BSC6900 GSM V900R011C00 Parameter Reference

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, plea or company headquarters.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: Email:

http://www.huawei.com support@huawei.com

Copyright Huawei Technologies Co., Ltd. 2011. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawe

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders.

vice. For any assistance, please contact our local office

rior written consent of Huawei Technologies Co., Ltd.

tive holders.

Purpose

This document provides information about the BSC6900 parameters, including the meaning, value, and usage o parameters.

Intended Audience
Network planners Field engineers System engineers Shift operators

Organization
Each parameter is described in the following aspects. Description Parameter ID Parameter Name NE MML Command Meaning Feature ID Feature Name Value Type GUI Value Range Actual Value Range Unit Default Value Recommended Value Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Performance

Network

Introduced in Version Attribute

ation about the BSC6900 parameters, including the meaning, value, and usage of the

he following aspects. Remarks Simple string for identifying a parameter Full name of the parameter NEs on which the parameter is set Commands for setting the parameter, and optional/mandatory attribute of the parameter in each command Functions, functioning ways, and protocols of the parameter Relevant feature ID Features using the parameter Parameter value type Parameter value range displayed on the GUI Actual parameter value range corresponding to the GUI Value Range. For example, the GUI Value Range is 0, and the corresponding Actual Value Range is OFF. Parameter value unit Initial value provided by the system Values recommended in different scenarios Parameter impact scope, that is, objects specified when the parameter is set Relationship between this parameter and other parameters. For example, to use this parameter, you need to set related switches and parameters. Whether this parameter is read/write or read only Whether modifying the parameter value may interrupt the existing services Possible interruption scope in the case that modifying the parameter value may interrupt the existing services Possible interruption duration in the case that modifying the parameter value may interrupt the existing services Cautions to be taken during the modification Requirements on how to validate the modification of the parameter. For example, you may need to reset the device to validate the modification. Impact of the radio parameter on the network performance

Version in which this parameter is introduced Whether this parameter is a radio parameter, a transport parameter, or an equipment parameter

Paramete Paramete NE r ID r Name

MML Feature Comman Meaning ID d

Feature Name

Value Type

GUI Value Range

Downlink quality level Downlink threshold Quality SET for the Threshold ABCDow GCELLH MS to be GBFDin BSC6900 nQuality OAD(Opti assigned 110502 Assigning onal) with a Better channel Cell of the better cell. Uplink quality level Uplink threshold Quality SET for the Threshold ABCUpQ GCELLH MS to be GBFDin BSC6900 uality OAD(Opti assigned 110502 Assigning onal) with a Better channel Cell of the better cell.

Assignme nt and Immediat Interval e Type Assignme nt

0~70

Assignme nt and Immediat Interval e Type Assignme nt

0~70

The maximum duration for the BSC to select the best cell according to MRs in the MS assigning procedure . The Maximum SET BSC Better ABCWait GCELLH assigns GBFDCell BSC6900 MaxTime OAD(Opti the 110502 Assigning onal) channel Duration of the serving cell to the MS if the best cell is not selected within the duration specified by this parameter . Whether to enable the BTS to support bypass ADD function. GBFDBSC6900 BTS(Opti HDLC 116601 onal) BTS and IP BTS do not support this parameter

Assignme nt and Immediat Interval e Type Assignme nt

10~80

ABISBYP Abis ASSMOD ByPass E Mode

Abis Bypass

TRUE(Su pport), Enumerati FALSE(N on Type ot Support)

Whether to permit Abis flow control. The flow control function helps in better call managem ent. If congestio n occurs, the SDCCH system SET Congestio lightens ABISFCE GCELLC GBFDn Flow BSC6900 its load by N CCH(Opti 111705 Control rejecting onal) Allowed some services or prolongin g the time for service requests. The Abis flow control is used to lighten the system

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

Used along with "Abis Flow Control Timer 2" to control the change in cell flow control levels.Wh en the flow control level in Abis Flow SET AbisFCTi GBFDthe cell Control BSC6900 BSCTMR( mer1 changes, 111705 Timer 1 Optional) the values of MS MAX Retrans and Txinteger in the system informatio n are changed accordingl y. When immediat e

GSM Flow Control

Interval Type

10~255

Used along with "Abis Flow Control Timer 1" to control the change in cell flow control levels.Wh en the flow control level in Abis Flow SET AbisFCTi GBFDthe cell Control BSC6900 BSCTMR( mer2 changes, 111705 Timer 2 Optional) the values of MS MAX Retrans and Txinteger in the system informatio n are changed accordingl y. When immediat e

GSM Flow Control

Interval Type

10~255

Abis Idle ABISIDLE TS TSALLOC Allocate Strategy

This parameter controls the strategy SET for idle BTSOTH GBFDBSC6900 timeslot PARA(Op 114201 selection tional) and optimizati on by the PS channels.

EGPRS

IDLETSA LLOC_0( Any idle timeslots under the same site), IDLETSA LLOC_1(I dle timeslots on same E1 Enumerati primary on Type link preferred) , IDLETSA LLOC_2(I dle timeslots on same E1 primary link only), IDLETSA LLOC_3(I

This parameter controls whether the strategy for timeslot configurat ion and optimizati on is started. When this parameter Abis Idle SET is set to ABISIDLE TS BTSOTH ON, the GBFDTSCFGS BSC6900 Configure PARA(Op bundled 114201 WITCH Switch tional) idle timeslots for the PS channel should be allocated to the same 64 kbit/s timeslot as the primary link. When this parameter is set to Threshold for enabling the BTS local switching. When the Abis Jam congestio AbisJamT Rate for SET n rate at GBFDhreshold2 BTS BSC6900 BSSLS(O the Abis 117702 StartLs Local ptional) interface Switch exceeds this threshold, the BTS local switching is enabled.

EGPRS

CLOSE(C Enumerati LOSE), on Type OPEN(O PEN)

BTS Local Switch

Interval Type

0~100

ABISRES TCHH ADJTCH Function HFUNSW Switch

This parameter specifies whether to enable the Abis resource adjustme nt TCHH function. It specifies whether the TCHH is SET preferenti BTSFLEX GBFDally BSC6900 ABISPAR allocated 117301 A(Optiona to the MS l) by the BSC6900, when Abis resources are insufficien t. If the Abis resource load is greater than "Flex Abis Prior Choose

Flex Abis

NO(NO), Enumerati YES(YES on Type )

Interval between detection of the Abis timeslot being in idle state and releasing of the Abis timeslot. When channels Timer of SET are idle, ABISTSF Releasing GCELLP the timer GBFDBSC6900 REETM Abis SCHM(O is started. 113101 Timeslot ptional) When the timer is expires, the Abis timeslot is released. When all the TBFs on the channel are released, the Abis timeslot is not released

PDCH Dynamic Interval Adjustme Type nt

10~3600

AbisVer

Abis Interface Tag

Phase tag for GSM SET protocols BSCBASI MRFDBSC6900 that the C(Optiona 210301 Abis l) interface supports

GSM_PH ASE_1, Configura GSM_PH tion Enumerati ASE_2, Managem on Type GSM_PH ent ASE_2Plu s

Duration available Duration for the of BTS BTS to ADD ABLASTT Collecting collect the GBFDBSC6900 AISSCFG IME AB[100 AB after 118201 (Optional) Millisecon the TRX d] or channel is activated.

SoftSynchroni Interval zed Type Network

1~255

Mean opinion score (threshold ) for judging an abnormal call. The BTS computes the MOS of a call periodicall y and Abnormal SET reports Abnormal Voice OTHSOF the call MosThres BSC6900 MOS TPARA(O MOS to hold Threshold ptional) the BSC in custom measure ment reports. According to the call MOS, the BSC checks whether the call is normal. If the call MOS is less than Access pulse type of the PRACH, uplink PTCCH and packet control SET Access acknowle ACCBUR GCELLP Burst BSC6900 dge ST SBASE(O Type message ptional) of the MS. 8bit: 8 bit pulse access mode; 11bit: 11 bit pulse access mode.

GBFD116801

Voice Quality Index (Uplink VQI)

Interval Type

0~250

GBFD119110

Access

8BIT(8BIT Enumerati ), on Type 11BIT(11 BIT)

ACCCON Access TROLCL Control ASS Class

SET GCELLP BSC6900 RACH(Op tional)

Access control class of the MS When the cell supports Repeated This parameter specifies whether the access control function is enabled in a cell. When the function is enabled, the BSC determine s which MSs in the cell to be connecte d to the network by sending the ACC classes through system message s This parameter specifies the index of the access control policy that is used in a cell.

GBFD119110

Access

Interval Type

0~65535

Access ACCCTR Control LEN Allowed

SET GCELLC BSC6900 CBASIC( Optional)

GBFD511002

Enumerati NO(No), on Type YES(Yes)

Access ACCCTR Control LPY Policy

SET GCELLC BSC6900 CBASIC( Mandator y)

GBFD511002

Interval Type

0~31

IncomingSET to-BSC ACCESS GCELLH HO BSC6900 OPTILAY OIUO(Opt Optimum ional) Layer

Access ACCINDE Control X Policy Index

ADD BSCACC BSC6900 CTRLP(M andatory)

Subcell preferred during the incoming inter-BSC handover to the concentric cell. In the case of incoming inter-BSC handover to the concentric cell, the channels in this subcell are preferred. This parameter specifies the index of an access control (ACC) policy. It is used to identify an ACC policy.

GBFD113201

OSubcell( Overlaid subcell), USubcell( Concentri Enumerati Underlaid c Cell on Type subcell), NoPrefer( No preferenc e)

GBFD511002

Interval Type

0~31

PS Initial AccStaSe Access rviceType Service Type

SET GCELLP BSC6900 SOTHER PARA(Op tional)

Whether the initial service is GBFDuplink, 119501 downlink or neutral

Starting Point of ACCWPO the S Access Control Window

This parameter is used to specify the ADD starting BSCACC GBFDBSC6900 point of CTRLP(O 511002 the ACC ptional) sliding window in an access control policy.

ULPRIOR ITY(Uplin Adaptive k Priority), Adjustme NEUTRA nt of Enumerati L(Neutral Uplink on Type Priority), and DLPRIOR Downlink ITY(Down Channels link Priority)

Interval Type

0~9

Access ACCWSI Control ZE Window Size

ADD BSCACC BSC6900 CTRLP(O ptional)

Sliding Speed of ADD the BSCACC ACCWSP BSC6900 Access CTRLP(O Control ptional) Window

This parameter is used to specify the ACC sliding window size in an access control policy. MSs of the ACC access classes that are specified in the sliding window are not allowed to access the This parameter is used to specify the sliding speed of the ACC sliding window in an access control policy.

GBFD511002

Interval Type

1~10

GBFD511002

Interval Type

15~7200

ACFC

ADD Address PPPLNK( and Optional) control BSC6900 ADD field MPGRP( compress Optional)

ACFC

ADD BTSPPPL NK(Optio nal) Support ADD Address BTSMPG and RP(Optio Control BSC6900 nal) Field IMP Compres BTSPPPL s NK(Optio nal) IMP BTSMPG RP(Optio

Whether to compress the address and control fields. If this parameter is set to ENABLE, the address and control area compress ion is enabled. If this parameter is set to DISABLE, the address and control area

GBFD118611 GBFD118622

Abis IP Disable(D over Enumerati isable), E1/T1 on Type Enable(E A IP over nable) E1/T1

A flag bit indicates Whether to support the GBFDcompress 118611 ion of the address and control fields.

Abis IP over E1/T1

Enumerati NO(No), on Type YES(Yes)

This parameter specifies whether to receive the CS paging request from A interface when the MS uses a PS service. A This SET ACOOPE Interface parameter BSCPSS RATPAGI Paging is used to GBFDBSC6900 OFTPAR NGSWIT Co119305 control A(Optiona CH ordination the l) Switch paging collaborati on function of A interface of the entire BSC. This parameter specifies whether to forward the paging

BSS CLOSE(C Paging Enumerati lose), Coordinati on Type OPEN(Op on en)

ACS

Used for notifying MSs where to retrieve relevant parameter s during cell reselectio n. The default value of this Additional SET parameter Reselect GCELLID is 0 in Paramete BSC6900 LEAD(Opt system r ional) message Indication 3 and, has no special significan ce. In system message 4, if the value of this parameter is 0, it means that the MSs must

GBFD110402 GBFD111101

COMPUL Basic Cell 0(Compul Resory 0), selection Enumerati COMPUL System on Type 1(Compul Informatio sory 1), n Sending FLEX(Fle xible)

ACTCDS AMR ETF ACS[F]

Active coding set (ACS)[F], indicates a set of full-rate coding rates currently available for calls. The AMR is a set of multiple SET speech GCELLC BSC6900 coding CAMR(O and ptional) decoding rates. Modifying the default coding rates will affect speech quality when TrFO or TFO is in use.

GBFD115501 GBFD115701

AMR FR TFO

Bit Field Type

4_75KBIT /S~0 5_15KBIT /S~1 5_90KBIT /S~2 6_70KBIT /S~3 7_40KBIT /S~4 7_95KBIT /S~5 10_2KBIT /S~6 12_2KBIT /S

ACTCDS AMR ETH ACS[H]

Active coding set (ACS)[H], indicates set of halfrate coding rates currently available for calls. The AMR is a set of multiple SET GBFDspeech GCELLC 115502 BSC6900 coding CAMR(O GBFDand ptional) 115701 decoding rates. Modifying the default coding rates will affect speech quality when TrFO or TFO is in use.

AMR HR TFO

Bit Field Type

4_75KBIT /S~0 5_15KBIT /S~1 5_90KBIT /S~2 6_70KBIT /S~3 7_40KBIT /S~4 7_95KBIT /S

Active coding set (ACS)[W B], indicates a set of wideband coding rates currently available for calls. The AMR is a set of SET multiple ACTCDS AMR GCELLC BSC6900 speech ETWB ACS[WB] CAMR(O coding ptional) and decoding rates. Modifying the default coding rates will affect speech quality when TrFO or TFO is in use.

GBFD115507 GBFD115701

WB AMR Bit Field TFO Type

6_60KBIT /S, 8_85KBIT /S, 12_65KBI T/S

Whether to activate the function of L2 reestablish ment. If this function is activated, the BSC starts the attempt of L2 reestablish Activate SET ment ACTL2RE L2 ReGCELLS when the BSC6900 EST establish OFT(Opti BSC ment onal) receives an ERR IND message reported by the BTS in a conversati on of MSs. If the L2 reestablish ment succeeds, the conversati Valid Valid duration Time of ADD of the ACTTIME BTS BSC6900 AISSCFG reserved Resource (Optional) TRX or Activation timeslot

GBFD110501 GBFD510502

Call Control Handover Enumerati NO(No), Reon Type YES(Yes) establish ment

GBFD118201

SoftSynchroni Interval zed Type Network

1~255

ACVLTH D

AC voltage alarm lower threshold. When the input AC voltage is lower than the value of this parameter , an alarm indicating AC SET the Voltage BTSAPM abnormal GBFDBSC6900 Lower UBP(Opti AC is 111202 Threshold onal) reported. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding BTS The

O&M of BTS

Interval Type

60~300

reports an alarm if AC SET the AC ACVOLA Overvolta BTSDPM voltage GBFDBSC6900 LARMH ge Alarm UBP(Opti exceeds 111202 Threshold onal) the value of this parameter . The BTS reports an alarm if AC SET the AC ACVOLA Undervolt BTSDPM voltage is GBFDBSC6900 LARML age Alarm UBP(Opti lower 111202 Threshold onal) than the value of this parameter

O&M of BTS

Interval Type

610~3000

O&M of BTS

Interval Type

600~2990

The BTS reports an alarm if the AC voltage exceeds the value of the AC voltage alarm upper threshold. When the input AC voltage is AC SET higher ACVUTH Voltage BTSAPM than the GBFDBSC6900 D Upper UBP(Opti value of 111202 Threshold onal) this parameter , an alarm indicating the abnormal AC is reported. In multimode scenario, the value of this parameter must be the same Whether to hand over an MS to Assignme another nt SET channel ADAPTA Procedur GCELLS during an SSIGNME BSC6900 e in IntraOFT(Opti intra-cell NTFLOW Cell HO onal) handover Allowed through the assignme nt process

O&M of BTS

Interval Type

60~300

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

Communi cation address of the CBUS3 on the bus 485. The configurat ion of this parameter ADDR must be consistent with the actual physical connectio n. Otherwise , the board may not Interval for requestin Sub-Link g the Bandwidt SET bandwidth h Request BSCPSS AddTrans for the Interval BSC6900 OFTPAR BwInt secondar When Not A(Optiona y link Congeste l) when the d system is not in congestio Bandwidt SET BTSFMU ABP(Opti onal) SET BTSAPM UBP(Opti onal) SET Communi BTSDAT cation BSC6900 UBP(Opti Address onal) SET BTSDEM UBP(Opti onal) SET BTSDHE UBP(Opti onal)

GBFD111202

O&M of BTS

Interval Type

0~254

GBFD111705

GSM Flow Control

Interval Type

0~50

h Bandwidt requested h for SET each time Secondar BSCPSS for the AddTrans GBFDy Link BSC6900 OFTPAR secondar BwNum 111705 When Not A(Optiona y link Congeste l) when the d system is not in congestio

GSM Flow Control

Interval Type

0~768

ADEF

Whether to enable each AC RRU external alarm port's customer definition switch. "0" indicates that the external alarm External SET port's Alarm BTSRXU customer GBFDCustomer BSC6900 BP(Optio definition 111202 Definition nal) switch is Switch disabled and this port is not defined by customor but by vendor, and "1" indicates that the external alarm port's The ADD EXTNCE LL(Manda Adjacent tory) BSC6900 BSC DPC COL BSCSYN CINFO(M andatory) destinatio n signaling point (DSP) of the adjacent BSC must be an Iurg DSP. Whether to adjust the BTS offset manually or automatic ally

O&M of BTS

Bit Field Type

PORT0_ CDEF, PORT1_ CDEF

ADJBSC DPC

GBFD111804

A Interface Protocol Process

Interval Type

1~167772 15

SET BTSEXC URSION( Mandator ADJMOD Adjustme BSC6900 y) E nt Mode SET BSCSYN COFF(Ma ndatory)

GBFD118201

BYMANU SoftAL(By Synchroni Enumerati Manual), zed on Type BYAUTO( Network By Auto)

Support EGPRS ADJUST Uplink ULMCST MCS YPE Dynamic Adjust

Mode of dynamical ly adjusting the EGPRS uplink encoding scheme. Value 0 indicates dynamic adjustme nt of EGPRS SET uplink GCELLE GBFDcoding BSC6900 GPRSPA scheme is 119204 RA(Optio not nal) supported ; value 1 indicates that the uplink coding scheme is adjusted according to downlink quality measure ments

0(Not support dynamic adjustme nt), 1(Accordi ng to downlink Dynamica quality lly measure Adjusting Enumerati ments the Uplink on Type reported MCS by MS), Coding 2(Accordi ng to uplink quality measure ments reported by BTS)

This parameter specifies whether to enable automatic autoloading and autoactivation of the BTS software. If this parameter Auto SET is set to Download BTSAUT ADLDAC Yes, the GBFDActive BSC6900 ODLDAC T 111202 BTS Function TINFO(O software Switch ptional) is automatic ally loaded and activated when the BTS is initialized or a board is added; the TMU software is automatic

O&M of BTS

Enumerati OFF(OFF on Type ), ON(ON)

This parameter specifies the automatic load mode of the BTS software. If this parameter is set to common download, common SET loading is Auto BTSAUT performe GBFDADMODE Download BSC6900 ODLDAC d on the 111202 Mode TINFO(O OML/EML ptional) , and the link is not extended. If this parameter is set to quick download (without traffic), quick loading can be performe d on the SET Administr GCELLA Administr ADMSTA GBFDative BSC6900 DMSTAT( ative state T 111202 State Mandator of a cell y)

O&M of BTS

COMMO N_DLD(C ommon Download ), QUICK_D LD1(Quic k Enumerati Download on Type No Traffic), QUICK_D LD2(Quic k Download Reserve BCCH)

O&M of BTS

LOCK(Lo ck), UNLOCK( Enumerati Unlock), on Type SHUTDO WN(Shut down)

SET Administr ADMSTA GTRXAD ative BSC6900 T MSTAT(M State andatory)

Administr ative state GBFDof the 111202 TRX

O&M of BTS

Lock(Loc k), Unlock(U Enumerati nlock), on Type Shutdown (Shutdow n)

SET Administr GTRXCH ADMSTA ative BSC6900 ANADMS T State TAT(Man datory)

Administr ative state GBFDof the 111202 channel

O&M of BTS

Lock(Loc k), Unlock(U Enumerati nlock), on Type Shutdown (Shutdow n)

ADTET

Offset End time Time ADD for GBFDAdjustme BSC6900 AISSCFG adjusting 118201 nt End (Optional) the offset Time time

SoftSynchroni Compoun hour, min zed d Type Network

Cell load threshold for adjusting the offset Load time. If Threshold ADD the load GBFDADTLOD of Offset BSC6900 AISSCFG threshold 118201 Adjustme (Optional) is nt exceeded , the offset time is not adjusted.

SoftSynchroni Interval zed Type Network

0~100

ADTON

Offset ADD Offset Time AISSCFG Time GBFDBSC6900 Adjustme (Mandator Adjustme 118201 nt Switch y) nt Switch

SoftSynchroni Enumerati OFF(OFF zed on Type ), ON(ON) Network

ADTST

Offset Start time Time ADD for GBFDAdjustme BSC6900 AISSCFG adjusting 118201 nt Start (Optional) the offset Time time

SoftSynchroni Compoun hour, min zed d Type Network

Advanced ADD Advanced ADVALM Alarm BTSALM alarm MRFDMGRULE Managem BSC6900 MGMRUL managem 210304 TP ent Rule E(Mandat ent rule Type ory) type This parameter specifies the software version 1 that is automatic ally loaded and activated. The version of the BTS SET software BTS BTSAUT stored on GBFDADVER1 Software BSC6900 ODLDAC the OMU 111202 Version 1 TINFO(O must be ptional) consistent with this version number. Otherwise ,a software version inconsiste ncy alarm is reported. An example of the

Faulty RATIORU Enumerati Managem LE(Ratio on Type ent Rule)

O&M of BTS

String Type

None

SET BTS BTSAUT ADVER2 Software BSC6900 ODLDAC Version 2 TINFO(O ptional)

AEC AEC_Ech Echo o_Path_D Path elay Delay

SET BSC6900 TCPARA( Optional)

This parameter specifies the software version 2 that is automatic ally loaded and activated. The BTS software stored on the OMU must be consistent with this version number. Otherwise , the software version inconsiste ncy alarm may be reported. An example of the version format is If the echo path is traced, the echo is judged and controlled according to the trace result of the echo path parameter s. Otherwise , the echo is judged and controlled according to the

GBFD111202

O&M of BTS

String Type

None

GBFD115602

Acoustic Echo Interval Cancellati Type on(AEC)

0~600

AEC AEC_Ech Echo o_Return Return _Loss Loss

SET BSC6900 TCPARA( Optional)

AEC_Nlp AEC Nlp _Gate Gate

SET BSC6900 TCPARA( Optional)

This parameter is used for echo judgment and control when the echo parameter s are not traced. If the local input voltage is lower than the value of this parameter and the remote end transmits the voice signal, the AEC function uses the comfort noise to replace the minor echo. In this case, the speech signals at low level

GBFD115602

Acoustic Echo Interval Cancellati Type on(AEC)

0~60

GBFD115602

Acoustic Echo Interval Cancellati Type on(AEC)

-60~-35,0

Extra delay due to the transmissi on line. This parameter should be SET AEC_Pat AEC Path set GBFDBSC6900 TCPARA( h_Delay Delay according 115602 Optional) to the actual conditions and is applicable to satellite transmissi on.

Acoustic Echo Interval Cancellati Type on(AEC)

0~1000

SET AEC_SN AEC SNR BSC6900 TCPARA( R_Gate Gate Optional)

AEC_Swit AEC ch Switch

SET BSC6900 TCPARA( Optional)

This parameter is used to determine whether there are speech signals at the local end. If the local SNR is lower than the value of this parameter , echo control is not performe d. This parameter indicates whether the acoustic echo cancellati on (AEC) functional switch is on or off.

GBFD115602

Acoustic Echo Interval Cancellati Type on(AEC)

0~15

GBFD115602

Acoustic CLOSE(C Echo Enumerati lose), Cancellati on Type OPEN(Op on(AEC) en)

Threshold for AECDete AEC SET detecting GBFDctThresho Detect BSC6900 TCPARA( the AEC 115602 ld Threshold Optional) performa nce

Acoustic Echo Interval Cancellati Type on(AEC)

10~100

AEC AECDete Detect ctTime Time

Time for SET detecting GBFDBSC6900 TCPARA( the AEC 115602 Optional) performa nce

Acoustic Echo Interval Cancellati Type on(AEC)

1~10

AFR AFRDSB Radio LCNT Link Timeout

Counter for radio link failures during an AMR full SET rate call. GCELLC See the GBFDBSC6900 CBASIC( descriptio 115505 Optional) n of "Radio Link Timeout" in "SET GCELLC CBASIC".

AMR Wireless Link Timer

4_Times, 8_Times, 12_Times , 16_Times , 20_Times , 24_Times , 28_Times , 32_Times , Enumerati 36_Times on Type , 40_Times , 44_Times , 48_Times , 52_Times , 56_Times , 60_Times , 64_Times

AFR AFRSAM SACCH ULFRM MultiFrames

Number of SACCH multifram es during an AMR full rate SET call. See GCELLC GBFDBSC6900 the CBASIC( 115505 descriptio Optional) n of "SACCH MultiFrames" in "SET GCELLC CBASIC".

AMR Wireless Link Timer

Interval Type

0~63

AGPSRE CEIVERI GPS ID D

ADD GPS BSC6900 GPS(Man receiver datory) ID

MRFD210502

BSC/RNC Interval Clock Type

0~65534

AGPSRE ADD GPS CEIVERT GPS type BSC6900 GPS(Man receiver YPE datory) type.

MRFD210502

BSC/RNC Enumerati BSC(BSC Clock on Type )

AHR AHRDSB Radio LCNT Link Timeout

Counter for radio link failures during an AMR half SET rate call. GCELLC See the GBFDBSC6900 CBASIC( descriptio 115505 Optional) n of "Radio Link Timeout" in "SET GCELLC CBASIC".

AMR Wireless Link Timer

4_Times, 8_Times, 12_Times , 16_Times , 20_Times , 24_Times , 28_Times , 32_Times , Enumerati 36_Times on Type , 40_Times , 44_Times , 48_Times , 52_Times , 56_Times , 60_Times , 64_Times

AHR AHRSAM SACCH ULFRM MultiFrames

Number of SACCH multifram es during an AMR half rate SET call. See GCELLC GBFDBSC6900 the CBASIC( 115505 descriptio Optional) n of "SACCH MultiFrames" in "SET GCELLC CBASIC".

AMR Wireless Link Timer

Interval Type

0~63

AID

Alarm ID

SET ALMPOR BSC6900 Alarm ID T(Mandat ory)

MRFD210304

Faulty Interval Managem Type ent

65334~65 383

AID

Alarm ID

SET ALMBLKP BSC6900 Alarm ID ARA(Man datory) SET ALMLVL( Mandator y) SET BSC6900 ALMSHL D(Mandat ory) SET BOXRPT(

MRFD210304

Faulty Interval Managem Type ent

1~65535

AID

Alarm ID

Identifier of the alarm. This MRFDparameter 210304 uniquely identifies an alarm.

Faulty Interval Managem Type ent

1~65535

AID

Alarm ID

Identifier of the ADD alarm. OBJALM This MRFDBSC6900 SHLD(Op parameter 210304 tional) uniquely identifies an alarm. Identifier SET ENVALM BSC6900 PARA(Ma ndatory) of the alarm. MRFDThis parameter 210304 uniquely identifies an alarm.

Faulty Interval Managem Type ent

1~65535

AID

Alarm ID

Faulty Interval Managem Type ent

1~65535

AID

SET BTSENV Alarm ID. BSC6900 ALMPOR Alarm ID T(Optiona l)

GBFD111202

O&M of BTS

Interval Type

65033~65 533

AID

ADD BTSOBJA Alarm ID. BSC6900 LMSHLD( Alarm ID Mandator y)

MRFD210304

Faulty String Managem Type ent

None

Aiding AIDDELA Delay YPROTE Protect CTTIME Time

Delay time for mutualaid detection on a cell after the cell is initialized. When the cell initializati on has just SET finished, GCELLS GBFDBSC6900 the cell is OFT(Opti 113801 in an onal) unstable state. Mutualaid detection at this time may cause a wrong decision. Therefore , this parameter is used ADD Type of OBJALM MRFDBSC6900 alarm SHLD(Op 210304 selection tional)

TRX Interval Cooperati Type on

1~60

AIDST

Alarm Select Type

ALL(All), Faulty Enumerati ONEBYO Managem on Type NE(One ent by One)

AIDST

Alarm Select Type

ADD BTSOBJA Alarm MRFDBSC6900 LMSHLD( selection 210304 Mandator mode y)

ALL(all), Faulty Enumerati ONEBYO Managem on Type NE(one ent by one)

A Interface SET AInterMsg Msg OTHSOF BSC6900 Trace [End2end TPARA(M User andatory) Tracing]

A IF FC AINTFFC Discard DISCLUE LOC UP N Enable

SET BSCFCP BSC6900 ARA(Opti onal)

Whether to trace Ainterface message s during end-toend user tracing. The endto-end tracing is conducte d throughou t the network. The Ainterface tracing results can be obtained from the MSC or Whether to allow flow control for the location update services during the A interface whether

GBFD116401

End-toEnd MS Enumerati NO(No), Signaling on Type YES(Yes) Tracing

GBFD111705

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

A IF FC AINTFFC Discard DISCMO MOC CEN Enable

to allow flow SET control for BSCFCP the GBFDBSC6900 ARA(Opti mobile111705 onal) originated services during the A Whether to allow flow SET control for BSCFCP the GBFDBSC6900 ARA(Opti mobile111705 onal) terminate d services during the A

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

A IF FC AINTFFC Discard DISCMTC MTC EN Enable

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

A IF FC AINTFFC Discard DISCOSE Other N Service Enable

Whether to allow flow control for the other services SET including BSCFCP GBFDBSC6900 emergenc ARA(Opti 111705 y call, call onal) reestablish, and LMU services during the A Whether to enable the A interface flow control mechanis m in the Flow control method used by the BSC6900. Flow control method at the Abis interface: When receiving a channel request SET message, BSCFCP the BSC6900 ARA(Opti BSC6900 onal) begins flow control on the call according to the flow control level of the A interface. Flow control method at the A interface: When SET BSCFCP BSC6900 ARA(Opti onal)

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

A Interface AINTFFC Flow EN Control Enable

GBFD111705

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

A Interface AINTFFC Flow METHOD Control Method

GBFD111705

GSM Flow Control

Enumerati ABIS(Abis on Type ), A(A)

A IF FC AINTFFC Service RSRATE Rate in 1 Level 1

Rate of discarded SET services BSCFCP in level 1 GBFDBSC6900 ARA(Opti of the A 111705 onal) interface flow control Rate of SET BSCFCP BSC6900 ARA(Opti onal) discarded services in level 2 GBFD111705 of the A interface flow control Rate of discarded services in level 3 GBFD111705 of the A interface flow control Rate of discarded services in level 4 GBFD111705 of the A interface flow control Rate of discarded services in level 5 GBFD111705 of the A interface flow control Rate of discarded services in level 6 GBFD111705 of the A interface flow control

GSM Flow Control

Interval Type

0~100

A IF FC AINTFFC Service RSRATE Rate in 2 Level 2

GSM Flow Control

Interval Type

0~100

A IF FC AINTFFC Service RSRATE Rate in 3 Level 3

SET BSCFCP BSC6900 ARA(Opti onal)

GSM Flow Control

Interval Type

0~100

A IF FC AINTFFC Service RSRATE Rate in 4 Level 4

SET BSCFCP BSC6900 ARA(Opti onal)

GSM Flow Control

Interval Type

0~100

A IF FC AINTFFC Service RSRATE Rate in 5 Level 5

SET BSCFCP BSC6900 ARA(Opti onal)

GSM Flow Control

Interval Type

0~100

A IF FC AINTFFC Service RSRATE Rate in 6 Level 6

SET BSCFCP BSC6900 ARA(Opti onal)

GSM Flow Control

Interval Type

0~100

CSD(Circ uit Switched Data) service redundan cy level, CSD SET which is AIPCSDS Service BSCBASI configure GBFDRVRDND BSC6900 Redunda C(Optiona d to 118602 LEV ncy Level l) decrease the data loss rate during transmissi on in A over IP mode. Fixed SET gain value GBFDBSC6900 TCPARA( in fixed 115601 Optional) gain mode

NO(Not Supporte d), R3(Only R3 Supporte d), Enumerati R2(Only A over IP on Type R2 Supporte d), R2ANDR 3(R2 And R3 Supporte d)

ALC_Fix_ ALC Fix Gain Gain

Automatic Level Interval Control Type (ALC)

-12~12

ALC_Fix_ ALC Fix Target_Le Target vel Level

Target SET level in GBFDBSC6900 TCPARA( fixed level 115601 Optional) mode

Automatic Level Interval Control Type (ALC)

-23~-4

This parameter restrains the maximum gain to the input signal. It is valid only when "ALC Mode" is SET ALC_Max ALC Max "FIXEDLE GBFDBSC6900 TCPARA( _Gain Gain 115601 VEL" or Optional) "ADAPTI VE". If the parameter is set to a small value, it may affect the conforma nce to the target level. Maximum target ALC_Max ALC Max SET level in GBFD_Target_L Target BSC6900 TCPARA( adaptive 115601 evel Level Optional) ALC mode

Automatic Level Interval Control Type (ALC)

3~12

Automatic Level Interval Control Type (ALC)

-23~-4

ALC_Min ALC Min _Target_L Target evel Level

Mimumu m target SET level in BSC6900 TCPARA( adaptive Optional) ALC mode

GBFD115601

Automatic Level Interval Control Type (ALC)

-23~-4

ALC_Mod ALC e Mode

SET ALC level GBFDBSC6900 TCPARA( control 115601 Optional) mode

FIXEDLE VEL(Fixe d level mode), Automatic ADAPTIV Level Enumerati E(Adaptiv Control on Type e mode), (ALC) FIXEDGA IN(Fixed gain mode)

ALC_Swit ALC ch Switch

Whether to enable the SET adaptive GBFDBSC6900 TCPARA( level 115601 Optional) control (ALC) function

Automatic CLOSE(C Level Enumerati lose), Control on Type OPEN(Op (ALC) en)

ALIVERE Alive TRY Retry

SET BSCNSP BSC6900 ARA(Opti onal)

ALIVETIM Alive ER Timer

SET BSCNSP BSC6900 ARA(Opti onal)

Retry times after the timer for the reply from the peer expires during the NSVC live test. If the reply is not received after the system resends the message according to retry times, the NSVC is regarded Duration of the timer to wait for the reply from the peer during the NSVC live

GBFD510002

Gb Over FR

Interval Type

5~15

GBFD510002

Gb Over FR

Interval Type

1~255

AllBw

Specifies the bandwidth occupied when the " transmissi ADD on Bandwidt RSCGRP GBFDBSC6900 resource h (Mandator 118605 group y) type " is IP and the " bandwidth mode " is HALF_DU PLEX.

IP QOS

Interval Type

0~400000 0

Whether Resource SET to Reallocati BSCPSS reassign ALLOCDI on to BSC6900 OFTPAR the TBF FFTRX Different A(Optiona for a Trx l) different Trx

GBFD114101

GPRS

NOTALL OW(Not Enumerati Allow), on Type ALLOW(A llow)

ALLOCSI NGLEPD CHFORSI GNALLIN G

Allocate SET One GCELLP PDCH for BSC6900 SCHM(O Signaling ptional) Data

SET ALLOWA GCELLC MRHALF Ratio of BSC6900 HMGBASI RATEUS AMR-HR C(Optiona ERPERC l)

When this parameter is set to ON, the GMM/SM signaling service is assigned only one PDCH; otherwise, the GMM/SM signaling service is assigned one or more PDCHs as required. Maximum ratio of the number of AMR half rate channels to the total number of channels in a cell. When the resource allocation principle is determine d by the BSC, no AMR half rate channel can be further assigned if the ratio of the number of AMR half rate channels to the total

GBFD113101

PDCH Dynamic Enumerati OFF(OFF Adjustme on Type ), ON(ON) nt

GBFD111005

Enhanced Channel Interval Assignme Type nt Algorithm

0~100

ALLOWE Allow DADAMU EDA LTIPLEX Multiplex

SET BSCPSS BSC6900 OFTPAR A(Optiona l)

Allowed ALLOWE Measure DMEASR Report PTMISSE Missed DNUM Number

SET GCELLN BSC6900 C2PARA( Optional)

Whether to allow EDA multiplex. "Not Allow": the TBF of the EDA cannot be multiplexe d with other TBR; "Allow": the TBF of the EDA can be Number of allowed measure report missed. If the number of allowed measure report missed exceeds this value, the previous measure report is invalid.

GBFD119401

EDA(Exte NOTALL nded OW(Not Enumerati Dynamic Allow), on Type Allocation ALLOW(A ) llow)

GBFD116201

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~16

ALLOWH ALFRATE Ratio of USERPE TCHH RC

SET GCELLC BSC6900 HMGBASI C(Optiona l)

ALLTSTY Timeslot PE Type

ADD BSC6900 AE1T1(M andatory)

Maximum ratio of the number of half rate channels to the total number of channels in a cell. When the resource allocation principle is determine d by the BSC, no half rate channel can be further assigned if the ratio of the number of half rate channels to the total number of channels in the cell Value ALLCIC indicates that all E1/T1 timeslots on the A interface must be set with the start CIC. Value ALLNULL indicates that all E1/T1 timeslots on the A interface can be set with the value NULL.

GBFD111005

Enhanced Channel Interval Assignme Type nt Algorithm

0~100

GBFD111803

ALLCIC(S et all A Timeslots Interface Enumerati CIC), Circuit on Type ALLNULL Managem (Set all ent Timeslots Null)

ALLTSTY Timeslot PE Type

ADD BSC6900 PBE1T1( Optional)

ALMD0

Feed Tri. 0 TMA SET Low BTSDAT BSC6900 Current UBP(Opti Alarm onal) Threhold

ALMD1

Feed Tri. 1 TMA SET Low BTSDAT BSC6900 Current UBP(Opti Alarm onal) Threhold

Value ALLCIC indicates that all E1/T1 timeslots on the PB interface must be set with the start CIC. Value ALLNULL indicates that all E1/T1 timeslots on the PB interface can be set with the value NULL. If the feed current of the TMA on tributary 0 is smaller than the value of this parameter , the TMA Low Temperat ure alarm is triggered. If the feed current of the TMA on tributary 1 is smaller than the value of this parameter , the TMA Low Temperat ure alarm is triggered.

GBFD111203

O&M of BSC

ALLCIC(S et all Timeslots Enumerati CIC), on Type ALLNULL (Set all Timeslots Null)

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

ALMD2

ALMD3

ALMD4

If the feed current of the TMA on tributary 2 Feed Tri. is smaller 2 TMA SET than the Low BTSDAT value of BSC6900 Current UBP(Opti this Alarm onal) parameter Threhold , the TMA Low Temperat ure alarm is triggered. If the feed current of the TMA on tributary 3 Feed Tri. is smaller 3 TMA SET than the Low BTSDAT value of BSC6900 Current UBP(Opti this Alarm onal) parameter Threhold , the TMA Low Temperat ure alarm is triggered. If the feed current of the TMA on tributary 4 Feed Tri. is smaller 4 TMA SET than the Low BTSDAT value of BSC6900 Current UBP(Opti this Alarm onal) parameter Threhold , the TMA Low Temperat ure alarm is triggered.

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

ALMD5

Feed Tri. 5 TMA SET Low BTSDAT BSC6900 Current UBP(Opti Alarm onal) Threhold

Alarm ADD Disappear BTSALM ALMDISA Accumula BSC6900 MGMRUL CDUR te E(Mandat Duration ory)

Alarm ALMENA Enable BLE Flag

SET BTSAPM UBP(Opti onal) BSC6900 SET BTSDPM UBP(Opti onal)

If the feed current of the TMA on tributary 5 is smaller than the value of this parameter , the TMA Low Temperat ure alarm is triggered. Accumula ted alarm clearance failure duration.T hreshold for the accumulat ed duration in which the alarm persists. If the accumulat ed duration exceeds this threshold, an alarm is cleared. Otherwise , the Whether the configurat ion of alarm parameter s is allowed. In multimode scenario, the value of this parameter must be the same as the value of the parameter

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

MRFD210304

Faulty Interval Managem Type ent

0~65535

MRFD210304

Faulty NO(NO), Enumerati Managem YES(YES on Type ent )

AlmId

SET BTSALMF ID of the MRFDAlarm ID. BSC6900 LASHTH intermitte 210304 D(Mandat nt alarm. ory)

Faulty Interval Managem Type ent

0~65534

ALMID

ADD BTSALM Alarm ID. BSC6900 MGMRUL Alarm ID E(Mandat ory) If the input current of the antenna feeder is smaller than the value of this parameter , an alarm related to the GPS antenna is If the input current of the antenna feeder is greater than the value of this parameter and "GPS or RGPS" is set to "GPS", an alarm related to the GPS antenna is

MRFD210304

Faulty Interval Managem Type ent

0~65535

ALMLMT Lower DOWN Alarm

SET BTSDGP BSC6900 SBP(Opti onal)

MRFD210304

Faulty Interval Managem Type ent

0~15

ALMLMT Upper UP1 Alarm

SET BTSDGP BSC6900 SBP(Opti onal)

MRFD210304

Faulty Interval Managem Type ent

45~155

ALMLMT Upper UP2 Alarm

SET BTSDGP BSC6900 SBP(Opti onal)

Alarm ADD Occurren BTSALM ALMOCA ce BSC6900 MGMRUL CDUR Accumula E(Mandat te ory) Duration

If the input current of the antenna feeder is greater than the value of this parameter and "GPS or RGPS" is set to "RGPS", an alarm related to the RGPS antenna is Accumula ted alarm occurrenc e duration.T hreshold for the accumulat ed duration in which the alarm persists. If the accumulat ed duration exceeds this threshold, an alarm is generated

MRFD210304

Faulty Interval Managem Type ent

125~175

MRFD210304

Faulty Interval Managem Type ent

0~65535

Alarm Occur Accumula tive Time refers to the percentag e of the alarm occurrenc e accumulat ive time to "Flash Statis Alarm SET Alarm AlmOccur Occur BTSALMF MRFDRaise AccuTime Accumula BSC6900 LASHTH 210304 Time HThd tive Time D(Optiona Window". Threshold l) If the alarm occurrenc e accumulat ive duration is greater than the parameter value, the BTS fault statistical alarm is reported.

Faulty Interval Managem Type ent

0~100

Alarm Clear Accumula tive Time refers to the percentag e of the alarm clearance accumulat ive time to "Flash Statis Alarm Alarm SET Clear AlmOccur Clear BTSALMF MRFDTime AccuTime Accumula BSC6900 LASHTH Window". 210304 LThd tive Time D(Optiona If the Threshold l) alarm clearance accumulat ive duration is greater than this threshold, the BTS fault statistical alarm is cleared. For example,

Faulty Interval Managem Type ent

0~100

If the number of alarm flashes exceeds the value of this parameter within the time specified by "Flash Statis SET Alarm Alarm AlmOccur BTSALMF Raise Occur MRFDTimesHT BSC6900 LASHTH Time Times 210304 hd D(Optiona Window", Threshold l) the BTS Statistical Alarm is generated . If this parameter is set to 0, the statistics of the BTS alarm flashes is not

Faulty Interval Managem Type ent

0~250

If the number of alarm flashes is smaller than the value of this parameter within the time specified by "Flash Statis SET Alarm Alarm AlmOccur BTSALMF Clear Clear MRFDTimesLTh BSC6900 LASHTH Time Times 210304 d D(Optiona Window", Threshold l) the BTS Statistical Alarm is cleared. If this parameter is set to 0, the statistics of the BTS alarm flashes is not collected. Whether the configurat ion of alarm parameter s is allowed. Alarm The value Paramete SET ALMPAR "YES" r BTSDHE MRFDACFGFL BSC6900 indicates Configura UBP(Opti 210304 AG that the tion onal) configurat Enabled ion is allowed, and the value "NO" indicates that the configurat

Faulty Interval Managem Type ent

0~250

Faulty NO(NO), Enumerati Managem YES(YES on Type ent )

ALMTP

Alarm Type

ALPHA

ALPHA

Type of the alarm. The alarm can be a fault alarm or an event alarm. It is used to perform open loop power control. Alpha parameter is used by the MS to calculate the output power PCH of the uplink PDCH. SET This GCELLP parameter BSC6900 SPWPAR is used to A(Optiona set the l) reduced class of the Tx power of the MS, in correspon dence with the path loss, when the GPRS dynamic power control is enabled. EXP ALMLOG( Optional) BSC6900 STA ALMLOG( Optional) SET GCELLLC BSC6900 S(Optiona l)

MRFD210304

Faulty flt(Fault), Enumerati Managem evt(Event) on Type ent , all(All)

GBFD119115

Power Control

0(0.0), 1(0.1), 2(0.2), 3(0.3), 4(0.4), Enumerati 5(0.5), on Type 6(0.6), 7(0.7), 8(0.8), 9(0.9), 10(1.0)

Antenna Altitude ALTIDECI Decimal Part

Decimal part of the GBFDantenna 115402 altitude

BSSBased Interval LCS (Cell Type ID + TA)

0~9

GPS ALTITUD antenna E altitude

Height of the ADD specified MRFDBSC6900 GPS(Man GSP 210502 datory) receiver antenna

BSC/RNC Interval Clock Type

1000~100 00

Antenna ALTITUD Altitude E Int Part

SET GCELLLC BSC6900 S(Optiona l)

Integer part of the GBFDantenna 115402 altitude

BSSBased Interval LCS (Cell Type ID + TA)

0~6553

GPS ALTITUD antenna EIMP altitude

Height of the ADD specified MRFDBSC6900 GPS(Man GSP 210502 datory) receiver antenna Alarm severity. One or more severities EXP can be MRFDBSC6900 ALMLOG( selected. 210304 Optional) By default, all severities are selected. SET ALMLVL( Mandator y) SET ALMSCR BSC6900 N(Mandat ory) SET ENVALM PARA(Op tional) Alarm severity. One or more severities can be MRFDselected. 210304 By default, all severities are selected.

BSC/RNC Interval Clock Type

3281~328 10

ALVL

Alarm Severity

Faulty Bit Field Managem Type ent

Critical, Major, Minor, Warning

ALVL

Alarm Severity

Critical(Cr itical), Major(Maj Faulty Enumerati or), Managem on Type Minor(Min ent or), Warning( Warning)

AMPC0

Whether Feed Tri. SET to supply 0 TMA BTSDAT power to BSC6900 Configura UBP(Opti the TMA tion onal) on tributary 0 Whether Feed Tri. SET to supply 1 TMA BTSDAT power to BSC6900 Configura UBP(Opti the TMA tion onal) on tributary 1

GBFD111202 MRFD210601

O&M of DISABLE BTS D(Disable Connectio Enumerati d), n with on Type ENABLE TMA D(Enable (Tower d) Mounted Amplifier) O&M of DISABLE BTS D(Disable Connectio Enumerati d), n with on Type ENABLE TMA D(Enable (Tower d) Mounted Amplifier)

AMPC1

GBFD111202 MRFD210601

AMPC2

Whether Feed Tri. SET to supply 2 TMA BTSDAT power to BSC6900 Configura UBP(Opti the TMA tion onal) on tributary 2 Whether Feed Tri. SET to supply 3 TMA BTSDAT power to BSC6900 Configura UBP(Opti the TMA tion onal) on tributary 3 Whether Feed Tri. SET to supply 4 TMA BTSDAT power to BSC6900 Configura UBP(Opti the TMA tion onal) on tributary 4 Whether Feed Tri. SET to supply 5 TMA BTSDAT power to BSC6900 Configura UBP(Opti the TMA tion onal) on tributary 5

GBFD111202 MRFD210601

O&M of DISABLE BTS D(Disable Connectio Enumerati d), n with on Type ENABLE TMA D(Enable (Tower d) Mounted Amplifier) O&M of DISABLE BTS D(Disable Connectio Enumerati d), n with on Type ENABLE TMA D(Enable (Tower d) Mounted Amplifier) O&M of DISABLE BTS D(Disable Connectio Enumerati d), n with on Type ENABLE TMA D(Enable (Tower d) Mounted Amplifier) O&M of DISABLE BTS D(Disable Connectio Enumerati d), n with on Type ENABLE TMA D(Enable (Tower d) Mounted Amplifier)

AMPC3

GBFD111202 MRFD210601

AMPC4

GBFD111202 MRFD210601

AMPC5

GBFD111202 MRFD210601

Maximum degree by which the SET BSC can AMRBTS AMR BTS GCELLP control GBFDPWRNU BSC6900 PC Class WR2(Opti the power 115503 M onal) of the AMR BTS dynamical ly

AMR Power Control

Interval Type

1~16

Whether to enable the III power control Allow III SET algorithm AMRCAL Power GCELLP for AMR GBFDLPCALLO BSC6900 Control WR3(Opti calls. If 117601 WED For AMR onal) enabled, power control is performe d on AMR calls. Whether to enable the adaptive adjustme nt function of AMR downlink threshold. After this function is enabled, the BTS estimates AMR SET the longDownlink AMRDAD GCELLC term GBFDAdaptive BSC6900 THAW CAMR(O voice 115506 Threshold ptional) quality Allowed (indicated by the long-term FER(fram e erase ratio)) and compares the estimated result with the specified target voice quality. If

HUAWEI OFF(Not III Power Enumerati Allowed), Control on Type ON(Allow Algorithm ed)

AMR Coding Rate Enumerati NO(No), Threshold on Type YES(Yes) Adaptive Adjustme nt

Number of measure ment reports sampled for averaging downlink AMR signal strength. A single measure ment AMR SET report Filter AMRDLL GCELLP may not GBFDLength for BSC6900 EVFTLEN WR2(Opti reflect the 115503 DL onal) actual RX_LEV network situations accurately . Therefore , the BSC needs to average the measured values in several successiv e measure

AMR Power Control

Interval Type

1~20

Number of downlink AMR measure ment reports that the BSC predicts. The BSC takes a while to confirm the power AMR DL SET control AMRDLP MR. GCELLP effect of a GBFDREDLEN BSC6900 Number WR2(Opti power 115503 D Predicted onal) control command . Thus, the BSC makes a power control decision based on a measure ment report that lags behind the

AMR Power Control

Interval Type

0~3

Quality level threshold for decreasin g downlink AMR signal power. If the BTS transmits AMR signals at a quality AMR DL SET level less AMRDLQ Qual. GCELLP than GBFDBSC6900 HTHRED Upper WR2(Opti "AMR DL 115503 Threshold onal) Qual. Upper Threshold ", the BSC decrease s the power of the BTS. If (downlink receive level "AMR MAX Down Adj.

AMR Power Control

Interval Type

0~7

Quality level threshold for increasing downlink AMR signal power. If the BTS transmits AMR signals at a quality level AMR DL SET greater AMRDLQ Qual. GCELLP than GBFDBSC6900 LTHRED Lower WR2(Opti "AMR DL 115503 Threshold onal) Qual. Lower Threshold ", the BSC increases the power of the BTS. If (downlink receive level + "AMR MAX Up Adj. PC Value by

AMR Power Control

Interval Type

0~7

Number of measure ment reports sampled for averaging downlink AMR signal quality. A single measure ment AMR SET report AMRDLQ Filter GCELLP may not GBFDBSC6900 UAFTLEN Length for WR2(Opti reflect the 115503 DL Qual. onal) actual network situations accurately . Therefore , the BSC needs to average the measured values in several successiv e measure

AMR Power Control

Interval Type

1~20

During downlink power control, if the downlink receive quality level is equal to or greater than this threshold, "AMR DL AMR DL SET AMRDLQ RX_LEV Qual Bad GCELLP GBFDUALBAD BSC6900 Upper Trig WR2(Opti 115503 TRIG Threshold Threshold onal) " is increased by "AMR DL Qual Bad UpLEVDif f" to further increase the expected downlink power level.

AMR Power Control

Interval Type

0~7

During downlink power control, if the downlink receive quality level is equal to or greater than "AMR DL Qual Bad Trig AMR DL SET Threshold AMRDLQ Qual Bad GCELLP ", "AMR GBFDUALBAD BSC6900 UpLEVDif WR2(Opti DL 115503 UPLEV f onal) RX_LEV Upper Threshold " is increased by "AMR DL Qual Bad UpLEVDif f" to further increase the expected downlink power

AMR Power Control

Interval Type

0~63

Upper threshold for downlink AMR signal strength. If the downlink received AMR signal level is greater than this AMR DL SET threshold, AMRDLS RX_LEV GCELLP a power GBFDSHTHRE BSC6900 Upper WR2(Opti decrease 115503 D Threshold onal) is computed . Then, the power is decrease d by the least of the power decrease, maximum power adjustme nt step allowed by the

AMR Power Control

Interval Type

0~63

Lower threshold for downlink AMR signal strength. If the downlink received AMR signal level is less than this AMR DL SET threshold, AMRDLS RX_LEV GCELLP a power GBFDSLTHRE BSC6900 Lower WR2(Opti increase 115503 D Threshold onal) is computed . Then, the power is increased by the least of the power increase, "AMR MAX Up Adj. PC Value by RX_LEV", and "AMR

AMR Power Control

Interval Type

0~63

Whether to enable the algorithm for the AMRFUL SET AMR F-H loadLTOHALF GCELLH GBFDHo BSC6900 based HOALLO OBASIC( 510501 Allowed AMR W Optional) handover between full rate and half rate

HUAWEI Enumerati NO(No), II on Type YES(Yes) Handover

AMRFUL LTOHALF HOATCB ADJSTEP

With "F-H Ho Period" and the duration for triggering handover from full rate to half rate, this parameter determine s the AMR F-H SET current Ho ATCB GCELLH ATCB GBFDBSC6900 Adjust OBASIC( offset by 510501 Step Optional) which to choose the MSs to undergo handover from full rate to half rate. ATCB offset = (duration for triggering handover from full

HUAWEI Interval II Type Handover

0~255

ATCB threshold for the AMR handover from full rate to half rate. If the ATCB of AMRFUL SET AMR F-H an AMR LTOHALF GCELLH GBFDHo ATCB BSC6900 full rate HOATCB OBASIC( 510501 Threshold call is THRESH Optional) equal to or greater than this threshold, the AMR call is handed over from full rate to half rate.

HUAWEI Interval II Type Handover

0~255

AMRFUL LTOHALF HOPATH ADJSTEP

With "F-H Ho Period" and the duration for triggering handover from full rate to half rate, this parameter determine s the AMR F-H SET current Ho GCELLH path loss GBFDPathloss BSC6900 OBASIC( offset by 510501 Adjust Optional) which to Step choose the MSs to undergo handover from full rate to half rate. Path loss offset = (duration for triggering handover from full

HUAWEI Interval II Type Handover

0~255

AMRFUL LTOHALF HOPATH THRESH

Path loss threshold for the AMR handover from full rate to half rate. If the path AMR F-H SET loss of an Ho GCELLH AMR full GBFDBSC6900 Pathloss OBASIC( rate call is 510501 Threshold Optional) equal to or less than this threshold, the AMR call is handed over from full rate to half rate.

HUAWEI Interval II Type Handover

0~255

Quality threshold for the AMR handover from full rate to half rate. If the uplink and downlink receive AMRFUL SET AMR F-H quality LTOHALF GCELLH GBFDHo Qual. BSC6900 levels of HOQUAL OBASIC( 510501 Threshold an AMR THRESH Optional) full rate call are equal to or less than this threshold, the AMR call is handed over from full rate to half rate.

HUAWEI Interval II Type Handover

0~7

Load threshold for the AMR handover from full rate to half rate. AMRFUL SET AMR F-H If the cell LTOHALF GCELLH GBFDTraffic BSC6900 load is HOTHRE OBASIC( 510501 Threshold greater SH Optional) than this threshold, the AMR full rate calls are handed over to half rate.

HUAWEI Interval II Type Handover

0~100

ATCB threshold for the AMR handover from half rate to full rate. If the ATCB of AMRHAL SET AMR H-F an AMR FTOFULL GCELLH GBFDHo ATCB BSC6900 half rate HOATCB OBASIC( 510501 Threshold call is less THRESH Optional) than this threshold, the AMR call is handed over from half rate to full rate.

HUAWEI Interval II Type Handover

0~255

AMRHAL FTOFULL HOPATH THRESH

Path loss threshold for the AMR handover from half rate to full rate. If the path loss AMR H-F SET of an Ho GCELLH AMR half GBFDBSC6900 Pathloss OBASIC( rate call is 510501 Threshold Optional) greater than this threshold, the AMR call is handed over from half rate to full rate.

HUAWEI Interval II Type Handover

0~255

Whether to enable the algorithm for the uplink and AMRHAL Allow SET downlink FTOFULL AMR H-F GCELLH GBFDBSC6900 receive HOQUAL QualityOBASIC( 510501 quality ALLOW based HO Optional) based AMR handover from half rate to full rate

HUAWEI Enumerati NO(No), II on Type YES(Yes) Handover

Quality threshold for the AMR handover from half rate to full rate. If the receive quality AMRHAL SET AMR H-F level of an FTOFULL GCELLH GBFDHo Qual. BSC6900 AMR half HOQUAL OBASIC( 510501 Threshold rate call is THRESH Optional) greater than this threshold, the AMR call is handed over from half rate to full rate.

HUAWEI Interval II Type Handover

0~7

Load threshold for the AMR handover from half rate to full AMRHAL SET rate. If the AMR H-F FTOFULL GCELLH cell load GBFDTraffic BSC6900 HOTHRE OBASIC( is less 510501 Threshold SH Optional) than this threshold, the AMR half rate calls are handed over to full rate.

HUAWEI Interval II Type Handover

0~100

AMR AMRMAX MAX Up ADJPCV Adj. PC AL Value by Qual.

Maximum step by which the power SET can be GCELLP GBFDBSC6900 increased WR2(Opti 115503 according onal) to received signal quality

AMR Power Control

Interval Type

0~32

Maximum step by which the power can be decrease d when the received signal quality belongs to quality zone 0. AMR Huawei MAX SET power AMRMAX Down Adj. GCELLP control GBFDBSC6900 STEP0 Value WR2(Opti algorithm 115503 Qual. onal) generatio Zone 0 n II classifies the received signal quality into three quality zones. The maximum step by which the power can be

AMR Power Control

Interval Type

0~30

Maximum step by which the power can be decrease d when the received signal quality belongs to quality zone 1. AMR Huawei MAX SET power AMRMAX Down Adj. GCELLP control GBFDBSC6900 STEP1 Value WR2(Opti algorithm 115503 Qual. onal) generatio Zone 1 n II classifies the received signal quality into three quality zones. The maximum step by which the power can be

AMR Power Control

Interval Type

0~30

Maximum step by which the power can be decrease d when the received signal quality belongs to quality zone 2. AMR Huawei MAX SET power AMRMAX Down Adj. GCELLP control GBFDBSC6900 STEP2 Value WR2(Opti algorithm 115503 Qual. onal) generatio Zone 2 n II classifies the received signal quality into three quality zones. The maximum step by which the power can be

AMR Power Control

Interval Type

0~30

AMR AMRMAX MAX Up VALADJR Adj. PC X Value by RX_LEV

Maximum step by which the power SET can be GCELLP GBFDBSC6900 increased WR2(Opti 115503 according onal) to received signal level

AMR Power Control

Interval Type

0~32

Whether to enable the compens ation of AMR measure ment reports in Huawei power control algorithm generatio n II AMR MR. SET If this AMRMRC Compens GCELLP parameter GBFDBSC6900 OMPREG ation WR2(Opti is set to 115503 Allowed onal) YES, Huawei power control algorithm generatio n II puts a currently received measure ment report into the measure ment report

AMR Power Control

Enumerati NO(No), on Type YES(Yes)

AMRPCA AMR PC DJPERIO Interval D

Minimum interval between SET two GCELLP consecuti GBFDBSC6900 WR2(Opti ve AMR 115503 onal) power control command s

AMR Power Control

Interval Type

1~15

Maximum step by which the power AMR SET can be MAX AMRQUA GCELLP decrease GBFDDown Adj. BSC6900 LSTEP WR2(Opti d 115503 PC Value onal) according by Qual. to received signal quality

AMR Power Control

Interval Type

0~4

Number of levels by which the BTS increases the power of an SACCH frame. This parameter is used AMR SET for AMRSAD SACCH GCELLP SACCH GBFDLUPGRA Downlink BSC6900 WRBASI power 110703 DE Power C(Optiona control. Upgrade l) When sending an SACCH frame, the BTS increases the power of the SACCH frame by this specified

Enhanced Power Interval Control Type Algorithm

0~15

AMR AMRTCH TCH/H HPRIORA Prior LLOW Allowed

Whether to enable the BSC to assign AMR half rate channels preferenti ally SET according GCELLC to the GBFDBSC6900 HMGAD( channel 115502 Optional) types allowed by the MSC and the current TCH seizure ratio of the cell

AMR HR

Enumerati OFF(Off), on Type ON(On)

Load threshold for assigning half rate channels preferenti ally. If the current AMR TCH SET AMRTCH TCH/H seizure GCELLC GBFDHPRIORL Prior Cell BSC6900 ratio of HMGAD( 115502 OAD Load the cell is Optional) Threshold greater than this threshold, AMR half rate channels are assigned preferenti ally.

AMR HR

Interval Type

0~99

Whether to enable the adaptive adjustme nt function of AMR uplink threshold. After this function is enabled, the BTS estimates AMR SET the longUplink AMRUAD GCELLC term GBFDAdaptive BSC6900 THAW CAMR(O voice 115506 Threshold ptional) quality Allowed (indicated by the long-term FER(fram e erase rate)) and compares the estimated result with the specified target voice quality. If

AMR Coding Rate Enumerati NO(No), Threshold on Type YES(Yes) Adaptive Adjustme nt

Number of measure ment reports sampled for averaging uplink AMR signal strength. A single measure ment AMR SET report Filter AMRULL GCELLP may not GBFDLength for BSC6900 EVFTLEN WR2(Opti reflect the 115503 UL onal) actual RX_LEV network situations accurately . Therefore , the BSC needs to average the measured values in several successiv e measure

AMR Power Control

Interval Type

1~20

Number of uplink AMR measure ment reports that the BSC predicts. The BSC takes a while to confirm the power control AMR UL SET effect of a AMRULP MR. GCELLP power GBFDREDLEN BSC6900 Number WR2(Opti control 115503 D Predicted onal) command . Thus, the BSC makes a power control decision based on a measure ment report that lags behind the changes

AMR Power Control

Interval Type

0~3

Quality level threshold for decreasin g the power of an uplink AMR call. If the MS transmits AMR signals at a quality level less AMR UL SET than AMRULQ Qual. GCELLP "AMR GBFDBSC6900 HTHRED Upper WR2(Opti ULQual. 115503 Threshold onal) Upper Threshold ", the BTS decrease s the power of the MS. If (uplink receive level "AMR MAX Down Adj. PC Value by Qual.") < "AMR

AMR Power Control

Interval Type

0~7

Quality level threshold for increasing the power of an uplink AMR call. If the MS transmits AMR signals at a quality level AMR UL SET greater AMRULQ Qual. GCELLP than GBFDLOWTHR BSC6900 Lower WR2(Opti "AMR UL 115503 ED Threshold onal) Qual. Lower Threshold ", the BTS increases the power of the MS. If (uplink receive level + "AMR MAX Up Adj. PC Value by Qual.") > "AMR UL

AMR Power Control

Interval Type

0~7

Number of measure ment reports sampled for averaging uplink AMR signal quality. A single measure ment AMR SET report AMRULQ Filter GCELLP may not GBFDBSC6900 UAFTLEN Length for WR2(Opti reflect the 115503 UL Qual onal) actual network situations accurately . Therefore , the BSC needs to average the measured values in several successiv e measure

AMR Power Control

Interval Type

1~20

During uplink power control, if the uplink receive quality level is equal to or greater than this threshold, "AMR UL AMR UL SET RX_LEV AMRULQ Qual. Bad GCELLP Upper GBFDUALBAD BSC6900 Trig WR2(Opti Threshold 115503 TRIG Threshold onal) " is increased by "AMR UL Qual. Bad UpLEVDif f" to further increase the expected uplink power level.

AMR Power Control

Interval Type

0~7

During uplink power control, if the uplink receive quality level is equal to or greater than "AMR UL Qual. Bad Trig Threshold AMR UL SET AMRULQ ", "AMR Qual. Bad GCELLP GBFDUALBAD BSC6900 UL UpLEVDif WR2(Opti 115503 UPLEV RX_LEV f onal) Upper Threshold " is increased by "AMR UL Qual. Bad UpLEVDif f" to further increase the expected uplink power

AMR Power Control

Interval Type

0~63

Upper threshold for uplink AMR signal strength If the uplink received AMR signal level is greater than this threshold, AMR UL SET a power AMRULS RX_LEV GCELLP decrease GBFDSHTHRE BSC6900 Upper WR2(Opti is 115503 D Threshold onal) computed . Then, the power is decrease d by the least of the power decrease, maximum power adjustme nt step allowed by the quality

AMR Power Control

Interval Type

0~63

Lower threshold for uplink AMR signal strength. If the uplink received AMR signal level is less than this threshold, AMR UL SET a power AMRULS RX_LEV GCELLP increase GBFDSLTHRE BSC6900 Lower WR2(Opti is 115503 D Threshold onal) computed . Then, the power is increased by the least of the power increase, "AMR MAX Up Adj. PC Value by RX_LEV", and "AMR MAX Up

AMR Power Control

Interval Type

0~63

AN19

Maximum number of retransmi ssions of the Ainterface circuit reset message. When an Ainterface circuit of the BSC MAX is reset, Retrans SET the BSC Reset OTHSOF sends the GBFDBSC6900 Circle TPARA(O reset 111803 Msg on Aptional) message I to the MSC and starts a timer. If the BSC fails to receive the Ainterface circuit reset response message from the MSC

A Interface Interval Circuit Type Managem ent

0~65535

AN4

Maximum number of times of resending a reset message at the A interface. When the BSC6900 is reset, the BSC6900 sends a MAX reset Reset SET message Mesg AITFOTH to the GBFDBSC6900 Retransmi PARA(Op MSC and 111803 ssion on tional) starts a A-I timer. If the timer expires when the BSC6900 waits for a response message, the BSC6900 resends the reset message and restarts a Maximum

A Interface Interval Circuit Type Managem ent

0~65535

gain to the signals from the remote end. If the parameter SET is set to a ANC_Max ANC Max GBFDBSC6900 TCPARA( small _Gain Gain 115703 Optional) value, the target SNR may be restrained when the signal arrives at the local

Automatic Noise Interval Compens Type ation (ANC)

3~30

ANC_Swit ANC ch Switch

Whether to enable the SET adaptive GBFDBSC6900 TCPARA( noise 115703 Optional) cancel (ANC) function

Automatic CLOSE(C Noise Enumerati lose), Compens on Type OPEN(Op ation en) (ANC)

ANC ANC_Tar Target get_SNR SNR

SET BSC6900 TCPARA( Optional)

ANGLE

SET RET BTSANT Antenna BSC6900 ANGLE(M Tilt Angle andatory)

ANI

Adjacent Node ID

ANI

Adjacent node ID

ADD ADJNOD E(Mandat ory) ADD BSC6900 IPPATH( Mandator y) ADD ADJMAP( Mandator ADD IPMUX(M andatory) BSC6900 ADD IPPATHBI ND(Mand atory)

The system adjusts the remote input so that the ratio of the remote signal to the local noise is above the value of this Tilt angle of the RET antenna, it is accurate to one place of decimal, for example, the tilt can be 7.7

GBFD115703

Automatic Noise Interval Compens Type ation (ANC)

10~30

MRFD210602

Remote String Electrical Type Tilt

None

GBFD118601 GBFDUniquely 118602 identifies GBFDan 118605 adjacent GBFDnode 118611 GBFD118622 Adjacent node identifier of this IP path

Abis over IP A over IP IP QOS Interval Abis IP Type over E1/T1 A IP over E1/T1

0~4599

None

None

Interval Type

0~4599

ANM

Alarm Name

SET New ENVALM MRFDBSC6900 name of PARA(Op 210304 the alarm tional)

Faulty String Managem Type ent

None

ANR_Mo ANR de Mode

SET ANR BSC6900 TCPARA( mode Optional)

GBFD115603

MODE0( Automatic Mode 0), Noise Enumerati MODE1( Restraint on Type Mode 1), (ANR) MODE2( Mode 2)

This parameter determine s the noise depressio n degree. ANR ANR_Noi SET A large Noise GBFDse_Reduc BSC6900 TCPARA( absolute Reduction 115603 tion_Level Optional) value of Level this parameter correspon ds to a strong depressio n.

Automatic Noise Interval Restraint Type (ANR)

-32~0

ANR ANR_Noi Noise se_Target Target _Level Level

ANR SET target BSC6900 TCPARA( noise Optional) level

GBFD115603

Automatic Noise Interval Restraint Type (ANR)

-64~0

ANR_Swit ANR ch Switch

Whether to enable the SET adaptive GBFDBSC6900 TCPARA( noise 115603 Optional) restrain (ANR) function

Automatic CLOSE(C Noise Enumerati lose), Restraint on Type OPEN(Op (ANR) en)

Antenna ANTAAN Azimuth GLE Angle

Size of SET the GCELLLC azimuth BSC6900 S(Optiona angle of l) the cell antenna Length of the feeder cable. The GPS satellite card is connecte d to the antenna through feeder cables. The transmissi on delay on the feeder cable can be calculated on the basis of the length of the feeder cable, thus increasing the timing accuracy of the satellite card. Power supply switch of the GPS antenna feeder

GBFD115402 GBFD118201

BSSBased LCS (Cell ID + TA) Interval Type SoftSynchroni zed Network

0~360

GPS ANTENN Antenna ALONG Delay

SET BTSDGP SBP(Opti onal) BSC6900 SET BTSUSC UBP(Opti onal)

GBFD510401 MRFD210501

BTS GPS Synchroni Interval zation Type BTS/Nod eB Clock

0~1000

Antenna ANTENN Power APOWER Supply SWITCH Switch

SET BTSDGP SBP(Opti onal) BSC6900 SET BTSUSC UBP(Opti onal)

GBFD510401 MRFD210501

SENDPO BTS GPS WER(Sen Synchroni Enumerati d Power), zation on Type NOPOW BTS/Nod ER(No eB Clock Power)

GBFDE1T1 antiADD E1T1 antiANTIERR 118611 error BSC6900 MPGRP( error FLAG GBFDswitch Optional) switch. 118622

Abis IP over Enumerati OFF(OFF E1/T1 on Type ), ON(ON) A IP over E1/T1

Burglar Alarm AntiTheft Auto Allow Clear Permit

ANTNO

Antenna No.

ANTPAS Antenna SNO Pass No

Whether to enable the BTS SET to clear BTSTHEF GBFDBSC6900 the TALM(Op 111202 burglar tional) alarm automatic ally LOD RETANT CFG(Man datory) SET Number BTSANT MRFDBSC6900 of the ANGLE(M 210602 antenna andatory) SET RETANT ENB(Man datory) Number of the ADD antenna TRXBIND GBFDfeeder BSC6900 2PHYBR channel 111202 D(Mandat mapped ory) to the RXU Antenna

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

Remote Interval Electrical Type Tilt

0~35

O&M of BTS

Enumerati A(A), B(B) on Type

pass No. of the RXU of a sublocation Subgroup. ADD Location The ANTPAS BTSBIND GBFDGroup BSC6900 parameter SNO LOCGRP( 510104 Antenna is Optional) Pass No. configure d only when the MRRU or GRRU is used in the subADD BTSANTF EEDERB Antenna RD(Mand pass Down atory) number of GBFDAORB TRX1 A BSC6900 SET the 111202 or B BTSANTF downlink EEDERC tributary ONNECT( Optional)

Multi-site Enumerati A(A), B(B) Cell on Type

O&M of BTS

A(A), Enumerati B(B), on Type NULL(NU LL)

APN

APP

Number ADD of a port MTP3LN BSC6900 on the A K(Mandat interface ory) board Upper layer applicatio n type of the SCTP link. The upper layer applicatio n type of A and LB interface is M3UA. ADD In the Applicatio SCTPLN BSC6900 BSC n type K(Mandat disaster ory) tolerance, the applicatio n type is BBAP in the case of the communi cation between the primary and A interface port No.

GBFD111804

A Interface Protocol Process

Interval Type

0~335

GBFD118602

M3UA(M3 Enumerati UA), A over IP on Type BBAP(BB AP)

Applicatio ADD n type of Applicatio SEMILIN GBFDAPPTYPE BSC6900 the semin Type K(Mandat 114701 permanen ory) t link Update frequency of the value N (packet drop interval), SET indicating BSCPSS GBFDthat the BSC6900 OFTPAR 119904 packet A(Optiona drop l) interval is updated after N packets are transmitte d.

MTP2(MT SemiP2), Permane Enumerati OTHER( nt on Type OTHER), Connectio TCSTM1( n TCSTM1)

AqmM

AQM N Update Interval

PS Active Package Interval Managem Type ent

1~65535

SET AQM BSCPSS AqmMaxT Maximum BSC6900 OFTPAR h Threshold A(Optiona l)

SET AQM BSCPSS AqmMinT Congestio BSC6900 OFTPAR h n A(Optiona Threshold l)

Upper length threshold of the TBF buffer queue. If the length of the TBF buffer queue exceeds this threshold, whether the packets are discarded is determine d according to the packet Congestio n threshold of the TBF buffer queue. If the congestio n level in the TBF buffer queue exceeds this threshold, whether the packets are discarded actively is determine d according to the

GBFD119904

PS Active Package Interval Managem Type ent

1~65535

GBFD119904

PS Active Package Interval Managem Type ent

1~65535

AQM Packet AqmNinit Discard Initial Interval

Initial value of the interval (indicated by N) at which the packets in the TBF buffer queue are discarded . The value N indicates SET the BSCPSS frequency GBFDBSC6900 OFTPAR 119904 of A(Optiona discarding l) the packets in the TBF buffer queue. The greater the value N, the lower the frequency of discarding packets, and the Lower

PS Active Package Interval Managem Type ent

1~65535

threshold of the interval for discarding AQM SET the Packet BSCPSS packets in AqmNLo Discard GBFDBSC6900 OFTPAR the TBF werBound Interval 119904 A(Optiona buffer Lower l) queue, Threshold that is, the minimum value of N (packet drop

PS Active Package Interval Managem Type ent

1~65535

Upper threshold of the interval for discarding AQM SET the Packet BSCPSS packets in AqmNUp Discard GBFDBSC6900 OFTPAR the TBF Bound Interval 119904 A(Optiona buffer Upper l) queue, Threshold that is, the maximum value of N (packet drop SET BSCPSS AQM BSC6900 OFTPAR switch A(Optiona l)

PS Active Package Interval Managem Type ent

1~65535

AqmSwitc AQM h Switch

GBFD119904

PS Active CLOSE(C Package Enumerati lose), Managem on Type OPEN(Op ent en)

SET AQM BSCPSS AqmTarT Target BSC6900 OFTPAR h Threshold A(Optiona l)

Target threshold of the GBFDTBF 119904 buffer queue Local area code, for MRFDexample, 210301 021 for Shanghai

PS Active Package Interval Managem Type ent

1~65535

Area AreaCode Code

SET BSCBASI BSC6900 C(Optiona l)

Configura tion Interval Managem Type ent

0~65535

CMP BRDARE A(Optiona AREAFLA MRFDArea flag BSC6900 l) Area flag G 210401 LOD PATCH(O ptional)

PRIMARY (Primary Area), BSC/RNC STANDB Software Enumerati Y(Standb Managem on Type y Area), ent ALL(Prim ary and Standby Area) PRIMARY BSC/RNC (Primary), Software Enumerati STANDB Managem on Type Y(Standb ent y)

LOD BRD(Opti onal) AREAFLA MRFDArea flag BSC6900 SYN Area flag G 210401 BRDARE A(Optiona l)

Threshold for reporting the recovery alarm for the abnormal release alarm. If the percentag e of the abnormal channel SET releases Abnormal AREDIST GTRXRL is equal to GBFDRelease BSC6900 HD ALM(Opti or less 111004 Threshold onal) than this threshold, the recovery alarm for the abnormal release alarm is reported. That is, the abnormal release alarm is cleared.

Radio Dedicated Interval Channel Type Managem ent

0~80

ARELBA SE

Release statistics base for subchann els. This parameter indicates the number of times that a subchann el is activated. In a Abnormal SET timeslot, Release GTRXRL the GBFDBSC6900 Statistic ALM(Opti release 111004 Base onal) statistics base, B, multiplied by the number of channels, N, is the channel release sum, S. If the percentag e of the abnormal channel releases

Radio Dedicated Interval Channel Type Managem ent

5~126

Threshold for reporting the abnormal release alarm. In a timeslot, the release statistics base, B, multiplied by the number of SET channels, Abnormal ARELWT GTRXRL N, is the GBFDWarn BSC6900 HD ALM(Opti channel 111004 Threshold onal) release sum, S. If the percentag e of the abnormal channel releases in the latest S channel releases exceeds this threshold, the

Radio Dedicated Interval Channel Type Managem ent

5~100

ARP ARPRET packet RY resend times

Retransmi ssion times upon ARP timeout. When the ARP request times exceeds the retransmi STR ssion time GBFDBSC6900 IPCHK(O without a 118609 ptional) response, the ARP/BFD detection failure alarm is reported. This may trigger the port or board switchove r.

IP Fault Detection Interval Based on Type BFD

3~10

ARP packet STR ARPTIME timeBSC6900 IPCHK(O OUT out[100m ptional) s]

ARP packet timeout time

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

3~10

ASN

A interface slot No.

ADD MTP3LN BSC6900 K(Mandat ory) ADD ATERSL( Optional) BSC6900 ADD ATERCO NSL(Opti onal) ADD MTP3LN BSC6900 K(Mandat ory)

ASN

A interface slot No.

ASRN

A interface subrack No.

Number of the slot where the A interface board is located Number of the slot where the A interface board is located Number of the subrack where the A interface board is located

GBFD111804

A Interface Protocol Process

Interval Type

0~27

GBFD111804

A Interface Protocol Process

Interval Type

0~27

GBFD111804

A Interface Protocol Process

Interval Type

0~11

ASS

Event Type

EXP ALMLOG( Optional) BSC6900 STA ALMLOG( Optional)

Network managem ent type of the alarm. By MRFDdefault, all 210304 network managem ent types are selected.

Faulty Bit Field Managem Type ent

power, env, sig, trunk, hardware, software, run, comm, service, handle

ASS

Event Type

Network managem ent type of the SET alarm. By ENVALM MRFDBSC6900 default, all PARA(Op 210304 network tional) managem ent types are selected.

power(Po wer System), env(Envir onment System), sig(Signal ing System), trunk(Tru nk System), hardware( Faulty Hardware Enumerati Managem System), on Type ent software( Software System), run(Runni ng System), comm(Co mmunicati on System), service(Q oS), handle(Pr ocessing

Switch for assigning the Assigning SET channel AssignBet Better GCELLH GBFDBSC6900 of a better terCellEn Cell OAD(Opti 110502 cell to the Allowed onal) MS during MS access.

Assignme nt and Immediat Enumerati OFF(Off), e on Type ON(On) Assignme nt

When this parameter is set to ENABLE, if the cell supports direct retry and the current cell load is equal to or larger than the value of Assignme SET "Cell ASSLOA nt Cell GCELLC direct GBFDDJUDGE Load BSC6900 CBASIC( retry 110607 EN Judge Optional) forbidden Enable threshold" in "SET GCELLO THEXT" during the assignme nt, the BSC6900 continues with the direct retry procedure . When this

Direct Retry

DISABLE( Enumerati Disable), on Type ENABLE( Enable)

Offset relative to the level threshold for Assign to SET ASSOLR determini Overlayer GCELLC GBFDXLEVOFF BSC6900 ng RxLev HMGAD( 113201 SET whether Offset Optional) to assign a channel in the overlaid subcell

Concentri Interval c Cell Type

0~61

SET BTSAPM UBP(Opti onal) SET Associate ASSORX BTSDEM d RXU BSC6900 UCN UBP(Opti Board CN onal) SET BTSDHE UBP(Opti onal)

Number of the cabinet where the associate d RXU board is installed. This parameter is valid for DRRU, MRRU, GRRU, or BTS3900 E board in GBFDthe 111202 remote monitorin g subrack of the DBS3036, DBS3900 GSM, or BTS3900 E GSM. The associate d RXU board cannot be associate d with other

O&M of BTS

Interval Type

0~62,255

Number of the cabinet where the associate d RXU board is installed. This parameter is valid for DRRU, MRRU, GRRU, or BTS3900 SET E board in Associate ASSORX BTSRXU the GBFDd RXU BSC6900 UCN BP(Mand remote 111202 Board CN atory) monitorin g subrack of the DBS3036, DBS3900 GSM, or BTS3900 E GSM. The associate d RXU board cannot be associate d with other SET BTSAPM UBP(Opti Number onal) of the slot SET Associate where the ASSORX BTSDEM GBFDd RXU BSC6900 associate USN UBP(Opti 111202 Board SN d RXU onal) board is SET installed. BTSDHE UBP(Opti onal) Number of the slot SET Associate where the ASSORX BTSRXU GBFDd RXU BSC6900 associate USN BP(Mand 111202 Board SN d RXU atory) board is installed.

O&M of BTS

Interval Type

0~62

O&M of BTS

Interval Type

0~23,255

O&M of BTS

Interval Type

0~23

SET BTSAPM UBP(Opti onal) Associate SET ASSORX d RXU BTSDEM BSC6900 USRN Board UBP(Opti SRN onal) SET BTSDHE UBP(Opti onal)

Number of the subrack where the GBFDassociate 111202 d RXU board is installed.

O&M of BTS

Interval Type

0~255

Associate SET ASSORX d RXU BTSRXU BSC6900 USRN Board BP(Mand SRN atory)

Absolute SET Signal OTHSOF ASSThres BSC6900 Strength TPARA(O Threshold ptional)

Number of the subrack where the associate d RXU board is installed. Absolute level threshold for automatic optimizati on of neighbor cells and frequenci es. The measure ment results in measure ment reports are screened and counted according to this threshold. If the signal strength of a neighbor cell in a measure ment report is greater

GBFD111202

O&M of BTS

Interval Type

0~254

GBFD510901

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

0~63

ASSTIME T3107 R

After the BSC6900 delivers an assignme nt command , the T3107 timer starts. If the BSC6900 SET receives GCELLT an GBFDBSC6900 MR(Optio assignme 110502 nal) nt complete message within the scheduled time, the T3107 timer stops. If the timer expires, the BSC6900 sends an

Assignme nt and Immediat Interval e Type Assignme nt

500~6000 0

AT1

T1

Timer for waiting for a single Ainterface circuit blocking or unblockin g answer. The BSC6900 starts this T1 timer after sending a single ASET interface GBFDBSC6900 BSCTMR( 111203 circuit Optional) blocking or unblockin g message. If the BSC6900 does not receive a blocking or unblockin g answer from the MSC before MSC reset protection timer, that is, interval between the time SET when the BSCAITF BSC6900 GBFDBSC6900 TMR(Opti receives 111803 onal) an MSC reset message and the time when the BSC6900 answer to

O&M of BSC

Interval Type

1~300

AT13

T13 -s

A Interface Interval Circuit Type Managem ent

1~300

AT17

T17 -s

T17 timer. When receiving an MSC overload message or a single point congestio n message for the first time, the SET BSC6900 BSCAITF increases GBFDBSC6900 TMR(Opti the level 111705 onal) of the A interface flow control and starts the T17 and T18 timers at the same time. Timers T17 and T18 are set for adjusting the flow

GSM Flow Control

Interval Type

1~300

AT18

T18 -s

T18 timer. When receiving an MSC overload message or a single point congestio n message for the first time, the SET BSC6900 BSCAITF increases GBFDBSC6900 TMR(Opti the level 111705 onal) of the A interface flow control and starts the T17 and T18 timers at the same time. Timers T17 and T18 are set for adjusting the flow

GSM Flow Control

Interval Type

1~300

AT19

T19

Timer for waiting for an Ainterface circuit reset answer. The BSC6900 starts this timer after sending an Ainterface circuit reset SET message. BSC6900 BSCTMR( When this Optional) timer expires for the first time, the BSC6900 resends the circuit reset message to the MSC. If this timer expires for the second

GBFD111203 GBFD111803

O&M of BSC A Interval Interface Type Circuit Managem ent

1~300

AT20

T20

SET BSC6900 BSCTMR( Optional)

AT4

T4 -s

SET BSCAITF BSC6900 TMR(Opti onal)

Timer for waiting for an Ainterface circuit group blocking or unblockin g answer. After sending a CIC group blocking/u nblocking message over the A interface, the BSC6900 starts the timer T20. If the BSC6900 fails to receive a response from the MSC before the first expiry of T20, the BSC6900 Timer for waiting for an Ainterface reset answer

GBFD111203

O&M of BSC

Interval Type

1~300

GBFD111803

A Interface Interval Circuit Type Managem ent

1~300

Whether to enable the ATCB handover algorithm for the concentric cell. According to the neighbor cell signal, the ATCB handover Concentri SET algorithm ATCBHO c Circles GCELLH determine GBFDBSC6900 EN ATCB HO OBASIC( s the 113201 Allowed Optional) coverage of the overlaid subcell and balances the load between the overlaid subcell, underlaid subcell, and neighbor cell.

NO(Close Concentri Enumerati ), c Cell on Type YES(Ope n)

Hysteresi s in the distance between the boundary of the overlaid subcell and the boundary of the underlaid subcell. Distance This SET Hysteresi parameter GCELLH ATCBHY s helps to GBFDBSC6900 OEDBPA ST Between 114402 adjust RA(Optio Boundarie "Distance nal) s Between Boudaries of Subcells" and thus to prevent ping-pong handover between the overlaid and underlaid subcells. Assume

Enhanced DualInterval Band Type Network

0~63

Distance between the boundary of the overlaid subcell and the boundary of the underlaid subcell. This parameter specifies Distance SET the Between GCELLH ATCBTH difference GBFDBoundarie BSC6900 OEDBPA RED between 114402 s of RA(Optio the Subcells nal) coverage of the overlaid subcell and the coverage of the underlaid subcell in the concentric cell or dualfrequency network Whether to enable the BSC to use a 8 SET Switch of kbit/s OTHSOF GBFDAter8KSw 8K on BSC6900 timeslot to TPARA(O 116901 Ater transmit 8 ptional) kbit/s data at the Ater interface

Enhanced DualInterval Band Type Network

0~63

Flex Ater

Enumerati NO(No), on Type YES(Yes)

Whether to enable the BSC to assign half rate SET HR channels AterCong OTHSOF GBFDAllocation BSC6900 preferenti HRFlag TPARA(O 116901 Flag ally when ptional) the Ater interface is congeste d

Close(Clo Enumerati se), Flex Ater on Type Open(Op en)

Threshold for considerin g the Ater interface, if congeste d, the BSC determine s whether to assign full or half rate channels Congestio SET preferenti AterCong n Ratio on OTHSOF ally GBFDBSC6900 stRatio Ater TPARA(O according 116901 Resource ptional) to the congestio n situations at the Ater interface. If the Ater resource usage exceeds this parameter , the Ater interface is

Flex Ater

Interval Type

80~100

ADD MTP3LN K(Mandat ory) ADD ATERE1T 1(Mandat ory) ADD Ater ATERCO connectio NPATH(O ATERIDX BSC6900 n path ptional) index ADD ATERSL( Mandator y) ADD ATERCO NSL(Man datory) ADD SEMILIN

Index of an Ater GBFDconnectio 111203 n path

O&M of BSC

Interval Type

0~254

Threshold for enabling the BSC local switching. Ater Jam When the AterJamT Rate for SET congestio GBFDhreshold2 BSC BSC6900 BSSLS(O n rate at 117701 StartLs Local ptional) the Ater Switch interface exceeds this threshold, the function is enabled.

BSC Local Switch

Interval Type

0~100

ADD MTP3LN K(Mandat ory) ADD ATERMA ATERSL( Ater Mask BSC6900 SK Mandator y) ADD ATERCO NSL(Man datory)

Ater interface timeslot mask

GBFD111203

O&M of BSC

Bit Field Type

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

Whether to configure the Ater OML link used for the TC subrack for the port. If it is actually configure d and you specify that it is ADD not Whether ATEROM SEMILIN configure GBFDor not for BSC6900 LFLAG K(Mandat d, the TC 114701 OML ory) subrack fails to start. If it is not configure d and you specify that it is already configure d, crosstalk occurs on the timeslot over the ADD ATEROM Ater OML ATEROM BSC6900 LINX Index L(Mandat ory) Ater maintena MRFDnce link 210301 index

SemiPermane Enumerati nt NO, YES on Type Connectio n

Configura tion Interval Managem Type ent

0~1

Ater connectio n path index,The Ater ADD index is ATERPID Connectio ATEROM MRFDBSC6900 set X n Path L(Mandat 210301 through Index ory) the ADD ATERCO NPATH command ADD ATERSL( Ater Indentifies Optional) ATERSLI Signaling an Ater GBFDBSC6900 ADD D Channel signaling 111203 ATERCO ID channel NSL(Opti onal)

Configura tion Interval Managem Type ent

0~254

O&M of BSC

Interval Type

0~2047

Ater ATERTR Interface ANSMOD Transfer E Mode

SET BSCBASI BSC6900 C(Mandat ory)

ATN

STR Antenna BTSVSW Tributary BSC6900 RTST(Opt No. ional)

Transport mode of the Ater interface. The Ater interface can be in TDM or in IP transport mode. Number of the RF port on the RF front-end board of the BTS. The number is unique in a board.

GBFD116902

Ater Compres Enumerati TDM(TD sion on Type M), IP(IP) Transmis sion

GBFD111202

O&M of BTS

A(Tributar y A), Enumerati B(Tributar on Type y B), ALL(All Tributary)

A ATSMAS interface K timeslot mask

ADD MTP3LN BSC6900 K(Mandat ory)

A interface timeslot mask

GBFD111804

A Interface Protocol Process

Bit Field Type

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

ATT

Attachdetach Allowed

Attachdetach Allowed (ATT). If this parameter is set to YES, when an MS is powered off, the SET network GCELLID GBFDBSC6900 does not LEBASIC( 110302 process Optional) any call connectio n for the MS as a called party. In this way, the network processin g time and GBFD111202 MRFD210601

IMSI Detach

Enumerati NO(No), on Type YES(Yes)

TMA SET Antenna attenuatio ATTENFA BTSRXU Tributary BSC6900 n factor of CTOR1 BP(Optio 1 Factor antenna nal) tributary 1

O&M of BTS Connectio Interval n with Type TMA (Tower Mounted Amplifier) O&M of BTS Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~15

TMA SET GBFDAntenna attenuatio ATTENFA BTSRXU 111202 Tributary BSC6900 n factor of CTOR2 BP(Optio MRFD2 Factor antenna nal) 210601 tributary 2

0~15

It SET specifies Loop AUSTOP BSC6900 E1T1LOP the None time[min] (Optional) loopback duration.

None

Interval Type

1~65535

It STR Test specifies AUSTOP BSC6900 E1T1TST time[min] the test (Optional) duration.

None

None

Interval Type

1~60

SET Authentic SSLAUT AUTHMO ation BSC6900 HMODE( DE Mode Mandator y)

SSL authentic ation MRFDmode of 210305 the peer certificate

NONE(Ve rify Security None), Enumerati Managem PEER(Ve on Type ent rify Peer Certificate )

AUTHMO Validate DE mode

ADD PPPLNK( BSC6900 Mandator y)

Validation mode of the PPP or MP link negotiatio n

GBFD118611 GBFD118622

Abis IP SERVER( over SERVER) Enumerati E1/T1 , on Type A IP over CLIENT( E1/T1 CLIENT)

AUTHMO Validate DE mode

ADD MPGRP( BSC6900 Mandator y)

Validation mode of the PPP or MP link negotiatio n

GBFD118611 GBFD118622

Abis IP SERVER( over SERVER) Enumerati E1/T1 , on Type A IP over CLIENT( E1/T1 CLIENT)

AUTHMO Validate DE Mode

ADD BTSPPPL NK(Mand atory) ADD BTSMPG RP(Mand atory) BSC6900 IMP BTSPPPL NK(Mand atory) IMP BTSMPG RP(Mand atory)

Validation mode of the PPP GBFDor MLPPP 118611 link negotiatio n

Abis IP over E1/T1

SERVER( Enumerati Server), on Type CLIENT( Client)

Validate AUTHNA user ME name

Usernam e to ADD validate, PPPLNK( for the BSC6900 Mandator PPP or y) MP link negotiatio n

GBFD118611 GBFD118622

Abis IP over String E1/T1 Type A IP over E1/T1

None

Validate AUTHNA user ME name

Usernam e to ADD validate, MPGRP( for the BSC6900 Mandator PPP or y) MP link negotiatio n

GBFD118611 GBFD118622

Abis IP over String E1/T1 Type A IP over E1/T1

None

Validate AUTHNA User ME Name

ADD BTSPPPL NK(Mand atory) ADD BTSMPG RP(Mand atory) BSC6900 IMP BTSPPPL NK(Mand atory) IMP BTSMPG RP(Mand atory)

Usernam e to validate, for the GBFDPPP or 118611 MLPPP link negotiatio n

Abis IP over E1/T1

String Type

None

Password to ADD validate, AUTHPW Validate PPPLNK( BSC6900 upon PPP D password Mandator or MP link y) negotiatio n

GBFD118611 GBFD118622

Abis IP over String E1/T1 Type A IP over E1/T1

None

Password to ADD validate, AUTHPW Validate MPGRP( BSC6900 upon PPP D password Mandator or MP link y) negotiatio n

GBFD118611 GBFD118622

Abis IP over String E1/T1 Type A IP over E1/T1

None

ADD BTSPPPL NK(Mand atory) ADD BTSMPG RP(Mand AUTHPW Validate atory) BSC6900 D Password IMP BTSPPPL NK(Mand atory) IMP BTSMPG RP(Mand atory)

Password to validate, upon PPP GBFDor MLPPP 118611 link negotiatio n

Abis IP over E1/T1

String Type

None

Validate AUTHTY protocol PE type

Type of validation protocol ADD for the BSC6900 PPPLNK( PPP or Optional) MP link negotiatio n

GBFD118611 GBFD118622

NO_V(NO Abis IP _V), over Enumerati PAP_V(P E1/T1 on Type AP_V), A IP over CHAP_V( E1/T1 CHAP_V)

Validate AUTHTY protocol PE type

Type of validation protocol ADD for the BSC6900 MPGRP( PPP or Optional) MP link negotiatio n ADD BTSPPPL NK(Optio nal) ADD BTSMPG RP(Optio BSC6900 nal) IMP BTSPPPL NK(Optio nal) IMP BTSMPG RP(Optio

GBFD118611 GBFD118622

NO_V(NO Abis IP _V), over Enumerati PAP_V(P E1/T1 on Type AP_V), A IP over CHAP_V( E1/T1 CHAP_V)

Validate AUTHTY Protocol PE Type

Type of the validation protocol for the GBFDPPP or 118611 MLPPP link negotiatio n

Abis IP over E1/T1

NO_V(No Validate), PAP_V(P Enumerati AP on Type Validate), CHAP_V( CHAP Validate)

Whether the selfnegotiatio n mode is adopted 1. When the FG2 board is used and the port type is GE, the selfnegotiatio n mode SET must be Auto ETHPOR adopted. AUTO negotiatio BSC6900 T(Optiona 2. If the n l) selfnegotiatio n mode is adopted, the FE port rate, working mode and flow control mode must be in accordan ce with the Whether Add interintersubrack ADD subrack AUTOAD path BSC6900 BRD(Opti path can DSRCON automatic onal) be added ally automatic ally

GBFD118609

IP Fault Detection Enumerati ENABLE, Based on on Type DISABLE BFD

MRFD210301

Configura NO(NO), tion Enumerati YES(YES Managem on Type ) ent

Whether to allow automatic adjustme Auto SET nt for the AUTOAD Adjust UL GCELLC uplink GBFDJULTHHY TH and BSC6900 CAMR(O threshold 115501 STF Hysteresi ptional) and s [F] hysteresis of full rate AMR call rates

AMR FR

Enumerati NO(No), on Type YES(Yes)

Whether to allow automatic adjustme Auto SET nt for the AUTOAD Adjust UL GCELLC uplink GBFDJULTHHY TH and BSC6900 CAMR(O threshold 115502 STH Hysteresi ptional) and s [H] hysteresis of half rate AMR call rates

AMR HR

Enumerati NO(No), on Type YES(Yes)

Whether Support to enable SET Auto the BSC AutoGetB OTHSOF GBFDObtaining BSC6900 to obtain tsLogFlag TPARA(O 111202 of BTS BTS logs ptional) Logs automatic ally

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

Whether SET Automatic to enable AUTONE BTSETH GBFDNegotiatio BSC6900 the autoG PORT(Op 118601 n Mode negotiatio tional) n mode

DISABLE D(Disable Abis over Enumerati d), IP on Type ENABLE D(Enable d)

The parameter specifies the work mode for the automatic download and activation of the BTS software. BTS Software Work SET Auto DL Mode for BTSAUT AUTOTY and ACT GBFDAuto BSC6900 ODLDAC PE indicates 111202 Download TINFO(O that the Activation ptional) BTS boards are download ed and activated as required. TMU Software Auto ACT indicates that only the TMU/DTM Auto AUTOUL Unlock KSW Switch LCK Auto BSC6900 SCHTSK( unlock Optional) switch

O&M of BTS

BTSAUT ODLDAC T(BTS Software Auto DL Enumerati and ACT), on Type TMUAUT OACT(TM U Software Auto ACT)

MRFD210305

Security Enumerati OFF(Off), Managem on Type ON(On) ent

Duration of time after SET Auto which the AutoUnlo PWDPOL MRFDUnlock BSC6900 locked ckTime ICY(Optio 210305 Time user is nal) unlocked automatic ally optical adaptatio n type Administr SET between AUTYPE ation unit BSC6900 OPT(Opti None high-order type onal) path and multiplex section.

Security Interval Managem Type ent

1~65535

None

AU4(AU4) Enumerati , on Type AU3(AU3)

AVer

A Interface Tag

Phase tag for GSM protocols supported by the A interface. The value SET of this BSCBASI GBFDBSC6900 parameter C(Optiona 111804 is chosen l) according to the A interface phase tag provided by the MSC. SET ALMPOR BSC6900 T(Optiona l) Alarm level for a MRFDdigital 210304 port

A Interface Protocol Process

GSM_PH ASE_1, GSM_PH Enumerati ASE_2, on Type GSM_PH ASE_2Plu s

AVOL

Alarm level

LOW(LO Faulty Enumerati W), Managem on Type HIGH(HI ent GH)

AVOL

Alarm VOL.

SET BTSENV BSC6900 ALMPOR T(Optiona l)

Alarm level. It is MRFDvalid for 210304 the digital port.

LOW(LO Faulty Enumerati W), Managem on Type HIGH(HI ent GH)

Threshold of B1 and B2 signal degrade. This parameter specifies the generatio n B1B2 threshold SET B1B2SDT signal and the BSC6900 OPT(Opti None HRD degraded recovery onal) threshold threshold of the B1B2 signal degradati on threshold in SDH frames at the optical port.

None

O1E3_R1 E4(OCCU R:1E-3, RECOVE RY:1E-4), O1E4_R1 E5(OCCU R:1E-4, RECOVE RY:1E-5), O1E5_R1 E6(OCCU R:1E-5, RECOVE RY:1E-6), O1E6_R1 Enumerati E7(OCCU on Type R:1E-6, RECOVE RY:1E-7), O1E7_R1 E8(OCCU R:1E-7, RECOVE RY:1E-8), O1E8_R1 E9(OCCU R:1E-8, RECOVE RY:1E-9), O1E9_R1 E10(OCC UR:1E-9, RECOVE

Threshold of B1 and B2 signal failure. This parameter specifies the generatio n B1B2 SET threshold B1B2SFT signal fail BSC6900 OPT(Opti and the None HRD threshold onal) recovery threshold of the B1B2 signal failure threshold in SDH frames at the optical port.

None

O1E3_R1 E4(OCCU R:1E-3, RECOVE RY:1E-4), O1E4_R1 E5(OCCU R:1E-4, RECOVE RY:1E-5), O1E5_R1 E6(OCCU R:1E-5, RECOVE RY:1E-6), O1E6_R1 Enumerati E7(OCCU on Type R:1E-6, RECOVE RY:1E-7), O1E7_R1 E8(OCCU R:1E-7, RECOVE RY:1E-8), O1E8_R1 E9(OCCU R:1E-8, RECOVE RY:1E-9), O1E9_R1 E10(OCC UR:1E-9, RECOVE

B3SDTH RD

Threshold of B3 signal degrade. This parameter specifies the generatio n B3 signal SET threshold degrade BSC6900 OPT(Opti and the None threshold onal) recovery threshold of the B3 signal degradati on threshold in SDH frames at the optical port.

None

O1E4_R1 E5(OCCU R:1E-4, RECOVE RY:1E-5), O1E5_R1 E6(OCCU R:1E-5, RECOVE RY:1E-6), O1E6_R1 E7(OCCU R:1E-6, RECOVE RY:1E-7), O1E7_R1 Enumerati E8(OCCU on Type R:1E-7, RECOVE RY:1E-8), O1E8_R1 E9(OCCU R:1E-8, RECOVE RY:1E-9), O1E9_R1 E10(OCC UR:1E-9, RECOVE RY:1E10), O1E10_R 1E11(OC CUR:1E-

Threshold of B3 signal failure. This parameter specifies the generatio n B3 signal SET B3SFTHR threshold fail BSC6900 OPT(Opti None D and the threshold onal) recovery threshold of the B3 signal failure threshold in SDH frames at the optical port.

None

O1E4_R1 E5(OCCU R:1E-4, RECOVE RY:1E-5), O1E5_R1 E6(OCCU R:1E-5, RECOVE RY:1E-6), O1E6_R1 E7(OCCU R:1E-6, RECOVE RY:1E-7), O1E7_R1 Enumerati E8(OCCU on Type R:1E-7, RECOVE RY:1E-8), O1E8_R1 E9(OCCU R:1E-8, RECOVE RY:1E-9), O1E9_R1 E10(OCC UR:1E-9, RECOVE RY:1E10), O1E10_R 1E11(OC CUR:1E-

Switch of SET Switch of BACK8K MRFDbackplane BSC6900 CLK(Opti backplane CLKSW1 210502 LINE1 onal) LINE1

BSC/RNC Enumerati OFF(OFF Clock on Type ), ON(ON)

Switch of SET Switch of BACK8K MRFDbackplane BSC6900 CLK(Opti backplane CLKSW2 210502 LINE2 onal) LINE2

BSC/RNC Enumerati OFF(OFF Clock on Type ), ON(ON)

BackupPa Backup th Path

Directory BKP for saving BSC6900 LOGDB( the Optional) backup file

GBFD111203 MRFD210305

O&M of BSC String Security Type Managem ent

None

Path of BACKUP Backup PATH File

Path (complete BKP path) of MRFDBSC6900 DB(Optio the 210301 nal) backup file

Configura tion String Managem Type ent

None

Quality threshold for determini ng that a call is disconnec ted because of poor quality. If the uplink quality or downlink quality in Bad SET the BADQUA Quality GCELLS measure GBFDLDISCTH Disconne BSC6900 OFT(Opti ment 111004 RES ction onal) reports Threshold during the period of "Timer for Bad Quality DISC Statistic" is higher than the value of this parameter before the call is disconnec

Radio Dedicated Interval Channel Type Managem ent

0~70

Whether the downlink TBF can be establishe d in advance. Downlink TBF establish ment in advance indicates Support that the SET Advance downlink BSCPSS bAdvEstD Downlink GBFDTBF is BSC6900 OFTPAR lTbf TBF establishe 114101 A(Optiona Establish d l) ment immediat ely after the MS establishe s the uplink TBF rather than establishi ng the downlink TBF after the SGSN sends the

GPRS

CLOSE(C lose), LOCALTL Enumerati LI(Local on Type TLLI Opt), ALLTLLI( All TLLI Opt)

Bar code 2 of the interface board of the BTS. This parameter is the electronic serial number of the BTS ADD standby BAKDEV Interface BSC6900 BTSESN( PTU None TAB Board Bar Optional) board. An Code 2 electronic serial number uniquely identifies an PTU board. This parameter is set before delivery.

None

String Type

None

BAKIP

Backup port IP address

IP STR address BSC6900 IPCHK(O of the ptional) backup port

GBFD118609

IP Fault IP Detection Address Based on Type BFD

None

Mask of STR BAKMAS Backup the BSC6900 IPCHK(O K port mask backup ptional) port

GBFD118609

IP Fault IP Detection Address Based on Type BFD

None

Backup BAKPWR Power SAVMET Saving HOD Method

This parameter specifies the method of saving the BTS backup power. When this parameter is set to "Turn off TRX", the BSC SET preferenti BTSBAKP ally shuts GBFDBSC6900 WR(Mand down 111605 atory) some TRXs when the BTS experienc es a power failure. When this parameter is set to "Reduce Backup Power", the BSC saves the

Active Backup Power Control

BYTRX(T urn off TRX), Enumerati BYPWR( on Type Reduce Backup Power)

Backup BAKPWR Power SAVPOLI Saving CY Policy

This parameter specifies the backup power saving policy of the BTS. When this parameter is set to "Cover Priority", the BTS SET shuts BTSBAKP down GBFDBSC6900 WR(Optio some 111605 nal) TRXs, waits for a certain period of time, and then decrease s the power of the BCCH TRX. When this parameter is set to "Capabilit y Priority", Whether the cells at the SET 1900 GCELLS BSC6900 frequency OFT(Opti support onal) high frequency 1900 Whether the cells SET at the 850 GCELLS frequency BSC6900 OFT(Opti support onal) high frequency 1900

Active Backup Power Control

BYCOVE R(Cover Priority), BYCAP(C Enumerati apability on Type Priority), BYSAVIN G(Saving Priority)

High BANDIND Band ICATOR1 Indicator 900 of Cell 1900

GBFD114401

Multiband Interval Sharing Type One BSC

0~1

High BANDIND Band ICATOR8 Indicator 50 of Cell 850

GBFD114401

Multiband Interval Sharing Type One BSC

0~1

High BANDIND Band ICATOR9 Indicator 00 of Cell 900

Whether the cells SET at the 900 GCELLS frequency GBFDBSC6900 OFT(Opti support 114401 onal) high frequency 1900

Multiband Interval Sharing Type One BSC

0~1

Duration in which intra-cell handover is forbidden after the number of consecuti Forbidden SET ve intratime after GCELLH BANTIME BSC6900 cell MAX OAD(Opti handover Times onal) s reaches the maximum . Intra-cell handover can be conducte d again only after SET Cabinet BARCOD BTSRAC Bar Code BSC6900 LST KBC(Man List datory)

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~200

List of bar codes of all the GBFDcabinets 111202 in the BTS

O&M of BTS

String Type

None

The reference BTS must ADD Referenc support BASEBTS AISSCFG GBFDe BTS BSC6900 the Um ID (Mandator 118201 Index interface y) software synchroni zation.

SoftSynchroni Interval zed Type Network

0~2047

Temperat SET BASETE ure Basis BTSAPM MPERAT for BSC6900 UBP(Opti URE Compens onal) ation

Temperat SET BASETE ure Basis BTSDPM MPERAT for BSC6900 UBP(Opti URE Compens onal) ation

Number of the temperatu re sensor correspon ding to a battery group. You can choose sensor 1 (Battery1 Temp) or sensor 2 (Battery2 Temp). If you choose sensor 1, the system automatic ally uses sensor 1 to control the temperatu re of the battery group and performs temperatu re compens Number of the temperatu re sensor correspon ding to a battery group. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode.

GBFD111202

O&M of BTS

Battery1T emp(Batt ery 1 Temperat Enumerati ure), on Type Battery2T emp(Batt ery 2 Temperat ure)

GBFD111202

O&M of BTS

Battery1T emp(Batt ery 1 Temperat Enumerati ure), on Type Battery2T emp(Batt ery 2 Temperat ure)

BATTCA PACITY

Battery Capacity

SET BTSDPM BSC6900 UBP(Opti onal)

Battery SET BATTEN Configura BTSDPM BSC6900 ABLEDIN tion UBP(Opti Enabled onal)

Battery capacity. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode. Whether the configurat ion of external battery is allowed. The value "YES" indicates that the external battery can be configure d, and the value "NO" indicates that the external battery cannot be configure d. In multimode scenario, the value of this parameter in one mode must be

GBFD111202

O&M of BTS

Interval Type

30~1000

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

SET BTSAPM BATTERY UBP(Opti Battery DISCHAR onal) Discharge BSC6900 GEDEPT SET Depth H BTSDPM UBP(Opti onal)

BATTTYP Battery E Type

SET BTSDPM BSC6900 UBP(Opti onal)

Allowed percentag e of the battery dischargin g. After the AC power supply is cut and the power of the battery is discharge d by the value of this parameter , the diesel engine is started to supply the Battery type. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode.

GBFD111202

O&M of BTS

Interval Type

0~90

GBFD111202

O&M of BTS

NO_BAT( No Storage Battery), INSIDE_B AT(Inside Enumerati Storage on Type Battery), OUTSIDE _BAT(Out side Storage Battery)

BBAP BBAPSR service VPN listening port No.

SET SCTPSR BSC6900 VPORT(O ptional)

Number of the BBAP service listening port

GBFD113725

BSC Node Interval Redunda Type ncy

1024~655 35

BBDIF

Referenc e difference between uplink and downlink levels. Up Down SET This Balance GTRXRL parameter Basic BSC6900 ALM(Opti works Differenc onal) with "Up e Down Balance Floating Range" to count uplinkdownlink

GBFD110801 GBFD110802

Processin g of Measure ment Report Interval PreType processin g of Measure ment Report

0~254

BC

Battery Capcity

Battery capacity. The battery capacity should be set according to the vendor specificati on. If it is improperl y configure SET d, the BTSAPM battery GBFDBSC6900 UBP(Opti life may 111202 onal) be shortened . In multimode scenario, the value of this parameter in one mode must be the same as the value of the

O&M of BTS

Interval Type

0~5000

BCC

BCC

Base station color code (BCC) of a cell, provided by the network planning departme nt. It is used for differentia ADD ting the MRFDBSC6900 GCELL(O neighbori 210301 ptional) ng cells using the same BCCH frequency . A BCC and a network color code (NCC) compose a base station identity

Configura tion Interval Managem Type ent

0~7

BCC

BCC

ADD GEXT2G BSC6900 CELL(Ma ndatory)

BCC

BCC

ADD GCELLQ BSC6900 UICKSET UP(Optio nal)

Base station color code (BCC) of a cell, provided by the network planning departme nt. It is used for differentia ting the neighbori ng cells using the same BCCH frequency . A BCC and a network color code (NCC) compose a base station identity BTS color code. It uniquely identifies different BTSs that are adjacent and use the same TRX.

MRFD210301

Configura tion Interval Managem Type ent

0~7

MRFD210301

Configura tion Interval Managem Type ent

0~7

BCCH

ADD BCCH GEXT2G MRFDBCCH FD BSC6900 frequency CELL(Ma 210301 of the cell ndatory)

Configura tion Interval Managem Type ent

0~1023

ADD Main Frequenc GCELLQ BCCHFR BCCH y of the GBFDBSC6900 UICKSET EQ Frequenc BCCH 110101 UP(Mand y TRX atory)

Frequenc Interval y Band Type

0~1023

Frequenc SET Frequenc y hopping GCELLH y Hopping mode of BCCHTR OPQUIC GBFDMode of BSC6900 the TRX XHP KSETUP( 113701 BCCH that Mandator TRX carries y) the BCCH Threshold for reporting the BC congestio n alarm. When the BC congestio n level exceeds the threshold, the BC congestio n alarm is reported. Threshold for clearing the BC congestio n alarm. When the BC congestio n level is below the threshold, the BC congestio n alarm is cleared.

Frequenc y Hopping NO_Hop( (RF Enumerati No hop), hopping, on Type Hop(Hop) baseband hopping)

SET BC BCCONG BSCPSS Congestio ESTALM BSC6900 OFTPAR n Alarm BOUND A(Optiona Threshold l)

GBFD510002

Gb Over FR

Interval Type

0~100

BC SET BCCONG Congestio BSCPSS ESTRES n Restore BSC6900 OFTPAR ALMBOU Alarm A(Optiona ND Threshold l)

GBFD510002

Gb Over FR

Interval Type

0~100

SET BSCPST DSCP of BCDSCP BSC6900 CDSCPM BG[QoS] AP(Optio nal)

DSCP correspon ding to GBFDthe 118603 backgrou nd service

Gb over IP

Interval Type

0~63

BCID

BC Identifier

STR FRPORT LOOP(Ma ndatory) BLK BC(Mand BSC6900 atory) ADD BC(Mand atory) ADD NSVC(Ma ndatory)

Identifies one BC at the Gb interface board. The BCID's GBFDvalue 510002 range of PEUa board is 0~255 and that of POUc board is Current

Gb Over FR

Interval Type

0~511

BCLC

limit coefficient of the battery. The maximum charging current equals the value of "Battery Current Limiting Battery SET Coefficien Current BTSAPM t" GBFDLimiting BSC6900 UBP(Opti multiplexe 111202 Coefficien onal) d by t "Battery Capacity". If the charging current is 5 A higher than the maximum charging current, the overcharg e alarm is reported. In multi-

O&M of BTS

Interval Type

5~25

BCV

SET BoostBTSAPM Charging BSC6900 UBP(Opti Voltage onal)

BE

Battery SET Configura BTSAPM BSC6900 tion UBP(Opti Enabled onal)

BoostCharging Voltage. See the vendor specificati on for the setting of this parameter . In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another Whether the configurat ion of external battery is allowed. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode.

GBFD111202

O&M of BTS

Interval Type

433~576

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

ARP1 priority in the BE service. ARP1 priority BestEffortSET weight BEARP1 ARP1 GCELLP determine PRIWEIG BSC6900 Priority SCHM(O s the HT Weight ptional) number of the budget blocks and the block schedulin ARP2 priority in the BE service. ARP2 priority BestEffortSET weight BEARP2 ARP2 GCELLP determine PRIWEIG BSC6900 Priority SCHM(O s the HT Weight ptional) number of the budget blocks and the block schedulin ARP3 priority in the BE service. ARP3 priority BestEffortSET weight BEARP3 ARP3 GCELLP determine PRIWEIG BSC6900 Priority SCHM(O s the HT Weight ptional) number of the budget blocks and the block schedulin

GBFD119902

QoS Interval ARP&TH Type P

1~10

GBFD119902

QoS Interval ARP&TH Type P

1~10

GBFD119902

QoS Interval ARP&TH Type P

1~10

DSP bearer type. MTP3: indicates that the lower layer bearer is the MTP3 used in ATM/TDM scenario; M3UA: indicates that the ADD BEARTY DSP bear lower BSC6900 N7DPC(M PE type layer andatory) bearer is the M3UA used in IP scenario; MTP3_M3 UA: indicates that the lower layer bearer is the MTP3 and M3UA used in ATM/TDM Time

GBFD111804 GBFD111806

A MTP3(MT Interface P3), Protocol M3UA(M3 Process Enumerati UA), STP(Sign on Type MTP3_M3 aling UA(MTP3 Transport and Point) M3UA)

interval for sending a handshak e message between Interval SET BSC6900 BEATSE for GBSCRE s. The GBFDNDINGDI BSC6900 Sending DGRP(Op parameter 113725 S Heartbeat tional) checks whether the communi cation among BSCs in a redundan cy group

BSC Node Interval Redunda Type ncy

1~60

BEPPERI Bep OD Period

Average period for sending SET the GCELLE measure GBFDBSC6900 GPRSPA 114201 ment RA(Optio report nal) over the EGPRS channel Number of UTRAN TDD cells that GBFDshould be 114302 included in measure ment

EGPRS

Interval Type

0~10

SET BESTTD Best TDD GCELLC DCELLN Cell BSC6900 CUTRAN UM Number SYS(Opti onal)

GSM/TDSCDMA Interval Interopera Type bility

0~3

SET GCELLH OUTRAN FDD(Opti Better 3G BET3GH onal) Cell HO BSC6900 OEN SET Allowed GCELLH OUTRAN TDD(Opti onal)

This parameter specifies whether to allow 3G better cell handover algorithm.

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Enumerati NO(No), GSM/TD- on Type YES(Yes) SCDMA Interopera bility

Whether to enable Better SET the BETTER Cell GCELLH algorithm GBFDCELLHO BSC6900 Handover OBASIC( for the 510501 EN Enable Optional) handover to a better cell

HUAWEI Enumerati NO(No), II on Type YES(Yes) Handover

Better BETTER Cell HO CELLLAS Valid TTIME Time

According to the P/N rule, if the conditions for the handover to a better cell due to interferen ce are ADD met for P G2GNCE seconds GBFDBSC6900 LL(Option within N 510501 al) seconds, the handover is triggered. This parameter specifies the number P.

HUAWEI Interval II Type Handover

1~32

Better BETTER Cell HO CELLSTA Watch TTIME Time

According to the P/N rule, if the conditions for the handover to a better cell due to interferen ce are ADD met for P G2GNCE seconds GBFDBSC6900 LL(Option within N 510501 al) seconds, the handover is triggered. This parameter specifies the number N.

HUAWEI Interval II Type Handover

1~32

Timeout times of the BFD packet. If several consecuti Detect BFDDET STR ve BFD multiplier GBFDECTCOU BSC6900 IPCHK(O packets of BFD 118609 NT ptional) are not packet received, the BFD session is set to the DOWN state. ADD BTSBFD( Mandator BFD BFD GBFDy) BFDSN Session BSC6900 Session 118609 ADD No. No. BTSIPRT BIND(Ma ndatory) Allowed fluctuation of the difference between uplink and downlink levels relative to the reference difference . If the difference between Up Down SET uplink and GBFDBFRANG Balance GTRXRL downlink 110801 BSC6900 E Floating ALM(Opti levels is GBFDRange onal) 110802 outside the fluctuation range, the uplink and downlink are considere d imbalance d. For example, assume that the Up Down

IP Fault Detection Interval Based on Type BFD

3~10

IP Fault Detection Interval Based on Type BFD

1~2

Processin g of Measure ment Report Interval PreType processin g of Measure ment Report

10~254

Switchbac k Policy of BHPREP Baseband OLICY FH Mutual Aid

In Frame BITOFFS Bit Offset ET [1/8 bit]

Mutualaid changeba ck policy of baseband frequency hopping (FH). If multiple TRXs in a baseband FH group are faulty and SET changeba GCELLC GBFDck is BSC6900 CACCES 113801 needed S(Optiona after l) mutual aid of the baseband FH TRXs occurs: If you choose ALL, mutualaid changeba ck is implemen ted after all the SET BTSEXC URSION( Bit offset Mandator in the GBFDBSC6900 y) frame of 118201 SET the BTS BSCSYN clock COFF(Ma ndatory) ARP1

TRX ALL(All), Enumerati Cooperati PART(Par on Type on t)

SoftSynchroni Interval zed Type Network

10000~10 000

priority in the Backgrou nd service. ARP1 Backgrou SET BKGARP priority nd-ARP1 GCELLP GBFD1PRIWEI BSC6900 weight Priority SCHM(O 119902 GHT determine Weight ptional) s the number of the budget blocks and the block

QoS Interval ARP&TH Type P

1~10

Backgrou BKGARP nd-ARP2 2PRIWEI Priority GHT Weight

Backgrou BKGARP nd-ARP3 3PRIWEI Priority GHT Weight

ARP2 priority in the Backgrou nd service. ARP2 SET priority GCELLP BSC6900 weight SCHM(O determine ptional) s the number of the budget blocks and the block ARP3 priority in the Backgrou nd service. ARP3 SET priority GCELLP BSC6900 weight SCHM(O determine ptional) s the number of the budget blocks and the block

GBFD119902

QoS Interval ARP&TH Type P

1~10

GBFD119902

QoS Interval ARP&TH Type P

1~10

BLKFILT ERSW

Alarm switch of blinking filter

SET ALMBLKS BSC6900 W(Option al)

Base Station Controller MRFDalarm 210304 blink filter switch

DISABLE( Faulty Enumerati Disable), Managem on Type ENABLE( ent Enable)

Alarm blink filter threshold. When the interval between the generatio n and clearance SET of an Alarm ALMBLKP alarm is MRFDBLKPRD blink BSC6900 ARA(Opti equal to 210304 threshold onal) or smaller than the alarm blink filter threshold, the alarm is filtered and not reported to the NMS.

Faulty Interval Managem Type ent

0~65534

Measure ment Observing SET period of time BLKSTAT ALMBLKS filtered MRFDwindow of BSC6900 PRD W(Option Base 210304 statistical al) Station alarm Controller alarms

Faulty Interval Managem Type ent

60~65534

Switch controlling whether Switch of SET to perform BLKSTAT statistics ALMBLKS MRFDBSC6900 statistics SW blinking W(Option 210304 of Base alarm al) Station Controller alarms

DISABLE( Faulty Enumerati Disable), Managem on Type ENABLE( ent Enable)

BLOCKR Block ETRY Retry

Retry times after the SET peer BSCNSP response GBFDBSC6900 ARA(Opti timer 510002 onal) expires during NSVC blocking Duration SET BSCNSP BSC6900 ARA(Opti onal) of the peer response GBFD510002 timer during NSVC blocking Number

Gb Over FR

Interval Type

1~6

BLOCKTI Block MER Timer

Gb Over FR

Interval Type

1~120

BMPN

BM Port No

of the port in the BM subrack ADD where ATERCO BSC6900 one end None NPATH(M of the andatory) ATER connectio n channel is located Number of the slot in the BM subrack ADD where ATERCO BSC6900 one end None NPATH(M of the andatory) ATER connectio n channel is located Number of the BM subrack ADD where ATERCO one end BSC6900 None NPATH(M of the andatory) ATER connectio n channel is located

None

Interval Type

0~335

BMSN

BM Slot No

None

Interval Type

0~5,8~27

BMSRN

BM Subrack No

None

Interval Type

0~11

Duration of the flow control protection timer Timer enabled Length of SET BMTCFC during the GBFDBM-TC BSC6900 BSCTMR( TimerLen flow 111705 Flow Optional) control Control between the TCS and the MPS/EPS subracks

GSM Flow Control

Interval Type

0~5000

BORRO Borrow WDEVIP DevIP

ADD PPPLNK( Mandator y) BSC6900 ADD MPGRP( Mandator y)

Whether to use the device IP address as the local IP address. When this parameter is set to "YES", the device IP address is used as the local IP address of the PPP link. When this parameter is set to "NO", the device IP address is not used as the local IP address of the PPP link. In this case, you

GBFD118611 GBFD118622

Abis IP over NO(NO), Enumerati E1/T1 YES(YES on Type A IP over ) E1/T1

Whether SET to report To Alarm BOXRPT( MRFDBOXFLG BSC6900 the alarm Box Flag Mandator 210304 to the y) alarm box Position of break point 1 in an RXU chain. The number of break points must not be greater than the number of RXU boards in the RXU chain. Position of break point 2 in an RXU chain. The number of break points must not be greater than the number of RXU boards in the RXU chain.

nonrpt(No Faulty Enumerati t Report), Managem on Type rpt(Report ent )

BP1

Position of Break Point 1

SET BTSBRE BSC6900 AKPOINT (Optional)

GBFD111202

O&M of BTS

0(0), 1(1), 2(2), 3(3), Enumerati 4(4), 5(5), on Type 6(6), NULL(NU LL)

BP2

Position of Break Point 2

SET BTSBRE BSC6900 AKPOINT (Optional)

GBFD111202

O&M of BTS

0(0), 1(1), 2(2), 3(3), Enumerati 4(4), 5(5), on Type 6(6), NULL(NU LL)

BQHOEN

BQ HO Allowed

Whether to enable the bad quality (BQ) handover algorithm. Whether to trigger BQ handover depends on the uplink and downlink SET transmit GCELLH quality BSC6900 OBASIC( (measure Optional) d by using BER). If the uplink or downlink BQ exceeds the BQ handover threshold, emergenc y BQ handover is triggered. The

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

BQ HO BQLASTT Valid IME Time

According to the P/N rule, if the conditions for emergenc y BQ handover are met in P of N ADD measure G2GNCE GBFDBSC6900 ment LL(Option 510501 reports, al) the handover is triggered. This parameter specifies the number P.

HUAWEI Interval II Type Handover

1~16

BQMARG BQ HO IN Margin

If ("downlink level of the neighbor cell after filtering" "downlink level of the serving cell (after ADD power G2GNCE BSC6900 control LL(Option compens al) ation)") > ("Inter-cell HO Hysteresi s" - "BQ HO Margin" + 64), the BQ handover to the neighbor

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~127

BQ HO BQSTAT Watch TIME Time

According to the P/N rule, if the conditions for emergenc y BQ handover are met in P of N ADD measure G2GNCE GBFDBSC6900 ment LL(Option 510501 reports, al) the handover is triggered. This parameter specifies the number N.

HUAWEI Interval II Type Handover

1~16

BRDCLA Board SS Class

Classes of boards STR classified MRFDBSC6900 BKP(Man according 210301 datory) to function modules SET FCSW(M andatory) SET FCCPUT BSC6900 HD(Mand atory) SET FCMSGQ THD(Man datory)

Configura SCU, tion Enumerati GCU, Managem on Type XPU, INT, ent TNU

BRDCLA Board SS Class

Classes of boards classified MRFDaccording 210301 to function modules

SCU, Configura GCU, tion Enumerati XPU, Managem on Type DPU, INT, ent TNU

BRDCLA Board SS Class

Classes of boards SET classified CPUTHD( MRFDBSC6900 according Mandator 210301 to y) function modules

SCU, Configura GCU, tion Enumerati MPU, Managem on Type GCP, ent DPU, INT, TNU

BRDCLA Board SS Class

Classes of boards ADD classified MRFDBSC6900 BRD(Man according 210301 datory) to function modules

INT, DPU, Configura XPU, tion Enumerati TNU, Managem on Type OMU, ent SAU

BRDNO

STR Number BTSLOG( Board No. BSC6900 of the Mandator board y)

GBFD111202

O&M of BTS

Interval Type

0~72

BRDNO

Number STR of the RF BTSVSW GBFDBoard No. BSC6900 front-end RTST(Opt 111202 board in ional) the BTS Upper threshold of total receive bandwidth of a board. The difference of maximum frequency and minimum frequency of TRXs GBFDon a board is 111202 converted into a bandwidth . Then the bandwidth is compared with the value of this parameter . For example, if this parameter is set to

O&M of BTS

Interval Type

0~47

ADD BTSBRD CAP(Man Receive BRDRXB datory) Bandwidt BSC6900 W ADD h BTSRXU BRD(Opti onal)

O&M of BTS

Interval Type

0~1000

BTS BRDSWT Board YPE Software Type

LOD BTSSW( BSC6900 Mandator y)

Software type of the BTS board

GBFD111202

O&M of BTS

DATM_M AIN, DATU_M AIN, DDPM_M AIN, DDPU_M AIN, DDRM_M AIN, DEMU_M AIN, DFCU_M AIN, DGPS_M AIN, Enumerati DHEU_M on Type AIN, DOMU_M AIN, DPMU_M AIN, DPTU_M AIN, DRFU_M AIN, DRFUBO OT_MAIN , DRRU_M AIN, DRRUBO OT_MAIN ,

ADD BTSBRD CAP(Man Forward BRDTXB datory) Bandwidt BSC6900 W ADD h BTSRXU BRD(Opti onal)

Upper threshold of total transmit bandwidth of the same transmit channel of a board. The difference s of maximum frequency GBFDand minimum 111202 frequency of the TRXs that have the same antenna path No. on a board are converted into bandwidth s. Then the bandwidth s are

O&M of BTS

Interval Type

0~1000

BRDTYP Board E Type

SET DPUBRD Type of MRFDBSC6900 TYPE(Ma the board 210301 ndatory)

Configura tion Enumerati DPUa, Managem on Type DPUc ent

BRDTYP Board E Type

ADD Type of MRFDBSC6900 BRD(Opti the board 210301 onal)

PEUa, FG2a, GOUa, EIUa, OIUa, POUc, FG2c, Configura GOUc, tion Enumerati XPUa, Managem on Type XPUb, ent DPUa, DPUb, DPUc, DPUd, TNUa, OMUa, OMUb, SAUa

BRDTYP Board E type.

SET ETHPOR Board BSC6900 T(Mandat type ory) ADD PPPLNK( Board BSC6900 Mandator type y)

None

None

FG2a, Enumerati GOUa, on Type FG2c, GOUc

BRDTYP Board E type

None

None

Enumerati PEUa, on Type POUc

BRDTYP Board E type

ADD MPGRP( Board BSC6900 Mandator type y)

None

None

Enumerati PEUa, on Type POUc

BRDTYP Board E type

ADD Board BSC6900 MPLNK(M type andatory)

None

None

Enumerati PEUa, on Type POUc

BrdType

Board Type

Type of RXU board. Together with the "Power Class" parameter , this parameter serves as an index ADD field and BTSBRD GBFDBSC6900 uniquely CAP(Man 111202 determine datory) s an entry of verificatio n threshold of the transmit bandwidth , receive bandwidth , and number of

O&M of BTS

MRRU, GRRU, Enumerati MRFU, on Type GRFU, BTS3900 E

BRDTYP Board E Type

Type of the board. The type can be TMU/DTM U, DTRU, DPTU, STR QTRU, BTSLOG( MRRU, GBFDBSC6900 Mandator GRRU, 111202 y) BTS3900 B, MRFU, GRFU, BTS3900 E, DRFU, DRRU, UBRI or UTRP.

O&M of BTS

TMU(TM U/DTMU), DTRU(DT RU), DPTU(DP TU), QTRU(QT RU), MRRU(M RRU), GRRU(G RRU), BTS3900 B(BTS39 Enumerati 00B), on Type MRFU(M RFU), GRFU(G RFU), BTS3900 E(BTS39 00E), DRFU(DR FU), DRRU(D RRU), UBRI(UB RI), UTRP(UT RP)

To avoid intermitte nt blinking, the switchove r cannot be performe Ring II SET d over a BREAKTI Wait Time BTSRING certain GBFDBSC6900 ME Before ATTR(Opt period of 117802 Switch ional) time when the OML is disconnec ted. That period of time is specified as ring II wait time

Fast Ring Interval Network Type Switch

0~255

SET BROADC Broadcast GCELLS ASTCON BSC6900 Content BC(Optio TENT nal)

Contents of a cell GBFDbroadcast 113602 message

Simplified Cell Any Type None Broadcast

Time SET BROADC interval Broadcast GCELLS GBFDASTINTE BSC6900 for a cell Interval BC(Optio 113602 RVAL broadcast nal) message Backup mode of the log. If "ENTIRE" is selected, all logs in the current BKP database BSC6900 LOGDB( are Optional) backed up. If "INCREM ENTAL" is selected, the logs generated after last backup

Simplified Interval Cell Type Broadcast

2~3600

BS

Backup Style

GBFD111203 MRFD210305

ENTIRE( O&M of Entire BSC Backup), Enumerati Security INCREM on Type Managem ENTAL(In ent cremental Backup)

BS-AGBLKSRES, indicating the number of the CCCH message blocks reserved for the AGCH. CCCH SET After the BSAGBL Blocks GCELLID CCCHs BSC6900 KSRES Reserved LEBASIC( are for AGCH Optional) configure d, the value of this parameter indicates the actual seizure rates of the AGCHs and the PCHs

GBFD111003 GBFD110301 GBFD110303

Radio Common Channel Managem Interval ent Type Location Updating Paging

0~7

ADD External EXTBSC( BSCDPC BSC6900 BSC DPC Mandator y)

Allow SET BSCDynS Dynamic BSCDST witchTrxP Shutdown BSC6900 PA(Optio AAllow of TRX by nal) BSC

BSCFLA G

BLK ACIC(Ma ndatory) BSC Flag BSC6900 ADD AE1T1(M andatory)

DPC of the external BSC, which is used for inter-BSC communi cation. This parameter can be represent ed in decimal, hexadeci mal, and binary. By default, this parameter is represent ed in decimal. To represent this parameter in hexadeci mal, precede this This parameter specifies whether to enable the TRX Intelligent Shutdown feature. It indicates whether the A interface E1/T1 is the primary BSC6900 or secondar

GBFD118602

A over IP

Interval Type

1~167772 15

GBFD111602

TRX Power Enumerati NO(No), Amplifier on Type YES(Yes) Intelligent Shutdown

GBFD111803 GBFD113726

A MAINBSC Interface (MAIN Circuit Enumerati BSC), Managem on Type SUBBSC( ent SUB TC Pool BSC)

ADD BSC BSCGAT GCBSAD GateWay BSC6900 EWAYIP DR(Mand IP atory)

BSC Offset ADD BSCGAT Informatio BSC6900 AISSCFG HET n (Optional) Collection End Time

BSC for Offset collecting Informatio ADD BSCGAT the inter- GBFDn BSC6900 AISSCFG HST 118201 BSC Collection (Optional) offset Start informatio Time n Uniquely ADD identifies ADJNOD BSC6900 a BSC in E(Mandat the TC ory) pool ADD GEXT2G CELL(Opt ional) BSC6900 ADD EXTBSC( Mandator y) GBFD116902 GBFD118605 GBFD113726

Gateway IP address of the BSC6900. When the BSC provides the function of simple cell broadcast , the BSC6900 sends cell broadcast message s through this IP address defined by this End time for collecting the interBSC offset informatio n Start time

GBFD113601

Short Message IP Service Address Cell Type Broadcast (TS23)

None

GBFD118201

SoftSynchroni Compoun hour, min zed d Type Network

SoftSynchroni Compoun hour, min zed d Type Network Ater Compres sion Interval Transmis Type sion IP QOS TC Pool

BSCID

BSC ID

0~15

BSCIDX

BSC Index

ID of the BSC that controls the MRFDexternal 210301 2G neighbor cell

Configura tion Interval Managem Type ent

0~15

Period for fine BSC Fine ADD BSCINCH tuning the GBFDTuning BSC6900 AISSCFG PRD BTS clock 118201 Period (Optional) between BSCs IP address of the BSC6900. If the connectio n mode of the BSC6900 and the CBC is to lead cables out of the PIU, the ADD value of GCBSAD this GBFDBSC6900 DR(Mand parameter 113601 atory) must be the same as the preset IP address of the PIU port. If the connectio n mode is to lead cables out of the XPU panel, the value of ADD BTSAUT IP OPLAN(M address andatory) of an SET interface GBFDBSC6900 BTSIP(Op board on 118601 tional) the IMP BSC6900 BTSIPPA side RA(Mand atory)

SoftSynchroni Interval zed Type Network

5~60

BSCIP

BSC IP

Short Message IP Service Address Cell Type Broadcast (TS23)

None

BSCIP

BSC IP

IP Abis over Address IP Type

None

Options BscLsStar for BSC tMode Local Switch

Condition s for enabling the function of BSC local switching. UNCOND ITIONALS TART: The function of BSC local switching SET is enabled GBFDBSC6900 BSSLS(O 117701 without ptional) restriction . ATERCO NGESTS: The function of BSC local switching is enabled when the congestio n rate of the Ater interface exceeds Unique ADD name of EXTBSC( BSC6900 the Mandator external y) BSC

BSC Local Switch

UNCOND ITIONALS TART(Un conditiona l Start), ATERCO NGESTS( Start Enumerati When on Type Ater Congests) , PREFIXN UMBER( Start by Prefix Number)

External BSCNAM BSC E Name

GBFD118621

Connectio n Inter String BSC over Type IP

None

Whether to allow highpriority calls to preempt SET the radio Preemptio OTHSOF GBFDBSCPMA BSC6900 resources n Allowed TPARA(O 115001 of lowptional) priority calls when radio resources are

Enhanced Multi Level Preceden Enumerati NO(No), ce and on Type YES(Yes) Preemptio n(EMLPP )

Whether to allow the call during an intra-BSC Preemptio emergenc SET n Allowed y BSCPMAI OTHSOF GBFDDuring BSC6900 handover RAHO TPARA(O 115001 Intra-BSC to ptional) Handover preempt the radio resources of lowpriority calls in ADD BTSMONI BSC6900 TORTS(M andatory) InBSC6900 port No. GBFDof the 114701 monitorin g timeslot

Enhanced Multi Level Preceden Enumerati NO(No), ce and on Type YES(Yes) Preemptio n(EMLPP )

BSCPN

In-BSC Port No.

SemiPermane Interval nt Type Connectio n

0~335

Port number used for the ADD communi BSCPOR GCBSAD GBFDBSC Port BSC6900 cation T DR(Mand 113601 between atory) the BSC6900 and the CBC

Short Message Service Interval Cell Type Broadcast (TS23)

0~65535

eMLPP MultiBSCPRIC Priority LASS Classes Allowed

Whether to allow the eMLPP priorities to be classified into two types: high priority and normal priority. If this SET parameter OTHSOF is set to GBFDBSC6900 TPARA(O YES, then 115001 ptional) during the resource preemptio n, the priorities of all the services are compared , and the resources are assigned to the services with a

Enhanced Multi Level Preceden Enumerati NO(No), ce and on Type YES(Yes) Preemptio n(EMLPP )

BSCQAD

Queue Allowed

Whether to allow calls to queue for SET radio OTHSOF resources GBFDBSC6900 TPARA(O when 115001 ptional) radio resources are insufficien t.

Enhanced Multi Level Preceden Enumerati NO(No), ce and on Type YES(Yes) Preemptio n(EMLPP )

Whether to allow the service Queuing during an SET Allowed intra-BSC BSCQADI OTHSOF GBFDDuring BSC6900 emergenc RAHO TPARA(O 115001 Intra-BSC y ptional) Handover handover to queue for radio resources in the SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA1 1 ptional) Reserved parameter 1 that is MRFDeffective 210301 at the BSC level

Enhanced Multi Level Preceden Enumerati NO(No), ce and on Type YES(Yes) Preemptio n(EMLPP )

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA10 10 ptional)

Reserved parameter 10 that is MRFDeffective 210301 at the BSC level Reserved parameter 11 that is MRFDeffective 210301 at the BSC level Reserved parameter 12 that is MRFDeffective 210301 at the BSC level Reserved parameter 13 that is MRFDeffective 210301 at the BSC level Reserved parameter 14 that is MRFDeffective 210301 at the BSC level Reserved parameter 15 that is MRFDeffective 210301 at the BSC level Reserved parameter 16 that is MRFDeffective 210301 at the BSC level Reserved parameter 17 that is MRFDeffective 210301 at the BSC level

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA11 11 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA12 12 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA13 13 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA14 14 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA15 15 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA16 16 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA17 17 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA18 18 ptional)

Reserved parameter 18 that is MRFDeffective 210301 at the BSC level Reserved parameter 19 that is MRFDeffective 210301 at the BSC level Reserved parameter 2 that is MRFDeffective 210301 at the BSC level Reserved parameter 20 that is MRFDeffective 210301 at the BSC level Reserved parameter 21 that is MRFDeffective 210301 at the BSC level Reserved parameter 22 that is MRFDeffective 210301 at the BSC level Reserved parameter 23 that is MRFDeffective 210301 at the BSC level Reserved parameter 24 that is MRFDeffective 210301 at the BSC level

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA19 19 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA2 2 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA20 20 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA21 21 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA22 22 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA23 23 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA24 24 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA25 25 ptional)

Reserved parameter 25 that is MRFDeffective 210301 at the BSC level Reserved parameter 26 that is MRFDeffective 210301 at the BSC level Reserved parameter 27 that is MRFDeffective 210301 at the BSC level Reserved parameter 28 that is MRFDeffective 210301 at the BSC level Reserved parameter 29 that is MRFDeffective 210301 at the BSC level Reserved parameter 3 that is MRFDeffective 210301 at the BSC level Reserved parameter 4 that is MRFDeffective 210301 at the BSC level Reserved parameter 5 that is MRFDeffective 210301 at the BSC level

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA26 26 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA27 27 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA28 28 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA29 29 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA3 3 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA4 4 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA5 5 ptional)

Configura tion Interval Managem Type ent

0~65535

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA6 6 ptional)

Reserved parameter 6 that is MRFDeffective 210301 at the BSC level Reserved parameter 7 that is MRFDeffective 210301 at the BSC level Reserved parameter 8 that is MRFDeffective 210301 at the BSC level Reserved parameter 9 that is MRFDeffective 210301 at the BSC level InBSC6900 slot No. of GBFDthe 114701 monitorin g timeslot InBSC6900 subrack GBFDNo. of the 114701 monitorin g timeslot

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA7 7 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA8 8 ptional)

Configura tion Interval Managem Type ent

0~429496 7295

SET BSCRES Reserved OTHSOF ERVEDP parameter BSC6900 TPARA(O ARA9 9 ptional)

Configura tion Interval Managem Type ent

0~65535

BSCSN

In-BSC Slot No.

ADD BTSMONI BSC6900 TORTS(M andatory)

SemiPermane Interval nt Type Connectio n

0~27

In-BSC BSCSRN Subrack No.

ADD BTSMONI BSC6900 TORTS(M andatory)

SemiPermane Interval nt Type Connectio n

0~11

In-BSC BSCSUB Sub TS Timeslot No.

ADD BTSMONI BSC6900 TORTS(M andatory)

BSC BSCSYM Symbol OFF Offset

SET BSCAISS BSC6900 (Mandator y)

InBSC6900 subtimeslot No. of the monitorin g timeslot. If the added monitorin g timeslot works at 64 kbit/s, the subtimeslots are numbered from 0. If the added monitorin g timeslot works at 32 kbit/s, the subtimeslots are numbered from 0 or 4. If the added monitorin g timeslot works at 16 kbit/s, When the BTS clock is adjusted, the offset is added to obtain better network performa nce.

GBFD114701

SemiPermane Interval nt Type Connectio n

0~7

GBFD118201

SoftSynchroni Interval zed Type Network

0~2500

BSCTID

ADD ATERE1T 1(Mandat ory) ADD ID of BSC ATERSL( in TC BSC6900 Mandator Pool y) ADD SEMILIN K(Mandat ory)

ID of the BSC at the other end of the link. In non-TC pool scenario, this parameter specifies the ID of GBFDthe 113726 primary BSC. In TC pool scenario, this parameter specifies the ID of the BSC that is at the other end of the ID of slave BSC in TC Pool

TC Pool

Interval Type

0~15

BSCTID

ID of a BSC in TC Pool

SET BSCBASI BSC6900 C(Mandat ory)

GBFD113726

TC Pool

Interval Type

1~15

BSCTS

In-BSC Timeslot No.

ADD BTSMONI BSC6900 TORTS(M andatory)

InBSC6900 timeslot GBFDNo. of the 114701 monitorin g timeslot

SemiPermane Interval nt Type Connectio n

1~31

BSCVMA BS_CV_ X MAX

This parameter is used to set the parameter BS_CV_ MAX for MS countdow n. This parameter is used for the MS to calculate SET the CV. GCELLP This GBFDBSC6900 SBASE(O parameter 114101 ptional) also determine s the duration of the timer T3198. When the MS sends one uplink RLC data block, the receiving state of this data block is

GPRS

Interval Type

0~15

Transfer BSMSPW BTS/MS RLEV Power Class

Whether to enable SET the BTS GCELLH to transfer GBFDBSC6900 OCTRL(O BTS/MS 110802 ptional) power class to the BSC

Preprocessin g of Enumerati NO(No), Measure on Type YES(Yes) ment Report

Number BSPAGB of LKSRES PAGCH Blocks

Number ADD of BSC6900 GCELL(O PAGCH ptional) blocks

MRFD210301

Configura tion Interval Managem Type ent

0~12

Number of multifram es in a cycle on a paging subchannel. In fact, this parameter specifies the number of Multipaging Frames in SET subBSPAMF a Cycle GCELLID channels BSC6900 RAMS on the LEBASIC( that a Paging Optional) paging CH channel in a cell is divided into. In an actual network, an MS does not listen to other paging subchannels but its Number BSPBCC of HBLKS PBCCH Blocks Number ADD of BSC6900 GCELL(O PBCCH ptional) blocks

GBFD110303 GBFD111003

2_M_PER IOD(2 Multifram e Period), 3_M_PER IOD(3 Multifram e Period), 4_M_PER IOD(4 Multifram e Period), 5_M_PER Paging IOD(5 Radio Multifram Common Enumerati e Period), Channel on Type 6_M_PER Managem IOD(6 ent Multifram e Period), 7_M_PER IOD(7 Multifram e Period), 8_M_PER IOD(8 Multifram e Period), 9_M_PER IOD(9 Multifram e Period)

MRFD210301

Configura tion Interval Managem Type ent

1~4

Number BSPRAC of HBLKS PRACH Blocks

Number ADD of BSC6900 GCELL(O PRACH ptional) blocks

MRFD210301

Configura tion Interval Managem Type ent

0~12

General strategy of the BSS local switching, which includes the BSC BSS local Local SET BssLsGe switching Switching BSC6900 BSSLS(O nMode and the General ptional) BTS local Strategy switching. The two functions cannot be enabled at the same time. Type of the BSS local switching with the cooperati on of the MSC. NONSUP PORT: When performin g local switching, the BSS MSCADD need not Collaborat BSSLSM GCNNOD determine ed BSS BSC6900 SCCOOP E(Optiona whether Local l) the MSC Switching allows an MS to be involved in local switching. BASIC: Assignme nt request message s and handover request message s sent by the MSC

GBFD117701 GBFD117702

BSC Local Switch BTS Local Switch

NEITHER START(N either Start), BTSPRIO RITY(BTS Priority), BSCPRIO Enumerati RITY(BS on Type C Priority), BTSONL Y(BTS Only), BSCONL Y(BSC Only)

GBFD117701 GBFD117702

BSC Local Switch BTS Local Switch

NONSUP PORT(No t Support), Enumerati BASIC(Ba on Type sic Fun), ENHANC ED(Enha nced Fun)

Whether to support the paging function of the CS domain of the A interface. Yes: the MS can be called upon paging request BSSPAGI BSS SET on the A NGCOOR Paging GCELLP interface BSC6900 DINATIO CoSBASE(O when N ordination ptional) handling the PS service; No: the MS cannot be called upon paging request on the A interface when handling the PS service.

GBFD119305 GBFD119305

BSS Paging Coordinati NO(NO), on Enumerati YES(YES BSS on Type ) Paging Coordinati on

BT

Board type

SET Type of MRFDBSC6900 CLK(Man the board 210502 datory)

PEUa, BSC/RNC Enumerati EIUa, Clock on Type OIUa, POUc

BT

Board type

CON Type of MRFDBSC6900 PATCH(M the board 210401 andatory)

SCUa, GCUa, GCGa, PEUa, FG2a, GOUa, EIUa, BSC/RNC OIUa, Software Enumerati POUc, Managem on Type FG2c, ent GOUc, XPUa, XPUb, DPUa, DPUb, DPUc, DPUd, TNUa

BT

Board type

LOD PATCH(M andatory) Type of MRFDBSC6900 LOD the board 210401 BRD(Man datory)

SCUa, GCUa, GCGa, PEUa, FG2a, GOUa, EIUa, OIUa, BSC/RNC POUc, Software Enumerati FG2c, Managem on Type GOUc, ent XPUa, XPUb, DPUa, DPUb, DPUc, DPUd, TNUa, ALL

BT

Board type

SET E1T1LOP (Mandator Board BSC6900 y) type SET E1T1(Ma ndatory)

None

None

PEUa, Enumerati POUc, on Type EIUa, OIUa

BT

Board type

LOP Board BSC6900 E1T1(Ma type ndatory)

None

None

PEUa, Enumerati POUc, on Type EIUa

BT

Board type

STR E1T1TST Board BSC6900 (Mandator type y) SET Board BSC6900 OPT(Man type datory) SET COPTLN Board BSC6900 K(Mandat type ory) ADD IPLOGIC Board BSC6900 PORT(Ma type ndatory) CHK E1T1CRS Board BSC6900 (Mandator type y)

None

None

PEUa, Enumerati POUc, on Type EIUa, OIUa Enumerati POUc, on Type OIUa

BT

Board type

None

None

BT

Board Type

None

None

Enumerati POUc, on Type OIUa

BT

Board Type

None

None

FG2a, GOUa, Enumerati FG2c, on Type GOUc, POUc

BT

Board type

None

None

Enumerati EIUa on Type

BT

Board Type

Type of the board that controls the RET antenna. 1. DATU: It may represent the DATU or the DATM and is applicable to the ADD BTS3012, BTSRET BTS3012 MRFDBSC6900 ANT(Man AE, 210602 datory) BTS3012 _II, BTS3006 C, and BTS3002 E. 2. GATM: It is applicable to the BTS3900 GSM, BTS3900 A GSM, BTS3036, and

DATU(DA TU), GATM(G ATM), DRRU(D RRU), MRRU(M Remote RRU), Enumerati Electrical MRFU(M on Type Tilt RFU), GRFU(G RFU), GRRU(G RRU), BTS3900 E(BTS39 00E)

BT

Board Type

ADD BTSANTF BSC6900 EEDERB RD(Mand atory)

Type of the newly GBFDadded 111202 antenna board

O&M of BTS

CDU(CD U), PCDU(PC DU), DCDU(D CDU), CDUC(C DUC), CDUP(C DUP), RCDU(R CDU), CDUR(C DUR), CDUE(C DUE), Enumerati EDU(EDU on Type ), PEDU(PE DU), REDU(RE DU), DEDU(DE DU), EDUC(ED UC), EDUP(ED UP), EDUR(ED UR), EDUE(ED UE), DDPM_D DPU(DDP

BT

Board Type

ADD BTSBRD( BSC6900 Mandator y)

Type of the newly GBFDadded 111202 board

O&M of BTS

BT

Board Type

Type of ADD the newly BTSRXU GBFDBSC6900 added BRD(Man 111202 RXU datory) board

O&M of BTS

PWC(PW C), EAC_EM UA(EAC_ EMUA), DTMU(DT MU), DATM_D ATU(DAT M_DATU) , NFCB(NF CB), EMU_DE MU(EMU _DEMU), Enumerati DPMU(D on Type PMU), DCBM_D COM(DC BM_DCO M), DHEU(D HEU), ECOM(E COM), MFU(MF U), MPW(MP W), MCD(MC D), IASU(IAS U), DRRU(D RRU), DRFU(DR FU), MRRU(M RRU), XRRU(XR RU), MRFU(M Enumerati RFU), on Type GRFU(G RFU), GRRU(G RRU), XRFU(XR FU), BTS3900 E(BTS39 00E)

BT

Board Type

ADD BTSTRX Type of GBFDBSC6900 BRD(Man the board 111202 datory)

O&M of BTS

TRX(TRX _DEFAUL T), TRX_GP RS(TRX_ GPRS), DRU(TRX _30), PTRX(PT RX), ETRX(ET RX), RTRX(RT RX), Enumerati DTRX(DT on Type RX), RETR(RE TR), DETR(DE TR), EETR(EE TR), PETR(PE TR), MTR(MT R), TRU(TRU /DTRU), QTRU(QT RU)

BT

Board Type

SET BTSANTF EEDERC Type of GBFDBSC6900 ONNECT( the board 111202 Mandator y)

O&M of BTS

BTCFLA G

The configurat ADD ion flag BM/TC ATERE1T specifies BSC6900 config flag 1(Mandat the ory) operation is on the BM or TC.

CDU(CD U), CDUC(C DUC), CDUP(C DUP), CDUR(C DUR), CDUE(C DUE), PCDU(PC DU), RCDU(R CDU), DCDU(D CDU), Enumerati EDU(EDU on Type ), EDUC(ED UC), EDUP(ED UP), EDUR(ED UR), EDUE(ED UE), PEDU(PE DU), REDU(RE DU), DEDU(DE DU), DDPM_D DPU(DDP

GBFD111801 GBFD113726

Ater Interface CFGBM( 4:1 Enumerati BM), Multiplexi on Type CFGTC(T ng C) TC Pool

BTCFLA G

ADD BM/TC ATERSL( BSC6900 config flag Mandator y)

BTSadjus Adjust t Voltage

SET GCELLB BSC6900 ASICPAR A(Optiona l)

Identifies the BM subrack or TC subrack of the BSC. When this parameter is set to "CFGBM", a BM signaling link is added. When this parameter is set to "GFGTC", a TC signaling link is added. This parameter specifies whether to enable the TRX Working Voltage Adjustme nt feature. When this parameter is set to YES, the BSC6900 supports the feature where the power amplifier can use different working voltages in different TRX modulatio

GBFD111801

Ater CFGBM( Interface Enumerati BM), 4:1 on Type CFGTC(T Multiplexi C) ng

GBFD111202 GBFD111611

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

BTSBAR BTS Bar CODE Code

SET BTSOML BSC6900 DETECT( Mandator y)

Bard code of BTS GBFDBBU 111202 board.

O&M of BTS

String Type

None

BTS SET BTSCOM Communi BSC6900 BTSIP(Op TYPE cation tional) Type

Communi cation GBFDtype of a 118601 BTS

LOGICIP( Logic IP), Abis over Enumerati PORTIP( IP on Type Port IP), PPP/MP( PPP/MP) LOGICIP( Logic IP), Abis over Enumerati PORTIP( IP on Type Port IP), PPP/MP( PPP/MP)

BTS IMP Communi BTSCOM Communi BTSIPPA cation GBFDBSC6900 TYPE cation RA(Mand type of a 118601 Type atory) BTS Peer equipmen t type of the BTS. This parameter indicates BTS ADD BTSDES whether GBFDDescriptio BSC6900 BTS(Opti C to 111202 n onal) connect the BTS to the BSC6900 or cascade the BTS

O&M of BTS

String Type

None

BTSDET BTS ECTSWIT Detect CH Switch

BTS detection switch. If the parameter is set to "CLOSE", the function of detecting the BTS is disabled. If the SET parameter BTSOTH is set to GBFDBSC6900 PARA(Op "OPEN", 118601 tional) the function of detecting the BTS is enabled. When the function of detecting the BTS is enabled, the BSC6900 BTS index

CLOSE(C Abis over Enumerati LOSE), IP on Type OPEN(O PEN)

BTSID

of the adjacent node to be added. ADD The ADJNOD GBFDSite Index BSC6900 parameter E(Mandat 118605 is valid ory) only when Adjacent node type is set to Abis.

IP QOS

Interval Type

0~2047

BTSID

BTS Index

Index of the BTS BTS BTSID running Index the command Number of the ADD BTS Connect BTSABIS connecte BTSIDCO BSC BTS BSC6900 HDLCPA d to the NBSC Index TH(Mand BSC. The atory) number is unique in a BSC List of LOD BTSSW( Mandator y) LOD BTSIDLS BTS BTSPAT BSC6900 T Index List CH(Mand atory) CON BTSPAT CH(Mand atory)

SET BTSEXC URSION( Mandator y) SET BSCSYN COFF(Ma ndatory) SET BTSAISS( Mandator y) ADD BTSESN( Mandator y) BSC6900 SET GMRSCO PE(Mand atory) ADD CELLBIN D2BTS(M andatory) SET BTSBAKP WR(Mand atory) SET BTSCRC 4(Mandat ory) SET BSCABIS BSC6900 PRIMAP( Mandator y)

Index of the BTS, uniquely GBFDidentifying 111202 a BTS in a BSC6900.

O&M of BTS

Interval Type

0~2047

GBFD111202

O&M of BTS

Interval Type

0~2047

GBFD118401

Abis Transmis Interval sion Type Optimizati on

0~2047

BTS indexes. You can specify multiple BTSs,sep GBFDarated by 111202 "&" and "&&". For example, "1&2&3&4 &5" or "1&&5".

O&M of BTS

Interval Type

0~2047

BTS BTSIDTY Index PE Type

Whether to collect COL offset SYNCINF informatio GBFDBSC6900 O(Mandat n by BTS 118201 ory) index or BTS name type Index SET BTSANT BSC6900 ANGLE(M andatory) of the BTS. BYNAME: query by BTS name; BYID: query by Base station index, 65535 indicate all base stations. IP address of a BTS. When "BTS Com Type" is set to "LOGICIP ", the value of the parameter is the IP address of the BTS. When "BTS Com Type" is set to "PORTIP" , the value of the parameter is the IP address of the BTS ethernet port. When

BYIDX(By SoftBTS Synchroni Enumerati Index), zed on Type BYNAME( Network By BTS Name)

BTS BTSIDTY Index PE Type

MRFD210602

BYNAME( Remote By Enumerati Electrical Name), on Type Tilt BYID(By Index)

BTSIDX

ADD Site Index BSC6900 BTSOP(M Collect andatory)

MRFD210305

Security Interval Managem Type ent

0~2047,6 5535

BTSIP

BTS IP

ADD BTSAUT OPLAN(M andatory) SET BSC6900 BTSIP(Op tional) IMP BTSIPPA RA(Mand atory)

GBFD118601

IP Abis over Address IP Type

None

Options BtsLsStar for BTS tMode Local Switch

Condition s for enabling the function of BTS local switching. UNCOND ITIONALS TART: The function of BTS local switching SET is enabled GBFDBSC6900 BSSLS(O 117702 without ptional) restriction . ABISCON GESTS: The function of BTS local switching is enabled when the congestio n rate of the Abis interface exceeds ADD Subnet BTSAUT BSC6900 mask of OPLAN(M BTS. andatory)

BTS Local Switch

UNCOND ITIONALS TART(Un conditiona l Start), ABISCON GESTS(S Enumerati tart When on Type Abis Congests) , PREFIXN UMBER( Start by Prefix Number)

BTSMAS Subnet K Mask

GBFD118601

IP Abis over Address IP Type

None

Whether to enable the BTS to preproces s measure SET BTSMES ment MR.Prepr GCELLH GBFDRPTPRE BSC6900 reports. ocessing OCTRL(O 110802 PROC This ptional) parameter determine s where to conduct power control.

BSC_Pre processin Preg(BSC processin preproces g of Enumerati sing), Measure on Type BTS_Pre ment processin Report g(BTS preproces sing)

BTSNAM BTS E Name

SET BTSEXC URSION( Mandator y) SET BSCSYN COFF(Ma ndatory) SET BTSAISS( Mandator y) ADD BTSESN( Mandator y) BSC6900 SET BSCABIS PRIMAP( Mandator y) ADD CELLBIN D2BTS(M andatory) SET BTSBAKP WR(Mand atory) SET BTSCRC 4(Mandat ory)

Name of the BTS, uniquely identifying a BTS in a BSC6900. This parameter cannot contain , ; = " ' more GBFDthan two 111202 (include two) %, more than two (include two) space, more than three (include three) +.

O&M of BTS

String Type

None

Connect BSC BTS Name.It is unique in ADD one BTSNAM Connect BTSABIS BSC.This GBFDECONBS BSC BTS BSC6900 HDLCPA parameter 118401 C Name TH(Mand cannot atory) contain ? |:<>"@ #!%^& * . [ ] / \ \\ '. of LOD List BTSSW( BTS Mandator names. y) You can LOD specify BTSNAM BTS BTSPAT multiple GBFDBSC6900 ELST Name List CH(Mand BTSs, 111202 atory) separated CON by "&". BTSPAT For CH(Mand example, atory) "Name1& If the parameter is set to "ON", all the Ping packets SET are sent. BTSPING BTS Ping BTSPING If the GBFDBSC6900 SWITCH Switch SW(Optio parameter 118601 nal) is set to "OFF", all the Ping packets are discarded .

Abis Transmis String sion Type Optimizati on

None

O&M of BTS

String Type

None

Abis over Enumerati OFF(Off), IP on Type ON(On)

This parameter specifies whether the BSC is allowed to shut down the BCCH TRX that is configure d as "Shut Down Enabled" SET BTSPOW BTS to save BTSLOC EROFFL Power-off GBFDpower BSC6900 KBCCH( OCKBCC Lock after the 111605 Mandator H BCCH BSC y) receives a power failure message from the BTS. When this parameter is set to Yes, the BSC shuts down all the TRXs

Active Backup Power Control

Enumerati NO(No), on Type YES(Yes)

BTSPWR BTS PC NUM Class

Maximum degree by which the SET BSC can GCELLP control GBFDBSC6900 WR2(Opti the power 110703 onal) of the BTS dynamical ly

Enhanced Power Interval Control Type Algorithm

1~16

Whether to specify "Power Control Switch for SET threshold BTSSAIC BTS GCELLS Adjust for GBFDPCADJS Supportin BSC6900 OFT(Opti SAIC" in 118103 WITCH g SAIC onal) the MML PC Adjust command "SET GCELLP WR3"

Network Support SAIC

Enumerati OFF(Off), on Type ON(On)

BTS BTSSWV Software ER Version

LOD BTSSW( BSC6900 Mandator y)

Software version GBFDnumber of 111202 the BTS

O&M of BTS

String Type

None

Transmis sion compress ion ratio of a BTS. 1. Modifying the settings of "Transfer s Compres s Rate" may change Transmis SET the BTSTRC sion BTSTRC bandwidth GBFDBSC6900 MPRATE Compres MPR(Man required 118401 sion Ratio datory) by the BTS. That is, the current bandwidth may be excessive or insufficien t. If the bandwidth is insufficien t, more secondar y links

Abis Transmis Interval sion Type Optimizati on

1~250

ADD BTS(Man datory) Type of BTSTYPE BTS Type BSC6900 SET the BTS BTSALM( Mandator y)

GBFD111202

ADD BTSAUT OPLAN(M andatory) Type of BTSTYPE BTS Type BSC6900 SET the BTS BTSAUT OPLANC FG(Mand atory)

GBFD510701

BTS30, BTS312, BTS3001 C, BTS3001 CP, BTS3002 C, BTS3012 A, BTS3006 A, BTS3012, BTS3006 C, BTS3002 O&M of Enumerati E, BTS on Type BTS3012 AE, BTS3012 _II, DBS3900 _GSM, BTS3900 _GSM, BTS3900 A_GSM, DBS3036, BTS3036, BTS3036 A, BTS3900 B_GSM, BTS3900 BTS3900 Compact B_GSM(B BTS TS3900B Automatic Enumerati GSM), Configura on Type BTS3900 tion and E_GSM(B Planning TS3900E GSM)

LOD BTSPAT CH(Mand atory) Type of BTSTYPE BTS Type BSC6900 CON the BTS BTSPAT CH(Mand atory)

GBFD111202

O&M of BTS

BTS3012( BTS3012) , BTS3006 C(BTS30 06C), BTS3002 E(BTS30 02E), BTS3012 AE(BTS3 012AE), BTS3012 _II(BTS30 12_II), DBS3900 Enumerati _GSM(DB on Type S3900 GSM), BTS3900 _GSM(BT S3900 GSM), BTS3900 A_GSM(B TS3900A GSM), DBS3036 (DBS303 6), BTS3036( BTS3036) , BTS3036

Time for which the Time for ADD BTS waits GBFDBTSWTR Waiting to BSC6900 BTSBFD( to restore 118609 Restore Optional) a BFD session

IP Fault Detection Interval Based on Type BFD

0~100000 0

BTTSTTY BT Test PE Type

STR BTSTST( BSC6900 Mandator y)

Type of TRX GBFDloopback 111207 test

BIULOOP (BIU Loopback Test), BTS Test Enumerati TRXSELF Function on Type TEST(TR X Self Loopback Test)

BTYPE

Battery Type

SET BTSAPM BSC6900 UBP(Opti onal)

BUILDTI ME

Ring II Try SET Rotating BTSRING BSC6900 Duration ATTR(Opt Time ional)

Battery type. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode. If the OML is not establishe d at one port after a period of time, the OML switches to another port and tries to connect to this port. That period of time is called ring II rotating duration

GBFD111202

O&M of BTS

NO_BAT( No Storage Battery), INSIDE_B AT(Inside Enumerati Storage on Type Battery), OUTSIDE _BAT(Out side Storage Battery)

GBFD117802

Fast Ring Interval Network Type Switch

10~255

BUNDLIN Bundling GFLAG Flag

Whether ADD to enable SCTPLN GBFDBSC6900 the data K(Optiona 118602 binding l) function

A over IP

NO(NO), Enumerati YES(YES on Type )

BVCI

ADD PTPBVC( Mandator PTP BVC BSC6900 y) Identifier BLK PTPBVC( Mandator

Identifies a unique GBFDPTP BVC 119001 with NSE

Gb Interface Function

Interval Type

2~65534

BVCI

ADD GCELLQ PTPBVC BSC6900 UICKSET Identifier UP(Optio nal)

BVCTF

SET BVC Flow BSSGPP Control BSC6900 ARA(Opti Timer onal)

The BSSGP virtual connectio n identifier. It is used to identify multiple BVCs that multiplexe s the NSVC. Duration of BVC flow control timer F. A cell sends the flow control message at the interval specified by this timer. for Switch

GBFD119001

Gb Interface Function

Interval Type

2~65534

GBFD119001

Gb Interface Function

Interval Type

1000~300 0

BWADJ

adjusting the dynamical bandwidth of the logical port. If this switch is turned on, the system adjusts the Auto ADD dynamical adjust IPLOGIC bandwidth GBFDBSC6900 bandwidth PORT(Ma of the 118605 switch ndatory) logical port according to the transmissi on quality of the link monitored by the IPPM. After this switch is turned on, the IPPM function must be

IP QOS

Enumerati OFF(OFF on Type ), ON(ON)

BWDCO NGBW

Backward ADD congestio TRMLOA BSC6900 n remain DTH(Opti bandwidth onal)

Backward ADD BWDCO congestio TRMLOA NGCLRB n clear BSC6900 DTH(Opti W remain onal) bandwidth

Backward ADD BWDCO congestio TRMLOA NGCLRT n clear BSC6900 DTH(Opti H remain onal) ratio

If the available backward bandwidth is less than or equal to this value, the backward congestio n alarm is emitted and backward congestio n control is striggered If the available backward bandwidth is greater than this value, the backward congestio n alarm is cleared and backward congestio n control is stopped. If the ratio of available backward bandwidth is greater than this value, the backward congestio n alarm is cleared and backward congestio n control is

GBFD118605

IP QOS

Interval Type

0~200000

GBFD118605

IP QOS

Interval Type

0~200000

GBFD118605

IP QOS

Interval Type

0~100

BWDCO NGTH

Backward ADD congestio TRMLOA BSC6900 n remain DTH(Opti ratio onal)

Backward overload ADD BWDOVL congestio TRMLOA DCLRRS BSC6900 n clear DTH(Opti VBW remain onal) bandwidth

Backward overload ADD BWDOVL congestio TRMLOA BSC6900 DCLRTH n clear DTH(Opti remain onal) ratio

If the ratio of available backward bandwidth is less than or equal to this value, the backward congestio n alarm is emitted and backward congestio n control is If the available backward bandwidth is greater than this value, the backward overload congestio n alarm is cleared and backward overload control is stopped. If the ratio of available backward bandwidth is greater than this value, the backward overload congestio n alarm is cleared and backward overload control is stopped.

