Renoir II Architectural Wall Box Dimmers


Preset Slide Thin Heat Sink

The Leviton Renoir II line of architectural wall box dimmers supports an unparalleled number of applications using a minimum number of SKUs. Renoir II high performance dimmers support all load types and configurations. Performance, aesthetics, multilocation dimming, color selection, and multi-gang capabilities make Renoir II a highly functional, yet elegant solution for architectural dimming control. FEATURES Universal voltage 120-277V (excludes non-neutral models) Multi-location dimming up to 5-way dimming Remote dimmers and switches Connect up to 5 devices, max 250 on 1 traveler wire Remotes control all connected master dimmers Masters always operate independently Locater indicator illuminates when dimmer is off for easy location in a dark room Non-neutral models for retrofit applications Configurable cut-off level allows user configuration of cut-off point and automatically recalibrates to allow maximum control from cutoff point to full output Smooth-action, linear captive slide control easy, precise adjustment of lighting levels Easy-touch preset switch turns lights ON at last selected brightness level

Clean and stylish appearance Fits standard commercial 2-1/2 deep wall boxes* Decora wallplates coordinate with Levitons extensive line of Decora devices Fins are easily removed for multi-gang applications No visible metal heat sinks, fins, or mounting hardware Solid state triac dimming saves energy when dimming, extends lamp life, and reduces maintenance costs Flicker-free, smooth, and continuous dimming reduces light fluctuations from linevoltage variation and maintains the power delivered to the lamp Power failure memory light is restored to the same levels set prior to the power failure or power interruption Surge protection tested to withstand surges of 6000V, 200A (ANSI/IEEE Std. C62.41-1980) Electrostatic discharge protection protects dimmer against static discharge up to 16,000V Advanced technology engineered heat sinks transfers heat away from essential electrical components for extended product life Square law dimming slider position indicates the perceived light level RFI filtering reduces interference with radio, audio, and video equipment Accessible air gap feature completely disconnects power from the load when lights are off for safety when changing lamps

* Field configurable multi-gang boxes not supported.

Leviton Mfg. Co., Inc. Lighting & Energy Solutions


20497 SW Teton Avenue, Tualatin, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/les
2011 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

Renoir II Architectural Wall Box Dimmers

PRODUCT DATA
MODELS/SUPPORTED LOAD TYPES
Incandescent 120V, 60Hz non-neutral 1-Wire (Dimmed Hot) 120-277VAC, 60Hz (with neutral) 2-Wire (Dimmed Hot + Neutral) Forward Phase Dimmer Square Law Dimming Symmetrical AC Waveform for all load types Incandescent Tungsten Magnetic Low Voltage Forward Phase Control Electronic Low Voltage Transformers Forward Phase Control LED Drivers Forward Phase Control Neon/Cold Cathode Ballasts Minimum load, 15W Electronic Low Voltage 2-Wire (Dimmed Hot + Neutral) 120-277VAC, 60Hz Reverse Phase Dimmer Square Law Dimming Forward or Reverse Phase Control Electronic Low Voltage Transformers Forward or Reverse Phase Control LED Drivers Forward or Reverse Phase Control Neon/Cold Cathode Ballasts Incandescent/Tungsten No minimum load Ballast 0-10V 120-277VAC, 60Hz Linear Dimming Any ballast requiring 0-10V sinking control ex: Leviton Sector, Advance Mark 7*, Universal SuperDim*, Lutron TVE*, Sylvania Quicktronic Powersense* No minimum load Ballast 2-Wire Control (Dimmed Hot + Neutral) 120-277VAC, 60Hz Linear Dimming Forward Phase Control ex: Advance Mark 10*, Sylvania Quicktronic Powersense, Lutron Tu-Wire* No minimum load Ballast 3-Wire Control (Switched Hot + Dimmed Hot + Neutral) 120-277VAC, 60Hz Linear Dimming ex: Lutron Hi-lume*, Lutron Eco-10* No minimum load Switch 120-277VAC, 60Hz Tungsten Loads Resistive Loads Inductive Loads Motor Loads Transformer Loads No minimum load Fan Speed 120-277VAC, 60Hz Any quantity of ceiling paddle fans up to maximum current rating Any fan up to 5A, paddle fan up to 8.3A Patent-pending Super Silent Technology (SST) allows quiet performance with fully variable control No minimum load
*Mark 7 and Mark 10 are registered trademarks of Advance Transformer Company. Tu-Wire, Hi-lume, and Eco-10 are registered trademarks of Lutron Electronics, Inc. TVE is a trademark of Lutron Electronics, Inc. SuperDim is a registered trademark of Universal Lighting Technologies. Quicktronic is a registered trademark of OSRAM Sylvania. Powersense is a trademark of OSRAM Sylvania.

