Product facts Talos RDR Revolving Doors

Revolving Doors RDR Basic equipment


RDR-E01

Produktqualitt Einbruchhemmende Bauteile nach DIN V ENV 1627 Nr. 219 6032868

Note Construction outside diameter entrance and emergency escape width total height passage height body top number of door wings rotary cycle additional feature Body side panels thermal separation safety strips top cover/ceiling maintenance openings Rotating unit

2100 3700 see schedule page 6 2300 2100 200 4 or 3 (optional) 180 or 120 (optional) optional: tested category resistance WK 2 (RC 2) with glazing 8 mm laminated glass, alternative metal cladded on facade level top cover raw aluminium plate, dust-proof two, in the lower ceiling plate framed in aluminium profiles T40 one pane safety toughened glass with sealing brushes black U-shaped handles bar-lock prepared for profile cylinder on-site powder coated in a RAL colour or silver anodized free motion manually, smooth running on finished floor level (FFL)

Finish Function Installation

All dimensions in mm

RDR-C01

Produktqualitt Einbruchhemmende Bauteile nach DIN V ENV 1627 Nr. 219 6032868

additional options in comparison to RDR-E01 2100 3700 see schedule page 6 2300 2100 200 4 or 3 (optional) 180 or 120 (optional) optional: tested category resistance WK 2 (RC 2), WK 3 with glazing 8 mm laminated glass, alternative metal cladded on facade level top cover raw aluminium plate, dust-proof two, in the lower ceiling plate framed in aluminium profiles T40 one pane safety toughened glass with sealing brushes black U-shaped handles bar-lock prepared for profile cylinder on-site powder coated in a RAL colour or silver anodized free motion manually, smooth running on finished floor level (FFL)

official member of

Revolving Doors RDR Basic equipment


RDR-C03

Produktqualitt Einbruchhemmende Bauteile nach DIN V ENV 1627 Nr. 219 6032868

Note Construction outside diameter entrance and emergency escape width total height passage height body top number of door wings rotary cycle additional feature Body side panels thermal separation safety strips top cover/ceiling maintenance openings Rotating unit

including emergency escape function, activation by means of emergency off-switch located at inner corner post 2100 3700 see schedule page 6 2300 2100 200 4 or 3 (optional); on centrical bearings 180 or 120 (optional) on request with glazing 8 mm laminated glass, alternative: metal cladded on facade level on opposite shearing edges top cover raw aluminium plate, dust-proof two, in the lower ceiling plate framed in aluminium profiles T56 one pane safety toughened glass, including break-out symbols to stick on the door wings with sealing brushes black U-shaped handles horizontal and vertical at the door wings two bar bolts to lock the rotating unit to the top and to the bottom powder coated in a RAL colour or silver anodized fully automatic K8-SA1 with OPL 01 and KGB emergency escape module start of motion by means of infrared sensors reverse push-button in the entrance sectors two push-buttons, 20, for those with reduced mobility two emergency off-switches control system integrated in the unit power supply 230 VAC, 50 Hz on finished floor level (FFL)

safety bars Finish Function

Electrical components Installation

All dimensions in mm

RDR-S01

RDR-C02

Produktqualitt Einbruchhemmende Bauteile nach DIN V ENV 1627 Nr. 219 6032868

Produktqualitt Einbruchhemmende Bauteile nach DIN V ENV 1627 Nr. 219 6032868

2100 3300 (in case of T40 3700) see schedule page 6 2230 2100 130 4 or 3 (optional) 180 or 120 (optional) optional WK 2 with glazing 8 mm laminated glass on facade level glass ceiling consisting of 2 laminated glass segments framed in aluminium profiles T25 ( 3700 T40) one pane safety toughened glass with sealing brushes black U-shaped handles bar-lock prepared for profile cylinder on-site (closing downwards) powder coated in a RAL colour or silver anodized free motion manually, smooth running

3920 - 4920 see schedule page 6 2400 2200 200 4 or 3 (optional) ; on centrical bearings 180 or 120 (optional) with glazing 8 mm laminated glass, alternative: metal cladded on facade level on opposite shearing edges top cover raw aluminium plate, dust-proof in the lower ceiling plate framed in aluminium profiles T56 one pane safety toughened glass with sealing brushes without handles horizontal and vertical at the door wings two bar bolts prepared for profile cylinder on-site 1000 powder coated in a RAL colour or silver anodized SA3 servo drive with OPL 03, rotates at walking speed start of motion by means of infrared sensors two pre-sensors, installed in ceiling plate reverse push-button in the entrance sectors two push-buttons, 20, for those with reduced mobility two emergency off-switches control system integrated in the unit power supply 230 VAC, 50 Hz on finished floor level (FFL)

on finished floor level (FFL)

