Field oriented control, FOC+PG, TQC+PG, PMsensorless Power range from 0.4kW to 7.5kW Built-in PLC function, program capacity 5k steps. Application IM & PM motor Built-in high-speed communication CANopen and Standard communication MODBUS Enhanced protections and adaptation to ambient conditions Complies with global safety standards (including CE, UL and cUL) High-performance and variable frequency technology Built-in high light LED keypad Advance PID function
Specification
230V Series -1 Phase
Frame Size Model VFD -_ _ _CB21A-_ _ _ Applicable Motor Output (kW) Applicable Motor Output (HP) Rated Output Capacity (kVA) Rated Output Current (A) NORMAL DUTY Output Rating Overload Tolerance Max. Output Frequency (Hz) Carrier Frequency (kHz) Rated Output Capacity (kVA) Rated Output Current (A) Overload Tolerance
*1
A0 004 0.4 0.5 1.2 3 007 015 0.75 1.5 1 2 2.0 3.2 5 8 rated output current is 120% for 60 seconds; rated output current is 160% for 2 seconds 600.00Hz 2~15kHz (Factory Setting: 8 kHz) 1.9 2.8 4.8 7.1 rated output current is 150% for 60 seconds; rated output current is 180% for 3 seconds 300.00Hz 2~15kHz (Factory Setting: 2 kHz) 12 15.7 11.5 14 AC 200V~240V (-15% ~ +10%), 50/60Hz, 1-Phase 170~265Vac 47~63Hz Natural cooling Fan cooling Built-in 022 2.2 3 4.4 11
Max. Output Frequency (Hz) Carrier Frequency (kHz) Input Current (A) Normal Duty Input Current (A) Heavy Duty Rated Voltage/Frequency Operating Voltage Range Frequency Tolerance Cooling method Braking Chopper
HEAVY DUTY
1.1 2.8
4.0 10
Input Rating
7.2 6.7
22 20
A0 004 0.4 0.5 1.2 3 007 015 022 0.75 1.5 2.2 1 2 3 2.0 3.2 4.4 5 8 11 rated output current is 120% for 60 seconds; rated output current is 160% for 2 seconds 600.00Hz 2~15kHz (Factory Setting: 8 kHz) 1.1 1.9 2.8 4.0 2.8 4.8 7.1 10 rated output current is 150% for 60 seconds; rated output current is 180% for 3 seconds 300.00Hz 2~15kHz (Factory Setting: 2 kHz) 3.9 6.4 12 16 3.6 6.1 11 15 AC 200V~240V (-15% ~ +10%), 50/60Hz 3-Phase 170~265Vac 47~63Hz Natural cooling Fan cooling Built-in 037 3.7 5 6.8 17
Max. Output Frequency (Hz) Carrier Frequency (kHz) Input Current (A) Normal Duty Input Current (A) Heavy Duty Rated Voltage/Frequency Operating Voltage Range Frequency Tolerance Cooling method Braking Chopper
HEAVY DUTY
6.4 16
Input Rating
20 18.5
460V Series
Frame Size Model VFD-_ _ _CB43A-_ _ _ Applicable Motor Output (kW) Applicable Motor Output (HP) Rated Output Capacity (kVA) Rated Output Current (A) NORMAL DUTY Output Rating Overload Tolerance Max. Output Frequency (Hz) Carrier Frequency (kHz) Rated Output Capacity (kVA) Rated Output Current (A) Overload Tolerance
*1
A 075 7.5 10 14 18
Max. Output Frequency (Hz) Carrier Frequency (kHz) Input Current (A) Normal Duty Input Current (A) Heavy Duty Rated Voltage/Frequency Operating Voltage Range Frequency Tolerance Cooling method Braking Chopper
015 022 037 040 055 1.5 2.2 3.7 4.0 5.5 2 3 5 5.5 7.5 3.2 4.8 7.2 8.4 10 4.0 6.0 9.0 10.5 12 rated output current is 120% for 60 seconds; rated output current is 160% for 2 seconds 600.00Hz 2~15kHz (Factory Setting: 8 kHz) 2.3 3.0 4.5 6.5 7.6 9.6 2.9 3.8 5.7 8.1 9.5 11 rated output current is 150% for 60 seconds; rated output current is 180% for 3 seconds 300.00Hz 2~15kHz (Factory Setting: 2 kHz) 4.3 5.9 8.7 14 15.5 17 4.1 5.6 8.3 13 14.5 16 AC 380V~480V (-15% ~ +10%), 50/60Hz 3-Phase 323~528Vac 47~63Hz Natural cooling Fan cooling Built-in
HEAVY DUTY
14 17
Input Rating
20 19
General Specifications