Renoir II Architectural Wall Box Dimmers

DIMENSIONS
A

A Narrow Dimmer 1.720 (43.68mm) 1.720 (43.68mm) 1.720 (43.68mm) 1.720 (43.68mm) 1.720 (43.68mm)

B 5.157 (130.99mm) 5.157 (130.99mm) 5.157 (130.99mm) 5.157 (130.99mm) 5.157 (130.99mm)

C 2.891 (73.4314mm) 4.701 (119.4054mm) 2.891 (73.4314mm) 2.891 (73.4314mm) 2.891 (73.4314mm)

D 0.385 (9.779mm) 0.385 (9.779mm) 0.385 (9.779mm) 0.385 (9.779mm) 0.385 (9.779mm)

E 1.600 (40.64mm) 1.600 (40.64mm) 1.600 (40.64mm) 1.103 (28.1062mm) 1.103 (28.1062mm)

Wide Dimmer Switch Switch Remote

Dimmer Remote

SPECIFICATIONS
Environmental Operating 0 C to 40 C Non-operating 10 C to 85 C Relative humidity, non-condensing 0% to 90% Listings UL/cUL or ETL/cETL listed to UL/CSA Standards (File # E31373 for Dimmers, File # E123566 for Fans) NOM ANSI/IEEE C62.41.2 voltage surges to 6000V & surges to 200A ESD Protection to IEC61000 4-2 Level 4 protects against damage due to static discharge of 16KV or higher FCC Part 15, Class B for radiated and conducted emissions

ORDERING INFORMATION (continues on next page...)


DIMMERS DESCRIPTION Dimmers, Preset Slide Thin Heat Sink CAT. NO.* AWSMT-xxx

* Replace xxx with digits from table below depending on load type.

Load Types Incandescent Non-Neutral (120V Only) -IAW Narrow** -IBW Narrow -ICW Wide -IDW Wide Incandescent -MAW Narrow -MBW Narrow -MCW Wide -MDW Wide Ballast: 0-10V -7DW Narrow Ballast: 2-Wire Control -XAW Narrow -XBW Narrow -XCW Wide -XDW Wide Ballast: 3-Wire Control -HAW Narrow -HBW Narrow -HCW Narrow -HDW Narrow Electronic Low Voltage -EAW Wide -EBW Wide Current* 5A 8-1/3A 12.5A 16A

Ratings VA @ 120VAC* 600 1,000 1,500 2,000 VA @ 230VAC* 1,150 1,917 2,875 3,680 VA @ 277VAC* 1,385 2,308 3,463 4,432

*Ganged dimmers may require de-rating. Please reference www.leviton.com/RenoirII for additional information. **Narrow/Wide indicator indicates width of the heat sink. Reference dimensions section for sizes.

FAN SPEED CONTROLS Rated for control of any number of ceiling style paddle fans up to ratings below Rated for control of any motor up to 5A DESCRIPTION Fan Speed Controls, Preset Slide Thin Heat Sink CAT. NO.* AWSMT-xxx Fan Speed Controls -QAW Narrow -QBW Narrow Current* 5A 8-1/3A VA @ 120VAC* 600 1,000

Ratings VA @ 230VAC* 1,150 1,917 VA @ 277VAC* 1,385 2,308

* Replace xxx with digits from table below depending on load type.

*Ganged dimmers may require de-rating. Please reference www.leviton.com/RenoirII for additional information. **Narrow/Wide indicator indicates width of the heat sink. Reference dimensions section for sizes.

SWITCHES DESCRIPTION Switch Controls, Preset Slide Thin Heat Sink CAT. NO.* AWWMT-0DW Switches VA Horsepower Current* 15A VA @ 120VAC* 1,800 1/2 HP

Ratings VA @ 230VAC* 3,450 1.5HP VA @ 277VAC* 4,150 1.5HP

*All switches use Narrow heat sink.

Leviton Mfg. Co., Inc. Lighting Management Systems


20497 SW Teton Avenue, Tualatin, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/lms
2009 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

Renoir II Architectural Wall Box Dimmers

PRODUCT DATA
ORDERING INFORMATION continued...
REMOTES DESCRIPTION Remotes, Slide Control Thin Heat Sink Remotes, Switch Control Thin Heat Sink CAT. NO.* AWSRT-00W AWWRT-00W

COLOR CHANGE KITS DESCRIPTION Color Change Kits, Preset Slide Thin Heat Sink CAT. NO.* AWyCT-00x

* Replace y and x with digits from options below depending on control type and color.

y=Control Type, replace y with any of the following: S=Slide Control, W=Switch -00x=Color, replace x with any of the following: A=Almond, E=Black, G=Gray, I=Ivory, T=Light Almond, W=White, C=Custom/Field Painted

WALL PLATES Each device is supplied with a white single gang plate. For purchase of replacement plates or plates in an alternate color, please consult the chart below. For custom plates, please note required 4-6 week lead time.

