PowerWorx Select Series

Circuit Breaker

Description
The pre-configured Circuit Breaker Panel offers both continuous power supply and reliable power protection for network operators. Its short-delay circuit breakers of 10 Amps (two) and 5 Amps (five) per bus allow flexible connection of active standard equipment. High-brilliance LEDs allow technicians to quickly identify input power failures or tripped breakers. A front-based alarm reset push button allows the alarm to be switched off for effective fault diagnostics.

Application
Nearly all active equipment for voice, video and data services can be fed by PowerWorx Select Series Circuit Breaker Panel, such as optical transmitters/receivers, CTMS, DSLAM, media converters, modulators or others. Due to its dual bus layout it can be used to support active equipment redundantly by using two independent power sources such as rectifiers or battery banks, increasing reliability of the overall system significantly.

Technical DaTa
www.adckrone.com Technical Assistance Centre: +32 2 712 6542 euro.tac@adckrone.com Freephone (UK only): 0800 960236

Product Specifications
ELECTRICAL CHARACTERISTICS
Breaker type: Actuator: Trip: Panel capacity: Operating voltage: Power dissipation: Fail alarm indicators: Alarm contact connection: Alarm contact relay: Input Power (feed connection): Output Power (feed connection): Post size: Distance between barrier walls: Grounding: Hydraulic magnetic circuit breaker, 2 x 10 A and 5 x 5 A Rocker with finger guard (breaker amperage shown on faceplate) Series trip with manual reset 100 Amps maximum per bus (200 Amps total, dual bus configuration) -24 VDC (-21 to -31 VDC tolerance) or -48VDC (-42 to -56 VDC tolerance) 80 watts maximum Red LED indicates tripped breaker. Green LED indicates power on. Alarm output contacts provided for audible, visual, and remote alarms. Screw down barrier terminal strip 1 Amp maximum Two-hole compression lug (stud type) accepts range of wire up to 2 AWG. Product ships with two 2-hole lugs (accepting 2 AWG wire) per power bus Screw-down barrier terminal strip accepts range of bare wire for 8-16 AWG 8-32 9.60 mm Two-post grounding accepts range of wire up to 10 AWG. Grounding can be done with two #10 wires and two #10 ring terminals or use larger AWG sizes across both studs -40C to +85C -40C to +65C

TEMPERATURE CHARACTERISTICS
Storage temperature: Operating temperature:

ENVIRONMENTAL CHARACTERISTICS
Operating humidity: Operating altitude: Standards: Warranty: 0% to 95%, non-condensing Up to 3.96 km Meets UL, Telcordia (Bellcore), NEC 2002, CSA, NEBS Level 3 and CE 5 years 4.44 cm x 43.48 cm x 25.4 cm 4.9 kg 19 or 23 (48.3 or 58.4 cm) recess-mountable mounting brackets (WECO/EIA rack-mountable) Cold-rolled 16 gauge steel. Protective input and output covers provided with all panels Powder-coat putty white

Technical DaTa

MECHANICAL CHARACTERISTICS
Dimensions (HxWxD): Weight: Rack Mounting Width: Housing material: Housing finish:

Ordering Information
Description PowerWorx Select Series Circuit Breaker

Catalog Number EWX-451VVNNNNNSSP

Web Site: www.adckrone.com/en


EMEA Office: ADC GmbH, Beeskowdamm 3-11, 14167 Berlin, Germany Phone: +49 30 8453-1818 Fax: +49 30 8453-1703 For a listing of all ADC KRONEs global sales office locations, please refer to our web site.
Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC KRONE reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting ADC GmbH headquarters in Berlin. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. 201112BE Sept. 09 Original 2009 ADC Telecommunications Inc. All Rights Reserved