GBFD118605

IP QOS

Interval Type

0~100

GBFD118605

IP QOS

Interval Type

0~200000

GBFD118605

IP QOS

Interval Type

0~100

Backward ADD overload BWDOVL TRMLOA congestio BSC6900 DRSVBW DTH(Opti n remain onal) bandwidth

Backward ADD overload BWDOVL TRMLOA congestio BSC6900 DTH DTH(Opti n remain onal) ratio

Backward ADD BWDRES handover TRMLOA BSC6900 VHOTH reserved DTH(Opti ratio onal)

Backward ADD BWDRSV handover TRMLOA BSC6900 HOBW reserved DTH(Opti bandwidth onal)

If the available backward bandwidth is less than or equal to this value, the backward overload congestio n alarm is emitted and backward overload control is triggerd. If the ratio of available backward bandwidth is less than or equal to this value, the backward overload congestio n alarm is emitted and backward overload control is triggered. Ratio of reserved backward bandwidth for handover user Reserved backward bandwidth for handover user

GBFD118605

IP QOS

Interval Type

0~200000

GBFD118605

IP QOS

Interval Type

0~100

GBFD118605

IP QOS

Interval Type

0~100

GBFD118605

IP QOS

Interval Type

0~200000

Maximum Max ADD ratio of BWMAXR bandwidth IPLOGIC the GBFDBSC6900 ATIO estimate PORT(Op estimated 118605 ratio [%] tional) bottleneck bandwidth

IP QOS

Interval Type

100~1000

ADD BWMOD Bandwidt RSCGRP Bandwidt GBFDBSC6900 E h Mode (Mandator h mode 118605 y)

IP QOS

FULL_DU PLEX(Full Enumerati Duplex), on Type HALF_DU PLEX(Hal f Duplex)

Threshold of bandwidth change based on the load control algorithm. When the system detects that the change of Load ADD the Control BWRTPT IPLOGIC available GBFDalgorithm BSC6900 H PORT(Op bandwidth 118605 BandWidt tional) exceeds h THD[%] this threshold through the IPPM, the system starts adjusting the bandwidth of the logical port.

IP QOS

Interval Type

0~100

Threshold for reporting the uplinkdownlink imbalance alarm. If the percentag e of the uplinkdownlink imbalance Up Down SET measure Balance GTRXRL BWTHD BSC6900 ment Alarm ALM(Opti reports in Threshold onal) the total valid measure ment reports is equal to or greater than this threshold, the uplinkdownlink imbalance alarm is ADD Index NCELL(M type. The andatory) BYCELLT Cell Index value can BSC6900 COL YPE Type be BYIDX SYNCINF or O(Mandat BYNAME. ory) Whether GPRS the Cell SET reselectio Reselect GCELLR n C31HYST Hysteresi BSC6900 ESELECT hysteresis s Applied PARA(Op parameter to C31 tional) is applied Criterion to the C31

GBFD110801 GBFD110802

Processin g of Measure ment Report Interval PreType processin g of Measure ment Report

20~100

MRFD210301

BYIDX(By Configura Cell tion Enumerati Index), Managem on Type BYNAME( ent By Cell Name) C31NOT USE(Not Use c31 Enumerati standard), on Type C31STAN DARD(Us e c31 standard)

GBFD114101

GPRS

Whether GPRS cell reselectio n offset is used for C32 calculatio n during Exception SET cell al Rule for GCELLR reselectio GBFDC32QUAL GPRS BSC6900 ESELECT n. If this 114101 Reselect PARA(Op parameter Offset tional) is set to 1, then only the positive hysteresis of the neighorin g cell is used in C32 ADD Cabinet CABINET BTSCABI Descriptio BSC6900 DESC NET(Opti n onal) Descriptiv e informatio GBFDn of the 111202 BTS cabinet List of all the cabinet numbers in the BTS

GPRS

Interval Type

0~1

O&M of BTS

String Type

None

CABLST

Cabinet List

SET BTSRAC BSC6900 KBC(Man datory)

GBFD111202

O&M of BTS

Interval Type

0~8

CABT

Whether ADD the added Is remote MRFDBSC6900 CAB(Man cabinet is cabinet 210301 datory) a remote cabinet

Configura NO(NO), tion Enumerati YES(YES Managem on Type ) ent

Whether to allow call reestablish ment. Burst interferen ce or blind spots due to high SET buildings Call GCELLB may lead CALLRES Reestabli GBFDBSC6900 ASICPAR to a radio TABDIS shment 110503 A(Optiona link Forbidden l) failure. If a call drop is caused by such a failure, the MS can start call reestablish ment to resume SET Calibratio Calibratio BTSCLKP GBFDBSC6900 n value of n Value ARA(Man 111202 the clock datory)

Call Enumerati NO(No), Reestabli on Type YES(Yes) shment

CALVAL

O&M of BTS

Interval Type

0~4095

CANPC

PWRC

SET GCELLC BSC6900 CCH(Opti onal)

Capacity SET CAPCOV and BTSAUT EROPTS Coverage BSC6900 OPLANC WITCH Optimize FG(Optio Switch nal)

Whether an MS uses the calculated value as the final receive level value. The calculated receive level value is the measured receive level value minus the receive level value obtained from the BCCH TRX timeslots. This parameter is a cell Whether to enable the capacity and coverage of the BTS to be automatic ally optimized according to the actual situation of the incumben t network.

GBFD113701 GBFD111101

Frequenc y Hopping (RF hopping, Enumerati NO(No), baseband on Type YES(Yes) hopping) System Informatio n Sending

GBFD510702

Compact BTS Enumerati OFF(OFF Automatic on Type ), ON(ON) Capacity Planning

Card ADD Card CARDFR GBFDFrequenc BSC6900 BTSBRD( Frequenc EATTR 111202 y Attribute Optional) y Attribute

O&M of BTS

GSM900( GSM900), DCS1800 (DCS180 Enumerati 0), on Type GSM850( GSM850), PCS1900 (PCS190

CARRYF Carry LAG Flag

Whether to indicate that the IP Path is carried on the IP logic port ADD or GBFDBSC6900 IPPATH( resource 118605 Optional) group. NULL indicate the IP Path is carried on the physics ADD IPLOGIC BSC6900 PORT(Op tional) Bearer type of GBFDthe logical 118605 port

IP QOS

NULL(NU LL), IPLGCPO RT(IP Enumerati Logic on Type Port), RSCGRP (Resourc e Group)

The bearing CARRYT type of the logic port

IP QOS

ETHER, IPLOGIC Enumerati PORT, on Type TRUNK, PPP, MP ETHPOR Enumerati T, on Type TRUNK

Port type STR Carry port of the CARRYT BSC6900 IPCHK(O type SBFD/AR ptional) P bearer Used together with "Cell Bar Qualify" to decide the priority status of a cell. Refer to GSM Rec. 04.08. Cell Bar SET Qualify Cell Bar GCELLID Cell Bar CBA BSC6900 Access LEBASIC( Access Optional) Cell selection priority Cell reselectio n priority NO NO Normal Normal NO YES Prohibited Prohibited YES NO

None

None

GBFD110401 GBFD110402

Basic Cell Selection NO(NO), Enumerati Basic Cell YES(YES on Type Re) selection

CBCINDE CBC X INDEX

ADD GCBSAD BSC6900 DR(Mand atory)

Uniquely identifying a cell GBFDbroadcast 113601 center (CBC)

Short Message Service Interval Cell Type Broadcast (TS23) Short Message IP Service Address Cell Type Broadcast (TS23)

0~3

CBCIP

CBC IP

ADD IP GCBSAD GBFDBSC6900 address DR(Mand 113601 of a CBC atory) CBC interface parameter , whose setting should be adjusted according to the actual situations. The value of this parameter must be translated into binary digits. The following describes each bit of the value: Bit 0: phase flag. The value 0 indicates phase II+; the value 1 indicates Port number at the CBC side in the communi cation with the BSC6900

None

CBCITFP CBC ITF ARA Para

ADD GCBSAD BSC6900 DR(Optio nal)

GBFD113601

Short Message Service Interval Cell Type Broadcast (TS23)

0~63

ADD CBCPOR GCBSAD CBC Port BSC6900 T DR(Mand atory)

GBFD113601

Short Message Service Interval Cell Type Broadcast (TS23)

0~65535

Duration of no cell broadcast message at the Cb interface. If the BSC6900 does not receive any message from the CBC Cb No during the Message SET preset CbNonMs GBFDDisconne BSC6900 BSCTMR( value of gTimer 113601 ction Optional) this Timer parameter , the BSC6900 considers that the connectio n with the CBC has been broken and reestablis hes a connectio n.

Short Message Service Interval Cell Type Broadcast (TS23)

5~180

CBQ

Cell Bar Qualify

Used together with "Cell Bar Access" to decide the priority status of a cell. See GSM Rec. 0408. This parameter SET does not GCELLID affect cell BSC6900 LEBASIC( reselectio Optional) n but cell selection only. Cell Bar Qualify Cell Bar Access Cell selection priority Cell reselectio n priority NO NO Normal

GBFD110401 GBFD110301

Basic Cell Selection Enumerati NO(No), Location on Type YES(Yes) Updating

CBS

ADD Consent Maximum IPLOGIC GBFDburst size BSC6900 burst size PORT(Op 118605 [Byte] (MBS) tional)

IP QOS

Interval Type

4500~327 67

Cell CbShake SET Broadcast HandTim BSC6900 BSCTMR( Handshak er Optional) e Timer

Filter SET CBSIGNL Length for GCELLH BSC6900 EN SDCCH OFITPEN CV_BEP (Optional)

Timer interval for sending handshak e message s. According to the value of this parameter , the BSC6900 regularly sends the CBC a handshak e message to decide whether the communi cation between the BSC6900 Number of enhanced measure ment reports (EMRs) sampled for averaging the CV_BEP on the SDCCH. Averaging the CV_BEP in multiple EMRs helps to prevent the incompre hensivene

GBFD113601

Short Message Service Interval Cell Type Broadcast (TS23)

1~5

GBFD117501

Enhanced Measure Interval ment Type Report(E MR)

0~31

Number of enhanced measure ment reports (EMRs) sampled for averaging Filter SET the CBTRAF Length for GCELLH CV_BEP GBFDBSC6900 FLEN TCH OFITPEN on the 117501 CV_BEP (Optional) TCH. Averaging the CV_BEP in multiple EMRs helps to prevent the incompre hensivene Country SET code, for BSCBASI MRFDBSC6900 example, C(Optiona 210301 86 for l) China

Enhanced Measure Interval ment Type Report(E MR)

0~31

CC

CC

Configura tion Interval Managem Type ent

0~65535

Whether to enable the certificate chain DISABLE: indicating Certificate SET that the CCAEnab Chain File CERTFIL MRFDBSC6900 certificate leSta Enabled E(Optiona 210305 chain is State l) disabled ENABLE: indicating that the certificate chain is enabled

DISABLE( Security Enumerati Disabled), Managem on Type ENABLE( ent Enabled)

Time interval for sending overload message s, used for the CCCH SET CCCHLO BTS to Load GCELLC GBFDADINDPR BSC6900 notify the Indication CCH(Opti 111003 D BSC6900 Period onal) of the load over a specific CCCH timeslot. See GSM Rec. 0508.

Radio Common Interval Channel Type Managem ent

0~255

SET CCCHLO CCCH GCELLC ADTHRE Load BSC6900 CCH(Opti S Threshold onal)

SET DSCP of BSCPST CCDSCP CONV[Qo BSC6900 CDSCPM S] AP(Optio nal)

ADD CCMINTE CCM BSC6900 ETHMA( RVAL Send Prid Optional)

This parameter is used by the BTS to inform the BSC of the load on a CCCH timeslot, that is, the load of the access requests on the RACH and the load of all the message s (such as paging message s and packet immediat e assignme nt message s) on the PCH. For details, DSCP correspon ding to the session service Transmis sion period of the CCM packet in the MA

GBFD111003

Radio Common Interval Channel Type Managem ent

20~100

GBFD118603

Gb over IP

Interval Type

0~63

GBFD118630

Ethernet OAM

Enumerati 10, 100, on Type 1000

Threshold of forbidding directed retry for cells. When the value of "Assignm ent Cell Load Judge Enable" in "SET GCELLC Cell SET CBASIC" CDRTTR Directed GCELLO is GBFDYFBDTH Retry BSC6900 THEXT(O ENABLE, 110607 RES Forbidden ptional) if cells Threshold support directed retry and the current cell load is greater than or equal to the value of this parameter , the BSC allocates a channel

Direct Retry

Interval Type

0~100

Offset of the measure ment report of the cells at the 1800 MHz frequency . Before cells are sequence d by priority, according SET to 1800 GCELLC CELL180 frequenci Reporting BSC6900 CUTRAN 0OFF es, the Offset SYS(Opti value of onal) this parameter must be added to the receive level value in the measure ment report of the cells at the 1800 MHz

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~7

SET 1800 GCELLC CELL180 Reporting BSC6900 CUTRAN 0THRED Threshold SYS(Opti onal)

2G CELL2GB NCELL A1BCCH BCCH

SET GCELL2 BSC6900 GBA1(Ma ndatory)

Threshold of the measure ment report of the cells at the 1800 MHz frequency . When the receive level value in the measure ment report of the cells at the 1800 MHz frequency exceeds the value of this parameter , the report takes effect. After being filtered, the BCCH frequency of a 2G neighbor cell that MSs can measure in idle mode. Recording the BCCH frequenci es of 2G neighbor cells that MSs can measure in idle mode, the BA1 table is sent in System Informatio n 2, 2bis, and 2ter.

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~7

MRFD210301

Configura tion Interval Managem Type ent

0~1023

SET CELL2GB 2GBA1 GCELL2 BSC6900 A1TAG Input Tag GBA1(Ma ndatory)

2G CELL2GB NCELL A2BCCH BCCH

SET GCELLH BSC6900 O2GBA2( Mandator y)

Whether to generate the 2G BA1 table automatic ally according to neighbor cell relations or to input the 2G BA1 table manually. Recording the BCCH frequenci es of 2G neighbor cells that MSs can measure in idle mode, the BA1 table is sent in System Informatio n 2, 2bis, BCCH frequency of a 2G neighbor cell that MSs can measure in dedicated mode. Recording the BCCH frequenci es of 2G neighbor cells that MSs can measure in dedicated mode, the BA2 table is sent in System Informatio n 5, 5bis,

MRFD210301

Configura AUTO(Au tion Enumerati to), Managem on Type MANU(M ent anu)

MRFD210301

Configura tion Interval Managem Type ent

0~1023

This parameter indicate whether to generate the 2G BA2 table automatic ally according to neighbor cell relations SET or to input GCELLH CELL2GB 2GBA2 MRFDthe 2G BSC6900 O2GBA2( A2TAG Input Tag BA2 table 210301 Mandator manually. y) Recording the BCCH frequenci es of 2G neighbor cells that MSs can measure in dedicated mode, the BA2 table is sent in System Informatio

Configura AUTO(Au tion Enumerati to), Managem on Type MANU(M ent anu)

Timeslot power attenuatio n level of the EDGE TRX in 8PSK. The attenuatio n level ranges from 0 to 50, each SET Cell 8PSK of which CELL8PS GCELLB Power correspon GBFDKPOWER BSC6900 ASICPAR Attenuatio ds to an 119115 LEVEL A(Optiona n Grade attenuatio l) n of 0.2 dB. When the EDGE TRX sends signals in 8PSK, the transmit power must be lower than the

Power Control

Interval Type

0~50

Offset applied to the receive level of a GSM900 cell in the measure ment report before prioritizing cells by frequency bands. SET Before 900 GCELLC CELL900 cells are Reporting BSC6900 CUTRAN OFF sequence Offset SYS(Opti d by onal) priority, according to frequenci es, the value of this parameter must be added to the receive level value in the

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~7

Threshold of the measure ment report of the cells at the 900 MHz frequency . The measure ment report is valid only when the SET receive 900 GCELLC CELL900 level in Reporting BSC6900 CUTRAN THRED the Threshold SYS(Opti measure onal) ment report of the GSM900 cell exceeds this threshold. After being filtered, the measure ment report is

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~7

Cell CELLBAR Access ACCESS Bar 2 Switch

Whether the cell can be added to the reselecte d candidate cell list. If this parameter is set to "NoPermit SET ", the cell GCELLS cannot be BSC6900 ERVPAR reselecte A(Optiona d as the l) candidate cell for handover. If this parameter is set to "Permit", the cell can be reselecte d as the candidate cell for handover.

GBFD111101 GBFD114101

Permit(Pe rmit Cell System Access), Informatio Enumerati NoPermit( n Sending on Type Prohibit GPRS Cell Access)

If the coverage type of a cell is outdoor coverage, the BTS detects whether the standing wave alarm is generated only when SET the CELLCO Cell GCELLO forward GBFDVERAGE Coverage BSC6900 THEXT(O power is 111202 TYPE Type ptional) greater than 35 dBm. If the coverage type of a cell is indoor coverage, the BTS detects whether the standing wave radio Even charging voltage of the battery. SET The CELLEQ Even BTSPMU battery is GBFDUCHGVO Charging BSC6900 BP(Optio charged 111202 L Voltage nal) at the voltage as specified by this parameter .

O&M of BTS

OUTDOO R_CELL( Outdoor Enumerati Cell), on Type INDOOR_ CELL(Ind oor Cell)

O&M of BTS

Interval Type

240~289

SET CELLEQ Even BTSDPM UCHGVO Charging BSC6900 UBP(Opti L Voltage onal)

SET CELLFLO Float BTSPMU ATCHGV Charging BSC6900 BP(Optio OL Voltage nal)

Even charging voltage of the battery. The battery is charged at the voltage as specified by this parameter . In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter Float charging voltage of the battery. The battery is charged at the voltage as specified by this parameter

GBFD111202

O&M of BTS

Interval Type

433~576

GBFD111202

O&M of BTS

Interval Type

240~289

Float charging voltage of the battery. The battery is charged at the voltage as specified by this parameter SET . CELLFLO Float BTSDPM In multi- GBFDATCHGV Charging BSC6900 UBP(Opti mode 111202 OL Voltage onal) scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter

O&M of BTS

Interval Type

432~575

CELLID

ADD GCELLF REQ(Man datory) ADD GCELLM AGRP(Ma ndatory) ADD GCELLO SPMAP( Mandator y) SET GCELLA MRQUL( Mandator Cell Index BSC6900 y) SET GCELLB ASICPAR A(Mandat ory) SET GCELLC CAD(Man datory) SET GCELLC CTMR(M andatory) SET GCELLC CUTRAN

Index of a cell, uniquely MRFDidentifying 210301 a cell in a BSC6900

Configura tion Interval Managem Type ent

0~2047

CELLID

ID of the cell. The SET cell ID GMRSCO cannot MRFDCell Index BSC6900 PE(Mand conflict 210301 atory) with other cell IDs in the BSC. SET GCELLH Cell Index BSC6900 OINTERR ATLDB(M andatory) Index of a cell, uniquely MRFDidentifying 211402 a cell in a BSC Index of a cell, uniquely MRFDidentifying 210301 a cell in a BSC6900

Configura tion Interval Managem Type ent

0~2047

CELLID

MBSC Interval Load Type Balancing

0~2047

CELLID

ADD BTSRET Cell Index BSC6900 ANT(Man datory)

Configura tion Interval Managem Type ent

0~2047,6 5535

CELLID

ADD BTSAUT Cell Index BSC6900 OPLAN(O ptional)

Index of a cell, uniquely MRFDidentifying 210301 a cell in a BSC6900

Configura tion Interval Managem Type ent

0~2047

CELLID

SAV GCELLTE GBFDCell Index BSC6900 MPLATE( Cell Index 111202 Mandator y) List of the userdefined neighbor cells to be measured . This parameter is represent STR ed as a GBFDBSC6900 NCS(Man character 510901 datory) string where the IDs of the cells to be measured are separated by &, such as 1&2&5.

O&M of BTS

Interval Type

0~2047

CELLIDL Cell List ST

2G/3G Neighbori ng Cell String Automatic Type Optimizati on

None

Index type of a cell SET CELLIDT Cell Index when this MRFDBSC6900 FHO(Man YPE Type command 210301 datory) is executed

Configura BYNAME( tion Enumerati By name), Managem on Type BYID(By ent index)

ADD CELLIDT Cell Index BTSRET Index type MRFDBSC6900 YPE Type ANT(Man of the cell 210301 datory) Index type of the cell. SET BYNAME: CELLIDT Cell Index BTSANT query by MRFDBSC6900 YPE Type ANGLE(M cell name; 210602 andatory) BYID: query by cell index.

BYNAME( Configura By tion Enumerati Name), Managem on Type BYID(By ent Index)

BYNAME( Remote By Enumerati Electrical Name), on Type Tilt BYID(By Index)

Cell ADD CELLINE Inner/Extr BSC6900 GCELL(M XTP a andatory) Property

CELLLAY Layer of ER the cell

ADD GEXT3G BSC6900 CELL(Opt ional)

This parameter specifies whether a cell is the OL subcell or the UL subcell. This parameter is applied to the enhanced dualband cell. Layer of the cell. If the layer of the cell is lower, it is more likely that a handover to the cell will be triggered. List of cell

GBFD114402

Enhanced Inner(Inne DualEnumerati r), Band on Type Extra(Extr Network a)

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati 1, 2, 3, 4 HUAWEI on Type II Handover

indexes. All cell indexes are combined ADD CELLLIS Cell Index as a MRFDBSC6900 GSMSCB T List character 210301 (Optional) string, separated by "&". For example, 1&2&5.

Configura tion String Managem Type ent

None

Whether an assignme nt complete message contains a cell list. According to GSM Rec. 08.08, during a channel assignme Cell List SET nt, an CellListO Send Flag MSGSOF assignme GBFDBSC6900 ptionSend in ASS TPARA(O nt 111804 CMP ptional) complete message contains a cell list only when the cell of the MS changes. For the MSCs of some vendors, however, assignme nt complete

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Maximum number of SDCCHs in the cell. Before convertin g a TCH into an SDCCH, the BSC compares the number of SDCCHs after the SET Cell conversio GCELLC CELLMA SDCCH GBFDn in the BSC6900 HMGBASI XSD Channel cell with 113001 C(Optiona Maximum "Cell l) SDCCH Channel Maximum ". If the number of SDCCHs after the conversio n in the cell exceeds this parameter , the BSC does not

SDCCH Dynamic Interval Adjustme Type nt

0~255

CELLNA ME

Cell Name

ADD GCELLF REQ(Man datory) ADD GCELLM AGRP(Ma ndatory) ADD GCELLO SPMAP( Mandator y) SET GCELLA MRQUL( Mandator BSC6900 y) SET GCELLB ASICPAR A(Mandat ory) SET GCELLC CAD(Man datory) SET GCELLC CTMR(M andatory) SET GCELLC CUTRAN SET GCELLH BSC6900 OINTERR ATLDB(M andatory) ADD BTSAUT OPLAN(M andatory) BSC6900 SAV GCELLTE MPLATE( Mandator y)

Name of a cell, uniquely MRFDidentifying 210301 a cell in a BSC6900

Configura tion String Managem Type ent

None

CELLNA ME

Cell Name

Name of a cell, uniquely MRFDidentifying 211402 a cell in a BSC Name of a cell, uniquely GBFDidentifying 111202 a cell in a BSC6900

MBSC String Load Type Balancing

None

CELLNA ME

Cell Name

O&M of BTS

String Type

None

CELLNA MELIST

List of cell names. All cell names are combined as a character string, separated by "&". ADD Cell For MRFDBSC6900 GSMSCB Name List example, 210301 (Optional) cell1&cell 2&cell5. The cell name should not contain the following character s:

Configura tion String Managem Type ent

None

Power of each passage on the MRRU in the cell. When multiple operators Cell SET are CELLOP Operator GCELLC GBFDBSC6900 configure PWRGRP Power HMGAD( 118701 d on an Group Optional) MRRU, the parameter specifies the power of each operator on the MRRU.

RAN Sharing

OP1(Oper ator 1), OP2(Oper ator 2), Enumerati OP3(Oper on Type ator 3), OP4(Oper ator 4), NONE(No t Shared)

Threshold of the downlink receive level of an overcoverage cell. If the downlink level of a cell is higher than the value of this CELLOV Cell Over SET parameter ERCVGR Coverage GCELLO and the BSC6900 XLEVDLT DL RxLev THEXT(O timing H Threshold ptional) advance (TA) is greater than the value of "Cell Over Coverage TA Threshold " in more than 20% measure ment reports, the cell is defined

GBFD110801 GBFD110802

Processin g of Measure ment Report Interval PreType processin g of Measure ment Report

0~63

Threshold of the TA of an overcoverage cell. If the downlink level of a cell is higher than the value of this parameter and the timing Cell Over SET advance GBFDCELLOV Coverage GCELLO (TA) is 110801 ERCVGT BSC6900 TA THEXT(O greater GBFDALTH Threshold ptional) than the 110802 value of "Cell Over Coverage TA Threshold " in more than 20% measure ment reports, the cell is defined as an overcoverage

Processin g of Measure ment Report Interval PreType processin g of Measure ment Report

0~63

Maximum number of reported paging overload message s in the cell. If the BSC allows the flow control on the repaging CELLPA message Cell SET GINGOV s, and the Paging GCELLS GBFDERLOAD BSC6900 number of Overload OFT(Opti 111003 COUNTE the Threshold onal) R reported paging overload message s exceeds the value of this parameter , the BSC determine s that the cell is in PCH overload state. Whether to allow the poweroff of the battery. In multimode scenario, the value of this Battery SET parameter CELLPW Power-off BTSDPM GBFDBSC6900 in one ROFFEN Allowed UBP(Opti 111202 mode State onal) must be the same as the value of the correspon ding parameter in another mode.

Radio Common Interval Channel Type Managem ent

1~20

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

SET CELLPW Battery BTSDPM ROFFVO Power-off BSC6900 UBP(Opti L Voltage onal)

2G/3G SET CELLRES Cell GCELLN ELSTRAT Reselecti BSC6900 C2PARA( EGY on Optional) Strategy

Battery power-off voltage. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode. This parameter specifies whether a 2G cell or 3G cell is selected in the inter-RAT cell reselectio n

GBFD111202

O&M of BTS

Interval Type

350~553

GBFD116201

2G(Prefer Networkence for Controlled Enumerati 2G Cell), Cell on Type 3G(Prefer Reselecti ence for on (NC2) 3G Cell)

The number of times that the downlink transmissi on quality of the MS is lower than the transmissi on quality threshold of the MS ("EDGE CELLRX Cell Rx SET GMSK QUALWO Quality GCELLN Quality GBFDRSENRA Worsen BSC6900 C2PARA( Threshold 116201 TIOTHRS Ratio Optional) ", "EDGE H Threshold 8PSK Quality Threshold ", or "GPRS Quality Threshold " by TBF type) is calculated accumulat ively. When the rate of the accumulat Informatio n about the cell scenario. It needs to be sent SET to the GCELLB BTS. CELLSCE Cell BSC6900 ASICPAR Based on NARIO Scenario A(Optiona the l) informatio n, the BTS optimizes the allocation of

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~100

GBFD510803 GBFD510804

COMMO N(COMM ON), Uplink MULTIPA EGPRS2TH(MULT A Enumerati IPATH), Downlink on Type INDOOR( EGPRS2INDOOR) A , HIGHWA Y(HIGHW AY)

This parameter specifies whether to allow a mobile phone to preferenti ally camp CELLSEL Select 3G SET on a 3G ECTAFTE Cell After GCELLC cell after GBFDBSC6900 RCALLR Call CAD(Opti a call is 114325 EL Release onal) terminate d in the areas covered by both the GSM network and the UMTS network.

Fast 3G Reselecti Enumerati NO(No), on at 2G on Type YES(Yes) CS Call Release

CELLTE MP1ALA RMH

High SET Temp BTSDPM Alarm BSC6900 UBP(Opti Assemble onal) d Battery1

CELLTE MP1ALA RML

Low SET Temp BTSDPM Alarm BSC6900 UBP(Opti Assemble onal) d Battery1

The BTS reports an alarm if the temperatu re of battery group 1 exceeds the value of this parameter . In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding The BTS reports an alarm if the temperatu re of battery group 1 is lower than the value of this parameter . In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon

MRFD210304

Faulty Interval Managem Type ent

400~790

MRFD210304

Faulty Interval Managem Type ent

-190~50

SET BTSAPM CELLTE Upper UBP(Opti MP1THR Assemble onal) BSC6900 ESHOLD d Battery SET H 1 Temp BTSDPM UBP(Opti onal)

Upper limit of the temperatu re measured by the temperatu re sensor of the battery group 1. If the measured value is greater than the value of GBFD111202 this parameter , the value of this parameter is reported. In multimode scenario, the value of this parameter in one mode must be

O&M of BTS

Interval Type

0~1000

SET BTSAPM Lower CELLTE UBP(Opti Assemble MP1THR onal) d Battery1 BSC6900 ESHOLD SET TEMP L BTSDPM Measure UBP(Opti onal)

Lower limit of the temperatu re measured by the temperatu re sensor of the battery group 1. If the measured value is smaller than the value of GBFD111202 this parameter , the value of this parameter is reported. In multimode scenario, the value of this parameter in one mode must be

O&M of BTS

Interval Type

-500~0

SET Battery BTSAPM Temperat CELLTE UBP(Opti ure MPCOMP onal) Compens BSC6900 ENABLE SET ated D BTSDPM Configure UBP(Opti Enabled onal)

Whether to allow the configurat ion of parameter s related to the temperatu re compens ation of the battery group GBFDIn multi111202 mode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

Threshold of the downlink receive level of an weakcoverage cell. If the downlink level of a cell is lower than the value of this Cell CELLWE SET parameter Weak AKCVGR GCELLO and the Coverage BSC6900 XLEVDLT THEXT(O timing DL RxLev H ptional) advance Threshold (TA) is smaller than the value of "Cell Weak Coverage TA Threshold " in more than 30% measure ment reports, the cell is

GBFD110801 GBFD110802

Processin g of Measure ment Report Interval PreType processin g of Measure ment Report

0~63

Threshold of the TA of an weakcoverage cell. If the downlink level of a cell is lower than the value of this parameter and the Cell SET timing CELLWE Weak GCELLO advance AKCVGT Coverage BSC6900 THEXT(O (TA) is ALTH TA ptional) smaller Threshold than the value of "Cell Weak Coverage TA Threshold " in more than 30% measure ment reports, the cell is defined as an

GBFD110801 GBFD110802

Processin g of Measure ment Report Interval PreType processin g of Measure ment Report

0~63

Threshold for stopping LAPD link congestio n control. This parameter cannot be set too small. If this parameter is set too small, the congestio Congestio SET CENDTH n control GBFDn End BSC6900 GTRXFC( D duration 111705 Threshold Optional) is too long, and thus the transmissi on capability of signaling links cannot be fully used. The difference between the congestio SET Certificate CERTFIL CertChain Chain File BSC6900 E(Mandat Name ory) Name of the MRFDcertificate 210305 chain file

GSM Flow Control

Interval Type

20~90

Security String Managem Type ent

None

CFGFLA G

SET BTSFMU ABP(Man datory) SET BTSNFC BBP(Man datory) SET BTSPMU BP(Mand atory) SET BTSAPM Board UBP(Man Paramete datory) r SET BSC6900 Configura BTSDAT tion UBP(Man Enabled datory) SET BTSDEM UBP(Man datory) SET BTSDHE UBP(Man datory) SET BTSDOM UBP(Man datory) SET BTSDPM

Whether to allow the configurat ion of alarm parameter s. The value "YES" indicates that the configurat ion is allowed, and the GBFDvalue 111202 "NO" indicates that the configurat ion is not allowed. If the parameter is set to "YES", all the other parameter s are reset to the default values in Indicates

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

CFGFLA G

Carry Flag

whether the IP path is SET carried on GBFDBSC6900 BTSIP(Op 118605 the IP tional) logic port or the resource group.

IP QOS

NULL(NU LL), IPLGCPO RT(IP Enumerati Logic on Type Port), RSCGRP (Resourc e Group)

BTS configurat ion modes include auto plan mode and normal mode. In auto plan mode, the user can enable the auto SET planning BTS BTSAUT CFGMOD algorithm GBFDConfigura BSC6900 OPLANC E 510701 s and tion Mode FG(Mand auto atory) optimizati on algorithm s according to the BTS type. In normal mode, the auto planning algorithm s and auto optimizati

Compact AUTO(AU BTS TOPLAN) Automatic Enumerati , Configura on Type NORMAL tion and (NORMA Planning L)

CFGSW

IMP BTSIPPA RA(Mand atory) IMP BTSVLAN (Mandator y) IMP BTSDEVI P(Mandat ory) IMP Configure BSC6900 BTSPPPL switch NK(Mand atory) IMP BTSMPG RP(Mand atory) IMP BTSMPL NK(Mand atory) IMP BTSIPRT( Mandator

CFLAG

Configura tion Switch. For this command , when Configura tion Switch is set to "ENABLE ", the other parameter s can be configure d. When Configura tion Switch is set to "DISABLE ", all the configurat ion which was imported Whether to enable the board parameter s to be configure d. If this parameter Board is set to Paramete SET "YES", r BTSCAB the user BSC6900 Configura PARA(Ma can set tion ndatory) board Enabled parameter s of the BTS cabinet. Otherwise , the user cannot set the board

GBFD111202

O&M of BTS

DISABLE( Enumerati Disable), on Type ENABLE( Enable)

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

CFLAG

Board SET Paramete BTSPOW r BSC6900 ERTYPE( Configura Mandator tion y) Enabled

CFM

ADD Confirm BSC6900 OP(Mand Password atory)

Whether to enable the board parameter s to be configure d. If this parameter is set to "YES", the user can set the cabinet power type. Otherwise , the user cannot set the cabinet power Confirm password. The confirm password is required to ensure that a correct password is

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD111203 MRFD210305

O&M of BSC Password Security None Type Managem ent

CG

ADD CCG(Man Comman datory) BSC6900 d Group SET CCGN(M andatory)

Customiz ed command group to be processe d

GBFD111203 MRFD210305

G_15, G_16, G_17, G_18, G_19, G_20, O&M of G_21, BSC G_22, Enumerati Security G_23, on Type Managem G_24, ent G_25, G_26, G_27, G_28, G_29, G_30, G_31

CG

This parameter is valid only when ADD Comman the BSC6900 OP(Optio d Group operator nal) belongs to the custom level.

GBFD111203 MRFD210305

O&M of BSC Bit Field Security Type Managem ent

G_0~0 G_1~1 G_2~2 G_3~3 G_4~4 G_5~5 G_6~6 G_7~7 G_8~8 G_9~9 G_10~10 G_11~11 G_12~12 G_13~13 G_14~14 G_15~15 G_16~16 G_17~17 G_18~18 G_19~19 G_20~20 G_21~21 G_22~22 G_23~23 G_24~24 G_25~25 G_26~26 G_27~27 G_28~28 G_29~29 G_30~30 G_31

CGET

ADD ATERSL( Congestio Optional) n End BSC6900 ADD Threshold ATERCO NSL(Opti onal)

Congestio n end threshold. If the congestio n end threshold is large, the congestio n control ends GBFDearlier. As 111203 a result, the congestio n control effect is poor. The work of the Ater signaling link is deteriorat ed.

O&M of BSC

Interval Type

20~90

CGET

Congestio n end threshold. If the congestio n end threshold is large, the congestio n control ends Congestio ADD earlier. As GBFDn End BSC6900 PBSL(Opt a result, 111203 Threshold ional) the congestio n control effect is poor. The work status of the Ater signaling link is deteriorat ed.

O&M of BSC

Interval Type

20~90

If the parameter is set to 1, it indicates that the CGI and RAC data is SET generated CGI and BTSAUT CGIRACS through RAC Plan BSC6900 OPLANC WITCH automatic Switch FG(Optio planning. nal) If the parameter is set to 0, it indicates that the data needs to be Name of the Comman SET command CGN d Group BSC6900 CCGN(O group. Name ptional) You can define the name.

GBFD510601

PICO Automatic Enumerati OFF(OFF Configura on Type ), ON(ON) tion and Planning

GBFD111203 MRFD210305

O&M of BSC String Security Type Managem ent

None

CGN

Cabinet Group No.

SET BTSIDLE BSC6900 TS(Mand atory)

CGST

Congestio ADD n Start BSC6900 ATERSL( Threshold Optional)

Number of the cabinet group where the idle timeslot is located. Congestio n start threshold. If congestio n start threshold is set to a large value, there will be a time lag in the congestio n control and the work of the signaling link gets deteriorat ed. The interval between congestio n start threshold and congestio n end threshold should not be too small.

GBFD114101

GPRS

Interval Type

0~2

GBFD111203

O&M of BSC

Interval Type

30~100

CGST

Congestio n start threshold. If congestio n start threshold is set to a large value, there will be a time lag in the congestio n control ADD and the Congestio ATERCO work of GBFDn Start BSC6900 NSL(Opti the 111203 Threshold onal) signaling link gets deteriorat ed. The interval between congestio n start threshold and congestio n end threshold should not be too small.

O&M of BSC

Interval Type

30~100

Congestio n start threshold. If congestio n start threshold is set to a large value, there will be a time lag in the congestio n control and, the Congestio ADD work of CGST n Start BSC6900 PBSL(Opt the Threshold ional) signaling link gets deteriorat ed. The interval between congestio n start threshold and congestio n end threshold should not be too small. This parameter indicates the geographi cal relationshi p between Chain ADD the CHAINNC Neighbou G2GNCE neighbori BSC6900 ELLTYPE r Cell LL(Option ng cell Type al) and the serving cell. In the BSC6900, if direction A is selected, then the reverse direction

GBFD111203

O&M of BSC

Interval Type

30~100

GBFD510103

QUICK_H O_NCELL _TYPE_A (QUICK_ HO_NCE LL_TYPE Chain Enumerati _A), Cell on Type QUICK_H Handover O_NCELL _TYPE_B (QUICK_ HO_NCE LL_TYPE _B)

Combinati on type of chains. "CHAINT ORING" indicates that one chain CBN changes CHAINTO Combine BTSRXU GBFDBSC6900 to a ring, RING Type CHAIN(M 111202 and andatory) "COMBIN ECHAINS " indicates that two chains are combined into one Channel assignme nt priority of the cell If this parameter is set to CAPABILI TY, the factors are listed as follows in a descendin g order of SET priority: GCELLC capacity GBFDBSC6900 HMGBASI 111005 factors, C(Optiona quality l) factors, PS cooperati on factors, and managem ent factors. If this parameter is set to QUALITY, the factors

O&M of BTS

CHAINTO RING(Ch ainToRing Enumerati ), on Type COMBIN ECHAINS (Combine Chains)

CHALLO Channel CSTRAT Allocate EGY Strategy

CAPABILI TY(Capab ility preferred) , QUALITY( Quality Enhanced preferred) Channel , Enumerati Assignme PSRELAT on Type nt IVELY(PS Algorithm relatively preferred) , PSABSO LUTELY( PS absolutely preferred)

This parameter specifies the proportion of available PDCHs in a cell. When the proportion of available PDCHs in PDCH the cell is Available SET lower CHANFA Threshold GCELLS than this ULTALM BSC6900 None of OFT(Opti threshold, PDCHTH Channel onal) the BSC Failure generates an alarm. When the proportion of available PDCHs in the cell is higher than or equal to this threshold, the BSC generates

None

Interval Type

0~100

This parameter determine s whether to activate the function of monitorin g the failure of logical Monitorin SET channels CHANFA g Alarm GCELLS in a cell. GBFDULTALM Switch for BSC6900 OFT(Opti When this 111203 SWITCH Channel onal) function is Failure activated and the proportion of faulty logical channels in the cell exceeds a predefine d threshold, the BSC

O&M of BSC

Enumerati OFF(Off), on Type ON(On)

TCH Available SET CHANFA Threshold GCELLS ULTALMT BSC6900 of OFT(Opti CHTH Channel onal) Failure

CHANID

Chan ID

SET GCELLS BC(Optio nal) BSC6900 ADD GSMSCB (Mandator y)

This parameter specifies the proportion of available TCHs in a cell. When the proportion of available TCHs in the cell is lower than this threshold, the BSC generates an alarm. When the proportion of available TCHs in the cell is higher than or equal to this threshold, the BSC generates Message Identifier of a simple cell broadcast message. This is a key parameter for adding a simple cell broadcast message. You can use "DSP GSMSCB " to query and obtain the value of this

GBFD111203

O&M of BSC

Interval Type

0~100

GBFD113602

Simplified Interval Cell Type Broadcast

0~65535

Whether to measure the channel interferen ce during channel assignme nt. If this parameter is set to NO, the BSC does not Active CH SET measure CHANINT Interf. GCELLC the GBFDERMESA BSC6900 Meas.Allo HMGAD( channel 111005 LLOW wed Optional) interferen ce or send an interferen ce indication during channel assignme nt. If this parameter is set to YES, the BSC measures the

Enhanced Channel Enumerati NO(No), Assignme on Type YES(Yes) nt Algorithm

Channel CHANNE Rate LRATEC Type ODE Decode Expand

When the value of this parameter is YES, if the assignme nt request message sent by the MSC contains the channel rate type SET indicating AITFOTH the GBFDBSC6900 PARA(Op support of 111804 tional) both full and half rates, and contains the speech version indicating the selection of full rate speech version only or half rate speech

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

This parameter is used to check whether the Abis timeslot for the PDCH is faulty. When the PDCH out-ofSET Out-ofsynchroni CHANPD GCELLS Synchroni BSC6900 None zation OUTTIME OFT(Opti zation period of onal) Period the PDCH primary link exceeds the value of this parameter , the Abis timeslot for the PDCH is regarded Number of ping check timeouts. The ADD parameter GBFDBSC6900 IPPATH( indicates 118605 Optional) the number of timeout record failures.

None

Interval Type

1~64

Ping CHECKC Check OUNT Timeout Counts

IP QOS

Interval Type

1~5

Whether to enable the BSC to check automatic ally whether a BTS is connecte d to a proper E1 port in the EIUa. If a BTS is connecte Auto SET d to an E1 Checking Check of OTHSOF port MRFDBTSConn BTS BSC6900 TPARA(O configure 210206 ection Connectio ptional) d for n Port another BTS in the EIUa, the BTS cannot be reset automatic ally after the BTS is initialized. Thus, the data configurat ions on

Tree Enumerati NO(No), Topology on Type YES(Yes)

Alarm mode of the ANT_A tributary of an RXU board. There are three alarm modes. Alarm mode 1 has only ANT_A SET one type ALD BTSRXU of alarms. ChkModA Current BSC6900 BP(Optio The alarm Detection nal) current is Mode fixed and greater than the normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical

GBFD111202 MRFD210601

O&M of BTS MODE1( Connectio Mode 1), n with Enumerati MODE2( TMA on Type Mode 2), (Tower MODE3( Mounted Mode 3) Amplifier)

Alarm mode of the ANT_B tributary of an RXU board. There are three alarm modes. Alarm mode 1 has only ANT_B SET one type ALD BTSRXU of alarms. ChkModB Current BSC6900 BP(Optio The alarm Detection nal) current is Mode fixed and greater than the normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical Detection

GBFD111202 MRFD210601

O&M of BTS MODE1( Connectio Mode 1), n with Enumerati MODE2( TMA on Type Mode 2), (Tower MODE3( Mounted Mode 3) Amplifier)

CHKN

Check Index

index. The index is a STR unique GBFDBSC6900 IPCHK(O value 118609 ptional) ranging from 0 to 511 if it is not specified. ADD IPPATHBI Detection GBFDBSC6900 ND(Mand index 118609 atory)

IP Fault Detection Interval Based on Type BFD

0~511

CHKN

Check Index

IP Fault Detection Interval Based on Type BFD

0~511

Total number of times that SET the BTS Check CHKOFF BTSAIRC checks GBFDTimes for BSC6900 TIMES ON(Optio whether 111202 Off nal) to switch off the air conditione r Total number of times that SET the BTS Check CHKONTI BTSAIRC checks GBFDTimes for BSC6900 MES ON(Optio whether 111202 On nal) to switch on the air conditione r

O&M of BTS

Interval Type

5~20

O&M of BTS

Interval Type

5~20

Whether Calculate ADD to perform checksum CHKSUM SCTPLN checksum GBFDwhen BSC6900 RX K(Optiona when 118602 receive l) receiving message message

A over IP

NO(NO), Enumerati YES(YES on Type )

Whether Calculate ADD to perform checksum CHKSUM SCTPLN checksum GBFDwhen BSC6900 TX K(Optiona when 118602 send l) sending message message

A over IP

NO(NO), Enumerati YES(YES on Type )

Checksu m arithmetic type. According to the RFC4960, the ADD Checksu ALDER32 CHKSUM SCTPLN m BSC6900 algorithm TYPE K(Optiona arithmetic is not l) applicable to the SCTP checksum . The CRC32 is recomme nded. Type of the detection STR that is CHKTYP Check BSC6900 IPCHK(M performe E type andatory) d between the BSC and the STR CHLDUR Duration< BTSTST( BSC6900 Duration ATH hour> Mandator y)

GBFD118602

ALDER32 (ALDER3 Enumerati A over IP 2), on Type CRC32(C RC32)

GBFD118609

IP Fault SBFD, Detection Enumerati ARP, Based on on Type MBFD BFD

GBFD111207

BTS Test Interval Function Type

0~12

CHNNO

Channel No.

SET BTSCHN BSC6900 FALLBAC K(Mandat ory)

Number of the MRFDchannel in 210301 the TRX

Configura tion Interval Managem Type ent

1~7

CHNNO

Channel No.

SET TCPLYV BSC6900 OICE(Ma ndatory)

Timeslot for playing sound

GBFD111203

O&M of BSC

Interval Type

0~169

CHNO

Channel No.

SET FHO(Man datory) SET GTRXCH ANHOP( Mandator y) SET GTRXCH BSC6900 AN(Mand atory) SET GTRXCH ANADMS TAT(Man datory) STR BTSTST( Mandator

Number of the MRFDchannel in 210301 the TRX

Configura tion Interval Managem Type ent

0~7

STR CHNTST Channel BTSTST( BSC6900 TYPE Test Type Mandator y)

Type of channel GBFDloopback 111207 test

TRXRFS ELFLOO P(TRX RF Self Loopback Test), BIULOOP (BIU Loopback Test), BTS Test Enumerati BTSSPEE Function on Type CHLOOP( BTS Speech Loopback Test), TRXSPE ECHLOO P(TRX Speech Loopback

CHNTYP Channel E Type

Channel type of the timeslot on the TRX. The channel type of timeslot 0 must not be set, SET because BTSCHN MRFDthe BSC6900 FALLBAC combined 210301 K(Mandat BCCH is ory) configure d by default. The channel type of other timeslots can be set to fullrate TCH

FULLTCH Configura (FULLTC tion Enumerati H), Managem on Type HALFTC ent H(HALFT CH)

Whether an assignme nt ChosenC SET complete ChosenC h Send MSGSOF message GBFDhInAssC BSC6900 Flag in TPARA(O contains 111804 mp ASS CMP ptional) the informatio n element of Chosen Channel

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether a handover ChosenC perform SET ChosenC h Send message MSGSOF GBFDhInHoPerf Flag in BSC6900 contains TPARA(O 111804 orm HO the ptional) Perform informatio n element of Chosen Channel

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether an HO REQ ACK ChosenC SET message ChosenC h Send MSGSOF contains GBFDhInHoReq Flag in BSC6900 TPARA(O the 111804 Ack HO REQ ptional) informatio ACK n element of Chosen Channel

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether an encryptio n complete ChosenE ChosenE SET message ncrypAlg ncrypAlgI MSGSOF contains GBFDSend Flag BSC6900 nCiphCm TPARA(O the 111804 in Cipher p ptional) informatio CMP n element of Chosen Encryptio n Algorithm

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether a handover performe d ChosenE ChosenE SET message ncrypAlg ncrypAlgI MSGSOF contains GBFDSend Flag BSC6900 nHoPerfor TPARA(O the 111804 in HO m ptional) informatio Perform n element of Chosen Encryptio n Algorithm

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether an assignme nt complete ChosenE SET message ChosenE ncrypAlg MSGSOF contains GBFDncrypAloI Send Flag BSC6900 TPARA(O the 111804 nAssCmp in ASS ptional) informatio CMP n element of Chosen Encryptio n Algorithm

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether an HO REQ ACK message ChosenE ChosenE SET contains ncrypAlg ncrypAloI MSGSOF the GBFDSend Flag BSC6900 nHoReqA TPARA(O informatio 111804 in HO ck ptional) n element REQ ACK of Chosen Encryptio n Algorithm

A Interface Protocol Process

NOSENDI NG(Force NO Sending), SYSTEM Enumerati OPT(Syst on Type em Optimizati on), SENDING (Force Sending)

Channel CHPWRI Assign NSUFFAL Allow for LOWED Insuff Power

SET GCELLC BSC6900 HMGAD( Optional)

CHRCOL PS CHR LECTSWI Collect TCH Switch

SET GPSCHR BSC6900 SCOPE( Optional)

CHREQC SMAXMS GNUMIN PERIOD

Max CS SET CHAN BSCFCP BSC6900 REQ Num ARA(Opti in Period onal)

Whether to allow a multidensity TRX board, that uses the dynamic power sharing algorithm to assign channels, to assign a channel to an MS when the remaining power on the multidensity TRX board is less than the power required by the MS. If this parameter is set to YES, a multidensity This parameter indicates whether to collect CHR logs for a specified object. Maximum number of allowable CS domain channel request message s within the value of "CHAN REQ Statistical Period"

GBFD111005

Enhanced Channel Enumerati NO(No), Assignme on Type YES(Yes) nt Algorithm

None

None

Enumerati OFF(OFF on Type ), ON(ON)

GBFD111705

GSM Flow Control

Interval Type

10~800

Average number of allowable PS domain CHREQP SET channel Average SAVGMS BSCFCP request GBFDPS CHAN BSC6900 GNUMIN ARA(Opti message 111705 REQ Num PERIOD onal) s within the value of "CHAN REQ Statistical Period" Statistic period of the arrival rate of channel request message s. Within the preset value of this parameter , the BSC6900 counts CHAN SET the CHREQS REQ BSCFCP number of GBFDTATPERI BSC6900 Statistical ARA(Opti channel 111705 OD Period onal) request message s. Once the current total number of times exceeds the value of the allowable number of channel request message

GSM Flow Control

Interval Type

10~800

GSM Flow Control

Interval Type

100~6000 00

Type and function of the channel Combined BCCH+7 TCH Main BCCH+S DCCH/8+ 6TCH Main SET BCCH+2 GTRXCH SDCCH/8 MRFDBSC6900 AN(Optio +5TCH 210301 nal) Main BCCH+S DCCH/8+ extended BCCH (BCH)+5T CH Main BCCH+S DCCH/8+ extended BCCH (BCH)+T CH+exten

CHTYPE

Channel Type

TCHFR(T CH Full Rate), TCHHR(T CH Half Rate), SDCCH8( SDCCH8) , MBCCH( Main BCCH), CBCCH( Combined BCCH), Configura BCH(BCH tion Enumerati ), Managem on Type BCCH_C ent BCH(BCC H+CBCH) , SDCCH_ CBCH(SD CCH+CB CH), PBCCH_ PDTCH(P BCCH+P DTCH), PCCCH_ PDTCH(P CCCH+P DTCH), PDTCH(P

CI

Cell CI

ADD GCELL(M andatory) ADD GEXT2G CELL(Ma ndatory) ADD GEXT3G CELL(Ma ndatory) SET FHO(Man BSC6900 datory) ADD BTSAUT OPLAN(M andatory) SET BTSAUT OPLANC FG(Optio nal) ADD GCELLQ UICKSET UP(Mand

CI1

Cell CI

Identity code of a cell, A cell is a wireless coverage area identified by a base station identity code and a global cell identificati on. Can be input in hexadeci mal format. The hexadeci mal format is H'****, for example, Cell identity code. The cell is a radio SET coverage BTSAUT area that BSC6900 OPLANC is FG(Optio identified nal) by the BTS identity code and global cell identity

MRFD210301

Configura tion Interval Managem Type ent

0~65535

MRFD210301

Configura tion Interval Managem Type ent

0~65535

CIC

CIC

CIC

CIC

Indicates the A interface CIC. When operation mode is set to OPC BLK index, BSC6900 ACIC(Ma DPC ndatory) group index, BSC ID, or CIC, the parameter is mandator y. The parameter Indicates the Pb interface CIC. If the search object mode is set to search by BLK the BSC6900 PBCIC(M specified andatory) No., the parameter is mandator y. The parameter supports multiple values.

GBFD111803

A Interface Interval Circuit Type Managem ent

0~65535

GBFD111203

O&M of BSC

Interval Type

0~65535

Number of SET Different CicDMute BSCBASI Frames in BSC6900 DifCnt C(Optiona CIC Onel) Way Mute Detection

CIC Downlink SET CicDMute One-Way BSCBASI BSC6900 Period Mute C(Optiona Detection l) Period

CIC Downlink SET CicDMute One-Way BSCBASI BSC6900 Switch Mute C(Optiona Detection l) Switch

The TC DSP compares neighbori ng speech frame samples after the CIC downlink one-way mute detection is enabled. When the number of times with different results exceeds the value of this parameter , it is regarded that no one-way mute event occurs for the current This parameter indicates the period of completin g a CIC downlink one-way mute detection of each port. This parameter determine s whether the CIC downlink one-way mute detection is enabled.

GBFD111803

A Interface Interval Circuit Type Managem ent

0~160

GBFD111803

A Interface Interval Circuit Type Managem ent

1~12

GBFD111803

A Interface Enumerati OFF(Off), Circuit on Type ON(On) Managem ent

CIC Downlink SET CicDMute One-Way BSCBASI BSC6900 Thre Mute C(Optiona Detection l) Threshold

CIC Downlink SET CicDMute One-Way BSCBASI BSC6900 Time Mute C(Optiona Detection l) Duration

This parameter indicates the proportion GBFDof one111803 way mute CICs in all available CICs over a port. If oneway mute frames occur for the duration greater than "CIC Downlink One-Way Mute GBFDDetection 111803 Duration", then it is regarded that a oneway mute event occurs for the current call.

A Interface Interval Circuit Type Managem ent

1~100

A Interface Interval Circuit Type Managem ent

1~60

Whether an assignme nt failure message contains CIC Pool SET the CicPoolIn Send Flag MSGSOF GBFDBSC6900 informatio AssFail in ASS TPARA(O 111804 n element Fail ptional) of Circuit Pool. The default value of the circuit pool is 27.

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether an HO FAIL message contains SET the the CIC Pool CicPoolIn MSGSOF informatio GBFDSend Flag BSC6900 HoFail TPARA(O n element 111804 in HO Fail ptional) of Circuit Pool. The default value of the circuit pool is 27.

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether an assignme nt failure message contains CIC Pool SET the the CicPoolLi List Send MSGSOF informatio GBFDstInAssFa BSC6900 Flag in TPARA(O n element 111804 il ASS Fail ptional) of Circuit Pool List. The default value of the circuit pool is 27.

A Interface Protocol Process

NOTSEN DING(Not sending), SENDING PRO(sen ding Enumerati according on Type to protocol), SENDING (unconditi onally sending)

Whether an HO FAIL message contains the the CIC Pool SET informatio CicPoolLi List Send MSGSOF GBFDBSC6900 n element stInHoFail Flag in TPARA(O 111804 of Circuit HO Fail ptional) Pool List. The default value of the circuit pool is 27.

A Interface Protocol Process

NOTSEN DING(Not sending), SENDING PRO(sen ding Enumerati according on Type to protocol), SENDING (unconditi onally sending)

Whether an assignme nt complete message CIC Pool SET contains CicPoolS Send Flag MSGSOF the GBFDendFlagIn BSC6900 in ASS TPARA(O informatio 111804 AssCmp CMP ptional) n element of Circuit Pool. The default value of the circuit pool is 27.

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether an HO REQ ACK message contains CIC Pool SET the CicPoolS Send Flag MSGSOF informatio GBFDendFlagIn BSC6900 in HO TPARA(O n element 111804 HoAck REQ ACK ptional) of Circuit Pool. The default value of the circuit pool is 27.

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

CIR

ADD Bandwidt IPLOGIC h BSC6900 PORT(Op [64kbps] tional)

Bandwidt h of the GBFDlogical 118605 port

IP QOS

Interval Type

1~1562

C/I CIRESTV Estimate ALUE Value

This parameter specifies the estimated carrier-tointerferen ce ratio of SET a new GCELLC GBFDBSC6900 call. It is HMGAD( 111005 used for Optional) the Huawei power control algorithm III to calculate the power

Enhanced Channel Interval Assignme Type nt Algorithm

0~22

CIUSLOT Slot No. NO

ADD DXXCON BSC6900 NECT(Ma ndatory)

CIUSUBR Subrack ACKNO No.

ADD DXXCON BSC6900 NECT(Ma ndatory)

Slot number of the BSC6900 board that is connecte ds to the BTS Subrack number of the BSC6900 board that is connecte d to the DXX

GBFD111202

O&M of BTS

Interval Type

0~27

GBFD111202

O&M of BTS

Interval Type

0~11

Support CLASS11 Class11 DTM DTM

Whether the cell supports SET the MS GCELLG with the GBFDBSC6900 PRS(Opti DTM multi- 119403 onal) timeslot capability of class 11

Class11 DTM

UNSUPP ORT(Not Enumerati Support), on Type SUPPOR T(Support )

Whether to enable the BSC to include the 3G classmark informatio Classmar SET n element CLASSM k Enquiry OTHSOF in the GBFDARKQUE BSC6900 With 3G TPARA(O Classmar 110501 RY Request ptional) k Request message that the BSC forwards from the MSC to an MS

Call Control

Enumerati NO(No), on Type YES(Yes)

CLEART HD

GBFDError ADD Error 118611 clear BSC6900 MPGRP( clear GBFDthreshold Optional) threshold. 118622

ERR_PF M_1E6(R ECOVER Y:1E-6), ERR_PF M_5E6(R ECOVER Y:5E-6), ERR_PF M_1E5(R ECOVER Y:1E-5), Abis IP ERR_PF over Enumerati M_5E5(R E1/T1 on Type ECOVER A IP over Y:5E-5), E1/T1 ERR_PF M_1E4(R ECOVER Y:1E-4), ERR_PF M_5E4(R ECOVER Y:5E-4), ERR_PF M_1E3(R ECOVER Y:1E-3) INCLK(Int ernal Clock), BSCCLK( Trace BSC Clock), EXCLK(E xternal Synchro Clock), IPCLK(IP Enumerati Clock), on Type TRANSC LK(Trace Trans Clock), GPSCLK( Trace GPS Clock), UMCLK(U m Clock), PEERCL K(PEER

Clock CLKMOD Mode

SET BTSCLKP Clock BSC6900 ARA(Man mode datory)

GBFD111202

O&M of BTS

Clock CLKPRTT Protocol YPE Type

SET BTSIPCL BSC6900 KPARA(O ptional)

Type of the clock protocol GBFDfor the IP 111202 clock server

O&M of BTS

HW_DEFI NED(Hua Enumerati wei Useron Type defined), PTP(PTP Protocol)

Clock CLKTYPE board type

SET Type of CLKTYPE MRFDBSC6900 the clock (Mandator 210502 board y)

BSC/RNC Enumerati GCUa, Clock on Type GCGa

ClkType

Clock Type

Clock mode of the BTS. If this parameter is set to INT_CLK, the BTS does not track any external clock. The internal high precision SET clock BTSCLK( works in MRFDBSC6900 Mandator free-run 210501 y) mode. If this parameter is set to TRCBSC _CLK, the BTS tracks the clock signals received from the BSC. If this parameter is set to

INT_CLK( Internal Clock), TRCBSC _CLK(Tra ce BSC Clock), EXTSYN_ CLK(Exte rnal Sync clock), IP_TIME(I P Clock), BTS/Nod Enumerati IP_TRAN eB Clock on Type SFER(Tra ce Transport Clock), TRCGPS _CLK(Tra ce GPS Clock), UM_CLK( Um Clock), PEER_CL K(Peer Clock)

ClrDelay

Clear SET Comman BTSTHEF BSC6900 d Delay TALM(Op Time tional)

Alarm CLRFLG Cleared Flag

EXP ALMLOG( Optional) BSC6900 STA ALMLOG( Optional)

Clear SET Comman BTSTHEF ClrInterval BSC6900 d Time TALM(Op Interval tional)

CMD

EXP Comman BSC6900 LOG(Opti d Name onal)

Delay for which the BTS waits to run the burglar alarm clearance command after reporting the burglar alarm Whether the alarm to be queried is cleared. You can select "cleared" or "uncleare d", or both of them. By default, both of them are selected. Interval at which the BTS runs the burglar alarm clearance command automatic ally Name of the command to be queried. You can select one or more command s.

GBFD111202

O&M of BTS

Interval Type

0~255

MRFD210304

Faulty Bit Field Managem Type ent

cleared, uncleared

GBFD111202

O&M of BTS

Interval Type

0~255

GBFD111203 MRFD210305

O&M of BSC String Security Type Managem ent

None

CMD

You can ADD select one Comman BSC6900 CCG(Man or more d Name datory) command s.

GBFD111203 MRFD210305

O&M of BSC String Security Type Managem ent

None

Sequence number of ADD the Comman SUBCMD command GBFDCMDSEQ d BSC6900 (Mandator string of 111203 Sequence y) the scheduled subtask. CN Cabinet No. ADD BSC6900 CAB(Man datory) ADD TRXBIND 2PHYBR D(Optiona l) SWP BTSRING (Optional) SWP BTSOML LINK(Opti onal) SET BTSFMU ABP(Opti onal) SET BSC6900 BTSAPM UBP(Opti onal) SET BTSDAT UBP(Opti onal) SET BTSDEM UBP(Opti onal) SET BTSDHE UBP(Opti onal) SET BTSUSC Number of the cabinet MRFD210301

O&M of BSC

Interval Type

0~19

Configura tion Interval Managem Type ent

1~3

CN

Cabinet No.

Number of the cabinet

GBFD111202

O&M of BTS

Interval Type

0~62

CN

Cabinet No.

ADD BTSBFD( Optional) Number BSC6900 ADD of the BTSIPRT cabinet BIND(Opti onal)

GBFD118609

IP Fault Detection Interval Based on Type BFD

0~62

CN

Port Cabinet No.

ADD BTSSFP MODE(O ptional) SET BTSFOR BIDTS(O ptional) SET BTSOML TS(Option al) SET BTSETH PORT(Op tional) ADD BSC6900 BTSPPPL NK(Optio nal) ADD BTSMPL NK(Optio nal) ADD BTSETH MA(Optio nal) ADD BTSETHL CMEP(Op tional) ADD BTSTOP

Number of the cabinet GBFDwhere the 111202 port is located

O&M of BTS

Interval Type

0~62

CN

Cabinet No.

LOD RETANT CFG(Opti onal) SET BTSANT ANGLE(O ptional) SET BTSCLKP ARA(Opti onal) SET BTSCAV FRQ(Opti onal) Number SET BSC6900 of the BTSPMU cabinet DEF(Opti onal) SET BTSTMA( Optional) SET RETANT ENB(Opti onal) STR BTSBATT TST(Opti onal) STR BTSTST( Mandator OPR Number BTSBRD BSC6900 of the PWR(Ma cabinet. ndatory)

GBFD111202

O&M of BTS

Interval Type

0~62

CN

Cabinet No.

GBFD111202

O&M of BTS

Interval Type

Time delay in the detection of core network interface failure. Within the preset value of this SET parameter CNFAUL CN Fault GBSCRE , the GBFDBSC6900 TDELAY Delay DGRP(Op BSC6900 113725 tional) continuou sly detects core network interface failures and then releases the managem ent right of service ADD GCNNOD BSC6900 E(Mandat ory) Used to uniquely GBFDidentify an 117401 MSC

BSC Node Interval Redunda Type ncy

1~60

CNID

MSC ID

MSC Pool

Interval Type

0~4095

CNID

SGSN Node ID

ADD NSE(Man datory) ADD SGSNNO BSC6900 DE(Mand atory) ADD NRISGSN MAP(Man datory)

Uniquely identifies a node of SGSN, GBFDwith the 119701 specified operator name

SGSN Pool

Interval Type

0~4095

ADD NRIMSC MAP(Man datory) SET MSGSOF TPARA(M andatory) SET CNNODE CN Node AITFOTH BSC6900 IDX Index PARA(Ma ndatory) SET BSCAITF TMR(Man datory) ADD GCNNOD E(Mandat ory)

Index of an MSC. It is used in storing GBFDand 117401 querying the MSC attributes

MSC Pool

Interval Type

0~31

CNOPER CMP Index of Operator ATORIND BSC6900 LICENSE the Index EX (Optional) operator

MRFD210403

License Interval Managem Type ent

0~3

Policy of the BSC6900 for judging whether the interface status of the core network is normal. If the value is NONE, the CNSTAT SET BSC6900 CN State EPOLICY GBSCRE does not GBFDPolicy For BSC6900 FORGRO DGRP(Op change 113725 Group UP tional) the service managem ent right. If the value is AINTFBL OCK, the BSC6900 releases the service managem ent right when detecting Number of returned alarm EXP records. Records MRFDBSC6900 ALMLOG( By to Return 210304 Optional) default, all records can be returned in each Type of the cabinet. The slot and SET subrack BTSBAT( arrangem GBFDBSC6900 Mandator ents in a 111202 y) cabinet vary according to the cabinet type.

NONE(No BSC ne), Node Enumerati AINTFBL Redunda on Type OCK(AInt ncy erf Block)

CNT

Faulty Interval Managem Type ent

1~150000

CNT

Cabinet Type

O&M of BTS

BTS3002 C, Enumerati BTS3012 on Type A, BTS3006 A

CNT

Cabinet Type

SET BTSDPM BSC6900 UBP(Man datory)

Type of the BTS cabinet GBFDwhere the 111202 DMPU is installed

O&M of BTS

CNTL

Counts Limit

Maximum number of SET records LOGLIMI BSC6900 allowed in T(Optiona the l) operation log

BTS3012( BTS3012) , BTS3012 AE(BTS3 012AE), BTS3006 C(BTS30 06C), BTS3012 _II(BTS30 12 II), BTS3002 E(BTS30 02E), DBS3900 Enumerati _GSM(DB on Type S3900 GSM), BTS3900 _GSM(BT S3900 GSM), BTS3900 A_GSM(B TS3900A GSM), DBS3036 (DBS303 6), BTS3036( BTS3036) , BTS3036

GBFD111203 MRFD210305

O&M of BSC Interval Security Type Managem ent

10000~50 000

Assume that this threshold is not 0. When the accumulat ed number of alarm blink times exceeds the threshold, the alarm Upper SET is count CNTRIST ALMBLKP reported. MRFDthreshold BSC6900 HRD ARA(Opti For 210304 of raised onal) querying fault the alarm blink measure ment period, see "LST ALMBLKS W". For setting the alarm blink measure ment period, see "SET

Faulty Interval Managem Type ent

0~250

Assume that this threshold is not 0. When the number of alarm blink times is smaller than the threshold, the alarm is reported. Lower SET For count CNTSTLT ALMBLKP querying MRFDthreshold BSC6900 HRD ARA(Opti the alarm 210304 of raised onal) blink fault measure ment period, see "LST ALMBLKS W". For setting the alarm blink measure ment period, see "SET ALMBLKS W". Whether to adjust the SET candidate COBSCM CoGCELLH cell queue SCADJE BSC/MSC BSC6900 OBASIC( to give N Adj Optional) priority to intraBSC/MSC handover

Faulty Interval Managem Type ent

0~250

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

CODE

Code

ADD GSMSCB BSC6900 (Mandator y)

Refrigerat SET COLDSE ion BTSOUT BSC6900 T Equipmen PUT(Opti t onal)

Number of a simple cell broadcast message. You can run "DSP GSMSCB " to query and obtain the informatio n. The value of this parameter cannot be 0. This parameter , "Geograp hy Scope", and "Update" uniquely decide a cell Whether to start the refrigerati on equipmen t of the BTS. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter

GBFD113602

Simplified Interval Cell Type Broadcast

1~1023

GBFD111202

O&M of BTS

INACTIV E(Inactive Enumerati ), on Type ACTIVE( Active)

COL COLTYP Collection SYNCINF BSC6900 E Type O(Mandat ory)

SET GCELLP COMBIN Combiner BSC6900 WRBASI ERLOSS Loss C(Optiona l)

Whether to collect offset informatio n by the BTS or cell Combined loss used to estimate the downlink power during assignme nt

GBFD118201

SoftBYSITE(B Synchroni Enumerati y Site), zed on Type BYCELL( Network By Cell)

GBFD117602

Active Power Control

Interval Type

0~100

Level of common access control, used for load control, Common SET allowing COMMAC Access GCELLC BSC6900 or C Control CBASIC( forbidding Class Optional) the access of some users of common access levels

GBFD111003 GBFD110301 GBFD110302

Radio Common Channel Managem Bit Field ent Type Location Updating IMSI Detach

L0_FORB ID, L1_FORB ID, L2_FORB ID, L3_FORB ID, L4_FORB ID, L5_FORB ID, L6_FORB ID, L7_FORB ID, L8_FORB ID, L9_FORB ID

SET Password Complexit Complica PWDPOL MRFDComplexit BSC6900 y of the cy ICY(Optio 210305 y password nal)

Security Bit Field Managem Type ent

LOWERC ASE, UPPERC ASE, DIGIT, SPECIAL CHARAC TER

BTS SET BTS Transfer BTSBWP GBFDCOMPRS BSC6900 compress Compres ARA(Opti 111202 rate. sion Rate onal)

O&M of BTS

Interval Type

1~100

COMSC

Co-MSC

ADD GEXT2G BSC6900 CELL(Opt ional)

ADD Connect CONBSC BTSABIS BSC BTS BTSIDTY BSC6900 HDLCPA Index PE TH(Mand Type atory)

Whether the BSC that controls the external cell and the local BSC belong to the same MSC Index type of the BTS connecte d the If to BSC

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

GBFD111202

O&M of BTS

BYNAME( By Enumerati Name), on Type BYID(By Index)

ADD Recover PORTFL CONGCL threshold BSC6900 OWCTRL RTHD0 of queue PARA(Op 0 [ms] tional)

ADD Recover PORTFL CONGCL threshold BSC6900 OWCTRL RTHD1 of queue PARA(Op 1 [ms] tional)

duration for buffering the data in queue 0 is less MRFDthan or 211503 equals to the value of this parameter , flow control is canceled. If the duration for buffering the data in queue 1 is less None than or equals to the value of this parameter , flow control is canceled.

2G/3G CoTransmis sion Resource Interval s Type Managem ent on MBSC

10~150

None

Interval Type

10~150

ADD Recover PORTFL CONGCL threshold BSC6900 OWCTRL RTHD2 of queue PARA(Op 2 [ms] tional)

ADD Recover PORTFL CONGCL threshold BSC6900 OWCTRL RTHD3 of queue PARA(Op 3 [ms] tional)

ADD Recover PORTFL CONGCL threshold BSC6900 OWCTRL RTHD4 of queue PARA(Op 4 [ms] tional)

ADD Recover PORTFL CONGCL threshold BSC6900 OWCTRL RTHD5 of queue PARA(Op 5 [ms] tional)

If the duration for buffering the data in queue 2 is less than or equals to the value of this parameter , flow control is canceled. If the duration for buffering the data in queue 3 is less than or equals to the value of this parameter , flow control is canceled. If the duration for buffering the data in queue 4 is less than or equals to the value of this parameter , flow control is canceled. If the duration for buffering the data in queue 5 is less than or equals to the value of this parameter , flow control is canceled.

None

None

Interval Type

10~150

None

None

Interval Type

10~150

None

None

Interval Type

10~150

MRFD211503

2G/3G CoTransmis sion Resource Interval s Type Managem ent on MBSC

10~150

Congestio ADD n PORTFL CONGTH threshold BSC6900 OWCTRL D0 of queue PARA(Op 0 [ms] tional)

Congestio ADD n PORTFL CONGTH threshold BSC6900 OWCTRL D1 of queue PARA(Op 1 [ms] tional)

Congestio ADD n PORTFL CONGTH threshold BSC6900 OWCTRL D2 of queue PARA(Op 2 [ms] tional)

Congestio ADD n PORTFL CONGTH threshold BSC6900 OWCTRL D3 of queue PARA(Op 3 [ms] tional)

If the duration for buffering the data in queue 0 is more than or equals to the value of this parameter , flow control is triggered. If the duration for buffering the data in queue 1 is more than or equals to the value of this parameter , flow control is triggered. If the duration for buffering the data in queue 2 is more than or equals to the value of this parameter , flow control is triggered. If the duration for buffering the data in queue 3 is more than or equals to or equals to the value of this parameter , flow control is

MRFD211503

2G/3G CoTransmis sion Resource Interval s Type Managem ent on MBSC

10~150

None

None

Interval Type

10~150

None

None

Interval Type

10~150

None

None

Interval Type

10~150

Congestio ADD n PORTFL CONGTH threshold BSC6900 OWCTRL D4 of queue PARA(Op 4 [ms] tional)

Congestio ADD n PORTFL CONGTH threshold BSC6900 OWCTRL D5 of queue PARA(Op 5 [ms] tional)

If the duration for buffering the data in queue 4 is more None than or equals to the value of this parameter , flow control is triggered. If the duration for buffering the data in queue 5 is more MRFDthan or 211503 equals to the value of this parameter , flow control is triggered.

None

Interval Type

10~150

2G/3G CoTransmis sion Resource Interval s Type Managem ent on MBSC

10~150

Concentri SET CONHOE c Circles GCELLH BSC6900 N HO OBASIC( Allowed Optional)

CONNEC Connect TPORTN Port No. O

ADD DXXCON BSC6900 NECT(Ma ndatory)

Whether to enable the concentric cell handover algorithm. The concentric cell handover helps to achieve wide coverage in the underlaid subcell and aggressiv e frequency reuse in the overlaid subcell and to improve the system capacity and conversati on quality. Number of the port through which the DXX is connecte d to the BSC6900

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

MRFD210206

Tree Interval Topology Type

0~335

CONNP WR

Whether Connect ADD to power SUBRAC connect MRFDBSC6900 monitorin K(Optiona the power 210301 g board l) monitorin g board

Configura NO(NO), tion Enumerati YES(YES Managem on Type ) ent

SET CONNTY Connectio CONNTY BSC6900 PE n Type PE(Mand atory)

ADD CONNTY Connectio GIURGC BSC6900 PE n Type ONN(Man datory)

Type of the connectio n between the NE and EMS or LMT. The connectio n can be a plain connectio n or SSL encryptio Whether the Iur-g common connectio n is establishe d between the BSC and a coBSC6900 RNC or an external

GBFD111203 MRFD210305

ALL(ALL O&M of Type), BSC ONLY_SS Enumerati Security L(Only on Type Managem SSL ent Connectio n)

MRFD211402

INNER(Int ernal MBSC Enumerati RNC), Load on Type EXTERN Balancing AL(Extern al RNC)

Minimum interval between the two consecuti ve handover decisions of an MS. The BSC cannot make a handover decision during the Min SET minimum Interval CONTHO GCELLH interval. for BSC6900 MININTV OCTRL(O To avoid Consecuti ptional) frequent ve HOs handover events in the cell, the BSC starts a timer after delivering a handover command to an MS. The BSC allows the MS to make a

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~60

The twice intra-cell handover events during Interval SET this for CONTINT GCELLH interval Consecuti BSC6900 V OAD(Opti are ve HO onal) considere Jud. d consecuti ve handover events.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~200

Whether to perform the PING operation continuou sly. When the continuou s PING operation is performe Continue PING d, the CONTPIN MRFDping or BSC6900 IP(Option system G 211503 not al) sends the PING packets to the specified IP address. You can stop the PING operation by using CTRL + PING MAC(Opti Transmitt Send PKT onal) MRFDBSC6900 ed Count PING 211503 packets BTSCFM( Optional) Duration STR for BTSTST( GBFDBSC6900 starting Mandator 111207 the CPRI y) Loop test

2G/3G CoTransmis sion NO(NO), Resource Enumerati YES(YES s on Type ) Managem ent on MBSC

Count

2G/3G CoTransmis sion Resource Interval Type s Managem ent on MBSC

1~28

CPRIDUR Duration ATS Second

BTS Test Interval Function Type

1~60

CPS

This parameter specifies whether to allow the Allow SET BSC6900 Dynamic GTRXDE GBFDBSC6900 to enable Shutdown V(Optiona 111602 or disable of TRX l) the power amplifier of a TRX based on the traffic volume.

TRX Power Enumerati NO(No), Amplifier on Type YES(Yes) Intelligent Shutdown

CPUN

CPU NO

ADD GCBSAD BSC6900 DR(Mand atory)

CPU number on a board

MRFD210301

Configura tion Interval Managem Type ent

0~7

CRC4 CRC4CH Check K Switch

SET BTSCRC BSC6900 4(Mandat ory)

Whether to enable the BTS GBFDto support 111202 CRC4 check

O&M of BTS

OFF(Off), ON(On), Enumerati NOTSUP on Type PORT(No t Support)

CRH

Cell reselectio n hysteresis . This is one of the parameter s used for deciding whether to reselect cells in different Cell location Reselect SET areas. Hysteresi GCELLID This BSC6900 s LEBASIC( parameter Paramete Optional) can avoid rs the increase of network signaling traffic due to frequent location update and reduce the risk of losing paging

GBFD110402 GBFD110301 GBFD110303

Basic Cell 0dB, 2dB, Re4dB, 6dB, selection Enumerati 8dB, Location on Type 10dB, Updating 12dB, Paging 14dB

CRL

Name of Certificate SET the Revocatio CERTFIL MRFDBSC6900 certificate n List File E(Mandat 210305 revocatio Name ory) n list file

Security String Managem Type ent

None

Certificate SET CRLEnabl Revocatio CERTFIL BSC6900 eSta n List File E(Optiona State l)

Channel CRMSGR Release ESENDIN Resend T Interval

SET GCELLG BSC6900 SMR(Opti onal)

Whether to enable the certificate revocatio n list DISABLE: indicating that the certificate revocatio n list is disabled ENABLE: indicating that the certificate revocatio n list is enabled Time interval for the BTS resending a channel release message

MRFD210305

DISABLE( Security Enumerati Disable), Managem on Type ENABLE( ent Enable)

GBFD510301 GBFD510302

Public Voice Group Call Interval Service Type Public Voice Broadcast Service Public Voice Group Call Interval Service Type Public Voice Broadcast Service

1~255

Channel CRMSGR Release ESENDN Resend UM Number

Number of times SET the BTS GCELLG BSC6900 resends a SMR(Opti channel onal) release message

GBFD510301 GBFD510302

1~255

CRO

Cell Reselect Offset

Cell Reselect Offset (CRO), indicating a correction of the C2. Proper setting of this parameter can reduce the SET number of GCELLID handover GBFDBSC6900 LEBASIC( times, 110402 Optional) helpful for assigning an MS to a better cell. In a special case that the PT is 31, the larger the CRO value is, the lower the possibility of

Basic Cell Interval ReType selection

0~63

Threshold of the time for crosstalk detection. Within the threshold, if the call flag continuou sly appearing in the code stream is Cross SET different Call CROCAL BSCBASI from the GBFDDetect BSC6900 TMTHRD C(Optiona one 111203 Time l) saved in a Threshold transcode r (TC) or a BTS, the TC or the BTS considers that a crosstalk occurs and sends a message to the BSC6900. Upon

O&M of BSC

Interval Type

1~255

The field indicates whether the crossconnect path is available. When the crosspath is available, a maximum of four IP paths Cross IP ADD exists. CROSSIP address SCTPLN The four BSC6900 FLAG available K(Optiona IP paths flag l) are the IP path between the first local IP address and the first peer IP address, the IP path between the first local IP address Output

GBFD118602 GBFD118622

UNAVAIL ABLE(UN A over IP AVAILAB Enumerati A IP over LE), on Type E1/T1 AVAILAB LE(AVAIL ABLE)

range of the suppleme ntary informatio CHR n SET Suppleme contained CSADDTI GCSCHR GBFDntary Info BSC6900 in the NFO CTRL(Opt 111203 Output CHR in ional) Control common user mode. Multiple options can be selected

O&M of BSC

Bit Field Type

VOICEIN F, MR, CALLAPP ENDINF, CALLINN ERINF

Rate threshold Bad SET of bad Speech CSBQTH GCSCHR speech GBFDQuality BSC6900 R CTRL(Opt quality in 111203 Rate ional) common Threshold user mode.

O&M of BSC

Interval Type

0~100

Whether MR is SET contained CSCHRM CHR MR GCSCHR in the GBFDBSC6900 R Output CTRL(Opt CHRs in 111203 ional) specified user mode Whether the informatio n about the Abnormal SET CSCLTE specified Call End GCSCHR GBFDRMABNO BSC6900 abnormal Output CTRL(Opt 111203 RM call end is Control ional) contained in the CHRs in common user

O&M of BSC

OFF(Not Enumerati Output), on Type ON(Outpu t)

O&M of BSC

Bit Field Type

RESINSU FF, UMABNO RM, TRAFFR EJECT, MSCREL, MSCDIS CON, BADQUA LITY

GSM CS data CSDATA service DL downlink factor

GSM CS ADD data TRMFAC BSC6900 service TOR(Opti downlink onal) factor

GBFD118605

IP QOS

Interval Type

0~100

CSDATA CS data PATH path

ADD CS data BSC6900 TRMMAP path (Optional)

GBFD118605

IP QOS

BE, AF11, AF12, AF13, AF21, AF22, Enumerati AF23, on Type AF31, AF32, AF33, AF41, AF42, AF43, EF

CSDATA CS data PRI priority

ADD CS data BSC6900 TRMMAP priority (Optional)

GBFD118605

IP QOS

Interval Type

0~7

GSM CS data CSDATA service UL uplink factor

GSM CS ADD data TRMFAC BSC6900 service TOR(Opti uplink onal) factor

GBFD118605

IP QOS

Interval Type

0~100

CSDSP

CS Data Service PRI

Priority of the CS data service. The parameter is used for ADD BSC6900 GBFDBSC6900 GCELL(O flow 111705 ptional) control. The smaller the value of this parameter , the higher the priority.

GSM Flow Control

Interval Type

0~7

Whether handover informatio CHR SET n is CSHOINF Handover GCSCHR contained GBFDBSC6900 O Informatio CTRL(Opt in the 111203 n Output ional) CHRs in common user mode Whether the MR before call SET release is GCSCHR GBFDBSC6900 contained CTRL(Opt 111203 in the ional) CHRs in common user mode.

O&M of BSC

OFF(Not Enumerati Output), on Type ON(Outpu t)

Output MR CSMRBF Before CLR Call Release

O&M of BSC

OFF(Not Enumerati Output), on Type ON(Outpu t)

Whether the MR before handover Output SET is CSMRBF MR GCSCHR GBFDBSC6900 contained HO Before CTRL(Opt 111203 in the Handover ional) CHRs in common user mode. CHR output mode. In common user mode, the CHRs of all the MSs specified by "CHR Output Range" are output. In SET specified GCSCHR user GBFDBSC6900 CTRL(Opt mode, the 111203 ional) CHR of a specific MS, which is specified by running the ADD GCSCHR USER command , is output. These two modes

O&M of BSC

OFF(Not Output), MRHOFA IL(Prefere ntially Output MR of HO Enumerati Failure), on Type MRHOLA TEST(Pre ferentially Output MR of Latest HO)

CHR CSOUTM Output ODE Mode

O&M of BSC

COMMO NUSRM( Common User Enumerati Mode), on Type SPECUS RM(Speci fied User Mode)

CHR CSOUTR Output ANGE Range

Area in which CHRs need to be output in common user mode. If this parameter SET is set to GCSCHR "Output GBFDBSC6900 CTRL(Opt All 111203 ional) Records "in Cells, you need to run the SET GCSCHR SCOPE command to specify the cells whose CHRs are SET GCSCHR BSC6900 CTRL(Ma ndatory) Whether to output the call history record (CHR)

O&M of BSC

ABNORM REC(Out put Abnormal Records in BSC), ALLBSCR Enumerati EC(Outpu on Type t All Records in BSC), ALLCELL REC(Out put All Records in Cells)

CHR CSRCDS Function W Switch

GBFD111203

O&M of BSC

Enumerati OFF(OFF on Type ), ON(ON)

SET CHR CSSIGIN GCSCHR Signaling BSC6900 FO CTRL(Opt Output ional)

Type of signaling GBFDcontained 111203 in CHRs

O&M of BSC

OFF(Not Output), ALL(Outp ut All), AINTF(Ou tput A Enumerati Interface on Type Signaling) , ABISINTF (Output Abis Interface Signaling)

Congestio SET CSTART n Start BSC6900 GTRXFC( THD Threshold Optional)

Service CSTRAF Type of TYPE CHR Output

SET GCSCHR BSC6900 CTRL(Opt ional)

Threshold for starting LAPD link congestio n control. This parameter cannot be set too high. If this parameter is set too high, the signaling link may be congeste d before congestio n control is started. The congestio n start and end threshold s cannot be set too low. If they are set too low, Type of the service whose CHR need to be output

GBFD111705

GSM Flow Control

Interval Type

30~100

GBFD111203

O&M of BSC

Bit Field Type

LU, SMS, CALL

GSM CS voice CSVOICE service DL downlink factor

GSM CS ADD voice TRMFAC BSC6900 service TOR(Opti downlink onal) factor

GBFD118605

IP QOS

Interval Type

0~100

Whether speech informatio CHR SET n is CSVOICE Speech GCSCHR contained GBFDBSC6900 INFO Informatio CTRL(Opt in the 111203 n ional) CHRs in specified user mode.

O&M of BSC

OFF(Not Enumerati Output), on Type ON(Outpu t)

ADD CSVOICE CS voice CS voice GBFDBSC6900 TRMMAP PATH path path 118605 (Optional)

IP QOS

BE, AF11, AF12, AF13, AF21, AF22, Enumerati AF23, on Type AF31, AF32, AF33, AF41, AF42, AF43, EF

ADD CSVOICE CS voice CS voice GBFDBSC6900 TRMMAP PRI priority priority 118605 (Optional)

IP QOS

Interval Type

0~7

GSM CS voice CSVOICE service UL uplink factor

GSM CS ADD voice TRMFAC BSC6900 service TOR(Opti uplink onal) factor

GBFD118605

IP QOS

Interval Type

0~100

CSVSP

Priority of a speech service in the CS domain. The parameter is used for CS Voice ADD BSC6900 GBFDService BSC6900 GCELL(O flow 111705 PRI ptional) control. The smaller the value of this parameter , the higher the priority.

GSM Flow Control

Interval Type

0~7

CSW

CT1

SelfSelfhealing healing switch for Switch for SET the Ethernet SLFSLVS BSC6900 Ethernet None Adapter W(Option adapter Traffic al) traffic Monitorin monitorin g g Timer alignment ready. Timer T1 is started after the MTP2 link enters the Aligned Ready state. If one end of the MTP2 link receives ADD an FISU Timer MTP3LN or MSU GBFDalignment BSC6900 K(Optiona message 111804 ready l) from the peer end within the period of time defined by T1, the MTP2 link enters the In-service state. In other cases, T1 expires, and the MTP2 link

None

ON(ON), Enumerati OFF(OFF on Type )

A Interface Protocol Process

Interval Type

40000~50 000

CT2

Timer not aligned. Timer T2 is started at the time that the MTP2 link is set up and begins to transmit the SIO message. If one end of the ADD MTP2 link Timer not MTP3LN receives GBFDBSC6900 aligned K(Optiona an SIO, 111804 l) SIN, or SIE message from the peer end with the period of time defined by T2, the MTP2 link enters the next state. In other cases, T2 expires,

A Interface Protocol Process

Interval Type

5000~150 000

CT3

Timer aligned

Timer aligned. Timer T3 is started at the time that the MTP2 link enters the aligned state and starts to transmit SIN (normal ADD alignment MTP3LN ) or SIE GBFDBSC6900 K(Optiona (emergen 111804 l) cy alignment ) message. If one end of the MTP2 link receives an SIN or SIE message from the peer end with the period of time

A Interface Protocol Process

Interval Type

1000~200 0

CT4E

Timer emergenc y proving. The two ends of the MTP2 link exchange message s after entering the emergenc y verificatio ADD n state. Timer MTP3LN Each end GBFDemergenc BSC6900 K(Optiona verifies 111804 y proving l) the correctne ss of the message s sent from the peer end. If the error rate of the message s reaches the threshold specified by the

A Interface Protocol Process

Interval Type

400~600

CT4N

Timer normal proving

Timer normal proving. The two ends of the MTP2 link exchange message s after entering the normal verificatio n state. ADD Each end MTP3LN verifies GBFDBSC6900 K(Optiona the 111804 l) correctne ss of the message s sent from the peer end. If the error rate of the message s reaches the threshold specified by the protocol,

A Interface Protocol Process

Interval Type

7500~950 0

CT5

Timer sending SIB

Timer sending SIB. If one end of the MTP2 link detects congestio n, it sends SIB indication s to the peer end ADD at an MTP3LN interval GBFDBSC6900 K(Optiona specified 111804 l) by timer T5. This parameter only applies to the 64 kbit/s links. For the 2 Mbit/s links, the value of this timer is always

A Interface Protocol Process

Interval Type

80~120

CT6

Timer remote congestio n. A link is considere d broken when the remote congestio n duration exceeds the value Timer ADD specified remote MTP3LN by timer GBFDBSC6900 congestio K(Optiona T6. This 111804 n l) parameter only applies to the 64 kbit/s links. For the 2 Mbit/s links, the value of this timer is always 5000.

A Interface Protocol Process

Interval Type

3000~600 0

CT7

Timer excessive delay acknowle dgement. A link is considere d broken if one end of the link does not receive a verificatio n message Timer ADD from the excessive MTP3LN peer end GBFDdelay of BSC6900 K(Optiona within the 111804 acknowle l) period of dgement time defined by timer T7 after sending a message. This parameter only applies to the 64 kbit/s links. For the 2 Mbit/s

A Interface Protocol Process

Interval Type

500~2000

CT9

Timer interval of resending FISU. Timer T9 specifies the interval at which the BSC sends the FISU frames. That is, the BSC Timer ADD sends an interval of MTP3LN FISU GBFDBSC6900 resending K(Optiona frame 111804 FISU l) every N (N indicates the period of time defined by T9) when the MTP2 link is idle. This parameter only applies to the 64 kbit/s

A Interface Protocol Process

Interval Type

1~100

CTHD

SET Critical FCCPUT BSC6900 threshold HD(Optio nal)

CTHD

SET Critical FCMSGQ BSC6900 threshold THD(Opti onal)

Critical threshold of CPU usage. When the CPU usage in "Fast judgemen t window" reaches or exceeds the threshold, all active flow control functions are implemen ted. Otherwise , the correspon ding flow control mechanis Critical threshold of packet queue usage. When the packet queue usage reaches or exceeds the threshold, all active flow control functions are implemen DPC of the control BSC

GBFD111705

GSM Flow Control

Interval Type

30~100

GBFD111705

GSM Flow Control

Interval Type

30~100

ADD CTRBSC Control AISSCFG BSC6900 DPC BSC DPC (Mandator y)

GBFD118201

SoftSynchroni Interval zed Type Network

1~167772 15

Format of the control acknowle dge message of the MS. Four access bursts are used to obtain timing SET Control advance CTRLAC GCELLP GBFDAcknowle BSC6900 without KTYPE SBASE(O 114101 dge Type sending ptional) polling message; RLC/MAC control block is used to obtain timing advance after sending polling message. SET BTSLOA Control BSC6900 DCTRL(M Flag andatory)

GPRS

4BURST( 4Burst), Enumerati RLC/MAC on Type (RLC/MA C)

CTRLFLA Control G Flag

GBFD111202

O&M of BTS

NO(Canc el Control Enumerati Flag), on Type YES(Set Control Flag)

Control CTRLPO Port RTCN Cabinet No.

Number of the ADD cabinet BTSRET BSC6900 which ANT(Man controls datory) RET antenna.

MRFD210602

Remote Interval Electrical Type Tilt

0~62

CTRLPO Control RTNO Port No.

Control CTRLPO Port Slot RTSN No.

Control CTRLPO Port RTSRN Subrack No.

ControlPo rt No. of RET antenna. The number of RET antenna which connect to same ADD feed BTSRET tributary MRFDBSC6900 ANT(Man cannot be 210602 datory) more than 6.For GATM boards, the valid value ranges from 0 to 5. For RXU boards, the valid Number of the slot where the board controlling the RET antenna is located. For ADD SingleRA BTSRET N BTSs, MRFDBSC6900 ANT(Man the valid 210602 datory) value ranges from 0 to 5. For nonSingleRA N BTSs, the valid value ranges from 0 to Number of the ADD subrack BTSRET MRFDBSC6900 where the ANT(Man 210602 BTS datory) board is located

Remote Interval Electrical Type Tilt

0~5

Remote Interval Electrical Type Tilt

0~23

Remote Interval Electrical Type Tilt

0~254

CTRLSL OT

Slot No.

ADD RSCGRP BSC6900 (Mandator y)

SET Control BTSCTRL CTRLSN Plane Slot BSC6900 (Mandator No. y)

Control CTRLSR Plane N Subrack No.

SET BTSCTRL BSC6900 (Mandator y)

Slot number of the MPU Subsyste m for the centralize d managem ent of the resources Number of the BSC6900 slot where the XPU of the control plane is located Number of the BSC6900 subrack where the XPU of the control plane is located Configura

GBFD118605

IP QOS

Interval Type

0,2,4,8,10 ,12,14,16, 18,20,22, 24,26

GBFD111202

O&M of BTS

Interval Type

0~27,255

GBFD111202

O&M of BTS

Interval Type

0~11,255

CM Control CTRLSW Enable Switch

tion rollback control SET switch CMCTRL that is MRFDBSC6900 SW(Mand used to 210301 atory) specify whether to support the configurat

Configura ON(ON), tion Enumerati OFF(OFF Managem on Type ) ent

Whether an SET HO_RQD CurChann HO_RQD MSGSOF message GBFDelInHoRq Current BSC6900 TPARA(O contains 111804 d Channel ptional) the Current Channel

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

CVer

SET BTSAUT C-Version BSC6900 ODLDAC No. TINFO(M andatory)

C-version number of GBFDthe BTS 111202 software

O&M of BTS

Interval Type

0~99

Period of Period of SET New File new file CYCLE BSC6900 GCSFILE Generatio generatio (Optional) n[min] n. This is the data file for UPD upgrading DATAFIL JTGCPLD board. Data file BSC6900 E (Mandator The data y) file names of different boards Number of measure ment reports sampled for averaging the signal quality on a speech/d ata channel. Averaging SET Filter the signal DATAQU GCELLH Length for BSC6900 quality in AFLTLEN OFITPEN TCH Qual multiple (Optional) measure ment reports helps to avoid a sharp signal quality drop due to Rayleigh fading and to ensure the

None

None

Interval Type

10~255

MRFD210401

BSC/RNC Software String Managem Type ent

None

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~31

Filter SET DATAST Length for GCELLH BSC6900 RFLTLEN TCH OFITPEN Level (Optional)

Data DATATR Service AFFSET Allowed

SET GCELLO BSC6900 THEXT(O ptional)

Number of measure ment reports sampled for averaging the signal strength on a speech/d ata channel. Averaging the signal strength in multiple measure ment reports helps to avoid a sharp signal level drop due to Rayleigh fading and to ensure Data service supported by the BSC6900. You can set this parameter according to actual requireme nts.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~31

GBFD110204 GBFD119405 GBFD110205

G3 Fax (TS61, TS62) 14.4kbit/s Bit Field Circuit Type Switched Data Bearer Service

NT14_5K ~0 NT12K~1 NT6K~2 T14_4K~ 3 T9_6K~4 T4_8K~5 T2_4K~6 T1_2K~7 T600_BIT S~8 T1200_75

DATE

Whether to limit the ADD operation Date Limit BSC6900 OP(Optio date of nal) the operator

GBFD111203 MRFD210305

O&M of NOLIMIT( BSC Enumerati No Limit), Security on Type LIMIT(Lim Managem it) ent

DATE

Date

SET BSC6900 TIME(Opti Date onal)

GBFD111203

O&M of BSC

YEAR, Compoun MONTH, d Type DAY

Prohib ADD DynShutd BSCDST DateRang own TRX BSC6900 PADATE( eIndex DateRang Mandator eIdx y)

Day

Day

SET BTSAUT BSC6900 ODLDAC TINFO(M andatory)

DBD

Dead Band

SET BTSDHE BSC6900 UBP(Opti onal)

Unique number of the date range during which to disable the BSC from shutting down the TRX dynamical ly Date when the TMU board software is released Temperat ure error allowed when the temperatu re control system adjusts the temperatu re. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another

GBFD111602

TRX Power Interval Amplifier Type Intelligent Shutdown

1~12

GBFD111202

O&M of BTS

Interval Type

0~31

GBFD111202

O&M of BTS

Interval Type

0~30

Whether the primary BCCH is BCCH configure DBFREQ IUO of ADD d on the GBFDBCCHIU Double BSC6900 GCELL(M inner or 114501 O Frequenc andatory) extra part y Cell of an intelligent underlayoverlay (IUO) cell

Inner(Inne Co-BCCH Enumerati r), Cell on Type Extra(Extr a)

Index of a same Same ADD group cell DBLFRE GBFDGroup BSC6900 GCELL(M in an QADJCID 114402 Cell Index andatory) enhanced dual band network Same DBLFRE Group QADJCN Cell AME Name Name of a same ADD group cell GBFDBSC6900 GCELL(M in an 114402 andatory) enhanced dual band network

Enhanced DualInterval Band Type Network

0~2047

Enhanced DualString Band Type Network

None

Index type of a same Same DBLFRE ADD group cell Group GBFDQADJIDT BSC6900 GCELL(M in an Cell Index 114402 YPE andatory) enhanced Type dual band network

BYNAME( Enhanced By DualEnumerati Name), Band on Type BYID(By Network Index)

DC Low Voltage DCLACN Alarm Cabinet No.

DC SET Lowvoltag BTSALM GBFDBSC6900 e Alarm PORT(Ma 111202 Cabinet ndatory) No.

O&M of BTS

Interval Type

0~255

DC Low Voltage DCLAPN Alarm Port No.

SET BTSALM BSC6900 PORT(Ma ndatory)

DC Lowvoltag GBFDe Alarm 111202 Port No.

O&M of BTS

Interval Type

0~255

DC Low Voltage DCLASN Alarm Slot No.

SET BTSALM BSC6900 PORT(Ma ndatory)

DC Lowvoltag GBFDe Alarm 111202 Slot No.

O&M of BTS

Interval Type

0~255

DC Low Voltage DCLASR Alarm N Subrack No.

DC SET Lowvoltag BTSALM GBFDBSC6900 e Alarm PORT(Ma 111202 Subrack ndatory) No.

O&M of BTS

Interval Type

0~255

DC voltage alarm lower threshold. When the busbar output voltage is lower than the value of this parameter , an alarm DC SET indicating DCVLTH Voltage BTSAPM the GBFDBSC6900 D Lower UBP(Opti abnormal 111202 Threshold onal) busbar voltage is reported. In multimode scenario, the value of this parameter in one mode must be the same as the value of the

O&M of BTS

Interval Type

350~556

DC SET DCVOLA Overvolta BTSDPM BSC6900 LARMH ge Alarm UBP(Opti Threshold onal)

DC Under SET DCVOLA Voltage BTSDPM BSC6900 LARML Alarm UBP(Opti Threshold onal)

The BTS reports an alarm if the DC voltage exceeds the value of this parameter . In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter The BTS reports an alarm if the DC voltage is lower than the value of this parameter . In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter

MRFD210304

Faulty Interval Managem Type ent

580~600

MRFD210304

Faulty Interval Managem Type ent

433~555

DC voltage alarm upper threshold. When the busbar output voltage is higher than the value of this parameter , an alarm DC SET indicating DCVUTH Voltage BTSAPM the GBFDBSC6900 D Upper UBP(Opti abnormal 111202 Threshold onal) busbar voltage is reported. In multimode scenario, the value of this parameter in one mode must be the same as the value of the

O&M of BTS

Interval Type

580~600

This parameter specifies the default preconverted PDCHs in the dynamic transferab le channel pool. When this Number parameter of SET is greater DefaultDy Dynamic GCELLP than 0, GBFDnPdchPre Channel BSC6900 SCHM(O three sub- 113101 TranNum Preptional) links are Converte bound to d the static PDCH and preconverted PDCH in a cell by default. The preconverted PDCH can be preempte d. You can set

PDCH Dynamic Interval Adjustme Type nt

0~32

DELAYSE NDRFCH T3111 REL

SET GCELLT BSC6900 MR(Optio nal)

DENO

ADD M3DE(Ma ndatory) Destinatio ADD n entity BSC6900 M3RT(Ma No. ndatory) ADD M3LKS(M andatory)

Timer for delaying a connectio n release. This parameter is used for delaying the channel deactivati on after the active signaling link is broken. The purpose is to reserve some time for the disconnec tion that may be repeated. After receiving a REL IND message sent by The destinatio n entity number uniquely identifies a destinatio n entity.

GBFD110501

Call Control

Interval Type

500~6000 0

GBFD118602 GBFD118622

A over IP Interval A IP over Type E1/T1

0~186

DESC

Descriptio ADD Descriptio n of the BSC6900 OP(Optio n operator nal) account

GBFD111203 MRFD210305

O&M of BSC String Security Type Managem ent

None

Whether to start the antitheft equipmen t of the BTS. In multimode scenario, SET Anti-theft the value DESTEAL BTSOUT GBFDEquipmen BSC6900 of this SET PUT(Opti 111202 t parameter onal) in one mode must be the same as the value of the correspon ding parameter

O&M of BTS

INACTIV E(Inactive Enumerati ), on Type ACTIVE( Active)

DESTIP

Destinatio PING Destinatio n IP BSC6900 IP(Manda n IP None address tory) address

None

IP Address Type

None

DESTIP

DESTIP

TRC Destinatio Destinatio IPADDR( n IP BSC6900 n IP None Mandator address address y) ADD Destinatio Destinatio IPRTBIN n IP BSC6900 n IP None D(Mandat address address ory)

None

IP Address Type IP Address Type

None

None

None

PING MAC(Man datory) TRC MAC(Man datory) DESTME RMEP ID BSC6900 PING PID BTSCFM( Mandator y) TRC BTSCFM( Mandator ADD DESTNO Transport BTSAUT BSC6900 DE Link Type OPLAN(M andatory)

Identifies a maintena nce point None in the maintena nce group

None

Interval Type

1~1000

Type of the object the BTS GBFDis 510701 connecte d to

Compact BTS Automatic Enumerati BSC, BTS Configura on Type tion and Planning

Dest DESTNO Node DE Type

Type of the object the BTS ADD is BTSCON connecte GBFDBSC6900 NECT(Ma d to. 111202 ndatory) Value range: BTS, BSC6900, Slot No.

O&M of BTS

BTS, Enumerati BSC, on Type DXX, OTHER

of the subsyste m where the Iur-g ADD common Peer Slot GIURGC MRFDDESTSN BSC6900 connectio No. ONN(Man 211402 n is datory) establishe d to the coBSC6900 RNC Subrack No. of the subsyste m where the Iur-g ADD common GIURGC MRFDBSC6900 connectio ONN(Man 211402 n is datory) establishe d to the coBSC6900 RNC

MBSC Interval Load Type Balancing

0~27

Peer DESTSR Subrack N No.

MBSC Interval Load Type Balancing

0~11

ADD Peer DESTSS GIURGC Subsyste BSC6900 N ONN(Man m No. datory)

Destinatio MOV DESTTR n Main BSC6900 BCCH(Ma XID BCCH ndatory) TRX ID

Period of Mute SET DETECT Detect GCELLS FRAMEP BSC6900 Class2 OFT(Opti ERIOD TRAU onal) Frame

No. of the subsyste m where the Iur-g common connectio n is establishe d to the coBSC6900 RNC ID of the TRX that carries the destinatio n main BCCH Interval for sending test TRAU frames in the period of class-2 mute detection. Test TRAU frame is sent at the specified interval till the peer end responds or the timer of "Period of Mute

MRFD211402

MBSC Interval Load Type Balancing

0~7

MRFD210301

Configura tion Interval Managem Type ent

0~3071

GBFD111203

O&M of BSC

Interval Type

0~255

DETECT Detect MULT Period

Maximum number of periods in which the local end does not receive BFD packets from the peer end. If the number of periods in ADD which the GBFDBSC6900 BTSBFD( local end 118609 Optional) does not receive BFD packets from the peer end reaches this parameter , the BTS reports a BFD session fail.

IP Fault Detection Interval Based on Type BFD

3~10

Switch for SET Switch for DETECT Abis BTSABIS Abis GBFDBSC6900 SWITCH Timeslot TROP(Ma Timeslot 111202 Detection ndatory) Detection

O&M of BTS

Enumerati OFF(OFF on Type ), ON(ON)

DEVICEN Device AME Name

ADD Name of BTSRET BSC6900 the RET ANT(Man antenna datory)

MRFD210602

Remote String Electrical Type Tilt

None

DEVICEN Device O No.

DEVIP

ADD BTSRET BSC6900 ANT(Man datory) ADD PPPLNK( Mandator Borrowed y) device IP BSC6900 ADD address MPGRP( Mandator y)

Number of the MRFDRET 210602 antenna. Device IP address of the interface None board used by the PPP link.

Remote Interval Electrical Type Tilt

0~35

None

IP Address Type

None

Device IP ADD Device IP DEVTYP Address BSC6900 DEVIP(M Address None E Type andatory) Type ADD GEXT3G CELL(Ma ndatory) SET GCELLH DL BSC6900 OFDDBA UARFCN 2(Mandat ory) SET GCELLH OTDDBA 2(Mandat

None

LOGIC_I Enumerati P(Logical on Type IP Address)

DF

Downlink frequency of the external 3G cell

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~16383

Number SET of the slot DFCB BTSDFC GBFDDFCBSN BSC6900 where the Board SN UBP(Opti 111202 DFCB is onal) installed Number of the subrack GBFDwhere the 111202 DFCB is installed

O&M of BTS

Interval Type

0~23

DFCB DFCBSR Board N SRN

SET BTSDFC BSC6900 UBP(Opti onal)

O&M of BTS

Interval Type

0~254

DFDPC

Default DPC

The default DPC correspon ds to the CN of the primary operator. When only one DPC is configure d, this parameter must be ADD set to GCNNOD "YES", GBFDBSC6900 E(Optiona indicating 117401 l) that all the calls for the operator are accessed through the CN identified by the DPC. When multiple DPCs are configure d, this

NO(Not Default Enumerati MSC Pool DPC), on Type YES(Defa ult DPC)

Whether to use the customize d port DEFAULT PORT: indicating that the FTP server uses the default port 21 as The Type a SET of FTP command DFTPOR FTPSSR Server BSC6900 port and TSWT V(Mandat Comman port 20 as ory) d Port a data port to provide FTP services CUSTOM PORT: indicating that the FTP server uses the customize d port to DGPS data ADD DGPSPE report BSC6900 GPS(Opti RIOD period[mi onal) n]

GBFD111203 MRFD210305

DEFAULT PORT(De O&M of fault 21 BSC Enumerati Port), Security on Type CUSTOM Managem PORT(Cu ent stom Port)

Period for reporting MRFDdifferentia 210502 l GPS data

BSC/RNC Interval Clock Type

1~60

DHCP DHCPRL Relay YGATEW Gateway AYIP IP Address

DHCPRL DHCP YID Relay ID

This parameter ADD indicates DHCPRL the IP BSC6900 Y(Mandat Address ory) of DHCP Relay Gateway. ADD DHCPRL DHCP BSC6900 Y(Mandat Relay ID ory) SET BTSDPM BSC6900 UBP(Opti onal)

GBFD118611 GBFD118622

Abis IP over IP E1/T1 Address A IP over Type E1/T1

None

None

None

Interval Type

0~63

DIESELE NGINESA VESWIT CH

Diesel Engine Save Switch

Whether to enable the diesel GBFDengine 111202 save switch

O&M of BTS

DISABLE( DISABLE) Enumerati , on Type ENABLE( ENABLE)

Different DIFFBAN Band DSDCCH SDCCH USINGO Using PTIMIZE Optimize

Whether to allow an MS to report the classmark and whether to hand over the MS from the SET SDCCH GCELLC in the BSC6900 HMGBASI frequency C(Optiona band for l) the main BCCH to the SDCCH in a different frequency band according to the classmark

GBFD110608 GBFD111005

SDCCH Handover Enhanced Enumerati NO(No), Channel on Type YES(Yes) Assignme nt Algorithm

DINM

Date in Month

ADD SUBTSK( BSC6900 Mandator y)

Day in the month on which the GBFDcommand 111203 can be executed.

O&M of BSC

DINW

Date in Week

ADD SUBTSK( BSC6900 Mandator y)

Day in the week on which the GBFDcommand 111203 can be executed.

O&M of BSC

MON_1(N o.1), MON_2(N o.2), MON_3(N o.3), MON_4(N o.4), MON_5(N o.5), MON_6(N o.6), MON_7(N o.7), MON_8(N o.8), Enumerati MON_9(N on Type o.9), MON_10( No.10), MON_11( No.11), MON_12( No.12), MON_13( No.13), MON_14( No.14), MON_15( No.15), MON_16( No.16), MON_17( No.17), SUN(Sun day), MON(Mo nday), TUE(Tues day), Enumerati WED(We on Type dnesday), THU(Thur sday), FRI(Frida y), SAT(Satu rday)

DIR

DLD LICENSE (Mandator y) Directory BSC6900 ULD LICENSE (Mandator y)

The relative path in the working path of the FTP user in

GBFD111203 MRFD210403

O&M of BSC String License Type Managem ent

None

DIR

DLD RETANT CFG(Opti onal) DLD BTSPAT File CH(Optio BSC6900 Directory nal) ULD BTSLOG( Optional) DLD BTSSW( Optional)

Directory of the software GBFDto be 111202 download ed

O&M of BTS

String Type

None

Directed DirectedR Retry etryAssFa AssFail ilSendEna Send ble Enable

Whether the BSC sends an Assignme nt Fail message with the SET cause AITFOTH value of GBFDBSC6900 PARA(Op directed 110607 tional) retry to the MSC before the BSC initiates a directed retry procedure

Direct Retry

Enumerati NO(No), on Type YES(Yes)

DIRECTR Directed YEN Retry

Whether to enable a directed retry. The directed retry is to hand over an MS to a neighbori ng cell in the same procedure as the handover. SET The GCELLB directed GBFDBSC6900 ASICPAR retry is an 110607 A(Optiona emergenc l) y measure applicable to abnormal traffic peaks in some areas of a radio network. You should not use the

Direct Retry

Enumerati NO(No), on Type YES(Yes)

Whether a cell is a repeater. With simpler functions than a BTS, a repeater is a coverage extension device of a BTS. It is applied SET to widelyDIRMAG Directly GCELLS stretched GBFDANSITEF Magnifier BSC6900 OFT(Opti areas or 110601 LAG BTS Flag onal) indoor areas to solve the dead zone problem of BTS coverage. Using repeaters cannot increase the traffic capacity of a network

HUAWEI Enumerati NO(No), I on Type YES(Yes) Handover

Timer to control the duration in which the BSC prevents the handover of an MS from which the BSC receives the Disconne Disconne SET Disconne ct ctHandov OTHSOF ct Handover BSC6900 erProtect TPARA(O message. Protect Timer ptional) If the MS Timer is handed over to a new cell after the MS sends the Disconne ct message, the MS cannot receive the Release Acknowle ADD GEXT3G CELL(Ma Whether ndatory) to activate transmit SET GCELLH diversity DIVERSI Diversity BSC6900 OFDDBA on the TY 2(Mandat common channel ory) of a 3G SET GCELLH cell OTDDBA 2(Mandat

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~15

GBFD114301

GSM/WC DMA Enumerati NO(No), Interopera on Type YES(Yes) bility

Delay of transmit diversity when 16QAM is used. Generally, the parameter is applicable to general fading environm ents. The SET Diversity transmit DIVERT1 GCELLB Transmitt diversity GBFD6QAMDE BSC6900 ASICPAR er 16QAM 510804 can LAY A(Optiona Delay generally l) bring a gain of 3 dB to 5 dB. The fading conditions vary with the MS location; therefore, MSs in a fixed time delay obtain different

Downlink Interval EGPRS2Type A

4~32

Delay of transmit diversity when 32QAM is used. Generally, the parameter is applicable to general fading environm ents. The SET Diversity transmit DIVERT3 GCELLB Transmitt diversity GBFD2QAMDE BSC6900 ASICPAR er 32QAM 510804 can LAY A(Optiona Delay generally l) bring a gain of 3 dB to 5 dB. The fading conditions vary with the MS location; therefore, MSs in a fixed time delay obtain different

Downlink Interval EGPRS2Type A

4~32

SET Diversity DIVERT8 GCELLB Transmitt PSKDEL BSC6900 ASICPAR er 8PSK AY A(Optiona Delay l)

SET Four BTSRXU DivSwitch Diversity BSC6900 BP(Optio Receiver nal)

SET DLADJPR PwrCtrlDL GCELLP BSC6900 D AdjPeriod WR3(Opti onal)

Delay of transmit diversity when 8PSK is used. Generally, the parameter is applicable to general fading environm ents. The transmit diversity can generally bring a gain of 3 dB to 5 dB. The fading conditions vary with the MS location; therefore, MSs in a fixed time delay obtain different Whether to support transmitti ng diversity or four diversity receiving Minimum interval between two consecuti ve downlink power control command s

GBFD114201

EGPRS

Interval Type

4~32

GBFD115902

Transmit Diversity

Enumerati N0(No), on Type YES(Yes)

GBFD117601

HUAWEI III Power Interval Control Type Algorithm

0~255

If the downlink receive quality level of an AMR full rate call is DLAFSR SET greater DLAFSRe EXQUAL GCELLP than this GBFDxQualHig BSC6900 HIGHTHR WR3(Opti parameter 117601 hThred ED onal) , the call needs to undergo Huawei power control generatio n III.

HUAWEI III Power Interval Control Type Algorithm

1~30

If the downlink receive quality level of an AMR full rate call is DLAFSR SET smaller DLAFSRe EXQUAL GCELLP than this GBFDxQualLow BSC6900 LOWTHR WR3(Opti parameter 117601 Thred ED onal) , the call needs to undergo Huawei power control generatio n III.

HUAWEI III Power Interval Control Type Algorithm

1~30

If the downlink receive quality level of an AMR half rate call is DLAHSR SET greater DLAHSR EXQUAL GCELLP than this GBFDexQualHi BSC6900 HIGHTHR WR3(Opti parameter 117601 ghThred ED onal) , the call needs to undergo Huawei power control generatio n III.

HUAWEI III Power Interval Control Type Algorithm

1~30

If the downlink receive quality level of an AMR half rate call is DLAHSR SET smaller DLAHSR EXQUAL GCELLP than this GBFDexQualLo BSC6900 LOWTHR WR3(Opti parameter 117601 wThred ED onal) , the call needs to undergo Huawei power control generatio n III.

HUAWEI III Power Interval Control Type Algorithm

1~30

DLCI

The Identifier ADD of Data BSC6900 NSVC(Ma Link ndatory) Connectio n

SET DLCOEF Fast DL BSCPSS FICIENTT Priority BSC6900 OFTPAR SRAPIDA Decision A(Optiona DJ Threshold l)

ID of the data link connectio n of the NSVC. It is an interworki ng parameter which must be consistent on the BSC and the peer. If the ratio of downlink flux to uplink flux is greater than or equal to the threshold during the fast flux measure ment, the downlink services takes priority.

GBFD510002

Gb Over FR

Interval Type

16~1007

GBFD119501

Adaptive Adjustme nt of Interval Uplink Type and Downlink Channels

1~255

Support SET Whether DLDCSP Downlink GCELLG the cell BSC6900 T DualPRS(Opti supports Carrier onal) DLDC

GBFD510802

UNSUPP Dual ORT(Not Carriers Enumerati Support), in on Type SUPPOR Downlink T(Support )

Threshold for downlink edge handover. If the downlink receive level remains less than this threshold for a period of Edge HO SET time, the DLEDGE DL GCELLH edge BSC6900 THRES RX_LEV OBASIC( handover Threshold Optional) is triggered. If the PBGT handover algorithm is enabled, this threshold can be decrease d accordingl y. If the PBGT

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

III DL DLFILTA Filter DJFACT Adjust OR Factor

Filter adjustme nt factor for downlink power control. Setting this parameter high helps to smooth the filtered values SET and to GCELLP reduce GBFDBSC6900 WR3(Opti the 117601 onal) impact of poor measure ment reports on the filtered values. Setting this parameter low helps to draw the filtered values

HUAWEI III Power Interval Control Type Algorithm

1~10

Upper quality threshold for Huawei power control generatio n III on a full rate call. If the downlink DLFSRE SET receive DLFSRex XQUALHI GCELLP quality GBFDQualHigh BSC6900 GHTHRE WR3(Opti level of a 117601 Thred D onal) full rate call is greater than this threshold, the call needs to undergo Huawei power control generatio n III.

HUAWEI III Power Interval Control Type Algorithm

1~30

Lower quality threshold for Huawei power control generatio n III on a full rate call. If the downlink DLFSRE SET receive DLFSRex XQUALL GCELLP quality GBFDQualLowT BSC6900 OWTHRE WR3(Opti level of a 117601 hred D onal) full rate call is smaller than this threshold, the call needs to undergo Huawei power control generatio n III.

HUAWEI III Power Interval Control Type Algorithm

1~30

Expanded size of the GPRS RLC window. This parameter is used to expand the size of the GRPS RLC Downlink window. GPRS The SET TBF expanded DlGprsTbf GCELLP Window window GBFDExpandO BSC6900 SOTHER Expansio size 114101 p PARA(Op n breaks tional) Optimizati the on restriction s of 64 defined in the protocol and reduces the probability of GRPS RLC window stopping.

GPRS

Interval Type

0~127

Upper quality threshold for Huawei power control generatio n III on a half rate call. If the downlink DLHSRE SET receive DLHSRex XQUALHI GCELLP quality GBFDQualHigh BSC6900 GHTHRE WR3(Opti level of a 117601 Thred D onal) half rate call is greater than this threshold, the call needs to undergo Huawei power control generatio n III.

HUAWEI III Power Interval Control Type Algorithm

1~30

Lower quality threshold for Huawei power control generatio n III on a half rate call. If the downlink DLHSRE SET receive DLHSRex XQUALL GCELLP quality GBFDQualLowT BSC6900 OWTHRE WR3(Opti level of a 117601 hred D onal) half rate call is smallter than this threshold, the call needs to undergo Huawei power control generatio n III.

HUAWEI III Power Interval Control Type Algorithm

1~30

Adjustme nt hysteresis 1 of AMR downlink coding rate (full rate). According to a certain algorithm and the radio quality AMR DL SET indication Coding DLHYSTF GCELLC (RQI) in GBFDRate BSC6900 1 CAMR(O the call 115501 adj.hyst1[ ptional) measure F] ment report, the MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt

AMR FR

Interval Type

0~15

Adjustme nt hysteresis 2 of AMR downlink coding rate (full rate). According to a certain algorithm and the radio quality AMR DL SET indication Coding DLHYSTF GCELLC (RQI) in GBFDRate BSC6900 2 CAMR(O the call 115501 adj.hyst2[ ptional) measure F] ment report, the MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt

AMR FR

Interval Type

0~15

Adjustme nt hysteresis 3 of AMR downlink coding rate (full rate). According to a certain algorithm and the radio quality AMR DL SET indication Coding DLHYSTF GCELLC (RQI) in GBFDRate BSC6900 3 CAMR(O the call 115501 adj.hyst3[ ptional) measure F] ment report, the MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt

AMR FR

Interval Type

0~15

DLHYST H1

Adjustme nt hysteresis 1 of AMR downlink coding rate (half rate). According to a certain algorithm and the radio quality AMR DL SET indication Coding GCELLC (RQI) in GBFDRate BSC6900 CAMR(O the call 115502 adj.hyst1[ ptional) measure H] ment report, the MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt

AMR HR

Interval Type

0~15

DLHYST H2

Adjustme nt hysteresis 2 of AMR downlink coding rate (half rate). According to a certain algorithm and the radio quality AMR DL SET indication Coding GCELLC (RQI) in GBFDRate BSC6900 CAMR(O the call 115502 adj.hyst2[ ptional) measure H] ment report, the MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt

AMR HR

Interval Type

0~15

DLHYST H3

Adjustme nt hysteresis 3 of AMR downlink coding rate (half rate). According to a certain algorithm and the radio quality AMR DL SET indication Coding GCELLC (RQI) in GBFDRate BSC6900 CAMR(O the call 115502 adj.hyst3[ ptional) measure H] ment report, the MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt

AMR HR

Interval Type

0~15

DLHYST WB1

Adjustme nt hysteresis 1 of AMR downlink coding rate (wide band). According to a certain algorithm and the radio quality AMR DL SET indication Coding GCELLC (RQI) in GBFDRate BSC6900 CAMR(O the call 115507 adj.hyst1[ ptional) measure WB] ment report, the MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt

WB AMR

Interval Type

0~15

DLHYST WB2

Adjustme nt hysteresis 2 of AMR downlink coding rate (wide band). According to a certain algorithm and the radio quality AMR DL SET indication Coding GCELLC (RQI) in GBFDRate BSC6900 CAMR(O the call 115507 adj.hyst2[ ptional) measure WB] ment report, the MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt

WB AMR

Interval Type

0~15

Threshold for determini ng whether downlink interferen ce exists. If the downlink level is equal to or greater than "Interf.of SET DL Level DLINTER Interf.of GCELLC Threshold FLEVLIMI DL Level BSC6900 HMGAD( " and the T Threshold Optional) downlink quality level is equal to or greater than "Interf.of DL Qual.Thre shold", downlink interferen ce exists. The value range 0 to 63 is

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

Interf.of SET DLINTER DL GCELLC FQUALLI BSC6900 Qual.Thre HMGAD( MIT shold Optional)

SET 2G Cell GCELLH DlLdrThrd DL Basic BSC6900 OINTERR 2GCell Congest ATLDB(O Thred ptional)

Threshold for determini ng whether downlink interferen ce exists. If the downlink level is equal to or greater than "Interf.of DL Level Threshold " and the downlink quality level is equal to or greater than "Interf.of DL Qual.Thre shold", downlink interferen ce exists. When the downlink load of a cell is larger than the value of this parameter and is smaller than "2G Cell DL Overload Congest Thred", the downlink of the cell is in the basic congestio

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

GBFD114322

GSM/WC DMA Interval Load Type Based Handover

1~100

Number of measure ment reports sampled for averaging downlink signal strength. A single measure ment report Filter SET may not DLLEVFI Length for GCELLP reflect the BSC6900 LTLEN DL WR2(Opti actual RX_LEV onal) network situations accurately . Therefore , the BSC needs to average the measured values in several successiv e measure ment Lower voice quality threshold associate d with the automatic adjustme nt of the AMR Downlink downlink SET Long-term handover DLLTFER GCELLC FER BSC6900 threshold. LOWTH CAMR(O Lower The value ptional) Threshold of this parameter must be smaller than or equal to the value of Downlink Long-term FER

GBFD110703

Enhanced Power Interval Control Type Algorithm

1~20

GBFD115506

AMR Coding Rate Interval Threshold Type Adaptive Adjustme nt

2~255

Target value of the voice quality automatic Downlink SET ally DLLTFER Long-term GCELLC GBFDBSC6900 adjusted TGT FER CAMR(O 115506 through Target ptional) the downlink threshold of AMR handover

AMR Coding Rate Interval Threshold Type Adaptive Adjustme nt

2~255

Upper voice quality threshold Downlink associate SET Long-term d with the DLLTFER GCELLC GBFDFER BSC6900 automatic UPTH CAMR(O 115506 Upper adjustme ptional) Threshold nt of the AMR handover downlink threshold.

AMR Coding Rate Interval Threshold Type Adaptive Adjustme nt

2~255

Factor of downlink threshold adjustme nt. It indicates Downlink SET the linear DLLTTHA Threshold GCELLC relation GBFDBSC6900 DJFA Adjust CAMR(O between 115506 Factor ptional) the threshold adjustme nt value and the logarithmi c FER.

AMR Coding Rate Interval Threshold Type Adaptive Adjustme nt

2~255

Maximum step by which to SET DLMAXD decrease DLMAXD GCELLP GBFDOWNSTE BSC6900 downlink ownStep WR3(Opti 117601 P power onal) according to signal strength

HUAWEI III Power Interval Control Type Algorithm

1~30

Maximum step by which to SET increase DLMAXU DLMAXU GCELLP GBFDBSC6900 downlink PSTEP pStep WR3(Opti 117601 power onal) according to signal strength

HUAWEI III Power Interval Control Type Algorithm

1~30

When the downlink load of a cell is 2G Cell SET greater DL GCELLH than the DlOlcThrd GBFDOverload BSC6900 OINTERR value, the 2GCell 114322 Congest ATLDB(O downlink Thred ptional) of the cell is in the overload congestio n status.

GSM/WC DMA Interval Load Type Based Handover

1~100

Number of downlink measure ment reports that the BSC predicts. The BSC takes a while to confirm the power control SET effect of a DL MR. DLPRED GCELLP power GBFDNumber BSC6900 LEND WR2(Opti control 110703 Predicted onal) command . Thus, the BSC makes a power control decision based on a measure ment report that lags behind the changes

Enhanced Power Interval Control Type Algorithm

0~3

Quality level threshold for decreasin g downlink signal power. If the BTS transmits signals at a quality level less than this SET threshold, DL Qual. GCELLP DLQHIGH the BSC GBFDUpper BSC6900 WRBASI THRED decrease 110703 Threshold C(Optiona s the l) power of the BTS. If (downlink receive level "MAX Down Adj. PC Value by Qual.") < "DL RX_LEV Lower Threshold ", the

Enhanced Power Interval Control Type Algorithm

0~7

Quality level threshold for increasing downlink signal power. If the BTS transmits signals at a quality level greater than this SET threshold, DL Qual. GCELLP DLQLOW the BSC GBFDLower BSC6900 WRBASI THRED increases 110703 Threshold C(Optiona the power l) of the BTS. If (downlink receive level + "MAX Up Adj. PC Value by Qual.") > "DL RX_LEV Upper Threshold ", the BSC does

Enhanced Power Interval Control Type Algorithm

0~7

Number of measure ment reports sampled for averaging downlink signal quality. A single measure ment report SET may not Filter DLQUAFI GCELLP reflect the GBFDLength for BSC6900 LTLEN WR2(Opti actual 110703 DL Qual. onal) network situations accurately . Therefore , the BSC needs to average the measured values in several successiv e measure ment

Enhanced Power Interval Control Type Algorithm

1~20

During downlink power control, if the downlink receive quality level is equal to or greater than "DL Qual, bad Trig SET Threshold DL Qual. DLQUAL GCELLP ", "DL GBFDBad Trig BSC6900 BADTRIG WR2(Opti RX_LEV 110703 Threshold onal) Upper Threshold " is increased by "DL Qual. Bad UpLEVDif f" to further increase the expected downlink power level.

Enhanced Power Interval Control Type Algorithm

0~7

During downlink power control, if the downlink receive quality level is equal to or greater than "DL Qual, bad Trig DL Qual. SET Threshold DLQUAL Bad GCELLP ", "DL GBFDBADUPL BSC6900 UpLEVDif WR2(Opti RX_LEV 110703 EV f onal) Upper Threshold " is increased by "DL Qual. Bad UpLEVDif f" to further increase the expected downlink power level.

Enhanced Power Interval Control Type Algorithm

0~63

Downlink quality threshold for emergenc y handover. This parameter is represent ed as the product of 10 and a quality SET level that DLQUALI DL Qual. GCELLH ranges BSC6900 MIT Threshold OEMG(O from 0 to ptional) 7. The emergenc y handover can be triggered only when the downlink receive quality of an MS is greater(in dicate bad quality)

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

Downlink quality limit for emergenc y handover in an AMR full rate call. The value of this parameter correspon ds to the quality SET levels (0 DLQUALI DL Qual. GCELLA to 7) MITAMRF Limit for BSC6900 MRQUL( multiplied R AMR FR Optional) by 10. An emergenc y handover can be triggered only when the downlink reception quality of an MS is higher than the value of this

GBFD115501 GBFD510501 GBFD110601

AMR FR HUAWEI II Interval Handover Type HUAWEI I Handover

0~70

Downlink quality limit for emergenc y handover in an AMR half rate call. The value of this parameter correspon ds to the quality SET levels (0 DLQUALI DL Qual. GCELLA to 7) MITAMR Limit for BSC6900 MRQUL( multiplied HR AMR HR Optional) by 10. An emergenc y handover can be triggered only when the downlink reception quality of an MS is higher than the value of this

GBFD115502 GBFD510501 GBFD110601

AMR HR HUAWEI II Interval Handover Type HUAWEI I Handover

0~70

This parameter specifies the downlink signal strength factor multiplied by 10 during the calculatio n of the downlink power SET control DLREXLE DLRexLe GCELLP step. The GBFDVADJFCT vAdjustFa BSC6900 WR3(Opti downlink 117601 R ctor onal) signal strength factor is a coefficient indicating how much the signal strength is considere d during the calculatio n of the downlink power

HUAWEI III Power Interval Control Type Algorithm

0~10

Length of the exponenti al filter for downlink signal strength. A single measure ment report may not reflect the actual SET DLREXLE DLRexLe network GCELLP GBFDVEXPFLT vExponen BSC6900 situations WR3(Opti 117601 LEN tFilterLen accurately onal) . Therefore , the BSC needs to filter the measured values in several successiv e measure ment reports to reflect the

HUAWEI III Power Interval Control Type Algorithm

0~19

Upper receive level threshold for downlink power control. If the downlink SET DLREXLE DLRexLe receive GCELLP GBFDVHIGHTH vHighThr BSC6900 level is WR3(Opti 117601 RED ed greater onal) than this threshold, the power of the downlink signal needs to be decrease d.

HUAWEI III Power Interval Control Type Algorithm

0~63

Lower receive level threshold for downlink power control. If the downlink SET DLREXLE DLRexLe receive GCELLP GBFDVLOWTH vLowthre BSC6900 level is WR3(Opti 117601 RED d smaller onal) than this threshold, the power of the uplink signal needs to be increased .

HUAWEI III Power Interval Control Type Algorithm

0~63

Length of the slide window filter for downlink signal strength. A single measure ment report may not reflect the actual SET DLREXLE DLRexLe network GCELLP GBFDVSLDWI vSlideWin BSC6900 situations WR3(Opti 117601 NDOW dow accurately onal) . Therefore , the BSC needs to filter the measured values in several successiv e measure ment reports to reflect the

HUAWEI III Power Interval Control Type Algorithm

1~20

This parameter specifies the downlink quality level factor multiplied by 10 during the calculatio n of the downlink power SET control DLREXQ DLRexQu GCELLP step. The GBFDUALADJF alAdjustF BSC6900 WR3(Opti downlink 117601 CTR actor onal) quality level factor is a coefficient indicating how much the quality level is considere d during the calculatio n of the downlink power control

HUAWEI III Power Interval Control Type Algorithm

0~10

Length of the exponenti al filter for downlink signal quality. A single measure ment report may not reflect the actual DLRexQu SET DLREXQ network alExpone GCELLP GBFDUALEXPF BSC6900 situations ntFilterLe WR3(Opti 117601 LTLEN accurately n onal) . Therefore , the BSC needs to filter the measured values in several successiv e measure ment reports to reflect the

HUAWEI III Power Interval Control Type Algorithm

0~19

Length of the slide window filter for downlink signal quality. A single measure ment report may not reflect the actual SET DLREXQ DLRexQu network GCELLP UALSLD alSlideWi BSC6900 situations WR3(Opti WINDOW ndow accurately onal) . Therefore , the BSC needs to filter the measured values in several successiv e measure ment reports to reflect the A power control step cannot exceed the step computed DLRXLEV III DL SET according PROTEC RexLev GCELLP BSC6900 to "III DL TFACTO Protect WR3(Opti RexLev R Factor onal) Protect Factor" and "III DL RexQual Protect Factor".

GBFD117601

HUAWEI III Power Interval Control Type Algorithm

1~20

GBFD117601

HUAWEI III Power Interval Control Type Algorithm

0~100

DLRXQU ALPROT ECTFAC TOR

III DL RexQual Protect Factor

A power control step cannot exceed the step computed SET according GCELLP GBFDBSC6900 to "III DL WR3(Opti 117601 RexLev onal) Protect Factor" and "III DL RexQual Protect Factor". Upper

HUAWEI III Power Interval Control Type Algorithm

0~100

threshold for downlink signal strength If the downlink received signal level is greater than this threshold, a power SET DL decrease GCELLP DLSSHIG RX_LEV GBFDis BSC6900 WRBASI HTHRED Upper computed 110703 C(Optiona Threshold . Then, l) the power is decrease d by the least of the power decrease, maximum power adjustme nt step allowed by the quality zone to

Enhanced Power Interval Control Type Algorithm

0~63

Lower threshold for downlink signal strength If the downlink received signal level is less than this threshold, a power SET DL increase GCELLP DLSSLO RX_LEV GBFDis BSC6900 WRBASI WTHRED Lower computed 110703 C(Optiona Threshold . Then, l) the power is increased by the least of the power increase, "MAX Up Adj. PC Value by RX_LEV", and "MAX Up Adj. PC Value by Qual.".

Enhanced Power Interval Control Type Algorithm

0~63

Time interval between sending of the Packet Uplink Ack/Nack message and setup of the DL TBF. After receiving the Packet Downlink SET Uplink TBF GCELLP DLTBFES Ack/Nack GBFDEstablish BSC6900 RIVATEO TDELAY message 119203 ment PTPARA( (FAI = 1), Delay Optional) the MS releases the UL TBF and starts to monitor CCCH. In this case, if the MS receives the downlink assignme nt message Interval for Download SET DLTESTR resending Test GCELLG ESENDIN BSC6900 downlink Resend SMR(Opti T test Interval onal) message s GBFD510301 GBFD510302

Extended Interval Uplink Type TBF

0~300

Public Voice Group Call Interval Service Type Public Voice Broadcast Service

0~255

Number of times of the BSC6900 resending downlink test message s after the downlink test function is enabled. If the BSC6900 Download SET does not DLTESTR Test GCELLG receive ESENDN BSC6900 Resend SMR(Opti any UM Number onal) response message from the MS at the preset interval, the BSC6900 releases the relevant voice group call service (VGCS) channel.

GBFD510301 GBFD510302

Public Voice Group Call Interval Service Type Public Voice Broadcast Service

1~255

DLTHF1

Adjustme nt threshold 1 of AMR downlink coding rate (full rate). According to a certain algorithm and the RQI in the call AMR DL SET measure Coding GCELLC ment GBFDBSC6900 Rate CAMR(O report, the 115501 adj.th1[F] ptional) MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt threshold of coding rate is the

AMR FR

Interval Type

0~63

DLTHF2

Adjustme nt threshold 2 of AMR downlink coding rate (full rate). According to a certain algorithm and the RQI in the call AMR DL SET measure Coding GCELLC ment GBFDBSC6900 Rate CAMR(O report, the 115501 adj.th2[F] ptional) MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt threshold of coding rate is the

AMR FR

Interval Type

0~63

DLTHF3

Adjustme nt threshold 3 of AMR downlink coding rate (full rate). The adjustme nt threshold s and the hysteresis of coding rate must AMR DL SET meet the Coding GCELLC following GBFDBSC6900 Rate CAMR(O conditions 115501 adj.th3[F] ptional) : AMR Coding Rate adj.th (n) < AMR Coding Rate adj.th (n + 1), n = 1 or 2; [AMR Coding Rate adj.th (n) + AMR Coding

AMR FR

Interval Type

0~63

DLTHH1

Adjustme nt threshold 1 of AMR downlink coding rate (half rate). According to a certain algorithm and the RQI in the call AMR DL SET measure Coding GCELLC ment GBFDBSC6900 Rate CAMR(O report, the 115502 adj.th1[H] ptional) MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt threshold of coding rate is the

AMR HR

Interval Type

0~63

DLTHH2

Adjustme nt threshold 2 of AMR downlink coding rate (half rate). According to a certain algorithm and the RQI in the call AMR DL SET measure Coding GCELLC ment GBFDBSC6900 Rate CAMR(O report, the 115502 adj.th2[H] ptional) MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt threshold of coding rate is the

AMR HR

Interval Type

0~63

DLTHH3

Adjustme nt threshold 3 of AMR downlink coding rate (half rate). According to a certain algorithm and the RQI in the call AMR DL SET measure Coding GCELLC ment GBFDBSC6900 Rate CAMR(O report, the 115502 adj.th3[H] ptional) MS and the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt threshold of coding rate is the

AMR HR

Interval Type

0~63

Adjustme nt threshold 1 of AMR downlink coding rate (wide band). According to a certain algorithm and the RQI in the call AMR DL SET measure Coding DLTHWB GCELLC ment GBFDRate BSC6900 1 CAMR(O report, the 115507 adj.th1[W ptional) MS and B] the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt threshold of coding rate is the

WB AMR

Interval Type

0~63

Adjustme nt threshold 2 of AMR downlink coding rate (wide band). According to a certain algorithm and the RQI in the call AMR DL SET measure Coding DLTHWB GCELLC ment GBFDRate BSC6900 2 CAMR(O report, the 115507 adj.th2[W ptional) MS and B] the BTS automatic ally adjust the current speech coding and decoding rate. The adjustme nt threshold of coding rate is the ADD MDU BTSANTF board EEDERB number RD(Optio when the Down nal) antenna GBFDDMDUA BSC6900 MDU A 111202 SET pass of BTSANTF downlink EEDERC tributary A ONNECT( is Optional) MDU selected ADD BTSANTF EEDERB RD(Optio nal) BSC6900 SET BTSANTF EEDERC ONNECT( Optional) board number when the antenna GBFD111202 pass of downlink tributary B is selected

WB AMR

Interval Type

0~63

O&M of BTS

Interval Type

0~255

DMDUB

Down MDU B

O&M of BTS

Interval Type

0~255

DN

Domain

SET BTSIPCL BSC6900 KPARA(M andatory)

SET Downlink DNDEFA GCELLP Default BSC6900 ULTCS SCS(Opti CS Type onal)

Clock domain required by the slave side in the 1588V2 protocol. This parameter is valid when the 1588CLK type is configure Coding scheme of the default GPRS downlink. Dynamic adjustme nt coding: the coding scheme used during initial access transmissi on. If the downlink uses the fixed coding scheme, the TBF uses the fixed coding

GBFD118620

Clock over IP support 1588V2

Interval Type

0~255

GBFD119106

Coding Scheme

CS1(CS1) , CS2(CS2) Enumerati , on Type CS3(CS3) , CS4(CS4)

Default coding scheme of the downlink EDGE link. If the downlink adopts the dynamic adjustme nt coding scheme, this SET Downlink parameter GCELLE DNDEFA Default can be BSC6900 GPRSPA ULTMCS MCS used to RA(Optio Type set the nal) coding scheme for transmissi on during initial access. If the downlink uses the fixed coding scheme, the TBF uses the

GBFD114201 GBFD119106 GBFD114201 GBFD119106

EGPRS Coding Scheme EGPRS Coding Scheme

MCS1(M CS1), MCS2(M CS2), MCS3(M CS3), MCS4(M CS4), Enumerati MCS5(M on Type CS5), MCS6(M CS6), MCS7(M CS7), MCS8(M CS8), MCS9(M CS9)

Default coding scheme used on the downlink EGPRS2A link. If the downlink uses the dynamic coding scheme, this Downlink SET parameter DNE2AD EGPRS2GCELLE specifies GBFDEFAULT A Default BSC6900 GPRSPA 510804 the MCS MCS RA(Optio coding Type nal) scheme that is used for the transmissi on in initial access. If the downlink uses the fixed coding scheme, the TBF

MCS1(M CS1), MCS2(M CS2), MCS3(M CS3), MCS4(M CS4), MCS7(M CS7), MCS8(M CS8), DAS5(DA Downlink Enumerati S5), EGPRS2on Type DAS6(DA A S6), DAS7(DA S7), DAS8(DA S8), DAS9(DA S9), DAS10(D AS10), DAS11(D AS11), DAS12(D AS12)

Downlink EGPRS2DNE2AFI A Fixed XMCS MCS Type

Downlink DNFIXCS Fixed CS Type

Fixed coding scheme that is used on the downlink EGPRS2A link. If the downlink uses the fixed coding SET scheme, GCELLE this GBFDBSC6900 GPRSPA parameter 510804 RA(Optio can be nal) set MSC14, MSC78 or DAS512.. If the downlink uses the dynamic coding scheme, this parameter is set to UNFIXED . Adjustme nt mode of the downlink GPRS link coding scheme. If the GBFDfixed 114101 coding SET scheme is GBFDGCELLP used, this 119106 BSC6900 SCS(Opti parameter GBFDonal) is set to a 114101 GBFDvalue 119106 ranging from CS1 to CS4. If the dynamic coding scheme is used, this parameter is set to

MCS1(M CS1), MCS2(M CS2), MCS3(M CS3), MCS4(M CS4), MCS7(M CS7), MCS8(M CS8), DAS5(DA S5), Downlink DAS6(DA Enumerati EGPRS2S6), on Type A DAS7(DA S7), DAS8(DA S8), DAS9(DA S9), DAS10(D AS10), DAS11(D AS11), DAS12(D AS12), UNFIXED (UNFIXE D)

GPRS Coding Scheme GPRS Coding Scheme

CS1(CS1) , CS2(CS2) , CS3(CS3) Enumerati , on Type CS4(CS4) , UNFIXED (UNFIXE D)

Coding scheme of the downlink EDGE link. If the downlink uses the fixed coding scheme, this parameter SET Downlink is set to a GCELLE DNFIXMC Fixed value BSC6900 GPRSPA S MCS ranging RA(Optio Type from nal) MCS1 to MCS9. If the downlink uses the dynamic adjustme nt coding scheme, this parameter is set to UNFIXED

GBFD114201 GBFD119106 GBFD114201 GBFD119106

EGPRS Coding Scheme EGPRS Coding Scheme

MCS1(M CS1), MCS2(M CS2), MCS3(M CS3), MCS4(M CS4), MCS5(M CS5), Enumerati MCS6(M on Type CS6), MCS7(M CS7), MCS8(M CS8), MCS9(M CS9), UNFIXED (UNFIXE D)

DL PC DNPCEN Allowed

SET GCELLB BSC6900 ASICPAR A(Optiona l)

Whether to allow BTS power control

GBFD110703 GBFD117601

Enhanced Power Control Algorithm Enumerati NO(No), HUAWEI on Type YES(Yes) III Power Control Algorithm

Whether to prohibit sending point-topoint short message s. If necessary , this parameter is used for Short SET controlling DNSEND Message GCELLC GBFDBSC6900 whether SMDIS Downlink CAD(Opti 110203 to send Disabled onal) downlink short message s from a specific cell so as to ensure sufficient radio channel resources for normal calls.

Point To Point Short Enumerati NO(No), Message on Type YES(Yes) Service (TS21, TS22)

Delay of releasing the downlink TBF. After the last downlink RLC data block is transmitte d on the network side and all the transmitte SET Release d GCELLP DNTBFR Delay of downlink GBFDBSC6900 RIVATEO ELDELAY Downlink 114101 data PTPARA( TBF blocks are Optional) received, the MS is not informed to stop this downlink TBF. Instead, the state of the last data block is forcibly set to "not received"

GPRS

Interval Type

0~5000

DNTHDC SDEGRA DE1

DNTHDC SDEGRA DE2

Retransmi ssion threshold when the coding mode of the downlink TBF is changed from CS2 to CS1. Downlink SET When the TBF GCELLP downlink Threshold BSC6900 SCS(Opti TBF from CS2 onal) retransmi to CS1 ssion rate is greater than or equals to this value, the coding mode of the TBF is changed from CS2 to CS1. Retransmi ssion threshold when the coding mode of the TBF is changed from CS3 to CS2. Downlink When the SET TBF TBF GCELLP Threshold BSC6900 retransmi SCS(Opti from CS3 ssion rate onal) to CS2 is greater than or equals to this value, the coding mode of the TBF is changed from CS3 to CS2.

GBFD119106

Coding Scheme

Interval Type

0~64

GBFD118901 GBFD119106 GBFD118901 GBFD119106

CS-3/CS4 Coding Scheme Interval CS-3/CS- Type 4 Coding Scheme

0~64

DNTHDC SDEGRA DE3

DNTHDC SUPGRA DE1

Retransmi ssion threshold when the coding mode of the downlink TBF is changed from CS4 to CS3. Downlink SET When the TBF GCELLP downlink Threshold BSC6900 SCS(Opti TBF from CS4 onal) Retransmi to CS3 ssion rate is greater than or equals to this value, the coding mode of the TBF is changed from CS4 to CS3. Retransmi ssion threshold when the coding mode of the downlink TBF is changed from CS1 Downlink to CS2. SET TBF When the GCELLP Threshold BSC6900 TBF SCS(Opti from CS1 retransmi onal) to CS2 ssion rate is less than or equals to this value, the coding mode of the TBF is changed from CS1 to CS2.

GBFD118901 GBFD119106 GBFD118901 GBFD119106

CS-3/CS4 Coding Scheme Interval CS-3/CS- Type 4 Coding Scheme

0~64

GBFD119106

Coding Scheme

Interval Type

0~64

DNTHDC SUPGRA DE2

DNTHDC SUPGRA DE3

Retransmi ssion threshold when the coding mode of the TBF is changed from CS2 to CS3. When the Downlink SET downlink TBF GCELLP TBF Threshold BSC6900 SCS(Opti retransmi from CS2 onal) ssion rate to CS3 is less than or equals to CS2 to CS1, the coding mode of the TBF is changed from CS2 to CS3. Retransmi ssion threshold when the coding mode of the downlink TBF is changed from CS3 to CS4. When the Downlink SET downlink TBF GCELLP TBF Threshold BSC6900 SCS(Opti retransmi from CS3 onal) ssion rate to CS4 is less than or equals to this value, the coding mode of the downlink TBF is changed from CS3 to CS4.

GBFD118901 GBFD119106 GBFD118901 GBFD119106

CS-3/CS4 Coding Scheme Interval CS-3/CS- Type 4 Coding Scheme

0~64

GBFD118901 GBFD119106 GBFD118901 GBFD119106

CS-3/CS4 Coding Scheme Interval CS-3/CS- Type 4 Coding Scheme

0~64

Enable DOOR_E Door ADD NGINE_M Status BSC6900 EMU(Opti ASK Alarm onal) Reporting

Door status alarm switch

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

DOUBLE Double ANTENN Antenna AGAIN Gain

Dualantenna gain used SET to GCELLP estimate GBFDBSC6900 WRBASI the 117602 C(Optiona downlink l) power during assignme nt

Active Power Control

Interval Type

0~255

DPC

DSP ADD code[Who BSC6900 N7DPC(M le andatory) Number]

DSP ADD code[Divi DPCDNF BSC6900 N7DPC(M ded andatory) Number]

As an integer, the DSP code can be expresse d by a decimal digit or a hexadeci mal digit. If the DSP code is expresse d by a hexadeci mal digit, H' is added before the DSP code expresse d in the format of segments 8-8-8

GBFD111804 GBFD111806

A Interface Protocol Process Interval STP(Sign Type aling Transport Point)

1~167772 15

GBFD111804

A Interface Protocol Process

String Type

None

DPC DPCGIDX Group Index

As a key field for identifying the block of A interface CIC BLK status, it GBFDBSC6900 ACIC(Ma indicates 111803 ndatory) the DPC group index of the circuit ID of the A interface to be of Index the DPC group. ADD see "ADD BSC6900 AE1T1(O GCNNOD ptional) E" command . Index of a DPC group. When multiple DPCs or one DPC serves as a logical entity, this logical entity is called a DPC group. ADD When the GCNNOD MSC pool BSC6900 E(Mandat function is ory) activated, the user plane resources on the A interface are shared among the MSCs in the pool, and thus load balancing is achieved.

A Interface Interval Circuit Type Managem ent

0~31

DPC DPCGIDX Group Index

GBFD111803

A Interface Interval Circuit Type Managem ent

0~31

DPC DPCGIDX Group Index

GBFD117401

MSC Pool

Interval Type

0~31

DPCT

DPX

DSP type. STP: indicates the signaling transfer point. A: indicates the signaling point of the A interface control signaling ADD plane. DSP type BSC6900 N7DPC(M IUR_G: andatory) indicates the signaling point of the base station controller that is connecte d to the BSC. LB: indicates the signaling point of ADD N7DPC(M andatory) ADD MTP3RT( Mandator y) ADD MTP3LKS The DSP (Mandator index DSP BSC6900 y) uniquely index ADD identifies M3DE(Ma a DSP. ndatory) ADD GCNNOD E(Mandat ory) ADD GEXTSM LC(Mand

GBFD111804 GBFD111806

A Interface STP(STP) Protocol , A(A), Process Enumerati IUR_G(IU STP(Sign on Type R_G), aling LB(LB) Transport Point)

GBFD111804 GBFD118602 GBFD118622

A Interface Protocol Interval Process Type A over IP A IP over E1/T1

0~186

DPX

DPX

ADD GNRNC( BSC6900 Mandator y)

Iur-g DPC index of a MRFDneighbori 211402 ng RNC

MBSC Interval Load Type Balancing

0~182

DRHOLE VRANGE

DROPCT RLABISC ONNFAIL

Maximum signal level difference Directed between ADD Retry the G2GNCE Handover BSC6900 neighbor LL(Option Level cell and al) Range the serving cell for triggering directed Whether to optimize the call drops resulting from Abis territorial link fault. The value 0 means "optimize" and 1 Drop SET means Optimize GCELLS BSC6900 "not ABIS Link OFT(Opti optimize". Failure onal) If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~128

GBFD111004

Radio Dedicated Interval Channel Type Managem ent

0~1

DROPCT RLCONN FAILHOA CCFAIL

Drop Optimize Conn Fail[HO access fail]

Whether to optimize the call drops resulting from connectio n failure (handover access failure). The value 0 means "optimize" SET and 1 GCELLS GBFDBSC6900 means OFT(Opti 111004 "not onal) optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from connectio n failure, operation and maintena nce (OM) interventi Drop on. The Optimize SET value 0 DROPCT Conn GCELLS means GBFDRLCONN BSC6900 Fail[OM OFT(Opti "optimize" 111004 FAILOM interventi onal) and 1 on] means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from a connectio n failure except for handover access failure, OM interventi DROPCT Drop SET on, radio RLCONN Optimize GCELLS link GBFDBSC6900 FAILOTH Conn OFT(Opti failure, 111004 ER Fail[other] onal) and unavailabi lity of radio resources . The value 0 means "optimize" and 1 means "not optimize". If the value of this

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from connectio n failure (radio link failure). The value 0 means Drop "optimize" DROPCT SET Optimize and 1 RLCONN GCELLS GBFDConn BSC6900 means FAILRLF OFT(Opti 111004 Fail[radio "not AIL onal) link fail] optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from connectio n failure (unavaila bility of radio resources ). The Drop value 0 DROPCT Optimize SET means RLCONN Conn GCELLS GBFDBSC6900 "optimize" FAILRRN Fail[resou OFT(Opti 111004 and 1 OTAVL rce not onal) means available] "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from equipmen t fault. The value 0 means "optimize" and 1 Drop SET DROPCT means Optimize GCELLS GBFDRLEQUIP BSC6900 "not Equipmen OFT(Opti 111004 FAIL optimize". t Failure onal) If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from error indication (unsolicite d DM response) . The value 0 Drop means Optimize SET DROPCT "optimize" Err GCELLS GBFDRLERRIN BSC6900 and 1 Ind[unsoli OFT(Opti 111004 DDMRSP means cited DM onal) "not response] optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from error indication (sequenc e error). The value 0 means "optimize" Drop DROPCT SET and 1 Optimize RLERRIN GCELLS means GBFDErr BSC6900 DSEQER OFT(Opti "not 111004 Ind[seque R onal) optimize". nce error] If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics

Radio Dedicated Interval Channel Type Managem ent

0~1

DROPCT RLERRIN DT200

DROPCT RLFORC HOFAIL

Whether to optimize the call drops resulting from error indication (T200 timeout). The value 0 means "optimize" Drop SET and 1 Optimize GCELLS means Err BSC6900 OFT(Opti "not Ind[T200 onal) optimize". timeout] If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics Whether to optimize the call drops resulting from forced handover failure. The value 0 means Drop "optimize" SET Optimize and 1 GCELLS Forced BSC6900 means OFT(Opti Handover "not onal) Failure optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the

GBFD111004

Radio Dedicated Interval Channel Type Managem ent

0~1

GBFD111004

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from incomingBSC handover timeout. The value 0 means Drop "optimize" SET DROPCT Optimize and 1 GCELLS GBFDRLINBSC Into-BSC BSC6900 means OFT(Opti 111004 HO Handover "not onal) Timeout optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from outgoing internal inter-cell handover timeout. The value 0 means Drop "optimize" DROPCT SET Optimize and 1 RLINTRA GCELLS GBFDIntra-BSC BSC6900 means BSCOUT OFT(Opti 111004 Handover "not HO onal) Timeout optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from intracell handover timeout. The value 0 means "optimize" Drop SET and 1 DROPCT Optimize GCELLS means GBFDRLINTRA Intra-Cell BSC6900 OFT(Opti "not 111004 CELLHO Handover onal) optimize". Timeout If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from no MS measure ment reports for a long time. The value 0 Drop means SET Optimize "optimize" DROPCT GCELLS GBFDNo MR for BSC6900 and 1 RLNOMR OFT(Opti 111004 Long means onal) Time "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics

Radio Dedicated Interval Channel Type Managem ent

0~1

Whether to optimize the call drops resulting from outgoingBSC handover timeout. The value 0 means Drop "optimize" SET DROPCT Optimize and 1 GCELLS GBFDRLOUTB Out-BSC BSC6900 means OFT(Opti 111004 SCHOT8 Handover "not onal) Timeout optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics

Radio Dedicated Interval Channel Type Managem ent

0~1

DROPCT RLRELIN D

DROPCT RLRESC HK

Whether to optimize the call drops resulting from release indication s. The value 0 means "optimize" Drop SET and 1 Optimize GCELLS BSC6900 means Release OFT(Opti "not Indication onal) optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the Whether to optimize the call drops resulting from resource check. The value 0 means "optimize" and 1 Drop SET means Optimize GCELLS BSC6900 "not Resource OFT(Opti optimize". Check onal) If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics

GBFD111004

Radio Dedicated Interval Channel Type Managem ent

0~1

GBFD111004

Radio Dedicated Interval Channel Type Managem ent

0~1

Packet ADD discard PORTFL DROPPK threshold BSC6900 OWCTRL TTHD0 of queue PARA(Op 0 [ms] tional)

Packet ADD discard PORTFL DROPPK threshold BSC6900 OWCTRL TTHD1 of queue PARA(Op 1 [ms] tional)

Packet ADD discard PORTFL DROPPK threshold BSC6900 OWCTRL TTHD2 of queue PARA(Op 2 [ms] tional)

If the duration for buffering the data in queue 0 is more than or equals to the value of this parameter , the subseque nt packets added to queue 0 are discarded If the duration for buffering the data in queue 1 is more than or equals to the value of this parameter , the subseque nt packets added to queue 1 are discarded If the duration for buffering the data in queue 2 is more than or equals to the value of this parameter , the subseque nt packets added to queue 2 are discarded

None

None

Interval Type

10~150

MRFD211503

2G/3G CoTransmis sion Resource Interval s Type Managem ent on MBSC

10~150

MRFD211503

2G/3G CoTransmis sion Resource Interval s Type Managem ent on MBSC

10~150

Packet ADD discard PORTFL DROPPK threshold BSC6900 OWCTRL TTHD3 of queue PARA(Op 3 [ms] tional)

Packet ADD discard PORTFL DROPPK threshold BSC6900 OWCTRL TTHD4 of queue PARA(Op 4 [ms] tional)

Packet ADD discard PORTFL DROPPK threshold BSC6900 OWCTRL TTHD5 of queue PARA(Op 5 [ms] tional)

If the duration for buffering the data in queue 3 is more than or equals to the value of this parameter , the subseque nt packets added to queue 3 are discarded If the duration for buffering the data in queue 4 is more than or equals to the value of this parameter , the subseque nt packets added to queue 4 are discarded If the duration for buffering the data in queue 5 is more than or equals to the value of this parameter , the subseque nt packets added to queue 5 are discarded

MRFD211503

2G/3G CoTransmis sion Resource Interval s Type Managem ent on MBSC

10~150

MRFD211503

2G/3G CoTransmis sion Resource Interval s Type Managem ent on MBSC

10~150

MRFD211503

2G/3G CoTransmis sion Resource Interval s Type Managem ent on MBSC

10~150

This parameter specifies Drop SET the DROPPW Power BTSBAKP interval at GBFDRINTERV Time BSC6900 WR(Optio which the 111605 AL Interval[T nal) power of 3] a TRX is continuall y This parameter specifies Drop SET the delay DROPPW Power BTSBAKP time GBFDRSTART BSC6900 Start WR(Optio before 111605 TIME Time[T1] nal) decreasin g the power of the TRXs. This parameter specifies SET the step BTSBAKP by which GBFDBSC6900 WR(Optio the power 111605 nal) of a TRX is decrease d at a

Active Backup Power Control

Interval Type

1~60

Active Backup Power Control

Interval Type

0~12

Drop DROPPW Power RSTEP Step

Active Backup Power Control

Interval Type

2~10

DRXEN

SMCBC DRX

Whether to support the discontinu ous reception mechanis m (DRX). To reduce the power consumpti on, the DRX is introduce d into the SET GSM GCELLO Specificati GBFDBSC6900 THEXT(O on. MSs 113602 ptional) supportin g the DRX can consume less power to receive interested broadcast message s. This prolongs the service time of MS

Simplified Enumerati NO(No), Cell on Type YES(Yes) Broadcast

Duration of the timer for entering the DRX mode. DRX is the parameter in the cell broadcast message. It indicates nonSET continuou Max. DRXTIME GCELLP s Duration BSC6900 RMAX SBASE(O receiving of DRX ptional) mode. When the MS is switched from the packet transmissi on mode to the idle mode, the MS needs to maintain the none DRX mode for Whether to start the dehumidifi cation equipmen t of the BTS. In multimode Dehumidif SET scenario, ication BTSOUT the value DRYSET BSC6900 Equipmen PUT(Opti of this t onal) parameter in one mode must be the same as the value of the correspon ding parameter

GBFD114802

0(0), 1(1), Discontin 2(2), 4(4), uous Enumerati 8(8), Reception on Type 16(16), (DRX) 32(32), 64(64)

GBFD111202

O&M of BTS

INACTIV E(Inactive Enumerati ), on Type ACTIVE( Active)

DS1

ADD E1T1 port BSC6900 PPPLNK( No. Optional)

DS1

ADD E1T1 port BSC6900 MPLNK(O No. ptional)

DSCP

ADD SCTPLN Differentia K(Optiona ted l) BSC6900 Service SET Codepoint PHBMAP( Mandator y)

DSCP

Differentia ted PING services BSC6900 IP(Option code al) point

Number of the E1T1 port for bearing the PPP Number of the E1T1 port for bearing the PPP link The DSCP is a field of the IP data packet. It is used to assign the differentia ted service to the communi cation networks. The DSCP code is used to label each data packet on the network and allocate the correspon ding service levels. In the same network environm Service code of the PING command , used to identify the PING command

None

None

Interval Type

0~335

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

0~335

GBFD118602

A over IP

Interval Type

0~63

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

0~63

DSCP

Differentia ted service Differentia SET code is ted DSCPMA used to BSC6900 Service P(Mandat identify Codepoint ory) the service priority of the user.

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

0~63

DSCP

DSCP

SET BTSVLAN (Optional) BSC6900 IMP BTSVLAN (Optional)

DSCP to be contained in the header of an IP packet. According to this parameter , the router provides differentia ted GBFDservices 118605 for packet streams. If this parameter is greater, the service level is higher. This parameter is valid only when the transport

IP QOS

Interval Type

0~63

DSPKIFF DSP OFFTIME Kickoff R Timer

SET BSCPSS BSC6900 OFTPAR A(Optiona l)

DSPN

DSP No.

DLD TCFILE( BSC6900 Mandator y)

Duration for recoverin g all the DSPs. This timer is started when the first DSP is recovered . When all the DSPs of the local subrack are recovered or the timer expires, the timer is stopped. The cells are distribute d on the recovered Number of the DSP. If you do not specify this parameter , all DSPs are Meanings

GBFD114101

GPRS

Interval Type

1~3600

MRFD210301

Configura tion Interval Managem Type ent

0~27

DSPN

DSP No.

:DSP No. Value range:0~2 1 SET Content:n MRFDBSC6900 TCTYPE( one 210301 Optional) Recomm ended value(def ault value):no ADD OBJALM BSC6900 SHLD(Ma ndatory) Number of the DSP MRFDwhere the 210304 alarm is generated

Configura tion Interval Managem Type ent

0~21

DSPN

DSP No.

Faulty Interval Managem Type ent

0~27

DSPN

DSP No.

SET TCPLYV OICE(Ma BSC6900 ndatory) SET TCPARA( Optional)

Number of the DSP in the DPU board

MRFD210301

Configura tion Interval Managem Type ent

0~21

DSPNO

DSP No.

SET Target PSCELLT BSC6900 DSP ODSP(Ma number ndatory)

GBFD114101

GPRS

Interval Type

0~21

DSPREC DSP OVERTIM Recover ER Timer

This parameter specifies the value of the timer set to wait the fault recovery before the cell redistribut ion on the DSP. When a SET fault is BSCPSS detected GBFDBSC6900 OFTPAR on a DSP, 114101 A(Optiona this timer l) starts. If the fault is recovered before the timer expires, the cells on the DSP are not be redistribut ed. Otherwise , the cell redistribut GBFD116101 MRFD210301

GPRS

Interval Type

0~30

DST

Whether daylight SET DaylightS saving BSC6900 TZ(Option ave time has al) to be used

Support of Daylight Saving NO(NO), Enumerati Time YES(YES on Type Configura ) tion Managem ent

DSTF

ULD Destinatio BTSDEV n File BSC6900 FILE(Man Name datory)

Name of the GBFDdestinatio 111202 n file

O&M of BTS

String Type

None

DSTIP

DSTIP

Destinatio ADD Destinatio n IP BSC6900 IPRT(Man n IP None address datory) address Destinatio ADD Destinatio n IP BTSBFD( GBFDn IP BSC6900 address Mandator 118609 Address of BFD y) Session. ADD BTSIPRT( Mandator y) Destinatio Destinatio ADD GBFDn IP BSC6900 BTSIPRT n IP 118601 Address BIND(Ma address ndatory) IMP BTSIPRT( Mandator None

None

IP Address Type

None

IP Fault IP Detection Address Based on Type BFD

None

DSTIP

IP Abis over Address IP Type

None

Destinatio ADD DSTMAS Subnet n address BSC6900 IPRT(Man K mask mask datory) ADD BTSIPRT( Mandator y) Destinatio ADD DSTMAS n Address BSC6900 BTSIPRT K Mask BIND(Ma ndatory) IMP BTSIPRT( Mandator ADD DSTPOR Destinatio TSCROS BSC6900 TNO n port No. S(Mandat ory)

None

IP Address Type

None

Subnet mask of BTS Route.

GBFD118601

IP Abis over Address IP Type

None

Destinatio n of None timeslot cross

None

Interval Type

0~335

ADD Destinatio Target DSTTSM TSCROS n timeslot BSC6900 timeslot ASK S(Mandat mask mask ory)

None

None

Bit Field Type

Threshold of the load in the target cell for the directed retry. Only Directed SET a cell Retry DTLOAD GCELLC whose GBFDLoad BSC6900 THRED CBASIC( load is 110607 Access Optional) lower Threshold than or equal to this threshold can be selected as a candicate

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

Direct Retry

Interval Type

0~100

DTRTYP DRX E Type

SET GCELLG BSC6900 SMR(Opti onal)

DTRX

Down Link No.

ADD BTSANTF BSC6900 EEDERB RD(Mand atory)

Type of the DRX supportin g the VGCS service. An MS reads the NCH only when a new notificatio n message of group call arrives. This helps save power of the MS. This parameter is Downlink TRX index number of the newly added board

GBFD510301

Public Voice Group Call Service

Enumerati NO(No), on Type YES(Yes)

GBFD111202

O&M of BTS

Interval Type

1~12

DTRX

Down Link No.

