Common features
Independent connection of control and power terminals and easier cable guiding.
Contactors
Independent screw connection. Allows independent wiring of control and power terminals at any time, whether in the workshop or on site Easier cable guiding.
Freedom
Reliability
Up to 2 add-on modules can be combined on the same appliance at the same time. Higher loads, up to 25 A, for the new range of power contactors.
Performance
Ergonomic handle
zone 2
zone 1
Pulse operating latching relays Control voltage Type of contacts Cat. No Signalling auxiliary Auxiliary Auxiliary device device for for general centralised centralised control control
In
041 60 041 61 041 65 041 66 041 62 041 68 041 71 041 85 041 87 041 88 041 85 041 86
zone 3
zone 2
zone 1
Power contactors without handle Control voltage Imax 16 A - 250 V A 24 V 25 A - 250 V A 25 A - 400 V A 16 A - 250 V A 25 A - 250 V A Type of contacts N/C + N/O 2 N/O 4 N/O N/C + N/O 2 N/O 2 N/O 2 N/C 230 V A 4 N/O 25 A - 400 V A 63 A - 250 V A 63 A - 400 V A 100 A - 400 V A 4 N/C 2 N/O + 2 N/C 2 N/O 4 N/O 4 N/O Cat. No 041 14 041 16 041 17 041 26 041 49
(1)
No of modules 1 1 2 1 1 1 1 2 2 2 2 3 6
Signalling auxiliary 041 85 041 85 041 83 041 85 041 85 041 85 041 85 041 83 041 83 041 83 040 85 040 85 035 45
Power contactors with handle Control voltage Imax 25 A - 250 V A 25 A - 400 V A 24 V 40 A - 250 V A 40 A - 400 V A 63 A - 250 V A 63 A - 400 V A 25 A - 250 V A 25 A - 400 V A 40 A - 250 V A 40 A - 400 V A 230 V A 63 A - 250 V A Type of contacts 2 N/O 4 N/O 2 N/O 4 N/O 2 N/O 4 N/O 2 N/O 4 N/O 2 N/O 3 N/O 4 N/O 2 N/O 2 N/C 3 N/O 63 A - 400 V A 4 N/O 4 N/C (1) Low noise version Red catalogue numbers : New products 5 Cat. No 041 23 041 24 040 94 040 67 040 73 040 74 041 47 041 48 040 68 040 69 040 70 040 75 040 76 040 77 040 78 040 79 No of modules 1 2 2 3 2 3 1 2 2 3 3 2 2 3 3 3 Signalling auxiliary 041 85 041 83 040 85 040 85 040 85 040 85 041 85 041 83 040 85 040 85 040 85 040 85 040 85 040 85 040 85 040 85
041 62
041 68
041 85
041 86
041 88
041 89
Pack
Cat.Nos
Pack
Cat.Nos
Compensator module
Used to control 230 V - 50 Hz pulse operated latching relays via illuminated push-buttons without malfunctions Connects to the terminals of the pulse operated latching relay coil Compensation: - 1 compensator module for a total consumption of 3 to 6 mA (example: 6 to 11 illuminated push-buttons consuming 0.55 mA each) - 2 compensators modules for a total consumption of 6 to 9 mA (example: 12 to 17 illuminated pushbuttons with consuming 0.5 mA each) Number
of modules
1 1 10 1 1 1
041 71
12 V 1 N/O 24 V 1 N/O 230 V 1 N/O 2-pole - 16 A - 250 V 24 V 2 N/O 48 V 2 N/O 230 V 2 N/O 4-pole - 16 A - 400 V Can be used for 3-pole assembly 230 V 4 N/O
1 1 1 1 1 1
1
Signalling auxiliary
Fitted on left-hand side of latching relay (equipped or not with control auxiliary) Maximum 2 auxiliaries per latching relay Used to signal the status of the contacts on the associated product Auxiliary changeover switch
I max. Voltage Contact Number of modules
041 85
5A
250 V
N/C + N/O
0.5
Control auxiliary
Fitted on left-hand side of latching relay Maximum 1 control auxiliary per latching relay Compatible with signalling auxiliary Cat.No 041 85 Auxiliary device for centralised control For a centralised control of different latching relays Number from one single point
of modules
1 1 1
041 86 For latching relays 24 V to 48 V 0.5 041 87 For latching relays 230 V 0.5 Auxiliary device for general centralised control 041 88 For simultanous control of different 1 groups of latching relays, already fitted with auxiliary device for centralised control 230 VA Cat.No 041 87 Auxiliary device for maintained contact 041 84 Allows the control of a latching relay via one maintained contact (i.e. time switches) 0.5
s Schemas
Signalling with auxiliary Cat.No 041 85
N L
s Technical characteristics
Power consumption
