Sie sind auf Seite 1von 8

Alga Double Acting Pneumatic Actuator

Scotch Yoke Design

Double Acting Pneumatic Quarter-Turn Actuator For


Output Torques to 2,200,000 lb.in.

Features and benefits


Scotch yoke design generates high break
torque needed for the actuation of many
quarter-turn valves.
Six bearings provide reliability, smooth
operation and extended service life:
- Two bronze yoke bearings ensure
minimal friction.
- Two bronze sliding block bearings
spread load over large surface area.
- Guide block bearing and piston rod
bearing of sintered bronze impregnated
with PTFE increase efficiency, reduce
maintenance and prolong actuator life.
Graphite-impregnated PTFE piston
bearing reduces friction between the
piston and cylinder bore and allows the
cylinder to be operated without lubrication.
Guide bar supports the transverse forces
and insures proper support of the piston
rod. Hard chrome plating on guide bar
provides corrosion resistance and minimal
friction loads.
Chrome-plated piston rods provide
maximum corrosion resistance and
minimal friction loads on dynamic seals.
Electroless nickel-plated cylinder bore
provides maximum corrosion resistance
and reliability.
Multiple external tie bar design provides
maximum cylinder integrity.
Totally enclosed, weatherproof carbon
steel housing provides maximum strength.
Internal coating protects against corrosion.
External travel stops allow precise
adjustments of 4 rotation at each end
of travel.
Low hysteresis and high response
enhance modulating service.
Available with canted or with symmetric
scotch yoke mechanism to suit the valve
characteristics.
Special coatings for offshore or corrosive
environments.
Special version available for use with sour
gas supply.
ATEX certified
II 2 G D

Options and accessories

Technical data

Accessory mounting brackets provided for


mounting of controls or enclosures.
Manual jackscrews and hydraulic manual
overrides optional.
Spring return actuators available.

Supply pressure
Supply medium

General application
Designed for on-off or modulating control of
quarter-turn Ball, Butterfly, Plug or Damper
style valves.

: 20 to 150 psig
: air, nitrogen or sweet
gas
Output torque
: To 2,200,000 lb.in.
Ambient temperature
standard range
: -20F to 210F
(-30C to 100C)
optional ranges : -65F to 300F
(-55C to 150C)

Tyco reserves the right to change the content without notice

BIFRM-0021-US-0312

Alga Double Acting Pneumatic Actuator


Scotch Yoke Design

Materials
Part
1
2
3
4
5
6
7
8

Housing
Yoke
Yoke bearing
Cover
Guide block pin
Sliding block
Guide block
Guide bar

Material

Carbon steel
Carbon steel
Bronze
Carbon steel
Alloy steel
Bronze
Carbon steel
Alloy steel
(hard chrome plated)
9 Guide block bearing Steel + bronze + PTFE
10 Travel stop screw
Carbon steel
11 Cylinder head flange Carbon steel
12 Piston rod bearing
Steel + bronze + PTFE
13 Piston rod seal
NBR rubber
14 Piston rod
Alloy steel
(hard chrome plated)
15 Piston
Carbon steel
16 Piston bearing
PTFE + graphite
17 Piston seal O-ring
NBR rubber
18 Cylinder tube
Carbon steel (ENP)
19 Cylinder end flange Carbon steel
20 Travel stop screw
Carbon steel
21 Sealing washer
PVC
22 Tie rod
Alloy steel
23 Cylinder seal O-ring NBR rubber

Material Standards
ASTM A537 cl1 + ASTM A283 gr D
API 5LX gr X52 (C<0.2%) + ASTM A537 cl1
ASTM B427 Alloy UNS No. C90800
ASTM A283 gr D
AISI SAE 9840
ASTM B427 Alloy UNS No. C90800
ASTM A537 cl1
AISI SAE 9840
(chromium plated)