SET BTSANTF BSC6900 EEDERC ONNECT( Optional)

Index number of GBFDthe 111202 downlink tributary

O&M of BTS

1(1), 2(2), 3(3), 4(4), 5(5), 6(6), Enumerati 7(7), 8(8), on Type 9(9), 10(10), 11(11), 12(12)

TRX board ADD Down pass BTSANTF TRX GBFDnumber DTRXPN BSC6900 EEDERB Board connecte 111202 RD(Optio Pass No. d with the nal) downlink tributary TRX board SET Down pass BTSANTF TRX GBFDnumber DTRXPN BSC6900 EEDERC Board connecte 111202 ONNECT( Pass No. d with the Optional) downlink tributary

O&M of BTS

Interval Type

0~1

O&M of BTS

Interval Type

0~1,255

Number of the slot where the ADD TRX Down BTSANTF board that GBFDDTRXSN TRX Slot BSC6900 EEDERB connects 111202 No. RD(Mand to atory) downlink tributary is located Number SET Down BTSANTF DTRXSN TRX Slot BSC6900 EEDERC No. ONNECT( Optional) of the slot where the TRX board that GBFDconnects 111202 to downlink tributary is located Number

O&M of BTS

Interval Type

0~23

O&M of BTS

Interval Type

0~23,255

Down DTRXSR TRX N Subrack No.

of the subrack ADD where the BTSANTF TRX GBFDBSC6900 EEDERB board that 111202 RD(Mand connects atory) to downlink tributary is located Number of the subrack where the TRX GBFDboard that 111202 connects to downlink tributary is located

O&M of BTS

Interval Type

0~53

Down DTRXSR TRX N Subrack No.

SET BTSANTF BSC6900 EEDERC ONNECT( Optional)

O&M of BTS

Interval Type

0~53,255

Whether a BTS randomiz es the dummy bits in all the signaling message Dummy SET s that the DUMMYB Bit GCELLS BTS ITRANDS Randomiz BSC6900 OFT(Opti sends to WITCH ation onal) an MS. Switch That is, dummy bits are randomiz ed rather than filled on the basis of 0x2B. The duplex SET mode of Duplex BTSETH DUPLEX BSC6900 FE port is Mode PORT(Op duplex or tional) halfduplex. Duration STR for Duration< BTSTST( DURATH BSC6900 starting Hour> Mandator the BTS y) test Duration for STR starting TRXBUR BSC6900 the TRX STTST(M idle andatory) timeslot test

GBFD113521

A5/1 Encryptio Enumerati OFF(Off), n Flow on Type ON(On) Optimizati on

GBFD118601

FULL(FU Abis over Enumerati LL), IP on Type HALF(HA LF)

GBFD111207

BTS Test Interval Function Type

0~12

DURATH

Duration Hour

GBFD111207

BTS Test Interval Function Type

1~24

Duration STR for Duration< BTSTST( DURATM BSC6900 starting minute> Mandator the BTS y) test Duration for STR starting Duration< BTSTST( DURATS BSC6900 the TRX s> Mandator idle y) timeslot test

GBFD111207

BTS Test Interval Function Type

0~59

GBFD111207

BTS Test Interval Function Type

0~59

Downlink Multiplex Threshold DWNDYN of CHNTRA Dynamic NLEV Channel Conversio n

DL Signal DWNINT Strength EN Limit

Downlink multiplex threshold of dynamic channel conversio n. When the subscribe r number on the channel reaches the value SET (threshold GCELLP /10), the BSC6900 SCHM(O dynamic ptional) channel conversio n is triggered. We recomma nd that the value of "Downlink Multiplex Threshold of Dynamic Channel Conversio An MS can be used to test the Um interface software synchroni zation only when ADD the DL BSC6900 AISSCFG signal (Optional) strength after the power control compens ation in the test cell and the observed cell is

GBFD114101 GBFD113101 GBFD119303 GBFD119501 GBFD114101 GBFD113101 GBFD119303 GBFD119501

GPRS PDCH Dynamic Adjustme nt Load Sharing Adaptive Adjustme nt of Uplink and Downlink Channels Interval GPRS Type PDCH Dynamic Adjustme nt Load Sharing Adaptive Adjustme nt of Uplink and Downlink Channels

10~80

GBFD118201

SoftSynchroni Interval zed Type Network

0~63

DXXINDE Up DXX X Index

DXXINDE DXX X Index

Number of a DXX. It is ADD unique in BTSCON one GBFDBSC6900 NECT(Ma BSC6900 111202 ndatory) and uniquely identifies a DXX. ADD DXX(Man Number datory) of a DXX. ADD It is DXXCON unique in NECT(Ma one GBFDBSC6900 ndatory) BSC6900 111203 ADD and DXXTSE uniquely XGRELA identifies TION(Ma a DXX. ndatory)

O&M of BTS

Interval Type

0~2047

O&M of BSC

Interval Type

0~2047

DXXPN

Up DXX Port No.

ADD BTSCON BSC6900 NECT(Ma ndatory)

Number of the GBFDupper 111202 DXX port

O&M of BTS

Interval Type

0~15

Time to wait for releasing the dynamic channel after the TBF on the dynamic channel is released. When all the TBFs on the Timer of SET channel Releasing DYNCHF GCELLP are GBFDIdle BSC6900 REETM SCHM(O released, 113101 Dynamic ptional) the Channel dynamic channel is not released at once. Instead, the timer is started when the channels are idle. Before the timer expires, if new

PDCH Dynamic Interval Adjustme Type nt

10~3600

Mode of preemptin g the dynamic channel for the CS domain and PS domain. Only the channel configure d in the TCH/F mode can Level of SET be DYNCHN Preemptin GCELLP preempte PREEMP g BSC6900 SCHM(O d. TLEV Dynamic ptional) "Preempt Channel all dynamic TCHFs" indicates the circuit domain can preempt all the dynamic channels. "No preempt of CCHs" indicates Number of full-rate TCHs reserved for the CS Reservati domain. on This Threshold SET parameter DYNCHT of GCELLP is valid RANRES BSC6900 Dynamic SCHM(O only when LEV Channel ptional) "Level of Conversio Preemptin n g Dynamic Channel" is set to LEVEL1 or

GBFD114101 GBFD113101 GBFD119303 GBFD119501 GBFD114101 GBFD113101 GBFD119303 GBFD119501

GPRS PDCH Dynamic Adjustme nt Load Sharing Adaptive LEVEL0( Adjustme Preempt nt of all Uplink dynamic and TCHFs), Downlink LEVEL1( Channels Enumerati No GPRS on Type preempt PDCH of CCHs), Dynamic LEVEL2( Adjustme No nt preempt Load of service Sharing TCHF) Adaptive Adjustme nt of Uplink and Downlink Channels

GBFD114101 GBFD113101 GBFD114101 GBFD113101

GPRS PDCH Dynamic Adjustme nt Interval GPRS Type PDCH Dynamic Adjustme nt

0~8

This parameter specifies whether SET to allow Allow GCELLB the DYNOpen Dynamic GBFDBSC6900 ASICPAR BSC6900 TrxPower Shutdown 111602 A(Optiona to enable of TRX l) the TRX Intelligent Shutdown feature on a cell. Whether to enable the cell to Dynamic SET support DYNPBT Transmis GCELLC dynamic GBFDSUPPOR sion Div BSC6900 HMGBASI transmit 118101 TED Supporte C(Optiona diversity d l) or dynamic PBT STR TRANSP BSC6900 ERFTST( Mandator y) Duration for the GBFDtest in E1 111202 mode Number of the E1 port. For the BTS3012, BTS3012 AE, BTS3012 II and the UTRP board in SingleRA N BTSs, the number can be a value from 0 to 7. For other BTSs, the number can be a value Number of the E1 port on the BTS connecte d to the BSC.

TRX Power Enumerati NO(No), Amplifier on Type YES(Yes) Intelligent Shutdown

Dynamic Transmit Diversity

NOTSUP PORT(No t Support), Enumerati DDIVERS on Type ITY(DDIV ERSITY), DPBT(DP BT)

E1DURA Duration T

O&M of BTS

Interval Type

1~60

E1PORT Port No.

STR TRANSP BSC6900 ERFTST( Mandator y)

GBFD111202

O&M of BTS

Interval Type

0~7

E1 Port E1PORT No NOINBTS Connect CONBSC To BSC

ADD BTSABIS BSC6900 HDLCPA TH(Mand atory)

GBFD118401

Abis Transmis Interval sion Type Optimizati on

0~31

STR Transmis Type of TRANSP E1SLCTT sion the GBFDBSC6900 ERFTST( MU Board transmissi 111207 Mandator Type on board y)

ACTIVE( ACTIVE TMU/MM U/IOMU/ DOMU), ACTIVES TANDBY( ACTIVE/S TANDBY BTS Test Enumerati TMU), Function on Type SLAVE1( SLAVE TMU1/DO MU1), SLAVE2( SLAVE TMU2/DO MU2), UTRP(UT RP)

E1T1PN

E1/T1 port No.

SET E1/T1 COPTLN BSC6900 port K(Optiona number l)

None

None

Interval Type

0~83

E1T1PN

E1/T1 Port No.

Number of the E1/T1 port from which the BTS extracts SET the BTSCLK( transport MRFDBSC6900 Mandator clock. 210501 y) This parameter is valid only when the clock type is set to IP_TRAN

BTS/Nod Interval eB Clock Type

0~7

Number of the port extended by the backboar d TOP communi cation mechanis m of the BTS. The TOP relation can be configure ADD d Backboar BTSTOP E1T1POR between MRFDd E1/T1 BSC6900 CONFIG( TNO 211501 the port Port No. Mandator on the y) BTS board panel and the port on the BTS backplane , thus extending the ports. This function is used for the configurat Type of the E1/T1 from which the BTS extracts the SET transport BTSCLK( MRFDBSC6900 clock. Mandator 210501 This y) parameter is valid only when the clock type is set to IP_TRAN

IP-Based 2G/3G CoTransmis Interval sion on Type Base Station Side

16~19

E1T1TYP E1/T1 E Type

BTS/Nod Enumerati E1(E1), eB Clock on Type T1(T1)

ECHOIP

Peer IP address to be checked. The input address (CHKIPA DDR) must be the address (regardles s of the ADD network Check IP IPPATH( GBFDBSC6900 segment address Mandator 118605 address y) or host address of the peer address) in the network segment specified by the (PEERIP ADDR, PEERMA

IP QOS

IP Address Type

None

ECNOOF Ec/No F Offset

ADD G3GNCE BSC6900 LL(Option al)

Ec/No ADD Threshold ECNOTH GEXT3G for Layer BSC6900 RES CELL(Opt Of 3G ional) Cell

As a performa nce counter for 3G cells, Ec/No indicates the ratio of the energy per received chip to the spectral noise power density. If the Ec/No of a 3G neighbor cell is greater than "HOECN OTH3G" plus this parameter , the neighbor cell is listed in Threshold for determini ng the layer of the 3G neighbor cell. If the Ec/No of the 3G neighbor cell is less than this threshold, the neighbor cell is set to the lowest layer (layer 5).

GBFD114301

GSM/WC DMA Interval Interopera Type bility

0~49

GBFD114301

GSM/WC DMA Interval Interopera Type bility

0~49

ECSC

ECSN

The early classmark sending control (ECSC) parameter specifies whether the MSs in a cell use early classmark sending. After a successfu SET l GCELLC immediat GBFDECSC BSC6900 CBASIC( e 111101 Optional) assignme nt, the MS sends additional classmark informatio n to the network as early as possible. The additional classmark informatio n mainly EXP ALMLOG( End serial End Optional) number of MRFDBSC6900 Serial No. STA the alarm 210304 ALMLOG( record Optional) Date ADD when the GBFDEnd Date BSC6900 SUBTSK( scheduled 111203 Optional) task is stopped End date of the alarm EXP record. By MRFDEnd Date BSC6900 ALMLOG( default, 210304 Optional) the end date is 2037-1231.

System Enumerati NO(No), Informatio on Type YES(Yes) n Sending

Faulty Interval Managem Type ent

1~214748 3646

ED

O&M of BSC

year, Compoun month, d Type date

ED

Faulty year, Compoun Managem month, d Type ent day

ED

End date of the alarm STA record. By MRFDEnd Date BSC6900 ALMLOG( default, 210304 Optional) the end date is 2037-1231. STR GBFDEnd Date BSC6900 BTSLOG( End date 111202 Optional)

Faulty year, Compoun Managem month, d Type ent day

EDATE

O&M of BTS

year, Compoun month, d Type day

EDAY

End date SET of the End date BSC6900 TZ(Mand daylight atory) saving time

GBFD116101 MRFD210301

Support of Daylight Saving Interval Time Type Configura tion Managem ent

1~31

Number SET of GCELLH EDBLAST Satisfacto BSC6900 OEDBPA TIME ry RA(Optio Measure nal) ments

Total Number EDBSTA of TTIME Measure ments

SET GCELLH BSC6900 OEDBPA RA(Optio nal)

According to the P/N rule, if the conditions for the handover between the subcells of an enhanced dualfrequency network are met during P of N measure ments, the handover is triggered. This parameter specifies the According to the P/N rule, if the conditions for the handover between the subcells of an enhanced dualfrequency network are met during P of N measure ments, the handover is triggered. This parameter specifies the

GBFD114402

Enhanced DualInterval Band Type Network

1~255

GBFD114402

Enhanced DualInterval Band Type Network

1~255

Subcell HO EDBSYS Allowed FLOWLE Flow V Control Level

If the current system flow control level is greater than this parameter , the handover between the underlaid and SET overlaid GCELLH subcells GBFDBSC6900 OEDBPA due to low 114402 RA(Optio or high nal) load in the underlaid subcell is not allowed. System flux threshold s correspon d to the system flux obtained Whether the current cell supports EDGE

Enhanced DualInterval Band Type Network

0~11

EDGE

EDGE

SET GCELLG BSC6900 PRS(Opti onal)

GBFD114201

EGPRS

Enumerati NO(No), on Type YES(Yes)

According to the P/N rule, if a neighbor cell meets the conditions for selecting the neighbor cell for edge Edge HO ADD handover EDGEAD AdjCell G2GNCE in P of N GBFDJLASTTI BSC6900 Valid LL(Option measure 510501 ME Time al) ment reports, the edge handover to the neighbor cell is triggered. This parameter specifies the number P.

HUAWEI Interval II Type Handover

1~32

According to the P/N rule, if a neighbor cell meets the conditions for selecting the neighbor cell for edge Edge HO ADD handover EDGEAD AdjCell G2GNCE in P of N GBFDJSTATTI BSC6900 Watch LL(Option measure 510501 ME Time al) ment reports, the edge handover to the neighbor cell is triggered. This parameter specifies the number N.

HUAWEI Interval II Type Handover

1~32

According to the P/N rule, if the conditions for edge handover are met in P of N Handover measure SET Algorithm ment EDGELA GCELLH GBFDII Edge BSC6900 reports, ST OBASIC( 510501 HO Valid the Optional) Time handover is triggered. This parameter specifies the number P.

HUAWEI Interval II Type Handover

1~32

According to the P/N rule, if the conditions for edge handover are met for P Handover seconds SET Algorithm within N EDGELA GCELLH GBFDI Edge BSC6900 seconds, ST1 OBASIC( 110601 HO Valid the Optional) Time handover is triggered. This parameter specifies the number P.

HUAWEI Interval I Type Handover

1~32

According to the P/N rule, if the conditions for edge handover are met in P of N Handover measure Algorithm SET ment EDGEST II Edge GCELLH GBFDBSC6900 reports, AT HO OBASIC( 510501 the Watch Optional) handover Time is triggered. This parameter specifies the number N.

HUAWEI Interval II Type Handover

1~32

According to the P/N rule, if the conditions for edge handover are met for P Handover seconds Algorithm SET within N EDGEST I Edge GCELLH GBFDBSC6900 seconds, AT1 HO OBASIC( 110601 the Watch Optional) handover Time is triggered. This parameter specifies the number N.

HUAWEI Interval I Type Handover

1~32

Effect SET Effect Immediat EFTIMMF BTSLOA GBFDImmediat BSC6900 ely LAG DCTRL(M 111202 ely Flag Flag(reser andatory) ve) Whether to support the 11-bit GBFDEGPRS 119201 access request

O&M of BTS

NO(Effect Later), Enumerati YES(Effe on Type ct Immediat ely)

Support EGPRS1 11BIT 1BITCHA EGPRS NREQ Access

SET GCELLP BSC6900 SBASE(O ptional)

11-Bit EGPRS Access

NO(NO), Enumerati YES(YES on Type )

Whether the SET current EGPRS2 EGPRS2GCELLG BSC6900 cell A A PRS(Opti supports onal) EGPRS2A

GBFD510803 GBFD510804

Uplink EGPRS2A Enumerati NO(No), Downlink on Type YES(Yes) EGPRS2A

EDGE SET EGPRSB 8PSK GCELLN EPLIMIT8 BSC6900 Quality C2PARA( PSK Threshold Optional)

EDGE SET EGPRSB GMSK GCELLN EPLIMIT BSC6900 Quality C2PARA( GMSK Threshold Optional)

Used for EDGE 8PSK transmissi on quality statistics. If MEAN_B EP is less than or equals to this threshold, the transmissi on quality is regarded to be deteriorat ed. MEAN_B EP indicates the average error code rate in one measure Used for EDGE GMSK transmissi on quality statistics. If MEAN_B EP is less than or equals to this threshold, the transmissi on quality is regarded deteriorat ed. MEAN_B EP indicates the average error code rate in one measure

GBFD116201

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~31

GBFD116201

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~31

EM

Type of the end date. "WEEK" indicates that the end date is a weekday. "DATE" indicates that the SET end date EndType BSC6900 TZ(Mand is a atory) month day. "DATEW EEK" indicates the end date is expresse d by a combinati on of weekday and

GBFD116101 MRFD210301

DATE(Inp Support ut with of date), Daylight WEEK(In Saving put with Enumerati Time week), on Type Configura DATEWE tion EK(Input Managem with date ent and week)

Priority level of an emergenc y call. If this parameter is set to 15, the functions of reserving TCHs for emergenc y calls and SET preemptin Priority of EMCPRIL GCELLC g TCHs Emergenc BSC6900 V CAD(Opti are not y Call onal) enabled. If the two functions need to be enabled, set this parameter to a value from 1 to 14. If the value of "Emergen cy Call Preemptio n

GBFD110202 GBFD110521

Emergenc y Call Service (TS12) Interval Guarante Type ed Emergenc y Call

1~15

Whether to verify the centralize d signaling link in the case of the link establish ment. ON: emergenc y verificatio n, that is, Emergenc the ADD EMERGE y verificatio GBFDBSC6900 MTP3LKS NCY verificatio 111804 n is not (Optional) n required. OFF: non emergenc y verificatio n, that is, the verificatio n is required during the establish ment of a signaling link in a link set.

A Interface Protocol Process

Enumerati OFF(OFF on Type ), ON(ON)

EMITTHD

ADD Error emit Error emit BSC6900 MPGRP( None threshold threshold. Optional)

None

ERR_PF M_5E6(O CCUR:5E6), ERR_PF M_1E5(O CCUR:1E5), ERR_PF M_5E5(O Enumerati CCUR:5Eon Type 5), ERR_PF M_1E4(O CCUR:1E4), ERR_PF M_5E4(O CCUR:5E4), ERR_PF M_1E3(O

EMLDSC EML P DSCP

SET BSCABIS BSC6900 PRIMAP( Optional)

EMLPPE Allow N EMLPP

SET GCELLC BSC6900 CBASIC( Optional)

EMLPPP eMLPP RIORITY Priority

SET GCELLG BSC6900 SMR(Opti onal)

Differentia ted service code of the specified Whether to allow the function of enhanced multi-level preceden ce and preemptio n (eMLPP). With the eMLPP function enabled, the network can use different policies such as queuing, preemptio n, or directed retry based on the priorities of different calls when Indicating whether the eMLPP function is enabled in a cell and indicating the eMLPP priority of the cell. From high to low, the priorities are A, B, 0, 1, 2, 3, 4 and No Priority.

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

0~63

GBFD115001

Enhanced Multi Level Preceden Enumerati NO(No), ce and on Type YES(Yes) Preemptio n(EMLPP )

GBFD510307

Group Call EMLPP

NoPriority (No Priority), Priority4( Priority 4), Priority3( Priority3), Priority2( Enumerati Priority 2), on Type Priority1( Priority 1), Priority0( Priority 0), PriorityB( Priority B), PriorityA( Priority A)

SET eMLPP EMLPPP OTHSOF Priority In BSC6900 RIORITY TPARA(O Paging ptional)

EMLPRI

EML Priority

SET BSCABIS BSC6900 PRIMAP( Optional)

EMLSP

EML Service PRI

SET BSCSRV BSC6900 PRI(Optio nal)

EMLVLA NID

EML VlanId

SET BSCABIS BSC6900 PRIMAP( Optional)

Whether to include the eMLPP Priority informatio n element in the Paging Comman d message over the Abis interface when "Allow eMLPP" is set to YES and the eMLPP flag in the Bitmap informatio n element of the Paging Service priority of the specified EML Service priority of the extension maintena nce link (EML).0 is the highest priority. Specified EML Vlan Id

GBFD115001

Enhanced Multi Level Preceden Enumerati NO(No), ce and on Type YES(Yes) Preemptio n(EMLPP )

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

0~7

GBFD118605

IP QOS

Interval Type

0~7

GBFD111202

O&M of BTS

Interval Type

2~4094

End EMONTH month

GBFDSET Month on 116101 BSC6900 TZ(Mand which MRFDatory) DST ends 210301

JAN(Janu ary), FEB(Febr uary), MAR(Mar ch), APR(April Support ), of MAY(May Daylight ), Saving Enumerati JUN(June Time on Type ), Configura JUL(July), tion AUG(Aug Managem ust), ent SEP(Sept ember), OCT(Octo ber), NOV(Nov ember), DEC(Dec

EMSIP

EMS IP Address

IP address ADD of the NE GBFDBSC6900 EMSIP(M managem 111202 andatory) ent system

O&M of BTS

IP Address Type

None

ENABLE

Fallback Function Enable

Whether to enable SET the BTSFALL GBFDBSC6900 fallback BACK(Op 510309 function tional) for the BTS

Group Call Enumerati NO(No), Reliability on Type YES(Yes) Enhancin g

ENABLE D

TMA Power Supply Enabled

Whether SET to enable BTSTMA( GBFDBSC6900 the power Mandator 111202 supply of y) the TMA

O&M of BTS

ENABLE D(Enable Enumerati d), on Type DISABLE D(Disable d)

ENCRY

Encryptio SET n Encryptio GCELLB algorithm n BSC6900 ASICPAR supported Algorithm A(Optiona by the l) BSS side

GBFD113501 GBFD113503

A5/1 and A5/2 Ciphering Bit Field Algorithm Type A5/3 Ciphering Algorithm

A5/0~0 A5/1~1 A5/2~2 A5/3~3 A5/4~4 A5/5~5 A5/6~6 A5/7

Encryptio n mode used when the NE serves as the FTP client AUTO: indicating that the FTP client automatic ally selects SET Transport the ENCRYM FTPSSR GBFDEncrypted BSC6900 encryptio ODE V(Optiona 111203 Mode n mode l) PLAINTE XT: indicating that the plain text mode is used forcibly. ENCRYP TED: indicating that the encrypted mode is used

O&M of BSC

AUTO(Au tomatic), PLAINTE XT(Plain Enumerati Text), on Type ENCRYP TED(SSL Encrypted )

The SET ENCRYM Encrypted BSC6900 FTPSCLT ODE Mode (Optional)

Support SET End2End End-toOTHSOF TraceStat end User BSC6900 TPARA(O e Tracing ptional) Function

Encryptio n mode supported when the NE serves as the FTP server AUTO: indicating that the FTP client automatic ally selects the encryptio GBFDn mode 111203 PLAINTE XT: indicating that the plain text mode is used forcibly. ENCRYP TED: indicating that the encrypted mode is used forcibly. Whether to enable end-toend user tracing for the BSC. If this parameter is set to YES, the BSC starts endGBFDto-end 116401 user tracing after the BSC receives the MSC Invoke Trace or BSS Invoke Trace message from the

O&M of BSC

AUTO(Au to), PLAINTE Enumerati XT(Plain on Type Text), ENCRYP TED(SSL Encrypte)

End-toEnd MS Enumerati NO(No), Signaling on Type YES(Yes) Tracing

ENDAID

End Alarm ID

EXP ALMLOG( Optional) BSC6900 STA ALMLOG( Optional)

End number of MRFDthe alarm 210304 record

Faulty Interval Managem Type ent

1~65535

ENDCIC

End CIC

ENDCIC

End CIC

It indicates the end CIC of the A interface CIC segment. When operation mode is BLK set to BSC6900 ACIC(Ma OPC ndatory) index, DPC group index, BSC ID, or CIC, the parameter is mandator y. It indicates the end CIC of the Pb interface CIC segment. BLK If the BSC6900 PBCIC(M search andatory) object mode is set to search by the specified range, the parameter is

GBFD111803

A Interface Interval Circuit Type Managem ent

0~65535

GBFD111203

O&M of BSC

Interval Type

0~65535

Prohibit EndDayD Power STPA Saving End Day

This parameter specifies the end ADD date of a BSCDST period GBFDBSC6900 PADATE( during 111602 Mandator which the y) TRX Intelligent Shutdown feature is disabled.

TRX Power Interval Amplifier Type Intelligent Shutdown

1~31

If the ambient temperatu re reaches the value of this parameter , the heater is shut down. Heater SET In multiENDHEA Shutdown BTSDHE mode GBFDBSC6900 TTEMP Temperat UBP(Opti scenario, 111202 ure onal) the value of this parameter in one mode must be the same as the value of the correspon ding parameter

O&M of BTS

Interval Type

-990~400

Prohibit Power EndMonth Saving DSTPA End Month

This parameter specifies the end ADD month of BSCDST a period GBFDBSC6900 PADATE( during 111602 Mandator which the y) TRX Intelligent Shutdown feature is disabled.

JAN(Jan.) , FEB(Feb. ), MAR(Mar. ), TRX APR(Apr.) Power Enumerati , Amplifier on Type MAY(May Intelligent ), Shutdown JUN(Jun.) , JUL(Jul.), AUG(Aug. ), SEP(Sep)

End Sub ENDSUB Timeslot TS NO.

SET BTSFOR BSC6900 BIDTS(O ptional)

Number of the end GBFDsub111202 timeslot

O&M of BTS

Enumerati 0(0), 2(2), on Type 4(4), 6(6)

This parameter specifies the time Time SET for EndTime When the BSCDST dynamical GBFDTACloseT Function BSC6900 PA(Optio ly 111602 rxPA Is nal) disabling Disabled the TRX Intelligent Shutdown feature

TRX Power Compoun Amplifier hour, min d Type Intelligent Shutdown

ENDTS

End TS

It indicates BLK the end ATERE1T CIC of the GBFDBSC6900 1(Mandat Ater 111801 ory) interface CIC segment.

Ater Interface Interval 4:1 Type Multiplexi ng

8~255

ENDTS

End TS

It indicates the end CIC of the A interface CIC segment. When BLK Operation GBFDBSC6900 AE1T1(M mode is 111803 andatory) set to subrack No., slot No., port No., or CIC, the parameter is mandator y.

A Interface Interval Circuit Type Managem ent

1~31

ENDTS

End Timeslot NO.

SET Number BTSFOR GBFDBSC6900 of the end BIDTS(M 111202 timeslot andatory) Status of the scheduled task. This SET parameter SCHTSK GBFDBSC6900 determine SW(Mand 111203 s whether atory) to start the scheduled task. Status of ADD the GBFDBSC6900 SUBTSK( scheduled 111203 Optional) subtask to be added

O&M of BTS

Interval Type

1~31

ENF

Status

O&M of BSC

DISABLE D(Prohibit Enumerati to Use), on Type ENABLE D(Availabl e)

ENF

Subtask Status

O&M of BSC

DISABLE D(Prohibit Enumerati to Use), on Type ENABLE D(Availabl e)

En Iuo SET ENGOVE Out Cell GCELLH RLDTHR General BSC6900 OIUO(Opt SH OverLoad ional) Thred

ENGSMP SDLMAC FLOWCT RL

SET User GCELLP Plane DL BSC6900 SOTHER Flow Ctrl PARA(Op Switch tional)

If the load of the underlaid subcell is greater than this threshold, certain calls in the underlaid subcell are handed over to the overlaid subcell to balance the traffic between the overlaid Whether to support PS downlink MAC back pressures in GSM. When the buffer is overflowe d, the L2 transmissi on rate is limited if "User Plane DL Flow Ctrl Switch" is "ON". Thus, the data blocks are not lost. If "User Plane DL Flow Ctrl Switch" is "OFF", the L2 transmissi on rate is not limited. In

GBFD113201

Concentri Interval c Cell Type

0~100

MRFD211503

2G/3G CoTransmis sion Resource Enumerati OFF(OFF s on Type ), ON(ON) Managem ent on MBSC

ENIUO

Whether to enable the enhanced concentric cell algorithm in a concentric cell. If a cell supports the enhanced concentric cell Enhanced ADD function, GBFDConcentri BSC6900 GCELL(M when an 113201 c Allowed andatory) overlaidtounderlaid handover or an underlaidtooverlaid handover is decided, the MS compares the receive level

Concentri Enumerati OFF(Off), c Cell on Type ON(On)

If all the calls in the overlaid subcell are handed over to the underlaid subcell when the channel seizure ratio of Load SET the ENLDHO Classificat GCELLH underlaid GBFDBSC6900 PRD ion HO OIUO(Opt subcell is 113201 Period ional) less than "En Iuo Out Cell Low Load Thred", the BSC load increases sharply. In this case, the target subcell may be congeste d and

Concentri Interval c Cell Type

1~255

Signal level step for the hierarchic al loadLoad SET based ENLDHO Classificat GCELLH GBFDBSC6900 handover STP ion HO OIUO(Opt 113201 from the Step ional) overlaid subcell to the underlaid subcell

Concentri Interval c Cell Type

0~63

If the load of the underlaid subcell is less than this threshold, certain calls in the overlaid En Iuo SET subcell ENLOWL Out Cell GCELLH are GBFDBSC6900 DTHRSH Low Load OIUO(Opt handed 113201 Thred ional) over to the underlaid subcell to balance the traffic between the overlaid and underlaid subcells.

Concentri Interval c Cell Type

0~100

Transmis SET ENPREE sion BSCBASI MPTTRA Resource BSC6900 C(Optiona NSADMT Preemptin l) g Support

Transmis SET ENQUET sion BSCBASI RANSAD Resource BSC6900 C(Optiona MT Queuing l) Support

When this parameter is set to "ON", if there are no available Abis transmissi on resources , a highpriority user can preempt the transmissi on resources of a lowpriority user. If the preemptio n succeeds, a call drop occurs at the lowWhen this parameter is set to "ON", if there are no available Abis transmissi on resources , the BSC6900 starts the queuing procedure for the services to wait for available transmissi on resources .

GBFD118605

IP QOS

Enumerati OFF(Off), on Type ON(On)

GBFD118605

IP QOS

Enumerati OFF(Off), on Type ON(On)

If the load of the underlaid subcell is greater than this threshold, the period of the loadbased handover from the underlaid subcell to En Iuo SET the ENSOVE Out Cell GCELLH overlaid GBFDRLDTHR Serious BSC6900 OIUO(Opt subcell, 113201 SH OverLoad ional) "UL Thred Subcell Load Hierarchic al HO Periods", is decrease d by "MOD Step LEN of UL Load HO Period" every second to

Concentri Interval c Cell Type

0~100

Whether to enable the cell to centralize two busy half rate TCHs in different timeslots into one timeslot SET through Enhanced ENTCHA GCELLC handover TCH GBFDDJALLO BSC6900 HMGBASI and then Adjust 113402 W C(Optiona to Allowed l) combine the two idle half rate TCHs in the other timeslot into one full rate TCH dynamical ly

Dynamic Adjustme nt Enumerati NO(No), Between on Type YES(Yes) FR and HR

Type of the M3UA local entity. For details about the ASP and IPSP, see RFC4666. M3UA_A SP: suggeste d to use when there is a signaling ADD Local transfer ENTITYT BSC6900 M3LE(Ma entity type point ndatory) (STP) between the local entity and the destinatio n entity M3UA_IP SP: suggeste d to use when there is no signaling transfer

GBFD118602 GBFD118622

M3UA_A SP(M3UA A over IP Enumerati _ASP), A IP over on Type M3UA_IP E1/T1 SP(M3UA _IPSP)

Type of the destinatio n entity. For details, see RFC4666. M3UA_A SP: suggeste d to use when there is a signaling transfer Destinatio ADD GBFDpoint ENTITYT n entity BSC6900 M3DE(Ma 118602 (STP) type ndatory) between the local entity and the destinatio n entity M3UA_IP SP: suggeste d to use when there is no signaling transfer point

M3UA_S GP(M3UA SGP), M3UA_IP SP(M3UA IPSP), Enumerati A over IP M3UA_S on Type S7SP(M3 UA SS7SP), M3UA_S P(M3UA SP)

Initial signal level used to compute the handover zone for an MS during the SET hierarchic ENUTOO IniLev for GCELLH al loadGBFDLOADINIL EnUtoO BSC6900 OIUO(Opt based 113201 EV Load HO ional) handover from the underlaid subcell to the overlaid subcell of the enhanced concentric cell

Concentri Interval c Cell Type

0~63

EPLCSwit EPLC ch Switch

Whether to enable the enhanced SET packet GBFDBSC6900 TCPARA( loss 115704 Optional) concealm ent (EPLC) function

Enhance ment Packet Enumerati OFF(Off), Loss on Type ON(On) Concealm ent(EPLC )

ERCODE

Return Code

EXP BSC6900 LOG(Opti onal)

SET Emergent ERGCAL GCELLC Call BSC6900 LDIS CBASIC( Disable Optional)

Return code of the command . If this parameter is specified, only the correspon ding record is displayed. If this parameter is not specified, the return code is not considere Whether to disable emergenc y calls. For the MSs of access levels 0 to 9, if the value of this parameter is NO, emergenc y calls are enabled. For the MSs of access levels 11 to 15, emergenc y calls are disabled only when the relevant access control bit is set to 0 and this parameter is set to YES.

GBFD111203 MRFD210305

O&M of BSC Interval Security Type Managem ent

1~429496 7295

GBFD110202

Emergenc y Call Enumerati NO(No), Service on Type YES(Yes) (TS12)

SET ETHPOR T(Optiona Errorl) ERRALA frame ADD BSC6900 RMTHD alarm PPPLNK( threshold Optional) ADD MPGRP( Optional)

Errorframe GBFDalarm 118630 threshold

Ethernet OAM

O1E3_R5 E4(OCCU R:1E-3, RECOVE RY:5E-4), O5E4_R1 E4(OCCU R:5E-4, RECOVE RY:1E-4), O1E4_R5 E5(OCCU R:1E-4, RECOVE Enumerati RY:5E-5), on Type O5E5_R1 E5(OCCU R:5E-5, RECOVE RY:1E-5), O1E5_R5 E6(OCCU R:1E-5, RECOVE RY:5E-6), O5E6_R1 E6(OCCU R:5E-6, RECOVE RY:1E-6)

ErrorERRDET frame ECTSW detect switch

SET ETHPOR T(Optiona l) ADD BSC6900 PPPLNK( Optional) ADD MPGRP( Optional) SET BSCABIS BSC6900 PRIMAP( Optional)

Errorframe detect switch

GBFD118630

Ethernet OAM

Enumerati OFF(OFF on Type ), ON(ON)

ESLDSC ESL P DSCP

ESLPRI

ESL Priority

Differentia ted service None code of the specified SET Service BSCABIS BSC6900 priority of None PRIMAP( the ESL Optional)

None

Interval Type

0~63

None

Interval Type

0~7

ESLSP

ESL Service PRI

ESLVLAN ESL ID VlanId

Priority of a service running over an extended signaling link (ESL). SET ESLs are BSCSRV GBFDBSC6900 used for PRI(Optio 118605 more nal) reliably transmitti ng important signaling message s.0 is the highest SET Specified BSCABIS GBFDBSC6900 ESL Vlan PRIMAP( 111202 Id Optional)

IP QOS

Interval Type

0~7

O&M of BTS

Interval Type

2~4094

ESSN

End synchroni EXP End Sync zation MRFDBSC6900 ALMLOG( Serial No. number of 210304 Optional) the alarm record Timer for the BSC waiting for an Establish Indication message after sending an Immediat SET e GCELLT GBFDBSC6900 Assignme MR(Optio 110502 nt nal) message. If T3101 expires before the BSC receives an Establish Indication message, the BSS

Faulty Interval Managem Type ent

1~214748 3646

ESTABIN T3101 DTIMER

Assignme nt and Immediat Interval e Type Assignme nt

500~6000 0

Whether to add the TA value to a Add TA to SET complete ESTINDL A AITFOTH layer-3 GBFD3MSGTA BSC6900 Interface PARA(Op message 115403 FLAG EST IND tional) to provide the LCS function on the A interface When the OML is switched to a port where the connectio n is successfu lly establishe d, the switchove r cannot be performe SET d over a BTSRING certain GBFDBSC6900 ATTR(Opt period of 117802 ional) time, which is specified as ring II rotating penalty time. In this manner, frequent switchove r between the ports due to intermitte nt blinking GBFD116101 MRFD210301

Simple CLOSE(C Mode Enumerati lose), LCS(Cell on Type OPEN(Op ID + TA) en)

Ring II Rotating ESTTIME Penalty Time

Fast Ring Interval Network Type Switch

0~255

ET

SET End time EndTime BSC6900 TZ(Mand of DST atory)

Support of Daylight Saving Compoun HOUR, Time d Type MIN, SEC Configura tion Managem ent

ET

ET

The operation time of the log record is prior to EXP this time. End Time BSC6900 LOG(Opti If this onal) parameter is not specified, the end time is not limited. Time when the scheduled subtask is stopped. If the time mode is ADD set to SUBTSK( End Time BSC6900 "DAILY_T Mandator ", y) "WEEKLY _T", or "MONTHL Y_T", you should set this parameter

GBFD111203

O&M of BSC

year, month, Compoun date, d Type hour, min, sec

GBFD111203

O&M of BSC

Compoun hour, min d Type

ET

Execute Type

Execution mode of the command s 1. ONE_BY_ ONE: indicating that the command s are executed one by one RUN according BATCHFI to the GBFDBSC6900 LE(Option execution 111203 al) sequence . Only one command can be executed once. 2. PARALLE L: indicating that multiple command s are executed in parallel. The

O&M of BSC

ONE_BY_ ONE(Exe cute One Enumerati by One), on Type PARALLE L(Parallel Execute)

ET

operation time of the log record is prior to COL this time. End Time BSC6900 LOG(Opti If this onal) parameter is not specified, the end time is not limited. End time

GBFD111203 MRFD210305

O&M of year, BSC month, Compoun Security date, d Type Managem hour, min, ent sec

ET

of the alarm EXP record. By MRFDEnd Time BSC6900 ALMLOG( 210304 default, Optional) the end time is 23:59:59.

Faulty Compoun hour, min, Managem d Type sec ent

ET

STA End Time BSC6900 ALMLOG( Optional)

ET

ADD GSMSCB End Time BSC6900 (Mandator y)

ETD

ADD End Date BSC6900 OP(Mand atory)

End time of the alarm record. By default, the end time is 23:59:59. End date and time of a broadcast message. This is a key parameter for identifying a simple cell broadcast message. You can use "DSP GSMSCB " to query and obtain the value of this parameter End date of the user operation. Input format: YYYY&M M&DD

MRFD210304

Faulty Compoun hour, min, Managem d Type sec ent

GBFD113602

year, Simplified Compoun month, Cell d Type day, hour, Broadcast min, sec

GBFD111203 MRFD210305

O&M of BSC year, Compoun Security month, d Type Managem day ent

ETIME

STR End Time BSC6900 BTSLOG( End time Optional)

GBFD111202

O&M of BTS

Compoun hour, min, d Type sec

ETP

Type of the log to be queried. EXP The result Log Type BSC6900 LOG(Opti is onal) displayed by the specified type.

GBFD111203 MRFD210305

LOGINEV ENT(Logi n Event), MANAGE EVENT(M O&M of anageme BSC nt Event), Enumerati Security AUTHEV on Type Managem ENT(Auth ent entication Event), OTHERE VENT(Ot her Event)

ETT

End time of the user operation. ADD The input End Time BSC6900 OP(Mand format of atory) this parameter is HH&MM& SS.

GBFD111203 MRFD210305

O&M of BSC Compoun hour, min, Security d Type sec Managem ent

EWEEK

GBFDSET Weekday 116101 End week BSC6900 TZ(Mand on which MRFDatory) DST ends 210301

EWSEQ

Sequence SET End week of the end BSC6900 TZ(Mand sequence week of atory) DST

GBFD116101 MRFD210301

SUN(Sun day), MON(Mo Support nday), of TUE(Tues Daylight day), Saving Enumerati WED(We Time on Type dnesday), Configura THU(Thur tion sday), Managem FRI(Frida ent y), SAT(Satu rday) FIRST(Fir Support st), of SECOND Daylight (Second), Saving Enumerati THIRD(Th Time on Type ird), Configura FOURTH( tion Fourth), Managem LAST(Las ent t)

Upper limit of extended output analog signal 1. If "Sensor Type of External Analog 1" Upper is set to Limit of VOLTAG EX_ANO ADD Signal E, the unit MRFD1_SIG_M BSC6900 EMU(Opti Output of of this 210304 AX onal) External parameter Analog 1 is V; if "Sensor Type of External Analog 1" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Lower limit of extended output analog signal 1. If "Sensor Type of External Analog 1" Lower is set to Limit of VOLTAG EX_ANO ADD Signal E, the unit MRFD1_SIG_MI BSC6900 EMU(Opti Output of of this 210304 N onal) External parameter Analog 1 is V; if "Sensor Type of External Analog 1" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Sensor EX_ANO Type of 1_TYPE External Analog 1

Sensor ADD type of MRFDBSC6900 EMU(Opti extended 210304 onal) analog signal 1

VOLTAG E(Voltage Faulty Enumerati ), Managem on Type CURREN ent T(Current )

Maximum measure ment range of extended analog signal 1. If "Sensor Type of External Upper Analog 1" Limit of is set to EX_ANO Measure ADD VOLTAG MRFD1_VAL_M ment BSC6900 EMU(Opti E, the unit 210304 AX Range of onal) of this External parameter Analog 1 is V; if "Sensor Type of External Analog 1" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Minimum measure ment range of extended analog signal 1. If "Sensor Type of External Lower Analog 1" Limit of is set to EX_ANO Measure ADD VOLTAG MRFD1_VAL_M ment BSC6900 EMU(Opti E, the unit 210304 IN Range of onal) of this External parameter Analog 1 is V; if "Sensor Type of External Analog 1" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Upper limit of extended output analog signal 2. If "Sensor Type of External Analog 2" Upper is set to Limit of VOLTAG EX_ANO ADD Signal E, the unit MRFD2_SIG_M BSC6900 EMU(Opti Output of of this 210304 AX onal) External parameter Analog 2 is V; if "Sensor Type of External Analog 2" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Lower limit of extended output analog signal 2. If "Sensor Type of External Analog 2" Lower is set to Limit of VOLTAG EX_ANO ADD Signal E, the unit MRFD2_SIG_MI BSC6900 EMU(Opti Output of of this 210304 N onal) External parameter Analog 2 is V; if "Sensor Type of External Analog 2" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Sensor EX_ANO Type of 2_TYPE External Analog 2

Sensor ADD type of MRFDBSC6900 EMU(Opti extended 210304 onal) analog signal 2

VOLTAG E(Voltage Faulty Enumerati ), Managem on Type CURREN ent T(Current )

Maximum measure ment range of extended analog signal 2. If "Sensor Type of External Upper Analog 2" Limit of is set to EX_ANO Measure ADD VOLTAG MRFD2_VAL_M ment BSC6900 EMU(Opti E, the unit 210304 AX Range of onal) of this External parameter Analog 2 is V; if "Sensor Type of External Analog 2" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Minimum measure ment range of extended analog signal 2. If "Sensor Type of External Lower Analog 2" Limit of is set to EX_ANO Measure ADD VOLTAG MRFD2_VAL_M ment BSC6900 EMU(Opti E, the unit 210304 IN Range of onal) of this External parameter Analog 2 is V; if "Sensor Type of External Analog 2" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Upper limit of extended output analog signal 3. If "Sensor Type of External Analog 3" Upper is set to Limit of VOLTAG EX_ANO ADD Signal E, the unit MRFD3_SIG_M BSC6900 EMU(Opti Output of of this 210304 AX onal) External parameter Analog 3 is V; if "Sensor Type of External Analog 3" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Lower limit of extended output analog signal 3. If "Sensor Type of External Analog 3" Lower is set to Limit of VOLTAG EX_ANO ADD Signal E, the unit MRFD3_SIG_MI BSC6900 EMU(Opti Output of of this 210304 N onal) External parameter Analog 3 is V; if "Sensor Type of External Analog 3" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Sensor EX_ANO Type of 3_TYPE External Analog 3

Sensor ADD type of MRFDBSC6900 EMU(Opti extended 210304 onal) analog signal 3

VOLTAG E(Voltage Faulty Enumerati ), Managem on Type CURREN ent T(Current )

Maximum measure ment range of extended analog signal 3. If "Sensor Type of External Upper Analog 3" Limit of is set to EX_ANO Measure ADD VOLTAG MRFD3_VAL_M ment BSC6900 EMU(Opti E, the unit 210304 AX Range of onal) of this External parameter Analog 3 is V; if "Sensor Type of External Analog 3" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Minimum measure ment range of extended analog signal 3. If "Sensor Type of External Lower Analog 3" Limit of is set to EX_ANO Measure ADD VOLTAG MRFD3_VAL_M ment BSC6900 EMU(Opti E, the unit 210304 IN Range of onal) of this External parameter Analog 3 is V; if "Sensor Type of External Analog 3" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Upper limit of extended output analog signal 4. If "Sensor Type of External Analog 4" Upper is set to Limit of VOLTAG EX_ANO ADD Signal E, the unit MRFD4_SIG_M BSC6900 EMU(Opti Output of of this 210304 AX onal) External parameter Analog 4 is V; if "Sensor Type of External Analog 4" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Lower limit of extended output analog signal 4. If "Sensor Type of External Analog 4" Lower is set to Limit of VOLTAG EX_ANO ADD Signal E, the unit MRFD4_SIG_MI BSC6900 EMU(Opti Output of of this 210304 N onal) External parameter Analog 4 is V; if "Sensor Type of External Analog 4" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Sensor EX_ANO Type of 4_TYPE External Analog 4

Sensor ADD type of MRFDBSC6900 EMU(Opti extended 210304 onal) analog signal 4

VOLTAG E(Voltage Faulty Enumerati ), Managem on Type CURREN ent T(Current )

Maximum measure ment range of extended analog signal 4. If "Sensor Type of External Upper Analog 4" Limit of is set to EX_ANO Measure ADD VOLTAG MRFD4_VAL_M ment BSC6900 EMU(Opti E, the unit 210304 AX Range of onal) of this External parameter Analog 4 is V; if "Sensor Type of External Analog 4" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

Minimum measure ment range of extended analog signal 4. If "Sensor Type of External Lower Analog 4" Limit of is set to EX_ANO Measure ADD VOLTAG MRFD4_VAL_M ment BSC6900 EMU(Opti E, the unit 210304 IN Range of onal) of this External parameter Analog 4 is V; if "Sensor Type of External Analog 4" is set to CURREN T, the unit of this parameter is A.

Faulty String Managem Type ent

None

EXCACC

Exclusive Access

Exception al Frame EXCEPF Threshold RAMETH of Mute RES Detect Class1

Whether it is a SoLSA exclusive access cell. If it is a SoLSA SET exclusive GCELLS access BSC6900 ERVPAR cell, only A(Optiona the MS l) subscribin g the Localised Service Area (LSA) can access this cell. Threshold for the rate of the number of bad frames to the total number of TRAU frames. If the bad frame rate exceeds this threshold SET within the GCELLS "Period of BSC6900 OFT(Opti Mute onal) Detection Class1", mute speech may be detected. The setting of "Mute Detection Class 2 Switch" determine s whether to perform the class-

GBFD114101

GPRS

NoExclusi ve(NoExcl Enumerati usive), on Type Exclusive( Exclusive)

GBFD111203

O&M of BSC

Interval Type

0~100

Received signal strength at an MS expected SET in power Expected GCELLP EXPDLR forecast, GBFDDL BSC6900 WRBASI XLEV which 117602 RX_LEV C(Optiona helps to l) compute the initial transmit power of the BTS

Active Power Control

Interval Type

0~63

Received signal strength at the BTS SET expected Expected GCELLP in power EXPULR GBFDUL BSC6900 WRBASI forecast, XLEV 117602 RX_LEV C(Optiona which l) helps to compute the initial transmit power of an MS

Active Power Control

Interval Type

0~63

ID of the cell. The cell ID cannot conflict with other ADD cell IDs in EXT2GC GEXT2G MRFDCell Index BSC6900 the ELLID CELL(Ma 210301 BSC6900. ndatory) The cells in the BSC are numbered sequential ly.

Configura tion Interval Managem Type ent

2048~504 7

EXT2GC Cell ELLNAM Name E

ADD GEXT2G Name of BSC6900 CELL(Ma the cell ndatory)

GBFD111202

O&M of BTS

String Type

None

ID of the cell. The cell ID cannot conflict ADD with other EXT3GC GEXT3G cell IDs in MRFDCell Index BSC6900 ELLID CELL(Ma the BSC. 210301 ndatory) The cells in the BSC are numbered sequential ly.

Configura tion Interval Managem Type ent

5048~804 7

EXT3GC Cell ELLNAM Name E

ADD GEXT3G Name of BSC6900 CELL(Ma the cell ndatory)

GBFD111202

O&M of BTS

String Type

None

Index of ADD BSC the cell in EXTADJC EXTNCE MRFDAdjacent BSC6900 the ELLID LL(Manda 210301 Cell Index adjacent tory) BSC

Configura tion Interval Managem Type ent

2048~504 7

BSC EXTADJC Adjacent ELLNAM Cell E Name

Name of ADD the cell in EXTNCE MRFDBSC6900 the LL(Manda 210301 adjacent tory) BSC

Configura tion String Managem Type ent

None

Whether to support the downlink throughpu t enhance ment function of the dual timeslot Extended SET cell. Cell GCELLP When this EXTCELL Throughp GBFDBSC6900 SOTHER switch is THRENH ut 114001 PARA(Op turned on, Enhance tional) the ment system can allocate the packet downlink channel of the odd number timeslot of dual timeslot Whether Extended to enable SET Switch of alarm GBFDBSC6900 BTSALM( Input extension 111202 Optional) Alarm input for the BTS

CLOSE(C Extended Enumerati lose), Cell on Type OPEN(Op en)

EXTFlag

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

Whether the network Extension SET requires Measure GCELLE EXTMEA an MS to ment BSC6900 XTMSRP SORD send an Comman ARA(Opti extension d onal) measure ment report

GBFD110801 GBFD110802

Processin g of Measure EM0(EM0 ment Enumerati ), Report on Type EM1(EM1 Pre) processin g of Measure ment

EXTRPT PERIOD

Time interval SET between Extension GCELLE two MR BSC6900 XTMSRP extension Period ARA(Opti measure onal) ment reports

GBFD110801 GBFD110802

60sec(60 sec), 120sec(1 Processin 20sec), g of 240sec(2 Measure 40sec), ment 480sec(4 Report Enumerati 80sec), Preon Type 960sec(9 processin 60sec), g of 1920sec( Measure 1920sec), ment 3840sec( Report 3840sec), 7680sec( 7680sec)

Type of an extension measure ment report. There are three types of extension measure ment reports: type 1, type 2, SET and type GCELLE EXTRPTT Extension 3. BSC6900 XTMSRP YPE MR Type Type 1: ARA(Opti No matter onal) whether the BSIC was decoded, the MS sends the network a measure ment report on the six strongest TRXs. The measure

GBFD110801 GBFD110802

Processin g of Measure TYPE1(T ment YPE1), Report Enumerati TYPE2(T Preon Type YPE2), processin TYPE3(T g of YPE3) Measure ment Report

EXTTP

Whether a cell is an extension cell. A doubletimeslot extension cell regards an Cell ADD additional GBFDExtension BSC6900 GCELL(O TDMA 114001 Type ptional) frame as access delay extension. In theory, the supported TA value is 219, that is, a time delay of about

Normal_c ell(Normal cell), DualTS_E Extended Enumerati xtCell(Do Cell on Type uble Timeslot Extension Cell)

Whether to send the Not Send Dummy Dummy SET message Message EXTUTBF GCELLP during the GBFDwith BSC6900 NODATA SBASE(O deactivate 119203 Extended ptional) d period Uplink of the TBF extended uplink TBF

SEND(SE Extended ND), Enumerati Uplink NOTSEN on Type TBF D(NOTSE ND)

FACCH FACCHR Msg ESENDIN Resend T Interval

Interval of sending a paging message or notificatio n message on the FACCH. Messages on the FACCH are sent in the SET mode of GCELLG speech BSC6900 SMR(Opti frame onal) stealing. A large number of consecuti ve stolen speech frames may affect the voice quality and even lead to no voice. Therefore , the BTS

GBFD510301 GBFD510302

Public Voice Group Call Interval Service Type Public Voice Broadcast Service

0~255

FACCH SET FACCHS Send GCELLG ENDNOT Notificatio BSC6900 SMR(Opti MSGIND n Msg onal) Indication

FACCH SET FACCHS Send GCELLG ENDPGM Paging BSC6900 SMR(Opti SGIND Msg onal) Indication

Whether to allow sending notificatio n message s on the FACCH. If the value of this parameter is YES, an MS engaged in a pointto-point call can receive a notificatio n message for a group call. You can interrupt the existing call and Whether to allow sending paging message s on the FACCH. If the value of this parameter is YES, an MS can receive a paging message on the group call channel. You can leave the group call and respond to the paging

GBFD510307

Group Call EMLPP

Enumerati NO(No), on Type YES(Yes)

GBFD510307

Group Call EMLPP

Enumerati NO(No), on Type YES(Yes)

TRM FACTOR Factor SW switch

SET Activation BSCABIS GBFDBSC6900 factor PRIMAP( 111202 switch Optional) If this parameter is set to ON, the BSC assigns the channels in the TRXs of the cell in a polling manner. Therefore SET , each GCELLC TRX has GBFDBSC6900 HMGBASI an even 111005 C(Optiona chance to l) be used. In this way, the connectio n between the TRX and the RF can be checked without manual dialing tests.

O&M of BTS

Enumerati OFF(OFF on Type ), ON(ON)

FACTOR Factory YMODE Mode

Enhanced Channel Enumerati OFF(Off), Assignme on Type ON(On) nt Algorithm

Penalty FAILSIGS Level TRPUNIS after HO H Fail

Penalty signal level imposed on a target cell to which the handover fails due SET to GCELLH congestio BSC6900 OFITPEN n or poor (Optional) radio quality. This penalty helps to prevent the MS from making a second handover

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

Continuou SET Continuou FANADJ s FANSPE s speed MRFDUSTCOM adjustme BSC6900 ED(Optio adjustme 210301 MAND0 nt nal) nt command

PLUS_1( Current FanSpee Configura d Plus 1), tion Enumerati MINUS_1 Managem on Type (Current ent FanSpee d Minus 1) Configura HIGH_SP tion Enumerati EED, Managem on Type LOW_SP ent EED

Discrete SET FANADJ adjustme FANSPE USTCOM BSC6900 nt ED(Optio MAND1 command nal)

Discrete speed MRFDadjustme 210301 nt

Duty ratioDuty ratio SET FANADJ based adjustme FANSPE MRFDUSTCOM BSC6900 speed nt ED(Optio 210301 MAND2 adjustme command nal) nt

Configura tion Interval Managem Type ent

55~100

SET FANADJ Fan Fan FANSPE MRFDUSTMOD adjustme BSC6900 adjustme ED(Optio 210301 E nt mode nt mode nal)

CONTINU OUS(Con tinuous), Configura DISCRET tion Enumerati E(Discret Managem on Type e), ent DUTY_R ATIO(Dut y Ratio)

FANFLA G

SET FANSPE Type of Fan Type BSC6900 ED(Mand the fan atory)

MRFD210301

NORMAL Configura _FAN(Nor tion Enumerati mal Fan), Managem on Type IND_FAN ent (Independ ent Fan) NO_SPE ED_ADJU STMENT( No Speed Adjustme nt), HW_AUT O_TEMP ERATUR Configura E_CONT tion Enumerati ROL(Auto Managem on Type Temperat ent ure Control), SPECIFY _RATE(S pecify Rate), SOFTWA RE_CON TROL(Sof IND_FAN Configura (Independ tion Enumerati ent Fan), Managem on Type NORMAL ent _FAN(Nor mal Fan)

SET Speed Fan FANSPE FANSPE MRFDadjustme BSC6900 adjustme EDMODE ED(Mand 210301 nt mode nt mode atory)

FANTYPE

FanBox Type

LOD Type of BSC6900 FAN(Man the fan datory) box

MRFD210301

After a channel request message is received, the type of the channel needs to be specified. In this case, if the Fast Call SET FASTCAL threshold Setup GCELLB LTCHTH GBFDof the TCH BSC6900 ASICPAR RESHOL 110502 load on Usage A(Optiona D the TCH Threshold l) in the current cell is smaller than the Fast Call Setup TCH Usage Threshold and the request message is not issued

Assignme nt and Immediat Interval e Type Assignme nt

0~100

Ring II function switch. The SET parameter FASTCN Configure BTSRING should be GBFDBSC6900 ETFLAG Ring II ATTR(Opt set to 117802 ional) "YES" when the ring II function is enabled.

Fast Ring Enumerati NO(No), Network on Type YES(Yes) Switch

Fault FaultDete Detect ctSwitch Switch

SET BSC6900 TCPARA( Optional)

FC

Physical SET layer flow ETHPOR BSC6900 control T(Optiona switch l)

Whether to enable the memory GBFDself-check 111203 and selfhealing function Whether to send and process the flow control frame on the physical layer. The None setting of this parameter must be negotiate d with that on the interconn ected

O&M of BSC

Enumerati OFF(Off), on Type ON(On)

None

Enumerati OFF(OFF on Type ), ON(ON)

If the parameter is set to "YES", it indicates that some data packets are discarded to ensure SET the basic Flow BTSETH functions FC BSC6900 Control PORT(Op of the tional) BTS are not affected when the FE port is overloade d. After the port is not overloade d, the flow control is Threshold for stopping RSL flow control. If the occupanc Flow SET y of the Control FCETHD BSC6900 GTRXFC( LAPD End Optional) queue is Threshold less than this threshold, the BSC6900 stops flow control.

GBFD118601

CLOSE(C Abis over Enumerati lose), IP on Type OPEN(Op en)

GBFD111705

GSM Flow Control

Interval Type

0~100

Flow SET Flow control ETHPOR control FCINDEX BSC6900 None parameter T(Mandat parameter index ory) index

None

Interval Type

0~1999

Flow Flow ADD control control FCINDEX BSC6900 PPPLNK( None parameter parameter Optional) index index

None

Interval Type

0~1999

Flow Flow ADD control control FCINDEX BSC6900 MPGRP( parameter parameter Optional) index index

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

0~1999

Flow ADD Flow control IPLOGIC control FCINDEX BSC6900 None parameter PORT(Op parameter index tional) index

None

Interval Type

0~1999

ADD Flow Flow PORTFL control control FCINDEX BSC6900 OWCTRL None parameter parameter PARA(Ma index index ndatory)

None

Interval Type

10~1999

Flow Flow ADD control control MRFDFCINDEX BSC6900 ETHTRK( parameter parameter 211503 Optional) index index SET Flow Flow BSCABIS control control FCINDEX BSC6900 PRIMAP( None parameter parameter Mandator index index y)

2G/3G CoTransmis sion Resource Interval Type s Managem ent on MBSC None Interval Type

0~1999

2~1999

FCN

Cabinet No. of Parent BTS

ADD BTSAUT BSC6900 OPLAN(M andatory)

Cabinet No. of the GBFDparent 510701 BTS

Compact BTS Automatic Interval Configura Type tion and Planning

0~62

FCN

Cabinet No. of Father BTS

Cabinet ADD No. for BTSCON GBFDBSC6900 the port of NECT(Op 111202 the father tional) BTS

O&M of BTS

Interval Type

0~62

Threshold for starting RSL flow control. If the occupanc Flow SET y of the Control GBFDFCSTHD BSC6900 GTRXFC( LAPD Start 111705 Optional) queue is Threshold greater than this threshold, the BSC6900 starts flow control. CRC ADD verificatio MRFDBSC6900 PPPLNK( n mode of 210103 Optional) PPP link.

GSM Flow Control

Interval Type

0~100

CRC FCSTYPE check mode

None(Non e), Link Enumerati 16bit(16bi aggregati on Type t), on 32bit(32bi t) None(Non e), Enumerati 16bit(16bi on Type t), 32bit(32bi t)

CRC FCSTYPE check mode

CRC ADD verificatio GBFDBSC6900 MPLNK(O n mode of 111202 ptional) MP link.

O&M of BTS

FCSW

Flow control switch

Flow control switch. Other SET switches GBFDBSC6900 FCSW(M are valid 111705 andatory) only when "Flow control switch" is "ON".

GSM Flow Control

Enumerati ON, OFF on Type

FCV

Float charging voltage. Float charging compens ates the discharge d capacity of the battery so that the battery can be charged SET to full FloatBTSAPM voltage GBFDCharging BSC6900 UBP(Opti indefinitel 111202 Voltage onal) y. The value of this parameter is slightly lower than the even charging voltage. See the vendor specificati on for the setting of this

O&M of BTS

Interval Type

432~575

Input mode of the BA lists. AUTO: In this mode, the system fills in the BA1 and BA2 lists according to neighbori ng SET relations GCELLID FDDBA1T FDDBA1 GBFDof cells. BSC6900 LEFDDB AG Input Tag MANU: In 114301 A1(Mand this atory) mode, you can maintain the BA tables by yourself. If the neighbori ng relations of cells are changed, for example, This parameter indicate whether to generate the FDD SET BA2 table GCELLH FDDBA2T FDDBA2 automatic MRFDBSC6900 OFDDBA AG Input Tag 210301 ally 2(Mandat according ory) to neighbor cell relations or to input the FDD BA2 table

GSM/WC AUTO(Au DMA Enumerati to), Interopera on Type MANU(M bility anu)

Configura AUTO(Au tion Enumerati to), Managem on Type MANU(M ent anu)

Offset of a FDD cell report. When the priority of a 3G cell is sequence d, the value of this parameter SET be added FDD GCELLC to the FDDCELL GBFDReporting BSC6900 CUTRAN receive OFF 114301 Offset SYS(Opti level of onal) the 3G cell in the measure ment report. The values of this parameter correspon d to the following decibel values:

GSM/WC DMA Interval Interopera Type bility

0~7

SET FDD GCELLC FDDCELL Reporting BSC6900 CUTRAN THRED Threshold SYS(Opti onal)

SET GCELLID FDDDIVE Diversity BSC6900 LEFDDB RSITY Indication A1(Mand atory)

Threshold of a FDD cell report. When the receive level value in the measure ment report of a 3G cell exceeds the value of this parameter , the measure ment report takes effect. After the valid measure ment report is filtered, the 3G cell joins the cell priority sequence Diversity indication of a 3G cell. This parameter indicates whether the transmit diversity mode on the common channel in a cell is activated. 0 means No,1 means Yes.

GBFD114301

GSM/WC DMA Interval Interopera Type bility

0~7

GBFD114301

GSM/WC DMA Interval Interopera Type bility

0~1

Downlink frequency number that an MS in the connecte d mode retrieves from the 3G neighbori ng cell SET list. The Downlink GCELLID FDDDLU numbers GBFDFrequenc BSC6900 LEFDDB ARFAN are sent 114301 y A1(Mand through atory) system message 2QUATE R/MI. The value ranges of frequency numbers vary with correspon ding band reporting. Minimum PS FDD ADD FDDECQ Ec/No of Ec/No GEXT3G GBFDUALTHR BSC6900 the 3G Quality CELL(Opt 114301 SH FDD cell Threshold ional) candidate Number of UTRAN SET FDD cells FDD GCELLC that FDDFRE GBFDMultirate BSC6900 CUTRAN should be QCNUM 114301 Reporting SYS(Opti included onal) in measure ment

GSM/WC DMA Interval Interopera Type bility

0~16383

GSM/WC DMA Interval Interopera Type bility

0~49

GSM/WC DMA Interval Interopera Type bility

0~3

FDDQMI N

FDD Qmin

This parameter specifies one of the parameter s for FDD cell reselectio n. A FDD cell becomes a candidate cell if all SET the GCELLC following GBFDBSC6900 CUTRAN conditions 114301 SYS(Opti are met onal) for five consecuti ve seconds: 1.Receive level of the FDD cell > Average receive level of the current serving cell +

GSM/WC DMA Interval Interopera Type bility

0~7

FDDQMI FDD NOFFSE Qmin T Offset

Offset of the minimum threshold for Ec/No during a FDD cell reselectio n. A FDD cell becomes a candidate cell if all SET the GCELLC following GBFDBSC6900 CUTRAN conditions 114301 SYS(Opti are met onal) for five consecuti ve seconds: 1.Receive level of the FDD cell > Average receive level of the current serving cell +

GSM/WC DMA Interval Interopera Type bility

0~7

FDDQOF FDD Q F Offset

SET GCELLC BSC6900 CUTRAN SYS(Opti onal)

SET GCELLC FDD REP FDDREP BSC6900 CUTRAN QUANT SYS(Opti onal)

This parameter specifies one of the threshold s of the signal level for 3G cell reselectio n. A FDD cell becomes a candidate cell if all the following conditions are met for five consecuti ve seconds: 1.Receive level of the FDD cell > Average receive level of the current This parameter specifies whether Ec/No or RSCP is used for the measure ment report on a FDD cell. Ec/No stands for the signalto-noise ratio. RSCP stands for the received signal code power.

GBFD114301

GSM/WC DMA Interval Interopera Type bility

0~15

GBFD114301 GBFD110801 GBFD110802

GSM/WC DMA Interopera bility Processin g of RSCP(RS Measure Enumerati CP), ment on Type EcN0(Ec/ Report N0) Preprocessin g of Measure ment Report

FDD FDDRSC RSCP PMIN Min.

Minimum level threshold of UTRAN cell reselectio n. During the cell reselectio n decision from a GSM cell to a FDD cell, this parameter SET is used to GCELLC calculate GBFDBSC6900 CUTRAN the RSCP 114301 SYS(Opti threshold onal) of the target cell. A FDD cell becomes a candidate cell if all the following conditions are met for five consecuti

GSM/WC DMA Interval Interopera Type bility

0~15

Minimum PS FDD ADD FDDRSC RSCP of RSCP GEXT3G GBFDPQUALT BSC6900 the 3G Quality CELL(Opt 114301 HRSH FDD cell Threshold ional) candidate

GSM/WC DMA Interval Interopera Type bility

0~63

Scramblin g code of a 3G cell, used for distinguis hing MSs or cells. Scramblin g codes are used after spreading . Therefore , the SET bandwidth GCELLID FDDSCR Scramblin of a signal GBFDBSC6900 LEFDDB AMBLE g Code 114301 is not A1(Mand changed. atory) Instead, signals from different sources are differentia ted. Scramblin g prevents multiple transmitte rs from using the Number of CPU usage sampling times for fast SET judgment. Fast FDWIND FCCPUT The value GBFDjudgemen BSC6900 OW HD(Optio of this 111705 t window nal) parameter must be of half size of "Filter window" or

GSM/WC DMA Interval Interopera Type bility

0~511

GSM Flow Control

Interval Type

1~1000

FER FERRPT Report EN Enable

Whether the BTS reports the frame erase SET ratio in a GCELLS measure GBFDBSC6900 OFT(Opti ment 116801 onal) report or preproces sed measure ment reportFER If the

Voice Quality Index (Uplink VQI)

Enumerati NO(No), on Type YES(Yes)

carried in the measure ment report (MR) received is lower than or equal to "FER threshold 1", the value of SET "FER 0 FER FERSTAT GCELLO and GBFDThreshold BSC6900 TH1 THEXT(O Quality 116801 1 ptional) Level N" is increment ed by one. If the FER in the MR received is greater than "FER threshold 1" but meanwhil e lower than or equal to

Voice Quality Index (Uplink VQI)

Interval Type

0~1000

SET FER FERSTAT GCELLO Threshold BSC6900 TH2 THEXT(O 2 ptional)

SET FER FERSTAT GCELLO Threshold BSC6900 TH3 THEXT(O 3 ptional)

If the FER carried in the MR received is greater than "FER threshold 2" but meanwhil e lower than "FER threshold 3", the value of "FER 2 and Quality Level N" is increment ed by If the FER carried in the MR received is greater than "FER threshold 3" but meanwhil e lower than "FER threshold 4", the value of "FER 3 and Quality Level N" is increment ed by

GBFD116801

Voice Quality Index (Uplink VQI)

Interval Type

0~1000

GBFD116801

Voice Quality Index (Uplink VQI)

Interval Type

0~1000

SET FER FERSTAT GCELLO Threshold BSC6900 TH4 THEXT(O 4 ptional)

SET FER FERSTAT GCELLO Threshold BSC6900 TH5 THEXT(O 5 ptional)

If the FER carried in the MR received is greater than "FER threshold 4" but meanwhil e lower than "FER threshold 5", the value of "FER 4 and Quality Level N" is increment ed by If the FER carried in the MR received is greater than "FER threshold 5" but meanwhil e lower than "FER threshold 6", the value of "FER 5 and Quality Level N" is increment ed by

GBFD116801

Voice Quality Index (Uplink VQI)

Interval Type

0~1000

GBFD116801

Voice Quality Index (Uplink VQI)

Interval Type

0~1000

SET FER FERSTAT GCELLO Threshold BSC6900 TH6 THEXT(O 6 ptional)

SET FER FERSTAT GCELLO Threshold BSC6900 TH7 THEXT(O 7 ptional)

If the FER carried in the MR received is greater than "FER threshold 6" but meanwhil e lower than "FER threshold 7", the value of "FER 6 and Quality Level N" is increment ed by If the FER carried in the MR received is greater than "FER threshold 7", the value of "FER 7 and Quality Level N" is increment ed by

GBFD116801

Voice Quality Index (Uplink VQI)

Interval Type

0~1000

GBFD116801

Voice Quality Index (Uplink VQI)

Interval Type

0~1000

SET GCELLH OPTP(Op tional) Frequenc SET FHMODE y Hopping BSC6900 GCELLH Mode OPQUIC KSETUP( Mandator y)

This parameter specifies the frequency hopping mode of a cell. When this parameter is set to "NO_FH", all the TRXs of the cell do not join in frequency GBFDhopping. 113701 When this parameter is set to "BaseBan d_FH", the cell is in baseband frequency hopping mode. In this case, there can be TRXs that do not join in

NO_FH(N o frequency hopping), BaseBan d_FH(Bas Frequenc eband y Hopping frequency (RF Enumerati hopping), hopping, on Type RF_FH(R baseband F hopping) frequency hopping), Hybrid_F H(Hybrid frequency hopping)

FILE

The name of the file cannot contain the path and suffix. The suffix is automatic ally added. The name of the file is EXP compose File Name BSC6900 LOG(Opti d of onal) English letters, numerals, and common symbols, and the character s (@, #, !, %, ^, &, *, [, ], /, \, ', and ") cannot appear in

GBFD111203 MRFD210305

O&M of BSC String Security Type Managem ent

None

FILE

Target File Path

GBFDZIP Path of 111203 BSC6900 FILE(Man the target MRFDdatory) file 210401

O&M of BSC BSC/RNC String Software Type Managem ent

None

Name of the backup file. The file name is compose d of English letters, BKP numerals, FileName File Name BSC6900 LOGDB( and Optional) common symbols, and the character s (@, #, !, %, ^, &, *, [, ], /, \, ', and ") cannot appear in

GBFD111203 MRFD210305

O&M of BSC String Security Type Managem ent

None

FILEPAT Export H File Path

EXP CFGMML (Optional) BSC6900 EXP GCELLTE MPLATE( Optional)

Path to save the exported file. The path must be a valid path on the OMU server. If the OMU runs the LINUX system, the input path must start with MRFDthe symbol "/" 210301 or "\", for example, "/mml". If the OMU runs the WINDOW S system, the input path can be a full path (for example, "D:\mml") or a relative path (for GBFD111203 MRFD210304

Configura tion String Managem Type ent

None

FILETYP Log File E Type

Type of EXP the alarm BSC6900 ALMLOG( log file to Optional) be exported

O&M of txt(.txt BSC Enumerati File), Faulty on Type csv(.csv Managem File) ent

Filter FILTERW Window NDSIZE Size

SET GCELLN BSC6900 C2PARA( Optional)

FIN

Final

EXP BSC6900 LOG(Opti onal)

Maximum number of former values when the receive level of the serving cell or the receive level of the neighbor cell is filtered. The greater the value, the greater the weight of the former receive levels; otherwise, the greater Execution result. If you select "FALSE", only the records of failed operation s are displayed. If you select "TRUE", only the records of successfu l operation s are displayed. If this parameter is not specified, all the records are

GBFD116201

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~32

GBFD111203 MRFD210305

O&M of FALSE(F BSC Enumerati ailed), Security on Type TRUE(Su Managem cceeded) ent

Whether to enable 0.2 dB downlink power 0.2dB SET control. FINESTE Power GCELLP This PPCALL BSC6900 Control WR3(Opti power OWED Enable onal) control function improves the power control precision. Whether to start the fireextinguish ing equipmen t of the BTS. In multimode Firescenario, SET extinguish the value BTSOUT FIRESET ing BSC6900 of this PUT(Opti Equipmen parameter onal) t in one mode must be the same as the value of the correspon ding parameter in another

GBFD117601

HUAWEI III Power Enumerati NO(No), Control on Type YES(Yes) Algorithm

GBFD111202

O&M of BTS

INACTIV E(Inactive Enumerati ), on Type ACTIVE( Active)

Fix Abis FIXABISP Prior RIORABI Choose SLOADT Load HRED Thred

This parameter specifies the static Abis resource load threshold. If the static Abis resource load is less than the static Abis SET resource BTSFLEX GBFDload BSC6900 ABISPAR threshold, 117301 A(Optiona the TCHF l) is preferenti ally allocated. Otherwise , whether the TCHF or the TCHH should be preferenti ally allocated is determine

Flex Abis

Interval Type

0~100

Time threshold for delaying the report of a clear alarm. If the alarm recurs within the time specified by this parameter after it is SET Flash cleared, BTSALMF FlashAlm Alarm the clear MRFDBSC6900 LASHTH ClrThd Clear alarm is 210304 D(Optiona Threshold not l) reported. Otherwise , the clear alarm is reported. If this parameter is set to 0, the clear alarm is reported immediat ely when the alarm is cleared.

Faulty Interval Managem Type ent

0~65534

SET Flash BTSALMF FlashAlm Alarm BSC6900 LASHTH OccurThd Occur D(Optiona Threshold l)

Flash FlashFilte Filter rEn Enable

SET BTSALMF BSC6900 LASHTW( Optional)

Time threshold for delaying the report of an alarm. If the alarm is cleared within the time specified by this parameter , the alarm is not reported. Otherwise , the alarm is reported. If this parameter is set to 0, the alarm is reported immediat ely when Whether to enable the filtering of the intermitte nt alarms. If the value of this parameter is "DISABLE ", "Flash Statis Alarm Raise Time Window" and "Flash Statis Alarm

MRFD210304

Faulty Interval Managem Type ent

0~65534

MRFD210304

DISABLE( Faulty DISABLE) Enumerati Managem , on Type ent ENABLE( ENABLE)

Flash Statistic FlashStati Alarm sAlmClrT Clear W Time Window

SET BTSALMF BSC6900 LASHTW( Optional)

Flash Statistic FlashStati Alarm sAlmOccu Raise rTW Time Window

SET BTSALMF BSC6900 LASHTW( Optional)

Time window for observing the clearance of the intermitte nt alarms. In this time window, the BTS statistical alarm is cleared if the occurrenc e of the intermitte nt alarm meets the related Time window for observing the intermitte nt alarms generated during the statistical period. In this time window, the BTS statistical alarm is reported if the occurrenc e of the intermitte nt alarm meets the related threshold.

MRFD210304

Faulty Interval Managem Type ent

60~65534

MRFD210304

Faulty Interval Managem Type ent

60~65534

Service timeslot assignme nt mode for the BTS. If this parameter is set to FIX_16K_ ABIS, the BSC6900 assigns a fixed Abis transmissi on ADD FLEXABI Flex Abis timeslot to GBFDBSC6900 BTS(Opti SMODE Mode a TCH. If 117301 onal) this parameter is set to FLEX_AB IS, the BSC6900 assigns an Abis transmissi on timeslot dynamical ly to a TCH (except the static

FIX_16K_ ABIS(Fix Abis), FLEX_AB Enumerati Flex Abis IS(Flex on Type Abis), SEMI_ABI S(Semisol id Abis)

Whether to enable the function of Flex mobile allocation index offset (MAIO). In the tight frequency reuse case of the GSM system, Start Flex ADD FLEXMAI adjacent- GBFDMAIO BSC6900 GCELL(O O channel 117001 Switch ptional) interferen ce and cochannel interferen ce easily occur between channels. If the frequency hopping function and the Flex MAIO function

Flex MAIO

Enumerati OFF(Off), on Type ON(On)

Whether to enable the function of the Flex training sequence code (TSC). If the value of this parameter SET is ON and FLEXTSC Flex TSC GCELLS BSC6900 the BTS SWITCH Switch OFT(Opti supports onal) the Flex TSC function, the BSS dynamical ly allocates TSCs to hopping frequenci es for improving the Flux FlowCoun Measure tPeriodTic ment ks Period SET BSCPSS BSC6900 OFTPAR A(Optiona l)

GBFD113521 GBFD118201 GBFD117001

A5/1 Encryptio n Flow Optimizati on Enumerati OFF(Off), Softon Type ON(On) Synchroni zed Network Flex MAIO

Period of collecting GBFDthe traffic 119501 statistics

Adaptive Adjustme nt of Interval Uplink Type and Downlink Channels

0~65535

Fast flux measure ment period. The ratio of the uplink flux to the SET downlink FLOWCO Fast Flux BSCPSS flux is UNTPERI Measure GBFDBSC6900 OFTPAR calculated ODTSRA ment 119501 A(Optiona at the PIDADJ Period l) interval specified by this parameter to determine the current service

Adaptive Adjustme nt of Interval Uplink Type and Downlink Channels

0~65535

FLOWCT Flow RLSWITC control H switch

SET Port flow ETHPOR BSC6900 control T(Optiona switch l)

None

None

Enumerati OFF(OFF on Type ), ON(ON)

FLOWCT Flow RLSWITC control H switch

ADD Link flow BSC6900 PPPLNK( control Optional) switch

None

None

Enumerati OFF(OFF on Type ), ON(ON)

FLOWCT Flow RLSWITC control H switch

ADD Link flow BSC6900 MPGRP( control Optional) switch

None

None

Enumerati OFF(OFF on Type ), ON(ON)

FLOWCT Flow RLSWITC control H switch

ADD IPLOGIC BSC6900 PORT(Op tional)

Logical port flow control switch

GBFD118611 GBFD118622

Abis IP over Enumerati OFF(OFF E1/T1 on Type ), ON(ON) A IP over E1/T1

FLOWCT Flow RLSWITC control H switch

ADD Port flow BSC6900 ETHTRK( control Optional) switch

None

None

Enumerati OFF(OFF on Type ), ON(ON)

FLOWCT Flow RLSWITC control H switch

SET BSCABIS BSC6900 PRIMAP( Optional)

Specified port flow control switch

GBFD118605 MRFD211503

IP QOS 2G/3G CoTransmis sion Enumerati OFF(OFF Resource on Type ), ON(ON) s Managem ent on MBSC

One of the nine parameter s (filter parameter s A1 to A8 and filter parameter B) used to configure the filter for determini ng SET whether Filter FLTPARA GCELLH the GBFDParamete BSC6900 A1 OEMG(O received 110601 r A1 ptional) signal level drops rapidly. The computati on formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt2t) + ... +

HUAWEI Interval I Type Handover

0~20

One of the nine parameter s (filter parameter s A1 to A8 and filter parameter B) used to configure the filter for determini ng SET whether Filter FLTPARA GCELLH the GBFDParamete BSC6900 A2 OEMG(O received 110601 r A2 ptional) signal level drops rapidly. The computati on formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt2t) + ... +

HUAWEI Interval I Type Handover

0~20

One of the nine parameter s (filter parameter s A1 to A8 and filter parameter B) used to configure the filter for determini ng SET whether Filter FLTPARA GCELLH the GBFDParamete BSC6900 A3 OEMG(O received 110601 r A3 ptional) signal level drops rapidly. The computati on formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt2t) + ... +

HUAWEI Interval I Type Handover

0~20

One of the nine parameter s (filter parameter s A1 to A8 and filter parameter B) used to configure the filter for determini ng SET whether Filter FLTPARA GCELLH the GBFDParamete BSC6900 A4 OEMG(O received 110601 r A4 ptional) signal level drops rapidly. The computati on formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt2t) + ... +

HUAWEI Interval I Type Handover

0~20

One of the nine parameter s (filter parameter s A1 to A8 and filter parameter B) used to configure the filter for determini ng SET whether Filter FLTPARA GCELLH the GBFDParamete BSC6900 A5 OEMG(O received 110601 r A5 ptional) signal level drops rapidly. The computati on formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt2t) + ... +

HUAWEI Interval I Type Handover

0~20

One of the nine parameter s (filter parameter s A1 to A8 and filter parameter B) used to configure the filter for determini ng SET whether Filter FLTPARA GCELLH the GBFDParamete BSC6900 A6 OEMG(O received 110601 r A6 ptional) signal level drops rapidly. The computati on formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt2t) + ... +

HUAWEI Interval I Type Handover

0~20

One of the nine parameter s (filter parameter s A1 to A8 and filter parameter B) used to configure the filter for determini ng SET whether Filter FLTPARA GCELLH the GBFDParamete BSC6900 A7 OEMG(O received 110601 r A7 ptional) signal level drops rapidly. The computati on formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt2t) + ... +

HUAWEI Interval I Type Handover

0~20

One of the nine parameter s (filter parameter s A1 to A8 and filter parameter B) used to configure the filter for determini ng SET whether Filter FLTPARA GCELLH the GBFDParamete BSC6900 A8 OEMG(O received 110601 r A8 ptional) signal level drops rapidly. The computati on formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt2t) + ... +

HUAWEI Interval I Type Handover

0~20

SET Filter FLTPARA GCELLH Paramete BSC6900 B OEMG(O rB ptional)

FLUSHT RANSFE RSWITC H

FLUSHLL PDU Transfer Switch

SET BSCPSS BSC6900 OFTPAR A(Optiona l)

Trend of the received signal level of the cell during a period. This parameter helps to configure the filter for determini ng whether the received signal level drops rapidly. If this parameter is higher, a more rapid signal level drop is required to trigger the This parameter determine s whether the BSC transfers the LLC PDUs in the buffer to the target cell or discards these LLC PDUs in the buffer when receiving the FLUSHLL message from the

GBFD110601

HUAWEI Interval I Type Handover

0~200

GBFD114101

GPRS

CLOSE(C Enumerati lose), on Type OPEN(Op en)

Maximum transmit power level of MSs. As one of the cell reselectio n parameter s in system message 3, this parameter SET is used to MS_TXP FMSMAX GCELLC control WR_MAX BSC6900 OPCC CCH(Opti the _CCH onal) transmit power of MSs. For details, see GSM Rec. 05.05. In a GSM900 cell, the maximum power control level of an MS ranges FMU FMUTYP Board E Type

GBFD111003 GBFD111101

Radio Common Channel Managem Interval ent Type System Informatio n Sending

0~19

SET Type of BTSFMU GBFDBSC6900 the FMUA ABP(Opti 111202 board onal)

O&M of BTS

INDOOR( Indoor), Enumerati OUTDOO on Type R(Outdoo r)

FN

Name of EXP the MRFDFile Name BSC6900 ELABEL( electronic 210303 Optional) label file

Inventory String Managem Type ent

None

FN

DLD LICENSE (Mandator Name of y) File Name BSC6900 the file ULD LICENSE (Mandator y) EXP Name of File Name BSC6900 DEVFILE( the file Optional)

GBFD111203 MRFD210401

O&M of BSC BSC/RNC String Software Type Managem ent

None

FN

GBFD111203

O&M of BSC

String Type

None

FN

EXP CFGMML (Optional) BKP DB(Optio nal) File Name BSC6900 RTR DB(Mand atory) EXP GCELLTE MPLATE( Optional)

FN

CHK DATA2LI C(Optiona File Name BSC6900 l) RVK LICENSE (Optional)

FN

DLD RETANT CFG(Man datory) EXP BTSDEV FILE(Opti onal) LOD File Name BSC6900 RETANT CFG(Man datory) ULD BTSLOG( Mandator y) DLD BTSSW( Mandator

Name of the file. The following special character s are not allowed in the file name: \, /, :, *, ?, ", <, >, |, (, ), &, and $. Name of the specified file. By default, the file is in the OMU activearea path \ftp\licens e folder.

MRFD210301

Configura tion String Managem Type ent

None

MRFD210403

License String Managem Type ent

None

File name of the software GBFDto be 111202 download ed

O&M of BTS

String Type

None

FN

DLD BTSPAT File Name BSC6900 CH(Optio nal)

SET Allow E BSCPSS FORBIDE Down G BSC6900 OFTPAR DGU Up Switch A(Optiona l)

File name of the software to be download ed.The file name must be with the extension of *.zip.If you do not enter the file name, all the valid files in the directory are download ed. These valid files are extracted from the patch Switch specifying whether to allow the downlink EGPRS TBF and the uplink GPRS TBF to share the same channel. On: allow the downlink EGPRS TBF and the uplink GPRS TBF to share the same channel; Off: prohibit the downlink EGPRS TBF and the uplink GPRS TBF

GBFD111202

O&M of BTS

String Type

None

GBFD113101 GBFD114201 GBFD119303 GBFD119501

PDCH Dynamic Adjustme nt EGPRS Load OPEN(Op Sharing Enumerati en), Adaptive on Type CLOSE(C Adjustme lose) nt of Uplink and Downlink Channels

Length of the timer for determini ng the intermitte nt disconnec tion of the SS7 link to the DPC. When the time of SS7 link Anti DPC ADD disconnec FORBIDN Intermitte GCNNOD tion GBFDO7FLASH nt BSC6900 E(Optiona exceeds 111804 DISC Disconne l) the period ct Timer specified by the timer, the BSC performs correspon ding operation s, including clearing the calls carried on the disconnec Time limit for SET restrainin GBFDBSC6900 TCPARA( g the 115601 Optional) noise level Whether the forced phase-2 GBFDaccess is 114101 allowed for the MSs

A Interface Protocol Process

Interval Type

1~300

Force Force_Li Limit mit_Time Time

Automatic Level Interval Control Type (ALC)

0~30

SET Force MS BSCPSS Force2Ph TwoBSC6900 OFTPAR ase phase A(Optiona Access l)

GPRS

Close(Clo Enumerati se), on Type Open(Op en)

Allow FORCED Forced CELLEFR EFR in SWITCH Cell

Whether to forcibly enable the EFR function. When this parameter is set to YES, if both the MS and the BSC6900 SET support GCELLS the BSC6900 OFT(Opti enhanced onal) full rate (EFR), the BSC6900 forcibly enables the EFR function even if the MSC does not support the function.

GBFD110501 GBFD113301

Call Control Enumerati NO(No), Enhanced on Type YES(Yes) Full Rate

Whether an MS is forced to send a Handover Access Force MS SET message, FORCEM to Send GCELLS which is SACCES Ho BSC6900 OFT(Opti indicated S Access onal) by an SWITCH informatio n element in the handover command . Port No. of the Dest ADD father Father BTSAUT FPN BSC6900 BTS BTS Port OPLAN(M connecte No. andatory) d with the BTS

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

GBFD111202

O&M of BTS

Interval Type

0~31

FPN

Number Dest ADD of the port Father BTSCON for the GBFDBSC6900 BTS Port NECT(Ma destinatio 111202 No. ndatory) n father BTS

O&M of BTS

Interval Type

0~23

Maximum time of delay for multiplexi ng. This parameter is used for the system to send the multiplexe d data. If the time Maximum ADD for FPTIMER Delay BSC6900 IPMUX(O buffering Time[ms] ptional) the data exceeds this value, the system does not wait for the multiplexi ng of other packets. In this way, the Whether to generate SET the Freq. and FQBSICO BTSAUT frequency BSIC PTSWITC BSC6900 OPLANC and BSIC Optimize H FG(Optio by using Switch nal) the automatic optimizati on

None

None

Interval Type

1~30

GBFD510702 GBFD510607

Compact BTS Enumerati OFF(OFF Automatic on Type ), ON(ON) Capacity Planning

SET Freq. and BTSAUT FQBSICS BSIC BSC6900 OPLANC WITCH Plan FG(Optio Switch nal)

SET Freq. and BTSAUT FQBSICS BSIC BSC6900 OPLANC WITCH1 Plan FG(Optio Switch nal)

If this switch is on, it indicates that the frequency and BSIC are generated automatic ally. If this switch is off, it indicates that the data must be configure d manually. If this switch is on, it indicates that the frequency and BSIC are generated automatic ally. If this switch is off, it indicates that the data must be configure d manually.

GBFD510601

PICO Automatic Enumerati OFF(OFF Configura on Type ), ON(ON) tion and Planning

GBFD510701

Compact BTS Automatic Enumerati OFF(OFF Configura on Type ), ON(ON) tion and Planning

FRAGSIZ MP flake E size

MP segment size,the ADD length of BSC6900 MPGRP( packet Optional) should be bigger or equel with it.

GBFD118604 GBFD118610

Abis MUX UDP MUX for Interval A Type Transmis sion

128~1024

Frame FRAMEO Offset FFSET [Frame No]

SET BTSEXC URSION( Mandator BSC6900 y) SET BSCSYN COFF(Ma ndatory)

Frame offset of the BTS clock

GBFD118201

SoftSynchroni Interval zed Type Network

2715647~ 2715647

FRAMEO Frame FFSET Offset

Frame offset. The frame offset technolog y arranges the frame numbers of different cells under the same BTS to be SET different GCELLO from one MRFDBSC6900 THEXT(O another 210301 ptional) by one frame offset. Thus, the FCH and SCH signals of neighbori ng cells do not appear in the same frame, which is helpful for the

Configura tion Interval Managem Type ent

0~255

Whether the downlink discontinu ous transmissi on (DTX) function is enabled for full rate (FR) calls. This function is also restricted SET by the FR Use GCELLB FRDLDT DTX Downlink BSC6900 ASICPAR X switch in DTX A(Optiona the MSC. l) If the MSC allows the downlink DTX for calls and the value of this parameter (FRDLDT X) is YES, the downlink DTX is enabled Time mode used when the log is exported. "ONTIME" indicates EXP the time BSC6900 LOG(Man between datory) two exact time. "RELATIV E_T" indicates the time before the current

GBFD114801 GBFD115501

Discontin uous Transmis Enumerati NO(No), sion on Type YES(Yes) (DTX) Downlink AMR FR

FREQ

Time Mode

GBFD111203 MRFD210305

ONTIME( O&M of Fixed BSC Enumerati Time), Security on Type RELATIV Managem E_T(Relat ent ive Time)

FREQ

Time Mode

Based on different requireme nts, you can set different time points for the scheduled task. Seven time modes are ADD available: SUBTSK( 1. GBFDBSC6900 Mandator ONTIME: 111203 y) When this parameter is set to "ONTIME" , the command is executed once only at the specified time point. 2. DAILY_T: When this

O&M of BSC

ONTIME( Fixed Time), DAILY_T( Day Based Schedulin g), DAILY_C( Day Based Duration), WEEKLY _T(Week Enumerati Based on Type Schedulin g), WEEKLY _C(Week Based Duration), MONTHL Y_T(Mont h Based Schedulin g), MONTHL Y_C(Mont h Based Duration)

FREQ

ADD Frequenc Frequenc GBFDBSC6900 GTRX(Ma y of the y 110101 ndatory) TRX

Frequenc Interval y Band Type

0~1023

FREQ1

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y1 ADD y1 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ10

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 10 ADD y 10 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ11

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 11 ADD y 11 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ12

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 12 ADD y 12 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ13

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 13 ADD y 13 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ14

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 14 ADD y 14 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ15

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 15 ADD y 15 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ16

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 16 ADD y 16 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ17

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 17 ADD y 17 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ18

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 18 ADD y 18 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ19

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 19 ADD y 19 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ2

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y2 ADD y2 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ20

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 20 ADD y 20 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ21

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 21 ADD y 21 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ22

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 22 ADD y 22 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ23

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 23 ADD y 23 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ24

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 24 ADD y 24 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ25

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 25 ADD y 25 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ26

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 26 ADD y 26 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ27

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 27 ADD y 27 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ28

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 28 ADD y 28 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ29

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 29 ADD y 29 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ3

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y3 ADD y3 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ30

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 30 ADD y 30 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ31

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 31 ADD y 31 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ32

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 32 ADD y 32 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ33

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 33 ADD y 33 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ34

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 34 ADD y 34 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ35

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 35 ADD y 35 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ36

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 36 ADD y 36 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ37

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 37 ADD y 37 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ38

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 38 ADD y 38 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ39

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 39 ADD y 39 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ4

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y4 ADD y4 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ40

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 40 ADD y 40 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ41

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 41 ADD y 41 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ42

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 42 ADD y 42 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ43

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 43 ADD y 43 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ44

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 44 ADD y 44 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ45

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 45 ADD y 45 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ46

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 46 ADD y 46 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ47

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 47 ADD y 47 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ48

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 48 ADD y 48 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ49

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 49 ADD y 49 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ5

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y5 ADD y5 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ50

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 50 ADD y 50 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ51

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 51 ADD y 51 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ52

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 52 ADD y 52 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ53

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 53 ADD y 53 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ54

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 54 ADD y 54 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ55

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 55 ADD y 55 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ56

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 56 ADD y 56 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ57

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 57 ADD y 57 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ58

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 58 ADD y 58 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ59

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 59 ADD y 59 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ6

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y6 ADD y6 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ60

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 60 ADD y 60 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ61

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 61 ADD y 61 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ62

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 62 ADD y 62 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ63

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 63 ADD y 63 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ64

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y 64 ADD y 64 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ7

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y7 ADD y7 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ8

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y8 ADD y8 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

FREQ9

ADD GCELLF REQ(Opti Frequenc onal) Frequenc GBFDBSC6900 y9 ADD y9 110101 GCELLM AGRP(Op tional)

Frequenc Interval y Band Type

0~1023

Whether to enable the automatic frequency correction algorithm. This parameter is used for the fastmoving handover algorithm. SET If the Frequenc FREQAD GCELLO parameter GBFDy Adjust BSC6900 J THEXT(O is set to 510101 Switch ptional) YES, the BTS calculates the speed at which an MS leaves or approach es it, and sends the BSC6900 the calculated speed in an uplink measure

AFC(Auto matic Frequenc Enumerati NO(No), y on Type YES(Yes) Correctio n)

Frequenc y correction parameter . Used for the fastmoving handover algorithm, the value of this parameter must be translated into a SET binary Frequenc FREQAD GCELLO number. GBFDy Adjust BSC6900 JVALUE THEXT(O The value 510101 Value ptional) consists of 16 bit. The most significant bit indicates whether the parameter is valid. Bits 14 to 8 indicate the level threshold. Bits 7 to 0 indicate

AFC(Auto matic Frequenc Interval y Type Correctio n)

0~65535

Frequenc y band types of the board This parameter is only applicable to the DDPU/DF CU/DFCB /DCOM/D DPM/DC BM. The ADD frequency Frequenc BTSANTF FREQBA MRFDband y Band BSC6900 EEDERB ND types for 210301 Attribute RD(Optio the nal) DTRU, QTRU, DRRU, DRFU, GRRU, MRRU, GRFU, and MRFU cannot be configure d and thus are calculated based on

PGSM90 0(PGSM9 00), EGSML2 5(EGSM< L25>), EGSM35 M(EGSM <35M>), RGSML2 5(RGSM< L25>), GSM900_ RGSM39 M(GSM90 Configura 0_RGSM tion Enumerati <39M>), Managem on Type DCS1800 ent (DCS180 0), PCS1900 (PCS190 0), GSM850( GSM850), EGSM24 M(EGSM <24M>), DCS1800 _L(DCS1 800<L50 M>), DCS1800 _H(DCS1

Threshold for load sharing in the 900 MHz frequency band. Assume that an MS supports multiple subbands in GSM900 the 900 FREQLO Band SET MHz ADSHAR Traffic GCELLC frequency GBFDBSC6900 ETRAFFT Load HMGAD( band. If 111005 HRSH Share Optional) the cell Threshold load is equal to or less than this threshold, the BSC does not consider the priority levels of the PGSM, EGSM, and R-GSM SET GCELLF List of FREQLS Freq GBFDBSC6900 REQSCA frequency T Band List 112401 N(Optiona bands l)

Enhanced Channel Interval Assignme Type nt Algorithm

0~100

Cell Interval Frequenc Type y Scan

0~1023

Frequenc y multiplexi ng mode in the TRX. To enable a loose frequency multiplexi ng mode SET such as FREQRE Frequenc GTRXDE 4x3 USEMOD y Reuse BSC6900 V(Optiona multiplexi E Mode l) ng, set this parameter to LOOSE. To enable a tight frequency multiplexi ng mode such as 1x3 or List of the frequenci es to be measured . This parameter is represent ed as a character STR Frequenc string FREQS BSC6900 NCS(Man y List where the datory) IDs of the TRXs to be measured are separated by &, such as 1&124&9 56.

MRFD210301

Configura LOOSE(L tion Enumerati oose), Managem on Type TIGHT(Ti ent ght)

GBFD510901

2G/3G Neighbori ng Cell String Automatic Type Optimizati on

None

Type of a scanning result in the period from the start of a frequency scanning task to the reporting of the scanning result. Frequenc Frequenc SET y FREQSC y Scan GCELLS scanning GBFDANRLSTT BSC6900 Result OFT(Opti refers to 112401 YPE Type onal) the scanning of an uplink receive level of a cell frequency . The scanning result reflects the strength of frequency

MainDiver sity(Main Diversity), Cell Enumerati Maximum Frequenc on Type MeanValu y Scan e(Maximu mMeanVa lue)

Whether to enable the edge handover algorithm. When an MS makes a call at the edge of a cell, the call may drop if the received signal SET level is FRINGEH Edge HO GCELLH too low. BSC6900 OEN Allowed OBASIC( To avoid Optional) such a call drop, the edge handover algorithm is involved. When the uplink signal level of the serving cell is less than "Edge HO

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

Whether the uplink DTX function is enabled for FR calls. For details, see GSM Rec. 05.08. Uplink DTX is not restricted SET by the GCELLB FRULDT FR Uplink MSC. If BSC6900 ASICPAR X DTX this A(Optiona parameter l) is set to May_Use, the MS can use DTX. If this parameter is set to Shall_Use or Shall_Not _Use, the MS cannot use DTX. ADD Slot No. BTSAUT of Father BSC6900 OPLAN(M BTS andatory) Slot No. of the father BTS

GBFD114803 GBFD115501

May_Use( Discontin May Use), uous Shall_Use Transmis (Shall Enumerati sion Use), on Type (DTX) Shall_NO Uplink T_Use(Sh AMR FR all not Use)

FSN

GBFD510701

Compact BTS Automatic Interval Configura Type tion and Planning

0~23

FSN

Slot No. ADD Slot No. for the BTSCON GBFDof Father BSC6900 port of the NECT(Op 111202 BTS father tional) BTS

O&M of BTS

Interval Type

0~23

FSRN

Subrack No. of Parent BTS

ADD BTSAUT BSC6900 OPLAN(M andatory)

Subrack No. of the GBFDfather 510701 BTS

Compact BTS Automatic Interval Configura Type tion and Planning

0~255

FSRN

Subrack No. of Father BTS

Subrack ADD No. for BTSCON GBFDBSC6900 the port of NECT(Op 111202 the father tional) BTS

O&M of BTS

Interval Type

0~254

FT

Type of the file EXP used for File Type BSC6900 LOG(Opti saving onal) exported logs

GBFD111203 MRFD210305

O&M of TXT(Plain BSC Text Enumerati Security Type), on Type Managem CSV(CSV ent Type)

FTI

Factor table index

ADD ADJMAP( BSC6900 Mandator y)

Activation factor GBFDtable 118605 index

IP QOS

Interval Type

0~33

FTI

Factor table index Factor table index

FTI

ADD TRMFAC BSC6900 TOR(Man datory) SET BSCABIS BSC6900 PRIMAP( Mandator y)

Activation factor GBFDtable 118605 index Activation factor None table index

IP QOS

Interval Type

1~33

None

Interval Type

0~33

FULLTOH ALFHOA TCBOFF SET

F-H ATCB Offset Overlay

ATCB difference SET between GCELLH the GBFDBSC6900 OBASIC( overlaid 510501 Optional) and underlaid subcells

HUAWEI Interval II Type Handover

0~255

FULLTOH F-H Ho ALFHOD Duration URATION

Duration of the handover from full rate to half rate. If the cell load is greater than the preset threshold, SET the calls GCELLH that meet GBFDBSC6900 OBASIC( the 510501 Optional) conditions for the handover from full rate to half rate are handed over from full rate to half rate in this duration.

HUAWEI Interval II Type Handover

0~600

According to the P/N rule, if the conditions for the handover from full rate to half rate are met SET FULLTOH for P F-H Ho GCELLH GBFDALFHOLA BSC6900 seconds Last Time OBASIC( 510501 STTIME within N Optional) seconds, the handover is triggered. This parameter specifies the number

HUAWEI Interval II Type Handover

1~32

FULLTOH ALFHOP ATHOFF SET

F-H Pathloss Offset Overlay

Path loss difference SET between GCELLH the GBFDBSC6900 OBASIC( overlaid 510501 Optional) and underlaid subcells

HUAWEI Interval II Type Handover

0~255

FULLTOH F-H Ho ALFHOP Period ERIOD

Period of the handover from full rate to half rate. If the cell load is greater than the preset threshold, the calls that meet the SET conditions GCELLH for the GBFDBSC6900 OBASIC( handover 510501 Optional) from full rate to half rate are handed over in "HF Ho Duration". This parameter specifies the bandwidth to be handed over at

HUAWEI Interval II Type Handover

0~600

SET FULLTOH F-H Ho GCELLH ALFHOS BSC6900 Stat. Time OBASIC( TATTIME Optional)

Forward ADD FWDCON congestio TRMLOA BSC6900 GBW n remain DTH(Opti bandwidth onal)

Forward ADD congestio FWDCON TRMLOA n clear BSC6900 GCLRBW DTH(Opti remain onal) bandwidth

According to the P/N rule, if the conditions for the handover from full rate to half rate are met for P seconds within N seconds, the handover is triggered. This parameter specifies the number N. If the available forward bandwidth is less than or equal to this value, the forward congestio n alarm is emitted and forward congestio n control is If the available forward bandwidth is greater than this value, the forward congestio n alarm is cleared and forward congestio n control is stopped.

GBFD510501

HUAWEI Interval II Type Handover

1~32

GBFD118605

IP QOS

Interval Type

0~200000

GBFD118605

IP QOS

Interval Type

0~200000

Forward ADD congestio FWDCON TRMLOA n clear BSC6900 GCLRTH DTH(Opti remain onal) ratio

Forward ADD FWDCON congestio TRMLOA BSC6900 GTH n remain DTH(Opti ratio onal)

Forward overload ADD FWDOVL congestio TRMLOA DCLRRS BSC6900 n clear DTH(Opti VBW remain onal) bandwidth

If the ratio of available forward bandwidth is greater than this value, the forward congestio n alarm is cleared and forward congestio n control is If the ratio of available forward bandwidth is less than or equal to this value, the forward congestio n alarm is emitted and forward congestio n control If the available forward bandwidth is greater than this value, the forward overload congestio n alarm is cleared and forward overload control is stopped.

GBFD118605

IP QOS

Interval Type

0~100

GBFD118605

IP QOS

Interval Type

0~100

GBFD118605

IP QOS

Interval Type

0~200000

Forward overload ADD FWDOVL congestio TRMLOA BSC6900 DCLRTH n clear DTH(Opti remain onal) ratio

Forward ADD overload FWDOVL TRMLOA congestio BSC6900 DRSVBW DTH(Opti n remain onal) bandwidth

Forward ADD overload FWDOVL TRMLOA congestio BSC6900 DTH DTH(Opti n remain onal) ratio

If the ratio of available forward bandwidth is greater than this value, the forward overload congestio n alarm is cleared and forward overload control is stopped. If the available forward bandwidth is less than or equal to this value, the forward overload congestio n alarm is emitted and forward overload control is triggered. If the ratio of available forward bandwidth is less than or equal to this value, the forward overload congestio n alarm is emitted and forward overload control is

GBFD118605

IP QOS

Interval Type

0~100

GBFD118605

IP QOS

Interval Type

0~200000

GBFD118605

IP QOS

Interval Type

0~100

Forward ADD FWDRES handover TRMLOA BSC6900 VHOTH reserved DTH(Opti ratio onal)

Forward ADD FWDRSV handover TRMLOA BSC6900 HOBW reserved DTH(Opti bandwidth onal)

Ratio of reserved forward bandwidth for handover user Reserved forward bandwidth for handover user If the load balance between a 2G cell and a 3G cell is greater than the threshold, load balance is triggered. Coefficien t used to modulate the load level of a 2G system so that the load level of the 2G system can be compared with that of a 3G system. G711

GBFD118605

IP QOS

Interval Type

0~100

GBFD118605

IP QOS

Interval Type

0~200000

CS 2G SET G2G3GLd 3G Load OTHSOF BlcDeltaT Balance BSC6900 TPARA(O hrd Delta ptional) Threshold

GBFD114322

GSM/WC DMA Interval Load Type Based Handover

0~200

2G Load SET G2GLoad Adjustme GCELLH AdjustCo nt BSC6900 OINTERR eff Coefficien ATLDB(O t ptional)

GBFD114322

GSM/WC DMA Interval Load Type Based Handover

0~100

G711_Mo G711 de Mode

Mode. A/U law SET configurat GBFDBSC6900 TCPARA( 118602 ion, 0-A Optional) law (default), 1-U law

A over IP

Enumerati A0, U1 on Type

GAMMA

GAMMA

Expected signal receiving strength SET on the GCELLP BTS side GBFDBSC6900 SPWPAR when 119115 A(Optiona GPRS l) dynamic power control is implemen ted

Power Control

Interval Type

0~31

End time Offset for Informatio ADD collecting GBFDGATHET n BSC6900 AISSCFG the offset 118201 Collection (Optional) informatio End Time n Cell load threshold for collecting the offset informatio Load ADD n. If the GATHLO Threshold GBFDBSC6900 AISSCFG load D of Offset 118201 (Optional) threshold Collection is exceeded , the offset informatio n is not Offset Whether ADD Informatio to collect AISSCFG GBFDGATHON n BSC6900 the offset (Mandator 118201 Collection informatio y) Switch n Offset Start time Informatio for ADD n collecting GBFDGATHST BSC6900 AISSCFG Collection the offset 118201 (Optional) Start informatio Time n

SoftSynchroni Compoun hour, min zed d Type Network

SoftSynchroni Interval zed Type Network

0~100

SoftSynchroni Enumerati OFF(OFF zed on Type ), ON(ON) Network

SoftSynchroni Compoun hour, min zed d Type Network

Obtains the QoS parameter from the Aggregat e BSS QoS Profile (ABQP) of packet flow context (PFC) when the MS and SET the GCELLP Support network GBFDGBRQOS BSC6900 SOTHER GBR QoS support 119901 PARA(Op the PFC; tional) obtains the QoS parameter from the uplink request originated by the MS or the DL UNITDAT A of the SGSN. GBR: guarantee d bit rate.

NO(Not Streaming Enumerati Support), QoS(GBR on Type YES(Sup ) port)

GCChk

Group Call Check

GCDF

GCDF

This parameter specifies whether to enable the VGCS/VB S check function. If the BSS works abnormall y, the BTS may periodicall SET y send BSCBASI BSC6900 notificatio C(Optiona n l) message s even if VGCS/VB S is over. In this case, an MS responds continuou sly but cannot access this VGCS/VB S TCH. of Format the geographi c ADD coordinat BSC6900 GPS(Opti es. The onal) values include "DEG" and

GBFD510301 GBFD510302

Public Voice Group Call Enumerati OFF(Off), Service on Type ON(On) Public Voice Broadcast Service

MRFD210502

DEG(DE BSC/RNC Enumerati G), Clock on Type SEC(SEC )

VGCS SET GCSCHN Channel GCELLG ASSULC Assign in BSC6900 SMR(Opti HNEN Channel onal) Enable

SET GCSIMP VGCS IM GCELLG REEMPTI Preemptio BSC6900 SMR(Opti ONEN n Enable onal)

Whether the assignme nt of channels in overlaid subcells is enabled for the VGCS service in the case of underlaid subcell congestio n. Generally, only the channels in underlaid subcells can be assigned to the VGCS Whether direct preemptio n of the channels of other services is enabled for the VGCS service. If the value of this parameter is NO, a handover is performe d for the call whose channel is preempte d. If the value is YES, calls on the preempte d channel

GBFD510301 GBFD510302

Public Voice Group Call Enumerati NO(No), Service on Type YES(Yes) Public Voice Broadcast Service

GBFD510307

Group Call EMLPP

Enumerati NO(No), on Type YES(Yes)

Global routing managem ent switch. If this switch is SET Global turned on, GLOBAL GLOBAL route the IP ROUTES BSC6900 ROUTES None managem addresse W W(Manda ent switch s in the tory) controlled range cannot be in the same network segment. Delay of transmit diversity when GMSK is used. Generally, the parameter is applicable to general fading environm ents. In SET Diversity this case, GCELLB GMSKDE Transmitt GBFDthe BSC6900 ASICPAR LAY er GMSK transmit 114101 A(Optiona Delay diversity l) can obtain the gain of 3 dB to 5 dB. The fading degrees, however, vary with environm ents. For a fixed delay, different UEs may

None

OFF(Disa ble the golbal route managem Enumerati ent), on Type ON(Enabl e the golbal route managem ent)

GPRS

Interval Type

4~32

GPRS

GPRS

SET GCELLG BSC6900 PRS(Man datory)

Whether the current cell supports GPRS

GBFD111101 GBFD114101

NO(Not support), SupportA sInnPcu( Support System as built-in Informatio Enumerati PCU), n Sending on Type SupportA GPRS sExtPcu( Support as external Pcu) NO(Not Support), SupportA sInnPcu( Support Enumerati As Inner on Type Pcu), SupportA sExtPcu( Support As Outer

GPRS

Support GPRS

ADD GCELLQ BSC6900 UICKSET UP(Optio nal)

Whether the currently GBFDcell 114101 supports the GPRS

GPRS

GPRSCE LLRESEL ECTHYE STERESI S

Hysteresi s value of the cell in the same routing area. When the MS in the ready state reselects a cell, if the original cell and GPRS SET the target Cell GCELLR cell are in GBFDReselect BSC6900 ESELECT the same 114101 Hysteresi PARA(Op routing s tional) area, the C2 values of the two cells at the border of the cell are quite different due to radio channel fading. As a result, the MS frequently

GPRS

0dB(0dB), 2dB(2dB), 4dB(4dB), 6dB(6dB), 8dB(8dB), Enumerati 10dB(10d on Type B), 12dB(12d B), 14dB(14d B)

PDCH GPRSCH Channel PRI Priority Type

EGPRS priority type of the channel If this parameter is set to GPRS, the EDGE MSs cannot use this channel. If this SET parameter GTRXCH is set to GBFDBSC6900 AN(Optio EGPRSN 114201 nal) ORCH, the GPRS and EDGE MSs can use this channel at the same priority. If this parameter is set to EGPRSP RICH, the EDGE

EGPRS

GPRS(G PRS Channel), EGPRSN ORCH(E GPRS Normal Channel), EGPRSP RICH(EG Enumerati PRS on Type Priority Channel), EGPRSS PECH(EG PRS Special Channel), NONGPR S(NonGPRS Channel)

Threshold of hierarchic al cell structure (HCS) signal strength. The MS calculates SET the C31 Threshold GCELLS according GPRSHC of HCS GBFDBSC6900 ERVPAR to the STHR Signal 114101 A(Optiona signal Strength l) strength and its threshold and selects the adjacent cell during cell reselectio n.

GPRS

DB110(110dB), DB108(108dB), DB106(106dB), DB104(104dB), DB102(102dB), DB100(100dB), DB98(98dB), DB96(96dB), Enumerati DB94(on Type 94dB), DB92(92dB), DB90(90dB), DB88(88dB), DB86(86dB), DB84(84dB), DB82(82dB), DB80(80dB), DB78(78dB),

GPRSPE GPRS NALTYTI Penalty ME Time

SET GCELLN CRESEL BSC6900 ECTPAR A(Optiona l)

Timer used when the MS calculates the C2 (used to evaluate the channel quality GBFDduring cell 114101 reselectio n). The time informatio n is transmitte d in the system message of each cell.

GPRS

Used for the GPRS transmissi on quality statistics. When the transmissi SET on quality GPRSRX GPRS GCELLN threshold GBFDQUALLIM Quality BSC6900 C2PARA( is 116201 IT Threshold Optional) exceeded , the transmissi on quality is regarded deteriorat ed.

10sec(10 sec), 20sec(20 sec), 30sec(30 sec), 40sec(40 sec), 50sec(50 sec), 60sec(60 sec), 70sec(70 sec), 80sec(80 sec), Enumerati 90sec(90 on Type sec), 100sec(1 00sec), 110sec(1 10sec), 120sec(1 20sec), 130sec(1 30sec), 140sec(1 40sec), 150sec(1 50sec), 160sec(1 60sec), 170sec(1 70sec),

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~7

SET GCELLN GPRSTE GPRS CRESEL MPOFFS Temporar BSC6900 ECTPAR ET y Offset A(Optiona l)

GPSORG GPS or LONASS Glonass

SET BTSDGP SBP(Opti onal) BSC6900 SET BTSUSC UBP(Opti onal)

This parameter is used to prevent repeated cell reselectio n of a fast moving MS. The MS does not select this cell when the duration of maintainin g the BCCH signal channel strength does not reach the penalty time. Synchroni zation clock adopted when two satellite cards are used together. GPS:Trac e GPS only. GLONAS S:Trace GLONAS S only. GPSGlon ass:Trace GPS and GLONAS

GBFD114101

GPRS

0db(0db), 10db(10d b), 20db(20d b), 30db(30d b), 40db(40d Enumerati b), on Type 50db(50d b), 60db(60d b), infinity(infi nity), nouse(no use)

GBFD510401 MRFD210501

GPS(GPS ), BTS GPS GLONAS Synchroni Enumerati S(Glonas zation on Type s), BTS/Nod GPSGlon eB Clock ass(GPS Glonass)

GPS data ADD Period for GPSPERI MRFDreport BSC6900 GPS(Opti reporting OD 210502 period onal) GPS data

BSC/RNC Interval Clock Type

1~60

GRADEA Grade CCALLO Access W Allow

SET GCELLC BSC6900 HMGBASI C(Optiona l)

SET GROUPC Group BTSCHN ALLNUM Call Num BSC6900 FALLBAC 1 1 K(Mandat ory)

Whether to allow hierarchic al access and to reserve resources for highpriority MSs Number of the VGCS call that the BTS originates in the timeslot in the TRX in fallback mode. This parameter is represent ed in decimal, such as 10000569 . If this parameter is set to 10000000 0, the channel is not configure d with any fixed

GBFD116001

Resource Enumerati NO(No), Reservati on Type YES(Yes) on

GBFD510309

Group Call Interval Reliability Type Enhancin g

0~100000 000

Number of the VGCS call that the BTS originates in the timeslot in the TRX in fallback mode. This SET parameter GROUPC Group BTSCHN is GBFDALLNUM Call Num BSC6900 FALLBAC represent 510309 2 2 K(Mandat ed in ory) decimal, such as 10000569 . If this parameter is set to 10000000 0, the channel is not configure d with any fixed

Group Call Interval Reliability Type Enhancin g

0~100000 000

GROUPI NDEX

BSC Node SET Redunda GBSCRE BSC6900 ncy DGRP(M Group andatory) Index

BSC Node SET GROUPN Redunda GBSCRE BSC6900 AME ncy DGRP(Op Group tional) Name

Index of the BSC Node Redunda ncy Group. It identifies a BSC redundan cy group. The BSC node redundan cy is a function through which two BSCs form a redundan cy group. The two BSCs in a redundan cy group work in 1+1 load sharing mode. When one BSC in a redundan cy group Name of the BSC Node Redunda ncy Group

GBFD113725

BSC Node Interval Redunda Type ncy

0~65534

GBFD113725

BSC Node String Redunda Type ncy

None

Group GROUPR Release ELTSNU TS M Number

Maximum number of secondar y links that are SET released BTSFLEX in batches GBFDBSC6900 ABISPAR when the 117301 A(Optiona Abis l) resource preemptio n occurs on the Abis interface

Flex Abis

Interval Type

0~512

GRPID

GRPT

ADD RSCGRP Transport (Mandator Resource BSC6900 y) Group SET No. BTSIP(Ma ndatory) Transport ADD Resource RSCGRP BSC6900 Group (Mandator Type y)

Transport resource GBFDgroup 118605 number Type of the transport resource group Geograph ical coverage of a simple cell broadcast message. You can run "DSP GSMSCB " to query and obtain the informatio n. This parameter , "Code", and "Update" uniquely specify a cell broadcast message. Ratio of bandwidth occupied by the CS service in the GSM Standard priority for GSM CS(Circuit Switched) highpriprity MSs. 15 is the highest priority.

IP QOS

Interval Type

0~2047

GBFD118605

IP QOS

Enumerati IP(IP) on Type

GS

SET GCELLS BC(Optio Geograph nal) BSC6900 y Scope ADD GSMSCB (Mandator y)

GBFD113602

LAC_CI(C ELL IMME), Simplified Enumerati PLMN(AL Cell on Type L), Broadcast LAC(LAC) , CI(CELL)

GSMCSB CS ratio WRATE

ADD TRMLOA BSC6900 DTH(Opti onal)

GBFD118605

IP QOS

Interval Type

0~100

GSM CS SET GSMCSU High BSCBASI SERHIGH BSC6900 Level C(Optiona PRILEV Standard l)

GBFD118605

IP QOS

Interval Type

1~15

Number of neighbori ng cells that meet the following conditions : If "MBR" is indicated in a system message, the MS SET reports Serving GCELLC GSMFRE GBFDthe Band BSC6900 CUTRAN QCNUM number of 114401 Reporting SYS(Opti neighbori onal) ng cells at each frequency band. If the MS reports the number of neighbori ng cells at the same frequency band of the serving Whether to support the cell reselectio GSM-toSET n from the GSMTOT TD Cell GCELLP GSM GBFDDALLOW Reselecti BSC6900 SOTHER network 114302 ED on PARA(Op to the TD Allowed tional) network in the packet transmissi on mode

Multiband Interval Sharing Type One BSC

0~3

UNSUPP GSM/TDORT(Not SCDMA Enumerati Support), Interopera on Type SUPPOR bility T(Support )

ICMP Packet ADD type type GUARDT ICMPGU GBFDwhich will BSC6900 against YPE ARD(Man 111202 be the ICMP datory) guarded attack

O&M of BTS

Bit Field Type

GWIP

GWIP

When the BTS is accessed from the public ADD BTS network, BTSAUT SeGW IP BSC6900 the BTS OPLAN(O Address security ptional) network IP address must be configure IP address of the BTS security gateway. This BTS parameter Security SET needs to Gateway BSC6900 BTSIP(Op be IP tional) configure Address d when the BTS connects to the BSC6900 through the public

ECHORE PLY, UNREAC H, SOURCE QUENCH , REDIREC T, ECHO, ROUTER ADVERT, ROUTER SOLICIT, TIMXCEE D, PARAMP ROB, TSTAMP, TSTAMP REPLY, IREQ, IREQREP LY, MASKRE Q, MASKRE PLY

GBFD118601

IP Abis over Address IP Type

None

GBFD118601

IP Abis over Address IP Type

None

Whether Support SET HalfRate to support Half Rate OTHSOF GBFDDataSupp BSC6900 CS half Data TPARA(O 113401 ort rate data Service ptional) services

Half Rate Enumerati NO(No), Speech on Type YES(Yes)

H-F HALFTOF ATCB ULLATCB Offset OFFSET Overlay

ATCB difference SET between GCELLH the GBFDBSC6900 OBASIC( overlaid 510501 Optional) and underlaid subcells

HUAWEI Interval II Type Handover

0~255

HALFTOF H-F Ho ULLHOD Duration URATION

Duration of the handover from half rate to full rate. If the cell load is less than the preset threshold, SET the calls GCELLH that meet GBFDBSC6900 OBASIC( the 510501 Optional) conditions for the handover from half rate to full rate are handed over from half rate to full rate in this duration.

HUAWEI Interval II Type Handover

0~600

According to the P/N rule, if the conditions for the handover from half rate to full rate are met for P SET HALFTOF seconds H-F Ho GCELLH GBFDULLHOLA BSC6900 within N Last Time OBASIC( 510501 STTIME seconds, Optional) the handover is triggered. This parameter specifies the number P.

HUAWEI Interval II Type Handover

1~32

HALFTOF ULLHOP ATHOFF SET

H-F Pathloss Offset Overlay

Path loss difference SET between GCELLH the GBFDBSC6900 OBASIC( overlaid 510501 Optional) and underlaid subcells

HUAWEI Interval II Type Handover

0~255

According to the P/N rule, if the conditions for the handover from half rate to full rate are met for P SET HALFTOF seconds H-F Ho GCELLH GBFDULLHOS BSC6900 within N Stat. Time OBASIC( 510501 TATTIME seconds, Optional) the handover is triggered. This parameter specifies the number N.

HUAWEI Interval II Type Handover

1~32

Whether the towerSET top Antenna BTSRXU amplifier HAVETT1 Tributary BSC6900 BP(Optio is 1 Flag nal) installed on antenna Whether SET Antenna BTSRXU HAVETT2 Tributary BSC6900 BP(Optio 2 Flag nal) the towertop amplifier is installed on antenna

GBFD111202 MRFD210601

O&M of BTS Connectio NO(NO), Enumerati n with YES(YES on Type TMA ) (Tower Mounted Amplifier) O&M of BTS Connectio NO(NO), Enumerati n with YES(YES on Type TMA ) (Tower Mounted Amplifier)

GBFD111202 MRFD210601

ADD Heartbeat SCTPLN HBINTER BSC6900 interval K(Optiona l)

Heartbeat interval when the GBFDSCTP 118602 server is idle

A over IP

Interval Type

1000~600 000

HCN

Head Cabinet No.

Number of the cabinet ADD where the BTSRXU GBFDBSC6900 main CHAIN(M 111202 board of andatory) the RXU chain or ring is

O&M of BTS

Interval Type

0~62

HCS HO HCSLAS Valid TTIME Time

According to the P/N rule, if the conditions for the handover to a different micro cell due to fast movemen ADD t are met G2GNCE GBFDBSC6900 in P of N LL(Option 510501 measure al) ment reports, the handover is triggered. This parameter specifies the number P.

HUAWEI Interval II Type Handover

1~16

HCS HO HCSSTA Watch TTIME Time

According to the P/N rule, if the conditions for the handover to a different micro cell due to fast ADD movemen G2GNCE t are met GBFDBSC6900 LL(Option in P of N 510501 al) measure ment reports, the handover is triggered. This parameter specifies the number

HUAWEI Interval II Type Handover

1~16

Hierarchic SET HIERPW al Power BSC6900 BTSBAT( RPARA1 Para1 Optional)

Hierarchic SET HIERPW al Power BSC6900 BTSBAT( RPARA2 Para2 Optional)

Threshold for interruptin g the power supply to the TRXs. If the BTS works with the battery power supply, when the battery voltage is less than this threshold, the BTS interrupts the power supply to the TRXs to protect the lowerlevel BTSs Threshold for interruptin g the power supply to the TMU. If the BTS works with the battery power supply, when the battery voltage is less than this threshold, the BTS interrupts the power supply to

GBFD111202

O&M of BTS

Interval Type

0~65535

GBFD111202

O&M of BTS

Interval Type

0~65535

Type of a high frequency type supported by the Support SET HiFreqBa BSC6900, High BSCBASI GBFDndSuppor BSC6900 Frequenci Frequenc C(Optiona 110101 t es on y Band l) DCS1800 : 512-885 Frequenci es on PCS1900: 512-810 Full rate TCHs are assigned preferenti ally to the MSs with priority SET levels HIGHEST Highest GCELLC equal to PRIORIT Priority for GBFDBSC6900 HMGBASI or less QUALFIR Quality 115001 C(Optiona than this ST First l) threshold, except when the MSs request only half or full rate TCHs.

DCS1800 Frequenc Enumerati , y Band on Type PCS1900

Enhanced Multi Level Preceden Interval ce and Type Preemptio n(EMLPP )

1~14

This parameter specifies whether the MS with priority level 1 directly releases the preempte d call. When this Highestparameter Priority SET is set to HIGHLEV MSs OTHSOF Yes, the GBFDBSC6900 PREEM Rapid TPARA(O access 115001 Preemptio ptional) delay of n MSs with high priorities is ensured and the access rate of MSs with high priorities is increased , but the preempte Whether Highest HIGHPRI Priority USERQU User ALFIRST Quality First to enable SET the GCELLC priorityGBFDBSC6900 HMGBASI based 115001 C(Optiona channel l) assignme nt algorithm Whether

Enhanced Multi Level Preceden Enumerati NO(No), ce and on Type YES(Yes) Preemptio n(EMLPP )

Enhanced Multi Level Preceden Enumerati NO(No), ce and on Type YES(Yes) Preemptio n(EMLPP )

to enable High SET load HIGHTE Temp BTSAPM power-off GBFDMPLOAD BSC6900 Load UBP(Opti against 111202 PWROFF Power Off onal) high temperatu re

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

History HISPRIO Record ALLOW Priority Allowed

Whether to consider history priority records during channel assignme nt. If this parameter SET is set to GCELLC YES, the GBFDBSC6900 HMGAD( history 111005 Optional) priority records are considere d. If this parameter is set to NO, the history priority records are not considere

Enhanced Channel Enumerati NO(No), Assignme on Type YES(Yes) nt Algorithm

Maximum SET Maximum HISTORY History PWDPOL History MRFDPWDNU BSC6900 Password ICY(Optio Password 210305 M Numbers nal) Numbers.

Security Interval Managem Type ent

1~10

Support HMCDTM HMC DTM

Whether the cell SET supports GCELLG the MS GBFDBSC6900 PRS(Opti with the 119404 onal) DTM multitimeslot capability

HMC DTM

UNSUPP ORT(Not Enumerati Support), on Type SUPPOR T(Support )

Pref. SET HOALGO Subcell in GCELLH PERMLA BSC6900 HO of OIUO(Opt Y Intra-BSC ional)

Handover ADD HOBTWN Between GCNOPE OTHOPA BSC6900 Operators RATOR( LLOW Allow Optional)

Whether to assign a channel in the overlaid or underlaid subcell in the case of the intra-BSC incoming handover to the concentric cell. If this parameter is set to SysOpt, the measured BCCH of the target cell is included in the intra-BSC inter-cell handover request message. Then, the BSC Whether to allow handover between different operators. If the BSC6900 supports RAN sharing, MSs in a cell of this operator can be handed over to a cell of other operators, or vice versa.

GBFD113201

SysOpt(S ystem optimizati on), OSubcell( Overlaid Concentri Enumerati subcell), c Cell on Type USubcell( Underlaid subcell), NoPrefer( No preferenc e)

GBFD118701

RAN Sharing

Enumerati NO(No), on Type YES(Yes)

If the downlink received signal level of a neighbor cell is greater than "Min DL Level on Min DL SET Candidate HOCDCM Level on GCELLH Cell" plus INDWPW BSC6900 Candidate OBASIC( "Min R Cell Optional) Access Level Offset", the neighbor cell can be listed in the candidate cell queue for handover.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

If the uplink received signal level of a neighbor cell is greater than "Min UL Level on Min UL SET Candidate HOCDCM Level on GCELLH Cell" plus INUPPW BSC6900 Candidate OBASIC( "Min R Cell Optional) Access Level Offset", the neighbor cell can be listed in the candidate cell queue for handover.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

Specify Index of SET HOCELLI Cell BSC6900 FHO(Man DTYPE Handover datory) to

Type of indexing GBFDthe target 111203 cell

O&M of BSC

BYCELLN AME(By Enumerati cell on Type name), BYCGI(By CGI)

Cell SET HOCELL Name of BSC6900 FHO(Man NAME Handover datory) to

Unique name of GBFDthe target 111203 cell

O&M of BSC

String Type

None

SET GCELLH OBASIC( Optional) SET GCELLH Current OEMG(O HOCTRL HO ptional) BSC6900 SWITCH Control SET Algorithm GCELLH OFITPEN (Optional) SET GCELLH OIUO(Opt ional)

Whether to use handover GBFDalgorithm 110601 generatio n 1 or 2 currently

HOALGO RITHM1( Handover algorithm HUAWEI Enumerati I), I on Type HOALGO Handover RITHM2( Handover algorithm II)

Handover direction forcast switch. When this parameter is set to YES, the BSC6900 can Handover SET forecast HODIRF Direction GCELLH the GBFDORECAS BSC6900 Forecast OFAST(O handover 510103 TEN Enable ptional) direction of the call in fast handover so that the best target cell can be selected for handover.

Chain Enumerati NO(No), Cell on Type YES(Yes) Handover

This parameter indicates P in the P/N rule for MS handover direction forcast. P/N rule: Among N handover s, the MS Handover is handed SET Direction over to HODIRLA GCELLH GBFDForecast BSC6900 Class B STTIME OFAST(O 510103 Last chain ptional) Times neighbori ng cell for successiv ely P times, then the BSC6900 determine s that the MS is moving to the Class B chain neighbori

Chain Interval Cell Type Handover

0~16

This parameter indicates N in the P/N rule for MS handover direction forcast. P/N rule: Among N handover s, the MS Handover is handed SET Direction over to HODIRST GCELLH GBFDForecast BSC6900 Class B ATIME OFAST(O 510103 Statistic chain ptional) Times neighbori ng cell for successiv ely P times, then the BSC6900 determine s that the MS is moving to the Class B chain neighbori

Chain Interval Cell Type Handover

0~16

Fast handover can be triggered only when Quick SET the Handover HODOW GCELLH downlink GBFDDown BSC6900 NTRIGE OFAST(O level of 510102 Trigger ptional) the Level serving cell is less than this parameter .

Fast Interval Move Type Handover

0~63

FDD 3G Better HODURT Cell HO 3G Valid Time

According to the P/N rule, if the conditions for the handover to a better 3G cell are met for P ADD seconds G3GNCE BSC6900 within N LL(Option seconds, al) the handover is triggered. This parameter specifies the number P.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~32

TDD 3G Better HODURT Cell HO 3GTDD Valid Time

According to the P/N rule, if the conditions for the handover to a better 3G cell are met for P ADD seconds G3GNCE BSC6900 within N LL(Option seconds, al) the handover is triggered. This parameter specifies the number P.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~32

The 3G better cell handover can be triggered only when Ec/No SET the Ec/No Threshold GCELLH HOECNO of a for Better BSC6900 OUTRAN TH3G neighbori 3G Cell FDD(Opti ng 3G cell HO onal) is greater than this threshold for a period of time.

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~49

According to the P/N rule, if the conditions for fast handover are met in P of N measure ADD Quick ment HOLAST G2GNCE GBFDHandover BSC6900 reports, TIME LL(Option 510102 Last Time the al) handover is triggered. This parameter specifies the number P.

Fast Interval Move Type Handover

1~32

HOMOD

Type of handover in terms of SET connectio Handover GBFDBSC6900 FHO(Man n transfer Scope 111203 datory) between channels or between cells

O&M of BSC

FREE(Fre e), INCELL(I ntra-cell), OUTCEL L(Outgoin g cell), OUTST(O utgoing Enumerati site), on Type OUTBSC( Outgoing BSC), OUTSYS( Outgoing system), SPCELL( Specified cell)

ADD GEXT2G CELL(Opt Quick HOOFFS ional) Handover BSC6900 ET SET Offset GCELLH OFAST(O ptional)

Fast handover can be triggered only when the path loss difference between the serving cell and a neighbor cell on the chain is equal to or greater than this parameter .

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~127

If the cell is an enhanced concentric cell, this parameter with the current downlink received signal level and "UtoO HO Received Level Handover SET Threshold HOOLRX to GCELLC " GBFDLEVOFFS Overlayer BSC6900 HMGAD( determine 113201 ET RxLev Optional) s whether Offset to assign a channel in the underlaid subcell to the intraBSC incoming handover to the concentric cell or intra-BSC inter-cell handover.

Concentri Interval c Cell Type

0~61

SET GCELLH OUTRAN Inter-rat FDD(Opti HOOPTS HO onal) BSC6900 EL Preferenc SET e GCELLH OUTRAN TDD(Opti onal)

Inter UL/OL HOPENA Subcells LTYTIME HO Penalty Time

SET GCELLH BSC6900 OEDBPA RA(Optio nal)

This parameter specifies whether a 2G cell or to a 3G cell is preferenti ally selected as the target cell for handover. When this parameter is set to Pre_2G_ Cell, the BSC preferenti ally selects a 2G candidate cell as the target cell for handover. When this parameter is set to Pre_3G_ Cell, the An MS cannot be handed over from the underlaid subcell to the overlaid subcell in this duration after the MS is handed over from the overlaid subcell to the underlaid subcell successfu

GBFD110601 GBFD510501

Pre_2G_ Cell(Prefe rence for 2G cell), HUAWEI Pre_3G_ I Cell(Prefe Handover Enumerati rence for HUAWEI on Type 3G cell), II Pre_2G_ Handover CellThres (Preferen ce 2G cell by thresh)

GBFD114402

Enhanced DualInterval Band Type Network

0~255

Index of the frequency hopping ADD data, HOPINDE GCELLM GBFDHop Index BSC6900 used for a X AGRP(Ma 113701 TRX to ndatory) locate the frequency hopping sequence SET GCELLM HOPINDE Hop Index BSC6900 AIOPLAN X (Mandator y)

Frequenc y Hopping (RF Interval hopping, Type baseband hopping)

0~63

Logical number of GBFDthe MA 117002 group

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~63

HOPMOD Hop E Mode

Implemen ADD tation GCELLM GBFDBSC6900 mode of AGRP(Ma 113701 frequency ndatory) hopping

Frequenc BaseBan y Hopping d_FH(Bas (RF Enumerati eBand hopping, on Type FH), baseband RF_FH(R hopping) F FH)

Power Boost HOPOW before ERBOOS HO T Enabled or Not

Whether to enable power boost before handover. When the receive level of an MS drops rapidly, a handover occurs. In this case, the SET BSC6900 GCELLO cannot GBFDBSC6900 THBASIC adjust the 117101 (Optional) transmit power of the MS and the BTS in time. The MS may fail to receive a handover command , thus leading to a call drop. If the value

NO(Not BTS StartUp), power lift Enumerati YES(Start for on Type Up), handover NONE(No ne)

SET GCELLH HO OUTRAN Preferenc FDD(Opti HOPRET e onal) BSC6900 H2G Threshold SET for 2G GCELLH Cell OUTRAN TDD(Opti onal)

If the receive level of the neighbori ng 2G cell that ranks the first in the candidate cell list is equal to or smaller than this threshold, the BSC preferenti ally selects a neighbori ng 3G cell as the handover target cell. Otherwise , the BSC preferenti ally selects a neighbori ng 2G cell as the handover If this

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

parameter is set to ON, the channel Hop on a Group SET HopSingl single Single OTHSOF GBFDeFreqOpt BSC6900 frequency Freq TPARA(O 113701 Switch of an MA Optimizati ptional) group is on allocated to an MS with the non-FH attribute.

Frequenc y Hopping (RF Enumerati OFF(Off), hopping, on Type ON(On) baseband hopping)

Hoping sequence number (HSN) of a hopping antenna group. If the value of this parameter is 0, the services over a TRX are adjusted ADD to other Hop TRX GCELLH HOPTRX TRXs in GBFDGroup BSC6900 OPANTG HSN 113703 the HSN RP(Optio hopping nal) antenna group in sequence . If this parameter is set to a value from 1 to 63, the services over a TRX are adjusted to other TRXs in

Antenna Interval Frequenc Type y Hopping

0~63

TRX index that a hopping antenna index correspon ds to. A hopping antenna enables signals of multiple TRXs to ADD switch Hop TRX GCELLH between HOPTRXI GBFDGroup BSC6900 OPANTG several NDEX 113703 Index RP(Mand antennas atory) instead of fixing an antenna for a TRX. This reduces the effect of Rayleigh fading on signals of some frequenci es.

Antenna Interval Frequenc Type y Hopping

0~23

Frequenc y hopping mode of the TRX. Frequenc y hopping assists in interferen ce averaging and frequency diversity. If this parameter SET is set to HOPTYP GTRXHO RF_FH, GBFDHop Type BSC6900 E P(Optiona the TX 113701 l) and RX parts of the TRX take part in the frequency hopping. In this case, the number of hopping frequenci es can exceed the number of

NO_FH(N o Frequenc y Hopping), Frequenc BaseBan y Hopping d_FH(Bas (RF Enumerati eband hopping, on Type Frequenc baseband y hopping) Hopping), RF_FH(R F Frequenc y Hopping)

ADD GEXT2G Quick CELL(Opt HOPUNIS Handover ional) BSC6900 HVALUE Punish SET Value GCELLH OFAST(O ptional)

To avoid ping-pong handover, the received signal of the original serving cell is decrease d by "Quick handover punish value" in "Quick handover punish time" after fast handover succeeds.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

BSC HO HOREFT Protect MR Time

Time for reserving the handover reference ADD for one of GBFDBSC6900 AISSCFG the two 118201 (Optional) BSCs that collect the offset informatio n

SoftSynchroni Interval zed Type Network

1~60

SET GCELLH OUTRAN RSCP FDD(Opti Threshold HORSCP onal) for Better BSC6900 TH3G SET 3G Cell GCELLH HO OUTRAN TDD(Opti onal)

The 3G better cell handover is triggered only when the RSCP of a neighbori ng 3G cell is greater than this threshold for a period of time.

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~63

Speech HoSdcch VER in SpeechV SDCCH er HO REQ ACK

Whether an HO REQ ACK message contains the informatio n element Speech Version during an SET SDCCH MSGSOF GBFDBSC6900 handover. TPARA(O 111804 If a ptional) signaling channel handover between BSCs fails, the value of this parameter may need to be

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

FDD 3G Better HOSTAT Cell HO 3G Watch Time

According to the P/N rule, if the conditions for the handover to a better 3G cell are met in P of N ADD measure G3GNCE BSC6900 ment LL(Option reports, al) the handover is triggered. This parameter specifies the number N.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~32

TDD 3G Better HOSTAT Cell HO 3GTDD Watch Time

According to the P/N rule, if the conditions for the handover to a better 3G cell are met in P of N ADD measure G3GNCE BSC6900 ment LL(Option reports, al) the handover is triggered. This parameter specifies the number N.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~32

According to the P/N rule, if the conditions for fast handover are met in P of N measure Quick ADD ment HOSTATI Handover G2GNCE GBFDBSC6900 reports, CTIME Static LL(Option 510102 the Time al) handover is triggered. This parameter specifies the number N. Indicates the host type of the signalling point. When the BSC node redundan cy feature is enabled, the primary BSC and The host the ADD HOSTTY type of secondar GBFDBSC6900 OPC(Opti PE signalling 113725 y BSC onal) point each must be configure d with a signaling point coded in the same mode. The host type of the signaling point of the primary

Fast Interval Move Type Handover

1~32

SINGLEH OST(SIN GLEHOS BSC T), Node Enumerati PRIMHO Redunda on Type ST(PRIM ncy HOST), SLAVEH OST(SLA VEHOST)

SET Host type HOSTTY GBFDHostType BSC6900 BTSIP(Op of an IP PE 113725 tional) BTS

SINGLEH OST(Sing le Host), BSC PRIMHO Node Enumerati ST(Primar Redunda on Type y Host), ncy SLAVEH OST(Slav e Host)

ADD GEXT2G CELL(Opt Inter-layer HOTHRE ional) HO BSC6900 S SET Threshold GCELLH OBASIC( Optional)

Handover threshold during the handover s between cells on different layers or of different priorities. This value is used to suppress inter-layer ping-pong handover s. Inter-layer handover threshold of the serving cell = "Interlayer HO threshold" - "Interlayer HO Hysteresi s"; Inter-layer handover threshold

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

Fast handover can be triggered only when Quick SET the uplink Handover HOUPTRI GCELLH signal GBFDUp BSC6900 GE OFAST(O level of 510102 Trigger ptional) the Level serving cell is less than this parameter .

Fast Interval Move Type Handover

0~63

Cell HPANTM Antenna ODE Hopping

Whether to enable the TRX to support antenna hopping In a GSM cell, the BCCH broadcast s the frequency , frame number, system SET informatio GCELLH n, and GBFDBSC6900 OPANT(O paging 113703 ptional) group. If an MS is in an unfavorab le position or the antenna of the main TRX that carries the BCCH fails, the MS receives poor

NO_HPA NT(No), Antenna Enumerati YES_HPA Frequenc on Type NT(Yes), y Hopping NONE(No ne)

Cell HPANTM Antenna ODE Hopping

SET GCELLH OPANTQ BSC6900 UICKSET UP(Mand atory)

Whether to enable the TRX to support antenna hopping In a GSM cell, the BCCH broadcast s the frequency , frame number, system informatio GBFDn, and 113703 paging group. If an MS is in an unfavorab le position or the antenna of the main TRX that carries the BCCH fails, the MS receives poor The

NO_HPA Antenna Enumerati NT(No), Frequenc on Type YES_HPA y Hopping NT(Yes)

HPN

number of the optical ADD port of the Head Port BTSRXU GBFDBSC6900 main No. CHAIN(M 111202 board in andatory) the RXU chain or ring.

O&M of BTS

Interval Type

0~5

HPRIOR

Highest Priority

SET GCELLC BSC6900 HMGBASI C(Optiona l)

HPVFLA G

SET BTSAPM Hierarchic UBP(Opti al Poweronal) BSC6900 off Config. SET Enabled BTSDPM UBP(Opti onal)

Maximum priority level of an MS that can use reserved channel resources . If the priority level of an MS is greater than this parameter , the MS is considere d a lowpriority MS. If the priority of an MS is equal to or less than this threshold, the MS is considere d a highpriority MS. Whether to enable the configurat ion of power system parameter s. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another

GBFD116001

Resource Interval Reservati Type on

1~14

GBFD111202 GBFD111601

O&M of BTS NO(NO), BTS Enumerati YES(YES Power on Type ) Managem ent

Load power-off voltage threshold. In multimode scenario, the value of this SET parameter Load BTSDPM in one HPVTHD Power-off BSC6900 UBP(Opti mode Voltage onal) must be the same as the value of the correspon ding parameter in another mode. This parameter determine s whether the BSC6900 supports new establish SET ment HRATES Support GCELLC causes of BSC6900 PT Half Rate CCH(Opti an MS in onal) the initial access request. This parameter does not affect the half-rate function of cells.

GBFD111202 GBFD111601

O&M of BTS BTS Interval Power Type Managem ent

350~556

GBFD113401 GBFD111101

Half Rate Speech Enumerati NO(No), System on Type YES(Yes) Informatio n Sending

Whether the downlink DTX function is enabled for half rate (HR) calls. This function is also restricted by the DTX switch in SET the MSC. HR Use GCELLB HRDLDT If the Downlink BSC6900 ASICPAR X MSC DTX A(Optiona allows the l) downlink DTX for calls and the value of this parameter (HRDLDT X) is YES, the downlink DTX is enabled for HR calls of cells. Whether

GBFD114801 GBFD113401 GBFD115502

Discontin uous Transmis sion Enumerati NO(No), (DTX) on Type YES(Yes) Downlink Half Rate Speech AMR HR

Load of UL-OL HRIUOLD Cells RATESEL Rate ALLOW Select Allowed

to enable the BSC to assign half or full rate channels SET to MSs GCELLC GBFDBSC6900 according HMGAD( 113201 to the Optional) channel seizure ratio in the overlaid and underlaid

Concentri Enumerati NO(No), c Cell on Type YES(Yes)

Whether the uplink DTX function is enabled for HR calls. For details, see GSM Rec. 05.08. Uplink DTX is not restricted SET by the GCELLB HRULDT HR Uplink MSC. If BSC6900 ASICPAR X DTX this A(Optiona parameter l) is set to May_Use, the MS can use DTX. If this parameter is set to Shall_Use or Shall_Not _Use, the MS cannot use DTX.

GBFD114803 GBFD113401 GBFD115502

Discontin May_Use( uous May Use), Transmis Shall_Use sion (Shall Enumerati (DTX) Use), on Type Uplink Shall_NO Half Rate T_Use(Sh Speech all not AMR HR Use)

HSN

HSN

Hopping sequence number (HSN), indicating 64 types of frequency hopping sequence s. If this parameter is set to 0, the frequency ADD hopping is GCELLM performe GBFDBSC6900 AGRP(Op d in 113701 tional) sequence . If this parameter is set to a value from 1 to 63, the frequency hopping is performe d in a pseudorandom manner, that is a Number

Frequenc y Hopping (RF Interval hopping, Type baseband hopping)

0~63

HSN

of the slot where the main board of ADD the RXU Head Slot BTSRXU chain or GBFDBSC6900 No. CHAIN(M ring is 111202 andatory) located. The slot No. is unique in the same BTS.

O&M of BTS

Interval Type

0~23

HSNSW

HSN ADD Modificati BSC6900 GCELL(O on Switch ptional)

HSRN

Head Subrack No.

ADD BTSRXU BSC6900 CHAIN(M andatory)

HT

ADD BTSBFD( Hop Type BSC6900 Mandator y)

Whether dynamic use of HSNs is enabled. If the functions of frequency hopping and Flex MAIO are enabled in a cell and the value of this parameter is ON, adjacentchannel interferen ce between channels can be Number of the subrack where the main board of the RXU chain or ring is located. The subrack No. is unique in the same BTS. Bidirectio nal Forwardin g Detection Hop Type.

GBFD117001

Flex MAIO

Enumerati OFF(Off), on Type ON(On)

GBFD111202

O&M of BTS

Interval Type

0~254

GBFD118609

SBFD(SI IP Fault NGLE_H Detection Enumerati OP), Based on on Type MBFD(M BFD ULTI_HO P)

HTCP

If the ambient temperatu re is higher than "High Temperat ure Critical Point", the temperatu re control system controls High SET the Temperat BTSDHE difference MRFDure BSC6900 UBP(Opti between 210304 Critical onal) the inlet Point and outlet temperatu res. In multimode scenario, the value of this parameter in one mode must be the same as the value of

Faulty Interval Managem Type ent

-99~70

HTDO

High SET Temperat BTSDHE BSC6900 ure Delta UBP(Opti Tout onal)

HTSDF

High SET Temperat BTSAPM ure BSC6900 UBP(Opti Shutdown onal) Flag

If the outlet temperatu re is higher than "High Temperat ure Critical Point" and the difference between the outlet temperatu re and ambient temperatu re reaches the value of this parameter , the temperatu re control system controls the difference between the inlet and outlet Whether to enable battery power-off against high temperatu re.

MRFD210304

Faulty Interval Managem Type ent

0~30

MRFD210304

DISABLE( Faulty DISABLE) Enumerati Managem , on Type ent ENABLE( ENABLE)

Enable ADD Humidity HUM_MA Humidity BSC6900 EMU(Opti alarm SK Alarm onal) switch Reporting

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

Upper HUM_TH Limit of D_HIGH Humidity Alarm

Lower HUM_TH Limit of D_LOW Humidity Alarm

Upper limit of humidity. When the ADD humidity BSC6900 EMU(Opti exceeds onal) the upper limit, a humidity alarm is reported. Lower limit of humidity. When the humidity ADD is lower BSC6900 EMU(Opti than the onal) lower limit, a humidity alarm is reported. When the

MRFD210304

Faulty String Managem Type ent

None

MRFD210304

Faulty String Managem Type ent

None

ambient humidity of the APMU is greater than the value of this parameter , the BTS reports an overhigh ambient humidity Upper SET alarm. HUMALA Threshold BTSAPM In multi- MRFDMRTHRE of BSC6900 UBP(Opti mode 210304 SHOLDH Humidity onal) scenario, Alarm the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode.

Faulty Interval Managem Type ent

0~1000

When the ambient humidity is greater than the value of this parameter , the BTS reports an overhigh ambient humidity alarm. Upper SET In multiHUMALA Threshold BTSDPM mode MRFDMRTHRE of BSC6900 UBP(Opti scenario, 210304 SHOLDH Humidity onal) the value Alarm of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode.

Faulty Interval Managem Type ent

0~1000

When the ambient humidity of the APMU is less than the value of this parameter , the BTS reports an overlow ambient humidity Lower alarm. SET HUMALA Threshold In multiBTSAPM MRFDMRTHRE of BSC6900 mode UBP(Opti 210304 SHOLDL Humidity scenario, onal) Alarm the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode.

Faulty Interval Managem Type ent

0~1000

When the ambient humidity is less than the value of this parameter , the BTS reports an overlow ambient humidity Lower alarm. SET HUMALA Threshold In multiBTSDPM MRFDMRTHRE of BSC6900 mode UBP(Opti 210304 SHOLDL Humidity scenario, onal) Alarm the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another Delay for which the SET BTS waits Hysteresi BTSAIRC GBFDBSC6900 to switch s for On ON(Optio 111202 on the air nal) conditione r

Faulty Interval Managem Type ent

0~1000

HYSON

O&M of BTS

Interval Type

1~30

Inactive IARXTMR RX timer

This timer is started after a connectio n is establishe d successfu SET lly. If a SCCPTM detection GBFDBSC6900 R(Optiona message 111804 l) is not received when this timer expires, the connectio n will be released. STR TRANSP Duration BSC6900 ERFTST( in IASU Mandator mode y)

A Interface Protocol Process

Interval Type

180~1260

IASUDUR Duration AT

GBFD111207

BTS Test Interval Function Type

1~60

IASUPOR Port No. T

Port number in IASU mode. For STR the TRANSP BTS3002 GBFDBSC6900 ERFTST( C, the 111202 Mandator port y) number cannot be set to "E1PORT 3".

O&M of BTS

Type of STR Transmis the TRANSP IASUSLC sion transmissi GBFDBSC6900 ERFTST( TTMU Board on board 111202 Mandator Type in IASU y) mode

O&M of BTS

E1PORT0 (E1 PORT0), E1PORT1 (E1 PORT1), E1PORT2 (E1 PORT2), Enumerati E1PORT3 on Type (E1 PORT3), OPTICAL PORT0(O PTICAL PORT0), OPTICAL PORT1(O PTICAL PORT1) MAINDO MU(MAIN DOMU), SLAVED OMU1(SL Enumerati AVE on Type DOMU1), SLAVED OMU2(SL AVE DOMU2)

Inactive IATXTMR TX timer

This timer is started after a connectio n is establishe d SET successfu SCCPTM GBFDBSC6900 lly. When R(Optiona 111804 this timer l) expires, a detection message will be sent to the peer end. Minimum

A Interface Protocol Process

Interval Type

60~600

C/I ratio that IBCA AMR FR services allow. An idle channel can be assigned to such a service only when the C/I ratio of IBCA SET the idle IBCAAFR AMR FR GCELLC channel is GBFDSOFTBLK BSC6900 Soft Block HMGAD( greater 117002 THRD Threshold Optional) than this threshold. In addition, a new call associate d with such a service can be establishe d only when the call does not decrease

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~23

Minimum C/I ratio that IBCA AMR HR services allow. An idle channel can be assigned to such a service only when the C/I ratio of IBCA SET the idle IBCAAHR AMR HR GCELLC channel is GBFDSOFTBLK BSC6900 Soft Block HMGAD( greater 117002 THRD Threshold Optional) than this threshold. In addition, a new call associate d with such a service can be establishe d only when the call does not decrease SET GCELLC BSC6900 HMGAD( Optional) Whether to enable GBFDthe IBCA 117002 algorithm

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~23

IBCAALL IBCA OWED Allowed

IBCA (Interfere nce Enumerati NO(No), Based on Type YES(Yes) Channel Allocation )

IBCAASS WAITME ASURER PTTIME

IBCA Assign Waiting Mr Time

Length of the timer for a new call to wait for the measure ment report (MR) on the signaling channel when dynamic SET measure GCELLC GBFDBSC6900 ment of HMGAD( 117002 the BA2 Optional) list is enabled during assignme nt. If this parameter is set to 0, dynamic measure ment of the BA2 list is not enabled during assignme

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~20

Number of measure ment reports sampled for averaging path loss. A single measure ment report may not reflect the SET IBCACAL IBCA Call actual GCELLC GBFDLINFOFIL Informatio BSC6900 network HMGAD( 117002 TERLEN n Filter situations Optional) accurately . Therefore , the BSC needs to average the measured values in several successiv e measure ment reports to

IBCA (Interfere nce Interval Based Type Channel Allocation )

1~4

IBCA SetIBCACAL SET up Call LSOFTBL GCELLC Soft Block BSC6900 OCKTHO HMGAD( Threshold FFSET Optional) Offset

Target IBCACAL SET CIR LTARGE GCELLC Offset of BSC6900 TCIROFF HMGAD( IBCA SetSET Optional) up Call

When the IBCA algorithm is enabled, this parameter is used to calculate the actual soft blocking threshold of an existing call. The formula is as follows: Actual soft blocking threshold of an existing call = Configure d soft blocking threshold of an existing call IBCA SetWhen the IBCA algorithm is enabled, this parameter is used to calculate the target CIR of an existing call. The formula is as follows: Target CIR of an existing call = Target CIR in use + Target CIR

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~14

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~14

Differenc e between uplink and downlink path losses, which is used to estimate the downlink path loss of a call when the IBCA SET downlink IBCADLP Downlink GCELLC path loss GBFDATHLOS BSC6900 Path Loss HMGAD( cannot be 117002 SOFF Offset Optional) computed directly according to a measure ment report. This parameter is configure d according to the combined loss and

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~63

Whether to measure the IBCA neighbor cells of the serving cell dynamical ly. If the dynamic measure ment is enabled, IBCADYN IBCA Dyn ADD when a CMEASU Measure G2GNCE call uses GBFDRENCEL BSC6900 Neighbou LL(Option a 117002 LALLOW r Cell Flag al) channel, ED the BSC sends the SACCH Modify message to modify the frequenci es in the BA2 table in System Informatio n 5, 5bis, and 5ter to the

IBCA (Interfere nce Enumerati NO(No), Based on Type YES(Yes) Channel Allocation )

IBCAEHO ASSWAIT MEASUR ERPTTIM E

IBCA Urgent HO Waiting Mr Time

Length of the timer for a call to measure the path loss in the neighbori ng cell with strong interferen ce of the target cell. The SET call to be GCELLC handed GBFDBSC6900 HMGAD( over 117002 Optional) needs to measure the path loss before initiating the handover to the target cell when dynamic measure ment of the BA2 list is

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~20

IBCA IBCAFLE Flexible XTSCALL TSC OWED Allowed

Whether the IBCA flexible TSC function is enabled. When this parameter is set to NO, the flexible TSC function is SET disabled GCELLC and the GBFDBSC6900 HMGAD( configure 117002 Optional) d TSC is used. When the BTS supports Flex TSC and this parameter is set to YES, the flexible TSC function is enabled.

IBCA (Interfere OFF(Not nce Enumerati Allowed), Based on Type ON(Allow Channel ed) Allocation )

Whether the IBCA forced BTS synchroni zation is allowed. When this parameter is set to YES, the synchroni zation procedure IBCA is IBCAFOR Forced SET performe CEDBTS BTS GCELLC d even GBFDBSC6900 SYNCALL Synchroni HMGAD( though 117002 OWED zation Optional) the BTSs Allowed are insynchro nous. When this parameter is set to NO, the existing procedure , either the synchroni zation procedure or the out-

IBCA (Interfere OFF(Not nce Enumerati Allowed), Based on Type ON(Allow Channel ed) Allocation )

Minimum C/I ratio that IBCA FR/EFR services allow. An idle channel can be assigned to such a service only when the C/I ratio of IBCA SET the idle IBCAFRS FR/EFR GCELLC channel is GBFDOFTBLKT BSC6900 Soft Block HMGAD( greater 117002 HRD Threshold Optional) than this threshold. In addition, a new call associate d with such a service can be establishe d only when the call does not decrease

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~23

Length of the timer for a call to wait for other valid MRs after receiving the first valid MR of the target cell if dynamic IBCAHOA measure IBCA HO SET SSWAIT ment of Waiting GCELLC GBFDMEASUR BSC6900 the BA2 Effective HMGAD( 117002 ERPTTIM list is Mr Time Optional) E enabled during handover. When this parameter is set to 0, the call does not wait for other MRs after receiving the first MR of the

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~20

SET IBCAHRS IBCA HR GCELLC OFTBLKT Soft Block BSC6900 HMGAD( HRD Threshold Optional)

IBCA IBCAICD ICDM MRELEV Initial OFFSET Level Offset

SET GCELLC BSC6900 HMGAD( Optional)

Minimum C/I ratio that IBCA HR services allow. An idle channel can be assigned to such a service only when the C/I ratio of the idle channel is greater than this threshold. In addition, a new call associate d with such a service can be establishe d only when the call does not decrease In the ICDM matrix algorithm, the signal strength (0-63) is divided into 10 levels. The signal strength that is smaller than or equal to the value of this parameter is at the

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~23

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~31

IBCAICD IBCA MSWITC ICDM H Switch

Whether to enable the ICDM algorithm for the cell. The ICDM algorithm helps to improve the SET precision GCELLC GBFDBSC6900 in HMGAD( 117002 estimating Optional) the path loss of an IBCA neighbor cell and to increase the efficiency of the IBCA algorithm.

IBCA (Interfere nce Enumerati NO(No), Based on Type YES(Yes) Channel Allocation )

Period of informatio n exchange between IBCA Info the BSC SET IBCAINB Report boards. OTHSOF GBFDSCINFOR Period BSC6900 The TPARA(O 117002 PTPRD Within informatio ptional) BSC n helps to estimate the C/I ratio for the IBCA algorithm.

IBCA (Interfere nce Interval Based Type Channel Allocation )

2~600

IBCA Init. IBCAINIT SET Power PCRXLE GCELLC Control BSC6900 VDLOFF HMGAD( RexLevD SET Optional) L Offset

IBCA Init. IBCAINIT SET Power PCRXLE GCELLC Control BSC6900 VULOFF HMGAD( RexLevU SET Optional) L Offset

Adds a specified offset to the downlink target receive level when power control algorithm III is used to calculate the initial transmit power of a BTS in the IBCA function Adds a specified offset to the uplink target receive level when power control algorithm III is used to calculate the initial transmit power of an MS in the IBCA function

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~63

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~63

Adds a specified offset to the downlink target receive quality when IBCAINIT IBCA Init. SET power PCRXQU Pwr Ctrl GCELLC GBFDBSC6900 control ALDLOFF Rx Qual HMGAD( 117002 algorithm SET DL Offset Optional) III is used to calculate the initial transmit power of a BTS in the IBCA function Adds a specified offset to the uplink target receive quality when IBCAINIT IBCA Init. SET power PCRXQU Pwr Ctrl GCELLC control GBFDBSC6900 ALULOFF Rx Qual HMGAD( algorithm 117002 SET UL Offset Optional) III is used to calculate the initial transmit power of an MS in the IBCA function

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~22

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~22

SET IBCAIUO IBCA IUO GCELLC PATHLO Path Loss BSC6900 HMGAD( SSOFF Offset Optional)

IBCA IBCAMAI MAIO OUSMTD Using Method

SET GCELLC BSC6900 HMGAD( Optional)

In an IUO cell (or a CoBCCH cell), the path loss of an MS to the serving cell or a neighbori ng cell measured on the underlay is used together with this parameter to estimate the path loss on the overlay. IUO path loss compens ation = Combiner insert loss difference + Path loss difference Determin es the MAIO selection method for each timeslot. The Optimal MAIO policy selects the optimal MAIO being evaluated , while the Random MAIO policy randomly selects a MAIO out of qualified

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~63

GBFD117002

IBCA 0(Max. (Interfere optimized nce Enumerati MAIO), Based on Type 1(Rando Channel mization Allocation MAIO) )

The IBCA interferen ce evaluation process only considers the interferen ce of the IBCA strongest SET IBCAMAX Max. N existing GCELLC GBFDINTFSRC Interferen BSC6900 calls on HMGAD( 117002 NUM ce Source the newlyOptional) Num. establishe d call being evaluated . This parameter correspon ds to the abovementione d N. Indicates whether this neighbori ng cell is the IBCA neighbori ng cell of the serving cell. That is, when a cell is configure ADD IBCA d as the IBCANCE G2GNCE GBFDNeighbor BSC6900 neighbori LLFLAG LL(Option 117002 Cell Flag ng cell of al) the serving cell, whether the IBCA algorithm considers the interferen ce between the serving cell and

IBCA (Interfere nce Interval Based Type Channel Allocation )

5~40

IBCA (Interfere nce Enumerati NO(No), Based on Type YES(Yes) Channel Allocation )

IBCA IBCANCE Pathloss LLPATHL Est of OSSESTI Non. MR MATE Ncell

SET GCELLC BSC6900 HMGAD( Optional)

Target IBCANE SET CIR WCALLCI GCELLC Offset of BSC6900 ROFFSE HMGAD( IBCA T Optional) New Call

Estimates the receive level of the unmeasur ed IBCA neighbori ng cells. When a consecuti ve "IBCA Non Measure ment Ncell Stat. Num" measure ment reports cover less than six neighbori ng cells (or the number of the reported neighbori ng cells is smaller than that of the actually When the IBCA algorithm is enabled, this parameter is used to calculate the target CIR of a new call. The formula is as follows: Target CIR of a new call = Target CIR in use + Target CIR

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~63

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~30

IBCANHO ASSWAIT MEASUR ERPTTIM E

IBCA Natural HO Waiting Mr Time

Length of the timer for a call to measure the path loss in the neighbori ng cell with strong interferen ce of the target cell. The SET call to be GCELLC handed GBFDBSC6900 HMGAD( over 117002 Optional) needs to measure the path loss before initiating the handover to the target cell when dynamic measure ment of the BA2 list is

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~20

Estimates the receive level of the unmeasur ed IBCA neighbori ng cells. When a consecuti ve "IBCA Non Measure ment IBCA Non IBCANON SET Ncell Stat. Measure MEANCE GCELLC Num" GBFDment BSC6900 LLSTATN HMGAD( measure 117002 Ncell Stat. UM Optional) ment Num reports cover less than six neighbori ng cells (or the number of the reported neighbori ng cells is smaller than that of the actually

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~16

When the IBCA algorithm is enabled and the HSN is not 0, the IBCA priority and the SDCCH/P DCH priority Corrected SET are IBCAOPR Factor of GCELLC divided by GBFDREVISEF BSC6900 IBCA HMGAD( this 117002 ACTOR Priority Optional) corrected factor respective ly to reduce the weight of IBCA priority. In addition, the priority of the interferen ce band is

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~63

Specifies a period during which the inter-BSC informatio n IBCA Info exchange SET IBCAOUT Report must be OTHSOF GBFDBSCINFO Period BSC6900 complete TPARA(O 117002 RPTPRD Between d. The ptional) BSC informatio n is mainly used by IBCA for C/I ratio estimation .

IBCA (Interfere nce Interval Based Type Channel Allocation )

2~600

IBCAPAT IBCA HLOSSO Pathloss FF Offset

When the path loss of an MS to a neighbori ng cell cannot be measured based on the SET existing GCELLC measure GBFDBSC6900 HMGAD( ment 117002 Optional) results, it is estimated based on the path loss of the MS to the serving cell plus the IBCA path loss Considers

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~50

the influence of history path loss informatio n during the calculatio n of the ICDM algorithm path loss. The smaller IBCA SET IBCAPLFI the Path Lose GCELLC GBFDLTFACTO BSC6900 filtering Filter HMGAD( 117002 R coefficient Factor Optional) , the smaller the influence of history path loss; on the other hand, the larger the filtering coefficient , the larger the influence

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~10

IBCARXL IBCA EVOFFS RxLev ET Offset

Estimates the receive level of the unmeasur ed IBCA neighbori ng cells. When a consecuti ve "IBCA Non Measure ment ADD Ncell Stat. G2GNCE Num" GBFDBSC6900 LL(Option measure 117002 al) ment reports cover less than six neighbori ng cells (or the number of the reported neighbori ng cells is smaller than that of the actually Use this parameter when the path loss of an MS to serving SET cells GCELLC GBFDBSC6900 cannot be HMGAD( 117002 measured Optional) based on the existing measure ment results

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~63

IBCA IBCASCE Service LLPATHL Cell OSS Pathloss

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~160

IBCA Soft SET IBCASOF Block GCELLC TBLKSAI BSC6900 SAIC HMGAD( COFF Offset Optional)

SET IBCASOF IBCA Soft GCELLC TBLKSWI Block BSC6900 HMGAD( TCH Switch Optional)

MSs that support SAIC can tolerate a lower carrier-tointerferen ce ratio. This variable indicates the downward adjustme nt step of the soft blocking threshold of SAIC MSs. Whether to deny the access of a call when none of the MAIO evaluation results meets the C/I ratio requireme nt of the call during channel assignme

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~23

GBFD117002

IBCA (Interfere nce Enumerati NO(No), Based on Type YES(Yes) Channel Allocation )

Whether the handover of the calls on the single channels is allowed (single channels are the two halfrate subchannels on a IBCASUB IBCA SubSET timeslot, CHNHAN Channel GCELLC in which GBFDBSC6900 DOVERA Handover HMGAD( only one 117002 LLOWED Allowed Optional) is in the occupied state) when single channels are to be adjusted to a fullrate channel. When this parameter is set to ON, the handover Whether a MAIO meets the access requireme nt. When the C/I ratio of a IBCA SET IBCATAR MAIO is MAIO GCELLC GBFDGETCIRT BSC6900 higher Target C/I HMGAD( 117002 HRSH than this Threshold Optional) threshold, the MAIO can be assigned to the call being processe d.

