Sie sind auf Seite 1von 6

JCI

JC International Limited RC 413243


Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Date of Examination 1030 P.O.NO. 173490 Identification Number 10/09/10 Examiner PREYE ONYUKU Qualifications ASNT LEVEL II

Description of Equipment:

TORQUE ARRESTOR ROD

XXX1

OD-3.1/2 Length- 6.73ft

METHOD: THE CRITICAL AREAS WERE CLEANED TO BARE METAL AND MAGNETIC PARTICLE INSPECTION WAS CARRIED OUT. RESULTS: THERE WAS NO CRACK FOUND AT THE TIME OF INSPECTION.
SPECIFICATION : ASTM E709 MPI METHOD: RESULTS: Wet Visible No crack at the time of inspection. TEST PROCEDURE: JOP-020

MAGNETIC FIELD INDICATOR: Burmah Castrol Strip MAGNETIC PARTICLES: Wet Visible

MATERIAL: Carbon steel. EQUIPMENT USED: Permanent Magnet. SERIAL NO. : A706 TEST WEIGHT: 40 LBS COMSUMABLES USED: White contrast paint Black magnetic ink

Name and address of equipment owner: KCA DEUTAG LTD

Address of premises where Test / Examination was held:

WEST CAPELLA

We hereby certify that on 10/09/11 (date) no crack was found on the item/s described on this certificate as at the time of inspection.

ACCEPTABLE
Signature of Inspector: Revision No: 01 Name of Inspector: PREYE ONYUKU. Doc No: JCIC-020

Cert No.227173

JCI

JC International Limited RC 413243


Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Date of Examination 1031 P.O.NO. 173490 Identification Number 10/09/10 Examiner PREYE ONYUKU Qualifications ASNT LEVEL II

Description of Equipment:

TORQUE ARRESTOR ROD

XXX2

OD-3.1/2 Length- 6.73ft

METHOD: THE CRITICAL AREAS WERE CLEANED TO BARE METAL AND MAGNETIC PARTICLE INSPECTION WAS CARRIED OUT. RESULTS: THERE WAS NO CRACK FOUND AT THE TIME OF INSPECTION.
SPECIFICATION : ASTM E709 MPI METHOD: RESULTS: Wet Visible No crack at the time of inspection. TEST PROCEDURE: JOP-020

MAGNETIC FIELD INDICATOR: Burmah Castrol Strip MAGNETIC PARTICLES: Wet Visible

MATERIAL: Carbon steel. EQUIPMENT USED: Permanent Magnet. SERIAL NO. : A706 TEST WEIGHT: 40 LBS COMSUMABLES USED: White contrast paint Black magnetic ink

Name and address of equipment owner: KCA DEUTAG LTD

Address of premises where Test / Examination was held:

WEST CAPELLA

We hereby certify that on 10/09/11 (date) no crack was found on the item/s described on this certificate as at the time of inspection.

ACCEPTABLE
Signature of Inspector: Revision No: 01 Name of Inspector: PREYE ONYUKU. Doc No: JCIC-020

Cert No.227173

JCI

JC International Limited RC 413243


Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Date of Examination 1032 P.O.NO. 173490 Identification Number 10/09/10 Examiner PREYE ONYUKU Qualifications ASNT LEVEL II

Description of Equipment:

TORQUE ARRESTOR ROD

XXX3

OD-3.1/2 Length- 6.73ft

METHOD: THE CRITICAL AREAS WERE CLEANED TO BARE METAL AND MAGNETIC PARTICLE INSPECTION WAS CARRIED OUT. RESULTS: THERE WAS NO CRACK FOUND AT THE TIME OF INSPECTION.
SPECIFICATION : ASTM E709 MPI METHOD: RESULTS: Wet Visible No crack at the time of inspection. TEST PROCEDURE: JOP-020

MAGNETIC FIELD INDICATOR: Burmah Castrol Strip MAGNETIC PARTICLES: Wet Visible

MATERIAL: Carbon steel. EQUIPMENT USED: Permanent Magnet. SERIAL NO. : A706 TEST WEIGHT: 40 LBS COMSUMABLES USED: White contrast paint Black magnetic ink

Name and address of equipment owner: KCA DEUTAG LTD

Address of premises where Test / Examination was held:

WEST CAPELLA

We hereby certify that on 10/09/11 (date) no crack was found on the item/s described on this certificate as at the time of inspection.

