MILL REJECT SYSTEM UNIT # 2

MILL - A
SR.NO. 1 2 3 4 5 6 7 8 PROBLEMS PV 1 connection bolts are not installed (8 bolts) PV 1 to pyrate hopper connection bolt are not installed (8 bolts) PV 3 connection bolt are not installed (4 bolts) PV 4 connection bolt are not installed (5 bolts) limit switches are not installed in plate valves. instrument air line is not connected. level transmiiter is not installed. air line from compressor and to silo is not connected.

MILL - B
1 2 3 4 5 6 7 8 PV 1 connection bolts are not installed (8 bolts) PV 1 to pyrate hopper connection bolt are not installed (8 bolts) PV 3 connection bolt are not installed (4 bolts) PV 4 connection bolt are not installed (5 bolts) limit switches are not installed in plate valves. instrument air line is not connected. HIGH level transmiiter is not installed. air line from compressor and to silo is not connected.

MILL - C
1 2 3 4 5 6 7 8 PV 1 connection bolts are not installed (8 bolts) PV 1 to pyrate hopper connection bolt are not installed (8 bolts) PV 3 connection bolt are not installed (4 bolts) PV 4 connection bolt are not installed (5 bolts) limit switches are not installed in plate valves. instrument air line is not connected. HIGH level transmiiter is not installed. air line from compressor and to silo is not connected.

MILL - D
1 2 3 4 5 6 7 8 PV 1 connection bolts are not installed (8 bolts) PV 1 to pyrate hopper connection bolt are not installed (8 bolts) PV 3 connection bolt are not installed (4 bolts) PV 4 connection bolt are not installed (5 bolts) limit switches are not installed in plate valves. instrument air line is not connected. level transmiiter is not installed. air line from compressor and to silo is not connected.

MILL - E
1 2 3 4 5 6 7 PV 1 connection bolts are not installed (8 bolts) PV 1 to pyrate hopper connection bolt are not installed (8 bolts) PV 3 connection bolt are not installed (4 bolts) PV 4 connection bolt are not installed (5 bolts) limit switches are not installed in plate valves. instrument air line is not connected. LOW level transmiiter is not installed.

air line from compressor and to silo is not connected.

MILL REJECT SYSTEM UNIT # 2


MILL - F
SR.NO. 1 2 3 4 5 6 PROLEMS PV 1 connection bolts are not installed (8 bolts) PV 1 to pyrate hopper connection bolt are not installed.(8 bolts) PV 3 and PV 4 plate valves are not installed. limit switches are not installed in plate valves. air line from compressor and to silo is not connected. instrument air line is not connected.

MILL - G
1 2 3 4 5 6 7 PV 1 connection bolts are not installed (8 bolts) PV 1 to pyrate hopper connection bolt are not installed (8 bolts) PV 3 connection bolt are not installed (4 bolts) PV 4 connection bolt are not installed (5 bolts) limit switches are not installed in plate valves. instrument air line is not connected. air line from compressor and to silo is not connected.

MILL - H
1 2 3 4 5 6 7 PV 1 connection bolts are not installed (8 bolts) PV 1 to pyrate hopper connection bolt are not installed (8 bolts) PV 3 connection bolt are not installed (4 bolts) PV 4 connection bolt are not installed (5 bolts) limit switches are not installed in plate valves. instrument air line is not connected. air line from compressor and to silo is not connected.

MILL - J
1 2 3 4 5 6 7 PV 1 connection bolts are not installed (8 bolts) PV 1 to pyrate hopper connection bolt are not installed (8 bolts) PV 3 connection bolt are not installed (4 bolts) PV 4 connection bolt are not installed (5 bolts) limit switches are not installed in plate valves. instrument air line is not connected. air line from compressor and to silo is not connected.

MILL - K
1 2 3 4 5 6 7 8 9 PV 1 connection bolts are not installed (8 bolts) PV 1 to pyrate hopper connection bolt are not installed (8 bolts) PV 3 connection bolt are not installed (4 bolts) PV 4 connection bolt are not installed (5 bolts) limit switches are not installed in plate valves. instrument air line is not connected. HIGH level transmiiter is not installed. air line from compressor and to silo is not connected. vessel pressure gaugae is damaged in panel.

MILL REJECT SYSTEM UNIT # 2


Sump pump
1 2 In left side sump pump greacing point cap is missing Right side sump pump is not installed.

compressor B
1 2 3 4 5 H.P. suction gauge is not installed. pressure switch is not installed. Load Unload pressure switch is not erected. copper tubing missing. Load unload solenoid is not connected.