Sie sind auf Seite 1von 14

Warning

PCR0720

Daikin Industries, Ltd.s products are manufactured for export to numerous countries throughout the
world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a
particular country. Prior to purchase, please therefore confirm with your local authorised importer,
distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for
use, in the region where the product will be used. This statement does not purport to exclude, restrict
or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.

The Comfort and Luxury You D eserve

Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

JMI-0107

JQA-1452

About ISO 9001


ISO 9001 is a plant certification system
defined by the International Organization for
Standardization (ISO) relating to quality
assurance. ISO 9001 certification covers
quality assurance aspects related to the
design, development, manufacture,
installation, and supplementary service of
products manufactured at the plant.

About ISO 14001


ISO 14001 is the standard defined by the
International Organization for Standardization
(ISO) relating to environmental management
systems. Our group has been acknowledged
by an internationally accredited compliance
organisation as having an appropriate
programme of environmental protection
procedures and activities to meet the
requirements of ISO 14001.

Dealer
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global/
c All rights reserved
Printed in Japan 12/06/003 DN

Specifications, designs and other content appearing in this brochure are current as of December 2006 but subject to change without notice.

Printed on 100% recycled paper with soy ink.

Multi-Split Type Air Conditioners D series


With DC Inverter and Swing Compressor
Cooling Only & Heat Pump [50/60 Hz]

Air condition your entire home


with a single outdoor unit.
Contents

If you would like your conditioners


to match your personal d
c or
If you wish to make more effective use
of the space on your balcony

If you want your family to be


comfortable

Concepts

Main features

Product lineup

Functions

15

Specifications

21

Options

22

Capacity tables

23

Super Multi N X is the knowledgeable choice.


The D aikin Super Multi N X lets you build a highly efficient multi room air
conditioning system by connecting up to four indoor units to a single outdoor unit.
The series includes a wide variety of indoor units, so it is easy to select a model that
blends in unobtrusively and allows you to create a d
c or that matches your personality.
A single compact outdoor unit allows you to make more efficient use of available
space in the installation location, such as a balcony. The individual indoor units in
different roomsthe living room, study, and bedrooms, for examplecan be controlled
independently to match your family s lifestyle. Super Multi N X makes your home
1

Concepts

Concepts

Key concepts for Super Multi N X


Enjoy the comfort and luxury of your dreams.

I n1969, Daikindevelopedthefirst multi roomair conditioningsysteminJapanthat


neededjust oneoutdoor unit. Over theensuing35years, Daikinhas built anenviable
reputationwith theconstant progress of its technology. Super Multi N X requires only a
singleoutdoor unit tomaintainpleasant comfort inuptofour rooms. Whereoutdoor unit
installationspaceis limited, it is theideal choice. A ir conditioner settings for each room
canbecontrolledindividually tosuit thepreferenceof each person. Whileoptimising
personal comfort, Super Multi N X uses DC inverter technology toreduceenergy waste.
2MKD series

3MK(X)D series
New

Design

New

Design

The D C motor, swing compressor and other


advanced technologies make for energyefficient operation that achieves high CO Ps.

The quiet operation mode helps create a more


pleasant living environment. D C inverter
power control provides comfortable
Up to 2 indoor units can be connected.

Up to 3 indoor units can be connected.

4MK(X)D series
New

Design

Up to 4 indoor units can be connected.

The wide range of indoor unit options


provides ample choice. A single compact
outdoor unit reduces installation space
requirements, while long maximum piping
lengths provide flexibility for connections.

The individual indoor units in different rooms


can be controlled independently. The priorityroom setting function lets you specify a room
to receive preference in air conditioning

Connect 4 indoor units to a single outdoor unit

Main features

ntelligent
technologies

Main features

High energy efficiency through advanced

Convenient features to realise your

technologies delivers high COP.

ideal environment

deal
environment

Quiet operation

High energy efficiency for high COP

Indoor unit
COP during cooling operation (4MXD80BVMA)

3.32

COP during heating operation (4MXD80BVMA)

A quiet indoor unit is important for your personal comfort. SUPER


MULTI NX offers the quiet sound level of 25 dB during Indoor Unit
Quiet Operation of the FTKD25D.

4.00

25 dB

Note: Capacity may decrease when quiet functions are selected.

* During rated capacity operation of 4 indoor units


(2.5 + 2.5 + 2.5 + 6.0 kW class).

25 dB is so quiet you can even hear whispers

Rustling of leaves

What is COP?
COP =

An air conditioner's COP (coefficient of performance) indicates how


efficiently it uses energy. A high COP means high energy efficiency.

Capacity (kW)
Power consumption (kW)

20

30

Library

40

Ticking of a wall clock

50

(dB)

Typical office

Outdoor unit

Daikin energy-saving technologies

The reluctance DC motor is much more


efficient than conventional AC and DC
motors. Its advanced design has
improved low-capacity
operation by more
than 20%.

Motor efficiency (%)

1 Reluctance DC motor

Neodymium magnet

Reluctance DC Motor

90

80

Conventional
DC motor

More than 20%

70

The reluctance DC motor employs


neodymium magnets. These magnets
are approximately 10 times stronger
than ferrite magnets.

A quiet outdoor unit is essential for your comfort and peace in your neighbourhood. SUPER MULTI NX
achieves a quiet sound level of 43 dB during Outdoor Unit Quiet Operation or Night Quiet Mode of the
2/3MKD58D. The minimum outdoor unit sound level is 39 dB.*
* Achievable when:
1. A single 2.5 kW class indoor unit is operating.
2. Indoor Unit Quiet Operation is selected for all indoor units in operation.
3. Outdoor Unit Quiet Operation is selected.
Note: Capacity may decrease when quiet functions are selected.

AC motor
60

50
0

30

60

90

120

Rotational speed (rps)


Small load
Low capacity

Large load
High capacity

Neodymium magnet

2 Swing compressor
The swing compressor decreases friction
and vibration and also prevents the
leakage of refrigerant gas
during compression.
This gives much quieter
and more efficient
operation.

Swing bush

Comfortable temperature control

Ferrite magnet

DC inverter power control uses its


full capacity at startup to cool/warm
quickly. As soon as the set
temperature is reached, it carefully
adjusts current frequency to
prevent temperature fluctuation and
energy loss.

Refrigerant gas

Non-inverter type
Not cool

DC inverter type
Set temp.

During cooling operation


Time

Too cool

Integral piston of blade and roller

Energy efficiency is increased by reducing


operational friction and refrigerant gas leakage.

Starts

DC inverter power control gives you greater comfort

Wide operation range


Power
factor

Converter
efficiency

Inverter
efficiency

POWER

Power supply

3 PAM control
Pulse Amplitude Modulation (PAM) control
reduces energy loss by controlling the amount
of switching on/off of the converter.

Temp.

Even during a cold season, a crowded party or a sudden change in the


indoor temperature can leave a room overheated. With SUPER MULTI NX,
cooling operation is possible even during lower outdoor temperatures.
Note: This information is available for heat pump type.

Heat pump type


50
40
30
Outdoor
20
temp.
10
0

Loss

Loss

Cooling

46

CDB

Heating

15.5
CWB

-10
-20

Main features

Main features

Wide array of choices to match


your interior

nterior &
exterior
flexibility

Individual control for each room to match


your familys lifestyle

Preferential air conditioning

Stylish indoor units for elegant interiors

ndividual
control

Initial setting required during installation

Priority-Room Setting delivers priority capacity to a prioritised room when using multi-split air conditioners.
After a priority room is selected, it receives preferential air-conditioning plus priority control over the 3 functions below.

Priority setting with Inverter Powerful Operation


When Inverter Powerful Operation is selected in the priority room, the indoor unit capacity in the priority room is
increased by shifting capacity from units in other rooms. After 20 minutes, all units automatically return to their
original settings.
Note: Capacity in other rooms may decrease slightly.

Power Up!

Room
A
Room
B

Living
room

The stylish flat panel design of the wall-mounted type provides an excellent match
for the most refined of interiors.

Only 240 mm is required above the ceiling for


installation.

Compact outdoor units for a less obtrusive exterior look

Priority
room

Room
A
Room
B

Living
room

Priority
room

Room
C

Room
C

Priority setting with operation mode


The operation mode (cooling/heating) of the indoor unit in the priority room is given preference. When the
operation modes of the units in other rooms are different from the unit in the priority room, the units in the other
rooms wait on standby.

The system requires only a single


outdoor unit. The compact design
provides installation flexibility and
takes up less space, for a less
obtrusive exterior look.

Note: Operation mode can not be changed from other rooms.

3
Needs just one outdoor unit
keep your home exterior beautiful!

Priority setting with Outdoor Unit Quiet Operation


Priority-Room Setting also allows Outdoor Unit Quiet Operation to be selected by one command* from the
priority room.
* If Priority-Room Setting has not been set, the Outdoor Unit Quiet Operation button must be pushed on the
wireless remote controller of all indoor units operating at that time.

Long piping lengths for installation flexibility

Convenient remote controllers

The ample maximum piping length of 70 m permits


more freedom in the placement of air conditioner units
and facilitates the optimisation of interior space.

A variety of convenient controller systems permit individual control of


settings such as temperature, airflow volume, and operation duration.

2MKD58 3MKD58 3MKD75 4MKD75 4MKD100


Model name
Max.
piping
length

Total
Between rooms

3MXD68

35 m

45 m

60 m

4MXD80
70 m

25 m

Wireless remote controller

5-room centralised controller


(option)

Central remote controller


(option)

Unified on/off controller


(option)

Product lineup

Product lineup

A wide range of models to choose from that deliver excellent comfort and
convenience

An array of indoor unit models with innovative and attractive designs make
it easy to find the ideal match for each room in your home.

