ACS (Automatic Channel Selection) Long range (up to 80Km); High capacity (48 Mbps) OFDM based air-interface, enabling N-LOS deployments Secured and encrypted traffic
Interfaces: 0,1,2,4 x E1/T1 + 1,2 x Fast Ethernet Ethernet latency < 3msec TDM latency < 8msec
ODU
Radio link
ODU
Ethernet + 4xE1/T1
IDU-E IDU-C
IDU-E IDU-C
Ethernet + 4xE1/T1
Antennas
Integrated and external antennas supported RADWIN supplies several antennas for the different bands Third party external antennas are applicable Typically used antennas :
IDU-C: Carrier form factor Services: 2 x Ethernet + 4 x E1/T1 Power: redundant 110/220VAC, 50/60Hz, -48VDC/-24VDC Compliant with FCC/ETSI/CSA equipment standards Dimensions: 19/1U External alarms (dry contacts)
IDU-C
Air Interface
5.850-5.950 GHz Frequency Bands 5.725-5.850 GHz (FCC/ETSI) 5.470-5.725 GHz (ETSI/IC) 5.150-5.350 GHz (FCC/ETSI) 4.940-4.990 GHz (FCC) 2.500-2.700 GHz (FCC) 2.400-2.4835 GHz (FCC/ETSI) 2.300-2.340 GHz / 2.310-2.485 GHz Channel Bandwidth Transmit Power Duplex Technique Sensitivity (dBm) @ BER < 10e-11 (20MHz) Rate (Mbps) Modulation @ OFDM (Adaptive) 5MHz, 10MHz and 20MHz (5 MHz Resolution) Configurable (max: 18dBm/23dBm) TDD (Time Division Duplex) -87 9 BPSK -84 12 -80 18 -79 24 -73 36 -66 48 -62 54
QPSK
16QAM
64QAM
Ethernet Services
1 or 2 Ethernet interfaces 10/100BaseT with auto-negotiation (IEEE 802.3) Layer 2 Ethernet bridge Self-learning of up to 2047 MAC addresses (IEEE 802.1Q) Support of 1+1 applications (HUB/Bridge selectable mode) Up to 18Mbps symmetrical net throughput VLAN transparent Latency < 3msec Retry mechanism for loss-less connection (Fast ARQ)
Main Features
AES - National Institute of Standards and Technology (NIST) Advanced Encryption Standard (AES). AES128 - Takes uses less than 1% of the link capacity
Adaptive Modulation
Enables the system to change modulations automatically, depending on channel characteristics Enables the user to maximize the Ethernet throughput without degradation in the TDM service quality Supported Modulations and Air Rates:
BPSK (9Mbps) QPSK (12Mbps, 18Mbps) 16QAM (24Mbps, 36Mbps) 64QAM (48Mbps, 54Mbps)
Field System Data Link Information Event Log Site Configuration Active Alarms Performance Monitor Monitor
Description General information about the system Information about the link properties List of recent system events Data about the site parameters List of active alarms Network performance data over defined time periods Detailed event data record
Set Frequency
IDU-2E1-AL
2 E1/T1 2 Ethernet ports 4 input and 4 output dry contact alarms Remote power failure indications Wide DC input range 20 60 VDC
Name Input 1 Input 2 Input 3 Input 4 Output 1 Output 2 Output 3 Output 4 Description User configurable External Alarm User configurable External Alarm User configurable External Alarm User configurable External Alarm Air Link Alarm Equipment Alarm Service Alarm remote end Link Loss due to Power Fail
PoE 8
New IDU for collocated Ethernet applications. 8 Ethernet ports, 8 decoupled ports of ODU, 2 outputs of dry contact alarms. AC input or DC input (- 20 60 )
Link Installation
90 0
Installation Wizard
Installation Process - 1
After antenna alignment use the installation wizard
Installation Process - 2
Link Logical parameters
Installation Process 3
Frequency Selection
Installation Process 4