Renoir II Architectural Wall Box Dimmers

DESCRIPTION Wall Plates for Renoir II Architectural Wall Box Dimmers

CAT. NO.* AWP0y-nwc

* Replace y and n, w, c with digits from options below depending on fins, number of Narrow or Wide dimmers, and color.

y=Indicates whether fins are to be left on or removed. Replace with the following: F=All fins remain on, 0=Fins to be removed when possible (allows for narrowest possible installation) n=Number of Narrow dimmers, 0-6 supported* w=Number of Wide dimmers, 0-4 supported* c=Color, replace with any of the following: A=Almond, E=Black, G=Gray, I=Ivory, T=Light Almond, W=White, C=Custom/Field Painted, K=24K Gold, B=Satin Brass, L=Brushed Stainless Steel, R=Antique Bronze
*Ganged dimmers may require de-rating. Some configurations require custom wall plates that are built to order and not available in metal finishes. Please reference www.leviton.com/RenoirII or consult with customer service for additional information.

CAUTION ON RETROFITS: When retrofitting dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start sockets in order to allow proper dimmer operation and prevent damage to the dimming ballast. Refer to the instructions provided with the ballast. Leviton sockets for T8 lamps which fit many common applications can be purchased with P/N #13661.

LEVITON SPECIFICATION SUBMITTAL JOB NAME: JOB NUMBER: CATALOG NUMBERS:

Leviton Manufacturing Co., Inc. Lighting & Energy Solutions

20497 SW Teton Avenue, Tualatin, OR 97062 Telephone: 1-800-736-6682 FAX: 503-404-5594 Tech Line (6:00AM-4:00PM P.S.T. Monday-Friday): 1-800-959-6004

Leviton Manufacturing of Canada, Ltd. Leviton S. de R.L. de C.V.

165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9 Telephone: 1-800-469-7890 FAX: 1-800-563-1853 Lago Tana 43, Mexico DF, Mexico CP 11290 Tel. (+52) 55-5082-1040 FAX: (+52) 5386-1797 www.leviton.com.mx

Visit our Website at: www.leviton.com/les


2011 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice. G-8279A/K11-tb REV NOV 11

Cat. Nos. AWRMG, AWSMG, AWSMT, AWWMG, AWWMT


Environmental Conditions: 0-40 C, 0-90% non-condensing humidity. Input Power Rating 110-277VAC, 60Hz only (incandescent non-neutral model is 120V input only)
PK-93824-10-00-2A-X2

RENOIR II

INSTALLATION WARNINGS AND CAUTIONS:


TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS. IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN. DO NOT GANG VERTICALLY. ONLY INSTALL FOR THE ALLOWED LOAD TYPES (SEE FIGURE 5). INSTALLATION FOR ANY OTHER LOAD TYPE WILL VOID WARRANTY AND POSSIBLY CAUSE DAMAGE TO THIS DEVICE AND/OR CONNECTED EQUIPMENT. USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY.

Installation Instructions: 1. WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN OFF POWER AT CIRCUIT

De-ratings:

Features and Operation:


Turn Dimmer ON or OFF Pressing the switch will turn the dimmer ON if the dimmer is OFF. If the dimmer is ON, pressing the switch will turn the dimmer OFF. Set Dimmer Level Adjust the knob or slider to set the desired output level. When the dimmer turns ON, the dimmer always turns ON to the level set by the slider or knob. Set Cutoff Level The cutoff level is the lowest voltage the dimmer will output before shutting off. To set the cutoff level, adjust the knob or slider to the cutoff level you desire, then push and hold the button for 5 seconds. The dimmer will turn OFF and then back ON again indicating that the new cutoff level has been set. To reset the cutoff level to 0, lower the slider all the way down, then push and hold the button for 5 seconds. If your load type is flickering , not turning on, or suffering from any other erratic behavior at the minimum setting, raising the cutoff level may eliminate the problem. Preset Operation While dimmer is off, set level of dimmer. Then press button. The dimmer will turn on at the set level. Power Restore Upon restoration of power, the dimmer turns ON to the state it was in at the time of power loss. 5-Way Operation Link together 2, 3, 4, or 5 dimmers for multi-way dimming. LED Locator At the bottom of the switch is an LED locator. This locator illuminates when the dimmer is OFF so you can find the dimmer in the dark. Remote Control If you are using a remote, the operation at the remote is identical to the operation at the master. A slight reaction delay may be noticed if operating level changes very quickly. Service Switch Some units have a service switch which must be used to disconnect the load when replacing lamps. The breaker should be disconnected when performing any luminaire, ballast, or other circuit service other than lamp replacement.
Load Disconnected Load Connected Load Disconnected Load Connected Service Switch

BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING! 2. Remove existing wall plate and switch, if applicable. 3. Remove 5/8 (1.6 cm) of insulation from each circuit conductor. Make sure the ends of wires are straight. 4. Connect wires per WIRING DIAGRAM on device as follows: Twist strands of each lead tightly together and, with circuit conductors, push firmly into appropriate wire connector. Screw connectors on clockwise making sure no bare conductors show below the wire connectors. Secure each connector with electrical tape. 5. Installation may now be completed by carefully positioning all wires to provide room in outlet box for dimmer. Mount dimmer into box with mounting screws supplied. Snap faceplate into place. 6. Install device control push button and control assembly (see below). 7. Restore power at circuit breaker or fuse. Installation is complete. 8. Test Dimmer operation.
Align flats when installing knob Center tab in opening

When fins are broken, some dimmer models must be de-rated. Reference Figure 5 to determine the dimmer ratings when 0, 1, or 2 fins are removed.

Multi-Way Dimming:
The Renoir II product line supports up to 5-way dimming. Any combination of Dimmers, Switches, or Remotes are supported with a MAXIMUM OF 5 DEVICES. Total run length from end to end is MAXIMUM 250 FEET. Remotes require Uncontrolled Hot, Neutral, & Ground for proper operation. One traveler wire is to run in between all masters and remotes. Remotes draw 15mA power (ea) from the Dimmer to which they are connected. NOTE: Remote Hot/Neutral should ideally be fed from the same circuit as the Master. If this is not possible, ensure that the master and remote are both fed from the same phase. Load after Remote Dimmer/Switch and Master Dimmer/Switch
Hot Hot Dimmed Hot Neutral Ground

Back Box Size & Joiner Bars:

To determine the required back-box size in multi-gang installations, reference Figure 1. In applications where the dimmers do not line up with back box device mounting holes, use joiner bars to join the dimmers together. Reference Figures 1 & 3.

Figure 2 - Fin Removal

Break off these fins

Neutral

Ground

Neutral

Fin break off points Back view of dimmers shown Break off these fins

Ground Traveler

LOAD

Remote Dimmer/Switch

Master Dimmer/Switch

Load in between Master Dimmer/Switch and Remote Dimmer/Switch


Hot Neutral

Ground Traveler Hot Dimmed Hot Neutral Ground

Rotary dimmer

Slide dimmer

Neutral

Ground

LOAD

Multi-Gang Installations:

Service Switch Rotate far left for OFF, rotate far right for ON

A multi-ganged installation exists when multiple devices are installed in the same back box. In multi-gang installations, the following may be required: 1. Dimmer location 2. Dimmer de-rating 3. Fin removal 4. Back box size 5. Use of joiner bars for adjacent dimmers. 6. Narrow dimmers must always be installed in between wide dimmers. NOTE: TEST FIT DIMMER INSTALLATION WITH THE WALL PLATE PRIOR TO BREAKING FINS OR INSTALLING DIMMERS TO ENSURE YOU UNDERSTAND ALL REQUIREMENTS.

DO NOT Break off these fins

Master Dimmer/Switch

Remote Dimmer/Switch

Figure 3 - Joiner Bar

Multiple Remote Dimmer/Switches


Dimmed Hot Neutral Ground

Back Box Size Chart Figure 1

LOAD

NOTE: Basic configurations shown. For additional multi-gang configurations, see Figure 5A. Basic Configurations Number & Type of NARROW 0 Backbox - # Gangs Wallplate Part # Backbox - # Gangs 1 Wallplate Part # Backbox - # Gangs 2 Device Configuration Wallplate Part # 3 Backbox - # Gangs Wallplate Part # Device Configuration Device Configuration N AWP0F-10x 2 N*+*N AWP00-20x N+N+N AWP00-30x 4** 1 Device Configuration 0 1 W AWP0F-01x W+N AWP0F-11x 4 W+N*+*N AWP00-21x W+N+N+N AWP00-31x 6** 3 1 Number & Type of WIDE 2 4 3 W+W+W AWP0F-03x W+W+N+W AWP0F-13x 8 W*+*W+N*+*N+W AWP00-23x W*+*W+N*+N*+*N+W AWP00-33x
Wide/Narrow Wide/Wide
Hot Neutral