Outdoor units
Model

Model name

Capacity class

Max. piping length

Max. height difference

2MKD58DVM

5.8 kW

35 m

15 m

3MKD58DVM

5.8 kW

45 m

15 m

3MKD75DVM

7.5 kW

60 m

15 m

Heat pump

3MXD68BVMA

6.8 kW

45 m

15 m

Cooling only

4MKD75DVM

7.5 kW

60 m

15 m

Connectable to up to 2 indoor units


Cooling only

Connectable to up to 3 indoor units


Cooling only

Connectable to up to 4 indoor units

Wall-mounted type
Heat pump

4MXD80BVMA

8.0 kW

70 m

15 m

Cooling only

4MKD100DVM

10 kW

70 m

15 m

An attractive match for large rooms with refined interiors is provided


by the stylish flat panel design.

Indoor units
Model

Capacity class

2.5 kW

3.5 kW

5.0 kW

6.0 kW

7.1 kW

Cooling only

FTKD25DVM

FTKD35DVM

Heat pump

FTXE25BVMA

FTXE35BVMA

Cooling only

FTKD50FVM

FTKD60FVM

FTKD71FVM

Heat pump

FTXD50FVM

FTXD60FVM

FTXD71FVM

Wall-mounted type

New

Design

Duct-connected type

700 mm width

900/1,100 mm width

Floor/ceiling-suspended dual type

Cooling only

CDKD25EAVM

CDKD35EAVM

Heat pump

CDXD25EAVMA

CDXD35EAVMA

Cooling only

CDKD25CVM

CDKD35CVM

CDKD50CVM

CDKD60CVM

Heat pump

CDXD25CVMA

CDXD35CVMA

CDXD50CVMA

CDXD60CVMA

Cooling only

FLK25AVMA

FLK35AVMA

FLK50AVMA

FLK60AVMA

Heat pump

FLX25AVMA

FLX35AVMA

FLX50AVMA

FLX60AVMA

5.0 kW

6.0 kW

Duct-connected type

Fits in shallow ceiling recesses only 240 mm deep thanks to the new
slim and compact design.

Possible combinations for indoor and outdoor units


Capacity class
Model
Cooling only type
2MKD58D
3MKD58D
3MKD75D
4MKD75D
4MKD100D
Heat pump type
3MXD68B
4MXD80B

2.0 kW

2.5 kW

3.5 kW

7.1 kW

Floor/ceiling-suspended dual type

Chose either ceiling-suspended or floor-level installation for this


attractive model with a beautiful, rounded design.

10

Product lineup

Product lineup

W all-Mounted Type Indoor U nits

D uct-Connected Type Indoor U nits

GOOD DESIGN
AWARD 2004
IN JAPAN

Cooling only

2.5 kW class

3.5 kW class

FTKD25DVM

FTKD35DVM

2.5 kW class 3.5 kW class 5.0 kW class 6.0 kW class


700 mm width type
Cooling
only
Heat
pump

CDKD25EAVM CDKD35EAVM
CDXD25EAVMA CDXD35EAVMA
900/1,100 mm width type

Cooling
only
Heat
pump

Heat pump

2.5 kW class

3.5 kW class

FTXE25BVMA

FTXE35BVMA

CDKD25CVM

CDKD35CVM

CDKD50CVM

CDKD60CVM

CDXD25CVMA CDXD35CVMA CDXD50CVMA CDXD60CVMA

Slim and compact design


Models in the CDK(X)D-EA series are only 700 mm in width
and 21 kg in weight, so are easily installed in limited spaces.
Just 200 mm in height, all models can be installed in rooms
with as little as 240 mm depth between the drop ceiling and
ceiling slab, making them ideal for even shallow ceilings.

More
compact

New

Design

Clean air

5.0 kW class

6.0 kW class

7.1 kW class

Cooling only

FTKD50FVM

FTKD60FVM

FTKD71FVM

Heat pump

FTXD50FVM

FTXD60FVM

FTXD71FVM

Uses a Titanium Apatite Photocatalytic Air-Purifying


Filter. Titanium apatite is a photocatalytic material
with high adsorption power. It effectively adsorbs
and removes bacteria and viruses along with mould
and odours. This filter is available for
FTK(X)D50/60/71F.

CDK(X)D-EA
Air discharge
duct*

Only 700 mm

200 mm
240 mm

AIR
Chamber

New

Function
Titanium Apatite
Photocatalytic
Air-purifying Filter

Wall-mounted type indoor units achieve quiet sound


levels of 25 dB during Indoor Unit Quiet Operation.
(H/L/SL)

FTKD25D
37/28/25 dB
11

FTKD35D
39/29/26 dB

Air filter*

Air discharge
grille*

Signal receiver wire


Length = 1,900 mm

Air filter
Catches dust

Quiet operation

Suspension bolt*

Easy cleaning
Flat panel can be cleaned
with just a single pass of a
cloth across its smooth
surface.

Signals from the wireless remote controller


are transmitted to the signal receiver.

CDK(X)D25EA CDK(X)D35EA CDK(X)D25C CDK(X)D35C


Dimensions (H x W x D)
200 x 700 x 620 mm 200 x 900 x 620 mm
Weight
21 kg
25 kg
8.7 m3/min
Airflow rate (H)
9.5 m3/min 10 m3/min
30 Pa
40 Pa
External static pressure

Quiet operation
Quiet operation sound level of only 29 dB is
achieved for 2.5 and 3.5 kW class models.

Air suction
grille*
Signal
receiver

AIR

Option

Suction grille (KDGF19A45)

* Locally obtained parts

Notes:
1. To prevent an increase in operation noise, avoid installing the air suction
grille directly below the suction chamber.
2. Grilles, piping connections, ducts, and installation parts should be
obtained locally.
Duct-connected types do not have drain-up pumps.
3. The signal receiver unit must be located near the air suction inlet,
because the unit includes a sensor that detects room temperature.

12

Product lineup

Functions

Floor/Ceiling-Suspended Dual Type Indoor U nits


Indoor units

Models
Wall-mounted type

Comfortable Airflow

Functions

FTKD25/35D

FTXE25/35B

Duct-connected type

FTK(X)D50/60/71F

CDK(X)D25/35EA
CDK(X)D25/35/50/60C

Outdoor units
Floor/ceiling-suspended
dual type

FLK(X)25/35/50/60A

Power-Airflow
Dual Flaps
Wide-Angle Louvres
Vertical Auto-Swing
(up and down)
Horizontal Auto-Swing
(left and right)
3-D Airflow
Indoor Unit Quiet
Operation
Outdoor Unit Quiet
Operation

Cooling
only

FLK25AVMA FLK35AVMA FLK50AVMA FLK60AVMA

Heat
pump

FLX25AVMA FLX35AVMA FLX50AVMA FLX60AVMA

Comfort Control

2.5 kW class 3.5 kW class 5.0 kW class 6.0 kW class

Night Quiet Mode


Intelligent Eye
Automatic Operation
(Heat pump type only)

Programme Dry
Function
Auto Fan Speed

Two-way installation
Ceiling-Suspended Installation

Lifestyle Convenience

The rounded design of these slim and lightweight units


makes them the perfect choice for rooms without false
ceilings. Ceiling-suspended installation frees up floor and
wall space, and floor-level installation is possible without
loss of warm air.

Comfortable airflow

Inverter Powerful
Operation

Econo Mode
Home Leave
Operation
Indoor Unit On/Off
Switch
Priority-Room Setting

Cleanliness

Vertical Auto-Swing and Wide-Angle Louvres realise a


comfortable airflow spreading throughout a large room, airconditioning the whole room evenly.

Titanium Apatite
Photocatalytic
Air-Purifying Filter
Photocatalytic
Deodorising Filter

New

Air-Purifying Filter
Mould-Proof Air Filter

Mould-Proof
Operation

Timers

Wipe-Clean Flat Panel

Quiet operation

Worry Free

The FLK25A achieves the quiet sound level of


28 dB. Indoor Unit Quiet Operation decreases the
operation sound by 2 or 3 dB from the low setting
fan speed.

(H/L/SL)

FLK25A

FLK35A

FLK50A

FLK60A

37/31/28 dB

38/32/29 dB

47/39/36 dB

48/41/38 dB

13

Floor-Level Installation

24-Hour On/Off Timer


Night Set Mode
Auto-Restart after
Power Failure
Self-Diagnosis with
Digital Display
Anticorrosion Treatment of
Outdoor Heat Exchanger Fins

14

Functions

Functions

Energy savings plus quick return to favourite comfort setting levels


Intelligent Eye with its infrared sensor
automatically controls air conditioner operation
according to human movement in a room. When
there is no movement, it adjusts the temperature
by 2C for energy savings of up to 20% for cooling
operation and 30% for heating operation. Intelligent Eye is
available for all wall-mounted models.

Home Leave Operation prevents large rises or falls


in the indoor temperature by continuing operation*
while you are sleeping or out of your home. This
means that an air-conditioned welcome awaits
when you wake or return. It also means that the indoor
temperature can quickly return to your favourite comfort
setting.

Uniform cooling/heating of the whole living room


Inverter Powerful Operation boosts cooling/heating
performance for a 20-minute period. This is
convenient both when you first turn on your air
conditioner and when you want to quickly change
the temperature during operation.

Vertical Auto-Swing automatically


moves the flaps up and down and
Horizontal Auto-Swing
automatically moves the louvres
to the left and right. 3-D Airflow combines Vertical and
Horizontal Auto-Swing to circulate air to every part of
a room for uniform cooling/heating of even large spaces.