Service Interface configuration
Installation Process - 5
Rate selection
Installation Process 6
TDM Clocking configuration
Installation Process 7
Configuration Installation completion
VLAN management
To enable VLAN management:
Click Configuration from the main menu Select which site to configure (HQ or Remote site) Select Management Open the VLAN tab Check The Enabled box Enter a VLAN ID Enter a Priority number
Installation Procedure
Installation Procedure
Site Survey Installation : Expected Results: WinLink Link Budget Calculator WinLink-1000 Manager (NMS) Installation on PC Station Cable paving and IDU and ODU connection Power Up (AC/DC adaptor IDU) Antenna alignment (Buzzer) and Mounting Run Installation Wizard via NMS
Site Survey
Between the sites Line Of Sight (Azimuth) Distance (<80 Km) Potential Interference On Site Mounting procedure (Pole or Wall) ODU Grounding ODU-IDU Cable Routing (<100m) IDU Mounting and Power supply
Management Security
Three levels of password protected user authorization:
Read Enables SNMP get command Read/Write - Enables SNMP get and set command Traps Enables SNMP Traps receiving
Version 1.750
New IDU-R (Indoor Unit with Redundancy) that provides a backup wireless link for a E1/T1 wire-line link New ODUs complying with the Indian regulation for 5.8GHz Telnet CLI (Command Line Interface) supported for the entire product portfolio Ethernet throughput control supported for the entire product portfolio
Product name ODU-HE/F24/FCC/EXT and /INT ODU-HE/F49/FCC/EXT ODU-HE/F49/HP/EXT ODU-HE/F54/ETSI/INT ODU-HE/F54/ETSI-LG/EXT ODU-HE/F54/IC/EXT ODU-HE/F54/HP/EXT and /INT ODU-HE/F58/FCC/EXT and /INT WL1000-AIND/F58/FCC/EXT/4T1 ODU-HE/F58/UK/EXT ODU-HE/F59/HP/EXT and /INT
Max Tx power 19dBm 17dBm 23dBm 8dBm 8dBm 15dBm 23dBm 23dBm 23dBm 14dBm 23dBm
Frequency range [GHz] 2.400 2.475 4.940 4.990 5.490 5.710 5.510 5.730 5.490 5.710 5.730 5.845 5.725 5.845 5.725 5.950
5.4GHz
5.8GHz 5.9GHz
WL1000-ODU-HE/F59/HP
WL1000-ODU-HE/F24/FCC/EXT and /INT Supports both 5.8 and 5.9GHz bands Supports Hub Site Synchronization Supports high Tx power up to 23dBm Supports 5, 10, 20MHz channel bandwidth
WL1000-ODU-HE/F59/HP/INT Antenna Type Min Tx Power Max Tx Power Max EIRP Frequency Band Freq. Selection Integrated 22dBi
5725 - 5950 MHz 5.740, 5.760, 5.780, 5.800, 5.820, 5.840, 5.860, 5.880, 5.900, 5.920, 5.940, Manual
WL1000-ODU-HE/F54/ETSI
WL1000-ODU-HE/F54/ETSI/INT and ODU-HE/F54/ETSI-LG/EXT Supports Hub Site Synchronization Supports DFS Supports 20MHz channel bandwidth
WL1000-ODU-HE/F54/ETSI/INT Antenna Type Min Tx Power Max Tx Power Max EIRP Frequency Band Freq. Selection Integrated 22dBi 2 dBm 8 dBm 29 dBm 5.490 5.710 MHz 5.500, 5.520, 5.540, 5.560, 5.580, 5.600, 5.620, 5.640, 5.660, 5.680, 5.700 WL1000-ODU-HE/F54/ETSI-LG/EXT External: 14dBi 4 dBm 15 dBm 28 dBm
WL1000-ODU-HE/F54/HP
WL1000-ODU-HE/F54/HP/EXT and /INT Supports Hub Site Synchronization Supports high Tx power up to 23dBm Supports 5, 10, 20MHz channel bandwidth
WL1000-ODU-HE/F54/HP/INT Antenna Type Min Tx Power Max Tx Power Max EIRP Frequency Band Freq. Selection 44 dBm 5.490 5.710 MHz 5.500, 5.520, 5.540, 5.560, 5.580, 5.600, 5.620, 5.640, 5.660, 5.680, 5.700 Integrated 22dBi 7 dBm 23 dBm 54 dBm WL1000-ODU-HE/F54/HP/EXT External: Flat panel 22 or 28dBi, Dish 32dBi
WL1000-ODU-HE/F54/IC/EXT