Narrow/Narrow

Hot

Rotary Dimmer

Slide Dimmer

W+W AWP0F-02x W+N+W AWP0F-12x 6 W+N*+*N+W AWP00-22x W+N*+N*+*N+W AWP00-32x 7 5 or 6

6**

Neutral

Hot

Ground

Neutral

Hot

Ground

Neutral

Hot

Traveler

Ground

Neutral

Hot

Traveler

Ground

Neutral

Traveler

Ground

Traveler

Installation Requirements:
These devices are designed for installation into a 2" x 3" (5.08 cm x 7.62 cm) single gang or multi-gang device back box. 2-1/2" (6.35 cm) or deeper back boxes are required. These devices are not designed for a multi-gang field configured box. In some installations where conduit entry is from the side, or, in multi-gang installations where nipples between two adjacent boxes are used, deeper back boxes may be necessary. Test fit installation prior to rough-in. Installation of multiple devices into a single box may require de-rating and other specific installation provisions. Reference Multi-Gang Installations for more details. As dimmers vent top/bottom, dimmers should not be installed vertically (one over the other). To avoid flickering, flashing, or lights on one dimmer adjusting when another dimmers level is changed, do not share neutrals. Run separate neutrals for each load circuit back to the dimmer. Load
White Neutral (White)

Joiner Bar Joiner Bar

Master Dimmer/Switch

Remote Dimmer/Switch

Remote Dimmer/Switch

Remote Dimmer/Switch

Remote Dimmer/Switch

Maximum 5 Devices, Dimmers or Remotes Maximum 250 feet

Multiple Dimmer/Switches and Remote Dimmer/Switches


Dimmed Hot Neutral Ground

LOAD

Dimmed Hot Neutral Ground

LOAD

Hot (Black)

Black

Run a separate neutral wire


for each dimming circuit

Hot (Black) Neutral (White)

Black

Load

X DO NOT share
neutral wires White

1. Find the cells that correspond to your application by identifying the row with the number of wide heatsink dimmers you have, and the columns that correspond to the number of narrow heat sink dimmers you have. In the cell youll find the following: 2. The number indicates the number of Gangs required. 3. The letters under the number indicate the order dimmers should be installed, N=narrow, W=wide. 4. - W* = right fin break-off on wide dimmer, N* = right fin break-off on narrow dimmer. - *W = left fin break-off on wide dimmer, *N = left fin break-off on narrow dimmer. - *W* = fin break-off on both sides of wide dimmer, *N* = fin break-off on both sides of narrow dimmer. 5. '** indicates that use of jumper bars is required. Jumper bars can be found in the kit with the faceplate. 6. Replace 'x' in the faceplate part number with the desired color: W=White, I=Ivory, A=Almond, T=Light Almond, E=Black, G=Gray, K=24K Gold, L=Satin Stainless, R=Antique Bronze, B=Brushed Brass. NOTE: Metal finishes are not available on custom face plates.

Hot

Figure 4 - Second Single Gang Device Box


Four-gang wallbox Single-gang wallbox

Ground

Neutral

Hot

Ground

Neutral

Hot

Traveler

Ground

Neutral

Hot

Traveler

Ground

Neutral

Traveler

Ground

Traveler

Master Dimmer/Switch

Remote Dimmer/Switch

Dimmer/Switch

Remote Dimmer/Switch

Remote Dimmer/Switch

Fin Removal:

3-1/2" deep back box is required

Maximum 5 Devices, Dimmers or Remotes Maximum 250 feet

When it is desired to install dimmers in as small a space as possible, all inside fins of like sized, adjacent dimmers can be broken off. Figures 1 & 2 show how to break off fins and the specific order in which multiple dimmers must be installed in multi-gang installations.