* Home Leave Operation can be selected for any temperature from 18 to


32C for cooling operation and 10 to 30C for heating operation.

During cooling operation, 23C for the room temperature setting,


and 28C for the home leave setting.

23C

Power-Airflow Dual Flaps and Wide-Angle


Louvres work in tandem to precisely control
both vertical and horizontal airflow for even
distribution of air.

When you are in the room

Start Home Leave Operation simply by


pushing its button on the remote controller.

One push!!

A uniform temperature is
achieved throughout the
entire room.

Power-Airflow Dual Flaps

28C

The unit can be conveniently


started manually in the event
the wireless remote controller
is misplaced or the wireless
remote controller batteries are not
charged.

When you go out

Econo Mode
Econo Mode is a function that reduces the maximum
running current and the maximum power consumption of
the outdoor unit to the rated values. This mode is useful for
preventing circuit breakers from being overloaded by the
use of multiple air conditioners and other electrical
devices. The function is easily activated from the remote
controller by pushing the ECONO button. Econo Mode is
available for the FTKD25/35D.

When you are out of your home, your air conditioner prevents large rises
in the indoor temperature by continuing to operate using Home Leave
Operation settings.

Cooling: the flaps flatten out during


operation so that cool air slides off
to reach the farthest corners of the
room.

Heating: the flaps descend to blow


warm air directly down to the floor to
quickly warm the whole room.

+1C
+0.5C
Set temp. before
Off timer begins
to operate

Running current and


power consumption
Normal
operation

Pressing the Off timer button automatically selects


the Night Set Mode. This function prevents any
sudden change in room temperature by gently
raising/lowering the temperature before the air
conditioner stops, so you can sleep comfortably.

Wide-Angle Louvres

23C

From a corner
to the centre

Maximum

Maximum during
normal operation

Cooling

2C
60
Off timer turns on

Rated

Maximum during
Econo Mode
Econo
Mode

From start up until set


temperature is reached

Push again!!

The louvres can be


adjusted by hand for the
FTKD25/35D, FTXE25/50B
and FLK(X)25/35/50/60A.
The louvres can be
adjusted with the wireless
remote controller for the
FTK(X)D50/60/71F.

Time

This diagram is a representation for illustrative purposes only.


Maximum capacity decreases during Econo Mode, requiring
more time to reach the set temperature.

15

When you return, you will be greeted by an


air-conditioned room. Just push the HOME
LEAVE button again to return to your
previous settings.

Indoor Unit On/Off Switch

30

Heating
Time
Unit: minutes
Off timer stops air conditioner

Cooling operation: Room temperature is raised by 0.5C


after 60 minutes, while minimum outdoor unit sound levels
are maintained. If the outdoor temperature is below 27C,
room temperature is raised by a further 0.5C after 90
minutes except for FTKD25/35D.
Heating operation: Room temperature is lowered by 2C
after 60 minutes.

Entirely covers
a spacious room

Refer to page 14 to check the functions offered by individual models.

16

Functions

Functions

Clean air with less dust or odours


SUPER MULTI NX indoor units offer a range of features,
including advanced photocatalytic air-purifying filters, to help
keep indoor air clean. As well as decomposing unpleasant
odours, these advanced filters are able to remove bacteria
and viruses.

Easy-to-use wireless remote controller


Air-Purifying Filter
The filter removes bacteria and viruses, and
impurities such as dust, pollen and cigarette
smoke from the air. Its removal rate for bacteria
and viruses has been measured and verified by
the Japan Food Research Laboratories.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No.298051308-001
Virus Removal Test
Testing method: washout method
Result certificate: No.298051308-002
Testing organisation: Japan Food Research Laboratories

Air filter
Catches dust

New

Function
Titanium Apatite
Photocatalytic
Air-purifying Filter

FTK(X)D50/60/71F

Titanium Apatite Photocatalytic Air-Purifying Filter


Titanium apatite is a photocatalytic material with
high adsorption power. Besides mould and odours,
titanium apatite also effectively adsorbs and
decomposes bacteria and viruses across its entire
surface. The photocatalyst is activated simply by
exposure to natural light. This filter is installed in all
wall-mounted units.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 012553-1 and 012553-2
Testing organisation: Japan Spinners Inspecting Foundation

FTKD/25/35D

Vertical Auto-Swing
(up and down)
Selects fan speed and
Indoor Unit Quiet Operation
Selects mode: cooling,
dry, fan-only operation
Outdoor Unit Quiet Operation

Econo Mode
Sets room temperature
On/Off Switch
Inverter Powerful Operation

Mould-Proof Operation
Intelligent Eye
FTK(X)D50/60/71F FTKD25/35D, FTXE25/35B and FLK(X)25/35/50/60A
Filter type
Titanium apatite
Photocatalytic
Air-purifying
photocatalytic
deodorising
filter
air-purifying filter
filter
Maintenance Soak in water
Unnecessary
Expose to sunlight
containing detergent for 6 hours once
once every 6 months every 6 months
Replacement 3 years
Unnecessary
3 months
Number
2 pieces
1 piece
1 piece

Cancels On/Off Timer


24-Hour On Timer
24-Hour Off Timer
and Night Set Mode
Sets timer
Displays time

Mould-Proof Operation

FTKD25/35D, FTXE25/35B and FLK(X)25/35/50/60A

Photocatalytic Deodorising Filter


This filter decomposes odours and even removes
bacteria and viruses. This power is maintained
simply by exposing the filter to sunlight once every
6 months.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 298081197-003
Virus Removal Test
Testing method: washout method
Result certificate: No. 298081197-004
Testing organisation: Japan Food Research Laboratories

When cooling or dry operation is stopped, fan-only


operation runs automatically for one hour. This
airflow dries the inside of the indoor unit to reduce
the generation of mould and the odours caused by
mould.

FTK(X)D50/60/71F

Vertical Auto-Swing
(up and down)
Selects fan speed and
Indoor Unit Quiet Operation
Selects mode: automatic, cooling,
heating, dry, fan-only operation
Outdoor Unit Quiet Operation

Home Leave Operation


Sets room temperature
On/Off Switch
Inverter Powerful Operation

Intelligent Eye
Horizontal Auto-Swing
(left and right)
Cancels On/Off Timer
24-Hour On Timer
24-Hour Off Timer
and Night Set Mode
Sets timer
Displays time

Refer to page 14 to check the functions offered by individual models.

17

18

Functions

Comfortable Airflow

Functions

Automatic Operation
This function automatically selects cooling or heating
operation mode based on the room temperature at startup.

Power-Airflow Dual Flaps


Power-Airflow Dual Flaps can flatten out during cooling
operation to deliver cool air to the corners of
a room. The flaps can direct warm air straight down to
the floor during heating operation.

Programme Dry Function


This function automatically reduces the level of humidity
while maintaining the preset room temperature.

See page 16

Wide-Angle Louvres
Smoothly curved Wide-Angle Louvres provide wide
airflow coverage for effective cooling/heating no matter
where the indoor unit is placed in a room.

Auto Fan Speed


The microprocessor automatically controls fan speed to
adjust the room temperature to the set temperature.

Vertical Auto-Swing automatically moves the flaps up and


down to provide an even distribution of air throughout a room.
See page 16

Horizontal Auto-Swing (left and right)


Horizontal Auto-Swing automatically moves the louvres
to the left and right to cover a room with cool/warm air.

Lifestyle Convenience
Inverter Powerful Operation
This function is convenient for boosting cooling/heating
performance for a 20-minute period both when you first
turn on your air conditioner and want to quickly change
the room temperature.
See page 16

See page 16

3-D Airflow
This function combines Vertical and Horizontal
Auto-Swing to circulate a cloud of cool/warm air right
to the corners of even large spaces.
See page 16

Econo Mode
Econo Mode reduces the maximum running current and
the maximum power consumption of the outdoor unit to
the rated values. This is useful when using multiple air
conditioners and other electrical devices at the same
time.
See page 15

Comfort Control
Indoor Unit Quiet Operation
Indoor unit operating sound levels are decreased by 2 or
3 dB from the low setting fan speed using the wireless
remote controller.
See page 6

Outdoor Unit Quiet Operation


Outdoor unit operating sound levels are decreased by 3 dB
from the rated operation sound using the wireless remote
controller.
See page 6

Night Quiet Mode


Outdoor unit operating sound levels are automatically
decreased by 3 dB from the rated operation sound when
the outdoor temperature has dropped by 6C from the
maximum temperature recorded during the daytime.
Initial setting is required during installation.

Intelligent Eye
Intelligent Eye with its infrared sensor automatically
controls air conditioner operation according to human
movement in a room. When there is no movement, it
adjusts the temperature by 2C for energy savings of
up to 20% for cooling operation and 30% for heating
operation.

Worry Free

Titanium Apatite Photocatalytic


Air-Purifying Filter

Auto-Restart After Power Failure


The air conditioner memorises the settings for mode,
airflow, temperature, etc., and automatically returns to
them when power is restored after a power failure.

This filter combines the Air-Purifying Filter and


Titanium Apatite Photocatalytic Deodorising Filter
in a single highly effective unit. The filter traps
microscopic particles, decomposes odours and
even removes bacteria and viruses. It lasts for 3
years without replacement if washed about once
every 6 months.

Self-Diagnosis with Digital Display


Malfunction codes for each indoor unit are shown on the
digital display panel of the wireless remote controller for
fast and easy maintenance.