Supports Hub Site Synchronization Supports DFS Supports 20MHz channel bandwidth
WL1000-ODU-HE/F54/IC/EXT
Antenna Type Min Tx Power Max Tx Power Max EIRP Frequency Band Freq. Selection
External: Flat panel 22 or 28dBi -3 dBm 15 dBm 30 dBm 5.510 5.730 MHz 5.520, 5.540, 5.560, 5.580, 5.600, 5.620, 5.640, 5.660, 5.680
WL1000-ODU-HE/F49/FCC/EXT
Supports Hub Site Synchronization Supports 20MHz channel bandwidth
WL1000-ODU-HE/F49/FCC/EXT Antenna Type Min Tx Power Max Tx Power Max EIRP Frequency Band Freq. Selection External: Flat panel 21dBi, Dish 27dBi 11 dBm 17 dBm 53 dBm 5.940 5.990 MHz 4.950, 4.970, Manual
WL1000-ODU-HE/F49/HP/EXT
Supports Hub Site Synchronization Supports high Tx power up to 23dBm Supports 5, 10, 20MHz channel bandwidth
WL1000-ODU-HE/F49/HP/EXT Antenna Type Min Tx Power Max Tx Power Max EIRP Frequency Band Freq. Selection External: Flat panel 21dBi, Dish 27dBi 8 dBm 23 dBm 49 dBm 5.940 5.990 MHz 4.950, 4.970, Manual
WL1000-ODU-HE/F24/FCC
WL1000-ODU-HE/F24/FCC/EXT and /INT Supports Hub Site Synchronization Supports 5, 10, 20MHz channel bandwidth
WL1000-ODU-HE/F24/FCC/INT Antenna Type Min Tx Power Max Tx Power Max EIRP Frequency Band Freq. Selection 35 dBm Integrated 16dBi
WL1000-ODU/F58/IDA/EXT Antenna Type Min Tx Power Max Tx Power Max EIRP Frequency Band Freq. Selection
WL1000-ODU/F58/IDA/EXT/PoE
External: Flat panel 18, 22, 28dBi Dish 29, 32dBi 4 dBm 16 dBm 47 dBm 5.825 5.875 MHz 5.840, 5.860, Manual
IDU-R
New IDU that provides backup link for E1/T1 connections Maintains fully operation link at all times In case of failure or primary connection, automatically switches to backup The air-interface can be defined as primary or backup link Operates with all WinLink 1000 outdoor units portfolio Ordering Options: WL1000-IDU-R-E1 and WL1000-IDU-R-T1
Telnet
Supported for all WinLink 1000 products Support local configuration and monitoring of the ODU on site (remote configuration cannot
be performed via Telnet)
Telnet login password = community strings Read allows display only Read/write allows display and set commands
help
VLAN management
New feature in the 1.750 version
Enables separation of user traffic from NMS Traffic All the protocols supported (ICMP, SNMP, TELNET and NTP) Affects all types of management connections (local, network and over the air)
Co-location Deployments
Hub Sync Master The Hub Sync Master (HSM) generates the pulses that synchronize the timing of the Hub Sync Clients (HSC). Hub Sync ClientContinue Transmission In the event that the unit loses synchronization with the Hub Sync Master, the link remains active.. Hub Sync ClientDisable Transmission In the event that the unit loses synchronization with the Hub Sync Master, the link is dropped until the synchronization pulses resume. This setting prevents the unit from causing interference.
Non Sync
Co location interference
Sync
ODU1 Rx
Tx Rx Tx
Tx Rx Tx Rx Rx Tx Rx Rx
Tx Rx Tx Rx Tx Rx
ODU2
Rx Tx
ODU3
Rx
Radio Frame
Channel Bandwidth R-Frame Interval (us) 999 1443 1600 3003 Pattern A B C D 20 MHz TDM EDO TDM Non Optimal Best fit Not Available Non Optimal Best fit Best fit Not Available Not Available 10 MHz EDO TDM Not Available Non Optimal Non Optimal Best fit 5 MHz EDO
Not Available
Pattern A Rx
Tx Rx Tx
Tx Rx Tx Rx Tx Tx Rx Tx Tx Rx Rx Rx
Pattern B Rx
Pattern C Rx
Pattern D Rx
RFD
Thank You!