AISI SAE 1040


ASTM A283 gr D

AISI SAE 9840


ASTM A283 gr D

API 5LX GR X52


ASTM A283 gr D
AISI SAE 1040

AISI SAE 9840

Tyco reserves the right to change the content without notice

page 2

Alga Double Acting Pneumatic Actuator


Overall dimensions
A
F

C
B

N
P

flK

L
M

Pneumatic
connection to close

Pneumatic
connection to open
Mounting bracket (optional)

Front

Top

Overall dimensions
Actuator
model

0.3*-135
0.3*-175
0.3*-235
0.9*-235
0.9*-280
1.5*-280
1.5*-335
1.5*-385
3.0*-385
3.0*-485
6.0*-485
6.0*-585
14*-635
18*-685
18*-735

28.8
29.3
29.3
31.9
31.8
36.5
36.5
36.2
51.4
51.7
59.0
59.2
65.9
77.0
77.0

12.6
12.6
12.6
16.3
16.7
18.2
19.1
20.1
23.6
25.8
28.5
30.7
33.7
37.6
38.5

11.7
12.1
13.2
13.7
15.4
20.1
18.8
21.1
21.1
25.2
25.2
29.8
31.9
35.0
37.0

5.4
5.4
5.4
6.3
6.3
7.4
7.4
7.4
11.2
11.2
12.9
12.9
14.8
16.6
16.6

5.9
5.9
5.4
7.5
7.5
8.5
8.5
8.5
12.6
12.5
14.4
14.4
16.6
18.7
18.7

8.7
8.7
8.7
9.7
9.7
11.5
11.5
11.5
15.4
15.4
16.9
16.9
19.5
21.6
21.6

20.0
20.6
20.7
22.2
22.1
24.9
24.9
24.7
36.0
36.3
42.1
42.3
46.3
55.4
55.4

6.1
7.9
10.2
10.2
13.6
13.6
15.8
17.7
17.7
22.1
22.1
26.4
28.4
30.3
32.1

2.76
2.76
2.76
3.15
3.15
3.94
3.94
3.94
6.30
6.30
7.28
7.28
7.87
9.06
9.06

4.7
4.7
4.7
6.7
6.7
7.3
7.3
7.3
8.5
8.5
10.2
10.2
11.6
13.4
13.4

2.8
2.8
2.8
3.3
3.3
3.9
3.9
3.9
4.2
4.2
5.5
5.5
7.6
7.7
7.7

Pneumatic connection
NPT
Weight
P To close To open
(lbs)
0.3
1.2
2.4
1.9
3.5
2.9
3.9
4.9
4.7
6.9
5.5
7.7
6.6
7.4
8.4

1/4
1/4
1/2
1/2
1/2
1/2
1/2
1/2
1/2
3/4
3/4
3/4
1
1
1

1/4
1/2
1/2
1/2
3/4
3/4
1
1
1
1
1
1
1
1
1

117
141
181
207
273
366
428
500
679
855
1129
1552
2756
3417
3638

A
F

G
D

C
B

N
P

Pneumatic connection
to close

flK
L
M

Pneumatic
Pneumatic
connection to close connection to open

Pneumatic
connection to open

Mounting bracket (optional)

Front

Top

Overall dimensions
Actuator
model

18*2-635
32*2-685

105.9
122.4

36.8
41.3

32.0
35.0

15.6
19.2

18.3
22.4

51.6
59.6

54.3
62.8

28.7
30.3

9.06
10.63

13.4
15.6

7.7
9.1

Pneumatic connection
NPT
Weight
P To close To open
(lbs)
6.7
6.0

1
1

1
1

4300
5400

Notes
1. All dimensions are in inches unless otherwise noted.
2. Weights refer to base construction (without adapter).
3. *Add C for canted yoke, S for symmetric yoke.
Tyco reserves the right to change the content without notice

page 3

Alga Double Acting Pneumatic Actuator


Mounting dimensions

N. threaded holes d2 x h deep


p.c.d. number and size
according to ISO 5211
(but the holes are on centerline
instead of straddle the centerline)