Anticorrosion Treatment of Outdoor Heat Exchanger Fins

See page 17

See page 16

Vertical Auto-Swing (up and down)

Cleanliness

Home Leave Operation


Home Leave Operation continues operation to prevent
a room from becoming too hot or cold while you are
sleeping or out of your home. Select any temperature
from 18 to 32C for cooling operation and 10 to 30C for
heating operation.
See page 15

Indoor Unit On/Off Switch


There is a second On/Off switch on the body of the indoor
unit to prevent any problems if the wireless remote
controller is misplaced.
See page 16

Photocatalytic Deodorising Filter


This filter decomposes odours and even removes
bacteria and viruses. This power is maintained simply by
exposing the filter to sunlight once every 6 months.
See page 17

Air-Purifying Filter
The filter removes bacteria and viruses, and impurities
such as dust, pollen and cigarette smoke from the air.

See page 8

Others
Comfort Control
Quick Warming Function

See page 17

During low outdoor temperatures, this function preheats the


compressor to shorten the time required to discharge warm air.

Mould-Proof Air Filter


The air filter net is impregnated with a safe, odourless
mould preventative to make the filter virtually immune to
mould.

Automatic Defrosting
Before starting heating operation, a sensor checks for frost in
the outdoor unit and performs automatic defrosting if necessary
so that only warm air is discharged.

Mould-Proof Operation
Mould-Proof Operation automatically runs fan-only
operation for 1 hour when cooling or dry operation is
stopped. This airflow prevents the generation of mould
and mould odours inside the indoor unit.

Hot-Start Function
After defrosting or when starting heating operation, air is
preheated before discharge to prevent uncomfortable cold
drafts.

See page 17

Wipe-Clean Flat Panel


The flat panel models can be cleaned with only the single
pass of a cloth across their smooth surface. The flat panel
can also be easily removed for more thorough cleaning.

Worry Free
Cooling/Heating Mode Lock
The owner can lock the operation mode to prevent it from being
changed in individual rooms. This is convenient in small hotels.

See page 11

Wiring Error Check


Microcomputer checking and diagnosis of wiring errors during
installation prevents any problems.

Timers

Flexibility

Priority-Room Setting
When this function is set, it is convenient for selecting Inverter
Powerful Operation, Outdoor Unit Quiet Operation and
operation mode. Initial setting is required during installation.

The outdoor units heat exchanger fins are processed


using a special anticorrosion treatment. The surface is
covered with a thin acrylic resin layer to enhance the fins
resistance to acid rain and salt corrosion.

24-Hour On/Off Timer


This timer can be preset to start and stop at any time
within a 24-hour period. The air conditioner is started/
stopped simply by pressing the On/Off timer button on
the wireless remote controller.

Night Set Mode

Chargeless
Charging with additional refrigerant is not required even for
long runs of piping. Available for cooling only type.

Either Side Drain (left or right)


The wall-mounted type indoor unit is designed so that drain
piping can be connected to either the left or right side.

Pressing the Off timer button automatically selects the


Night Set Mode. This function prevents any sudden
change in room temperature by gently raising/lowering
the temperature before the air conditioner stops, so you
can sleep comfortably.
See page 16

See page 15

Refer to page 14 to check the functions offered by individual models.

19

20

Specifications

Specifications and Options

Specifications

Floor/ceiling-suspended dual type


Outdoor units
Cooling only
Heat pump
3MKD75DVM
4MKD75DVM 4MKD100DVM 3MXD68BVMA 4MXD80BVMA
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
Ivory white
Pale ivory
Ivory white
Pale ivory
Hermetically sealed swing type
48/45 *1
46/43 *1
48/45 *1

49/46 *1
735 x 936 x 300
770 x 900 x 320 735 x 936 x 300 908 x 900 x 320
58
56
59
73
55
10 to 46
10 to 46

15 to 15.5
35 (total)
45 (total)
70 (total)
45 (total)
70 (total)
60 (total)
25 (for each room)
Chargeless
20 (for 30 m or more) *2 20 (for 40 m or more) *2
15 (between indoor and outdoor units)

2MKD58DVM

Model name
Power supply
Casing colour
Compressor type
Cooling
Heating
Dimensions (H x W x D)
Machine weight
Cooling
Operation
range
Heating

dB (A)

Sound levels

mm
kg
CDB
CWB
m

Max. piping length


Necessity of additional charge
Max. installation height difference

g/m
m

3MKD58DVM

Notes: *1. Rated sound level/sound level when using outdoor unit quiet operation.
*2. Additional charging of 20 g/m is required for the 3MXD68BVMA when the piping length is 30 m or more and for the 4MXD80BVMA when the piping length is 40 m or more.

Indoor units
Heat pump
Cooling only
FTKD35DVM FTKD50FVM FTKD60FVM FTKD71FVM FTXE25BVMA FTXE35BVMA FTXD50FVM FTXD60FVM FTXD71FVM
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
White
8.9 (314)
9.0 (318) 16.8 (593) 17.5 (618) 18.3 (646)
7.8 (275)
7.7 (272)
16.8 (593) 17.5 (618) 18.3 (646)
8.1 (286)

17.5 (618) 18.7 (660) 19.8 (699)


37/28/25
39/29/26
44/35/32
45/36/33
46/37/34
44/35/32
45/36/33
46/37/34
37/30/27
38/32/29

42/33/30
44/35/32
46/37/34
37/30/27
38/31/28
5 steps, quiet and automatic
Microcomputer control
283 x 800 x 195
290 x 1,050 x 238
273 x 784 x 195
290 x 1,050 x 238
9
12
7.5
12
9.5
9.5
6.4
6.4
9.5
9.5
15.9
12.7
15.9
12.7
18.0
Both liquid and gas pipes

FTKD25DVM

m3/min
(cfm)
dB (A)

mm
kg
mm

<

>

Cooling
Heating
Sound levels* Cooling
(H/L/SL)
Heating
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Liquid (flare)
Piping
connections Gas (flare)
Drain
Heat insulation
External static pressure
Airflow rates
(H)

Cooling only
CDKD25EAVM

m /min
(cfm)

8.7 (307)

35/31/29

mm
kg
9.5

mm

Pa

CDXD35EAVMA

35/31/29

dB(A)

<

Duct-connected type 900/1,100 mm width

>

5 steps, quiet and automatic


Microcomputer control
200 x 700 x 620
21
6.4
12.7
9.5
VP20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
35

12.7

Cooling only
Heat pump
Model name
CDKD25CVM CDKD35CVM CDKD50CVM CDKD60CVM CDXD25CVMA CDXD35CVMA CDXD50CVMA CDXD60CVMA
Power supply
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
9.5 (335)
10.0 (353)
12.0 (424)
16.0 (565)
9.5 (335)
10.0 (353)
12.0 (424)
16.0 (565)
Airflow rates Cooling
m3/min
(H)
(cfm)
Heating

9.5 (335)
10.0 (353)
12.0 (424)
16.0 (565)
37/33/31
38/34/32
37/33/31
38/34/32
35/31/29
35/31/29
Sound levels* Cooling dB (A)
(H/L/SL)
Heating

37/33/31
38/34/32

35/31/29
Fan speed
5 steps, quiet and automatic
Temperature control
Microcomputer control
Dimensions (H x W x D)
200 x 900 x 620
200 x 1,100 x 620
200 x 900 x 620
200 x 1,100 x 620
mm
Machine weight
kg
27
30
27
30
25
25
Liquid (flare)
6.4
Piping
9.5
15.9
9.5
15.9
12.7
12.7
connections Gas (flare) mm
Drain
VP20 (External Dia. 26/Internal Dia. 20)
Heat insulation
Both liquid and gas pipes
External static pressure
Pa
40
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 35 Pa for CDK(X)D-EA and 40 Pa for CDK(X)D-C.
Sound level values for bottom-suction operation can be obtained by adding 6 dB for CDK(X)D-EA and 5 dB for CDK(X)D-C.

Figures are subject to change.

21

No.
1
2

2MKD58D

Item
Air direction adjustment grille
Drain plug

3MKD58D

3MKD75D

3MXD68B
KPW945A4

4MKD75D

4MKD100D

KKP937A4 *1

4MXD80B

KKP945A4 *2

Notes: *1. One set includes 5 pieces for 5 units.


*2. One set includes 1 piece for 1 unit.

Air direction adjustment grille


KPW945A4

Drain plug
KKP937A4

Indoor units
No.