1000

1050

DH=2200 GH=DH+DR

DR

2557-3264 3800-4800 3920-4920

1050

DH=2200 GH=DH+DR

DR

Schedules
RDR-E01 and RDR-C01 outside 2100 2200/2300 2400/2500 2600/2700 2800/2900 3000/3100 3200/3300 3400/3500 3600/3700 outside 2100 2200/2300 2400/2500 2600/2700 2800/2900 3000/3100 3200/3300 3400/3500 3600/3700 outside 2100 2300 2500 2700 2900 3100 3300 3700 outside 3920 4120 4320 4520 4720 4920 inside 2000 2100/2200 2300/2400 2500/2600 2700/2800 2900/3000 3100/3200 3300/3400 3500/3600 inside 2000 2100/2200 2300/2400 2500/2600 2700/2800 2900/3000 3100/3200 3300/3400 3500/3600 inside 2000 2200 2400 2600 2800 3000 3200 3600 inside 3800 4000 4200 4400 4600 4800 entrance width 1332 1402/1474 1544/1615 1685/1756 1826/1897 1968/2039 2109/2180 2251/2322 2392/2463 entrance width 1300 1370/1440 1510/1580 1650/1720 1790/1860 1930/2000 2070/2140 2210/2280 2350/2420 entrance width 1332 1474 1615 1756 1897 2039 2180 2463 entrance width 2557 2698 2839 2981 3122 3264 emerg. esc. width 1825 1925 2025 2125 2225 2325 emerg. esc. width 925 975/1025 1075/1125 1175/1225 1275/1325 1375/1425 1475/1525 1575/1625 1675/1725

RDR-C03

RDR-S01

RDR-C02

Console 1 in plastic in RAL 9006 e.g. for installation of contactless reader

Console 4 in stainless steel satin finish

Console 5 in stainless steel satin finish

release push-button

OPL 01 OPL 02 OPL 03

key switch

width 94 mm height 94 mm depth 65 mm

width 118 mm height 93 mm depth 60 mm

width 118 mm height 164 mm depth 60 mm

Construction increase of passage height increase of body top glass ceiling without frame (side panels 12 mm laminated glass) water tray or waterproof cover of outer part of body, in aluminium insulation of body top outside resistance class P4A, shatter resistant glazing of body and rotating unit or rotating unit in P4A combined with metal side panels in resistance class WK 2 (RC 2) miscellaneous night slides motor for night slides monitoring of night closure, notification of status closed or closed and locked rotating unit 3 wings (120) rotating unit T40, VSG in resistance class P4A rotating unit T25 or T40 foldable, every wing is manually foldable, including bolt-lock and separate contacts for electrical transmission, up to outside 3300 stainless steel handle horizontal or vertical, installed on door wings monitoring of locking closing upwards (not -S01) or downwards floor element in stainless steel for advance installation drive fixation in floor pit or as underfloor suspension drive stainless steel tub for outside floor ring (connection to draining) sealing foil at the outer radius or in facade axis clamping rail for fixing of sealing foil stainless steel plate, may be perforated, to apply floor covering stainless steel frame/fitting panel for floor element cleaning mats or black rubber mat (optionally equipped with arrow) or carpet as cleaning zone Finish stainless steel AISI 304 satin finish or mirror finish S8 finish E6 anodised in colour Function speed control to prevent too strong speeding up of door (recommended) SA1 servo positioning drive turns rotating unit into passaging speed (starting by manual push), including electric transmission kit, safety strips horizontal and vertical, key switch for free turning of door, release button (reverse push-button), two emergency off-switches and two handicapped buttons 20, optionally with OPL 01 SA1-stage of extension locking on demand BV1 SA2 servo positioning drive, turns rotating unit into basic position; including key switch for free turning of door, finger protection strips on the bottom of door wings and two emergency off-switches, optionally with OPL 02 as well as locking on demand BV2 function day-/night access, activation by included key-switch (locking on demand necessary) transport opening Electrical components infrared (not with C02, standard with -C03) or radar motion detectors for automatic starting handicapped buttons 70 x 70 in console 4 with wheelchair symbol, alternatively to the handicapped buttons existing with SA1 different consoles key button or switch operating panels OPL 01 or OPL 02, functions can be chosen freely emergency stop push-button with seal cap instead of the existing one two pre-sensors in case of heavy rotating units, for additional safeguarding of person groups who have to be especially protected sensor rails to reduce speed of rotating unit when pedestrian is detected by sensors lighting 2 - 4 halogen spots lighting 3, 4, 6, 8, 9, 12, halogen spots All dimensions in mm

