eff=(1-T2/T1)
T1
T2
Rankine cycle
P2 T Pcr P1
00
56 2
00
00
00
SUPER CRITICAL BOILER CYCLE WITH SH, RH & Regeneration of SIPAT 3 x 660 MW
Steam flow Steam temp Steam Pres RH pre RH Temp Feed water Temp
00
00 0
ENTROPY
Natural Circulation
Controlled Circulation
Types of Circulation
DRUM
CC Pump
Bank II
Bank I
Economizer
H.R .H
M.S
C.R.H
FROM F.R.S BOTTOM RNG HDR& Z-PANEL 1 ST PASS W.W O/L HDRS 2 ND PASS UPPER C-HDR LTSH I/L HEADER D.P.I/L HEADER S.H. HEADER 2 ND PASS ROOF O/L HDR(REAR 1 ST PASS W.W
ROOF I/L HEADER 2nd PASS LOWER C-HDRS LTSH O/L HEADER D.P.O/L HEADER R.H.HEADER
ECONOMISER
Boiler Parameters
Raichur 210MW Steam flow at SHO Steam pressure at SHO t/h 680 540 597.2 540 247.5 Bellary 500MW 1625 178 540 1389.76 540 254.6 Ramagundam 500 MW 1675 178 540 1387.2 540 253.7
kg/Sq.Cm(g) 155
Types of boilers
Drum type
Once-through type
Steam generation takes place in furnace water walls Fixed evaporation end point - the drum Steam -water separation takes place in the drum Separated water mixed with incoming feed water
500 MW
Data Sheet
T 4 Temperature
1-2 Feed Water Pumping Process 2-3 Heat addition in the Feed Water Heaters & Boiler 3-4 Expansion in HP Turbine 4-5 Reheating in Boiler 5-6 Expansion in IP & LP Turbine 1 Entropy 6 S 6-1 Heat rejection in Condenser
Supercritical Boilers
Supercritical pressure boiler has no drum and heat absorbing surface being, in effect, one continuous tube, in which the water & steam generated in the furnace water walls passes through only once hence called Once through Supercritical pressure boilers The water in boiler is pressurized by Boiler Feed Pump, sensible heat is added in feed heaters, economizer and furnace tubes, until water attains saturation temperature and flashes instantaneously to dry saturated steam and super heating commences.
The Concept
The mass flow rate thru all heat transfer circuits from Eco. inlet to SH outlet is kept same except at low loads wherein recirculation is resorted to protect the water wall system
T
Economiser Waterwall Superheater
Circulation Systems
STEAM TO TURBINE STEAM TO TURBINE
SH
SH
EVAPORATOR
ECO.
Drum Type
EVAPORATOR
Ideally suited for sliding pressure operation due to the absence of thick walled components.
Design Features of 660 / 800 MW Supercritical Boilers for Indian Coal Fired Power Stations
Boiler Parameters
Description Boiler Parameters SH steam flow SHO pressure SHO/RHO temp. Feed water temp. t/h kg/cm2(a)
oC oC
Unit -
Features of Boiler
Pulverised coal fired Once through, evaporator suitable for variable pressure operation Single reheat Tilting Tangential firing System Dry Bottom Balanced draft furnace Side mill layout
800 MW
Once-Through
660 MW
Once-Through
500 MW
Controlled
Startup low load Vertical separator with Vertical separator recirculation System One no. startup Rewith One no. startup Not applicable circulation pump Re-circulation pump Water walls SH / RH / Economiser system Vertical walls with rifled tubing 2 stages of SH 2 stages of RH 1stage economizer Tilting tangential firing Balanced draft Spiral walls with Plain tubing Vertical walls with rifled tubing
2 stages of SH 3 stages of SH 2 stages of RH 1 stages of RH 1stage economizer 1stage economizer Tilting tangential Tilting tangential firing firing Balanced draft Balanced draft 1sT October 2008
Final RH Platen SH
Final SH
LTRH
Economiser
Boiler Auxiliaries
Description
Pulverisers Airheaters
800 MW
9 nos.HP bowl mill 2nos Regenerative Tri-sector air heater system
660 MW
9 nos.HP bowl mill 2 nos. Regenerative Tri-sector air heater system
500 MW
10 nos. bowl mill 2 nos. Regenerative Trisector air heater system or 4 nos Bisector air heater system with 2 nos. primary&2 nos. secondary. 2 Axial FD, 2 Axial PA and 2 Radial ID with VFD 50 mg/Nm3
Fans
Highlights
Boiler and Auxiliaries
Controlled Circulation( 3 CC Pumps) Smaller Dia Rifle Tubes for WW Bisector Airheater Two stage reheating Tower Type Once Through boiler with spiral
Highlights
Turbine and Auxiliaries
TD BFP FRF for governing system Vacuum Pump in place of ejector 4 stop and control valves for turbine Horizontal HP and LP heaters
2 Reheat stop and control (combined) 2 Swing check NRVs in cold reheat line 2 Bypass stop and control valves
1sT October 2008
irculating water
ype of Governing
ated speed
2 Hrs.
2 Hrs
900, 1548, 1896, 2700, 3858 400-2859 r.p.m 3350 r.p.m 240 . 210 (r.p.m.) cut-in /cut-out (Hydraulic)
1200,1600, 1900
traction 1-
traction 2-
traction 3-
traction 4,1-
traction 5-
traction 6
45 Kg. /cm2 (abs) 19.5 Kg / cm2 (abs) 428.3C 7.57 Kg / cm2 (abs) 302C 2.76 Kg / cm2 (abs) 197.8C 1.42 Kg / cm2 (abs) 138.8C 0286 Kg / cm2 (abs) 43C
39 Kg /cm2 (abc)
0.86 Kg /cm2 (abs) 107 2.216 Kg / cm2 (abs) 1sT October 2008
traction 1
Bypass trip