Heat pump

CDKD35EAVM
CDXD25EAVMA
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
8.7 (307)

Outdoor units

Duct-connected type 700 mm width


Model name
Power supply

Measurement conditions
1. Cooling operation data is based on the following conditions: indoor temp.27CDB,19CWB; outdoor temp.35CDB; piping length 7.5 m.
2. Heating operation data is based on the following conditions: indoor temp.20CDB,19CWB; outdoor temp.7CDB, 6CWB; piping length 7.5 m.
3. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

Options

Wall-mounted type
Model name
Power supply
Front panel colour
Airflow rates Cooling
(H)
Heating
Sound levels Cooling
(H/L/SL)
Heating
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Liquid (flare)
Piping
connections Gas (flare)
Drain
Heat insulation

Cooling only
Heat pump
FLK25AVMA FLK35AVMA FLK50AVMA FLK60AVMA
FLX25AVMA FLX35AVMA FLX50AVMA FLX60AVMA
Model name
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
Power supply
Almond white
Front grille colour
7.6 (268)
8.7 (307)
11.4 (402)
12.0 (424)
7.6 (268)
8.7 (307)
11.4 (402)
12.0 (424)
Airflow rates Cooling m3/min
(H)
Heating (cfm)

9.2 (325)
10.0 (353)
12.1 (427)
12.8 (452)
37/31/28
38/32/29
47/39/36
48/41/38
37/31/28
38/32/29
47/39/36
48/41/38
Sound levels Cooling dB (A)
(H/L/SL)
Heating

37/31/28
39/33/30
46/35/32
47/37/34
5 steps, quiet and automatic
Fan speed
Microcomputer control
Temperature control
490 x 1,050 x 200
Dimensions (H x W x D)
mm
Machine weight
16
17
16
17
kg
Liquid (flare)
6.4
Piping
9.5
15.9
9.5
15.9
12.7
12.7
connections Gas (flare) mm
Drain
18.0
Both liquid and gas pipes
Heat insulation

3
4
5
6
7
8
9
10

Item
5-room centralised controller*1
Wiring adaptor for time clock/remote controller*2
(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter*3
Photocatalytic deodorising filter with frame*4
Photocatalytic deodorising filter without frame*4
Air-purifying filter with frame*5
Air-purifying filter without frame*5
Remote controller loss prevention chain
Suction grille
Insulation kit for high humidity

Wall-mounted type
Duct-connected type
Floor/ceilingFTKD25/35D
FTXE25/35B FTK(X)D50/60/71F CDK(X)D25/35EA CDK(X)D25/35/50C CDK(X)D60C suspended dual type
KRC72
KRP413A1S

KAZ970A42

KAF970A42

KAF952B42

KAZ917B41
KAZ917B42
KAF925B41
KAF925B42

KAZ917B41
KAZ917B42
KAF925B41
KAF925B42

KKF917A4

KDT25N32

KDGF19A45
KDT25N50

KDT25N63

Notes: *1. A wiring adaptor (KRP413A1S) is also required for each indoor unit.
*2. Time clock and other devices should be obtained locally.
*3. Filter is a standard accessory. It should be replaced after approximately 3 years.
*4. The photocatalytic deodorising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months.
This accessory is only required if the original filter is damaged or lost, etc.
*5. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.

5-room centralised
controller
KRC72

Titanium apatite photocatalytic


air-purifying filter
KAF952B42

Air-purifying filter without frame


KAF970A42

Remote controller loss


prevention chain
KKF917A4

System configurations
No.
1
2
3
4

Item
Central remote controller*
Unified on/off controller*
Schedule timer*
Interface adaptor for DIII-NET use

Wall-mounted type

Duct-connected type
DCS302CA61
DCS301BA61
DST301BA61
KRP928B2S

Floor/ceiling-suspended dual type

Note: * A wiring adaptor (KRP928B2S) is also required for each indoor unit.

Central remote controller


DCS302CA61

Unified on/off controller


DCS301BA61

Schedule timer
DST301BA61
Figures are subject to change.

22

Capacity tables

Capacity tables

Cooling only type


Outdoor
unit

2MKD58DVM

3MKD58DVM

3MKD75DVM

4MKD75DVM

23

Combinations
of indoor units
25
35
50
25+25
25+35
25+50
35+35
35+50
50+50
25
35
50
25+25
25+35
25+50
35+35
35+50
50+50
25+25+25
25+25+35
25+25+50
25+35+35
25
35
50
60
71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
35+35+35
35+35+50
35+35+60
35+50+50
25
35
50
60
71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71

220 V, 50/60 Hz

Capacity of each indoor unit (kW)


A room
2.50
3.50
5.00
2.50
2.42
1.93
2.90
2.39
2.90
2.50
3.50
5.00
2.50
2.42
1.93
2.90
2.39
2.90
1.93
1.71
1.45
1.52
2.50
3.50
5.00

2.50
2.50
2.37
2.12
1.95
3.50
2.96
2.76
2.48
3.75
3.41
3.10

2.30
2.12
1.88
1.70
1.55
1.98
1.70
1.56
1.43
1.50
1.39
2.50
2.19
2.02
1.94
2.50
3.50
5.00

B room

C room

D room

2.50
3.38
3.87
2.90
3.41
2.90

2.50
3.38
3.87
2.90
3.41
2.90
1.93
1.71
1.45
2.14

6.00
7.10
2.50
3.50
4.73
5.08
5.55
3.50
4.24
4.74
5.02
3.75
4.09
4.40
3.75
3.44
2.30
2.12
1.88
1.70
1.55
2.76
2.39
2.19
2.00
3.00
2.78
2.50
2.19
2.02
2.78

1.93
2.38
2.90
2.14

3.75
4.06
2.30
2.96
3.74
4.10
4.40
2.76
3.41
3.75
4.07
3.00
3.33
2.50
3.12
3.46
2.78

6.00
7.10
2.50
2.50
2.37
2.12
1.95
3.50
2.96
2.76
2.48
3.75
3.41
3.10

2.50
3.50
4.73
5.08
5.55
3.50
4.24
4.74
5.02
3.75
4.09
4.40
3.75
3.44

3.75
4.06

Total capacity (kW)


Rated (Min._ Max.)

Total power consumption (W)


Rated (Min._ Max.)

Total current (A)


Rated (Min._ Max.)

2.50 (1.523.34)
3.50 (1.614.14)
5.00 (1.685.70)
5.00 (1.686.30)
5.80 (1.816.61)
5.80 (2.006.71)
5.80 (1.936.69)
5.80 (2.156.79)
5.80 (2.376.90)
2.50 (1.523.34)
3.50 (1.614.14)
5.00 (1.685.70)
5.00 (1.686.30)
5.80 (1.816.61)
5.80 (2.006.71)
5.80 (1.936.69)
5.80 (2.156.79)
5.80 (2.376.90)
5.79 (2.006.75)
5.80 (2.156.80)
5.80 (2.376.90)
5.80 (2.306.86)
2.50 (1.603.35)
3.50 (1.694.15)
5.00 (1.775.80)
6.00 (1.906.45)
7.10 (2.057.19)
5.00 (1.776.30)
6.00 (1.906.70)
7.10 (2.117.28)
7.20 (2.267.62)
7.50 (2.437.98)
7.00 (2.037.20)
7.20 (2.267.70)
7.50 (2.427.93)
7.50 (2.598.23)
7.50 (2.498.08)
7.50 (2.668.31)
7.50 (2.878.49)
7.50 (2.858.47)
7.50 (3.068.57)
6.90 (2.117.61)
7.20 (2.267.77)
7.50 (2.498.18)
7.50 (2.668.32)
7.50 (2.878.52)
7.50 (2.427.99)
7.50 (2.668.32)
7.50 (2.858.50)
7.50 (3.068.70)
7.50 (2.948.60)
7.50 (3.148.75)
7.50 (2.588.25)
7.50 (2.858.51)
7.50 (3.048.65)
7.50 (3.148.75)
2.50 (1.603.35)
3.50 (1.694.15)
5.00 (1.775.80)
6.00 (1.906.45)
7.10 (2.057.19)
5.00 (1.776.30)
6.00 (1.906.70)
7.10 (2.117.28)
7.20 (2.267.62)
7.50 (2.437.98)
7.00 (2.037.20)
7.20 (2.267.70)
7.50 (2.427.93)
7.50 (2.598.23)
7.50 (2.498.08)
7.50 (2.668.31)
7.50 (2.878.49)
7.50 (2.858.47)
7.50 (3.068.57)

810 (4501,090)
1,240 (4701,570)
1,710 (5402,140)
1,600 (4802,290)
2,050 (5002,390)
1,840 (5702,340)
2,010 (5402,390)
1,810 (6202,350)
1,620 (6202,120)
810 (4501,090)
1,240 (4701,570)
1,710 (5402,140)
1,600 (4802,290)
2,050 (5002,390)
1,840 (5702,340)
2,010 (5402,390)
1,810 (6202,350)
1,620 (6202,120)
1,700 (5302,170)
1,690 (5802,170)
1,530 (5901,960)
1,670 (6202,190)
780 (4701,100)
1,260 (4901,530)
1,680 (5702,040)
2,280 (5902,560)
2,910 (6203,000)
1,590 (5002,370)
2,180 (5202,620)
2,550 (6002,710)
2,570 (6402,960)
2,740 (6803,150)
2,760 (5702,950)
2,570 (6503,020)
2,760 (6803,060)
2,730 (7403,260)
2,590 (6503,090)
2,560 (6803,150)
2,540 (7503,430)
2,550 (7503,380)
2,520 (8003,490)
2,210 (5702,670)
2,390 (6102,810)
2,440 (6202,870)
2,410 (6602,950)
2,400 (7203,110)
2,490 (6502,980)
2,410 (6602,990)
2,400 (7003,050)
2,360 (7603,260)
2,380 (6702,970)
2,310 (7303,080)
2,510 (7003,110)
2,400 (7303,140)
2,370 (7603,260)
2,270 (7303,030)
780 (4701,100)
1,260 (4901,530)
1,680 (5702,040)
2,280 (5902,560)
2,910 (6203,000)
1,590 (5002,370)
2,180 (5202,620)
2,550 (6002,710)
2,570 (6402,960)
2,740 (6803,150)
2,760 (5702,950)
2,570 (6503,020)
2,760 (6803,060)
2,730 (7403,260)
2,590 (6503,090)
2,560 (6803,150)
2,540 (7503,430)
2,550 (7503,380)
2,520 (8003,490)

4.1 (2.2 5.4)