IBCA (Interfere OFF(Not nce Enumerati Allowed), Based on Type ON(Allow Channel ed) Allocation )

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~63

Whether to enable the IBCA SET algorithm IBCAUSE IUO IBCA GCELLC for the GBFDDIUOSUB BSC6900 Allowed HMGAD( overlay 117002 LAY Optional) and underlay of an IUO cell

Whether a single IBCA MS can dynamical ly measure the neighbori ng cells. When this parameter is set to YES, the neighbori IBCA IBCAUSR SET ng cells User Dyn DYNCME GCELLC where GBFDMeasure BSC6900 ASUREN HMGAD( "IBCA 117002 Neighbor CELL Optional) Dynamic Cell Measure Neighbor Cell Flag" is set to YES are dynamical ly measured . Dynamic measure ment on neighbori ng cells is mutually exclusive

NO(Disab led in OL and UL subcell), UNDER(E IBCA nabled in (Interfere UL nce Enumerati subcell), Based on Type INNER( Channel Enabled Allocation in OL ) subcell), YES(Ena bled in OL and UL subcell)

IBCA (Interfere nce Enumerati NO(No), Based on Type YES(Yes) Channel Allocation )

The lowest C/I ratio that can be tolerated by IBCA WAMR FR. The C/I ratio of an idle channel must be larger than this parameter IBCA IBCAWA SET . WAMR FRSOFT GCELLC Otherwise GBFDFR Soft BSC6900 BLKTHR HMGAD( , it cannot 117002 Block D Optional) be Threshold assigned. In addition, the system does not allow a newlyestablishe d call causing the C/I ratio of existing calls to be

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~23

ICBALLO ICB W Allowed

This parameter is used to enable the Intelligent Combiner Bypass (ICB) function on the BCCH TRX of a cell. This SET parameter GCELLB specifies GBFDBSC6900 ASICPAR whether 111604 A(Optiona to allow l) the cell to enable the ICB function. When this parameter is set to YES, the TCHs on the nonBCCH TRX are preferenti ally assigned.

NO(NO), Intelligent YES(YES Enumerati Combiner ), on Type Bypass NULL(NU LL)

ICF

Whether to enable the intelligent control of the diesel engine. If this parameter is set to ENABLE, the PMU will SET Intelligent control BTSAPM GBFDControl BSC6900 the diesel UBP(Opti 111202 Flag engine onal) automatic ally according to the settings of the parameter s to save the energy. This parameter is set to ICMP packet length. It is the total ADD length of GBFDBSC6900 IPPATH( the ICMP 118605 Optional) packet containing the IP header. DSCP correspon ding to SET the BSCPST interactio GBFDBSC6900 CDSCPM n service 118603 AP(Optio with the nal) THP level of PRIORIT Y1

O&M of BTS

DISABLE( DISABLE) Enumerati , on Type ENABLE( ENABLE)

ICMP ICMPPKG packet LEN Length

IP QOS

Interval Type

44~1024

DSCP of ICTHP1D PRI.1 SCP INTACT[ QoS]

Gb over IP

Interval Type

0~63

DSCP of ICTHP2D PRI.2 SCP INTACT[ QoS]

DSCP correspon ding to SET the BSCPST interactio GBFDBSC6900 CDSCPM n service 118603 AP(Optio with the nal) THP level of PRIORIT Y2 DSCP correspon ding to SET the BSCPST interactio GBFDBSC6900 CDSCPM n service 118603 AP(Optio with the nal) THP level of PRIORIT Y3 ADD SCHTSK( Mandator y) SET SCHTSK Number SW(Optio of the GBFDBSC6900 nal) scheduled 111203 ADD task SUBTSK( Optional) ADD SUBCMD (Optional) Number STR of the GBFDBSC6900 SCHTSK( scheduled 111203 Optional) task

Gb over IP

Interval Type

0~63

DSCP of ICTHP3D PRI.3 SCP INTACT[ QoS]

Gb over IP

Interval Type

0~63

ID

Task ID

O&M of BSC

Interval Type

1~30

ID

Task ID

O&M of BSC

Interval Type

1~30,100 ~32767

ID

Index

Threshold index. This parameter uniquely identifies the verificatio n threshold of the transmit bandwidth (specified by ADD "Forward BTSBRD Bandwidt GBFDBSC6900 CAP(Man h"), 111202 datory) receive bandwidth (specified by "Receive Bandwidt h"), and number of TRXs (specified by "TRX Number") of TRX boards of a type in one This

O&M of BTS

Interval Type

0~65535

parameter indicates the idle code of the A SET interface. GBFDIdle_Code Idle Code BSC6900 TCPARA( It is used 118602 Optional) for the interconn ection of the A interfaces .

A over IP

Interval Type

0~255

SET IDLECOD IDLE Idle code BSC6900 E1T1LOP E code (Optional)

None

None

Interval Type

0~255

When the number of idle SDCCH channels in a cell is smaller than this SET Idle parameter GCELLC IDLESDT SDCCH , the GBFDBSC6900 HMGBASI HRES Threshold system 113001 C(Optiona N1 searches l) for available TCHs and transform s them into SDCCH channels.

SDCCH Dynamic Interval Adjustme Type nt

0~63

IDTYPE

Index Type

SET BTSEXC URSION( Mandator y) ADD EXTNCE LL(Manda GBFDBSC6900 Index type tory) 111202 SET BSCSYN COFF(Ma ndatory) SET BTSAISS( Mandator ADD BTSESN( Mandator BTS index y) BSC6900 None type SET BSCABIS PRIMAP( Mandator

O&M of BTS

BYIDX(By Enumerati Index), on Type BYNAME( By Name)

IDTYPE

BTS Index Type

None

BYNAME( By Enumerati Name), on Type BYID(By Index)

IDTYPE

Index Type

ADD GCELLF REQ(Man datory) ADD GCELLM AGRP(Ma ndatory) ADD GCELLO SPMAP( Mandator y) SET GCELLA MRQUL( Mandator Type of BSC6900 an index y) SET GCELLB ASICPAR A(Mandat ory) SET GCELLC CAD(Man datory) SET GCELLC CTMR(M andatory) SET GCELLC CUTRAN

MRFD210301

BYNAME( Configura By tion Enumerati Name), Managem on Type BYID(By ent Index)

IDTYPE

Index Type

ADD G2GNCE MRFDBSC6900 Index type LL(Manda 210301 tory)

BYNAME( Configura By name), tion Enumerati BYID(By Managem on Type index), ent BYCGI(By CGI) BYNAME( MBSC By Enumerati Load Name), on Type Balancing BYID(By Index)

IDTYPE

Index Type

SET GCELLH Type of BSC6900 OINTERR an index ATLDB(M andatory)

MRFD211402

IDTYPE

Index Type

ADD PTPBVC( Mandator y) SET GCELLE GPRSPA RA(Mand atory) SET GCELLP RACH(Ma ndatory) SET GCELLP RIVATEO PTPARA( BSC6900 Mandator y) SET GCELLP SBASE(M andatory) SET GCELLP SCHM(M andatory) SET GCELLP SCS(Man datory) SET GCELLP SI1(Mand

Subscribe rs can specify the cell MRFDaccording 210301 to the index or the name.

BYNAME( Configura By tion Enumerati Name), Managem on Type BYID(By ent Index)

IDTYPE

Index Type

SET BTSFMU ABP(Man datory) SET BTSNFC BBP(Man datory) SET BTSPMU BP(Mand atory) SET BTSAPM UBP(Man datory) SET BSC6900 BTSDAT UBP(Man datory) SET BTSDEM UBP(Man datory) SET BTSDFC UBP(Man datory) SET BTSDHE UBP(Man datory) SET BTSDOM

Index type of the BTS. BYNAME: query by GBFDBTS 111202 name; BYID: query by BTS index.

O&M of BTS

BYNAME( By Enumerati Name), on Type BYID(By Index)

SET BTSSHA RING(Ma ndatory) ADD BTSSFP MODE(M andatory) SET BTSFOR BIDTS(M andatory) SET BTSIDLE TS(Mand atory) Index SET IDTYPE BSC6900 Type BTSOML TS(Mand atory) TID BTSABIS TS(Mand atory) ADD BTSIPRT( Mandator y) SET BTSETH PORT(Ma ndatory) SET BTSRING ADD Semiperm SEMILIN IDX anent BSC6900 K(Mandat Link Index ory) SET MSTOCE LL(Manda tory) TST Index SNDRSI( IDXTYPE BSC6900 Type Mandator y) TST UPDMSR AC(Mand atory)

Index type. BYNAME: query by GBFDname; 111202 BYID: query by index.

O&M of BTS

BYNAME( By Enumerati Name), on Type BYID(By Index)

Index of the GBFDsemiperm 114701 anent link

SemiPermane Interval nt Type Connectio n

0~255

Support the index based on MRFDthe TLLI 210301 and IMSI mode

Configura BYTLLI(B tion Enumerati y TLLI), Managem on Type BYIMSI(B ent y IMSI)

Index IDXTYPE Type

Index type, SET supportin PSCELLT g the GBFDBSC6900 ODSP(Ma index 111203 ndatory) based on the cell and BSC

O&M of BSC

BYCELL( Enumerati By Cell), on Type BYBSC(B y BSC)

Whether the handshak e mechanis m is enabled at the Cb interface. Currently, the BSC6900 and the CBC communi ADD cations If CB IFCBSHA GCBSAD through GBFDShake BSC6900 KEHAND DR(Optio the 113601 Hand nal) TCP/IP protocol. Thus, the BSC6900 may not detect communi cation link disconnec tion in some cases. The handshak e mechanis ADD BTSIPRT( Number Mandator Outgoing of the GBFDy) IFNO Interface BSC6900 outgoing 111202 IMP No. interface BTSIPRT( of a link Mandator y) Whether to set the middle SET Positive frequency IFOFFSE BTSRXU GBFDor Minus BSC6900 offset to THIG BP(Optio 111202 Offset positive nal) offset or minus offset Indication offset in SET the IFOFFSE Indication BTSRXU middle GBFDBSC6900 TLOW Offset BP(Optio frequency 111202 nal) offset configurat ion

Short Message Service Enumerati YES(Yes) Cell on Type , NO(No) Broadcast (TS23)

O&M of BTS

Interval Type

0~15

O&M of BTS

Positive(P Enumerati ositive), on Type Minus(Mi nus)

O&M of BTS

Interval Type

0~125

Report IFREPPR Process O Flag

STR BTSLOG( Optional) BSC6900 ULD BTSLOG( Optional)

IGNORE MRNUM

Ignore Measure ment Report Number

SET GCELLH BSC6900 OFAST(O ptional)

IMEI

IMEI

CHK INNSPCH (Mandator y) STR CALLRES Value of BSC6900 LOP(Man an IMEI datory) ADD GCSCHR USER(Ma ndatory)

Whether to report the progress. "NO" indicates that the progress is not reported. "YES" indicates that the progress is Number of invalid measure ment reports allowed when the BSC6900 filters the measure ment reports. When the number of received measure ment reports is no larger than this parameter , the BSC does not perform filtering or make quick handover

GBFD111202

O&M of BTS

NO(Not Enumerati Report), on Type YES(Nee d Report)

GBFD510102

Fast Interval Move Type Handover

0~32

GBFD111203

O&M of BSC

String Type

None

Timer for the BSC6900 waiting for a CC message IMM ASS SET after IMMASSA A IF GCELLT sending a INTERFTI BSC6900 Creation MR(Optio CR MER Timer nal) message. If the timer expires, the seized SDCCH is released. The channel activation and immediat e assignme nt message Immediat SET s are sent e GCELLB at the IMMASS Assignme BSC6900 ASICPAR same CBB nt A(Optiona time to Optimized l) accelerat e the signaling processin g, thus increasing the response speed of the

GBFD111804

A Interface Protocol Process

Interval Type

1000~300 00

GBFD110502

Assignme nt and NO(NO), Immediat Enumerati YES(YES e on Type ) Assignme nt

This parameter specifies whether to support the takeover of the packet immediat e assignme nt by the BTS. It is Move relative to SET Immediat the uplink GCELLP IMMASS e immediat GBFDBSC6900 SOTHER DLSHIFT Assignme 119202 e PARA(Op nt Down assignme tional) to BTS nt. To improve the access rate of the MS, the BSS allocates the uplink TBF resources to the BTS in advance. The BTS

Packet NO(Not Assignme Enumerati Support), nt Taken on Type YES(Sup Over by port) the BTS

Whether to allow immediat e TCH assignme nt. If this parameter is set to YES, the BSC can assign a TCH immediat ely when there is TCH SET no Immediat GCELLB IMMASSE available GBFDe BSC6900 ASICPAR N SDCCH 110502 Assignme A(Optiona for a nt l) channel request. If this parameter is set to NO, the BSC can assign only an SDCCH when processin ga channel access

Assignme nt and Immediat Enumerati NO(No), e on Type YES(Yes) Assignme nt

Max SET IMMASS Delay of GCELLC MAXDEL IMM ASS BSC6900 CTMR(Op AYTIME Retransmi tional) t

Max SET IMMASS Transmit GCELLC MAXSEN BSC6900 Times of CTMR(Op DNUM IMM ASS tional)

Maximum time delay in resending an immediat e assignme nt message. Within the period specified by this parameter , an immediat e assignme nt message can be dispatche d and retransmit ted. Otherwise , the message is not dispatche Maximum number of retransmi ssions of an immediat e assignme nt message. When the value of this parameter is reached, the immediat e assignme nt message is not retransmit ted even if the value of

GBFD110502

Assignme nt and Immediat Interval e Type Assignme nt

0~254

GBFD110502

Assignme nt and Immediat Interval e Type Assignme nt

1~5

Whether the BSC6900 sends Use IMM immediat ASS SET IMMASS e Retransmi GCELLC GBFDRESEND BSC6900 assignme t CTMR(Op 110502 EN nt Paramete tional) retransmi r ssion parameter s to the BTS Whether to assign channels according to the access_d elay value in channel request message s during immediat e channel assignme nt When the access_d elay value in the channel request message is smaller than this parameter , the overlay channels are assigned preferenti ally; otherwise, the underlay channels are assigned preferenti ally.

Assignme nt and Immediat Enumerati NO(No), e on Type YES(Yes) Assignme nt

TA Pref. SET IMMASST of ImmeGCELLH BSC6900 AALLOW Assign OIUO(Opt Allowed ional)

GBFD113201

Concentri Enumerati NO(No), c Cell on Type YES(Yes)

TA SET Threshold IMMASST GCELLH of Imme- BSC6900 ATHRES OIUO(Opt Assign ional) Pref

GBFD113201

Concentri Interval c Cell Type

0~255

Whether Immediat to adjust e Initial the offset ADD IMMFNA Adjust time BSC6900 AISSCFG D After Site immediat (Optional) Reset ely after Enable the BTS is reset Timer carried by the Wait Indication informatio n element when the BSC6900 sends an immediat e assignme nt reject message SET IMMREJ to an MS. GCELLT WAITIND T3122 BSC6900 After the MR(Optio TIMER MS nal) receives the immediat e assignme nt reject message, the MS reattempt s to access the network after the CHK INNSPCH (Mandator y) STR CALLRES Value of IMSI IMSI BSC6900 LOP(Man an IMSI datory) ADD GCSCHR USER(Ma ndatory)

GBFD118201

SoftNO(NO), Synchroni Enumerati YES(YES zed on Type ) Network

GBFD110502

Assignme nt and Immediat Interval e Type Assignme nt

0~255

GBFD111203

O&M of BSC

String Type

None

IMSI

IMSI

Timer for the BSC6900 waiting for a handover complete message after sending a handover SET request INBSCHO GCELLT T3121 BSC6900 acknowle TIMER MR(Optio dgment nal) message in 2G/3G handover or interBSC handover. If the timer expires, a Clear REQ Threshold for fine tuning the BTS clock. If the offset Fine ADD of the INCHLOD Tuning BSC6900 AISSCFG BTS clock Threshold (Optional) is smaller than the threshold, no fine tuning is performe

SET MSTOCE LL(Manda tory) TST SNDRSI( Mandator y) BSC6900 TST UPDMSR AC(Mand atory) ADD GPSCHR USER(Ma ndatory)

Internatio nal mobile subscribe r identity of the MS. GBFDIMSI 114101 containing the number 0 to 9.

GPRS

String Type

None

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

500~6000 0

GBFD118201

SoftSynchroni Interval zed Type Network

0~8

Fine Tuning INCHPRD Period in BSC

Fine ADD tuning BSC6900 AISSCFG period in (Optional) the BSC

GBFD118201

SoftSynchroni Interval zed Type Network

1~30

INCLUDE Included ANG Angle

Included angle formed by the major lobe azimuths of the antennas in two cells SET under one GCELLLC BTS. A GBFDBSC6900 S(Optiona major 115402 l) lobe azimuth is measured from the due north to the direction of the cell antenna in a clockwise Number ADD of the inBTSCON GBFDBSC6900 port NECT(Op 111202 cabinet tional) on a BTS

BSSBased Interval LCS (Cell Type ID + TA)

0~360

INCN

In Port Cabinet No.

O&M of BTS

Interval Type

0~62

INDEN3

SET Independ BTSDOM ent E1 BSC6900 UBP(Opti Port 3 onal)

SET Intracell FINFHHOL GCELLH H HO BSC6900 AST OBASIC( Last Time Optional)

Whether to separate E1 from other optical fibers for the use of other devices. If this parameter is set to YES, other BTSs can connect to the BSC6900 through the independ ent E1 port 3 of the The triggering of intracell F-H handover s must meet the P/N criteria, that is, when the condition for intracell F-H handover s is met for P seconds during N seconds, an intracell F-H handover is triggered. This parameter correspon ds to the

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD115504

AMR FR/HR Interval Dynamic Type Adjustme nt

1~32

The triggering of intracell F-H handover s must meet the P/N criteria, that is, when the condition for intraSET Intracell Fcell F-H INFHHOS GCELLH GBFDH HO Stat BSC6900 handover TAT OBASIC( 115504 Time s is met Optional) for P seconds during N seconds, an intracell F-H handover is triggered. This parameter correspon ds to the ADD Info INFOEXC GNRNC( Exchange BSC6900 HGLIST Mandator Content y) Informatio n exchange MRFDcontent to 211402 be supported

AMR FR/HR Interval Dynamic Type Adjustme nt

1~32

MBSC Bit Field Load Type Balancing

CELLCAP CLASS, NACCRE LATED

INFRA_R Infrared ED_MAS alarm K switch

ADD Infrared BSC6900 EMU(Opti alarm onal) switch

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

SET INHOF2H F2H HO GCELLH BSC6900 TH Threshold OBASIC( Optional)

SET INHOH2F H2F HO GCELLH BSC6900 TH Threshold OBASIC( Optional)

For an AMR call, if the currently occupied channel is a full rate channel and the value of the Radio Quality Indication (RQI) in measure ment report divided by 2 is always higher than the threshold set by this parameter , an intracell F-H handover For an AMR call, if the currently occupied channel is a half rate channel and the value of the Radio Quality Indication (RQI) in measure ment report divided by 2 is always lower than the threshold set by this parameter , an intracell H-F handover

GBFD115504

AMR FR/HR Interval Dynamic Type Adjustme nt

0~39

GBFD115504

AMR FR/HR Interval Dynamic Type Adjustme nt

0~39

INHOPW ROVERL OADTHR ESHOLD

Power SET Overload GTRXDE BSC6900 Threshold V(Optiona In Ho. In l)

AMR INITCDM Starting DF Mode[F]

SET GCELLC BSC6900 CAMR(O ptional)

Power overload threshold for triggering incoming handover to the TRX under the prerequisi te that the power amplifier of the TRX provides the maximum output Initial coding mode used for full rate AMR calls. The four values 0, 1, 2, and 3 of this parameter respective ly represent the lowest, low, high, and highest coding rates in the ACS. This parameter does not take effect in A over IP mode. In A over IP mode, the TC is integrated

GBFD111005

Enhanced Channel Interval Assignme Type nt Algorithm

0~50

GBFD115501

AMR FR

Interval Type

0~3

AMR INITCDM Starting DH Mode[H]

Initial coding mode used for half rate AMR calls. The four values 0, 1, 2, and 3 of this parameter respective ly represent SET the GCELLC lowest, GBFDBSC6900 CAMR(O low, high, 115502 ptional) and highest coding rates in the ACS. This parameter does not take effect in A over IP mode. In A over IP mode, the TC is integrated

AMR HR

Interval Type

0~3

Initial coding mode used for broadban d AMR calls. The three values 0, AMR SET 1 and 2 of INITCDM Starting GCELLC this GBFDBSC6900 DWB Mode[WB CAMR(O parameter 115507 ] ptional) respective ly represent the lowest, low and highest coding rates in the ACS.

WB AMR

Interval Type

0~2

INMASK

In BSC Mask

Specifies ADD the SEMILIN GBFDBSC6900 timeslot K(Optiona 114701 mask in l) BSC6900

SemiPermane Bit Field nt Type Connectio n

TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

Whether to assign channel requests in the overlay subcell to the underlay subcell according to "UL Subcell Lower OL Load SET Subcell Threshold GCELLH INNASSO Assignme GBFD". If the BSC6900 OEDBPA PTEN nt 114402 load of RA(Optio Optimizati the nal) on underlay subcell is lower than "UL Subcell Lower Load Threshold ", incoming calls in the overlay subcell will be SET Inner Cell INNCELL GCELLH EDGE EDGEHO BSC6900 OEDBPA HO EN RA(Optio Enable nal) Whether to allow underlayGBFDto-overlay 114402 edge handover s

Enhanced DualEnumerati NO(No), Band on Type YES(Yes) Network

Enhanced DualEnumerati NO(No), Band on Type YES(Yes) Network

ADD BSC Index of INNCELLI EXTNCE MRFDInner Cell BSC6900 the cell in D LL(Manda 210301 Index the BSC tory)

Configura tion Interval Managem Type ent

0~2047

ADD BSC Name of INNCELL EXTNCE MRFDInner Cell BSC6900 the cell in NAME LL(Manda 210301 Name the BSC tory)

Configura tion String Managem Type ent

None

Whether Load HO SET to allow of OL GCELLH underlayINNLOAD GBFDSubcell to BSC6900 OEDBPA to-overlay HOEN 114402 UL RA(Optio load Subcell nal) handover s Overlaytounderlay load handover SET s are GCELLH performe GBFDBSC6900 OEDBPA d by 114402 RA(Optio levels. nal) This parameter indicates the duration

Enhanced DualEnumerati NO(No), Band on Type YES(Yes) Network

OL Subcell INNLOAD Load HOPERI Diversity HO Period

Enhanced DualInterval Band Type Network

1~255

Level step during Step SET overlay-toLength of GCELLH INNLOAD underlay GBFDOL BSC6900 OEDBPA HOSTEP hierarchic 114402 Subcell RA(Optio al load Load HO nal) handover s

Enhanced DualInterval Band Type Network

0~63

SET Inner Cell INNSERI GCELLH Serious OVERLD BSC6900 OEDBPA OverLoad THRED RA(Optio Thred nal)

INPN

In BSC Port No.

ADD SEMILIN BSC6900 K(Mandat ory)

In an enhanced dual-band network, if the load of the overlay subcell is higher than this parameter , the system cannot initiate an underlayto-overlay Incoming BSC6900 port number

GBFD114402

Enhanced DualInterval Band Type Network

0~100

GBFD114701

SemiPermane Interval nt Type Connectio n

0~335

INPN

BTS In Port No.

ADD Number BTSCON BSC6900 of a BTS NECT(Ma port ndatory)

GBFD111202

O&M of BTS

Interval Type

0~23

INPORTN DXX In O Port No.

ADD DXXTSE In-port GBFDBSC6900 XGRELA number of 111203 TION(Ma a DXX ndatory)

O&M of BSC

Interval Type

0~15

Mode of inputting Latitude SET the and GCELLLC latitude GBFDINPUTMD Longitude BSC6900 S(Optiona and 115402 Input l) longitude Mode of a cell location

Degree(D BSSegree), Based Enumerati D_min_se LCS (Cell on Type c(Degree ID + TA) Minute Second)

Whether Inter-BSC SET to allow INRBSCS SDCCH GCELLH inter-BSC GBFDBSC6900 DHOEN HO OCTRL(O SDCCH 110608 ALLowed ptional) handover s

SDCCH Enumerati NO(No), Handover on Type YES(Yes)

INSN

In BSC Slot No.

ADD SEMILIN BSC6900 K(Mandat ory)

Incoming BSC6900 GBFDslot 114701 number

SemiPermane Interval nt Type Connectio n

0~27

INSN

In Port Slot No.

ADD BTSCON BSC6900 NECT(Op tional)

Number of the in- GBFDport slot 111202 on a BTS

O&M of BTS

Interval Type

0~23

INSRN

In BSC Subrack No.

ADD SEMILIN BSC6900 K(Mandat ory)

Incoming BSC6900 GBFDsubrack 114701 number

SemiPermane Interval nt Type Connectio n

0~11

INSRN

In Port Subrack No.

Number ADD of the inBTSCON GBFDBSC6900 port NECT(Op 111202 subrack tional) on a BTS

O&M of BTS

Interval Type

0~254

INT

Time interval ADD for Broadcast GSMSCB sending a GBFDBSC6900 Interval (Mandator simple 113602 y) cell broadcast message

Simplified Interval Cell Type Broadcast

2~3600

Hysteresi s value during the handover s between cells on different Adjacent ADD layers or Cell InterINTELEV G2GNCE of layer HO BSC6900 HOHYST LL(Option different Hysteresi al) priorities. s This value is used to suppress inter-layer ping-pong handover s.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~127

Type of an interferen ce band statistics algorithm used when the frequency scanning function is Interfere SET enabled. INTERBA Band Stat GCELLS The GBFDNDSTAT BSC6900 Algorithm OFT(Opti interferen 112401 ALGO Type onal) ce band statistics algorithm I uses pair average, and the interferen ce band statistics algorithm II uses

INTBANI(I Cell Enumerati NTBANI), Frequenc on Type INTBANII( y Scan INTBANII)

Hysteresi s value during the handover s between Inter-cell ADD cells, This INTERCE HO G2GNCE BSC6900 value is LLHYST Hysteresi LL(Option used to s al) suppress ping-pong handover s between cells.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~127

Penalty INTERFE Time on REHOPE Interfere NTIME HO

Specifies an interval between SET two GCELLH BSC6900 consecuti OFITPEN ve (Optional) interferen ce handover s

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

The triggering of interferen ce handover s must meet the P/N criteria, that is, when P out of N measure ment SET INTERFE Interfere reports GCELLH GBFDRELASTT HO Valid BSC6900 meet the OBASIC( 510501 IME Time condition Optional) for interferen ce handover s, a concentric circle handover is triggered. This parameter correspon ds to the P in the

HUAWEI Interval II Type Handover

1~16

The triggering of interferen ce handover s must meet the P/N criteria, that is, when P out of N measure ment SET INTERFE Interfere reports GCELLH GBFDRESTATT HO Static BSC6900 meet the OBASIC( 510501 IME Time condition Optional) for interferen ce handover s, a concentric circle handover is triggered. This parameter correspon ds to the N in the

HUAWEI Interval II Type Handover

1~16

Whether to allow the interferen ce handover algorithm. Interferen ce handover s are triggered when the receive level is SET higher Interferen INTERFH GCELLH than the ce HO BSC6900 OEN OBASIC( receive Allowed Optional) threshold while the transmit quality is lower than the interferen ce handover quality threshold, that is, when the MSs are subject to all kinds Whether

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

Interf. INTERFP Priority RIALLOW Allowed

to consider SET interferen GCELLC GBFDBSC6900 ce HMGAD( 111005 priorities Optional) during channel assignme

Enhanced Channel Enumerati NO(No), Assignme on Type YES(Yes) nt Algorithm

Threshold used for interferen ce measure ment. The BSS measures the uplink quality of the radio channels occupied by MSs, and Interferen SET calculates INTERFT ce Band GCELLO and BSC6900 HRES0 Threshold THEXT(O reports 0 ptional) the interferen ce on each of the idle channels. This helps the BSC6900 to assign channels. According to the strength of interferen

GBFD111001 GBFD111005

TRX Managem ent Enhanced Interval Channel Type Assignme nt Algorithm

48~115

Threshold used for interferen ce measure ment. The BSS measures the uplink quality of the radio channels occupied by MSs, and Interferen SET calculates INTERFT ce Band GCELLO and BSC6900 HRES1 Threshold THEXT(O reports 1 ptional) the interferen ce on each of the idle channels. This helps the BSC6900 to assign channels. According to the strength of interferen

GBFD111001 GBFD111005

TRX Managem ent Enhanced Interval Channel Type Assignme nt Algorithm

48~115

Threshold used for interferen ce measure ment. The BSS measures the uplink quality of the radio channels occupied by MSs, and Interferen SET calculates INTERFT ce Band GCELLO and BSC6900 HRES2 Threshold THEXT(O reports 2 ptional) the interferen ce on each of the idle channels. This helps the BSC6900 to assign channels. According to the strength of interferen

GBFD111001 GBFD111005

TRX Managem ent Enhanced Interval Channel Type Assignme nt Algorithm

48~115

Threshold used for interferen ce measure ment. The BSS measures the uplink quality of the radio channels occupied by MSs, and Interferen SET calculates INTERFT ce Band GCELLO and BSC6900 HRES3 Threshold THEXT(O reports 3 ptional) the interferen ce on each of the idle channels. This helps the BSC6900 to assign channels. According to the strength of interferen

GBFD111001 GBFD111005

TRX Managem ent Enhanced Interval Channel Type Assignme nt Algorithm

48~115

Threshold used for interferen ce measure ment. The BSS measures the uplink quality of the radio channels occupied by MSs, and Interferen SET calculates INTERFT ce Band GCELLO and BSC6900 HRES4 Threshold THEXT(O reports 4 ptional) the interferen ce on each of the idle channels. This helps the BSC6900 to assign channels. According to the strength of interferen

GBFD111001 GBFD111005

TRX Managem ent Enhanced Interval Channel Type Assignme nt Algorithm

48~115

Interferen SET INTERFT ce Band GCELLO BSC6900 HRES5 Threshold THEXT(O 5 ptional)

BSC Interior INTERIO ADD Clock RSYNCT BSC6900 AISSCFG Synchroni MR (Optional) ze Protect Time

Threshold used for interferen ce measure ment. The BSS measures the uplink quality of the radio channels occupied by MSs, and calculates and reports the interferen ce on each of the idle channels. This helps the BSC6900 to assign channels. According to the strength of interferen Value of the timer for synchroni zation between BSCs. If a BSC fails to synchroni ze with the control BSC before the timer expires, the BSC starts to synchroni ze the BTSs under its

GBFD111001 GBFD111005

TRX Managem ent Enhanced Interval Channel Type Assignme nt Algorithm

48~115

GBFD118201

SoftSynchroni Interval zed Type Network

0~60

Period during which interferen ce levels are averaged. The interferen ce levels on idle channels are averaged before the Interferen SET BTS INTERPE ce GCELLO sends a GBFDBSC6900 RIOD Calculatio THEXT(O radio 111005 n Period ptional) resource indication message to the BSC6900. The averaging result is used for classifyin g the interferen ce levels on idle channels into five This parameter specifies whether Inter-RAT SET INTERRA the Cell GCELLH GBFDTCELLRE BSC6900 reselectio Reselecti OBASIC( 114323 SELEN n from 2G on Enable Optional) cells to 3G cells is allowed. Threshold for setting Inter-RAT SET the flag of InterRatC CS GCELLH accepting sServiceL GBFDService BSC6900 OINTERR inter-RAT oadHoThr 114322 HO Load ATLDB(O CS d Threshold ptional) service handover of a 2G

Enhanced Channel Interval Assignme Type nt Algorithm

1~31

2G/3G Cell Reselecti Enumerati NO(No), on Based on Type YES(Yes) on MS State

GSM/WC DMA Interval Load Type Based Handover

1~100

Inter-RAT SET INTERRA In BSC GCELLH TINBSCH BSC6900 Handover OBASIC( OEN Enable Optional)

Allow SET InterRatIu Incoming GCELLH rgInBscH BSC BSC6900 OBASIC( oEn Handover Optional) at Iur-g

This parameter specifies whether the handover from 3G cells to 2G cells is allowed. Whether to reserve resources for the incoming BSC handover on the Iurg interface

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Enumerati NO(No), GSM/TD- on Type YES(Yes) SCDMA Interopera bility

MRFD211404

MBSC Handover based on Enumerati NO(No), Load on Type YES(Yes) Enhance ment

Width of load band SET [EcNo] InterRATL Inter-RAT GCELLH during the oadHoEc Load HO GBFDBSC6900 OINTERR inter-RAT NoBand Bandwidt 114322 ATLDB(O hierarchic Width h [EcNo] ptional) al loadbased handover

GSM/WC DMA Interval Load Type Based Handover

1~49

Initial EcNo Inter-RAT SET value of InterRATL Load HO GCELLH the inter- GBFDoadHoEc EcNo at BSC6900 OINTERR RAT load- 114322 NoStart Start ATLDB(O based Point ptional) handover band

GSM/WC DMA Interval Load Type Based Handover

0~49

Step of changing the EcNo Inter-RAT SET value InterRATL Hierarchy GCELLH during the GBFDoadHoEc Load HO BSC6900 OINTERR inter-RAT 114322 NoStep Step ATLDB(O hierarchic [EcNo] ptional) al loadbased handover

GSM/WC DMA Interval Load Type Based Handover

1~49

Width of load band SET [RSCP] InterRATL Inter-RAT GCELLH during the oadHoRS Load HO GBFDBSC6900 OINTERR inter-RAT CPBand Bandwidt 114322 ATLDB(O hierarchic Width h [RSCP] ptional) al loadbased handover

GSM/WC DMA Interval Load Type Based Handover

1~91

Initial RSCP Inter-RAT SET value of InterRATL Load HO GCELLH the inter- GBFDoadHoRS RSCP at BSC6900 OINTERR RAT load- 114322 CPStart Start ATLDB(O based Point ptional) handover band

GSM/WC DMA Interval Load Type Based Handover

0~91

Inter-RAT SET InterRATL Hierarchy GCELLH oadHoRS Load HO BSC6900 OINTERR CPStep Step ATLDB(O [RSCP] ptional)

Inter-RAT SET INTERRA Out BSC GCELLH TOUTBS BSC6900 Handover OBASIC( CHOEN Enable Optional)

Step of changing the RSCP value during the inter-RAT hierarchic al loadbased handover This parameter specifies whether the handover from 2G cells to 3G cells is allowed.

GBFD114322

GSM/WC DMA Interval Load Type Based Handover

1~91

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Enumerati NO(No), GSM/TD- on Type YES(Yes) SCDMA Interopera bility

When this parameter is set to Servicebased, the interRAT handover is triggered on the basis of the service distributio Allow SET InterRatS n. In this Inter-RAT GCELLH erviceLoa case, the GBFDLoad HO BSC6900 OINTERR dHoSwitc target cell 114322 in Access ATLDB(O h is State ptional) selected according to the traffic load. When this parameter is set to Loadbased, the interRAT handover is triggered Time span before the command is EXP executed. BSC6900 LOG(Opti The logs onal) generated within the time span are to be exported.

Servicebased(Se rvicebased), Loadbased(Lo adbased), GSM/WC DynamicDMA based(Dy Enumerati Load namic on Type Based Service/L Handover oadbased), CnServic ebased(CN Servicebased), OFF(OFF )

INTERVA Relative L Time

GBFD111203 MRFD210305

O&M of BSC Interval Security Type Managem ent

1~240

STR ETHOAM INTERVA Send PKT BSC6900 LOOPTS L Interval[s] T(Optiona l)

Interval for sending packets to None test Ethernet OAM loop

None

Interval Type

1~10

SET Interferen GCELLE INTFREQ ce BSC6900 XTMSRP UENCY Frequenc ARA(Opti y onal)

Incoming SET INTOINN OL GCELLH REXLEVT Subcell BSC6900 OEDBPA HRED HO Level RA(Optio TH nal)

Frequenc y index of the interferen ce measure ment in type 3 of an extension measure ment Lower threshold of the overlay level during underlayto-overlay handover s. When the receive level of an MS is higher than this threshold, the MS can be switched to the overlay

GBFD110801 GBFD110802

Processin g of Measure ment Report Interval PreType processin g of Measure ment Report

0~31

GBFD114402

Enhanced DualInterval Band Type Network

0~63

INTRABS CCODEC T25 HOCMDT IMER

The timer is used to set the time when the BSC6900 waits for an Internal Handover Comman d message after a SET Internal GCELLT GBFDBSC6900 Handover MR(Optio 110601 Required nal) message is reported in an internal BSC handover when A interface is IP. If the timer expires, the internal

HUAWEI Interval I Type Handover

500~6000 0

INTRABS CHOTIM T3103A ER

Timer started after the BSC6900 delivers a handover command in an intraBSC intercell handover. If the BSC6900 SET receives a GBFDGCELLT handover 110601 BSC6900 MR(Optio complete GBFDnal) message 510501 before this timer expires, the timer stops. If this timer expires, the BSC6900 considers the handover as failed.

HUAWEI I Handover Interval HUAWEI Type II Handover

500~6000 0

Whether to allow AMR handover s. This SET INTRACE Intracell Fparameter GCELLH GBFDLLFHHO H HO BSC6900 has no OBASIC( 115504 EN Allowed impact on Optional) dynamic non-AMR F-H handover s.

AMR FR/HR Enumerati NO(No), Dynamic on Type YES(Yes) Adjustme nt

Intracell INTRACE HO LLHOEN Allowed

This parameter specifies whether the intracell handover SET is GCELLH BSC6900 enabled. OBASIC( Note: A Optional) forced intra-cell handover is not subject to this parameter

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

INTRACE LLHOTIM T3103C ER

Timer started after the BSC6900 delivers a handover command in an intraBSC intracell handover. If the BSC6900 SET receives a GBFDGCELLT handover 110601 BSC6900 MR(Optio complete GBFDnal) message 510501 before this timer expires, the timer stops. If this timer expires, the BSC6900 considers the handover as failed.

HUAWEI I Handover Interval HUAWEI Type II Handover

500~6000 0

Whether it is an ADD RNC INTRAMB GNRNC( MRFDCo-MBSC BSC6900 under the SC Mandator 211402 same y) MBIC in GU mode

MBSC Enumerati NO(No), Load on Type YES(Yes) Balancing

Minimum Ec/No value of a SET Inter-RAT 3G cell IntRATLo GCELLH Load HO during the GBFDadHOEcN BSC6900 OINTERR EcNo load114322 oThr ATLDB(O Threshold based ptional) GSM-toUMTS handover

GSM/WC DMA Interval Load Type Based Handover

0~49

When the load of a cell is greater than or equal to Load HO Threshold , all the calls in the serving cell send handover requests Inter-RAT SET simultane IntRATLo Hierarchic GCELLH GBFDously. adHoPeri al Load BSC6900 OINTERR Thus, the 114322 od HO ATLDB(O load on Period ptional) the CPU increases rapidly. In some cases, the cell is congeste d and call drops might occur. Therefore , the BSC adopts the Minimum RSCP value of a SET Inter-RAT 3G cell IntRATLo GCELLH Load HO during the GBFDadHORS BSC6900 OINTERR RSCP 114322 loadCPThr ATLDB(O Threshold based ptional) GSM-toUMTS handover In BSC Start Timeslot No. Incoming ADD BSC6900 SEMILIN GBFDBSC6900 start K(Mandat 114701 timeslot ory) number

GSM/WC DMA Interval Load Type Based Handover

1~255

GSM/WC DMA Interval Load Type Based Handover

0~91

INTSN

SemiPermane Interval nt Type Connectio n

0~255

INTSNO

ADD DXX In DXXTSE Time Slot BSC6900 XGRELA No. TION(Ma ndatory)

Number of a DXX GBFDIn111203 timeslot

O&M of BSC

Interval Type

0~31

INTV

Time Interval

ADD BSC6900 SUBTSK( Optional)

INTV

OMU SET Automatic ASWPAR BSC6900 Switchove A(Mandat r Interval ory)

Interval for executing the scheduled subtask. If the time mode is set to "DAILY_C ", "WEEKLY _C", or "MONTHL Y_C", you should set this parameter Automatic switchove r interval. This parameter needs to be set only when "OMU automatic switchove r switch" is set to "ON". The minimum automatic switchove r interval is 30 days and the maximum automatic switchove r interval is 1024 days.

GBFD111203

O&M of BSC

Interval Type

1~1440

GBFD111203

O&M of BSC

Interval Type

30~1024

Whether a measure ment report can contain the SET informatio Invalid GCELLC INVALBSI n about a GBFDBSIC BSC6900 CUTRAN CEN cell with 117501 Reporting SYS(Opti an invalid onal) BSIC. The cell with an invalid BSIC is an unconfigu ADD XPUVLA IP BSC6900 N(Mandat address ory) EXP LOG(Opti onal) ADD SNTPSR VINFO(M andatory) BSC6900 DLD LICENSE (Mandator y) ULD LICENSE (Mandator ADD NSVLLO BSC6900 CAL(Man datory)

Enhanced Measure Enumerati NO(No), ment on Type YES(Yes) Report(E MR)

IP

IP Address

MRFD210301

Configura IP tion Address Managem Type ent

None

IP

IP Address

IP address of the server

GBFD111203 MRFD210403

O&M of BSC IP License Address Managem Type ent

None

IP

Local IP Address

IP address of the local NSVL

GBFD118603

Gb over IP

IP Address Type

None

IP

Remote IP Address

IP ADD address NSVLRE BSC6900 of the MOTE(Ma remote ndatory) NSVL

GBFD118603

Gb over IP

IP Address Type

None

IP

Physical IP

SET BTSETH PORT(Op tional) BSC6900 IMP BTSDEVI P(Optiona l)

IP

DLD RETANT CFG(Man datory) ULD BTSDEV FILE(Man datory) DLD FTPServe BTSPAT BSC6900 r IP CH(Mand atory) ULD BTSLOG( Mandator y) DLD BTSSW( Mandator y)

IP address of a BTS port. It cannot be the same as any IP address configure d in the BSC6900. IP address of the FTP server. When the FTPServe r.exe file is download ed through the FTP Tool button on the LMT, the address of the FTP

GBFD118601

IP Abis over Address IP Type

None

GBFD111202

O&M of BTS

IP Address Type

None

IPADDR

Local IP address

The local IP address must be the configure ADD d IP IPPATH( address GBFDBSC6900 Mandator (including 118605 y) the IP address and port address of the interface board).

IP QOS

IP Address Type

None

IPADDR

IP address

IP ADD address BSC6900 DEVIP(M of the andatory) board

GBFD118611 GBFD118622 MRFD211502

IPADDR

Local IP address

Local IP ADD address BSC6900 ETHIP(M of the andatory) Ethernet port

MRFD211502

IPADDR

Source IP address ADD of the Packet ICMPGU packet for source IP BSC6900 None ARD(Man preventin address datory) g the ICMP attack

Abis IP over E1/T1 A IP over IP E1/T1 IP-Based Address 2G/3G Co- Type Transmis sion on MBSC Side IP-Based 2G/3G CoIP Transmis Address sion on Type MBSC Side

None

None

None

IP Address Type

None

IPADDR

ADD Next Hop VLANID( IP BSC6900 Mandator address. y) Local IP address

IPADDR

IP address None of the next hop Local IP ADD address ETHTRKI BSC6900 of the None P(Mandat aggregati ory) on group ADD SGSNRO BSC6900 UTEINFO (Mandator y) IP address of the router

None

IP Address Type IP Address Type

None

None

None

IPADDR

IP Address

GBFD118603

Gb over IP

IP Address Type

None

First IP ADD IP address IPADDR1 BSC6900 SGSN(Ma Address1 of the ndatory) SGSN

GBFD118603

Gb over IP

IP Address Type

None

It must be the valid address of the A, Master SET B, or C Clock BTSIPCL type and GBFDIPADDR1 BSC6900 Server IP KPARA(M cannot be 118606 Address andatory) the broadcast address or network Second ADD IP IP IPADDR2 BSC6900 SGSN(Op address Address2 tional) of the SGSN

Clock over IP

IP Address Type

None

GBFD118603

Gb over IP

IP Address Type

None

It must be the valid address of the A, Slave SET B, or C Clock BTSIPCL type and GBFDIPADDR2 BSC6900 Server IP KPARA(M cannot be 118606 Address andatory) the broadcast address or network

Clock over IP

IP Address Type

None

Third IP ADD IP address IPADDR3 BSC6900 SGSN(Op Address3 of the tional) SGSN

GBFD118603

Gb over IP

IP Address Type

None

Fourth IP ADD IP address GBFDIPADDR4 BSC6900 SGSN(Op Address4 of the 118603 tional) SGSN SET BTSETH PORT(Op tional) ADD BTSPPPL NK(Optio nal) IP Frame ADD Error BSC6900 BTSMPG Alarm RP(Optio Threshold nal) IMP BTSPPPL NK(Optio nal) IMP BTSMPG RP(Optio SET BTSETH PORT(Op tional) ADD BTSPPPL NK(Optio IP Frame nal) Error ADD Alarm BSC6900 BTSMPG Clearance RP(Optio Threshold nal) IMP BTSPPPL NK(Optio nal) IMP BTSMPG RP(Optio

Gb over IP

IP Address Type

None

IPEAAT

When the number of error frames on the IP layer reaches the value GBFDof this 118630 parameter , the frame error alarm is generated .

Ethernet OAM

Interval Type

0~100

IPEADT

When the number of error frames on the IP layer decrease s to the GBFDvalue of 118630 this parameter , the frame error alarm is cleared.

Ethernet OAM

Interval Type

0~100

IPHC

Whether to ADD Head compress BSC6900 PPPLNK( compress the Optional) packet headers

GBFD118611 GBFD118622

No_HC(N o_HC), Abis IP UDP/IP_ over HC(UDP/I Enumerati E1/T1 P_HC), on Type A IP over RTP/UDP E1/T1 /IP_HC(R TP/UDP/I P_HC)

IPHC

Whether to ADD compress Head MRFDBSC6900 MPGRP( the IP compress 210103 Optional) header of a MP group

No_HC(N o_HC), UDP/IP_ Link HC(UDP/I Enumerati aggregati P_HC), on Type on RTP/UDP /IP_HC(R TP/UDP/I P_HC)

IP IPINDEX address index

ADD BSC6900 ETHIP(M andatory) ADD ETHTRKI BSC6900 P(Mandat ory)

IP IPINDEX address index

IP address index of the Ethernet port IP address index of the aggregati on group

GBFD118611 GBFD118622 GBFD118611 GBFD118622

Abis IP over E1/T1 A IP over E1/T1 Abis IP over E1/T1 A IP over E1/T1

Interval Type

0~5

Interval Type

0~5

IPMUXIN IP MUX DEX Index

ADD IP packet BSC6900 IPMUX(O multiplex None ptional) index

None

Interval Type

0~12999

IPPHYTR IP Phy ANSTYP Trans E Type

Type of the ADD physical GBFDBSC6900 BTS(Opti IP 118601 onal) transmissi on medium

IP_OVER Abis over Enumerati _FE/GE, IP on Type IP_OVER _E1

IP IPPHYTR Physical ANSTYP Tran. E Type

ADD BTSAUT OPLAN(O ptional) BSC6900 IMP BTSIPPA RA(Mand atory)

Type of IP physical transmissi GBFDon cable 118601 medium, E1 or FE/GE.

IP_OVER _FE/GE(I P_OVER Abis over Enumerati _FE/GE), IP on Type IP_OVER _E1(IP_O VER_E1)

DHEU ISADDED Heater TMPCON Control TROL Allowed

Whether to enable the heater. In multimode scenario, the value of this SET parameter BTSDHE GBFDBSC6900 in one UBP(Opti 111202 mode onal) must be the same as the value of the correspon ding parameter in another Whether ADD the BSC AISSCFG GBFDBSC6900 is a (Mandator 118201 reference y) BSC

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

ISBASICB Base SC BSC

SoftNO(NO), Synchroni Enumerati YES(YES zed on Type ) Network

Whether the cell is a chain neighbori ng cell. The parameter is used in the quick handover algorithm. Quick handover aims to increase ADD the Chain ISCHAIN G2GNCE handover GBFDNeighbor BSC6900 NCELL LL(Option success 510103 Cell al) rate of an MS moving at a high speed and to ensure the call continuity and low call drop rate. Quick handover applies to the

Chain Enumerati NO(No), Cell on Type YES(Yes) Handover

Whether to support Clock SET clock ISCLKRE Server BTSIPCL server GBFDBSC6900 DUCY Redunda KPARA(M redundan 118606 ncy andatory) cy configurat ion

Clock over IP

UNSUPP ORT(Not Support Enumerati Reducy), on Type SUPPOR T(Support Reducy)

Whether to support Clock SET clock ISCLKRE Server BTSIPCL server GBFDDUCYBA BSC6900 Redunda KPARA(M redundan 118606 K ncy andatory) cy configurat ion

Clock over IP

UNSUPP ORT(Not Support Enumerati Reducy), on Type SUPPOR T(Support Reducy)

ISCONFI Config GEDRIN Ring G

Whether to enable the BTS to support ring ADD networkin GBFDBSC6900 BTS(Opti g. IP BTS 117801 onal) does not support this parameter .

Ring Enumerati NO(No), Topology on Type YES(Yes)

When this parameter is set to Yes, the boardlevel verificatio n threshold is used, including the following parameter s: Configure ADD Forward ISCONFI Check BTSRXU Bandwidt GBFDBSC6900 GTHD Threshold BRD(Opti h, 111202 s or Not onal) Receive Bandwidt h, Power Class, and TRX Number. When this parameter is set to No, the BSC-level verificatio n threshold specified byservice A the EDGE ADD Support in ISEDGES GEXT2G External BSC6900 UPPORT CELL(Opt Neighbou ional) r Cell support attribute of a cell, that is, whether an external GSM cell supports Whether to indicate the first class transport resource group A service support attribute of a cell, that is, whether an external GSM cell supports

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD114201

EGPRS

NO(Not Enumerati support), on Type YES(Sup port)

Is First ADD Class ISFIRSTC RSCGRP Transport BSC6900 LASS (Mandator Resource y) Group

GBFD118605

IP QOS

NO(NO), Enumerati YES(YES on Type )

GPRS ADD Support in ISGPRSS GEXT2G External BSC6900 UPPORT CELL(Opt Neighbou ional) r Cell

GBFD114101

GPRS

NO(Not Enumerati support), on Type YES(Sup port)

Is Main ISMAINB BCCH CCH TRX

Whether to enable ADD the TRX MRFDBSC6900 GTRX(Op to carry 210301 tional) the main BCCH in the cell Whether a BSC in the TC GBFDpool is the 113726 primary BSC Whether this location group is the main location group. If the value is Yes, this location group is the main location group. If the value is No, this location group is the slave location group. A service support attribute of a cell, that is, whether an external GSM cell supports

Configura tion Enumerati NO(No), Managem on Type YES(Yes) ent

IsMainBS Is Main C BSC

SET BSCBASI BSC6900 C(Mandat ory)

TC Pool

Enumerati NO(No), on Type YES(Yes)

Is Main ISMAINL Local OCGRP Group

ADD BTSLOC BSC6900 GRP(Man datory)

GBFD510104

NO(NO), Multi-site Enumerati YES(YES Cell on Type )

NC2 ADD Support in ISNC2SU GEXT2G External BSC6900 PPORT CELL(Opt Neighbou ional) r Cell

GBFD116201

NetworkNO(Not Controlled Enumerati support), Cell on Type YES(Sup Reselecti port) on (NC2)

Configura tion mode of the IP subnetwo rk. Static configurat ion: fixed local NSVL and remote NSVL parameter s through manual configurat Subnetwo ion; ADD ISNCMO rk Dynamic GBFDBSC6900 NSE(Opti DE Configure configurat 118603 onal) Mode ion: the NSVL parameter obtained through negotiatio n between the BSC and the SGSN after the local NSVL and SGSN service Whether IS ADD ISQOSPA it is QOSPAT BSC6900 IPMUX(M None TH QOSPAT H andatory) H Whether the Um interface ADD software ISSPTBS Support AISSCFG GBFDBSC6900 synchroni CAISS BSC AISS (Mandator 118201 zation y) between BSCs is supported Whether Demu SET multiple ISSPTDE Configure BTSENV DEMUs GBFDBSC6900 MUS Informatio ALM(Man are 111202 n datory) configure d

Gb over IP

STATIC(S Enumerati tatic), on Type DYNAMIC (Dynamic)

None

NO(NO), Enumerati YES(YES on Type )

SoftNO(NO), Synchroni Enumerati YES(YES zed on Type ) Network

O&M of BTS

YES(Conf igure), Enumerati NO(Not on Type Configure )

SET ISSUPER Is Supper BTSOTH ISSUPER GBFDBSC6900 BTS BTS PARA(Op BTS 117803 tional) Whether to enable the BTS to support local switching If the BTS supports local switching, when the calling and called MSs are both within the SET GBFDBTS or BSC6900 BTSLSW( 117702 BTS Optional) group, the voice signals are looped back to the MSs within the BTS or BTS group instead of being sent over the Abis interface

Abis NO(NO), Transmis Enumerati YES(YES sion on Type ) Backup

Support ISSUPPO BTS RTBTSLS Local WITCH Switch

BTS Local Switch

Enumerati NO(No), on Type YES(Yes)

Whether to support the TC pool function. The TC Pool feature is implemen ted by connectin g the maim processin g SET subracks IsSupport Is Support BSCBASI (MPSs) GBFDBSC6900 TcPool Tc Pool C(Optiona and 113726 l) extended processin g subracks (EPSs) in multiple BSC6900 s to the transcode r subracks (TCSs) of one BSC6900. In this manner, Whether it is a TC board.If the board is for the TC subrack, ADD set the MRFDISTCBRD TC board BSC6900 BRD(Man parameter 210301 datory) to YES. If the board is not for the TC subrack, set the parameter ADD SUBRAC BSC6900 K(Optiona l) Whether the subrack is MRFDa remote 210301 main TC subrack

TC Pool

Enumerati NO(No), on Type YES(Yes)

Configura tion Enumerati YES(YES Managem on Type ), NO(NO) ent

Remote ISTCCEN TC TRAL Central

Configura NO(NO), tion Enumerati YES(YES Managem on Type ) ent

Whether to control the temperatu re difference between the air inlet and air outlet and that between the air outlet and ambient DHEU SET by the ISTMPCT Temperat BTSDHE temperatu GBFDBSC6900 RL ure UBP(Opti re control 111202 Control onal) system. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding Whether to configure the transmissi on Tran. SET cabinet. ISTRANC Cabinet BTSPSU BSC6900 The BTS ABCON Configure FP(Option uses this d al) parameter to calculate the number of TRXs to

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD111202 GBFD117804

O&M of NOT_CO BTS NFIG(NO Intelligent T Shutdown Enumerati CONFIG of TRX on Type URED), Due to CONFIG( PSU CONFIG Failure URED)

ITEM

SET GCELLID LEFDDB A1(Mand atory) SET GCELLID LETDDB A1(Mand atory) SET GCELL2 NCCELL BSC6900 GBA1(Ma No. ndatory) SET GCELLH O2GBA2( Mandator y) SET GCELLH OFDDBA 2(Mandat ory) SET

Number of a row to be changed in a BA list

MRFD210301

Configura tion Interval Managem Type ent

1~64

ITEMIND Item EX Index

Reserved parameter for cells. There are 30 SET parameter GCELLR s of this MRFDBSC6900 EV(Mand type, 210301 atory) which can be used as new parameter s in later versions.

Configura tion Interval Managem Type ent

1~30

SET GCELLID LEFDDB A1(Mand atory) SET GCELLID LETDDB A1(Mand atory) SET GCELL2 Used for ITEMVALI MRFDItem Valid BSC6900 GBA1(Ma parameter D 210301 ndatory) control SET GCELLH O2GBA2( Mandator y) SET GCELLH OFDDBA 2(Mandat ory) SET SET GCELLR BSC6900 EV(Mand atory) ADD IPPATH( Mandator y) ADD BSC6900 ADJMAP( Mandator y) ADD TRMMAP (Mandator Value of a reserved MRFDparameter 210301 for cells

TRUE(Su Configura pport), tion Enumerati FALSE(N Managem on Type ot ent Support)

ITEMVAL Value UE

Configura tion Interval Managem Type ent

0~65535

ITFT

Interface Type

Type of the adjacent node

GBFD118605

IP QOS

ABIS(Abis Interface), A(A Interface), Enumerati ATER(AT on Type ER Interface), IUR_G(IU R_G Interface)

ITFType

Interface Type

ADD BTSIPRT( Mandator y) BSC6900 IMP BTSIPRT( Mandator y)

Type of the interface. This is determine d by the type of the protocol currently used by the BTS. Point-toPoint Protocol (PPP) is a data link GBFDprotocol. 118605 Multilink PPP (MP) is a bandwidthondemand protocol that binds multiple links together according to PPP (also called link aggregati

IP QOS

Enumerati PPP(PPP on Type ), MP(MP)

IUO

Concentri c cell attributes of TRX. If the cell where a TRX is located is configure d as a concentric cell, set this parameter to SET OVERLAI Concentri GTRXIUO D or GBFDBSC6900 c Attribute (Mandator UNDERL 113201 y) AID as required. If the cell where a TRX is located is not configure d as a concentric cell, the default value of this parameter is NONE.

OVERLAI D(Overlai d Subcell), Concentri Enumerati UNDERL c Cell on Type AID(Unde rlaid Subcell), NONE(No ne)

Dynamic Conversio Channel n policy of Conversio SET the IUOCHNT n GCELLP dynamic BSC6900 RAN Paramete SCHM(O channel r of ptional) of the Concentri concentric c Cell cell

GBFD113101 GBFD113201 GBFD119303 GBFD119501

CONVER T0(Only PDCH convert at Dynamic UL), Adjustme CONVER nt T1(Only Concentri convert at c Cell OL), Load Enumerati CONVER Sharing on Type T2(UL Adaptive first and Adjustme convert nt of allowed), Uplink CONVER and T3(OL Downlink first and Channels convert allowed)

UO HO IUOHOD Valid URATIME Time

The triggering of concentric circle handover s must meet the P/N criteria, that is, when P out of N measure ment SET reports GCELLH GBFDBSC6900 meet the OIUO(Opt 113201 condition ional) for concentric circle handover s, a concentric circle handover is triggered. This parameter correspon ds to the P in the

Concentri Interval c Cell Type

1~32

UO HO IUOHOST Watch ATIME Time

The triggering of concentric circle handover s must meet the P/N criteria, that is, when P out of N measure ment SET reports GCELLH GBFDBSC6900 meet the OIUO(Opt 113201 condition ional) for concentric circle handover s, a concentric circle handover is triggered. This parameter correspon ds to the N in the

Concentri Interval c Cell Type

1~32

IUOTP

J0ALMS WITCH

Whether a cell is a normal cell, concentric cell, or enhanced dual band network cell. In a concentric cell, the coverage areas of different ADD Cell IUO TRXs BSC6900 GCELL(O Type form ptional) concentric circles of different radiuses. Owing to different coverage areas of the overlaid and underlaid parts, the two parts can be logically Switch for J0 trace the J0 SET mismatch tracing BSC6900 OPT(Opti alarm mark onal) switch mismatchi ng alarm

GBFD113201 GBFD114402

Normal_c ell(Normal Cell), Concentri Concentri c Cell c_cell(Co Enhanced Enumerati ncentric Dualon Type Cell), Band EDB_cell( Network Enhanced Double Frequenc y Cell)

GBFD118630

Ethernet OAM

Enumerati OFF(OFF on Type ), ON(ON)

J0BYTE_ J0 Byte FORMAT Format

Byte SET display BSC6900 OPT(Man format of datory) J0

GBFD118604 GBFD118610

Hexadeci Abis MUX mal(Hex UDP decimal), MUX for Enumerati Character A on Type _String(C Transmis haracter sion String)

Expected receiving value of J0. J0 byte, also called the trace byte of the regenerat or section J0 on the SET J0RXVAL expected optical BSC6900 OPT(Opti None UE incept port onal) value (RTIM), is one of the optical port interconn ection parameter s. The BSC receives the peer Sending value of J0. J0 byte, also called the trace byte of the regenerat or section on the optical port (RTIM), is one of the optical port J0 SET J0TXVAL interconn transmit BSC6900 OPT(Opti None UE ection value onal) parameter s that is continuou sly transmitte d to the peer end. This parameter enables the peer end to check whether it is connecte

None

String Type

None

None

String Type

None

J0TYPE

J0 type

SET BSC6900 OPT(Opti J0 type onal)

None

None

NULL, Enumerati 1byte, on Type 16byte, 64byte

J1ALMS WITCH

J1 trace SET mismatch BSC6900 OPT(Opti alarm onal) switch

Switch for the J1 tracing None mark mismatchi ng alarm

None

Enumerati OFF(OFF on Type ), ON(ON)

J1BYTE_ J1 Byte FORMAT Format

Byte SET display BSC6900 OPT(Man None format of datory) J1

None

Hexadeci mal(Hex decimal), Enumerati Character on Type _String(C haracter String)

Expected receiving value of J1. J1 byte, also called the trace byte of the high-order path on J1 SET the optical J1RXVAL expected BSC6900 OPT(Opti port, is None UE incept onal) one of the value optical port interconn ection parameter s. The local end continuou sly receives

None

String Type

None

J1 J1TXVAL transmit UE value

Sending value of J1. J1 byte, also called the trace byte of the high-order path on the optical port, is one of the optical port interconn ection SET parameter BSC6900 OPT(Opti None s onal) transmitte d to the peer end continuou sly. This parameter enables the peer end to check whether it is connecte d to the local end continuou

None

String Type

None

J1TYPE

J1 type

SET BSC6900 OPT(Opti J1 type onal)

None

None

NULL, Enumerati 1byte, on Type 16byte, 64byte

J2ALMS WITCH

Switch for J2 SET the J2 mismatch COPTLN tracing BSC6900 None alarm K(Optiona mark switch l) mismatchi ng alarm

None

Enumerati OFF(OFF on Type ), ON(ON)

J2BYTE_ J2 Byte FORMAT Format

SET COPTLN BSC6900 K(Optiona l)

Byte display None format of J2

None

Hexadeci mal(Hex decimal), Enumerati Character on Type _String(C haracter String)

SET Byte COPTLN J2MODE J2 length BSC6900 length of K(Optiona J2 l)

None

None

NULL, Enumerati 1BYTE, on Type 16BYTE, 64BYTE

J2 SET J2RXVAL expected COPTLN BSC6900 UE incept K(Optiona value l)

Expected receiving None value of J2

None

String Type

None

J2 J2TXVAL transmit UE value

SET Sending COPTLN BSC6900 value of K(Optiona J2 l)

None

None

String Type

None

JAUTOA DD

A zero or a space used to fill in the J byte of the optical port based on the J byte of the peer equipmen SET t. If the J OPT(Opti bytes are Automatic onal) inconsiste Append J BSC6900 SET nt, an None Byte COPTLN alarm K(Optiona related to l) J byte mismatch will be reported and the negotiatio n of the optical port may fail, thus leading to deteriorati on of the

None

ZERO(zer Enumerati o), on Type SPACE(s pace)

JBF

LAPD SET Jitter BTSJBF( BSC6900 Buffer Mandator Algorithm y)

PS Jitter JITBUFD Buffer ELAY Delay

SET BTSOTH BSC6900 PARA(Op tional)

Whether to enable the LAPD Jitter Buffer algorithm. This algorithm adds a buffering adaptatio n layer under the LAPD layer at the receiving end. The function at this layer is to delay the I frame (first received, last sent) currently received. If an I frame is received within the delayed duration, Default receive delay of the PS Jitter Buffer on the BTS. A greater value of this parameter indicates a longer end-toend delay for the PS service.

GBFD118401

Abis DISABLE( Transmis Enumerati Disable), sion on Type ENABLE( Optimizati Enable) on

GBFD111612

MultiCarrier Intelligent Interval Voltage Type Regulatio n

1~255

Jitter JITBUFS Buffer WITCH switch

Whether the LAPD SET Jitter OTHSOF GBFDBSC6900 Buffer is TPARA(O 118601 enabled ptional) on the BSC side

DENY(De Abis over Enumerati ny), IP on Type ALLOW(A llow)

Determin es whether the last SET three bits K2MODE K2 Mode BSC6900 MSP(Opti of K2 None onal) indicates the single end and the dual end

None

NOTINDICAT EEND(NOTINDICAT Enumerati E-END), on Type INDICAT EEND(INDI CATEEND)

KBIAS

K Bias

K offset used in K sequencin g. To reduce ping-pong handover s, the system performs K sorting based on the SET downlink GCELLH receive BSC6900 OAD(Opti level of onal) the candidate cells. But before doing that, the system subtracts "K Bias" from the actual downlink receive level of

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

ADD PPPLNK( KeepKEEPALI Optional) alive timer BSC6900 VE ADD length[S] MPLNK(O ptional)

Duration of the PPP/MP None link keepalive timer

None

Interval Type

1~30

LAC

Cell LAC

ADD GCELL(M andatory) ADD GEXT2G CELL(Ma ndatory) ADD GEXT3G CELL(Ma ndatory) SET FHO(Man datory) BSC6900 ADD BTSAUT OPLAN(M andatory) SET BTSAUT OPLANC FG(Optio nal) ADD GCELLQ UICKSET UP(Mand atory)

Location area code (LAC). MSs can freely move in the local location area with no need of location update. Reasonab le local allocation can effectively MRFD210301 lighten the signaling load and improve the call completio n rate. Can be input in hexadeci mal format. The hexadeci mal format is

Configura tion Interval Managem Type ent

1~65533, 65535

LAC1

Cell LAC

Location area code (LAC). The MS can move within the local location area without location update. The SET reasonabl BTSAUT GBFDe BSC6900 OPLANC classificati 510702 FG(Optio on of the nal) location area is very important for reducing the signaling load and improving the putthrough rate. Aggregati on mode. When this parameter is set to static aggregati on, the LACP protocol is activated; otherwise, the LACP protocol is deactivate d. Decimal value when the latitude where a cell is located is indicated in the format of degree

Compact BTS Interval Automatic Type Capacity Planning

1~65533, 65535

ADD LACPMO Aggregati ETHTRK( BSC6900 DE on Mode Mandator y)

GBFD111701

STATIC_ Board LACP, Enumerati Switchove MANUAL on Type r _AGGRE GATION

Latitude LATIDECI Decimal Part

SET GCELLLC BSC6900 S(Mandat ory)

GBFD115402

BSSBased String LCS (Cell Type ID + TA)

None

Latitude LATIDEG Degree REE Part

SET GCELLLC BSC6900 S(Mandat ory)

LATIINT

Latitude Int Part

SET GCELLLC BSC6900 S(Mandat ory)

Decimal value when the longitude where a cell is located is indicated in the format of degree Integer value when the latitude where a cell is located is indicated in the format of degree Value of

GBFD115402

BSSBased Interval LCS (Cell Type ID + TA)

0~90

GBFD115402

BSSBased Interval LCS (Cell Type ID + TA)

0~90

LATIMIN UTE

Latitude Minute Part

the minute part when SET the GCELLLC latitude is GBFDBSC6900 S(Mandat indicated 115402 ory) in the format of degree_m inute_sec ond Decimal value of the second part when SET the GCELLLC GBFDBSC6900 latitude is S(Mandat 115402 indicated ory) in the format of degree_m inute_sec ond Integer value of the second part when SET the GCELLLC GBFDBSC6900 latitude is S(Mandat 115402 indicated ory) in the format of degree_m inute_sec ond

BSSBased Interval LCS (Cell Type ID + TA)

0~59

Latitude LATISEC Second ONDDEC Decimal I Part

BSSBased Interval LCS (Cell Type ID + TA)

0~9

Latitude LATISEC Second ONDINT Int Part

BSSBased Interval LCS (Cell Type ID + TA)

0~59

GPS LATITUD antenna E latitude GPS LATITUD antenna ESEC latitude

LATPRD

Delay measure period [100ms]

Longitude ADD of the BSC6900 GPS(Man GPS datory) receiver antenna Longitude ADD of the BSC6900 GPS(Man GPS datory) receiver antenna Delay statistics period. This parameter indicates the period to collect the statistics informatio n about the link transmissi on delay. ADD Note that IPLOGIC BSC6900 the unit of PORT(Op this tional) parameter is 100 millisecon ds. The actual delay statistics period is the value of this parameter multiplied by 100 millisecon ds.

MRFD210502

BSC/RNC Interval Clock Type

90000000 ~9000000 0 None

MRFD210502

BSC/RNC String Clock Type

MRFD210103

Link Interval aggregati Type on

1~100

Delay adjust LATSUST suspend M period [LATTH]

ADD IPLOGIC BSC6900 PORT(Op tional)

LATTH

Rate ADD down IPLOGIC threshold BSC6900 PORT(Op for delay tional) [ms]

Number of delay adjustme nt suspensio n periods. This parameter specifies the delay statistics periods in which the bandwidth is not adjusted when the None bandwidth adjustme nt function of the logical port is triggered due to the change of the link transmissi on delay. This parameter can be used to Bandwidt h reduction delay threshold. This parameter is used to trigger the function GBFD118605 of bandwidth reduction at the logical port when the link delay exceeds the value

None

Interval Type

0~100

IP QOS

Interval Type

0~10000

Average average ADD delay delay IPLOGIC GBFDLATUDK BSC6900 reduction down filter PORT(Op 118605 filtering mantissa tional) index

IP QOS

Interval Type

0~15

LATUPK

Average average ADD delay delay up IPLOGIC BSC6900 increase filter PORT(Op filtering mantissa tional) index Layer where a cell is located. The network designed by Huawei has four SET layers: GCELLB Umbrella BSC6900 ASICPAR (layer 4), A(Optiona Macro l) (layer 3), Micro (layer 2), and Pico(layer 1). Each layer can be set with 16 priorities.

GBFD118605

IP QOS

Interval Type

0~15

LAYER

Layer of The Cell

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati 1, 2, 3, 4 HUAWEI on Type II Handover

LAYER

Layer of the cell

A network basically consists of four layers, namely, Umbrella, Macro, Micro, and Pico. Cell priorities influence the sorting of ADD neighbori GEXT2G ng cells BSC6900 CELL(Opt during ional) handover s as well as handover algorithm s including PBGT and interlayer handover s. For example, PBGT handover s can only

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati 1, 2, 3, 4 HUAWEI on Type II Handover

LAYHOL OADTH

InterSET Layer HO GCELLH BSC6900 Load OAD(Opti Threshold onal)

Lb ADD Congestio LBConge GEXTSM n BSC6900 stProtect1 LC(Option Protection al) Timer 1

When the load of the serving cell reaches the threshold, the interlayer handover algorithm takes effect. Through GBFDconfigurat 110601 ion of the parameter , the handover to a lowerlayer cell for loadsharing is performe d only when the load of the serving cell Timer of increasing the Lb flow control level when the BSC receives an SMLC congestio n indication. None If the BSC receives another SMLC congestio n indication before the timer expires, the flow control level

HUAWEI Interval I Type Handover

0~100

None

Interval Type

0~300

Timer of decreasin g the Lb flow control level. If no SMLC congestio n indication Lb is ADD Congestio received LBConge GEXTSM n BSC6900 within the None stProtect2 LC(Option Protection valid al) Timer 2 period of the timer, the BSC decrease s the flow control level by one until the flow control level is

None

Interval Type

0~300

LDRFOU LDR H Fourth

Fourth SET action BSC6900 LDR(Opti taken for onal) load control

GBFD118601 GBFD117301

LDRFST

First SET action LDR First BSC6900 LDR(Opti taken for onal) load control

GBFD118601 GBFD117301

CLOSE(C lose), PSDOWN (PS Downspe eding), Abis over AMRC(A Enumerati IP MRC), on Type Flex Abis CSPH(CS Preferenc e TCHH), CSFHHO( CS TCHFTCHH HO) CLOSE(C lose), PSDOWN (PS Downspe eding), Abis over AMRC(A Enumerati IP MRC), on Type Flex Abis CSPH(CS Preferenc e TCHH), CSFHHO( CS TCHFTCHH HO)

LDR LDRSND Second

Second SET action BSC6900 LDR(Opti taken for onal) load control

GBFD118601 GBFD117301

CLOSE(C lose), PSDOWN (PS Downspe eding), Abis over AMRC(A Enumerati IP MRC), on Type Flex Abis CSPH(CS Preferenc e TCHH), CSFHHO( CS TCHFTCHH HO)

LENO

ADD M3LE(Ma Local ndatory) BSC6900 entity No. ADD M3DE(Ma ndatory)

The local entity number uniquely identifies a local entity.

GBFD118602 GBFD118622

A over IP Interval A IP over Type E1/T1

0~186

LEVEL

EXP Level of Log Level BSC6900 LOG(Opti the log onal)

GBFD111203 MRFD210305

CRITICAL O&M of (Critical), BSC Enumerati MAJOR( Security on Type Major), Managem MINOR(M ent inor) INFO(Info rmation Level), WARN(W Enumerati arn on Type Level), ERR(Erro r Level), AST(Asse rt Level) ON(ON), Enumerati OFF(OFF on Type )

LEVEL

COL Log level GBFDLog Level BSC6900 LOG(Opti to be 111203 onal) collected.

O&M of BSC

LEVEL

Alarm Mask Switch

SET Alarm BSC6900 ALMML(M mask andatory) switch Class of ADD the BSC6900 ETHMD( maintena Optional) nce domain Whether to support SET the GCELLB reporting BSC6900 ASICPAR of the A(Optiona main l) diversity level

None

None

Level

MD LEVEL

GBFD118605

IP QOS

Interval Type

0~7

Level LEVELRP Report T Switch

GBFD110801 GBFD110802

Processin g of NO(Not Measure Support), ment Enumerati YES(Sup Report on Type port), PreNONE(Inv processin alid) g of Measure ment

Whether to allow inter-layer and interlevel handover s. The inter-layer and interlevel handover algorithm is SET achieved LEVHOE Level HO GCELLH through BSC6900 N Allowed OBASIC( the Optional) setting of different layers and priorities for cells, which switches traffic to cells of a higher preceden ce (decided

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

Hysteresi s value during the handover s between cells on different layers or of different priorities. This value is used to suppress inter-layer Inter-layer SET ping-pong LEVHOH HO GCELLH handover BSC6900 YST Hysteresi OBASIC( s. s Optional) Inter-layer handover threshold of the serving cell = "Interlayer HO threshold" - "Interlayer HO Hysteresi s"; Inter-layer handover threshold

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

The triggering of interlayer handover s must meet the P/N criteria, that is, when the condition for interlayer ADD Layer HO handover G2GNCE LEVLAST Valid BSC6900 s is met LL(Option Time for a al) consecuti ve P seconds during N seconds, an interlayer handover is triggered. This parameter correspon ds to the

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~32

The triggering of interlayer handover s must meet the P/N criteria, that is, when the condition for interlayer ADD Layer HO handover G2GNCE LEVSTAT Watch BSC6900 s is met LL(Option Time for a al) consecuti ve P seconds during N seconds, an interlayer handover is triggered. This parameter correspon ds to the

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~32

Logical LGCAPP function TYPE type

Logical function type of the board OAM:Ope ration And Maintena nce Process TDM_Swit ching:TD M switching process GCP:All the GCP ADD subsyste MRFDBSC6900 BRD(Opti 210301 ms are onal) configure d as CPUS to act as the control plane processin g subsyste ms for GSM BSC RGCP:Su bsystem 0 of RGCP is configure

OAM, TDM_Swit ching, GCP, RGCP, MCP, GTC, GPCU, Configura IP, FR, tion Enumerati HDLC, Managem on Type TDM, ent GbIP, Abis_TD M, Ater_TDM , Pb_TDM, A_TDM, Abis_IP, SAU

Logical LGCAPP function TYPE type

Logic LGCAPP function TYPE type

Logical function type of the board TDM_Swit ching:TD M switching process GCP:All the GCP subsyste ms are CON configure PATCH(O d as ptional) CPUS to LOD act as the MRFDBSC6900 PATCH(O 210301 control ptional) plane LOD processin BRD(Opti g onal) subsyste ms for GSM BSC RGCP:Su bsystem 0 of RGCP is configure d as the MPU subsyste m to act as the ADD PPPLNK( GBFDMandator Logical 118611 y) BSC6900 function GBFDADD type 118622 MPGRP( Mandator y)

TDM_Swit ching, GCP, RGCP, MCP, GTC, GPCU, Configura IP, FR, tion Enumerati HDLC, Managem on Type TDM, ent GbIP, Abis_TD M, Ater_TDM , Pb_TDM, A_TDM, Abis_IP

Abis IP over Enumerati IP, E1/T1 on Type Abis_IP A IP over E1/T1

Applicatio Applicatio ADD n type of LGCUSA n type of MRFDBSC6900 BRD(Opti the GETYPE POUc_TD 210301 onal) POUc_TD M M board The Logical ADD Index of GBFDBSC6900 PBSL(Opt PB 111203 ional) signaling link

Configura A/Gb, tion Enumerati Abis/Ater/ Managem on Type Pb/Gb ent

LGIDX

PbSL Logical Index

O&M of BSC

Interval Type

5120~537 5

Lower SET LHUMTH Humidity BSC6900 BTSEXD( D Threshold Optional)

SET Alarm LICALMC LICALMT occur BSC6900 THD HD(Mand threshold atory)

Lower humidity threshold for the environm ent alarm box to report an alarm indicating that the ambient humidity is too low. If the ambient humidity of the BTS is lower than this threshold, the environm ent alarm box reports the alarm. In multimode scenario, the value of this parameter The occur threshold of 20258 alarm,you can set it from 90% to 99% The recover threshold of 20258 alarm,you can set it from 90% to 99% Key field used to identify one LAPD link

GBFD111202

O&M of BTS

Interval Type

0~99

MRFD210304

Faulty Interval Managem Type ent

90~99

SET Alarm LICALMR LICALMT recover BSC6900 THD HD(Mand threshold atory)

MRFD210304

Faulty Interval Managem Type ent

70~95

LINKNO

Link No.

LOP LAPDLNK BSC6900 (Mandator y)

GBFD111203

O&M of BSC

Interval Type

0~17407

LISTTYP Query E Type

EXP GCELLTE BSC6900 MPLATE( Optional)

LKTATE

Link rate type

ADD MTP3LN BSC6900 K(Optiona l) SET ALMPOR BSC6900 T(Optiona l)

Type of the parameter s to be displayed when a cell template is queried. The value "DIFFER ENCE" indicates that the parameter s in the None cell template that are different from those in the default template are displayed. The value "ALL" indicates that all the parameter Rate type of the GBFDdesignate 111804 d link Lower limit for MRFDtriggering 210304 an alarm Lower limit of an alarm. It MRFDis valid for 210301 the analog port.

None

Enumerati DIFFERE on Type NCE, ALL

A Interface Protocol Process

64K(64Kb Enumerati it/s), on Type 2M(2Mbit/ s)

LL

Lower Limit

Faulty String Managem Type ent

None

LL

Lower Limit

SET BTSENV BSC6900 ALMPOR T(Optiona l)

Configura tion String Managem Type ent

None

LLCN

Channel No.

The loopback channel number when the SET port BSC6900 E1T1LOP loopback (Optional) mode is set to single channel local loopback

GBFD118611 GBFD118622

LNA1

Upper threshold of the low noise amplifier. When the working voltage of the low SET LNA noise BTSRXU GBFDThreshold BSC6900 amplifier BP(Optio 111202 1 attenuator nal) in the RXU board is smaller than this value, an alarm is reported by the

TS1(Time _slot_1), TS2(Time _slot_2), TS3(Time _slot_3), TS4(Time _slot_4), TS5(Time _slot_5), TS6(Time _slot_6), TS7(Time _slot_7), TS8(Time Abis IP _slot_8), over Enumerati TS9(Time E1/T1 on Type _slot_9), A IP over TS10(Tim E1/T1 e_slot_10 ), TS11(Tim e_slot_11 ), TS12(Tim e_slot_12 ), TS13(Tim e_slot_13 ), TS14(Tim e_slot_14 ), TS15(Tim

O&M of BTS

Interval Type

0~40

Lower threshold of the low noise amplifier. When the working voltage of the low SET LNA noise BTSRXU GBFDLNA2 Threshold BSC6900 amplifier BP(Optio 111202 2 attenuator nal) in the RXU board is greater than this value, an alarm is reported by the Optical port tributary numberin g method. This parameter indicates the sequence of tributaries in an SDH frame. If the sequence Tributary SET LNKNUM s of Numberin BSC6900 OPT(Opti None MODE tributaries g onal) at both optical ports differ from each other, some E1 links will be disconnec ted. The sequence s of optical port tributaries

O&M of BTS

Interval Type

40~80

None

LUCENT_ MODE, Enumerati HUAWEI on Type _MODE, ALCATEL _MODE

LNKRAT E

ADD Semiperm SEMILIN anent BSC6900 K(Optiona Link Rate l)

Rate of the GBFDsemiperm 114701 anent link

8K(8Kbit/ s), 16K(16Kb Semiit/s), Permane Enumerati 32K(32Kb nt on Type it/s), Connectio 64K(64Kb n it/s), 2M(2Mbit/ s)

Initial bearing tag of the M3UA link. This parameter can be set to either active Initial ADD mode or LNKRED bearing BSC6900 M3LNK(O standby FLAG traffic ptional) mode. For active tag details about the relevant bearer tag, see the the parameter "Traffic mode" of the "ADD

GBFD118602 GBFD118622

M3UA_M ASTER_ MOD(M3 UA_MAS A over IP TER_MO Enumerati A IP over D), on Type E1/T1 M3UA_SL AVE_MO D(M3UA_ SLAVE_M OD)

LNKSLS MASK

Link load sharing. In the value, the number of 1s (represent ed by n) determine s the maximum number (2^n) of links for the load sharing. ADD Signalling GBFDFor BSC6900 MTP3LKS link mask example, 111804 (Optional) B0000 indicates that up to one link is used for the load sharing, B0001 and B1000 indicate that up to two links are used for the load

A Interface Protocol Process

B0000(B0 000), B0001(B0 001), B0010(B0 010), B0011(B0 011), B0100(B0 100), B0101(B0 101), B0110(B0 110), B0111(B0 Enumerati 111), on Type B1000(B1 000), B1001(B1 001), B1010(B1 010), B1011(B1 011), B1100(B1 100), B1101(B1 101), B1110(B1 110), B1111(B1 111)

LNKSLS MASK

Signaling link mask correspon ding to the M3UA link set. It is used for the M3UA link load sharing. It is valid only when the working mode of ADD Signalling GBFDthe BSC6900 M3LKS(O link mask signaling 118602 ptional) link set is set to load sharing. In the value, the number of 1s (represent ed by n) determine s the maximum number (2^n) of links for

B0000(B0 000), B0001(B0 001), B0010(B0 010), B0011(B0 011), B0100(B0 100), B0101(B0 101), B0110(B0 110), B0111(B0 Enumerati 111), A over IP on Type B1000(B1 000), B1001(B1 001), B1010(B1 010), B1011(B1 011), B1100(B1 100), B1101(B1 101), B1110(B1 110), B1111(B1 111)

ADD GEXT2G CELL(Opt ional) Load ADD handover LoadAccT GEXT3G Load BSC6900 hres CELL(Opt Accept ional) Threshold SET GCELLH OAD(Opti onal)

If the load of a cell is lower than the value of this parameter , the cell can admit the users handed over from other cells with higher load. Otherwise , the cell rejects such users.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~100

Type of load balancing algorithm of the MSC Pool. Generally, the BSC6900 chooses an MSC according to the obtained MSC Pool ADD network LOADBA Load GCNOPE resource GBFDLANCEAL Balancing BSC6900 RATOR( indication 117401 G Algorithm Optional) (NRI). In Select some cases, however, the BSC6900 cannot do so. Instead, the BSC6900 chooses a target MSC according to a load

RANDOM ALG(Ran dom Enumerati Algorithm) MSC Pool on Type , OTHERA LG(MS ID Algorithm)

Intervals that the BSC broadcast s a cell's traffic load to its neighbor cells. The uplink load and downlink load indicate the traffic SET situation LOADBR NC2 Load BSCPSS of a cell. GBFDOADCAS Broadcast BSC6900 OFTPAR 116201 The TPERIOD Period A(Optiona uplink l) load = number of uplink TBFs carried on all PDCHs in a cell / total number of PDCHs in a cell x ("PDCH Uplink Multiplex Load SET Load LOADCU Current BTSPMU current GBFDRRENTDI Shunt BSC6900 BP(Optio shunt 111202 V Coefficien nal) coefficient t This parameter specifies whether SET Enhanced to use the LOADHO GCELLH GBFDLoad HO BSC6900 load AD OAD(Opti 110601 Allowed handover onal) or the enhanced load handover.

NetworkControlled Interval Cell Type Reselecti on (NC2)

1~10

O&M of BTS

Interval Type

0~1000

HUAWEI NO(NO), Enumerati I YES(YES on Type Handover )

SET Load LoadHoE GCELLH Handover BSC6900 n OBASIC( Support Optional)

ADD Load LoadHoE GEXT2G Handover BSC6900 nExt2G CELL(Opt Support ional)

This parameter specifies whether a traffic loadsharing handover is enabled. The load handover helps to reduce cell congestio n, improve success rate of channel assignme nt, and balance the traffic load among cells, thus improving the network performa nce. The load Indicates that if a 2G neighbori ng cell supports load handover s, the BSC adds the load informatio n of the local cells in the signaling procedure s related to this neighbori

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

ADD Load LoadHoE GEXT3G Handover BSC6900 nExt3G CELL(Opt Support ional)

ADD LOADHO Load HO G2GNCE PBGTMA PBGT BSC6900 LL(Option RGIN Threshold al)

Indicates that if a 3G neighbori ng cell supports load handover s, the BSC adds the load informatio n of the local cells in the signaling procedure s related to this neighbori If the path loss in the serving cell minus that in a handover candidate cell is not smaller than the parameter value, the handover to the candidate cell is allowed. The parameter loosens the requireme nt of the PBGT handover threshold when the load of the serving cell reaches a certain level.

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

GBFD110601

HUAWEI Interval I Type Handover

0~127

After a load handover succeeds, the BSC punishes the former serving cell during "Penalty Time on Load HO" SET Penalty by LOADHO GCELLH Time on BSC6900 subtractin PENTIME OFITPEN Load HO g "Penalty (Optional) Value on Load HO" from the receive level of the former serving cell, thus avoiding ping-pong handover s.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

After a load handover succeeds, the BSC punishes the former serving cell during "Penalty Time on Load HO" SET LOADHO Penalty by GCELLH PENVAL Value on BSC6900 subtractin OFITPEN UE Load HO g "Penalty (Optional) Value on Load HO" from the receive level of the former serving cell, thus avoiding ping-pong handover s.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

When the load of a cell reaches or exceeds "Load HO Threshold ", all the calls that are using this cell as the serving cell SET generate Load HO LOADHO GCELLH handover Step BSC6900 PERIOD OAD(Opti requests Period onal) at the same time, which will suddenly increase the load of the processor . Under some circumsta nces, congestio n occurs in the cell,

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~255

In hierarchic al load handover s, starting from "Edge HO DL RX_LEV Threshold ", a "Load HO Step Level" is added to the upper SET handover Load HO LOADHO GCELLH threshold Step BSC6900 STEP OAD(Opti after Level onal) every "Load HO Step Period". In this way, all the calls in the current serving cell whose receive level is in the range "Edge HO

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~63

This parameter specifies the ratio of the MSs that simultane ously perform a load handover. You can enlarge the ratio to HO Ratio SET accelerat LOADHO of GCELLH e the GBFDUSRRATI Enhanced BSC6900 OAD(Opti handover 110601 O Load HO onal) to a Algorithm neighbori ng cell for load sharing. Too large a ratio, however, causes the neighbori ng cell to be congeste d. When a

HUAWEI Interval I Type Handover

1~16

SET Load HO LOADOF GCELLH Bandwidt BSC6900 FSET OAD(Opti h onal)

Load SET LOADPW Power-off BTSDPM BSC6900 ROFFEN Allowed UBP(Opti State onal)

In the handover algorithm of the first generatio n, load handover s can be performe d only when the receive level of the current serving cell is in the range "Edge HO DL RX_LEV Threshold " to "Edge HO DL RX_LEV Threshold " + "Load HO Bandwidt h". In the handover algorithm of the Whether to enable load power-off. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

Cell Load SET LOADRE Reselecti GCELLN SELALLO BSC6900 on C2PARA( W Allowed Optional)

Load SET LOADRE Reselect GCELLN SELMAX BSC6900 Level C2PARA( RXLEV Threshold Optional)

Whether to allow the cell load reselectio n. If this parameter is set to PERMIT and "NC2 Load Reselecti on Switch" is set to Support, the load of the target cell is involved in the algorithm for NC2 cell Threshold for allowing the MS to reselect a cell during load reelection . When the receive level of the serving cell is lower than this threshold, the load

GBFD116201

NetworkFORBID( Controlled Enumerati Forbid), Cell on Type PERMIT( Reselecti Permit) on (NC2)

GBFD116201

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~63

Load SET LOADRE Reselecti GCELLN SELRXT on BSC6900 C2PARA( HRSH Receive Optional) Threshold

Load SET LOADRE Reselecti GCELLN SELSTAR BSC6900 on Start C2PARA( TTHRSH Threshold Optional)

LOADSH Balance AREALL Traffic OW Allowed

SET GCELLC BSC6900 HMGAD( Optional)

When the uplink load or downlink load of the target cell is lower than this threshold, it can accept the MSs from the serving cell due to load When the uplink load or downlink load of the cell exceeds this threshold, the load reselectio n decision is made. If this parameter is set to YES, the channel assignme nt algorithm II randomly selects the start range for channel traversal; otherwise, the algorithm selects the channel next to the channel assigned last time

GBFD116201 GBFD114301 GBFD114322

NetworkControlled Cell Reselecti on (NC2) GSM/WC DMA Interval Interopera Type bility GSM/WC DMA Load Based Handover

0~100

GBFD116201

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~100

GBFD111005

Enhanced Channel Enumerati NO(No), Assignme on Type YES(Yes) nt Algorithm

This parameter specifies whether the dynamic PDCHs that have Type of SET been LOADST Cell Load GCELLC GBFDBSC6900 converted ATYPE Calculatio HMGAD( 110601 into the n Optional) PDCHs are considere d during the calculatio n of the current TRM SET TRM load LOADTH Load BSCABIS BSC6900 threshold None SW Threshold PRIMAP( switch switch Optional)

NOTSTA DYNPDC H(Not count dynamic PDCH), DYNPDC HASOCC HUAWEI UPY(Cou Enumerati I nt on Type Handover dynamic PDCH(Oc cupy)), DYNPDC HASIDLE (Count dynamic PDCH(Idl e))

None

Enumerati OFF(OFF on Type ), ON(ON)

LocalBSC Local ID BSC ID

Local SET BSC GBSCRE GBFDBSC6900 identity. It DGRP(M 113725 identifies andatory) a BSC. Local IP address of PPP ADD link. The PPPLNK( BSC6900 IP Mandator address y) of the PPP link on the

BSC Node Interval Redunda Type ncy

0~65534

LOCALIP

Local IP address

None

None

IP Address Type

None

Local IP LOCALIP address

ADD MPGRP( BSC6900 Mandator y)

Local IP address GBFDof the MP 111202 group

O&M of BTS

IP Address Type

None

Local IP LOCALIP Address

ADD BTSPPPL NK(Mand atory) BSC6900 IMP BTSPPPL NK(Mand atory) ADD BTSMPG RP(Mand atory) BSC6900 IMP BTSMPG RP(Mand atory)

Local IP address GBFDof BTS 118611 PPP Link.

Abis IP over E1/T1

IP Address Type

None

LOCALIP

Local IP Address

Local IP address of BTS MLPPP Group.

GBFD118611

Abis IP over E1/T1

IP Address Type

None

LOCALN Local SVLI NSVL ID

LOCALP ORTNO

ADD Identifies NSVLLO GBFDBSC6900 a local CAL(Man 118603 NSVL datory) Identifies the local port of the router. The ADD setting of SGSNRO Local Port this GBFDBSC6900 UTEINFO No. parameter 118603 (Mandator must be y) consistent with the setting at the SGSN side.

Gb over IP

Interval Type

0~1023

Gb over IP

Interval Type

0~1

Location LOCGRP Group NO No.

ADD BTSLOC GRP(Man datory) ADD BTSRXU BSC6900 2LOCGR P(Mandat ory) SWP BTSLOC GRP(Man datory) ADD BTSOBJA BSC6900 LMSHLD( Mandator y)

Number of the location group GBFDunder the 510104 BTS. It is unique for each BTS.

Multi-site Interval Cell Type

0~35

Location LOCGRP Group NO No.

Number of a location group

GBFD510104

Multi-site Interval Cell Type

0~35

EXP Filter of ALMLOG( LOCINFO Location Optional) BSC6900 KEY Informatio STA n ALMLOG( Optional)

The value of this parameter can include one or two conditions . "&" is used to concaten ate the conditions , and the records MRFDare obtained 210304 when the two conditions are matched. Condition s are written in the format of "name : value". "name" is the key of location informatio n, "value"

Faulty String Managem Type ent

None

LOCIP1

Identifies the first local IP address that communi cates with the peer end. ADD When it is First local SCTPLN set to 0, it IP BSC6900 K(Mandat is invalid. address ory) This IP address must be first configure d on the correspon ding interface board. Identifies the second local IP address that communi cates with the peer end. ADD When it is SCTPLN BSC6900 set to 0, it K(Optiona is invalid. l) This IP address must be first configure d on the correspon ding interface board. Whether to lock all the nondefault local accounts

GBFD118602 GBFD118622

A over IP IP A IP over Address E1/T1 Type

None

LOCIP2

Second local IP address

GBFD118602 GBFD118622

A over IP IP A IP over Address E1/T1 Type

None

SET Set OPLOCK( LOCKST Locked/U BSC6900 Mandator nlock y)

GBFD111203 MRFD210305

O&M of BSC OFF(Unlo Enumerati Security ck), on Type Managem ON(Lock) ent

LOCPN

Local SCTP port No.

ADD SCTPLN BSC6900 K(Mandat ory)

Local SCTP port number

GBFD118602 GBFD118622

A over IP Interval A IP over Type E1/T1

1024~655 35

Board LODCTR Start L Load Control.

SET Board LODCTR MRFDBSC6900 start load L(Mandat 210301 control ory)

LODMOD Loading E Mode

LOD BTSSW( Optional) Mode of BSC6900 LOD software BTSPAT loading CH(Optio nal)

GBFD111202

CPU usage threshold for log flow control. When the average SET Log CPU LOGCTH FCCPUT GBFDcontrol BSC6900 usage of D HD(Optio 111705 threshold sliding nal) windows reaches or exceeds the threshold, log flow control is

LFB(Load from Configura OMU and tion Enumerati write Managem on Type flash), ent CL(Consu lt Load) NORMM ODE(Nor mal Mode), RAPMOD ENOSER V(Rapid O&M of Enumerati Mode<No BTS on Type service>), RAPMOD ERESSE RV(Rapid Mode<Re serve BCCH

GSM Flow Control

Interval Type

30~100

Packet queue usage threshold for log flow control. When the average SET Log packet LOGCTH FCMSGQ GBFDcontrol BSC6900 queue D THD(Opti 111705 threshold usage of onal) sliding windows reaches or exceeds the threshold, log flow control is Whether the SCTP is bound ADD to a LOGPOR Logic Port SCTPLN logical BSC6900 None TFLAG Flag K(Mandat port. For ory) details, see "ADD IPLOGIC PORT". Logical port No. bound by the SCTP. ADD For LOGPOR Logic Port SCTPLN BSC6900 None details, TNO No. K(Mandat see the ory) parameter "Logic port No." of the "ADD Logical port slot No. bound by the ADD SCTP. LOGPOR Logic Port SCTPLN For BSC6900 None TSN Slot No. K(Mandat details, ory) see the parameter "Slot No." of the "ADD IPLOGIC

GSM Flow Control

Interval Type

30~100

None

NO(NO), Enumerati YES(YES on Type )

None

Interval Type

0~988

None

Interval Type

0~5,8~27

CPU usage threshold for recovery from log flow control. SET When the Log LOGRTH FCCPUT average GBFDrestore BSC6900 D HD(Optio CPU 111705 threshold nal) usage of sliding windows is lower than the threshold, log flow control is triggered. Packet queue usage threshold for recovery from log flow control. SET When the Log LOGRTH FCMSGQ average GBFDrestore BSC6900 D THD(Opti packet 111705 threshold onal) queue usage of smooth windows is lower than the threshold, log flow control is triggered.

GSM Flow Control

Interval Type

30~100

GSM Flow Control

Interval Type

30~100

LOGSW

Log control switch

Whether SET to control GBFDBSC6900 FCSW(O the log 111705 ptional) flow

GSM Flow Control

Enumerati ON, OFF on Type

LOGTYP Log File E Type

COL The log GBFDBSC6900 LOG(Man type to be 111203 datory) collected.

O&M of BSC

Bit Field Type

STR BTSLOG( Mandator LOGTYP y) Log Type BSC6900 E ULD BTSLOG( Mandator y)

SET Longitude LONGIDE GCELLLC Decimal BSC6900 CI S(Mandat Part ory)

Type of the log. "COMLO G" indicates a common log. "CMPLO G" indicates a Decimal value when the longitude where a cell is located is indicated in the format of degree

PFM_RE SULT, HOST_P FM_RES ULT, ACTIVE_ DEF_ME AS_FILE, STANDB Y_DEF_M EAS_FIL E, PFM_SWI TCHS, HISTORY _ALARM, HISTORY _FAULT, ALM_SYS TEM_CF G, SECURIT Y_LOG, OPT_LO G, OMU_LO G, BSC_CF G_MML, CELL_BA SIC_INF O, BSC_SE RIES_NO

GBFD111202

O&M of BTS

COMLOG (Common Enumerati Log), on Type CMPLOG (Compres s Log)

GBFD115402

BSSBased String LCS (Cell Type ID + TA)

None

SET Longitude LONGIDE GCELLLC Degree BSC6900 GREE S(Mandat Part ory)

SET LONGIIN Longitude GCELLLC BSC6900 T Int Part S(Mandat ory)

SET Longitude LONGIMI GCELLLC Minute BSC6900 NUTE S(Mandat Part ory)

Longitude SET LONGISE Second GCELLLC CONDDE BSC6900 Decimal S(Mandat CI Part ory)

Value of the degree part when the latitude is indicated in the format of degree_m inute_sec ond Integer value when the longitude where a cell is located is indicated in the format of degree Value of the minute part when the longitude is indicated in the format of degree_m inute_sec ond Decimal value of the second part when the longitude is indicated in the format of degree_m inute_sec ond

GBFD115402

BSSBased Interval LCS (Cell Type ID + TA)

0~180

GBFD115402

BSSBased Interval LCS (Cell Type ID + TA)

0~180

GBFD115402

BSSBased Interval LCS (Cell Type ID + TA)

0~59

GBFD115402

BSSBased Interval LCS (Cell Type ID + TA)

0~9

SET Longitude LONGISE GCELLLC Second BSC6900 CONDINT S(Mandat Int Part ory)

GPS ADD LONGITU antenna BSC6900 GPS(Man DE longitude datory) GPS ADD LONGITU antenna BSC6900 GPS(Man DESEC longitude datory)

Integer value of the second part when the longitude is indicated in the format of degree_m inute_sec ond Latitude of the GP receiver antenna Latitude of the GPS receiver antenna

GBFD115402

BSSBased Interval LCS (Cell Type ID + TA)

0~59

MRFD210502

BSC/RNC Interval Clock Type

18000000 0~180000 000 None

MRFD210502

BSC/RNC String Clock Type

LoopLeve Loop l Level

STR MRFDBSC6900 BTSTST( Loop level 210301 Optional)

Configura tion Interval Managem Type ent

1~3

Loop type 1. Local loop:Mak e loop test on the local board at system side, while the system platform will send test frames. STR 2. LOOPMO Loopback FRPORT Remote BSC6900 DE Type LOOP(Ma loop:The ndatory) remoteloop will be made by the device on the other side of the local board. In this case, the local board don't need to make loop

GBFD118611 GBFD118622

BYLOCAL Abis IP (By Local over Loop), Enumerati E1/T1 BYREMO on Type A IP over TE(By E1/T1 Remote Loop)

Loop LOOPSW Detect Switch

SET Loop BSC6900 E1T1(Opti Detect onal) Switch

GBFD118611 GBFD118622

Abis IP over Enumerati OFF(OFF E1/T1 on Type ), ON(ON) A IP over E1/T1

LOP Loopback LOOPTY LAPDLNK GBFDLoop type BSC6900 type of PE (Mandator 111203 LAPD link y)

O&M of BSC

LOOPTY PE_TDM( Line Loop), LOOP_TY Enumerati PE_LVDS on Type (LVDS Loop), LOOPTY PE_MCC( MCC

When the load of an SDCCH on the TRX that is in loose frequency IBCA reuse and LOOSES SET Loose Trx is in the DCCHLO GCELLC GBFDSDCCH BSC6900 compatibl ADTHRE HMGAD( 117002 Load e band of D Optional) Threshold the BCCH is lower than this threshold, the SDCCH is preferably allocated.

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~100

LOPDIR

STR Loop CALLRES BSC6900 Direction LOP(Man datory)

Direction of an GBFDexternal 111203 voice loop

O&M of BSC

MSC(MS C Enumerati Direction), on Type MS(MS Direction)

LOPLOC

Loop Position

Loopback point. There are 14 loopback points. Whether a loopback point is available depends on the subrack configurat STR ion mode CALLRES in the GBFDBSC6900 LOP(Man BSS and 111203 datory) the transmissi on mode of each interface. The details are as follows: NSS Interface Unit: indicates the A interface board in

O&M of BSC

NSSAINT F(NSS Interface Unit), NSSTCT OABIS(N SS TC(Near Abis Interface)) , NSSTCT OA(NSS TC(Near A Interface)) Enumerati , on Type NSSTNU TOABIS( NSS TNU(Near Abis Interface)) , NSSTNU TOA(NSS TNU(Near A Interface)) , NSSATE RINTF(N SS Ater Interface

LOPT

Loopback type No loop: Cancel loop back Remote loop: Remote loop back Line remote loop: Remote loop back Local SET loop: E1T1LOP Local loop Loop type BSC6900 None (Mandator back y) Payload loop: Remote Loop back on all E1/T1 port time slots except TS0 Single channel local loop: Local Loop back on a

None

NO_LOO P(No loop), REMOTE _LOOP(R emote loop), LINE_RE M_LOOP( Line remote loop), LOCAL_L OOP(Loc al loop), Enumerati PAYLOA on Type D_LOOP( payload loop), SIN_CHN _LOC(sin gle channel local loop), SIN_CHN _REM(sin gle channel remote loop)

LOPT

Loop type.

SET OPTLOP( Loopback BSC6900 None Mandator type y)

None

NO_LOO P(NO_LO OP), LOCAL_L OOP(LO Enumerati CAL_LO on Type OP), REMOTE _LOOP(R EMOTE_ LOOP)

Loop LOPTIME Time

STR CALLRES BSC6900 LOP(Opti onal)

Time of an GBFDexternal 111203 voice loop

O&M of BSC

Interval Type

60~600

Number of suspensio n periods after the bandwidth adjustme nt is performe d based on the packet drop ratio. This parameter Suspend ADD specifies times LOSTSU IPLOGIC the delay after BSC6900 None STM PORT(Op statistics bandwidth tional) periods in adjusted which the bandwidth is not adjusted when the bandwidth adjustme nt function of the logical port is triggered due to the change of

None

Interval Type

1~100

Low-level LOWLEV SET Sublink SUBRES GCELLS Resource BSC6900 PREEMP OFT(Opti Preempt TFLG onal) Switch

LOWLEV SUBRES PREEMP TFLG

Low Lev Sub Res Preempt Flag

SET BTSFLEX BSC6900 ABISPAR A(Optiona l)

Whether to permit the preemptio n of lowerlevel sublink resources . If the value of this parameter is YES, a CS domain service GBFDcan preempt 117301 the sublink resources of the PS domain services on the lowerlevel BTS of the cascaded BTSs when the CS domain service The CS services are preferred. This parameter indicates that the CS services are GBFDpermitted 117301 to preempt the dynamic Abis resources on the sublink of the current

Flex Abis

Enumerati NO(No), on Type YES(Yes)

Flex Abis

NO(NO), Enumerati YES(YES on Type )

Whether to permit Diversity SET the low LOWNOI LNA GCELLO BSC6900 noise SESWH Bypass THBASIC amplifier Permitted (Optional) (LNA) bypass

GBFD111202

O&M of BTS

Enumerati OFF(Off), on Type ON(On)

Whether to assign overlay Allocate LOWRXL SET channels OL EVOLFO GCELLC in an IUO GBFDChannel BSC6900 RBIDSWI HMGAD( cell based 113201 Based on TCH Optional) on the RX Level receive level conditions

Concentri Enumerati OFF(Off), c Cell on Type ON(On)

Whether to power off the TRX in the case of overlow temperatu re of the BTS cabinet. If this parameter is set to "Yes", the Low BTS Temperat SET powers LOWTEM ure BTSAPM off the GBFDPLOADP StartLoad BSC6900 UBP(Opti TRX and 111202 WROFF Power-off onal) reports a Allowed "Load State Power Off Alarm" to protect the TRX in the case of overlow temperatu re of the BTS cabinet. When the cabinet temperatu

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

Whether to power off the TRX of a BTS when the temperatu re of the BTS cabinet is too low. Low In multiTemperat SET mode LOWTEM ure BTSDPM scenario, GBFDPLOADP StartLoad BSC6900 UBP(Opti the value 111202 WROFF Power-off onal) of this Allowed parameter State in one mode must be the same as the value of the correspon ding parameter in another STR TRANSP Loopback GBFDBSC6900 ERFTST( mode 111202 Mandator y)

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

Loop LPBKMO Back DE Mode

O&M of BTS

E1(E1 Loopback ), Enumerati TIMESLO on Type T(Timeslo t Loopback )

LPN

IP Logic Port No.

Number of the IP ADD logical IPPATH( BSC6900 port that Mandator carries y) the IP path

GBFD118605

IP QOS

Interval Type

0~988

LPN

ADD Logical Logic port IPLOGIC BSC6900 port No. PORT(Op number tional)

None

None

Interval Type

0~988,10 24~1535

LPN

SET Logical Logic port BSC6900 BTSIP(Ma port No. ndatory) number

None

None

Interval Type

0~988,10 24~1535

LPNSN

IP Logic Port Slot No.

Number of the IP ADD logical IPPATH( BSC6900 port that Mandator carries y) the IP path

GBFD118605

IP QOS

Interval Type

0~5,8~27

Type of LPNTYPE the logic port

ADD Type of IPLOGIC BSC6900 logical PORT(Ma port ndatory)

None

None

Hub(Hub) Enumerati , on Type Leaf(Leaf )

Link LQCMOD Quality E Control Mode

SET GCELLE BSC6900 GPRSPA RA(Optio nal)

LSDF

SET Load BTSAPM Shutdown BSC6900 UBP(Opti Flag onal)

It is applicable to the radio transmissi on environm ent to improve the link quality. Link adaptatio n (LA) indicates adjusting the coding mode of the channel dynamical ly according to the transmissi on quality of the link. The link transmissi on quality is measured by the Whether to enable power shutdown upon low voltage of the battery. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode.

GBFD114201

EGPRS

Enumerati IR(IR), on Type LA(LA)

GBFD111202

O&M of BTS

DISABLE( DISABLE) Enumerati , on Type ENABLE( ENABLE)

LSDV

Load power-off voltage threshold. If "Load Shutdown Flag" is set to "Enable" and the load voltage is lower than the value of SET this Load BTSAPM parameter GBFDShutdown BSC6900 UBP(Opti , the load 111202 Voltage onal) is automatic ally powered off. In multimode scenario, the value of this parameter in one mode must be the same as the

O&M of BTS

Interval Type

350~556

Third SET action LSRTRD LDR Third BSC6900 LDR(Opti taken for onal) load control

GBFD118601 GBFD117301

CLOSE(C lose), PSDOWN (PS Downspe eding), Abis over AMRC(A Enumerati IP MRC), on Type Flex Abis CSPH(CS Preferenc e TCHH), CSFHHO( CS TCHFTCHH HO) EXCLUD E(Exclude O&M of List BSC Comman Enumerati Security d), on Type Managem INCLUDE ent (Include List Comman

Whether Include EXP LSTCMD List BSC6900 LOG(Opti Comman onal) d

Whether to include the list command

GBFD111203 MRFD210305

Query results can be CMP Result list displayed MRFDLstFormat BSC6900 TBLDATA format vertically 210301 (Optional) or horizontall y EXP BTSIPPA RA(Optio nal) EXP BTSVLAN (Optional) EXP BTSDEVI P(Optiona Result Format of l) LSTFOR MRFDList BSC6900 EXP the result MAT 210301 Format BTSPPPL list NK(Optio nal) EXP BTSMPG RP(Optio nal) EXP BTSMPL NK(Optio nal)

HORIZO NTAL(HO Configura RIZONTA tion Enumerati L), Managem on Type VERTICA ent L(VERTIC AL)

HORIZO NTAL(HO Configura RIZONTA tion Enumerati L), Managem on Type VERTICA ent L(VERTIC AL)

LT

LOD Loading Load type BSC6900 BRD(Opti type onal)

MRFD210401

APPLICA TION(App lication Program), SCNDCP U_PROG( Secondar y Thread BSC/RNC Program), Software Enumerati BOOTRO Managem on Type M(BOOT ent ROM Program), DATA(Dat a file), DSP(DSP Program), FAN(Fan Program) OPTLOG( O&M of Operation BSC Enumerati Log), Security on Type SECLOG( Managem Security ent Log)

LT

SET LOGLIMI Type of Log Type BSC6900 T(Mandat the log ory)

GBFD111203 MRFD210305

LT

EXP Type of Log Type BSC6900 LOG(Man the log datory)

GBFD111203 MRFD210305

OPTLOG( O&M of Operation BSC Enumerati Log), Security on Type SECLOG( Managem Security ent Log)

LTCP

Temperat ure control threshold for low temperatu re. When the ambient temperatu re is less than "Low Temperat ure Critical Low SET Point", the Temperat BTSDHE temperatu GBFDure BSC6900 UBP(Opti re control 111202 Critical onal) system Point needs to control the temperatu re difference between the air inlet and air outlet, and that between the air inlet and ambient

O&M of BTS

Interval Type

-99~70

Lower SET LTEMTH Temperat BSC6900 BTSEXD( D ure Optional) Threshold

Uplink SET Long-term LTFERLO GCELLC FER BSC6900 WTH CAMR(O Lower ptional) Threshold

Lower temperatu re threshold for the environm ent alarm box to report an alarm indicating that the ambient temperatu re is too low. If the ambient temperatu re of the BTS is lower than this threshold, the environm ent alarm box reports the alarm. In multimode scenario, the value of this Lower voice quality threshold associate d with the automatic adjustme nt of the AMR handover uplink threshold; The value of this parameter must be smaller than or equal to the value of Uplink Long-term FER Target.

GBFD111202

O&M of BTS

Interval Type

-99~99

GBFD115506

AMR Coding Rate Interval Threshold Type Adaptive Adjustme nt

2~255

Target voice quality value associate Uplink SET d with the LTFERTG Long-term GCELLC GBFDBSC6900 automatic T FER CAMR(O 115506 adjustme Target ptional) nt of the uplink threshold of AMR handover

AMR Coding Rate Interval Threshold Type Adaptive Adjustme nt

2~255

Upper voice quality threshold Uplink associate SET Long-term d with the LTFERUP GCELLC GBFDFER BSC6900 automatic TH CAMR(O 115506 Upper adjustme ptional) Threshold nt of the AMR handover uplink threshold

AMR Coding Rate Interval Threshold Type Adaptive Adjustme nt

2~255

Factor of uplink threshold adjustme nt. It indicates Uplink SET the linear LTTHADJ Threshold GCELLC relation GBFDBSC6900 FA Adjust CAMR(O between 115506 Factor ptional) the threshold adjustme nt value and the logarithmi c FER.

AMR Coding Rate Interval Threshold Type Adaptive Adjustme nt

2~255

Number of DSPs LVDS252 with 252 DSPNUM LVDS Links

Number of DSPs, each of which carries 252 LVDS links on SET the DPUd DSPLVD or DPUb GBFDBSC6900 SMODE( board. If 110000 Mandator this y) parameter is set to 0, every DSP carries 192 LVDS links by

Interval Type

0~12

SET BTSRXU Lvl1Vswr Lvl1 Vswr BSC6900 BP(Optio nal)

SET BTSRXU Lvl2Vswr Lvl2 Vswr BSC6900 BP(Optio nal)

The level 1 Voltage Standing Wave Ratio (VSWR) threshold. When the VSWR is higher than this parameter , the TRX will report a level-1 VSWR alarm. At this time, the BTS can provide services but its coverage rate decrease The level 2 Voltage Standing Wave Ratio (VSWR) threshold. When the VSWR is higher than this parameter , the TRX will report a level-2 VSWR alarm. At this time, the BTS disables power amplificati on and fails to provide services.

GBFD111202

O&M of BTS

14(1.4), 15(1.5), 16(1.6), 18(1.8), 20(2.0), 22(2.2), Enumerati 24(2.4), on Type 26(2.6), 28(2.8), 30(3.0), 33(3.3), 36(3.6), 88(8.8)

GBFD111202

O&M of BTS

18(1.8), 20(2.0), 22(2.2), 24(2.4), 26(2.6), 28(2.8), Enumerati 30(3.0), on Type 32(3.2), 35(3.5), 38(3.8), 41(4.1), 45(4.5), 88(8.8)

LVSDF

Whether "Shutdow n Voltage" is valid. In multimode base station Low SET scenario, Voltage BTSAPM the value BSC6900 Shutdown UBP(Opti of this Flag onal) parameter in different modes must be the same for the same multi-

GBFD111202 GBFD111601

O&M of DISABLE( BTS DISABLE) BTS Enumerati , Power on Type ENABLE( Managem ENABLE) ent

M3UA M3UASR service VPN listening port No.

SET SCTPSR BSC6900 VPORT(O ptional)

Number of the M3UA service listening port

GBFD118602

A over IP

Interval Type

1024~655 35

MAC

MAC Address

ADD XPUVLA BSC6900 N(Mandat ory)

MAC address of the VLAN

MRFD210301

Configura tion Interval Managem Type ent

0~8191

When the number of error frames on the MAC MAC layer SET Frame reaches MACEAA BTSETH Error BSC6900 the value T PORT(Op Alarm of this tional) Threshold parameter , the frame error alarm is generated When the number of error frames on the MAC MAC layer Frame SET decrease MACEAD Error BTSETH BSC6900 s to the T Alarm PORT(Op value of Clearance tional) this Threshold parameter , the frame error alarm is

GBFD118630

Ethernet OAM

Interval Type

0~100

GBFD118630

Ethernet OAM

Interval Type

0~100

ARFCN MACODI Coding NGMOD Scheme

Coding mode in which an ARFCN is sent to an MS during an assignme nt or handover. If the parameter is set to CA_MA, an SET ARFCN is GCELLS indicated GBFDBSC6900 OFT(Opti through 113701 onal) the CA and MA informatio n contained in an assignme nt or handover command . If the parameter is set to Frequenc y_List, an ARFCN is

CA_MA(C A+MA), Frequenc Frequenc y_List(Fre y Hopping quency (RF Enumerati List), hopping, on Type OPTIMIZ baseband ED_CA_ hopping) MA(Optim ized CA+MA)

MAIDX

ADD ETHMA( Mandator y) ADD ETHMEP( Mandator MA Index BSC6900 y) PING MAC(Man datory) TRC MAC(Man datory)

Power MAINBC Derating CHPWDT Active ACTCHE Channel N Enabled

SET GCELLO BSC6900 THEXT(O ptional)

Identifies a maintena nce group. Maintena nce group: maintena nce alliance (MA), which is a compone nt of the maintena nce None domain (MD). Maintena nce domain is an Ethernet or a compone nt of an Ethernet in which the connectivi ty failure managem ent is When this parameter is set to YES, the BSC6900 is allowed to reduce the GBFDtransmit 111609 power of the nonBCCH timeslots on the BCCH TRX.

None

Interval Type

0~499

Enhanced BCCH Power Enumerati NO(No), Consumpt on Type YES(Yes) ion Optimizati on

MAINBC Power CHPWRD Derating TEN Enabled

This parameter specifies whether to enable the Enhanced BCCH Power Consumpt ion Optimizati on feature. Generally, SET the BCCH GCELLO TRX GBFDBSC6900 THEXT(O transmits 111609 ptional) signals at the maximum transmit power. When this parameter is set to YES, the BSC6900 is allowed to reduce the transmit power of the nonThis

Enhanced BCCH Power Enumerati NO(No), Consumpt on Type YES(Yes) ion Optimizati on

parameter specifies the end time of the period SET during MAINBC Power GCELLO which the GBFDCHPWRD Derating BSC6900 THEXT(O power of 111609 TETIME End Time ptional) the nonBCCH timeslots on the BCCH TRX is derated.

Enhanced BCCH Power Compoun Consumpt hour, min d Type ion Optimizati on

MAINBC Power CHPWRD Derating TRANGE Range

SET GCELLO BSC6900 THEXT(O ptional)

Power MAINBC Derating CHPWRD Start TSTIME Time

SET GCELLO BSC6900 THEXT(O ptional)

BTS ADD MAINDEV Interface BTSESN( BSC6900 TAB Board Bar Mandator Code 1 y)

This parameter specifies the range of power derating over the nonBCCH timeslots on the BCCH TRX. This parameter specifies the start time of the period during which the power of the nonBCCH timeslots on the BCCH TRX is derated. Bar code 1 of the interface board of the BTS. This parameter is the electronic serial number of the active PTU board. An electronic serial number uniquely identifies an PTU board. This parameter is set before delivery.

GBFD111609

Enhanced BCCH Power Interval Consumpt Type ion Optimizati on

0~15

GBFD111609

Enhanced BCCH Power Compoun Consumpt hour, min d Type ion Optimizati on

GBFD118630

Ethernet OAM

String Type

None

Bar code ADD 1 of the MAINDEV PTU Main BTSAUT GBFDBSC6900 BTS TAB Dev. Tab OPLAN(M 118601 interface andatory) board Number of main location group. Each cell contains only one main location group. Number of the port to which the active OML of the BTS is connecte Main version No. of the TMU board software. It is configure d according to the actual Mobile allocation index offset 1. Start frequency number, which is the number of the frequency where frequency hopping starts

Abis over String IP Type

None

Main MAINLOC Location GRPNO Group No.

ADD BTSBIND BSC6900 LOCGRP( Mandator y)

GBFD510104

Multi-site Interval Cell Type

0~35

MAINPO RTNO

ADD Main Port BSC6900 BTS(Opti No onal)

MRFD210206

Tree Interval Topology Type

0~1

MainVer

Main Version No.of TMU

SET BTSAUT BSC6900 ODLDAC TINFO(M andatory)

GBFD111202

O&M of BTS

Interval Type

0~9999

MAIO1

MAIO 1

SET GCELLM BSC6900 AIOPLAN (Optional)

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

MAIO10

MAIO 10

SET GCELLM BSC6900 AIOPLAN (Optional)

MAIO11

MAIO 11

SET GCELLM BSC6900 AIOPLAN (Optional)

MAIO12

MAIO 12

SET GCELLM BSC6900 AIOPLAN (Optional)

Mobile allocation index offset 10. Start frequency number, which is the number of the frequency where frequency hopping starts Mobile allocation index offset 11. Start frequency number, which is the number of the frequency where frequency hopping starts Mobile allocation index offset 12. Start frequency number, which is the number of the frequency where frequency hopping starts

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

MAIO2

MAIO 2

SET GCELLM BSC6900 AIOPLAN (Optional)

MAIO3

MAIO 3

SET GCELLM BSC6900 AIOPLAN (Optional)

MAIO4

MAIO 4

SET GCELLM BSC6900 AIOPLAN (Optional)

Mobile allocation index offset 2. Start frequency number, which is the number of the frequency where frequency hopping starts Mobile allocation index offset 3. Start frequency number, which is the number of the frequency where frequency hopping starts Mobile allocation index offset 4. Start frequency number, which is the number of the frequency where frequency hopping starts

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

MAIO5

MAIO 5

SET GCELLM BSC6900 AIOPLAN (Optional)

MAIO6

MAIO 6

SET GCELLM BSC6900 AIOPLAN (Optional)

MAIO7

MAIO 7

SET GCELLM BSC6900 AIOPLAN (Optional)

Mobile allocation index offset 5. Start frequency number, which is the number of the frequency where frequency hopping starts Mobile allocation index offset 6. Start frequency number, which is the number of the frequency where frequency hopping starts Mobile allocation index offset 7. Start frequency number, which is the number of the frequency where frequency hopping starts

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

MAIO8

MAIO 8

SET GCELLM BSC6900 AIOPLAN (Optional)

MAIO9

MAIO 9

SET GCELLM BSC6900 AIOPLAN (Optional)

Feed Tri. 0 TMA SET MAJORA Over BTSDAT BSC6900 LMUP0 Critical UBP(Opti Alarm onal) Threshold

Mobile allocation index offset 8. Start frequency number, which is the number of the frequency where frequency hopping starts Mobile allocation index offset 9. Start frequency number, which is the number of the frequency where frequency hopping starts Critical alarm threshold against excessive TMA feed current of feed tributary 0. When the actual current is greater than the specified value, a TMA feed current critical alarm is generated .

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

GBFD117002

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~11

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

Critical alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 1 TMA SET 1. When MAJORA Over BTSDAT the actual BSC6900 LMUP1 Critical UBP(Opti current is Alarm onal) greater Threshold than the specified value, the TMA feed current critical alarm is generated . Critical alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 2 TMA SET 2. When MAJORA Over BTSDAT the actual BSC6900 LMUP2 Critical UBP(Opti current is Alarm onal) greater Threshold than the specified value, the TMA feed current critical alarm is generated .

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

Critical alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 3 TMA SET 3. When MAJORA Over BTSDAT the actual BSC6900 LMUP3 Critical UBP(Opti current is Alarm onal) greater Threshold than the specified value, the TMA feed current critical alarm is generated . Critical alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 4 TMA SET 4. When MAJORA Over BTSDAT the actual BSC6900 LMUP4 Critical UBP(Opti current is Alarm onal) greater Threshold than the specified value, the TMA feed current critical alarm is generated .

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

Critical alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 5 TMA SET 5. When MAJORA Over BTSDAT the actual BSC6900 LMUP5 Critical UBP(Opti current is Alarm onal) greater Threshold than the specified value, the TMA feed current critical alarm is generated . ADD ETHMA( Mandator y) Name of PING MANAME MA Name BSC6900 BTSCFM( the MA Mandator y) TRC BTSCFM( ADD BTSETH MA(Mand atory) ADD BTSETHL MANAME MA Name BSC6900 CMEP(Ma ndatory) ADD BTSETH RMMEP( Mandator y)

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

GBFD111202

O&M of BTS

String Type

None

Name of the maintena nce associatio n.

GBFD118630 MRFD210301

Ethernet OAM Configura String tion Type Managem ent

None

MASK

Subnet mask

Subnet mask correspon ADD ding to PPPLNK( BSC6900 the local None Mandator IP y) address of the PPP link Subnet ADD mask of MPGRP( BSC6900 the MP Mandator group in y) BSC. GBFD118611 GBFD118622

None

IP Address Type

None

MASK

Subnet mask

Abis IP over IP E1/T1 Address A IP over Type E1/T1

None

MASK

Subnet mask

MASK

Packet source mask

ADD ETHIP(M Subnet andatory) GBFDBSC6900 mask of ADD 118630 the board EMSIP(M andatory) Mask of the source IP ADD network ICMPGU BSC6900 segment None ARD(Man of the datory) packet against the ICMP ADD IPRTBIN D(Mandat Subnet ory) BSC6900 mask ADD ETHTRKI P(Mandat ory) ADD Subnet GCBSAD BSC6900 mask of DR(Mand the CBC atory)

Ethernet OAM

IP Address Type

None

None

IP Address Type

None

MASK

Subnet mask

None

None

IP Address Type

None

MASK

Mask

GBFD113601

Short Message IP Service Address Cell Type Broadcast (TS23)

None

MASK

IP Mask

SET BTSETH PORT(Op IP subnet GBFDtional) BSC6900 mask of a 118601 IMP BTS port BTSDEVI P(Optiona l) ADD BTSPPPL NK(Mand atory) BSC6900 IMP BTSPPPL NK(Mand atory)

IP Abis over Address IP Type

None

MASK

Subnet Mask

Subnet mask of GBFDBTS PPP 118611 link.

Abis IP over E1/T1

IP Address Type

None

MASK

Subnet Mask

ADD BTSMPG RP(Mand atory) BSC6900 IMP BTSMPG RP(Mand atory)

Subnet mask of BTS MLPPP Group.

GBFD118611

Abis IP over E1/T1

IP Address Type

None

IP address of the main clock Master ADD server. It MASTERI Clock BTSAUT must be a GBFDBSC6900 PADDR Server IP OPLAN(M legal 118606 Address andatory) A/B/C type address but not a broadcast address It must be the valid address of the A, SET B, or C Clock MASTERI BTSIPCL type and GBFDServer IP BSC6900 PADDR KPARA(M cannot be 118606 Address 1 andatory) the broadcast address or network

Clock over IP

IP Address Type

None

Clock over IP

IP Address Type

None

MAX Up MAXADJ Adj. PC PCVAL Value by Qual.

Step of upward power adjustme SET nt GCELLP GBFDBSC6900 according WR2(Opti 110703 to the onal) quality of the received signals

Enhanced Power Interval Control Type Algorithm

0~32

If the number of the associatio n retransmi ssions exceeds ADD this value, Associatio MAXASS SCTPLN the n max BSC6900 OCRETR K(Optiona parameter retrans l) is deleted automatic ally. The value must be greater than Path max retrans. Maximum bandwidth ADD for Max IPLOGIC dynamic MAXBW bandwidth BSC6900 PORT(Op adjustme [64kbps] tional) nt at the logical port

GBFD118602

A over IP

Interval Type

0~254

GBFD118609 MRFD210103

IP Fault Detection Based on Interval BFD Type Link aggregati on

1~1562

Number of consecuti ve intracell handover s allowed in a cell. When the interval between two intracell handover s is lower MAX SET than a MAXCNT Consecuti GCELLH certain BSC6900 NUM ve HO OAD(Opti time Times onal) threshold, these two intra-cell handover s are considere d consecuti ve. When a certain number of intra-cell handover s occur consecuti vely, intraMaximum

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~20

number of Retry attempts SET Times of to resend MaxDlAss BSCPSS Downlink GBFDthe RetryTim BSC6900 OFTPAR TBF downlink 114101 es A(Optiona Reassign assignme l) ment nt message s Number Retry of SET Times of attempts BSCPSS MaxDlEst Downlink to reBSC6900 OFTPAR RetryNum TBF establish A(Optiona Establish the l) ment downlink TBF This parameter specifies MAXDRO SET Max Drop the PPWRTH BTSBAKP Power BSC6900 largest RESHOL WR(Optio Threshold step of D nal) each TRX power reduction.

GPRS

Interval Type

0~5

GBFD114101

GPRS

Interval Type

0~5

GBFD111605

Active Backup Power Control

Interval Type

0~20

ADD BTSAUT OPLAN(M Maximum andatory) MAXFQN TRX BSC6900 SET UM Number BTSAUT OPLANC FG(Optio nal)

Maximum number of TRXs that can be configure d for one cell. For the BTS3900 B GSM, when the "Frequen cy and BSIC Plan Switch" is ON, the "Maximu m TRX Number" (one or two, one by default) can be selected. For the BTS3900 E GSM, when the "Capacity and Coverage Optimize

GBFD510701 GBFD510601

Compact BTS Automatic Configura tion and Interval Planning Type PICO Automatic Configura tion and Planning

1~2

Maximum number of TRXs that can be configure d for one cell. For the BTS3900 B GSM, when the "Frequen cy and BSIC Plan SET Switch" is Maximum BTSAUT MAXFQN GBFDON, the TRX BSC6900 OPLANC UM1 "Maximu 510702 Number FG(Optio m TRX nal) Number" (one or two, one by default) can be selected. For the BTS3900 E GSM, when the "Capacity and Coverage Optimize Maximum ADD MAXFRA Frame BSC6900 IPMUX(O MELEN Length[by ptional) te] Maximum multiplexi GBFDng frame 118605 length.

Compact BTS Interval Automatic Type Capacity Planning

1~2

IP QOS

Interval Type

24~1031

Maximum number of BTSs that Max BTS are SET MAXLOA Num of allowed to OTHSOF GBFDDBTSNU Parallel BSC6900 concurren TPARA(O 111202 M Software tly ptional) Load download software under a BSC

O&M of BTS

Interval Type

50~200

The value of this parameter cannot be less than the maximum PPPMUX sub-frame length (MUXMA XSFL). This parameter can be PPP mux associate ADD MAXMFL max muxd with the BSC6900 PPPLNK( EN frame maximum Optional) length segment length of the MP to control whether to segment the multiplexe d MP. To enable the PPPMUX, the number of sub-

GBFD118604 GBFD118610

Abis MUX UDP MUX for Interval A Type Transmis sion

1~1500

Maximum PPP mux ADD length of MAXMFL max muxBSC6900 MPGRP( the PPP EN frame Optional) multiplexi length ng frame

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

1~1500

SET Maximum MaxMissT PWDPOL Retry BSC6900 imes ICY(Optio Times nal)

Maximum number of retries MRFDwhen the 210305 user logs in

Security Interval Managem Type ent

1~255

Maximum SET Max capacity ALMCAP MRFDMAXNUM Alarm Log BSC6900 for storing ACITY(Op 210304 Number the alarm tional) log

Faulty Interval Managem Type ent

10000~15 0000

Diesel MAXOUT Max PUTPOW Output ER Power

SET BTSDPM BSC6900 UBP(Opti onal)

Maximum output GBFDpower of 111202 the diesel

O&M of BTS

Interval Type

1~1000

If the number of the path retransmi ssions exceeds this value, the ADD parameter MAXPAT Path max SCTPLN GBFDBSC6900 is deleted HRETR retrans K(Optiona 118602 automatic l) ally. The value must be smaller than Associatio n max retrans.

A over IP

Interval Type

0~254

Pb Link Check MaxPbLin Max kChkNum TimeOut Number

SET OTHSOF BSC6900 TPARA(O ptional)

SET Maximum MAXPDC GTRXBA Number BSC6900 HNUM SE(Optio of PDCH nal)

Retransmi ssion times of Pb link check (LapdChe ck) message s. When a BSC sends a Pb link check message to an external PCU and fails to receive a response from the external PCU, it retransmit s the message. This parameter indicates the maximum times for the PB link check Maximum number of PDCHs that can be assigned in the TRX

GBFD114101

GPRS

Interval Type

0~100

GBFD113101

PDCH Dynamic Interval Adjustme Type nt

0~8

Maximum SET Rate MAXPDC GCELLP Threshold BSC6900 HRATE SCHM(O of PDCHs ptional) in a Cell

Retry SET MaxPollin Times of BSCPSS gRetryTi Downlink BSC6900 OFTPAR mes TBF A(Optiona Polling l)

Maximum value of the PDCH ratio in a cell. The number of available TCHs and PDCHs in a cell is set to a fixed value. The PDCH ratio is: Number of available PDCHs/( Number of available TCHFs + Number of available static PDCHs). This parameter Maximum number of attempts to resend the polling message s

GBFD114101 GBFD113101 GBFD119303 GBFD119501 GBFD114101 GBFD113101 GBFD119303 GBFD119501

GPRS PDCH Dynamic Adjustme nt Load Sharing Adaptive Adjustme nt of Uplink and Downlink Channels Interval GPRS Type PDCH Dynamic Adjustme nt Load Sharing Adaptive Adjustme nt of Uplink and Downlink Channels

0~100

GBFD114101

GPRS

Interval Type

0~5

MAXPRO Expire MPTDAT Prompt ES Dates

SET Expire PWDPOL BSC6900 Prompt ICY(Optio Dates. nal)

MRFD210305

Security Interval Managem Type ent

1~255

Maximum current coefficient when the battery is charged. When the battery is charged, the maximum current can be 0.01 to 0.99 SET times of MAXREC Charge BTSPMU the GBFDHARGEC Coefficien BSC6900 BP(Optio capacity 111202 URRENT t nal) of the battery cabinet. That is, the charge coefficient is 0.010.99. For example, if the capacity of the battery cabinet is 200 A and

O&M of BTS

1C(0.01C ), 2C(0.02C ), 3C(0.03C ), 4C(0.04C ), 5C(0.05C ), 6C(0.06C ), 7C(0.07C ), 8C(0.08C ), Enumerati 9C(0.09C on Type ), 10C(0.10 C), 11C(0.11 C), 12C(0.12 C), 13C(0.13 C), 14C(0.14 C), 15C(0.15 C), 16C(0.16 C), 17C(0.17 C),

Maximum current coefficient when the battery is charged. When the battery is charged, the maximum current can be 0.05 to 0.25 SET times of MAXREC Charge BTSDPM the GBFDHARGEC Coefficien BSC6900 UBP(Opti capacity 111202 URRENT t onal) of the battery cabinet. That is, the charge coefficient is 0.050.25. For example, if the capacity of the battery cabinet is 200 A and

O&M of BTS

5C(0.05C ), 7C(0.07C ), 10C(0.10 C), 12C(0.12 C), Enumerati 15C(0.15 on Type C), 18C(0.18 C), 20C(0.2C ), 22C(0.22 C), 25C(0.25 C)

Maximum times for a Physical Informatio n message to be transmitte d. When the retransmi ssion times exceeds this Max SET parameter MAXRES Resend GCELLH and the BSC6900 END Times of OAD(Opti BTS still Phy.Info. onal) cannot receive any correct SAMB frame from the MS, the BTS sends a connectio n failure message (including the handover Maximum retransmi ssion for radio priority 1. The 2bit Radio Priority message carried by the MS in Max SET the Retransmi MAXRET GCELLP Packet ssions for BSC6900 RANS1 RACH(Op Channel Radio tional) Request Priority 1 message has four levels of priorities. Level 1 is the highest priority, and level 4 is the lowest

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~255

GBFD119110

Access

1_Times( 1_Times), 2_Times( Enumerati 2_Times), on Type 4_Times( 4_Times), 7_Times( 7_Times)

Max Retransmi MAXRET ssions for RANS2 Radio Priority 2

Max Retransmi MAXRET ssions for RANS3 Radio Priority 3

Maximum retransmi ssion for radio priority 2. The 2bit Radio Priority message carried by the MS in SET the GCELLP Packet BSC6900 RACH(Op Channel tional) Request message has four levels of priorities. Level 1 is the highest priority, and level 4 is the lowest Maximum retransmi ssion for radio priority 3. The 2bit Radio Priority message carried by the MS in SET the GCELLP Packet BSC6900 RACH(Op Channel tional) Request message has four levels of priorities. Level 1 is the highest priority, and level 4 is the lowest

GBFD119110

Access

1_Times( 1_Times), 2_Times( Enumerati 2_Times), on Type 4_Times( 4_Times), 7_Times( 7_Times)

GBFD119110

Access

1_Times( 1_Times), 2_Times( Enumerati 2_Times), on Type 4_Times( 4_Times), 7_Times( 7_Times)

Max Retransmi MAXRET ssions for RANS4 Radio Priority 4

PPP mux MAXSFL max subEN frame length

Maximum retransmi ssion for radio priority 4. The 2bit Radio Priority message carried by the MS in SET the GCELLP Packet BSC6900 RACH(Op Channel tional) Request message has four levels of priorities. Level 1 is the highest priority, and level 4 is the lowest Maximum PPPMUX sub-frame length. If the PPP frame length is larger than this value, the PPPMUX multiplexi ng is performe d. The value of ADD this BSC6900 PPPLNK( parameter Optional) cannot be larger than the maximum multiplexe d frame length wMuxMfl. To enable the PPPMUX, the number of subframes must be

GBFD119110

Access

1_Times( 1_Times), 2_Times( Enumerati 2_Times), on Type 4_Times( 4_Times), 7_Times( 7_Times)

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

1~746

Maximum PPP mux ADD length of MAXSFL max subBSC6900 MPGRP( the PPP EN frame Optional) multiplexi length ng frame

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

1~746

Huawei power control algorithm II divides three quality zones according to the quality of the receive signals. When the MAX SET power is Down MAXSTE GCELLP downward GBFDAdj.Value BSC6900 P0 WR2(Opti ly 110703 Qual.Zon onal) adjusted e0 according to the level, the maximum downward adjustme nt step can vary according to the quality of the received signals. This

Enhanced Power Interval Control Type Algorithm

0~30

Huawei power control algorithm II divides three quality zones according to the quality of the receive signals. When the MAX SET power is Down MAXSTE GCELLP downward GBFDAdj.Value BSC6900 P1 WR2(Opti ly 110703 Qual.Zon onal) adjusted e1 according to the level, the maximum downward adjustme nt step can vary according to the quality of the received signals. This

Enhanced Power Interval Control Type Algorithm

0~30

Huawei power control algorithm II divides three quality zones according to the quality of the receive signals. When the MAX SET power is Down MAXSTE GCELLP downward GBFDAdj.Value BSC6900 P2 WR2(Opti ly 110703 Qual.Zon onal) adjusted e2 according to the level, the maximum downward adjustme nt step can vary according to the quality of the received signals. This

Enhanced Power Interval Control Type Algorithm

0~30

MAXTA

Max TA

This parameter specifies the actual coverage area of a cell. After receiving the channel request message or handover access SET message, GCELLB the BTS BSC6900 ASICPAR determine A(Optiona s whether l) the channel assignme nt or handover is performe d in the cell by comparin g the TA and the value of this parameter Number

GBFD110901 GBFD114001

Adjustme nt of Adaptive Interval Timing Type Advance Extended Cell

0~255

of measure ment SET MAXTAD MAX TA reports GCELLC GBFDROPCAL Drop Call BSC6900 (MRs) CAD(Opti 111004 LFILTER Filter used for onal) averaging the time advance before the Whether to initiate a forcible call drop SET MAXTAD Max TA when the GCELLC GBFDROPCAL Drop Call BSC6900 time CAD(Opti 111004 LSWITCH Switch advance onal) exceeds "MAX TA Drop Call Threshold

Radio Dedicated Interval Channel Type Managem ent

0~31

Radio Dedicated Enumerati OFF(Off), Channel on Type ON(On) Managem ent

Whether the time advance after filtering exceeds the MAXTAD SET MAX TA threshold. ROPCAL GCELLC GBFDDrop Call BSC6900 If the LTHRES CAD(Opti 111004 Threshold threshold HOLD onal) is exceeded ,a forcible call drop is initiated.

Radio Dedicated Interval Channel Type Managem ent

0~255

Maximum STR Maximum MRFDMAXTIME time for BSC6900 POSAVE( positionin 210502 posave Optional) g time.

BSC/RNC Interval Clock Type

1~24

Maximum Number SET MAXTSO of GTRXBA BSC6900 CP Occupied SE(Optio Abis nal) Timeslots

MAXTTL

TRC MAX TTL BSC6900 IPADDR( Optional)

Maximum number of (16 kbit/s) Abis GBFDtimeslots 117301 that the PDCHs can use in the TRX Maximum TTL value of the None sent TRACER T packet

Flex Abis

Interval Type

0~32

None

Interval Type

2~255

MAX Up MAXVAL Adj. PC ADJRX Value by RX_LEV

Step of upward power adjustme SET nt GCELLP GBFDBSC6900 according WR2(Opti 110703 to the onal) quality of the received signals

Enhanced Power Interval Control Type Algorithm

0~32

SET Maximum Maximum MAXVALI PWDPOL MRFDValid BSC6900 Valid DDATES ICY(Optio 210305 Dates Dates. nal) Detection index. The index is a ADD MBFD unique MBFDCH IPRTBIN Check BSC6900 None value KN D(Mandat Index ranging ory) from 0 to 31 if it is not specified. Multi hop Local IP STR MBFDLO BFD address GBFDBSC6900 IPCHK(M CALIP detect for multi- 118609 andatory) local ip hop BFD

Security Interval Managem Type ent

1~999

None

Interval Type

0~511

IP Fault IP Detection Address Based on Type BFD

None

MBR

Multiband report

Used for requestin g the MS to report the measure ment informatio n of SET neighbori GCELLC ng cells in BSC6900 CBASIC( multiple Optional) frequency bands. This parameter is carried in the system informatio n 2ter and 5ter.

GBFD114401 GBFD111101

Multiband Sharing Interval One BSC Type System Informatio n Sending

0~3

For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in several Filter SET consecuti Length for MBSIGNL GCELLH ve GBFDSDCCH BSC6900 EN OFITPEN measure 117501 MEAN_B (Optional) ment EP reports. This parameter indicates the number of enhanced measure ment reports received on a signaling channel used to

Enhanced Measure Interval ment Type Report(E MR)

0~31

Filter SET Length for MBTRAF GCELLH TCH BSC6900 FLEN OFITPEN MEAN_B (Optional) EP

MBTSID

Second BTS Index

COL SYNCINF BSC6900 O(Mandat ory)

For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in several consecuti ve measure ment reports. This parameter indicates the number of enhanced measure ment reports received on a voice channel used to measure Number of the BTS. The BTS is numbered uniquely in a BSC.

GBFD117501

Enhanced Measure Interval ment Type Report(E MR)

0~31

GBFD118201

SoftSynchroni Interval zed Type Network

0~2047

Second MBTSNA BTS ME Name

COL SYNCINF BSC6900 O(Mandat ory)

Name of the BTS. The BTS GBFDis named 118201 uniquely in a BSC.

SoftSynchroni String zed Type Network

None

MCC

MCC

ADD GCNOPE RATOR( Mandator y) ADD GCELL(M andatory) ADD GEXT2G CELL(Ma ndatory) ADD GEXT3G CELL(Ma BSC6900 ndatory) SET FHO(Man datory) ADD BTSAUT OPLAN(M andatory) SET BTSAUT OPLANC FG(Optio nal) ADD GCELLQ UICKSET

Mobile country code. This parameter identifies the country where a MRFDmobile 210301 subscribe r is located, for example, the Chinese MCC is 460.

Configura tion String Managem Type ent

None

MCC1

SET BTSAUT Cell MCC BSC6900 OPLANC FG(Optio nal)

MCCLAS MC PRI S number

ADD BSC6900 MPGRP( Optional)

Local mobile country code (MCC). It is used to identify the GBFDcountry 510702 that the mobile subscribe r belongs to. For example, the MCC of China is 460. Number of MC priorities. This parameter None is valid when the MP group type is MC.

Compact BTS String Automatic Type Capacity Planning

None

None

Interval Type

4,8

MCCLAS MC PRI S Number

ADD BTSMPG RP(Optio nal) BSC6900 IMP BTSMPG RP(Optio nal)

Number of MC priority levels.

GBFD118611

Abis IP over E1/T1

Interval Type

4,8

ADD NCELL(M andatory) Second MCELLID BSC6900 COL Cell Index SYNCINF O(Mandat ory)

Number of the cell. The cell is MRFDnumbered 210301 uniquely in a BSC.

Configura tion Interval Managem Type ent

0~2047

ADD NCELL(M Second andatory) MCELLN Name of Cell BSC6900 COL AME cell 2 Name SYNCINF O(Mandat ory) Cabinet No. of the managem ent board. The managem SET ent board BTSFMU refers to ABP(Opti the TMU onal) or RXU SET that BTSAPM directly UBP(Opti communi onal) cates with Cabinet SET the board. No. of BTSDAT MCN BSC6900 The Managem UBP(Opti configurat ent Board onal) ion of this SET parameter BTSDEM must be UBP(Opti consistent onal) with the SET actual BTSDHE physical UBP(Opti connectio onal) n. Otherwise , the board may not work

GBFD111202

O&M of BTS

String Type

None

GBFD111202

O&M of BTS

Interval Type

0~62

If the MCPA Optimizati on Switch SET MCPA is turned MCPAOP GCELLC GBFDOptimizati BSC6900 on, the TALG HMGAD( 111005 on Switch MCPA Optional) priority update mode is adjusted. Standard GSM SET for the Multi MCSTAN BTSPSU GSM GBFDCarrier BSC6900 DARD FP(Option multi111202 BTS al) carrier Standard BTS ADD ETHMD( Mandator BSC6900 y) ADD ETHMA( Mandator Identifies a maintena None nce domain

Enhanced Channel Enumerati OFF(Off), Assignme on Type ON(On) nt Algorithm

O&M of BTS

CLASS0( Class0), Enumerati CLASS1( on Type Class1), CLASS2( Class2)

MDIDX

MD INDEX

None

Interval Type

0~7

Level of the maintena nce domain.T ADD he priority MDLEVE BTSETH MD Level BSC6900 of the L MD(Optio maintena nal) nce domain ranks from 0 to 7 from ADD ETHMD( Mandator y) MD name of PING MDName BSC6900 NAME BTSCFM( the MD Mandator y) TRC BTSCFM(

GBFD118630 MRFD210301

Ethernet OAM Configura Interval tion Type Managem ent

0~7

GBFD118630

Ethernet OAM

String Type

None

ADD BTSETH MD(Mand atory) ADD BTSETH MA(Mand atory) MDNAME MD Name BSC6900 ADD BTSETHL CMEP(Ma ndatory) ADD BTSETH RMMEP( Mandator y)

Name of the maintena nce domain.

GBFD118630 MRFD210301

Ethernet OAM Configura String tion Type Managem ent

None

Whether to allow the MS to the send SET Allow MR the PS MEASOR GCELLP GBFDComman BSC6900 measure DER SI1(Optio 119102 d or not ment nal) report to the network side ADD GNRNC( BSC6900 Mandator y) Common measure GBFDment 114322 period

Packet System Enumerati NO(No), Informatio on Type YES(Yes) n

Measure MEASPE ment RIOD Period

GSM/WC DMA Interval Load Type Based Handover

1~5

Measure MEASUR ment ETYPE Report Type

Type of the SET measure GCELLC ment BSC6900 CUTRAN report SYS(Opti (MR) onal) reported by the MS

GBFD117501 GBFD110801 GBFD110802

Enhanced Measure ment EnhMeas Report(E Report(En MR) hanced Processin Measure g of ment Measure Enumerati Report), ment on Type ComMeas Report Report(C Preommon processin Measure g of ment Measure Report) ment Report

MEPID

MEP ID

MEPID

MEP ID

MEPTYP MEP E Type

Identifies a maintena nce point in the ADD maintena ETHMEP( GBFDBSC6900 nce Mandator 118630 alliance y) A maintena nce point is an edge Identifies ADD a BTSETHL maintena CMEP(Ma nce end GBFDndatory) 118630 point BSC6900 ADD (MEP) of MRFDBTSETH 210301 a RMMEP( maintena Mandator nce y) associatio The type of the maintena nce point added to the maintena nce ADD group. ETHMEP( LocalMep GBFDBSC6900 Mandator indicates 118630 y) a local maintena nce point and RemoteM ep indicates a remote maintena MP/MC ADD sequence GBFDBSC6900 MPGRP( header 118630 Optional) option

Ethernet OAM

Interval Type

1~1000

Ethernet OAM Configura Interval tion Type Managem ent

1~8191

Ethernet OAM

LocalMep (LocalMe Enumerati p), on Type RemoteM ep(Remot eMep)

MHF

MP/MC list head option

Ethernet OAM

LONG(LO Enumerati NG), on Type SHORT(S HORT)

MHF

ADD BTSMPG RP(Optio MP/MC nal) List Head BSC6900 IMP Option BTSMPG RP(Optio nal)

Frame encapsula tion GBFDformat 118611 supported by MP/MC.

Abis IP over E1/T1

LONG(Lo ng List Enumerati Head), on Type SHORT(S hort List Head)

MINACC RXLEV

Cell SET Reselecti GCELLN BSC6900 on Level C2PARA( Threshold Optional)

MINBW

ADD Min IPLOGIC bandwidth BSC6900 PORT(Op [64kbps] tional)

Minimum receive level for a neighbor cell to become a candidate cell during cell reselectio n. When the receive level of the serving cell is lower than the value of this parameter , it indicates that the normal cell reselectio n level is bad. In this case, the parameter value is Minimum bandwidth for dynamic adjustme nt at the logical port

GBFD116201

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~63

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

1~1562

Selects 3G candidate cells. If the measured value of a 3G neighbori ng cell is ADD Min lower MINECN GEXT3G GBFDEc/No BSC6900 than this OTHRES CELL(Opt 114301 threshold threshold, ional) the 3G neighbori ng cell will be removed from among the 3G candidate cells.

GSM/WC DMA Interval Interopera Type bility

0~49

Min MINOFFS Access ET Level Offset

Minimum receive level offset. An MS can be handed over to a neighbori ng cell only when the ADD downlink G2GNCE level of BSC6900 LL(Option the al) neighbori ng cell is greater than the sum of "Min DL level on candidate Cell" and the value of this parameter .

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

ANT_A ALD SET Current MinorAlm BTSRXU Minor BSC6900 ThdA BP(Optio Alarm nal) Occur Threshold

ANT_B ALD SET Current MinorAlm BTSRXU Minor BSC6900 ThdB BP(Optio Alarm nal) Occur Threshold

Threshold for triggering prompt alarm clearance when the ANT_A tributary antenna current is too heavy. When the actual current is higher than the configure d value, the ALD Current Prompt Alarm clearance is triggered. Threshold for triggering prompt alarm clearance when the ANT_B tributary antenna current is too heavy. When the actual current is higher than the configure d value, the ALD Current Prompt Alarm clearance is triggered.

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

Warning alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 0 TMA SET 0. When MINORAL Over BTSDAT the actual BSC6900 MUP0 Warning UBP(Opti current is Alarm onal) greater Threshold than the specified value, a TMA feed current warning alarm is generated . Warning alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 1 TMA SET 1. When MINORAL Over BTSDAT the actual BSC6900 MUP1 Warning UBP(Opti current is Alarm onal) greater Threshold than the specified value, the TMA feed current warning alarm is generated .

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

Warning alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 2 TMA SET 2. When MINORAL Over BTSDAT the actual BSC6900 MUP2 Warning UBP(Opti current is Alarm onal) greater Threshold than the specified value, the TMA feed current warning alarm is generated . Warning alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 3 TMA SET 3. When MINORAL Over BTSDAT the actual BSC6900 MUP3 Warning UBP(Opti current is Alarm onal) greater Threshold than the specified value, the TMA feed current warning alarm is generated .

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

Warning alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 4 TMA SET 4. When MINORAL Over BTSDAT the actual BSC6900 MUP4 Warning UBP(Opti current is Alarm onal) greater Threshold than the specified value, the TMA feed current warning alarm is generated . Warning alarm threshold against excessive TMA feed current of feed Feed Tri. tributary 5 TMA SET 5. When MINORAL Over BTSDAT the actual BSC6900 MUP5 Warning UBP(Opti current is Alarm onal) greater Threshold than the specified value, the TMA feed current warning alarm is generated .

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

0~2000

ANT_A ALD SET Current MinorClrT BTSRXU Minor BSC6900 hdA BP(Optio Alarm nal) Clear Threshold

ANT_B ALD SET Current MinorClrT BTSRXU Minor BSC6900 hdB BP(Optio Alarm nal) Clear Threshold

Threshold for triggering prompt alarm clearance when the ANT_A tributary antenna current is too heavy. When the actual current is lower than the configure d value, the ALD Current Prompt Alarm clearance is triggered. Threshold for triggering prompt alarm clearance when the ANT_B tributary antenna current is too heavy. When the actual current is lower than the configure d value, the ALD Current Prompt Alarm clearance is triggered.

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

In a direct retry, when the receive level of a neighbori ng cell is no smaller Min than this SET MINPWR Power parameter GCELLH GBFDLEVDIRT Level For BSC6900 , the OCTRL(O 110607 RY Directed neighbori ptional) Retry ng cell can be a candidate cell for the direct retry. The parameter is invalid in handover

Direct Retry

Interval Type

0~63

Minimum time required for a TCH SET TCH to GCELLC MINREST Minimum transform GBFDBSC6900 HMGBASI IMETCH Recovery to a 113001 C(Optiona Time SDCCH l) and then transform back to a TCH

SDCCH Dynamic Interval Adjustme Type nt

60~3600

Selects 3G candidate cells. If the measured value of a 3G neighbori ng cell is ADD Min lower MINRSC GEXT3G RSCP BSC6900 than this PTHRES CELL(Opt threshold threshold, ional) the 3G neighbori ng cell will be removed from among the 3G candidate cells.

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~63

Min interval of STR MINRXIN BFD BSC6900 IPCHK(O T packet ptional) receive [ms]

Minimum interval at which two BFD None packets are received.

None

Interval Type

10~1000

Minimum interval at Minimum ADD which the MINRXIN GBFDRX BSC6900 BTSBFD( BTS TERVAL 118609 Interval Optional) receives BFD packets

IP Fault Detection Interval Based on Type BFD

10~1000

Min interval of STR MINTXIN BFD BSC6900 IPCHK(O T packet ptional) send [ms]

Minimum interval GBFDbetween 118609 sent BFD packets

IP Fault Detection Interval Based on Type BFD

10~1000

Minimum ADD MINTXIN TX BSC6900 BTSBFD( TERVAL Interval Optional)

STR Mirror ETHMIRR MIRROR Dest Port BSC6900 ORPORT DPN No. (Mandator y) STR Mirror ETHMIRR MIRROR Source BSC6900 ORPORT SPN Port No. (Mandator y)

Minimum interval at which the BTS sends BFD packets Mirror destinatio n Ethernet port number Mirror Ethernet port number

GBFD118609

IP Fault Detection Interval Based on Type BFD

10~1000

GBFD118609

IP Fault Detection Interval Based on Type BFD Interval Type

0~11

None

None

0~11

MIRROR Mirror TYPE Type

STR ETHMIRR Mirror BSC6900 ORPORT type (Mandator y) ADD GCNOPE RATOR( Mandator y) ADD GCELL(M andatory) ADD GEXT2G CELL(Ma ndatory) ADD GEXT3G CELL(Ma BSC6900 ndatory) SET FHO(Man datory) ADD BTSAUT OPLAN(M andatory) SET BTSAUT OPLANC FG(Optio nal) ADD GCELLQ UICKSET

None

None

UP(upstre am Enumerati mirror), on Type DOWN(d ownstrea m mirror)

MNC

MNC

Mobile network code. This parameter identifies the public MRFDland 210301 mobile network (PLMN) to which a mobile subscribe r belongs.

Configura tion String Managem Type ent

None

MNC1

SET BTSAUT Cell MNC BSC6900 OPLANC FG(Optio nal)

SET MOCACC MOC BSCFCP ESSCPU Access BSC6900 ARA(Opti RATE CPU Rate onal)

Mobile network code (MNC). It is used to identify the PLMN that the mobile subscribe r belongs Usage threshold of the CPU for calling access. If the usage of the CPU exceeds the threshold, the calling access request is transferre d to other CPU for processin

GBFD510702

Compact BTS String Automatic Type Capacity Planning

None

GBFD111705

GSM Flow Control

Interval Type

50~95

MODE

System clock working mode

Working mode of the system clock. Working modes of the system clock are as follows: (1) MANUAL: In this SET mode, CLKMOD you must MRFDBSC6900 E(Mandat specify a 210502 ory) clock source and prevent the switching of the clock source. (2) AUTO: In this mode, you do not need to specify a clock

MANUAL( Manual Handover ), BSC/RNC Enumerati AUTO(Au Clock on Type to Handover ), FREE(Fre e-run)

MODE

SCTP link work mode. Server mode: BSC6900 starts the listening and waits for the ADD peer to Signalling SCTPLN BSC6900 send the link mode K(Mandat SCTPory) INIT message. Client mode: BSC6900 actively sends the SCTPINIT message.

GBFD118602 GBFD118622

SERVER( SERVER A over IP Enumerati MOD), A IP over on Type CLIENT( E1/T1 CLIENT MOD)

MODE

SET Configure QUICKCF Configura MRFDBSC6900 Mode G(Mandat tion mode 210301 ory) SWP MBSCMO Mode DE(Mand after atory) BSC6900 Switchove CHK r MODEDA TA(Mand atory)

Configura tion Enumerati OFF(OFF Managem on Type ), ON(ON) ent

MODE

Working mode MRFDafter 210301 switchove r

GO(GSM) , Configura UO(UMT tion Enumerati S), Managem on Type GU(GSM ent and UMTS) FIXED(Fil e of a Fixed Size), Enumerati CYCLE(P on Type eriodical Generatio n of New File)

MODE

File Output Mode

SET Mode of GCSFILE BSC6900 file (Mandator output. y)

None

None

MODE

Backup mode

Backup SET mode of BSC6900 MSP(Opti the switch None onal) protection group

None

MODE

Check mode

Working mode of a port. When this parameter is set to CHECK_ ON_STA NDBY_P ORT, the connectivi ty check is performe d on the standby STR GBFDport. BSC6900 IPCHK(O When this 111701 ptional) parameter is set to CHECK_ ON_INDE PENDEN T_PORT, the connectivi ty check is performe d on the independ ent port. When this parameter

MODE1(1 :1 Protection Switching ), MODE2(1 +1 Unidirecti onal Enumerati Protection on Type Switching ), MODE3(1 +1 Bidirectio nal Protection Switching ),

CHECK_ ON_INDE PENDEN T_PORT, CHECK_ Board Enumerati ON_PRIM Switchove on Type ARY_PO r RT, CHECK_ ON_STA NDBY_P ORT

MODE0

Alarm mode of feed tributary 0. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is SET fixed and Feed Tri. BTSDAT greater 0 Alarm BSC6900 UBP(Opti than the Mode onal) normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and

MRFD210304 MRFD210601

Faulty Managem MODE1( ent Mode1), Connectio Enumerati MODE2( n with on Type Mode2), TMA MODE3( (Tower Mode3) Mounted Amplifier)

MODE1

Alarm mode of feed tributary 1. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is SET fixed and Feed Tri. BTSDAT greater 1 Alarm BSC6900 UBP(Opti than the Mode onal) normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and

MRFD210304 MRFD210601

Faulty Managem MODE1( ent Mode1), Connectio Enumerati MODE2( n with on Type Mode2), TMA MODE3( (Tower Mode3) Mounted Amplifier)

MODE2

Alarm mode of feed tributary 2. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is SET fixed and Feed Tri. BTSDAT greater 2 Alarm BSC6900 UBP(Opti than the Mode onal) normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and

MRFD210304 MRFD210601

Faulty Managem MODE1( ent Mode1), Connectio Enumerati MODE2( n with on Type Mode2), TMA MODE3( (Tower Mode3) Mounted Amplifier)

MODE3

Alarm mode of feed tributary 3. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is SET fixed and Feed Tri. BTSDAT greater 3 Alarm BSC6900 UBP(Opti than the Mode onal) normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and

MRFD210304 MRFD210601

Faulty Managem MODE1( ent Mode1), Connectio Enumerati MODE2( n with on Type Mode2), TMA MODE3( (Tower Mode3) Mounted Amplifier)

MODE4

Alarm mode of feed tributary 4. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is SET fixed and Feed Tri. BTSDAT greater 4 Alarm BSC6900 UBP(Opti than the Mode onal) normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and

MRFD210304 MRFD210601

Faulty Managem MODE1( ent Mode1), Connectio Enumerati MODE2( n with on Type Mode2), TMA MODE3( (Tower Mode3) Mounted Amplifier)

MODE5

Alarm mode of feed tributary 5. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is SET fixed and Feed Tri. BTSDAT greater 5 Alarm BSC6900 UBP(Opti than the Mode onal) normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and

MRFD210304 MRFD210601

Faulty Managem MODE1( ent Mode1), Connectio Enumerati MODE2( n with on Type Mode2), TMA MODE3( (Tower Mode3) Mounted Amplifier)

MONITO Monitor RPERIOD Period

STR GBFDBTSRAC Monitorin 111202 BSC6900 KTEMPM g period GBFDON(Mand 111211 atory)

MONITO Monitor RTIME Time

STR GBFDBTSRAC Monitorin 111202 BSC6900 KTEMPM g duration GBFDON(Mand 111211 atory)

30MINS(3 O&M of 0 BTS Minutes), Reporting 60MINS(6 the 0 Enumerati Temperat Minutes), on Type ure List of 120MINS( the BTS 120 Equipmen Minutes), t Room 240MINS( 240 O&M of BTS Reporting the Interval Temperat 1~1440 Type ure List of the BTS Equipmen t Room

Month

Month

SET BTSAUT BSC6900 ODLDAC TINFO(M andatory)

Month when the TMU GBFDboard 111202 software is released A quick handover can be initiated only if the rate of an MS is higher than this parameter during a certain period of time. When the number of error frames on the MP group reaches the value of this parameter , the frame error alarm is generated When the number of error frames on the MP group decrease s to the value of this parameter , the frame error alarm is

O&M of BTS

Interval Type

0~12

Quick SET MOVESP Move GCELLH EEDTHR BSC6900 Speed OFAST(O ES Threshold ptional)

GBFD510102

Fast Interval Move Type Handover

0~600

ADD BTSMPG MP Group RP(Optio Frame MPGRPE nal) Error BSC6900 AAT IMP Alarm BTSMPG Threshold RP(Optio nal)

GBFD118611

Abis IP over E1/T1

Interval Type

0~100

ADD MP Group BTSMPG Frame RP(Optio MPGRPE Error nal) BSC6900 ADT Alarm IMP Clearance BTSMPG Threshold RP(Optio nal)

GBFD118611

Abis IP over E1/T1

Interval Type

0~100

ADD MPGRP( Mandator MP Group MP group MPGRPN BSC6900 y) No. number ADD MPLNK(M andatory)

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

0~167

ADD MP Group IPLOGIC MP group MPGRPN BSC6900 None No. PORT(Op number tional) Number of an MLPPP group on a BTS. It is unique in a BTS. The GBFDscope of 118611 the number of th MLPPP group in the BTS3900 series is 0~1. Timeslot

None

Interval Type

0~167

MLPPP MPGRPN Group No.

ADD BTSMPG RP(Mand atory) ADD BTSMPL NK(Mand atory) BSC6900 IMP BTSMPG RP(Mand atory) IMP BTSMPL NK(Mand atory)

Abis IP over E1/T1

Interval Type

0~3

multiplexi ng mode at the Abis interface of the BTS. The BTS supports two multiplexi ng modes: statistical multiplexi ADD Multiplexi GBFDng on a MPMODE BSC6900 BTS(Opti ng Mode 64 kbit/s 111301 onal) timeslot and physical multiplexi ng on a 16 kbit/s timeslot. The first mode is further classified into the following six types: 1:1, 2:1, 3:1, 4:1,

MODE1_ 1, MODE2_ 1, MODE3_ LAPD 1, Multiplexi Enumerati MODE4_ ng at Abis on Type 1, Interface MODE5_ 1, MODE6_ 1, MODE16 K

MPN

Connect Port No.

SET BTSFMU ABP(Opti onal) SET BTSAPM UBP(Opti onal) SET BTSDAT BSC6900 UBP(Opti onal) SET BTSDEM UBP(Opti onal) SET BTSDHE UBP(Opti onal)

MPSWIT MCPPP CH Switch

ADD BTSMPG RP(Optio Is Support GBFDnal) BSC6900 MCPPP. 118611 IMP BTSMPG RP(Optio nal) ADD BSC6900 MPGRP( MP type Optional) GBFD118611 GBFD118622

Number of the serial port where the board is located. The managem ent board refers to the TMU or RXU that directly communi cates with GBFDthe board. 111202 The configurat ion of this parameter must be consistent with the actual physical connectio n. Otherwise , the board may not work

O&M of BTS

Interval Type

0~1

Abis IP over E1/T1

DISABLE( Enumerati Disable), on Type ENABLE( Enable)

MPTYPE MP type

Abis IP over Enumerati MLPPP, E1/T1 on Type MCPPP A IP over E1/T1

SET MPUBIN D(Mandat MPUSLO MPU Slot BSC6900 ory) T No. ADD BRD(Man datory)

Number of the slot where the MRFDMPU 210301 subsyste m is located

Configura tion Interval Managem Type ent

0~27

Number of the subrack MPU MPUSUB where the Subrack RACK MPU No. subsyste m is located Whether power control algorithm II allows measure ment report compens ation. When making a power control decision, MR. SET the BSC MRCOMP Compens GCELLP retrieves BSC6900 REG ation WR2(Opti a certain Allowed onal) number of history measure ment reports and performs weighted filtering on the receive level values and receive quality SET MPUBIN D(Mandat BSC6900 ory) ADD BRD(Man datory)

MRFD210301

Configura tion Interval Managem Type ent

0~11

GBFD110703

Enhanced Power Enumerati NO(No), Control on Type YES(Yes) Algorithm

Allowed MRMISS MR COUNT Number Lost

If the number of measure ment reports lost consecuti vely is no larger than this value, linear interpolati on is performe SET d for the GCELLH values in BSC6900 OFITPEN the lost (Optional) measure ment reports based on the values in the two measure ment reports preceding and following the lost measure ment reports. When the

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~31

number of the lost measure ment reports SET exceeds MRMISS MRMissN GCELLP this GBFDBSC6900 NUM umber WR3(Opti parameter 117601 onal) during a power control period, the power control stops.