N. 12 hole flange

PCD

Actuator models 14 to 32

N. threaded holes d2 x h deep


p.c.d. number and size according to
ISO 5211

W
K

N. 16 hole flange

Flow line

PCD

N. 4 hole flange

N. 8 hole flange

Actuator models 0.3 to 6.0

Top view of the scotch yoke mechanism


(actuator shown in closed position)

Top view of the scotch yoke mechanism


(actuator shown in closed position)

Coupling dimensions
Actuator
model
PCD
0.3
0.9
1.5
3.0
6.0
14
18
32

6.496
10
11.732
14.016
15.984
19.016
23.740
23.470

d1
9.45
12.20
14.17
16.93
20.47
22.8
26.7
30.7

Notes

d2*

M20x2.5 4
M16x2
8
M20x2.5 8
M30x3.5 8
M36x4
8
M36x4 12
M36x4 16
M36x4 16

h
0.67
0.75
0.75
0.90
1.14
1.14
1.26
1.26

Standard
bore
d3
Depth
2.756
3.386
4.409
6.181
7.874
6.890
7.874
8.661

Keyway
W

4.80
5.70
7.26
7.54
9.65
13.00
13.33
15.23

12
14
18
25
28
45
45
50

mm
mm
mm
mm
mm
mm
mm
mm

K
75.6
93.6
119.0
167.8
212.8
195.8
220.8
242.8

mm
mm
mm
mm
mm
mm
mm
mm

Stem acceptance dimensions for insert bushings


Max. stem diameter
with square key
(key dimension)

0.3
0.9
1.5
3.0
6.0
14
18
32

2.05
2.60
3.34
4.72
5.90

(0.55)
(0.63)
(0.71)
(1.26)
(1.41)

Max. stem diameter


with rectangular
key ()
2.16
2.75
3.54
5.12
6.69
Not Applicable
Not Applicable
Not Applicable

Tyco reserves the right to change the content without notice

1. All dimensions are in inches unless otherwise


noted (Keyway dimension W & K are mm.).
2. * Thread according to ISO R261
3. d1 is maximum adapter flange diameter.

Notes
Square
stem

Maximum
stem
protrusion**

S
W

Housing
size

Flow line

1.81
2.16
2.87
4.09
5.23

2.52
3.03
4.06
5.78
7.40

4.72
5.51
7.08
7.48
9.48

page 4

1. The listed maximum acceptance


values are applicable for stems with
keyway parallel or perpendicular to
the flow line and for square stems with
diagonal parallel with the flow line.
2. Key according to UNI6604 or DIN
6885 sh.1 or BS4325 part 1 or ISO
773 or equivalent.
3. S max: maximum external diameter
in case of rounded edge.
4. **Without adapter flange.

Alga Double Acting Pneumatic Actuator


Scotch Yoke Design

Notes

Operating data

1. Maximum operating torque is maximum


rating of scotch yoke mechanism.
2. Maximum allowable pressure is 150 psig
(static pressure applicable to fully stroked
actuator against travel stops).
3. Maximum operating pressure is the pressure
required to produce the maximum operating
torque of the actuator.

Air
Consumption
(cu.in.)

Actuator
Model
0.3C-135
0.3C-175
0.3C-235
0.9C-235
0.9C-280
1.5C-280
1.5C-335
1.5C-385
3.0C-280
3.0C-485
6.0C-485
6.0C-585
14C-635
18C-685
18C-735
18C2-635
32C2-685

Maximum operating pressure


Canted
Symmetric
(psig)
(psig)

177
294
553
553
854
976
1404
1891
2870
4515
5187
7570
9703
12693
14584
21785
29719

150
100
50
130
90
130
90
60
80
50
90
60
90
100
80
60
70

Maximum operating
torque
(lb.in.)

