Sie sind auf Seite 1von 8

VFD-C200series Launch Announcement

C200 Vector Micro Drive

Features
Field oriented control, FOC+PG, TQC+PG, PMsensorless Power range from 0.4kW to 7.5kW Built-in PLC function, program capacity 5k steps. Application IM & PM motor Built-in high-speed communication CANopen and Standard communication MODBUS Enhanced protections and adaptation to ambient conditions Complies with global safety standards (including CE, UL and cUL) High-performance and variable frequency technology Built-in high light LED keypad Advance PID function

Specification
230V Series -1 Phase
Frame Size Model VFD -_ _ _CB21A-_ _ _ Applicable Motor Output (kW) Applicable Motor Output (HP) Rated Output Capacity (kVA) Rated Output Current (A) NORMAL DUTY Output Rating Overload Tolerance Max. Output Frequency (Hz) Carrier Frequency (kHz) Rated Output Capacity (kVA) Rated Output Current (A) Overload Tolerance
*1

A0 004 0.4 0.5 1.2 3 007 015 0.75 1.5 1 2 2.0 3.2 5 8 rated output current is 120% for 60 seconds; rated output current is 160% for 2 seconds 600.00Hz 2~15kHz (Factory Setting: 8 kHz) 1.9 2.8 4.8 7.1 rated output current is 150% for 60 seconds; rated output current is 180% for 3 seconds 300.00Hz 2~15kHz (Factory Setting: 2 kHz) 12 15.7 11.5 14 AC 200V~240V (-15% ~ +10%), 50/60Hz, 1-Phase 170~265Vac 47~63Hz Natural cooling Fan cooling Built-in 022 2.2 3 4.4 11

Max. Output Frequency (Hz) Carrier Frequency (kHz) Input Current (A) Normal Duty Input Current (A) Heavy Duty Rated Voltage/Frequency Operating Voltage Range Frequency Tolerance Cooling method Braking Chopper

HEAVY DUTY

1.1 2.8

4.0 10

230V Series -3 Phase


Frame Size Model VFD -_ _ _CB23A-_ _ _ Applicable Motor Output (kW) Applicable Motor Output (HP) Rated Output Capacity (kVA) Rated Output Current (A) NORMAL DUTY Output Rating Overload Tolerance Max. Output Frequency (Hz) Carrier Frequency (kHz) Rated Output Capacity (kVA) Rated Output Current (A) Overload Tolerance
*1

Input Rating

7.2 6.7

22 20

A0 004 0.4 0.5 1.2 3 007 015 022 0.75 1.5 2.2 1 2 3 2.0 3.2 4.4 5 8 11 rated output current is 120% for 60 seconds; rated output current is 160% for 2 seconds 600.00Hz 2~15kHz (Factory Setting: 8 kHz) 1.1 1.9 2.8 4.0 2.8 4.8 7.1 10 rated output current is 150% for 60 seconds; rated output current is 180% for 3 seconds 300.00Hz 2~15kHz (Factory Setting: 2 kHz) 3.9 6.4 12 16 3.6 6.1 11 15 AC 200V~240V (-15% ~ +10%), 50/60Hz 3-Phase 170~265Vac 47~63Hz Natural cooling Fan cooling Built-in 037 3.7 5 6.8 17

Max. Output Frequency (Hz) Carrier Frequency (kHz) Input Current (A) Normal Duty Input Current (A) Heavy Duty Rated Voltage/Frequency Operating Voltage Range Frequency Tolerance Cooling method Braking Chopper

HEAVY DUTY

6.4 16

Input Rating

20 18.5

460V Series
Frame Size Model VFD-_ _ _CB43A-_ _ _ Applicable Motor Output (kW) Applicable Motor Output (HP) Rated Output Capacity (kVA) Rated Output Current (A) NORMAL DUTY Output Rating Overload Tolerance Max. Output Frequency (Hz) Carrier Frequency (kHz) Rated Output Capacity (kVA) Rated Output Current (A) Overload Tolerance
*1

A0 007 0.75 1 2.4 3.0

A 075 7.5 10 14 18

Max. Output Frequency (Hz) Carrier Frequency (kHz) Input Current (A) Normal Duty Input Current (A) Heavy Duty Rated Voltage/Frequency Operating Voltage Range Frequency Tolerance Cooling method Braking Chopper