5.9 (2.3 7.6)
7.9 (2.5 9.9)
7.4 (2.210.6)
9.4 (2.311.1)
8.5 (2.610.8)
9.3 (2.511.1)
8.3 (2.910.9)
7.5 (2.9 9.8)
4.1 (2.2 5.4)
5.9 (2.3 7.6)
7.9 (2.5 9.9)
7.4 (2.210.6)
9.4 (2.311.1)
8.5 (2.610.8)
9.3 (2.511.1)
8.3 (2.910.9)
7.5 (2.9 9.8)
7.8 (2.410.0)
7.8 (2.710.1)
7.1 (2.7 9.0)
7.7 (2.910.1)
3.9 (2.4 5.5)
6.0 (2.4 7.4)
7.8 (2.6 9.4)
10.5 (2.711.8)
13.4 (2.913.8)
7.4 (2.410.9)
10.1 (2.412.0)
11.8 (2.812.5)
11.8 (3.013.6)
12.6 (3.114.5)
12.7 (2.613.6)
11.8 (3.013.9)
12.7 (3.114.1)
12.6 (3.515.0)
11.9 (3.014.3)
11.8 (3.114.5)
11.7 (3.515.8)
11.8 (3.515.6)
11.6 (3.716.1)
10.3 (2.612.3)
11.0 (2.813.0)
11.3 (2.913.2)
11.1 (3.013.6)
11.1 (3.414.4)
11.5 (3.013.7)
11.1 (3.013.7)
11.1 (3.214.1)
10.9 (3.615.0)
11.0 (3.113.7)
10.7 (3.414.2)
11.6 (3.214.4)
11.1 (3.414.5)
10.9 (3.615.0)
10.5 (3.414.0)
3.9 (2.4 5.5)
6.0 (2.4 7.4)
7.8 (2.6 9.4)
10.5 (2.711.8)
13.4 (2.913.8)
7.4 (2.410.9)
10.1 (2.412.0)
11.8 (2.812.5)
11.8 (3.013.6)
12.6 (3.114.5)
12.7 (2.613.6)
11.8 (3.013.9)
12.7 (3.114.1)
12.6 (3.515.0)
11.9 (3.014.3)
11.8 (3.114.5)
11.7 (3.515.8)
11.8 (3.515.6)
11.6 (3.716.1)

Outdoor
unit

4MKD75DVM

4MKD100DVM

Combinations
of indoor units
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
35+35+35
35+35+50
35+35+60
35+50+50
25+25+25+25
25+25+25+35
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+50
25+35+35+35
25
35
50
60
71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
71+71
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
25+50+71
25+60+60
25+60+71
35+35+35
35+35+50
35+35+60
35+35+71
35+50+50
35+50+60
35+50+71
35+60+60
50+50+50
25+25+25+25
25+25+25+35
25+25+25+50
25+25+25+60
25+25+25+71
25+25+35+35
25+25+35+50
25+25+35+60
25+25+35+71
25+25+50+50

Capacity of each indoor unit (kW)


A room
2.30
2.12
1.88
1.70
1.55
1.98
1.70
1.56
1.43
1.50
1.39
2.50
2.19
2.02
1.94
1.87
1.70
1.50
1.39
1.56
1.39
1.44
2.50
3.50
5.00

B room
2.30
2.12
1.88
1.70
1.55
2.76
2.39
2.19
2.00
3.00
2.78
2.50
2.19
2.02
2.78
1.87
1.70
1.50
1.39
1.56
1.39
2.02

C room
2.30
2.96
3.74
4.10
4.40
2.76
3.41
3.75
4.07
3.00
3.33
2.50
3.12
3.46
2.78
1.87
1.70
1.50
1.39
2.19
1.94
2.02

D room

1.87
2.40
3.00
3.33
2.19
2.78
2.02

6.00
7.10
2.50
2.50
2.50
2.24
1.99
3.50
3.11
2.82
2.66
3.89
3.74
3.60

2.50
2.23
1.95
1.87
2.18
2.08
1.87
1.81
1.74
1.77
1.74
1.68
1.70
1.60
2.70
2.53
2.46
2.38
2.43
2.36
2.10
2.26
3.32
1.95
1.86
1.78
1.73
1.68
1.80
1.73
1.68
1.70
1.66

2.50
3.50
5.00
5.36
5.64
3.50
4.44
4.83
5.38
3.89
4.48
5.11
4.34
4.19
4.82
2.50
2.23
1.95
1.87
2.18
2.91
2.62
2.53
2.45
3.56
3.45
3.37
4.04
3.60
2.70
2.53
2.46
2.38
3.45
3.38
3.00
3.87
3.32
1.95
1.86
1.78
1.73
1.68
1.80
1.73
1.68
1.70
1.66

4.34
4.97
4.82
2.50
3.14
3.88
4.48
4.35
2.91
3.73
4.33
4.97
3.56
4.14
4.77
4.04
4.80
2.70
3.61
4.19
4.84
3.45
4.04
4.90
3.87
3.32
1.95
1.86
1.78
1.73
1.68
2.53
2.42
2.36
2.30
3.32

1.95
2.64
3.55
4.14
4.78
2.53
3.46
4.05
4.30
3.32

Total capacity (kW)


Rated (Min._ Max.)

Total power consumption (W)


Rated (Min._ Max.)

Total current (A)


Rated (Min._ Max.)

6.90 (2.11 7.61)


7.20 (2.26 7.77)
7.50 (2.49 8.18)
7.50 (2.66 8.32)
7.50 (2.87 8.52)
7.50 (2.42 7.99)
7.50 (2.66 8.32)
7.50 (2.85 8.50)
7.50 (3.06 8.70)
7.50 (2.94 8.60)
7.50 (3.14 8.75)
7.50 (2.58 8.25)
7.50 (2.85 8.51)
7.50 (3.04 8.65)
7.50 (3.14 8.75)
7.48 (2.49 8.34)
7.50 (2.66 8.50)
7.50 (2.94 8.69)
7.50 (3.14 8.80)
7.50 (2.85 8.62)
7.50 (3.14 8.80)
7.50 (3.04 8.75)
2.50 (1.95 3.60)
3.50 (2.05 4.50)
5.00 (2.20 6.20)
6.00 (2.30 6.70)
7.10 (2.41 7.20)
5.00 (2.20 6.70)
6.00 (2.30 7.00)
7.50 (2.45 8.20)
7.60 (2.55 8.60)
7.63 (2.66 8.80)
7.00 (2.40 7.70)
7.55 (2.55 8.50)
7.65 (2.65 8.70)
8.04 (2.76 9.25)
7.78 (2.70 9.00)
8.22 (2.80 9.50)
8.71 (2.91 9.60)
8.68 (2.90 9.70)
9.16 (3.01 9.80)
9.64 (3.12 9.90)
7.50 (2.45 8.40)
7.60 (2.55 8.60)
7.78 (2.70 9.20)
8.22 (2.80 9.70)
8.71 (2.91 9.75)
7.90 (2.65 9.00)
8.22 (2.80 9.70)
8.67 (2.90 9.75)
9.16 (3.01 9.95)
8.89 (2.95 9.80)
9.33 (3.0510.00)
9.82 (3.1610.35)
9.78 (3.1510.30)
10.00 (3.2610.45)
8.10 (2.75 9.30)
8.67 (2.90 9.75)
9.11 (3.00 9.95)
9.60 (3.1110.30)
9.33 (3.0510.20)
9.78 (3.1510.30)
10.00 (3.2610.45)
10.00 (3.2510.40)
9.96 (3.2010.35)
7.80 (2.70 9.45)
8.22 (2.80 9.70)
8.89 (2.9510.10)
9.33 (3.0510.20)
9.82 (3.1610.30)
8.66 (2.90 9.90)
9.34 (3.0510.25)
9.77 (3.1510.40)
10.00 (3.2610.50)
9.96 (3.2010.45)

2,210 (5702,670)
2,390 (6102,810)
2,440 (6202,870)
2,410 (6602,950)
2,400 (7203,110)
2,490 (6502,980)
2,410 (6602,990)
2,400 (7003,050)
2,360 (7603,260)
2,380 (6702,970)
2,310 (7303,080)
2,510 (7003,110)
2,400 (7303,140)
2,370 (7603,260)
2,270 (7303,030)
2,290 (5902,930)
2,270 (6303,080)
2,240 (6503,110)
2,220 (6903,220)
2,250 (6703,180)
2,230 (6903,220)
2,240 (7303,290)
660 (5101,050)
1,050 (5401,530)
1,660 (5402,490)
1,950 (5302,310)
2,700 (5602,760)
1,470 (5202,510)
2,090 (5402,820)
2,920 (5503,460)
2,800 (5403,070)
2,470 (5703,270)
3,080 (5703,790)
3,180 (5703,900)
2,420 (5603,170)
2,800 (5903,810)
2,660 (5803,640)
2,580 (5803,440)
2,960 (6003,540)
2,620 (5803,190)
2,980 (6003,280)
3,250 (6303,370)
2,520 (5303,100)
2,800 (5503,320)
2,380 (5603,340)
2,400 (5603,300)
2,720 (5903,350)
2,860 (5803,820)
2,700 (5903,920)
2,700 (5803,350)
3,080 (6103,550)
2,910 (6003,470)
3,010 (6003,330)
3,310 (6303,470)
3,340 (6103,540)
3,490 (6403,700)
2,960 (6003,820)
3,090 (6103,980)
3,040 (6103,550)
3,500 (6303,940)
3,300 (6203,910)
3,410 (6303,820)
3,580 (6503,780)
3,470 (6403,750)
3,450 (6403,760)
2,210 (5503,220)
2,480 (5703,460)
2,740 (5903,510)
2,950 (6003,540)
3,370 (6203,740)
2,800 (5903,460)
3,080 (6103,760)
3,340 (6203,790)
3,330 (6403,740)
3,470 (6303,760)