150
150
80
150
130
150
120
90
110
70
130
80
130
150
130
80
110

22000
22000
22000
61000
61000
104000
104000
104000
220000
220000
440000
440000
870000
1300000
1300000
1300000
2200000

Accessories mounting dimensions


Actuator
model A
0.3
0.9
1.5
3.0
6.0
14
18
32

3.1
3.6
3.6
4.6
5.4
12.4
12.4
12.4

6.10
7.28
7.28
9.25
17.91
24.80
24.80
24.80

2.36
2.36
2.36
3.35
4.53
7.87
7.87
7.87

0.55
0.55
0.55
0.91
0.91
1.06
1.06
1.06

0.2
0.2
0.2
0.3
0.3
0.4
0.4
0.4

4.5
6.1
6.9
8.0
9.8
8.9
8.9
15.2

4.7
6.7
7.3
8.5
10.2
13.0
13.4
15.6

1.5
2.4
2.4
2.2
2.3
3.8
2.8
2.8

0.5 3.6
1.4 3.4
1.4 5.1
1.0 9.1
0.9 8.8
2.2 8.7
1.3 12.1
1.3 16.3

Front

Back

7.87
7.87
11.81
19.69
19.69
19.69
26.77
35.04

2.36
2.36
3.94
3.94
3.94
6.69
8.46
8.46

0.55
0.55
0.55
0.55
0.55
1.06
1.06
1.06

1.4
1.9
1.8
2.1
3.4
3.9
3.2
5.9

0.2
0.2
0.2
0.2
0.3
0.3
0.4
0.4

7.9
9.6
11.2
14.6
18.9
21.4
23.6
26.0

5.51
5.51
5.51
6.30
6.30
6.30
12.36
12.36

2.76
2.76
2.76
5.00
5.00
5.00
24.80
24.80

2.76
2.76
2.76
5.35
5.35
5.35
7.87
7.87

N4M10
N4M10
N4M10
N4M16
N4M16
N4M16
N4M16
N4M16

Top

Top view
accessory mounting pad

M
L

.39 .39
.47 .87
.47 .87
.47 .47
.51 1.18
.63 .63
.71 1.38
.63 1.30

S
C
H

W x X deep

N
Q
J

Line flow

G
E

Front

Tyco reserves the right to change the content without notice

W x Y deep

Front

page 5

Alga Double Acting Pneumatic Actuator


Canted Yoke Design
Output torques (lb.in.)
Actuator
model

Angular
position

0.3C-135

0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)

0.3C-175

0.3C-235

0.9C-235

0.9C-280

1.5C-280

1.5C-335

1.5C-335

3.0C-385

3.0C-485

6.0C-485

6.0C-585

14C-635

18C-685

18C-735

18C2-635

32C2-685

Operating pressure (psig)


70
80
90

40

50

60

100

110

120

4880
5220
1880
2550
8300
9010
3240
4400
15100
16600
5960
8100
17500
19200
6890
9370
24900
27100
9730
13200
31500
34300
12300
16700
45300
49500
17700
24200
60300
66200
23700
32300
99800
109500
39200
53500
159500
175800
63000
85800
186400
205500
73600
100300
272200
300700
107700
146800
350600
386600
138400
188800
469200
516600
184900
252200
540100
595400
213100
290700
802700
890800
318800
434900
1097200
1217600
436300
594500

6190
6620
2380
3230
10500
11400
4090
5560
19100
20900
7520
10200
22100
24200
8690
11800
31400
34100
12300
16700
39700
43200
15400
21100
57000
62400
22300
30500
75800
83200
29800
40600
125400
137700
49300
67200
200200
219900
79100
107700
234100
258000
92400
126000
341500
377200
135200
184200
439800
485000
173600
236800
588600
648100
232000
316400
677600
746900
267300
364700
1007000
1117500
400000
545600
1376500
1527600
547300
745800