3/4" space (use chase nipple)

Figure 5 - Model, Voltage, Allowed Loads, Current and De-rating Charts INCANDESCENT DIMMER - 110-277VAC/VCA, 60Hz
Use only for permanently installed luminaire of load type: Incandescent, Tungsten, Inductive Transformer (ex: magnetic low voltage), LED fixtures with drivers with incandescent control input. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a fluorescent lighting luminaire. INCANDESCENT AWRMG-MA_ AWSMG-MA_ AWSMT-MA_ AWRMG-MB_ AWSMG-MB_ Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V 0 FINS REMOVED 1 FIN REMOVED 5.0 600 1150 1385 6.5 780 1495 1801 2 FINS REMOVED

INCANDESCENT NON-NEUTRAL DIMMER - 110-277VAC/VCA, 60HZ


Use only for permanently installed luminaire of load type: Incandescent, Tungsten, Inductive Transformer (ex: magnetic low voltage), LED fixtures with drivers with incandescent control input. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a fluorescent lighting luminaire. INCANDESCENT NON-NEUTRAL AWRMG-IA_ AWSMG-IA_ AWSMT-IA_ 5.3 636 AWRMG-IB_ AWSMG-IB_ Amps VA @ 120V Amps VA @ 120V Amps VA @ 120V Amps VA @ 120V Amps VA @ 120V Amps VA @ 120V Amps VA @ 120V 0 FINS REMOVED 1 FIN REMOVED 5.0 600 6.5 780 5.3 636 12.3 1476 12.3 1476 5.5 660 8.7 1044 11.1 1332 2 FINS REMOVED

FLUORESCENT - 2 WIRE PHASE CONTROL - 120-277VAC/VCA, 60HZ


Use only for control of electronic ballasted luminaires. Intended for Advance Mark 10, Lutron Tu-Wire, or Sylvania Quicktronic Power Sense ballasts. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a transformer supplied appliance. FLUORESCENT 2 WIRE PHASE CONTROL Amps AWRMG-XA_ VA @ 120V AWSMG-XA_ VA @ 230V AWSMT-XA_ VA @ 277V Amps VA @ 120V AWRMG-XB_ VA @ 230V AWSMG-XB_ VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V 0 FINS REMOVED 1 FIN REMOVED 5.0 600 1150 1385 6.5 780 1495 1801 2 FINS REMOVED

ELECTRONIC LOW VOLTAGE - 120-277VAC/VCA, 60HZ


Use only for permanently installed luminaire of load type: Incandescent, Tungsten, or Electronic Transformer. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a fluorescent lighting luminaire. ELECTRONIC LOW VOLTAGE AWRMG-EA_ AWSMG-EA_ AWSMT-EA_ Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V 0 FINS REMOVED 1 FIN REMOVED 5.0 600 1150 1385 2 FINS REMOVED

8.3 1000 1917 2308

AWRMG-MC_ AWSMG-MC_

AWRMG-MD_ AWSMG-MD_

AWSMT-MB_

VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V

PR
16.0 1920 3680 4432 8.3 1000 1917 2308 12.5 1500 2875 3463 16.0 1920 3680 4432 2875 3463

12.5 1500

13.5 1620 3105 3740 7.0 840 1610 1939 10.2 1224 2346 2825 13.0 1560 2990 3601

LIM E
2829 3407 12.3 1476 2829 3407 5.5 660 1219 1468 12.3 1476 1265 1524 8.7 1044 2001 2410 11.1 1332 2553 3075

AWRMG-IC_ AWSMG-IC_ AWRMG-ID_ AWSMG-ID_

AWSMT-IB_

AWSMT-IC_ AWSMT-ID_

RY INA
8.3 1000 16.0 1920 8.3 1000 12.5 1500 16.0 1920 12.5 1500 0 FINS REMOVED

8.3 1000 1917 2308

13.5 1620 7.0 840 10.2 1224 13.0 1560

AWRMG-XC_ AWSMG-XC_

12.5 1500 2875 3463

1219 1468 12.3 1476 2829 3407 12.3 1476 2829 3407 5.5 660

5.3 636

AWRMG-EB_ AWSMG-EB_

AWSMT-EB_

8.3 1000 1917 2308

8.3 1000 1917 2308

1725 2078

7.5 900

8.2 984 1886 2271 6.8 816 1564 1884

AWRMG-XD_ AWSMG-XD_

FLUORESCENT - 0-10VDC SINKING CONTROL - 120-277VAC/VCA, 60HZ


Use only for permanently installed electronic ballasted luminaire of fluorescent, HID, or LED load type with driver/ballast setup for 0-10Vdc sinking control. Dimmer will sink maximum 75mA. Intended for the control of Advance Mark 7, Universal Sumper Dim, Lutron TVE, Leviton Sector, or Sylvania Quicktronic Powersense ballast. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a transformer supplied appliance. FLUORESCENT 0-10VDC SINKING CONTROL Amps AWRMG-7D_ VA @ 120V AWRMT-7D_ AWSMG-7D_ VA @ 230V AWSMT-7D_ VA @ 277V 1 FIN REMOVED 16.0 1920 3680 4432 2 FINS REMOVED AWSMT-XB_

