Dust-Tight
P a g e | 67
Connector
AMP Rating
C5 Female
C6 Male
Use
Laptop Power Supplies And Other Portable Power
Supplies
2.5A
C7 Female
C8 Male
C13 Female
C14 Male
2.5A
10A
C15 Female
C16 Male
10A
C19 Female
C20 Male
16A
IA
IL = 60A
= 3 x 208 x 60 x 1
IAC
208V
PTotal = 3 x ELL x IL x pf
IBA
IC
208V
ICB
= 21616W
208V
= 21616W x 0.8
IB
= 17293W
IF = IAC = IBA = ICB =
IL
60
=
= 34.64A
3
3
Variables Defined
IF = Phase Current
IL = Line Current
ELL = Line to Line Voltage
pf = Power Factor
P = Power In Watts
P a g e | 68
IA
A
EF=220V
EL
3
380
3
= 220V
EL=380V
B
IF
EL=380V
IB
EL=380V
IC
P a g e | 69
IBM UPS5000
Base Unit & EBM
http://www-947.ibm.com/systems/support/supportsite.wss/docdisplay?lndocid=MIGR-5082280&brandind=5000008
EBM
http://www-947.ibm.com/systems/support/supportsite.wss/docdisplay?lndocid=MIGR-58642&brandind=5000019
P a g e | 70
Helpful Links
IBMs System x UPS Web Site (this document)
http://www-03.ibm.com/systems/x/hardware/options/ups.html
IBM System x PDU Guide North American
http://www-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/WP101526
IBM System x PDU Guide International
http://www-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/WP101615
IBM System x PDU Guide North American
http://www-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/WP101526
IBM System x and BladeCenter Power Configurator
http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html
IBMs System x UPS Web Site
http://www-03.ibm.com/systems/x/hardware/options/ups.html
Hubbell - Twist Lock Plug/Outlet Catalog (Includes NEMA Outlets)
http://www.hubbellcatalog.com/wiring/catalogpages/section-b.pdf
Hubbell - Pin & Sleeve Plug/Outlet Catalog (Includes IEC309 Outlets)
http://www.hubbellcatalog.com/wiring/catalogpages/section-E.pdf
IBM, the IBM Logo, BladeCenter, iDataPlex, DPI, IntelliStation and System x are registered trademarks or
trademarks of International Business Machines Corporation in the United States, other countries or both.
Other company, product or service names may be trademarks or service marks of others.
P a g e | 71