ACCEPTABLE
Signature of Inspector: Revision No: 01 Name of Inspector: PREYE ONYUKU. Doc No: JCIC-020

Cert No.227173

JCI

JC International Limited RC 413243


Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Date of Examination 1033 P.O.NO. 173490 Identification Number 10/09/10 Examiner PREYE ONYUKU Qualifications ASNT LEVEL II

Description of Equipment:

TORQUE ARRESTOR ROD AND TORQUE ARRESTOR FRAME

XXX4

OD-3.1/2 Length- 6.73ft

Length- 8.35ft METHOD: THE CRITICAL AREAS WERE CLEANED TO BARE METAL AND MAGNETIC PARTICLE INSPECTION WAS CARRIED OUT. RESULTS: THERE WAS NO CRACK FOUND AT THE TIME OF INSPECTION.
SPECIFICATION : ASTM E709 MPI METHOD: RESULTS: Wet Visible No crack at the time of inspection. TEST PROCEDURE: JOP-020

MAGNETIC FIELD INDICATOR: Burmah Castrol Strip MAGNETIC PARTICLES: Wet Visible

MATERIAL: Carbon steel. EQUIPMENT USED: Permanent Magnet. SERIAL NO. : A706 TEST WEIGHT: 40 LBS COMSUMABLES USED: White contrast paint Black magnetic ink Name and address of equipment owner: KCA DEUTAG LTD Address of premises where Test / Examination was held:

WEST CAPELLA

We hereby certify that on 10/09/11 (date) no crack was found on the item/s described on this certificate as at the time of inspection.

ACCEPTABLE
Signature of Inspector: Revision No: 01 Name of Inspector: PREYE ONYUKU. Doc No: JCIC-020

Cert No.227173

JCI

JC International Limited RC 413243


Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Date of Examination 1034 P.O.NO. 173490 Identification Number 10/09/10 Examiner PREYE ONYUKU Qualifications ASNT LEVEL II

Description of Equipment:

SPLIT COLLAR SLEEVE, TORQUE ARRESTOR SLEEVE AND SECURING BOLT


Split Collar Sleeve OD: 12.3/4 Length: 0.75ft

570510

4 pcs of Securing Bolt OD: 1.19/32; Length: 1.20ft

4pc Torque Arrestor Sleeve

METHOD: THE CRITICAL AREAS WERE CLEANED TO OD: 4.5/8; Length: 0.44ft BARE METAL AND MAGNETIC PARTICLE INSPECTION WAS CARRIED OUT. RESULTS: THERE WAS NO CRACK FOUND AT THE TIME OF INSPECTION.
SPECIFICATION : ASTM E709 MPI METHOD: RESULTS: Wet Visible No crack at the time of inspection. TEST PROCEDURE: JOP-020

MAGNETIC FIELD INDICATOR: Burmah Castrol Strip MAGNETIC PARTICLES: Wet Visible

MATERIAL: Carbon steel. EQUIPMENT USED: Permanent Magnet. SERIAL NO. : A706 TEST WEIGHT: 40 LBS COMSUMABLES USED: White contrast paint Black magnetic ink

Name and address of equipment owner: KCA DEUTAG LTD

Address of premises where Test / Examination was held:

WEST CAPELLA

We hereby certify that on 10/09/11 (date) no crack was found on the item/s described on this certificate as at the time of inspection.

ACCEPTABLE
Signature of Inspector: Revision No: 01 Name of Inspector: PREYE ONYUKU. Doc No: JCIC-020

Cert No.227173

JCI

JC International Limited RC 413243


Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Date of Examination 1035 P.O.NO. 173490 Identification Number 10/09/10 Examiner PREYE ONYUKU Qualifications ASNT LEVEL II

Description of Equipment:

TORQUE ARRESTOR FRAME

135327 SPLIT COLLAR POS 1 (Z78920)


Length- 0.74ft

METHOD: THE CRITICAL AREAS WERE CLEANED TO BARE METAL AND MAGNETIC PARTICLE INSPECTION WAS CARRIED OUT. RESULTS: THERE WAS NO CRACK FOUND AT THE TIME OF INSPECTION.
SPECIFICATION : ASTM E709 MPI METHOD: RESULTS: Wet Visible No crack at the time of inspection. TEST PROCEDURE: JOP-020

MAGNETIC FIELD INDICATOR: Burmah Castrol Strip MAGNETIC PARTICLES: Wet Visible

MATERIAL: Carbon steel. EQUIPMENT USED: Permanent Magnet. SERIAL NO. : A706 TEST WEIGHT: 40 LBS COMSUMABLES USED: White contrast paint Black magnetic ink

Name and address of equipment owner: KCA DEUTAG LTD

Address of premises where Test / Examination was held:

WEST CAPELLA

We hereby certify that on 10/09/11 (date) no crack was found on the item/s described on this certificate as at the time of inspection.

ACCEPTABLE
Signature of Inspector: Revision No: 01 Name of Inspector: PREYE ONYUKU. Doc No: JCIC-020

Cert No.227173