Control Method Starting Torque Speed Response Ability Torque Limit Torque Accuracy Max. Output Frequency (Hz) Frequency Output Accuracy Output Frequency Resolution Frequency Setting Signal Accel./decel. Time 1: V/F, 2: SVC, 3: VF+PG, 4: FOC+PG, Reach up to 150% or above at 0.5Hz. Under FOC+PG mode, starting torque can reach 150% at 0Hz. 5Hz (vector control can reach up to 40Hz) Max. 200% torque current 5% normal duty: 0.01~600.00Hz; Heavy duty: 0.00 ~ 300.00 Hz Digital command:0.01%, -10 ~+40 , Analog command: 0.1%, 2510 Digital command:0.01Hz, Analog command: 0.03 X max. output frequency/60 Hz (11 bit) +10V~-10 0~+10V 4~20mA 0-20mA 0.0~6000.0 seconds Torque control, Droop control, Speed/torque control switching, Feed forward control, Zero-servo control, Momentary power loss ride thru, Speed search, Over-torque detection, Torque limit, 16-step speed (max), Accel/decel time switch, S-curve accel/decel, 3-wire sequence, Auto-Tuning (rotational, stationary), Dwell, Cooling fan on/off switch, Slip compensation, Torque compensation, JOG frequency, Frequency upper/lower limit settings, DC injection braking at start/stop, High slip braking, PID control (with sleep function),Energy saving control, MODOBUS communication (RS-485 RJ45, max. 115.2 kbps), Fault restart, Parameter copy User Pr07-19 to control cooling fans. Electronic thermal relay protection For drive model 230V and 460V Over-current protection for 240% rated current current clamp Normal duty: 170~175% ; Heavy duty: 180~185% 230: drive will stop when DC-BUS voltage exceeds 410V 460: drive will stop when DC-BUS voltage exceeds 820V Built-in temperature sensor Stall prevention during acceleration, deceleration and running independently Leakage current is higher than 50% of rated current of the AC motor drive
Control Characteristics
Fan Control Motor Protection Protection Characteristics Over-current Protection Over-voltage Protection Over-temperature Protection Stall Prevention Grounding Leakage Current Protection Certifications
GB/T12668-2
(under normal
10
10
VFDxxxCBxxA-21
IP20 / NEMA1
VFDxxxCBxxA-21M
*2: The model names end by "-21M" are models which have strengthen cover cases. When the temperature
is between
-10~35
, the rated
*2
-10~40
-10~40
Frame Frame A0~A 230V: 0.4~3.7kW 460V: 0.75~7.5kW Frame A0~A 230V: 0.4~3.7kW 460V: 0.75~7.5kW Frame A0~A 230V: 0.4~3.7kW 460V: 0.75~7.5kW
Top cover
Model Name
VFD 007 CB 43 A - 21 M
Protection mode Blank means standard models M Strengthen cover case protected models 20 IP20/UL Open Type 21: IP20/NEMA1 Installation mode Wall Mounting Input voltage
: :
C200 Series Applicable motor capcity 004:0.5HP(0.375kW)~ 075:10HP(7.5kW) Refer to the specifications for details Series name (Variable Frequency Drive)
Serial Number
007 CB EA I T 1 08 0001
Prcoduction number Prcoduction week Prcoduction year (2011) Prcoduction factory
T:Taoyuan W: Wujian S: Shanghai
1HP(0.75kW)
Model number
Wiring Diagram
* It provides 1-phase/3-phase power Fuse/NFB(No Fuse Breaker) R(L1) S(L2) T(L3)
SA It is recommended to install a MC protective circuit at RB-RC to protect it from system damage. When fault occurs, the ON OFF contact will switch ON to shut the power and protect the power system.MC
+2 +1/DC+ DC- B1
B2
Motor
IM 3~
RB 1 RC 1
Factory setting: NPN (SINK) Mode Please refer to Figure 1 for wiring of NPN mode and FWD/STOP PNP mode. REV/STOP Multi-step 1 Multi-step 2 Multi-step 3 Factory Multi-step 4 setting N/A N/A N/A N/A Digital Signal Common
+24V COM FWD REV MI1 MI2 MI3 MI4 MI5 MI6 MI7 MI8 DCM
NOTE
* MI7, MI8 can input33kHz pulses * Do NOT apply the mains voltage directly to above terminals.
+10V/20mA SW1
0 -2 0 mA 4 -2 0 mA
5K
3 2 1
Analog Multi-function Output Terminal 0~10VDC Analog Signal common Analog Multi-function Output Terminal 0~20mA/4-20mA Mo d b u s R S-4 8 5 SG + PIN 3 :G N D PIN 4 :SG SG PIN 5 :SG + C AN o p e n PIN 1 : C AN H PIN 2 : C AN L PIN 3 , 7 :G N D PIN 6 : Re se rve d PIN 8 : EV
Main circuit (power) terminals Control terminals Shielded leads & Cable
J5
Application
6
Package machine
Conveyor
Textile machine
Wood machine
Release Area Release 2011.11 2012.1 Area Taiwan, China India, Euro, America, Africa, Australia, South Asia Remarks
Competition
Yaskawa J1000 V1000