AWSMT-MC_

AWSMT-XC_

Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V Amps VA @ 120V VA @ 230V VA @ 277V

16.0 1920 3680 4432 8.3 1000 1917 2308 12.5 1500

13.5 1620 3105 3740 7.0 840

FAN SPEED CONTROLS, FULL VARIABLE, FULL QUIET - 120-277VAC/VCA, 60HZ


For use with any fan, up to 5A. For use with any quantity of ceiling paddle fans up to maximum current rating. FAN SPEED CONTROLS FULL VARIABLE, FULL QUIET Amps AWRMG-QA_ VA @ 120V AWSMG-QA_ VA @ 230V AWSMT-QA_ VA @ 277V Amps VA @ 120V AWRMG-QB_ AWSMG-QB_ VA @ 230V VA @ 277V Amps VA @ 120V AWSMT-QB_ VA @ 230V VA @ 277V 0 FINS REMOVED 1 FIN REMOVED 5.0 600 1150 1385 6.5 780 1495 1801 7.0 840 1610 1939 2 FINS REMOVED

AWSMT-MD_

AWSMT-XD_

2875 3463 16.0 1920 3680 4432

1610 1939 10.2 1224 2346 2825 13.0 1560 2990 3601

1265 1524 8.7 1044 2001 2410 11.1 1332 2553 3075

8.3 1000 1917 2308 8.3 1000 1917 2308

1219 1468 5.5 660 1265 1524

5.3 636

FLUORESCENT - 3 WIRE PHASE CONTROL - 120-277VAC/VCA, 60HZ


Use only for control of electronic ballasted luminaires. Intended for Lutron Eco-10, Hi-Lume, or Hi-Lume 3D Fluorescent Ballasts. CAUTION: To reduce risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, or a transformer supplied appliance. FLUORESCENT 0, 1 or 2 FINS 3 WIRE PHASE CONTROL REMOVED Amps 5.0 AWRMG-HA_ VA @ 120V 600 AWSMG-HA_ 1150 VA @ 230V AWSMT-HA_ 1385 VA @ 277V Amps 8.3 AWRMG-HB_ VA @ 120V 1000 AWSMG-HB_ 1917 AWSMT-HB_ VA @ 230V 2308 VA @ 277V Amps 12.5 AWRMG-HC_ VA @ 120V 1500 AWSMG-HC_ 2875 AWSMT-HC_ VA @ 230V VA @ 277V 3463 Amps 16.0 AWRMG-HD_ VA @ 120V 1920 AWSMG-HD_ 3680 AWSMT-HD_ VA @ 230V VA @ 277V 4432

Figure 5A
Remove Fins Fins Left On Remove Fins Fins Left On Remove Fins Fins Left On Remove Fins Fins Left On

Additional Configurations Backbox - # Gangs Wallplate Part # Device Configuration Backbox - # Gangs Wallplate Part # Backbox - # Gangs Wallplate Part # Backbox - # Gangs Wallplate Part # Backbox - # Gangs Wallplate Part # Device Configuration Backbox - # Gangs Wallplate Part # Backbox - # Gangs Wallplate Part # Backbox - # Gangs Wallplate Part # Device Configuration Device Configuration Device Configuration Device Configuration

0 N/A

1 W AWP0F-01x not supported 1

Number & Type of WIDE 2 3 4 6**

4 W+W+W+W AWP0F-04x W*+*W*+*W*+*W 7 9

Figure 5A - continued
Remove Fins Fins Left On Remove Fins Fins Left On Remove Fins Fins Left On

Additional Configurations Backbox - # Gangs Wallplate Part # Device Configuration Backbox - # Gangs Wallplate Part # Backbox - # Gangs Wallplate Part # Backbox - # Gangs Wallplate Part # Backbox - # Gangs Wallplate Part # Device Configuration Backbox - # Gangs Wallplate Part # Device Configuration Device Configuration

0 N+N+N+N AWP0F-40x N*+*N*+*N*+*N AWP00-40x N+N+N+N+N AWP0F-50x N*+*N*+*N*+*N*+*N AWP00-50x N+N+N+N+N+N AWP0F-60x 6 7+1** 5 7** 4 4+1**

1 W+N+N+N+N AWP0F-41x W+N*+*N*+*N*+*N AWP00-41x W+N+N+N+N+N AWP0F-51x W+N*+*N*+*N*+*N*+*N AWP00-51x W+N+N+N+N+N+N AWP0F-61x 8 9+1** or 11 7 9** 6 6+1** or 8