7490
8020
2880
3910
12700
13800
4950
6730

8800
9410
3380
4600
14900
16200
5800
7890

10100
10800
3880
5280
17100
18500
6660
9050

11400
12200
4390
5960
19300
20900
7520
10200

12700
13600
4890
6640

14000
15000
5390
7330

15300
16400
6390
8010

16600
17800
7400
8690

26600
29200
10490
14300
37900
41200
14800
20100
47900
52100
18600
25400
68800
75200
26900
36700
91300
100200
35900
48900
151100
165800
59400
81000

31200
34200
12300
16700
44400
48200
17300
23600
56100
61000
21800
29800
80500
88100
31500
43000

35800
39300
14100
19200
50900
55300
19900
27000
64300
69900
25000
30100
92300
100900
36100
49300

40400
44300
15900
21600
57400
61000
22400
30400
72600
78800
28200
38500

44900
49300
17700
24100

49500
54300
19500
26200

54100
59300
23100
29000

58600
60900
22700
31400

80800
87800
31600
42900

89000
96700
34800
47200

97200
103900
41200
51600

176800
194000
69500
94700

202400
219900
79600
108500

329300
363000
130100
177200

376900
415500
148900
202800

618300
681900
244000
332900
827400
911100
326100
444800
952600
1050100
375800
512700

707500
780300
279300
381000
946800
1042600
373200
509000
1090100
1201600
430100
586700

281700
310500
111200
151600
410800
439900
162600
221500
529000
583400
208800
284900
708000
779600
279000
380600
815100
898500
321600
438700
1211300
1299900
481100
656300
1655800
1837500
658300
897200

796700
869900
314500
429000
1066200
1174100
420200
573300

1935000
2147500
769400
1048500

Maximum operating pressure is the pressure required to produce the maximum rated torque of the actuator model.
Maximum allowed pressure is 150 psig (static pressure applicable to fully stroked actuator against the travel stops).
CCW = Counterclockwise rotation
CW = Clockwise rotation
Tyco reserves the right to change the content without notice

page 6

1185600
1299800
467300
637500

130

Alga Double Acting Pneumatic Actuator


Symmetric Yoke Design
Output torques (lb.in.)
Actuator
model

Angular
position

0.3S-135

0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)
0* break (CCW)
0* seating (CW)
Run
90* full open (CCW)

0.3S-175

0.3S-235

0.9S-235

0.9S-280

1.5S-280

1.5S-335

1.5S-385

3.0S-385

3.0S-485

6.0S-485

6.0S-585

14S-635

18S-685

18S-735

18S2-635

32S2-685

40

50

60

3060
3310
1880
3070
5210
5710
3240
5300
9490
10500
5960
9760
11000
12200
6890
11300
15600
17200
9730
15900
21500
23500
12300
18400
30800
34000
17700
26600
41000
45500
23700
35600
67000
74300
39200
59800
107100
119200
63000
96000
125000
139100
73600
112500
182500
203600
107700
164600
238600
265700
138400
208000
319200
355000
184900
278100
367500
409100
213100
320500
546100
612100
318800
479500
737000
826000
436300
665300

3880
4190
2380
3890
6580
7220
4090
6700
12000
13300
7520
12300
13800
15300
8690
14200
19700
21600
12300
20700
27000
29700
15400
23200
38800
42900
22300
33600
51600
57200
29800
44800
84300
93400
49300
75200
134500
149700
79100
120600
156900
174700
92400
141200
229000
255400
135200
206500
299300
333400
173600
261000
400400
445300
232000
348800
461000
513200
267300
402000
685100
767900
400000
601500
924600
1036200
547300
834600

4700
5080
2880
4710
7960
8730
4950
8100
14500
16000
9080
14900
16700
18500
10490
17200
23800
26100
14800
24200
32600
35800
18600
28000
46800
51700
26900
40500
62100
68900
35900
53900
101500
112500
59400
90600
161800
180100
95100
145100
188900
210200
111200
170000
275400
307300
162600
248400
360000
401000
208800
313900
481700
535700
279000
419600
554600
617400
321600
483600
824100
923700
481100
723500
1112100
1246500
658300
1004000

Operating pressure (psig)