10.3 (2.612.3)
11.0 (2.813.0)
11.3 (2.913.2)
11.1 (3.013.6)
11.1 (3.414.4)
11.5 (3.013.7)
11.1 (3.013.7)
11.1 (3.214.1)
10.9 (3.615.0)
11.0 (3.113.7)
10.7 (3.414.2)
11.6 (3.214.4)
11.1 (3.414.5)
10.9 (3.615.0)
10.5 (3.414.0)
10.6 (2.713.5)
10.5 (2.914.2)
10.3 (3.014.4)
10.2 (3.214.8)
10.4 (3.114.7)
10.3 (3.214.8)
10.3 (3.415.1)
3.1 (2.4 5.0)
5.0 (2.6 7.2)
7.9 (2.611.8)
9.2 (2.510.9)
12.4 (2.612.7)
6.7 (2.411.5)
9.6 (2.512.9)
13.4 (2.515.9)
12.9 (2.514.1)
11.3 (2.615.0)
14.1 (2.617.4)
14.6 (2.617.9)
11.1 (2.614.6)
12.9 (2.717.5)
12.2 (2.716.7)
11.8 (2.715.8)
13.6 (2.816.3)
12.0 (2.714.6)
13.7 (2.815.1)
14.9 (2.915.5)
11.6 (2.414.2)
12.9 (2.515.2)
10.9 (2.615.3)
11.0 (2.615.2)
12.5 (2.715.4)
13.1 (2.717.5)
12.4 (2.718.0)
12.4 (2.715.4)
14.1 (2.816.3)
13.4 (2.815.9)
13.8 (2.815.3)
15.2 (2.915.9)
15.3 (2.816.3)
16.0 (2.917.0)
13.6 (2.817.5)
14.2 (2.818.3)
14.0 (2.816.3)
16.1 (2.918.1)
15.2 (2.818.0)
15.7 (2.917.5)
16.4 (3.017.4)
15.9 (2.917.2)
15.8 (2.917.3)
10.1 (2.514.8)
11.4 (2.615.9)
12.6 (2.716.1)
13.5 (2.816.3)
15.5 (2.817.2)
12.9 (2.715.9)
14.1 (2.817.3)
15.3 (2.817.4)
15.3 (2.917.2)
15.9 (2.917.3)

24

Capacity tables

Capacity tables

Heat pump type


Outdoor
unit

4MKD100DVM

Combinations
of indoor units
25+35+35+35
25+35+35+50
25+35+35+60
35+35+35+35
35+35+35+50

Capacity of each indoor unit (kW)


A room
1.75
1.68
1.61
2.39
2.26

B room
2.45
2.36
2.26
2.39
2.26

C room
2.45
2.36
2.26
2.39
2.26

D room
2.45
3.38
3.87
2.39
3.22

Total capacity (kW)


Rated (Min._ Max.)

Total power consumption (W)


Rated (Min._ Max.)

Total current (A)


Rated (Min._ Max.)

9.10 (3.0010.00)
9.78 (3.1510.30)
10.00 (3.2510.40)
9.56 (3.1010.10)
10.00 (3.2510.40)

3,170 (6103,670)
3,490 (6303,710)
3,450 (6403,750)
3,630 (6403,900)
3,640 (6503,820)

14.6 (2.816.9)
16.0 (2.917.0)
15.8 (2.917.2)
16.7 (2.917.9)
16.7 (3.017.5)

Outdoor
unit

Notes: 1. Data is based on the following conditions: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB.
2. Total capacity of connected indoor units is: up to 10.0 kW to the 2/3MKD58D; up to 13.5 kW to the 3/4MKD75D; up to 15.6 kW to the 4MKD100D.

4MXD80BVMA

Heat pump type


Outdoor
unit

3MXD68BVMA
Cooling
capacity

3MXD68BVMA
Heating
capacity

4MXD80BVMA
Cooling
capacity

25

Combinations
of indoor units
25
35
50
60
25+25
25+35
25+50
25+60
35+35
35+50
35+60
50+50
50+60
25+25+25
25+25+35
25+25+50
25+25+60
25+35+35
25+35+50
35+35+35
25
35
50
60
25+25
25+35
25+50
25+60
35+35
35+50
35+60
50+50
50+60
25+25+25
25+25+35
25+25+50
25+25+60
25+35+35
25+35+50
35+35+35
25
35
50
60
71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
25+25+25

220 V, 50/60 Hz
Capacity of each indoor unit (kW)
A room
2.50
3.50
5.00

B room

2.50
2.42
2.08
1.88
3.00
2.64
2.42
3.32
3.09
2.08
1.88
1.66
1.55
1.78
1.55
2.26
3.86
4.42
6.13

2.50
3.38
4.16

3.55
3.18
2.83
2.53
4.00
3.54
3.17
4.30
3.91
2.86
2.53
2.15
1.95
2.26
1.95
2.86
2.50

3.55
4.45
5.67

C room

D room

6.00

4.52
3.00
3.76
4.14
3.32
2.08
1.88
1.66
1.55
2.51
2.16
2.26

3.71
2.08
2.64
3.32
3.70
2.51
3.09
2.26

7.32

6.07
4.00
5.06
5.43
4.30
2.86
2.53
2.15
1.95
3.17
2.74
2.86

4.69
2.86
3.54
4.30
4.70
3.17
3.91
2.86

3.50
5.00
6.00
7.10
2.50
2.50
2.40
2.18
1.98
3.50
3.06

2.40

2.50
3.50
4.79
5.24
5.62
3.50
4.36
2.77
2.52
3.79
3.64
3.31

2.40

4.75
5.10
3.79
4.36
4.69
4.00
3.66
2.40

4.00
4.34

Total capacity (kW)


Rated (Min._ Max.)

Total power consumption (W)


Rated (Min._ Max.)

Total current (A)


Rated (Min._ Max.)

2.50 (1.583.02)
3.50 (1.673.92)
5.00 (1.755.22)
6.00 (1.886.16)
5.00 (1.755.31)
5.80 (1.886.24)
6.24 (2.096.64)
6.40 (2.246.78)
6.00 (2.016.45)
6.40 (2.246.78)
6.56 (2.407.05)
6.64 (2.477.21)
6.80 (2.637.27)
6.24 (2.096.94)
6.40 (2.246.99)
6.64 (2.477.26)
6.80 (2.637.41)
6.80 (2.407.23)
6.80 (2.637.41)
6.78 (2.557.38)
3.86 (1.464.75)
4.42 (1.615.40)
6.13 (1.847.40)
7.32 (2.008.35)
7.10 (2.147.95)
7.63 (2.268.40)
8.50 (2.448.87)
8.60 (2.559.15)
8.00 (2.388.55)
8.60 (2.559.15)
8.60 (2.689.25)
8.60 (2.749.45)
8.60 (2.869.55)
8.58 (2.809.40)
8.60 (2.959.41)
8.60 (3.189.55)
8.60 (3.339.60)
8.60 (3.109.45)
8.60 (3.339.60)
8.58 (3.259.55)
2.50 (1.583.30)
3.50 (1.674.11)
5.00 (1.755.87)
6.00 (1.886.43)
7.10 (2.037.14)
5.00 (1.756.16)
6.00 (1.886.59)
7.19 (2.097.29)
7.42 (2.237.82)
7.60 (2.408.04)
7.00 (2.017.19)
7.42 (2.237.82)
7.52 (2.398.02)
7.62 (2.578.32)
7.58 (2.478.31)
8.00 (2.648.41)
8.00 (2.848.44)
8.00 (2.828.49)
8.00 (3.038.46)
7.20 (2.097.53)

830 (4401,150)
1,250 (4601,530)
1,810 (5301,920)
2,700 (5602,970)
1,710 (4701,940)
2,290 (5002,720)
2,090 (5602,380)
2,220 (6002,520)
2,430 (5302,720)
2,260 (6102,560)
2,390 (6402,760)
2,100 (6102,380)
2,190 (6402,380)
1,860 (5302,360)
1,980 (5702,410)
1,940 (5802,360)
2,110 (6202,610)
2,170 (6102,680)
2,110 (6202,610)
2,150 (6602,780)
1,340 (4801,730)
1,630 (5402,130)
2,050 (4602,820)
2,650 (4803,320)
2,340 (5203,030)
2,610 (5503,330)
2,830 (5403,060)
2,840 (5603,110)
2,830 (5703,240)
2,870 (5603,150)
2,790 (5803,130)
2,460 (5502,880)
2,400 (5702,870)
2,760 (6203,170)
2,610 (6503,170)
2,430 (6402,850)
2,410 (6702,820)
2,520 (6803,170)
2,380 (6702,860)
2,410 (7303,070)
750 (4501,040)
1,210 (4701,480)
1,640 (5402,190)
2,240 (5602,600)
2,800 (5903,160)
1,560 (4802,260)
2,140 (5002,690)
2,460 (5702,730)
2,590 (6003,140)
2,740 (6503,470)
2,530 (5403,060)
2,550 (6103,300)
2,660 (6503,310)
2,830 (7003,600)
2,630 (6203,240)
2,850 (6603,230)
2,670 (7103,420)
2,680 (7103,310)
2,650 (7603,410)
2,600 (5402,760)

3.9 (2.1 5.4)