015 022 037 040 055 1.5 2.2 3.7 4.0 5.5 2 3 5 5.5 7.5 3.2 4.8 7.2 8.4 10 4.0 6.0 9.0 10.5 12 rated output current is 120% for 60 seconds; rated output current is 160% for 2 seconds 600.00Hz 2~15kHz (Factory Setting: 8 kHz) 2.3 3.0 4.5 6.5 7.6 9.6 2.9 3.8 5.7 8.1 9.5 11 rated output current is 150% for 60 seconds; rated output current is 180% for 3 seconds 300.00Hz 2~15kHz (Factory Setting: 2 kHz) 4.3 5.9 8.7 14 15.5 17 4.1 5.6 8.3 13 14.5 16 AC 380V~480V (-15% ~ +10%), 50/60Hz 3-Phase 323~528Vac 47~63Hz Natural cooling Fan cooling Built-in

HEAVY DUTY

14 17

*1 _ _ _ " means models such as

Input Rating

20 19

-20 / -21 / -20M.

General Specifications
Control Method Starting Torque Speed Response Ability Torque Limit Torque Accuracy Max. Output Frequency (Hz) Frequency Output Accuracy Output Frequency Resolution Frequency Setting Signal Accel./decel. Time 1: V/F, 2: SVC, 3: VF+PG, 4: FOC+PG, Reach up to 150% or above at 0.5Hz. Under FOC+PG mode, starting torque can reach 150% at 0Hz. 5Hz (vector control can reach up to 40Hz) Max. 200% torque current 5% normal duty: 0.01~600.00Hz; Heavy duty: 0.00 ~ 300.00 Hz Digital command:0.01%, -10 ~+40 , Analog command: 0.1%, 2510 Digital command:0.01Hz, Analog command: 0.03 X max. output frequency/60 Hz (11 bit) +10V~-10 0~+10V 4~20mA 0-20mA 0.0~6000.0 seconds Torque control, Droop control, Speed/torque control switching, Feed forward control, Zero-servo control, Momentary power loss ride thru, Speed search, Over-torque detection, Torque limit, 16-step speed (max), Accel/decel time switch, S-curve accel/decel, 3-wire sequence, Auto-Tuning (rotational, stationary), Dwell, Cooling fan on/off switch, Slip compensation, Torque compensation, JOG frequency, Frequency upper/lower limit settings, DC injection braking at start/stop, High slip braking, PID control (with sleep function),Energy saving control, MODOBUS communication (RS-485 RJ45, max. 115.2 kbps), Fault restart, Parameter copy User Pr07-19 to control cooling fans. Electronic thermal relay protection For drive model 230V and 460V Over-current protection for 240% rated current current clamp Normal duty: 170~175% ; Heavy duty: 180~185% 230: drive will stop when DC-BUS voltage exceeds 410V 460: drive will stop when DC-BUS voltage exceeds 820V Built-in temperature sensor Stall prevention during acceleration, deceleration and running independently Leakage current is higher than 50% of rated current of the AC motor drive

Control Characteristics

Main control function

Fan Control Motor Protection Protection Characteristics Over-current Protection Over-voltage Protection Over-temperature Protection Stall Prevention Grounding Leakage Current Protection Certifications

GB/T12668-2

Environment for Operation, Storage and Transportation


DO NOT expose the AC motor drive in the bad environment, such as dust, direct sunlight, corrosive/inflammable gasses, 2 humidity, liquid and vibration environment. The salt in the air must be less than 0.01mg/cm every year. Installation IEC60364-1/IEC60664-1 Pollution degree 2, Indoor use only location o o Storage -25 C ~ +70 C Surrounding Transportation -25 oC ~ +70 oC Temperature Non-condensation, non-frozen Operation Max. 90% Storage/ Max. 95% Rated Humidity Transportation No condense water Operation/ 86 to 106 kPa Storage Environment Air Pressure Transportation 70 to 106 kPa IEC721-3-3 Operation Class 3C2; Class 3S2 Pollution Level Storage Class 2C2; Class 2S2 Transportation Class 1C2; Class 1S2 No concentrate If AC motor drive is installed at altitude 0~1000m, follow normal operation restriction. If it is install at altitude 1000~3000m, decrease Operation Altitude 2% of rated current or lower 0.5 of temperature for every 100m increase in altitude. Maximum altitude for Corner Grounded is 2000m. Storage ISTA procedure 1A(according to weight) IEC60068-2-31 Package Drop Transportation 1.0mm, peak to peak value range from 2Hz to 13.2 Hz; 0.7G~1.0G range from 13.2Hz to 55Hz; 1.0G Vibration range from 55Hz to 512 Hz. Comply with IEC 60068-2-6 Impact Operation Position IEC/EN 60068-2-27 Max. allowed offset angle 10 installation position)
o

