SIMATIC S7 S7-1200 Programmable controller CB 1241 RS485 Specifications

CB 1241 RS485 Specifications


Note To use this CB, your CPU firmware must be V2.0 or higher.

Table 1 Technical data Order number Dimensions Weight Table 2 Technical data Type

General specifications CB 1241 RS485 6ES7 241-1CH30-1XB0 38 x 62 x 21 40 grams Transmitter and receiver CB 1241 RS485 RS485 (2-wire half-duplex) -7 V to +12 V, 1 second, 3 VRMS continuous 2 V min. at RL = 100 1.5 V min. at RL = 54 10K to +5 V on B, RS485 Pin 3 10K to GND on A, RS485 Pin 4 Short Pin TB to Pin T/RB, effective termination impedance is 127 , connects to RS485 Pin 3 Short Pin TA to Pin T/RA, effective termination impedance is 127 , connects to RS485 Pin 4

Common mode voltage range Transmitter differential output voltage Termination and bias Optional termination

Receiver input impedance Receiver threshold/sensitivity Isolation RS485 signal to chassis ground RS485 signal to CPU logic common Cable length, shielded Baud rate Parity Number of stop bits Flow control Wait time

5.4K min. including termination +/- 0.2 V min., 60 mV typical hysteresis 500 VAC, 1 minute

1000 m max. 300 baud, 600 baud, 1.2 kbits, 2.4 kbits, 4.8 kbits, 9.6 kbits (default), 19.2 kbits, 38.4 kbits, 57.6 kbits, 76.8 kbits, 115.2 kbits, No parity (default), even, odd, Mark (parity bit always set to 1), Space (parity bit always set to 0) 1 (default), 2 Not supported 0 to 65535 ms

This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims all liability for the completeness of this document. It shall only be used for the user's own internal purposes. It shall not be passed on to third parties. The complete documentation can be found at: https://www.automation.siemens.com/mdm/default.aspx?DocVersionId=37249085323&Language=en-US&TopicId=35508871691 3/27/2012

SIMATIC S7 S7-1200 Programmable controller CB 1241 RS485 Specifications

Table 3 Technical data

Power supply CB 1241 RS485 1.5 W 50 mA 80 mA

Power loss (dissipation) Current consumption (SM Bus), max. Current consumption (24 VDC) max.

CB 1241 RS485 (6ES7 241-1CH30-1XB0)

Connect "TA" and TB" as shown to terminate the network. (Terminate only the end devices on the RS485 network.) Use shielded twisted pair cable and connect the cable shield to ground.

You terminate only the two ends of the RS485 network. The devices in between the two end devices are not terminated or biased. See the section on "Biasing and terminating an RS485 network connector".

This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims all liability for the completeness of this document. It shall only be used for the user's own internal purposes. It shall not be passed on to third parties. The complete documentation can be found at: https://www.automation.siemens.com/mdm/default.aspx?DocVersionId=37249085323&Language=en-US&TopicId=35508871691 3/27/2012