Number & Type of WIDE

3 W+W+N+N+N+N+W AWP0F-43x 10 13

4 W+W+N+N+N+N+W+W AWP0F-44x W*+*W+N*+*N*+*N*+*N+W*+*W AWP00-44x W+W+N+N+N+N+N+W+W AWP0F-54x W*+*W+N*+*N*+*N*+*N+*N+W*+*W AWP00-54x W+W+N+N+N+N+N+N+W+W AWP0F-64x 14 18 13 17 12 15

W+W AWP0F-02x W*+*W AWP00-02x 5 or 6 3

W+W+W AWP0F-03x W*+*W*+*W AWP00-03x W+W+N+W AWP0F-13x W*+*W+N+W AWP00-13x 7 8 5

W+N+N+N+N+W AWP0F-42x W+N*+*N*+*N*+*N+W AWP00-42x W+N+N+N+N+N+W AWP0F-52x W+N*+*N*+*N*+*N+*N+W AWP00-52x W+N+N+N+N+N+N+W AWP0F-62x 10 11+1** or 13 9 11** or 12 8

8+1** or 10

Device Configuration 1

Device Configuration

W*+*W+N*+*N*+*N*+*N+W AWP00-43x W+W+N+N+N+N+N+W AWP0F-53x W*+*W+N*+*N*+*N*+*N+*N+W AWP00-53x W+W+N+N+N+N+N+N+W AWP0F-63x 12 16 11 14

N AWP0F-10x

W+N AWP0F-11x not supported

W+N+W AWP0F-12x

W+W+N+W+W AWP0F-14x W*+*W+N+W*+*W AWP00-14x W+W+N+N+W+W AWP0F-24x W*+*W+N*+*N+W*+*W AWP00-24x W+W+N+N+N+W+W AWP0F-34x 11 14 10 12 9

11

Number & Type of NARROW

Number & Type of NARROW

AWP00-04x

N+N AWP0F-20x N*+*N AWP00-20x N+N+N AWP0F-30x 3 4** 2

1+1

3+1, or 5 W+N+N 4 AWP0F-21x W+N*+*N AWP00-21x W+N+N+N AWP0F-31x 5 6**

W+N+N+W AWP0F-22x W+N*+*N+W AWP00-22x W+N+N+N+W AWP0F-32x 7 9 6

5+1** or 7

W+W+N+N+W AWP0F-23x W*+*W+N*+*N+W AWP00-23x W+W+N+N+N+W AWP0F-33x 9 11 8

10

Device Configuration

Device Configuration N*+*N*+*N*+*N*+*N*+*N W+N*+*N*+*N*+*N*+*N*+*N W+N*+*N*+*N*+*N*+*N*+*N+W W*+*W+N*+*N*+*N*+*N*+*N*+*N+W W*+*W+N*+*N*+*N*+*N*+*N*+*N+W*+*W AWP00-60x AWP00-61x AWP00-62x AWP00-63x AWP00-64x

SWITCHES - 120-277VAC/VCA, 60HZ

Use only for resistive, incandescent, inductive, ballast or motor load. SWITCHES Amps HP @ 120V HP @ 230V AWWMG-0D_ HP @ 277V AWWMT-0D_ FLA VA @ 120V VA @ 230V VA @ 277V 0, 1 or 2 FINS REMOVED 15.0 1HP 1.5HP 1.5HP 12.0 1800 3450 4150 3

N*+*N*+*N W+N*+*N*+*N W+N*+*N*+*N+W W*+*W+N*+*N*+*N+W W*+*W+N*+*N*+*N+W+W AWP0F-30x AWP00-31x AWP00-32x AWP00-33x AWP00-33x

1. W* = right fin break-off on wide dimmer, N* = right fin break-off on narrow dimmer. *W = left fin break-off on wide dimmer, *N = left fin break-off on narrow dimmer. *W* = fin break-off on both sides of wide dimmer, *N* = fin break-off on both sides of narrow dimmer. 2. '** Indicates that use of jumper bars is required. Jumper bars can be found in the kit with the faceplate. 3. '+1 indicates that in addition to the multi-device box, a second 1 device box shall be installed 3/4" apart from the first. A 3/4" chase nipple shall be used between the two boxes (ref. Figure 4). 4. Replace 'x' in the wall plate part number with the desired color: W=White, I=Ivory, A=Almond, T=Light Almond, E=Black, G=Gray, K=24K Gold, L=Satin Stainless, R=Antique Bronze, B=Brushed Brass. NOTE: Metal finishes are not available on custom face plates.

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Levitons only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. 2009 Leviton Mfg. Co., Inc. For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com PK-93824-10-00-2A-X2