HUAWEI III Power Interval Control Type Algorithm

1~255

Frequenc y at which the BTSs submit Sent SET MRPREP preFreq.of GCELLH GBFDROCFRE BSC6900 processe preproces OCTRL(O 110802 Q d sed MR ptional) measure ment reports to the BSC

NOreport( Do not report), Twice_ps( Twice every second), PreOnce_ps( processin Once g of Enumerati every Measure on Type second), ment Once_2s( Report Once every two second), Once_4s( Once every four second)

SET MRRUAT Antenna BTSRXU TENFAC Tributary BSC6900 BP(Optio TOR1 1 Factor nal)

Attenuatio n factor for the GBFDTMA of 111202 antenna tributary 1 Attenuatio n factor for the GBFDTMA of 111202 antenna tributary 2

O&M of BTS

Interval Type

4~30

SET MRRUAT Antenna BTSRXU TENFAC Tributary BSC6900 BP(Optio TOR2 2 Factor nal)

O&M of BTS

Interval Type

4~30

MR SET MRSCOP Collection GMRSCO ESWITC BSC6900 Scope PE(Mand H Switch atory)

MR SET MRSWIT Collection GMRCTR BSC6900 CH Control L(Mandat Switch ory)

Switch of measure ment report collection within a specified scope. If the specified scope is a site, the switch applies to all the cells at the site; if the specified scope is a cell, the switch applies to the cell only. The switch of measure ment report collection within a specified scope last configure The control switch of measure ment report collection includes OFF (do not collect), ON_WIT H_SDCC H (collect measure ment reports for SDCCHs and TCHs), and ON_WIT HOUT_S DCCH (collect measure

GBFD111203

O&M of BSC

Enumerati OFF(Off), on Type ON(On)

GBFD111203

O&M of BSC

OFF(Off), ON_WIT H_SDCC H(On with Enumerati SDCCH), on Type ON_WIT HOUT_S DCCH(On without SDCCH)

MRU

Max Receive Unit

ADD BTSPPPL NK(Optio nal) ADD BTSMPL NK(Optio BSC6900 nal) IMP BTSPPPL NK(Optio nal) IMP BTSMPL NK(Optio

MS

Number of MSs

Maximum length of a received packet. The value of this parameter is negotiate d at both ends of a communi cation. Number of MSs used ADD when the BSC6900 AISSCFG offset (Optional) informatio n is collected Whether

GBFD118601

Abis over Interval IP Type

128~1500

GBFD118201

SoftSynchroni Interval zed Type Network

1~16

MSCAPA BLESTAT SWITCH

MSCCAP

to collect the informatio n about MS SET the MSs Capability GCELLS of BSC6900 Statistic OFT(Opti different Switch onal) capabilitie s in a cell. This parameter has no impact on Available capacity of the MSC. This parameter is valid MSC ADD only when Available GCNNOD the MSC Capability BSC6900 E(Optiona pool <K User l) function is number> enabled. It is set according to the actual capacity of the

GBFD110501

Call Control

Enumerati OFF(Off), on Type ON(On)

GBFD117401

MSC Pool

Interval Type

0~65535

ADD Length of GCNOPE MSCNRIL NRI in BSC6900 RATOR( EN TMSI Mandator y)

ADD MSC MSCNUL GCNOPE NULLBSC6900 LNRI RATOR( NRI Value Optional)

Number of bits occupied by the Network Resource Identifier in the TMSI. NRI specifies a CN node in the MSC Special NRI(Netw ork Resource Identifier) that is coded together with common NRIs. This parameter is used to indicate that the BSC routes the service initiated by the MS to the MSC in non OFFLOA

GBFD117401

MSC Pool

Interval Type

1~10

GBFD117401

MSC Pool

Interval Type

0~1023

Whether to enable the MSC pool function on the BSC6900. The MSC pool function enables up to 32 MSCs to provide services ADD for mobile MSC Pool MSCPOO GCNOPE subscribe GBFDFunction BSC6900 LALLOW RATOR( rs in a 117401 Enabled Optional) BSC6900. With the MSC pool function, one BSC6900 can be connecte d to multiple MSCs and the services in the BSC6900 are

MSC Pool

Enumerati NO(No), on Type YES(Yes)

Administr ative state of the MSC. This parameter is valid only when the MSC pool function is enabled. ADD MSC It is set MSCSTA GCNNOD GBFDAdministr BSC6900 according TUE E(Optiona 117401 able State to the l) actual operating state of the MSC. A call accesses the MSC only when this parameter is set to NORMAL.

OFFLOA D(Offload ), Enumerati NORMAL MSC Pool on Type (Normal), UNAVAIL (Unavaila ble)

Protocol version of the MSC that is connecte SET d to the MSC GCELLC BSC6900. GBFDMSCVER Version BSC6900 CUTRAN The 111804 Indication SYS(Opti supported onal) signaling varies with the protocol versions.

A Interface Protocol Process

R98_or_b elow(R98 Enumerati or below), on Type R99_or_a bove(R99 or above)

MSIPFAIL TREEST INDDELA ABLISH Y

SET GCELLT BSC6900 MR(Optio nal)

Call reestablis GBFDhment 110503 timer

Call Interval Reestabli Type shment

5000~400 00

MSISDN

MSISDN

CHK INNSPCH (Mandator y) STR CALLRES MSISDN BSC6900 LOP(Man value datory) ADD GCSCHR USER(Ma ndatory)

GBFD111203

O&M of BSC

String Type

None

MSISDNP MSISDN REFIX1 prefix 1

MSISDN prefix 1. When matching the call specified by the mobile number, the BSC6900 adds the MSISDN prefix 1 according SET to the BSCBASI value of BSC6900 C(Optiona this l) parameter . For example, when the value of this parameter is 123 and the mobile number to be matched is 456, the call matching

GBFD117701 GBFD117702

BSC Local Switch BTS Local Switch

String Type

None

MSISDNP MSISDN REFIX2 prefix 2

MSISDN prefix 2. When matching the call specified by the mobile number, the BSC6900 adds the MSISDN prefix 2 according SET to the BSCBASI value of BSC6900 C(Optiona this l) parameter . For example, when the value of this parameter is 123 and the mobile number to be matched is 456, the call matching

GBFD117701 GBFD117702

BSC Local Switch BTS Local Switch

String Type

None

MSISDNP MSISDN REFIX3 prefix 3

MSISDN prefix 3. When matching the call specified by the mobile number, the BSC6900 adds the MSISDN prefix 3 according SET to the BSCBASI value of BSC6900 C(Optiona this l) parameter . For example, when the value of this parameter is 123 and the mobile number to be matched is 456, the call matching

GBFD117701 GBFD117702

BSC Local Switch BTS Local Switch

String Type

None

MSISDNP MSISDN REFIX4 prefix 4

MSISDN prefix 4. When matching the call specified by the mobile number, the BSC6900 adds the MSISDN prefix 4 according SET to the BSCBASI value of BSC6900 C(Optiona this l) parameter . For example, when the value of this parameter is 123 and the mobile number to be matched is 456, the call matching

GBFD117701 GBFD117702

BSC Local Switch BTS Local Switch

String Type

None

MSISDNP MSISDN REFIX5 prefix 5

MSISDN prefix 5. When matching the call specified by the mobile number, the BSC6900 adds the MSISDN prefix 5 according SET to the BSCBASI value of BSC6900 C(Optiona this l) parameter . For example, when the value of this parameter is 123 and the mobile number to be matched is 456, the call matching

GBFD117701 GBFD117702

BSC Local Switch BTS Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117701 tBscLs1 for BSC 1 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BSC Local Switch

String Type

None

Prefix MsisdnPrf Number xList2Star for BSC tBscLs10 10

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same SET GBFDas the BSC6900 BSSLS(O value of 117701 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BSC Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117701 tBscLs2 for BSC 2 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BSC Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117701 tBscLs3 for BSC 3 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BSC Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117701 tBscLs4 for BSC 4 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BSC Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117701 tBscLs5 for BSC 5 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BSC Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117701 tBscLs6 for BSC 6 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BSC Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117701 tBscLs7 for BSC 7 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BSC Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117701 tBscLs8 for BSC 8 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BSC Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117701 tBscLs9 for BSC 9 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BSC Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117702 tBtsLs1 for BTS 1 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BTS Local Switch

String Type

None

Prefix MsisdnPrf Number xList2Star for BTS tBtsLs10 10

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same SET GBFDas the BSC6900 BSSLS(O value of 117702 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BTS Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117702 tBtsLs2 for BTS 2 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BTS Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117702 tBtsLs3 for BTS 3 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BTS Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117702 tBtsLs4 for BTS 4 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BTS Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117702 tBtsLs5 for BTS 5 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BTS Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117702 tBtsLs6 for BTS 6 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BTS Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117702 tBtsLs7 for BTS 7 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BTS Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117702 tBtsLs8 for BTS 8 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first

BTS Local Switch

String Type

None

If "Options for BSC Local Switch" is set to PREFIXN UMBER, and the first digits in the MSISDN of the called or calling are the same MsisdnPrf Prefix SET GBFDas the xList2Star Number BSC6900 BSSLS(O value of 117702 tBtsLs9 for BTS 9 ptional) this parameter , the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first If the first digits in the MSISDN of the called or calling are MsisdnSe Avoid SET the same GBFDgList2Avo Number BSC6900 BSSLS(O as the 117701 idBscLs1 for BSC 1 ptional) value of this parameter , the BSC local switching function is disabled.

BTS Local Switch

String Type

None

BSC Local Switch

String Type

None

If the first digits in the MSISDN of the called or calling are MsisdnSe Avoid SET the same gList2Avo Number BSC6900 BSSLS(O as the idBscLs1 for BSC ptional) value of 0 10 this parameter , the BSC local switching function is disabled. If the first digits in the MSISDN of the called or calling are MsisdnSe Avoid SET the same gList2Avo Number BSC6900 BSSLS(O as the idBscLs2 for BSC 2 ptional) value of this parameter , the BSC local switching function is disabled. If the first digits in the MSISDN of the called or calling are MsisdnSe Avoid SET the same gList2Avo Number BSC6900 BSSLS(O as the idBscLs3 for BSC 3 ptional) value of this parameter , the BSC local switching function is disabled.

GBFD117701

BSC Local Switch

String Type

None

GBFD117701

BSC Local Switch

String Type

None

GBFD117701

BSC Local Switch

String Type

None

If the first digits in the MSISDN of the called or calling are MsisdnSe Avoid SET the same gList2Avo Number BSC6900 BSSLS(O as the idBscLs4 for BSC 4 ptional) value of this parameter , the BSC local switching function is disabled. If the first digits in the MSISDN of the called or calling are MsisdnSe Avoid SET the same gList2Avo Number BSC6900 BSSLS(O as the idBscLs5 for BSC 5 ptional) value of this parameter , the BSC local switching function is disabled. If the first digits in the MSISDN of the called or calling are MsisdnSe Avoid SET the same gList2Avo Number BSC6900 BSSLS(O as the idBscLs6 for BSC 6 ptional) value of this parameter , the BSC local switching function is disabled.

GBFD117701

BSC Local Switch

String Type

None

GBFD117701

BSC Local Switch

String Type

None

GBFD117701

BSC Local Switch

String Type

None

If the first digits in the MSISDN of the called or calling are MsisdnSe Avoid SET the same gList2Avo Number BSC6900 BSSLS(O as the idBscLs7 for BSC 7 ptional) value of this parameter , the BSC local switching function is disabled. If the first digits in the MSISDN of the called or calling are MsisdnSe Avoid SET the same gList2Avo Number BSC6900 BSSLS(O as the idBscLs8 for BSC 8 ptional) value of this parameter , the BSC local switching function is disabled. If the first digits in the MSISDN of the called or calling are MsisdnSe Avoid SET the same gList2Avo Number BSC6900 BSSLS(O as the idBscLs9 for BSC 9 ptional) value of this parameter , the BSC local switching function is disabled.

GBFD117701

BSC Local Switch

String Type

None

GBFD117701

BSC Local Switch

String Type

None

GBFD117701

BSC Local Switch

String Type

None

MsisdnSe gList2Avo idBtsLs1

MsisdnSe gList2Avo idBtsLs10

MsisdnSe gList2Avo idBtsLs2

If the first digits in the MSISDN of the called or calling are Avoid SET the same Number BSC6900 BSSLS(O as the for BTS 1 ptional) value of this parameter , the BTS local switching function is disabled. If the first digits in the MSISDN of the called or calling are Avoid SET the same Number BSC6900 BSSLS(O as the for BTS ptional) value of 10 this parameter , the BTS local switching function is disabled. If the first digits in the MSISDN of the called or calling are Avoid SET the same Number BSC6900 BSSLS(O as the for BTS 2 ptional) value of this parameter , the BTS local switching function is disabled.

GBFD117702

BTS Local Switch

String Type

None

GBFD117702

BTS Local Switch

String Type

None

GBFD117702

BTS Local Switch

String Type

None

MsisdnSe gList2Avo idBtsLs3

MsisdnSe gList2Avo idBtsLs4

MsisdnSe gList2Avo idBtsLs5

If the first digits in the MSISDN of the called or calling are Avoid SET the same Number BSC6900 BSSLS(O as the for BTS 3 ptional) value of this parameter , the BTS local switching function is disabled. If the first digits in the MSISDN of the called or calling are Avoid SET the same Number BSC6900 BSSLS(O as the for BTS 4 ptional) value of this parameter , the BTS local switching function is disabled. If the first digits in the MSISDN of the called or calling are Avoid SET the same Number BSC6900 BSSLS(O as the for BTS 5 ptional) value of this parameter , the BTS local switching function is disabled.

GBFD117702

BTS Local Switch

String Type

None

GBFD117702

BTS Local Switch

String Type

None

GBFD117702

BTS Local Switch

String Type

None

MsisdnSe gList2Avo idBtsLs6

MsisdnSe gList2Avo idBtsLs7

MsisdnSe gList2Avo idBtsLs8

If the first digits in the MSISDN of the called or calling are Avoid SET the same Number BSC6900 BSSLS(O as the for BTS 6 ptional) value of this parameter , the BTS local switching function is disabled. If the first digits in the MSISDN of the called or calling are Avoid SET the same Number BSC6900 BSSLS(O as the for BTS 7 ptional) value of this parameter , the BTS local switching function is disabled. If the first digits in the MSISDN of the called or calling are Avoid SET the same Number BSC6900 BSSLS(O as the for BTS 8 ptional) value of this parameter , the BTS local switching function is disabled.

GBFD117702

BTS Local Switch

String Type

None

GBFD117702

BTS Local Switch

String Type

None

GBFD117702

BTS Local Switch

String Type

None

MsisdnSe gList2Avo idBtsLs9

MSLEVS TRQPBG T

If the first digits in the MSISDN of the called or calling are Avoid SET the same Number BSC6900 BSSLS(O as the for BTS 9 ptional) value of this parameter , the BTS local switching function is disabled. Whether to enable "Triggerin EN Quick g the PBGT HO SET quick ALG GCELLH BSC6900 PBGT When MS OFAST(O algorithm Leaves ptional) only when BTS an MS is far from the BTS"

GBFD117702

BTS Local Switch

String Type

None

GBFD510102

Fast Enumerati NO(No), Move on Type YES(Yes) Handover

MSMAXR MS MAX ETRAN Retrans

Maximum number of Channel Request message s that can be sent by an MS in an immediat e assignme nt procedure . SET After the GCELLC MS BSC6900 CBASIC( initiates Optional) the immediat e assignme nt procedure , it always listens to the message s on the BCCH and all the common control

GBFD111003 GBFD110301 GBFD110303 GBFD110502

Radio Common Channel Managem 1_Times( ent 1_Times), Location 2_Times( Updating Enumerati 2_Times), Paging on Type 4_Times( Assignme 4_Times), nt and 7_Times( Immediat 7_Times) e Assignme nt

Control command MSP SET of the Control MSPCMD MSP GBFDMSPCMD BSC6900 Comman (Mandator switchove 111701 d y) r protection group

CLEAR(C leared), LOP(Lock out of Protection ), FS(Forcib ly switchove r working link to protection link), Board Enumerati MS(Manu Switchove on Type al r switchove r from working link to protection link), EXERS(E xercisely switch working link to protection link) MCS1(M CS1), MCS2(M CS2), MCS3(M CS3), MCS4(M CS4), Enumerati MCS5(M on Type CS5), MCS6(M CS6), MCS7(M CS7), MCS8(M CS8), MCS9(M CS9)

SET MSRD MSRDMC GCELLP MCS BSC6900 SLEV SCHM(O Threshold ptional)

Threshold of the MS Receiver GBFDDiversity 510801 (MSRD) mode

MSRD

PDCH Downlink multiplex threshold in the Mobile Station Receiver Diversity (MSRD) mode. When this parameter is set to "80", the MSRD SET MS does MSRDPD PDCH GCELLP not adopt GBFDBSC6900 CHLEV Multiplex SCHM(O the 510801 Threshold ptional) MSRD mode. When the number of the TBF on the PDCH that is assigned to the MS exceeds this parameter or the coding rate of the

MSRD

Interval Type

10~80

MSRN

SET BTSFMU ABP(Opti onal) SET BTSAPM UBP(Opti onal) Subrack SET No. of BTSDAT BSC6900 Managem UBP(Opti ent Board onal) SET BTSDEM UBP(Opti onal) SET BTSDHE UBP(Opti onal)

Number of the subrack where the board is located. The managem ent board refers to the TMU or RXU that directly communi cates with the board. GBFDThe 111202 configurat ion of this parameter must be consistent with the actual physical connectio n. Otherwise , the board may not work properly.

O&M of BTS

Interval Type

0~254

Min DL ADD MSRXMI level on GEXT2G BSC6900 N candidate CELL(Opt Cell ional)

MS Rx SET MSRXQU Quality GCELLN ALSTATT BSC6900 Statistic C2PARA( HRSH Threshold Optional)

The M criteria supports setting minimum values for the downlink receive level of neighbori ng cells. The M criteria is met only when , Estimated downlink level of neighbori ng cells >= ("Min DL level on candidate Cell" + "Min Access Level Offset") Estimated uplink level of neighbori When the number of received measure ment reports on the downlink transmissi on quality (Packet Downlink Ack/Nack message) is greater than or equal to this threshold, emergenc y reselectio n decision

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

GBFD116201

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~255

MSTF

MS Flow Control Timer

Duration of the flow control timer F of the MS. SET The MS BSSGPP GBFDBSC6900 sends the ARA(Opti 119001 flow onal) control message according to this duration. If no handshak e message is received from the peer within the delay, the master service is activated. A master service object provides services at the local BSC and its configurat ion data is backed up at the peer BSC. A master service object provides services at the peer BSC Maximum TX power for the MS to access the PCH

Gb Interface Function

Interval Type

1000~300 0

Master MSTSER Service VACTDE Active LAY Delay

SET GBSCRE BSC6900 DGRP(Op tional)

GBFD113725

BSC Node Interval Redunda Type ncy

1~600

Maximum SET TX Power GCELLS MSTXPW for BSC6900 ERVPAR RMAX Access A(Optiona PCH l)

GBFD114101

GPRS

Interval Type

0~31

MSW

SelfSET healing SLFSLVS Switch for BSC6900 W(Option Memory al) Overload

SET MTCACC MTC BSCFCP ESSCPU Access BSC6900 ARA(Opti RATE CPU Rate onal)

Switch for the selfhealing of the OMU when the None OMU process memory is overloade Usage threshold of the CPU for called access. If the usage of the CPU GBFDexceeds 111705 the threshold, the called access request is transferre d to other CPU for processin

None

ON(ON), Enumerati OFF(OFF on Type )

GSM Flow Control

Interval Type

50~95

MTHD

Method

CHK E1T1CRS Detection BSC6900 None (Mandator method y)

None

ADD Identify MTP2 link MTP3LN GBFDBSC6900 an MTP2 No. K(Mandat 111804 link ory) Metric system. The ADD values of MTRLGY Metrology BSC6900 GPS(Opti this None onal) parameter include "MET" and MTP2LN KN ADD Maximum SCTPLN GBFDBSC6900 transport K(Optiona 118602 unit l)

A Interface Protocol Process

ALARM_ METHOD (Alarm Enumerati method), on Type LOOP_M ETHOD(L oop method) Interval Type 0~63

None

MET(Metr Enumerati ic), on Type IMP(Impe rial)

MTU

MTU value

A over IP

Interval Type

500~1500

MTU

SET GBFDMaximum MTU[Byte ETHPOR 118611 BSC6900 transmissi ] T(Optiona GBFDon unit l) 118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

256~1650

MTU

MTU

Maximum size of a packet SET that can BTSETH be GBFDBSC6900 PORT(Op transmitte 118611 tional) d or received on a FE port.

Abis IP over E1/T1

Interval Type

0~1500

MTVT

Bus Hierarchic voltage of al Power SET the GBFDSupply BSC6900 BTSBAT( battery 111202 Para.<0.1 Optional) rack of v> the BTS

O&M of BTS

Interval Type

190~240

MultiMULTIBA Band NDREP Report

Multiband point report value, including "report six cells with the strongest signal at each frequency point", "report SET one cell GCELLS GBFDwith the BSC6900 ERVPAR strongest 114101 A(Optiona signal at l) each frequency point","re port two cells with the strongest signal at each frequency point", and "report three cells with the

GPRS

REPORT 6(Report six), REPORT 1(Report Enumerati one), on Type REPORT 2(Report two), REPORT 3(Report three)

Period of performin g class-1 mute detection. If the bad frame rate reaches "Bad Frame Threshold of Mute Detection Class 1" within the MUTECH Period of SET period ECKCLA Mute GCELLS specified GBFDBSC6900 SS1PERI Detect OFT(Opti by this 111203 OD Class1 onal) parameter , mute speech may be detected. The setting of "Mute Detection Class 2 Switch" determine s whether to perform the class2 mute Whether the oneway audio problem is checked in class-2 SET detection. GCELLS In this GBFDBSC6900 OFT(Opti manner, 111203 onal) the oneway audio problems found in class-1 are checked to ensure

O&M of BSC

Interval Type

0~255

MUTECH ECKCLA SS2SWIT CH

Mute Detect Class2 Switch

O&M of BSC

DISABLE( DISABLE) Enumerati , on Type ENABLE( ENABLE)

Period of performin g the class-2 mute detection. After the BTS or TC initiates a class-2 mute detection request, the classPeriod of SET 2 mute MUTECH Mute GCELLS detection GBFDECKPEIR BSC6900 Detect OFT(Opti fails if 111203 OD Class2 onal) there is no response and no test TRAU frame is received by the end of the period specified by this parameter ; if the class-2 Time for prohibitin g the call from accessing the Access MUTEFO SET correspon Prohibited RBITCAL GCELLS ding GBFDUpon One- BSC6900 LTMINTV OFT(Opti channel 111203 Way AL onal) where Audio one-way audio is detected on the Abis interface.

O&M of BSC

Interval Type

0~10

O&M of BSC

Interval Type

0~15

Whether to forcibly Forced release a Call call after Release SET the forced Upon MUTERE GCELLS handover GBFDFailed BSC6900 LCALLEN OFT(Opti fails in the 111203 Handover onal) case of in Oneone-way Way audio on Audio the Abis interface

O&M of BSC

Enumerati NO(No), on Type YES(Yes)

Maximum PPP mux ADD time framing MUXTIME BSC6900 PPPLNK( waiting for outOptional) multiplexi time[us] ng

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

1~1500

Frame timeout PPP mux ADD duration framing MUXTIME BSC6900 MPGRP( of the None outOptional) PPP time[us] multiplexi ng group

None

Interval Type

1~1500

MUXTYP IP MUX E Type

GBFDADD IP packet 118604 BSC6900 IPMUX(M multiplexi GBFDandatory) ng type 118610

Abis MUX UDPMUX UDP , MUX for Enumerati ABISMUX A on Type , Transmis ATERMU sion X

Minimum number of Min SET reserved Quantity MWTRXN BTSCAB working GBFDof BSC6900 O PARA(Op status 111202 Working tional) TRXs of TRXs the cabinet GBFDMYDISCR My STR BFD local 118604 IMINATO discrimina BSC6900 IPCHK(O descriptio GBFDR tor of BFD ptional) n mark 118610

O&M of BTS

Interval Type

0~12

Abis MUX UDP MUX for Interval A Type Transmis sion

1~512

N200

N200

System parameter in the LAPD protocol. The value of this SET parameter BTSRING GBFDBSC6900 specifies ATTR(Opt 117801 the ional) maximum number of times when a frame is retransmit ted.

Ring Interval Topology Type

1~3

Error control is performe d on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in SET an I N200EST N200 of GCELLC frame, the GBFDBSC6900 AB Establish CTMR(Op BTS 111002 tional) should resend the I frame. This parameter indicates the maximum number of retransmi ssions of the I frame. For the function

Radio Link Interval Managem Type ent

5~254

Error control is performe d on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in SET an I N200 of N200FFU GCELLC frame, the GBFDFACCH/F BSC6900 LL CTMR(Op BTS 111002 ull Rate tional) should resend the I frame. This parameter indicates the maximum number of retransmi ssions of the I frame on the FACCH

Radio Link Interval Managem Type ent

34~254

Error control is performe d on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in SET an I N200 of N200FHA GCELLC frame, the GBFDFACCH/H BSC6900 LF CTMR(Op BTS 111002 alf Rate tional) should resend the I frame. This parameter indicates the maximum number of retransmi ssions of the I frame on the FACCH

Radio Link Interval Managem Type ent

29~254

N200PAR Use ASWITC LAPDm H N200

Whether the BSC6900 sends the LAPDm N200 parameter to the BTS. If this parameter is set to YES, the SET BSC GCELLC GBFDBSC6900 sends the CTMR(Op 111002 LAPDm tional) N200 parameter . If this parameter is set to NO, the BSC6900 does not send the LAPDm N200 parameter .

Radio Link Enumerati OFF(Off), Managem on Type ON(On) ent

N200 of N200REL Release

Error control is performe d on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in SET an I GCELLC frame, the GBFDBSC6900 CTMR(Op BTS 111002 tional) should resend the I frame. This parameter indicates the maximum number of retransmi ssions of the I frame during the multi-

Radio Link Interval Managem Type ent

5~254

N200SAC N200 of CH SACCH

Error control is performe d on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in SET an I GCELLC frame, the GBFDBSC6900 CTMR(Op BTS 111002 tional) should resend the I frame. This parameter indicates the maximum number of retransmi ssions of the I frame on the SACCH.

Radio Link Interval Managem Type ent

5~254

N200SDC N200 of CH SDCCH

Error control is performe d on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in SET an I GCELLC frame, the GBFDBSC6900 CTMR(Op BTS 111002 tional) should resend the I frame. This parameter indicates the maximum number of retransmi ssions of the I frame on the SDCCH.

Radio Link Interval Managem Type ent

23~254

N3101

SET GCELLST Maximum ANDARD Value of BSC6900 OPTPAR N3101 A(Optiona l)

Maximum value of the N3101 counter. In the dynamic uplink allocation mode, the network side enables multiple MSs to share the GBFDsame 114101 uplink channel through the USF value in the downlink data block. After the network side allocates the USF to the uplink TBF (the

GPRS

Interval Type

8~30

N3103

SET GCELLST Maximum ANDARD Value of BSC6900 OPTPAR N3103 A(Optiona l)

Maximum value of the N3101 counter. When the uplink transmissi on ends, if the network side receives the last RLC data block, the network GBFD114101 side sends an FAI=1 uplink packet acknowle dged/una cknowled ged message and starts N3103. If the packet control acknowle dgement

GPRS

Interval Type

2~5

N3105

SET GCELLST Maximum ANDARD Value of BSC6900 OPTPAR N3105 A(Optiona l)

Maximum value of the N3105 counter. After the downlink TBF is set up successfu lly, the N3105 is started on the network side. After the downlink RLC data block is added with the RRBP domain on the network side, the valid packet acknowle dged message responde d by the Counter

GBFD114101 GBFD119205

GPRS Dynamica lly Interval Adjusting Type the RRBP Frequenc y

3~10

N391

on the DTE side. After BC link integrity is verified according Paramete ADD GBFDto r of DTE BSC6900 BC(Optio "Paramet 510002 [N391] nal) er of DTE [N391]", the global state query request is originated on the

Gb Over FR

Interval Type

1~255

N392

Counter on the DTE side, recording the checking times "Paramet er of DTE [N393]". After BC link integrity is verified according to Paramete ADD "Paramet GBFDr of DTE BSC6900 BC(Optio er of DTE 510002 [N392] nal) [N392]", the BC link state is restored. That is: if the BC link state on the DTE side is failure, and the system is found normal in the

Gb Over FR

Interval Type

1~10

N393

Counter on the DTE side, recording the checking times "Paramet er of DTE [N393]". After BC link integrity is verified according to Paramete ADD "Paramet GBFDr of DTE BSC6900 BC(Optio er of DTE 510002 [N393] nal) [N392]", the BC link state is restored. That is: if the BC link state on the DTE side is failure, and the system is found normal in the

Gb Over FR

Interval Type

1~10

NACCSP Support T NACC

Whether to support the network assisted cell change (NACC). The NACC is used in the network control modes SET NC0, NC1 GCELLG or NC2. BSC6900 PRS(Opti The onal) NACC enables the network to notify the MS of the system informatio n of the neighbori ng cell when the MS is in the packet ADD Name of BSC6900 OPC(Man the OSP datory)

GBFD116301 GBFD119502

Network Assisted Cell Enumerati NO(No), Change on Type YES(Yes) (NACC) PS Handover

NAME

OSP name

GBFD111804

A Interface Protocol Process

String Type

None

NAME

DSP name

ADD Name of BSC6900 N7DPC(M the DSP andatory)

GBFD111804

A Interface Protocol Process

String Type

None

NAME

ADD Signalling Name of MTP3RT( GBFDRoute BSC6900 an MTP3 Mandator 111804 name route y)

A Interface Protocol Process

String Type

None

NAME

ADD Signalling MTP3LKS link set BSC6900 (Mandator name y)

Name of the GBFDsignalling 111804 link set

A Interface Protocol Process

String Type

None

NAME

ADD Name of Signalling MTP3LN GBFDBSC6900 the MTP3 link name K(Mandat 111804 link ory)

A Interface Protocol Process

String Type

None

NAME

Adjacent Node Name

ADD ADJNOD BSC6900 E(Mandat ory)

Name of the adjacent node

GBFD118605

IP QOS

String Type

None

NAME

Local entity name

Local entity name. ADD The local GBFDBSC6900 M3LE(Ma 118602 entity ndatory) name must be unique.

A over IP

String Type

None

NAME

Name of Destinatio ADD the GBFDn entity BSC6900 M3DE(Ma destinatio 118602 name ndatory) n entity The M3UA route names M3UA ADD GBFDand the route BSC6900 M3RT(Ma 118602 M3UA name ndatory) routes are in the oneto-one matching Name of the M3UA link set. M3UA The name ADD Signalling of the GBFDBSC6900 M3LKS(M link set M3UA 118602 andatory) name signalling link set must be unique.

A over IP

String Type

None

NAME

A over IP

String Type

None

NAME

A over IP

String Type

None

NAME

M3UA signaling link name. The M3UA link M3UA ADD names GBFDSignaling BSC6900 M3LNK(M and the 118602 link name andatory) M3UA links are in the oneto-one matching relation.

A over IP

String Type

None

NAME

PCU Name

ADD Name of BSC6900 PCU(Man the PCU datory) Whether to preferenti ally allocate loose multiplexi ng frequenci es to nonFilter consistent of the collision signal strength of power control. When sampling must be performe d (NAVGI) times before the MS obtains the efficient measure

GBFD114101

GPRS

String Type

None

Assign Non-AMR SET NAMRLF User GCELLC RMTRXA Loose BSC6900 HMGAD( LLOWED Fre. Optional) Reuse TRX

GBFD111005

Enhanced Channel Enumerati NO(No), Assignme on Type YES(Yes) nt Algorithm

NAVGI

SET GCELLP N_AVG_I BSC6900 SPWPAR A(Optiona l)

GBFD119115

Power Control

Interval Type

0~15

NBAMRT TFO FOSWIT Switch CH

SET GCELLB BSC6900 ASICPAR A(Optiona l)

ADD Neighbor NBR2GN GIBCAPN 2G Cell 1 BSC6900 CELL1ID CGRP(M Index andatory)

Whether to enable the Tandem Free Operation (TFO) function on the BTS through a CHANNE L ACTIVATI ON or MODE MODIFY message. This parameter specifies whether to enable the Tandem Free Operation (TFO) function. If the voice quality of an ongoing Uniform number of neighbori ng cell 1 index within a BSC6900, which uniquely identifies a cell and is in the range 0 to 5047.

GBFD115501 GBFD115502 GBFD115701 GBFD113301 GBFD113726

AMR FR AMR HR DISABLE( TFO Enumerati Disable), Enhanced on Type ENABLE( Full Rate Enable) TC Pool

MRFD210301

Configura tion Interval Managem Type ent

0~5047

ADD NBR2GN Neighbor GIBCAPN CELL1NA 2G Cell 1 BSC6900 CGRP(M ME Name andatory)

Name of neighbori GBFDng GSM 117002 cell 1

IBCA (Interfere nce String Based Type Channel Allocation )

None

Index of neighbori ng GSM cell 2. Uniform number of a cell ADD Neighbor index NBR2GN GIBCAPN MRFD2G Cell 2 BSC6900 within a CELL2ID CGRP(M 210301 Index BSC6900, andatory) which uniquely identifies a cell and is in the range 0 to 5047. ADD NBR2GN Neighbor GIBCAPN CELL2NA 2G Cell 2 BSC6900 CGRP(M ME Name andatory) Name of neighbori GBFDng GSM 117002 cell 2

Configura tion Interval Managem Type ent

0~5047

IBCA (Interfere nce String Based Type Channel Allocation )

None

Uniform number of a cell ADD index Neighbor NBR2GN G2GNCE within a MRFD2G Cell BSC6900 CELLID LL(Manda BSC6900 210301 Index tory) , which uniquely identifies a cell.

Configura tion Interval Managem Type ent

0~5047

ADD NBR2GN Neighbor G2GNCE Name of CELLNA 2G Cell BSC6900 LL(Manda a cell ME Name tory)

MRFD210301

Configura tion String Managem Type ent

None

Uniform number of a neighbori ng cell index within a BSC, ADD which NBR3GN Neighbor G3GNCE uniquely MRFDBSC6900 CELLID Cell Index LL(Manda identifies 210301 tory) a cell. The value range of the index of a 3G external cell is 5048 to 8047.

Configura tion Interval Managem Type ent

5048~804 7

ADD NBR3GN Neighbor G3GNCE CELLNA Cell BSC6900 LL(Manda ME Name tory)

Name of a MRFDneighbori 210301 ng cell

Configura tion String Managem Type ent

None

When this switch is on, it indicates that the data of the adjacent SET cell is Neighbor BTSAUT NBRCEL generated Cell Plan BSC6900 OPLANC LSWITCH automatic Switch FG(Optio ally. nal) When this switch is off, it indicates that these data must be configure ADD Neighbou G2GNCE BSC6900 r Cell CI LL(Manda tory)

GBFD510704 GBFD510601

PICO Automatic Enumerati OFF(OFF Configura on Type ), ON(ON) tion and Planning

NBRCI

Cell ID of a MRFDneighbori 210301 ng cell

Configura tion Interval Managem Type ent

0~65535

ADD Neighbou G2GNCE NBRLAC r Cell BSC6900 LL(Manda LAC tory)

Local Area Code MRFD(LAC) of a 210301 neighbori ng cell

Configura tion Interval Managem Type ent

1~65533, 65535

Mobile Country ADD Neighbou Code G2GNCE MRFDNBRMCC r Cell BSC6900 (MCC) of LL(Manda 210301 MCC a tory) neighbori ng cell ADD Neighbou G2GNCE NBRMNC r Cell BSC6900 LL(Manda MNC tory) Mobile Network Code (MNC) of a neighbori ng cell Whether the PCU of the cell supports the 64 neighbori ng cells. This parameter determine s the capability of reporting the number of the neighbori ng cells of the BSC in the NACC

Configura tion String Managem Type ent

None

MRFD210301

Configura tion String Managem Type ent

None

Support SET NBRSPT 64 GCELLG BSC6900 64 Neighbou PRS(Opti r Cells onal)

GBFD116201 GBFD116301

NetworkControlled Cell Reselecti on (NC2) Enumerati NO(No), Network on Type YES(Yes) Assisted Cell Change (NACC)

SET NC2 Load BSCPSS NC2Load Reselecti BSC6900 OFTPAR Resel on Switch A(Optiona l)

NC2SPT

Support NC2

SET GCELLG BSC6900 PRS(Opti onal)

Whether to involve the load of the target cell in the algorithm for NC2 cell reselectio n. If this parameter is set to Support, the load of the target cell is involved in the algorithm for NC2 cell reselectio Whether to support the network control 2 (NC2). The NC2 enables the network side to control the cell reselectio n for the MS when the MS reports the measure ment report of the local cell and the neighbori ng cell.When this parameter is set to "YES" and "Network

GBFD116201

NetworkNotSuppo Controlled rt(Not Enumerati Cell Support), on Type Reselecti Support(S on (NC2) upport)

GBFD116201 GBFD119502

NetworkControlled Cell Enumerati NO(No), Reselecti on Type YES(Yes) on (NC2) PS Handover

NCC

NCC

ADD GCELL(O ptional) BSC6900 ADD GEXT2G CELL(Ma ndatory)

NCC

NCC

ADD GCELLQ BSC6900 UICKSET UP(Optio nal)

Network color code that is provided by the telecom operator. The NCC is used to identify networks from area to area. The NCC is unique nationwid e. The BCC and the NCC form Network color code. It is used to uniquely identify different public land mobile network (PLMN) of the adjacent

MRFD210301

Configura tion Interval Managem Type ent

0~7

MRFD210301

Configura tion Interval Managem Type ent

0~7

SET NCCPER NCC GCELLID BSC6900 MIT Permitted LEBASIC( Optional)

SET GCELLE NCCPER NCC BSC6900 XTMSRP MITED Permitted ARA(Opti onal)

A set of NCCs of the cells to be measured by the MS. This parameter is an informatio n element (IE) in the system informatio n type 2 and 6 message s. If a bit of the value of this parameter is set to 1, the MS reports the correspon ding measure ment report to the BTS. The value of this NCC bitmap of the measure ment report sent by the MS. The MS reports only the NCC bitmap of the BSIC and the cell measure ment report that matches

GBFD110401 GBFD110402 GBFD111101

Basic Cell Selection Basic Cell ReBit Field selection Type System Informatio n Sending

SELECTI ON0_PE RM, SELECTI ON1_PE RM, SELECTI ON2_PE RM, SELECTI ON3_PE RM, SELECTI ON4_PE RM, SELECTI ON5_PE RM, SELECTI ON6_PE RM, SELECTI ON7_PE RM

GBFD110801 GBFD110802

Processin g of Measure ment Report Interval PreType processin g of Measure ment Report

0~255

For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in several Neighbor SET consecuti Cell Filter NCELLFI GCELLH ve GBFDLength BSC6900 LTER OFAST(O measure 510102 MR ptional) ment Number reports. This parameter indicates the number of measure ment reports used for the filtering of neighbori ng cell informatio

Fast Interval Move Type Handover

1~20

For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in several Filter SET consecuti NCELLFL Length for GCELLH ve BSC6900 TLEN Ncell OFITPEN measure RX_LEV (Optional) ment reports. This parameter indicates the number of measure ment reports used for the filtering of neighbori ng cell signal

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~31

Neighbori Neighbor SET ng cell NcellInter Cell OTHSOF interferen GBFDFLevelThr Interfere BSC6900 TPARA(O ce level 510901 es0 Level ptional) threshold Thresh 0 0

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

0~127

Neighbori Neighbor SET ng cell NcellInter Cell OTHSOF interferen GBFDFLevelThr Interfere BSC6900 TPARA(O ce level 510901 es1 Level ptional) threshold Thresh 1 1

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

0~127

Neighbori Neighbor SET ng cell NcellInter Cell OTHSOF interferen GBFDFLevelThr Interfere BSC6900 TPARA(O ce level 510901 es2 Level ptional) threshold Thresh 2 2

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

0~127

Neighbori Neighbor SET ng cell NcellInter Cell OTHSOF interferen GBFDFLevelThr Interfere BSC6900 TPARA(O ce level 510901 es3 Level ptional) threshold Thresh 3 3

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

0~127

Neighbori Neighbor SET ng cell NcellInter Cell OTHSOF interferen GBFDFLevelThr Interfere BSC6900 TPARA(O ce level 510901 es4 Level ptional) threshold Thresh 4 4

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

0~127

Neighbori Neighbor SET ng cell NcellInter Cell OTHSOF interferen GBFDFLevelThr Interfere BSC6900 TPARA(O ce level 510901 es5 Level ptional) threshold Thresh 5 5

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

0~127

Neighbori Neighbor SET ng cell NcellInter Cell OTHSOF interferen GBFDFLevelThr Interfere BSC6900 TPARA(O ce level 510901 es6 Level ptional) threshold Thresh 6 6

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

0~127

Neighbori Neighbor SET ng cell NcellInter Cell OTHSOF interferen GBFDFLevelThr Interfere BSC6900 TPARA(O ce level 510901 es7 Level ptional) threshold Thresh 7 7

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

0~127

NCH NCHOCB Occupy LOCKNU Block M Number

Number of blocks SET occupied GCELLG by the BSC6900 SMR(Opti NCH in onal) the group call service

GBFD510301 GBFD510302

Public Voice Group Call Interval Service Type Public Voice Broadcast Service

0~7

Number of the start block SET NCHSTA occupied NCH Start GCELLG RTBLOC BSC6900 by the Block SMR(Opti K NCH in onal) the group call service

GBFD510301 GBFD510302

Public Voice Group Call Interval Service Type Public Voice Broadcast Service

0~7

NCO

Network Control Mode

NEIGHB OR

Adjacent flag

Network control mode for cell reselectio n of the MS. There are three modes. NC0: normal MS control. The MS SET shall GCELLP perform BSC6900 SBASE(O autonomo ptional) us cell reselection. NC1: MS control with measure ment reports. The MS shall send measure ment reports to the network and the The DSP and OSP are in the ADD associate BSC6900 N7DPC(O d mode or ptional) non associate d mode.

GBFD119107 GBFD114302 GBFD119502 GBFD111101

Networkin g Control Mode GSM/TDNC0(NC0 SCDMA ), Interopera Enumerati NC1(NC1 bility on Type ), PS NC2(NC2 Handover ) System Informatio n Sending

GBFD111804

A Interface Protocol Process

NO(NO_ DIRECT_ CONNEC Enumerati T), on Type YES(DIR ECT_CO NNECT)

ADD NETMAS XPUVLA Net Mask BSC6900 K N(Mandat ory)

IP address MRFDmask of 210301 the VLAN

Configura IP tion Address Managem Type ent

None

Min NEWUR Interval GHOMINI for NTV Emerg. HO

Minimum interval between two consecuti ve emergenc y handover SET s GCELLH performe BSC6900 OCTRL(O d by an ptional) MS. During this interval, no emergenc y handover is allowed. ADD OMUIPR BSC6900 T(Mandat ory) IP address of the next hop

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~60

Forward NEXTHO Route P Address

None

None

IP Address Type

None

Forward NEXTHO route P address Forward NEXTHO route P address

ADD BSC6900 IPRT(Man Next hop None datory) ADD IPRTBIN BSC6900 D(Mandat ory) ADD BTSIPRT( Mandator y) ADD BSC6900 BTSIPRT BIND(Ma ndatory) IMP BTSIPRT( Mandator

None

IP Address Type IP Address Type

None

Next hop None

None

None

Forward NEXTHO Route P Address

IP address of the next hop

GBFD118611

Abis IP over E1/T1

IP Address Type

None

NI

Network ID

ADD Network BSC6900 OPC(Man ID datory)

GBFD111804

A Interface Protocol Process

INT(INT), INTB(INT B), Enumerati NAT(NAT on Type ), NATB(NA TB)

NM

Name of the file to be download DLD ed. The Download TCFILE( file name MRFDBSC6900 file name Mandator must be 210401 y) complete and does not contain a wildcard. This parameter is related to the paging channel of the system. There are three network operation modes: network operation SET mode I, Network GCELLP network Operation BSC6900 SBASE(O operation Mode ptional) mode II, and network operation mode III. Network operation mode I is used when the system is configure d with the Gs interface. Network

BSC/RNC Software String Managem Type ent

None

NMO

GBFD119108 GBFD114151

NMOI(Net work Operation Mode I), Network NMOII(Ne Operation Enumerati twork Mode on Type Operation Support Mode II), DTM NMOIII(N etwork Operation Mode III)

No Mains No Mains SET Supply Supply BTSALM GBFDNMSACN Alarm BSC6900 Alarm PORT(Ma 111202 Cabinet Cabinet ndatory) No. No.

O&M of BTS

Interval Type

0~255

No Mains SET No Mains Supply BTSALM Supply GBFDNMSAPN BSC6900 Alarm PORT(Ma Alarm 111202 Port No. ndatory) Port No.

O&M of BTS

Interval Type

0~255

No Mains SET No Mains Supply BTSALM Supply GBFDNMSASN BSC6900 Alarm PORT(Ma Alarm 111202 Slot No. ndatory) Slot No.

O&M of BTS

Interval Type

0~255

No Mains No Mains SET Supply Supply NMSASR BTSALM GBFDAlarm BSC6900 Alarm N PORT(Ma 111202 Subrack Subrack ndatory) No. No.

O&M of BTS

Interval Type

0~255

Lower SET Lower NO1M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.1 input A(Optiona input 210304 DOWN -48V[-V] l) voltage 1

Faulty Interval Managem Type ent

40~45

Upper SET Upper NO1M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.1 input A(Optiona input 210304 UP -48V[-V] l) voltage 1

Faulty Interval Managem Type ent

55~59

Lower SET Lower NO2M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.2 input A(Optiona input 210304 DOWN -48V[-V] l) voltage 2

Faulty Interval Managem Type ent

40~45

Upper SET Upper NO2M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.2 input A(Optiona input 210304 UP -48V[-V] l) voltage 2

Faulty Interval Managem Type ent

55~59

Lower SET Lower NO3M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.3 input A(Optiona input 210304 DOWN -48V[-V] l) voltage 3

Faulty Interval Managem Type ent

40~45

Upper SET Upper NO3M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.3 input A(Optiona input 210304 UP -48V[-V] l) voltage 3

Faulty Interval Managem Type ent

55~59

Lower SET Lower NO4M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.4 input A(Optiona input 210304 DOWN -48V[-V] l) voltage 4

Faulty Interval Managem Type ent

40~45

Upper SET Upper NO4M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.4 input A(Optiona input 210304 UP -48V[-V] l) voltage 4

Faulty Interval Managem Type ent

55~59

Lower SET Lower NO5M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.5 input A(Optiona input 210304 DOWN -48V[-V] l) voltage 5

Faulty Interval Managem Type ent

40~45

Upper SET Upper NO5M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.5 input A(Optiona input 210304 UP -48V[-V] l) voltage 5

Faulty Interval Managem Type ent

55~59

Lower SET Lower NO6M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.6 input A(Optiona input 210304 DOWN -48V[-V] l) voltage 6

Faulty Interval Managem Type ent

40~45

Upper SET Upper NO6M48 limit of PWRPAR limit of MRFDALMTHD BSC6900 No.6 input A(Optiona input 210304 UP -48V[-V] l) voltage 6

Faulty Interval Managem Type ent

55~59

Whether NOAMRF SET Non-AMR to allow ULLTOH GCELLH GBFDF-H Ho BSC6900 non-AMR ALFHOAL OBASIC( 510501 Allowed voice F-H LOW Optional) handover

HUAWEI Enumerati NO(No), II on Type YES(Yes) Handover

Decides the offset of the current ATCB together with other two parameter s: "F-H Ho Period" and period of triggering NOAMRF Non-AMR SET a F-H ULLTOH F-H Ho GCELLH handover, GBFDALFHOA ATCB BSC6900 OBASIC( thus 510501 TCBADJS Adjust Optional) selecting TEP Step target users for F-H handover s. ATCB offset = (Period of triggering a F-H handover / "F-H Ho Period" + 1) * "NonAMR F-H Ho ATCB

HUAWEI Interval II Type Handover

0~255

NOAMRF ULLTOH ALFHOA TCBTHR ESH

When the ATCB value of non-AMR full rate voice is Non-AMR SET no F-H Ho GCELLH smaller GBFDBSC6900 ATCB OBASIC( than this 510501 Threshold Optional) parameter , the condition for nonAMR F-H handover s is met.

HUAWEI Interval II Type Handover

0~255

Decides the current path cost offset together with other two parameter s: "F-H Ho Period" and period of triggering NOAMRF Non-AMR SET a F-H ULLTOH F-H Ho GCELLH handover, GBFDALFHOP Pathloss BSC6900 OBASIC( thus 510501 ATHADJS Adjust Optional) selecting TEP Step target users for F-H handover s. Path cost offset = (Period of triggering a F-H handover / "F-H Ho Period" + 1) * "NonAMR F-H

HUAWEI Interval II Type Handover

0~255

NOAMRF ULLTOH ALFHOP ATHTHR ESH

When the path loss value of non-AMR full rate voice is Non-AMR SET no larger F-H Ho GCELLH GBFDBSC6900 than this Pathloss OBASIC( 510501 parameter Threshold Optional) , the condition for nonAMR F-H handover s is met.

HUAWEI Interval II Type Handover

0~255

NOAMRF ULLTOH ALFHOQ UALTHR ESH

Quality threshold for nonAMR F-H handover s. When the uplink receive quality and Non-AMR SET downlink F-H Ho GCELLH receive GBFDBSC6900 Qual. OBASIC( quality of 510501 Threshold Optional) a user are both smaller than this parameter , a F-H handover is triggered for the user.

HUAWEI Interval II Type Handover

0~7

When the load of a cell is no smaller NOAMRF Non-AMR SET than this ULLTOH F-H GCELLH threshold, GBFDBSC6900 ALFTHRE Traffic OBASIC( non-AMR 510501 SH Threshold Optional) F-H handover s are triggered in the cell.

HUAWEI Interval II Type Handover

0~100

When the ATCB value of non-AMR half rate NOAMRH voice is Non-AMR SET ALFTOFU no larger H-F Ho GCELLH GBFDLLHOAT BSC6900 than this ATCB OBASIC( 510501 CBTHRE threshold, Threshold Optional) SH the condition for nonAMR H-F handover s is met.

HUAWEI Interval II Type Handover

0~255

NOAMRH ALFTOFU LLHOPAT HTHRES H

When the path loss value of non-AMR half rate voice is Non-AMR SET no H-F Ho GCELLH smaller GBFDBSC6900 Pathloss OBASIC( than this 510501 Threshold Optional) threshold, the condition for nonAMR H-F handover s is met.

HUAWEI Interval II Type Handover

0~255

Whether to trigger non-AMR H-F NOAMRH Allow NonSET handover ALFTOFU AMR H-F GCELLH s GBFDLLHOQU BSC6900 QualityOBASIC( according 510501 ALALLO based HO Optional) to the W uplink and downlink receive quality

HUAWEI Enumerati NO(No), II on Type YES(Yes) Handover

Quality threshold for nonAMR H-F handover s. When the receive NOAMRH Non-AMR SET quality of ALFTOFU H-F Ho GCELLH a user is GBFDLLHOQU BSC6900 Qual. OBASIC( no 510501 ALTHRE Threshold Optional) smaller SH than this parameter , the user meets the condition for H-F handover s.

HUAWEI Interval II Type Handover

0~7

When the load of a cell is no larger NOAMRH Non-AMR SET than this ALFTOFU H-F GCELLH threshold, GBFDBSC6900 LLTHRES Traffic OBASIC( non-AMR 510501 H Threshold Optional) H-F handover s are triggered in the cell.

HUAWEI Interval II Type Handover

0~100

NODET

Adjacent Node Type

ADD ADJNOD BSC6900 E(Mandat ory)

Type of the adjacent node

GBFD116902 GBFD118605 GBFD113726

ABIS(Abis Interface), A(A Ater Interface), Compres BSC(Ater sion Interface Enumerati Transmis on BSC), on Type sion TC(Ater IP QOS Interface TC Pool on TC), IUR_G(IU R_G Interface)

Cons.No SET NODLMR Dl Mr.HO GCELLH HOALLO BSC6900 Allowed OEMG(O WLIMIT Limit ptional)

No Dl NODLMR Mr.HO HOEN Allowed

SET GCELLH BSC6900 OEMG(O ptional)

Decisions of nodownlink measure ment report handover s can be made only when the number of consecuti ve nodownlink measure ment reports in the current call is no Whether to enable the nodownlink measure ment report handover algorithm

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~64

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

No Dl NODLMR Mr.Ul HOQUAL Qual HO LIMIT Limit

SET GCELLH BSC6900 OEMG(O ptional)

SET NOMINAL Norminal BTSPMU CAPACIT Capacity{ BSC6900 BP(Optio Y AH} nal)

When a certain number of nodownlink measure ment reports are received consecuti vely and the uplink receive quality is no smaller than this parameter , nodownlink measure ment report emergenc y handover s are triggered. Nodownlink measure ment report Normal output capacity of the battery group in specific dischargin g conditions (such as discharge rate, temperatu re, and final voltage). Generally, the parameter is based on 10hour

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

GBFD111202

O&M of BTS

Interval Type

1~1000

Whether to enable the III power control Allow III SET algorithm NONAMR Power GCELLP for Non- GBFDCALLPCA Control BSC6900 WR3(Opti AMR 117601 LLOWED For Nononal) calls. If AMR enabled, power control is performe d on Non-

HUAWEI OFF(Not III Power Enumerati Allowed), Control on Type ON(Allow Algorithm ed)

SET GCELLN NONDRX Non-DRX BSC6900 WCTRLM PERIOD Period SRPARA( Optional)

Period when the GBFDcell is in 119107 the nonDRX state

NODRX( NODRX), 0.24sec(0 .24sec), 0.48sec(0 .48sec), 0.72sec(0 Networkin Enumerati .72sec), g Control on Type 0.96sec(0 Mode .96sec), 1.20sec(1 .20sec), 1.44sec(1 .44sec), 1.92sec(1 .92sec)

When the ANT_A tributary antenna current abnormall y check mode is set to Mode 3, the parameter ALD Current Prompt A ALD SET Alarm is Cur-Minor NormalCu BTSRXU checked Alarm N- BSC6900 rDurA BP(Optio by Cur nal) periodical Duration pulse. The periodical pulse consists of antenna overcurrent duration and normal current duration. This

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

100~1000 0

B ALD SET Cur-Minor NormalCu BTSRXU Alarm N- BSC6900 rDurB BP(Optio Cur nal) Duration

Cell SET NORMAL Normal GCELLN RESELAL Reselecti BSC6900 C2PARA( LOW on Optional) Allowed

When the ANT_B tributary antenna current abnormall y check mode is set to Mode 3, the parameter ALD Current Prompt Alarm is checked by periodical pulse. The periodical pulse consists of antenna overcurrent duration and normal current duration. This Whether to allow the cell normal reselectio n. If this parameter is set to PERMIT and "NC2 Load Reselecti on Switch" is set to Support, the load of the target cell is involved in the algorithm for NC2 cell

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

100~1000 0

GBFD116201

NetworkFORBID( Controlled Enumerati Forbid), Cell on Type PERMIT( Reselecti Permit) on (NC2)

Normal work Normal SET temperatu Work BTSCAB GBFDNORTHD BSC6900 re TEMP PARA(Op 111202 threshold Threshold tional) of the cabinet Whether to discard paging message s without TMSIs and allcell paging message s that considera bly increase the load on the Maximum number of measure ment periods in which there is no traffic. If the number of measure ment periods in which there is no traffic reaches this parameter , the BTS reports an alarm indicating that there is no

O&M of BTS

Interval Type

400~700

NOTMSIA LLCELLP AGINGLI MITFLAG

Discard TMSI All Cell Paging

SET OTHSOF BSC6900 TPARA(O ptional)

GBFD111705

GSM Flow Control

CLOSE(C Enumerati lose), on Type OPEN(Op en)

SET Statistical NOTRAS GTRXRL Period of BSC6900 P ALM(Opti No-traffic onal)

GBFD111004

Radio Dedicated Interval Channel Type Managem ent

1~255

SET NOVGCS No VGCS BTSFALL BSC6900 TIME Call Time BACK(Op tional)

Number of TRC NQUERIE TRACER BSC6900 IPADDR( S T Optional) Packages Per TTL

If the BTS works in fallback mode and uplink VGCS connectio n is idle for a period specified by this parameter , the BTS disables GBFDthe VGCS 510309 connectio n automatic ally. This parameter is valid only for useroriginated VGCS calls and is invalid for fixed VGCS Number of TRACER None T packets sent to each TTL

Group Call Interval Reliability Type Enhancin g

10~255

None

Interval Type

1~10

For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in Filter several Length for SET consecuti NRBSDC SDCCH GCELLH ve GBFDCHFFLE BSC6900 NBR_RC OFITPEN measure 117501 N VD_BLO (Optional) ment CK reports. This parameter indicates the number of enhanced measure ment reports received on a signaling channel used to

Enhanced Measure Interval ment Type Report(E MR)

0~31

For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in Filter several Length for SET consecuti NRBTCH TCH GCELLH ve GBFDBSC6900 FFLEN NBR_RC OFITPEN measure 117501 VD_BLO (Optional) ment CK reports. This parameter indicates the number of enhanced measure ment reports received on a service channel used to Network resource indication ADD that NRIMSC NRI Value BSC6900 specifies MAP(Man a CN datory) node in the MSC pool Identifies the mapping relation ADD from the NRISGSN NRI Value BSC6900 NRI to the MAP(Man SGSN datory) uniquely with the operator name GBFD117401 GBFD119701

Enhanced Measure Interval ment Type Report(E MR)

0~31

NRI

MSC Pool Interval SGSN Type Pool

0~1023

NRI

GBFD119701

SGSN Pool

Interval Type

0~1023

Controls the values of the FDD_Indi c0 field, the NR_OF_F DD_CELL S field, and the FDD_Celli nformatio n field in 2quater and MI Support SET when 3G NRofFDD NR_of_F OTHSOF neighbori GBFDBSC6900 CellFlag DD_cells TPARA(O ng cells 111101 Writing ptional) with scramblin g code 0 are present. When this parameter is set to YES, FDD_Indi c0 is set to 1, the NR_OF_F DD_CELL S count does not ADD NSE(Man datory) ADD NSVC(Ma ndatory) ADD NSVLLO CAL(Man datory) Identifies NSE GBFDNSEI BSC6900 ADD a unique Identifier 119001 NSVLRE NSE MOTE(Ma ndatory) ADD PTPBVC( Mandator y) BLK PTPBVC( Mandator

System Enumerati NO(No), Informatio on Type YES(Yes) n Sending

Gb Interface Function

Interval Type

0~65534

NSEI

NSE Identifier

The identifier of a ADD network GCELLQ service GBFDBSC6900 UICKSET entity 119001 UP(Optio (NSE).An nal) NSE manages a group of NSVCs. For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in several consecuti ve measure ment reports. This parameter indicates the number of measure ment reports received on signaling channels used for the Whether the cell is located in the south latitude or north latitude

Gb Interface Function

Interval Type

0~65534

NCell SET Filter NSIGSTR GCELLH Length for BSC6900 FLTLEN OFITPEN SDCCH (Optional) Level

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~31

NSLATI

NS Latitude

SET GCELLLC BSC6900 S(Optiona l)

GBFD115402 GBFD118201

BSSNorth_latit Based ude(North LCS (Cell ID + TA) Enumerati latitude), on Type South_lati Softtude(Sout Synchroni h latitude) zed Network

NSVCI

NSVC Identifier

NSVC ID, identifies a unique NSVC. ADD This ID GBFDBSC6900 NSVC(Ma must be 510002 ndatory) negotiate d with the peer SGSN. ADD NSVC(Ma ndatory) BSC6900 BLK NSVC(Ma ndatory)

Gb Over FR

Interval Type

0~65534

NSVC index, NSVC NSVCIDX identifies Index a unique NSVC. If the inlet temperatu re is between "High Temperat ure Critical Point" and "Low Temperat ure Critical Point" and the Normal SET difference Temperat BTSDHE between NTDI BSC6900 ure Delta UBP(Opti the inlet Tin onal) temperatu re and the ambient temperatu re reaches the value of this parameter , the temperatu re control system controls the difference

GBFD510002

Gb Over FR

Interval Type

0~1023

GBFD111202

O&M of BTS

Interval Type

0~30

NTDO

Normal SET Temperat BTSDHE BSC6900 ure Delta UBP(Opti Tout onal)

NY2

Ny2

SET GCELLG BSC6900 SMR(Opti onal)

OAM flow SET OAMFLO min ETHPOR BSC6900 WBW bandwidth T(Optiona [%] l)

If the outlet temperatu re is between "High Temperat ure Critical Point" and "Low Temperat ure Critical Point" and the difference between the outlet temperatu re and the inlet temperatu re reaches the value of this parameter , the temperatu re control system controls the Number of retransmi ssions of the VGCS UPLINK GRANT message Ratio of the minimum guarantee bandwidth of the OAM stream to the port bandwidth

GBFD111202

O&M of BTS

Interval Type

0~30

GBFD510301

Public Voice Group Call Service

Interval Type

1~255

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

0~100

Minimum OAM flow guarantee ADD OAMFLO min bandwidth BSC6900 PPPLNK( WBW bandwidth of the Optional) [%] OAM stream

GBFD118611 GBFD118622 GBFD111202

Abis IP over E1/T1 Interval A IP over Type E1/T1 O&M of BTS

0~100

Minimum OAM flow guarantee ADD OAMFLO min bandwidth BSC6900 MPGRP( WBW bandwidth of the Optional) [%] OAM stream

GBFD118611 GBFD118622 GBFD111202

Abis IP over E1/T1 Interval A IP over Type E1/T1 O&M of BTS

0~100

Minimum OAM flow ADD guarantee OAMFLO min IPLOGIC bandwidth BSC6900 WBW bandwidth PORT(Op of the [%] tional) OAM stream Ratio of the minimum OAM flow guarantee ADD OAMFLO min bandwidth BSC6900 ETHTRK( WBW bandwidth of the Optional) [%] OAM stream to the port bandwidth

GBFD118605 GBFD111202

IP QOS O&M of BTS

Interval Type

0~100

GBFD111202 MRFD210103

O&M of BTS Interval Link Type aggregati on

0~100

DSCP value of the OAM stream. The data of the OAM stream are not SET added to OAMFLO DSCP of QUEUEM GBFDBSC6900 queues 0 WDSCP OAM flow AP(Mand 111202 to 5 for atory) transmissi on. Instead, the data of the OAM stream is added to the

O&M of BTS

Interval Type

0~63

Minimum OAM flow SET guarantee OAMMIN min QUEUEM bandwidth BSC6900 BWKEY bandwidth AP(Optio switch of switch nal) the OAM stream

GBFD111202 MRFD210103

O&M of BTS Enumerati OFF(OFF Link on Type ), ON(ON) aggregati on

OBJECTT Operate YPE Object

SET BTSANT Operation MRFDBSC6900 ANGLE(M object 210602 andatory)

SITE(SIT E), Remote Enumerati CELL(CE Electrical on Type LL), Tilt BOARD(B OARD)

OBJECTT Object YPE Type

STR TRXBUR Type of GBFDBSC6900 STTST(M the object 111207 andatory)

BYCELL( BTS Test Enumerati By CELL), Function on Type BYTRX(B y TRX)

OBJIDX

User Index

ADD GCSCHR Index of BSC6900 USER(Op object tional)

GBFD111203

O&M of BSC

Interval Type

0~499

OBJIDX

Object Index

This ADD parameter GPSCHR BSC6900 indicates None USER(Op the object tional) index.

None

Interval Type

0~499

OBJTP

Object Type

Shield type of the alarm. ADD "ALL" OBJALM MRFDBSC6900 indicates SHLD(Ma 210304 one shield ndatory) type instead of all types.

ALL(Shiel d by Alarm ID), BOARD(S Faulty hield by Enumerati Managem Board), on Type ent PORT(Shi eld by Port), DSP(Shie ld by BTS(BTS) , CELL(CE Faulty LL), Enumerati Managem LOC(LOC on Type ent ), BOARD(B OARD), PORT(PO CELL(Cell Configura ), tion Enumerati TRX(TRX Managem on Type ), ent CHN(Cha nnel)

OBJTP

Object Type

ADD BTSOBJA BSC6900 LMSHLD( Mandator y)

Type of the alarm MRFDshield 210304 object

Object index types SET Object used OBJTYPE BSC6900 FHO(Man Type when datory) command s are executed When the PDCHs are insufficien t, the streaming service with high priority can preempt the PDCHs that are seized by SET Preempt the OccupySt GCELLP Switch of streaming reamingS BSC6900 SOTHER Streaming service witch PARA(Op Resource with low tional) priority. After the PDCH resource preemptio n, the streaming service with low priority initiates the QoS negotiatio n with the SGSN. If

MRFD210301

GBFD119901

Streaming Enumerati OFF(OFF QoS(GBR on Type ), ON(ON) )

SET OLTOUL OL to UL GCELLH HOALLO HO BSC6900 OIUO(Opt W Allowed ional)

Whether to allow overlay-to- GBFDunderlay 113201 handover s

Concentri Enumerati NO(No), c Cell on Type YES(Yes)

This parameter specifies whether to configure the backup OML. When YES is configure d in the BTS, an OML is SET configure Configure OMLBKU BTSOML d in GBFDBackup BSC6900 P BACKUP( timeslot 113728 OML Optional) 31 of port 0 and port 1 respective ly. The links are establishe d on the two ports in turn after the BTS is reset. Once the OML is establishe

OML Backup

Enumerati NO(No), on Type YES(Yes)

If OML Detection Switch is set to OFF, then the OML timeslot automatic detection is not supported . In this case, the OML is carried on SET the OMLDET OML BTSOML GBFDdefault ECTSWIT Detection BSC6900 DETECT( timeslots. 111202 CH Switch Mandator If OML y) Detection Switch is set to ON, then the OML timeslot automatic detection is supported . In this case, you can run the "SET BTSOML

O&M of BTS

Enumerati OFF(OFF on Type ), ON(ON)

This parameter specifies the OML SET detecting OmlDetec Lapd Link OTHSOF GBFDBSC6900 time of tTime Detect TPARA(O 116601 AbisTime ptional) Bypass site OML when it is broken.

Abis Bypass

Interval Type

4~255

OMLDSC OML P DSCP

SET BSCABIS BSC6900 PRIMAP( Optional)

Differentia ted service GBFDcode of 111202 the specified The

O&M of BTS

Interval Type

0~63

summatio n of BTS SET average OML&ES OMLESL BTSBWP downGBFDL Average BSC6900 DL ARA(Man bandwidth 111202 Downdatory) of bandwidth OML&ES L link in BTS. The summatio n of BTS SET average OML&ES OMLESL BTSBWP upGBFDL Average BSC6900 UL ARA(Man bandwidth 111202 Updatory) of bandwidth OML&ES L link in BTS.

O&M of BTS

Interval Type

0~256

O&M of BTS

Interval Type

0~256

Service SET priority of OML BSCABIS OMLPRI BSC6900 the Priority PRIMAP( specified Optional) OML Priority of services on the OML. The operation and maintena nce link (OML) is used to transfer the OM SET OML informatio BSCSRV OMLSP Service BSC6900 n PRI(Optio PRI between nal) the BSC6900 and BTS. This parameter indicates the priority of services on the OML.0 is the SET Specified OMLVLA OML BSCABIS BSC6900 OML Vlan NID VlanId PRIMAP( Id Optional) Size of OML/ESL/ the EML SET OML/ESL/ LAPD BTSLAPD OMLWS BSC6900 EML Downlink WS(Optio Downlink Window nal) LAPD Size window External OMU ADD virtual IP External BSC6900 EMSIP(O address Network ptional) of the Virtual IP OMU

None

None

Interval Type

0~7

GBFD118605

IP QOS

Interval Type

0~7

GBFD111202

O&M of BTS

Interval Type

2~4094

GBFD118601

Abis over Interval IP Type

0~96

OMUIP

GBFD111202

O&M of BTS

IP Address Type

None

OMU OMUMAS External K Network Mask

Subnet mask of ADD the OMU GBFDBSC6900 EMSIP(O in the 111202 ptional) external network

O&M of BTS

IP Address Type

None

OP

OPC

OPC

OPCIDX

EXP LOG(Opti onal) ADD OP(Mand Account atory) Operator BSC6900 of the ULK operator USR(Man datory) ADD BTSOP(M andatory) Code of the original signaling point (OSP) in the ADD signaling GCELLO network. OSP BSC6900 SPMAP( In the Code Mandator signaling y) network, each signaling point is identified by a signaling point Code of the signaling point of the local office in the ADD signaling GCELLQ network. OSP BSC6900 UICKSET In the Code UP(Mand signaling atory) network, each signaling point has a correspon ding signaling Uniquely BLK identifies ACIC(Ma an OSP. OPC ndatory) BSC6900 see "ADD Index ADD OPC" AE1T1(M command andatory) .

GBFD111203 MRFD210305

O&M of BSC String Security Type Managem ent

None

MRFD210301 GBFD118701

Configura tion Managem Interval ent Type RAN Sharing

1~167772 15

GBFD111202

O&M of BTS

Interval Type

1~167772 15

GBFD111803

A Interface Interval Circuit Type Managem ent

0~4

ADD GCNOPE OperatorT Operator BSC6900 RATOR( ype Type Mandator y)

ADD GCNOPE Operator OPINDEX BSC6900 RATOR( Index Mandator y)

Primary operator or secondar y operator. Primary operator is an operator that provides equipmen t, whereas secondar y operator Index of the operator. This parameter uniquely identifies an operator.

GBFD118701

RAN Sharing

PRIM(Pri mary Enumerati Operator), on Type SEC(Sec ondary Operator)

GBFD118701

RAN Sharing

Interval Type

0~3

OP OPINDEX INDEX SET SET

Operator ADD index set GCBSAD GBFDBSC6900 to which DR(Mand 118701 the CBC atory) belongs In the normal mode, if the board cannot be reset, no operation is UPD performe JTGCPLD MRFDBSC6900 d. In the (Mandator 210401 force y) mode, if the board cannot be reset, the operation is performe d by

RAN Sharing

Bit Field Type

OPINDEX 0, OPINDEX 1, OPINDEX 2, OPINDEX 3

Operate OPMODE mode

BSC/RNC NORMAL Software Enumerati (Normal), Managem on Type FORCE(F ent orce)

It is one key filed of identifying A interface BLK CIC Operation GBFDOPMODE BSC6900 ACIC(Ma status Mode 111803 ndatory) and indicates the alignment mode of A interface circuit.

BYCICRA NGE(BY A CIC Interface Enumerati RANGE), Circuit on Type BYCICVA Managem LUE(BY ent CIC VALUE)

It is one key filed of identifying Ater interface BLK timeslot Operation ATERE1T status GBFDOPMODE BSC6900 Mode 1(Mandat and 111801 ory) indicates the alignment mode of Ater interface circuit.

BYTSRA Ater NGE(BY Interface TS Enumerati 4:1 RANGE), on Type Multiplexi BYTSVAL ng UE(BY TS VALUE)

It is one key filed of identifying A interface BLK timeslot Operation GBFDOPMODE BSC6900 AE1T1(M status Mode 111803 andatory) and indicates the alignment mode of A interface circuit.

BYTSRA A NGE(BY Interface TS Enumerati Circuit RANGE), on Type Managem BYTSVAL ent UE(BY TS VALUE)

It is one key filed of identifying Pb BLK Operation interface GBFDOPMODE BSC6900 PBCIC(M Mode CIC 111203 andatory) status and indicates the Pb interface

O&M of BSC

BYCICRA NGE(BY CIC Enumerati RANGE), on Type BYCICVA LUE(BY CIC VALUE)

ADD GCNNOD E(Mandat ory) ADD GCNOPE RATOR( Mandator y) ADD GCELL(O ptional) ADD GEXTSM LC(Mand atory) Operator ADD OPNAME BSC6900 Name GEXT2G CELL(Opt ional) ADD GEXT3G CELL(Opt ional) ADD NSE(Man datory) ADD SGSNNO DE(Mand atory) ADD NRISGSN MAP(Man

Name of the operator. This GBFDparameter 118701 uniquely identifies an operator

RAN Sharing

String Type

None

Channel assignme nt policies used when TCHs are assigned in an IUO cell: SysOpt: The system selects the preferenti SET allyAssign OPTILAY GCELLH assigned GBFDOptimum BSC6900 ER OIUO(Opt service 113201 Layer ional) layer and assigns channels according to the measure ment reports on SDCCHs; USubcell: preferenti ally assigns the TCHs on the underlay;

SysOpt(S ystem optimizati on), OSubcell( Overlaid Concentri Enumerati subcell), c Cell on Type USubcell( Underlaid subcell), NoPrefer( No preferenc e)

Preferenti ally assigns channels on the overlay when the uplink receive level on the SDCCH is no smaller than AssignSET "AssignOPTILEV optimumGCELLH optimum- GBFDBSC6900 THRES level OIUO(Opt level 113201 Threshold ional) Threshold " and the TA is smaller than "TA Threshold of Assignme nt Pref"; otherwise, assigns channels on the underlay to ensure successfu

Concentri Interval c Cell Type

0~63

Preferenti ally assigns channels on the overlay when the uplink receive level on the SDCCH is no smaller than TA SET "AssignThreshold OPTITAT GCELLH optimum- GBFDof BSC6900 HRES OIUO(Opt level 113201 Assignme ional) Threshold nt Pref " and the TA is smaller than "TA Threshold of Assignme nt Pref"; otherwise, assigns channels on the underlay to ensure successfu

Concentri Interval c Cell Type

0~255

OPTL

TRX Priority

This parameter specifies the TRX priority in channel assignme nt. The smaller this parameter is, the SET higher the GTRXDE TRX GBFDBSC6900 V(Optiona priority is. 111005 l) For two TRXs with other conditions identical, channels on the TRX with higher priority are preferenti ally

L0(Level0 ), L1(Level1 ), L2(Level2 ), Enhanced L3(Level3 Channel Enumerati ), Assignme on Type L4(Level4 nt ), Algorithm L5(Level5 ), L6(Level6 ), L7(Level7 )

OPTM

Optical interface standard

SET Optical BSC6900 OPT(Opti interface onal) standard

GBFD111202

O&M of BTS

Enumerati SDH, on Type SONET

OPTP

SWP Type of Operation BTSBRD( GBFDBSC6900 the Type Mandator 111202 operation y)

O&M of BTS

MANUAL( MANUAL) , FORCED( Enumerati FORCED) on Type , CLEARAL ARMA(CL EARALA

OPTYPE

Operate Type

The operation SET type can BTSFOR be GBFDBSC6900 BIDTS(M "FORBID" 111202 andatory) or "RESTOR E".

O&M of BTS

FORBID( Forbid), Enumerati RESTOR on Type E(Restore )

OPX

OPX

ADD GNRNC( BSC6900 Mandator y)

ADD Originally BTSTOP ORIPORT E1/T1 BSC6900 CONFIG( Port No. Mandator y)

Iur-g signaling point index of an internal RNC in GU mode If "Port Type" is set to "TOPEXT OUTPOR T", this parameter determine s the extended E1/T1 port through which the timeslots on the source E1/T1 port are used by other boards. If "Port Type" is set to "TOPEXT INPORT", this parameter

MRFD211402

MBSC Interval Load Type Balancing

0~4

MRFD211501

IP-Based 2G/3G CoTransmis Interval sion on Type Base Station Side

0~7

OT

CON PATCH(O Operation ptional) BSC6900 type LOD PATCH(O ptional)

Operation type of MRFDthe 210401 command .

Ordinary frequency . Multiple frequenci es are ADD separated Other GCELLQ by "&". OTHERF GBFDFrequenc BSC6900 UICKSET For REQ 110101 y UP(Optio example, nal) "22&33&4 4&55" are allocated to TRXs in ascending

One_touc h(execute on all BSC/RNC boards in Software Enumerati all Managem on Type subracks) ent , Step_by_ Step

Frequenc String y Band Type

None

Number SET OTHMOD of OtherBTSOTH BSC6900 NUM RAT PARA(Op Modules tional)

OtoU HO SET OTOURE Received GCELLH BSC6900 CEIVETH Level OIUO(Opt Threshold ional)

This parameter indicates the total number of hardware modules, excluding those of GSM. One of the parameter s that decide the underlay and overlay areas in an enhanced IUO cell. The underlay and overlay areas are decided by "OtoU HO Received Level Threshold ", "UtoO HO Received Level Threshold ",

GBFD114201

EGPRS

Interval Type

0~36

GBFD113201

Concentri Interval c Cell Type

0~63

UL SET Subcell GCELLH OUTASS Assignme BSC6900 OEDBPA OPTEN nt RA(Optio Optimizati nal) on

OUTBSC HOCLEA T8 RTIMER

SET GCELLT BSC6900 MR(Optio nal)

Whether to assign channel requests initiated in the underlay subcell to the overlay or underlay subcells according to "UL Subcell General Overload Threshold ". If the load of the underlay is higher than "UL Subcell General Overload Threshold ", incoming calls in the underlay subcell The timer is used to set the time when the BSC6900 waits for a handover success message after a handover command is sent in an outgoing BSC handover. If the timer expires, the outgoing BSC handover fails.

GBFD114402

Enhanced DualEnumerati NO(No), Band on Type YES(Yes) Network

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

500~6000 0

The timer is used to set the time when the BSC6900 waits for an HO REQ ACK message after a Handover SET OUTBSC Request GCELLT HOCMDT T7 BSC6900 message MR(Optio IMER is nal) reported in an outgoing BSC handover. If the timer expires, the outgoing BSC handover Whether to use external 2G Inter BSC SET neighbori OutBscLo Load GCELLH ng cells BSC6900 adHoEn Informatio OAD(Opti as the n Allowed onal) target cells of load handover s

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

500~6000 0

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

When the load of the underlay subcell is higher than this parameter , some of the calls in the underlay subcell will be UL SET switched OUTGEN Subcell GCELLH to the GBFDOVERLD General BSC6900 OEDBPA overlay 114402 THRED Overload RA(Optio subcell, Threshold nal) and channels in the overlay subcell will be preferenti ally assigned to calls initiated in the underlay subcell as well.

Enhanced DualInterval Band Type Network

0~100

OUTHOP WROVER LOADTH RESHOL D

Power SET Overload GTRXDE BSC6900 Threshold V(Optiona In Ho. Out l)

Outgoing SET OUTINNR OL GCELLH EXLEVTH Subcell BSC6900 OEDBPA RED HO Level RA(Optio TH nal)

Power overload threshold for triggering outgoing handover from the TRX under the prerequisi te that the power amplifier of the TRX GBFDprovides 111005 the maximum output power. If the power overload exceeds this threshold, the TRX triggers outgoing handover for lack of power. Lower threshold of the overlay level during overlay-tounderlay handover s. When the GBFDreceive 114402 level of an MS is higher than this threshold, the MS can be switched to the underlay

Enhanced Channel Interval Assignme Type nt Algorithm

0~50

Enhanced DualInterval Band Type Network

0~63

SET OUTLOA GCELLH Load HO DHOENA BSC6900 OEDBPA Allowed BLE RA(Optio nal)

Whether to allow overlay-toGBFDunderlay 114402 load handover s.

Enhanced DualEnumerati NO(No), Band on Type YES(Yes) Network

If the underlay load is higher than "UL Subcell Serious Overload Threshold ", the underlayMOD SET to-overlay OUTLOA Step LEN GCELLH handover GBFDDHOMOD of UL BSC6900 OEDBPA period 114402 PERI Load HO RA(Optio subtracts Period nal) a value that equals this threshold from "UL Subcell Load Hierarchic al HO Periods" every

Enhanced DualInterval Band Type Network

1~255

When the load of the underlay subcell exceeds "UL Subcell General Overload Threshold ", all the calls that are using UL this cell SET Subcell as the OUTLOA GCELLH Load GBFDserving DHOPERI BSC6900 OEDBPA Hierarchic 114402 cell OD RA(Optio al HO generate nal) Periods handover requests at the same time, which will suddenly increase the load of the BSC and possibly cause congestio n in the

Enhanced DualInterval Band Type Network

1~255

Level step during Step SET underlayOUTLOA Length of GCELLH to-overlay GBFDDHOSTE UL BSC6900 OEDBPA hierarchic 114402 P Subcell RA(Optio al load Load HO nal) handover s

Enhanced DualInterval Band Type Network

0~63

When the load of the underlay subcell is lower than this parameter , some of the calls in the overlay subcell will be UL SET switched OUTLOW Subcell GCELLH to the GBFDLOADTH Lower BSC6900 OEDBPA underlay 114402 RED Load RA(Optio subcell, Threshold nal) and channels in the underlay subcell will be preferenti ally assigned to channel requests initiated in the overlay

Enhanced DualInterval Band Type Network

0~100

OUTMAS Out BSC K Mask

Specifies ADD the SEMILIN GBFDBSC6900 timeslot K(Optiona 114701 mask out l) BSC6900

SemiPermane Bit Field nt Type Connectio n

TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

OUTPN

Out BSC Port No.

ADD SEMILIN BSC6900 K(Mandat ory) ADD DXXTSE BSC6900 XGRELA TION(Ma ndatory)

Outgoing BSC6900 GBFDport 114701 number Number of the GBFDoutgoing 111203 port of the DXX

SemiPermane Interval nt Type Connectio n

0~335

OUTPOR DXX Out TNO Port No.

O&M of BSC

Interval Type

0~15

ADD DXX Out DXXTSE OUTPOR Time Slot BSC6900 XGRELA TTS No. TION(Ma ndatory)

Number of the GBFDoutgoing 111203 timeslot of the DXX

O&M of BSC

Interval Type

0~31

Cannel 0 SET Digital OUTPUT BTSDTM Control BSC6900 0 UBP(Opti Signal onal) Level

Cannel 1 SET Digital OUTPUT BTSDTM Control BSC6900 1 UBP(Opti Signal onal) Level

Cannel 2 SET Digital OUTPUT BTSDTM Control BSC6900 2 UBP(Opti Signal onal) Level

Level of the accessed alarm signal. If the alarm signal has high level, this parameter should be set to 0. Otherwise , it should be set to 1. Level of the accessed alarm signal. If the alarm signal has high level, this parameter should be set to 0. Otherwise , it should be set to 1. Level of the accessed alarm signal. If the alarm signal has high level, this parameter should be set to 0. Otherwise , it should be set to 1.

GBFD111202

O&M of BTS

HIGH(Hig Enumerati h), on Type LOW(Low )

GBFD111202

O&M of BTS

HIGH(Hig Enumerati h), on Type LOW(Low )

GBFD111202

O&M of BTS

HIGH(Hig Enumerati h), on Type LOW(Low )

Level of the accessed alarm signal. If the alarm Cannel 3 SET signal has Digital OUTPUT BTSDTM high level, GBFDControl BSC6900 3 UBP(Opti this 111202 Signal onal) parameter Level should be set to 0. Otherwise , it should be set to 1. Output power of the location group. For a location group that consists of MRRU or GRRU boards, the default output ADD power is BTSLOC 15W. For GBFDBSC6900 GRP(Man a location 510104 datory) group that consists of DRRU boards, the default output power varies with frequency bands. That is, when the frequency band is Output ADD power of BTSLOC BSC6900 the GRP(Man location datory) group

O&M of BTS

HIGH(Hig Enumerati h), on Type LOW(Low )

OUTPUT Output POWER Power

Multi-site Interval Cell Type

10~2000

OUTPUT Output POWER1 Power

GBFD510104

Multi-site Interval Cell Type

300~530

OUTPUT Output POWERU Power NIT Unit

Output ADD power BTSLOC GBFDBSC6900 unit of the GRP(Opti 510104 location onal) group When the load of the underlay subcell is higher than this parameter , the underlayto-overlay load handover period subtracts a period GBFDthat 114402 equals "Step Length of UL Subcell Load HO" from "UL Subcell Load Hierarchic al HO Periods" every second, thus increasing the load Whether to report a cell out-ofservice GBFDalarm 111202 after a cell is out of service Outgoing BSC6900 GBFDslot 114701 number Slot number of the load GBFDoutlet 111203 interface board

0_1dB(0. Multi-site Enumerati 1dB), Cell on Type 0_1W(0.1 W)

UL SET OUTSERI Subcell GCELLH OVERLD Serious BSC6900 OEDBPA THRED Overload RA(Optio Threshold nal)

Enhanced DualInterval Band Type Network

0~100

Cell OutSET OUTSER of-Service GCELLS BSC6900 VICEALM Alarm OFT(Opti Switch onal)

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

OUTSN

Out BSC Slot No.

ADD SEMILIN BSC6900 K(Mandat ory) ADD ABISLOA BSC6900 DSHARE( Mandator y)

SemiPermane Interval nt Type Connectio n O&M of BSC Interval Type

0~27

OUTSN

Load Outlet Slot No.

0~27

Out BSC OUTSRN Subrack No.

ADD SEMILIN BSC6900 K(Mandat ory)

Allow SET Inter-RAT GCELLH OutSysLo Load HO BSC6900 OINTERR adHoEn in ATLDB(O Connect ptional) State

OUTSYS SET Service SERVHO OTHSOF Handover BSC6900 REASSIG TPARA(O Reassign NEN ptional)

Outgoing BSC6900 subrack number This parameter specifies whether to allow the interRAT load handover in connectio n mode (after the assignme nt is complete) When the Service Handover field in an ASS REQ message is 0, a direct retry process targeted at a 3G network is initiated. If the direct retry fails, the system decides whether to reassign channels for the current call based

GBFD114701

SemiPermane Interval nt Type Connectio n

0~11

GBFD114322

GSM/WC DMA Enumerati NO(No), Load on Type YES(Yes) Based Handover

GBFD114321

GSM/WC DMA Enumerati NO(No), Service on Type YES(Yes) Based Handover

Service SET OUTSYS Based OTHSOF SERVICE BSC6900 Handover TPARA(O HOEN Switch ptional)

Load Info ADD OUTTIME Timeout BSC6900 GNRNC( R Timer Optional)

Out BSC Start OUTTSN Timeslot No.

ADD SEMILIN BSC6900 K(Mandat ory)

When this parameter is set to Open, the BSS decides whether to hand over the current service to the 3G network according to the contents of the "Service Handover " informatio n element in the ASS REQ Validity period for the BSC to keep the load informatio n about a 3G neighbori ng cell on the RNC Outgoing BSC6900 start timeslot number

GBFD114321

GSM/WC CLOSE(C DMA Enumerati lose), Service on Type OPEN(Op Based en) Handover

MRFD211402

MBSC Interval Load Type Balancing

1~60

GBFD114701

SemiPermane Interval nt Type Connectio n

0~255

ANT_A SET ALD Over OverCurA BTSRXU Current BSC6900 lmThdA BP(Optio Occur nal) Threshold

ANT_B SET ALD Over OverCurA BTSRXU Current BSC6900 lmThdB BP(Optio Occur nal) Threshold

Abnormall y alarm raise threshold triggered by too heavy current of the ANT_A tributary antenna. When the actual current is higher than the configure d value, the ALD Current Abnormall y Alarm is triggered with the correspon ding alarm Abnormall y alarm raise threshold triggered by too heavy current of the ANT_B tributary antenna. When the actual current is higher than the configure d value, the ALD Current Abnormall y Alarm is triggered with the correspon ding alarm

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

Abnormall y alarm raise threshold triggered by too heavy current of the RET tributary antenna. When the RET ALD SET actual OverCurA Over BTSRXU current is MRFDlmThdRE Current BSC6900 BP(Optio higher 210304 T Occur nal) than the Threshold configure d value, the ALD Current Abnormall y Alarm is triggered with the correspon ding alarm tributary Clearance threshold for the alarm triggered when the ANT_A tributary ANT_A antenna SET ALD Over is over OverCurC BTSRXU Current BSC6900 current. lrThdA BP(Optio Clear When the nal) Threshold actual current is below this threshold, the ALD Current Abnormal Alarm is cleared.

Faulty Interval Managem Type ent

10~3500

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

Abnormall y alarm clearance threshold triggered by too heavy current of the ANT_B tributary antenna. When the ANT_B SET actual ALD Over OverCurC BTSRXU current is Current BSC6900 lrThdB BP(Optio lower Clear nal) than the Threshold configure d value, the ALD Current Abnormall y Alarm clearance is triggered with the correspon ding alarm

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

Clearance threshold for the alarm triggered when the RET tributary RET ALD antenna SET Over is over OverCurC BTSRXU MRFDCurrent BSC6900 current. lrThdRET BP(Optio 210304 Clear When the nal) Threshold actual current is below this threshold, the ALD Current Abnormall y Alarm is cleared.

Faulty Interval Managem Type ent

10~3500

When the ANT_A tributary antenna current abnormall y check mode is set to Mode 3, the parameter ALD Current Prompt A ALD SET Alarm is Cur-Minor OverCurD BTSRXU checked Alarm BSC6900 urA BP(Optio by Over-Cur nal) periodical Duration pulse. The periodical pulse consists of antenna overcurrent duration and normal current duration. This

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

100~1000 0

When the ANT_B tributary antenna current abnormall y check mode is set to Mode 3, the parameter ALD Current Prompt B ALD SET Alarm is Cur-Minor OverCurD BTSRXU checked Alarm BSC6900 urB BP(Optio by Over-Cur nal) periodical Duration pulse. The periodical pulse consists of antenna overcurrent duration and normal current duration. This

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

100~1000 0

Interval for the BTS transmitti ng overload message s to the BSC6900. This parameter is used to control the reporting SET frequency Overload OVERLO GCELLC of GBFDIndication BSC6900 ADINTV CCH(Opti overload 111003 Period onal) message s by the channel and TRX. The overload can be the TRX processor overload, downlink CCCH overload, or AGCH overload. For Temperat ure SET threshold Derating OVERTH BTSCAB of the GBFDTEMP BSC6900 D PARA(Op derating 111202 Threshold tional) function of the cabinet

Radio Common Interval Channel Type Managem ent

1~255

O&M of BTS

Interval Type

400~700

P11

CPU SET Usage for BSCFCP Critical BSC6900 ARA(Opti Paging onal) FC

P12

CPU SET Usage for BSCFCP Major BSC6900 ARA(Opti Paging onal) FC

P13

CPU SET Usage for BSCFCP Minor BSC6900 ARA(Opti Paging onal) FC

Threshold for critical flow control. When the usage of the CPU exceeds the threshold, the CPUS performs critical flow control for paging message Threshold for major flow control. When the usage of the CPU exceeds the threshold, the CPUS performs major flow control for paging message s. Threshold for minor flow control. When the usage of the CPU exceeds the threshold, the CPUS performs minor flow control for paging message s.

GBFD111705

GSM Flow Control

Interval Type

50~95

GBFD111705

GSM Flow Control

Interval Type

50~95

GBFD111705

GSM Flow Control

Interval Type

50~95

P14

Threshold for slight flow control. When the usage of CPU the CPU SET Usage for exceeds BSCFCP GBFDSlight BSC6900 the ARA(Opti 111705 Paging threshold, onal) FC the CPUS performs slight flow control for paging message s. This

GSM Flow Control

Interval Type

50~95

parameter specifies whether the multicarrier transceive r unit supports the MultiCarrier Intelligent Voltage Regulatio n feature. PA SET When this Intelligent BTSOTH parameter GBFDPaAdjVol BSC6900 Adjust PARA(Op is set to 111612 Voltage tional) YES, the multicarrier transceive r unit automatic ally regulates its working voltage according to the power requireme nts of a

MultiCarrier NO(NO), Intelligent Enumerati YES(YES Voltage on Type ) Regulatio n

Whether to support the function of moving the packet assignme nt down to the BTS. To improve the access speed of Move SET the MS, PACKAS Packet GCELLP after the GBFDSDLSHIF Assignme BSC6900 SOTHER 119202 packet T nt Down PARA(Op assignme to BTS tional) nt is moved down to the BTS, the BSC reserves the uplink resources for the BTS. The BTS obtains the channel request of

Packet NO(Not Assignme Enumerati Support), nt Taken on Type YES(Sup Over by port) the BTS

Average Average number of PAGINGA SET Paging paging VGCAPA GCELLS GBFDMessage BSC6900 message CITYINPE OFT(Opti 111705 Number s allowed RIOD onal) In Period in a cell in a period

GSM Flow Control

Interval Type

10~65535

BTS PAGINGL Paging IFETIME Lifetime

Lifetime of a paging message in the paging queue of the BTS. The setting of this parameter must be consistent with the SET setting of GCELLS timer GBFDBSC6900 OFT(Opti T3113 at 110303 onal) the core network; otherwise, the efficiency of paging schedulin g over the Um interface is reduced. It is recomme nded that this

Paging

Interval Type

0~255

Maximum MAX number of PAGING SET Paging paging MAXCAP GCELLS GBFDMessage BSC6900 message ACITYINP OFT(Opti 111705 Number s allowed ERIOD onal) In Period in a cell in a period

GSM Flow Control

Interval Type

10~65535

PAGTIME Paging S Times

For the BTS, this parameter is used to determine paging retransmi ssions. This parameter and the number of paging times configure SET d in the GCELLC MSC GBFDBSC6900 CBASIC( determine 110303 Optional) the number of paging retransmi ssions. The total number of paging times is approxim ately equal to the value of this parameter multiplied

Paging

Interval Type

1~8

This parameter sets the PAN_DE C value used by the counter N3102 of the MS. When the timer T3182 of the MS expires, SET the PAN_DE GCELLP N3102 GBFDPANDEC BSC6900 C SBASE(O reduces 114101 ptional) the value of PAN_DE C. 0: the value of PAN_DE C is 0; 7: the value of PAN_DE C is 7; Value N indicates that PAN_DE C is N;

GPRS

Pan_0(0), Pan_1(1), Pan_2(2), Pan_3(3), Enumerati Pan_4(4), on Type Pan_5(5), Pan_6(6), Pan_7(7), 255(not use)

This parameter sets the PAN_INC value used by the counter N3102 of the MS. When receiving the packet uplink SET acknowle GCELLP dged or PANINC PAN_INC BSC6900 SBASE(O unacknow ptional) ledged message sent by the network (V(S) or V(A) increases ), the MS increases the count (PAN_IN C) of the counter N3102. 0: the value RAN_MA X value, the maximum value of the N3102. 4: the value of SET PAN_MA PAN_MA GCELLP PANMAX BSC6900 X is 4; 32: X SBASE(O the value ptional) of PAN_MA X is 32. Value N indicates that PAN_DE C is N; Not use:

GBFD114101

GPRS

Pan_0(0), Pan_1(1), Pan_2(2), Pan_3(3), Enumerati Pan_4(4), on Type Pan_5(5), Pan_6(6), Pan_7(7), 255(not use)

GBFD114101

GPRS

Pan_4(4), Pan_8(8), Pan_12(1 2), Pan_16(1 6), Pan_20(2 Enumerati 0), on Type Pan_24(2 4), Pan_28(2 8), Pan_32(3 2), 255(not use)

Priority level at which the BSC shuts down the power amplifier of the TRX when the Priority of SET intelligent PAOPTIL Shut GTRXDE shutdown GBFDBSC6900 EVEL Down V(Optiona function is 111602 TRX l) enabled. If this parameter is set smaller, the priority level is higher, the power amplifier of the SET BTSAUT Patch No. BSC6900 ODLDAC TINFO(M andatory) Patch number of GBFDthe TMU 111202 board software

L0(Level0 ), L1(Level1 ), L2(Level2 ), TRX L3(Level3 Power Enumerati ), Amplifier on Type L4(Level4 Intelligent ), Shutdown L5(Level5 ), L6(Level6 ), L7(Level7 )

PatchNo

O&M of BTS

Interval Type

0~9999

PatchNo1

Patch Number

SET BTSAUT BSC6900 ODLDAC TINFO(M andatory)

Patch number of GBFDthe TMU 111202 board software

O&M of BTS

Interval Type

0~99

ADD PATHCH IP path IP path GBFDBSC6900 IPPATH( K check flag check flag 118605 Optional) GBFD118601 GBFDADD 118602 Uniquely IPPATH( GBFDIP path ID BSC6900 identifies Mandator 118605 an IP path y) GBFD118611 GBFD118622

IP QOS

ENABLE D(Enable Enumerati d), on Type DISABLE D(Disable

PATHID

Abis over IP A over IP IP QOS Interval Abis IP Type over E1/T1 A IP over E1/T1

0~65535

PATHID

ADD IPMUX(M andatory) IP path ID BSC6900 ADD IPPATHBI ND(Mand atory)

IP path ID,Identify None ing an IP path.

None

Interval Type

0~65535

Transmis sion loss Path Loss SET difference of GCELLP between PATHLO GBFDDifferent BSC6900 WRBASI radio SS 117602 Frequenc C(Optiona frequenci y Band l) es on different bands Whether to perform path lossSET based GCELLH GBFDBSC6900 sorting in OBASIC( 510501 a better Optional) cell handover algorithm

Active Power Control

Interval Type

0~255

Pathloss PATHLO Ho. SSHOEN Enable

HUAWEI Enumerati NO(No), II on Type YES(Yes) Handover

PATHT

IP path type

ADD Type of BSC6900 IPPATH( the IP Optional) path

GBFD118601 GBFD118602 GBFD118605 GBFD118611 GBFD118622

QoS(QoS ), BE(BE), AF11(AF1 1), AF12(AF1 2), AF13(AF1 3), AF21(AF2 Abis over 1), IP AF22(AF2 A over IP 2), IP QOS AF23(AF2 Enumerati Abis IP 3), on Type over AF31(AF3 E1/T1 1), A IP over AF32(AF3 E1/T1 2), AF33(AF3 3), AF41(AF4 1), AF42(AF4 2), AF43(AF4 3), EF(EF)

PATTYPE

Patch type

CON PATCH(O ptional) Patch BSC6900 LOD type PATCH(O ptional)

MRFD210401

PB

Pb

SET GCELLP BSC6900 SPWPAR A(Optiona l)

BTS power attenuatio GBFDn on the 119115 measured PBCCH

MAINCP U_PATC H(Main program me BSC/RNC patch), Software Enumerati DSP_PAT Managem on Type CH(DSP ent program me patch), UCODE_ PATCH(M arcrocode DB0(0dB) , DB2(2dB), DB4(4dB), DB6(6dB), DB8(8dB), DB10(10dB), DB12(12dB), Power Enumerati DB14(Control on Type 14dB), DB16(16dB), DB18(18dB), DB20(20dB), DB22(22dB), DB24(24dB), DB26(26dB), DB28(-

Whether to use the PBGT handover algorithm. PBGT handover s are based on path loss. The PBGT handover algorithm searches SET in real PBGTHO PBGT HO GCELLH time for GBFDBSC6900 EN Allowed OBASIC( cells that 110601 Optional) have lower path loss and meet certain system requireme nts, and decides whether to perform the handover s. To avoid pingpong

HUAWEI Enumerati NO(No), I on Type YES(Yes) Handover

PBGTLA ST

PBGT Valid Time

The triggering of PBGT handover s must meet the P/N criteria, that is, when the condition for PBGT ADD handover G2GNCE s is met GBFDBSC6900 LL(Option for a 110601 al) consecuti ve P seconds during N seconds, a PBGT handover is triggered. This parameter correspon ds to the

HUAWEI Interval I Type Handover

1~32

PBGT handover s to a neighbori ng cell are allowed only when the downlink level difference between the neighbori ADD ng cell PBGTMA PBGT HO G2GNCE and the GBFDBSC6900 RGIN Threshold LL(Option serving 110601 al) cell is larger than this parameter . When the value of this parameter is smaller than 64, handover s to a neighbori ng cell with a lower

HUAWEI Interval I Type Handover

0~127

PBGT PBGTST Watch AT Time

ADD G2GNCE BSC6900 LL(Option al)

MAX SET Retrans PbMtnMs OTHSOF Maintena BSC6900 gReSend TPARA(O nce Msg ptional) on Pb-I

The triggering of PBGT handover s must meet the P/N criteria, that is, when the condition for PBGT handover s is met for a consecuti ve P seconds during N seconds, a PBGT handover is triggered. This parameter correspon ds to the Maximum times for an external PCU to retransmit a PB interface maintena nce message. When the PCU fails to receive a response to a PB interface maintena nce message before the timer timeouts, it retransmit s the PB interface maintena nce message

GBFD110601

HUAWEI Interval I Type Handover

1~32

GBFD114101

GPRS

Interval Type

0~65535

PCADJP ERIOD

PC Interval

Minimum interval SET between GCELLP two GBFDBSC6900 WRBASI consecuti 110703 C(Optiona ve power l) control command s Channel used for the measured receiving power. It is used to set the measured receiving power level of the channel and control the power of the It is one key filed of identifying Pb interface CIC status and indicates the PCU No. correspon ding to the Pb interface PCU number, identifying a unique PCU. Port number of the E1/T1 of the Pb interface

Enhanced Power Interval Control Type Algorithm

1~15

SET GCELLP PCMEAS PC_MEA BSC6900 SPWPAR CHAN S_CHAN A(Optiona l)

GBFD119115

Power Control

BCCH(BC Enumerati CH), on Type PDCH(PD CH)

PCU

PCU No

BLK BSC6900 PBCIC(M andatory)

GBFD111203

O&M of BSC

Interval Type

0~31

PCUINDE PCU No. X

ADD BSC6900 PCU(Man datory) ADD PBE1T1( BSC6900 Mandator y)

GBFD114101

GPRS

Interval Type

0~31

PCUNO

PCU No.

GBFD111203

O&M of BSC

Interval Type

0~31

PCUNO

PCU No.

Number of the SET PCU to GCELLG GBFDBSC6900 which the PRS(Man 114101 current datory) cell belongs

GPRS

Interval Type

0~31

Whether the PCU supports the PREEMP T_ABIS_L INK message. If the BTS supports the FLEXABI S function, PCU the CS SET Support service PCUPRE BTSFLEX PREEMP can EMPTFLA BSC6900 ABISPAR T_ABIS_L preempt G A(Optiona INK the l) Message timeslots on the Abis interface used by the PS service. After the preemptio n occurs, the BSC6900 sends a PREEMP T_ABIS_L

GBFD111202 GBFD117301

O&M of NO(NO), Enumerati BTS YES(YES on Type Flex Abis )

PDCH downlink multiplex threshold, Indicating the maximum TBFs on the downlink PDCH (paramete r value/10). We PDCH SET recomma PDCHDW Downlink GCELLP nd that BSC6900 NLEV Multiplex SCHM(O the value Threshold ptional) of "Downlink Multiplex Threshold of Dynamic Channel Conversio n" should be less than "PDCH Downlink Multiplex Threshold " for

GBFD114101 GBFD113101 GBFD119303 GBFD119501 GBFD114101 GBFD113101 GBFD119303 GBFD119501

GPRS PDCH Dynamic Adjustme nt Load Sharing Adaptive Adjustme nt of Uplink and Downlink Channels Interval GPRS Type PDCH Dynamic Adjustme nt Load Sharing Adaptive Adjustme nt of Uplink and Downlink Channels

10~160

PDCH PDCHPW Power RSAVEN Saving Enable

This parameter specifies whether to enable the Power Optimizati on Based on Channel Type feature. The working voltage of SET the TRX GCELLS varies GBFDBSC6900 OFT(Opti with the 111606 onal) modulatio n mode of the channel. When this parameter is set to YES, the TRX adopts the working voltage according to the modulatio

Power Optimizati on Based Enumerati NO(No), on on Type YES(Yes) Channel Type

This parameter must be used together with "Level of Preemptin g Dynamic Channel" in the following conditions : SET 1. When PDCHRE PDCH GCELLP "Level of FORMIN Reformin BSC6900 SCHM(O Preemptin G g ptional) g Dynamic Channel" is set to "No preempt of service TCHF" and "PDCH Reformin g" is set to "Yes", the channels for the CS

GBFD113101 GBFD119303 GBFD119501

PDCH Dynamic Adjustme nt Load Sharing NO(NO), Enumerati Adaptive YES(YES on Type Adjustme ) nt of Uplink and Downlink Channels

PDCH uplink multiplex threshold, indicating the maximum TBFs on the uplink PDCH (paramete r value/10). We recomma PDCH SET nd that PDCHUP Uplink GCELLP the value BSC6900 LEV Multiplex SCHM(O of "Uplink Threshold ptional) Multiplex Threshold of Dynamic Channel Conversio n" should be less than "PDCH Uplink Multiplex Threshold " for triggering convertin Pending ADD PDTMRV PENDING timer of BSC6900 M3LKS(O ALUE timer the M3UA ptional) link set

GBFD114101 GBFD113101 GBFD119303 GBFD119501 GBFD114101 GBFD113101 GBFD119303 GBFD119501

GPRS PDCH Dynamic Adjustme nt Load Sharing Adaptive Adjustme nt of Uplink and Downlink Channels Interval GPRS Type PDCH Dynamic Adjustme nt Load Sharing Adaptive Adjustme nt of Uplink and Downlink Channels

10~70

GBFD118602 GBFD118622

A over IP Interval A IP over Type E1/T1

1~10

SET PeerBSCI Peer BSC GBSCRE BSC6900 D ID DGRP(M andatory)

Peer BSC ID. It GBFDidentifies 113725 a BSC.

BSC Node Interval Redunda Type ncy

0~65534

SET ID of the PEERBS Peer BSC GBFDBSC6900 BTSIP(Ma peer CID ID 118601 ndatory) BSC6900

Abis over Interval IP Type

0~65534

IP address of the SET PEERBS Peer BSC peer BSC6900 BTSIP(Ma CIP IP BSC6900 ndatory) on the homing BSC6900 Subnet SET PEERBS Peer BSC BSC6900 BTSIP(Ma CMASK Mask ndatory) mask of the port IP address at the peer BSC6900. Identifier of the peer BTS on the homing BSC6900 side Peer IP address of the PPP link. The IP address of the PPP link on the peer side of the

GBFD118601 GBFD113725

Abis over IP IP BSC Address Node Type Redunda ncy Abis over IP IP BSC Address Node Type Redunda ncy Abis over IP BSC Interval Node Type Redunda ncy

None

GBFD118601 GBFD113725

None

SET PEERBT Peer BTS BSC6900 BTSIP(Ma SID ID ndatory)

GBFD118601 GBFD113725

0~2047

PEERIP

Peer IP address

ADD PPPLNK( BSC6900 Mandator y)

GBFD118611 GBFD118622

Abis IP over IP E1/T1 Address A IP over Type E1/T1

None

PEERIP

Peer IP address

ADD MPGRP( BSC6900 Mandator y)

Peer IP address of the MP group.

GBFD118611 GBFD118622

Abis IP over IP E1/T1 Address A IP over Type E1/T1

None

PEERIP

Peer IP address

Detects STR the IP BSC6900 IPCHK(M address andatory) of the gateway

GBFD118609

IP Fault IP Detection Address Based on Type BFD

None

PEERIP

Peer IP Address

ADD BTSPPPL NK(Mand atory) BSC6900 IMP BTSPPPL NK(Mand atory)

IP address of the GBFDpeer end 118611 of BTS PPP Link.

Abis IP over E1/T1

IP Address Type

None

PEERIP

Peer IP Address

ADD BTSMPG RP(Mand atory) BSC6900 IMP BTSMPG RP(Mand atory)

IP address of the GBFDpeer end 118611 of BTS MLPPP Group.

Abis IP over E1/T1

IP Address Type

None

First destinatio First ADD n IP destinatio SCTPLN PEERIP1 BSC6900 address. n IP K(Mandat The address ory) invalid value is 0.

GBFD118602 GBFD118622

A over IP IP A IP over Address E1/T1 Type

None

Second destinatio Second ADD n IP destinatio SCTPLN PEERIP2 BSC6900 address. n IP K(Optiona The address l) invalid value is 0.

GBFD118602 GBFD118622

A over IP IP A IP over Address E1/T1 Type

None

PEERIPA Peer IP DDR address

The peer IP ADD address IPPATH( should GBFDBSC6900 Mandator not be the 118605 y) same as the local address.

IP QOS

IP Address Type

None

Peer PEERMA subnet SK mask

Subnet ADD mask of BSC6900 IPPATH( the peer Optional) IP

GBFD118601 GBFD118602 GBFD118605 GBFD118611 GBFD118622

Abis over IP A over IP IP QOS IP Abis IP Address over Type E1/T1 A IP over E1/T1

None

ADD Destinatio SCTPLN PEERPN n SCTP BSC6900 K(Mandat port No. ory)

Destinatio n SCTP port number

GBFD118602 GBFD118622

A over IP Interval A IP over Type E1/T1

1024~655 35

PEERVE Peer RSION Version

SET Peer BTSLOA BSC6900 Software DCTRL(M Version andatory) Whether to punish the target cell when a handover fails or to punish the current serving cell when a handover is of more SET TA or bad GCELLH quality. BSC6900 OCTRL(O After a ptional) handover fails due to congestio n of the target cell, the system needs to punish the target cell to prevent the MS from attemptin

GBFD111202

O&M of BTS

String Type

None

PENALTY Penalty EN Allowed

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

Cell PENALTY Penalty LASTTM Duration

Penalty duration for cell reselectio n. Cell penalty can be performe d only in this duration. When this parameter is set to a greater SET value, the GCELLN MS GBFDBSC6900 C2PARA( cannot 116201 Optional) reselect a cell for a longer time in the case of reselectio n failure or reselectio n due to load. The penalty timer is shorter when this

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~255

Cell PENALTY Penalty RXLEV Level

When the cell reselectio n failure message is received or the load cell reselectio n is initiated, the "Cell Penalty Level" is SET subtracte GCELLN d from the GBFDBSC6900 C2PARA( receive 116201 Optional) level of the target cell to avoid that cell reselectio n failure occurs repeatedl y or that multiple MSs are reselecte d to the same target

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~63

Timer of penalty on a neighbori SET ng cell PENALTY CfgPenalt GCELLH when a BSC6900 TIMER yTimer OFITPEN handover (Optional) fails due to faults of data configurat ion.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

PERIOD

Ping Check Period

Ping ADD check BSC6900 IPPATH( period of Optional) IP Path

GBFD118605

IP QOS

Interval Type

1~60

PERIOD

Measure ment Period

Measure ment STR period for GBFDBSC6900 NCS(Man each 510901 datory) frequency group

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

1~48

PFC

Compres sion flag Protocal ADD of the field BSC6900 PPPLNK( PPP link compress Optional) protocol domain

GBFD118611 GBFD118622

Abis IP Disable(D over Enumerati isable), E1/T1 on Type Enable(E A IP over nable) E1/T1

PFC

Compres sion flag Protocol ADD of the field BSC6900 MPGRP( PPP link compress Optional) protocol domain ADD BTSPPPL NK(Optio nal) ADD Support BTSMPG Protocol RP(Optio Field BSC6900 nal) Compres IMP s BTSPPPL NK(Optio nal) IMP BTSMPG RP(Optio

GBFD118611 GBFD118622

Abis IP Disable(D over Enumerati isable), E1/T1 on Type Enable(E A IP over nable) E1/T1

PFC

Whether to compress the GBFDprotocol 118611 field of the PPP link.

Abis IP over E1/T1

Enumerati NO(No), on Type YES(Yes)

PFC PFCSUP Support

Whether to support packet flow context (PFC). ADD The PFC GBFDBSC6900 NSE(Opti flow is 119901 onal) used to control the QoS of the packet service of the MS.

NO(No Streaming Enumerati Support), QoS(GBR on Type YES(Sup ) port)

Whether to support the paging message classificati on Paging SET PGCLAS function: Message BSCFCP GBFDSIFINGAL BSC6900 0,close; Classifyin ARA(Opti 111705 LOWED 1,paging g Allowed onal) message classificati on flow control; 2,repaging flow

GSM Flow Control

Interval Type

0~2

Maximum number of paging message s that the Max CS SET BSC6900 PGMAXM Paging BSCFCP can GBFDSGNUMI Message BSC6900 ARA(Opti process 111705 NPERIOD Num in onal) over the A Period interface within a measure ment period

GSM Flow Control

Interval Type

10~1000

Maximum number of PS paging Max PS message PGMAXP SET Paging s that the SMSGNU BSCFCP GBFDMessage BSC6900 BSC6900 MINPERI ARA(Opti 111705 Num in can OD onal) Period process within a "Paging Statistical Period".

GSM Flow Control

Interval Type

10~2000

Measure ment period for SET calculatin Paging PGSTAT BSCFCP g the GBFDStatistical BSC6900 PERIOD ARA(Opti arrival 111705 Period onal) rate of paging message s

GSM Flow Control

Interval Type

100~6000 00

PHB

Value of SET the perPer-Hop PHBMAP( BSC6900 hop Behavior Mandator behavior y) (PHB)

GBFD118605

IP QOS

BE(BE), AF11(AF1 1), AF12(AF1 2), AF13(AF1 3), AF21(AF2 1), AF22(AF2 2), AF23(AF2 Enumerati 3), on Type AF31(AF3 1), AF32(AF3 2), AF33(AF3 3), AF41(AF4 1), AF42(AF4 2), AF43(AF4 3), EF(EF)

PHB

PHB

PHB type ADD of the BSC6900 IPMUX(M IPMUX to andatory) be enabled

GBFD118604 GBFD118610

Abis MUX UDP MUX for Bit Field A Type Transmis sion

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF

PI

Cell Reselect Paramete rs Indication (PI), sent on the broadcast channel, indicates whether "Cell Cell SET Reselect Reselect GCELLID Offset", Paramete BSC6900 LEBASIC( "Cell rs Optional) Reselect Indication Temporar y Offset" in the "SET GCELLID LEAD" command , and "Cell Reselect Penalty Time" are used.

GBFD110402 GBFD111101

Basic Cell Reselection Enumerati NO(No), System on Type YES(Yes) Informatio n Sending

Whether to enable the private key password Private DISABLE: SET Key indicating PKPEnabl CERTFIL MRFDPassword BSC6900 that the eSta E(Optiona 210305 Enabled private l) State key password is disabled ENABLE: indicating that the

DISABLE( Security Enumerati Disabled), Managem on Type ENABLE( ent Enabled)

PKTCOU PKT NT Count

Indicates the number of STR the ETHOAM packets GBFDBSC6900 LOOPTS for remote 118630 T(Optiona loopback l) test of the OAM in the Ethernet Indicates

Ethernet OAM

Interval Type

5~64

PKTLEN

the length of the STR packets ETHOAM for the PKT GBFDBSC6900 LOOPTS remote Size[Byte] 118630 T(Optiona loopback l) test of the OAM in the Ethernet STR Loopback FRPORT BSC6900 packet None LOOP(Ma length ndatory)

Ethernet OAM

Interval Type

64~1024

PKTLEN

Packet Length

None

Interval Type

2~1500

Maximum multiplexi ng frame length. The length of the multiplexe d packet must not exceed the maximum multiplexi ng frame ADD length. If Maximum BTSABIS PKTLENT the length GBFDFrame BSC6900 MUXFLO HRES 118604 of the Length W(Option multiplexe al) d packet exceeds the maximum multiplexi ng frame length, the packet is transferre d without being added with new subframe

Abis MUX

Interval Type

24~1031

Whether the cell supports the PACKET SI STATUS flow. In the PACKET SI STATUS flow, the MS sends the SET Packet PACKET GCELLG PSI/SI GBFDPKTSI BSC6900 SI PRS(Opti Status 119801 onal) message to indicate that the MS has stored the system message. The network side sends the Packet Serving Cell Data message to notify Indicates the size of the PING PING packet, Size of PKTSIZE BSC6900 IP(Option neither IP None packet al) header nor ICMP header is included. PING MAC(Opti Sent onal) PKTSIZE PKT Size BSC6900 packet PING size BTSCFM( Optional)

Packet SI Enumerati NO(No), Status on Type YES(Yes)

None

Interval Type

20~1500

GBFD118630

Ethernet OAM

Interval Type

95~512

PL1

Persisten ce level 1 of the radio access priority. During MS access, the access priority of the MS is set. If the priority of SET the MS is Persisten GCELLP higher GBFDBSC6900 ce Level 1 RACH(Op than the 119110 tional) access priority of the MS, the cell allows the access of the MS. Otherwise , the cell rejects the access of the MS. The value "no use" indicates

Access

0_level(0 _level), 1_level(1 _level), 2_level(2 _level), 3_level(3 _level), 4_level(4 _level), 5_level(5 _level), 6_level(6 _level), 7_level(7 _level), Enumerati 8_level(8 on Type _level), 9_level(9 _level), 10_level( 10_level), 11_level( 11_level), 12_level( 12_level), 13_level( 13_level), 14_level( 14_level), 16_level( 16_level), nouse(no use)

PL16QA M

Power attenuatio n level of all the other timeslots of the BCCH except for timeslot 7 in 16QAM. The attenuatio 16QAM n level SET Transmitt ranges GTRXDE GBFDer Power BSC6900 from 0 to V(Optiona 114201 Reduce 50, with l) Level the step of 0.2 dB. When the EDGE TRX sends signals in 16QAM, the transmit power must be lower than the mean

EGPRS

Interval Type

0~50

PL2

Persisten ce level 2 of the radio access priority. During MS access, the access priority of the MS is set. If the priority of SET the MS is Persisten GCELLP higher GBFDBSC6900 ce Level 2 RACH(Op than the 119110 tional) access priority of the MS, the cell allows the access of the MS. Otherwise , the cell rejects the access of the MS. The value "no use" indicates

Access

0_level(0 _level), 1_level(1 _level), 2_level(2 _level), 3_level(3 _level), 4_level(4 _level), 5_level(5 _level), 6_level(6 _level), 7_level(7 _level), Enumerati 8_level(8 on Type _level), 9_level(9 _level), 10_level( 10_level), 11_level( 11_level), 12_level( 12_level), 13_level( 13_level), 14_level( 14_level), 16_level( 16_level), nouse(no use)

PL3

Persisten ce level 3 of the radio access priority. During MS access, the access priority of the MS is set. If the priority of SET the MS is Persisten GCELLP higher GBFDBSC6900 ce Level 3 RACH(Op than the 119110 tional) access priority of the MS, the cell allows the access of the MS. Otherwise , the cell rejects the access of the MS. The value "no use" indicates

Access

0_level(0 _level), 1_level(1 _level), 2_level(2 _level), 3_level(3 _level), 4_level(4 _level), 5_level(5 _level), 6_level(6 _level), 7_level(7 _level), Enumerati 8_level(8 on Type _level), 9_level(9 _level), 10_level( 10_level), 11_level( 11_level), 12_level( 12_level), 13_level( 13_level), 14_level( 14_level), 16_level( 16_level), nouse(no use)

PL32QA M

Power attenuatio n level of all the other timeslots of the BCCH except for timeslot 7 in 32QAM. The attenuatio 32QAM n level SET Transmitt ranges GTRXDE GBFDer Power BSC6900 from 0 to V(Optiona 114201 Reduce 50, with l) Level the step of 0.2 dB. When the EDGE TRX sends signals in 32QAM, the transmit power must be lower than the mean

EGPRS

Interval Type

0~50

PL4

Persisten ce level 4 of the radio access priority. During MS access, the access priority of the MS is set. If the priority of SET the MS is Persisten GCELLP higher GBFDBSC6900 ce Level 4 RACH(Op than the 119110 tional) access priority of the MS, the cell allows the access of the MS. Otherwise , the cell rejects the access of the MS. The value "no use" indicates

Access

0_level(0 _level), 1_level(1 _level), 2_level(2 _level), 3_level(3 _level), 4_level(4 _level), 5_level(5 _level), 6_level(6 _level), 7_level(7 _level), Enumerati 8_level(8 on Type _level), 9_level(9 _level), 10_level( 10_level), 11_level( 11_level), 12_level( 12_level), 13_level( 13_level), 14_level( 14_level), 16_level( 16_level), nouse(no use)

PL8PSK

TRX 8PSK Level

Power attenuatio n level of the EDGE TRX. There are 50 power attenuatio n levels. At each level, the power is attenuate d by 0.2 dB. The SET spectrum GTRXDE requireme GBFDBSC6900 V(Optiona nts are 114201 l) met only when the power of an EDGE transceive r for transmitti ng 8PSK signals is lower than the average power for GMSK modulatio n.

EGPRS

Interval Type

0~50

PLPRD

Packet lost measure period [100ms]

ADD IPLOGIC BSC6900 PORT(Op tional)

PLTH

Packet ADD discard IPLOGIC BSC6900 threshold[ PORT(Op 0.001] tional)

Statistics period of the packet drop ratio. This parameter indicates the period for collecting the statistics informatio n about the packet drop ratio. Note that the unit of this parameter is 100 millisecon ds. The actual delay statistics period is the value of this parameter multiplied by 100 Packet drop ratio threshold for speed reduction. When the packet drop ratio exceeds the value of this parameter , the rate of the logical port is reduced. Note that the unit of this parameter is a thousand to one.

GBFD118605

IP QOS

Interval Type

1~100

GBFD118605

IP QOS

Interval Type

0~1000

SET PLYPOIN TCPLYV Play Point BSC6900 T OICE(Ma ndatory)

Point at which to play sound

GBFD111203

O&M of BSC

A(A Enumerati Interface), on Type ABIS(Abis Interface)

PLYSWIT Play CH Switch

SET TCPLYV BSC6900 OICE(Ma ndatory)

Whether to enable GBFDsound 111203 playing

O&M of BSC

Enumerati OFF(Off), on Type ON(On)

Duration of sound playing. If this parameter is set to 0, the sound is played repeatedl SET y. If this TCPLYV parameter PLYTIME Play Time BSC6900 OICE(Opt exceeds ional) the duration of the record file, the void sound is played for the exceeding CPU usage threshold for performa nce monitorin g. When the Performa average SET nce CPU FCCPUT PMCTHD monitor BSC6900 usage of HD(Optio control sliding nal) threshold windows reaches or exceeds the threshold, performa nce monitorin g is

GBFD111203

O&M of BSC

Interval Type

0~600

GBFD111705

GSM Flow Control

Interval Type

30~100

Packet queue usage threshold for performa nce monitorin g. When the Performa average SET nce packet FCMSGQ PMCTHD monitor BSC6900 queue THD(Opti control usage of onal) threshold sliding windows reaches or exceeds the threshold, performa nce monitorin g is Interval for sending cell Interval paging for SET group Sending GCELLS PMI BSC6900 packets Cell OFT(Man when Paging datory) Paging Package Messages Optimize at Abis Interface Number

GBFD111705

GSM Flow Control

Interval Type

30~100

GBFD110303

Paging

Interval Type

1~8

PMNUM

Number of Cell Pagings in One Package

of cell paging group SET packets GCELLS when GBFDBSC6900 OFT(Man Paging 110303 datory) Messages Optimize at Abis Interface is enabled

Paging

Interval Type

2~15

Cell PMOAFL Paging AG Package Switch

Whether to enable Paging Messages Optimize at Abis Interface. The BSC6900 combines multiple paging message SET s to a cell GCELLS paging GBFDBSC6900 OFT(Opti package 110303 onal) and then sends the package to the BTS. The package reduces header overhead and thus reducing the load on the Abis link.

Paging

CLOSE(F orced turnoff), OPEN(Fo Enumerati rced turnon Type on), AUTO(Sel fadaptive)

CPU usage threshold for recovery from performa nce monitorin Performa g. When SET nce the FCCPUT GBFDPMRTHD monitor BSC6900 average HD(Optio 111705 restore CPU nal) threshold usage of sliding windows is lower than the threshold, performa nce monitorin g is

GSM Flow Control

Interval Type

30~100

Packet queue usage threshold for recovery from performa nce monitorin Performa SET g. When nce FCMSGQ the GBFDPMRTHD monitor BSC6900 THD(Opti packet 111705 restore onal) queue threshold usage of sliding windows is lower than the threshold, performa nce monitorin g is Performa nce SET monitorin BSC6900 FCSW(O g flow ptional) control switch Whether to monitor GBFDthe RRM 111705 performa nce

GSM Flow Control

Interval Type

30~100

PMSW

GSM Flow Control

Enumerati ON, OFF on Type

PN

Port No.

SET SCUPOR Number MRFDBSC6900 T(Optiona of the port 210301 l)

Configura tion Interval Managem Type ent

0~11

PN

Port No.

SET ALMPOR BSC6900 T(Mandat ory)

Port No. of MRFDenvironm 210304 ent alarm

Faulty Interval Managem Type ent

1~32

PN

Port No.

Port No. of the XPU board. If SET you do XPUPOR not MRFDBSC6900 T(Optiona specify 210301 l) this parameter , all ports of the XPU

Configura tion Interval Managem Type ent

0~3

PN

Port No

PN

Port No

Number of the E1/T1 port on the Ater interface board. E1 ADD mode: ATERE1T 0~31 GBFDBSC6900 1(Mandat (EIU), 111801 ory) 0~62(OIU ), 0~251(P OUc). T1 mode: 0~31(EIU ), 0~83(OIU ADD AE1T1(M andatory) Port GBFDBSC6900 BLK number 111803 AE1T1(M andatory)

Ater Interface Interval 4:1 Type Multiplexi ng

0~335

A Interface Interval Circuit Type Managem ent

0~335

PN

BM Port No

It is one key field of identifying the block of the BLK Ater ATERE1T BSC6900 timeslot None 1(Mandat and ory) indicates the port No. of the Ater interface timeslot.

None

Interval Type

0~335

PN

Port No.

PN

Port No.

PN

Port No.

Port ADD number of PBE1T1( BSC6900 the E1/T1 Mandator of the Pb y) interface Number of the port where the alarm is generated , only the ports for data transmissi ADD on are OBJALM supported BSC6900 SHLD(Ma , such as ndatory) E1/T1 port, channeliz ed optical port tributary, optical port, and Ethernet port SET Indicates MSPCMD the port (Mandator number BSC6900 y) for SET running MSP(Man this datory) command

GBFD111203

O&M of BSC

Interval Type

0~335

MRFD210304

Faulty Interval Managem Type ent

0~335

None

None

Interval Type

0~7

PN

Port No.

SET E1/T1 BSC6900 E1T1LOP port (Optional) number

None

None

Interval Type

0~335

PN

Port No.

LOP E1T1(Opti E1/T1 onal) BSC6900 port SET number E1T1(Opti onal)

None

None

Interval Type

0~335

PN

Port No.

STR E1/T1 BSC6900 E1T1TST port (Optional) number

None

None

Interval Type

0~335

PN

Port No.

Indicates the port SET number OPTLOP( for BSC6900 None Mandator running y) this command .

None

Interval Type

0~7

PN

Port No.

SWP ETHPOR Port BSC6900 T(Mandat number ory)

GBFD111701

Board Interval Switchove Type r

0~11

PN

Port No.

SET Port BSC6900 OPT(Opti number onal)

None

None

Interval Type

0~7

PN

Port No.

SET COPTLN Port BSC6900 K(Optiona number l)

None

None

Interval Type

0~7

PN

Port No.

SET ETHPOR T(Optiona l) ADD ETHRED PORT(Ma Ethernet BSC6900 ndatory) port ADD ETHIP(M andatory) ADD ETHMEP( Mandator y)

None

None

Interval Type

0~11

PN

Physics port No.

PN

Port No.

ADD IPLOGIC BSC6900 PORT(Op tional) STR IPCHK(O ptional) STR BSC6900 ETHOAM LOOPTS T(Mandat ory)

FE/GE port number

None

None

Interval Type

0~11

Ethernet port

GBFD118609

IP Fault Detection Interval Based on Type BFD

0~11

PN

Port No.

PN

Port No.

STR FRPORT BSC6900 LOOP(Op tional) CHK E1T1CRS BSC6900 (Mandator y)

Port number E1/T1 port number

None

None

Interval Type

0~335

None

None

Interval Type

0~31

PN

Port No.

ADD Port BSC6900 BC(Mand number atory)

GBFD510002

Gb Over FR

Interval Type

0~335

PN

Port No.

Port ADD number of GBFDBSC6900 PBSL(Ma Pb 111203 ndatory) signaling link Port No. of the ADD BSC6900 BTSAUT GBFDBSC6900 board OPLAN(M 111202 connecte andatory) d with the BTS SET BTSENV ALMPOR T(Mandat Alarm MRFDBSC6900 ory) port 210304 ADD number BTSOBJA LMSHLD( Mandator SET BTSFOR BIDTS(M andatory) ADD BTSPPPL NK(Mand atory) ADD Number BTSMPL of the port GBFDBSC6900 NK(Mand on the 111202 atory) BTS side IMP BTSPPPL NK(Mand atory) IMP BTSMPL NK(Mand atory)

O&M of BSC

Interval Type

0~335

PN

Port No.

O&M of BTS

Interval Type

0~355

PN

Port No.

Faulty Interval Managem Type ent

0~255

PN

Port No.

O&M of BTS

Interval Type

0~23

PN

Port No.

SET BTSOML BSC6900 TS(Mand atory)

Number of the port GBFDon the 111202 BTS side

O&M of BTS

Interval Type

0~23

PN

Port No.

Number of the port ADD through BTSCON which the GBFDBSC6900 NECT(Ma BTS is 111202 ndatory) connecte d to the BSC6900 SET BTSETH PORT(Ma ndatory) BSC6900 IMP BTSDEVI P(Mandat ory)

O&M of BTS

Interval Type

0~335

PN

Port No.

Number of the FE GBFDor GE 111202 port

O&M of BTS

Interval Type

0~1

PN

Port No.

Number of the Ethernet port. The number ADD must be BTSETHL consistent GBFDBSC6900 CMEP(Ma with that 111202 ndatory) of the port carrying the FE connectio n of the IP BTS.

O&M of BTS

Interval Type

0~1

PN

Port No.

STR Port BSC6900 BTSTST( number Optional)

GBFD111202

O&M of BTS

Interval Type

0~255

Maximum transmissi on delay of the POC service (push to talk over cellular). The transmissi on delay of the POC service Transmis SET must be sion GCELLP POCDEL relatively GBFDDelay of BSC6900 SOTHER AY 119905 small. POC PARA(Op The Service tional) network side must support the function of detecting the POC service type and reduce the delay through related processin

PoC QoS

Interval Type

250~650

Maximum bandwidth of the POC service (push to talk over cellular). The transmissi on delay of the POC service must be SET relatively Max. GBR GCELLP POCGBR GBFDsmall. for POC BSC6900 SOTHER MAX 119905 The Service PARA(Op network tional) side must support the function of detecting the POC service type and reduce the delay through related processin g to meet

PoC QoS

Interval Type

6~120

SET Min. GBR GCELLP POCGBR for POC BSC6900 SOTHER MIN Service PARA(Op tional)

PocSup

POC Support

SET GCELLP BSC6900 SOTHER PARA(Op tional)

Minimum bandwidth of the POC service (push to talk over cellular). The transmissi on delay of the POC service must be relatively small. The network side must support the function of detecting the POC service type and reduce the delay through related processin g to meet Whether to support the push to talk over cellular (POC) service

GBFD119905

PoC QoS

Interval Type

6~120

GBFD119905

NotSuppo rt(Not Enumerati PoC QoS Support), on Type Support(S upport)

This parameter specifies a condition for generatin g a BTS alarm. When the output power of a TRX of a transmitte Power SET r is lower PODECT Output GCELLO than a GBFDBSC6900 HRES Reduction THEXT(O fixed 111202 Threshold ptional) level, an error is generated . This parameter and "Power output error threshold" indicate the two threshold s of the error. If this

O&M of BTS

Interval Type

0~9

This parameter specifies a condition for generatin g a BTS alarm. When the output power of a TRX of a transmitte Power SET r is lower POERRT Output GCELLO than a GBFDBSC6900 HRES Error THEXT(O fixed 111202 Threshold ptional) level, an error is generated . This parameter and "Power output reduction threshold" indicate the two threshold s of the error. If this Rollback ADD Descriptio POINTDE Point ROLLBA n of the MRFDBSC6900 SINFO Descriptio CKPOINT rollback 210301 n (Optional) point BEG ROLLBA CK(Mand atory) BEG FORWAR BSC6900 D(Mandat ory) ADD ROLLBA CKPOINT (Mandator y)

O&M of BTS

Interval Type

0~9

Configura tion String Managem Type ent

None

Rollback POINTNA Point ME Name

Name of the rollback point

MRFD210301

Configura tion String Managem Type ent

None

Port

ADD FTPSCLT Destinatio BSC6900 DPORT( n Port Mandator y)

PORT

Port

SWP BSC6900 BTSRING (Optional)

PORT

Port

SWP BTSOML BSC6900 LINK(Opti onal)

This port is provided by the FTP server to be visited by the Number of the port where to set up the link after the BTS ring is swapped. If this parameter is set to 0, the BTS works on a forward ring. If this parameter is set to 1, the BTS works on a backward Number of the port where to set up the link after the main and backup OMLs of the BTS are swapped

GBFD111203

O&M of BSC

Interval Type

21~65535

GBFD117801

Ring Interval Topology Type

0~1

GBFD113728

OML Backup

Interval Type

0~1

DXX In PORTNO Port No.

ADD Number DXXCON GBFDBSC6900 of the NECT(Ma 111203 DXX port ndatory)

O&M of BSC

Interval Type

0~15

Maximum ADD PORTNU DXX Port number of GBFDBSC6900 DXX(Opti M Number ports on 111203 onal) the DXX

O&M of BSC

Interval Type

1~16

Port PORTPR protocol OTYPE type

ADD PORTFL Port BSC6900 OWCTRL protocol PARA(Ma type ndatory)

None

None

Enumerati IP, HDLC on Type

Panel PortSwitc Port h Switch

SET XPUPOR BSC6900 T(Mandat ory)

Whether to enable the panel MRFDport of the 210301 XPU board

Configura CLOSE(C tion Enumerati lose), Managem on Type OPEN(Op ent en)

Indicates the type of the physical port used by the local maintena nce point ADD in the PORTTY ETHMEP( GBFDPort Type BSC6900 maintena PE Mandator 118630 nce y) group. FE indicates the FE port and TRUNK indicates the aggregati on group.

Ethernet OAM

Enumerati ETHER, on Type TRUNK

Type of the port. If this parameter is set to "TOPEXT OUTPOR T", the local E1/T1 ports are used to extend the transmissi ADD on of BTSTOP PORTTY MRFDother Port Type BSC6900 CONFIG( PE 211501 boards. Mandator That is, y) the timeslots on the source E1/T1 port are used by other boards through the extended E1/T1 port. If this Whether to transmit the 2Quater SET 2Quater Message GCELLC message POS2QU GBFDTransmis BSC6900 CUTRAN on the ATER 114323 sion SYS(Opti BCCH Channel onal) Norm channel or the BCCH Ext channel LOD BTSPAT CH(Mand Patch Type of atory) GBFDPOT Operation BSC6900 the patch CON 111202 Type operation BTSPAT CH(Mand atory)

TOPEXT OUTPOR IP-Based T(TOP 2G/3G CoExtended Transmis Enumerati Out Port), sion on on Type TOPEXTI Base NPORT(T Station OP Side Extended In Port)

2G/3G BCCHNor Cell m(BCCH Reselecti Enumerati Norm), on Based on Type BCCHExt on MS (BCCHEx State t)

O&M of BTS

BYBTSTY PE(By Enumerati BTS on Type Type), BYBTS(B y BTS)

POWER

Rated Power

Rated maximum output power of the diesel engine. SET Refer to BTSAPM GBFDBSC6900 the rated UBP(Opti 111202 output onal) power described on the diesel engine label.

O&M of BTS

Interval Type

1~1000

ADD POWER_ Switch for Relay BSC6900 EMU(Opti RELAY1 Relay 1 switch 1 onal)

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

ADD POWER_ Switch for Relay BSC6900 EMU(Opti RELAY2 Relay 2 switch 2 onal)

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

ADD POWER_ Switch for Relay BSC6900 EMU(Opti RELAY3 Relay 3 switch 3 onal)

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

ADD POWER_ Switch for Relay BSC6900 EMU(Opti RELAY4 Relay 4 switch 4 onal)

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

ADD POWER_ Switch for Relay BSC6900 EMU(Opti RELAY5 Relay 5 switch 5 onal)

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

ADD POWER_ Switch for Relay BSC6900 EMU(Opti RELAY6 Relay 6 switch 6 onal)

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

Battery SET Battery POWERC Shunt BTSPMU current GBFDURRENT BSC6900 Coefficien BP(Optio shunt 111202 DIV t nal) coefficient Power attenuatio n level of timeslot 7 of the BCCH in 16QAM. The attenuatio n level ranges from 0 to 16QAM SET 50, with POWERR Transmitt GCELLB the step GBFDEDUCE1 er Power BSC6900 ASICPAR of 0.2 dB. 510804 6QAM Reduce A(Optiona When the Level l) EDGE TRX sends signals in 16QAM, the transmit power must be lower than the mean power in

O&M of BTS

Interval Type

0~1000

Downlink Interval EGPRS2Type A

0~50

Power attenuatio n level of timeslot 7 of the BCCH in 32QAM. The attenuatio n level ranges from 0 to 32QAM SET 50, with POWERR Transmitt GCELLB the step GBFDEDUCE3 er Power BSC6900 ASICPAR of 0.2 dB. 510804 2QAM Reduce A(Optiona When the Level l) EDGE TRX sends signals in 32QAM, the transmit power must be lower than the mean power in Power SET type BTSPMU GBFDBSC6900 managed BP(Optio 111202 by the nal) PMU

Downlink Interval EGPRS2Type A

0~50

POWERT Power YPE Type

O&M of BTS

Cabinet POWERT Power YPE System Type

SET BTSPOW BSC6900 ERTYPE( Optional)

Type of the power supply GBFDsystem of 111202 the cabinet

O&M of BTS

POWER_ 48_24(48/ 24 Power Module), Enumerati POWER_ on Type 240_24(2 40/24 Power Module) 220VAC( 220V AC), Enumerati N48VDC(on Type 48V DC), P24VDC( +24V DC)

POWL

Power Level

This parameter specifies the transmit power level of the TRX. The greater this parameter is, the smaller the SET transmit GTRXDE power is. MRFDBSC6900 V(Optiona When this 210301 l) parameter is set to "0", the transmit power level of the TRX is the greatest. Each time this parameter increases by one level, the transmit

Configura tion Interval Managem Type ent

0~13

POWT

Power Type

This parameter specifies the maximum transmit power supported by the SET power GTRXDE MRFDBSC6900 amplifier V(Optiona 210301 of the l) TRX. The macro BTS and the mini BTS support different power levels.

ADD BTSPPPL PPP NK(Optio Frame nal) PPPEAAT Error BSC6900 IMP Alarm BTSPPPL Threshold NK(Optio nal)

When the number of error frames on the PPP layer reaches GBFDthe value 118611 of this parameter , the frame error alarm is generated

80W(80W ), 63W(63W ), 60W(60W ), 55W(55W ), 50W(50W ), 45W(45W ), 40W(40W ), 31W(31W Configura ), tion Enumerati 30W(30W Managem on Type ), ent 27W(27W ), 26W(26W ), 25W(25W ), 24W(24W ), 21W(21W ), 20W(20W ), 19W(19W ), 18W(18W ),

Abis IP over E1/T1

Interval Type

0~100

ADD PPP BTSPPPL Frame NK(Optio PPPEAD Error nal) BSC6900 T Alarm IMP Clearance BTSPPPL Threshold NK(Optio nal)

PPPLNK N

PPP link No.

ADD BSC6900 PPPLNK( Optional)

When the number of error frames on the PPP layer decrease GBFDs to the 118611 value of this parameter , the frame error alarm is GBFDPPP link 118611 number of GBFDBSC. 118622 GBFD118611 GBFD118622

Abis IP over E1/T1

Interval Type

0~100

Abis IP over Interval E1/T1 Type A IP over E1/T1 Abis IP over Interval E1/T1 Type A IP over E1/T1

0~499

PPPLNK N

ADD PPP subPPP link BSC6900 MPLNK(O link No. number ptional)

0~499

PPPLNK N

PPP link No.

ADD IPLOGIC PPP link BSC6900 PORT(Op number tional)

None

None

Interval Type

0~499

PPPLNK N

ADD BTSPPPL NK(Mand atory) ADD BTSMPL NK(Mand Number PPP Link atory) GBFDBSC6900 of a BTS No. IMP 118611 PPP link. BTSPPPL NK(Mand atory) IMP BTSMPL NK(Mand atory)

Abis IP over E1/T1

Interval Type

0~15

ADD PPPLNK( Optional) PPPMUX PPP mux BSC6900 ADD MPGRP( Optional)

PQNUM

Priority queue number

ADD PORTFL BSC6900 OWCTRL PARA(Op tional)

Whether to enable the PPP frame multiplexi ng function. If this parameter is set to ENABLE, the PPP frame multiplexi ng function is enabled. If this parameter is set to DISABLE, the PPP frame multiplexi ng This parameter applies to the FG2a and GOUa boards. For the FG2c, GOUc, or POUc board, this parameter is always

GBFD118611 GBFD118622

Abis IP Disable(D over Enumerati isable), E1/T1 on Type Enable(E A IP over nable) E1/T1

None

None

Interval Type

0~5

This parameter specifies whether the preempte d call is released after the handover failure. If this parameter is set to Preempte No, MSs d Call Not SET with high PREEMF Released OTHSOF priorities GBFDORHONO BSC6900 After TPARA(O can 115001 TREL Handover ptional) access Failure the network preferenti ally, but the preempte d call drops; if this parameter is set to Yes, the preempte d call is not

Enhanced Multi Level Preceden Enumerati NO(No), ce and on Type YES(Yes) Preemptio n(EMLPP )

This parameter specifies whether to preempt PDCHs when no TCH is available PDCH during the Preemptio handover n Allowed SET of the PREEMF During OTHSOF preempte GBFDORHOPD BSC6900 Handover TPARA(O d call. 115001 CH Due to ptional) When this Preemptio parameter n is set to Yes, the call drop rate of the preempte d call is decrease d, but the rate of PS services is If this parameter is set to ON, the BSC initiates a TCHF Emergenc SET preemptio PREEMP y Call GCELLC n when TIONPER Preemptio BSC6900 CAD(Opti receiving MIT n onal) a link Permitted establish ment indication from an MS in an emergenc y call.

Enhanced NOT_ALL Multi OWED(N Level ot Preceden Enumerati Allowed), ce and on Type ALLOWE Preemptio D(Allowed n(EMLPP ) )

GBFD110202 GBFD110521

Emergenc y Call Service (TS12) Enumerati OFF(Off), Guarante on Type ON(On) ed Emergenc y Call

Sampling rate of prePreproces SET processe PREMRS s MR GMRCTR GBFDBSC6900 d AMPLE Sample L(Optiona 110802 measure Ratio l) ment reports.

Preprocessin g of Interval Measure Type ment Report

1~255

PRI

Route Priority

ADD BTSIPRT( Optional) BSC6900 IMP BTSIPRT( Optional)

Priority of a route. A smaller value of this parameter indicates a higher priority. GBFDThe BTS 118601 preferenti ally selects the route with a high priority to transfer informatio

Abis over Interval IP Type

0~255

Packet PRIACCT Access HR Priority

Access priority of the MS that is allowed to access the cell. The MS sends the packet channel request containing the 2-bit radio SET priority GCELLP message. BSC6900 SBASE(O The ptional) priority of the 2-bit radio priority message ranges from 1 to 4 in descendin g order. During the MS access, the BSC compares the radio This

GBFD111101 GBFD114101

0(No packet access), 3(Packet access of level 1), 4(Packet System access of Informatio Enumerati levels 1n Sending on Type 2), GPRS 5(Packet access of levels 13), 6(Packet access of level 1-4)

Support Priority PRIFCEN Based Flow Control

parameter specifies whether to support flow control based on SET priority. BSCFCP GBFDBSC6900 When this ARA(Opti 111705 parameter onal) is set to on, the system preferenti ally admits the calls initiated

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

Transfer PRIMME Original SPPT MR

Whether the BTSs send the original measure ment reports to the BSC after preprocessin g them. SET When this GCELLH GBFDBSC6900 parameter OCTRL(O 110802 is set to ptional) YES, the BTSs sends the original and preprocesse d measure ment reports to the BSC.

Preprocessin g of Enumerati NO(No), Measure on Type YES(Yes) ment Report

Printing control threshold. If the CPU usage of sliding SET Print windows PRINTCT FCCPUT GBFDcontrol BSC6900 reaches HD HD(Optio 111705 threshold or nal) exceeds the threshold, printing flow control is triggered

GSM Flow Control

Interval Type

30~100

SET Print PRINTCT FCMSGQ control BSC6900 HD THD(Opti threshold onal)

SET Print PRINTRT FCCPUT restore BSC6900 HD HD(Optio threshold nal)

SET Print PRINTRT FCMSGQ restore BSC6900 HD THD(Opti threshold onal)

PRINTS W

Print Flow SET control BSC6900 FCSW(O switch ptional)

Printing control threshold. When the packet queue usage of sliding windows reaches or exceeds the threshold, printing flow control is triggered on the Printing control threshold. If the CPU usage of sliding windows is lower than the threshold, printing flow control on the serial port is Printing control threshold. When the packet queue usage of sliding windows is lower than the threshold, printing flow control on the serial port is stopped. Whether to control the printing flow on the serial port

GBFD111705

GSM Flow Control

Interval Type

30~100

GBFD111705

GSM Flow Control

Interval Type

30~100

GBFD111705

GSM Flow Control

Interval Type

30~100

GBFD111705

GSM Flow Control

Enumerati ON, OFF on Type

PRIOR

Cell Priority

This parameter controls handover between cells at the same layer. Generally, the cells at the same SET layer are GCELLB set with BSC6900 ASICPAR the same A(Optiona priority. If l) the cells at the same layer have different priorities, a cell with a smaller priority value has a higher priority.

GBFD110601 GBFD510501

PRIOR

Cell Priority

This parameter controls the handover s among cells on a same layer. A smaller priority ADD value GEXT2G indicates BSC6900 CELL(Opt a higher ional) priority. Cells with higher priorities are preferenti ally selected as the handover target cells.

PRIOR1(Priority1), PRIOR2(Priority2), PRIOR3(Priority3), PRIOR4(Priority4), PRIOR5(PriorityHUAWEI 5), I PRIORHandover Enumerati 6(PriorityHUAWEI on Type 6), II PRIORHandover 7(Priority7), PRIOR8(Priority8), PRIOR9(Priority9), PRIOR10(Priority10), PRIOR11(Priority11), PRIOR-

GBFD110601 GBFD510501

Prior-1, Prior-2, Prior-3, Prior-4, Prior-5, HUAWEI Prior-6, I Prior-7, Handover Enumerati Prior-8, HUAWEI on Type Prior-9, II Prior-10, Handover Prior-11, Prior-12, Prior-13, Prior-14, Prior-15, Prior-16

Flex Abis SET PRIORAB Prior BTSFLEX ISLOADT Choose BSC6900 ABISPAR HRED Load A(Optiona Thred l)

SET Cell HCS GCELLS PRIORCL Prior BSC6900 ERVPAR ASS Class A(Optiona l)

If the static Abis resource load is greater than the value of "Fix Abis Prior Choose Abis Load Thred" and the dynamic Abis resource load is greater than the value of this parameter , the halfrate channel is preferred. Otherwise , the fullrate channel is preferred. Priority of the hierarchic al cell structure (HCS). 0: indicates the lowest priority; 7: indicates the highest priority.

GBFD117301

Flex Abis

Interval Type

0~100

GBFD114101

GPRS

0(0), 1(1), 2(2), 3(3), Enumerati 4(4), 5(5), on Type 6(6), 7(7), nouse(no use)

PRIORIT Route Y priority

ADD MTP3RT( Optional) BSC6900 ADD M3RT(Op tional)

Route priority. The highest priority is represent ed by 0.

GBFD111804 GBFD118602 GBFD118622

A Interface Protocol Interval Process Type A over IP A IP over E1/T1

0~99

Priority of the signaling link. 0 ADD indicates MTP3LN the Signalling K(Optiona highest PRIORIT link BSC6900 l) priority. A Y priority ADD lowM3LNK(O priority ptional) link carries services only when the highRoute

GBFD111804 GBFD118602 GBFD118622

A Interface Protocol Interval Process Type A over IP A IP over E1/T1

0~99

PRIORIT Priority Y

priority. The boards FG2a, GOUa, UOIa(IP), FG2c, and GOUc support the configurat ion of routes with ADD different BSC6900 IPRT(Man None priorities. datory) Suppose two or more routes are configure d and their addresse s and masks are the same, and the addresse s of the next hops

None

Enumerati HIGH, on Type LOW

Preferenti al customize d Preferenti detection al SET PRIVATE type when Customiz BTSOTH GBFDPROBEF BSC6900 the ed PARA(Ma 118601 ST customize Detection ndatory) d Type sequence is used for port detection. Number of customize d detection types involved when the customize d sequence is used for port Subsidiar y customize d detection type when the customize d sequence is used for port detection. This parameter is valid only when Number of Customiz ed Detection Name of the private key file

TDME1_ O(TDM E1 0 Port), TDME1_1 (TDM E1 1 Port), Abis over Enumerati FE_E(FE IP on Type Electric Port), FE_O(FE Optical Port), IPOE(IP over E1)

Number of SET PRIVATE Customiz BTSOTH PROBEN BSC6900 ed PARA(Ma UM Detection ndatory) Types

GBFD118601

Abis over Enumerati 1(1), 2(2) IP on Type

Subsidiar y SET PRIVATE Customiz BTSOTH PROBES BSC6900 ed PARA(Ma ND Detection ndatory) Type

GBFD118601

TDME1_ O(TDM E1 0 Port), TDME1_1 (TDM E1 1 Port), Abis over Enumerati FE_E(FE IP on Type Electric Port), FE_O(FE Optical Port), IPOE(IP over E1)

PrivKey

Private Key File Name

SET CERTFIL BSC6900 E(Optiona l)

MRFD210305

Security String Managem Type ent

None

Port detection SET BTS Port sequence PROBES BTSOTH GBFDDetection BSC6900 used EQ PARA(Op 118601 Sequence during tional) BTS startup.

DEFAULT (Default Sequence ), CUSTOM Abis over Enumerati IZDE(Cus IP on Type tomized Sequence ), DISABLE( DISABLE)

PROT

SS7 protocol type

PROT

Frame Relay Protocol Type

Identifies the DSP protocol type, including ITUT(Inter national Telecom municatio n Union Telecom municatio n ADD Standardi BSC6900 N7DPC(O zation ptional) Sector), ANSI(Am erican National Standards Institute), and TTC(Tele communi cation Technolo gy Committe e Protocol type of the trunk frame. The setting of ADD this BSC6900 BC(Optio parameter nal) must be consistent with the setting at the SGSN side.

GBFD111804

A Interface Protocol Process

ITUT(ITU T), Enumerati ANSI(AN on Type SI), TTC(TTC)

GBFD510002

Gb Over FR

Q933(Q9 Enumerati 33), on Type ANSI(Ans i)

The transmissi on resource in the Abis timeslot is considere d as faulty only when the BTS detects that the Abis SET PROTEC Protection timeslot is BTSABIS GBFDTDELAYT Delay for BSC6900 faulty in TROP(Op 111202 IME Detection the delay. tional) The transmissi on resource in the Abis timeslot is considere d as normal when the BTS detects the Abis

O&M of BTS

Interval Type

5~300

Dyn. SET Turning GCELLD PROTEC Off Cell BSC6900 YNTURN TTIME Protection OFF(Opti Time onal)

TRX SET ProtectTi Power-on BSCDST meTrxPo BSC6900 Protection PA(Optio werOn Time nal)

This parameter specifies a period of time during which a cell cannot be enabled or disabled to prevent frequent cell enabling or disabling operation s. That is, after a cell is enabled, it cannot be disabled within the period of time specified by this parameter ; after a cell is This parameter is set to prevent the BSC from frequently enabling or disabling the TRX. After a TRX is powered on, the BSC is not allowed to disable the TRX within the period of

GBFD111610

Dynamic Interval Cell Type Power Off

0~255

GBFD111602

TRX Power Interval Amplifier Type Intelligent Shutdown

60~3600

PS

Port select

SET E1T1(Opti onal) Port BSC6900 CHK None selection E1T1CRS (Mandator y) SET Port BSC6900 OPT(Opti None selection onal)

None

PS

Port select

None

ALL(Sele ct all Enumerati ports), on Type SINGLE( Select one port) ALL(Sele ct all Enumerati ports), on Type SINGLE( Select one port) ALL(Sele ct all E1/T1 ports), PORT(Sel ect all E1/T1 ports of Enumerati one on Type channeliz ed optical port), SINGLE( Select one E1/T1 port)

PS

Port select

SET COPTLN Port BSC6900 None K(Mandat selection ory)

None

PSCHRA PS CHR BIS Abis

This parameter indicates SET whether GPSCHR to include BSC6900 None CTRL(Opt Abis ional) interface message s in PS CHR logs.

None

OFF(Not Enumerati Output), on Type ON(Outpu t)

PSCHRG PS CHR B Gb

This parameter indicates SET whether GPSCHR to include BSC6900 None CTRL(Opt Gb ional) interface message s in PS CHR logs.

None

OFF(Not Enumerati Output), on Type ON(Outpu t)

This parameter indicates whether to include internal informatio n in PS CHR logs. The internal informatio PS CHR SET n is the PSCHRIN Inner GPSCHR BSC6900 basic user None NINFO Informatio CTRL(Opt informatio n ional) n, including user type, MS mulitple timeslot capability, cause for TBF abnormal release, and

None

OFF(Not Enumerati Output), on Type ON(Outpu t)

This parameter indicates whether to include internal message s in PS CHR logs. The message s are generated in service data flow SET and PS CHR PSCHRIN GPSCHR transmitte Inner BSC6900 None NMSG CTRL(Opt d Message ional) between internal moudles, including uplink/do wnlink resource request, uplink/do wnlink resource indication, uplink/do wnlink resource rejection, This parameter indicates SET whether GPSCHR to include BSC6900 None CTRL(Opt Um ional) interface message s in PS CHR logs.

None

OFF(Not Enumerati Output), on Type ON(Outpu t)

PSCHRU PS CHR M Um

None

OFF(Not Enumerati Output), on Type ON(Outpu t)

GSM PS data PSDATA service DL downlink factor

GSM PS ADD data TRMFAC BSC6900 service TOR(Opti downlink onal) factor

GBFD118605

IP QOS

Interval Type

0~100

GSM PS data PSDATA service UL uplink factor

GSM PS ADD data TRMFAC BSC6900 service TOR(Opti uplink onal) factor

GBFD118605

IP QOS

Interval Type

0~100

Whether to support PS Handover (PS HO). The PS PS ADD HO is PSHOSU GBFDHandover BSC6900 NSE(Opti used to P 119502 Support onal) reduce the interval of the cell reselectio n of the MS.

NO(No PS Enumerati Support), Handover on Type YES(Sup port)

PSHPRID PS high ATAPAT PRI data H path

ADD PS high BSC6900 TRMMAP PRI data (Optional) path

None

None

BE, AF11, AF12, AF13, AF21, AF22, Enumerati AF23, on Type AF31, AF32, AF33, AF41, AF42, AF43, EF

PS high PSHPRID PRI data ATAPRI priority

ADD PS high BSC6900 TRMMAP PRI data (Optional) priority

None

None

Interval Type

0~7

Priority for PS services over the Abis interface in IP, IP over E1, or HDLC mode when PS preferred. When "Level of Preemptin PS High g ADD PRI Dynamic PSHPSP BSC6900 GCELL(O Service Channel" ptional) PRI is set to "No preempt of service TCHF" through the "SET GCELLP SCHM" command , PS services are assigned with a high Period for sending the packet message PSI. If the period is too long, the message PSI SET cannot be PSI1 GCELLP obtained PSI1RPT Repetition BSC6900 SI1(Optio in Period nal) realtime. If the period is too short, the message PSI is broadcast frequently , which occupies too much

GBFD111705

GSM Flow Control

Interval Type

0~7

GBFD111101 GBFD119102

System Informatio n Sending Interval Packet Type System Informatio n

1~16

Whether the BSC supports the state Support SET message PSISTAT PSI GCELLP GBFDBSC6900 PSI. The USIND Status SI1(Optio 119102 state Message nal) message PSI refers to PSI STATUS.

Packet System Enumerati NO(No), Informatio on Type YES(Yes) n

PSLPRID PS low ATAPAT PRI data H path

ADD PS low BSC6900 TRMMAP PRI data (Optional) path

GBFD118605

IP QOS

BE, AF11, AF12, AF13, AF21, AF22, Enumerati AF23, on Type AF31, AF32, AF33, AF41, AF42, AF43, EF

PS low PSLPRID PRI data ATAPRI priority

ADD PS low BSC6900 TRMMAP PRI data (Optional) priority

GBFD118605

IP QOS

Interval Type

0~7

PS Low PRI PSLPSVP Service PRI

Priority for PS services over the Abis interface in IP, IP over E1, or HDLC mode when CS preferred. When "Level of Preemptin g ADD Dynamic GBFDBSC6900 GCELL(O Channel" 111705 ptional) is set to "Preempt all dynamic TCHFs" or "No preempt of CCHs" through the "SET GCELLP SCHM" command , CS services are

GSM Flow Control

Interval Type

0~7

PS OtoU SET PSOTOU HO GCELLH RECEIVE Receive BSC6900 OIUO(Opt THRSH Level ional) Threshold

PSOUTM Mode ODE Control

SET GPSCHR BSC6900 CTRL(Opt ional)

Threshold of the receive level for triggering the handover GBFDof the PS 113201 services from the overlaid subcell to the underlaid subcell This parameter indicates the mode of exporting PS CHR logs. When the parameter is set to &quot;Co mmon User Mode&qu ot;, the PS CHR None logs of a specified cell are exported (the command is "SET GPSCHR SCOPE"); when the parameter is set to &quot;Sp ecified User Mode&qu ot;, the

Concentri Interval c Cell Type

0~63

None

COMMO NUSRM( Common User Enumerati Mode), on Type SPECUS RM(Speci fied User Mode)

SET PS RACH GCELLC PSRACH Min. BSC6900 CACCES ACCLEV Access S(Optiona Level l)

ADD PS PSRACJ BTSLOC Min.Acce BSC6900 ACCLEV GRP(Opti ss Level onal)

This parameter specifies the level threshold for the random access of the MS. If the receive level of the RACH burst in the PS domain is smaller than the value of PS RACH Min.Acce ss Level, the BTS regards this access as an invalid one and no decoding is performe d. If the receive Minimum voltage level for accessing PS services of the location group

GBFD111003

Radio Common Interval Channel Type Managem ent

-121~104

GBFD510104

Multi-site Interval Cell Type

-121~104

PSRCDS PS CHR W Switch

This parameter SET indicates GPSCHR BSC6900 whether None CTRL(Ma to record ndatory) PS CHR logs.

None

Enumerati OFF(OFF on Type ), ON(ON)

Maximum number of message PSRESR Max PS SET s in the EQMSGN Resource BSCFCP statistical GBFDBSC6900 UMINPE REQ Num ARA(Opti period for 111705 RIOD in Period onal) the arrival of PS resource requests Statistical PS SET period for PSRESR Resource BSCFCP the arrival GBFDEQSTAT REQ BSC6900 ARA(Opti of PS 111705 PERIOD Statistical onal) resource Period requests Whether to enable the DPSU0 to supply power for the BTS. In multimode scenario, the value of this GBFDparameter 111202 in one mode must be the same as the value of the correspon ding parameter in another

GSM Flow Control

Interval Type

10~10000

GSM Flow Control

Interval Type

100~6000 00

PSU0

SET BTSAPM UBP(Opti DPSU 0 onal) Configure BSC6900 SET d BTSDPM UBP(Opti onal)

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

PSU1

SET BTSAPM UBP(Opti DPSU 1 onal) Configure BSC6900 SET d BTSDPM UBP(Opti onal)

PSU2

SET DPSU 2 BTSAPM Configure BSC6900 UBP(Opti d onal)

Whether to enable the DPSU1 to supply power for the BTS. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another Whether to enable the DPSU2 to supply power for the BTS. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

PSU2

SET DPSU 2 BTSDPM Configure BSC6900 UBP(Opti d onal)

PSU3

SET DPSU 3 BTSDPM Configure BSC6900 UBP(Opti d onal)

Whether to enable the DPSU2 to supply power for the BTS. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another Whether to enable the DPSU3 to supply power for the BTS. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

PSU4

SET DPSU 4 BTSDPM Configure BSC6900 UBP(Opti d onal)

PSU5

SET DPSU 5 BTSDPM Configure BSC6900 UBP(Opti d onal)

Whether to enable the DPSU4 to supply power for the BTS. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another Whether to enable the DPSU5 to supply power for the BTS. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

PSU6

SET DPSU 6 BTSDPM Configure BSC6900 UBP(Opti d onal)

PSU7

SET DPSU 7 BTSDPM Configure BSC6900 UBP(Opti d onal)

Whether to enable the DPSU6 to supply power for the BTS. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another Whether to enable the DPSU7 to supply power for the BTS. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

Threshold of the receive level for triggering PS UtoO the SET PSUTOO HO handover GCELLH GBFDRECEIVE Receive BSC6900 of the PS OIUO(Opt 113201 THRSH Level services ional) Threshold from the underlaid subcell to the overlaid subcell This parameter specifies whether the BTS is allowed to enable the PSU Smart Control feature. When this parameter is set to YES, the BTS automatic GBFD111608 ally enables or disables the PSU according to the traffic volume to improve the efficiency of the PSU. When this parameter is set to Switch for the selfhealing of None the OMU processe s

Concentri Interval c Cell Type

0~63

PSU PSUTUR Turning NINGOFF Off ENABLE Enable

SET BTSOTH BSC6900 PARA(Op tional)

PSU Smart Control

NO(NO), Enumerati YES(YES on Type )

PSW

SelfSET healing SLFSLVS Switch for BSC6900 W(Option OMU al) Process

None

ON(ON), Enumerati OFF(OFF on Type )

PT

SET ALMPOR Port Type BSC6900 T(Mandat ory)

Port type of MRFDenvironm 210304 ent alarm Number of the port that provides the time informatio n on the SNTP server Cell Reselect Penalty Time (PT) is used to ensure the safety and validity of cell reselectio n because it helps to avoid frequent cell reselectio n. For details, see GSM Rec.

BOOL(BO Faulty Enumerati OL), Managem on Type VALUE(V ent ALUE)

PT

Port

ADD SNTPSR BSC6900 VINFO(M andatory)

GBFD111203

O&M of BSC

Interval Type

123~6553 4

PT

Cell Reselect Penalty Time

SET GCELLID BSC6900 LEAD(Opt ional)

GBFD110402

Basic Cell Interval ReType selection

0~31

PT

Subnet Protocol Type

ADD Subnet BSC6900 NSE(Man protocol datory) type

GBFD119001

Gb Interface Function

GB_OVE R_FR(Gb Enumerati over FR), on Type GB_OVE R_IP(Gb over IP)

PT

SET BTSENV Alarm Port Type BSC6900 ALMPOR port type T(Optiona l)

MRFD210304

BOOL(BO Faulty Enumerati OL), Managem on Type VALUE(V ent ALUE)

SET Line PTCODE Line code BSC6900 E1T1(Opti coding onal) method

None

None

B8ZS(B8 ZS), HDB3(HD Enumerati B3), on Type AMI(AMI), AMI_ZCS (AMI_ZC S)

PTRXT

Frame SET Receiving receive BSC6900 E1T1(Opti frame None Structure onal) structure

None

E1_DOU BLE_FRA ME(E1_D OUBLE_F RAME), E1_CRC4 _MULTI_ FRAME(E 1_CRC4_ MULTI_F RAME), Enumerati T1_SUPE on Type R_FRAM E(T1_SU PER_FR AME), T1_EXTE NDED_S UPER_F RAME(T1 _EXTEN DED_SU PER_FR AME)

PTTXT

Frame SET Sending send BSC6900 E1T1(Opti frame Structure onal) structure

None

None

PTTYPE

SET Frame Frame BSC6900 E1T1(Opti Structure structure onal)

None

None

E1_DOU BLE_FRA ME(E1_D OUBLE_F RAME), E1_CRC4 _MULTI_ FRAME(E 1_CRC4_ MULTI_F RAME), Enumerati T1_SUPE on Type R_FRAM E(T1_SU PER_FR AME), T1_EXTE NDED_S UPER_F RAME(T1 _EXTEN DED_SU PER_FR AME) E1_DOU BLE_FRA ME(E1_D OUBLE_F RAME), E1_CRC4 _MULTI_ FRAME(E 1_CRC4_ MULTI_F RAME), Enumerati T1_SUPE on Type R_FRAM E(T1_SU PER_FR AME), T1_EXTE NDED_S UPER_F RAME(T1 _EXTEN DED_SU PER_FR AME)

PTUID

HDLC Path Index In BTS

ADD BTSABIS HDLCPA TH(Mand atory) ADD BTSBIND BSC6900 2HDLCP ATH(Man datory) ADD GTRXBIN D2HDLC PATH(Ma ndatory)

Number of a BTS HDLC GBFDpath. It is 118401 unique in one [BTS].

