Electrical estimate for Wiring , Airconditioning, Computer and Light fittings NOTE: ALL GROVES/CUTS/CHASE IN WALLS/COLUMNS/SLABS SHALL BE MADE

BY THE ELECRICAL CONTRACTOR FOR INSTALLATION OF CONDUITS/SB/BOXES ETC AND MAKING GOOD THE SAME TO THE ORIGINAL FINISH COMPLETE IN ALL RESPECTS INCLUDING MATERIALS AND LABOUR. THE RATE SHOULD BE QUOTED FOR THE DIFFERENT ITEMS CONSIDERING THE ABOVE POINTS. ALL RELATED WORKS SHALL BE IN THE SCOE OF THE ELECTRICALCONTRACTOR. Sl.No. DescriptionofItems Unit Quantity Rate(inRs.) Amount(inRs.) 1.00 1 Dismentling the existing internal wiring and computer JOB data cabling, giving temperory connection for wiring and computer data cabling to run the branch premises and dismentling the same after completion of wiring and datacabling. 2 INTERNALWIRING Providing and making point wiring in walls, false ceiling, ceiling beams, furniture etc with MS conduits of 20 mm dia of 16 SWG ISI marked with bends,tees, elbows etc with 650V grade ISI marked 2 X 1.5 Sq. mm + 1 Sq. mm for loop earthing PVC insulated copper conductor multi standard flexible single core wires with all accessories viz screws and washers 5A piano type modular switches of Anchor/Havels/Roma with 3 mm thick hylam cover plates, fan regulators, 5A plugs and outlet boxes its accessories and angle holder/batten holder/ceiling rose etc complete in all respects to the satisfaction of the employer including the provision of circuit wiring with 3 X2.5Sq.mmabovePVCinsulatedcopperwire. 30.00 6.00 Existing 2.00

2(a) One5Aswitchcontrollingonelightpoint. EACH 2(b) 5A socket outlet (3 pin) with 5A SP switch as an EACH independentpoint. 2(c) Callbellpointwithbellpushcompleteinallrespect. EACH 3 Providing and installation of 20A SP MCB with 20A metal EACH clad socket all enclosed in a pre fabricated MS box of reputed manufacturer complete in all respects including internalconnections(HavellsMake). Do as in item no. 3 but with 30A TPN MCB with 30A EACH metal clad socket all enclosed in prefabricated MS box completetothesatisfactionofE.I.C(withoutwiring)

Existing

5(a) 2 X 4.0 Sq. mm + 1 X 2.5 Sq. mm PVC insulated copper MTR conductor wires (20A metal clad sockets for A.C up to 1.5TR/EquivalentloadasdecidedbytheEIC) 5(b) 4 X 4.0 Sq. mm + 1.25 Sq. mm PVC insulated copper MTR conductor wires (for 30A metal clad sockets or equivalentloadasdecidedbyteEIC) 5(c) 4 X 10.0 Sq. mm + 1 X 4 Sq. mm PVC insulated copper MTR conductor wires (for UPS, DBS, or equivalent load as decidedbytheEIC)

200.00

Existing

Existing

SUPPLY,INSTALLATIONOFLIGHTINGFIXTURE Supply & Installation testing and commissioning of under noted fixture with the help of flexible wires with down rod of 19 mm dia MS conduit/MS flexible pipe including all required materials as per the satisfaction of EICfromholder/Ceilingrodtothefixture. EACH EACH EACH Existing 40.00 12.00