(under normal

10

10

Specification for Operation Temperature and Protection Level


Model VFDxxxCBxxA-20 IP20 / UL Open Type

VFDxxxCBxxA-21

IP20 / NEMA1

VFDxxxCBxxA-21M

IP20 / UL Open Type

*2: The model names end by "-21M" are models which have strengthen cover cases. When the temperature

current will start to decrease by 2% as the temperature increases by 1

is between

-10~35

, the rated current remains at 100%, but if the temperature increases to 36

, the rated

*2

-10~40

-10~40

Frame Frame A0~A 230V: 0.4~3.7kW 460V: 0.75~7.5kW Frame A0~A 230V: 0.4~3.7kW 460V: 0.75~7.5kW Frame A0~A 230V: 0.4~3.7kW 460V: 0.75~7.5kW

Top cover

Conduit Box -10~50

Model Name
VFD 007 CB 43 A - 21 M
Protection mode Blank means standard models M Strengthen cover case protected models 20 IP20/UL Open Type 21: IP20/NEMA1 Installation mode Wall Mounting Input voltage
: :

C200 Series Applicable motor capcity 004:0.5HP(0.375kW)~ 075:10HP(7.5kW) Refer to the specifications for details Series name (Variable Frequency Drive)

Serial Number

007 CB EA I T 1 08 0001
Prcoduction number Prcoduction week Prcoduction year (2011) Prcoduction factory
T:Taoyuan W: Wujian S: Shanghai

EA 460V 3 PHASE BA 230V 1-PHASE DA: 230V 3-PHASE

1HP(0.75kW)

Model number

CB: C200 CM: C200

I IP20/UL Open Type J: IP20/NEMA1

Wiring Diagram
* It provides 1-phase/3-phase power Fuse/NFB(No Fuse Breaker) R(L1) S(L2) T(L3)
SA It is recommended to install a MC protective circuit at RB-RC to protect it from system damage. When fault occurs, the ON OFF contact will switch ON to shut the power and protect the power system.MC

Please refer to chapter 5 Main Circuit Terminals

+2 +1/DC+ DC- B1

B2

R(L1) S(L2) T(L3)

U(T1) V(T2) W(T3)

Motor

IM 3~

RB 1 RC 1

Factory setting: NPN (SINK) Mode Please refer to Figure 1 for wiring of NPN mode and FWD/STOP PNP mode. REV/STOP Multi-step 1 Multi-step 2 Multi-step 3 Factory Multi-step 4 setting N/A N/A N/A N/A Digital Signal Common

+24V COM FWD REV MI1 MI2 MI3 MI4 MI5 MI6 MI7 MI8 DCM

RA1 RB1 RC1 RA2 RB2 RC2

Multi-function output terminals


250Vac/5A (N.O.) 250Vac/3A (N.C.) 250Vac/2A (N.O.) Estimate at COS (0.4) 250Vac/1.2A (N.C.) Estimate at COS (0.4) 30Vdc/5A (N.O.) 30Vdc/3A (N.C.)

DFM1 Multi-function output


frequency terminals 30V30mA 33kHz

NOTE

* MI7, MI8 can input33kHz pulses * Do NOT apply the mains voltage directly to above terminals.

DFM2 DCM Multi-function


Photocoupler Output

+10V/20mA SW1
0 -2 0 mA 4 -2 0 mA

+10V AVI ACI AUI ACM


8 1

5K

3 2 1

0~10V/0~20mA 4~20mA/0~10V -10~+10V

AFM1 ACM AFM2

Analog Multi-function Output Terminal 0~10VDC Analog Signal common Analog Multi-function Output Terminal 0~20mA/4-20mA Mo d b u s R S-4 8 5 SG + PIN 3 :G N D PIN 4 :SG SG PIN 5 :SG + C AN o p e n PIN 1 : C AN H PIN 2 : C AN L PIN 3 , 7 :G N D PIN 6 : Re se rve d PIN 8 : EV

Analog Signal Common


0 -1 0 V AC I AVI

Main circuit (power) terminals Control terminals Shielded leads & Cable
J5

120 485 O PEN

Application
6

Package machine

Conveyor

Textile machine

Wood machine

Release Area Release 2011.11 2012.1 Area Taiwan, China India, Euro, America, Africa, Australia, South Asia Remarks

Competition
Yaskawa J1000 V1000

Mitsubishi D700 E700

Fuji Mini Multi

Schneider ATV11 ATV12 ATV312

Das könnte Ihnen auch gefallen