Abis Transmis Interval sion Type Optimizati on

0~15

PTYPE

SET ETHPOR Ethernet Port type BSC6900 T(Mandat port type ory)

None

None

Enumerati FE, GE on Type

PTYPE

Power System Type

Power system type. When the PMU is installed on the rack, you can select the custom power system type. SET In multiBTSAPM GBFDBSC6900 mode UBP(Opti 111202 scenario, onal) the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another

O&M of BTS

APM100( APM100), APM200( APM200), APM30(A PM30), EPS4890( EPS4890) Enumerati , on Type EPS4815( EPS4815) , SC48200( SC48200) , CUSTOM (CUSTO M)

PubCert

SET Certificate CERTFIL BSC6900 File Name E(Optiona l)

Name of the MRFDcertificate 210305 file

Security String Managem Type ent

None

PV

BTS Patch Version

PV

Patch Version

This parameter specifies the patch version loaded to the BTS. This parameter can be set to only a hot patch version. You can SET use either BTSAUT GBFDof the BSC6900 ODLDAC following 111202 TINFO(O methods ptional) to query the version number of the BTS hot patch. Method 1: If the BTS hot patch is download ed to the OMU through the MML LOD BTSPAT CH(Mand Number atory) of the GBFDBSC6900 CON patch 111202 BTSPAT version CH(Mand atory)

O&M of BTS

String Type

None

O&M of BTS

String Type

None

Period timer of PVC utilization report. This timer PVC SET is started PVCUSE Utilization BSCPSS during GBFDRATETIM Report BSC6900 OFTPAR initializati 510002 ER Period A(Optiona on. When Timer l) the timer expires, the PVC utilization informatio n is reported. SET Private Private CERTFIL MRFDKey BSC6900 key E(Mandat 210305 Password password ory) ADD OP(Mand atory) DLD LICENSE Password BSC6900 (Mandator y) ULD LICENSE (Mandator DLD RETANT CFG(Man datory) ULD BTSDEV FILE(Man datory) DLD User BSC6900 BTSPAT Password CH(Mand atory) ULD BTSLOG( Mandator y) DLD BTSSW( Mandator

Gb Over FR

Interval Type

1~65535

PWD

Security Password Managem None Type ent

PWD

GBFD111203 Password MRFD210305

O&M of BSC Password Security None Type Managem ent

PWD

User password for the FTP server. When the FTPServe r.exe file GBFDdownload 111202 ed through the LMT is installed, the user password is admin.

O&M of BTS

Password None Type

SET Minimum PwdMinL PWDPOL Password BSC6900 en ICY(Optio Length nal)

Minimum length of MRFDthe user 210305 password

Security Interval Managem Type ent

6~32

PWL

Power Level

STR BTSTST( Power BSC6900 Mandator level y)

GBFD111202

O&M of BTS

Interval Type

0~31

First PWRALM Alarm SSW1 Switch

First alarm SET switch of PWRALM power MRFDBSC6900 SW(Optio distributio 210304 nal) n monitorin g board

Faulty Bit Field Managem Type ent

Second PWRALM Alarm SSW2 Switch

Second alarm SET switch of PWRALM power MRFDBSC6900 SW(Optio distributio 210304 nal) n monitorin g board

BIT0, BIT1, BIT6, BIT7, BIT8, BIT9, BIT14, BIT15, BIT16, BIT17, BIT22, BIT23, BIT24, BIT25, BIT29, BIT0, BIT1, BIT2, BIT3, BIT4, BIT5, BIT6, BIT7, BIT8,

Faulty Bit Field Managem Type ent

Power PWRBCD Forecast ALLOWD Allowed

Whether to allow active power control. If this parameter is set to YES, the system performs power forecast in the process SET of initial GCELLP GBFDaccess BSC6900 WRBASI assignme 117602 C(Optiona nt or l) service channel activation during intra-BSC handover s, and sends the forecast initial power informatio n to the BTSs through

Active Power Control

Enumerati NO(No), on Type YES(Yes)

Whether to enable III Power SET the PWRCTR Control GCELLP optimized GBFDLOPTIMIZ BSC6900 Optimized WR3(Opti power 117601 EDEN Enable onal) control algorithm III Whether to enable power SET control GCELLP algorithm GBFDBSC6900 WRBASI 110703 II or C(Optiona power l) control algorithm III

HUAWEI III Power Enumerati NO(No), Control on Type YES(Yes) Algorithm

Power PWRCTR Control LSW Switch

PWR2(Po Enhanced wer Power Enumerati control II), Control on Type PWR3(Po Algorithm wer controlIII)

SET GCELLC Power PWRDIV BSC6900 CACCES Deviation S(Optiona l)

SET Power GCELLC PWRDIVI Deviation BSC6900 CACCES ND Indication S(Optiona l)

If a class 3 MS on the DCS1800 band does not receive the original power command after random access, the power that the MS uses is the MS maximum transmit power level plus the power calculated from the power deviation. For details, The MS does not receive the original power command after random access. This parameter indicates whether the power deviation is added to the class 3 MS on the DCS1800 band on the basis of the maximum MS transmit

GBFD111003

Radio Common Interval Channel Type Managem ent

0~3

GBFD111003

Radio Common Enumerati NO(No), Channel on Type YES(Yes) Managem ent

Location PWRLOC Group ATION Power Switch

SET GCELLS BSC6900 OFT(Opti onal)

PWRMO Power DE Class

ADD BTSBRD CAP(Man datory) BSC6900 ADD BTSRXU BRD(Opti onal)

Whether to enable the power amplifier for all location groups. 0x01 indicates that the TRX power amplifier is enabled for all location groups. 0x00 indicates that the TRX power amplifier is enabled for the GSM multicarrier base station standard. Together with the "Board Type" parameter , this parameter serves as an index field and uniquely determine s an entry of verificatio n threshold of the transmit bandwidth , receive bandwidth , and number of TRXs of an RXU board. This

GBFD510104

OnlyCurP wrLoc(Onl y Current Working Location TRXes be Multi-site Enumerati Turned Cell on Type On), ALLPwrL oc(All Location TRXes be Turned On)

GBFD111202

O&M of BTS

CLASS0( Class0), Enumerati CLASS1( on Type Class1), CLASS2( Class2)

Time interval between the time when the BTS detects that the external power supply is shut down and the PWROFF Power-off SET time when PROTEC Protect BTSBAKP the GBFDBSC6900 TSTARTT Start WR(Optio backup 111605 IME Time nal) power decrease function is started. This parameter is valid in the BTSs that supports the backup power decrease

Active Backup Power Control

Interval Type

0~720

PWRPRI Power ORALLO Priority W Allowed

When this parameter is set to YES, The BSC6900 preferenti ally uses the TRX with good powersaving performa nce according to the SET TRX GCELLC power GBFDBSC6900 HMGAD( priority 111005 Optional) reported by the BTS. Smaller priority value indicates better power saving quality. If the priority is of a great value, the BTS

Enhanced Channel Enumerati NO(No), Assignme on Type YES(Yes) nt Algorithm

PWRSPN Power R Finetune

SET GTRXDE BSC6900 V(Optiona l)

ANT_A PwrSwitc ALD hA Power Switch

SET BTSRXU BSC6900 BP(Optio nal)

Finetune of the TRX power. During the static finetune of the TRX power, the BSC adjusts the TRX power at a step of 0.2 dB. In some scenarios, the losses vary dependin g on the tributaries where the power is combined , and the power difference before and after the power output is not an When the ANT_A tributary antenna power switch is ON, it is allowed to configure related parameter s of the ANT_A tributary.

MRFD210301

DB0(0.0d B), DB2(0.2dB), DB4(0.4dB), DB6(0.6dB), DB8(0.8dB), Configura DB10(tion Enumerati 1.0dB), Managem on Type DB12(ent 1.2dB), DB14(1.4dB), DB16(1.6dB), DB18(1.8dB), Default(D efault)

GBFD111202 MRFD210601

O&M of BTS Connectio n with Enumerati OFF(OFF TMA on Type ), ON(ON) (Tower Mounted Amplifier)

ANT_B PwrSwitc ALD hB Power Switch

SET BTSRXU BSC6900 BP(Optio nal)

SET RET ALD PwrSwitc BTSRXU Power BSC6900 hRET BP(Optio Switch nal)

Min Q0MINDS DSCP of CP queue 0

SET QUEUEM BSC6900 AP(Optio nal)

When the ANT_B tributary antenna power switch is ON, it is allowed to configure related parameter s of the ANT_B tributary. When the RET tributary antenna power switch is ON, it is allowed to configure related parameter s of the RET tributary. Minimum DSCP of queue 0. The IP packets with DSCP in a relation that "Min DSCP of queue 0" <= DSCP <= 63 is added to queue 0.

GBFD111202 MRFD210601

O&M of BTS Connectio n with Enumerati OFF(OFF TMA on Type ), ON(ON) (Tower Mounted Amplifier)

GBFD111202

O&M of BTS

Enumerati OFF(OFF on Type ), ON(ON)

None

None

Interval Type

0~63

Min Q1MINDS DSCP of CP queue 1

SET QUEUEM BSC6900 AP(Optio nal)

Min Q2MINDS DSCP of CP queue 2

SET QUEUEM BSC6900 AP(Optio nal)

Min Q3MINDS DSCP of CP queue 3

SET QUEUEM BSC6900 AP(Optio nal)

Minimum DSCP of queue 1. The IP packets with DSCP in a relation that "Min None DSCP of queue 1" <= DSCP < "Min DSCP of queue 0" is added to queue 1. Minimum DSCP of queue 2. The IP packets with DSCP in a relation that "Min None DSCP of queue 2" <= DSCP < "Min DSCP of queue 1" is added to queue 2. Minimum DSCP of queue 3. The IP packets with DSCP in a relation that "Min None DSCP of queue 3" <= DSCP < "Min DSCP of queue 2" is added to queue 3.

None

Interval Type

0~63

None

Interval Type

0~63

None

Interval Type

0~63

Min Q4MINDS DSCP of CP queue 4

SET QUEUEM BSC6900 AP(Optio nal)

QCI

Qsearch C Initial

SET GCELLC BSC6900 CUTRAN SYS(Opti onal)

Minimum DSCP of queue 4. The IP packets with DSCP in a relation that "Min DSCP of queue 4" <= DSCP < "Min DSCP of queue 3" is added to queue 4. The IP packets with DSCP in a relation that 0 <= DSCP < "Min DSCP of queue 4" is added to queue 5. This parameter specifies the threshold of the signal level for cell reselectio n in connectio n mode before ""Qsearch C"" is obtained.

None

None

Interval Type

0~63

GBFD114301 GBFD114302

GSM/WC Use_Qse DMA arch_I(Us Interopera e bility Enumerati Qsearch_ GSM/TD- on Type I), SCDMA Always(Al Interopera ways) bility

MS Fast QCKMVH Moving OEN HO Allowed

SET GCELLH BSC6900 OBASIC( Optional)

MS FastSET QCKSTA moving GCELLH BSC6900 TCNT Watch OAD(Opti Cells onal)

Whether to enable the fast moving micro-cell handover algorithm. The fast moving micro-cell handover algorithm enables fast moving MSs to switch over to macrocells, thus reducing the This parameter is used in the P/N criteria decision: If an MS quickly passes through N out of P microcells lately, the BSC enables the fast moving micro-cell handover algorithm. This parameter correspon ds to the N in the P/N

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~10

A time threshold determine d based on the radius of a cell and the moving speed of an MS. If the MS crosses the cell in a time MS FastSET period QCKTIME moving GCELLH shorter BSC6900 TH Time OAD(Opti than this Threshold onal) threshold, the BSC concludes that the MS quickly passes through the cell. Otherwise , it concludes that the MS slowly passes the cell.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

This parameter is used in the P/N criteria decision: If an MS quickly passes through N out of P microMS FastSET cells QCKTRU moving GCELLH BSC6900 lately, the ECNT Valid OAD(Opti BSC Cells onal) enables the fast moving micro-cell handover algorithm. This parameter correspon ds to the P in the P/N

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~10

QI

This parameter specifies the level threshold for cell reselectio n in idle mode. In idle mode, if the signal level of the serving SET cell is GCELLC below [0, Qsearch I BSC6900 CUTRAN 7] or SYS(Opti above [8, onal) 15], the MS starts to search for 3G cells. For example, if this parameter is set to 5 and if the signal level of the serving cell is

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~15

For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in several Filter SET consecuti Length for GCELLC ve QLENSD BSC6900 TCH HMGAD( measure Qual. Optional) ment reports. This parameter indicates the number of measure ment reports used for the filtering of the signal quality on service or

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~32

QLENSI

For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in several Filter SET consecuti Length for GCELLC ve BSC6900 SDCCH HMGAD( measure Qual. Optional) ment reports. This parameter indicates the number of measure ment reports used for the filtering of the signal quality on signaling

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~32

Support QOSOPT QoS Optimize

Whether to support QoC optimizati on. The GSN equipmen t for the GPRS provides flexible QoS mechanis ms for different SET subscribe GCELLP GBFDrs. The BSC6900 SOTHER QoS level 119902 PARA(Op is also set tional) during subscripti on. The QoS control parameter s include: service priority, reliability level, delay level, and data throughpu

NO(Not QoS Enumerati Support), ARP&TH on Type YES(Sup P port)

QP

Qsearch P

This parameter specifies one threshold of the signal level for cell reselectio n in packet transfer mode. In packet SET transfer GCELLC mode, if BSC6900 CUTRAN the signal SYS(Opti level of onal) the serving cell is below [0, 7] or above [8, 15], the MS starts to search for 3G cells. For example, if this parameter is set to 5

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~15

QSEARC Qsearch HC C

In connectio n mode, if the signal level is below [07] or above [815], the MS starts to search for 3G cells. For example, if this SET parameter GCELLC is set to 5 BSC6900 CUTRAN and if the SYS(Opti signal onal) level of the serving cell is lower than 5, the MS starts to search for 3G cells; if this parameter is set to 10 and if the signal

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~15

QTRU QTRUCH Signal ANMANG Merge SWITCH Avoid Switch

This parameter is used to avoid allocating the calls whose signal strengths differ greatly to the same timeslot. The BSC measures SET the signal GCELLS merge BSC6900 OFT(Opti conditions onal) on each timeslot every 0.5 seconds. If the difference between the highest signal strength and the lowest signal strength on a

GBFD110601 GBFD510501

HUAWEI I NO(Close Handover Enumerati ), HUAWEI on Type YES(Ope II n) Handover

The P/N criteria is used to determine low downlink power for multidensity carriers. If the downlink power of a multiQtru density Down SET carrier QTRUDN Power GCELLC remains PWRLAS BSC6900 Inadequat HMGAD( low during TTIME e Last Optional) a Time consecuti ve P seconds out of N seconds, the downlink power of the multidensity carrier is considere d low. This parameter

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~16

The P/N criteria is used to determine low downlink power for multidensity carriers. If the downlink power of a multiQtru density Down SET carrier QTRUDN Power GCELLC remains PWRSTA BSC6900 Inadequat HMGAD( low during TTIME e Stat Optional) a Time consecuti ve P seconds out of N seconds, the downlink power of the multidensity carrier is considere d low. This parameter Whether MultiDensity QTRUPW TRX RSHARE Power Sharing

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~16

to use the statistical SET multiplexi GCELLC GBFDBSC6900 ng HMGAD( 111005 algorithm Optional) for multidensity power

NONE(No Enhanced ne), Channel Enumerati DYNAMIC Assignme on Type (Dynamic nt power Algorithm sharing)

Maximum number of times that the BTS finds that the air conditione r needs to be switched off. If the number of times that the BTS SET finds that Qualified QUALOF BTSAIRC the air GBFDTimes for BSC6900 FTIMES ON(Optio conditione 111202 Off nal) r needs to be switched off in the "CHKOFF TIMES" checks reaches this parameter , the BTS switches off the air conditione r.

O&M of BTS

Interval Type

3~20

Maximum number of times that the BTS finds that the air conditione r needs to be switched on. If the number of times that the BTS SET finds that Qualified QUALON BTSAIRC the air GBFDTimes for BSC6900 TIMES ON(Optio conditione 111202 On nal) r needs to be switched on in the "CHKONT IMES" checks reaches this parameter , the BTS switches on the air conditione r.

O&M of BTS

Interval Type

3~20

Step of downward power adjustme MAX SET nt QUALST Down Adj. GCELLP GBFDBSC6900 according EP PC Value WR2(Opti 110703 to the by Qual. onal) quality of the received signals

Enhanced Power Interval Control Type Algorithm

0~4

Whether to query Query the SET QUERYC Classmar classmark GCELLS MAFTERI k after In- BSC6900 of the call OFT(Opti NBSCHO BSC HO in an onal) Enabled incoming BSC handover

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

QUICKH OEN

Whether SET Quick to allow GCELLH GBFDHandover BSC6900 the fast OBASIC( 510102 Enable handover Optional) algorithm

Fast Enumerati NO(No), Move on Type YES(Yes) Handover

Auxiliary devices of rack 0. This parameter contains eight bits. The eight bits, from the most significant bit to the least significant bit, SubRack SET indicate R0AuxDe 0 Auxiliary BTSAUX whether GBFDBSC6900 v Equipmen EQP(Opti to install a 111202 t onal) voltage stabilizer, internal battery, transmissi on power supply, temperatu re control unit, auxiliary device 5, auxiliary device 6, auxiliary device 7, Whether SubRack to 0 Storage SET R0BatAllo configure GBFDBattery BSC6900 BTSBAT( w a battery 111202 Config Optional) rack for Permit rack 0

O&M of BTS

Bit Field Type

AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

Capacity of the SubRack SET battery R0BatCa 0 Storage BTSBAT( GBFDBSC6900 rack p Battery Mandator 111202 configure Capacity y) d for rack 0

O&M of BTS

INSIDE_1 00AH(100 AH Inside Storage Battery), INSIDE_5 0AH(50A H Inside Storage Battery), OUTSIDE _300AH(3 00AH Outside Storage Battery), Enumerati OUTSIDE on Type _400AH(4 00AH Outside Storage Battery), OUTSIDE _500AH(5 00AH Outside Storage Battery), OUTSIDE _650AH(6 50AH Outside Storage Battery),

Ratio of the maximum charging current of the battery pack configure d for rack 0 to the capacity of the battery SubRack pack. For SET 0 Storage example, R0BatCo BTSBAT( GBFDBattery BSC6900 assume eff Mandator 111202 Coefficien that the y) t battery pack has a capacity of 200 AH. If this parameter is set to 0.15C, the maximum charging current of the battery pack is 30 Type of the SubRack SET battery R0BatTyp 0 Storage BTSBAT( GBFDBSC6900 rack e Battery Mandator 111202 configure Type y) d for rack 0

O&M of BTS

007C(0.0 7C), Enumerati 010C(0.1 on Type 0C), 015C(0.1 5C)

O&M of BTS

INSIDE_B ATTERY(I nside Storage Enumerati Battery), on Type OUTSIDE _BATTER Y(Outside Storage Battery)

Auxiliary devices of rack 1. This parameter contains eight bits. The eight bits, from the most significant bit to the least significant bit, SubRack SET indicate R1AuxDe 1 Auxiliary BTSAUX whether GBFDBSC6900 v Equipmen EQP(Opti to install a 111202 t onal) voltage stabilizer, internal battery, transmissi on power supply, temperatu re control unit, auxiliary device 5, auxiliary device 6, auxiliary device 7, Whether SubRack to 1 Storage SET R1BatAllo configure GBFDBattery BSC6900 BTSBAT( w a battery 111202 Config Optional) rack for Permit rack 1

O&M of BTS

Bit Field Type

AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

Capacity of the SubRack SET battery R1BatCa 1 Storage BTSBAT( GBFDBSC6900 rack p Battery Mandator 111202 configure Capacity y) d for rack 1

O&M of BTS

INSIDE_1 00AH(100 AH Inside Storage Battery), INSIDE_5 0AH(50A H Inside Storage Battery), OUTSIDE _300AH(3 00AH Outside Storage Battery), Enumerati OUTSIDE on Type _400AH(4 00AH Outside Storage Battery), OUTSIDE _500AH(5 00AH Outside Storage Battery), OUTSIDE _650AH(6 50AH Outside Storage Battery),

Ratio of the maximum charging current of the battery pack configure d for rack 1 to the capacity of the battery SubRack pack. For SET 1 Storage example, R1BatCo BTSBAT( GBFDBattery BSC6900 assume eff Mandator 111202 Coefficien that the y) t battery pack has a capacity of 200 AH. If this parameter is set to 0.15C, the maximum charging current of the battery pack is 30 Type of the SubRack SET battery R1BatTyp 1 Storage BTSBAT( GBFDBSC6900 rack e Battery Mandator 111202 configure Type y) d for rack 1

O&M of BTS

007C(0.0 7C), Enumerati 010C(0.1 on Type 0C), 015C(0.1 5C)

O&M of BTS

INSIDE_B ATTERY(I nside Storage Enumerati Battery), on Type OUTSIDE _BATTER Y(Outside Storage Battery)

Auxiliary devices of rack 2. This parameter contains eight bits. The eight bits, from the most significant bit to the least significant bit, SubRack SET indicate R2AuxDe 2 Auxiliary BTSAUX whether GBFDBSC6900 v Equipmen EQP(Opti to install a 111202 t onal) voltage stabilizer, internal battery, transmissi on power supply, temperatu re control unit, auxiliary device 5, auxiliary device 6, auxiliary device 7, Whether SubRack to 2 Storage SET R2BatAllo configure GBFDBattery BSC6900 BTSBAT( w a battery 111202 Config Optional) rack for Permit rack 2

O&M of BTS

Bit Field Type

AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

Capacity of the SubRack SET battery R2BatCa 2 Storage BTSBAT( GBFDBSC6900 rack p Battery Mandator 111202 configure Capacity y) d for rack 2

O&M of BTS

INSIDE_1 00AH(100 AH Inside Storage Battery), INSIDE_5 0AH(50A H Inside Storage Battery), OUTSIDE _300AH(3 00AH Outside Storage Battery), Enumerati OUTSIDE on Type _400AH(4 00AH Outside Storage Battery), OUTSIDE _500AH(5 00AH Outside Storage Battery), OUTSIDE _650AH(6 50AH Outside Storage Battery),

Ratio of the maximum charging current of the battery pack configure d for rack 2 to the capacity of the battery SubRack pack. For SET 2 Storage example, R2BatCo BTSBAT( GBFDBattery BSC6900 assume eff Mandator 111202 Coefficien that the y) t battery pack has a capacity of 200 AH. If this parameter is set to 0.15C, the maximum charging current of the battery pack is 30 Type of the SubRack SET battery R2BatTyp 2 Storage BTSBAT( GBFDBSC6900 rack e Battery Mandator 111202 configure Type y) d for rack 2

O&M of BTS

007C(0.0 7C), Enumerati 010C(0.1 on Type 0C), 015C(0.1 5C)

O&M of BTS

INSIDE_B ATTERY(I nside Storage Enumerati Battery), on Type OUTSIDE _BATTER Y(Outside Storage Battery)

RA

RAC

The NS performs location managem ent based on routing areas during GPRS ADD packet GEXT2G services. MRFDBSC6900 CELL(Opt Each 210301 ional) routing area has a routing area identifier, which is broadcast as a system message. The NS performs location managem ent based on routing areas ADD during GEXT3G MRFDBSC6900 GPRS CELL(Opt 210301 packet ional) services. Each routing area has a routing area identifier. Identifies the SET routing GCELLG GBFDBSC6900 area of PRS(Opti 114101 the onal) current cell SET BTSAUT BSC6900 OPLANC FG(Optio nal) Route area of the current cell

Configura tion Interval Managem Type ent

0~255

RA

Route Area

Configura tion Interval Managem Type ent

0~255

RA

Routing Area

GPRS

Interval Type

0~255

RA

Route Area

GBFD510701

Compact BTS Automatic Interval Configura Type tion and Planning

0~255

RA

Route Area

ADD GCELLQ BSC6900 UICKSET UP(Optio nal)

Route area of the current cell

GBFD510701

Compact BTS Automatic Interval Configura Type tion and Planning

0~255

RA1

Route Area

SET BTSAUT BSC6900 OPLANC FG(Optio nal)

Route area of the current cell

GBFD510702

Compact BTS Interval Automatic Type Capacity Planning

0~255

This parameter specifies the level threshold for the random access of the MS. If the receive level of the RACH burst in the CS SET CS RACH domain is GCELLC RACHAC Min. GBFDsmaller BSC6900 CACCES CLEV Access than the 111003 S(Optiona Level value of l) CS RACH Min.Acce ss Level, the BTS regards this access as an invalid one and no decoding is performe d. If the receive

Radio Common Interval Channel Type Managem ent

-121~104

Level threshold of the MS random access for the BTS to determine the RACH busy state. When the SET RACHBU RACH receive GCELLC GBFDSYTHRE Busy BSC6900 level of CBASIC( 111003 D Threshold the Optional) random access burst timeslot is greater than this threshold, the BTS considers that the timeslot is busy.

Radio Common Interval Channel Type Managem ent

0~63

Average RACHLD RACH AVERSL Load OT Timeslot Number

Number of RACH burst timeslots in a RACH load measure ment. The value of this parameter SET indicates GCELLC GBFDBSC6900 the CCH(Opti 111003 interval onal) during which the BSC6900 determine s whether an RACH timeslot is busy. For details, see GSM Rec. 08.58.

Radio Common Interval Channel Type Managem ent

0~65535

Minimum voltage level for ADD CS accessing RACJAC BTSLOC GBFDMin.Acce BSC6900 CS CLEV GRP(Opti 510104 ss Level services onal) of the location group Routing RACOLO Area R Color Code Routing SET area color GCELLP BSC6900 code of SBASE(O the GPRS ptional) cell GBFD111101 GBFD114101

Multi-site Interval Cell Type

-121~104

System Informatio Interval n Sending Type GPRS

0~7

Whether Allow MS SET to allow RANDAC to Access GCELLR the MS to GBFDCESSRE to BSC6900 ESELECT access 114101 TRY Another PARA(Op another Cell tional) cell

GPRS

Enumerati NO(No), on Type YES(Yes)

Correlatio n threshold of the training sequence for the random access. As defined in the GSM recomme ndation, the SET Random system GCELLC RANERR Access GBFDcan BSC6900 CACCES THRED Error determine 111003 S(Optiona Threshold whether l) the received signals are random access signals of the MS and calculate the TA value by checking the correlatio

Radio Common Interval Channel Type Managem ent

0~255

Hysteresi s of cell selection in different routing area. When a standby or ready MS starts cell reselectio n, if the original Accessori SET cell and RARESE al GCELLR the target GBFDLECTHYS Hysteresi BSC6900 ESELECT cell are in 114101 T s of Cell PARA(Op the Selection tional) different routing area, the signal level of the neighbori ng cell must be greater that of the current cell. Their difference must be SET BTSETH BSC6900 PORT(Op tional) Port rate of the IP interface board

GPRS

0dB(0dB), 2dB(2dB), 4dB(4dB), 6dB(6dB), 8dB(8dB), 10dB(10d Enumerati B), on Type 12dB(12d B), 14dB(14d B), nouse(no use)

RATE

Rate

GBFD118601

10M(10M) , Abis over Enumerati 100M(100 IP on Type M), AUTO(Au to)

AMR RATECT Rate RLSW Control Switch

Switch for controlling the AMR rate. Value 0 indicates that C/I is SET used to GCELLC control BSC6900 CAMR(O the AMR ptional) rate. Value 1 indicates that BER is used to control the AMR rate.

GBFD115506 GBFD115507

AMR Coding ALG1(Alg Rate orithm I), Threshold Enumerati ALG2(Alg Adaptive on Type orithm II), Adjustme NONE(No nt ne) WB AMR

Is SET RATSCC RATSCC GCELLC HENABL H BSC6900 CAMR(O ED Function ptional) Enabled

Raw MR RAWMR Sample SAMPLE Ratio

SET GMRCTR BSC6900 L(Optiona l)

This parameter specifies whether the RATSCC H function is enabled during the call establish ment procedure . RATSCC H is used to dynamical ly reconfigur e the rate set of AMR while on a call. This parameter maps the versions Original measure ment report sampling rate (for each call, one out of four measure ment reports is collected)

GBFD115506 GBFD115701

AMR Coding Rate DISABLE( Threshold Enumerati Disable), Adaptive on Type ENABLE( Adjustme Enable) nt TFO

GBFD110801

Processin g of Interval Measure Type ment Report

1~255

Type of RBPTYP Rollback E Point

LASTRBP indicates the last rollback point. The system automatic ally takes the position where the current configurat ion command BEG is FORWAR executed MRFDBSC6900 D(Mandat as the 210301 ory) rollback point, and the user does not need to specify a rollback point. APPOINT RBP indicates the rollback point specified by the

LASTRBP (last rollbackpo Configura int), tion Enumerati APPOINT Managem on Type RBP(app ent ointed rollbackpo int)

RCDT

RUN Result BATCHFI Recording BSC6900 LE(Option Type al)

RCN

ADD BTSRXU CHAIN(M andatory) SET BTSBRE Chain No. BSC6900 AKPOINT (Mandator y) SPT BTSRXU CHAIN(M andatory)

Type of recording the execution result 1. REC_ALL : indicating that the execution results of all the command s are recorded no matter whether the command s are executed successfu lly. 2. REC_ER R: indicating that only the execution results of failed command Number of the RXU chain or ring. The value scope is 0~11 for NonSingleRA N BTS and 0~249 for SingleRA N BTS. The RXU chain No. is unique in the same BTS. A maximum of 12 RXU chains can be

GBFD111203

O&M of BSC

REC_ALL (Record All), REC_ER Enumerati R(Record on Type Errors), REC_NO N(Record None)

GBFD111202

O&M of BTS

Interval Type

0~249

RCN1

The first RXU chain CBN number First RXU BTSRXU when GBFDBSC6900 Chain No. CHAIN(M combining 111202 andatory) two RXU chains to be one RXU ring. The second RXU chain number when combining two RXU chains to be one RXU ring. RF receive mode of the TRX. The BTS3012, BTS3012 AE, BTS3012I I, BTS3006 C, and BTS3002 E do not support Main Diversity. The DBS3900 GSM and BTS3900 GSM support Four Diversity Receiver and Main

O&M of BTS

Interval Type

0~249

RCN2

CBN Second BTSRXU RXU BSC6900 CHAIN(M Chain No. andatory)

GBFD111202

O&M of BTS

Interval Type

0~249

RCVMD

Receive Mode

SET GTRXDE BSC6900 V(Optiona l)

MRFD210301

INDEPEN DENT(Ind ependent Receiver), DIVIDING (Dividing Receiver), Configura FOURDIV tion Enumerati ERSITY(F Managem on Type our ent Diversity Receiver), MAINDIV ERSITY( Main Diversity), NONE(No ne)

RDC

Speed reduction efficient of the logical port. When detecting link congestio n through Rate ADD IPPM, the down IPLOGIC system GBFDBSC6900 coefficient PORT(Op reduces 118605 [%] tional) the bandwidth rate of the logical port by using the value of the bandwidth multiplied by this

IP QOS

Interval Type

0~100

SET REASSE Allow GCELLC BSC6900 N Reassign CBASIC( Optional)

Whether to allow the reassign ment function

GBFD112501

TCH ReEnumerati NO(No), assignme on Type YES(Yes) nt

SET REASSF Frequenc GCELLC REQBAN y Band of BSC6900 CAD(Opti D Reassign onal)

RECEIVE SET ReceiveQ QUALTH GCELLH ualThrshA BSC6900 RSHAMR OIUO(Opt MRFR FR ional)

Whether to reassign the radio channels on a different band or on the same band. This can help minimize the decrease in service quality due to interferen ce, faulty TRX paths, or faulty project constructi ons. IUO cell receive quality threshold (AMRFR), which is used for IUO handover decision

GBFD112501

Same_Ba nd(Same TCH ReEnumerati Band), assignme on Type Diff_Band nt (Different Band)

GBFD113201 GBFD115501

Concentri Interval c Cell Type AMR FR

0~70

IUO cell receive quality RECEIVE SET threshold ReceiveQ QUALTH GCELLH (AMRHR) ualThrshA BSC6900 RSHAMR OIUO(Opt , which is MRHR HR ional) used for IUO handover decision

GBFD113201 GBFD115502

Concentri Interval c Cell Type AMR HR

0~70

SET RX_LEV RECLEV GCELLH Hysteresi BSC6900 HYST OIUO(Opt s ional)

SET RECLEV RX_LEV GCELLH BSC6900 THRES Threshold OIUO(Opt ional)

One of the parameter s that decide the underlay and overlay areas. The underlay and overlay areas are determine d by "RX_QUA L Threshold ", "RX_LEV Threshold ", One of the parameter s that decide the underlay and overlay areas. The underlay and overlay areas are determine d by "RX_QUA L Threshold ", "RX_LEV Threshold ",

GBFD113201

Concentri Interval c Cell Type

0~63

GBFD113201

Concentri Interval c Cell Type

0~63

RX_LEV RECLEV for UO UOHOAL HO LOW Allowed

Whether to use the downlink SET receive GCELLH GBFDBSC6900 level as a OIUO(Opt 113201 condition ional) in IUO handover decision

Concentri Enumerati NO(No), c Cell on Type YES(Yes)

With traffic control enabled, the BSC discards some paging message s. This RecordDi Record SET parameter scardedP Discarded OTHSOF GBFDBSC6900 specifies agingInfo Paging TPARA(O 111705 whether Flag Msg ptional) to record detailed informatio n of paging message s discarded by the BSC in Speed Decrease ADD reduction RECOVE rate alarm IPLOGIC GBFDBSC6900 alarm RTHD recover PORT(Op 118605 recovery threshold tional) threshold

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

IP QOS

Interval Type

20~99

SET RX_QUA RECQUA GCELLH L BSC6900 LTH OIUO(Opt Threshold ional)

RX_QUA SET RECQUA L for UO GCELLH LUOHOA BSC6900 HO OIUO(Opt LLOW Allowed ional)

One of the parameter s that decide the underlay and overlay areas. If "Enhance d Concentri c Allowed" is set to OFF, the underlay and overlay areas are determine d by "RX_QUA L Threshold ", "RX_LEV Threshold ", "RX_LEV Hysteresi s", "TA Whether to use the downlink receive quality as a condition in IUO handover decision

GBFD113201

Concentri Interval c Cell Type

0~70

GBFD113201

Concentri Enumerati NO(No), c Cell on Type YES(Yes)

RED

Backup

Whether ADD to back MRFDBSC6900 BRD(Man up the 210301 datory) data of the board

Configura tion Enumerati YES(YES Managem on Type ), NO(NO) ent

Interval to Interval Reduce for SET Transmis releasing BSCPSS ReduceTr sion GBFDthe BSC6900 OFTPAR ansBwInt Bandwidt secondar 111705 A(Optiona h when y links in l) Congeste the d congestio

GSM Flow Control

Interval Type

0~50

Number Secondar of y link Transmis SET bandwidth sion ReduceTr BSCPSS that is Bandwidt ansBwNu BSC6900 OFTPAR released h to m A(Optiona each time Reduce l) in the when congestio Congeste n state d Port for output LINE2(Th SET e actual REF2MC Port for BSC6900 CLK(Opti value LK2SRC LINE2 onal) range may differ on the LMT ) Back-up

GBFD111705

GSM Flow Control

Interval Type

0~768

MRFD210502

BSC/RNC Interval Clock Type

0~31

REF2MC Back-up LK2SRCB port for AK LINE2

port for output LINE2(Th SET e actual MRFDBSC6900 CLK(Opti 210502 value onal) range may differ on the LMT for Port ) output LINE1(Th SET e actual MRFDBSC6900 CLK(Opti value 210502 onal) range may differ on the LMT ) Back-up port for output LINE(The SET MRFDactual BSC6900 CLK(Opti 210502 value onal) range may differ on the LMT )

BSC/RNC Interval Clock Type

0~31

REF2MC Port for LKSRC LINE1

BSC/RNC Interval Clock Type

0~31

REF2MC Back-up LKSRCB port for AK LINE1

BSC/RNC Interval Clock Type

0~31

Switch of Switch of SET REF2MC panel MRFDpanel 2M BSC6900 CLK(Opti LKSW1 BITS1(2M 210502 BITS1 onal) )

BSC/RNC Enumerati OFF(OFF Clock on Type ), ON(ON)

Switch of Switch of SET REF2MC panel MRFDpanel 2M BSC6900 CLK(Opti LKSW2 BITS2(2M 210502 BITS2 onal) )

BSC/RNC Enumerati OFF(OFF Clock on Type ), ON(ON)

Whether to use SGSN clock source.O nly the Gb interface board needs to set this parameter . If the SGSN clock and the MSC Use clock REFUSE SET SGSN have LOCALCL BSC6900 CLK(Opti clock different K onal) source clock sources, the MSC clock must use the clock source of the SGSN clock. If the two clocks use the same clock source, this Region informatio n of the IP BTS configure d with local switching. Local Region SET switching REGION Informatio BSC6900 BTSLSW( can be n Optional) performe d between only the BTSs that have the same region informatio

MRFD210502

NO(NO), BSC/RNC Enumerati YES(YES Clock on Type )

GBFD117702

BTS Local Switch

Interval Type

0~95

ReHost REHOST Absolute ABSTIME Time

SET GREDGR Absolute PPRIMH GBFDBSC6900 time of reOSTPOLI 113725 homing CY(Mand atory)

BSC Node Compoun hour, min, Redunda d Type sec ncy

SET GREDGR REHOST Delay ReHostD PPRIMH GBFDDELAYTI BSC6900 time of reelayTime OSTPOLI 113725 ME homing CY(Mand atory)

BSC Node Interval Redunda Type ncy

1~3600

REHOST ReHost TYPE Type

SET GREDGR Policy PPRIMH GBFDBSC6900 type of reOSTPOLI 113725 homing CY(Mand atory)

Reinitializ ADD e REINITTB AISSCFG Neighbou BSC6900 L (Mandator r Cell y) Table

RELATE DCN

SET Associate BTSRXU d Board BSC6900 BP(Mand CN atory)

Whether to reinitialize the neighbori ng cell pair for software synchroni zation Cabinet number of the associate d module. The associate d two MRFUs or GRFUs must be in the same cell.

REHOST RIGHTN OW(ReH ostRightN BSC ow), Node Enumerati REHOST Redunda on Type DELAY(R ncy eHostDel ay), REHOST WHEN(R

GBFD118201

SoftNO(NO), Synchroni Enumerati YES(YES zed on Type ) Network

GBFD111202

O&M of BTS

Interval Type

0~62

Whether to enable the configurat ion of the "Extend Connectio n" attribute. Extend The Connectio SET "Extend RELATE n BTSDFC Connectio GBFDDFCUEN BSC6900 Configura UBP(Opti n" 111202 ABLED tion onal) attribute Enabled describes the cascading relationshi p of the DFCB, which helps the DFCU perform

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

Function to be SET RELATE Associate performe BTSRXU GBFDDMODFU d Board BSC6900 d by two BP(Optio 111202 NC Function associate nal) d modules

O&M of BTS

OFF(OFF ), POWERS HARING( Power Sharing Enumerati Between on Type Boards), RF_FH(R F Frequenc y Hopping Between

RELATE DSN

Slot SET Associate number of BTSRXU GBFDd Board BSC6900 the BP(Mand 111202 SN associate atory) d module

O&M of BTS

Interval Type

0~23

RELATE DSRN

Subrack SET Associate number of BTSRXU GBFDd Board BSC6900 the BP(Mand 111202 SRN associate atory) d module

O&M of BTS

Interval Type

0~255

Tributary Number of the DFCB that is cascaded to the DFCU. The "Extend SET Cascadin Connectio RELATE BTSDFC GBFDg BSC6900 n" DTRACK UBP(Opti 111202 Tributary attribute onal) describes the cascading relationshi p of the DFCB, which helps the DFCU perform ADD TRMMAP (Optional) GBFDREMARK Remark BSC6900 ADD Remark 118605 TRMFAC TOR(Man datory) Purpose Route use ADD descriptio REMARK descriptio BSC6900 IPRT(Man n of the None n datory) route record ADD NSVLRE BSC6900 MOTE(Ma ndatory) Remote NSVL ID GBFDof the Gb 118603 IP route

O&M of BTS

A(A), Enumerati B(B), on Type NONE(N ONE)

IP QOS

String Type

None

None

String Type

None

REMOTE Remote NSVLI NSVL ID

Gb over IP

Interval Type

0~1023

REP

Repeat

ADD GSMSCB BSC6900 (Mandator y)

SET Repeated REPEAT GCELLC Downlink BSC6900 DLFASET CBASIC( FACCH Optional)

A key parameter that indicates how many times the BSC6900 broadcast s cell message s. You can obtain the cell broadcast times by running the "DSP GSMSCB " command . The value When the cell supports Repeated Downlink FACCH, the BTS enables the repeated transmissi on of FACCH frames if the measured downlink quality is higher than "Repeate d Downlink FACCH

GBFD113602

Simplified Interval Cell Type Broadcast

0~65535

GBFD113721

Robust Air Enumerati NO(No), Interface on Type YES(Yes) Signalling

If the cell supports the Repeated Downlink FACCH function and the measured downlink Repeated SET quality is REPEAT Downlink GCELLC lower GBFDDLFATH BSC6900 FACCH CBASIC( than the 113721 RED Threshold Optional) downlink quality threshold, the BTS enables the repeated transmissi on of FACCH frames. When the cell supports Repeated Downlink SACCH, the BTS enables the repeated transmissi on of SACCH frames if the measured downlink quality is higher than the downlink quality threshold. Whether to reserve the binding of the alarm ID and the alarm port

Robust Air Interval Interface Type Signalling

0~7

SET REPEAT Repeated GCELLC BSC6900 SASET SACCH CBASIC( Optional)

GBFD113721

Robust Air Enumerati NO(No), Interface on Type YES(Yes) Signalling

SET BTSENV RESALMI Reserved BSC6900 ALMPOR D Alarm ID. T(Optiona l)

MRFD210304

Faulty Enumerati NO(No), Managem on Type YES(Yes) ent

Whether to perform resource checks on the resource usage system and resource managem ent system. SET Resource ResChec ResChec OTHSOF checks GBFDBSC6900 kAllowed kAllowed TPARA(O can 111203 ptional) prevent resource hanging in case of anomalies . Resource checks cover channel resources , transmit resources , and BSC

O&M of BSC

Enumerati NO(No), on Type YES(Yes)

Indicating that during cell reselectio n, the level of the target cell should meet the following condition: Level of Cell target cell SET Reselecti > [MAX RESELH GCELLN GBFDon BSC6900 (level of YST C2PARA( 116201 Hysteresi serving Optional) s cell, "Cell Reselecti on Level Threshold ") + "Cell Reselecti on Hysteresi s"]. In this way, pingpong handover s do not occur. NC2 cell SET reselectio GCELLN GBFDBSC6900 n interval C2PARA( 116201 in the Optional) same cell

NetworkControlled Interval Cell Type Reselecti on (NC2)

0~63

Cell RESELIN Reselect TERVAL Interval

NetworkControlled Interval Cell Type Reselecti on (NC2)

1~10

Normal SET RESELW Cell GCELLN ATCHPE Reselecti BSC6900 C2PARA( RIOD on Watch Optional) Period

Normal Cell RESELW SET Reselecti ORSENL GCELLN on BSC6900 EVTHRS C2PARA( Worsen H Optional) Level Threshold

The number of received Packet Measure ment Report message s on the receive level of the serving cell is measured continuou sly. When the statistical value is greater than or equal to the value of this parameter , the normal reselectio If the number of times when the receive level of the serving cell within "Normal Cell Reselecti on Watch Period" is lower than "Cell Reselecti on Level Threshold " is greater than the value of this parameter , the normal cell reselectio

GBFD116201

NetworkControlled Interval Cell Type Reselecti on (NC2)

1~32

GBFD116201

NetworkControlled Interval Cell Type Reselecti on (NC2)

1~32

This parameter specifies the number of the Number reserved Reserved SET of PDCHs DynPdch GCELLP GBFDReserved BSC6900 that are PreTranN SCHM(O 113101 Dynamic not used um ptional) Channel for channel converstio n in the dynamic transferab le channel This parameter specifies the number of idle channels that should be reserved on a cell after the TRX is shut Reserved down. TCH SET When the ReservedI Number GCELLO number of GBFDBSC6900 dleCh for PA THEXT(O idle 111602 Turning ptional) channels On on a cell is smaller than this threshold, the BSC6900 enables a TRX. This parameter is used to prevent the impact enabling or

PDCH Dynamic Interval Adjustme Type nt

0~8

TRX Power Interval Amplifier Type Intelligent Shutdown

0~16

BTS ResetAlm Reset DelaySwit Alarm ch Delay Switch

SET OTHSOF BSC6900 TPARA(O ptional)

BTS ResetAlm Reset DelayTim Alarm e Delay Time

SET OTHSOF BSC6900 TPARA(O ptional)

Reset SET Interval of RESETIN PWDPOL Account BSC6900 TERVAL ICY(Optio Lock nal) Counter

Whether to withhold link breakdow n alarms in case of BTS resets due to data If OML links break down after BTS resets caused by data configurat ions and recover within the period specified by this parameter , configurat ion reset alarms are reported; If OML links fail to recover within the period specified by this parameter , OML link Interval for resetting the counter when the user fails to log in Retry

GBFD111202

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

GBFD111202

O&M of BTS

Interval Type

0~65535

MRFD210305

Security Interval Managem Type ent

1~60

RESETR Reset ETRY Retry

times after the SET peer BSCNSP response GBFDBSC6900 ARA(Opti timer 114101 onal) expires during NSVC reset

GPRS

Interval Type

1~255

BTS RESETTI Reset ME Time

The waiting SET time from BTSOTH BTS GBFDBSC6900 PARA(Op detect 111612 tional) OML disconnec t to BTS Duration SET BSCNSP BSC6900 ARA(Opti onal) of the peer response GBFD114101 timer during NSVC reset

MultiCarrier Intelligent Interval Voltage Type Regulatio n

1~15

RESETTI Reset MER Timer

GPRS

Interval Type

1~120

RESID

Reason

TST SNDRSI( BSC6900 Mandator y)

Reason for activating GBFDthe radio 119001 status procedure

Gb Interface Function

Whether the HO RQD message s sent by the BSC to an MSC carry response request cells. Response Response SET request RespReq on OutOTHSOF cells are GBFDBSC6900 Sel BSC HO TPARA(O optional. 111804 Req ptional) They are used to inform the MSC whether it needs to return HO REJECT message s when HO RQD message s fail to trigger

MSLOST( RADIO_S TS_MS_L OST), QUALITY BAD(RAD IO_STS_ Enumerati QUALITY on Type _BAD), CELLRES ELECT(R ADIO_ST S_CELL_ RESELE CT)

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

REST

DLD Resume LICENSE Broken (Optional) BSC6900 Download ULD s Flag LICENSE (Optional)

Whether to resume broken download

GBFD111203 MRFD210403

O&M of BSC Enumerati NO(No), License on Type YES(Yes) Managem ent

Duration Subof the protocol ADD RESTAR PPP/MP negotiate BSC6900 PPPLNK( TTMR link out Optional) restart time[S] timer

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

2~5

Subprotocol ADD RESTAR negotiate BSC6900 MPLNK(O TTMR out ptional) time[S]

Duration of the PPP/MP link restart timer

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

2~5

Alarm RESTYP Restore E Type

EXP ALMLOG( Restoratio Optional) MRFDBSC6900 n type of STA 210304 the alarm ALMLOG( Optional) Time for the BSC to initiate the common ADD measure MRFDBSC6900 GNRNC( ment or 211402 Optional) informatio n exchange procedure after this procedure

Faulty Bit Field Managem Type ent

Noneed, Manually, Reset, Normally, Correlativ e, Configura tion, Expired

RESUME Resume TIMER Timer

MBSC Interval Load Type Balancing

0~86400

While assigning channels, the BSC ensures that the sum of the number of channels occupied by highpriority users and the SET number of Reserved GCELLC REVCHA GBFDidle Channel BSC6900 HMGBASI NNUM channels 116001 Number C(Optiona reserved l) for highpriority users is no smaller than this parameter . Every time the BSC assigns channels to a user whose priority is

Resource Interval Reservati Type on

0~190

Maximum number of levels that the BTS RF power decrease s. This parameter is used to control the decrease in the SET BTS RF Max RC RFMAXP GCELLO power. If MRFDPower BSC6900 WRDEC THEXT(O the value 210301 Reduction ptional) is too large, the BTS power decrease s too much. If the value is too small, the BTS power decrease s less and

Configura tion Interval Managem Type ent

0~21

Interval for sending the radio resource indication message s. The TRX reports the interferen ce level for each of the Radio SET channels RFRESIN Resource GCELLC that have BSC6900 DPRD Report CCH(Opti been idle Period onal) for the whole measure ment period. This parameter is used by a BTS to inform the BSC6900 of the interferen ce levels on idle channels

GBFD111004 GBFD111101

Radio Dedicated Channel Managem Interval ent Type System Informatio n Sending

0~255

RFT

Execute Interval

Interval for executing the scheduled subtask The unit is determine d according to the time mode. 1. If the time ADD mode is GBFDBSC6900 SUBTSK( 111203 set to Optional) "DAILY_T " or "DAILY_C ", the unit is day. 2. If the time mode is set to "WEEKLY _T" or "WEEKLY _C", the unit is week. 3. If the

O&M of BSC

Interval Type

1~100

1. This parameter specifies whether to configure the DRFU, MRFU, GRFU, or XRFU by slot or link. 2. When setting the BTS Configure ADD RFUCFG to support GBFDRFU by BSC6900 BTS(Opti BYSLOT 111202 the Slot onal) configurat ion of the RFU by slot, set this parameter to "YES". When setting the BTS not to support the configurat ion of the RFU by

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

RGPSIND GPS or ICATION RGPS

Satellite card protocol that is enabled to communi cate with the satellite card connectin g to the DGPS. If "RGPS" is SET specified, BTSDGP it GBFDBSC6900 SBP(Opti indicates 510401 onal) that the RGPS satellite card protocol is enabled to communi cate with the satellite card connectin g to the DGPS. If "GPS" is Whether to support RAN informatio n managem ent (RIM). IN the ADD GBFDRIM BSC6900 NSE(Opti procedure 116301 onal) , RANs(Ra dio Access Network) can exchange message

RGPS(R BTS GPS Enumerati GPS), Synchroni on Type GPS(GPS zation )

RIMSUP

RIM Support

Network Assisted Cell Change (NACC)

NO(No Enumerati Support), on Type YES(Sup port)

RLCN

Channel No.

The loopback channel number when the SET port BSC6900 E1T1LOP None loopback (Optional) mode is set to TDM remote loopback

None

Bit Field Type

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

RLT

Radio Link Timeout

Time for disconnec ting a call when the MS fails to decode the SACCH. Once a dedicated channel is assigned to the MS, the counter S SET is enabled GCELLC and the GBFDBSC6900 CBASIC( initial 111004 Optional) value is set to this parameter value. Each time an SACCH message is not decoded, the counter S decrease s by 1. Each time an

4_Times, 8_Times, 12_Times , 16_Times , 20_Times , 24_Times , 28_Times , Radio 32_Times Dedicated , Enumerati Channel 36_Times on Type Managem , ent 40_Times , 44_Times , 48_Times , 52_Times , 56_Times , 60_Times , 64_Times

Remote TC SET RMTTCA Subrack BSCBASI TERTRA Ater BSC6900 C(Optiona NSMODE Transmis l) sion Mode

RNCID

RNC ID

ADD GEXT3G BSC6900 CELL(Ma ndatory)

Transmis sion mode on the Ater interface of the remote TC subrack. The meaning of values is as follows: STANDA LONETC: not converge d MASTERI NPOOLT C: control subrack for TC converge nce SLAVEIN POOLTC: noncontrol RNC ID of a 3G external cell. The value of this parameter must be consistent with the data configurat ion at the RNC.

GBFD116902

STANDA LONETC( Stand Alone TC ), Ater MASTERI Compres Enumerati NPOOLT sion on Type C(Master Transmis in Pool sion TC), SLAVEIN POOLTC( Slave in Pool TC)

MRFD210301

Configura tion Interval Managem Type ent

0~4095

Internal index of a neighbori ng RNC. This parameter is set to 255 when the neighbori ng RNC that serves ADD Neighbori the 3G RNCINDE GEXT3G MRFDng RNC BSC6900 external X CELL(Opt 211402 Index neighbor ional) is not configure d. You can use the "LST GNRNC" command to check whether the neighbori ng RNC is configure ADD GNRNC( Mandator Internal Neighbori RNCINDE index of a MRFDy) ng RNC BSC6900 X neighbori 211402 ADD Index GIURGC ng RNC ONN(Man datory) Name of a neighbori ADD ng RNC. Neighbori RNCNAM GNRNC( The name MRFDng RNC BSC6900 E Mandator is used to 211402 Name y) uniquely identify a neighbori ng RNC. SET Root CERTFIL RootCert Certificate BSC6900 E(Optiona File Name l) Name of the root MRFDcertificate 210305 file

MBSC Interval Load Type Balancing

0~16,255

MBSC Interval Load Type Balancing

0~16

MBSC String Load Type Balancing

None

Security String Managem Type ent

None

ADD SGSNRO Identifies ROUTEN GBFDRoute No. BSC6900 UTEINFO a router O 118603 (Mandator uniquely y)

Gb over IP

Interval Type

1~100

ROUTEP Route ORTNO Port No.

ADD SGSNRO BSC6900 UTEINFO (Mandator y)

RPTDLV QIALLO WED

Report SET Downlink GCELLS BSC6900 VQI OFT(Opti Allowed onal)

Router port number. The setting of this parameter must be consistent with the setting at the SGSN Whether to allow the BTS to report the downlink voice quality index (VQI). The VQI is used to indicate voice quality. It is calculated on the basis of BER, FER, and frame

GBFD118603

Gb over IP

Interval Type

1~100

GBFD116801

Voice Quality Index (Uplink VQI)

DISABLE( Disable), ENABLE( Enumerati Enable), on Type UNSUPP ORT(Uns upport)

Cell SET Reselecti GCELLN RPTPERI on MR BSC6900 WCTRLM ODI Period in SRPARA( Packet Optional) Idle Mode

Cell reselectio n measure GBFDment 119107 report period in packet idle mode

0.48sec(0 .48sec), 0.96sec(0 .96sec), 1.92sec(1 .92sec), 3.84sec(3 Networkin .84sec), Enumerati g Control 7.68sec(7 on Type Mode .68sec), 15.36sec( 15.36sec) , 30.72sec( 30.72sec) , 61.44sec(

Cell Reselecti SET on MR GCELLN RPTPERI Period in BSC6900 WCTRLM ODT Packet SRPARA( Transfer Optional) Mode

Cell reselectio n measure ment report period in packet transmissi on mode

GBFD119107 GBFD114302

0.48sec(0 .48sec), 0.96sec(0 .96sec), 1.92sec(1 Networkin .92sec), g Control 3.84sec(3 Mode .84sec), Enumerati GSM/TD7.68sec(7 on Type SCDMA .68sec), Interopera 15.36sec( bility 15.36sec) , 30.72sec( 30.72sec) , 61.44sec(

Speed Decrease ADD reduction rate alarm IPLOGIC GBFDRPTTHD BSC6900 alarm report PORT(Op 118605 report threshold tional) threshold Whether to allow the BTS to report the voice quality index (VQI). If this parameter is set to Report, the BTS reports the VQI. SET The GCELLO BSC6900 GBFDBSC6900 THBASIC collects 116801 (Optional) the traffic statistics on a per VQI basis. There are 11 levels of speech quality. If the level is lower, the speech quality is better. The traffic

IP QOS

Interval Type

20~99

Report RPTVOIC Speech E Quality

Voice Quality Index (Uplink VQI)

NO(Not report), Enumerati YES(Rep on Type ort), NONE(No ne)

For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in several Filter SET consecuti Length for RQSIGNL GCELLH ve GBFDSDCCH BSC6900 EN OFITPEN measure 117501 REP_QU (Optional) ment ANT reports. This parameter indicates the number of enhanced measure ment reports received on signaling channels used to

Enhanced Measure Interval ment Type Report(E MR)

0~31

For the purpose of accurately reflecting the radio environm ent of a network, filtering is performe d on the measured values in several Filter SET consecuti Length for RQTRAF GCELLH ve GBFDTCH BSC6900 FLEN OFITPEN measure 117501 REP_QU (Optional) ment ANT reports. This parameter indicates the number of enhanced measure ment reports received on voice channels used to filter the

Enhanced Measure Interval ment Type Report(E MR)

0~31

RSCGRP Rscgrp N No.

ADD IPPATH( BSC6900 Mandator y)

Resource group GBFDnumber of 118605 the PATH

IP QOS

Interval Type

0~2047

The parameter indicates whether ADD the Resource RSCMNG RSCGRP resource Managem BSC6900 None MODE (Mandator group is ent Mode y) shared or is used by a specific telecom carrier.

None

Enumerati SHARE(S on Type HARE)

Resource managem ent mode. The logical port working in the SHARE mode can ADD Resource be shared RSCMNG IPLOGIC GBFDmanagem BSC6900 by MODE PORT(Op 118605 ent mode multiple tional) carriers. The logical port working in the EXCLUSI VE mode can be used by

IP QOS

SHARE, Enumerati EXCLUSI on Type VE

Timer for punishing the neighbori ng cells when handover SET failures RSCPEN RscPenalt GCELLH occur due ALTYTIM BSC6900 yTimer OFITPEN to ER (Optional) resourcerelated causes, such as resources being insufficien t

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

RSCPOF RSCP F Offset

This parameter adjusts "Min RSCP threshold" ADD to enable G3GNCE BSC6900 the LL(Option selection al) of 3G candidate cells based on cell priorities

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~63

This parameter determine s the layers of 3G neighbori ng cells. If the measured value of a RSCP ADD 3G RSCPTH Threshold GEXT3G BSC6900 neighbori RES for Layer CELL(Opt ng cell is of 3G Cell ional) lower than this threshold, the 3G neighbori ng cell is positioned at the bottom layer, that is, layer 4.

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~63

RSD RSDSRC alarm source

RSD SET alarm BSC6900 OPT(Opti None triggering onal) source

None

BASIS_O Enumerati F_B1, on Type BASIS_O F_B2

RSF RSFSRC alarm source

RSF SET alarm BSC6900 OPT(Opti None triggering onal) source

None

BASIS_O Enumerati F_B1, on Type BASIS_O F_B2 MINUS_5 2db(52db), MINUS_4 8db(48db), MINUS_4 4db(44db), MINUS_4 0db(40db), MINUS_3 6db(36db), MINUS_3 Enumerati 2db(on Type 32db), MINUS_2 8db(28db), MINUS_2 4db(24db), MINUS_2 0db(20db), MINUS_1 6db(16db), MINUS_1 2db(12db), MINUS_1

SET GCELLN GPRS RSLCTO CRESEL Reselecti BSC6900 FFER ECTPAR on Offset A(Optiona l)

Used for calculatin g C2. The MS with a large GBFDvalue can 114101 be assigned with high access priority.

GPRS

RSLDL

Average BTS RSL SET downAverage BTSBWP bandwidth GBFDBSC6900 DownARA(Man of RSL 111202 bandwidth datory) link in BTS.

O&M of BTS

Interval Type

0~64

RSLDSC RSL P DSCP

RSLPRI

RSL Priority

Differentia ted service code of the specified SET RSL BSCABIS BSC6900 service PRIMAP( priority Optional) SET BSCABIS BSC6900 PRIMAP( Optional)

GBFD111202

O&M of BTS

Interval Type

0~63

GBFD111202

O&M of BTS

Interval Type

0~7

RSLUL

Average BTS RSL SET upAverage BTSBWP bandwidth GBFDBSC6900 UpARA(Man of RSL 111202 bandwidth datory) link in BTS. SET Specified BSCABIS GBFDBSC6900 RSL Vlan PRIMAP( 111202 Id Optional) SET BTSLAPD BSC6900 WS(Optio nal) Size of the RSL LAPD window

O&M of BTS

Interval Type

0~64

RSLVLAN RSL ID VlanId

O&M of BTS

Interval Type

2~4094

RSLWS

RSL LAPD Window Size

GBFD118601

Abis over Interval IP Type

0~96

RSNDES

Lock Reason

Reason for locking the LCK configurat CMCTRL( MRFDBSC6900 ion and Mandator 210301 managem y) ent control rights

COMMIS SIONING( Commissi Configura oning), tion Enumerati UPGRAD Managem on Type E(Upgrad ent e), RESTOR E(Restore

Threshold of the level difference between a neighbori ng cell and the serving cell, based on which the BSC filters the Relative SET measured RSSThre Signal OTHSOF values in GBFDBSC6900 s Strength TPARA(O the 510901 Threshold ptional) measure ment reports and collects traffic statistics during automatic neighbori ng cell optimizati on and automatic frequency optimizati This is the descriptio n file for resetting UPD the board. RSTDES JTGCPLD MRFDReset file BSC6900 The reset FILE (Mandator 210401 file names y) of different boards are

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

0~127

BSC/RNC Software String Managem Type ent

None

RSTF

Name of the result file generated after the command is executed. If this parameter is not specified, the name of the result file RUN is Result BATCHFI automatic GBFDBSC6900 File Name LE(Option ally 111203 al) generated in the format of BATCH_ RST_YYY YMMDDH HNNSSm mm. The result file is located in the ftp directory in the main area of the OMU, and

O&M of BSC

String Type

None

Restart RSTFUN switch

Whether ADD to enable GBFDBSC6900 OPC(Opti the restart 111804 onal) function

A Interface Protocol Process

Enumerati OFF(OFF on Type ), ON(ON)

ADD BTSPPPL NK(Optio nal) ADD BTSMPL NK(Optio Restart RSTIME BSC6900 nal) Timer Timer IMP BTSPPPL NK(Optio nal) IMP BTSMPL NK(Optio Maximum number of Max SET TCH RSVCHM Channel GCELLC channels FORECN Num BSC6900 HMGBASI reserved UM Reserved C(Optiona for for EC l) emergenc y call users

GBFD118611

Abis IP over E1/T1

Interval Type

1~65535

GBFD110202

Emergenc y Call Interval Service Type (TS12)

0~190

SET Reserved TRANSP RSVDPA Paramete BSC6900 ATCHPA RA1 r1 RA(Optio nal)

Paramete r1 reserved None for future use.

None

Enumerati OFF(OFF on Type ), ON(ON)

SET Reserved TRANSP RSVDPA Paramete BSC6900 ATCHPA RA10 r 10 RA(Optio nal)

Paramete r 10 reserved None for future use.

None

Interval Type

0~429496 7295

SET Reserved TRANSP RSVDPA Paramete BSC6900 ATCHPA RA2 r2 RA(Optio nal)

Paramete r2 reserved None for future use.

None

Enumerati OFF(OFF on Type ), ON(ON)

SET Reserved TRANSP RSVDPA Paramete BSC6900 ATCHPA RA3 r3 RA(Optio nal)

Paramete r3 reserved None for future use.

None

Enumerati OFF(OFF on Type ), ON(ON)

SET Reserved TRANSP RSVDPA Paramete BSC6900 ATCHPA RA4 r4 RA(Optio nal)

Paramete r4 reserved None for future use.

None

Enumerati OFF(OFF on Type ), ON(ON)

SET Reserved TRANSP RSVDPA Paramete BSC6900 ATCHPA RA5 r5 RA(Optio nal)

Paramete r5 reserved None for future use.

None

Enumerati OFF(OFF on Type ), ON(ON)

SET Reserved TRANSP RSVDPA Paramete BSC6900 ATCHPA RA6 r6 RA(Optio nal)

Paramete r6 reserved None for future use.

None

Enumerati OFF(OFF on Type ), ON(ON)

SET Reserved TRANSP RSVDPA Paramete BSC6900 ATCHPA RA7 r7 RA(Optio nal)

Paramete r7 reserved None for future use.

None

Interval Type

0~429496 7295

SET Reserved TRANSP RSVDPA Paramete BSC6900 ATCHPA RA8 r8 RA(Optio nal)

Paramete r8 reserved None for future use.

None

Interval Type

0~429496 7295

SET Reserved TRANSP RSVDPA Paramete BSC6900 ATCHPA RA9 r9 RA(Optio nal)

Paramete r9 reserved None for future use.

None

Interval Type

0~429496 7295

Reserve RsvIdleC Idle hanNum Channel Number

Number of reserved idle channels. If this parameter is set too small, the SET TRX may BSCDST be GBFDBSC6900 PA(Optio frequently 111602 nal) enabled/d isabled; if this parameter is set too large, idle TRX will not be timely closed.

TRX Power Interval Amplifier Type Intelligent Shutdown

0~3

RT

Recovery SET mode of Revertive GBFDBSC6900 MSP(Opti the MSP type 111701 onal) protection group

NONREVERTI VE(NONBoard Enumerati REVERTI Switchove on Type VE), r REVERTI VE(REVE RTIVE)

RTCONT Routing EXT Context

Routing context. The routing context identifies ADD a M3LE(Opt specified ional) route. If BSC6900 ADD the M3DE(Op routing tional) context is to be configure d, its value must be negotiate Ratio of

GBFD118602 GBFD118622

A over IP Interval A IP over Type E1/T1

0~429496 7295

the RTCP path bandwidth to the A interface bandwidth . According to the Real-time Transport Control Protocol (RTCP), ADD the RTCP RTCPBW GCNNOD BSC6900 GBFDBandwidt BSC6900 RATIO E(Optiona and the 118602 h Usage l) MSC negotiate the bandwidth occupatio n rate of the user plane on the A interface, that is, the bandwidth occupied by the data

A over IP

Interval Type

1~5

RTCPSW Enable ITCH RTCP

Whether to enable the realtime transport control protocol (RTCP) function. The BSC6900 and the MSC negotiate whether ADD and how GCNNOD to GBFDBSC6900 E(Optiona compress 118602 l) the data over the A interface according to the RTCP. The setting of this parameter on the BSC6900 side must be consistent with that

OFF(Clos Enumerati e), A over IP on Type ON(Open )

ADD Destinatio Destinatio OMUIPR RTDEST n Network BSC6900 n IP None T(Mandat Address address ory)

None

IP Address Type

None

ADD Destinatio RTDEST OMUIPR Routing n Address BSC6900 MASK T(Mandat mask Mask ory) ADD BTSIPRT( Optional) BSC6900 IMP BTSIPRT( Mandator y)

None

None

IP Address Type

None

RTIDX

Route Index

Index of a route. The GBFDindex is 118601 unique in a BTS.

Abis over Interval IP Type

0~15

It is used to calculate the roundtrip time of the protocol stack and the RTO value. The value must be ADD smaller RTO RTOALP SCTPLN than alpha BSC6900 HA K(Optiona "RTOBET value l) A". In the case of the fixed value of the "RTOBET A", the larger the value is, the less the link delay sensitivity It is used to calculate the roundtrip time of the protocol stack and the RTO value. The value must be ADD greater RTOBET RTO beta SCTPLN than BSC6900 A value K(Optiona "RTOALP l) HA". In the case of the fixed value of the "RTOALP HA", the larger the value is, the less the link delay

GBFD118602

A over IP

Interval Type

0~100

GBFD118602

A over IP

Interval Type

0~100

When the "RTOMIN " and "RTPMAX " parameter ADD RTO s are set SCTPLN RTOINIT initial BSC6900 to fixed K(Optiona value values, l) the larger the value is, the longer the check of the link is. When the "RTOMIN " parameter ADD is set to a RTO max SCTPLN fixed RTOMAX BSC6900 value K(Optiona value, the l) larger the value is, the longer the check of the link When the

GBFD118602

A over IP

Interval Type

500~6000 0

GBFD118602

A over IP

Interval Type

500~6000 0

RTOMIN

"RTOMA X" parameter ADD is set to a RTO min SCTPLN fixed GBFDBSC6900 value K(Optiona value, the 118602 l) larger the value is, the longer the check of the link Whether to measure the delay on the link SET between GCELLB the BTSs GBFDBSC6900 ASICPAR that serve 115506 A(Optiona the calling l) MS and the called MS respective ly

A over IP

Interval Type

500~6000 0

Measure RTPSWIT Link CH Delay Switch

AMR Coding DISABLE( Rate Enumerati Disable), Threshold on Type ENABLE( Adaptive Enable) Adjustme nt

Maximum number of RTTI TBFs that can be multiplexe d on the PDCH. A PDCH can be assigned when the number of RTTI TBFs on it RTTIPDC RTTI SET is smaller HMULTIP PDCH GCELLP than the BSC6900 LEXTHR Multiplex SCHM(O value of ESH Threshold ptional) this parameter . This parameter is valid only when its value is smaller than or equal to "MSRD PDCH DL Multiplexi ng Threshold ".

GBFD510805 GBFD119901 GBFD119902 GBFD119905 GBFD119906 GBFD111003 GBFD510805 GBFD119901 GBFD119902 GBFD119905 GBFD119906 GBFD111003

Latency Reduction Streaming QoS(GBR ) QoS ARP&TH P PoC QoS Conversat ional QoS Radio Common Channel Managem ent Interval Latency Type Reduction Streaming QoS(GBR ) QoS ARP&TH P PoC QoS Conversat ional QoS Radio Common Channel Managem ent

10~80

RTTYPE

Route Type

ADD BTSIPRT( Mandator y) BSC6900 IMP BTSIPRT( Mandator y)

RUS

Rate up step [kbps]

ADD IPLOGIC BSC6900 PORT(Op tional)

Type of the route. When the BTS does not support IP over E1, the parameter Route Type needs to be set to NEXTHO P(Next Hop). When the BTS supports IP over E1, the parameter Route Type needs to be set to OUTIF(O ut Interface) because the packets at the data link layer Logical port speed increase step. When detecting the available bandwidth increase through IPPM, the system increases the bandwidth of the logical port by using this parameter

GBFD118601

NEXTHO P(Next Abis over Enumerati Hop), IP on Type OUTIF(O ut Interface)

GBFD118605

IP QOS

Interval Type

0~1000

Rate up step RUSPRD adjust period [PLPRD]

Bandwidt h increase step adjustme nt period. This parameter indicates the period to increase the bandwidth ADD of the IPLOGIC GBFDBSC6900 logical PORT(Op 118605 port. Note tional) that the actual bandwidth increase step adjustme nt period is the packet drop ratio Statistics period multiplied by this R-version number of GBFDthe BTS 111202 software

IP QOS

Interval Type

1~100

RVer

SET BTSAUT R-Version BSC6900 ODLDAC No. TINFO(M andatory)

O&M of BTS

Interval Type

0~999

RXBW

ADD Backward Receive IPPATH( GBFDBandwidt BSC6900 bandwidth Mandator 118605 h of IP path y)

IP QOS

Interval Type

1~300000 0

RxBw

ADD Backward RSCGRP Receive GBFDBandwidt BSC6900 (Mandator bandwidth 118605 h y)

IP QOS

Interval Type

0~400000 0

RXLEVA CCMIN

Minimum receiving SET Minimum power GCELLS Receiving level for GBFDBSC6900 ERVPAR level for the MS in 114101 A(Optiona Access the cell to l) access the

GPRS

Interval Type

0~63

For AMR FR voice services, a fixed amount of offset is added to the correspon Interfere ding SET HO Qual. grade of RXLEVO GCELLA Thresh BSC6900 the FF MRQUL( Offset for received Optional) AMR FR signal quality for the interferen ce handover of nonAMR FR voice services.

GBFD115501 GBFD510501 GBFD110601

AMR FR HUAWEI II Interval Handover Type HUAWEI I Handover

0~70

RXMIN

Minum Access RXLEV

Minimum received signal level of the MS. This level is reported in the system informatio n. This parameter specifies the SET minimum GCELLB GBFDreceive BSC6900 ASICPAR level of an 111101 A(Optiona MS to l) access the BSS. For details. see GSM Rec. 05.08. The value of this parameter ranges from 0 to 63 (correspo nding to -

System Interval Informatio Type n Sending

0~63

Whether to use the emergenc y handover algorithm in case SET RXQCKF Rx_Level the GCELLH ALLHOE _Drop HO BSC6900 receive OBASIC( N Allowed level of Optional) the MSs drops rapidly, thus preventin g call drops.

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 1 BSC6900 1 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 10 BSC6900 10 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate. Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 11 BSC6900 11 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate. Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 12 BSC6900 12 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 2 BSC6900 2 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate. Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 3 BSC6900 3 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate. Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 4 BSC6900 4 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 5 BSC6900 5 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate. Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 6 BSC6900 6 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate. Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 7 BSC6900 7 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 8 BSC6900 8 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate. Threshold for the interferen ce handover Interfere SET of NonHO Qual. RXQUAL GCELLA AMR FR Thresh 9 BSC6900 9 MRQUL( voice for NonOptional) services. AMR FR AMRFR refers to Adaptive Multi-Rate Full Rate. ADD TRXBIND RXUCHAI RXU BSC6900 2PHYBR NNO Chain No D(Mandat ory)

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

Number of the RXU GBFDchain to 111202 which the RXU belongs Number

O&M of BTS

Interval Type

0~249

of the RXU chain. The RXU chain No. is unique in one Number of the ADD RXU RXUCHAI RXU BTSRXU BSC6900 chain NNO Chain No. BRD(Man where the datory) board is located SET RXUCHAI RXU BTSRXU BSC6900 NNO Chain No. BP(Mand atory)

GBFD111202

O&M of BTS

Interval Type

0~249

GBFD111202

O&M of BTS

Interval Type

0~249

RXU RXUIDTY Index PE Type

ADD TRXBIND Index type GBFDBSC6900 2PHYBR of the 111202 D(Mandat RXU ory)

O&M of BTS

RXU RXUIDTY Index PE Type

SET BTSRXU BSC6900 BP(Mand atory)

Type of the RXU board index

GBFD111202

O&M of BTS

RXUNAM RXU E Name

RXUNAM RXU E Name

ADD TRXBIND Name of BSC6900 2PHYBR the RXU D(Mandat ory) Name of the RXU SET board. BTSRXU BSC6900 The RXU BP(Mand name is atory) unique in one BTS. ADD BTSRXU Name of BSC6900 BRD(Man an RXU datory) Position number of the RXU on the RXU chain Position SET No. of the BTSRXU RXU BSC6900 BP(Mand board on atory) the RXU chain ADD TRXBIND BSC6900 2PHYBR D(Mandat ory)

RXUNAM E(By RXU Name), RXUPOS( Enumerati By RXU on Type Position No), SRNSN(B y Subrack No) RXUNAM E(RXUNa me), Enumerati RXUPOS( on Type RXUPOS) , SRNSN(S RNSN) String Type None

GBFD111202

O&M of BTS

GBFD111202

O&M of BTS

String Type

None

RXUNAM RXU E Name

GBFD111202

O&M of BTS

String Type

None

RXU RXUPOS Chain Position

GBFD111202

O&M of BTS

Interval Type

1~6

RXU RXUPOS Chain Position

GBFD111202

O&M of BTS

Interval Type

1~6

RXU RXUPOS Board Position

ADD BTSRXU BSC6900 BRD(Man datory)

Position of the RXU GBFDboard on 111202 an RXU chain

O&M of BTS

Interval Type

1~6

RXU RXUTYP Board E Type

SET Type of BTSRXU BSC6900 the RXU BP(Mand board atory)

GBFD111202

O&M of BTS

DRRU(D RRU), DRFU(DR FU), MRRU(M RRU), MRFU(M Enumerati RFU), on Type GRFU(G RFU), GRRU(G RRU), BTS3900 E(BTS39 00E)

S1 value S1SWITC setting H switch

Whether to enable the switch to set the S1 value. S1 byte, also SET called the BSC6900 OPT(Opti synchroni None onal) zation status byte, is one of the optical connectio n parameter

None

Enumerati OFF(OFF on Type ), ON(ON)

S1 sending value. It is a synchroni zation status byte used by the local end to examine the quality of the SET received S1VALUE S1 Value BSC6900 OPT(Opti clock onal) signals before the local end switches to a clock source with higher quality. The smaller the value of S1 is, the lower Whether to enable the special analog alarm. In multimode scenario, the value Special SET of this Analog BTSDEM SAADIS BSC6900 parameter Alarm UBP(Opti in one Enabled onal) mode must be the same as the value of the correspon ding parameter in another

None

None

Interval Type

0~15

GBFD112301 MRFD210304

Remote EAC Maintena Bit Field nce Type Faulty Managem ent

48VDISA BLE, RES0, RES1, RES2, TSDISAB LED, HSDISAB LED, RES3, RES4

SAAF

Special Analog Alarm Flag

The value of this parameter consists of 32 bits, each of which determine s whether to enable the correspon ding special analog SET alarm. "0" BTSAPM indicates GBFDBSC6900 UBP(Opti that the 111202 onal) alarm is enabled, and "1" indicates that the alarm is disabled. When an item is selected, the correspon ding analog alarm switch is

O&M of BTS

Bit Field Type

BT1_DIS ABLE, AH_DISA BLE, AT1_DIS ABLE, AT2_DIS ABLE, BT2_DIS ABLE

SaGsmrM Trunking sc MSC

Whether the MSC independ ently processe s the trunking services. When this parameter is set to YES, the ADD MSC GCNNOD GBFDBSC6900 independ E(Optiona 510301 ently l) processe s the trunking services, that is, the trunking services are processe d only by this MSC.

Public Voice Group Call Service

Enumerati NO(No), on Type YES(Yes)

SAICALL SAIC OWED Allowed

Whether an MS supports the SAIC function. Single Antenna Interferen ce Cancellati on (SAIC) is used to reduce the impact of SET interferen GCELLP ce on the GBFDBSC6900 WRBASI reception 118103 C(Optiona of l) downlink signals through a signal processin g technolog y. An MS enabled with SAIC has improved ability of antiinterferen

Network Support SAIC

Enumerati NO(No), on Type YES(Yes)

Adjustme nt step of the downlink signal quality threshold in power control algorithm II for MSs that support SAIC. The Power SET network SAICTHR Control GCELLP side uses GBFDEDAPDT Threshold BSC6900 WR2(Opti a lower 118103 VALUE Adjust for onal) downlink SAIC signal quality threshold for SAICsupported MSs in power control, thus lowering the transmit power of the correspon

Network Support SAIC

Interval Type

0~2

Adjustme nt step of the downlink signal quality threshold in power control algorithm III for MSs that support SAIC. The Power SET network SAICTHR Control GCELLP side uses GBFDEDAPDT threshold BSC6900 WR3(Opti a lower 118103 VALUE Adjust for onal) downlink SAIC signal quality threshold for SAICsupported MSs in power control, thus lowering the transmit power of the correspon

Network Support SAIC

Interval Type

0~4

SALOG

Special Analog Alarm Enabled

The value of this parameter consists of five bits, which determine s whether to enable the alarms. "0" indicates that the SET analog BTSDPM alarm is MRFDBSC6900 UBP(Opti enabled, 210304 onal) and "1" indicates that the analog alarm is disabled. In multimode scenario, the value of this parameter in one mode must be the same Index of a cell with the same GBFDcoverage 111610 as the current cell

Faulty Bit Field Managem Type ent

T1_DISA BLE, ET_DISA BLE, ET1_DIS ABLE, ET2_DIS ABLE, T2_DISA BLE

SET Same GCELLD SAMECV Coverage BSC6900 YNTURN GCELLID Cell No OFF(Man datory)

Dynamic Interval Cell Type Power Off

0~2047

Index type SET Same used SAMECV GCELLD Coverage when the GBFDGCELLID BSC6900 YNTURN Cell Index command 111610 TYPE OFF(Man Type is datory) executed

BYNAME( Dynamic Enumerati By name), Cell on Type BYID(By Power Off index)

The BSC6900 checks the load of the same coverage cell of the target cell once a minute. When the number of SET times in SAMECV Same GCELLD which the GCELLL Coverage GBFDBSC6900 YNTURN load of OADSTA Cell Load 111610 OFF(Opti the same TTM Stat. Time onal) coverage cell is lower than "Same Coverage Cell Load Threshold " is equal to the value of this parameter , the A cell that can be disabled is allowed to be disabled SET only when SAMECV Same GCELLD the load GCELLL Coverage GBFDBSC6900 YNTURN of the OADTHR Cell Load 111610 OFF(Opti same D Threshold onal) coverage cell is lower than this threshold for a period.

Dynamic Interval Cell Type Power Off

1~16

Dynamic Interval Cell Type Power Off

0~100

SET Same SAMECV GCELLD Coverage GCELLN BSC6900 YNTURN Cell AME OFF(Man Name datory)

Name of the same GBFDcoverage 111610 cell

Dynamic String Cell Type Power Off

None

SACCH SAMULF MultiRM Frames

This parameter is used by the BTS to inform the BSC6900 of radio link connectio n failure. When the BTS receives the SET SACCH GCELLC measure GBFDBSC6900 CBASIC( ment 111004 Optional) report from the MS, the counter for determini ng whether a radio link is faulty is set to the value of this parameter . Each time the

Radio Dedicated Interval Channel Type Managem ent

0~63

SAS

Special Alarm Switcher

SET BTSDPM BSC6900 UBP(Opti onal)

SASE

Special Alarm Switch Enabled

SET BTSDEM BSC6900 UBP(Opti onal)

The value of this parameter consists of three bits, which determine s whether to enable the alarms. "0" indicates that the alarm is enabled, and "1" indicates that the alarm is disabled. In multimode scenario, the value of this parameter in one mode must be the same as the value of Whether to enable the special alarm switch. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another

MRFD210304

Faulty Bit Field Managem Type ent

WATER_I MMERSE D, SMOG, GM_DISA BLE

GBFD112301 MRFD210304

Remote EAC Maintena Bit Field nce Type Faulty Managem ent

WIDISAB LE, SMDISAB LE, IMDISAB LE, GMDISAB LE

SASV

Level specificati ons of special Boolean value alarms. Two specificati ons are available: high level and low level. By default, Special SET only Alarm BTSDEM alarms of Switch BSC6900 UBP(Opti the door Valid Vol. onal) status Level sensor are low level, and alarms of the water sensor, smoke sensor, and infrared sensor are high level. In multimode Whether

GBFD112301 MRFD210304

Remote EAC Maintena Bit Field nce Type Faulty Managem ent

WILOW, SMLOW, IMLOW, GMLOW

Energy SAVEEN Saving ABLED Support

to enable the SET energy BTSDOM saving GBFDBSC6900 UBP(Opti function 111202 onal) of the TRX for the BTS3002

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

SBAF

Special Bool Alarm Flag

SET BTSAPM BSC6900 UBP(Opti onal)

SBTSID

COL First BTS SYNCINF BSC6900 Index O(Mandat ory)

Whether to enable the special Boolean alarms, that is, water sensor alarm (bit 0), smog sensor alarm (bit 1), and door sensor alarm (bit 2). All the Boolean alarms are enabled by default. "0" indicates that the alarm is enabled, and "1" indicates that the alarm is disabled. Number of the BTS. The BTS is numbered uniquely in a BSC.

GBFD111202

O&M of BTS

Bit Field Type

WS_DISA BLE, SS_DISA BLE, GS_DISA BLE

GBFD118201

SoftSynchroni Interval zed Type Network

0~2047

COL SBTSNA First BTS SYNCINF BSC6900 ME Name O(Mandat ory)

Name of the BTS. The BTS GBFDis named 118201 uniquely in a BSC.

SoftSynchroni String zed Type Network

None

SCALEO SCALE_ RDER ORDER

SET GCELLC BSC6900 CUTRAN SYS(Opti onal)

SET DSCP of BSCPST SCDSCP STREAM[ BSC6900 CDSCPM QoS] AP(Optio nal)

This parameter indicates that when the MS reports the EMR, it adds the value of this parameter to the received signal level, and then converts the result into the RXLEV value. For details, see GSM Rec. 05.08. If the SCALE_ Order reported by the MS is 10 dBm, level values 0DSCP correspon ding to the streaming service

GBFD117501

ADD0dB( Enhanced +0dB), Measure ADD10dB Enumerati ment (+10dB), on Type Report(E Automatic MR) (Automati c)

GBFD118603

Gb over IP

Interval Type

0~63

Serving SET Cell Filter SCELLFI GCELLH Length BSC6900 LTER OFAST(O MR ptional) Number

First Cell SCELLID Index

ADD NCELL(M andatory) BSC6900 COL SYNCINF O(Mandat ory)

When the network receives measure ment reports, in considera tion of the accuracy of a single measure ment report, the measure ment values in certain measure ment reports are filtered to represent the radio operating environm ent. The parameter specifies the number of measure ment reports Number of the cell where the TRX reside. The cell is numbered uniquely in a BSC.

GBFD510102

Fast Interval Move Type Handover

1~20

MRFD210301

Configura tion Interval Managem Type ent

0~2047

SCELLNA First Cell ME Name

ADD NCELL(M andatory) Name of BSC6900 COL cell 1 SYNCINF O(Mandat ory)

GBFD111202

O&M of BTS

String Type

None

SCHEME

Coding Scheme

A key parameter SET that GCELLS indicates BC(Optio the nal) coding GBFDBSC6900 ADD scheme 113602 GSMSCB of a (Mandator simple y) cell broadcast message

GERMAN (GERMA N), ENGLISH (ENGLIS H), ITALIAN(I TALIAN), FRENCH( FRENCH) , SPANISH (SPANIS H), DUTCH(D UTCH), Simplified Enumerati SWEDIS Cell on Type H(SWEDI Broadcast SH), DANISH( DANISH), PORTUG UESE(PO RTUGUE SE), FINNISH( FINNISH) , NORWE GIAN(NO RWEGIA N), GREEK( GREEK),

Sub SCHNNO Channel No.

STR Number GBFDBSC6900 BTSTST( of the sub111202 Optional) channel

O&M of BTS

Interval Type

0~1

SCMD

ADD SUBTSK( Mandator Comman y) BSC6900 d String ADD SUBCMD (Mandator y)

SCOPET Scope YPE Type

SET GMRSCO BSC6900 PE(Mand atory)

SCPIDX

Subrack ADD Communi SRCONP cation BSC6900 ATH(Opti Path onal) Index

Comman d string of the scheduled subtask. This command can be only a service command , and the system command cannot be added to the scheduled subtask. Type of querying used to set the measure ment report collection scope. Indicates the index of the intersubrack connectio n path

GBFD111203

O&M of BSC

Any Type None

GBFD111203

O&M of BSC

BYBTSID( By BTS Enumerati ID), on Type BYCELLI D(By Cell ID)

GBFD111203

O&M of BSC

Interval Type

0~23

ADD GEXT3G Scramblin CELL(Ma g Code or ndatory) SCRAMB Cell BSC6900 SET LE Paramete GCELLH r Id OFDDBA 2(Mandat ory)

Scramblin g code of a 3G cell. The scramblin g code is used to differentia te terminals or cells. It is used after spread spectrum. Therefore , it does not change the bandwidth of signals, but only distinguis hes the signals from different sources. Through scramblin g, multiple transceive rs can

GBFD114301 GBFD114302

GSM/WC DMA Interopera bility Interval GSM/TD- Type SCDMA Interopera bility

0~511

SCSN

EXP ALMLOG( Start Optional) BSC6900 Serial No. STA ALMLOG( Optional)

Start serial MRFDnumber of 210304 the alarm record

Faulty Interval Managem Type ent

1~214748 3646

SCTPLN KN

SCTP link number of ADD XPU SCTPLN board. K(Mandat SCTP link This BSC6900 ory) No. number ADD identifies M3LNK(M an SCTP andatory) link uniquely.

GBFD118602 GBFD118622

A over IP Interval A IP over Type E1/T1

0~1199

SD

Date ADD when the SUBTSK( GBFDStart Date BSC6900 scheduled Mandator 111203 task is y) started

O&M of BSC

year, Compoun month, d Type date

SD

Start date of the alarm EXP record. By MRFDStart Date BSC6900 ALMLOG( default, 210304 Optional) the start date is 2000-0101. date Start of the alarm STA record. By MRFDStart Date BSC6900 ALMLOG( default, 210304 Optional) the start date is 2000-0101. SET Alarm Log ALMCAP Saved BSC6900 ACITY(Op Time tional) Maximum number of days for MRFDstoring 210304 history alarms

Faulty year, Compoun Managem month, d Type ent day

SD

Faulty year, Compoun Managem month, d Type ent day

SD

Faulty Interval Managem Type ent

7~90

SET SD alarm SDALMT SD Alarm GBFDBSC6900 MSP(Opti triggering HD Threshold 111701 onal) threshold

1E-3, 1EBoard 4, 1E-5, Enumerati Switchove 1E-6, 1Eon Type r 7, 1E-8, 1E-9

SDATE

STR GBFDStart Date BSC6900 BTSLOG( Start date 111202 Optional)

O&M of BTS

year, Compoun month, d Type day

SDAY

Start date of the SET daylight Start date BSC6900 TZ(Mand saving atory) time (DST)

GBFD116101 MRFD210301

Support of Daylight Saving Interval Time Type Configura tion Managem ent

1~31

Number of SDCCH channels. Rules for SDCCH channel allocation: 1. Allocate channels 1 and 3 of main frequency B ADD preferenti SDCCHC GCELLQ SDCCHN MRFDally. 2. hannelNu BSC6900 UICKSET UM Allocate 210301 mber UP(Optio channels nal) 1, 3, 5, and 7 according to the physical position order of the frequenci es. Thus, the maximum number of SDCCH channels

Configura tion Interval Managem Type ent

1~191

Whether a call must camp on the SDCCH Waiting SET for a SDCCHW for MR on GCELLH GBFDBSC6900 specific aitMREn SDCCH OAD(Opti 110502 duration Switch onal) before being assigned with a traffic channel.

Assignme nt and Immediat Enumerati OFF(Off), e on Type ON(On) Assignme nt

Duration SDCCHW for aitMRTim Waiting eLen MR on SDCCH

Duration for a call camping on the SET SDCCH GCELLH GBFDBSC6900 before OAD(Opti 110502 being onal) assigned with a traffic channel.

Assignme nt and Immediat Interval e Type Assignme nt

0~100

Level threshold for measurin g the number of call drops on SDCCH. When call drop occurs on the SDCCH, the DL Level SET BSC6900 SDDROP Threshold GCELLO determine GBFDSTATDLL for BSC6900 THEXT(O s whether 111004 EV SDCCH ptional) the Call Drop downlink receive level is lower than this threshold. If the downlink receive level is lower than this threshold and the TA is

Radio Dedicated Interval Channel Type Managem ent

0~63

Quality threshold for measurin g the number of call drops on SDCCH. When call drop occurs on the SDCCH, DL the Quality SET BSC6900 SDDROP Threshold GCELLO determine GBFDSTATDL BSC6900 for THEXT(O s whether 111004 QUAL SDCCH ptional) the Call Drop downlink quality level multiplied by 10 is higher than this threshold. If all the following four conditions are met, the number of

Radio Dedicated Interval Channel Type Managem ent

0~70

Level threshold for measurin g the number of call drops on SDCCH. When call drop occurs on the SDCCH, the UL Level SET BSC6900 SDDROP Threshold GCELLO determine GBFDSTATULL for BSC6900 THEXT(O s whether 111004 EV SDCCH ptional) the uplink Call Drop receive level is lower than this threshold. If the uplink receive level is lower than this threshold and the TA is smaller

Radio Dedicated Interval Channel Type Managem ent

0~63

Quality threshold for measurin g the number of call drops on SDCCH. When call drop occurs on the SDCCH, UL the Quality SET BSC6900 SDDROP Threshold GCELLO determine GBFDSTATUL BSC6900 for THEXT(O s whether 111004 QUAL SDCCH ptional) the uplink Call Drop quality level multiplied by 10 is higher than this threshold. If all the following four conditions are met, the number of call drops

Radio Dedicated Interval Channel Type Managem ent

0~70

SDDYN

Whether to allow SDCCH dynamic allocation, SET SDCCH that is, GCELLB Dynamic whether GBFDBSC6900 ASICPAR Allocation to allow 113001 A(Optiona Allowed dynamic l) conversio n between TCHs and SDCCHs.

SDCCH Dynamic Enumerati NO(No), Adjustme on Type YES(Yes) nt

SDENAB SD LE Enable

SET Enable BSC6900 MSP(Opti SD onal)

GBFD111701

Board Enumerati DISABLE, Switchove on Type ENABLE r

Whether to enable the SDCCH quick handover test function. If this parameter is set to Yes, the BSC6900 initiates intra-cell SET SDCCH SDFAST SD Quick GCELLS handover GBFDHOSWIT BSC6900 HO OFT(Opti as soon 113503 CH onal) as the MSC issues an encrypted command to the MS. Thus, the forwardin g encrypted signaling can be transmitte d and received on a new

A5/3 Enumerati OFF(Off), Ciphering on Type ON(On) Algorithm

Shut SDFLAG Down Enabled

This parameter specifies whether the BSC6900 automatic ally shuts down the SET power GTRXDE amplifier GBFDBSC6900 V(Optiona of the 111605 l) TRX to save power when the BTS is powered by batteries after a power

Active Backup Power Control

DISABLE( Enumerati Disable), on Type ENABLE( Enable)

Min Interval SDHOMI for NINTV SDCCH Hos

After a new SDCCH is assigned to an MS, the MS can be handed over to another channel SET only if the GCELLH time BSC6900 OCTRL(O during ptional) which the MS occupies the SDCCH is longer than the period specified by this parameter .

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~60

SDMRCU SdMrCut TNUM Num

Maximum number of discarded MRs SET allowed GCELLP GBFDBSC6900 on the WR3(Opti 117601 SDCCH onal) in a power control period Period in which level penalty is performe d on the neighbori ng cells of the cell where a fastmoving ADD MS is GEXT2G BSC6900 located. CELL(Opt The ional) neighbori ng cells must be located at the Macro, Micro, or Pico layer other than the Umbrella layer.

HUAWEI III Power Interval Control Type Algorithm

0~5

Penalty Time on SDPUNTI Fast ME Moving HO

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

Penalty SDPUNV on Fast AL Moving HO

Level value of the penalty that is performe d on the neighbori ng cells of the cell where a fastADD moving GEXT2G MS is BSC6900 CELL(Opt located. ional) The neighbori ng cells must be located at the Macro, Micro, or Pico layer other than the Umbrella layer.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

SDSCP

SET BSCPST DSCP of BSC6900 CDSCPM Signaling AP(Optio nal)

DSCP correspon GBFDding to 118603 the signaling

Gb over IP

Interval Type

0~63

SDSF SDSFPRI Priority

Specifies SET the SF GBFDBSC6900 MSP(Opti and SD 111701 onal) event priority

HIGH(HI Board Enumerati GH), Switchove on Type LOW(LO r W)

SDT

SET Shutdown BTSAPM Temperat BSC6900 UBP(Opti ure onal)

Sliding ADD Time BTSALM SDTMWD Window BSC6900 MGMRUL ALMDIS Alarm E(Mandat Disappear ory)

High temperatu re threshold for triggering power shutdown of the battery. If the power shutdown upon battery high temperatu re is enabled and the battery temperatu re is higher than the value of this parameter , the battery is automatic ally powered off. In multiSliding time window for collecting statistics on the alarms that disappear in a specified period of time.Sam pling time window. In the period specified by this parameter , the duration in which the alarm persists is

GBFD111202 GBFD111601

O&M of BTS BTS Interval Power Type Managem ent

40~70

MRFD210304

Faulty Interval Managem Type ent

0~65535

Sliding time window for collecting statistics on the alarms that occur in a specified period of Sliding ADD time.This Time BTSALM parameter SDTMWD Window MRFDBSC6900 MGMRUL is similar ALMOC Alarm 210304 E(Mandat to the Occurren ory) sampling ce time window. In the period specified by this parameter , the duration in which the alarm persists is

Faulty Interval Managem Type ent

0~65535

SDV

SET Shutdown BTSAPM BSC6900 Voltage UBP(Opti onal)

3G SEARCH Search 3G PRIO

SET GCELLC BSC6900 CUTRAN SYS(Opti onal)

Low voltage threshold for triggering power shutdown of the battery. If the power shutdown upon low voltage is enabled and the load voltage is lower than the value of this parameter , the battery is automatic ally powered off. In multimode scenario, the value of this parameter Whether to allow the MS to search for a 3G cell when the BSIC must be decoded

GBFD111202

O&M of BTS

Interval Type

350~556

GBFD117501

Enhanced Measure Enumerati NO(No), ment on Type YES(Yes) Report(E MR)

SELFVER Self SION Version

SET Self BTSLOA BSC6900 Software DCTRL(M Version andatory)

GBFD111202

O&M of BTS

String Type

None

This parameter specifies whether Support SET the SI Send2Qut Sent OTHSOF Type 3 GBFDBSC6900 erFlag 2QUATE TPARA(O message 111101 R ptional) contains the 2QUATE R indicator.

System Enumerati NO(No), Informatio on Type YES(Yes) n Sending

Whether to report BSS INVOKE TRACE message. When the parameter is set to YES, the BSC sends a BSS INVOKE Spt BSS TRACE Invoke SET message SendBssI Trace OTHSOF to the GBFDnvokeTra BSC6900 Rpt[end2 TPARA(M MSC if 116401 ce end user andatory) receiving trace] an MSC INVOKE TRACE or BSS INVOKE TRACE message from MSC in the case of an outgoing BSC handover. If the BSC Whether to report Send the Classmar SET SENDCM classmark k ENQ GCELLS AFTERIN BSC6900 queried Result to OFT(Opti BSCHO by the MSC onal) BSC6900 Enabled to the MSC GBFD110601 GBFD510501

End-toEnd MS Enumerati NO(No), Signaling on Type YES(Yes) Tracing

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

Sent SET SendConf Confusion AITFOTH usionToM BSC6900 Message PARA(Op SC to MSC tional)

Send SENDDO Downlink SET WNLINK Message OTHSOF BSC6900 MESSAG after TPARA(O E Hanging ptional) up

Whether to send a CONFUSI ON message to the MSC. This parameter specifies whether to send a message carrying fault location informatio n to the MSC if the BSC receives a message that cannot be decoded over the A interface. If this parameter is set to No, the BSC responds with an SAPI N'Reject message against the DL short message after hangup.

GBFD111804

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

GBFD110203

Point To Point Short Enumerati NO(No), Message on Type YES(Yes) Service (TS21, TS22)

Priority of the notificatio n message transmissi on on the FACCH. From high to low, the priorities are A, B, 0, 1, 2, 3, 4 and No Priority. Send SET No SENDFA FACCH GCELLG Priority is GBFDCCHNOT BSC6900 Notificatio SMR(Opti the 510307 PRI n Priority onal) lowest. When the priority of the group call is higher than or equal to the value specified by this parameter , the notificatio n message

Group Call EMLPP

NoPriority (No Priority), Priority4( Priority 4), Priority3( Priority3), Priority2( Enumerati Priority 2), on Type Priority1( Priority 1), Priority0( Priority 0), PriorityB( Priority B), PriorityA( Priority A)

Send SENDFA FACCH CCHPAG Paging PRI Priority

Priority of the paging message transmissi on on the FACCH. From high to low, the priorities are A, B, 0, 1, 2, 3, 4 and No SET Priority. GCELLG No GBFDBSC6900 SMR(Opti Priority is 510307 onal) the lowest. When the priority of the group call is higher than the value specified by this parameter , the paging

Group Call EMLPP

NoPriority (No Priority), Priority4( Priority 4), Priority3( Priority3), Priority2( Enumerati Priority 2), on Type Priority1( Priority 1), Priority0( Priority 0), PriorityB( Priority B), PriorityA( Priority A)

SET The time SENDSA BSC Auto BTSOTH BSC6900 for BTS MBE Link Flag PARA(Op reset. tional)

GBFD111612

MultiCarrier NO(NO), Intelligent Enumerati YES(YES Voltage on Type ) Regulatio n

Whether the BSC Send SET sends the SENDSI2 System OTHSOF System GBFDTERFLA BSC6900 Informatio TPARA(O Informatio 111101 G n 2ter ptional) n Type 2ter message. Whether the BSC Send SET sends the SENDSI5 System OTHSOF System GBFDTERFLA BSC6900 Informatio TPARA(O Informatio 111101 G n 5ter ptional) n Type 5ter message.

System Enumerati NO(No), Informatio on Type YES(Yes) n Sending

System Enumerati NO(No), Informatio on Type YES(Yes) n Sending

SendUtra Send 3G nECSCFl Class ag Flag

Whether the SI Type 3 message contains the 3G Early Classmar k Sending Restrictio n field. The 3G Early Classmar k Sending SET Restrictio OTHSOF n field is GBFDBSC6900 TPARA(O used to 111101 ptional) notify the MS of whether the early classmark message contains the 3G classmark message. This parameter is valid for dualmode MSs and

System Enumerati NO(No), Informatio on Type YES(Yes) n Sending

Split SPT position SEPARA Separate BTSRXU BSC6900 on the TEPOS Position CHAIN(M RXU andatory) chain

GBFD111202

O&M of BTS

Interval Type

0~6

Whether to enable the BTS to support the separatio n between the physical and logical. Whether the BTS supports the ADD SEPERA Separate separate GBFDBSC6900 BTS(Opti TEMODE Mode 111202 mode. onal) When a BTS is in separate mode, the physical boards are separate from the logical TRXs, that is, a physical board may exist without Number of the command listening port of the The server. SET Comman You SERCMD FTPSSR GBFDd Port of BSC6900 should PORT V(Mandat 111203 FTP not use ory) Server any port number occupied by other applicatio ns.

O&M of BTS

SUPPOR T(Support Enumerati ), on Type UNSUPP ORT(Not Support)

O&M of BSC

Interval Type

1024~655 35

Number of the data port of the server in The active SET Source mode. SERDAT FTPSSR GBFDDate Port BSC6900 You APORT V(Mandat 111203 of FTP should ory) Server not use any port number occupied by other applicatio Delivery ADD serial SERIALN Device BTSRET MRFDBSC6900 number of O Serial No. ANT(Man 210602 the RET datory) antenna IP address ADD of the FTP FTPSCLT GBFDFTP Server IP BSC6900 DPORT( server to 111203 Address Mandator be visited y) by the FTP client Service mode of the BSC6900. SET This BSCBASI BSC6900 parameter C(Optiona specifies l) configurat ion mode of subracks. Service ADD bearer BSC6900 BTS(Opti mode of onal) the BTS

O&M of BSC

Interval Type

1024~655 35

Remote String Electrical Type Tilt

None

ServerIP

O&M of BSC

IP Address Type

None

ServiceM Service ode mode

GBFD118602 GBFD113726

SEPARA TE(Separ ate), A over IP Enumerati TOGETH TC Pool on Type ER(Toget her), AIP(AIP)

SERVICE Service MODE Type

GBFD118601

TDM, Abis over Enumerati HDLC, IP on Type HDLC_Hu bBTS, IP

SERVICE Service MODE Type

ADD BTSAUT BSC6900 OPLAN(M andatory)

Service bearer mode of the BTS

GBFD510601

PICO Automatic Enumerati TDM, Configura on Type HDLC, IP tion and Planning

ServiceN Service ame Name

Name of EXP the BSC6900 LOG(Opti command onal) function

GBFD111203 MRFD210305

SERVICE Service TYPE Type

SET BTSVLAN (Mandator y) BSC6900 IMP BTSVLAN (Mandator y)

Service type of the BTS. The QoS processin g depends on the GBFDDSCP, 118601 VLAN ID, and VLAN priority that vary according to the service type.

SYSTEM( System Comman d), CONFIG( Configura tion Managem ent), O&M of MAINTAI BSC Enumerati N(Mainte Security on Type nance Managem Managem ent ent), STAT(Sta tistic Measure ment), ALARM(A larm Managem ent) OML(OM L), RSL(RSL) , EML(EML ), ESL(ESL) , CSVOICE Abis over Enumerati (CS IP on Type Voice), CSDATA( CS Data), PSHIGHP RI(PS High PRI), PSLOWP RI(PS Low PRI),

SET BTSAPM SETDIES Diesel UBP(Opti ELENGIN Engine onal) BSC6900 EENABL Configure SET ED Enabled BTSDPM UBP(Opti onal)

ENV SETENV TEMP PARAEN CFG ABLED Enabled

Whether to enable the diesel engine parameter s to be configure d Whether to enable the environm ent temperatu re alarm parameter s of the APMU to be configure d. The APMU of the SET APM30 BTSAPM type does BSC6900 UBP(Opti not onal) support this parameter . In multimode scenario, the value of this parameter in one mode must be the same as the value of

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

ENV SETENV TEMP PARAEN CFG ABLED Enabled

SET BTSDPM BSC6900 UBP(Opti onal)

SET BTSAPM Environm UBP(Opti SETHUM ent onal) PARAEN Humidity BSC6900 SET ABLED Configure BTSDPM Enabled UBP(Opti onal)

Whether to enable the environm ent temperatu re parameter s to be configure d. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter Whether to enable the environm ent humidity alarm parameter s of the board to be configure d. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

Number of the SFP port. If the switching relation is added on the SFP port, it ADD indicates SFPPOR SFP Port BTSSFP that the GBFDBSC6900 TNO No MODE(M SFP port 111202 andatory) is used to connect the BBU and no RXU chain or ring can be configure d on the

O&M of BTS

Interval Type

0~5

Configure ADD SGSNCA Capacity< SGSNNO BSC6900 P K User DE(Optio Number> nal)

Available capacity GBFDof the 119701 SGSN

SGSN Pool

Interval Type

0~65535

SGSNNA SGSN ME Name

ADD Name of MRFDBSC6900 SGSN(Ma the SGSN 210301 ndatory) Length of the NRI(Netw ork Resource Identifier) ADD or NULLGCNOPE NRI. The GBFDBSC6900 RATOR( length 119701 Mandator determine y) s the maximum value of the NRI and NULLNRI.

Configura tion String Managem Type ent

None

SGSN SGSNNRI NRI LEN Length

SGSN Pool

Interval Type

1~10

SGSN SGSNNU NullNRI LLNRI Value

ADD GCNOPE BSC6900 RATOR( Optional)

SGSNPO Allow OLALLO SGSN W Pool

ADD GCNOPE BSC6900 RATOR( Optional)

Special NRI(Netw ork Resource Identifier). Each SGSN pool has one NULLNRI. When the NRI value GBFDin the 119701 TLLI of the MS uplink/do wnlink service data equals NULLNRI, the BSC6900 reselects an SGSN Whether to enable the SGSN pool function. With SGSN pool, a BSC6900 is connecte d to multiple SGSNs in the pool, and load balancing GBFD119701 and resource sharing between these SGSNs are allowed. In this manner, the PS services are processe d by the SGSNs in the SGSN

SGSN Pool

Interval Type

0~1023

SGSN Pool

Enumerati NO(No), on Type YES(Yes)

SGSNR

Protocol Protocol SET Version version GCELLP GBFDSupporte BSC6900 supported SBASE(O 114101 d by by the ptional) SGSN SGSN

GPRS

Administr ative state of the SGSN. The value "ALLOW" indicates that the SGSN can handle the PS services normally. The value ADD "UNISTAL SGSN SGSNST SGSNNO L" GBFDManagem BSC6900 ATUS DE(Optio indicates 119701 ent Status nal) that the SGSN does not permit new PS services to access the network and the ongoing PS services are not affected. The value Usage threshold of the CPU for call access from other SET SHAREIN CPU. If Share in BSCFCP GBFDCPURAT BSC6900 the usage CPU Rate ARA(Opti 111705 E of the onal) CPU exceeds the threshold, the call access request is

0( Release 98 or Enumerati older), on Type 1(Release 99 onwards)

SGSN Pool

UNISTAL L(Uninstal l), Enumerati ALLOW(A on Type llow), DENY(De ny)

GSM Flow Control

Interval Type

50~95

Load SHARES Sharing N Slot No.

ADD ABISLOA BSC6900 DSHARE( Mandator y)

Slot number of the load GBFDsharing 111203 interface board

O&M of BSC

Interval Type

0~27

SHARING Sharing ALLOW Allow

SET Whether BTSSHA BSC6900 to allow RING(Opt sharing ional)

GBFD118701

RAN Sharing

NO(NO), Enumerati YES(YES on Type )

SHLDFL G

Shield Flag

SET Shield ALMSHL MRFDBSC6900 flag of the D(Mandat 210304 alarm ory)

unshielde Faulty d(Unshiel Enumerati Managem ded), on Type ent shielded( Shielded)

This parameter specifies the delay time before SHUTDO SET Shutdown shutting WNTRXS BTSBAKP GBFDTRX Start BSC6900 down the TARTTIM WR(Optio 111605 Time[T2] TRXs E nal) when the BTS experienc es a power failure.

Active Backup Power Control

Interval Type

0~12

SI2TerSw SI 2ter itch Switch

SET OTHSOF BSC6900 TPARA(O ptional)

SDCCH SIGCHAN HO HOEN Allowed

SET GCELLH BSC6900 OBASIC( Optional)

Whether the BSC sends a System Informatio n Type 2ter message to a nondualband cell. When the parameter is set to YES, the cell does not send the System Informatio n Type 2ter message if the cell is not configure d with interfrequency neighbori ng cells. If the cell is configure d with Whether to enable a handover between signaling channels

GBFD111101

System Enumerati NO(No), Informatio on Type YES(Yes) n Sending

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

Number of times that the Signal ADD downlink Strength GBFDSIGLAST BSC6900 AISSCFG signal Duration 118201 (Optional) strength Times exceeds the threshold ADD MTP3RT( Mandator Uniquely y) Signalling identifies GBFDADD SIGLKSX link set BSC6900 a 111804 MTP3LKS index signaling (Mandator link set y) ADD MTP3LN

SoftSynchroni Interval zed Type Network

1~10

A Interface Protocol Process

Interval Type

0~186

ADD M3RT(Ma ndatory) Signalling ADD SIGLKSX link set BSC6900 M3LKS(M index andatory) ADD M3LNK(M andatory) SIGLNKI D

Uniquely identifies GBFDa 111804 signaling link set

A Interface Protocol Process

Interval Type

0~186

ID of an ADD M3UA link Signaling GBFDBSC6900 M3LNK(M in the link ID 118602 andatory) specified link set Signaling local weight over the local NSVL. When this parameter is set to a larger value, the NS is more ADD Signaling likely to NSVLLO GBFDLoad BSC6900 select this CAL(Opti 118603 Weight IP point onal) according to the load sharing function of the NSVC link of the IP network, if the NS sends a signaling message.

A over IP

Interval Type

0~15

SIGLW

Gb over IP

Interval Type

0~255

SIGLW

ADD Signaling NSVLRE Load BSC6900 MOTE(Op Weight tional)

Signal SIGNALS Service P PRI

SET BSCSRV BSC6900 PRI(Optio nal)

Signaling local weight over the remote NSVL. When this parameter is set to a larger value, the NS is more likely to select this IP point according to the load sharing function of the NSVC link of the IP network, if the NS Priority of the signaling service.0 is the highest priority.

GBFD118603

Gb over IP

Interval Type

0~255

GBFD118605

IP QOS

Interval Type

0~7

SIGOBS

Number Signal of times ADD Strength that the GBFDBSC6900 AISSCFG Observati downlink 118201 (Optional) on Times signal is measured

SoftSynchroni Interval zed Type Network

1~10

Number of measure ment reports used for averaging the signal quality of signaling Filter SET channels. SIGQUAF Length for GCELLH BSC6900 This LTLEN SDCCH OFITPEN parameter Qual (Optional) helps avoid sharp drop of signal levels caused by Raileigh fading and to ID of an ADD MTP3 link Signalling MTP3LN BSC6900 in a link code K(Mandat specified ory) link set

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~31

SIGSLC

GBFD111804 GBFD115301

Number of measure ment reports used for averaging the signal strength of Filter SET signaling SIGSTRF Length for GCELLH BSC6900 channels. LTLEN SDCCH OFITPEN This Level (Optional) parameter helps avoid sharp drop of signal levels caused by Raileigh fading

A Interface Protocol Process Interval Type Local Multiple Signaling Points

0~15

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~31

SET Interval SilenceTi BSCPSS Between cksOfRes BSC6900 OFTPAR Resource Req A(Optiona Request l)

Single SET SinglePas Pass BSCBASI sExclude Exclude BSC6900 C(Optiona Msisdn1 MSISDN l) Number 1

Minimum interval between the successfu l TBF establish ment and the first initiation of the Packet Timeslot Reconfigu ration procedure Single pass exclude MSISDN number 1. One-way audio means that only one party in a call can hear the voice. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string.

GBFD119303

Load Sharing

Interval Type

0~65535

GBFD111203

O&M of BSC

String Type

None

Single Pass SinglePas Exclude sExclude MSISDN Msisdn10 Number 10

SET BSCBASI BSC6900 C(Optiona l)

Single Pass SinglePas Exclude sExclude MSISDN Msisdn11 Number 11

SET BSCBASI BSC6900 C(Optiona l)

Single pass exclude MSISDN number 10. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character Single pass exclude MSISDN number 11. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character

GBFD111203

O&M of BSC

String Type

None

GBFD111203

O&M of BSC

String Type

None

Single Pass SinglePas Exclude sExclude MSISDN Msisdn12 Number 12

SET BSCBASI BSC6900 C(Optiona l)

Single Pass SinglePas Exclude sExclude MSISDN Msisdn13 Number 13

SET BSCBASI BSC6900 C(Optiona l)

Single pass exclude MSISDN number 12. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character Single pass exclude MSISDN number 13. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character

GBFD111203

O&M of BSC

String Type

None

GBFD111203

O&M of BSC

String Type

None

Single Pass SinglePas Exclude sExclude MSISDN Msisdn14 Number 14

SET BSCBASI BSC6900 C(Optiona l)

Single Pass SinglePas Exclude sExclude MSISDN Msisdn15 Number 15

SET BSCBASI BSC6900 C(Optiona l)

Single pass exclude MSISDN number 14. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character Single pass exclude MSISDN number 15. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character

GBFD111203

O&M of BSC

String Type

None

GBFD111203

O&M of BSC

String Type

None

Single Pass SinglePas Exclude sExclude MSISDN Msisdn16 Number 16

SET BSCBASI BSC6900 C(Optiona l)

Single Pass SinglePas Exclude sExclude MSISDN Msisdn17 Number 17

SET BSCBASI BSC6900 C(Optiona l)

Single pass exclude MSISDN number 16. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character Single pass exclude MSISDN number 17. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character

GBFD111203

O&M of BSC

String Type

None

GBFD111203

O&M of BSC

String Type

None

Single Pass SinglePas Exclude sExclude MSISDN Msisdn18 Number 18

SET BSCBASI BSC6900 C(Optiona l)

Single Pass SinglePas Exclude sExclude MSISDN Msisdn19 Number 19

SET BSCBASI BSC6900 C(Optiona l)

Single pass exclude MSISDN number 18. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character Single pass exclude MSISDN number 19. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character

GBFD111203

O&M of BSC

String Type

None

GBFD111203

O&M of BSC

String Type

None

Single SET SinglePas Pass BSCBASI sExclude Exclude BSC6900 C(Optiona Msisdn2 MSISDN l) Number 2

Single Pass SinglePas Exclude sExclude MSISDN Msisdn20 Number 20

SET BSCBASI BSC6900 C(Optiona l)

Single pass exclude MSISDN number 2. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. Single pass exclude MSISDN number 20. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character

GBFD111203

O&M of BSC

String Type

None

GBFD111203

O&M of BSC

String Type

None

Single SET SinglePas Pass BSCBASI sExclude Exclude BSC6900 C(Optiona Msisdn3 MSISDN l) Number 3

Single SET SinglePas Pass BSCBASI sExclude Exclude BSC6900 C(Optiona Msisdn4 MSISDN l) Number 4

Single pass exclude MSISDN number 3. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. Single pass exclude MSISDN number 4. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string.

GBFD111203

O&M of BSC

String Type

None

GBFD111203

O&M of BSC

String Type

None

Single SET SinglePas Pass BSCBASI sExclude Exclude BSC6900 C(Optiona Msisdn5 MSISDN l) Number 5

Single SET SinglePas Pass BSCBASI sExclude Exclude BSC6900 C(Optiona Msisdn6 MSISDN l) Number 6

Single pass exclude MSISDN number 5. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. Single pass exclude MSISDN number 6. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string.

GBFD111203

O&M of BSC

String Type

None

GBFD111203

O&M of BSC

String Type

None

Single SET SinglePas Pass BSCBASI sExclude Exclude BSC6900 C(Optiona Msisdn7 MSISDN l) Number 7

Single SET SinglePas Pass BSCBASI sExclude Exclude BSC6900 C(Optiona Msisdn8 MSISDN l) Number 8

Single pass exclude MSISDN number 7. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. Single pass exclude MSISDN number 8. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string.

GBFD111203

O&M of BSC

String Type

None

GBFD111203

O&M of BSC

String Type

None

Single pass exclude MSISDN number 9. Certain numbers, such as the Single SET premium SinglePas Pass BSCBASI rate GBFDsExclude Exclude BSC6900 C(Optiona number, 111203 Msisdn9 MSISDN l) are not Number 9 used for the single pass check. The number is stored in character string.

O&M of BSC

String Type

None

SIPADDR

PING Source IP Source IP BSC6900 IP(Manda None address address tory)

None

IP Address Type

None

SIPADDR

TRC Source IP Source IP BSC6900 IPADDR( None address address Optional) Log of COL which site GBFDBSC6900 LOG(Opti need to 111203 onal) be collected.

None

IP Address Type

None

SITES

Sites

O&M of BSC

Interval Type

0~65535

SET SITESYN Site Sync BTSAISS( BSC6900 CZONE Zone Mandator y)

SET Clock SLAVEIP BTSIPCL Server IP BSC6900 ADDR KPARA(M Address 2 andatory)

SubSLAVELO Location CGRPNO Group No.

ADD BTSBIND BSC6900 LOCGRP( Mandator y)

Zone where the BTS synchroni zes with other BTSs. Only two BTSs with the same synchroni zation zone can be synchroni zed in a synchroni zation The IP address must be a valid class A, B, or C address, and it cannot be a broadcast address or network No. of the location group under the BTS. The location group No. is unique for each BTS.

GBFD118201

SoftSynchroni Interval zed Type Network

0~255

GBFD118606

Clock over IP

IP Address Type

None

GBFD510104

Multi-site Interval Cell Type

0~35

Self-loop type. The precautio ns are as follows: 1. If the self-loop type is set to "E1SELF LOOP" and the BTS type is BTS3002 STR C, TRANSP Self Loop BTS3001 GBFDSLPTYPE BSC6900 ERFTST( Type 111207 C, or Mandator BTS3001 y) CP, the transmissi on board type can be set to only "Active TMU/MM U/IOMU/ DOMU". If the BTS type is BTS3006 C or BTS3002

E1SELFL OOP(E1 Self Loopback BTS Test Enumerati ), Function on Type IASUSEL FLOOP(I ASU Self Loopback )

Signaling route load sharing. In the value, the number of 1s (represent ed by n) determine s the maximum number (2) of routes for the load Signalling ADD SLSMAS sharing. GBFDroute BSC6900 N7DPC(O K 111804 For mask ptional) example, B0000 indicates that up to one route is used for the load sharing, B0001 and B1000 indicate that up to two routes are

A Interface Protocol Process

B0000(B0 000), B0001(B0 001), B0010(B0 010), B0011(B0 011), B0100(B0 100), B0101(B0 101), B0110(B0 110), B0111(B0 Enumerati 111), on Type B1000(B1 000), B1001(B1 001), B1010(B1 010), B1011(B1 011), B1100(B1 100), B1101(B1 101), B1110(B1 110), B1111(B1 111)

Slave SLVSER Service VACTDE Active LAY Delay

If no handshak e message is received from the peer within the delay, the slave service is activated. A slave service SET object GBSCRE provides GBFDBSC6900 DGRP(Op services 113725 tional) at the peer BSC and its configurat ion data is backed up at the local BSC. A slave service object provides services at the local BSC

BSC Node Interval Redunda Type ncy

1~600

SM

Type of the start date. "WEEK" indicates that the start date is a weekday. "DATE" indicates that the SET start date StartType BSC6900 TZ(Mand is a atory) month day. "DATEW EEK" indicates the start date is expresse d by a combinati on of weekday and

GBFD116101 MRFD210301

DATE(Inp Support ut with of date), Daylight WEEK(In Saving put with Enumerati Time week), on Type Configura DATEWE tion EK(Input Managem with date ent and week)

SMLC SMLCIDX Index

ADD GEXTSM Index of BSC6900 None LC(Mand the SMLC atory) Whether the builtADD in SMLC GEXTSM or BSC6900 LC(Mand external atory) SMLC is used in the BSS.

None

Interval Type

0~3

SMLCMo SMLC de Mode

None

None

NOTSUP PORT(No t Enumerati Support), on Type INNER(In ner), OUTER( Outer)

Enable ADD Smog SMOKE_ Smoke BSC6900 EMU(Opti alarm MASK Alarm onal) switch Reporting

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

Start SMONTH month

Month in SET which BSC6900 TZ(Mand DST atory) starts

GBFD116101 MRFD210301

JAN(Janu ary), FEB(Febr uary), MAR(Mar ch), APR(April Support ), of MAY(May Daylight ), Saving Enumerati JUN(June Time on Type ), Configura JUL(July), tion AUG(Aug Managem ust), ent SEP(Sept ember), OCT(Octo ber), NOV(Nov ember), DEC(Dec

SMWIND Filter OW window

SET FCCPUT HD(Optio nal) BSC6900 SET FCMSGQ THD(Opti onal)

Number of CPU usage samples involved in the GBFDcalculatio 111705 n of the average CPU usage in the sliding window

GSM Flow Control

Interval Type

2~2000

SN

Slot No.

SWP BRD(Man datory) STR BKP(Man datory) CMP BRDARE A(Optiona l) ULD RSTINFO (Mandator y) SET CLK(Man Number MRFDdatory) BSC6900 of the slot 210301 UPD JTGCPLD (Mandator y) SET XPUPOR T(Mandat ory) ADD XPUVLA N(Mandat ory) SET MPUBIN D(Mandat ory) SET DLD TCFILE( Number MRFDBSC6900 Mandator of the slot 210301 y) ADD MTP3LN K(Optiona BSC6900 l) ADD SCTPLN K(Mandat Number of the slot where the None XPU board is located Number of the slot ADD where the GBFDBSC6900 M3LNK(M XPU 118602 andatory) board is located

Configura tion Interval Managem Type ent

0~27

SN

Slot No.

Configura tion Interval Managem Type ent

0~3,8~27

SN

Slot No.

None

Interval Type

0,2,4,8,10 ,12,14,16, 18,20,22, 24,26 0,2,4,8,10 ,12,14,16, 18,20,22, 24,26

SN

Slot No.

Interval A over IP Type

SN

Slot No

SET PHBMAP( Mandator y) ADD Number BSC6900 ATERE1T None of the slot 1(Mandat ory) ADD AE1T1(M andatory)

None

Interval Type

0~5,8~27

SN

BM Slot No

A key field used to identify the Ater BLK timeslot ATERE1T and BSC6900 None 1(Mandat indicate ory) the number of the Ater interface timeslot

None

Interval Type

0~5,8~27

SN

Slot No.

SN

Slot No.

BLK AE1T1(M andatory) BSC6900 ADD PBE1T1( Mandator y) EXP ALMLOG( Optional) BSC6900 STA ALMLOG( Optional)

Number GBFDof the slot 111203

O&M of BSC

Interval Type

0~27

Number of the slot MRFDwhere the 210304 alarm is generated

Faulty Interval Managem Type ent

0~27

SN

SN

SN

Number of the slot where the alarm is generated ADD , the OBJALM number of MRFDSlot No. BSC6900 SHLD(Op the slot 210304 tional) where the OMU board is positioned is not supported SET E1T1LOP (Mandator y) LOP E1T1(Ma ndatory) STR E1T1TST (Mandator y) SET OPTLOP( Mandator Indicates y) the slot PING number IP(Manda Slot No. BSC6900 for None tory) running TRC this IPADDR( command Mandator y) SET QUEUEM AP(Mand atory) SET E1T1(Ma ndatory) ADD TSCROS S(Mandat ory) ADD SWP ETHPOR Slot Main T(Mandat number Board for ory) BSC6900 None Logic slot running ADD No. ETHRED this PORT(Ma command ndatory)

Faulty Interval Managem Type ent

0~27

None

Interval Type

0~5,8~27

None

Interval Type

0,2,4,8,10 ,12,14,16, 18,20,22, 24,26

SN

Slot No.

ADD GCBSAD DR(Mand atory) SET TCPLYV BSC6900 OICE(Ma ndatory) SET TCPARA( Mandator y)

Number of the slot. The subrack number MRFDand slot 210301 number uniquely identify a board.

Configura tion Interval Managem Type ent

0~27

SN

Slot No.

SN

Slot No.

Slot No. of the subsyste ADD m where GIURGC the Iur-g MRFDBSC6900 ONN(Man common 211402 datory) connectio n is establishe d ADD TRXBIND 2PHYBR D(Mandat ory) SWP BTSRING (Optional) SWP BTSOML LINK(Opti onal) SET BTSFMU ABP(Man Number of the slot datory) where the GBFDSET BSC6900 111202 BTSNFC BTS BBP(Man board is located datory) SET BTSPMU BP(Mand atory) SET BTSAPM UBP(Man datory) SET BTSDAT UBP(Man datory) SET BTSDEM

MBSC Interval Load Type Balancing

0~27

O&M of BTS

Interval Type

0~23

SN

Slot No.

ADD BTSBFD( Optional) BSC6900 ADD BTSIPRT BIND(Opti onal)

Number of the slot where the GBFDBTS 118609 board is located

IP Fault Detection Interval Based on Type BFD

0~23

SN

Slot No.

Slot number of ADD the XPU MRFDBSC6900 NSE(Man board 210301 datory) bound to the NSE Slot number of ADD board to GBFDBSC6900 PBSL(Ma which Pb 111203 ndatory) signaling link belongs ADD BTSSFP MODE(O ptional) SET BTSFOR BIDTS(O ptional) SET BTSOML TS(Option al) SET BTSETH PORT(Op Number tional) of the slot GBFDADD BSC6900 where the 111202 BTSPPPL port is NK(Optio located nal) ADD BTSMPL NK(Optio nal) ADD BTSETH MA(Optio nal) ADD BTSETHL CMEP(Op tional) ADD BTSTOP

Configura tion Interval Managem Type ent

0,2,4,8,10 ,12,14,16, 18,20,22, 24,26

SN

Slot No.

O&M of BSC

Interval Type

0~27

SN

Port Slot No.

O&M of BTS

Interval Type

0~23

SN

Slot No.

Slot number of the ADD BSC6900 BTSCON GBFDBSC6900 board that NECT(Ma 111202 is ndatory) connecte d to the BTS OPR BTSBRD BSC6900 PWR(Ma ndatory) Number of the slot where the GBFDBTS 111202 board is located.

O&M of BTS

Interval Type

0~27

SN

Slot No.

O&M of BTS

Interval Type

0~7

SNDMD

Send Mode

RF send mode of the TRX. The BTS3006 C and BTS3002 E do not support Wide Band Combinin g, Power Booster Technolo SET gy, DPBT, GTRXDE or MRFDBSC6900 V(Optiona Transmitt 210301 l) er Independ ent or Combinin g. The DBS3900 GSM GRRU does not support Wide Band Combinin g, Transmitt

NOCOMB (No Combinati on), PBT(PBT) , WBANDC OMB(Wid eband Combinati on), DIVERSI TY(Trans Configura mit tion Enumerati Diversity), Managem on Type DDIVERS ent ITY(Dyna mic Transmit Diversity), DPBT(DP BT), DTIC(Tra nsmit Independ ency or Combinati on), NONE(no ne)

The connectio DRRU SET n mode SndRcvM Sending BTSRXU GBFDBSC6900 between ode Receiving BP(Optio 111202 the DRRU Mode nal) and the antenna.

O&M of BTS

SGL_ANT ENNA(Sin gle Feeder[1 TX + 1RX]), SGLDOU BLE_ANT ENNA(Sin gle Feeder[1 TX + 2RX]), DOUBLE _ANTEN NA(Doubl Enumerati e on Type Feeder[2 TX + 2RX]), DOUBLE FOUR_A NTENNA( Double Feeder[2 TX + 4RX]), DOUBLE SINGLE_ ANTENN A(Double Feeder[1 TX + 1RX]),

The connectio DRFU SET n mode SndRcvM Sending BTSRXU GBFDBSC6900 between ode1 Receiving BP(Optio 111202 the DRFU Mode nal) and the antenna.

O&M of BTS

SGL_ANT ENNA(Sin gle Feeder[1 TX + 1RX]), SGLDOU BLE_ANT ENNA(Sin gle Feeder[1 TX + 2RX]), DOUBLE _ANTEN NA(Doubl Enumerati e on Type Feeder[2 TX + 2RX]), DOUBLE FOUR_A NTENNA( Double Feeder[2 TX + 4RX]), DOUBLE SINGLE_ ANTENN A(Double Feeder[1 TX + 1RX]),

The connectio MRRU/G n mode SET RRU between SndRcvM BTSRXU GBFDSending BSC6900 the ode2 BP(Optio 111202 Receiving MRRU/G nal) Mode RRU and the antenna.

O&M of BTS

SGL_ANT ENNA(Sin gle Feeder[1 TX + 1RX]), SGLDOU BLE_ANT ENNA(Sin gle Feeder[1 TX + 2RX]), DOUBLE _ANTEN NA(Doubl Enumerati e on Type Feeder[2 TX + 2RX]), DOUBLE FOUR_A NTENNA( Double Feeder[2 TX + 4RX]), DOUBLE SINGLE_ ANTENN A(Double Feeder[1 TX + 1RX]),

The connectio MRFU/G n mode SET RFU between SndRcvM BTSRXU GBFDSending BSC6900 the ode3 BP(Optio 111202 Receiving MRFU/G nal) Mode RFU and the antenna.

O&M of BTS

SGL_ANT ENNA(Sin gle Feeder[1 TX + 1RX]), SGLDOU BLE_ANT ENNA(Sin gle Feeder[1 TX + 2RX]), DOUBLE _ANTEN NA(Doubl Enumerati e on Type Feeder[2 TX + 2RX]), DOUBLE FOUR_A NTENNA( Double Feeder[2 TX + 4RX]), DOUBLE SINGLE_ ANTENN A(Double Feeder[1 TX + 1RX]), SGL_ANT ENNA(Sin gle Feeder[1 TX + 1RX]), DOUBLE SINGLE_ Enumerati ANTENN on Type A(Double Feeder[1 TX + 1RX]), DOUBLE DOUBLE _ANTEN NA(Doubl e

The connectio BTS3900 SET n mode E SndRcvM BTSRXU between GBFDSending BSC6900 ode4 BP(Optio the 111202 Receiving nal) BTS3900 Mode E and the antenna.

O&M of BTS

SP

Sync Period

SET SNTPCLT BSC6900 PARA(Ma ndatory)

Synchroni zation period of GBFDthe SNTP 111203 client service

O&M of BSC

Interval Type

1~60

SPC

As an integer, the OSP code can be expresse d by a decimal OSP digit or a ADD code[Who hexadeci BSC6900 OPC(Opti le mal digit. onal) Number] If the OSP code is expresse d by a hexadeci mal digit, H' is added

GBFD111802 GBFD111804

14-Digit Signaling Point Code Interval A Type Interface Protocol Process

1~167772 15

Number of bits ADD contained OSP code SPCBITS BSC6900 OPC(Man in the bits datory) signaling point code OSP code expresse d in the form of segments OSP ADD 8-8-8, see code[Divi SPCDNF BSC6900 OPC(Opti the ded onal) parameter Number] "Signal point data format" of the "ADD OPC"

GBFD111802 GBFD111804

14-Digit Signaling BIT14(BIT Point 14), Code Enumerati BIT16(BIT A on Type 16), Interface BIT24(BIT Protocol 24) Process

GBFD111802 GBFD111804

14-Digit Signaling Point Code String A Type Interface Protocol Process

None

SPCIC

Start PCIC

Start CIC ADD of the PBE1T1( GBFDBSC6900 E1/T1 of Mandator 111203 the Pb y) interface

O&M of BSC

Interval Type

0~65535

SPDF

ADD OPC(Opti Signal onal) point data BSC6900 ADD format N7DPC(O ptional)

Special SPECAC Access C Control Class

SET GCELLC BSC6900 CBASIC( Optional)

Data format of the specified signaling point. When this parameter is set to "WNF", the SPC is expresse d in the form of an integer number. When this parameter is set to "NDF", the SPC is expresse d in three segments . The number of bits included in each segment depends on the This parameter is used for load control. It determine s whether the users of special access class are allowed to access the network. Value 1 indicates that access is not allowed. Value 0 indicates that access is allowed.

GBFD111804

A Interface Protocol Process

WNF(Wh ole Number Enumerati Format), on Type DNF(Divi ded Number Format)

GBFD111003 GBFD110301 GBFD110302

Radio Common Channel Managem Bit Field ent Type Location Updating IMSI Detach

L11_FOR BID, L12_FOR BID, L13_FOR BID, L14_FOR BID, L15_FOR BID

Special SPECIAL Alarm SWITCH Switch

The value of this parameter consists of seven bits. Each bit determine s whether to enable the oneway Boolean alarm. "0" indicates SET that the BTSFMU one-way MRFDBSC6900 ABP(Opti Boolean 210304 onal) alarm is enabled, and "1" indicates that the one-way Boolean alarm is disabled. In multimode scenario, the value of this parameter in one

Faulty Bit Field Managem Type ent

ET_DISA BLE0, ET_DISA BLE1, SMDISAB LE, WIDISAB LE, GMDISAB LE, ARREST ER1, ARREST ER2

Special Alarm SET SPECIAL Valid BTSFMU SWITCH BSC6900 Level ABP(Opti ERLEVEL Configura onal) tion

One-Way SET Mute SpeechAl BSCBASI Alarm BSC6900 mPeriod C(Optiona Reporting l) Period

The value of this parameter consists of five bits. Each bit determine s whether the oneway Boolean alarm is triggered by low level or high level. "0" indicates that the alarm is triggered by high level, and "1" indicates that the alarm is triggered by low level. In multimode scenario, If the number of one-way mute events exceeds the value of "Speech Channel Alarm Threshold " within this period, then the BSC reports the Speech

MRFD210304

Faulty Bit Field Managem Type ent

SMDISAB LE, WIDISAB LE, GMDISAB LE, ARREST ER1, ARREST ER2

GBFD111803

A Interface Interval Circuit Type Managem ent

1~12

Whether to contain the informatio Speech SET n element SpeechV VER MSGSOF of GBFDerInAssC Send Flag BSC6900 TPARA(O Speech_ 111804 mp in ASS ptional) Ver in the CMP Assignme nt Complete message

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether to contain the Speech informatio SET SpeechV VER n element MSGSOF GBFDerinHoPer Send Flag BSC6900 of TPARA(O 111804 form in HO Speech_ ptional) Perform Ver in the Handover Perform message

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether to contain the SpeechV informatio SET SpeechV erSend n element MSGSOF GBFDerInHoRe Flag in BSC6900 of TPARA(O 111804 qAck HO REQ Speech_ ptional) ACK Ver in the HO_REQ _ACK message

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

Whether to contain the SET SpeechV HO_RQD informatio MSGSOF GBFDerInHoRq Speech BSC6900 n element TPARA(O 111804 d VER of Speech ptional) Ver in the HO_RQD message

A Interface Protocol Process

Enumerati NO(No), on Type YES(Yes)

SPEECH Speech VERMOD Version E1 Mode 1

Speech version mode that the BTS SET uses for BTSCHN the VGCS GBFDBSC6900 FALLBAC call 510309 K(Mandat number in ory) the timeslot in the TRX in fallback mode

PSMODE Group (Protocol Call Standard Enumerati Reliability Mode), on Type Enhancin VGCSMO g DE(VGCS Mode)

SPEECH Speech VERMOD Version E2 Mode 2

Speech version mode that the BTS SET uses for BTSCHN the VGCS GBFDBSC6900 FALLBAC call 510309 K(Mandat number in ory) the timeslot in the TRX in fallback mode

PSMODE Group (Protocol Call Standard Enumerati Reliability Mode), on Type Enhancin VGCSMO g DE(VGCS Mode)

SPEECH Speech VERSION Version

Speech version configure d on the TRX timeslot when the BTS works in fallback mode. When "CHNTYP E" of the TRX SET timeslot is BTSCHN GBFDset to BSC6900 FALLBAC "FULLTC 510309 K(Mandat H", value ory) 0 of this parameter indicates FR and value 1 indicates EFR; when "CHNTYP E" of the TRX timeslot is set to "HALFRC H", this

Group Call FR(FR), Enumerati Reliability EFR(EFR on Type Enhancin ) g

SPEED

Rate over the GE electrical port. When this parameter is set to 1000M, the GE electrical port performs negotiatio n at the rate of SET 1000 ETHPOR ETHPOR Mbit/s. If, BSC6900 None T SPEED T(Optiona however, l) the negotiatio n result is not 1000 Mbit/s, the negotiatio n fails. When this parameter is set to AUTO, the GE electrical port performs auto

None

1000M(10 Enumerati 00M), on Type AUTO(AU TO)

Penalty on MS SPEEDP Fast UNISH Moving HO

Level value of the penalty that is performe d on the neighbori ng cells of the cell where a fastSET moving GCELLH MS is BSC6900 OAD(Opti located. onal) The neighbori ng cells must be located at the Macro, Micro, or Pico layer other than the Umbrella layer.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

Penalty Time on SPEEDP Fast UNISHT Moving HO

Period in which penalty is performe d on the neighbori ng cells of the cell where a fastmoving SET MS is GCELLH located. BSC6900 OAD(Opti The onal) neighbori ng cells must be located at the Macro, Micro, or Pico layer but not the Umbrella layer.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

Whether to support SPLIT_P G_CYCL E on CCCH. The parameter SPLIT_P G_CYCL E is used to define the DRX period. You can Support SET specify SPLIT_P SPGCCC GCELLP whether G_CYCL BSC6900 CHSUP SBASE(O the E on ptional) paging CCCH group based on SPLIT_P G_CYCL E is supported on CCCH for the BTS and the MS. Yes: the paging group based on SPLIT_P

GBFD111101 GBFD114802

System Informatio n Sending NO(NO), Enumerati Discontin YES(YES on Type uous ) Reception (DRX)

SpprtCB

ADD Support GCNOPE Cell BSC6900 RATOR( Broadcast Optional)

Allow Common ADD SPTCOM Measure BSC6900 GNRNC( MMEAS ment at Optional) Iur-g

This parameter specifies whether the BSC6900 supports the cell broadcast function and whether the BSC6900 supports simple cell broadcast or standard cell broadcast . If the BSC6900 supports standard cell broadcast , the BSC6900 should be connecte d to the Whether to support the common bidirection al measure ment procedure on the Iurg Whether

GBFD113601

NOTSPP RTBC(No tSupport CB), Short SPPRTS Message TANDAR Service Enumerati D(Support Cell on Type Standard Broadcast CB), (TS23) SPPRTSI MPLE(Su pportSimp le CB)

MRFD211402

NO(No MBSC Enumerati Support), Load on Type YES(Sup Balancing port)

to support the bidirection Allow Info ADD SPTINFO MRFDal Exchange BSC6900 GNRNC( EXCHG informatio 211402 at Iur-g Optional) n exchange procedure on the Iur-

NO(No MBSC Enumerati Support), Load on Type YES(Sup Balancing port)

Support SET SPTINTE In InterGCELLG RRATINB RAT Inter- BSC6900 PRS(Opti SCPSHO cell PS onal) Handover

Support SPTINTE SET Out InterRRATOU GCELLG RAT Inter- BSC6900 TBSCPS PRS(Opti Cell PS HO onal) Handover

Support SET SPTNAC NACC BSCPSS CResGua Resource BSC6900 OFTPAR rantee Guarante A(Optiona e l)

Whether to support In InterRAT Intercell PS Handover . The MS in the UMTS cell can be handed over to the BSC local cell through PS Whether support Out InterRAT InterCell PS Handover . The MS in the BSC local cell can be handed over to the UMTS cell through PS Whether the function of Network Assisted Cell Change (NACC) resource guarantee is allowed. In NC2 or NACC cell reselectio n, if this parameter is set to YES, dynamic channels are requested

GBFD119502

UNSUPP ORT(Not PS Enumerati Support), Handover on Type SUPPOR T(Support )

GBFD119502

UNSUPP ORT(Not PS Enumerati Support), Handover on Type SUPPOR T(Support )

GBFD116301

Network Assisted Cell Change (NACC)

NO(NO), Enumerati YES(YES on Type )

Whether the BSC forwards the paging message from the trunking MSC to the MS. When this parameter is set to YES, the Support BSC Paging ADD forwards SptPagin Message GCNNOD GBFDBSC6900 the g from E(Optiona 510301 paging Trunking l) message MSC from the trunking MSC to the MS and forwards the correspon ding paging response from the MS to the trunking

Public Voice Group Call Service

Enumerati NO(No), on Type YES(Yes)

Support SptPbLap Pb Lapd dCheck Check

Whether to enable the layer 3 check mechanis m on the LAPD links. If the PCU_BS C_LAPD_ CHECK_ ACK message cannot be SET received OTHSOF on one Pb GBFDBSC6900 TPARA(O link, the 114101 ptional) Pb link is in single pass mode. Send another two PCU_BS C_LAPD_ CHECK_ ACK message s. If the PCU_BS C_LAPD_ CHECK_

GPRS

Enumerati NO(No), on Type YES(Yes)

Whether to enable the enhanced resource check on the Pb interface. The introducti on of enhanced resource check is to Support SET improve SptPbRes Pb OTHSOF the GBFDBSC6900 Check Resource TPARA(O efficiency 114101 Check ptional) of resource checking and define the dependen cies of resource status. The external PCU initiates the enhanced resource

GPRS

Enumerati NO(No), on Type YES(Yes)

Whether to enable the single pass check function on the Pb links between the BSC and the external PCU. When the Pb link is Support SET in single SptPbSgl Pb Single OTHSOF pass GBFDPassChec BSC6900 Pass TPARA(O mode, a 114101 k Check ptional) correspon ding alarm is reported to the maintena nce terminal, and the Pb link is set to broken link state or the priority of the Pb

GPRS

Enumerati NO(No), on Type YES(Yes)

SptPCIC Check

Support PCIC Check

Whether to enable the PCIC check function on the Pb links between the BSC and the external PCU. When the configurat ion of the SET PCIC of OTHSOF the BSC GBFDBSC6900 TPARA(O is 114101 ptional) inconsiste nt with that of the external PCU, a correspon ding alarm is reported to the maintena nce terminal, the Pb interface circuit

GPRS

Enumerati NO(No), on Type YES(Yes)

Support SptRanSh RAN aring Sharing

SET BSCBASI BSC6900 C(Optiona l)

Support SET SPTRED Reduced GCELLG UCELAT BSC6900 Latency PRS(Opti ENCY Capability onal)

Whether to support RAN Sharing.R AN sharing refers to the technique that the GBSS equipmen t is categoriz ed into multiple logical GBSS equipmen t, thus operators can share the GBSS equipmen t to cover the same area. Cell supports reduced latency capability. This parameter is used to reduce the latency during the transmissi on, thus improving the user experienc e for conversati onal services.

GBFD118701

RAN Sharing

Enumerati NO(No), on Type YES(Yes)

GBFD510805

UNSUPP ORT(Not Latency Enumerati Support), Reduction on Type SUPPOR T(Support )

whether the main operator enables the RanShari ng function. SET RanShari If the SPTSHA BTSRXU GBFDng BSC6900 RanShari RING BP(Optio 118701 Support ng nal) function is enabled, one to three cooperators can be configure d to share Whether the FTP SET client BSC6900 FTPSCLT supports (Optional) the state firewall

RAN Sharing

NO(NO), Enumerati YES(YES on Type )

Support SPTSTAT State EFWL Firewall

GBFD111203

O&M of BSC

YES(Sup Enumerati port), on Type NO(Not Support)

SPX

OSP index

ADD OPC(Man datory) ADD Uniquely GBFDBSC6900 N7DPC(M identifies 111804 andatory) an OSP ADD M3LE(Ma ndatory)

A Interface Protocol Process

Interval Type

0~4

Whether a base station supports normalize d data configurat ion. Normalize d data configurat ion means that the cabinets, Is Support subracks, Normalize ADD SRANMO GBFDslots, d Data BSC6900 BTS(Man DE transmissi 111202 Configura datory) on ports, tion and userdefined alarm ports of a base station under a multimode BSC use the same numberin g schemes, and that

O&M of BTS

SUPPOR T(Support ), Enumerati NOT_SU on Type PPORT(N ot Support)

ADD Is Support SRANMO BTSAUT SingleRA BSC6900 DE OPLAN(M N Mode andatory)

ADD Is Support SRANMO BTSCABI SingleRA BSC6900 DE NET(Opti N Mode onal)

Whether the data configurat ion of the SingleRA N BTS supports normalize d SingleRA N mode. Normalize d SingleRA N mode means that the rules of defining cabinet number, subrack number, and slot number of the SingleRA N BTS Whether the data configurat ion of the SingleRA N BTS supports normalize d SingleRA N mode. Normalize d SingleRA N mode means that the rules of defining cabinet number, subrack number, and slot number of the SingleRA N BTS

GBFD111202

O&M of BTS

SUPPOR T(Support ), Enumerati NOT_SU on Type PPORT(N ot Support)

GBFD111202

O&M of BTS

SUPPOR T(Support SRAN), Enumerati NOT_SU on Type PPORT(N ot Support)

ADD G2GNCE LL(Manda SRC2GN Source tory) BSC6900 CELLID Cell Index ADD GIBCAPN CGRP(M andatory)

A cell Index must be unique in one BSC6900 . It is used to uniquely identify a

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~2047

ADD G2GNCE LL(Manda SRC2GN Source tory) Name of CELLNA Cell BSC6900 ADD a cell ME Name GIBCAPN CGRP(M andatory) A source cell index must be unique in one BSC. It is used to ADD uniquely SRC3GN Source G3GNCE BSC6900 identify a CELLID Cell Index LL(Manda source tory) cell. The value of this parameter ranges from 0 to 2047. ADD Name of G3GNCE BSC6900 a source LL(Manda cell tory)

MRFD210301

Configura tion String Managem Type ent

None

MRFD210301

Configura tion Interval Managem Type ent

0~2047

SRC3GN Source CELLNA Cell ME Name

MRFD210301

Configura tion String Managem Type ent

None

SRCCI

Source Cell CI

ADD G2GNCE Source BSC6900 LL(Manda cell ID tory)

MRFD210301

Configura tion Interval Managem Type ent

0~65535

SRCF

The batch file to be executed: The content of the batch file consists of service command s to be executed in batches. The RUN source file Source BATCHFI is located GBFDBSC6900 File Name LE(Mand in the 111203 atory) FTP subdirect ory of the OMU installatio n directory, and you should not add the path when entering the name. The character SET Priority of CLKMOD MRFDBSC6900 the clock E(Mandat 210502 source ory)

O&M of BSC

String Type

None

Clock SRCGRD source priority

BSC/RNC Interval Clock Type

1~4

Clock SRCGRD source priority

Priority of the clock source. ADD There are CLKSRC( four MRFDBSC6900 Mandator priorities 210502 y) (in descendin g order): 1, 2, 3, 4.

BSC/RNC Interval Clock Type

1~4

Current ADD SRCHOC HO CTRL G2GNCE TRLSWIT Algorithm BSC6900 LL(Option CH in Source al) Cell

SRCIP

ADD Source IP BTSBFD( BSC6900 Address Mandator y) ADD G2GNCE BSC6900 LL(Manda tory)

Whether the currently used handover algorithm in the source cell is HO Algorithm I or HO Algorithm II Source IP address of BFD Session.

GBFD110601 GBFD510501

HOALGO RITHM1( HUAWEI Handover I algorithm Handover Enumerati I), HUAWEI on Type HOALGO II RITHM2( Handover Handover algorithm II) IP Fault IP Detection Address Based on Type BFD Configura tion Interval Managem Type ent

GBFD118609

None

Source SRCLAC Cell LAC

Local area code (LAC) of MRFDthe 210301 source cell Mobile country code (MCC) of the source cell Identifies a maintena nce point in the maintena nce group Mobile network code (MNC) of the source cell

1~65533, 65535

ADD Source G2GNCE SRCMCC BSC6900 Cell MCC LL(Manda tory) PING MAC(Man datory) BSC6900 TRC MAC(Man datory)

MRFD210301

Configura tion String Managem Type ent

None

SRCMEPI MEP ID D

None

None

Interval Type

1~1000

ADD Source G2GNCE SRCMNC BSC6900 Cell MNC LL(Manda tory)

MRFD210301

Configura tion String Managem Type ent

None

SRCPOR Source TNO port No.

ADD Source of TSCROS BSC6900 timeslot None S(Mandat cross ory)

None

Interval Type

0~335

SRCT

Clock source type

ADD Type of CLKSRC( MRFDBSC6900 the clock Mandator 210502 source. y)

BITS12MHZ(2M HZ Building Integrated Timing Supply system 1), BITS22MHZ(2M HZ Building Integrated Timing Supply system BSC/RNC Enumerati 2), BITS1Clock on Type 2MBPS(2 MBPS Building Integrated Timing Supply system 1), BITS22MBPS(2 MBPS Building Integrated Timing Supply system 2), 8KHZ(8K

Source SRCTSM timeslot ASK mask

ADD Source TSCROS BSC6900 timeslot S(Mandat mask ory)

None

None

Bit Field Type

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

SRN

Subrack No.

SRN

Subrack No.

SRN

Subrack No.

SWP BRD(Man datory) STR BKP(Man datory) CMP BRDARE A(Optiona l) ULD LOGTOO MU(Mand atory) ULD RSTINFO (Mandator BSC6900 y) SET PWRALM SW(Mand atory) SET PWRPAR A(Mandat ory) SET FANSPE ED(Mand atory) SET SCUPOR T(Mandat ory) ADD SUBRAC K(Mandat BSC6900 ory) SET CLK(Man datory) ADD MTP3LN K(Optiona BSC6900 l) ADD SCTPLN K(Mandat

Number of the subrack

MRFD210301

Configura tion Interval Managem Type ent

0~11

Number of the subrack

MRFD210301

Configura tion Interval Managem Type ent

1~11

Number of the subrack where the None XPU board is located

None

Interval Type

0~11

SRN

Subrack No.

ADD RSCGRP (Mandator y) SET PHBMAP( Mandator y) ADD ATERE1T 1(Mandat Number ory) BSC6900 of the ADD subrack AE1T1(M andatory) BLK AE1T1(M andatory) ADD ABISLOA DSHARE( Mandator y) ADD ADD Number BSC6900 M3LNK(M of the andatory) subrack

None

None

Interval Type

0~11

SRN

Subrack No.

GBFD118602

A over IP

Interval Type

0~11

SRN

BM Subrack No

It is one key field of identifying the Ater BLK timeslot ATERE1T and BSC6900 None 1(Mandat indicates ory) the subrack No. of the Ater interface timeslot.

None

Interval Type

0~11

SRN

Subrack No

COL Number BSC6900 LOG(Opti of the onal) subrack EXP ALMLOG( Optional) STA ALMLOG( BSC6900 Optional) ADD OBJALM SHLD(Ma ndatory)

None

None

Interval Type

0~11

SRN

Subrack No.

Number of the subrack where the MRFDindicator 210304 alarm to be queried is generated

Faulty Interval Managem Type ent

0~11

SRN

Subrack No.

SRN

Subrack No.

ADD ETHMD( Mandator y) ADD ETHTRK( Mandator y) ADD BSC6900 ETHTRKL NK(Mand atory) ADD ETHTRKI P(Mandat ory) STR ETHMIRR ORPORT ADD GCBSAD DR(Mand atory) SET TCPLYV BSC6900 OICE(Ma ndatory) SET TCPARA( Mandator y)

The subrack number for None running this command

None

Interval Type

0~11

The subrack number MRFDuniquely 210301 identifies a subrack.

Configura tion Interval Managem Type ent

0~11

SRN

Subrack No.

Subrack No. of the subsyste ADD m where GIURGC the Iur-g MRFDBSC6900 ONN(Man common 211402 datory) connectio n is establishe d

MBSC Interval Load Type Balancing

0~11

SRN

Subrack No.

SRN

Subrack No.

ADD TRXBIND 2PHYBR D(Mandat ory) SWP BTSRING (Optional) SWP BTSOML LINK(Opti onal) SET BTSFMU ABP(Man datory) SET BSC6900 BTSNFC BBP(Man datory) SET BTSPMU BP(Mand atory) SET BTSAPM UBP(Man datory) SET BTSDAT UBP(Man datory) SET BTSDEM ADD BTSBFD( Optional) BSC6900 ADD BTSIPRT BIND(Opti onal)

Number of the subrack GBFDwhere the 111202 BTS board is located

O&M of BTS

Interval Type

0~254

SRN

Subrack No.

Number of the subrack where the BTS board is located Subrack number of ADD the XPU BSC6900 NSE(Man board datory) bound to the NSE

GBFD118609

IP Fault Detection Interval Based on Type BFD

0~254

MRFD210301

Configura tion Interval Managem Type ent

0~11

SRN

Subrack No.

Subrack number of ADD board to GBFDBSC6900 PBSL(Ma which Pb 111203 ndatory) signaling link belongs

O&M of BSC

Interval Type

0~11

SRN

Port Subrack No.

ADD BTSSFP MODE(O ptional) SET BTSFOR BIDTS(O ptional) SET BTSOML TS(Option al) SET BTSETH PORT(Op tional) ADD BSC6900 BTSPPPL NK(Optio nal) ADD BTSMPL NK(Optio nal) ADD BTSETH MA(Optio nal) ADD BTSETHL CMEP(Op tional) ADD BTSTOP

Number of the subrack GBFDwhere the 111202 port is located

O&M of BTS

Interval Type

0~254

SRN

Subrack No.

Subrack number of the ADD BSC6900 BTSCON GBFDBSC6900 board that NECT(Ma 111202 is ndatory) connecte d to the BTS Number of the OPR subrack BTSBRD GBFDBSC6900 where the PWR(Ma 111202 BTS ndatory) board is located

O&M of BTS

Interval Type

0~11

SRN

Subrack No.

O&M of BTS

Interval Type

SRN1

Number of the subrack ADD at one Subrack 1 SRCONP GBFDBSC6900 end of the No ATH(Man 111203 interdatory) subrack connectio n channel

O&M of BSC

Interval Type

0~11

SRN2

Number of the subrack ADD at the Subrack 2 SRCONP other end GBFDBSC6900 No ATH(Man of the 111203 datory) intersubrack connectio n channel

O&M of BSC

Interval Type

0~11

Subrack SRName name

Name of ADD the SUBRAC BSC6900 subrack K(Mandat to be ory) added

MRFD210301

Configura tion String Managem Type ent

None

SRNO

SET Number Tributary BTSTMA( BSC6900 of the No. Mandator tributary y)

GBFD111202

O&M of BTS

Interval Type

0~5

SRT

Subrack type

SET Type of BSC6900 CLK(Man the datory) subrack

MRFD210502

BSC/RNC Enumerati MPS, Clock on Type EPS, TCS

Sort SRTORD Order

EXP Sequence MRFDBSC6900 ALMLOG( of alarm 210304 Optional) records

DES(Des Faulty Enumerati cent), Managem on Type ASC(Asc ent ent)

SRVLW

Traffic local weight over the local NSVL. When this parameter is set to a large value, the NS is more ADD User Data likely to NSVLLO GBFDLoad BSC6900 select this CAL(Opti 118603 Weight IP point onal) according to the load sharing function of the NSVC link of the IP network, if the NS sends a data message. Traffic local weight over the remote NSVL. When this parameter is set to a larger value, the ADD User Data NS is NSVLRE GBFDLoad BSC6900 more MOTE(Op 118603 Weight likely to tional) select this IP point according to the load sharing function of the NSVC link of the IP network, if

Gb over IP

Interval Type

0~255

SRVLW

Gb over IP

Interval Type

0~255

Service SRVPRIP Priority OLICY Policy

SET BTSPSU BSC6900 FP(Option al)

SRVTYP Service E Type

ADD BTSABIS BSC6900 MUXFLO W(Manda tory)

The parameter specifies which type of service TRXs should be preferenti ally processe d when the PSU is faulty. Service type of the IP interface board. The service type can be CS speech, CS data, PS high priority, or PS low

GBFD111202 GBFD117804

O&M of GSM_PRI BTS OR(GSM Intelligent Traffic Shutdown Enumerati Prior), of TRX on Type UMTS_P Due to RIOR(UM PSU TS Traffic Failure Prior)

GBFD118605

IP QOS

CSVOICE (CS Voice), CSDATA( CS Data), Enumerati PSHIGHP on Type RI(PS High PRI), PSLOWP RI(PS Low PRI)

Penalty SSBQPU Level NISH after BQ HO

After a handover due to bad quality is successfu l, the penalty on the original serving cell is performe d within the SET "Penalty GCELLH Time after BSC6900 OFITPEN BQ HO": (Optional) the receive level of the original serving cell is decrease d by "Penalty Level after BQ HO", to prevent ping-pong handover

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

CPU SSCPUA occupanc SET VEUSAG y alarm BSC6900 CPUTHD( EALMTH clearance Optional) D threshold

CPU usage MRFDalarm 210304 clearance threshold

Faulty Interval Managem Type ent

20~99

SSCPUM AXUSAG EALMTH D

CPU SET occupanc BSC6900 CPUTHD( y alarm Optional) threshold

DSP SSDSPA occupanc SET VEUSAG y alarm BSC6900 CPUTHD( EALMTH clearance Optional) D threshold

CPU usage alarm threshold. When the CPU usage exceeds the threshold, a CPU usage alarm is reported. "CPU occupanc y alarm clearance threshold" is smaller than "CPU occupanc y alarm threshold" DSP usage alarm clearance threshold. When the DSP usage is lower than the threshold, the DSP usage alarm is cleared.

MRFD210304

Faulty Interval Managem Type ent

30~100

MRFD210304

Faulty Interval Managem Type ent

20~99

SSDSPM AXUSAG EALMTH D

DSP SET occupanc BSC6900 CPUTHD( y alarm Optional) threshold

SSLENS D

Filter SET Length for GCELLC BSC6900 TCH HMGAD( Level Optional)

DSP usage alarm threshold. When the DSP usage exceeds the threshold, a DSP usage alarm is reported. "DSP occupanc y alarm clearance threshold" is smaller than "DSP occupanc y alarm threshold" When the network receives measure ment reports, the measure ment values in several straight measure ment reports are filtered to reflect the radio operating environm ent for the sake of accuracy. This parameter specifies the number of successiv e measure ment reports

MRFD210304

Faulty Interval Managem Type ent

30~100

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~32

When the network receives measure ment reports, the measure ment values in several straight measure ment reports Filter SET are Length for GCELLC filtered to SSLENSI BSC6900 SDCCH HMGAD( reflect the Level Optional) radio operating environm ent for the sake of accuracy. The parameter specifies the number of successiv e measure ment reports STR BKP(Opti onal) ULD RSTINFO (Mandator y) Number Subsyste ADD of the SSN BSC6900 m No. XPUVLA subsyste N(Mandat m ory) LOD BRD(Opti onal) CMP TBLDATA No. of the subsyste m where ADD the Iur-g Subsyste GIURGC SSN BSC6900 common m No. ONN(Man connectio datory) n is establishe d

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~32

MRFD210301

Configura tion Interval Managem Type ent

0~7

MRFD211402

MBSC Interval Load Type Balancing

0~7

SSSN

EXP Start Sync BSC6900 ALMLOG( Serial No. Optional)

Penalty SSTAPU Level NISH after TA HO

SET GCELLH BSC6900 OFITPEN (Optional)

Start synchroni zation number of the alarm record After the time advancing handover is successfu l, the penalty on the original serving cell is performe d within the "Penalty Time after TA HO": the receive level of the original serving cell is decrease d by "Penalty Level after TA HO", to prevent ping-pong handover

MRFD210304

Faulty Interval Managem Type ent

1~214748 3646

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

ST

SET Start of StartTime BSC6900 TZ(Mand DST atory)

GBFD116101 MRFD210301

Support of Daylight Saving Compoun HOUR, Time d Type MIN, SEC Configura tion Managem ent

ST

Start Time

The operation time of the log record should be EXP after this GBFDBSC6900 LOG(Opti time. If 111203 onal) this parameter is not specified, the start time is not If the time mode is set to "DAILY_T ADD ", SUBTSK( "WEEKLY GBFDBSC6900 Mandator _T", or 111203 y) "MONTHL Y_T", you should set this parameter The operation time of the log record should be COL after this BSC6900 LOG(Opti time. If onal) this parameter is not specified, the start time is not Start time of the alarm EXP record. By BSC6900 ALMLOG( default, Optional) the start time is 00:00:00.

O&M of BSC

year, month, Compoun date, d Type hour, min, sec

ST

Start Time

O&M of BSC

Compoun hour, min d Type

ST

Start Time

GBFD111203 MRFD210305

O&M of year, BSC month, Compoun Security date, d Type Managem hour, min, ent sec

ST

Start Time

MRFD210304

Faulty Compoun hour, min, Managem d Type sec ent

ST

Start Time

Start time of the alarm STA record. By MRFDBSC6900 ALMLOG( default, 210304 Optional) the start time is 00:00:00.

Faulty Compoun hour, min, Managem d Type sec ent

ST

Start Time

A key parameter that indicates ADD the date GSMSCB and time GBFDBSC6900 (Mandator when the 113602 y) BSC6900 broadcast s cell message s EXP ALMLOG( Optional) BSC6900 STA ALMLOG( Optional) Start number of MRFDthe alarm 210304 record

year, Simplified Compoun month, Cell d Type day, hour, Broadcast min, sec

STARTAI Start D Alarm ID

Faulty Interval Managem Type ent

1~65535

STARTC BSHORT MSGFLO WCTRL

Prefer Variable Bitmap Code

Whether to preferenti ally use the variable bitmap code when encoding SET the BSCFCP frequency GBFDBSC6900 ARA(Opti in the 113701 onal) System Informatio n and encoding the FH frequency in the assignme nt or handover command

Frequenc y Hopping (RF Enumerati NO(No), hopping, on Type YES(Yes) baseband hopping)

STARTC HREQAR RIVALCT RL

CHAN REQ Arrival Control

SET BSCFCP BSC6900 ARA(Opti onal)

BLK STARTCI Start CIC BSC6900 ACIC(Ma C ndatory)

BLK STARTCI Start CIC BSC6900 PBCIC(M C andatory)

This parameter indicates whether the arrival of channel request message s is controlled It indicates the start CIC of the A interface CIC segment. When operation mode is set to OPC index, DPC group index, BSC ID, or CIC, It indicates the start CIC of the Pb interface CIC segment. If the search object mode is set to search by the specified range, the parameter is

GBFD111705

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

GBFD111803

A Interface Interval Circuit Type Managem ent

0~65535

GBFD111203

O&M of BSC

Interval Type

0~65535

StartDay DSTPA

This parameter specifies the start ADD date of a Prohibit BSCDST period Power GBFDBSC6900 PADATE( during Saving 111602 Mandator which the Start Day y) TRX Intelligent Shutdown feature is disabled.

TRX Power Interval Amplifier Type Intelligent Shutdown

1~31

When the environm ent temperatu re reaches the specified value of this parameter , the heater is Heater SET started. STARTH Startup BTSDHE In multi- GBFDEATTEM BSC6900 Temperat UBP(Opti mode 111202 P ure onal) scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter

O&M of BTS

Interval Type

-990~400

Prohibit Power StartMont Saving hDSTPA Start Month

This parameter specifies the start ADD month of BSCDST a period GBFDBSC6900 PADATE( during 111602 Mandator which the y) TRX Intelligent Shutdown feature is disabled. This parameter indicates SET whether BSCFCP the arrival GBFDBSC6900 ARA(Opti of paging 111705 onal) message s are controlled . This

JAN(Jan.) , FEB(Feb. ), MAR(Mar. ), TRX APR(Apr.) Power Enumerati , Amplifier on Type MAY(May Intelligent ), Shutdown JUN(Jun.) , JUL(Jul.), AUG(Aug. ), SEP(Sep)

STARTP Paging GARRIVA Arrival LCTRL Control

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

parameter indicates whether PS STARTP SET the arrival Resource SRESRE BSCFCP of PS GBFDREQ BSC6900 QARRIVA ARA(Opti resource 111705 Arrival LCTRL onal) request Control message s is controlled .

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

STARTS UBTS

SET Start Sub BTSFOR Timeslot BSC6900 BIDTS(O No. ptional)

Number of the GBFDstart sub- 111202 timeslot

O&M of BTS

Enumerati 0(0), 2(2), on Type 4(4), 6(6)

Fallback STARTTI Start ME Time

SET BTSFALL BSC6900 BACK(Op tional)

Time SET StartTime When the BSCDST TACloseT Function BSC6900 PA(Optio rxPA Is nal) Enabled

Time for which the BTS waits to start the fallback function after the OML is interrupte d. With this parameter , the BTS does not start the fallback function when the OML is interrupte This parameter specifies the start time for dynamical ly enabling the TRX Intelligent Shutdown feature each day.

GBFD510309

Group Call Interval Reliability Type Enhancin g

60~600

GBFD111602

TRX Power Compoun Amplifier hour, min d Type Intelligent Shutdown

STARTTS Start TS

It indicates BLK the start ATERE1T CIC of the GBFDBSC6900 1(Mandat Ater 111801 ory) interface CIC segment.

Ater Interface Interval 4:1 Type Multiplexi ng

8~255

STARTTS Start TS

It indicates the start CIC of the A interface CIC segment. When Operation mode is BLK set to GBFDBSC6900 AE1T1(M subrack 111803 andatory) number, slot number, port number, or CIC, the parameter is mandator y.

A Interface Interval Circuit Type Managem ent

1~31

Start STARTTS Timeslot No.

SET BTSFOR BSC6900 BIDTS(M andatory)

Number of the start timeslot

GBFD111202

O&M of BTS

Interval Type

1~31

STC

Whether to enable the smart temperatu re control mechanis m of the FMUA. Smart temperatu re control refers to the mechanis m Smart SET adopted Temperat BTSFMU by the GBFDBSC6900 ure ABP(Opti FMUA to 111202 Control onal) adjust the fan speed, and thus to regulate the temperatu re according to the environm ent temperatu re. In multi-

O&M of BTS

DISABLE D(Disable Enumerati d), on Type ENABLE D(Enable d)

STC

Whether to enable the smart temperatu re control mechanis m of the NFCB. Smart temperatu re control refers to the mechanis Smart SET m Temperat BTSNFC GBFDBSC6900 adopted ure BBP(Opti 111202 by the Control onal) NFCB to adjust the fan speed, and thus to regulate the temperatu re according to the environm ent

O&M of BTS

DISABLE D(Disable Enumerati d), on Type ENABLE D(Enable d)

STCIC

ADD Start CIC BSC6900 AE1T1(M andatory)

STCN

Out Port Cabinet No.