RDR-C02

RDR-C03

RDR-C01

RDR-E01

RDR-S01

Options for RDR Revolving Doors dependant on unit type

= standard

Safety device

Rotating units RDR Rotating unit T25 120 outside diameter: 2100 3300 1. toughened glass 2. safety strip 3. sealing brush 4. safety strip (with SA1) 5. finger protection strip (with SA2, N0 and N0-LR) Rotating unit without centre column. Depth of profiles 25 mm.

Rotating unit T25 180 outside diameter: 2100 3300 1. toughened glass 2. safety strip 3. sealing brush 4. safety strip (with SA1) 5. finger protection strip (with SA2, N0 and N0-LR) Rotating unit without centre column. Depth of profiles 25 mm.

Rotating unit T40 120 outside diameter: 2100 3700 1. laminated glass 2. safety strip 3. sealing brush 4. safety strip (with SA1) 5. finger protection strip (with SA2, N0 and N0-LR) Rotating unit without centre column. Depth of profiles 40 mm.

Rotating unit T40 180 outside diameter: 2100 3700 1. laminated glass 2. safety strip 3. sealing brush 4. safety strip (with SA1) 5. finger protection strip (with SA2, N0 and N0-LR) Rotating unit without centre column. Depth of profiles 40 mm.

All dimensions in mm

Rotating units RDR Rotating unit T56 120 escape function outside diameter: 2100 3700 1. laminated glass 2. safety strip 3. sealing brush 4. safety strip 5. finger protection strip Rotating unit with centre column and escape function. Depth of profiles 56 mm.

Rotating unit T56 180 escape function outside diameter: 2100 3700 1. laminated glass 2. safety strip 3. sealing brush 4. safety strip 5. finger protection strip Rotating unit with centre column and escape function. Depth of profiles 56 mm.

All dimensions in mm

Floor elements for RDR types Floor element without stainless steel frame for sealing

Floor element with stainless steel frame for sealing

10

Detail: floor element with sealing foil at the outer radius 1. sealing foil 300 mm (self adhesive) or foil on-site 2. stainless steel elbow fitting 3. stainless steel ring (25 mm) 4. clamping rail with welded stud M8 5. fitting panel X: installation depth SFL to FFL

Detail: floor element with sealing foil in facade axis 1. sealing foil 300 mm (self adhesive) or foil on-site 2. stainless steel elbow fitting 3. stainless steel strut for connection and support 4. installation of bearing on the floor 5. fitting panel X: installation depth SFL to FFL

All dimensions in mm

Floor elements for RDR types Drive box for floor pit

Stainless steel plate for floor element


11

Stainless steel plate for floor element perforated (for drainage)

Floor element with water tray

All dimensions in mm

Alternative body types for RDR Body with floor element Body with dustproof cover

1

Body with waterproof cover

Body with water tray and drain pipe

All dimensions in mm

Alternative body types for RDR Body with night closure Body glass ceiling with frame

1

Body glass ceiling with point fixing

Body glass ceiling without frame

In case of integration of the RDR-S01 into the facade axis we recommend an additional weather protection by a roof with an appropriate down-grade. All dimensions in mm

Connections RDR Example for wall connection 200 on top side Example for lateral wall connection 200

1

Subsurface drive

All dimensions in mm

Assembly diagram for instance Talos RDR-E01 (rotary cycle 180), with emergency escape door according to DIN EN 179

1

All dimensions in mm

Kaba Gallenschtz GmbH, subject to modifications 10001E 82010

Kaba Gallenschtz GmbH Nikolaus-Otto-Strasse 1 1 Bhl Germany Tel. + (0) /-0 Fax + (0) /-111 info@kgb.kaba.com www.kaba-gallenschuetz.de