5.8 (2.1 7.1)
8.3 (2.4 8.8)
12.4 (2.613.6)
7.9 (2.2 8.9)
10.5 (2.312.5)
9.6 (2.610.9)
10.2 (2.811.6)
11.2 (2.412.5)
10.4 (2.811.8)
11.0 (2.912.7)
9.6 (2.810.9)
10.1 (2.910.9)
8.5 (2.410.8)
9.1 (2.611.1)
8.9 (2.710.8)
9.7 (2.812.0)
10.0 (2.812.3)
9.7 (2.812.0)
9.9 (3.012.8)
6.2 (2.2 8.0)
7.5 (2.5 9.8)
9.4 (2.112.9)
12.2 (2.215.2)
10.7 (2.413.9)
12.0 (2.515.3)
13.0 (2.514.0)
13.0 (2.614.3)
13.0 (2.614.9)
13.2 (2.614.5)
12.8 (2.714.4)
11.3 (2.513.2)
11.0 (2.613.2)
12.7 (2.814.6)
12.0 (3.014.6)
11.2 (2.913.1)
11.1 (3.112.9)
11.6 (3.114.6)
10.9 (3.113.1)
11.1 (3.414.1)
3.9 (2.4 5.4)
5.8 (2.2 7.1)
7.6 (2.510.2)
10.4 (2.612.1)
12.9 (2.714.5)
7.2 (2.210.5)
10.0 (2.312.6)
11.3 (2.612.5)
11.9 (2.814.4)
12.6 (3.015.9)
11.6 (2.514.0)
11.7 (2.815.2)
12.2 (3.015.2)
13.0 (3.216.5)
12.1 (2.814.9)
13.1 (3.014.8)
12.3 (3.315.7)
12.3 (3.315.2)
12.2 (3.515.7)
11.9 (2.512.7)

Cooling
capacity

4MXD80BVMA
Heating
capacity

Combinations
of indoor units
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
35+35+35
35+35+50
35+35+60
35+50+50
25+25+25+25
25+25+25+35
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+50
25+35+35+35
25
35
50
60
71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
35+35+35
35+35+50
35+35+60
35+50+50
25+25+25+25
25+25+25+35
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+50
25+35+35+35

220 V, 50/60 Hz
Capacity of each indoor unit (kW)
A room
2.18
1.94
1.82
1.65
2.01
1.82
1.67
1.53
1.60
1.48
2.63
2.34
2.15
2.08
1.94
1.82
1.60
1.48
1.67
1.48
1.55
3.86

B room
2.18
1.94
1.82
1.65
2.82
2.55
2.33
2.14
3.20
2.96
2.63
2.33
2.15
2.96
1.94
1.82
1.60
1.48
1.67
1.48
2.15

C room
3.06
3.89
4.36
4.70
2.82
3.63
4.00
4.33
3.20
3.56
2.63
3.33
3.70
2.96
1.94
1.82
1.60
1.48
2.33
2.07
2.15

D room

1.94
2.54
3.20
3.56
2.33
2.97
2.15

4.42
6.13
7.32
8.31
3.55
3.18
2.88
2.62
2.40
4.13
3.66

2.88
2.62
2.33
2.18
1.98
2.52
2.18
2.00
1.83
1.92
1.78
3.16
2.80
2.58
2.48
2.33
2.18
1.92
1.78
2.00
1.78
1.86

3.55
4.45
5.75
6.28
6.82
4.13
5.24
3.39
3.13
4.67
4.36
3.97

2.88
2.62
2.33
2.18
1.98
3.38
3.05
2.80
2.56
3.84
3.56
3.16
2.80
2.58
3.56
2.33
2.18
1.92
1.78
2.00
1.78
2.58

5.80
6.36
4.67
5.24
5.63
4.80
4.40
2.88
3.96
4.66
5.24
5.64
3.38
4.37
4.80
5.21
3.84
4.26
3.16
4.00
4.44
3.56
2.33
2.18
1.92
1.78
2.80
2.49
2.58

4.80
5.20

2.33
3.06
3.84
4.26
2.80
3.55
2.58

Total capacity (kW)


Rated (Min._ Max.)

Total power consumption (W)


Rated (Min._ Max.)

Total current (A)


Rated (Min._ Max.)

7.42 (2.237.92)
7.77 (2.478.17)
8.00 (2.648.61)
8.00 (2.848.66)
7.65 (2.398.02)
8.00 (2.648.61)
8.00 (2.828.64)
8.00 (3.038.73)
8.00 (2.918.67)
8.00 (3.118.85)
7.89 (2.568.22)
8.00 (2.828.64)
8.00 (3.018.82)
8.00 (3.119.10)
7.76 (2.478.41)
8.00 (2.648.61)
8.00 (2.919.10)
8.00 (3.119.19)
8.00 (2.828.90)
8.00 (3.119.19)
8.00 (3.019.14)
3.86 (1.47 4.81)
4.42 (1.63 5.00)
6.13 (1.86 8.19)
7.32 (2.02 8.79)
8.31 (2.19 9.45)
7.10 (2.16 9.40)
7.63 (2.28 9.58)
8.63 (2.4610.35)
8.90 (2.5810.39)
9.22 (2.7210.44)
8.26 (2.40 9.81)
8.90 (2.5810.39)
9.19 (2.7110.43)
9.49 (2.8410.48)
9.34 (2.7710.47)
9.60 (2.8910.49)
9.60 (3.0210.54)
9.60 (3.0110.52)
9.60 (3.1410.58)
8.64 (2.8310.40)
8.90 (2.9810.47)
9.32 (3.2110.56)
9.60 (3.3610.63)
9.60 (3.5210.70)
9.18 (3.1310.53)
9.60 (3.3610.63)
9.60 (3.5110.69)
9.60 (3.6710.76)
9.60 (3.5810.73)
9.60 (3.7310.79)
9.47 (3.2810.60)
9.60 (3.5110.69)
9.60 (3.6610.76)
9.60 (3.7310.79)
9.31 (3.5410.57)
9.60 (3.7210.63)
9.60 (4.0010.73)
9.60 (4.1910.79)
9.60 (3.9110.70)
9.60 (4.1910.80)
9.60 (4.0910.76)

2,610 (5803,060)
2,640 (5902,950)
2,800 (6303,170)
2,640 (6803,340)
2,670 (6203,130)
2,730 (6303,170)
2,660 (6703,160)
2,590 (7203,400)
2,550 (6403,220)
2,490 (6903,220)
2,740 (6703,230)
2,650 (6803,240)
2,610 (7203,240)
2,510 (6903,290)
2,630 (5602,910)
2,780 (6003,080)
2,560 (6203,220)
2,410 (6603,270)
2,580 (6403,370)
2,420 (6603,290)
2,470 (6903,460)
1,320 (4401,990)
1,590 (4902,110)
1,620 (4202,930)
2,170 (4403,290)
2,740 (4803,660)
1,900 (4703,440)
2,160 (5003,470)
2,470 (4903,470)
2,600 (5103,460)
2,620 (5303,280)
2,530 (5203,590)
2,600 (5103,480)
2,610 (5303,270)
2,630 (5503,160)
2,620 (5003,310)
2,640 (5203,170)
2,590 (5403,120)
2,590 (5403,110)
2,550 (5603,110)
2,410 (5603,430)
2,590 (5903,470)
2,590 (5803,340)
2,600 (6103,140)
2,540 (6303,130)
2,590 (6203,320)
2,600 (6103,160)
2,550 (6303,100)
2,470 (6702,990)
2,510 (6003,150)
2,450 (6203,040)
2,600 (6603,160)
2,550 (6403,110)
2,490 (6703,010)
2,450 (6303,010)
2,410 (6403,130)
2,460 (6803,020)
2,420 (6703,060)
2,400 (7103,010)
2,430 (7203,000)
2,400 (7102,980)
2,410 (7602,990)

12.0 (2.714.0)
12.1 (2.713.5)
12.9 (2.914.6)
12.1 (3.115.3)
12.3 (2.814.4)
12.5 (2.914.6)
12.2 (3.114.5)
11.9 (3.315.6)
11.7 (2.914.8)
11.4 (3.214.8)
12.6 (3.114.8)
12.2 (3.114.9)
12.0 (3.314.9)
11.5 (3.215.1)
12.1 (2.613.4)
12.8 (2.814.1)
11.9 (2.914.9)
11.2 (3.115.2)
11.8 (2.915.5)
11.1 (3.015.1)
11.3 (3.215.9)
6.2 (2.1 9.3)
7.4 (2.3 9.8)
7.4 (1.913.5)
10.0 (2.015.1)
12.6 (2.216.8)
8.7 (2.215.8)
9.9 (2.315.9)
11.3 (2.215.9)
11.9 (2.315.9)
12.0 (2.415.1)
11.6 (2.416.5)
11.9 (2.316.0)
12.0 (2.415.0)
12.1 (2.514.5)
12.0 (2.315.2)
12.1 (2.414.6)
11.9 (2.514.3)
11.9 (2.514.3)
11.7 (2.614.3)
11.1 (2.615.7)
11.9 (2.715.9)
11.9 (2.715.3)
11.9 (2.814.4)
11.7 (2.914.4)
11.9 (2.815.2)
11.9 (2.814.5)
11.7 (2.914.2)
11.3 (3.113.7)
11.5 (2.814.5)
11.2 (2.814.0)
11.9 (3.014.5)
11.7 (2.914.3)
11.4 (3.113.8)
11.2 (2.913.8)
11.1 (2.914.4)
11.3 (3.113.9)
11.1 (3.114.0)
11.0 (3.313.8)
11.2 (3.313.8)
11.0 (3.313.7)
11.1 (3.513.7)

Notes: 1. Cooling operation data is based on the following conditions: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB.
2. Heating operation data is based on the following conditions: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB.
3. The total capacity of connected indoor units to the 3MXD68B is up to 11.0 kW, and to the 4MXD80B is up to 13.5 kW.
4. A single indoor unit cannot be connected.

26

Das könnte Ihnen auch gefallen