ADD BTSMONI BSC6900 TORTS(O ptional)

Number of the start CIC. The C/C of each E1/T1 timeslot can be calculated on the basis of this parameter . Assume that the start CIC is 100, the CIC of the E1 timeslots on the A interface will automatic ally be set to 100, 101, 102, 103, and so on. Assume that the CIC of an E1 timeslot is Number of the cabinet where the outgoing port of the BTS is located

GBFD111803

A Interface Interval Circuit Type Managem ent

0~65535

GBFD111202

O&M of BTS

Interval Type

0~62

STD

Start date. The ADD input Start Date BSC6900 OP(Mand format is atory) YYYY&M M&DD.

GBFD111203 MRFD210305

O&M of BSC year, Compoun Security month, d Type Managem day ent

STEP

Number of frequenci es measured STR in each Measure GBFDBSC6900 NCS(Man group ment Step 510901 datory) (excluding the frequenci es in the original BA table).

2G/3G Neighbori ng Cell Interval Automatic Type Optimizati on

1~32

STFLG

Satellite flag

ADD MTP3LN Satellite BSC6900 K(Optiona flag l)

GBFD111804

A Interface Protocol Process

NO(NO), Enumerati YES(YES on Type )

STIME

Start Time

STR GBFDBSC6900 BTSLOG( Start time 111202 Optional)

O&M of BTS

Compoun hour, min, d Type sec

STIRCAL EICC LOWED Allowed

Whether to enable the EICC algorithm. Enhanced Interferen ce Rejection Combinin g combines SET the GCELLS signals GBFDBSC6900 OFT(Opti received 115821 onal) by multiple antennas to obtain better signals. EICC is mainly used in high traffic network

EICC

Enumerati NO(No), on Type YES(Yes)

Stop SET Send SI STOPSI5 GCELLS 5/5bis/5te BSC6900 SWITCH OFT(Opti r after onal) Encrypt

SET STOPTIM Fallback BTSFALL BSC6900 E Stop Time BACK(Op tional)

STP

STP function switch

ADD BSC6900 N7DPC(O ptional)

This parameter specifies whether the sending of system informatio n 5, 5bis, and 5ter can be stopped on the SACCH on the SDCCH after the BTS issues a ciphering command . Time for which the BTS waits to stop the fallback function after the OML is set up. With this parameter , the BTS does not stop the fallback function when the OML is set up transiently Whether to enable the signaling point with the signaling transfer function

GBFD113521

A5/1 Encryptio Enumerati OFF(Off), n Flow on Type ON(On) Optimizati on

GBFD510309

Group Call Interval Reliability Type Enhancin g

60~300

GBFD111804

A Interface Protocol Process

Enumerati OFF(OFF on Type ), ON(ON)

STPN

Out-BTS Port No.

Number of the outgoing ADD port of the BTSMONI GBFDBSC6900 BTS TORTS(M 114701 where the andatory) monitorin g timeslot is located SET GCELLF BSC6900 REQSCA N(Optiona l) Start time of GBFDfrequency 112401 scanning

SemiPermane Interval nt Type Connectio n

0~23

STRTM

Start Time

Cell Compoun hour, min, Frequenc d Type sec y Scan

STSN

Out Port Slot No.

Number of the slot ADD where the BTSMONI GBFDBSC6900 outgoing TORTS(O 111202 port of the ptional) BTS is located Number of the ADD subrack BTSMONI where the GBFDBSC6900 TORTS(O outgoing 111202 ptional) port of the BTS is located

O&M of BTS

Interval Type

0~23

STSRN

Out Port Subrack No.

O&M of BTS

Interval Type

0~254

STSUBT S

Out-BTS Sub Timeslot No.

Number of the subADD timeslot BTSMONI GBFDBSC6900 on the TORTS(M 111202 outgoing andatory) port of the BTS

O&M of BTS

Interval Type

0~7

STT

Start Time

Start time. ADD The input BSC6900 OP(Mand format is atory) HH&MM& SS.

GBFD111203 MRFD210305

O&M of BSC Compoun hour, min, Security d Type sec Managem ent

STTS

Out-BTS Timeslot No.

Number of the ADD timeslot BTSMONI GBFDBSC6900 on the TORTS(M 111202 outgoing andatory) port of the BTS

O&M of BTS

Interval Type

1~31

STTYPE

SET BTSAUT Type of BTS Type BSC6900 ODLDAC the BTS. TINFO(O ptional)

GBFD111202

O&M of BTS

ID of SUBBSC slave TID BSC in TC Pool

ID of the BSC in the TC BLK pool GBFDBSC6900 ACIC(Ma where an 113726 ndatory) A interface circuit is blocked ID of the BSC in the TC ADD pool to GBFDBSC6900 AE1T1(M which an 113726 andatory) A interface E1/T1 is added Comman

BTS30(B TS30), BTS312( BTS312), BTS3001 C(BTS30 01C), BTS3001 CP(BTS3 001CP), BTS3002 C(BTS30 02C), BTS3012 A(BTS30 12A), Enumerati BTS3006 on Type A(BTS30 06A), BTS3012( BTS3012) , BTS3006 C(BTS30 06C), BTS3002 E(BTS30 02E), BTS3012 AE(BTS3 012AE), BTS3012 _II(BTS30 12 II),

TC Pool

Interval Type

1~15

ID of SUBBSC slave TID BSC in TC Pool

TC Pool

Interval Type

1~15

d string Comman that is STR d transpare GBFDSUBCMD BSC6900 BTSLOG( Paramete 111202 ntly Optional) r transmitte d to the BTS

O&M of BTS

String Type

None

Max ADD SUBFRA subframe BSC6900 IPMUX(O MELEN length[byt ptional) e]

ADD SUBFRA Max BTSABIS METHRE Subframe BSC6900 MUXFLO S Length W(Option al)

Maximum sub-frame length. This parameter indicates the maximum sub-frame length for multiplexi ng. If the length of a subframe exceeds this value, the subframe is not multiplexe d. Maximum sub-frame length. The data stream to be multiplexe d on the same multiplexi ng channel must be of the same type, and the length of the packet before multiplexi ng cannot exceed the maximum subframe length. If the length of a packet exceeds the maximum subframe

GBFD118604 GBFD118610

Abis MUX UDP MUX for Interval A Type Transmis sion

16~1023

GBFD118604

Abis MUX

Interval Type

16~1023

SUBID

Subtask ID

ADD SUBTSK( Mandator y) BSC6900 ADD SUBCMD (Mandator y)

Number of the GBFDscheduled 111203 subtask

O&M of BSC

Interval Type

1~50

Subnet SUBNET No

SET Subnet SUBNET( BSC6900 Number Mandator in a BSC y)

None

None

Interval Type

1~124,12 8~189

Sublink SET SUBRES Resource GCELLS PREEMP s BSC6900 OFT(Opti TFLG Preemptio onal) n Switch

SUBRES Sub Res PREEMP Preempt TFLG Flag

SET BTSFLEX BSC6900 ABISPAR A(Optiona l)

This parameter specifies whether the CS services preempt the sublink resources of PS services. Whether to allow the CS services to preempt the sublink resources of PS services when the Abis resources are

GBFD117301

Flex Abis

Enumerati NO(No), on Type YES(Yes)

GBFD117301

Flex Abis

NO(NO), Enumerati YES(YES on Type )

SUBTS

Sub Timeslot No.

Number SET of the subBTSOML GBFDBSC6900 timeslot TS(Mand 111203 on the atory) port

O&M of BSC

Enumerati 0(0), 2(2), on Type 4(4), 6(6)

SubVer

SubVersion No.of TMU

Subversion No. of the SET TMU BTSAUT board. It GBFDBSC6900 ODLDAC 111202 is TINFO(M configure andatory) d according to the Whether the CIC circuits in use on the A interface can be assigned. When this parameter is set to YES and the MSC assigns new calls SET to an OTHSOF ongoing A GBFDBSC6900 TPARA(O interface 111803 ptional) circuit, the original calls (that are occupying the circuit) are released, and the circuit is used by the new calls. When this parameter

O&M of BTS

Interval Type

0~65535

Support SupportA Apply pplyUsed Used A Cic Cic

A Interface Enumerati NO(No), Circuit on Type YES(Yes) Managem ent

Whether SUPPOR Use BackSET to use TBAKCLK up port for BSC6900 CLK(Opti Back-up 2SRC LINE2 onal) port for LINE2

MRFD210502

NO(NO), BSC/RNC Enumerati YES(YES Clock on Type )

Whether SUPPOR Use BackSET to use TBAKCLK up port for BSC6900 CLK(Opti Back-up SRC LINE1 onal) port for LINE1

MRFD210502

NO(NO), BSC/RNC Enumerati YES(YES Clock on Type )

Whether to add a simple cell broadcast message for broadcast ing the SUPPOR Support SET cell name. TCELLBR Cell GCELLS This GBFDBSC6900 OADCAS Broadcast BC(Optio parameter 113602 T Name nal) is only used for control broadcast ing cell name, not used for control CB service.

Simplified Enumerati NO(No), Cell on Type YES(Yes) Broadcast

Support SUPPOR High TDL5TS Multislot Class

Whether to support the high multislot class. High multislot class function enables a single MS to be allocated with a maximum SET of five BSCPSS timeslots BSC6900 OFTPAR on the A(Optiona uplink or l) downlink, thus improving the uplink or downlink throughpu t of a single MS. The BSS supports the MS with high multislot

GBFD113101 GBFD119402 GBFD119303 GBFD119501

PDCH Dynamic Adjustme nt MS High NOTSUP multislot PORT(No classes t Load Enumerati Support), Sharing on Type SUPPOR Adaptive T(Support Adjustme ) nt of Uplink and Downlink Channels

SUPPOR Support TDTM DTM

SET GCELLG BSC6900 PRS(Opti onal)

SUPPOR Support TEDA EDA

SET BSCPSS BSC6900 OFTPAR A(Optiona l)

Whether to support dual transfer mode (DTM). The DTM allows an MS to use the circuit switching service and the packet switching service at the same time. This function must be supported by the network side. If "Cell Extension Type" in the "ADD GCELL" command or "MOD GCELL" command is set to Whether to support EDA. Extended dynamic allocation (EDA) enables the MS to be allocated with more timeslots on the uplink, thus improving the uplink rate and helping to transmit large amounts of data on the uplink.

GBFD114151

DTM

UNSUPP ORT(Not Enumerati Support), on Type SUPPOR T(Support )

GBFD113101 GBFD119401 GBFD119303 GBFD119501

PDCH Dynamic Adjustme nt EDA(Exte nded NOTSUP Dynamic PORT(No Allocation t ) Enumerati Support), Load on Type SUPPOR Sharing T(Support Adaptive ) Adjustme nt of Uplink and Downlink Channels

Whether to support the enhanced DTM function. Comparin g to the DTM, the SET Support enhanced SUPPOR GCELLG Enhanced BSC6900 DTM TENDTM PRS(Opti DTM improves onal) the CS setup and release. During the CS service setup, the PS service is Whether Support the FE/GE FE/GE SupportIp SET SPAN BTS SpanBtsL BSC6900 BSSLS(O BTS supports Switch ptional) Local inter-BTS Switch local switching

GBFD114151

DTM

UNSUPP ORT(Not Enumerati Support), on Type SUPPOR T(Support )

GBFD117702

BTS Local Switch

Enumerati NO(No), on Type YES(Yes)

Support SupportT TFO FOCodec Codec Optimize Optimize

Support intracell handover to change the active speech version, then can SET increase BSCBASI GBFDBSC6900 the usage C(Optiona 115701 of l) TFO(Tan dem Free Operation ) to improve the speech quality.

TFO

NO(Not Enumerati Support), on Type YES(Sup port)

Whether to support the cell list in the common measure ment message s over the Iur-g interface. When this parameter is set to YES, the local BSC ADD SupptCell SupptCell MRFDcan BSC6900 GNRNC( List List 211404 handle Optional) the load informatio n of the cells in the cell list carried in the received common measure ment message s. In addition, the BSC can carry

MBSC Handover NO(No based on Enumerati Support), Load on Type YES(Sup Enhance port) ment

SVALUE

SVRIP

Minimum timeslots between two successiv e channel requests. After sending the access request, if the MS does not SET receive GCELLP S Value BSC6900 the RACH(Op response tional) message after waiting for the minimum timeslots between two successiv e channel requests, the MS resends the Server IP address used on the SGSN ADD side in the Server IP BSC6900 NSE(Man IP subnet datory) dynamic configurat ion procedure

GBFD119110

Access

T_12(12), T_15(15), T_20(20), T_30(30), T_41(41), T_55(55), Enumerati T_76(76), on Type T_109(10 9), T_163(16 3), T_217(21 7)

GBFD118603

Gb over IP

IP Address Type

None

Server UDP port number used on ADD the SGSN SVRPOR Server GBFDBSC6900 NSE(Man side in the T UDP Port 118603 datory) IP subnet dynamic configurat ion procedure

Gb over IP

Interval Type

0~65535

SW

Switch

SET ALMPOR BSC6900 T(Optiona l)

Operating state of the MRFDenvironm 210304 ent alarm port

CLOSE(C Faulty Enumerati LOSE), Managem on Type OPEN(O ent PEN)

SW

SW

If this parameter is set to "ON", you must set "OMU OMU SET automatic Automatic ASWPAR switchove BSC6900 Switchove A(Mandat r interval". r Switch ory) Otherwise , "OMU automatic switchove r interval" is not displayed. Switch for authentic ating objects. When the switch is enabled, the BSC system authentic SET ates the OBJAUT Switch BSC6900 BTS HSW(Ma objects of ndatory) the user; when the switch is disabled, the BSC system does not authentic ate the BTS SET BTSENV BSC6900 ALMPOR T(Mandat ory)

GBFD111203

O&M of BSC

Enumerati ON, OFF on Type

GBFD111203

O&M of BSC

Enumerati OFF(OFF on Type ), ON(ON)

SW

Switch

Whether to enable GBFDthe alarm 111202 port

O&M of BTS

CLOSE(C Enumerati lose), on Type OPEN(Op en)

SW

Power Switch

OPR Power BTSBRD BSC6900 switch PWR(Ma state. ndatory)

GBFD111202

O&M of BTS

ON(ON), Enumerati OFF(OFF on Type )

SWEEK

Start week

Weekday SET on which BSC6900 TZ(Mand DST atory) starts

GBFD116101 MRFD210301

SUN(Sun day), MON(Mo Support nday), of TUE(Tues Daylight day), Saving Enumerati WED(We Time on Type dnesday), Configura THU(Thur tion sday), Managem FRI(Frida ent y), SAT(Satu rday)

Switch

Port switch

SET SCUPOR BSC6900 T(Mandat ory)

State of the panel MRFDport 210301 switch

Configura tion Enumerati CLOSE, Managem on Type OPEN ent

SelfSWITCH healing Switch

SET SLFSLVS BSC6900 W(Manda tory)

Switch for the OMU None selfhealing

None

ON(ON), Enumerati OFF(OFF on Type )

Grace Protection Period Grace SET Switch Protection LICENSE determine MRFDSWITCH BSC6900 Period CTRL(Ma s whether 210403 Switch ndatory) to enter the grace protection period. Bfd SWITCH Protocol Switch Turn on SET or turn off BFDPRO GBFDBSC6900 the BFD TOSW(M 118609 protocol andatory) switch

License ON(ON), Enumerati Managem OFF(OFF on Type ent )

IP Fault BFD_OFF Detection Enumerati (OFF), Based on on Type BFD_ON( BFD ON)

Whether to enable the board parameter s to be configure d. If this parameter Alarm is set to Paramete SET "YES", r BTSALM GBFDSWITCH BSC6900 the user Configura PORT(Ma 111202 can set tion ndatory) board Enabled parameter s of the BTS. Otherwise , the user cannot set the board SET BTSETH BSC6900 PORT(Op tional) Whether to enable the 3ah function on the BTS port. GBFD115501 GBFD115502 GBFD115701

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

SWITCH3 3ah AH Switch

AMR FR AMR HR TFO

CLOSE(C Enumerati lose), on Type OPEN(Op en)

The field indicates whether the Switch ADD SWITCH primary primary IP SCTPLN GBFDBACKFLA BSC6900 path can address K(Optiona 118602 G be flag l) switched back when it is available. The associatio n is smoothly switched ADD over to SCTPLN the GBFDBSC6900 K(Optiona primary 118602 l) path after the number of heartbeat response s is

A over IP

NO(NO), Enumerati YES(YES on Type )

SWITCH Switch BACKHB back HB NUM number

A over IP

Interval Type

1~254

SET SS7PATC SwitchPar SwitchPar BSC6900 HSWITC ameter1 ameter1 H(Optiona l)

Set patch switch GBFDparameter 111203 1

O&M of BSC

Enumerati OFF(OFF on Type ), ON(ON)

SET SS7PATC SwitchPar SwitchPar BSC6900 HSWITC ameter10 ameter10 H(Optiona l)

Set patch switch GBFDparameter 111203 10

O&M of BSC

Interval Type

0~429496 7295

SET SS7PATC SwitchPar SwitchPar BSC6900 HSWITC ameter2 ameter2 H(Optiona l)

Set patch switch GBFDparameter 111203 2

O&M of BSC

Enumerati OFF(OFF on Type ), ON(ON)

SET SS7PATC SwitchPar SwitchPar BSC6900 HSWITC ameter3 ameter3 H(Optiona l)

Set patch switch GBFDparameter 111203 3

O&M of BSC

Enumerati OFF(OFF on Type ), ON(ON)

SET SS7PATC SwitchPar SwitchPar BSC6900 HSWITC ameter4 ameter4 H(Optiona l)

Set patch switch GBFDparameter 111203 4

O&M of BSC

Enumerati OFF(OFF on Type ), ON(ON)

SET SS7PATC SwitchPar SwitchPar BSC6900 HSWITC ameter5 ameter5 H(Optiona l)

Set patch switch GBFDparameter 111203 5

O&M of BSC

Enumerati OFF(OFF on Type ), ON(ON)

SET SS7PATC SwitchPar SwitchPar BSC6900 HSWITC ameter6 ameter6 H(Optiona l)

Set patch switch GBFDparameter 111203 6

O&M of BSC

Enumerati OFF(OFF on Type ), ON(ON)

SET SS7PATC SwitchPar SwitchPar BSC6900 HSWITC ameter7 ameter7 H(Optiona l)

Set patch switch GBFDparameter 111203 7

O&M of BSC

Interval Type

0~429496 7295

SET SS7PATC SwitchPar SwitchPar BSC6900 HSWITC ameter8 ameter8 H(Optiona l)

Set patch switch GBFDparameter 111203 8

O&M of BSC

Interval Type

0~429496 7295

SET SS7PATC SwitchPar SwitchPar BSC6900 HSWITC ameter9 ameter9 H(Optiona l)

Set patch switch GBFDparameter 111203 9

O&M of BSC

Interval Type

0~429496 7295

SWITCH Switch PORTNO Port

Number of the switching port. If "Link Attribute" is set to ADD "BBU", BTSSFP GBFDBSC6900 the MODE(O 111202 switching ptional) port must be configure d. The value ranges from 3 to

O&M of BTS

Interval Type

3~5

SWOP

Whether to enable Set SET the local Enable/Di BSC6900 OPSW(M user sable andatory) managem ent function

GBFD111203 MRFD210305

O&M of BSC Enumerati OFF(Off), Security on Type ON(On) Managem ent FIRST(Fir Support st), of SECOND Daylight (Second), Saving Enumerati THIRD(Th Time on Type ird), Configura FOURTH( tion Fourth), Managem LAST(Las ent t)

SWSEQ

Sequence Start SET of the week BSC6900 TZ(Mand start week sequence atory) of DST

GBFD116101 MRFD210301

BTS SYMOFF Symbol SET Offset

Symbol offset of the BTS set manually. After the offset informatio n of the BTS is collected, the symbol offset is SET adjusted. GBFDBSC6900 BTSAISS( Adjustme 118201 Optional) nt value = Collected symbol offset relative to the reference BTS (BTS symbol offset + BSC symbol offset).

SoftSynchroni Interval zed Type Network

0~2500

SYNCCA Sync SE case

Synchroni zation status. This parameter is used to identify ADD different GEXT3G GBFDBSC6900 3G cells. CELL(Ma 114302 This ndatory) parameter should be same with the configurat ion of 3G cells.

SyncCase GSM/TD1(Sync SCDMA Enumerati case 1), Interopera on Type SyncCase bility 2(Sync case 2)

Site synchroni zation method. AISS stands for the airSite SET interface SYNCME Synchroni BTSOTH soft BSC6900 THOD zation PARA(Op synchroni Method tional) zation method, and GPS stands for the GPS synchroni zation method.

GBFD117002 GBFD118201

IBCA (Interfere nce AISS(Air Based Interface Channel Software Enumerati Allocation Sync), on Type ) GPS(GPS SoftSynchroni Synchroni zation) zed Network

Synchroni Clock SET zation SYNMOD Synchroni BTSIPCL GBFDBSC6900 mode of E zation KPARA(M 118606 the IP Mode andatory) clock

Clock over IP

CONSYN (Consecut ive Synchroni Enumerati zing), on Type INTERSY N(Intermit tent Synchroni zing)

Interim synchroni zation period (in SET days). Days of SYNTIME BTSIPCL The BTS GBFDInter Sync BSC6900 DAY KPARA(O can re118606 Period ptional) initiate the synchroni zation only after the

Clock over IP

Interval Type

1~7

Interim synchroni zation period (in SET hours). Hours of SYNTIME BTSIPCL The BTS GBFDInter Sync BSC6900 HOUR KPARA(O can re118606 Period ptional) initiate the synchroni zation only after the Interim synchroni zation period (in minutes). SET The BTS BTSIPCL GBFDBSC6900 can reKPARA(O 118606 initiate the ptional) synchroni zation only after the period. Contact way of the Base MRFDStation 210301 Controller supplier

Clock over IP

Interval Type

0~23

Minutes SYNTIME of Inter MIN Sync Period

Clock over IP

Interval Type

0~59

Contact mode of SET SYSCON the BSC6900 SYS(Opti TACT manufact onal) urer

Configura tion String Managem Type ent

None

Descriptio System SET n of the SYSDES MRFDdescriptio BSC6900 SYS(Opti Base C 210301 n onal) Station Controller

Configura tion String Managem Type ent

None

SYSFLO WLEV

System flux threshold s correspon d to the system flux obtained based on message packets, CPU load, and FID queuing System SET load. The Flux GCELLH system Threshold BSC6900 OAD(Opti flux level for Load onal) is the HO current flux control level of the system. 0-11: There are 12 flow control levels. Where, 0 indicates the lowest

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0,8~11

SYSLOC System ATION Location

Location SET of the MRFDBSC6900 SYS(Opti Base 210301 onal) Station Controller

Configura tion String Managem Type ent

None

Whether sending the system informatio n type 10 message Send SET on the SysMsg1 System BSCBASI VGCS/VB GBFDBSC6900 0Allowed Message C(Optiona S TCH is 510301 10 Allow l) allowed. For detailed informatio n, see the 3GPP TS 44.018 9.1.50.

Public Voice Group Call Service

Enumerati NO(No), on Type YES(Yes)

Name of the Base SET Station SYSOBJE MRFDNE Name BSC6900 SYS(Opti Controller CTID 210301 onal) of Network Element Services provided SET by the MRFDBSC6900 SYS(Opti Base 210301 onal) Station Controller Timer T1, specifying the duration SET of BSSGPP GBFDBSC6900 monitorin ARA(Opti 119001 g the BVC onal) blocking (unblockin g) procedure CHG BTSPTU BSC6900 SHKTM( Optional) Value of the first timer for GBFDthe PTU 118601 handshak e

Configura tion String Managem Type ent

None

SYSSER System VICES services

Configura tion String Managem Type ent

None

T1

T1

Gb Interface Function

Interval Type

1000~300 00

T1

Time1

Abis over Interval IP Type

1~60

T10TMR

When the reception of a TFP causes unavailabi lity of a SET Signalling route, this MTP3TM GBFDroute set BSC6900 timer is R(Optiona 111804 test timer started to l) regularly check whether the route is recovered

A Interface Protocol Process

Interval Type

30000~60 000

T12TMR

SET Uninhibit MTP3TM BSC6900 ACK timer R(Optiona l)

T13TMR

Force uninhibit timer

SET MTP3TM BSC6900 R(Optiona l)

T14TMR

SET Inhibition MTP3TM BSC6900 ACK timer R(Optiona l)

This timer is a protection timer waiting for an uninhibit acknowle dgement message (LUA) from the peer end after an uninhibit message (LUN) is sent to the peer end. This timer is a protection timer waiting for a force uninhibit acknowle dgement message (LUA) from the peer end after a force uninhibit message (LFU) is sent to the peer This timer is a protection timer waiting for an inhibition acknowle dgement message (LIA) from the peer end after an inhibition message (LIN) is sent to the peer end.

GBFD111804

A Interface Protocol Process

Interval Type

800~1500

GBFD111804

A Interface Protocol Process

Interval Type

800~1500

GBFD111804

A Interface Protocol Process

Interval Type

2000~300 0

T17TMR

SET Link MTP3TM realignme BSC6900 R(Optiona nt timer l)

T1TMR

TimeSET control MTP3TM BSC6900 changeov R(Optiona er timer l)

T2

T2

SET BSSGPP BSC6900 ARA(Opti onal)

T2

Time2

CHG BTSPTU BSC6900 SHKTM( Optional)

This timer is started when a link fails to be started. The restart of the link is initiated after this timer When a normal changeov er cannot be initiated, services will be changed over to an alternativ e link after this timer expires to avoid disorder Timer T2, specifying the duration of monitorin g the procedure of resetting SIG BVC and PTP Value of the second timer for the PTU handshak e

GBFD111804

A Interface Protocol Process

Interval Type

800~1500

GBFD111804

A Interface Protocol Process

Interval Type

800~1200

GBFD119001

Gb Interface Function

Interval Type

1000~120 000

GBFD118601

Abis over Interval IP Type

1~60

T200

T200

Timer in the LAPD protocol. The value of the timer indicates the time when the SET LAPD link BTSRING waits for GBFDBSC6900 ATTR(Opt the 117801 ional) response or acknowle dgement frame after sending the command frame.

Ring Interval Topology Type

6~240

This parameter specifies the expiry value of timer T200 used for the FACCH/T SET CHF over T200FAC T200 GCELLC the Um GBFDBSC6900 CHF FACCH/F CTMR(Op interface. 111002 tional) For the function of timer T200 and the effect of the parameter , see the descriptio n of "T200 SDCCH".

Radio Link Interval Managem Type ent

1~255

This parameter specifies the expiry value of timer T200 used for the FACCH/T SET CHH over T200FAC T200 GCELLC the Um GBFDBSC6900 CHH FACCH/H CTMR(Op interface. 111002 tional) For the function of timer T200 and the effect of the parameter , see the descriptio n of "T200 SDCCH".

Radio Link Interval Managem Type ent

1~255

T200 T200SAC SACCH CH3 TCH SAPI3

This parameter specifies the expiry value of timer T200 used for the SACCH over the Um interface SET when the GCELLC GBFDBSC6900 TCH CTMR(Op 111002 supports tional) SAPI3 services. For the function of timer T200 and the effect of the parameter , see the descriptio n of "T200 SDCCH".

Radio Link Interval Managem Type ent

1~255

T200 T200SAC SACCH CHS SDCCH

This parameter specifies the expiry value of timer T200 used for the SACCH SET on the GCELLC GBFDBSC6900 SDCCH. CTMR(Op 111002 For the tional) function of timer T200 and the effect of the parameter , see the descriptio n of "T200 SDCCH".

Radio Link Interval Managem Type ent

1~255

T200 T200SAC SACCH CT0 TCH SAPI0

This parameter specifies the expiry value of timer T200 used for the SACCH over the Um interface SET when the GCELLC GBFDBSC6900 TCH CTMR(Op 111002 supports tional) SAPI0 services. For the function of timer T200 and the effect of the parameter , see the descriptio n of "T200 SDCCH".

Radio Link Interval Managem Type ent

1~255

T200SDC T200 CH SDCCH

This parameter specifies the timeout value of timer T200 used for the SDCCH over the Um interface. T200 SET prevents GCELLC the data GBFDBSC6900 CTMR(Op link layer 111002 tional) from deadlock during data transmissi on. The data link layer transform s the physical link that is vulnerabl e to errors into a sequential

Radio Link Interval Managem Type ent

1~255

T200 T200SDC SDCCH CH3 SAPI3

This parameter specifies the expiry value of timer T200 when the SDCCH supports SET SAPI3 GCELLC GBFDBSC6900 services. CTMR(Op 111002 For the tional) function of timer T200 and the effect of the parameter , see the descriptio n of "T200 SDCCH".

Radio Link Interval Managem Type ent

1~255

T203

T203

Timer in the LAPD protocol. The value of the timer SET indicates BTSRING the GBFDBSC6900 ATTR(Opt maximum 117802 ional) duration for no frame exchange in the LAPD link.

Fast Ring Interval Network Type Switch

1~10

T22TMR

SET Local MTP3TM inhibit test BSC6900 R(Optiona timer l)

T23TMR

SET Remote MTP3TM inhibit test BSC6900 R(Optiona timer l)

After a local link is inhibited, this timer is started to regularly check the managem ent states at both ends of After a remote link is inhibited, this timer is started to regularly check the managem ent states at both ends of the link.

GBFD111804

A Interface Protocol Process

Interval Type

180000~3 60000

GBFD111804

A Interface Protocol Process

Interval Type

180000~3 60000

T2TMR

SET Changeov MTP3TM er ACK BSC6900 R(Optiona timer l)

T3

T3

SET BSSGPP BSC6900 ARA(Opti onal)

This timer is a protection timer waiting for an extended changeov er acknowle dgement message (XCA) from the peer end after an extended changeov er order message (XCO) is sent to the peer Timer T3. T3 is started after the message SUSPEN D is received on the BSC side. T3 is stopped after the message SUSPEN D ACK is received.

GBFD111804

A Interface Protocol Process

Interval Type

1400~200 0

GBFD119001

Gb Interface Function

Interval Type

1000~100 00

T3

Time3

CHG BTSPTU BSC6900 SHKTM( Optional)

Value of the third timer for GBFDthe PTU 118601 handshak e

Abis over Interval IP Type

1~60

T3105

T3105

SET GCELLH BSC6900 OAD(Opti onal)

T3115

T3115

SET GCELLG BSC6900 SMR(Opti onal)

When the BTS sends physical informatio n to the MS, the BTS starts the timer T3105.If the timer T3105 expires before the BTS receives the SAMB frame from MS, the BTS resends physical informatio n to the MS and restarts the timer T3105. The maximum times for resending physical Timer for retransmit ting the VGCS UPLINK GRANT message

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

GBFD510302

Public Voice Interval Broadcast Type Service

1~255

T3168

T3168

T3168 is used to set the maximum duration for the MS to wait for the uplink assignme nt message. After the MS originates SET the uplink GCELLP TBF GBFDBSC6900 SBASE(O setup 114101 ptional) request by sending the packet resource request or the channel request in the packet uplink acknowle dge message,

GPRS

500ms(50 0ms), 1000ms(1 000ms), 1500ms(1 500ms), 2000ms(2 Enumerati 000ms), on Type 2500ms(2 500ms), 3000ms(3 000ms), 3500ms(3 500ms), 4000ms(4 000ms)

T3192

T3192

Duration of releasing the TBF after the MS receives the last data block. When the MS receives the RLC data block SET containing GCELLP the flag GBFDBSC6900 SBASE(O identifying 114101 ptional) the last data block and confirms that all the RLC data blocks in the TBF are received, the MS sends the packet downlink acknowle

GPRS

0ms(0ms) , 80ms(80 ms), 120ms(12 0ms), 160ms(16 Enumerati 0ms), on Type 200ms(20 0ms), 500ms(50 0ms), 1000ms(1 000ms), 1500ms(1 500ms)

T3212

T3212

This parameter specifies SET the length GCELLID GBFDBSC6900 of the LEBASIC( 110301 timer for Optional) periodic location update.

Location Interval Updating Type

0~255

T391

Timer on the DTE side, specifying the Paramete ADD duration GBFDr of DTE BSC6900 BC(Optio of 510002 [T391] nal) acknowle dging the sending BC link integrity.

Gb Over FR

Interval Type

5~30

T3TMR

TimeSET control MTP3TM BSC6900 changeba R(Optiona ck timer l)

T4

T4

SET BSSGPP BSC6900 ARA(Opti onal)

T4TMR

Changeov SET er ACK MTP3TM first BSC6900 R(Optiona attempt l) timer

When a normal changeba ck cannot be initiated, services will be changed back to a normal link only after this timer expires to avoid disorder of data. Timer T4. T3 is started after the message v is received on the BSC side. T4 is stopped after the message RESUME ACK is received. This timer is a protection timer waiting for a changeba ck acknowle dgement message (CBA) from the peer end after the first changeba ck declaratio n (CBD) is sent to the peer

GBFD111804

A Interface Protocol Process

Interval Type

800~1200

GBFD119001

Gb Interface Function

Interval Type

1000~100 00

GBFD111804

A Interface Protocol Process

Interval Type

800~1200

T5

T5

SET BSSGPP BSC6900 ARA(Opti onal)

T5TMR

Changeov SET er ACK MTP3TM second BSC6900 R(Optiona attempt l) timer

Timer T5. When the downlink TBF is set up, if the BSC side does not receive the valid RACAP, the BSC originates the radio access capability update flow and the timer T5 is started. After receiving the core network response, the timer is This timer is a protection timer waiting for a changeba ck acknowle dgement message (CBA) from the peer end after the second changeba ck declaratio n (CBD) is sent to the peer

GBFD119001

Gb Interface Function

Interval Type

1000~300 00

GBFD111804

A Interface Protocol Process

Interval Type

800~1200

T6

T6

Timer T6. The BSC sends the SGSN request to download the BSS PFC. When the QoS parameter is obtained, the timer is started. SET After the BSSGPP message GBFDBSC6900 ARA(Opti CREATE 119001 onal) _BSS_PF C is received, the timer is stopped. After the timer expires, the request is sent to start the procedure of downloadi

Gb Interface Function

Interval Type

1000~100 00

T8

T8

Timer T8. The BSC sends the SGSN request to download the BSS PFC. When the QoS parameter is obtained, the timer is started. SET After the BSSGPP message GBFDBSC6900 ARA(Opti MODIFY_ 119001 onal) BSS_PFC _ACK is received, the timer is stopped. After the timer expires, the request is sent to start the procedure of downloadi This timer

Gb Interface Function

Interval Type

1000~100 00

T8TMR

is started when a transmissi on prohibited Transmis SET message sion MTP3TM (TFP) is GBFDprohibited BSC6900 R(Optiona sent. The 111804 inhibition l) TFP will timer not be sent any more during the running of this timer.

A Interface Protocol Process

Interval Type

800~1200

SET Filter TAFLTLE GCELLH Length for BSC6900 N OFITPEN TA (Optional)

SET TAFORU TA for UO GCELLH OHOALL HO BSC6900 OIUO(Opt OW Allowed ional)

When the network receives measure ment reports, the measure ment values in several straight measure ment reports are filtered to reflect the radio operating environm ent for the sake of accuracy. This parameter specifies the number of measure ment reports sampled Whether the TA is used as a decisive condition for the concentric cell handover

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~31

GBFD113201

Concentri Enumerati NO(No), c Cell on Type YES(Yes)

TAHOEN

TA HO Allowed

Whether to enable the time advance (TA) handover. The TA handover determine s whether the timing advance (TA) is higher than the SET predefine GCELLH d TA BSC6900 OBASIC( threshold. Optional) When the TA is higher than the predefine d TA threshold, a TA handover is triggered. The TA is calculated based on the distance

GBFD110601 GBFD510501

HUAWEI I Handover Enumerati NO(No), HUAWEI on Type YES(Yes) II Handover

TAHYST

One of the parameter s that determine the coverage of the OL subcell and UL subcell. When "Enhance d Concentri SET c TA GCELLH Allowed" GBFDHysteresi BSC6900 OIUO(Opt is set to 113201 s ional) OFF, "TA Hysteresi s", "RX_LEV Threshold ", "RX_LEV Hysteresi s", "RX_QUA L Threshold ", and "TA Threshold " determine

Concentri Interval c Cell Type

0~255

TA HO TALASTT Valid IME Time

The P/N criterion must be met for triggering a TA handover. That is, the TA handover can be triggered ADD only if P G2GNCE measure GBFDBSC6900 LL(Option ment 510501 al) reports among N measure ment reports meet the triggering conditions . This parameter correspon ds to P in the P/N

HUAWEI Interval II Type Handover

1~16

TALIMIT

An emergenc y handover is SET triggered TA GCELLH when TA BSC6900 Threshold OEMG(O is greater ptional) than or equal to the value of this parameter .

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

Talker TALKERI Info NFINT Interval

This parameter specifies the interval of broadcast ing the speech data of the talker on the downlink group call channel that is SET controlled GCELLG GBFDBSC6900 by the SMR(Opti 510306 BTS. onal) When the parameter is set to 0, the BTS (instead of the BSC6900 ) performs the broadcast ing with the default interval

Talker Interval Identificati Type on

0~255

When the network receives measure ment reports, the measure ment values in several straight measure ment reports TA Filter SET are TASIGST Length for GCELLH filtered to BSC6900 RFLTLEN SDCCH OFITPEN reflect the Level (Optional) radio operating environm ent for the sake of accuracy. This parameter specifies the number of measure ment reports sampled for ADD AISSCFG (Mandator y) ADD NCELL(M andatory) COL Unique SYNCINF identifier O(Mandat of the Um AISS ory) interface TASKIDX Task BSC6900 SET software Index BTSEXC synchroni URSION( zation Mandator task y) SET BSCSYN COFF(Ma ndatory) COL BSCSYN CINFO(M

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~31

GBFD118201

SoftSynchroni Interval zed Type Network

0~7

TA HO TASTATT Watch IME Time

The P/N criterion must be met for triggering a TA handover. That is, the TA handover can be triggered ADD only if P G2GNCE measure GBFDBSC6900 LL(Option ment 510501 al) reports among N measure ment reports meet the triggering conditions . This parameter correspon ds to N in the P/N

HUAWEI Interval II Type Handover

1~16

One of the parameter s that determine the coverage of the OL subcell and UL subcell. When "Enhance d Concentri SET c TATHRE TA GCELLH Allowed" GBFDBSC6900 S Threshold OIUO(Opt is set to 113201 ional) OFF, "TA Hysteresi s", "RX_LEV Threshold ", "RX_LEV Hysteresi s", "RX_QUA L Threshold ", and "TA Threshold " determine

Concentri Interval c Cell Type

0~255

TAVGT

Filter period of the signal strength in the packet transmissi on mode of the MS. The MS in the packet transmissi on mode measures SET the GCELLP downlink GBFDT_AVG_T BSC6900 SPWPAR signal 119115 A(Optiona strength. l) This parameter is used to calculate the Cn value of the MS output power. This parameter specifies the relation between

Power Control

Interval Type

0~25

TAVGW

T_AVG_ W

Filter period of the signal strength in the packet idle mode of the MS. The MS in the packet idle mode measures SET the GCELLP downlink GBFDBSC6900 SPWPAR signal 119115 A(Optiona strength. l) This parameter is used to calculate the Cn value of the MS output power. This parameter specifies the relation

Power Control

Interval Type

0~25

TB

Number of the output segment 1: Segment 1 describes the basic informatio n of the equipmen t. 2: Segment 2 Output EXP describes GBFDSegment BSC6900 DEVFILE( 111203 the No Optional) connectio n informatio n. 3: Segment 3 describes the module informatio n. 4: Segment 4 describes

O&M of BSC

Interval Type

1~12

TB

EXP Output BTSDEV Segment BSC6900 FILE(Opti No. onal)

TBS

Try SET Switching BTSOML BSC6900 Duration BACKUP( Time Optional)

Output Segment No. 1: Segment 1 describes the basic informatio n of the equipmen t. 2: Segment 2 describes the connectio n informatio n. 3: Segment 3 describes the module informatio n. 4: Segment 4 describes the Maximum time in which the BTS attempts to set up the OML after swapping the main and backup OMLs. If the BTS fails to set up the OML within this time, the BTS swaps the main and backup OMLs again.

GBFD111202

O&M of BTS

Interval Type

1~12

GBFD113728

OML Backup

Interval Type

30~300

TBS

TC

The BTS repeatedl y attempts to connect to port 0 or port 1 after the Ring I Try SET switchove Rotating BTSRING r. If the BSC6900 Duration ATTR(Opt connectio Time ional) n on one port fails within the time specified by this parameter , the BTS tries to connect Test code for the MTP3 link. After the successfu l test, the link can be used for carrying signaling services. If the test fails, the ADD MTP3 MTP3LN periodicall Test code BSC6900 K(Optiona y sends l) the fault locating command until the operation is successfu l. When the link is deleted or deactivate d, the system stops to send the fault

GBFD117801

Ring Interval Topology Type

60~300

GBFD111804

A Interface Protocol Process

Interval Type

1~254

TC

Tc

Timer Tc, specifying the interval for the BVC and MS to send flow control message s. When this parameter is set to a smaller SET value, the BSSGPP BVC and GBFDBSC6900 ARA(Opti the MS 119001 onal) send flow control message s in a shorter time, which allows the SGSN can use the latest flow control parameter to improve

Gb Interface Function

Interval Type

1000~100 00

TCC

Temperat ure compens ation coefficient . This parameter defines the charging voltage increase or decrease Temperat unit of ure SET each Compens BTSAPM battery GBFDBSC6900 ation UBP(Opti when the 111202 Coefficien onal) ambient t temperatu re of the battery varies with the reference temperatu re regulated by the vendor by 1 degree Celsius. See the vendor

O&M of BTS

Interval Type

0~500

TCCRCAl TC CRC lowed Allowed

This parameter specifies the cyclic redundan cy check (CRC) switch, which can be set to On or Off. SET The value BSCBASI of this BSC6900 C(Optiona parameter l) determine s whether check is performe d on the TRAU frame between the BSC6900 and the BTS.

GBFD111203 GBFD113726

O&M of BSC TC Pool

Enumerati OFF(Off), on Type ON(On)

Whether to allow the cell to dynamical ly change a channel from full rate to half rate or from half rate to full rate. If this parameter SET is set to TCH Rate TCHAJFL GTRXDE YES, the GBFDAdjust BSC6900 AG V(Optiona conversio 113402 Allow l) n is allowed; if the parameter is set to NO, the conversio n is not allowed and the changed channel is restored to the previous rate If the current channel seizure ratio reaches or exceeds this value, TCH SET the halfTCHBUS Traffic GCELLC rate TCH GBFDBSC6900 YTHRES Busy HMGAD( is 111005 Threshold Optional) assigned preferenti ally; otherwise, the fullrate TCH is assigned preferenti ally.

Dynamic Adjustme nt Enumerati NO(No), Between on Type YES(Yes) FR and HR

Enhanced Channel Interval Assignme Type nt Algorithm

0~100

When a call drops on the TCH, the correspon ding TCH call drop counter is increment DL FER SET TCHDRO ed by one Threshold GCELLO GBFDPSTATDL BSC6900 if the DL for TCH THEXT(O 111004 FER FER Call Drop ptional) carried in the last MR is greater than the value of this parameter .

Radio Dedicated Interval Channel Type Managem ent

0~1000

When a call drops on the TCH, the correspon ding TCH call drop counter is increment DL Level SET ed by one TCHDRO Threshold GCELLO if the GBFDPSTATDL BSC6900 for TCH THEXT(O downlink 111004 LEV Call Drop ptional) level carried in the last MR is lower than the value of this parameter .

Radio Dedicated Interval Channel Type Managem ent

0~63

When a call drops on the TCH, the correspon ding TCH call drop counter is increment DL SET ed by one TCHDRO Quality GCELLO if the GBFDPSTATDL Threshold BSC6900 THEXT(O downlink 111004 QUAL for TCH ptional) quality Call Drop carried in the last MR is greater than the value of this parameter .

Radio Dedicated Interval Channel Type Managem ent

0~70

When a call drops on the TCH, the correspon ding TCH call drop counter is increment UL FER SET TCHDRO ed by one Threshold GCELLO GBFDPSTATUL BSC6900 if the UL for TCH THEXT(O 111004 FER FER Call Drop ptional) carried in the last MR is greater than the value of this parameter .

Radio Dedicated Interval Channel Type Managem ent

0~1000

When a call drops on the TCH, the correspon ding TCH call drop counter is increment UL Level SET ed by one TCHDRO Threshold GCELLO if the GBFDPSTATUL BSC6900 for TCH THEXT(O uplink 111004 LEV Call Drop ptional) level carried in the last MR is lower than the value of this parameter .

Radio Dedicated Interval Channel Type Managem ent

0~63

When a call drops on the TCH, the correspon ding TCH call drop counter is increment UL SET ed by one TCHDRO Quality GCELLO if the GBFDPSTATUL Threshold BSC6900 THEXT(O uplink 111004 QUAL for TCH ptional) quality Call Drop carried in the last MR is greater than the value of this parameter .

Radio Dedicated Interval Channel Type Managem ent

0~70

Min TCHHOM Interval ININTV for TCH Hos

After a new TCH is assigned to an MS, the MS can be handed over to another channel SET only if the GCELLH BSC6900 time OCTRL(O during ptional) which the MS occupies the TCH is longer than the period specified by this parameter .

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~60

Maximum number of discarded SET MRs TCHMRC TchMrCut GCELLP allowed GBFDBSC6900 UTNUM Num WR3(Opti on the 117601 onal) TCH in a power control period

HUAWEI III Power Interval Control Type Algorithm

0~10

Whether the TCH rate type uses the MSC strategy or BSC strategy. When this parameter is set to NO and the MSC policy is used, the SET BSC TCHRAT TCH Rate OTHSOF preferenti GBFDBSC6900 EMODIFY Modify TPARA(O ally 111005 ptional) selects full-rate or half-rate channels based on the rate type carried by the MSC in the assignme nt or incoming BSC handover request. This parameter specifies the SET TCHTIME TCH Time interval at GCELLS GBFDHOPERI Handover BSC6900 which the OFT(Opti 113521 OD Period speech onal) service on a TCH is handed over.

Enhanced Channel Enumerati NO(No), Assignme on Type YES(Yes) nt Algorithm

A5/1 Encryptio Interval n Flow Type Optimizati on

1~600

This parameter specifies whether SET to perform TCHTIME TCH Time GCELLS periodic GBFDHOSWIT Handover BSC6900 OFT(Opti intra-cell 113521 CH Switch onal) handover for speech services on TCH.

A5/1 Encryptio Enumerati OFF(Off), n Flow on Type ON(On) Optimizati on

Threshold for determini ng that the underlaid subcell is busy. The BSC assigns channels in the underlaid subcell to the MS in Tch TCHTRIB SET a Traffic USYUND GCELLC concentric GBFDBusy BSC6900 ERLAYTH HMGAD( cell. 113201 Underlay R Optional) When Threshold "Allow Rate Selection Based on Overlaid/ Underlaid Subcell Load" is set to YES, halfrate channels are assigned if the

Concentri Interval c Cell Type

0~100

Tch TCHTRIC SET Traffic BUSYOV GCELLC Busy BSC6900 ERLAYTH HMGAD( Overlay R Optional) Threshold

TCLEN

ADD Test code MTP3LN BSC6900 length K(Optiona l)

The BSC assigns channels in the overlaid subcell to the MS in a concentric cell. If the channel seizure ratio of overlaid subcell is greater than the value of this parameter , half-rate channels are assigned. Otherwise , full-rate channels are assigned. Channel seizure ratio = (Num. of busy code Test length of the signaling link. By default, the value is 10.

GBFD113201

Concentri Interval c Cell Type

0~100

GBFD111804

A Interface Protocol Process

Interval Type

1~15

Mode of TC. SEPERA TE_PRIN CIPAL: Specifies that the MTP3 link is configure d for the primary BSC in the case of BM/TC ADD separated MTP3LN configurat GBFDTCMODE TC mode BSC6900 K(Mandat ion mode. 111804 ory) SEPERA TE_SUB ORDINAT E: Specifies that the MTP3 link is configure d for the slave BSC in the case of BM/TC separated configurat Mute TCMUTE Detect DETECT Class1 FLAG Switch Whether SET to enable GCELLS GBFDBSC6900 the classOFT(Opti 111203 1 mute onal) detection. ADD BTSRXU CHAIN(M andatory) BSC6900 CBN BTSRXU CHAIN(M andatory) Number of the cabinet where the GBFDmain 111202 board of the RXU ring is located Number

A Interface Protocol Process

SEPERA TE_PRIN CIPAL(Pri ncipal BSC), SEPERA TE_SUB ORDINAT E(Subordi nate Enumerati BSC), on Type TOGETH ER(BSC/ TC Together) , SEPERA TE_BSC_ INTERFA CE(BSC Interface)

O&M of BSC

DISABLE( DISABLE) Enumerati , on Type ENABLE( ENABLE)

TCN

Tail Cabinet No.

O&M of BTS

Interval Type

0~62

TCPN

TC Port No

of the TC port ADD where ATERCO BSC6900 one end None NPATH(M of the andatory) ATER connectio n channel

None

Interval Type

0~335

TCPOOLI TC Pool D ID

SET BSCBASI BSC6900 C(Mandat ory)

TCSN

TC Slot No

ADD ATERCO BSC6900 NPATH(M andatory)

If you enable the TC pool function when configurin g the basic informatio GBFD113726 n of the BSC6900, you need to enter the TC Pool ID. The ID must be unique in the entire Number of the TC slot where one end of the None ATER connectio n channel is located Number

TC Pool

Interval Type

0~4095

None

Interval Type

0~5,8~27

TCSRN

TC Subrack No

of the TC subrack ADD where ATERCO one end BSC6900 None NPATH(M of the andatory) ATER connectio n channel is located

None

Interval Type

0~11

TCTYPE

The type of TC resource

The type of TC resource GTC: TC resources that support normal voice coding/de coding and packet conversio n SET UTC: TC TCTYPE( MRFDBSC6900 resources Mandator 210301 that y) support only the optimized handover on the Iurg interface ITC: TC resources that support only the dual-stack function on the A

GTC(GTC Configura ), tion Enumerati UTC(UTC Managem on Type ), ent ITC(ITC)

Input mode of the BA table. In auto mode, the system fills in the BA1 and BA2 tables based on the adjacent relation of SET cells. In GCELLID TDDBA1T TDD BA1 GBFDmanual BSC6900 LETDDB AG Input Tag mode, the 114302 A1(Mand user atory) maintains the BA table. If the adjacent relation of cells is modified, for example, a neighbori ng cell is added or a cell is Whether the FDD BA2 table is generated SET automatic GCELLH TDDBA2T TDDBA2 ally MRFDBSC6900 OTDDBA AG Input Tag according 210301 2(Mandat to the ory) neighbori ng relation or typed manually.

GSM/TDAUTO(Au SCDMA Enumerati to), Interopera on Type Manual(M bility anual)

Configura AUTO(Au tion Enumerati to), Managem on Type Manual(M ent anual)

SET TDD GCELLC TDDCELL Reporting BSC6900 CUTRAN OFF Offset SYS(Opti onal)

SET TDDCELL TDD Cell GCELLC RESELDI Reselect BSC6900 CUTRAN V Diversity SYS(Opti onal)

When the priority of a TDD cell is ranked, the value of this parameter is added to the receive level of the TDD cell in the measure ment report. The values of this parameter correspon d to the following decibel values: 0: 0 dB A TDD cell can become a candidate cell only when the average receive level of the TDD cell is greater than the TDD Cell Reselect Diversity of the serving cell. The value of this parameter correspon ds to the following decibel value: 0: negative infinity 1: -28 dB 2: -24 dB ...

GBFD114302

GSM/TDSCDMA Interval Interopera Type bility

0~7

GBFD114302

GSM/TDSCDMA Interval Interopera Type bility

0~15

Threshold for determini ng whether the MR about a TDD cell is valid. The measure ment report is valid if the receive SET level of TDD GCELLC TDDCELL the TDD GBFDReporting BSC6900 CUTRAN THRED cell in the 114302 Threshold SYS(Opti measure onal) ment report is greater than the value of this parameter . After the valid measure ment report is filtered, the TDD cell joins This parameter specifies whether SET to activate GCELLID the GBFDBSC6900 LETDDB diversity 114302 A1(Mand mode on atory) the common channel of a 3G cell.

GSM/TDSCDMA Interval Interopera Type bility

0~7

TDDDIVE Diversity RSITY

GSM/TDSCDMA Interval Interopera Type bility

0~1

SET GCELLID TDDDLU DL BSC6900 LETDDB ARFAN UARFAN A1(Mand atory)

TDD MI SET TDDMIO System GCELLC PTIMIZE Informatio BSC6900 CUTRAN DALLOW n SYS(Opti ED Optimized onal)

Downlink frequency of frequency 1 in table 3GBA2. This parameter indicates the detected downlink frequency in the 3G adjacent cell list in speech. The parameter is delivered in the system informatio n 2QUTER/ This parameter specifies whether the TDD MI system informatio n optimized function is enabled. When this parameter is set to NO and "TDD System Informatio n Optimized Allowed" is set to YES, the MI system informatio n issued in the TDD scenario does not carry neighbori ng cell scramblin

GBFD114302

GSM/TDSCDMA Interval Interopera Type bility

0~16383

GBFD114302

GSM/TDSCDMA Enumerati NO(No), Interopera on Type YES(Yes) bility

TDD MI SET System GCELLC TDDMIPR INFO BSC6900 CUTRAN OHIBIT Broadcast SYS(Opti ing onal) Prohibit

PS TDD ADD TDDRSC RSCP GEXT3G PQUALT BSC6900 Quality CELL(Opt HRSH Threshold ional)

This parameter specifies whether to send the system informatio n MI which contains the 3G neighbori ng cell informatio n in the TDD neighbori ng cell. The value YES(YES ) indicates that the MI is sent, and the value NO(NO) indicates Minimum RSCP quality threshold that the TDD 3G candidate cell must reach

GBFD114302

GSM/TDSCDMA Enumerati NO(No), Interopera on Type YES(Yes) bility

GBFD114302

GSM/TDSCDMA Interval Interopera Type bility

0~63

TDD cell parameter ID. The ID is used to distinguis h terminals or cells. This parameter is used after spread spectrum. Therefore SET , it does Cell GCELLID TDDSCR GBFDnot Paramete BSC6900 LETDDB AMBLE 114302 change r ID A1(Mand the atory) bandwidth of signals, but only distinguis hes the signals from different sources. Through scramblin g, multiple transceive rs can use the

GSM/TDSCDMA Interval Interopera Type bility

0~127

Cell parameter ID of a TDD cell. The cell parameter ID distinguis hes between MSs or cells. It is used after spread spectrum. SET Therefore Cell GCELLH TDDSCR MRFD, it Paramete BSC6900 OTDDBA AMBLE distinguis 210301 r ID 2(Mandat hes ory) between the signals from different sources, but not the changes in the bandwidth of signals. Through scramblin g, multiple

Configura tion Interval Managem Type ent

0~127

TDDSIOP TIMIZED ALLOWE D

TDD SET System GCELLC Informatio BSC6900 CUTRAN n SYS(Opti Optimized onal) Allowed

TDDSYN Sync CCASE Case

SET GCELLID LETDDB A1(Mand atory) BSC6900 SET GCELLH OTDDBA 2(Mandat ory)

This parameter specifies whether to optimize the system informatio n 2Quater and MI of the TDD neighbori ng cell. That is, to add an FDD neighbori ng cell informatio n before the TDD neighbori ng cell informatio n to solve the compatibil ity problem SyncCase in the TDDBA1 table. This parameter determine s the synchroni zation status. Value 0 indicates Sync case 1 and value 1 indicates Sync case 2. This parameter is used to

GBFD114302

GSM/TDSCDMA Enumerati NO(No), Interopera on Type YES(Yes) bility

GBFD114302

GSM/TDSCDMA Interval Interopera Type bility

0~1

If the ratio of available TDM Congestio ADD bandwidth TDMCON n clear TRMLOA GBFDBSC6900 is greater GCLRTH remain DTH(Opti 118605 than this ratio onal) value, congestio n control is the ratio If of available TDM bandwidth is less than or equal to this value, congestio n control is Each subrack has six TDM port numbers, ranging from 0 to 5. Subrack 1 TDM Port No. refers to the TDM port number on subrack 1 of the intersubrack connectio

IP QOS

Interval Type

0~100

ADD Congestio TDMCON TRMLOA n remain BSC6900 GTH DTH(Opti ratio onal)

GBFD118605

IP QOS

Interval Type

0~100

TDMN1

ADD Subrack 1 SRCONP TDM Port BSC6900 ATH(Man No datory)

GBFD111203

O&M of BSC

Interval Type

0~5

TDMN2

Each subrack has six TDM numbers, ranging from 0 to 5. ADD Subrack 2 Subrack 2 SRCONP TDM Port GBFDTDM Port BSC6900 ATH(Man No. refers 111203 No datory) to the TDM number on subrack 2 of the intersubrack connectio Terminal endpoint ADD ID of the GBFDBSC6900 PBSL(Opt Pb 111203 ional) signaling link

O&M of BSC

Interval Type

0~5

TEI

TEI

O&M of BSC

Interval Type

0~127

Enable ADD Temperat TEMP_M Temperat MRFDBSC6900 EMU(Opti ure alarm ASK ure Alarm 210304 onal) switch Reporting

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

Upper ADD TEMP_T Limit of BSC6900 EMU(Opti HD_HIGH Temperat onal) ure Alarm

Upper limit of MRFDtemperatu 210304 re

Faulty String Managem Type ent

None

Lower ADD TEMP_T Limit of BSC6900 EMU(Opti HD_LOW Temperat onal) ure Alarm

Lower limit of MRFDtemperatu 210304 re

Faulty String Managem Type ent

None

TEMPAL ARMTHR ESHOLD H

Upper ENV TEMP Alarm

When the environm ent temperatu re of the APMU is greater than the value of this parameter , the BTS reports an alarm. For the APMU SET of the nonBTSAPM EPS4815 MRFDBSC6900 UBP(Opti type, the 210304 onal) minimum value of the parameter is -490. In multimode scenario, the value of this parameter in one mode must be the same as the

Faulty Interval Managem Type ent

500~1000

TEMPAL ARMTHR ESHOLD H

Upper ENV TEMP Alarm

When the environm ent temperatu re is greater than the value of this parameter , the BTS reports an alarm. SET In multiBTSDPM mode MRFDBSC6900 UBP(Opti scenario, 210304 onal) the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another

Faulty Interval Managem Type ent

490~1000

TEMPAL ARMTHR ESHOLD L

Lower ENV TEMP Alarm

When the environm ent temperatu re of the APMU is less than the value of this parameter , the BTS reports an alarm. For the APMU of the nonSET EPS4815 BTSAPM type, the MRFDBSC6900 UBP(Opti maximum 210304 onal) value of the parameter is 990. In multimode scenario, the value of this parameter in one mode must be the same as the value of

Faulty Interval Managem Type ent

500~1000

TEMPAL ARMTHR ESHOLD L

Lower ENV TEMP Alarm

SET BTSDPM BSC6900 UBP(Opti onal)

Coefficien SET TEMPCO t of Temp BTSDPM MPENSA BSC6900 Compens UBP(Opti TECOEF ation onal)

When the environm ent temperatu re is less than the value of this parameter , the BTS reports an alarm. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode. Change value of the floating charge voltage of the storage battery when the temperatu re of the storage battery changes by 1 degree

MRFD210304

Faulty Interval Managem Type ent

-500~990

GBFD111202

O&M of BTS

Interval Type

0~5000

Cell SAV Descriptio TEMPLAT Template GCELLTE MRFDBSC6900 n of a cell EDESC Descriptio MPLATE( 210301 template. n Optional)

Configura tion String Managem Type ent

None

EXP Cell GCELLTE TEMPLAT Template BSC6900 MPLATE( EID Index Mandator y)

SAV Cell TEMPLAT GCELLTE Template BSC6900 EID MPLATE( Index Optional)

ADD GCELL(O ptional) ADD BTSAUT OPLAN(O ptional) EXP GCELLTE Cell TEMPLAT MPLATE( Template BSC6900 ENAME Mandator Name y) SAV GCELLTE MPLATE( Mandator y) ADD GCELLQ UICKSET

This parameter specifies the index number of a cell template. Each template is numbered uniquely in a BSC6900. This parameter specifies the index number of a cell template. Each template is numbered uniquely in a BSC6900.

MRFD210301

Configura tion Interval Managem Type ent

1~65535

MRFD210301

Configura tion Interval Managem Type ent

32768~65 535

Name of a cell template, uniquely MRFDidentifying 210301 a cell template in a BSC6900.

Configura tion String Managem Type ent

None

Temp Of TEMPOF SET High HIGHTE BTSAPM Temp. BSC6900 MPLOAD UBP(Opti Load PWROFF onal) Power Off

TEMPOF LOWTEM PLOADP WROFF

Low Temperat SET ure Start BTSAPM BSC6900 Load UBP(Opti Power Off onal) Temp.

When the temperatu re of the BTS cabinet is greater than the value of this parameter , the TRX is powered off. TRX power-off temperatu re threshold. If the temperatu re of the BTS cabinet is less than the value of this parameter while "Low Temperat ure Startup Allowed" is set to "Yes", the TRX is powered

GBFD111202 GBFD111601

O&M of BTS BTS Interval Power Type Managem ent

50~70

GBFD111202

O&M of BTS

Interval Type

-400~0

TEMPOF LOWTEM PLOADP WROFF

Low Temperat SET ure Start BTSDPM BSC6900 Load UBP(Opti Poweroff onal) Temp.

TER SET Indicator TER2INDI OTHSOF of System BSC6900 CATOR TPARA(O Informatio ptional) n3

TESTTIM Test ER Timer

SET BSCNSP BSC6900 ARA(Opti onal)

TRX power-off temperatu re threshold. If the temperatu re of the BTS cabinet is less than the value of this parameter while "Low Temperat ure Startup Allowed" is set to "Yes", the TRX is powered off. In multimode scenario, the value of this parameter in one mode must be Whether the System Informatio n Type 3 message carries TER indication. Duration of the timer for starting the IP path status test on the Gb

GBFD111202

O&M of BTS

Interval Type

-400~0

GBFD111101

System Enumerati NO(No), Informatio on Type YES(Yes) n Sending

GBFD119001

Gb Interface Function

Interval Type

1~255

TEXT

ADD Content GSMSCB of BSC6900 (Mandator Message y)

Content of the cell GBFDbroadcast 113602 message

Simplified Cell Any Type None Broadcast

TFO TFOOptS Option witch Switch

AEC is an important measure to improve the speech quality. If the AEC works for SET a GBFDBSC6900 TCPARA( consecuti 115701 Optional) ve time that is longer than the value of this parameter , the TFO function is closed to provide a

TFO

Enumerati OFF(Off), on Type ON(On)

TFREQ

STR Test BTSVSW Frequenc BSC6900 RTST(Opt y ional)

Frame TFRMST Start ARTTIME Time

SET GCELLO BSC6900 THEXT(O ptional)

In the VSWR test, the TRX transmits signals at a default frequency . You can specify the frequency used for the test. This parameter indicates start frame number of the BTS. It is used to keep synchroni zation between the BTS and MS after the BTS is reinitialized.

GBFD111207

BTS Test Interval Function Type

0~1023

MRFD210301

Configura tion Interval Managem Type ent

0~65535

TG

Target OMU

SWP OMUARE Target BSC6900 A(Mandat OMU ory)

GBFD111203

O&M of BSC

ACTIVE( Active Enumerati OMU), on Type STANDB Y(Standb y OMU)

TGWID

TGW ID

ADD BSC6900 TGWIP(M TGW ID andatory)

None

None

Interval Type

0~255

This parameter indicates the TGW address ADD TGWIPO IP_TRAN of the BSC6900 TGWIP(M None AMIP S IP operation andatory) address and maintena nce console for TGW.

None

IP Address Type

None

This parameter indicates the mask TGW ADD of the TGWIPO IP_TRAN BSC6900 TGWIP(M operation None AMMASK S IP Mask andatory) and maintena nce console for TGW.

None

IP Address Type

None

TGW TGWPEE TRANS RSN Slot No.

Slot number of the ADD BSC6900 BSC6900 TGWIP(M interface None andatory) board interworki ng with TGW.

None

Interval Type

0~5,8~27

TGW TGWPEE Trans RSRN Subrack No.

Subrack number of the ADD BSC6900 BSC6900 TGWIP(M interface None andatory) board interworki ng with TGW.

None

Interval Type

0~11

TH

Th

SET BSSGPP BSC6900 ARA(Opti onal)

SET Volt BTSAIRC THDOFF Threshold BSC6900 ON(Optio for Off nal)

Timer Th. After receiving the MS flow control message, the SGSN uses the values of the updated Bmax and R based on the interval set by this timer. When this parameter is set to a smaller value, the SGSN can use the flow control parameter in a shorter time. In this way, the data can be Voltage threshold for switching off the air conditione r. If the power supply voltage is less than this threshold, the air conditione r needs to be switched off to decrease the impact on the BTS.

GBFD114101

GPRS

Interval Type

5000~600 00

GBFD111202

O&M of BTS

Interval Type

220~280

Voltage threshold for switching on the air conditione r. This parameter assumes that the air conditione r is SET switched Volt BTSAIRC off. If the THDON Threshold BSC6900 ON(Optio power for On nal) supply voltage is greater than this threshold, the air conditione r needs to be switched on to ensure that the BTS runs Combinati on of the THP1 and ARP1 priority in the Interactiv e service. THP1THP1SET THP1AR ARP1 ARP1 GCELLP P1PRIWE BSC6900 priority Priority SCHM(O IGHT weight Weight ptional) determine s the number of the budget blocks and the block schedulin

GBFD111202

O&M of BTS

Interval Type

220~280

GBFD119902

QoS Interval ARP&TH Type P

1~10

THP1THP1AR ARP2 P2PRIWE Priority IGHT Weight

THP1THP1AR ARP3 P3PRIWE Priority IGHT Weight

Combinati on of the THP1 and ARP2 priority in the Interactiv e service. THP1SET ARP2 GCELLP BSC6900 priority SCHM(O weight ptional) determine s the number of the budget blocks and the block schedulin Combinati on of the THP1 and ARP3 priority in the Interactiv e service. THP1SET ARP3 GCELLP BSC6900 priority SCHM(O weight ptional) determine s the number of the budget blocks and the block schedulin

GBFD119902

QoS Interval ARP&TH Type P

1~10

GBFD119902

QoS Interval ARP&TH Type P

1~10

THP2THP2AR ARP1 P1PRIWE Priority IGHT Weight

THP2THP2AR ARP2 P2PRIWE Priority IGHT Weight

Combinati on of the THP2 and ARP1 priority in the Interactiv e service. THP2SET ARP1 GCELLP BSC6900 priority SCHM(O weight ptional) determine s the number of the budget blocks and the block schedulin Combinati on of the THP2 and ARP2 priority in the Interactiv e service. THP2SET ARP2 GCELLP BSC6900 priority SCHM(O weight ptional) determine s the number of the budget blocks and the block schedulin

GBFD119902

QoS Interval ARP&TH Type P

1~10

GBFD119902

QoS Interval ARP&TH Type P

1~10

THP2THP2AR ARP3 P3PRIWE Priority IGHT Weight

THP3THP3AR ARP1 P1PRIWE Priority IGHT Weight

Combinati on of the THP2 and ARP3 priority in the Interactiv e service. THP2SET ARP3 GCELLP BSC6900 priority SCHM(O weight ptional) determine s the number of the budget blocks and the block schedulin Combinati on of the THP3 and ARP1 priority in the Interactiv e service. THP3SET ARP1 GCELLP BSC6900 priority SCHM(O weight ptional) determine s the number of the budget blocks and the block schedulin

GBFD119902

QoS Interval ARP&TH Type P

1~10

GBFD119902

QoS Interval ARP&TH Type P

1~10

THP3THP3AR ARP2 P2PRIWE Priority IGHT Weight

SET GCELLP BSC6900 SCHM(O ptional)

THP3THP3AR ARP3 P3PRIWE Priority IGHT Weight

SET GCELLP BSC6900 SCHM(O ptional)

THTYPE

ADD Threshold TRMLOA BSC6900 type DTH(Man datory)

Combinati on of the THP3 and ARP2 priority in the Interactiv e service. THP3ARP2 priority weight determine s the number of the budget blocks and the block schedulin Combinati on of the THP3 and ARP3 priority in the Interactiv e service. THP3ARP3 priority weight determine s the number of the budget blocks and the block schedulin Load balance threshold type. It indicates the threshold calculatio n mode.

GBFD119902

QoS Interval ARP&TH Type P

1~10

GBFD119902

QoS Interval ARP&TH Type P

1~10

GBFD118605

IP QOS

PERCEN TAGE(Pe Enumerati rcentage), on Type BANDWI DTH(Ban d Width)

TI_WAIT_ SGSN_P RIVATE_ MESSAG E

Receive SGSN Config. Msg. Timer

SET BSC6900 BSCTMR( Optional)

TIGHTBC CHASSM AINBCCH LEV

Level Thresh for SET Assign GCELLC BSC6900 BCCH HMGAD( Under Optional) TBCCH

This parameter specifies the timer set to wait for a private message from the SGSN. During channel assignme nt, the assignme nt of channels on the BCCH TRXs depends on the uplink receive level, quality, and nonBCCH load. The TCHs are preferenti ally assigned on the BCCH TRXs if the following conditions are met: 1. The uplink receive level after

GBFD119701

SGSN Pool

Interval Type

1~15

GBFD118001

BCCH Dense Frequenc Interval y Type Multiplexi ng

0~63

During channel assignme nt, the assignme nt of channels on the BCCH TRXs depends on the uplink receive Quality level, TIGHTBC Thresh for SET quality, CHASSM Assign GCELLC and non- GBFDBSC6900 AINBCCH BCCH HMGAD( BCCH 118001 QUAL Under Optional) load. The TBCCH TCHs are preferenti ally assigned on the BCCH TRXs if the following conditions are met: 1. The uplink receive level after

BCCH Dense Frequenc Interval y Type Multiplexi ng

0~7

The P/N criterion must be met for triggering a TIGHT BCCH handover. That is, the TIGHT BCCH TIGHT SET handover TIGHTBC BCCH GCELLH can be GBFDCHHOLA BSC6900 HO Valid OBASIC( triggered 118001 STTIME Time Optional) only if P seconds among N seconds meet the triggering conditions . This parameter correspon ds to P in the P/N criterion.

BCCH Dense Frequenc Interval y Type Multiplexi ng

1~32

During channel assignme nt, the assignme nt of channels on the BCCH TRXs depends on the uplink receive level, Load TIGHTBC SET quality, Threshold CHHOLO GCELLH and non- GBFDfor TIGHT BSC6900 ADTHRE OAD(Opti BCCH 118001 BCCH S onal) load. The HO TCHs are preferenti ally assigned on the BCCH TRXs if the following conditions are met: 1. The uplink receive level after

BCCH Dense Frequenc Interval y Type Multiplexi ng

0~100

TIGHT TIGHTBC BCCH CHHOST HO ATTIME Watch Time

SET GCELLH BSC6900 OBASIC( Optional)

TIGHTBC CHRXQU ALTHRE S

RX_QUA L SET Threshold GCELLH BSC6900 for TIGHT OAD(Opti BCCH onal) HO

TIGHTBC TIGHT CHSWIT BCCH CH Switch

SET GCELLC BSC6900 HMGBASI C(Optiona l)

The P/N criterion must be met for triggering a TIGHTBC CH handover. That is, the TIGHTBC CH handover can be triggered only if P seconds among N seconds meet the triggering conditions . This parameter correspon ds to N in When an intra-cell TIGHT BCCH handover needs to be performe d (handover from the nonBCCH to BCCH), the downlink receive quality must be smaller than the value of this Whether to enable the BCCH aggressiv e frequency reuse algorithm

GBFD118001

BCCH Dense Frequenc Interval y Type Multiplexi ng

1~32

GBFD118001

BCCH Dense Frequenc Interval y Type Multiplexi ng

0~7

GBFD118001

BCCH Dense Frequenc Enumerati OFF(Off), y on Type ON(On) Multiplexi ng

If the SDCCH load on the TRXs of the compatibl e BCCH in loose frequency reuse pattern is greater than the "IBCA Loose Trx IBCA TIGHTSD SET SDCCH Tight Trx CCHRXL GCELLC Load GBFDSDCCH BSC6900 EVTHRE HMGAD( Threshold 117002 Rxlev D Optional) ", and Threshold when the uplink receive level from the MS to the BTS is greater than the threshold, the SDCCHs on the TRXs of the compatibl

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~63

IMSI TIIMSIPA Paging GING Timer

TIME

Time Limit

IMSI paging timer. After enabling the MSC pool function, the BSC6900 receives from the MSC the paging message ADD attached GCNOPE with the BSC6900 RATOR( IMSI. Optional) Then, the BSC6900 records the relation between the IMSI and the MSC SP and starts the timer with predefine d length. If the BSC6900 Whether to limit the ADD operation BSC6900 OP(Optio time of nal) the operator

GBFD117401

MSC Pool

Interval Type

3~15

GBFD111203 MRFD210305

O&M of NOLIMIT( BSC Enumerati No Limit), Security on Type LIMIT(Lim Managem it) ent

TIME

Time

SET BSC6900 TIME(Opti Time onal)

GBFD111203

O&M of BSC

Compoun HOUR, d Type MIN, SEC

TIME

Duration

SET GCELLF BSC6900 REQSCA N(Optiona l)

Duration of GBFDfrequency 112401 scanning

Cell Interval Frequenc Type y Scan

0,5~1440

Within the preset time, no AMR FRto-HR handover is allowed Penalty SET if the TIMEAMR Time after GCELLH previous FHPUNIS AMR BSC6900 OFITPEN FR-to-HR H TCHF-H (Optional) handover HO Fail fails due to channel unavailabi lity or channel mismatch.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

After a handover due to bad quality is successfu l, the penalty on the original serving cell is performe d within the SET "Penalty Penalty TIMEBQP GCELLH Time after Time after BSC6900 UNISH OFITPEN BQ HO": BQ HO (Optional) the receive level of the original serving cell is decrease d by "Penalty Level after BQ HO", to prevent ping-pong handover

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

After an OL subcell to UL subcell handover of an MS fails, the Penalty SET MS does TIMEOTO Time after GCELLH not GBFDUFAILPU BSC6900 OtoU HO OIUO(Opt perform 113201 N Fail ional) OL subellUL subcell handover s within the value of the parameter .

Concentri Interval c Cell Type

0~255

Indicates the Reply PING timeout TIMEOUT TimeBSC6900 IP(Option time of Out[ms] al) the PING packet Timeout time for Reply TRC waiting for TIMEOUT TimeBSC6900 IPADDR( the Out[ms] Optional) TRACER T packet response PING MAC(Opti onal) Timeout Timeout Time Out BSC6900 PING time BTSCFM( Optional) Indicates TRC the MAC(Opti timeout onal) TIMEOUT Time Out BSC6900 time of TRC the CFM BTSCFM( link Optional) tracing Longest waiting time for multiplexi ng When the multiplexe d packet is no longer added with new data and the timer expires, ADD the Maximum BTSABIS multiplexe TIMEOUT Delay BSC6900 MUXFLO d packet Time W(Option is al) transmitte d directly. This parameter is determine d by the number of multiplexe d packets. When the number of multiplexe d packets increases,

GBFD118630

Ethernet OAM

Interval Type

200~1000 0

GBFD118630

Ethernet OAM

Interval Type

1~65535

GBFD118630

Ethernet OAM

Interval Type

1~3

GBFD118630

Ethernet OAM

Interval Type

1~10

GBFD118604

Abis MUX

Interval Type

1~20

ADD GEXT2G Quick CELL(Opt TIMEPUN Handover ional) BSC6900 ISH Punish SET Time GCELLH OFAST(O ptional)

TIMES

Number of ping packets

PING BSC6900 IP(Option al)

After the fast handover is successfu l, the penalty on the original serving cell is performe d within the "Quick handover punish time": the receive level of the original serving cell is decrease d by "Quick handover punish value", to prevent ping-pong handover s. Indicates the times of sending PING packets

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

None

None

Interval Type

1~1024

This parameter determine s whether the dynamic voltage adjustme nt function is enabled on the basis of the number of Voltage SET timeslots. TIMESLO Adjust GCELLB GBFDIf this TVOLADJ Based BSC6900 ASICPAR parameter 111606 ALLOW Timeslots A(Optiona is set to Allowed l) YES, the power consumpti on of base stations is reduced. This parameter maps the versions of base stations. If the parameter

Power NO(No), Optimizati YES(Yes) on Based Enumerati , on on Type NULL(Nul Channel l) Type

After the time advancing handover is successfu l, the penalty on the original serving cell is performe d within the SET "Penalty Penalty TIMETAP GCELLH Time after Time after BSC6900 UNISH OFITPEN TA HO": TA HO (Optional) the receive level of the original serving cell is decrease d by "Penalty Level after TA HO", to prevent ping-pong handover After an

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

UL subcell to OL subcell handover of an MS fails, the MS does Penalty SET TIMEUTO not Time after GCELLH GBFDOFAILPU BSC6900 perform UtoO HO OIUO(Opt 113201 N UL Fail ional) subcell to OL subcell handover s within the value of the parameter .

Concentri Interval c Cell Type

10~255

This parameter indicates the queue timer for assignme nt. When the BSC6900 receives an assignme nt request and no channel is SET available TIQUEUI GCELLT for NGTIME T11 BSC6900 MR(Optio assignme R nal) nt, the BSC6900 starts the queuing procedure and the timer. If the channel request is successfu l before the timer expires, the timer stops. If If the BSC6900 receives the configurat ion data about all Receive the MSC ADD connecte TIWAITM Configura GCNOPE d MSCs BSC6900 SCMSG tion RATOR( before the Message Optional) timer Timer expires, the BSC6900 concludes that the configurat ion data is valid.

GBFD111005

Enhanced Channel Interval Assignme Type nt Algorithm

1~30

GBFD117401

MSC Pool

Interval Type

1~15

TL

TLLI

TLT

When the operation time of the OMU exceeds the value SET specified Time LOGLIMI by this BSC6900 Limit T(Optiona parameter l) , some records are deleted from the operation log. SET MSTOCE LL(Manda tory) Temporar TST y logical SNDRSI( link ID in TLLI BSC6900 Mandator the y) decimal TST format UPDMSR AC(Mand atory) Lowest expected value of the air outlet temperatu re. In multimode scenario, SET the value BTSDHE of this Tout Limit BSC6900 UBP(Opti parameter onal) in one mode must be the same as the value of the correspon ding parameter in another

GBFD111203 MRFD210305

O&M of BSC Interval Security Type Managem ent

7~365

GBFD114101

GPRS

Interval Type

0~429496 7295

GBFD111202

O&M of BTS

Interval Type

-99~70

TLTHD

Temperat ure alarm lower threshold. If the temperatu re of the battery is lower than the value of this parameter , an alarm indicating Temperat SET the ure Alarm BTSAPM abnormal GBFDBSC6900 Lower UBP(Opti temperatu 111202 Threshold onal) re is reported. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon

O&M of BTS

Interval Type

-19~5

TLTHD

Temperat SET ure Alarm BTSDHE BSC6900 Lower UBP(Opti Threshold onal)

TM

Execute Time

ADD SUBTSK( BSC6900 Mandator y)

When the internal temperatu re of the BTS reaches the Temperat ure Alarm Lower Threshold , it reports a low temperatu re alarm. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter in another mode. When the time mode is set to "ONTIME" , you should set this

GBFD111202

O&M of BTS

Interval Type

-99~99

GBFD111203

O&M of BSC

Compoun hour, min d Type

TM1

Execute Time 1

ADD SUBTSK( BSC6900 Mandator y)

TM2

Execute Time 2

ADD BSC6900 SUBTSK( Optional)

If the time mode is set to "DAILY_T ", "WEEKLY _T", or "MONTHL Y_T", you should set this parameter . This parameter specifies the first execution time in the day in which the scheduled task is executed. If the time mode is set to "DAILY_T ", "WEEKLY _T", or "MONTHL Y_T", you should set this parameter . This parameter specifies the second execution time in the day in which the scheduled task is

GBFD111203

O&M of BSC

Compoun hour, min d Type

GBFD111203

O&M of BSC

Compoun hour, min d Type

TM3

Execute Time 3

ADD BSC6900 SUBTSK( Optional)

TM4

Execute Time 4

ADD BSC6900 SUBTSK( Optional)

If the time mode is set to "DAILY_T ", "WEEKLY _T", or "MONTHL Y_T", you should set this parameter . This parameter specifies the third execution time in the day in which the scheduled task is executed. If the time mode is set to "DAILY_T ", "WEEKLY _T", or "MONTHL Y_T", you should set this parameter . This parameter specifies the fourth execution time in the day in which the scheduled task is executed.

GBFD111203

O&M of BSC

Compoun hour, min d Type

GBFD111203

O&M of BSC

Compoun hour, min d Type

TM5

TMI

If the time mode is set to "DAILY_T ", "WEEKLY _T", or "MONTHL Y_T", you should set ADD this Execute GBFDBSC6900 SUBTSK( parameter Time 5 111203 Optional) . This parameter specifies the fifth execution time in the day in which the scheduled task is executed. ADD TRMMAP TRMMAP TRMMAP GBFDBSC6900 ID (Mandator index 118605 y) Index of the traffic mapping ADD used by TRMMAP ADJMAP( BSC6900 the None index Mandator current y) adjacent node's gold user. STR Loopback FRPORT BSC6900 time None LOOP(Ma length ndatory)

O&M of BSC

Compoun hour, min d Type

IP QOS

Interval Type

14~163

TMIGLD

None

Interval Type

0~163

TMLEN

Time Length

None

Interval Type

1~120

TMODE

Test Mode

This parameter is valid to DRFU only. When this parameter is set to NON_FD R(NON_F DR), only the VSWR of the point where the STR VSWR on BTSVSW the GBFDBSC6900 RTST(Opt antenna 111207 ional) path is maximum (hereinaft er referred to as fault point) is reported. When this parameter is set to FDR(FDR ), both the VSWR of the fault point and

NON_FD R(NON_F BTS Test Enumerati DR), Function on Type FDR(FDR )

Duration time for determini ng that a call is hung up because of poor quality. If the uplink quality or downlink quality in the measure Timer for SET ment TMRBAD Bad GCELLS reports GBFDQUALDIS Quality BSC6900 OFT(Opti during the 110501 CSTAT DISC onal) period of Statistic Timer for "Bad Quality DISC Statistic" is higher than the value of "Bad Quality Disconne ction Threshold " before the call is

Call Control

Interval Type

2~4

Maximum rate of the accumulat ed alarm blink duration to the alarm blink measure ment period. Assume this threshold Upper SET is not 0. time TMRISTH ALMBLKP When the MRFDthreshold BSC6900 RD ARA(Opti rate of 210304 of raised onal) accumulat fault ed alarm blink duration exceeds the threshold, an alarm is reported. For querying the alarm blink measure ment CHK INNSPCH (Mandator y) STR CALLRES TMSI of GBFDTMSI TMSI BSC6900 LOP(Man the MS 111203 datory) ADD GCSCHR USER(Ma ndatory)

Faulty Interval Managem Type ent

0~100

O&M of BSC

Interval Type

0~429496 7294

TMSTLT HRD

Lower SET time ALMBLKP threshold BSC6900 ARA(Opti of raised onal) fault

SET Signalling TMT1TM MTP3TM link test BSC6900 R R(Optiona ACK timer l)

Minimum rate of the accumulat ed alarm blink duration to the alarm blink measure ment period. Assume this threshold is not 0. When the rate of accumulat ed alarm blink duration is lower than the threshold, an alarm is reported. For querying the alarm blink measure ment This timer is a protection timer waiting for a signalling link test acknowle dgement message (SLTA) from the peer end after a signalling link test message (SLTM) is sent to the peer

MRFD210304

Faulty Interval Managem Type ent

0~100

GBFD111804

A Interface Protocol Process

Interval Type

8000~120 00

This timer is used to send the Signalling SET signalling TMT2TM link MTP3TM link test GBFDBSC6900 R repeat R(Optiona message 111804 test timer l) s (SLTM) to the peer end regularly.

A Interface Protocol Process

Interval Type

30000~90 000

TNAME

Data Table

Name of the data CMP table MRFDBSC6900 TBLDATA distribute 210301 (Optional) d on the board.

ABLMSG TYPEPA RAS, ACALGO PARAS, ADMCTL PARAS, AICH, AMRCSQ ICOUNTP ARAS, APN, BCH, CBSADD R, Configura CBSCELL tion Enumerati SAC, Managem on Type CELLAC ent CESSCL ASSBAR REDLIST, CELLAC CESSRE STRICT, CELLAC CESSRE STRICTB ARREDP ARA, CELLACT TIMEOFF SET, CELLAM RCPARA

ADD ATERSL( Transmis Optional) TNMODE sion BSC6900 ADD Mode ATERCO NSL(Opti onal)

Transmis ADD TNMODE sion BSC6900 PBE1T1( Mode Optional)

The Ater signaling link operates in the terrestrial transmissi on or satellite transmissi on mode. In the areas such as desert and lake where the terrestrial transmissi on is difficult, the satellite transmissi on can be used. E1 transmissi on type of the Pb interface. The terrestrial transmissi on or satellite transmissi on can be selected. In the areas such as desert and lake where the terrestrial transmissi on is difficult, the satellite transmissi on can be used.

GBFD113903

TRRS(Ter restrial Satellite Transmis Transmis Enumerati sion), sion over on Type SATEL(S Ater atellite Interface Transmis sion)

GBFD111203

O&M of BSC

TRRS(Ter restrial Transmis Enumerati sion), on Type SATEL(S atellite Transmis sion)

TO

Offset to DST, SET AdjustMet namely, BSC6900 TZ(Mand hod the atory) adjustme nt to time.

GBFD116101 MRFD210301

TO

Cell Reselect Temporar y Offset (TO) indicates the temporary correction of C2. This parameter is valid Cell SET only Reselect GCELLID GBFDBSC6900 within the Temporar LEAD(Opt 110402 value y Offset ional) specified by "Cell Reselect Penalty Time". For details, see GSM Rec. 05.08 and 04.08. This parameter Number ADD of the BTSTOP cabinet MRFDBSC6900 CONFIG( where the 211501 Optional) board is located ADD BTSTOP BSC6900 CONFIG( Mandator y) Number of the slot MRFDwhere the 211501 board is located

Support of Daylight Saving Interval Time Type Configura tion Managem ent

-120~1,1~120

Basic Cell Interval ReType selection

0~7

TOP TOPBOA Board RDCN Cabinet No.

IP-Based 2G/3G CoTransmis Interval sion on Type Base Station Side IP-Based 2G/3G CoTransmis Interval sion on Type Base Station Side IP-Based 2G/3G CoTransmis Interval sion on Type Base Station Side

0~62

TOPBOA TOP RDSLOT Board NO Slot No.

0~23

TOP TOPBOA Board RDSRN Subrack No.

Number ADD of the BTSTOP subrack MRFDBSC6900 CONFIG( where the 211501 Optional) board is located

0~254

TP

TPN

Type of the host log to be collected. If this parameter is set to NORMAL, the text log in the \common\ fam\famlo g directory of the COL OMU FAMLOG( installatio GBFDLog Type BSC6900 Mandator n path is 111203 y) collected and saved in the \common\ fam\famlo g directory of the OMU installatio n path. If this parameter is set to FORMAT, Number ADD of the BTSRXU optical CHAIN(M port Tail Port andatory) GBFDBSC6900 where the No. CBN 111202 main BTSRXU board of CHAIN(M the RXU andatory) ring is

O&M of BSC

NORMAL (TXT FORMAT) Enumerati , on Type FORMAT( BIN FORMAT)

O&M of BTS

Interval Type

0~5

Length of the timer that is started to wait for a channel requested by an incoming BSC handover request message. When the MSC Into-BSC SET allows the HO REQ GCELLT queuing TQHO BSC6900 Queue MR(Optio of Timer nal) incoming BSC handover requests, the BSC6900 starts the queuing procedure and the timer if no channel is available for assignme nt. If the CPU usage threshold for debuggin g tracing flow control. When the Debug SET average TRACEC tracking FCCPUT CPU BSC6900 THD control HD(Optio usage of threshold nal) sliding windows reaches or exceeds the threshold, debuggin g tracing flow

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~30

GBFD111705

GSM Flow Control

Interval Type

30~100

Debug SET TRACEC tracking FCMSGQ BSC6900 THD control THD(Opti threshold onal)

Debug SET TRACER tracking FCCPUT BSC6900 THD restore HD(Optio threshold nal)

Packet queue usage threshold for debuggin g tracing flow control. When the average packet queue usage of sliding windows reaches or exceeds the threshold, debuggin g tracing flow CPU usage threshold for recovery from debuggin g tracing flow control. When the average CPU usage of smooth windows is lower than the threshold, debuggin g tracing flow control is

GBFD111705

GSM Flow Control

Interval Type

30~100

GBFD111705

GSM Flow Control

Interval Type

30~100

Packet queue usage threshold for recovery from debuggin g tracing flow control. Debug SET When the TRACER tracking FCMSGQ GBFDBSC6900 average THD restore THD(Opti 111705 packet threshold onal) queue usage of smooth windows is lower than the threshold, debuggin g tracing flow control is Debug TRACES Flow W control switch Whether to control SET the GBFDBSC6900 FCSW(O debuggin 111705 ptional) g tracing flow

GSM Flow Control

Interval Type

30~100

GSM Flow Control

Enumerati ON, OFF on Type

SET DL TrafficCla BSCPSS Priority ssDlCoeff BSC6900 OFTPAR Decision icient A(Optiona Threshold l)

SET UL TrafficCla BSCPSS Priority ssUlCoeff BSC6900 OFTPAR Decision icient A(Optiona Threshold l)

Threshold for determini ng whether the uplink service is preferred. Within the "Flux Measure ment Period", if the ratio of the downlink LLC PDU flux and uplink LLC PDU flux is higher than the threshold, the service type of the MS is Threshold for determini ng whether the uplink service is preferred. Within the "Flux Measure ment Period", if the ratio of the uplink LLC PDU flux and downlink LLC PDU flux is higher than the threshold, the service type of the MS is

GBFD119501

Adaptive Adjustme nt of Interval Uplink Type and Downlink Channels

1~255

GBFD119501

Adaptive Adjustme nt of Interval Uplink Type and Downlink Channels

1~255

TRAMOD Traffic E mode

Traffic mode of the M3UA link set. At present, only the active/sta ndby and load sharing mode is available. If the M3UA links in ADD GBFDthe link BSC6900 M3LKS(O set work 118602 ptional) in overriding mode, only one link in the link set works in the active mode, and all other links work in the standby mode. In this case,

M3UA_O VERRIDE _MOD(Ac tive/Stand by Mode), Enumerati A over IP M3UA_L on Type OADSHA RE_MOD (Load Sharing Mode)

This parameter specifies the data transmissi on mode between the BTS and the BSC6900. The license control modes are SET different Transmis TransMod BTSTRA in GBFDsion BSC6900 e NS(Mand different 113901 Mode atory) transmissi on modes. Terrestrial Transmis sion: The data between the BTS and the BSC6900 is transmitte d through the E1 or fiber. This Slot ADD Load ABISLOA TRANSS Transmitti BSC6900 DSHARE( N ng Slot Mandator No. y) number of the transpare GBFDntly 111203 transmitti ng interface board Transport

TER_TRA NS(Terre strial Transmis sion), SAT_TRA Satellite NS(Satelli Transmis Enumerati te sion over on Type Transmis Abis sion), Interface TER_AN D_SAT_T RANS(Te rrestrial and Satellite)

O&M of BSC

Interval Type

0~27

type of the ADD Transport adjacent GBFDTRANST BSC6900 IPPATH( Type 118605 node to Optional) which the path belongs.

IP QOS

Enumerati IP(IP) on Type

TRANST

ADD Transport Transport GBFDBSC6900 TRMMAP Type type 118605 (Optional)

IP QOS

IP(IP), Enumerati HDLC(HD on Type LC)

ADD Transport TRMLOA Transport GBFDTRANST BSC6900 Type DTH(Man type 118605 datory)

IP QOS

IP(IP), HDLC(HD Enumerati LC), on Type TDM(TD M)

TRANST Carrier YPE Type

SET BSCABIS BSC6900 PRIMAP( Mandator y)

Transmis sion type GBFDof the 111202 BTS

O&M of BTS

Enumerati IP, HDLC, on Type TDM

SET BTS TRANST BTSBWP Transmis GBFDTransmis BSC6900 YPE ARA(Man sion Type 118601 sion Type datory) Whether to configure the optical transmissi on mode for E1 port 0 of the E1 Port 0 BTS3006 Set SET C/BTS30 TRANST Optical BTSDOM GBFDBSC6900 02E. If the YPE0 Transmis UBP(Opti 111202 optical sion onal) transmissi Mode on mode is configure d, the BSC6900 can connect to the BTS

Abis over Enumerati HDLC, IP IP on Type

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

E1 Port 1 Set SET TRANST Optical BTSDOM BSC6900 YPE1 Transmis UBP(Opti sion onal) Mode

E1 Port 2 Set SET TRANST Optical BTSDOM BSC6900 YPE2 Transmis UBP(Opti sion onal) Mode

Whether to configure the optical transmissi on mode for E1 port 1 of the BTS3006 C/BTS30 02E. If the optical transmissi on mode is configure d, the BSC6900 can connect to the BTS Whether to configure the optical transmissi on mode for E1 port 2 of the BTS3006 C/BTS30 02E . If the optical transmissi on mode is configure d, the BSC6900 can connect to the BTS

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

GBFD111202

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

Whether to configure the optical transmissi on mode for E1 port 3 of the E1 Port 3 BTS3006 Set SET C/BTS30 TRANST Optical BTSDOM GBFDBSC6900 02E. If the YPE3 Transmis UBP(Opti 111202 optical sion onal) transmissi Mode on mode is configure d, the BSC6900 can connect to the BTS

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

TRCRNG Trace LMT Mode

SET BTSCLKP BSC6900 ARA(Man datory)

Whether to enable the limit of GBFDthe 111202 tracing range

O&M of BTS

ENABLE( Enable Trace Range Enumerati Limit), on Type DISABLE( Disable Trace Range Limit) 5sec(5se c), 10sec(10 sec), 15sec(15 sec), 20sec(20 sec), Enumerati 30sec(30 on Type sec), 60sec(60 sec), 120sec(1 20sec), 300sec(3 00sec), nouse(no use)

TRESEL

Cell SET Forbidden Reselecti GCELLR time of GBFDon BSC6900 ESELECT cell 114101 Forbidden PARA(Op reselectio Time tional) n

GPRS

The load handover is triggered SET when the TRIGTHR Load HO GCELLH traffic BSC6900 ES Threshold OAD(Opti load in a onal) cell is greater than the value of this

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~100

TRKLNK Trunk PN Link No.

ADD ETHTRKL BSC6900 NK(Mand atory)

Port number of the MRFDaggregati 210103 on member Slot number of the MRFDaggregati 210103 on member

Link Interval aggregati Type on

0~11

Trunk TRKLNK Link Slot SN No.

ADD ETHTRKL BSC6900 NK(Mand atory)

Link Interval aggregati Type on

0~5,8~27

TRKN

Specified TRMMAP TRMI index of the user panel TRM load threshold index. TRMLOA TRM load ADD The TRM DTHINDE threshold BSC6900 IPPATH( load X index Optional) threshold must be configure

ADD ETHTRK( Mandator y) ADD ETHTRKL Trunk No. BSC6900 NK(Mand atory) ADD ETHTRKI P(Mandat ory) SET User BSCABIS TRMMAP BSC6900 PRIMAP( index Mandator y)

aggregati MRFDon group 210103 number

Link Interval aggregati Type on

0~11

GBFD111202

O&M of BTS

Interval Type

0~163

GBFD118605

IP QOS

Interval Type

0~199

TRMLOA TRM load ADD TRM load DTHINDE threshold BSC6900 RSCGRP threshold None X index (Optional) index

None

Interval Type

0~199

ADD TRMLOA TRM load TRMLOA DTHINDE threshold BSC6900 DTH(Man X index datory)

TRMLOA TRM load ADD DTHINDE threshold BSC6900 PPPLNK( X index Optional)

TRM load threshold index. It is the unique ID of the load threshold. TRM load threshold index

None

None

Interval Type

10~199

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1 Abis IP over Interval E1/T1 Type A IP over E1/T1

0~199

GBFDTRMLOA TRM load ADD TRM load 118611 DTHINDE threshold BSC6900 MPGRP( threshold GBFDX index Optional) index 118622 ADD TRMLOA TRM load TRM load IPLOGIC GBFDDTHINDE threshold BSC6900 threshold PORT(Op 118605 X index index tional)

0~199

IP QOS

Interval Type

0~199

SET TRMLOA TRM load BSCABIS TRM load DTHINDE threshold BSC6900 PRIMAP( threshold None X index Mandator index y)

None

Interval Type

0~199

Transmis Transport SET sion TRMMAP Resource BSCABIS GBFDBSC6900 resources SW Mapping PRIMAP( 111202 mapping switch Optional) switch Trunk ADD group The Trunk IPLOGIC TRUNKN BSC6900 number of None group No. PORT(Op the logical tional) port

O&M of BTS

Enumerati OFF(OFF on Type ), ON(ON)

None

Interval Type

0~11

STR TRUNK Trunk TRUNKN BSC6900 IPCHK(O group group No. ptional) number ADD TRUNK ETHMEP( TRUNKN Trunk No. BSC6900 group Mandator number y) Whether to enable the TRX aiding function. Four aiding modes are available. BCCH aiding: The main BCCH is aided to SET TRX another GCELLC TRXAIDS Aiding normal BSC6900 CACCES WITCH Function TRX in S(Optiona Control this cell. l) BCCH aiding switchbac k: BCCH aiding switchbac k functions after the originally configure d BCCH TRX is recovered . STR BTSTST( BSC6900 Duration Mandator y)

GBFD118609

IP Fault Detection Interval Based on Type BFD Ethernet OAM Interval Type

0~11

GBFD118630

0~11

GBFD113801

TRXAid_ NotAllow( TRX Aiding Not Allowed), AllowReF orbid(Allo wed & Recover Forbidden TRX Enumerati ), Cooperati on Type AllowReI on mmed(All owed & Recover Immediat ely), AllowReC heckRes( Allowed & Recover When Chk Res)

TRXDUR Duration ATS Second

GBFD111207

BTS Test Interval Function Type

5~10

SET TRXHOPI Channel GTRXCH BSC6900 NDEX Hop Index ANHOP( Optional)

Frequenc y hopping index of GBFDthe 113701 channel in the TRX

Frequenc y Hopping (RF Interval hopping, Type baseband hopping)

0~63,255

TRXID

TRX ID

SET FHO(Man datory) SET GTRXCH ANHOP( Mandator y) SET GTRXHO P(Mandat ory) SET GTRXBA SE(Mand atory) SET BSC6900 GTRXCH AN(Mand atory) SET GTRXFC( Mandator y) SET GTRXIUO (Mandator y) SET GTRXAD MSTAT(M andatory) SET GTRXCH

Index of a TRX, uniquely MRFDidentifying 210301 a TRX in a BSC6900.

Configura tion Interval Managem Type ent

0~3071

TRXID

TRX ID

The ID of TRX added in the main location group, the TRX ID must be ADD globally BTSBIND unique. GBFDBSC6900 LOCGRP( The same 510104 Mandator TRX y) cannot be bound by the TRX boards in a same location group for multiple times.

Multi-site Interval Cell Type

0~3071

TRXID1

ADD GCELLH No.1 TRX Index of BSC6900 OPANTG ID TRX 1 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID10

No.10 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 10 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID11

No.11 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 11 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID12

No.12 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 12 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID13

No.13 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 13 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID14

No.14 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 14 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID15

No.15 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 15 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID16

No.16 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 16 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID17

No.17 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 17 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID18

No.18 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 18 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID19

No.19 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 19 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID2

ADD GCELLH No.2 TRX Index of BSC6900 OPANTG ID TRX 2 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID20

No.20 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 20 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID21

No.21 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 21 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID22

No.22 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 22 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID23

No.23 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 23 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID24

No.24 TRX ID

ADD GCELLH Index of BSC6900 OPANTG TRX 24 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID3

ADD GCELLH No.3 TRX Index of BSC6900 OPANTG ID TRX 3 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID4

ADD GCELLH No.4 TRX Index of BSC6900 OPANTG ID TRX 4 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID5

ADD GCELLH No.5 TRX Index of BSC6900 OPANTG ID TRX 5 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID6

ADD GCELLH No.6 TRX Index of BSC6900 OPANTG ID TRX 6 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID7

ADD GCELLH No.7 TRX Index of BSC6900 OPANTG ID TRX 7 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID8

ADD GCELLH No.8 TRX Index of BSC6900 OPANTG ID TRX 8 RP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXID9

ADD GCELLH No.9 TRX Index of BSC6900 OPANTG ID TRX 9 RP(Optio nal) SET GCELLH OPQUIC KSETUP( Optional) BSC6900 SET GCELLH OPANTQ UICKSET UP(Optio nal)

GBFD113703

Antenna Interval Frequenc Type y Hopping

0~3071

TRXIDLS TRXID T LST

List of IDs of carriers GBFDfor 113701 frequency hopping.

Frequenc y Hopping (RF String hopping, Type baseband hopping)

None

List of TRX indexes. You can specify one TRX STR index or TRXIDLS TRX TRXPER GBFDBSC6900 more TRX T Index List FTST(Ma 111207 indexes, ndatory) for example, 1 or 0&1&2&& 5 in the same

BTS Test Interval Function Type

0~3071

TRXMAIO

Channel MAIO

Mobile allocation SET index GTRXCH offset GBFDBSC6900 ANHOP( (MAIO) of 113701 Optional) the channel in the TRX

Frequenc y Hopping (RF Interval hopping, Type baseband hopping)

0~63

TRXNO

TRX No.

TrxNum

TRX Number

Number of a TRX in a BTS. ADD MRFDThe BSC6900 GTRX(Op number of 210301 tional) a TRX is unique in a BTS. ADD BTSBRD Allowed CAP(Man number of datory) GBFDBSC6900 TRXs ADD 111202 bound to BTSRXU a board. BRD(Opti onal)

Configura tion Interval Managem Type ent

0~71

O&M of BTS

Interval Type

0~8

TRXPN

Number of the channel bound to the TRX on the TRX board. TRX Pass No. of the DTRU/DR RU/BTS3 900B of the BTS in ADD separate TRX TRXBIND GBFDmode Board BSC6900 2PHYBR must be 0 111202 Pass No. D(Mandat or 1; TRX ory) Pass No. of the QTRU/M RFU/GRF U/BTS39 00E of the BTS in separate mode must be 0 to 5; TRX Pass No. of the GRRU/M RRU of TRX board pass number in SubADD the subLocation BTSBIND location Group GBFDBSC6900 LOCGRP( group to TRX 510104 Mandator which the Board y) TRX of Pass No. the main location group is bound

O&M of BTS

Interval Type

0~7

TRXPN

Multi-site Interval Cell Type

0~7

This parameter specifies whether the TRX priority is considere d during channel assignme nt. When the parameter is set to YES, the Allocation SET smaller TRXPRIA TRX GCELLC the GBFDBSC6900 LLOW Priority HMGAD( parameter 111005 Allowed Optional) "TRX Priority" in the command "SET GTRXDE V" is, the higher priority the TRX is. Under other conditions , channels are preferenti

Enhanced Channel Enumerati NO(No), Assignme on Type YES(Yes) nt Algorithm

TRXTP

TRX Board Type

ADD TRXBIND BSC6900 2PHYBR D(Mandat ory)

Type of the TRX board bound to the TRX

GBFD111202

O&M of BTS

TRX(TRX ), TRU(TRU /DTRU), QTRU(QT RU), DRRU(D RRU), DRFU(DR FU), MRRU(M Enumerati RRU), on Type MRFU(M RFU), GRFU(G RFU), GRRU(G RRU), BTS3900 B(BTS39 00B), BTS3900 E(BTS39 00E)

TS

BLK ATERE1T Time Slot BSC6900 1(Mandat ory)

It indicates the Ater GBFDinterface 111801 timeslot number

Ater Interface Interval 4:1 Type Multiplexi ng

8~255

TS

It indicates the A interface BLK timeslot GBFDTime Slot BSC6900 AE1T1(M number. 111803 andatory) The parameter supports multiple values.

A Interface Interval Circuit Type Managem ent

1~31

TS

time slot No.

LOP E1T1(Ma ndatory) Timeslot BSC6900 STR number E1T1TST (Optional)

None

None

TS1(Time _slot_1), TS2(Time _slot_2), TS3(Time _slot_3), TS4(Time _slot_4), TS5(Time _slot_5), TS6(Time _slot_6), TS7(Time _slot_7), TS8(Time _slot_8), Enumerati TS9(Time on Type _slot_9), TS10(Tim e_slot_10 ), TS11(Tim e_slot_11 ), TS12(Tim e_slot_12 ), TS13(Tim e_slot_13 ), TS14(Tim e_slot_14 ), TS15(Tim

TS

Bearing Timeslot

ADD Timesolt GBFDBSC6900 BC(Mand of bearing 510002 atory) channels

Gb Over FR

Bit Field Type

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

TS

Number SET of the Time Slot BTSOML BSC6900 timeslot NO. TS(Mand on the atory) port

GBFD111203

O&M of BSC

Interval Type

1~31

TSBITMA Bearing P time slot

Bearer ADD E1/T1 PPPLNK( BSC6900 port Mandator timeslot of y) PPP link.

GBFD118611 GBFD118622

Abis IP over Bit Field E1/T1 Type A IP over E1/T1

TSBITMA Bearing P time slot

Bearer ADD E1/T1 BSC6900 MPLNK(M port andatory) timeslot of MP link.

GBFD118611 GBFD118622

Abis IP over Bit Field E1/T1 Type A IP over E1/T1

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

ADD BTSPPPL NK(Mand atory) ADD BTSMPL NK(Mand TSBITMA Bearing atory) BSC6900 P Time Slot IMP BTSPPPL NK(Mand atory) IMP BTSMPL NK(Mand atory)

Timeslot of the E1/T1 link carrying the PPP link. The GBFDtimeslot of 118611 an E1 port cannot be used by different PPP links.

Abis IP over E1/T1

Bit Field Type

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

TSC

TSC

The TSC is short for the Training Sequence Code. The TSC must be the same as the BCC. The delay equalizati on is performe ADD d by using GCELLM the GBFDBSC6900 AGRP(Op specified 113701 tional) TSC when the MS or BTS receives the signal. The demodula tion cannot be received because the delay equalizati on cannot be Number of idle timeslots. You can configure up to 128 idle SET timeslots BTSIDLE BSC6900 for the TS(Mand BTS at a atory) time. A BTS can be configure d with up to 512 idle

Frequenc y Hopping (RF Interval hopping, Type baseband hopping)

0~7

TSCOUN Idle TS T Count

GBFD114101 GBFD117301

GPRS Interval Flex Abis Type

0~512

TSCPLA NEN

Whether to allow TSC planning. If this parameter is set to No, the TSC values in SET all MA TSC Plan GCELLS groups of GBFDBSC6900 Enable OFT(Opti the cell 118201 onal) cannot be modified. In this case, the TSC values are automatic ally refreshed to the

SoftSynchroni Enumerati NO(No), zed on Type YES(Yes) Network

ADD Time slot Timeslot TSCROS TSCROS cross BSC6900 cross SX S(Optiona index index l)

None

None

Interval Type

0~65535

STR Duration * TRANSP Duration TSDURA GBFD10 BSC6900 ERFTST( in timeslot T 111207 minutes Mandator mode y) Index of the ADD monitorin BTSMONI GBFDBSC6900 g timeslot. TORTS(O 114701 The index ptional) is unique in a BTS.

BTS Test Interval Function Type

1~144

TSIDX

Timeslot Index

SemiPermane Interval nt Type Connectio n

0~127

TSKN

Task Name

ADD SCHTSK( Mandator y) SET SCHTSK SW(Optio nal) BSC6900 ADD SUBTSK( Optional) ADD SUBCMD (Optional) STR SCHTSK( Optional)

Name of the GBFDscheduled 111203 task.

O&M of BSC

String Type

None

Timeslot TSMASK Mask

Time slots for Ater operation and maintena nce. These ADD time slots ATEROM MRFDBSC6900 are L(Mandat 210301 provided ory) by the ports connecte d to the Ater connectio n path.

Configura tion Bit Field Managem Type ent

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

TSMASK TS Mask

ADD BTSABIS HDLCPA TH(Mand atory) BSC6900 ADD BTSTOP CONFIG( Mandator y)

The 64 kbit/s timeslots on the MRFDport are 211501 numbered from 1 to 31.

IP-Based 2G/3G CoTransmis Bit Field sion on Type Base Station Side

TSN

Tail Slot No.

ADD BTSRXU CHAIN(M andatory) BSC6900 CBN BTSRXU CHAIN(M andatory)

Number of the slot where the main board of the RXU GBFDring is 111202 located. The slot No. is unique in the same BTS.

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

O&M of BTS

Interval Type

0~23

TSNO

Timeslot No.

Timeslot ADD number of GBFDBSC6900 PBSL(Ma Pb 111203 ndatory) signaling link

O&M of BSC

Interval Type

1~31

TSPRIOR Timeslot ITY Priority

Assignme nt priority level of the channel. SET If this GTRXCH GBFDBSC6900 parameter AN(Optio 111005 is less, nal) the assignme nt priority level of the

Enhanced Channel Interval Assignme Type nt Algorithm

0~7

Timeslot TSPWRR Power ESERVE Reserve

Maximum degree by which the output power of the multiSET density GTRXDE TRX GBFDBSC6900 V(Optiona board can 111005 l) exceed the maximum output power within a short time

Enhanced Channel Interval Assignme Type nt Algorithm

0~50

Fast flux measure ment duration. Normal flux measure SET Fast Flux ment is TSRAPID BSCPSS Measure performe GBFDADJPERI BSC6900 OFTPAR ment TBF d after the 119501 OD A(Optiona Timer fast flux l) measure ment lasts over the period specified by this parameter

Adaptive Adjustme nt of Interval Uplink Type and Downlink Channels

0~65535

Whether to enable fast flux detection. When this parameter SET is set to TSRAPID Fast Flux BSCPSS Open, GBFDADJSWIT Detection BSC6900 OFTPAR fast 119501 CH Switch A(Optiona timeslot l) adjustme nt is possible after the TBF is set up.

Adaptive Adjustme Close(Clo nt of Enumerati se), Uplink on Type Open(Op and en) Downlink Channels

TSRATE

ADD Time Slot BTSMONI BSC6900 Rate TORTS(M andatory)

Rate of the GBFDmonitorin 114701 g timeslot

Semi8K(8K), Permane Enumerati 16K(16K), nt on Type 32K(32K), Connectio 64K(64K) n

TSRN

Tail Subrack No.

ADD BTSRXU CHAIN(M andatory) BSC6900 CBN BTSRXU CHAIN(M andatory)

Number of the subrack where the main board of the RXU GBFDring is 111202 located. The subrack No. is unique in the same BTS.

O&M of BTS

Interval Type

0~254

TSTMOD Test E Mode

STR BTSTST( Test BSC6900 Mandator mode y)

GBFD111207

TRXLOO PBACK(T RX Loopback Test), CHLLOO PBACK(C hannel Loopback BTS Test Enumerati Test), Function on Type CHLCOD EC(Speec h codec Test), CPRILOO PBACK(C PRI Loopback Test)

TSTTIME Test SLOT Timeslot

STR TRANSP Test BSC6900 ERFTST( timeslot Mandator y)

GBFD111202

O&M of BTS

Interval Type

0~31

STR Type of BTSBATT TSTTYPE Test Type BSC6900 battery TST(Man test datory)

GBFD111207

SIMPLET EST(Simp BTS Test Enumerati le Test), Function on Type MANUAL TEST(Ma nual Test) PIM(Passi ve Enumerati Intermodu on Type lation Test)

STR BTSRFTS TSTTYPE Test Type BSC6900 T(Mandat ory)

Test Type. PIM:passi GBFDve 111202 intermodu lation test.

O&M of BTS

Allow TsTurning Turning OffEnable Off Time Slot

This parameter specifies whether to allow the BTS to enable the TRX Intelligent Shutdown on Timeslot Level feature. When this SET parameter BSCDST is set to GBFDBSC6900 PA(Optio YES and 111603 nal) the BTS supports this feature, the BTS will periodicall y report the number of times that the TRX is shut down on the timeslot

TRX Power Amplifier Intelligent Enumerati NO(No), Shutdown on Type YES(Yes) on Timeslot Level

TT

Topo Type

ADD BTSRXU BSC6900 CHAIN(M andatory)

TTL

Time to Live

PING BSC6900 IP(Option al)

TTL

TRC MAC(Opti onal) PKT TTL BSC6900 TRC BTSCFM( Optional)

RXU topology type, that is, RXU ring topology or RXU chain topology. In the case of the ring topology, the optical ports of the head and tail boards must be specified. In the case of the chain topology, only the optical port of the head TTL(Time to Live) of the PING packet Indicates the live time of the packet for CFM link tracing detection

GBFD111202

O&M of BTS

CHAIN(C Enumerati hain), on Type RING(Rin g)

None

None

Interval Type

1~255

None

None

Interval Type

1~128

Dyn. Turning TURNOF Off Cell FCELLCH Busy ANNUM Channel Num.

If the number of channels (including PDCH and TCH) occupied on a cell SET that can GCELLD be GBFDBSC6900 YNTURN disabled 111610 OFF(Opti is lower onal) than this threshold, the procedure for disabling the cell can be triggered.

Dynamic Interval Cell Type Power Off

0~8

This parameter specifies SET Dyn. the end TURNOF GCELLD Turning time of a GBFDFCELLST BSC6900 YNTURN Off Cell period 111610 PTIME OFF(Opti Stop Time during onal) which the cell is disabled.

Dynamic Compoun HOUR, Cell d Type MINUTE Power Off

Dyn. TURNOF Turning FCELLST Off Cell RTIME Start Time

This parameter specifies SET the start GCELLD time of a GBFDBSC6900 YNTURN period 111610 OFF(Opti during onal) which the cell is disabled.

Dynamic Compoun HOUR, Cell d Type MINUTE Power Off

Enable TURNOF Turning FENABLE Off Cell

This parameter specifies whether to enable the Dynamic Cell Power Off feature. When this parameter is set to ENABLE, the BSC SET can GCELLD GBFDdisable BSC6900 YNTURN 111610 the cell OFF(Man within the datory) period of time specified by "TURNOF FCELLST RTIME" and "TURNOF FCELLST PTIME"; When this parameter is set to DISABLE, When the

DISABLE( Disable), Dynamic ENABLE( Enumerati Cell Enable), on Type Power Off SLEEPIN G(Sleepin g)

load of the same coverage cell is Dyn. SET higher TURNON Turning GCELLD than this GBFDCELLLOA On Cell BSC6900 YNTURN threshold 111610 DTHRD Load OFF(Opti for a Threshold onal) period, the disabled cell is enabled.

Dynamic Interval Cell Type Power Off

0~100

TUTHD

Temperat ure alarm upper threshold. If the temperatu re of the battery is higher than the value of this parameter , an alarm indicating Temperat SET the ure Alarm BTSAPM abnormal GBFDBSC6900 Upper UBP(Opti temperatu 111202 Threshold onal) re is reported. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon

O&M of BTS

Interval Type

40~79

TUTHD

Temperat SET ure Alarm BTSDHE BSC6900 Upper UBP(Opti Threshold onal)

Observati on Cell ADD TWFCMC Channel BSC6900 AISSCFG HIDLE Reservati (Optional) on Timer

Temperat ure upper threshold of the cabinet. When the cabinet temperatu re is higher than this parameter , an alarm indicating the abnormal cabinet temperatu re is reported. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon Value of the timer for reserving the channels in the observed cell Value of the timer for reserving the TRXs in the observed cell Value of the timer for reserving the TCHFs in the serving

GBFD111202

O&M of BTS

Interval Type

-99~99

GBFD118201

SoftSynchroni Interval zed Type Network

1~60

Observati on Cell ADD TWFCMT TRX BSC6900 AISSCFG RXIDLE Reservati (Optional) on Timer

GBFD118201

SoftSynchroni Interval zed Type Network

1~60

Serving Cell ADD TWFCSC TCHF BSC6900 AISSCFG HIDLE Reservati (Optional) on Timer

GBFD118201

SoftSynchroni Interval zed Type Network

1~60

Value of the timer Informatio for waiting n ADD for the TWFRRM GBFDCollection BSC6900 AISSCFG response RSP 118201 Response (Optional) to Timer informatio n collection MS TWFSEE Search KMS Timer Value of the timer ADD for GBFDBSC6900 AISSCFG searching 118201 (Optional) for the MS

SoftSynchroni Interval zed Type Network

1~60

SoftSynchroni Interval zed Type Network

1~60

Value of the timer BTS for Reserved ADD activating TWFSYN GBFDResource BSC6900 AISSCFG the CACK 118201 Activation (Optional) reserved Timer resources of the BTS of Value the timer for waiting BTS ADD for the TWFSYN SYNC_R GBFDBSC6900 AISSCFG synchroni CRPT EPORT 118201 (Optional) zation Timer report from the BTS

SoftSynchroni Interval zed Type Network

1~60

SoftSynchroni Interval zed Type Network

1~60

TX

TXinteger

Tx-integer (T for short). This parameter specifies the number of timeslots between two transmissi ons when an MS sends SET multiple GCELLID consecuti BSC6900 LEBASIC( ve Optional) channel requests. The access algorithm is defined in GSM Rec. 04.08 to reduce the collisions on the RACH and improve The

GBFD111003 GBFD110301

TX_3(3), TX_4(4), TX_5(5), TX_6(6), TX_7(7), TX_8(8), TX_9(9), TX_10(10 ), Radio TX_11(11 Common ), Channel TX_12(12 Enumerati Managem ), on Type ent TX_14(14 Location ), Updating TX_16(16 ), TX_20(20 ), TX_25(25 ), TX_32(32 ), TX_50(50 )

maximum Assigned power SET Power of that TXAOPE BTSRXU GBFDPass A BSC6900 operators R1 BP(Optio 118701 Operators 1 can use nal) 1 on pass A of MRRU board. The maximum Assigned power SET Power of that TXAOPE BTSRXU GBFDPass A BSC6900 operators R2 BP(Optio 118701 Operators 2 can use nal) 2 on pass A of MRRU board. The maximum Assigned power SET Power of that TXAOPE BTSRXU GBFDPass A BSC6900 operators R3 BP(Optio 118701 Operators 3 can use nal) 3 on pass A of MRRU board.

RAN Sharing

Interval Type

0~10000

RAN Sharing

Interval Type

0~10000

RAN Sharing

Interval Type

0~10000

The maximum Assigned power SET Power of that TXAOPE BTSRXU GBFDPass A BSC6900 operators R4 BP(Optio 118701 Operators 4 can use nal) 4 on pass A of MRRU board. The maximum Assigned power SET Power of that TXBOPE BTSRXU GBFDPass B BSC6900 operators R1 BP(Optio 118701 Operators 1 can use nal) 1 on pass B of MRRU board. The maximum Assigned power SET Power of that TXBOPE BTSRXU GBFDPass B BSC6900 operators R2 BP(Optio 118701 Operators 2 can use nal) 2 on pass B of MRRU board. The maximum Assigned power SET Power of that TXBOPE BTSRXU GBFDPass B BSC6900 operators R3 BP(Optio 118701 Operators 3 can use nal) 3 on pass B of MRRU board. The maximum Assigned power SET Power of that TXBOPE BTSRXU GBFDPass B BSC6900 operators R4 BP(Optio 118701 Operators 4 can use nal) 4 on pass B of MRRU board. ADD Forward Transmit IPPATH( GBFDBandwidt BSC6900 bandwidth Mandator 118605 h of IP path y)

RAN Sharing

Interval Type

0~10000

RAN Sharing

Interval Type

0~10000

RAN Sharing

Interval Type

0~10000

RAN Sharing

Interval Type

0~10000

RAN Sharing

Interval Type

0~10000

TXBW

IP QOS

Interval Type

1~300000 0

TxBw

ADD Forward RSCGRP Transmit GBFDBandwidt BSC6900 (Mandator bandwidth 118605 h y)

IP QOS

Interval Type

0~400000 0

TXINT

Indicates the PING interval Interval of BSC6900 IP(Option between None send[ms] al) the two sent PING Extension transmissi on timeslots of random access. This parameter SET determine GCELLP GBFDBSC6900 s the RACH(Op 119110 interval of tional) sending another channel request after the MS fails to request a

None

Interval Type

200~1000 0

TXINT

TX_INT

Access

T_2(2), T_3(3), T_4(4), T_5(5), T_6(6), T_7(7), T_8(8), Enumerati T_9(9), on Type T_10(10), T_12(12), T_14(14), T_16(16), T_20(20), T_25(25), T_32(32), T_50(50)

TYPE

Subrack Type

ADD Type of SUBRAC BSC6900 the K(Mandat subrack ory)

MRFD210301

Configura tion Enumerati EPS, TCS Managem on Type ent

TYPE

Finish Type

Explanati on of the finish type of the batch command s 1. ANY_ER R_RETU RN: If there is a command whose execution RUN fails, the BATCHFI execution GBFDBSC6900 LE(Mand of the 111203 atory) batch command s is stopped and the execution of the file fails. 2. ALL_END _RETUR N: If all command s in the batch file are

O&M of BSC

ANY_ER R_RETU RN(Stop Enumerati at Error), on Type ALL_END _RETUR N(Stop at End)

TYPE

Freq. Band

This parameter specifies the frequency band of new cells. Each new cell can be allocated frequenci es of only one frequency band. ADD Once the GBFDBSC6900 GCELL(M frequency 110101 andatory) band is selected, it cannot be changed. GSM900: The cell supports GSM900 frequency band. DCS1800 : The cell supports DCS1800 frequency SET BSCPCU Type of BSC6900 TYPE(Ma the PCU ndatory)

GSM900, DCS1800 , GSM900_ DCS1800 Frequenc Enumerati , y Band on Type GSM850, PCS1900, GSM850_ 1800, GSM850_ 1900

TYPE

PCU Type

GBFD114101

GPRS

OUTER(E xternal Enumerati PCU), on Type INNER(B uilt-in PCU)

TYPE

Freq. Band

Frequenc y band to which the newly added cell belongs. Only one frequency band can be selected as the frequency band of ADD each new BTSAUT GBFDBSC6900 cell and it OPLAN(M 510701 cannot be andatory) changed after the selection. To modify the frequency band of the new cell, you must delete the cell and then add it again.

Compact GSM900, BTS DCS1800 Automatic Enumerati , Configura on Type GSM850, tion and PCS1900 Planning

TYPE

Cabinet Type

ADD BTSCABI Type of a GBFDBSC6900 NET(Opti cabinet 111202 onal)

O&M of BTS

BTS30(B TS30), BTS312( BTS312), BTS3001 C(BTS30 01C), BTS3001 CP(BTS3 001CP), BTS3002 C(BTS30 02C), BTS3012 A(BTS30 12A), Enumerati BTS3006 on Type A(BTS30 06A), BTS3012( BTS3012) , BTS3006 C(BTS30 06C), BTS3002 E(BTS30 02E), BTS3012 AE(BTS3 012AE), BTS3012 _II(BTS30 12 II),

TYPE

Cell type. Currently, the fast BTS ADD constructi GCELLQ on is GBFDCell Type BSC6900 UICKSET available 111202 UP(Mand for only atory) GSM900 and DCS1800 cells. SET Up0 BTSANTF Power BSC6900 EEDERC Attenuatio ONNECT( n Factor Optional) Power attenuatio GBFDn factor of 111202 uplink tributary 0

O&M of BTS

GSM900( GSM900), Enumerati DCS1800 on Type (DCS180 0)

U0GEN

O&M of BTS

Interval Type

0~15

U0TOW

Up0 TowerTop Amplifier Flag

SET BTSANTF BSC6900 EEDERC ONNECT( Optional)

Whether there is a GBFDTMA on 111202 uplink tributary 0 Index of uplink tributary 0. Each uplink tributary can be configure d with a maximum of 12 TRXs. This parameter indicates the serial number of a TRX on the uplink tributary. TRX board pass number connecte d to uplink tributary 0

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

U0TRX

SET BTSANTF Up0 Link BSC6900 EEDERC No. ONNECT( Optional)

GBFD111202

O&M of BTS

1(1), 2(2), 3(3), 4(4), 5(5), 6(6), Enumerati 7(7), 8(8), on Type 9(9), 10(10), 11(11), 12(12)

U0TRXB PN

SET Up0 TRX BTSANTF Board BSC6900 EEDERC Pass No. ONNECT( Optional)

GBFD111202

O&M of BTS

Interval Type

0~1,255

U0TRXS N

SET BTSANTF Up0 TRX BSC6900 EEDERC Slot No. ONNECT( Optional)

Number of the slot where the TRX GBFDboard that 111202 connects to uplink tributary 0 is located Number of the subrack where the TRX GBFDboard that 111202 connects to uplink tributary 0 is located

O&M of BTS

Interval Type

0~23,255

U0TRXS RN

SET Up0 TRX BTSANTF Subrack BSC6900 EEDERC No. ONNECT( Optional)

O&M of BTS

Interval Type

0~53,255

U1GEN

SET Up1 BTSANTF Power BSC6900 EEDERC Attenuatio ONNECT( n Factor Optional)

Power attenuatio GBFDn factor of 111202 uplink tributary 1

O&M of BTS

Interval Type

0~15

U1TOW

Up1 TowerTop Amplifier Flag

SET BTSANTF BSC6900 EEDERC ONNECT( Optional)

Whether there is a GBFDTMA on 111202 uplink tributary 1 Index of uplink tributary 1. Each uplink tributary can connect to a maximum of 12 TRXs. This parameter indicates the serial number of a TRX on the uplink tributary. TRX board pass number connecte d to uplink tributary 1

O&M of BTS

NO(NO), Enumerati YES(YES on Type )

U1TRX

SET BTSANTF Up1 Link BSC6900 EEDERC No. ONNECT( Optional)

GBFD111202

O&M of BTS

1(1), 2(2), 3(3), 4(4), 5(5), 6(6), Enumerati 7(7), 8(8), on Type 9(9), 10(10), 11(11), 12(12)

U1TRXB PN

SET Up1 TRX BTSANTF Board BSC6900 EEDERC Pass No. ONNECT( Optional)

GBFD111202

O&M of BTS

Interval Type

0~1,255

U1TRXS N

SET BTSANTF Up1 TRX BSC6900 EEDERC Slot No. ONNECT( Optional)

Number of the slot where the TRX GBFDboard that 111202 connects to uplink tributary 1 is located

O&M of BTS

Interval Type

0~23,255

U1TRXS RN

SET Up1 TRX BTSANTF Subrack BSC6900 EEDERC No. ONNECT( Optional)

CS SET ucCSPref Preferred CSABISC CallReest Call BSC6900 ONGCTR Prio Reestabli L(Optiona sh Priority l)

CS SET Preferred ucCSPref CSABISC CS CSEmerg BSC6900 ONGCTR Emergenc CallPrio L(Optiona y Call l) Priority

Number of the subrack where the TRX board that connects to uplink tributary 1 is located Service priority of call reestablis hment when CS services are preferred. This parameter is used for the flow control in the case of Abis over Service priority of the CS emergenc y call when CS services are preferred. This parameter is used for the flow control in the case of Abis over

GBFD111202

O&M of BTS

Interval Type

0~53,255

GBFD118601

Abis over Interval IP Type

0~15

GBFD118601

Abis over Interval IP Type

0~15

SET CS ucCSPref CSABISC Preferred CSOrgCal BSC6900 ONGCTR CS MOC lPrio L(Optiona Priority l)

SET CS ucCSPref CSABISC Preferred CSTermC BSC6900 ONGCTR CS MTC allPrio L(Optiona Priority l)

CS SET ucCSPrefI Preferred CSABISC nBscHoPr Into-BSC BSC6900 ONGCTR io HO L(Optiona Priority l)

Service priority of the CS MSoriginated call when CS services are preferred. This parameter is used for the flow control in the case of Abis Service priority of the CS MSterminate d call when CS services are preferred. This parameter is used for the flow control in the case of Abis Service priority of the incoming BSC handover when CS services are preferred. This parameter is used for the flow control in the case of Abis over

GBFD118601

Abis over Interval IP Type

0~15

GBFD118601

Abis over Interval IP Type

0~15

GBFD118601

Abis over Interval IP Type

0~15

CS SET ucCSPrefI Preferred CSABISC ntraBscH Intra-BSC BSC6900 ONGCTR oPrio HO L(Optiona Priority l)

CS SET Preferred CSABISC ucCSPref Other BSC6900 ONGCTR OtherPrio Service L(Optiona Priority l)

SET CS CSABISC ucCSPref Preferred BSC6900 ONGCTR PSPrio PS L(Optiona Priority l)

Service priority of the intraBSC handover when CS services are preferred. This parameter is used for the flow control in the case of Abis over Priority of other services when CS services are preferred. This parameter is used for the flow control in the case of Abis over PS service priority when CS services are preferred. This parameter is used for the flow control in the case of Abis

GBFD118601

Abis over Interval IP Type

0~15

GBFD118601

Abis over Interval IP Type

0~15

GBFD118601

Abis over Interval IP Type

0~15

SET CS ucCSPref CSABISC Preferred SupplePri BSC6900 ONGCTR Suppleme o L(Optiona nt Priority l)

SET CS CSABISC ucCSPref Preferred BSC6900 ONGCTR VBSPrio VBS L(Optiona Priority l)

SET CS ucCSPref CSABISC Preferred VGCSPri BSC6900 ONGCTR VGCS o L(Optiona Priority l)

Priority of suppleme ntary services when CS services are preferred. This parameter is used for the flow control in the case of Abis over VBS service priority when CS services are preferred. This parameter is used for the flow control in the case of Abis over VGCS service priority when CS services are preferred. This parameter is used for the flow control in the case of Abis over

GBFD118601

Abis over Interval IP Type

0~15

GBFD118601

Abis over Interval IP Type

0~15

GBFD118601

Abis over Interval IP Type

0~15

In A over IP, if the parameter is set to ON, the circuit IE in the A interface extended signaling must be Controllin SET processe g of CIC ucCtrlOfC MSGSOF d in the GBFDIE In BSS BSC6900 icIE TPARA(O same way 118602 Map ptional) as that in Messages A over non-IP. Otherwise , the A interface extended signaling cannot carry circuittype IE.

A over IP

Enumerati OFF(Off), on Type ON(On)

Whether the BSC selects SET the TCHs UCISRAI RAI Alarm OTHSOF GBFDBSC6900 on the link FAULT Switch TPARA(O 111005 that ptional) reports an RAI alarm.

Enhanced Channel Enumerati NO(No), Assignme on Type YES(Yes) nt Algorithm

PS Reestabli Preferred SET sh service ucPSPref Call PSPREF priority of GBFDCallReest Reestabli BSC6900 ABISCON a PS 118601 Prio sh GCTRL(O preferred Service ptional) call Priority

Abis over Interval IP Type

0~15

CS PS emergenc Preferred SET y call ucPSPref CS PSPREF service CSEmerg Emergenc BSC6900 ABISCON priority of CallPrio y Call GCTRL(O a PS Service ptional) preferred Priority call CS PS original Preferred SET call ucPSPref CS PSPREF service CSOrgCal Original BSC6900 ABISCON priority of lPrio Call GCTRL(O a PS Service ptional) preferred Priority call CS PS terminate Preferred SET d call ucPSPref CS PSPREF service CSTermC Terminate BSC6900 ABISCON priority of allPrio d Call GCTRL(O a PS Service ptional) preferred Priority call BSC PS SET handover Preferred ucPSPrefI PSPREF service In nBscHoPr BSC6900 ABISCON priority of Handover io GCTRL(O a PS Service ptional) preferred Priority call

GBFD118601

Abis over Interval IP Type

0~15

GBFD118601

Abis over Interval IP Type

0~15

GBFD118601

Abis over Interval IP Type

0~15

GBFD118601

Abis over Interval IP Type

0~15

BSC intra PS SET handover Preferred ucPSPrefI PSPREF service Intra GBFDntraBscH BSC6900 ABISCON priority of Handover 118601 oPrio GCTRL(O a PS Service ptional) preferred Priority call Other PS SET service Preferred PSPREF ucPSPref priority of GBFDOther BSC6900 ABISCON OtherPrio a PS 118601 Service GCTRL(O preferred Priority ptional) call PS PS SET service Preferred PSPREF ucPSPref priority of GBFDPS BSC6900 ABISCON PSPrio a PS 118601 Service GCTRL(O preferred Priority ptional) call Suppleme PS SET nt service ucPSPref Preferred PSPREF priority of GBFDSupplePri Suppleme BSC6900 ABISCON a PS 118601 o nt Service GCTRL(O preferred Priority ptional) call

Abis over Interval IP Type

0~15

Abis over Interval IP Type

0~15

Abis over Interval IP Type

0~15

Abis over Interval IP Type

0~15

VBS PS SET service Preferred PSPREF ucPSPref priority of GBFDVBS BSC6900 ABISCON VBSPrio a PS 118601 Service GCTRL(O preferred Priority ptional) call VGCS PS SET service ucPSPref Preferred PSPREF priority of GBFDVGCSPri VGCS BSC6900 ABISCON a PS 118601 o Service GCTRL(O preferred Priority ptional) call In case of intraBSC, if this parameter is set to Speech ON, the Ver SET ucSpeech same Change AITFOTH GBFDVerOptiIn BSC6900 channel Optimize PARA(Op 118602 Ho type and in tional) voice Handover version as those of the original channel are

Abis over Interval IP Type

0~15

Abis over Interval IP Type

0~15

A over IP

Enumerati OFF(Off), on Type ON(On)

Receive UDPMUX UDP MODREC MUX V Mode

UDP multiplexi ng mode of the receiving party. The mode that does not support the function of compress ing the RTP header ADD indicates BSC6900 IPMUX(M that the andatory) receiving party supports the UDP MUX RTP header but not the function of compress ing the RTP header. The mode that

GBFD118604 GBFD118610

Abis MUX UDP NORTPC MUX for Enumerati OMP, A on Type RTPCOM Transmis P sion

UDP multiplexi ng mode of the sending party. If the mode that does not support the function of compress ing the Sender RTP UDPMUX ADD UDP header MODSEN BSC6900 IPMUX(M MUX indicates D andatory) Mode that the sending party supports the UDP MUX RTP header but not the function of compress ing the RTP header. The mode UDP port number of the local NSVL. When "Subnet Protocol Type" of NSE is "Gb over IP" and ADD "Subnetw Local NSVLLO ork UDPPN UDP Port BSC6900 CAL(Man Configure No. datory) Mode" is "Static", the setting of this parameter must be consistent with the setting at the SGSN side.

GBFD118604 GBFD118610

Abis MUX UDP NORTPC MUX for Enumerati OMP, A on Type RTPCOM Transmis P sion

GBFD118603

Gb over IP

Interval Type

1214~200 1,2005~3 783,3786 ~4783,47 85~65000

UDPPN

ADD Remote NSVLRE UDP Port BSC6900 MOTE(Ma No. ndatory)

UG

ADD Operator BSC6900 OP(Optio Level nal)

Upper SET UHUMTH Humidity BSC6900 BTSEXD( D Threshold Optional)

UDP port number of the remote NSVL. The setting of this parameter must be consistent with the setting at the SGSN Group to which the operator belongs. This parameter is used to limit the right of the operator. Upper humidity threshold for the environm ent alarm box to report an alarm indicating that the ambient humidity is too high. If the ambient humidity of the BTS is higher than this threshold, the environm ent alarm box reports the alarm. In multimode scenario, the value of this

GBFD118603

Gb over IP

Interval Type

0~65535

GBFD111203 MRFD210305

Administr ators(Ad ministrato r), O&M of Operators BSC Enumerati (Operator Security on Type ), Managem Users(Us ent er), Guests(G uest), Customs(

GBFD111202

O&M of BTS

Interval Type

0~99

UIC

UIC

SET GCELLG BSC6900 SMR(Opti onal)

UINTTIM Unit E time[ms]

STR BSC6900 E1T1TST (Optional)

Used to identify the uplink access message from the MS. The value 64 is invalid. Unit time for the error code ratio test

GBFD510301 GBFD510302

Public Voice Group Call Interval Service Type Public Voice Broadcast Service None Interval Type

0~64

None

300~1000

UL

Upper Limit

SET ALMPOR BSC6900 T(Optiona l)

Upper limit for MRFDtriggering 210304 an alarm

Faulty String Managem Type ent

None

UL

Upper Limit

Upper limit of the SET alarm. BTSENV MRFDThis BSC6900 ALMPOR parameter 210304 T(Optiona is valid for l) the analog

Faulty String Managem Type ent

None

Minimum interval between SET two ULADJPR PwrCtrlUL GCELLP consecuti GBFDBSC6900 D AdjPeriod WR3(Opti ve uplink 117601 onal) power control command s

HUAWEI III Power Interval Control Type Algorithm

0~255

Current call is an AMR fullrate call, and when the uplink ULAFSR SET receive ULAFSRe EXQUAL GCELLP quality is GBFDxQualHig BSC6900 HIGHTHR WR3(Opti greater 117601 hThred ED onal) than the threshold, Huawei III power control is performe d.

HUAWEI III Power Interval Control Type Algorithm

1~30

Current call is an AMR fullrate call, and when the uplink ULAFSR SET receive ULAFSRe EXQUAL GCELLP quality is GBFDxQualLow BSC6900 LOWTHR WR3(Opti lower 117601 Thred ED onal) than the threshold, Huawei III power control is performe d.

HUAWEI III Power Interval Control Type Algorithm

1~30

Current call is an AMR halfrate call, and when the uplink ULAHSR SET receive ULAHSR EXQUAL GCELLP quality is GBFDexQualHi BSC6900 HIGHTHR WR3(Opti greater 117601 ghThred ED onal) than the threshold, Huawei III power control is performe d.

HUAWEI III Power Interval Control Type Algorithm

1~30

Current call is an AMR halfrate call, and when the uplink ULAHSR SET receive ULAHSR EXQUAL GCELLP quality is GBFDexQualLo BSC6900 LOWTHR WR3(Opti lower 117601 wThred ED onal) than the threshold, Huawei III power control is performe d.

HUAWEI III Power Interval Control Type Algorithm

1~30

ULBQLA STTIME

UL BQ HO Last Time

ADD G2GNCE BSC6900 LL(Option al)

ADD UL BQ ULBQST G2GNCE HO Static BSC6900 ATTIME LL(Option Time al)

The P/N criterion must be met for triggering a UL BQ handover. That is, the UL BQ handover can be triggered only if P measure ment reports among N measure ment reports meet the triggering conditions . This parameter correspon ds to P in The P/N criterion must be met for triggering a UL BQ handover. That is, the UL BQ handover can be triggered only if P measure ment reports among N measure ment reports meet the triggering conditions . This parameter correspon ds to N in

GBFD510501

HUAWEI Interval II Type Handover

1~8

GBFD510501

HUAWEI Interval II Type Handover

1~8

SET ULCOEF Fast UL BSCPSS FICIENTT Priority BSC6900 OFTPAR SRAPIDA Decision A(Optiona DJ Threshold l)

SET Timer for ULDATAF GCELLT UL Data BSC6900 WDTMR MR(Optio Forward nal)

If the ratio of uplink flux to downlink flux is greater than or equal to the threshold during the fast flux measure ment, the uplink services takes priority. Duration for uplink data transmissi on on the original channel if the TC resources are changed before and after the handover Number

GBFD119501

Adaptive Adjustme nt of Interval Uplink Type and Downlink Channels

1~255

GBFD111203

O&M of BSC

Interval Type

0~240

of RRBP SET downlink Frequenc BSCPSS GRPS ulDlAckFr y for GBFDBSC6900 OFTPAR TBF RLC eq GPRS 119105 A(Optiona blocks Downlink l) sent TBF before RRBP

RLC Mode

Interval Type

1~64

If the UL receive level remains lower than the Edge HO SET "Edge HO ULEDGE UL GCELLH UL BSC6900 THRES RX_LEV OBASIC( RX_LEV Threshold Optional) Threshold " for a period, the edge handover is triggered.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

RRBP SET Frequenc BSCPSS ulEgprsDl y for BSC6900 OFTPAR AckFreq EGPRS A(Optiona Downlink l) TBF ACK SET Frequenc BSCPSS ulEgprsUl y for BSC6900 OFTPAR AckFreq EGPRS A(Optiona Uplink l) TBF

Number of downlink GRPS TBF RLC blocks sent before RRBP Period of acknowle dging the EGPRS TBF RLC uplink data block

GBFD119105

RLC Mode

Interval Type

1~64

GBFD119105

RLC Mode

Interval Type

1~64

III UL ULFILTA Filter DJFACT Adjust OR Factor

Filter adjustme nt factor for uplink power control. If this parameter is set to a large value, the filtered values become smooth, SET thus GCELLP reducing GBFDBSC6900 WR3(Opti the 117601 onal) impact of poor measure ment reports on the filtered values. If this parameter is set to a small value, the filter values are close

HUAWEI III Power Interval Control Type Algorithm

1~10

Current call is a full-rate call, and when the uplink ULFSRE SET receive ULFSRex XQUALHI GCELLP quality is GBFDQualHigh BSC6900 GHTHRE WR3(Opti greater 117601 Thred D onal) than the threshold, Huawei III power control is performe d.

HUAWEI III Power Interval Control Type Algorithm

1~30

Current call is a full-rate call, and when the uplink ULFSRE SET receive ULFSRex XQUALL GCELLP quality is GBFDQualLowT BSC6900 OWTHRE WR3(Opti lower 117601 hred D onal) than the threshold, Huawei III power control is performe d.

HUAWEI III Power Interval Control Type Algorithm

1~30

Current call is a half-rate call, and when the uplink ULHSRE SET receive ULHSRex XQUALHI GCELLP quality is GBFDQualHigh BSC6900 GHTHRE WR3(Opti greater 117601 Thred D onal) than the threshold, Huawei III power control is performe d.

HUAWEI III Power Interval Control Type Algorithm

1~30

Current call is a half-rate call, and when the uplink ULHSRE SET receive ULHSRex XQUALL GCELLP quality is GBFDQualLowT BSC6900 OWTHRE WR3(Opti lower 117601 hred D onal) than the threshold, Huawei III power control is performe d.

HUAWEI III Power Interval Control Type Algorithm

1~30

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding ULHYSTF GCELLC to the GBFDRate BSC6900 1 CAMR(O related 115501 adj.hyst1[ ptional) algorithm. F] The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR FR

Interval Type

0~15

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding ULHYSTF GCELLC to the GBFDRate BSC6900 2 CAMR(O related 115501 adj.hyst2[ ptional) algorithm. F] The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR FR

Interval Type

0~15

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding ULHYSTF GCELLC to the GBFDRate BSC6900 3 CAMR(O related 115501 adj.hyst3[ ptional) algorithm. F] The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR FR

Interval Type

0~15

ULHYST H1

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding GCELLC to the GBFDRate BSC6900 CAMR(O related 115502 adj.hyst1[ ptional) algorithm. H] The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR HR

Interval Type

0~15

ULHYST H2

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding GCELLC to the GBFDRate BSC6900 CAMR(O related 115502 adj.hyst2[ ptional) algorithm. H] The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR HR

Interval Type

0~15

ULHYST H3

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding GCELLC to the GBFDRate BSC6900 CAMR(O related 115502 adj.hyst3[ ptional) algorithm. H] The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR HR

Interval Type

0~15

ULHYST WB1

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding GCELLC to the GBFDRate BSC6900 CAMR(O related 115507 adj.hyst1[ ptional) algorithm. WB] The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

WB AMR

Interval Type

0~15

ULHYST WB2

AMR UL SET Coding GCELLC Rate BSC6900 CAMR(O adj.hyst2[ ptional) WB]

SET 2G Cell GCELLH UlLdrThrd UL Basic BSC6900 OINTERR 2GCell Congest ATLDB(O Thred ptional)

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate according GBFDto the 115507 related algorithm. The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio When the uplink load of a cell is larger than the value of this parameter and is GBFDsmaller 114322 than "2G Cell UL Overload Congest Thred", the uplink of the cell is in the basic congestio

WB AMR

Interval Type

0~15

GSM/WC DMA Interval Load Type Based Handover

1~100

When the network receives measure ment reports, in considera tion of the accuracy of a single measure ment report, the measure ment Filter SET values in ULLEVFI Length for GCELLP certain GBFDBSC6900 LTLEN UL WR2(Opti measure 110703 RX_LEV onal) ment reports are filtered to represent the radio operating environm ent. This parameter specifies the number of measure ment reports

Enhanced Power Interval Control Type Algorithm

1~20

Maximum permissibl e adjustme SET nt step ULMAXD ULMAXD GCELLP when the GBFDOWNSTE BSC6900 ownStep WR3(Opti BSC 117601 P onal) decrease s the uplink transmit power

HUAWEI III Power Interval Control Type Algorithm

1~30

Maximum permissibl e adjustme SET nt step ULMAXU ULMAXU GCELLP GBFDBSC6900 when the PSTEP pStep WR3(Opti 117601 BSC onal) increases the uplink transmit power

HUAWEI III Power Interval Control Type Algorithm

1~30

When the uplink load of a cell is 2G Cell SET greater UL GCELLH than the UlOlcThrd GBFDOverload BSC6900 OINTERR value, the 2GCell 114322 Congest ATLDB(O uplink of Thred ptional) the cell is in the overload congestio n status.

GSM/WC DMA Interval Load Type Based Handover

1~100

After the BSC delivers the power control command , it should wait for a certain period before affirming the effect of the power SET control. UL MR. ULPRED GCELLP Therefore GBFDNumber BSC6900 LEND WR2(Opti , the MR 110703 Predicted onal) that power control decision is based on cannot accurately reflect the radio environm ent during the power adjustme nt, but misses the latest

Enhanced Power Interval Control Type Algorithm

0~3

The MS transmit power is decrease d only when the quality level of the MS transmit signal is smaller than the value of the SET parameter UL Qual. GCELLP ULQHIGH GBFD. If (the Upper BSC6900 WRBASI THRED 110703 uplink Threshold C(Optiona receive l) level MAX Up Adj. PC Value by Qual) is smaller than "UL RX_LEV Lower Threshold ", the MS transmit power is not adjusted.

Enhanced Power Interval Control Type Algorithm

0~7

The MS transmit power is increased only when the quality level of the MS transmit signal is greater than the value of the SET parameter UL Qual. GCELLP . If (the ULQLOW GBFDLower BSC6900 WRBASI uplink THRED 110703 Threshold C(Optiona receive l) level + MAX Up Adj. PC Value by Qual) is greater than "UL RX_LEV Upper Threshold ", the MS transmit power is not adjusted.

Enhanced Power Interval Control Type Algorithm

0~7

When the network receives measure ment reports, the measure ment values in several straight measure ment reports SET are Filter ULQUAFI GCELLP filtered to Length for BSC6900 LTLEN WR2(Opti reflect the UL Qual. onal) radio operating environm ent for the sake of accuracy. This parameter specifies the number of measure ment reports sampled for In the case of power control, when the uplink receive quality is not smaller SET than "UL UL Qual. ULQUAL GCELLP Qual. Bad Bad Trig BSC6900 BADTRIG WR2(Opti Trig Threshold onal) Threshold ", the actual "UL RX_LEV Upper Threshold " is increased by "UL Qual. Bad UpLEVDif

GBFD110703

Enhanced Power Interval Control Type Algorithm

1~20

GBFD110703

Enhanced Power Interval Control Type Algorithm

0~7

In the case of power control, when the uplink receive quality is not smaller UL Qual. SET than "UL ULQUAL Bad GCELLP Qual. Bad GBFDBADUPL BSC6900 UpLEVDif WR2(Opti Trig 110703 EV f onal) Threshold ", the actual "UL RX_LEV Upper Threshold " is increased by "UL Qual. Bad UpLEVDif

Enhanced Power Interval Control Type Algorithm

0~63

An emergenc y handover due to bad quality is SET triggered ULQUALI UL Qual. GCELLH when the BSC6900 MIT Threshold OEMG(O uplink ptional) receive quality is not smaller than "UL Qual. Threshold ".

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

The value of this parameter correspon ds to multiplyin g quality level 0 to 7 by 10. An emergenc SET y ULQUALI UL Qual. GCELLA handover MITAMRF Limit for BSC6900 MRQUL( can be R AMR FR Optional) triggered only when the uplink receive quality of the MS is greater than the value of this parameter .

GBFD115501 GBFD510501 GBFD110601

AMR FR HUAWEI II Interval Handover Type HUAWEI I Handover

0~70

The value of this parameter correspon ds to multiplyin g quality level 0 to 7 by 10. An emergenc SET y ULQUALI UL Qual. GCELLA handover MITAMR Limit for BSC6900 MRQUL( can be HR AMR HR Optional) triggered only when the uplink receive quality of the MS is greater than the value of this parameter .

GBFD115502 GBFD510501 GBFD110601

AMR HR HUAWEI II Interval Handover Type HUAWEI I Handover

0~70

This parameter specifies the uplink signal strength factor multiplied by 10 during the calculatio n of the uplink power control SET step. The ULREXLE ULRexLe GCELLP uplink GBFDVADJFCT vAdjustFa BSC6900 WR3(Opti signal 117601 R ctor onal) strength factor is a coefficient indicating how much the signal strength is considere d during the calculatio n of the uplink power control

HUAWEI III Power Interval Control Type Algorithm

0~10

When the network receives measure ment reports, the measure ment values in several straight measure ment reports SET are ULREXLE ULRexLe GCELLP filtered to GBFDVEXPFLT vExponen BSC6900 WR3(Opti reflect the 117601 LEN tFilterLen onal) radio operating environm ent for the sake of accuracy. This parameter specifies the number of measure ment reports sampled for

HUAWEI III Power Interval Control Type Algorithm

0~19

When the uplink receive level SET reaches ULREXLE ULRexLe GCELLP the GBFDVHIGHTH vHighThr BSC6900 WR3(Opti threshold, 117601 RED ed onal) Huawei III power control is performe d.

HUAWEI III Power Interval Control Type Algorithm

0~63

When the uplink receive level is SET lower ULREXLE ULRexLe GCELLP than the GBFDVLOWTH vLowThre BSC6900 WR3(Opti threshold, 117601 RED d onal) Huawei III power control is performe d.

HUAWEI III Power Interval Control Type Algorithm

0~63

When the network receives measure ment reports, the measure ment values in several straight measure ment reports SET are ULREXLE ULRexLe GCELLP filtered to GBFDVSLDWI vSlideWin BSC6900 WR3(Opti reflect the 117601 NDOW dow onal) radio operating environm ent for the sake of accuracy. This parameter specifies the number of measure ment reports sampled for slide-

HUAWEI III Power Interval Control Type Algorithm

1~20

This parameter specifies the uplink quality level factor multiplied by 10 during the calculatio n of the uplink power control SET step. The ULREXQ ULRexQu GCELLP uplink GBFDUALADJF alAdjustF BSC6900 WR3(Opti quality 117601 CTR actor onal) level factor is a coefficient indicating how much the quality level is considere d during the calculatio n of the uplink power control step.

HUAWEI III Power Interval Control Type Algorithm

0~10

When the network receives measure ment reports, the measure ment values in several straight measure ment reports ULRexQu SET are ULREXQ alExpone GCELLP filtered to GBFDUALEXPF BSC6900 ntFilterLe WR3(Opti reflect the 117601 LTLEN n onal) radio operating environm ent for the sake of accuracy. This parameter specifies the number of measure ment reports sampled for

HUAWEI III Power Interval Control Type Algorithm

0~19

When the network receives measure ment reports, the measure ment values in several straight measure ment reports SET are ULREXQ ULRexQu GCELLP filtered to GBFDUALSLD alSlideWi BSC6900 WR3(Opti reflect the 117601 WINDOW ndow onal) radio operating environm ent for the sake of accuracy. This parameter specifies the number of measure ment reports sampled for slide-

HUAWEI III Power Interval Control Type Algorithm

1~20

ULRXLEV PROTEC TFACTO R

III UL RexLev Protect Factor

Signal strength factor for the protective limitation on calculatin g the uplink power control adjustme nt step. SET The GCELLP GBFDBSC6900 calculated WR3(Opti 117601 step value onal) cannot exceed the step value that is obtained on the basis of the signal strength protection factor and the signal quality

HUAWEI III Power Interval Control Type Algorithm

0~100

ULRXQU ALPROT ECTFAC TOR

III UL RexQual Protect Factor

Signal strength factor for the protective limitation on calculatin g the uplink power control adjustme nt step. SET The GCELLP GBFDBSC6900 calculated WR3(Opti 117601 step value onal) cannot exceed the step value that is obtained on the basis of the signal strength protection factor and the signal quality

HUAWEI III Power Interval Control Type Algorithm

0~100

When the uplink receive level SET UL reaches GCELLP ULSSHIG RX_LEV the GBFDBSC6900 WRBASI HTHRED Upper threshold, 110703 C(Optiona Threshold Huawei II l) power control is performe d.

Enhanced Power Interval Control Type Algorithm

0~63

When the uplink receive SET level is UL GCELLP below the ULSSLO RX_LEV GBFDBSC6900 WRBASI threshold, WTHRED Lower 110703 C(Optiona Huawei II Threshold l) power control is performe d.

Enhanced Power Interval Control Type Algorithm

0~63

ULTHF1

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according GBFDCoding GCELLC to the 115501 BSC6900 Rate CAMR(O related GBFDadj.th1[F] ptional) algorithm. 115507 The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR FR Interval WB AMR Type

0~63

ULTHF2

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according GBFDCoding GCELLC to the 115501 BSC6900 Rate CAMR(O related GBFDadj.th2[F] ptional) algorithm. 115507 The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR FR Interval WB AMR Type

0~63

ULTHF3

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according GBFDCoding GCELLC to the 115501 BSC6900 Rate CAMR(O related GBFDadj.th3[F] ptional) algorithm. 115507 The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR FR Interval WB AMR Type

0~63

ULTHH1

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding GCELLC to the GBFDBSC6900 Rate CAMR(O related 115502 adj.th1[H] ptional) algorithm. The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR HR

Interval Type

0~63

ULTHH2

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding GCELLC to the GBFDBSC6900 Rate CAMR(O related 115502 adj.th2[H] ptional) algorithm. The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR HR

Interval Type

0~63

ULTHH3

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding GCELLC to the GBFDBSC6900 Rate CAMR(O related 115502 adj.th3[H] ptional) algorithm. The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

AMR HR

Interval Type

0~63

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding ULTHWB GCELLC to the GBFDRate BSC6900 1 CAMR(O related 115507 adj.th1[W ptional) algorithm. B] The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio

WB AMR

Interval Type

0~63

Based on the RQI in the call measure ment report, the BTS and MS automatic ally adjust the current speech coding rate AMR UL SET according Coding ULTHWB GCELLC to the GBFDRate BSC6900 2 CAMR(O related 115507 adj.th2[W ptional) algorithm. B] The coding rate adjustme nt threshold is the threshold of RQI. The RQI indicates the carriertointerferen ce ratio Whether a UL SET ULTOOL UL to OL subcell to GCELLH GBFDHOALLO HO BSC6900 OL OIUO(Opt 113201 W Allowed subcell ional) handover is allowed Number of uplink GRPS ACK SET TBF RLC Frequenc BSCPSS blocks ulUlAckFr y for GBFDBSC6900 OFTPAR sent eq GPRS 119105 A(Optiona before an Uplink l) acknowle TBF dgement is required

WB AMR

Interval Type

0~63

Concentri Enumerati NO(No), c Cell on Type YES(Yes)

RLC Mode

Interval Type

1~64

Whether the crosstalk optimizati on function over the Um interface is allowed. If this parameter is set to Um YES UMCROS Interface SET when call STALKO Crosstalk GCELLS drops GBFDBSC6900 PTALLO Optimizati OFT(Opti occur on 111203 WED on onal) the Um Allowed interface, this function can avoid crosstalk due to very early assignme nt of the channel that is not released. If this parameter is set to

O&M of BSC

NO(Not Enumerati Allowed), on Type YES(Allo wed)

Timer of penalty on a neighbori ng cell SET UMPENA when a UmPenalt GCELLH LTYTIME BSC6900 handover yTimer OFITPEN R fails due (Optional) to faults of air interface connectio n.

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~255

UmVer

Um Interface Tag

Phase tag for GSM SET protocols BSCBASI MRFDBSC6900 that the C(Optiona 210301 Um l) interface supports

GSM_PH ASE_1, Configura GSM_PH tion Enumerati ASE_2, Managem on Type GSM_PH ent ASE_2Plu s

UNBA

Support Balance

Whether to support the balanced mode or the unbalanc ed mode. When this parameter is set to YES, you can set the DIP switches on the SET interface BSC6900 E1T1(Opti None boards. onal) You do not need to set the DIP switches by turning them inwards or outwards. In this case, an interface board can be made to work Retry in times after the SET peer BSCNSP response GBFDBSC6900 ARA(Opti timer 510002 onal) expires during NSVC unblockin

None

NO(NO), Enumerati YES(YES on Type )

UNBLOC Unblock KRETRY Retry

Gb Over FR

Interval Type

1~6

ANT_A ALD SET UnderCur Under BTSRXU BSC6900 AlmThdA Current BP(Optio Occur nal) Threshold

ANT_B ALD SET UnderCur Under BTSRXU BSC6900 AlmThdB Current BP(Optio Occur nal) Threshold

Abnormall y alarm triggering threshold when the ANT_A tributary antenna current is too light. When the actual current is lower than the configure d value, the ALD Current Abnormall y Alarm is triggered with the correspon ding alarm tributary No. of 1. Abnormall y alarm triggering threshold when the ANT_B tributary antenna current is too light. When the actual current is lower than the configure d value, the ALD Current Abnormall y Alarm is triggered with the correspon ding alarm tributary No. of 1.

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

RET ALD SET UnderCur Under BTSRXU AlmThdR Current BSC6900 BP(Optio ET Occur nal) Threshold

ANT_A ALD SET UnderCur Under BTSRXU BSC6900 ClrThdA Current BP(Optio Clear nal) Threshold

Abnormall y alarm triggering threshold when the RET tributary antenna current is too light. When the actual current is lower than the configure d value, the ALD Current Abnormall y Alarm is triggered with the correspon ding alarm tributary No. of 1. Abnormall y alarm clearance triggering threshold when the ANT_A tributary antenna current is too light. When the actual current is higher than the configure d value, the ALD Current Abnormall y Alarm disappear s with the correspon ding alarm tributary No. of 1.

MRFD210304

Faulty Interval Managem Type ent

10~3500

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

ANT_B ALD SET UnderCur Under BTSRXU BSC6900 ClrThdB Current BP(Optio Clear nal) Threshold

RET ALD SET UnderCur Under BTSRXU ClrThdRE Current BSC6900 BP(Optio T Clear nal) Threshold

Abnormall y alarm clearance triggering threshold when the ANT_B tributary antenna current is too light. When the actual current is higher than the configure d value, the ALD Current Abnormall y Alarm disappear s with the correspon ding alarm tributary No. of 1. Abnormall y alarm clearance triggering threshold when the RET tributary antenna current is too light. When the actual current is higher than the configure d value, the ALD Current Abnormall y Alarm disappear s with the correspon ding alarm tributary No. of 1.

MRFD210304 MRFD210601

Faulty Managem ent Connectio Interval n with Type TMA (Tower Mounted Amplifier)

10~3500

MRFD210304

Faulty Interval Managem Type ent

10~3500

UPBTSID

Up BTS Index

ADD BTSAUT BSC6900 OPLAN(M andatory)

Index of upperlevel BTS GBFDconnecte 111202 d to the BTS

O&M of BTS

Interval Type

0~2047

Dest Father UPBTSID BTS Index

Number of the upperADD level BTS. BTSCON GBFDBSC6900 The NECT(Ma 111202 number is ndatory) unique in a BSC6900. Index type of upperlevel BTS GBFDconnecte 111202 d to the BTS GBFD111202

O&M of BTS

Interval Type

0~2047

ADD UPBTSID UPBTS BTSAUT BSC6900 TYPE Index type OPLAN(M andatory) Dest UPBTSID Father TYPE Index Type ADD BTSCON BSC6900 NECT(Ma ndatory)

O&M of BTS

BYNAME( By Enumerati Name), on Type BYID(By Index) BYNAME( By Enumerati Name), on Type BYID(By Index)

UPBTSN Up BTS AME Name

Index type of the upperlevel BTS Name of the upperlevel BTS connecte d to the BTS. The BTS name is unique within a same BSC6900. This ADD parameter BTSAUT BSC6900 cannot OPLAN(M contain , ; andatory) = " ' more than two (include two) %, more than two (include two) space, more than three (include three) +.

O&M of BTS

GBFD111202

O&M of BTS

String Type

None

Dest UPBTSN Father AME BTS Name

ADD BTSCON BSC6900 NECT(Ma ndatory)

UPDATE Update

ADD GSMSCB BSC6900 (Mandator y)

Name of the upperlevel BTS. The name is unique in a BSC6900. The invalid character s (\, /, :, *, ?, ", <, >, |, and #) cannot appear in the name. Update code for a simple cell broadcast message. This parameter together with "Code" uniquely identifies a cell broadcast message.