6(a) Callbell/bellwithindicatorincludingsupply 6(b) Philipscatno.DN622completewith18WattCFLlamp. 6(c) Philips cat no. TBS088/418 M2 HPF recess mounting completewithfluorescenttube. TELEPHONE 7(a) Providing and installation of telephone socket (RJ 11) with top of MK/North West/Havels make telephone socket outlets and concealed boxes with front modular plate etc in/on walls/furniture etc complete in all respectstothesatisfactionoftheemployer 7(b) Supply and installation of any reputed make intercome EPABX set 10 nos with main control panel including connections for 10 sets with the provision of expansion for up to 25 sets complete in all respects with the provision of one P & T line 7(c) Providing,installation and drawing of two pair telephone wire of 0.5 Sq. mm PVC Insulated tinned copper ITI approved wire in 20 mm dia PVC rigid 2 mm thick approved make conduit complete with all accessories as required 8 Supply,installation and termination of KRON 25 pair telephone tag block in enclosure with proper ferule numberingcompleteinallrespects. 9 Provding and making earth electrode by using 600 X 600 X 6 mm GI plate as per IS3043 1987, including all required materials, making necessary chamber, top CI lockable cover, watering arrangement etc including breaking and removal of RCC/PCC cement concrete floor etc if required and redoing the same to the original finish complete in all respects to the satisfaction of the employer CABLEANDTERMINATION 10 Supplylayingtestingandcommissioningofthefollowing sizes of PVC insulated armoured cable aluminium/copper conductor of 1100V grade to be laid under ground to the minimum depth of 760 mm elow ground level, putting same in bottom and top of the cable with the provisin of brick side and top, restoring the surface duly rammed to the original finish or to be laid on wall or in existing pipe etc, with saddles, clamps andothermaterialsasrequiredcompleteinallrespects. 10(a) 10(b) 10(c) 10(d) 3.5X9.5Sq.mmPVCAcable 3.5X50Sq.mmPVCACable 4X16Sq.mmPVCACable 4X6Sq.mmPVCACable

EACH

Existing

EACH

Existing

MTR

Existing

EACH

Existing

EACH

Existing

MTR MTR MTR MTR

Existing Existing Existing Existing

11

Supply and termination of above cable with cable gland and plug of proper size by using crimping tool complete inallrespectstothesatisfactionoftheemployer. MTR MTR MTR MTR Existing Existing Existing Existing

11(a) 11(b) 11(c) 11(d)

3.5X9.5Sq.mm 3.5X50Sq.mm 4X16Sq.mm 4X6Sq.mm DISTRIBUTIONBOARDPANEL 12 Supply installation testing and commissioning of factory assembled distribution board having incoming MCB/Isolator and outgoing MCBs as detailed below with neutral lin, suitable to operate on 415 V AC system and having overload as well as short ckt tripping elements with breaking capacity of 9KA to be installed on surface of the wall or concealed as per direction with transperent window cover complete with 200A copper bus bar and inter connections as requied complete in all respects 12(a) L.D.B(4WAYTPN) Incoming:40A4PoleE.L.M.C.B Outgoing:6A1P.M.C.B(9Nos)20AM.C.B1p(3Nos)

EACH

Existing

12(b) P.D.B(4WAYTPN) Incoming:63A4PoleIsolator Outgoing:20ASPMCB(12Nos) 13

EACH

Existing

MAINPANEL 200A TPN F S U as incomer 200A TPN 440V, 50 Hz Alm EACH Bus bar. Ammeter and voltmeter with selector switch, phaseindicatorlampsfornormalaswellasDGsupply. Outgoing:63ATPNMCBIsolator 40ATPNMCBIsolator(2Nos) COMPUTERWIRING Computer socket outlet cluster point wiring with 1100V grade 3 Nos single core green earth 2.5 Sq. mm PVC insulated flexible fexible FRLS copper conductor wire conforming to IS 694 through 20 mm dia PVC conduit ISI marked and conduit accessories partly concealed in walls/embadded in floor by chase cutting mending good all damages to the original finish painting etc as required.Twocomputersocketasonepoint.

