<$5m Construction Odinary Acceptable

<$10m Acceptable

<$20m Acceptable

<$100m

>$100m

Non Combustible FRC

Acceptable Acceptable

Acceptable Acceptable

Acceptable Acceptable

Not Acceptable Not Acceptable Unless Unless Sprinklered Sprinklered Acceptable Acceptable Acceptable Acceptable If Timber flooring tiled over & rooms segregated may accept up to $30M if full time brigade & hydrants/hosereel s

Fire Detection Thermal Smoke

Desirable Desirable

Mandatory

Vesda Fire Protection Sprinklers

Desirable

Desirable

Mandatory (In all Mandatory (In all areas including areas including air conditioning air conditioning return) return) Desirable Desirable

Mandatory

Desirable

Desirable

Desirable

DesirableMANDATORY IF NOT COMPARTMEN TED with <$50M per compartment

Mandatory

Pre action required in storage areas where large concentration of values

Thermographic Scanning Desirable Wiring (Certified Complaince with Desirable Australian Wiring Code) Security U.L. listed central station perimeter burglary alarms covering all exterior openings accessible and otherwise (i.e., windows, doors, walls, floors, ceilings Back-up power to alarm Line Security Interior motion detection

Electrics Switchboards (If not fire isolated)

Thermographic Scanning Desirable Desirable

Thermographic Thermographic Scanning Scanning Mandatory Mandatory Mandatory every Mandatory every 5 years 2 years

Thermographic Scanning Mandatory Mandatory Annually

Desirable

Mandatory

Mandatory

Mandatory

Mandatory

Desirable Desirable Desirable

Desirable Mandatory Desirable

Mandatory Mandatory Mandatory

Closed circuit television

Desirable

Desirable

Desirable

Background checks for contract Desirable Desirable Mandatory workers and volunteers Watchman Desirable Desirable Desirable Desirable Mandatory Individual Item Protection Required for High Value Items unless in "secure" inner room- define "high value">$2M. If any unit valued >$20M must be in secured inner room.

Mandatory inc. Mandatory inc. power loss alarm power loss alarm Mandatory Mandatory Mandatory Mandatoryinc.sensors which scan ceiling level Mandatory Mandatorymonitored off site continuously or sensor triggered Mandatory Mandatory

Inventory Controls Inventory of all items in the collection.

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Inventory Records Includes


Identification numbers location Current photograph appraisal Condition report party Specific Current Consignment

<$5m Mandatory

<$10m Mandatory

<$20m Mandatory

<$100m Mandatory

>$100m Mandatory

Duplicate records offsite or in fire rated storage

Desirable

Mandatory

Mandatory

Mandatory

Mandatory

HVAC Temperature Controls


Paper & Film: 60-65 F for storage 65-70 F for occupied areas Humidity Controls Paper 40% 45% RH Film generally 30% RH, but can vary with material

Desirable Desirable Desirable

Mandatory Mandatory Desirable

Mandatory Mandatory MandatoryA fault alarm would be OK? Mandatory Mandatory Mandatory

Mandatory Mandatory Mandatory

Mandatory Mandatory Mandatory

Controls monitored offsite

Back-up power Particulate Contamination


Filter to remove better than 50% of 0.5 micron particles.

Desirable Desirable Desirable

Desirable Mandatory Mandatorysuggest >$20M

Mandatory Mandatory Mandatory

Mandatory Mandatory Mandatory

Gaseous Contamination Controls


(SO2): 1-10 ppb (NOx): 5-10 ppb Ozone (03): 2-25 ppb

Infestation Controls

Desirable

Mandatory

Mandatory

Mandatory

Mandatory

Disaster Recovery Conservation Plans Art Loss Register

Desirable Desirable

Desirable Desirable

Mandatory Mandatory

Mandatory Mandatory

Mandatory Mandatory

Lighting
Storage: 1-5 Foot candles (11-55 Lux) Display: 5-15 Foot candles (55-165 Lux); Reading/Work Areas: 30-60 Foot candles (330-660 Lux) UV Content: <75 microwatts per lumen, <2 - 4% UV IR Content: limit with light levels or dichroic reflector lamps

Desirable

Desirable

Mandatory

Mandatory

Mandatory