70
80
90
5520
5960
3380
5540
9330
10200
5800
9500
16900
18800
10600
17400
19600
21700
12300
20100
27900
30600
17300
28400
38200
41900
21800
32800
54800
60500
31500
47400
72700
80600
42000
63100
118700
131600
69500
106000
189200
210600
111200
169600
220800
245800
130100
198700
321900
359100
190000
290300
420800
468600
244000
366900
562900
626000
326100
490400
648100
721500
375800
565200
963100
1079500
562300
845600
1299700
1456700
769400
1173300

6340
6850
3880
6360
10700
11700
6660
10900
19400
21500
12200
20000
22400
24900
14100
23100
31900
35000
19900
32500
43800
48100
25000
37600
62800
69400
36100
54300
83200
92300
48000
72200
136000
150700
79600
121400

252700
281300
148900
227500
368400
410900
217400
332200
481500
536300
279300
419800
644200
716400
373200
561200
741600
825600
430100
646700
1102100
1235300
643400
967600
1487300
1667000
880400
1342700

100

110

130

150

7150
7740
4390
7180
12100
13300
7520
12300

7970
8260
4890
8000
13500
14800
8370
13700

8790
9510
5390
8820
14800
16300
9230
15100

10400
11300
6390
10500
17600
19300
10900
17900

12100
13000
7400
12100
20300
22900
12700
20700

25300
28000
15900
26000
36000
39500
22400
36700
49400
54200
28200
42400
70800
78200
40700
61200
93800
103900
54100
81400
153200
169900
89700
136800

28200
31200
17700
29000
40100
44000
24900
40800
55000
60300
31600
47200
78800
87000
45300
68100

31000
34400
19500
31900
44100
48400
27500
44900
60500
66400
34800
52000
86800
95800
49900
75000

36800
40700
23100
37800
52300
57400
32500
53200
71700
78700
41200
61600

42500
47100
26700
43700

170500
189000
99800
152200

187700
208100
109900
167600

284700
316900
167700
256200

316600
352400
186500
284900

348500
388000
205300
313700

412400
439900
242900
371200

542200
603900
314500
472800
725400
806800
420200
631900
835200
929800
484300
728300

602900
671600
349700
525700
806700
897100
467300
702700
928700
1033900
538500
809900

663700
739200
384900
578700
887900
987500
514400
773500
1022200
1138100
592800
891500

785100
869900
455400
684600
1050400
1168200
608500
915100
1209300
1299700
701300
1054600

1674900
1877200
991500
1512000

1862500
2087500
1102500
1681300

2050100
2199800
1213600
1850700

82900
91000
47400
71200

1212900
1299800
702600
1056600

Maximum operating pressure is the pressure required to produce the maximum rated torque of the actuator model.
Maximum allowed pressure is 150 psig (static pressure applicable to fully stroked actuator against the travel stops).
CCW = Counterclockwise rotation
CW = Clockwise rotation
Tyco reserves the right to change the content without notice

page 7

Alga Double Acting Pneumatic Actuator


Scotch Yoke Design

Canted and Symmetric scotch yoke torque output


Alga actuators are available with either canted or symmetric scotch yoke mechanisms.
The canted version produces a torque output as represented in Fig 1 and is therefore most suitable
for use with valves which display a similar torque requirement, such as butterfly valves.
The torque output characteristics of the symmetric version are as shown in Fig 2 and are most
suitable for use with valves which display a similar torque requirement, such as ball valves.

ALGA (double acting)


symmetric yoke mechanism

0
Closed

models 1.5 and larger

Torque

Torque

ALGA (double acting)


canted yoke mechanism

45
Angular Position

Fig. 1

90
Open

models 0.3-0.9

0
Closed

45
Angular Position

90
Open

Fig. 2

Other control products

Tyco AVID Control Position Monitors

Tyco AVID analogue positioners

Biffi manual override device

Biffi control panel

Tyco reserves the right to change the content without notice

Tyco AVID intelligent positioners

page 8