Existing

14

14(a) 3 nos 6A 3 pin shutter socket outlet with 6A controlling EACH switchforeachsocketofSSK/Havels/MK 1No.frontplateofhylam3mmofsuitablesize 1No.mountingMSboxofsuitablesize 14(b) 3 Nos. 16/6A 6 pin shutter socket outlet with 16A EACH commoncontrollingswitchofAnchor 1No.frontplateofsuitablesizeofNorthwest/MK

10.00

1.00

EARTHING 15(a) Making earth electrode as per IE rule conforming to IS EACH 3043 1987 or latest amendment by making earth station with 600 X 600 X 3 mm thick copper plate electrode to be installed such that its top edge shall be at a minimum depth of 3.5 m beow ground level after preparation of ground with charcoal and salt and connecting 25 mm X 3 mm copper earth lead in top up to10mlengthbyboltingandthanbrazingtothecopper plate with copper bolt of suitable length double nuts and washers, pipe with funnel for watering arrangement. The copper strip shall be PVC sleeved/insulated through the total length with heavy duty rigid PVC conduit (ISI marked embossed on cnduit surface) to be laid at an average depth of 500 mm below ground level. The earth staton should be provided with 300 X 300 X 300 mmdepth inside dimension masonary inspection pit with CI inged cover having locking arrangement of size 150 X 32 X mm copper plat connected to copper lead in top and restoring the 15(b) Extra earth lead in flat excluding 10 m length as MTR mentioned above with supply and fixing of 25 X 3 mm copper strip wth tinned copper bar saddle/clamp at an interval of 300 mm complete in all respects with all required materials. The minimum clearance between wallsurfaceandstripshouldbe6mm. 16 Supply and laying of 25 mm dia PVC conduit ISI MTR embossed complete with circular box, elbows, bends, couplejunctionboxincludingallaccessoriesasrequired, partly on surface above false ceiling, partly through partition and partly concealed in wall/embadded in floor by chase cutting mending good all damages to the original finish painting etc as required for information andcomputerdatacablelength. 17
Supply and fixing on wall / furniture / partition recessed type EACH make Computer data socket (RJ 45) with suitable mounting box&frontplateasshowninthedrawingcompletewithchase cutting,mendinggoodetc.asrequired. Supplying and laying of CAT 6e cables through prelaid rigid MTR PVC conduit as shown in the drawing or otherwise as directed by the consultant from server to HUB, HUB to Computer Data Socket including interconnection mending good etc. as requiredtobecompletedinallrespect.

Existing

Existing

400.00

20.00

18

600.00

19

Sub main wiring with 1100V grade with single core 2 MTR nos. 6 Sq. mm plus 1 nos. 4 Sq. mm (green for earth) PVC insulated flexible and FRLS copper conductor cable conforming to IS 694 through suitable size MS conduit (ISI embossed) and accessories patly on surface above false ceiling with MS bar saddle, partly through partition and mending good all damages paintingetc. as required inallrespects. Supply and installation of following MCB DBs with MCBs EACH having breaking capacity minimum of 9 KA and RCCBs of 300 MA sensitivity factor assembled and tested complete in all respects including interconnections to be installed on wall with the help of flat iron or flushes with finished wall by case cutting, mending good all damages painting etc as required. SPN 10 WAYS consumer unit double door with bus bar and the following RCCBs/MCBs(MDSorequivalentmake)

Existing

20

2.00

Incomer:1no.250V32ADPRCCB300MAsensitivity. Outgoing:10Nos250V16ASPMCBs. 21 Supply installation testing and commissioning of following wall mounted industrial type metal clad socket with plug top and MCB/RCCBs control DB having suitable length of bus bar chamber in 2 mm thick steel enclosure to be installed on MS angle frame on wall. The DB shall be suitable for operation on 415/230V 3 phase 4 wire/1 phase 2 wire 50 Hz AC system with TPN/SPN tinned copper bus bar of suitable size and 2 X 20 X 3 mm copper earth bus bar covering the total length of switch board with drilled holes copper bolts, nuts, washers etc. The switch board should be painted with 2 coats of synthetic primer. Approval of manfacturer from the employer/engineer is required. The DB consist of: 21(a) 1no.32A/40A5pinsocketwithmatchingplug. EACH 1no.32A/40A4pin(300MAsensitivity)RCCB. 21(b) 3no.32A/40A3pinsocketwithmatchingplug EACH 32A/40A SPN controlling MCB complete with interconnectionetcasrequired.

Existing Existing

TOTAL