Control voltage Nominal current Connection Number of modules Holding 12 VA 16 A 1 N/O 1 720 mA 2500 mA 24 VA 16 A 1 N/O 2 N/O 1 330 mA 1200 mA 48 VA 16 A 2 N/O 1 200 mA 700 mA 230 VA 16 A 1 N/O 2 N/O 1 35 mA 130 mA 230 VA 16 A 4 N/O 2 65 mA 250 mA
Cat.No 041 85
Inrush
Centralized control at one point using auxiliary devices Cat.Nos 041 87 and 041 88
N L OFF ON N N ON
Use only non illuminated push-buttons Control via maintained contact using auxiliary device Cat.No 041 84 and time switch
N L
Cat.No 041 84
power contactors
from 16 A to 100 A
041 16
041 23
041 24
041 31
041 47
040 78
Conform to IEC/EN 61095 Space for power supply busbar on top (up to 25 A)
Pack Cat.Nos
Pack
Cat.Nos
041 14
16 A
N/C + N/O
1
1
041 29 25 A
2 N/C
041 16
25 A 4-pole - 400 V
24V
2 N/O
1
1
230V
2 N/O
041 17
25 A
24V
4 N/O
2
5
041 31 041 32
25 A 25 A
230V
4 N/O 4 N/C
2 2
230V
041 33
25 A
230V
2 N/O + 2 N/C
1 1 1 1 1 1
041 23 040 94(1) 040 73(1) 041 24 040 67(1) 040 74(1)
25 A 40 A 63 A 4-pole - 400 V 25 A 40 A 63 A
1 2 2 2 3 3
1 1
040 98 040 99
63 A 100 A
230V
4 N/O 4 N/O
3 6
24V
041 49
25 A
230V
2 N/O
4 1 1 1
1 2 2 2
230V
041 26
16 A
230V
N/C + N/O
1 1
(1)
230V
3 N/O 3 N/O
3 3
10
041 58
25 A
230V
2 N/O
2 1 1 1
230V
2 3 3 3
230V
(1) Handle can be accessed once the blanking plate has been removed
power contactors
from 16 A to 100 A (continued)
power contactors
from 16 A to 100 A
s Technical characteristics
Rated impulsive resistant current (Uimp): 4 kV Mechanical life in cycles of operations: 106 cycles Temperature: - Operation: - 25 C to + 40 C - Storage: - 40 C to +70 C Protection of contactors against short-circuits conforming to IEC EN 61095, conditional short-circuit current Iq = 6 kA MCB or gG fuse, rating: 16 A for 16 A rating 25 A for 25 A rating 40 A for 40 A rating 63 A for 63 A rating 100 A for 100 A rating Control coil consumption
Power contactors 16 A and 25 A Pack Cat.Nos
041 85
041 83
040 85
Auxiliary changeover switch Used to signal the position status of the contacts on the product to which it is connected For 1 module contactors 16 A to 25 A Maximum 2 auxiliary devices per contactor Fitted on left-hand side of contactor
I max. Voltage Changeover switch Number of modules
230 VA 16 - 25 A N/O + N/C 2 N/O 2 N/C 1 20 mA 90 mA 16 - 25 A 2 N/O + 2 N/C 4 N/O 4 N/C 2 20 mA 200 mA
2 300 mA 300 mA
1 6 mA 55 mA
041 85
5A 250 V N/C + N/O For 2 module contactors 25 A Maximum 2 auxiliary devices per contactor Fitted on left-hand side of contactor
I max. Voltage Changeover switch
0.5
Power contactors 40 A, 63 A and 100 A Control voltage Number of modules Nominal current Type of contact 40 and 63 A 2 N/O 24 VA 40 and 63 A 4 N/O 40 and 63 A 2 N/O 2 N/C 2 15 mA 150 mA 230 VA 40 and 63 A 3 N/O 4 N/O 4 N/C 3 30 mA 200 mA 100 A 4 N/O
041 83
5A 250 V N/C + N/O For 40 and 63 A contactors Maximum 1 auxiliary device per contactor Fitted on left-hand side of contactor
I max. Voltage Changeover switch
0.5
Number of modules
2 250 mA 1750 mA
3 270 mA 1500 mA
6 60 mA 460 mA
040 85
5A 250 V N/C + N/O For 100 A contactors Maximum 1 auxiliary device per contactor Fitted on right-hand side of contactor
I max. Voltage Changeover switch
0.5
Recommendations Derating of contactors mounted in modular boxes if the internal temperature is > 40 C
Contactor rating Ie = 16 A Ie = 25 A Ie = 40 A Ie = 63 A 40 C 16 A 25 A 40 A 63 A 50 C 14 A 22 A 36 A 57 A 60 C 12 A 20 A 32 A 50 A 70 C 10 A 18 A 29 A 45 A
Number of modules
035 45
5A
250 V
N/C + N/O
0.5
Install a spacing unit every two contactors (Cat.No 044 40 or 044 41) Max. connection cross-section in mm2
Type of conductor Rigid Flexible Flexible with single ferrule Flexible with double ferrule Ratings 25 A 1 x 6 or 2 x 2.5 1 x 62 or 2 x 2.52 1 x 62 2 x 42
2 2
World Headquarters and International Department 87045 LIMOGES CEDEX FRANCE : + 33 5 55 06 87 87 Fax : + 33 5 55 06 74 55 www.legrandgroup.com