GBFD111202

O&M of BTS

String Type

None

GBFD113602

Simplified Interval Cell Type Broadcast

0~15

Uplink UPDEFA Default ULTCS CS Type

Default coding scheme of the uplink GPRS link. If the uplink adopts the dynamic adjustme nt coding scheme, this SET parameter GCELLP can be BSC6900 SCS(Opti used to onal) set the coding scheme for transmissi on during initial access. If the uplink uses the fixed coding scheme, the TBF uses the fixed

GBFD114101 GBFD119106 GBFD114101 GBFD119106

GPRS Coding Scheme GPRS Coding Scheme

CS1(CS1) , CS2(CS2) Enumerati , on Type CS3(CS3) , CS4(CS4)

Uplink UPDEFA Default ULTMCS MCS Type

Default coding scheme of the uplink EDGE link. If the uplink adopts the dynamic adjustme nt coding scheme, this SET parameter GCELLE can be BSC6900 GPRSPA used to RA(Optio set the nal) coding scheme for transmissi on during initial access. If the uplink uses the fixed coding scheme, the TBF uses the fixed

GBFD114201 GBFD119106 GBFD114201 GBFD119106

EGPRS Coding Scheme EGPRS Coding Scheme

MCS1(M CS1), MCS2(M CS2), MCS3(M CS3), MCS4(M CS4), Enumerati MCS5(M on Type CS5), MCS6(M CS6), MCS7(M CS7), MCS8(M CS8), MCS9(M CS9)

Uplink multiplex threshold of dynamic channel conversio n. When the subscribe r number on the channel Uplink reaches Multiplex the value Threshold SET (threshold UPDYNC of GCELLP /10), the HNTRAN BSC6900 Dynamic SCHM(O dynamic LEV Channel ptional) channel Conversio conversio n n applicatio n is triggered. We recomma nd that the value of "Uplink Multiplex Threshold of Dynamic Channel

GBFD114101 GBFD113101 GBFD119303 GBFD119501 GBFD114101 GBFD113101 GBFD119303 GBFD119501

GPRS PDCH Dynamic Adjustme nt Load Sharing Adaptive Adjustme nt of Uplink and Downlink Channels Interval GPRS Type PDCH Dynamic Adjustme nt Load Sharing Adaptive Adjustme nt of Uplink and Downlink Channels

10~70

Default coding scheme used on the uplink EGPRS2A link. If the uplink uses the dynamic coding scheme, this parameter specifies Uplink SET the UPE2AD EGPRS2GCELLE GBFDcoding EFAULT A Default BSC6900 GPRSPA scheme 510803 MCS MCS RA(Optio that is Type nal) used for the transmissi on in initial access. If the uplink uses the fixed coding scheme, the TBF uses the fixed coding

MCS1(M CS1), MCS2(M CS2), MCS3(M CS3), MCS4(M CS4), MCS5(M CS5), Uplink Enumerati MCS6(M EGPRS2on Type CS6), A UAS7(UA S7), UAS8(UA S8), UAS9(UA S9), UAS10(U AS10), UAS11(U AS11)

Fixed coding scheme that is used on the uplink EGPRS2A link. If the uplink uses the fixed coding scheme, Uplink SET this EGPRS2GCELLE parameter UPE2AFI GBFDA Fixed BSC6900 GPRSPA can be XMCS 510803 MCS RA(Optio set to any Type nal) one in MCS1-6 and UAS711. If the uplink uses the dynamic coding scheme, this parameter can be set to UNFIXED

MCS1(M CS1), MCS2(M CS2), MCS3(M CS3), MCS4(M CS4), MCS5(M CS5), MCS6(M Uplink CS6), Enumerati EGPRS2UAS7(UA on Type A S7), UAS8(UA S8), UAS9(UA S9), UAS10(U AS10), UAS11(U AS11), UNFIXED (UNFIXE D)

Inactive SET UPEXTT Period of GCELLP BFINACT Extended BSC6900 RIVATEO DELAY Uplink PTPARA( TBF Optional)

SET Uplink GCELLP UPFIXCS Fixed CS BSC6900 SCS(Opti Type onal)

Inactive period of extended uplink TBF. After the network side receives the last uplink RLC data block (CountVal ue=0) of the MS supportin g the extended uplink TBF, the uplink TBF is not released immediat ely. Instead, the uplink TBF is set to the inactive state. In the inactive Adjustme nt mode of the uplink GPRS link coding scheme. If the fixed coding scheme is used, this parameter is a value ranging from CS1 to CS4. If the dynamic coding scheme is used, this parameter

GBFD119203

Extended Interval Uplink Type TBF

0~5000

GBFD114101 GBFD119106 GBFD114101 GBFD119106

GPRS Coding Scheme GPRS Coding Scheme

CS1(CS1) , CS2(CS2) , CS3(CS3) Enumerati , on Type CS4(CS4) , UNFIXED (UNFIXE D)

Uplink UPFIXMC Fixed S MCS Type

SET GCELLE BSC6900 GPRSPA RA(Optio nal)

SET UPINTER Interf.of GCELLC FQUALLI UL Qual. BSC6900 HMGAD( MIT Threshold Optional)

Coding scheme of the uplink EDGE link. If the uplink uses the fixed coding scheme, this parameter is set to a value ranging from MCS1 to MCS9. If the uplink uses the dynamic adjustme nt coding scheme, this parameter is set to One of the threshold s to determine whether the uplink interferen ce exists. If the uplink level is not smaller than "Interf.of UL Level Threshold " and the uplink quality of the channel is not less than "Interf.of UL Qual. Threshold ", the

GBFD114201 GBFD119106 GBFD114201 GBFD119106

EGPRS Coding Scheme EGPRS Coding Scheme

MCS1(M CS1), MCS2(M CS2), MCS3(M CS3), MCS4(M CS4), MCS5(M CS5), Enumerati MCS6(M on Type CS6), MCS7(M CS7), MCS8(M CS8), MCS9(M CS9), UNFIXED (UNFIXE D)

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~70

One of the threshold s to determine whether the uplink interferen ce exists. If the uplink level is not SET Interf.of smaller UPINTER GCELLC UL Level BSC6900 than LEVLIMIT HMGAD( Threshold "Interf.of Optional) UL Level Threshold " and the uplink quality of the channel is not less than "Interf.of UL Qual. Threshold ", the

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

0~63

UPLNKM Uplink AXLENG Max TH Length

Maximum time in which a user uses the uplink SET of its BTSFALL VGCS GBFDBSC6900 BACK(Op call 510309 tional) continuou sly when the BTS works in fallback mode

Group Call Interval Reliability Type Enhancin g

10~255

Size of OML/ESL/ the EML SET OML/ESL/ UPOMLW LAPD BTSLAPD GBFDBSC6900 EML S Uplink WS(Optio 118601 Uplink Window nal) LAPD Size Window

Abis over Interval IP Type

0~96

UL PC UPPCEN Allowed

SET GCELLB BSC6900 ASICPAR A(Optiona l)

Whether to allow MS power control

GBFD110703 GBFD117601

Enhanced Power Control Algorithm Enumerati NO(No), HUAWEI on Type YES(Yes) III Power Control Algorithm

Upper class transport resource Upper group No. Class ADD It is valid UPPERG Transport RSCGRP GBFDBSC6900 only when RPID Resource (Mandator 118605 " Is First Group y) Class No. Transport Resource Group " is set to NO. The ADD Upper UPPERL Upper IPLOGIC number of BSC6900 None P logic port PORT(Op the logical number tional) port

IP QOS

Interval Type

0~2047

None

Interval Type

512~1535

If the difference between uplink receive levels of calls within the same timeslot is greater than "Offset of the difference Duration SET between UPRXLE of Uplink GCELLC uplink VLASTTI Received BSC6900 HMGAD( received ME Level Optional) levels" for Differ P seconds among N seconds, the call with weak uplink receive level within the timeslot will be handed over to another

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~16

After the existing uplink receive level, uplink receive level after the previous optimizati on, and the value of this parameter Smooth SET are UPRXLE Factor of GCELLC weightVSMOOT Uplink BSC6900 HMGAD( averaged, HPARA Received Optional) the uplink Level receive level after the optimizati on at this time is obtained and used for determing the difference between the uplink receive

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~10

If the difference between uplink receive levels of calls within the same timeslot is greater than "Offset of the Observe difference Time of SET between UPRXLE UL RX GCELLC uplink VSTATIC BSC6900 Level HMGAD( received TIME Differenc Optional) levels" for e P seconds among N seconds, the call with weak uplink receive level within the timeslot will be handed over to another

GBFD110601 GBFD510501

HUAWEI I Handover Interval HUAWEI Type II Handover

1~16

This parameter specifies whether the transmissi on of point-topoint short message s is disabled. If necessary Short SET , the UPSEND Message GCELLC GBFDBSC6900 transmissi SMDIS Uplink CAD(Opti 110203 on of the Disabled onal) uplink short message s in a specific cell can be disabled so that sufficient radio channels can be seized by normal

Point To Point Short Enumerati NO(No), Message on Type YES(Yes) Service (TS21, TS22)

Delay of releasing the nonextended uplink TBF. After receiving the last uplink RLC data block (CountVal ue=0), the network Release side SET Delay of sends the GCELLP UPTBFR Nonmessage GBFDBSC6900 RIVATEO ELDELAY extended 119203 Packet PTPARA( Uplink Uplink Optional) TBF Ack/Nack with FAI=1 to notify the MS of releasing the uplink TBF. After this parameter is set, the network side notifies the MS of

Extended Interval Uplink Type TBF

0~300

UPTHDC SDEGRA DE1

UPTHDC SDEGRA DE2

Retransmi ssion threshold when the coding mode of the uplink TBF is changed from CS2 to CS1. When the Uplink retransmi SET TBF ssion rate GCELLP Threshold BSC6900 of the SCS(Opti from CS2 uplink onal) to CS1 TBF is greater than or equal to this threshold, the coding mode of the uplink TBF is changed from CS2 Retransmi ssion threshold when the coding mode of the uplink TBF is changed from CS3 to CS2. When the Uplink retransmi SET TBF ssion rate GCELLP Threshold BSC6900 of the SCS(Opti from CS3 uplink onal) to CS2 TBF is greater than or equal to this threshold, the coding mode of the uplink TBF is changed from CS3

GBFD119106

Coding Scheme

Interval Type

0~64

GBFD118901 GBFD119106 GBFD118901 GBFD119106

CS-3/CS4 Coding Scheme Interval CS-3/CS- Type 4 Coding Scheme

0~64

UPTHDC SDEGRA DE3

UPTHDC SUPGRA DE1

Retransmi ssion threshold when the coding mode of the uplink TBF is changed from CS4 to CS3. When the Uplink retransmi SET TBF ssion rate GCELLP Threshold BSC6900 of the SCS(Opti from CS4 uplink onal) to CS3 TBF is greater than or equal to this threshold, the coding mode of the uplink TBF is changed from CS4 Retransmi ssion threshold when the coding mode of the uplink TBF is changed from CS1 to CS2. When the Uplink SET retransmi TBF GCELLP ssion rate Threshold BSC6900 SCS(Opti of the from CS1 onal) uplink to CS2 TBF is less than or equal to this threshold, the coding mode of the uplink TBF is changed from CS1

GBFD118901 GBFD119106 GBFD118901 GBFD119106

CS-3/CS4 Coding Scheme Interval CS-3/CS- Type 4 Coding Scheme

0~64

GBFD119106

Coding Scheme

Interval Type

0~64

UPTHDC SUPGRA DE2

UPTHDC SUPGRA DE3

Retransmi ssion threshold when the coding mode of the uplink TBF is changed from CS2 to CS3. When the Uplink SET retransmi TBF GCELLP ssion rate Threshold BSC6900 SCS(Opti of the from CS2 onal) uplink to CS3 TBF is less than or equal to this threshold, the coding mode of the uplink TBF is changed from CS2 Retransmi ssion threshold when the coding mode of the uplink TBF is changed from CS3 to CS4. When the Uplink SET retransmi TBF GCELLP ssion rate Threshold BSC6900 SCS(Opti of the from CS3 onal) uplink to CS4 TBF is less than or equal to this threshold, the coding mode of the uplink TBF is changed from CS3

GBFD118901 GBFD119106 GBFD118901 GBFD119106

CS-3/CS4 Coding Scheme Interval CS-3/CS- Type 4 Coding Scheme

0~64

GBFD118901 GBFD119106 GBFD118901 GBFD119106

CS-3/CS4 Coding Scheme Interval CS-3/CS- Type 4 Coding Scheme

0~64

Whether to allow cell urgent reselectio n. If this parameter is set to PERMIT and [NC2 Cell Load SET URGENT Urgent Reselecti GCELLN GBFDRESELAL Reselecti BSC6900 on Switch C2PARA( 116201 LOW on is set to Optional) Allowed Support, the load of the target cell is involved in the algorithm for NC2 cell reselectio CHK INNSPCH (Mandator y) Mode of STR querying User USERIDT CALLRES the GBFDQuery BSC6900 YPE LOP(Man informatio 111203 Type datory) n on an ADD MS GCSCHR USER(Ma ndatory) SET Support BSCPSS USFGRA USF BSC6900 OFTPAR N4BLK Granularit A(Optiona y 4 Switch l) DLD LICENSE (Mandator y) BSC6900 ULD LICENSE (Mandator y) Whether to support GBFDUSF 114101 granularit y4

NetworkFORBID( Controlled Enumerati Forbid), Cell on Type PERMIT( Reselecti Permit) on (NC2)

O&M of BSC

BYTMSI( By TMSI), BYIMSI(B y IMSI), Enumerati BYMSISD on Type N(By MSISDN), BYIMEI(B y IMEI) NOTSUP PORT(No t Enumerati Support), on Type SUPPOR T(Support )

GPRS

USR

User Name of FTP Server

User name of the FTP server

GBFD111203 MRFD210403

O&M of BSC String License Type Managem ent

None

USR

DLD RETANT CFG(Man datory) ULD BTSDEV FILE(Man datory) DLD FTPServe BSC6900 BTSPAT r User CH(Mand atory) ULD BTSLOG( Mandator y) DLD BTSSW( Mandator

User name for the FTP server. When the FTPServe r.exe file download GBFDed 111202 through the LMT is installed, the user name is admin.

O&M of BTS

String Type

None

Start time when the TRX Energy SET energy Saving USTBGN BTSDOM saving GBFDStart BSC6900 TIME UBP(Man function is 111202 Time[HH: datory) enabled MM] for the BTS3002 E. End time when the TRX Energy SET energy Saving USTEND BTSDOM saving GBFDEnd BSC6900 TIME UBP(Man function is 111202 Time[HH: datory) enabled MM] for the BTS3002 E.

O&M of BTS

Compoun HOUR, d Type MINUTE

O&M of BTS

Compoun HOUR, d Type MINUTE

Upper temperatu re threshold for the environm ent alarm box to report an alarm indicating that the ambient temperatu re is too Upper high. If SET UTEMTH Temperat GBFDthe BSC6900 BTSEXD( D ure ambient 111202 Optional) Threshold temperatu re of the BTS is higher than this threshold, the environm ent alarm box reports the alarm. In multimode scenario, the value

O&M of BTS

Interval Type

-99~99

When a UL subcellOL subcel handover decision is performe d to a call, the BSC determine s whether the number of handover SET failures UTOOFAI MaxRetry GCELLH reaches GBFDLMAXTIM Time after BSC6900 OIUO(Opt the 113201 E UtoO Fail ional) "MaxRetry Time after UtoO Fail". If the number reaches the threshold, the UL subcell to OL subcell handover is prohibited After an MS performs a OL subcell to UL subcell handover SET Penalty successfu UTOOHO GCELLH GBFDTime of BSC6900 lly, the PENTIME OIUO(Opt 113201 UtoO HO MS ional) cannot be handed over to the OL subcell again within the value of

Concentri Interval c Cell Type

0~8

Concentri Interval c Cell Type

0~255

One of the parameter s that determine the coverage of the OL subcell and of the UL subcell. "UtoO HO Received Level UtoO HO SET Threshold UTOORE Received GCELLH ", "OtoU GBFDBSC6900 CTH Level OIUO(Opt HO 113201 Threshold ional) Received Level Threshold ", "Receive QualThrs hAMRFR" , "TA Threshold ", and "TA Hysteresi s" determine the coverage of the OL

Concentri Interval c Cell Type

0~63

When this parameter is set to YES, the existing call is performe d in the OL subcell, and "OL to UL HO Allowed" is set to YES, an SET OL UTOOTR UtoO GCELLH subcell to GBFDAFHOALL Traffic HO BSC6900 OIUO(Opt UL 113201 OW Allowed ional) subcell handover is triggered if the traffic volume in the UL subcell is smaller than "En Iuo Out Cell Low Load Thred". If the

Concentri Enumerati NO(No), c Cell on Type YES(Yes)

Hierarchic al handover period of the load handover from the UL subcell to the OL subcell. If the channel seizure ratio of SET the UL UTRAFH Underlay GCELLH subcell is GBFDOPERIO HO Step BSC6900 OIUO(Opt greater 113201 D Period ional) than the UL subcell general overload threshold, all the calls in the cell send handover requests at the same time and the load

Concentri Interval c Cell Type

1~255

Hierarchic al level step of SET the load Underlay UTRAFH GCELLH handover GBFDHO Step BSC6900 OSTEP OIUO(Opt from the 113201 Level ional) UL subcell to the OL subcell

Concentri Interval c Cell Type

1~63

This parameter specifies the type of a 3G cell. A cell ADD type can UTRANC Utran Cell GEXT3G be BSC6900 ELLTYPE Type CELL(Ma Frequenc ndatory) y Division Duplex (FDD) or Time Division Duplex (TDD). ADD BTSRET BSC6900 ANT(Man datory) Vendor code of the RET antenna

GBFD114301 GBFD114302

GSM/WC DMA Interopera FDD(FDD bility Enumerati ), GSM/TD- on Type TDD(TDD SCDMA ) Interopera bility

VENDOR Vendor CODE Code

GBFD111202

O&M of BTS

String Type

None

This parameter is used to limit the maximum number of channels that can be used by the VGCS in a cell. This prevents too many Maximum SET channels Number VGCSMA GCELLG in the cell of BSC6900 XNUM SMR(Opti from Channels onal) being for VGCS occupied by the VGCS and thus prevents public network services from being affected. When this parameter is set to 255, the

GBFD510301 GBFD510302

Public Voice Group Call Interval Service Type Public Voice Broadcast Service

0~190,25 5

This parameter specifies whether the preemptio n of channels Channel SET between VGCSPR Allocation GCELLG public BSC6900 EEMPT Strategy SMR(Opti network for VGCS onal) services and the VGCS is allowed when preemptio n conditions are met.

GBFD510301 GBFD510302

No_Priorit y(No Priority),P ublic_Net work_Firs Public t(Public Voice Network Group First),VG Call CS_First( Enumerati Service No on Type Public Priority),P Voice ublic_Net Broadcast work_Firs Service t(Public Network First),VG CS_First( VGCS First)

This parameter is used to reserve a certain number of channels in a cell for the Voice Reserved SET Group Number VGCSRS GCELLG Call of BSC6900 RVNUM SMR(Opti Service Channels onal) (VGCS) for VGCS to use directly. The specified channels are unavailabl e to public network services.

GBFD510301 GBFD510302

Public Voice Group Call Interval Service Type Public Voice Broadcast Service

0~190

This parameter specifies the usage threshold of the CPU for VIP user calls that can be admitted. When the usage of a CPU is greater SET than this VIPACCE VIP BSCFCP threshold, SSCPUR Access BSC6900 ARA(Opti the new ATE CPU Rate onal) service requests from VIP users are transferre d to another CPU for processin g. When the usage of all CPUs is greater than this threshold, Is VIP Cell.The parameter ADD is used VIPCELL VIP Cell BSC6900 GCELL(O for ptional) BSC6900 flow control.

GBFD111705

GSM Flow Control

Interval Type

50~95

GBFD111705

GSM Flow Control

Enumerati NO(No), on Type YES(Yes)

VIPPRIO VIP RITY Priority

SET BSCFCP BSC6900 ARA(Opti onal)

SET VIPSHAR VIP Share BSCFCP EINCPUR in CPU BSC6900 ARA(Opti ATE Rate onal)

This parameter specifies the eMLPP priority value correspon ding to the VIP call. When the eMLPP(E nhanced MultiLevel Preceden ce and Preemption service) priority value of a user is greater than or equal to the value of this This parameter specifies the usage threshold of the CPU for VIP user calls that are transferre d from other CPUs. When the usage of a CPU is greater than this threshold, the VIP service requests transferre d from other CPUs are

GBFD111705

GSM Flow Control

NONE(No ne), LEVEL4( User Level 4), LEVEL3( User Level 3), LEVEL2( User Level 2), Enumerati LEVEL1( on Type User Level 1), LEVEL0( User Level 0), LEVELB( User Level B), LEVELA( User Level A)

GBFD111705

GSM Flow Control

Interval Type

50~95

VLANFlA VLANID G Flag

If the parameter is set to Disable, the added IP path is not configure ADD d with the GBFDBSC6900 IPPATH( VLAN ID. 118605 Optional) If the parameter is set to Enable, the added IP path is configure d with the VLAN ID. Specified Vlan None enabling flag

IP QOS

DISABLE( Enumerati Disable), on Type ENABLE( Enable)

SET VLANFLA BSCABIS Vlan Flag BSC6900 G PRIMAP( Optional) VLANID Flag of VLANFLA First G1 Local IP address

None

Enumerati DISABLE, on Type ENABLE

VLANID ADD flag of SCTPLN BSC6900 first local None K(Optiona IP l) address

None

DISABLE( DISABLE) Enumerati , on Type ENABLE( ENABLE)

VLANID Flag of VLANFlA Second G2 Local IP address

VLANID ADD Flag of SCTPLN BSC6900 second K(Optiona Local IP l) address

None

None

DISABLE( DISABLE) Enumerati , on Type ENABLE( ENABLE)

VLANID

ADD IPPATH( Mandator y) VLAN ID. BSC6900 ADD VLANID( Mandator y)

VLANID of the IP address of the specified next hop

GBFD118611 GBFD118622

Abis IP over Interval E1/T1 Type A IP over E1/T1

2~4094

VLANID

VLAN ID

ADD VLAN of ETHMA( GBFDBSC6900 the MA in Mandator 118630 the MD y)

Ethernet OAM

Interval Type

2~4094

VLANID

VLAN ID

SET BTSVLAN (Optional) BSC6900 IMP BTSVLAN (Optional)

VLAN ID of the service type

GBFD118601

Abis over Interval IP Type

2~4094

VLANID

VLAN ID

VLAN to which the maintena ADD nce BTSETH associatio BSC6900 MA(Mand n belongs atory) in the maintena nce domain.

GBFD118630 MRFD210301

Ethernet OAM Configura Interval tion Type Managem ent

2~4094

VLAN ID of First VLANID1 Local IP address

ADD SCTPLN BSC6900 K(Mandat ory)

VLAN ID of first Local IP address

None

None

Interval Type

2~4094

VLAN ID ADD VLAN ID of Second SCTPLN of second VLANID2 BSC6900 None Local IP K(Mandat Local IP address ory) address

None

Interval Type

2~4094

VLAN VLANPRI Priority

SET DSCPMA VLAN BSC6900 P(Optiona priority l)

None

None

Interval Type

0~7

VLANPRI

VLAN Priority

SET BTSVLAN (Optional) BSC6900 IMP BTSVLAN (Optional)

VLAN priority level of the service type. This parameter helps to determine the packet service priority level at the data link layer GBFDon the Ethernet. 118601 If this parameter is set to 0, the service type has the highest VLAN priority level. If this parameter is set to 7, the service VLAN switch for GBFDthe 118601 service type

Abis over Interval IP Type

0~7

VLANSWI VLAN TCH Switch

SET BTSVLAN (Optional) BSC6900 IMP BTSVLAN (Optional)

Abis over Enumerati NO(N0), IP on Type YES(Yes)

VOICEVE Speech R Version

SET GCELLC BSC6900 CACCES S(Optiona l)

Speech version MRFDsupported 210301 by a cell

Configura tion Bit Field Managem Type ent

FULL_RA TE_VER1 , FULL_RA TE_VER2 , FULL_RA TE_VER3 , HALF_RA TE_VER1 , HALF_RA TE_VER2 ,

Enable Alarm ADD VOL24_M Reporting BSC6900 EMU(Opti ASK for 24V onal) Power

24V voltage alarm switch

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

Upper Limit of ADD VOL24_T Alarm for BSC6900 EMU(Opti HD_HIGH 24V onal) Power

Upper limit for triggering MRFDa 24 V 210304 voltage sensor alarm Lower limit for triggering MRFDa 24 V 210304 voltage sensor alarm 48V voltage alarm switch

Faulty String Managem Type ent

None

Lower Limit of ADD VOL24_T Alarm for BSC6900 EMU(Opti HD_LOW 24V onal) Power

Faulty String Managem Type ent

None

Enable Alarm ADD VOL48_M Reporting BSC6900 EMU(Opti ASK for 48V onal) Power

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

Upper Limit of ADD VOL48_T Alarm for BSC6900 EMU(Opti HD_HIGH 48V onal) Power

Upper limit for triggering MRFDa 48V 210304 voltage sensor alarm

Faulty String Managem Type ent

None

Lower Limit of ADD VOL48_T Alarm for BSC6900 EMU(Opti HD_LOW 48V onal) Power

Standing Wave VSWREN Alarm ABLED CFG Enabled

Lower limit for triggering a 48V voltage sensor alarm Whether to enable SET the BTSDFC standing BSC6900 UBP(Opti wave onal) alarm parameter s to be

MRFD210304

Faulty String Managem Type ent

None

MRFD210304

Faulty NO(NO), Enumerati Managem YES(YES on Type ent )

VSWRER RTHRES

VSWRFIL ETERCO UNTER

VSWRTH RES1

This parameter specifies a condition for generatin g a BTS alarm. This VSWR SET parameter TRX GCELLO together GBFDUnadjuste BSC6900 THEXT(O with 111202 d ptional) "VSWR Threshold TRX error threshold" is used to detect whether the antenna system connecte d to the SET BTSDFC Filtering Serious UBP(Opti times of VSW onal) serious MRFDAlarm BSC6900 SET standing 210304 Filter BTSDDP wave Times UBP(Opti alarms onal) Standing wave alarm threshold. SET When the BTSDFC VSWR is Standing UBP(Opti greater Wave onal) than the MRFDRadio BSC6900 SET value of 210304 Alarm BTSDDP this Threshold UBP(Opti parameter onal) , the TRX reports a standing wave alarm.

O&M of BTS

Interval Type

0~12

Faulty Interval Managem Type ent

1~30

14(1.4), 15(1.5), 16(1.6), 18(1.8), 20(2.0), Faulty 22(2.2), Enumerati Managem 24(2.4), on Type ent 26(2.6), 28(2.8), 30(3.0), 33(3.3), 36(3.6), 88(8.8)

SET BTSDFC Serious UBP(Opti VSWRTH VSW onal) BSC6900 RES2 Alarm SET Threshold BTSDDP UBP(Opti onal)

SET VSWRUN VSWR GCELLO JUSTTHR TRX Error BSC6900 THEXT(O ES Threshold ptional)

Serious standing wave alarm threshold. When the VSWR is greater than the value of this parameter , the TRX reports a serious standing wave alarm. This parameter specifies a condition for generatin g a BTS alarm. This parameter together with "VSWR TRX unadjuste d threshold" are used to check whether the antenna system connectin g to the TRX is faulty. If the value of this parameter

MRFD210304

18(1.8), 20(2.0), 22(2.2), 24(2.4), 26(2.6), Faulty 28(2.8), Enumerati Managem 30(3.0), on Type ent 32(3.2), 35(3.5), 38(3.8), 41(4.1), 45(4.5), 88(8.8)

GBFD111202

O&M of BTS

Interval Type

0~12

VVer

SET BTSAUT V-Version BSC6900 ODLDAC No. TINFO(M andatory)

V-version number of GBFDthe BTS 111202 software

O&M of BTS

Interval Type

0~999

This timer is used to set the time of waiting for a ReleaseIn dication SET message WAITFO GCELLT after a T3109 BSC6900 RRELIND MR(Optio ChannelR nal) elease message is sent. If the timer expires, the channel is deactivate d. When the BSC6900 sends a ChannelR elease message and the current call uses the AMRFR encoding mode, the timer T3109 Wait for SET (AMRFR) WAITFO REL GCELLT is started. RRELIND BSC6900 Indication MR(Optio If the AMRFR AMR FR nal) BSC6900 receives the ReleaseIn dication message before the T3109 (AMRFR) timer expires, the timer T3109 (AMRFR) is stopped.

GBFD110501

Call Control

Interval Type

4000~330 00

GBFD115501

AMR FR

Interval Type

3000~340 00

When the BSC sends a ChannelR elease message and the current call uses the AMRHR encoding mode, the timer T3109 SET (AMRHR) WAITFO T3109 for GCELLT is started. GBFDRRELIND BSC6900 AMR HR MR(Optio If the BSC 115502 AMRHR nal) receives the ReleaseIn dication message before the T3109 (AMRHR) timer expires, the timer T3109 (AMRHR) is stopped. If the Timer of waiting for the MS's response to the location measure ment request sent from the BSC. Timer of ADD If the BSC WaitMSL MS GEXTSM does not ocationRe Location BSC6900 None LC(Option receive sponse Response al) the from MS measure ment informatio n reported by the MS before the timer expires, then the MS location

AMR HR

Interval Type

3000~340 00

None

Interval Type

0~1000

The TCHs reserved for the emergenc y call are assigned to the user during the service assignme WAITRE Timer of SET nt. If the SVCHAN Reserved GCELLT TCHs are BSC6900 REFRES TCH for MR(Optio not HTIMER EMC nal) assigned to the emergenc y call within a period, the TCHs are released from the reservatio n queue.

GBFD110202 GBFD110521

Emergenc y Call Service (TS12) Interval Guarante Type ed Emergenc y Call

1~30

When the dynamic PDCH needs to use MAIO of the SDCCH, the SDCCH is not allowed to be assigned to new calls IBCA SET within the WAITSD Wait GCELLC value of GBFDCCHIDLE BSC6900 SDCCH HMGAD( the 117002 TIMER Idle Timer Optional) parameter . After the timer expires, check whether the SDCCH is idle. If the SDCCH is idle, MAIO of the SDCCH is allowed to be

IBCA (Interfere nce Interval Based Type Channel Allocation )

0~60

Timer of MS ADD WaitSML Location GEXTSM CLocation BSC6900 Response LC(Option Response from al) SMLC

SET Heating WARMSE BTSOUT Equipmen BSC6900 T PUT(Opti t onal)

Timer of waiting for the SMLC's response to the MS location request sent from the MSC. If the SMLC does not send any response to the MS location None request before the timer expires, then the MS location fails. In this case, the BSC sends a Perform Location Abort message to the SMLC for Whether to start the heating equipmen t of the BTS. In multimode scenario, the value GBFDof this 111202 parameter in one mode must be the same as the value of the correspon ding parameter

None

Interval Type

0~1000

O&M of BTS

INACTIV E(Inactive Enumerati ), on Type ACTIVE( Active)

Enable ADD WATER_ Water BSC6900 EMU(Opti MASK Alarm onal) Reporting

Water sensor alarm switch

MRFD210304

CLOSE(C Faulty Enumerati lose), Managem on Type OPEN(Op ent en)

WEEK

Week Limit

Whether to limit the operation weekday of the operator. ADD If the BSC6900 OP(Optio weekday nal) needs to be limited, see the descriptio n of "Week". This parameter is used to select the location of a cell, east or west longitude. Whether to start the humidifica tion equipmen t of the BTS. In multimode scenario, the value of this parameter in one mode must be the same as the value of the correspon ding parameter

GBFD111203 MRFD210305

O&M of NOLIMIT( BSC Enumerati No Limit), Security on Type LIMIT(Lim Managem it) ent

SET WELONG WE GCELLLC BSC6900 I Longitude S(Optiona l)

GBFD115402 GBFD118201

East_Lon BSSgitude(Ea Based st LCS (Cell Longitude ID + TA) Enumerati ), Softon Type West_Lon Synchroni gitude(W zed est Network Longitude

Humidific SET ation BTSOUT WETSET BSC6900 Equipmen PUT(Opti t onal)

GBFD111202

O&M of BTS

INACTIV E(Inactive Enumerati ), on Type ACTIVE( Active)

Whether to trigger an active/sta ndby port switchove r. If this parameter is set to YES, an active/sta ndby port switchove r is triggered Whether when a WHETHE STR affect the fault is GBFDRAFFEC BSC6900 IPCHK(O port detected 118609 TSWAP ptional) swapping on the active port. If this parameter is set to NO, an active/sta ndby port switchove r is not triggered when a fault is detected on the

IP Fault NO(NO), Detection Enumerati YES(YES Based on on Type ) BFD

LAPD WINADJS Window WITCH Adjust Switch

Whether to start the dynamic adjustme nt of the LAPD window. If this parameter is set to ALLOW, the LAPD transmit and SET receive OTHSOF window is GBFDBSC6900 TPARA(O enlarged 118601 ptional) when the delay is increased , which improves the transmissi on efficiency of LAPD but consumin g more buffer resources in the

DENY(De Abis over Enumerati ny), IP on Type ALLOW(A llow)

WK

Week

You can ADD select BSC6900 OP(Mand multiple atory) weekdays .

GBFD111203 MRFD210305

SUN(Sun day), MON(Mo nday), TUE(Tues O&M of day), BSC Enumerati WED(We Security on Type dnesday), Managem THU(Thur ent sday), FRI(Frida y), SAT(Satu rday)

Working mode of the M3UA link set, including M3UA_A ADD SP and WKMOD Work BSC6900 M3LKS(O M3UA_IP E mode ptional) SP. For details about the ASP and IPSP, see the RFC4666. Time when the BTS stops checking for a radio link alarm. If this time SET is up, the End Time WLAETIM GTRXRL BTS of WLA BSC6900 E ALM(Opti stops Detection onal) checking for or reporting a radio link alarm until the next alarm detection

GBFD118602

M3UA_A SP(M3UA Enumerati _ASP), A over IP on Type M3UA_IP SP(M3UA _IPSP)

GBFD111202

O&M of BTS

Interval Type

0~24

Wireless Link WLAFLA Alarm G Critical Permit

Whether to enable the BTS to report a major radio link alarm. If this parameter is set to YES, the BTS reports a SET major GTRXRL radio link GBFDBSC6900 ALM(Opti alarm 111202 onal) when a radio link warning is not cleared within "WLARP". If this parameter is set to NO, the BTS does not report any major

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

WLARP

WLA SET Prompting GTRXRL BSC6900 Recover ALM(Opti Period onal)

Begin SET WLASTIM Time of GTRXRL BSC6900 E WLA ALM(Opti Detection onal)

Period for clearing a radio link warning. If a radio link warning is cleared within this period, the BTS reports the recovery alarm for the warning. If a radio link warning is not cleared within this period, the BTS determine s whether to report a major radio link alarm Time when the BTS starts to check for a radio link alarm. If this time is up, the BTS starts to check for and report a radio link alarm.

GBFD111202

O&M of BTS

Interval Type

1~255

GBFD111202

O&M of BTS

Interval Type

0~24

Wireless WLNKAL Link MFLAG Alarm Flag

Whether to enable the BSC to deliver radio link alarm parameter s to the BTS. If this parameter is set to YES, the SET BSC GTRXRL delivers GBFDBSC6900 ALM(Man the radio 111202 datory) link alarm parameter s to the BTS. If this parameter is set to NO, the BSC does not deliver the radio link alarm parameter

O&M of BTS

Enumerati NO(No), on Type YES(Yes)

Flag of FMT WORKAR Work the work MRFDBSC6900 DATA(Op EA Area Flag area to be 210301 tional) formatted

SET WORKIN Working BTSRXU GSTAND BSC6900 Standard BP(Optio ARD nal)

Working mode of the RXU board

GBFD111202

Active(For mat active Configura area), tion Enumerati Standby( Managem on Type Format ent standby area) GSM_AN D_UMTS( GSM AND O&M of Enumerati UMTS), BTS on Type UMTS(U MTS), GSM(GS M) Configura tion Enumerati GO(GSM Managem on Type Only) ent

WORKM Work ODE Mode

ADD Work SUBRAC BSC6900 mode of K(Mandat subrack ory)

MRFD210301

WORKM Work ODE Mode

Working mode. E1: The E1 system is recomme nded by the IUT-T. E1 carries signals at 2.048 Mbit/s. G.703 defines the electrical specificati SET on and BSC6900 E1T1(Opti None G.704 onal) defines the frame format for E1 telecomm unication lines. The E1 system is used in Europe and China. T1: The T1 system is

None

E1_UNBA (E1 Unbalanc e), Enumerati E1_BA(E on Type 1 Balance), T1(T1), E1(E1)

BTS port working mode. This parameter must be consistent with that of the peer. Work mode of a BTS. A BTS can work in the ADD WORKM Work following GBFDBSC6900 BTS(Opti ODE Mode 111202 modes: onal) E1: The E1 system is recomme nded by the ITU-T. E1 carries signals at 2.048 Mbit/s. G.703 defines the electrical specificati on and ADD ATERSL( Window Optional) size of the Window GBFDWS BSC6900 ADD Ater Size 111203 ATERCO signaling NSL(Opti link onal) Time for which the BTS waits to swap the OML after the OML is Wait Time SET interrupte before BTSOML d. With GBFDWTBS BSC6900 OML BACKUP( this 113728 Switch Optional) parameter , the BTS does not swap the OML when the OML is interrupte

O&M of BTS

Enumerati E1(E1), on Type T1(T1)

O&M of BSC

Interval Type

1~127

OML Backup

Interval Type

30~300

WTBS

Waiting time before establishi ng a link Ring I SET in the Wait Time BTSRING GBFDBSC6900 reverse Before ATTR(Opt 117801 direction Switch ional) after the transmissi on of a BTS is disrupted

Ring Interval Topology Type

60~300

WTRT

SET Wait to WTR BSC6900 MSP(Opti restore Time[Sec] onal) time

GBFD111701

Board Interval Switchove Type r

30~60000

ZONET

SET Time TimeZone BSC6900 TZ(Option zone al)

GBFD116101 MRFD210301

GMT1200(GM T-12:00), GMT1100(GM T-11:00), GMT1000(GM T-10:00), GMT0930(GM T-09:30), GMTSupport 0900(GM of T-09:00), Daylight GMTSaving Enumerati 0800(GM Time on Type T-08:00), Configura GMTtion 0700(GM Managem T-07:00), ent GMT0600(GM T-06:00), GMT0500(GM T-05:00), GMT0430(GM T-04:30), GMT0400(GM T-04:00), GMT-

Actual Value Range

Unit

Default Value

Recommend Impact ed Value

Paramete r Access Relations hip

Service Interrupt Interrupti ed After on Scope Modificat ion

0~70

None

50

50

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

50

50

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~8, step:0.1

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TRUE, FALSE

None

FALSE

FALSE

BTS

None

Read & Write

BTS

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~255

30

30

BSC

The value of this parameter should be Read & smaller Write than "AbisFCTi mer2".

N (No impact on Not the UE in involved idle mode)

10~255

60

60

BSC

The value of this parameter should be Read & greater Write than "AbisFCTi mer1".

N (No impact on Not the UE in involved idle mode)

IDLETSA LLOC_0, IDLETSA LLOC_1, None IDLETSA LLOC_2, IDLETSA LLOC_3

IDLETSALL OC_0

IDLETSALL OC_0

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

90

90

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3600

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

GSM_PH ASE_1, GSM_PH ASE_2, None GSM_PH ASE_2Plu s

It is recommende d that the value of this GSM_PHAS parameter is BSC E_2 the same as that for "A Interface Tag".

The value of this parameter is the same as those of Read & "Um Write Interface Tag" and "A Interface Tag".

N (No impact on Not the UE in involved idle mode)

1~255

None

40

40

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~250

None

100

100

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

8BIT, 11BIT

None

8BIT

8BIT

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OSubcell, USubcell, None NoPrefer

Usubcell

Usubcell

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ULPRIOR ITY, NEUTRA None L, DLPRIOR ITY

NEUTRAL

NEUTRAL

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~9

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

15~7200

120

120

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Disable, Enable

None

Enable

Enable

PPP link

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

PPP link

CLOSE, OPEN

None

CLOSE

CLOSE

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

COMPUL 0, None COMPUL 1, FLEX

FLEX

FLEX

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

4_75KBIT /S, 5_15KBIT /S, 5_90KBIT /S, 6_70KBIT /S, None 7_40KBIT /S, 7_95KBIT /S, 10_2KBIT /S, 12_2KBIT /S

4_75KBIT/S1&5_15KBIT/ S0&5_90KBIT/ S1&6_70KBIT/ S0&7_40KBIT/ S1&7_95KBIT/ S0&10_2KBIT/ S0&12_2KBIT/ S-1

4_75KBIT/S1&5_15KBIT/ S0&5_90KBIT/ S1&6_70KBIT/ S0&7_40KBIT/ Cell S1&7_95KBIT/ S0&10_2KBIT/ S0&12_2KBIT/ S-1

None

Read & Write

N (No impact on Not the UE in involved idle mode)

4_75KBIT /S, 5_15KBIT /S, 5_90KBIT /S, None 6_70KBIT /S, 7_40KBIT /S, 7_95KBIT /S

4_75KBIT/S1&5_15KBIT/ S0&5_90KBIT/ S1&6_70KBIT/ S0&7_40KBIT/ S1&7_95KBIT/ S-0

4_75KBIT/S1&5_15KBIT/ S0&5_90KBIT/ S1&6_70KBIT/ Cell S0&7_40KBIT/ S1&7_95KBIT/ S-0

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

6_60KBIT/S1&8_85KBIT/ S1&12_65KBI T/S-1

6_60KBIT/S1&8_85KBIT/ SCell 1&12_65KBI T/S-1

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

min

10

10

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

60~300

180

180

BTS

The value of this parameter must be smaller Read & than "AC Write Voltage Upper Threshold ".

N (No impact on Not the UE in involved idle mode)

61.0~300. 0 (step: V 0.1)

2800

2800

BTS

The value of this parameter must be Read & greater than "AC Write undervolt age alarm threshold" . The value of this parameter must be Read & smaller than "AC Write overvolta ge alarm threshold" .

N (No impact on Not the UE in involved idle mode)

60.0~299. 0 (step: V 0.1)

1800

1800

BTS

N (No impact on Not the UE in involved idle mode)

60~300

280

280

BTS

The value of this parameter must be greater Read & than "AC Write Voltage Lower Threshold ".

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~50

ms

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~768

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PORT0_ CDEF, PORT1_ CDEF

None

None

BTS

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

1~167772 None 15

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYMANU AL, None BYAUTO

BYAUTO

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 1, 2

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

COMMO N_DLD, QUICK_D None LD1, QUICK_D LD2

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Lock, Unlock, None Shutdown

UNLOCK

UNLOCK

Cell

None

Read & Write

N (No impact on the UE in Cell idle mode)

Lock, Unlock, None Shutdown

Unlock

Unlock

TRX

None

Read & Write

If the value of this parameter is modified to "Lock", forced handover is triggered to hand the ongoing services on the correspon TRX ding TRX to another TRX. Services will be disrupted if the handover fails. If the value of this parameter is modified to "Shutdow n", the

Lock, Unlock, None Shutdown

Unlock

Unlock

Current BFD session

None

Read & Write

If the value of this parameter is modified to "Lock", forced handover is triggered to hand the ongoing services on the correspon Channel ding channel to another channel. Services will be disrupted if the handover fails. If the value of this parameter is modified to "Shutdow N (No impact on Not the UE in involved idle mode)

hour{0~2 3} None min{0~59}

None

None

BSC6900 None

Read & Write

0~100

None

10

10

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

hour{0~2 3} None min{0~59}

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

RATIORU None LE

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~51 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~51 character None s

None

None

BTS

This parameter can be configure d only when Read & "BTS Write Software Version 1" is configure d.

N (No impact on Not the UE in involved idle mode)

0~600

ms

400

400

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~60

dB

20

20

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-60~-35, 0

dBm

-50

-50

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

ms

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

dB

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~100

None

20

20

Board

If the number of echo cancellati ons performe d by AEC exceeds "AEC Detect Read & Threshold Write " within the time specified by "AEC Detect Time", the TFO is closed forcibly.

N (No impact on Not the UE in involved idle mode)

1~10

Board

If the number of echo cancellati ons performe d by AEC exceeds "AEC Detect Read & Threshold Write " within the time specified by "AEC Detect Time", the TFO is closed forcibly.

N (No impact on Not the UE in involved idle mode)

1920~307 20, ms step:480

64_Times

64_Times

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~30240, ms step:480

48

48

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65534

None

None

None

None

None

Read & Write

Not involved

Not involved

BSC

None

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1920~307 20, ms step:480

52_Times

52_Times

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~30240, ms step:480

32

32

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

65334~65 None 383

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

65033~65 None 533

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~1024 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ALL, ONEBYO None NE

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

ALL, ONEBYO None NE

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ABIS, A

None

ABIS

ABIS

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, R3, R2, None R2ANDR 3

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-12~12

dB

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-23~-4

dBm

-18

-18

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

3~12

dB

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-23~-4

dBm

-4

-4

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-23~-4

dBm

-23

-23

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FIXEDLE VEL, ADAPTIV None E, FIXEDGA IN

FIXEDGAIN

FIXEDGAIN

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~400000 kbit/s 0

None

None

When "BWMOD E" in "ADD RSCGRP " is set to HALF_DU PLEX, this parameter is valid;if the "BWMOD E" in "ADD Transmis RSCGRP sion " of upper Read & resource class and Write group lower class RSCGRP is set to HALF_DU PLEX, the "AllBw" in "ADD RSCGRP " of upper class RSCGRP can not less than the "AllBwE"

N (No impact on Not the UE in involved idle mode)

NOTALL OW, ALLOW

None

ALLOW

ALLOW

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

100

100

Cell

The following condition must be met: "ALLOWA MRHALF Read & RATEUS Write ERPERC" <= "ALLOW HALFRAT EUSERP ERC".

N (No impact on Not the UE in involved idle mode)

NOTALL OW, ALLOW

None

NOTALLOW NOTALLOW BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~16

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

100

100

Cell

The following condition must be met: "ALLOW HALFRAT Read & EUSERP Write ERC" >= "ALLOWA MRHALF RATEUS ERPERC" .

N (No impact on Not the UE in involved idle mode)

ALLCIC, None ALLNULL

None

ALLCIC

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

ALLCIC, None ALLNULL

ALLCIC

ALLCIC

PBE1T1

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

30

30

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

30

30

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

30

30

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

30

30

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

30

30

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

30

30

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65534

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

mA

10

10

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

45~155

mA

100

100

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

125~175

mA

150

150

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

BTS

The recomme nded value of this parameter is greater than twice "Alarm Clear Read & Accumula Write tive Time Threshold " and greater than twice "Flash Alarm Occur Threshold ".

N (No impact on Not the UE in involved idle mode)

0~100

per cent

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~250

None

BTS

The recomme nded value of this parameter Read & is greater Write than twice "Alarm Clear Times Threshold ".

N (No impact on Not the UE in involved idle mode)

0~250

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

flt, evt, all None

all

all

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 1, 2, 3, 4, 5, 6, 7, None 8, 9, 10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~0.9, step:0.1

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~100 m 00

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~6553

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

3281~328 feet 10

None

None

BSC6900 None

Read & Write

Not involved

Not involved

Critical, Major, Minor, Warning

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

Critical, Major, Minor, Warning

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE D, None ENABLE D

DISABLED

DISABLED

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE D, None ENABLE D

DISABLED

DISABLED

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE D, None ENABLE D

DISABLED

DISABLED

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE D, None ENABLE D

DISABLED

DISABLED

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE D, None ENABLE D

DISABLED

DISABLED

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE D, None ENABLE D

DISABLED

DISABLED

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~32, step:2

dB

16

16

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~3

None

Cell

This parameter is valid when "PWRCT RLSW" in the "SET GCELLP WRBASI C" command Read & is set to Write PWR2 and "DNPCEN " in the "SET GCELLB ASICPAR A" command is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "AMRDL QLTHRE D" >= "AMRDL QHTHRE D".

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "AMRDL QLTHRE D" >= "AMRDL QHTHRE D".

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~63

dB

33

33

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "AMRDLS SHTHRE D" >= "AMRDLS SLTHRE D".

N (No impact on Not the UE in involved idle mode)

0~63

dB

25

25

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "AMRDLS SHTHRE D" >= "AMRDLS SLTHRE D".

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0~255

dB

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

dB

20

20

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

dB

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

dB

100

100

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

75

75

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

dB

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

dB

108

108

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

15

15

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "AMRFUL LTOHALF HOALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~32

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~30

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~30

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~30

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~32

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

480~7200 ms , step:480

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~4

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~99

per cent

55

55

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~3

None

Cell

This parameter is valid when "PWRCT RLSW" in the "SET GCELLP WRBASI C" command Read & is set to Write PWR2 and "DNPCEN " in the "SET GCELLB ASICPAR A" command is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "AMRUL QLOWTH RED" >= "AMRUL QHTHRE D".

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "AMRUL QLOWTH RED" >= "AMRUL QHTHRE D".

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "AMRULS SHTHRE D" >= "AMRULS SLTHRE D".

N (No impact on Not the UE in involved idle mode)

0~63

dB

18

18

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "AMRULS SHTHRE D" >= "AMRULS SLTHRE D".

N (No impact on Not the UE in involved idle mode)

0~65535

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

3~30

dB

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~30

dB

12

12

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~5 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~4599

None

None

None

None

None

Read & Write

Not involved

Not involved

0~4599

None

None

None

IP path

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~100 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

MODE0, MODE1, MODE2

None

MODE0

MODE0

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-32~0

dB

-13

-13

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-64~0

dB

-48

-48

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~360

degree

360

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SENDPO WER, None NOPOW ER

NOPOWER

NOPOWER

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~35

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

A, B

None

None

None

TRX

None

Read & Write

Not involved

Not involved

A, B

None

None

None

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

A, B, NULL

None

NULL

NULL

BTS

The setting of this Read & parameter Write depends on "Board Type".

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

MTP3 link None

Read & Write

Not involved

Not involved

M3UA, BBAP

None

None

None

SCTP link None

Read & Write

Not involved

Not involved

MTP2, OTHER, None TCSTM1

None

None

BSC

None

Read & Write

Not involved

Not involved

1~65535

packet

20

20

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

bit

1024

1024

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

bit

256

256

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

packet

20

20

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

packet

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

packet

20

20

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

bit

384

384

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PRIMARY , None STANDB Y, ALL

PRIMARY

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PRIMARY , None STANDB Y

PRIMARY

PRIMARY

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~80

per cent

50

50

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

5~126

None

100

100

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

5~100

per cent

100

100

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

3~10

None

Ethernet port

None

Read & Write

Ethernet port

3~10

ms

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

MTP3 link None

Read & Write

Not involved

Not involved

0~27

None

None

None

ATERCO None NSL

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

MTP3 link None

Read & Write

Not involved

Not involved

power, env, sig, trunk, hardware, software, None run, comm, service, handle

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

power, env, sig, trunk, hardware, software, None run, comm, service, handle

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

DISABLE

DISABLE

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~61

dB

35

35

Cell

In an enhanced concentric cell, if "LOWRX LEVOLF ORBIDS WITCH" is set to ON, this parameter and "OTOUR ECEIVET H" determine whether Read & Write the current uplink receive level meets the condition for assigning channels of the overlaid subcell during the assignme nt of the underlaid

N (No impact on Not the UE in involved idle mode)

0~62, 255 None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23, 255 None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

500~6000 ms 0

10000

10000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~300

30

30

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~300

60

60

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~300

30

30

BSC

This parameter is used with "T18 s" in flow control over the A Read & interface. Write The value of this parameter should be smaller than "T18 s".

N (No impact on Not the UE in involved idle mode)

1~300

60

60

MSC

This parameter is used with "T17 s" in flow control over the A Read & interface. Write The value of this parameter should be greater than "T17 s".

N (No impact on Not the UE in involved idle mode)

1~300

30

30

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~300

30

30

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~300

20

20

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when Read & "IUOTP" Write is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

This parameter is valid only when "ATCBHo Switch" is set to OPEN, Read & "IUOTP" Write is set to EDB_cell, or "TIGHTB CCHSWI TCH" is set to ON.

N (No impact on Not the UE in involved idle mode)

0~63

dB

10

10

Cell

This parameter is valid only when "ATCBHo Switch" is set to OPEN, Read & "IUOTP" Write is set to EDB_cell, or "TIGHTB CCHSWI TCH" is set to ON.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Close, Open

None

Open

Open

BSC

If the resource usage on the Ater interface exceeds the value of "AterCong stRatio" and this Read & parameter Write is set to Open, the BSC preferenti ally selects TCHF when assigning traffic

N (No impact on Not the UE in involved idle mode)

80~100

per cent

85

85

BSC

This parameter is valid only when Read & "AterCong Write HRFlag" is set to OPEN.

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

MTP3 link None

Read & Write

Not involved

Not involved

0~100

per cent

90

90

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, None TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

E1/T1 link None

Read & Write

Not involved

Not involved

NO, YES None

None

None

BSC

None

Read & Write

Not involved

Not involved

0~1

None

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

ATERCO None NSL

Read & Write

Not involved

Not involved

TDM, IP

None

TDM

TDM

BSC

None

Read & Write

BSC6900

A, B, ALL None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, None TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

MTP3 link None

Read & Write

Not involved

Not involved

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

dB

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

dB

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

min

None

60

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

E1/T1 port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NONE, PEER

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

SERVER, None CLIENT

None

None

PPP link

None

Read & Write

PPP link

SERVER, None CLIENT

None

None

MP group None

Read & Write

BSC6900

SERVER, None CLIENT

None

None

BTS

None

Read & Write

PPP link

1~63 character None s

None

None

PPP link

None

Read & Write

BSC6900

1~63 character None s

None

None

MP group None

Read & Write

BSC6900

1~64 character None s

None

None

BTS

This parameter is required only when "Validate protocol type" is Read & set to Write "PAP_V" or "CHAP_V " with the "ADD PPPLNK" command .

PPP link

1~15 character None s

None

None

PPP link

None

Read & Write

PPP link

1~15 character None s

None

None

MP group None

Read & Write

BSC6900

1~16 character None s

None

None

BTS

This parameter is required only when "Validate protocol type" is Read & set to Write "PAP_V" or "CHAP_V " in the "ADD PPPLNK" command .

PPP link

NO_V, PAP_V, None CHAP_V

NO_V

NO_V

PPP link

None

Read & Write

PPP link

NO_V, PAP_V, None CHAP_V

NO_V

NO_V

MP group None

Read & Write

BSC6900

NO_V, PAP_V, None CHAP_V

NO_V

NO_V

BTS

None

Read & Write

PPP link

ENABLE, None DISABLE

None

ENABLE

Ethernet port

None

Read & Write

BSC6900

NO, YES None

YES

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE D, None ENABLE D

ENABLED

ENABLED

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BTSAUT ODLDAC T, None TMUAUT OACT

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

min

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

AU4, AU3 None

None

AU4

Channeliz ed optical None port

Read & Write

Optical port

GSM_PH ASE_1, GSM_PH ASE_2, None GSM_PH ASE_2Plu s

GSM_PHAS E_2 is recommende d in common scenarios. If AMR services, inter-RAT GSM_PHAS BSC handover, E_2 eMLPP, or A over IP mode needs to be supported, "GSM_PHAS E_2Plus" is recommende d.

Generally, the value of this parameter is equal to Read & "Um Write Interface Tag" and "Um Interface Tag".

N (No impact on Not the UE in involved idle mode)

LOW, HIGH

None

HIGH

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

LOW, HIGH

None

LOW

LOW

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

O1E3_R1 E4, O1E4_R1 E5, O1E5_R1 E6, O1E6_R1 E7, O1E7_R1 None E8, O1E8_R1 E9, O1E9_R1 E10, O1E10_R 1E11, O1E11_R 1E12

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

O1E3_R1 E4, O1E4_R1 E5, O1E5_R1 E6, O1E6_R1 E7, O1E7_R1 None E8, O1E8_R1 E9, O1E9_R1 E10, O1E10_R 1E11, O1E11_R 1E12

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

O1E4_R1 E5, O1E5_R1 E6, O1E6_R1 E7, O1E7_R1 None E8, O1E8_R1 E9, O1E9_R1 E10, O1E10_R 1E11

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

O1E4_R1 E5, O1E5_R1 E6, O1E6_R1 E7, O1E7_R1 None E8, O1E8_R1 E9, O1E9_R1 E10, O1E10_R 1E11

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~200 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~128 character None s

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~70

None

55

55

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, LOCALTL None LI, ALLTLLI

ALLTLLI

ALLTLLI

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYTRX, BYPWR

None

BYTRX

BYTRX

BTS

This parameter can work with "BTSPO WEROFF LOCKBC CH" in "SET BTSLOC Read & KBCCH" Write to determine whether to shut down the TRX that carries the main BCCH.

N (No impact on Not the UE in involved idle mode)

BYCOVE R, BYCAP, None BYSAVIN G

BYCOVER

BYCOVER

BTS

This parameter is valid only when Read & "BAKPW Write RSAVME THOD" is set to BYPWR.

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~200

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~80 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

Battery1T emp, None Battery2T emp

For EPS4815 boards, the value of this Battery1Tem parameter is BTS p always "Battery1Te mp".

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Battery1T emp, None Battery2T emp

Battery1Tem Battery1Tem BTS p p

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~1000

Ah

50

50

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~90

per cent

50

50

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO_BAT, INSIDE_B AT, None OUTSIDE _BAT

NO_BAT

NO_BAT

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1024~655 None 35

58000

58000

SCTP link None

Read & Write

SCTP link

0~254

None

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~5000

Ah

36

36

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

Cell

None

Read & Write

Cell

0~7

None

None

None

Cell

None

Read & Write

Cell

0~7

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1023

None

None

None

Cell

None

Read & Write

Cell

0~1023

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO_Hop, None Hop

None

None

Cell

None

Read & Write

Cell

0~100

per cent

80

80

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

60

60

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

14

14

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~511

None

None

None

BC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~25

per cent

15

If "Power System Type" is "APM30", the recommende d value is "7". For other BTS Power System Type, the recommende d value is "15".

None

Read & Write

N (No impact on Not the UE in involved idle mode)

43.3~57.6 V (step: 0.1)

565

565

BTS

The value of this parameter must be greater than "Float charging Read & voltage" Write and at least one volt lower than "DC Voltage Upper Threshold ".

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MTP3, M3UA, None MTP3_M3 UA

None

None

SCCP

None

Read & Write

Not involved

Not involved

1~60

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

NO, YES None

YES

YES

Cell

This parameter is valid only when the ""INTERR ATOUTB SCHOEN "" parameter regarding the "SET GCELLH OBASIC" command is set to YES. This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2.

Read & Write

N (No impact on Not the UE in involved idle mode)

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "BETTER CELLHO EN" is set to YES and "HOCTRL SWITCH" is set to HOALGO Read & RITHM2. Write The following condition must be met: "BETTER CELLSTA TTIME" >= "BETTER CELLLAS TTIME". This parameter is valid only when "BETTER CELLHO EN" is set to YES and "HOCTRL SWITCH" is set to HOALGO Read & RITHM2. Write The following condition must be met: "BETTER CELLSTA TTIME" >= "BETTER CELLLAS TTIME".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

N (No impact on Not the UE in involved idle mode)

3~10

None

Current BFD session

None

Read & Write

Not involved

Not involved

1~2

None

None

None

Current BFD session

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~254

None

30

30

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

ALL, PART

None

ALL

ALL

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10000~10 None 000

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

ENABLE

None

If you set "Switch of stat blinking alarm" to "ENABLE ", you Read & BSC6900 need to Write set "Alarm switch of blinking filter" to "ENABLE ".

N (No impact on Not the UE in involved idle mode)

0~65534

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

60~65534 s

900

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

ENABLE

None

If you set "Switch of stat blinking alarm" to "ENABLE ", you Read & BSC6900 need to Write set "Alarm switch of blinking filter" to "ENABLE ".

N (No impact on Not the UE in involved idle mode)

1~6

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~120

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

Transport None channel

Read & Write

Not involved

Not involved

0~5, 8~27 None

None

None

Transport None channel

Read & Write

Not involved

Not involved

0~11

None

None

None

Transport None channel

Read & Write

Not involved

Not involved

0~5000

1000

1000

BSC

This parameter is valid when "BMTCFF LAG" in Read & the "SET Write BSCFCP ARA" command is set to ON.

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

NO

MP group None

Read & Write

Not involved

Not involved

nonrpt, rpt None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 1, 2, 3, 4, 5, 6, None NULL

NULL

NULL

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 1, 2, 3, 4, 5, 6, None NULL

NULL

NULL

BTS

The value of this parameter must be greater Read & than or Write equal to "Position of Break Point 1".

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~8, step:0.5

Cell

This parameter is valid only when "BQHOE N" is set to YES and "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2. The following condition must be met: "BQSTAT TIME" >= "BQLAST TIME".

N (No impact on Not the UE in involved idle mode)

0~127

dB

69

69

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~8, step:0.5

Cell

This parameter is valid only when "BQHOE N" is set to YES and "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2. The following condition must be met: "BQSTAT TIME" >= "BQLAST TIME".

N (No impact on Not the UE in involved idle mode)

SCU, GCU, None XPU, INT, TNU

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SCU, GCU, XPU, None DPU, INT, TNU

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SCU, GCU, MPU, None GCP, DPU, INT, TNU

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INT, DPU, XPU, TNU, None OMU, SAU

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~72

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~47

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100000 (step: kbit/s 100)

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DATM_M AIN, DATU_M AIN, DDPM_M AIN, DDPU_M AIN, DDRM_M AIN, DEMU_M AIN, DFCU_M AIN, DGPS_M AIN, DHEU_M None AIN, DOMU_M AIN, DPMU_M AIN, DPTU_M AIN, DRFU_M AIN, DRFUBO OT_MAIN , DRRU_M AIN, DRRUBO OT_MAIN ,

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100000 (step: kbit/s 100)

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DPUa, DPUc

None

None

None

Board

None

Read & Write

BSC6900

PEUa, FG2a, GOUa, EIUa, OIUa, POUc, FG2c, GOUc, XPUa, XPUb, DPUa, DPUb, DPUc, DPUd, TNUa, OMUa, OMUb, SAUa

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FG2a, GOUa, FG2c, GOUc

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

PEUa, POUc

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

PEUa, POUc

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

PEUa, POUc

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

MRRU, GRRU, MRFU, None GRFU, BTS3900 E

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TMU, DTRU, DPTU, QTRU, MRRU, GRRU, BTS3900 None B, MRFU, GRFU, BTS3900 E, DRFU, DRRU, UBRI, UTRP

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

BTS

The setting of this parameter must meet the following condition: "FallBack Start Read & Time" > Write "Ring II Wait Time Before Switch" + "Ring II Try Rotating Duration Time".

N (No impact on Not the UE in involved idle mode)

1~80 character None s

Cell name

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~3600

60

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ENTIRE, INCREM ENTAL

None

INCREMENT None AL

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~167772 None 15

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MAINBSC , None SUBBSC

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

hour{0~2 3} None min{0~59}

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

hour{0~2 3} None min{0~59}

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

None

None

Adjacent node

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~60

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

The IP address must Read & have Write been configure d.

BTS

UNCOND ITIONALS TART, ATERCO None NGESTS, PREFIXN UMBER

UNCONDITI UNCONDITI BSC ONALSTART ONALSTART

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

This parameter is valid Read & only when Write "BSCPMA " is set to YES.

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

When "BSCPMA " is set to YES and "BSCQAD " is also set to Yes, highpriority calls try to preempt radio resources of lowpriority calls Read & firstly if Write radio resources are insufficien t. If no radio resources of lowpriority calls can be preempte d, then the highpriority calls are put into

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

This parameter is valid Read & only when Write "BSCQAD " is set to YES.

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

65535

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

65535

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

65535

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

65535

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

65535

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

65535

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

65535

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

65535

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2500

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

None

None

When configure TC data, for example, select TC for "BM/TC Read & E1/T1 link config Write Flag", or MTP2 for "Applicati on Type", the parameter should be set.

N (No impact on Not the UE in involved idle mode)

1~15

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter must be set when "BTSMES Read & RPTPRE Write PROC" is set to BTS_Pre processin gN.

N (No impact on Not the UE in involved idle mode)

0~12

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

940~4230 , step: ms 470

2_M_PERIO 2_M_PERIO Cell D D

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~4

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~12

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NEITHER START, BTSPRIO RITY, BSCPRIO None RITY, BTSONL Y, BSCONL Y

NEITHERST NEITHERST BSC ART ART

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NONSUP PORT, BASIC, None ENHANC ED

NONSUPPO NONSUPPO MSC RT RT

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PEUa, EIUa, OIUa, POUc

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SCUa, GCUa, GCGa, PEUa, FG2a, GOUa, EIUa, OIUa, POUc, FG2c, GOUc, XPUa, XPUb, DPUa, DPUb, DPUc, DPUd, TNUa

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SCUa, GCUa, GCGa, PEUa, FG2a, GOUa, EIUa, OIUa, POUc, FG2c, GOUc, XPUa, XPUb, DPUa, DPUb, DPUc, DPUd, TNUa, ALL

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PEUa, POUc, EIUa, OIUa

None

None

None

E1/T1 port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PEUa, POUc, EIUa

None

None

None

Cell

None

Read & Write

Cell

PEUa, POUc, EIUa, OIUa POUc, OIUa

None

None

None

E1/T1 port

None

Read & Write

Not involved

Not involved

None

None

None

Board

None

Read & Write

Not involved

Not involved

POUc, OIUa

None

None

None

Channeliz ed optical None port

Read & Write

Not involved

Not involved

FG2a, GOUa, FG2c, GOUc, POUc

None

None

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

EIUa

None

None

None

E1/T1 port

None

Read & Write

Not involved

Not involved

DATU, GATM, DRRU, MRRU, MRFU, None GRFU, GRRU, BTS3900 E

None

None

BTS

None

Read & Write

Not involved

Not involved

CDU, PCDU, DCDU, CDUC, CDUP, RCDU, CDUR, CDUE, EDU, PEDU, None REDU, DEDU, EDUC, EDUP, EDUR, EDUE, DDPM_D DPU, DFCU, DFCB

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BIE, PWC, EAC, EMUA, MCK, DTMU, DATM_D ATU, NFCB, EMU_DE MU, DPMU, DCBM_D COM, DHEU, ECOM, MFU, None MPW, MCD, IASU, PTU, TMU, PSU, PMU, APMU, 3001C_M FU, TEU, TES, PBU, DPBU, RPBU, PPBU, SCU, MDU,

None

None

BTS

The value range of this parameter varies with BTS type. Read & Different Write types of BTSs support different type of boards.

N (No impact on Not the UE in involved idle mode)

DRRU, DRFU, MRRU, XRRU, MRFU, None GRFU, GRRU, XRFU, BTS3900 E

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TRX_30_ OR_DRU, TRX_GP RS, PTRX, ETRX, RTRX, DTRX, None RETR, DETR, EETR, PETR, MTR, TRU, QTRU

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CDU, CDUC, CDUP, CDUR, CDUE, PCDU, RCDU, DCDU, EDU, EDUC, None EDUP, EDUR, EDUE, PEDU, REDU, DEDU, DDPM_D DPU, DFCU, DFCB

None

None

BTS

None

Read & Write

Not involved

Not involved

CFGBM, CFGTC

None

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

CFGBM, CFGTC

None

None

None

ATERCO None NSL

Read & Write

Not involved

Not involved

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

LOGICIP, PORTIP, None PPP/MP

LOGICIP

LOGICIP

BTS

None

Read & Write

BTS

LOGICIP, PORTIP, None PPP/MP

None

None

BTS

None

Read & Write

BTS

0~64 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

Adjacent node

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

BTS

None

Read & Write

Not involved

Not involved

0~2047

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~2047

None

None

None

BTS

None

Read & Write

Not involved

Not involved

0~2047

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYIDX, None BYNAME

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047, 65535

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

BTS

UNCOND ITIONALS TART, ABISCON None GESTS, PREFIXN UMBER

UNCONDITI UNCONDITI BSC ONALSTART ONALSTART

The value of BtsLsStar tMode should be set when "BssLsGe Read & nMode" is Write set to BTSPRIO RITY, BSCPRIO RITY, or BTSONL Y.

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BSC_Pre processin g, None BTS_Pre processin g

BTS_Preproc BTS_Preproc Cell essing essing

If the value of this parameter is BSC_Pre processin g, the preprocessin g is performe d on the Read & BSC. In this case, Write the following parameter s are invalid: "PRIMME SPPT", "BSMSP WRLEV", and "MRPRE PROCFR

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BTS

None

Read & Write

Not involved

Not involved

1~2048 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~32, step:2

dB

16

16

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~256 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~250

None

None

None

BTS

This parameter is used to caculate BindWidt h of BTSAbis HDLCPat h: 1. When Transmis sion compress ion ratio is within range of [1, 200], Read & BindWidt Write h=16K*(a mount of TRXs) + 64K*(amo unt of TRXs)*(Tr ansmissio n compress ion ratio)/100; 2. When Transmis sion compress ion ratio is

N (No impact on Not the UE in involved idle mode)

BTS30, BTS312, BTS3001 C, BTS3001 CP, BTS3002 C, BTS3012 A, BTS3006 A, BTS3012, BTS3006 C, BTS3002 E, None BTS3012 AE, BTS3012 _II, DBS3900 _GSM, BTS3900 _GSM, BTS3900 A_GSM, DBS3036, BTS3036, BTS3036 A, BTS3900 B_GSM, BTS3900 BTS3900 B_GSM, None BTS3900 E_GSM

None

None

BTS

None

Read & Write

Not involved

Not involved

None

None

BTS

None

Read & Write

Not involved

Not involved

BTS3012, BTS3006 C, BTS3002 E, BTS3012 AE, BTS3012 _II, DBS3900 _GSM, BTS3900 _GSM, None BTS3900 A_GSM, DBS3036, BTS3036, BTS3036 A, BTS3900 L_GSM, BTS3900 B_GSM, BTS3900 E_GSM

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100000 s 0

Current BFD session

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BIULOOP , None TRXSELF TEST

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO_BAT, INSIDE_B AT, None OUTSIDE _BAT

NO_BAT

NO_BAT

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~255

60

60

BTS

The setting of this parameter must meet the following condition: "FallBack Start Read & Time" > Write "Ring II Wait Time Before Switch" + "Ring II Try Rotating Duration Time".

N (No impact on Not the UE in involved idle mode)

YES, NO None

NO

NO

SCTP link None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~65534

None

None

None

Cell

None

Read & Write

Not involved

Not involved

2~65534

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~300 ms 0

1000

1000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

The dynamic bandwidth switch is turned IP logical only when Read & port the IPPM Write function is activated through "ACT IPPM".

Not involved

Not involved

0~200000 kbit/s

BSC6900 None

Read & Write

Not involved

Not involved

0~200000 kbit/s

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

20

20

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

15

15

BSC6900 None

Read & Write

Not involved

Not involved

0~200000 kbit/s

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

BSC6900 None

Read & Write

Not involved

Not involved

0~200000 kbit/s

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

BSC6900 None

Read & Write

Not involved

Not involved

0~200000 kbit/s

BSC6900 None

Read & Write

Not involved

Not involved

100~1000 per cent

120

120

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

FULL_DU PLEX, None HALF_DU PLEX

None

None

When "GRPT" in Transmis "ADD sion RSCGRP Read & resource " is set to Write group IP, this parameter is valid.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

25

25

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

20~100

per cent

80

80

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

BYIDX, None BYNAME

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

C31NOT USE, None C31STAN DARD

C31STANDA C31STANDA Cell RD RD

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~200 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~8

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

None

None

Read & Write

Not involved

Not involved

NO, YES None

YES

If this parameter is set to NO, the average call drop rate decreases. This setting is applicable in suburbs or urban areas with poor coverage. Call reestablishm Cell ent, however, may take a long time. Therefore, the subscriber may hang up the phone before the call is reestablished. Generally, the

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~4095

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

GSM900, DCS1800 , None GSM850, PCS1900

GSM900

GSM900

BTS

This parameter has relations Read & with Write DCOM, DCBM board

N (No impact on Not the UE in involved idle mode)

NULL, IPLGCPO None RT, RSCGRP

NULL

NULL

IP path

None

Read & Write

IP path

ETHER, IPLOGIC PORT, None TRUNK, PPP, MP ETHPOR T, None TRUNK

None

None

IP logical None port

Read & Write

Not involved

Not involved

None

None

None

None

Read & Write

Not involved

Not involved

NO, YES None

NO

The CBA function applies to special scenarios. If this parameter is set to YES and "Cell Bar Qualify" is set to no, only handovers are allowed in a cell, and Cell direct access of an MS is not allowed. This condition applies to a dual-network coverage cell. For a common cell, this parameter should be set to NO.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

None

None

BSC

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

30

30

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~180

15

15

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

4500~327 byte 67

4500

4500

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

1~5

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:0~1 4880, step:480; ms SDCCH:0 ~14570, step:470

Cell

This parameter is valid only when "MEASU RETYPE" Read & in "SET Write GCELLC CUTRAN SYS" is set to EnhMeas Report.

N (No impact on Not the UE in involved idle mode)

TCH:0~1 4880, step:480; ms SDCCH:0 ~14570, step:470

Cell

This parameter is valid only when "MEASU RETYPE" Read & in "SET Write GCELLC CUTRAN SYS" is set to EnhMeas Report.

N (No impact on Not the UE in involved idle mode)

0~65535

None

86

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

20~100

per cent

80

80

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

46

46

BSC

None

Read & Write

Not involved

Not involved

10, 100, 1000

ms

1000

1000

Ethernet port

None

Read & Write

Not involved

Not involved

0~100

per cent

90

90

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~42, step: 6

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~36, Positive infinity, step: 6

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1023

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

AUTO, MANU

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1023

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

AUTO, MANU

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~50

None

Cell

This parameter is valid only when "EDGE" in Read & "SET Write GCELLG PRS" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~42, step: 6

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~36, Positive infinity, step: 6

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Permit, None NoPermit

Permit

Permit

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OUTDOO R_CELL, None INDOOR_ CELL

OUTDOOR_ OUTDOOR_ Cell CELL CELL

None

Read & Write

N (No impact on Not the UE in involved idle mode)

24.0~28.9 V (step: 0.1)

283

283

BTS

The value of this parameter must be greater than "Float charging Read & voltage" Write and at least one volt lower than "DC overvolta ge alarm threshold"

N (No impact on Not the UE in involved idle mode)

43.3~57.6 V (step: 0.1)

565

565

BTS

The value of this parameter must be greater than "Float charging voltage" Read & and at Write least three volts lower than "DC overvolta ge alarm threshold" .

N (No impact on Not the UE in involved idle mode)

24.0~28.9 V (step: 0.1)

268

268

BTS

The value of this parameter must be Read & smaller Write than "Even Charging Voltage".

N (No impact on Not the UE in involved idle mode)

43.2~57.5 V (step: 0.1)

535

535

BTS

The value of this parameter must be Read & smaller Write than "Even Charging Voltage".

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047, 65535

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32768 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Inner, Extra

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1, 2, 3, 4

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5000 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

80

80

Cell

This parameter is valid only when "SDDYN" Read & in "SET Write GCELLB ASICPAR A" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5000 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OP1, OP2, OP3, OP4, NONE

None

255

255

Cell

The parameter value correspon ds to the power of each passage on the MRRU. If the cell is configure d only on Read & Write one passage of the MRRU, then the power assigned to another passage of the operator must be set to 0.

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~20

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

35.0~55.3 V (step: 0.1)

430

430

BTS

The value of this parameter must be smaller Read & than "DC Write undervolt age alarm threshold" .

N (No impact on Not the UE in involved idle mode)

2G, 3G

None

2G

2G

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

COMMO N, MULTIPA TH, None INDOOR, HIGHWA Y

COMMON

COMMON

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

40.0~79.0 degree (step: 0.1) Celsius

500

500

BTS

The value of this parameter must be smaller Read & than "Low Write Temp Alarm Assemble d Bat2".

N (No impact on Not the UE in involved idle mode)

-19.0~5.0 degree (step: 0.1) Celsius

-100

-100

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0~100.0 degree (step: 0.1) Celsius

800

800

BTS

The value of this parameter must be greater Read & than Write "Lower Assemble d Bat1 TEMP Measure".

N (No impact on Not the UE in involved idle mode)

-50.0~0.0 degree (step: 0.1) Celsius

-200

-200

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

20~90

per cent

80

80

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~200 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NULL, IPLGCPO None RT, RSCGRP

NULL

NULL

IP path

None

Read & Write

IP path

AUTO, None NORMAL

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

G_15, G_16, G_17, G_18, G_19, G_20, G_21, G_22, G_23, G_24, G_25, G_26, G_27, G_28, G_29, G_30, G_31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

G_0, G_1, G_2, G_3, G_4, G_5, G_6, G_7, G_8, G_9, G_10, G_11, G_12, G_13, G_14, G_15, G_16, G_17, G_18, G_19, G_20, G_21, G_22, G_23, G_24, G_25, G_26, G_27, G_28, G_29, G_30, G_31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

20~90

None

80

80

ATERCO None NSL

Read & Write

N (No impact on Not the UE in involved idle mode)

20~90

None

80

80

ATERCO None NSL

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

None

90

90

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

None

90

90

ATERCO None NSL

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

None

90

90

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

QUICK_H O_NCELL _TYPE_A , None QUICK_H O_NCELL _TYPE_B

QUICK_HO_ QUICK_HO_ NCELL_TYP NCELL_TYP Cell E_A E_A

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CHAINTO RING, None COMBIN ECHAINS

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CAPABILI TY, QUALITY, PSRELAT None IVELY, PSABSO LUTELY

CAPABILITY CAPABILITY Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

100

100

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~5

None

IP path

When the value of "PATHCH K" in "ADD Read & IPPATH" Write is set to ENABLE D, this parameter is valid.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MODE1, MODE2, MODE3

None

MODE2

MODE2

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MODE1, MODE2, MODE3

None

MODE2

MODE2

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~511

None

None

None

None

None

Read & Write

Not involved

Not involved

0~511

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~20

None

10

10

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~20

None

10

10

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

SCTP link None

Read & Write

SCTP link

NO, YES None

NO

NO

SCTP link None

Read & Write

SCTP link

ALDER32 None , CRC32

CRC32

CRC32

SCTP link None

Read & Write

SCTP link

SBFD, ARP, MBFD

None

None

None

None

None

Read & Write

Not involved

Not involved

0~12

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~7

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~169

None

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

Physical channel

None

Read & Write

Not involved

Not involved

TRXRFS ELFLOO P, BIULOOP , None BTSSPEE CHLOOP, TRXSPE ECHLOO P

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FULLTCH , None HALFTC H

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOSENDI NG, SYSTEM None OPT, SENDING

SYSTEMOP SYSTEMOP MSC T T

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when Read & "QTRUP Write WRSHAR E" is not set to NONE.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~800

None

100

100

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~800

None

200

200

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

100~6000 ms 00

1000

1000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCHFR, TCHHR, SDCCH8, MBCCH, CBCCH, BCH, BCCH_C BCH, None SDCCH_ CBCH, PBCCH_ PDTCH, PCCCH_ PDTCH, PDTCH, DPDCH

TCHFR

TCHFR

Physical channel

None

Read & Write

Channel

0~65535

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

When the value of "OPMOD E" of "BLK ACIC" is Read & E1/T1 link BYCICVA Write LUE, the value of CIC needs to be set.

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

None

None

Read & Write

Not involved

Not involved

0~160

frame

BSC

None

Read & Write

Not involved

Not involved

1~12, step: 5

min

BSC

None

Read & Write

Not involved

Not involved

OFF, ON None

OFF

OFF

BSC

None

Read & Write

Not involved

Not involved

1~100

per cent

80

80

BSC

None

Read & Write

Not involved

Not involved

1~60

BSC

None

Read & Write

Not involved

Not involved

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOTSEN DING, SENDING None PRO, SENDING

NOTSENDIN NOTSENDIN MSC G G

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOTSEN DING, SENDING None PRO, SENDING

NOTSENDIN NOTSENDIN MSC G G

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

64~10000 kbit/s 0, step:64

None

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~22

dB

22

22

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

BSC6900 None

Read & Write

BTS

0~11

None

None

None

BSC6900 None

Read & Write

BTS

UNSUPP ORT, None SUPPOR T

UNSUPPOR None T

Cell

This parameter is valid only when "GPRS" is set to SupportA Read & sInnPcu Write and "SUPPOR TDTM" is set to SUPPOR T.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ERR_PF M_1E6, ERR_PF M_5E6, ERR_PF M_1E5, ERR_PF M_5E5, ERR_PF M_1E4, ERR_PF M_5E4, ERR_PF M_1E3

None

None

ERR_PFM_5 Board E6

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INCLK, BSCCLK, EXCLK, IPCLK, TRANSC None LK, GPSCLK, UMCLK, PEERCL K

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HW_DEFI NED, None PTP

PTP

PTP

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

GCUa, GCGa

None

GCUa

None

BSC6900 None

Read & Write

BSC6900

INT_CLK, TRCBSC _CLK, EXTSYN_ CLK, IP_TIME, IP_TRAN None SFER, TRCGPS _CLK, UM_CLK, PEER_CL K

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

255

255

BTS

This parameter is valid only when Read & "AntiTheft Write Allow" is set to YES.

N (No impact on Not the UE in involved idle mode)

cleared, None uncleared

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

255

255

BTS

This parameter is valid only when Read & "AntiTheft Write Allow" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~200 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~128 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~19

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~3

None

None

None

None

None

Read & Write

Not involved

Not involved

0~62

None

None

None

BTS

The value range of this parameter varies with BTS type. Read & Different Write types of BTSs support a different number of cabinets.

N (No impact on Not the UE in involved idle mode)

0~62

None

BTS

The value range of this parameter varies with BTS type. Read & Different Write types of BTSs support a different number of cabinets.

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BSC6900 None

Read & Write

BTS

0~62

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~4095

None

None

None

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~4095

None

None

None

NSE

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

BSC

None

Read & Write

Not involved

Not involved

0~3

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NONE, AINTFBL None OCK

NONE

NONE

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~150000 None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

BTS3002 C, BTS3012 None A, BTS3006 A

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BTS3012, BTS3012 AE, BTS3006 C, BTS3012 _II, BTS3002 E, DBS3900 _GSM, BTS3900 _GSM, BTS3900 A_GSM, None DBS3036, BTS3036, BTS3036 A, BTS3900 _GSM_6 RFC, BTS3900 A_GSM_ 6RFC, BTS3036 _6RFC, BTS3036 A_6RFC

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10000~50 None 000

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~250

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~250

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~1023

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INACTIV E, ACTIVE

None

INACTIVE

INACTIVE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYSITE, BYCELL

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, step:0.1

dB

45

45

Cell

This parameter is valid only when Read & "PWRBC Write DALLOW D" is set to YES.

N (No impact on Not the UE in involved idle mode)

L0_FORB ID, L1_FORB ID, L2_FORB ID, L3_FORB ID, L4_FORB ID, None L5_FORB ID, L6_FORB ID, L7_FORB ID, L8_FORB ID, L9_FORB ID

L0_FORBID0&L1_FORBI D0&L2_FORBI D0&L3_FORBI D0&L4_FORBI D0&L5_FORBI D0&L6_FORBI D0&L7_FORBI D0&L8_FORBI D0&L9_FORBI D-0

L0_FORBID0&L1_FORBI D0&L2_FORBI D0&L3_FORBI D0&L4_FORBI D0&L5_FORBI Cell D0&L6_FORBI D0&L7_FORBI D0&L8_FORBI D0&L9_FORBI D-0

None

Read & Write

N (No impact on Not the UE in involved idle mode)

LOWERC ASE, UPPERC ASE, None DIGIT, SPECIAL CHARAC TER

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~100

None

100

100

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

BTS

None

Read & Write

Not involved

Not involved

10~150

ms

15

IP/HDLC:15

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

15

IP/HDLC:15

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

15

IP/HDLC:15

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

15

IP/HDLC:15

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

25

25

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

25

25

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

25

IP/HDLC:25

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

25

IP/HDLC:25

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

25

IP/HDLC:25

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

25

IP/HDLC:25

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

50

50

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

50

50

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

BSC6900 None

Read & Write

BTS

NO, YES None

NO

NO

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ALL, ONLY_SS None L

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

INNER, EXTERN None AL

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~200

Cell

This parameter , together with "BANTIM Read & E", limits Write the handover frequency in the cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Ethernet port

None

Read & Write

Not involved

Not involved

1~28

None

Ethernet port

None

Read & Write

Not involved

Not involved

1~60

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

TRX

This parameter is valid only when "BSCDyn SwitchTrx PAAllow" in "SET Read & BSCDST Write PA" and "DYNOpe nTrxPowe r" in "SET GCELLB ASICPAR A" are set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON, NOTSUP None PORT

NOTSUPPO NOTSUPPO BTS RT RT

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0dB, 2dB, 4dB, 6dB, 8dB, dB 10dB, 12dB, 14dB

6dB

6dB

Cell

None

Read & Write

N (Impact on the UE Not in idle involved mode)

0~200 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~2550, ms step: 10

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~126, step: 2

dB

Cell

None

Read & Write

N (Impact on the UE Not in idle involved mode)

1~255

None

255

255

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

UNAVAIL ABLE, None AVAILAB LE

UNAVAILAB UNAVAILAB SCTP link None LE LE

Read & Write

N (No impact on Not the UE in involved idle mode)

VOICEIN F, MR, CALLAPP None ENDINF, CALLINN ERINF

None

None

BSC

This parameter is valid only when "CHR Read & Output Write Mode" is set to "Common User Mode".

N (No impact on Not the UE in involved idle mode)

0~100

None

BSC

This parameter is valid only when "CHR Read & Output Write Mode" is set to "Common User Mode". This parameter is valid only when "CHR Read & Output Write Mode" is set to "Specified User Mode". This parameter is valid only when "CHR Read & Output Write Mode" is set to "Common User Mode".

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC

N (No impact on Not the UE in involved idle mode)

RESINSU FF, UMABNO RM, TRAFFR EJECT, None MSCREL, MSCDIS CON, BADQUA LITY

RESINSUFF, UMABNORM ,TRAFFREJ ECT,MSCRE L

RESINSUFF, UMABNORM ,TRAFFREJ BSC ECT,MSCRE L

N (No impact on Not the UE in involved idle mode)

0~100

per cent

100

100

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

BE, AF11, AF12, AF13, AF21, AF22, AF23, None AF31, AF32, AF33, AF41, AF42, AF43, EF

None

When the interface type When the is Abis, value of transmission "ITFT" in type is IP, the "ADD parameter is TRMMAP Read & AF43; When BSC6900 " is set to Write the interface A or type is A, ABIS, this Ater or Iur-g, parameter the is valid. parameter is AF43.

N (No impact on Not the UE in involved idle mode)

0~7

None

None

When the When the value of interface type "ITFT" in is Abis and "ADD transmission Read & BSC6900 TRMMAP type is Write " is set to HDLC, the ABIS, this parameter is parameter 1. is valid.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

100

100

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC

This parameter is valid only when "CHR Read & Output Write Mode" is set to "Common User Mode". This parameter is valid only when "CHR Read & Output Write Mode" is set to "Common User Mode".

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC

N (No impact on Not the UE in involved idle mode)

OFF, MRHOFA IL, None MRHOLA TEST

OFF

OFF

BSC

This parameter is valid only when "CHR Read & Output Write Mode" is set to "Common User Mode".

N (No impact on Not the UE in involved idle mode)

COMMO NUSRM, None SPECUS RM

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ABNORM REC, ALLBSCR None EC, ALLCELL REC

ABNORMRE ABNORMRE BSC C C

This parameter is valid only when "CHR Read & Output Write Mode" is set to "Common User Mode".

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

ON

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ALL, None AINTF, ABISINTF

OFF

OFF

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

90

90

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

LU, SMS, None CALL

CALL

CALL

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

50

50

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC

This parameter is valid only when "CHR Read & Output Write Mode" is set to "Specified User Mode".

N (No impact on Not the UE in involved idle mode)

BE, AF11, AF12, AF13, AF21, AF22, AF23, None AF31, AF32, AF33, AF41, AF42, AF43, EF

None

When the interface type When the is Abis, value of transmission "ITFT" in type is IP, the "ADD parameter is TRMMAP Read & EF; When BSC6900 " is set to Write the interface A or type is A, ABIS, this Ater or Iur-g, parameter the is valid. parameter is EF.

N (No impact on Not the UE in involved idle mode)

0~7

None

None

When the When the value of interface type "ITFT" in is Abis and "ADD transmission Read & BSC6900 TRMMAP type is Write " is set to HDLC, the ABIS, this parameter is parameter 1. is valid.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

50

50

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

None

ON

BSC6900 none

Read & Write

N (No impact on Not the UE in involved idle mode)

40000~50 ms 000

45000

45000

None

None

Read & Write

BSC6900

5000~150 ms 000

30000

30000

None

None

Read & Write

BSC6900

1000~200 ms 0

1300

1300

None

None

Read & Write

BSC6900

400~600

ms

500

500

None

None

Read & Write

BSC6900

7500~950 ms 0

8200

8200

None

None

Read & Write

BSC6900

80~120

ms

100

100

None

None

Read & Write

BSC6900

3000~600 ms 0

5000

5000

None

None

Read & Write

BSC6900

500~2000 ms

1500

1500

None

None

Read & Write

BSC6900

1~100

ms

100

100

None

None

Read & Write

BSC6900

30~100

per cent

95

95

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

95

85

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~167772 None 15

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

4BURST, None RLC/MAC

4BURST

4BURST

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

YES, NO None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BTS

The value range of this parameter varies with BTS type. Read & Different Write types of BTSs support a different number of cabinets.

N (No impact on Not the UE in involved idle mode)

0~5

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 2, 4, 8, 10, 12, 14, 16, None 18, 20, 22, 24, 26

None

None

Transmis sion None resource group

Read & Write

Not involved

Not involved

0~27, 255 None

None

None

BTS

None

Read & Write

BTS

0~11, 255 None

None

None

BTS

None

Read & Write

BTS

ON, OFF None

None

OFF

BSC6900 None

Read & Write

Not involved

Not involved

NO, YES None

NO

NO

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~99

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~255

min

30

None

None

None

Read & Write

Not involved

Not involved

1~63 None character

None

None

None

None

Read & Write

BSC6900

TCH:480 ~14880, step:480; ms SDCCH:4 70~14570 , step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~14880, step:480; ms SDCCH:4 70~14570 , step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NT14_5K, NT12K, NT6K, T14_4K, T9_6K, T4_8K, None T2_4K, T1_2K, T600_BIT S, T1200_75

NT14_5K0&NT12K1&NT6K1&T14_4K0&T9_6K1&T4_8K1&T2_4K1&T1_2K0&T600_BIT S0&T1200_750

NT14_5K0&NT12K1&NT6K1&T14_4K0&T9_6K1&T4_8KCell 1&T2_4K1&T1_2K0&T600_BIT S0&T1200_750

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOLIMIT, None LIMIT

NOLIMIT

NOLIMIT

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-11~209912-31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~12

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~30

degree Celsius

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Inner, Extra

None

None

If the coverage area in the underlaid subcell is large and tight frequency reuse is used in the overlaid subcell, the Cell recommende d value is Inner. If the coverage areas in the overlaid and underlaid subcells are similar and tight frequency

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

The value range of this parameter varies with BTS type. Read & Different Write types of BTSs support a different number of cabinets.

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

The value range of this Read & parameter Write varies with BTS type.

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

35.0~55.6 V (step: 0.1)

None

If "Power System Type" is "SC48200", the recommende d value is BTS "470". For Power System Type, the recommende d value is "450".

The value of this parameter must be greater than "Battery power-off voltage", lower than "DC Read & overvolta Write ge alarm threshold" , and at least two volts lower than "Float charging voltage".

N (No impact on Not the UE in involved idle mode)

58.0~60.0 V (step: 0.1)

580

580

BTS

The value of this parameter must be greater than "DC undervolt age alarm Read & threshold" Write and at least two volts greater than "Even charging voltage".

N (No impact on Not the UE in involved idle mode)

43.3~55.5 V (step: 0.1)

450

450

BTS

The value of this parameter must be greater than "Battery power-off voltage", lower than "DC Read & overvolta Write ge alarm threshold" , and at least three volts lower than "Float charging voltage".

N (No impact on Not the UE in involved idle mode)

58.0~60.0 V (step: 0.1)

580

580

BTS

The value of this parameter must be greater than "DC Voltage Lower Read & Threshold Write " and at least one volt greater than "Even charging voltage".

N (No impact on Not the UE in involved idle mode)

0~32

None

Cell

None

Read & Write

Cell

500~6000 ms 0

1000

1000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~186

None

None

None

SCCP

None

Read & Write

Not involved

Not involved

1~110 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

INACTIV E, ACTIVE

None

INACTIVE

INACTIVE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255 0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

Not involved

Not involved

None

None

None

None

Read & Write

Not involved

Not involved

1~1000

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

BSC, BTS None

None

None

BTS

None

Read & Write

BTS

BTS, BSC, DXX, OTHER

None

None

None

BTS

None

Read & Write

BTS

0~27

None

None

None

BSC

This parameter is required Read & when the Write Connectio n Type is Internal RNC.

N (No impact on Not the UE in involved idle mode)

{0~11}

None

None

None

BSC

This parameter is required Read & when the Write Connectio n Type is Internal RNC.

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

BSC

This parameter is required Read & when the Write Connectio n Type is Internal RNC.

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

Cell

0~255

None

Cell

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

3~10

None

Current BFD session

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

OFF

BSC6900 None

Read & Write

Not involved

Not involved

0~50 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~35

None

None

None

BTS

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

Not involved

Not involved

LOGIC_I P

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~16383

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DEFAULT PORT, None CUSTOM PORT

None

DEFAULTPO BSC6900 None RT

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

DISABLE, None ENABLE

DISABLE

DISABLE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MON_1~ None MON_31

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

SUN, MON, TUE, None WED, THU, FRI, SAT

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~128 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~256 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~4, step: 1/8

bit

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~4, step: 1/8

bit

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~4, step: 1/8

bit

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

N0, YES

None

N0

N0

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~122400, step:480; SDCCH:4 ms 70~11985 0, step:470

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

1~30

dB

14

14

Cell

1~30

dB

14

14

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The following condition must be met: "DLAFSR EXQUAL HIGHTHR ED" >= "DLAFSR EXQUAL LOWTHR ED". This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The following condition must be met: "DLAFSR EXQUAL HIGHTHR ED" >= "DLAFSR EXQUAL LOWTHR ED".

Read & Write

N (No impact on Not the UE in involved idle mode)

Read & Write

N (No impact on Not the UE in involved idle mode)

1~30

dB

16

16

Cell

1~30

dB

16

16

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The following condition must be met: "DLAHSR EXQUAL HIGHTHR ED" >= "DLAFSR EXQUAL LOWTHR ED". This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The following condition must be met: "DLAHSR EXQUAL HIGHTHR ED" >= "DLAFSR EXQUAL LOWTHR ED".

Read & Write

N (No impact on Not the UE in involved idle mode)

Read & Write

N (No impact on Not the UE in involved idle mode)

16~1007

None

None

None

NSVC

None

Read & Write

NSVC

1~255

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

UNSUPP ORT, None SUPPOR T

UNSUPPOR None T

Cell

This parameter is valid only when Read & "GPRS" is Write set to SupportA sInnPcu.

N (No impact on Not the UE in involved idle mode)

0~63

dB

20

The recommende d value is 20 when HUAWEI I Handover is used; Cell The recommende d value is 15 when HUAWEI II Handover is used.

This parameter is valid when "FRINGE Read & HOEN" is Write set to YES or "LOADHO EN" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

This parameter is valid only when Read & "PWRCT Write RLOPTIM IZEDEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~30

dB

16

16

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "DLFSRE XQUALHI GHTHRE D" >= "DLFSRE XQUALL OWTHRE D".

N (No impact on Not the UE in involved idle mode)

1~30

dB

16

16

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "DLFSRE XQUALHI GHTHRE D" >= "DLFSRE XQUALL OWTHRE D".

N (No impact on Not the UE in involved idle mode)

0~127

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~30

dB

18

18

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "DLHSRE XQUALHI GHTHRE D" >= "DLHSRE XQUALL OWTHRE D".

N (No impact on Not the UE in involved idle mode)

1~30

dB

18

18

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "DLHSRE XQUALHI GHTHRE D" >= "DLHSRE XQUALL OWTHRE D".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "DLTHF1" Write + "DLHYST F1" < "DLTHF2" + "DLHYST F2".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "DLTHF2" Write + "DLHYST F2" < "DLTHF3" + "DLHYST F3".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "DLTHF2" Write + "DLHYST F2" < "DLTHF3" + "DLHYST F3".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "DLTHH1 Write "+ "DLHYST H1" < "DLTHH2 "+ "DLHYST H2".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "DLTHH2 Write "+ "DLHYST H2" < "DLTHH3 "+ "DLHYST H3".

N (No impact on Not the UE in involved idle mode)

0~15

None

15

15

Cell

The setting of this parameter must meet the following condition: Read & "DLTHH2 Write "+ "DLHYST H2" < "DLTHH3 "+ "DLHYST H3".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "DLTHW Write B1" + "DLHYST WB1" < "DLTHW B2" + "DLHYST WB2".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "DLTHW Write B1" + "DLHYST WB1" < "DLTHW B2" + "DLHYST WB2".

N (No impact on Not the UE in involved idle mode)

0~63

dB

35

35

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~100

None

90

90

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid when "PWRCT RLSW" in the "SET GCELLP WRBASI C" command Read & is set to Write PWR2 and "DNPCEN " in the "SET GCELLB ASICPAR A" command is set to YES.

N (No impact on Not the UE in involved idle mode)

2~255

None

Cell

The setting of this parameter must meet the following conditions : Read & "DLLTFE Write RLOWTH "< "DLLTFE RTGT"; "DLLTFE RLOWTH "< "DLLTFE RUPTH".

N (No impact on Not the UE in involved idle mode)

2~255

None

The recommende d value is 8 when DTX is disabled. Cell The recommende d value is 14 when DTX is enabled.

The setting of this parameter must meet the following Read & condition: Write "LTFERL OWTH" < "DLLTFE RTGT" < "LTFERU PTH".

N (No impact on Not the UE in involved idle mode)

2~255

None

60

60

Cell

The setting of this parameter must meet the following conditions Read & : Write "DLLTFE RUPTH" > "DLLTFE RTGT"; "DLLTFE RUPTH"

N (No impact on Not the UE in involved idle mode)

2~255

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~30

dB

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

1~30

dB

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

1~100

None

100

100

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

Cell

This parameter is valid when "PWRCT RLSW" in the "SET GCELLP WRBASI C" command Read & is set to Write PWR2 and "DNPCEN " in the "SET GCELLB ASICPAR A" command is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "DLQLO WTHRED " >= "DLQHIG HTHRED" .

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "DLQLO WTHRED " >= "DLQHIG HTHRED" .

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid when "PWRCT RLSW" in the "SET GCELLP WRBASI C" command Read & is set to Write PWR2 and "DNPCEN " in the "SET GCELLB ASICPAR A" command is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~63

dB

10

10

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~70

None

55

55

Cell

This parameter is valid only when "BQHOE Read & N" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~70

None

60

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

55

55

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10

None

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

TCH:0~9 120, step:480; ms SDCCH:0 ~8930, step:470

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

0~63

dB

20

20

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. Read & The Write following condition must be met: "DLREXL EVHIGHT HRED" >= "DLREXL EVLOWT HRED".

N (No impact on Not the UE in involved idle mode)

0~63

dB

20

20

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. Read & The Write following condition must be met: "DLREXL EVHIGHT HRED" >= "DLREXL EVLOWT HRED".

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

0~10

None

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

TCH:0~9 120, step:480; ms SDCCH:0 ~8930, step:470

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

0~100

None

Cell

This parameter is valid only when Read & "PWRCT Write RLOPTIM IZEDEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~100

None

55

55

Cell

This parameter is valid only when Read & "PWRCT Write RLOPTIM IZEDEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~63

dB

45

45

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "DLSSHI GHTHRE D" >= "DLSSLO WTHRED ".

N (No impact on Not the UE in involved idle mode)

0~63

dB

28

28

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "DLSSHI GHTHRE D" >= "DLSSLO WTHRED ".

N (No impact on Not the UE in involved idle mode)

0~300

ms

140

140

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

12

12

Cell

The setting of this parameter must meet the following conditions : "DLTHF1" Read & < Write "DLTHF2" ; "DLTHF1" + "DLHYST F1" < "DLTHF2" + "DLHYST F2".

N (No impact on Not the UE in involved idle mode)

0~63

dB

17

17

Cell

The setting of this parameter must meet the following conditions : "DLTHF2" Read & < Write "DLTHF3" ; "DLTHF2" + "DLHYST F2" < "DLTHF3" + "DLHYST F3".

N (No impact on Not the UE in involved idle mode)

0~63

dB

25

25

Cell

The setting of this parameter must meet the following conditions : "DLTHF2" Read & < Write "DLTHF3" ; "DLTHF2" + "DLHYST F2" < "DLTHF3" + "DLHYST F3".

N (No impact on Not the UE in involved idle mode)

0~63

dB

23

23

Cell

The setting of this parameter must meet the following conditions : "DLTHH1 Read & "< Write "DLTHH2 "; "DLTHH1 "+ "DLHYST H1" < "DLTHH2 "+ "DLHYST H2".

N (No impact on Not the UE in involved idle mode)

0~63

dB

31

31

Cell

The setting of this parameter must meet the following conditions : "DLTHH2 Read & "< Write "DLTHH3 "; "DLTHH2 "+ "DLHYST H2" < "DLTHH3 "+ "DLHYST H3".

N (No impact on Not the UE in involved idle mode)

0~63

dB

63

63

Cell

The setting of this parameter must meet the following conditions : "DLTHH2 Read & "< Write "DLTHH3 "; "DLTHH2 "+ "DLHYST H2" < "DLTHH3 "+ "DLHYST H3".

N (No impact on Not the UE in involved idle mode)

0~63

dB

12

12

Cell

The setting of this parameter must meet the following conditions : "DLTHW Read & B1" < Write "DLTHW B2"; ["DLTHW B1" + "DLHYST WB1" < "DLTHW B2" + "DLHYST WB2".

N (No impact on Not the UE in involved idle mode)

0~63

dB

18

18

Cell

The setting of this parameter must meet the following conditions : "DLTHW Read & B1" < Write "DLTHW B2"; ["DLTHW B1" + "DLHYST WB1" < "DLTHW B2" + "DLHYST WB2".

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

The setting of this Read & parameter Write depends on "Board Type".

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

The setting of this Read & parameter Write depends on "Board Type".

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CS1, CS2, None CS3, CS4

CS2

CS2

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, MCS9

None

MCS6

MCS6

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MCS1, MCS2, MCS3, MCS4, MCS7, MCS8, DAS5, , DAS6, DAS7, DAS8, DAS9, DAS10, DAS11, DAS12

None

DAS6

DAS6

Cell

This parameter is valid Read & only when Write "EGPRS2 A" is set to YES.

N (No impact on Not the UE in involved idle mode)

MCS1, MCS2, MCS3, MCS4, MCS7, MCS8, DAS5, , DAS6, None DAS7, DAS8, DAS9, DAS10, DAS11, DAS12, UNFIXED

UNFIXED

UNFIXED

Cell

This parameter is valid Read & only when Write "EGPRS2 A" is set to YES.

N (No impact on Not the UE in involved idle mode)

CS1, CS2, CS3, None CS4, UNFIXED

UNFIXED

UNFIXED

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MCS1, MCS2, MCS3, MCS4, MCS5, None MCS6, MCS7, MCS8, MCS9, UNFIXED

UNFIXED

UNFIXED

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5000

ms

2400

2400

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

OPEN

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~25.5, step:0.1

dB

30

30

Cell

This parameter is valid only when Read & "PWRBC Write DALLOW D" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~16383( BIT14), 1~65535( None BIT16), 1~167772 15(BIT24)

None

None

SCCP

When the value of "SPDF" in "ADD Read & N7DPC" Write is set to DNF, this parameter is valid.

BSC6900

1~11 character None s

None

None

SCCP

None

Read & Write

Not involved

Not involved

0~31

None

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

STP, A, IUR_G, LB

None

None

None

SCCP

None

Read & Write

Not involved

Not involved

0~186

None

None

None

SCCP

None

Read & Write

Not involved

Not involved

0~182

None

None

None

BSC

DPX of Read & Iur-g type Write

N (No impact on Not the UE in involved idle mode)

0~128

dB

72

72

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

60

IP/HDLC:60

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

60

IP/HDLC:60

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

60

IP/HDLC:60

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

60

IP/HDLC:60

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

80

80

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~150

ms

80

80

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

10

10

BTS

This parameter is valid only when Read & "BAKPW Write RSAVME THOD" is set to BYPWR. This parameter is valid only when Read & "BAKPW Write RSAVME THOD" is set to BYPWR. This parameter is valid only when Read & "BAKPW Write RSAVME THOD" is set to BYPWR.

N (No impact on Not the UE in involved idle mode)

0~12

BTS

N (No impact on Not the UE in involved idle mode)

2~10

dB

BTS

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 1, 2, 4, 8, 16, 32, s 64

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INACTIV E, ACTIVE

None

INACTIVE

INACTIVE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

PPP link

None

Read & Write

Not involved

Not involved

0~31(PE Ua), 0~251(E1 None of POUc), 0~335(T1 of POUc)

None

None

MP link

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

48

48

SCTP link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

Ethernet port

None

Read & Write

Not involved

Not involved

0~63

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~3600

180

180

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0 to 21

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~21

None

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~21

None

None

None

BSC

This parameter is valid Read & only when Write "IDXTYPE " is set to BYCELL.

Cell

0~30

15

15

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

YES, NO None

NO

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~128 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255 0.0.0.0~2 55.255.25 None 5.255

None

None

IP route

None

Read & Write

Not involved

Not involved

None

None

Current BFD session

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

IP route

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

IP route

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

IP route

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

E1/T1 port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, None TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

E1/T1 port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

85

85

Cell

The value of DTLOAD THRED must be set when "REASSE N" in the Read & "SET Write GCELLB ASICPAR A" command is set to DIRECTR YEN.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~12

None

None

None

BTS

The setting of this Read & parameter Write depends on "Board Type".

N (No impact on Not the UE in involved idle mode)

1, 2, 3, 4, 5, 6, 7, 8, None 9, 10, 11, 12

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 1

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1, 255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23, 255 None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~53

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~53, 255 None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FULL, HALF

None

FULL

FULL

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~12

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~24

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~59

min

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~59

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~80

None

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

20

20

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

BTS

None

Read & Write

BTS

0~2047

None

None

None

BTS

None

Read & Write

BTS

0~15

None

None

None

BTS

None

Read & Write

BTS

10~3600

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

LEVEL0, LEVEL1, LEVEL2

None

LEVEL0

LEVEL0

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~8

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOTSUP PORT, DDIVERS None ITY, DPBT

NOTSUPPO NOTSUPPO Cell RT RT

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

BTS

None

Read & Write

Not involved

Not involved

ACTIVE, ACTIVES TANDBY, None SLAVE1, SLAVE2, UTRP

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~83

None

None

None

Channeliz ed optical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

16~19

None

None

None

BTS

None

Read & Write

BTS

E1, T1

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

IP path

When the value of "PATHCH K" in "ADD Read & IPPATH" Write is set to ENABLE D, this parameter is valid.

N (No impact on Not the UE in involved idle mode)

0~49

dB

Cell

A 3G neighbori ng cell can be added into the candidate cell queue when the following conditions are met: "INTERR ATOUTB SCHOEN " is set to Read & YES; "BET3GH Write OEN" is set to YES; the Ec/No of the 3G neighbori ng cell for a period of time is greater than the sun of "HOECN OTH3G" and "ECNOO

N (No impact on Not the UE in involved idle mode)

0~49

dB

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

1. For a 900/1800 MHz CoBCCH cell, it is recommende d that this parameter be set to Yes. 2. For a 1800 MHz cell in the dualband network, it is recommende d that this parameter be Cell set to Yes. For other cells in the dual-band network, it is recommende d that this parameter be set to No. 3. When the A5/4-7 encryption algorithm is used, it is recommende d that this parameter be

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~214748 None 3646

2147483646 2147483646 BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-11~203712-31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-11~203712-31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-11~203712-31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-0101~2050- None 12-31

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

Cell

This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & The Write following condition must be met: "EDBSTA TTIME" >= "EDBLAS TTIME".

N (No impact on Not the UE in involved idle mode)

1~255

Cell

This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & The Write following condition must be met: "EDBSTA TTIME" >= "EDBLAS TTIME".

N (No impact on Not the UE in involved idle mode)

0~11

None

10

10

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

None

Cell

This parameter is valid only when "GPRS" is Read & set to Write SupportA sInnPcu or SupportA sExtPcu.

Cell

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2 and "FRINGE HOEN" is Read & set to Write YES. The following condition must be met: "EDGEAD JSTATTI ME" >= "EDGEAD JLASTTI ME".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2 and "FRINGE HOEN" is Read & set to Write YES. The following condition must be met: "EDGEAD JSTATTI ME" >= "EDGEAD JLASTTI ME".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2 and "FRINGE Read & HOEN" is Write set to YES. The following condition must be met: "EDGEST AT" >= "EDGELA ST".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM1 and "FRINGE Read & HOEN" is Write set to YES. The following condition must be met: "EDGEST AT1" >= "EDGELA ST1".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2 and "FRINGE Read & HOEN" is Write set to YES. The following condition must be met: "EDGEST AT" >= "EDGELA ST".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM1 and "FRINGE Read & HOEN" is Write set to YES. The following condition must be met: "EDGEST AT1" >= "EDGELA ST1".

N (No impact on Not the UE in involved idle mode)

YES, NO None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

None

Cell

This parameter is valid only when Read & "GPRS" is Write set to SupportA sInnPcu.

N (No impact on Not the UE in involved idle mode)

0~31

None

16

16

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DATE, WEEK, None DATEWE EK

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~15

None

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

ERR_PF M_5E6, ERR_PF M_1E5, ERR_PF M_5E5, ERR_PF M_1E4, ERR_PF M_5E4, ERR_PF M_1E3, ERR_PF M_5E3

None

None

ERR_PFM_1 Board E5

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NoPriority , Priority4, Priority3, Priority2, None Priority1, Priority0, PriorityB, PriorityA

Priority4

Priority4

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~7

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~4094

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

JAN, FEB, MAR, APR, MAY, JUN, JUL, None AUG, SEP, OCT, NOV, DEC

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ENABLE D, None DISABLE D

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

A5/0, A5/1, A5/2, A5/3, A5/4, A5/5, A5/6, A5/7

None

A5/0-1&A5/10&A5/20&A5/30&A5/40&A5/50&A5/60&A5/7-0

A5/0-1&A5/10&A5/20&A5/30&A5/4Cell 0&A5/50&A5/60&A5/7-0

None

Read & Write

N (No impact on Not the UE in involved idle mode)

AUTO, PLAINTE XT, None ENCRYP TED

AUTO

AUTO

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

AUTO, PLAINTE XT, None ENCRYP TED

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

When the value of "OPMOD E" of "BLK ACIC" is Read & E1/T1 link BYCICRA Write NGE, the value of ENDCIC needs to be set.

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

PBCIC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31

None

None

None

BSC

The setting of this parameter must meet the following condition: When "EndMont hDSTPA" Read & and Write "StartMon thDSTPA" are set to the same value, "EndDay DSTPA" must be later than "StartDay DSTPA".

N (No impact on Not the UE in involved idle mode)

degree 99.0~40.0 Celsius (step: 0.1)

BTS

The value of this parameter must be greater Read & than Write "Heater Startup Temperat ure".

N (No impact on Not the UE in involved idle mode)

JAN, FEB, MAR, APR, MAY, JUN, JUL, None AUG, SEP, OCT, NOV, DEC

None

None

BSC

The setting of this parameter must meet the following condition: Read & "EndMont Write hDSTPA" is the same as or is later than "StartMon thDSTPA"

N (No impact on Not the UE in involved idle mode)

0, 2, 4, 6

None

None

None

BTS

None

Read & Write

BTS

00:00~23: None 59

None

None

BSC

When "BSCDyn SwitchTrx PAAllow" is set to YES, the Read & value of Write "EndTime TACloseT rxPA" must be set.

N (No impact on Not the UE in involved idle mode)

8~255

None

None

None

When the value of "OPMOD E" of "BLK ATERE1T Read & E1/T1 link 1" is Write BYCICRA NGE, the value of ENDTS needs to be set.

N (No impact on Not the UE in involved idle mode)

1~31, step:8

None

None

None

When the value of "OPMOD E" of "BLK AE1T1" is Read & E1/T1 link BYCICRA Write NGE, the value of ENDTS needs to be set.

N (No impact on Not the UE in involved idle mode)

1~31

None

None

None

BTS

None

Read & Write

BTS

DISABLE D, None ENABLE D

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE D, None ENABLE D

ENABLED

ENABLED

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

70

70

Cell

This parameter is valid only when "UTOOTR AFHOALL OW" is set to YES. The following condition Read & must be Write met: "ENSOVE RLDTHR SH" > "ENGOV ERLDTH RSH" > "ENLOW LDTHRS H".

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

Cell

OFF, ON None

ON

ON

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

20

20

Cell

This parameter is valid only when "UTOOTR AFHOALL OW" is set to YES. The following condition Read & must be Write met: "ENSOVE RLDTHR SH" > "ENGOV ERLDTH RSH" > "ENLOW LDTHRS H".

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

80

80

Cell

This parameter is valid only when "UTOOTR AFHOALL OW" is set to YES. The following condition Read & must be Write met: "ENSOVE RLDTHR SH" > "ENGOV ERLDTH RSH" > "ENLOW LDTHRS H".

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

M3UA_A SP, None M3UA_IP SP

None

None

SCCP

None

Read & Write

Not involved

Not involved

M3UA_S GP, M3UA_IP SP, None M3UA_S S7SP, M3UA_S P

None

None

SCCP

Negotiatio n with the peer Read & network Write element is required.

Not involved

Not involved

0~63

dB

63

63

Cell

This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentri Read & c_cell and Write "HOCTRL SWITCH" in "SET GCELLH OBASIC" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~429496 None 7295

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

O1E3_R5 E4, O5E4_R1 E4, O1E4_R5 E5, None O5E5_R1 E5, O1E5_R5 E6, O5E6_R1 E6

O5E4_R1E4 O5E4_R1E4 Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~7

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~7

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~4094

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

1~214748 None 3646

2147483646 2147483646 BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

500~6000 ms 0

3000

3000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HOUR, None MIN, SEC

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-1-1 00:00:00~ 2037-12- None 31 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

ONE_BY_ ONE, None PARALLE L

None

ONE_BY_O NE

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-1-1 00:00:00~ 2037-12- None 31 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00:00~ None 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00:00~ None 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1970-1-1 00:00:00~ 2538-12- None 31 23:59:59

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-11~203712-31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00:00~ None 23:59:59

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

LOGINEV ENT, MANAGE EVENT, None AUTHEV ENT, OTHERE VENT

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00:00~ None 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

SUN, MON, TUE, None WED, THU, FRI, SAT

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

FIRST, SECOND, THIRD, None FOURTH, LAST

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

0.02

None

None

If "Sensor Type of External Analog 1" is set to VOLTAG E, the unit of "Upper Limit of Signal Output of External Analog 1" is V; if Read & "Sensor Write Type of External Analog 1" is set to CURREN T, the unit of "Upper Limit of Signal Output of External Analog 1" is A. If "Sensor Type of External Analog 1" is set to VOLTAG E, the unit of "Lower Limit of Signal Output of External Analog 1" is V; if Read & "Sensor Write Type of External Analog 1" is set to CURREN T, the unit of "Lower Limit of Signal Output of External Analog 1" is A.

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

0.004

None

None

N (No impact on Not the UE in involved idle mode)

VOLTAG E, None CURREN T

CURRENT

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

100

None

None

If "Sensor Type of External Analog 1" is set to VOLTAG E, the unit of "Upper Limit of Measure ment Range of External Analog 1" Read & is V; if Write "Sensor Type of External Analog 1" is set to CURREN T, the unit of "Upper Limit of Measure ment Range of External Analog 1"

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

None

None

If "Sensor Type of External Analog 1" is set to VOLTAG E, the unit of "Lower Limit of Measure ment Range of External Analog 1" Read & is V; if Write "Sensor Type of External Analog 1" is set to CURREN T, the unit of "Lower Limit of Measure ment Range of External Analog 1" If "Sensor Type of External Analog 2" is set to VOLTAG E, the unit of "Upper Limit of Signal Output of External Analog 2" is V; if Read & "Sensor Write Type of External Analog 2" is set to CURREN T, the unit of "Upper Limit of Signal Output of External Analog 2" is A.

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

0.02

None

None

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

0.004

None

None

If "Sensor Type of External Analog 2" is set to VOLTAG E, the unit of "Lower Limit of Signal Output of External Analog 2" is V; if Read & "Sensor Write Type of External Analog 2" is set to CURREN T, the unit of "Lower Limit of Signal Output of External Analog 2" is A.

N (No impact on Not the UE in involved idle mode)

VOLTAG E, None CURREN T

CURRENT

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

100

None

None

1~9 character V or A s

None

None

If "Sensor Type of External Analog 2" is set to VOLTAG E, the unit of "Upper Limit of Measure ment Range of External Analog 2" is V; if "Sensor Type of External Analog 2" is set to CURREN T, the unit of "Upper Limit of Measure ment Range of External Analog 2" If "Sensor Type of External Analog 2" is set to VOLTAG E, the unit of "Lower Limit of Measure ment Range of External Analog 2" is V; if "Sensor Type of External Analog 2" is set to CURREN T, the unit of "Lower Limit of Measure ment Range of External Analog 2"

Read & Write

N (No impact on Not the UE in involved idle mode)

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

0.02

None

None

If "Sensor Type of External Analog 3" is set to VOLTAG E, the unit of "Upper Limit of Signal Output of External Analog 3" is V; if Read & "Sensor Write Type of External Analog 3" is set to CURREN T, the unit of "Upper Limit of Signal Output of External Analog 3" is A. If "Sensor Type of External Analog 3" is set to VOLTAG E, the unit of "Lower Limit of Signal Output of External Analog 3" is V; if Read & "Sensor Write Type of External Analog 3" is set to CURREN T, the unit of "Lower Limit of Signal Output of External Analog 3" is A.

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

0.004

None

None

N (No impact on Not the UE in involved idle mode)

VOLTAG E, None CURREN T

CURRENT

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

100

None

None

If "Sensor Type of External Analog 3" is set to VOLTAG E, the unit of "Upper Limit of Measure ment Range of External Analog 3" Read & is V; if Write "Sensor Type of External Analog 3" is set to CURREN T, the unit of "Upper Limit of Measure ment Range of External Analog 3"

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

None

None

If "Sensor Type of External Analog 3" is set to VOLTAG E, the unit of "Lower Limit of Measure ment Range of External Analog 3" Read & is V; if Write "Sensor Type of External Analog 3" is set to CURREN T, the unit of "Lower Limit of Measure ment Range of External Analog 3" If "Sensor Type of External Analog 4" is set to VOLTAG E, the unit of "Upper Limit of Signal Output of External Analog 4" is V; if Read & "Sensor Write Type of External Analog 4" is set to CURREN T, the unit of "Upper Limit of Signal Output of External Analog 4" is A.

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

0.02

None

None

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

0.004

None

None

If "Sensor Type of External Analog 4" is set to VOLTAG E, the unit of "Lower Limit of Signal Output of External Analog 4" is V; if Read & "Sensor Write Type of External Analog 4" is set to CURREN T, the unit of "Lower Limit of Signal Output of External Analog 4" is A.

N (No impact on Not the UE in involved idle mode)

VOLTAG E, None CURREN T

CURRENT

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character V or A s

100

None

None

1~9 character V or A s

None

None

If "Sensor Type of External Analog 4" is set to VOLTAG E, the unit of "Upper Limit of Measure ment Range of External Analog 4" is V; if "Sensor Type of External Analog 4" is set to CURREN T, the unit of "Upper Limit of Measure ment Range of External Analog 4" If "Sensor Type of External Analog 4" is set to VOLTAG E, the unit of "Lower Limit of Measure ment Range of External Analog 4" is V; if "Sensor Type of External Analog 4" is set to CURREN T, the unit of "Lower Limit of Measure ment Range of External Analog 4"

Read & Write

N (No impact on Not the UE in involved idle mode)

Read & Write

N (No impact on Not the UE in involved idle mode)

NoExclusi ve, None Exclusive

NoExclusive NoExclusive Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

None

25

Cell

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

This parameter is valid only when Read & "PWRBC Write DALLOW D" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

This parameter is valid only when Read & "PWRBC Write DALLOW D" is set to YES.

N (No impact on Not the UE in involved idle mode)

2048~504 None 7

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5048~804 None 7

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2048~504 None 7

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

Cell

None

Read & Write

Cell

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

EM0, EM1

None

EM0

EM0

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

60sec, 120sec, 240sec, 480sec, s 960sec, 1920sec, 3840sec, 7680sec

60sec

60sec

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TYPE1, TYPE2, TYPE3

None

TYPE1

TYPE1

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Normal_c ell, None DualTst_ ExtCell

Normal_cell

Normal_cell

Cell

None

Read & Write

Cell

SEND, NOTSEN None D

SEND

SEND

Cell

If "UPEXTT BFINACT DELAY" in the "SET GCELLP RIVATEO PTPARA" command is set to 0, "EXTUTB Read & FNODAT Write A" must be 0. If "UPEXTT BFINACT DELAY" is not set to 0, "EXTUTB FNODAT A" can be 0 or 1.

N (No impact on Not the UE in involved idle mode)

0~12750, ms step: 50

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PLUS_1, None MINUS_1

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

HIGH_SP EED, None LOW_SP EED

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

55~100

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

CONTINU OUS, DISCRET None E, DUTY_R ATIO

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NORMAL _FAN, None IND_FAN

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO_SPE ED_ADJU STMENT, HW_AUT O_TEMP ERATUR E_CONT None ROL, SPECIFY _RATE, SOFTWA RE_CON TROL

SOFTWARE SOFTWARE BSC6900 None _CONTROL _CONTROL

Read & Write

N (No impact on Not the UE in involved idle mode)

IND_FAN, NORMAL None _FAN

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

If this parameter is set to "YES", the following condition must be met: The setting of this parameter must meet the following condition: "FallBack Read & Write Start Time" > "Ring II Wait Time Before Switch" + "Ring II Try Rotating Duration Time". If this parameter is set to "NO", the following condition

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

55

75

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1999

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0~1999

None

PPP link

None

Read & Write

BSC6900

0~1999

None

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1999

None

This index can correspon d with any threshold (maximu m value of 80) in the six queues. The IP logical following Read & port condition Write must be met: threshold x 64 x 1024 x logical port bandwidth < 42949672 95(0xFFF

N (No impact on Not the UE in involved idle mode)

10~1999

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1999

None

Ethernet port

None

Read & Write

Not involved

Not involved

2~1999

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~62

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BTS

None

Read & Write

BTS

0~100

per cent

85

85

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

None, 16bit, 32bit

None

16bit

16bit

PPP link

None

Read & Write

PPP link

None, 16bit, 32bit

None

16bit

16bit

MP link

None

Read & Write

BSC6900

ON, OFF None

ON

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

43.2~57.5 V (step: 0.1)

535

535

BTS

The value of this parameter must be smaller than "Even charging voltage" Read & and at Write least two volts higher than "DC undervolt age alarm threshold" .

N (No impact on Not the UE in involved idle mode)

AUTO, MANU

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

AUTO, MANU

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~42, step: 6

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~36, Positive infinity, step: 6

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~16383

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~49

dB

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-20, -6, 18, -8, dB 16, -10, 14, -12

Cell

This parameter is valid only when the ""INTERR ATCELLR ESELEN" Read & " Write parameter regarding the "SET GCELLH OBASIC" command is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Negative infinity, dB 28~28, step: 4

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

RSCP, EcN0

None

RSCP

RSCP

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-114~-84, dBm step: 2

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~511

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~1000

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

For the doubletransceiver BTS and NGBTS, the default value Cell is NO; for other BTS, this parameter is invalid.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

per mill

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

per mill

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

per mill

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

per mill

16

16

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

per mill

32

32

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

per mill

64

64

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

per mill

128

128

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO_FH, BaseBan d_FH, None RF_FH, Hybrid_F H

NO_FH

NO_FH

Cell

None

Read & Write

Cell

1~128 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~200 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~200 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~128 character None s

None

None

BSC6900 None

Read & Write

Not involved

Not involved

txt, csv

None

csv

csv

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~32

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FALSE, TRUE

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

INACTIV E, ACTIVE

None

INACTIVE

INACTIVE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

80

80

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65534

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65534

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

ENABLE

ENABLE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

60~65534 s

900

900

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

60~65534 s

900

900

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FIX_16K_ ABIS, FLEX_AB None IS, SEMI_ABI S

FIX_16K_AB FIX_16K_AB BTS IS IS

None

Read & Write

BTS

OFF, ON None

OFF

When tight frequency reuse is used, the Cell recommende d value is ON.

This parameter is valid when "FHMOD E" in the Read & "SET Write GCELLH OPTP" command is not set to NO_FH.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

ms

4500

4500

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

ms

1000

1000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

ON

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

PPP link

None

Read & Write

BSC6900

OFF, ON None

ON

ON

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

Ethernet port

None

Read & Write

Not involved

Not involved

OFF, ON None

None

None

BTS

None

Read & Write

Not involved

Not involved

0~20

None

10

10

Cell

This parameter is valid only when "RXQCKF ALLHOE N" in "SET GCELLH OBASIC" is set to YES. The following condition must be met: Read & "FLTPAR Write AA1" + "FLTPAR AA2" + "FLTPAR AA3" + "FLTPAR AA4" + "FLTPAR AA5" + "FLTPAR AA6" + "FLTPAR AA7" + "FLTPAR AA8" = 80.

N (No impact on Not the UE in involved idle mode)

0~20

None

10

10

Cell

This parameter is valid only when "RXQCKF ALLHOE N" in "SET GCELLH OBASIC" is set to YES. The following condition must be met: Read & "FLTPAR Write AA1" + "FLTPAR AA2" + "FLTPAR AA3" + "FLTPAR AA4" + "FLTPAR AA5" + "FLTPAR AA6" + "FLTPAR AA7" + "FLTPAR AA8" = 80.

N (No impact on Not the UE in involved idle mode)

0~20

None

10

10

Cell

This parameter is valid only when "RXQCKF ALLHOE N" in "SET GCELLH OBASIC" is set to YES. The following condition must be met: Read & "FLTPAR Write AA1" + "FLTPAR AA2" + "FLTPAR AA3" + "FLTPAR AA4" + "FLTPAR AA5" + "FLTPAR AA6" + "FLTPAR AA7" + "FLTPAR AA8" = 80.

N (No impact on Not the UE in involved idle mode)

0~20

None

10

10

Cell

This parameter is valid only when "RXQCKF ALLHOE N" in "SET GCELLH OBASIC" is set to YES. The following condition must be met: Read & "FLTPAR Write AA1" + "FLTPAR AA2" + "FLTPAR AA3" + "FLTPAR AA4" + "FLTPAR AA5" + "FLTPAR AA6" + "FLTPAR AA7" + "FLTPAR AA8" = 80.

N (No impact on Not the UE in involved idle mode)

0~20

None

10

10

Cell

This parameter is valid only when "RXQCKF ALLHOE N" in "SET GCELLH OBASIC" is set to YES. The following condition must be met: Read & "FLTPAR Write AA1" + "FLTPAR AA2" + "FLTPAR AA3" + "FLTPAR AA4" + "FLTPAR AA5" + "FLTPAR AA6" + "FLTPAR AA7" + "FLTPAR AA8" = 80.

N (No impact on Not the UE in involved idle mode)

0~20

None

10

10

Cell

This parameter is valid only when "RXQCKF ALLHOE N" in "SET GCELLH OBASIC" is set to YES. The following condition must be met: Read & "FLTPAR Write AA1" + "FLTPAR AA2" + "FLTPAR AA3" + "FLTPAR AA4" + "FLTPAR AA5" + "FLTPAR AA6" + "FLTPAR AA7" + "FLTPAR AA8" = 80.

N (No impact on Not the UE in involved idle mode)

0~20

None

10

10

Cell

This parameter is valid only when "RXQCKF ALLHOE N" in "SET GCELLH OBASIC" is set to YES. The following condition must be met: Read & "FLTPAR Write AA1" + "FLTPAR AA2" + "FLTPAR AA3" + "FLTPAR AA4" + "FLTPAR AA5" + "FLTPAR AA6" + "FLTPAR AA7" + "FLTPAR AA8" = 80.

N (No impact on Not the UE in involved idle mode)

0~20

None

10

10

Cell

This parameter is valid only when "RXQCKF ALLHOE N" in "SET GCELLH OBASIC" is set to YES. The following condition must be met: Read & "FLTPAR Write AA1" + "FLTPAR AA2" + "FLTPAR AA3" + "FLTPAR AA4" + "FLTPAR AA5" + "FLTPAR AA6" + "FLTPAR AA7" + "FLTPAR AA8" = 80.

N (No impact on Not the UE in involved idle mode)

0~200

None

Cell

This parameter is valid only when "RXQCKF ALLHOE Read & N" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

OPEN

OPEN

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~19

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INDOOR, OUTDOO None R

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~128 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~100 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~128 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~128 character None s

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~100 character None s

None

none

BSC6900 None

Read & Write

Not involved

Not involved

1~256 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~256 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OPEN, CLOSE

None

OPEN

OPEN

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~300

15

15

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~30

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Close, Open

None

Close

Close

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

BTS

None

Read & Write

BTS

0~23

None

None

None

BTS

None

Read & Write

BTS

1~30

ms

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

128~1024 byte

256

None

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

2715647~ None 2715647

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ONTIME, RELATIV None E

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

ONTIME, DAILY_T, DAILY_C, WEEKLY _T, WEEKLY None _C, MONTHL Y_T, MONTHL Y_C

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1023

None

None

None

TRX

None

Read & Write

Cell

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

0~1023

None

None

None

Cell

None

Read & Write

Services are disrupted when the Cell BCCH frequency of a cell is changed.

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

36671

36671

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PGSM90 0, EGSML2 5, EGSM35 M, RGSML2 5, GSM900_ RGSM39 M, None DCS1800 , PCS1900, GSM850, EGSM24 M, DCS1800 _L, DCS1800 _H

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

25

25

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1023

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

LOOSE, TIGHT

None

LOOSE

LOOSE

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~800 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MainDiver sity, Maximum None MeanValu e

MaximumMe MaximumMe Cell anValue anValue

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

May_Use, Shall_Use , None Shall_NO T_Use

Shall_Use

Shall_Use

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

BTS

None

Read & Write

BTS

0~255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

BTS

TXT, CSV None

TXT

TXT

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~33

None

None

None

None

The factor table index is configure d by Read & setting Write the value of "FTI" in "ADD FACTOR TABLE". Read & Write

N (No impact on Not the UE in involved idle mode)

1~33

None

None

None

BSC6900 None

Not involved

Not involved

0~33

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~255

dB

20

20

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0~600

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0~255

dB

10

10

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0~600

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2. The Read & following Write condition must be met: "FULLTO HALFHO DURATIO N" >= "FULLTO HALFHO PERIOD".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2. The following Read & condition Write must be met: "FULLTO HALFHO STATTIM E" >= "FULLTO HALFHO LASTTIM E".

N (No impact on Not the UE in involved idle mode)

0~200000 kbit/s

BSC6900 None

Read & Write

Not involved

Not involved

0~200000 kbit/s

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

20

20

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

15

15

BSC6900 None

Read & Write

Not involved

Not involved

0~200000 kbit/s

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

BSC6900 None

Read & Write

Not involved

Not involved

0~200000 kbit/s

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

BSC6900 None

Read & Write

Not involved

Not involved

0~200000 kbit/s

BSC6900 None

Read & Write

Not involved

Not involved

-100~100 per cent

110

110

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

None

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

A0, U1

None

A0

A0

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

12

12

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

hour{0~2 3} None min{0~59}

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

None

40

40

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

ON

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

hour{0~2 3} None min{0~59}

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DEG, SEC

None

DEG

DEG

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~4, step: 1/8

bit

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, SupportA sInnPcu, None SupportA sExtPcu

NO

None

Cell

None

Read & Write

Cell

NO, SupportA sInnPcu, None SupportA sExtPcu

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0dB, 2dB, 4dB, 6dB, 8dB, dB 10dB, 12dB, 14dB

2dB

2dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

GPRS, EGPRSN ORCH, EGPRSP RICH, None EGPRSS PECH, NONGPR S

NONGPRS

NONGPRS

Physical channel

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DB110, DB108, DB106, DB104, DB102, DB100, DB98, DB96, DB94, DB92, DB90, DB88, DB86, DB84, DB82, DB80, DB78, dB DB76, DB74, DB72, DB70, DB68, DB66, DB64, DB62, DB60, DB58, DB56, DB54, DB52, DB50, DB48, no use

DB110

DB110

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10sec, 20sec, 30sec, 40sec, 50sec, 60sec, 70sec, 80sec, 90sec, 100sec, 110sec, 120sec, 130sec, 140sec, 150sec, 160sec, 170sec, 180sec, 190sec, 200sec, 210sec, 220sec, 230sec, 240sec, 250sec, 260sec, 270sec, 280sec, 290sec, 300sec, 310sec, 320sec, no use

10sec

10sec

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0db, 10db, 20db, 30db, 40db, dB 50db, 60db, infinity, no use

10db

10db

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

GPS, GLONAS S, None GPSGlon ass

GPS

GPS

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

10

10

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100000 None 000

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100000 None 000

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65534

None

None

None

BSC

None

Read & Write

BTS

1~20 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~512

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

Transmis sion None resource group Transmis sion None resource group

Read & Write

Not involved

Not involved

IP

None

None

None

Read & Write

Not involved

Not involved

LAC_CI, PLMN, LAC, CI

None

None

LAC_CI

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

80

80

BSC6900 None

Read & Write

Not involved

Not involved

1~15

None

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

Cell

This parameter is valid when Read & "MEASU Write RETYPE" is set to EnhMeas Report.

N (No impact on Not the UE in involved idle mode)

UNSUPP ORT, None SUPPOR T

SUPPORT

SUPPORT

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ECHORE PLY, UNREAC H, SOURCE QUENCH , REDIREC T, ECHO, ROUTER ADVERT, ROUTER SOLICIT, TIMXCEE None D, PARAMP ROB, TSTAMP, TSTAMP REPLY, IREQ, IREQREP LY, MASKRE Q, MASKRE PLY

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

255.255.255. 255.255.255. BTS 255 255

None

Read & Write

BTS

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

dB

20

20

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0~600

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2. The following Read & condition Write must be met: "HALFTO FULLHO STATTIM E" >= "HALFTO FULLHOL ASTTIME ".

N (No impact on Not the UE in involved idle mode)

0~255

dB

10

10

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2. The following Read & condition Write must be met: "HALFTO FULLHO STATTIM E" >= "HALFTO FULLHOL ASTTIME ".

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES dB

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~600 None 000

None

1000(applicat ion type is M3UA), SCTP link None 5000(applicat ion type is BBAP)

Read & Write

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~8, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2. Read & The Write following condition must be met: "HCSSTA TTIME" >= "HCSLAS TTIME".

N (No impact on Not the UE in involved idle mode)

0.5~8, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2. Read & The Write following condition must be met: "HCSSTA TTIME" >= "HCSLAS TTIME".

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DCS1800 , None PCS1900

DCS1800

DCS1800

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~14

None

Cell

This parameter is valid only when Read & "HIGHPRI Write USERQU ALFIRST" is set to YES.

N (No impact on Not the UE in involved idle mode)

YES, NO None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

UNSUPP ORT, None SUPPOR T

UNSUPPOR None T

Cell

This parameter is valid only when "GPRS" is set to SupportA Read & sInnPcu Write and "SUPPOR TDTM" is set to SUPPOR T.

N (No impact on Not the UE in involved idle mode)

SysOpt, OSubcell, None USubcell, NoPrefer

SysOpt

SysOpt

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYCELLN AME, None BYCGI

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HOALGO RITHM1, None HOALGO RITHM2

HOALGORIT HOALGORIT Cell HM1 HM1

The value of this parameter must be the same Read & as that of Write "HOCTRL SWITCH" in "SET GCELLH OBASIC".

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

When parameter ""Quick handover enable"" is configure d to "YES",the n parameter ""Handov er Direction Forecast Enable"" can be Read & configure Write d to "YES".Fur thermore, before open "Handove r Direction Forecast Enable", parameter ""Chain Neighbou r Cell Type"" of cell should be

N (No impact on Not the UE in involved idle mode)

0~16

None

Cell

"Handove r Direction Forecast Statistic Times" >= Read & "Handove Write r Direction Forecast Last Times"

N (No impact on Not the UE in involved idle mode)

0~16

None

Cell

"Handove r Direction Forecast Statistic Times" >= Read & "Handove Write r Direction Forecast Last Times"

N (No impact on Not the UE in involved idle mode)

0~63

dB

50

50

Cell

This parameter is valid only when "QUICKH Read & OEN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "BET3GH OEN" is set to YES. The Read & following Write condition must be met: "HOSTAT 3G" >= "HODUR T3G".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "BET3GH OEN" is set to YES. The following Read & condition Write must be met: "HOSTAT 3GTDD" >= "HODUR T3GTDD" .

N (No impact on Not the UE in involved idle mode)

0~49

dB

35

35

Cell

This parameter is valid only when the following conditions are met: 1. The ""INTERR ATOUTB SCHOEN "" regarding the "SET GCELLH OBASIC" Read & command Write is set to YES. 2. The ""BET3G HOEN"" parameter is set to YES. 3. The ""FDDRE P"" parameter regarding the "SET GCELLC CUTRAN This parameter is valid only when "QUICKH OEN" in "SET GCELLH OBASIC" is set to Read & YES. The Write following condition must be met: "HOSTAT ICTIME" >= "HOLAST TIME".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

N (No impact on Not the UE in involved idle mode)

FREE, INCELL, OUTCEL L, None OUTST, OUTBSC, OUTSYS, SPCELL

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~127

dB

68

68

Cell

This parameter is valid only when "QUICKH Read & OEN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~61

dB

32

32

Cell

This parameter is valid only when "LOWRX Read & LEVOLF Write ORBIDS WITCH" is set to ON.

N (No impact on Not the UE in involved idle mode)

Pre_2G_ Cell, Pre_3G_ None Cell, Pre_2G_ CellThres

Pre_2G_Cell Pre_2G_Cell Cell Thres Thres

This parameter is valid only when the ""INTERR ATOUTB SCHOEN Read & "" Write parameter regarding the "SET GCELLH OBASIC" command is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

Cell

None

Read & Write

Not involved

Not involved

0~63

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BaseBan d_FH, None RF_FH

None

None

Cell

None

Read & Write

Cell

NO, YES, None NONE

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

25

25

Cell

This parameter is valid only when Read & "HOOPTS Write EL" is set to Pre_2G_ CellThres.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

Cell

None

Read & Write

Cell

0~23

None

None

None

Cell

None

Read & Write

Not involved

Not involved

NO_FH, BaseBan None d_FH, RF_FH

NO_FH

NO_FH

TRX

This parameter depends on "FHMOD E" in "SET GCELLH OPTP". This parameter can be set to BaseBan d_FH only when "FHMOD Read & E" is set Write to BaseBan d_FH or Hybrid_F H. This parameter can be set to RF_FH only when "FHMOD E" is set to RF_FH or Hybrid_F H.

If traffic handover fails after the modificati on of the Cell parameter , the service is interrupte d.

0~63

dB

63

63

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

15

15

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

50

50

Cell

This parameter is valid only when the following conditions are met: 1. The ""INTERR ATOUTB SCHOEN "" regarding the "SET GCELLH OBASIC" Read & command Write is set to YES. 2. The ""BET3G HOEN"" parameter is set to YES. 3. The ""FDDRE P"" parameter regarding the "SET GCELLC CUTRAN

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

10

10

Cell

This parameter is valid only when "INTERR ATOUTB SCHOEN " is set to YES and "BET3GH Read & OEN" is Write set to YES. The following condition must be met: "HOSTAT 3G" >= "HODUR T3G".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

10

10

Cell

This parameter is valid only when "INTERR ATOUTB SCHOEN " is set to YES and "BET3GH OEN" is Read & set to Write YES. The following condition must be met: "HOSTAT 3GTDD" >= "HODUR T3GTDD" .

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "QUICKH OEN" in "SET GCELLH OBASIC" is set to Read & YES. The Write following condition must be met: "HOSTAT ICTIME" >= "HOLAST TIME".

N (No impact on Not the UE in involved idle mode)

SINGLEH OST, PRIMHO None ST, SLAVEH OST

SINGLEHOS SINGLEHOS SCCP T T

None

Read & Write

BSC6900

SINGLEH OST, PRIMHO None ST, SLAVEH OST

SINGLEHOS SINGLEHOS BTS T T

When the BTS or cell is activated,t he host type of OPC must be single or primary if the host Read & type of Write BTS is single. Otherwise , the host type of OPC must be consistent with that of the

BTS

0~63

dB

25

25

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

50

50

Cell

This parameter is valid only when "QUICKH Read & OEN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO_HPA NT, YES_HPA None NT, NONE

NONE

NONE

Cell

None

Read & Write

Cell

NO_HPA NT, None YES_HPA NT

None

None

Cell

None

Read & Write

Cell

0~5

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~14

None

Cell

This parameter is valid only when Read & "GRADEA Write CCALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

35.0~55.6 V (step: 0.1)

440

440

BTS

The value of this parameter must be smaller Read & than "DC Write Undervolt age Alarm Threshold ".

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

May_Use, Shall_Use , None Shall_NO T_Use

Shall_Use

Shall_Use

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

Cell

None

Read & Write

Cell

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

This parameter is valid when "FHMOD E" in the Read & "SET Write GCELLH OPTP" command is not set to NO_FH.

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SBFD, MBFD

None

None

None

Current BFD session

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-99~70

degree Celsius

40

40

BTS

The value of this parameter must be greater Read & than "Low Write Temperat ure Critical Point".

N (No impact on Not the UE in involved idle mode)

0~30

degree Celsius

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

ENABLE

ENABLE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

OPEN

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character per cent s

80

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character per cent s

10

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0~100.0 None (step: 0.1)

1000

If "Power System Type" is "SC48200", the recommende d value is BTS "900". For other types of Power System, the recommende d value is "1000".

The value of this parameter must be greater Read & than Write "Lower Threshold of Humidity Alarm".

N (No impact on Not the UE in involved idle mode)

0.0~100.0 None (step: 0.1)

800

800

BTS

The value of this parameter must be greater Read & than Write "Lower Threshold of Humidity Alarm".

N (No impact on Not the UE in involved idle mode)

0.0~100.0 None (step: 0.1)

If "Power System Type" is "SC48200", the recommende d value is BTS "100". For other types of Power System, the recommende d value is "0".

The value of this parameter must be smaller Read & than Write "Upper Threshold of Humidity Alarm".

N (No impact on Not the UE in involved idle mode)

0.0~100.0 None (step: 0.1)

100

100

BTS

The value of this parameter must be smaller Read & than Write "Upper Threshold of Humidity Alarm".

N (No impact on Not the UE in involved idle mode)

1~30

min

15

15

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

180~1260 s

720

720

SCCP

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

E1PORT0 , E1PORT1 , E1PORT2 , None E1PORT3 , OPTICAL PORT0, OPTICAL PORT1

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MAINDO MU, SLAVED None OMU1, SLAVED OMU2

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

60~600

90

90

SCCP

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

dB

Cell

This parameter is valid only when Read & "IBCASO Write FTBLKS WITCH" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~23

dB

10

10

Cell

This parameter is valid only when Read & "IBCASO Write FTBLKS WITCH" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, s Step: 0.5

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~1920, step:480; ms SDCCH:4 70~1880, step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~14

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~14

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

Set this parameter to YES for the neighboring cell with cochannel interference and the neighboring Cell cell that may cause interference; set this parameter to NO for other neighboring cells.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, s Step: 0.5

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

dB

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, s Step: 0.5

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

dB

13

13

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

dB

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~600

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~22

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~22

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~40

None

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~30

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, s Step: 0.5

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~16

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~600

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~50

dB

15

It is recommende d that you set the path loss offset of layer 1 neighboring Cell cells of the serving cell to 15 dB and that of other neighboring cells to 25 dB.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~160

dB

110

110

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, UNDER, INNER, YES

None

UNDER

UNDER

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES, None NULL

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

ENABLE

For SingleRAN BTS, the recommende d value is "ENABLE". BTS For other types of BTS, the recommende d value is "DISABLE".

None

Read & Write

N (No impact on Not the UE in involved idle mode)

44~1024

byte

64

64

IP path

When the value of "PATHCH K" in "ADD Read & IPPATH" Write is set to ENABLE D, this parameter is valid.

N (No impact on Not the UE in involved idle mode)

0~63

None

22

22

BSC

None

Read & Write

Not involved

Not involved

0~63

None

20

20

BSC

None

Read & Write

Not involved

Not involved

0~63

None

18

18

BSC

None

Read & Write

Not involved

Not involved

1~30

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~30, 100~3276 None 7

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

84

84

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

Cell

This parameter is one of the conditions for the dynamic conversio n of the TCHF to the SDCCH. In addition to the condition Read & that the number of Write idle SDCCHs should be smaller than or equal to "IDLESDT HRES", the following three conditions must be met to trigger the conversio

N (No impact on Not the UE in involved idle mode)

BYIDX, None BYNAME

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

BSC6900 None

Read & Write

Not involved

Not involved

BYNAME, None BYID

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, BYID, None BYCGI

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

Cell

None

Read & Write

Not involved

Not involved

BYNAME, None BYID

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BSC

None

Read & Write

Not involved

Not involved

BYTLLI, BYIMSI

None

None

None

Subsyste None m

Read & Write

Not involved

Not involved

BYCELL, None BYBSC

None

None

BSC

None

Read & Write

Not involved

Not involved

YES, NO None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

IP route

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Positive, Minus

None

Positive

Positive

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~125

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~32

None

Cell

This parameter is valid only when "QUICKH Read & OEN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~15 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~300 ms 00

5000

5000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

Cell

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

ms

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~5

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

0~255

bit

Cell

This parameter is valid only when Read & "IMMASS Write TAALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~15 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~15 character None s

None

None

This parameter is valid Subsyste Read & only when m Write "IDXTYPE " is set to BYIMSI.

Not involved

Not involved

500~6000 ms 0

10000

10000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~8

bit

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~30

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~360

degree

360

360

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BTS

None

Read & Write

BTS

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM1 and "INTRAC Read & ELLFHH Write OEN" is set to YES. The following condition must be met: "INFHHO STAT" >= "INFHHO LAST".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

10

10

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM1 and "INTRAC Read & ELLFHH Write OEN" is set to YES. The following condition must be met: "INFHHO STAT" >= "INFHHO LAST".

N (No impact on Not the UE in involved idle mode)

CELLCAP CLASS, None NACCRE LATED

CELLCAPCL CELLCAPCL BSC ASS ASS

Set when Allow Info Read & Exchange Write at Iur-g is set to Yes

Not involved

CLOSE, OPEN

None

OPEN

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~39

None

25

25

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM1 and "INTRAC ELLFHH OEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~39

None

12

12

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM1 and "INTRAC ELLFHH OEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~50

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, None TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

1~255

10

10

Cell

This parameter is valid only when Read & "INNLOA Write DHOEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

This parameter is valid only when Read & "INNLOA Write DHOEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

90

90

Cell

This parameter is valid only when Read & "OUTLOA Write DHOENA BLE" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

BSC

None

Read & Write

Not involved

Not involved

0~23

None

None

None

BTS

None

Read & Write

BTS

0~15

None

None

None

BTS

None

Read & Write

BTS

Degree, D_min_se None c

Degree

Degree

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when "SIGCHA Read & NHOEN" Write in "SET GCELLH OBASIC" is set to YES. None Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

BSC

Not involved

Not involved

0~23

None

None

None

BTS

None

Read & Write

BTS

0~11

None

None

None

BSC

None

Read & Write

Not involved

Not involved

0~254

None

None

None

BTS

None

Read & Write

BTS

2~3600

None

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~127

dB

67

67

Cell

Inter-layer HO threshold of the serving cell = "Interlayer HO threshold" - "Interlayer HO Hysteresi s". Inter-layer HO threshold Read & of the neighbori Write ng cell = "Interlayer HO threshold" + "Adjacent Cell Interlayer HO Hysteresi s" - 64. The value of "Interlayer HO threshold" can be set

N (No impact on Not the UE in involved idle mode)

INTBANI, None INTBANII

INTBANII

INTBANII

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~127

dB

68

In densely populated urban areas, the recommende Cell d value is 68; in the suburbs, the recommende d value is 72.

When "Current HO Control Algorithm" in "SET GCELLH OBASIC" is set to HOALGO RITHM1( Handover algorithm I), "Intercell HO Hysteresi s" should Read & Write be set within the range of 64127.Whe n "Current HO Control Algorithm" in "SET GCELLH OBASIC" is set to HOALGO RITHM2( Handover algorithm

N (No impact on Not the UE in involved idle mode)

0~255

15

15

Cell

This parameter is valid only when "HOCTRL SWITCH" Read & in "SET Write GCELLH OBASIC" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0.5~8, step:0.5

Cell

This parameter is valid only when "INTERF HOEN" is set to YES and "HOCTRL SWITCH" is set to HOALGO Read & RITHM2. Write The following condition must be met: "INTERF ERESTA TTIME" >= "INTERF ERELAST TIME".

N (No impact on Not the UE in involved idle mode)

0.5~8, step:0.5

Cell

This parameter is valid only when "INTERF HOEN" is set to YES and "HOCTRL SWITCH" is set to HOALGO Read & RITHM2. Write The following condition must be met: "INTERF ERESTA TTIME" >= "INTERF ERELAST TIME".

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

48~115

None

110

110

Cell

The setting of this parameter must meet the Read & following Write condition: "INTERFT HRES0" > "INTERFT HRES1".

N (No impact on Not the UE in involved idle mode)

48~115

None

105

105

Cell

The setting of this parameter must meet the Read & following Write condition: "INTERFT HRES1" > "INTERFT HRES2".

N (No impact on Not the UE in involved idle mode)

48~115

None

98

98

Cell

The setting of this parameter must meet the Read & following Write condition: "INTERFT HRES2" > "INTERFT HRES3".

N (No impact on Not the UE in involved idle mode)

48~115

None

92

92

Cell

The setting of this parameter must meet the Read & following Write condition: "INTERFT HRES3" > "INTERFT HRES4".

N (No impact on Not the UE in involved idle mode)

48~115

None

87

87

Cell

The setting of this parameter must meet the Read & following Write condition: "INTERFT HRES4" > "INTERFT HRES5".

N (No impact on Not the UE in involved idle mode)

48~115

None

85

85

Cell

The setting of this parameter must meet the Read & following Write condition: "INTERFT HRES4" > "INTERFT HRES5".

N (No impact on Not the UE in involved idle mode)

0~60

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

480~1488 0, step: ms 480

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~100

None

80

80

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

When "InterRAT In BSC Handover Read & Enable" is Write set to NO, this parameter must be set to NO.

Not involved

Not involved

1~49

dB

20

20

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~49

dB

49

49

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~49

dB

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~91

dB

60

60

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~91

dB

91

91

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~91

dB

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

{0~4}

None

OFF

OFF

BSC

This parameter is valid only when the ""INTERR ATOUTB SCHOEN Read & "" Write parameter regarding the "SET GCELLH OBASIC" command is set to YES.

N (No impact on Not the UE in involved idle mode)

1~240

72

72

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

BSC6900 None

Read & Write

Ethernet port

0~31

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

500~6000 ms 0

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

500~6000 ms 0

10000

10000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM1 and "INTRAC ELLHOE N" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

In the hotspot areas, densely populated urban areas, urban areas, suburbs, and rural areas, Cell the recommende d value is YES; in the high-speed circumstance s, the recommende d value is

None

Read & Write

N (No impact on Not the UE in involved idle mode)

500~6000 ms 0

10000

10000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~49

dB

25

25

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~91

dB

30

30

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

BTS

None

Read & Write

BTS

1~1440

min

30

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~1024

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

NSE

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

NSE

None

Read & Write

NSE

0.0.0.0~2 55.255.25 None 5.255

255.255.255. 255.255.255. BTS 255 255

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

IP path

The "IPADDR" in "ADD IPPATH" can not be at one network segment with the peer IP address of SCTPLN K or IPPATH whose Read & local IP address is Write device IP address of FG2/GOU in this subrack;"I PADDR" and "PEERIP ADDR" in "ADD IPPATH" must be at one network segment;(

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255 0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

Not involved

Not involved

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

The setting of this parameter cannot be Read & duplicate Write with "Slave Clock Server IP Address".

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

The value of this parameter cannot be the same Read & as Write "Master Clock Server IP Address".

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

10

10

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

No_HC, UDP/IP_ HC, None RTP/UDP /IP_HC

UDP/IP_HC

UDP/IP_HC

PPP link

None

Read & Write

BSC6900

No_HC, UDP/IP_ HC, None RTP/UDP /IP_HC

UDP/IP_HC

UDP/IP_HC

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0~5

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0~12999

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

IP_OVER _FE/GE, None IP_OVER _E1

IP_OVER_F IP_OVER_F BTS E/GE E/GE

This parameter is valid only when Read & "SERVIC Write EMODE" in "MOD BTS" is set to IP.

BTS

IP_OVER _FE/GE, None IP_OVER _E1

None

None

BTS

None

Read & Write

BTS

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

NO

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

UNSUPP ORT, None SUPPOR T

None

None

BTS

If the redundan cy configurat ion mode is not supported , only one Read & clock Write server can be configure d. Otherwise , two clock servers can be

N (No impact on Not the UE in involved idle mode)

UNSUPP ORT, None SUPPOR T

None

None

BTS

If the redundan cy configurat ion mode is not supported , only one Read & clock Write server can be configure d. Otherwise , two clock servers can be

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

BTS

YES, NO None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

Transmis sion None resource group

Read & Write

Not involved

Not involved

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

TRX

None

Read & Write

Cell

NO, YES None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

STATIC, None DYNAMIC

None

None

NSE

None

Read & Write

Not involved

Not involved

NO, YES None

None

None

IP Path

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

YES, NO None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

This parameter can be set to YES only when "BssLsGe nMode" in Read & "SET Write BSSLS" is set to BTSPRIO RITY, BSCPRIO RITY, or BTSONL Y.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

YES, NO None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOT_CO NFIG, None CONFIG

NOT_CONFI NOT_CONFI BTS G G

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~30

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TRUE, FALSE

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

65535

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ABIS, A, ATER, IUR_G

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

PPP, MP None

None

None

IP route

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OVERLAI D, UNDERL None AID, NONE

NONE

NONE

TRX

This parameter is valid only when "IUOTP" Read & in "MOD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

CONVER T0, CONVER T1, None CONVER T2, CONVER T3

CONVERT0 CONVERT0 Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

The following condition must be met: Read & "IUOHOS Write TATIME" >= "IUOHOD URATIME ".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

10

10

Cell

The following condition must be met: Read & "IUOHOS Write TATIME" >= "IUOHOD URATIME ".

N (No impact on Not the UE in involved idle mode)

Normal_c ell, Concentri None c_cell, EDB_cell

Normal_cell

Normal_cell

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

OFF

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Hexadeci mal, None Character _String

Character_St Character_St None ring ring

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~124 character None s

None

SBS 155

Board

None

Read & Write

BSC6900

0~124 character None s

None

SBS 155

Board

None

Read & Write

BSC6900

NULL, 1byte, 16byte, 64byte

None

None

16byte

Board

None

Read & Write

BSC6900

OFF, ON None

None

OFF

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Hexadeci mal, none Character _String

Character_St Character_St None ring ring

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~124 character None s

None

SBS 155

Board

None

Read & Write

BSC6900

0~124 character None s

None

SBS 155

Board

None

Read & Write

BSC6900

NULL, 1byte, 16byte, 64byte

None

None

16byte

Board

None

Read & Write

BSC6900

OFF, ON None

None

OFF

Channeliz ed optical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

Hexadeci mal, None Character _String

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NULL, 1BYTE, None 16BYTE, 64BYTE

None

None

Channeliz ed optical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64 character None s

None

None

Channeliz ed optical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

ZERO, SPACE

None

None

SPACE

Board

None

Read & Write

Optical port

DISABLE, None ENABLE

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255, ms (step: 20)

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DENY, ALLOW

None

DENY

When the disorder phenomenon is severe in the IP network, the recommende d value is ALLOW; when there is no or little BSC disordered packets, you are recommende d to set this parameter to DENY to avoid extra transmission delay.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOTINDICAT E-END, None INDICAT E-END

None

None

MSP protect group

None

Read & Write

BSC6900

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~30

PPP link

None

Read & Write

BSC6900

1~65533, None 65535

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65533, None 65535

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

STATIC_ LACP, MANUAL None _AGGRE GATION

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

1~5 character degree s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~90

degree

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~90

degree

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~59

minute

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~9

second

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~59

second

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-90~90, step: degree 0.000001 90:00:00. SEC 000~90:0 0:00.000

None

None

None

None

Read & Write

Not involved

Not involved

None

None

None

None

Read & Write

Not involved

Not involved

100~1000 0, ms step:100

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10000

ms

25

25

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

1, 2, 3, 4

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1, 2, 3, 4

None

Cell

There are four network layers, that is, layer 1 to layer 4. A lower layer No. indicates a higher Read & priority. Write The cell priority is determine d by both the network layer and the "PRIOR" parameter .

N (No impact on Not the UE in involved idle mode)

0~100

None

Cell

The parameter is independ ent of "Load Read & Handover Write Support" and " Enhanced Load HO Allowed".

N (No impact on Not the UE in involved idle mode)

0~300

20

20

BSC

Lb Congestio n Protection Timer Read & 1<Lb Write Congestio n Protection Timer 2

N (No impact on Not the UE in involved idle mode)

0~300

30

30

BSC

Lb Congestio n Protection Timer Read & 1<Lb Write Congestio n Protection Timer 2

N (No impact on Not the UE in involved idle mode)

CLOSE, PSDOWN , AMRC, None CSPH, CSFHHO

CSFHHO

CSFHHO

BSC

CLOSE, PSDOWN , AMRC, None CSPH, CSFHHO

PSDOWN

PSDOWN

BSC

If this parameter is not set to CLOSE, it value must not be the same as "LDRSND ", "LDRTRD ", or "LDRFST ". If this parameter is not set to CLOSE, it value must not be the same as "LDRSND ", "LDRTRD ", or "LDRFOU H".

Read & Write

N (No impact on Not the UE in involved idle mode)

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, PSDOWN , AMRC, None CSPH, CSFHHO

AMRC

AMRC

BSC

If this parameter is not set to CLOSE, it value must not Read & be the Write same as "LDRFST ", "LDRTRD ", or "LDRFOU H".

N (No impact on Not the UE in involved idle mode)

0~186

None

None

None

SCCP

None

Read & Write

Not involved

Not involved

CRITICAL , MAJOR, None MINOR

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

INFO, WARN, ERR, AST

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

None

ON

BSC6900 None

Read & Write

Not involved

Not involved

0~7

None

Ethernet port

None

Read & Write

Not involved

Not involved

NO, YES, None NONE

YES

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM1.

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM1 and "LEVHOE Read & N" is set Write to YES. The following condition must be met: "LEVSTA T" >= "LEVLAS T".

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM1 and "LEVHOE Read & N" is set Write to YES. The following condition must be met: "LEVSTA T" >= "LEVLAS T".

N (No impact on Not the UE in involved idle mode)

OAM, TDM_Swit ching, GCP, RGCP, MCP, GTC, GPCU, IP, FR, HDLC, None TDM, GbIP, Abis_TD M, Ater_TDM , Pb_TDM, A_TDM, Abis_IP, SAU

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TDM_Swit ching, GCP, RGCP, MCP, GTC, GPCU, IP, FR, HDLC, None TDM, GbIP, Abis_TD M, Ater_TDM , Pb_TDM, A_TDM, Abis_IP

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

IP, Abis_IP

None

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

A/Gb, Abis/Ater/ None Pb/Gb

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5120~537 None 5

None

None

None

None

Read & Write

Not involved

Not involved

0~99

None

10

10

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

90~99

per cent

90

90

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

70~95

per cent

70

70

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~17407

None

None

None

LAPDLNK None

Read & Write

Not involved

Not involved

DIFFERE None NCE, ALL

DIFFERENC DIFFERENC None E E

None

Read & Write

N (No impact on Not the UE in involved idle mode)

64K, 2M

bit/s

64K

64K

MTP3 link None

Read & Write

Not involved

Not involved

0~9 character None s

10

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~8 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, None TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~40

35

35

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

40~80

45

45

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

LUCENT_ MODE, HUAWEI None _MODE, ALCATEL _MODE

None

None

Board

None

Read & Write

BSC6900

8K, 16K, 32K, 64K, None 2M

None

None

BSC

None

Read & Write

Not involved

Not involved

M3UA_M ASTER_ MOD, None M3UA_SL AVE_MO D

M3UA_MAS M3UA_MAS BSC6900 None TER_MOD TER_MOD

Read & Write

Not involved

Not involved

B0000, B0001, B0010, B0011, B0100, B0101, B0110, B0111, B1000, B1001, B1010, B1011, B1100, B1101, B1110, B1111

None

B1111

B1111

SCCP

None

Read & Write

N (No impact on Not the UE in involved idle mode)

B0000, B0001, B0010, B0011, B0100, B0101, B0110, B0111, B1000, B1001, B1010, B1011, B1100, B1101, B1110, B1111

None

B1111

B1111

SCCP

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

80

80

Cell

When the cell is a 2G external cell, this parameter is valid only when the "" OutBscLo adHoEn"" parameter regarding the "SET GCELLH OAD" command Read & Write is set to YES. When the cell is a 3G external cell, this parameter is valid only when either of the following conditions is met: 1. The ""INTERR

N (No impact on Not the UE in involved idle mode)

RANDOM ALG, None OTHERA LG

RANDOMAL RANDOMAL MSC G G

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

None

100

100

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter can be set only when Read & "Load Write Handover Support" is set to Yes.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-64dB ~ 63dB

None

Cell

The parameter value cannot be larger than the value of "PBGT HO Threshold Read & ". The Write parameter takes effect only when "Enhance d Load HO Allowed" is enabled.

N (No impact on Not the UE in involved idle mode)

0~255

10

10

Cell

This parameter is valid only when "HOCTRL SWITCH" Read & in "SET Write GCELLH OBASIC" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0~63

dB

63

63

Cell

This parameter is valid only when "HOCTRL SWITCH" Read & in "SET Write GCELLH OBASIC" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

1~255

10

10

Cell

This parameter is valid only when "LOADHO Read & EN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~63

dB

Cell

This parameter is valid only when "LOADHO EN" in "SET GCELLH OBASIC" Read & is set to Write YES. The value of this parameter must be smaller than "LOADOF FSET".

N (No impact on Not the UE in involved idle mode)

1~16

None

Cell

The parameter takes effect only when the Read & enhanced Write load handover algorithm is enabled.

N (No impact on Not the UE in involved idle mode)

0~63

dB

25

25

Cell

This parameter is valid only when "LOADHO Read & EN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FORBID, None PERMIT

PERMIT

PERMIT

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

60

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

85

85

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOTSTA DYNPDC H, DYNPDC None HASOCC UPY, DYNPDC HASIDLE

DYNPDCHA DYNPDCHA Cell SIDLE SIDLE

The parameter is independ ent of "Load Read & Handover Write Support" and "Enhance d Load HO Allowed".

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65534

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

The IP address must be in the Read & same network Write segment as "Peer IP address". The IP address must be in the Read & same network Write segment as "Peer IP address". None Read & Write

BTS

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

BTS

0~1023

None

None

None

NSE

Not involved

Not involved

0~1

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~35

None

None

None

BTS

None

Read & Write

Not involved

Not involved

0~35

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~200 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

SCTP link None

Read & Write

SCTP link

0.0.0.0~2 55.255.25 None 5.255

None

None

SCTP link None

Read & Write

SCTP link

OFF, ON None

ON

OFF

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1024~655 None 35

None

None

When the value of "MODE" in "ADD SCTPLN Read & SCTP link K" is set Write to Client, this parameter can be modified.

SCTP link

LFB, CL

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

NORMM ODE, RAPMOD ENOSER None V, RAPMOD ERESSE RV

NORMMOD E

NORMMOD E

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

90

95

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

90

80

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

This parameter determine s whether "LOGPO RTSN" Read & SCTP link and Write "LOGPO RTNO" in "ADD SCTPLN K" are When the value of "LOGPO RTFLAG" in "ADD Read & SCTP link SCTPLN Write K" is set to ON, this parameter is valid.

N (No impact on Not the UE in involved idle mode)

0~988

None

None

None

SCTP link

0~5, 8~27 None

None

None

When the value of "LOGPO RTFLAG" in "ADD Read & SCTP link SCTPLN Write K" is set to ON, this parameter is valid.

SCTP link

30~100

per cent

80

85

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

80

70

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

ON

ON

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PFM_RE SULT, HOST_P FM_RES ULT, ACTIVE_ DEF_ME AS_FILE, STANDB Y_DEF_M EAS_FIL E, PFM_SWI TCHS, HISTORY _ALARM, HISTORY None _FAULT, ALM_SYS TEM_CF G, SECURIT Y_LOG, OPT_LO G, OMU_LO G, BSC_CF G_MML, CELL_BA SIC_INF O, BSC_SE RIES_NO

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

COMLOG , None CMPLOG

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~5 character degree s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~180

degree

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~180

degree

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~59

minute

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~9

second

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~59

second

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-180~180, step: degree 0.000001 180:00:00 SEC .000~180: 00:00.000

None

None

None

None

Read & Write

Not involved

Not involved

None

None

None

None

Read & Write

Not involved

Not involved

1~3

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYLOCAL , None BYREMO TE

None

None

BC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

ON

E1/T1 port

None

Read & Write

E1/T1 port

LOOPTY PE_TDM, LOOP_TY PE_LVDS None , LOOPTY PE_MCC

None

None

LAPDLNK None

Read & Write

Not involved

Not involved

0~100

per cent

80

80

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MSC, MS None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NSSAINT F, NSSTCT OABIS, NSSTCT OA, NSSTNU TOABIS, NSSTNU TOA, NSSATE RINTF, BSSATE RINTF, None BSSTCT OABIS, BSSTCT OA, BSSTNU TOABIS, BSSTNU TOA, BSSABISI NTF, BTSTMU, BTSTRU DSP

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO_LOO P, REMOTE _LOOP, LINE_RE MOTE_L OOP, LOCAL_L None OOP, PAYLOA D_LOOP, SIN_CHN _LOC, CIN_CHN _REM

None

None

E1/T1 port

None

Read & Write

E1/T1 port

NO_LOO P, REMOTE None _LOOP, LOCAL_L OOP

None

None

Loopback optical None port

Read & Write

BSC6900

60~600

180

180

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~100

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid when "FLEXABI SMODE" Read & in the Write "MOD BTS" command is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

You are advised to disable this function in the co-BCCH Cell cell with the inter-site distance not more than 1500m.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

For EPS4815 boards, the value of this BTS parameter is set to "NO".

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

E1, TIMESLO None T

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~988

None

None

None

IP path

When the value of "CARRYF LAG" in "ADD IPPATH" Read & is set to Write IP LGCPOR T, this parameter is valid.

IP path

FG2a/GO Ua board:0~1 19;FG2c board:0~4 89, 512~767; None GOUc board:0~4 99, 512~767; POUc(IP) board:0~9 88, 1024~153 FG2a/GO Ua/UOIa(I P) board:0~1 19;FG2c board:0~4 89, 512~767; None GOUc board:0~4 99, 512~767; POUc(IP) board:0~9 88, 1024~153

None

None

IP logical None port

Read & Write

Not involved

Not involved

None

None

IP logical None port

Read & Write

Not involved

Not involved

0~5, 8~27 None

None

None

IP path

When the value of "CARRYF LAG" in "ADD IPPATH" Read & is set to Write IP LGCPOR T, this parameter is valid. None Read & Write

IP path

Hub, Leaf None

None

None

ATM logical port

Not involved

Not involved

IR, LA

None

IR

IR

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

DISABLE

DISABLE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

35.0~55.6 V (step: 0.1)

None

If "Power System Type" is "SC48200", the recommende d value is "475". For BTS other Power System Type of APMU boards, the recommende d value is "440".

The value of this parameter must be smaller Read & than "DC Write Undervolt age Alarm Threshold ".

N (No impact on Not the UE in involved idle mode)

CLOSE, PSDOWN , AMRC, None CSPH, CSFHHO

CSPH

CSPH

BSC

If this parameter is not set to CLOSE, it value must not Read & be the Write same as "LDRSND ", "LDRFST ", or "LDRFOU H".

N (No impact on Not the UE in involved idle mode)

EXCLUD E, None INCLUDE

None

INCLUDE

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

HORIZO NTAL, None VERTICA L

HORIZONTA None L

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HORIZO NTAL, None VERTICA L

HORIZONTA HORIZONTA None L L

None

Read & Write

N (No impact on Not the UE in involved idle mode)

APPLICA TION, SCNDCP U_PROG, None BOOTRO M, DATA, DSP, FAN

APPLICATIO APPLICATIO None N N

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OPTLOG, None SECLOG

OPTLOG

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OPTLOG, None SECLOG

None

OPTLOG

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

-99~70

degree Celsius

BTS

The value of this parameter must be smaller Read & than Write "High Temperat ure Critical Point".

N (No impact on Not the UE in involved idle mode)

-99~99

degree Celsius

-1

-1

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~255

None

Cell

The setting of this parameter must meet the following conditions Read & : Write "LTFERL OWTH" < "LTFERT GT"; "LTFERL OWTH" < "LTFERU PTH".

N (No impact on Not the UE in involved idle mode)

2~255

None

Cell

The setting of this parameter must meet the following conditions Read & : Write "LTFERL OWTH" < "LTFERT GT"; "LTFERT GT" < "LTFERU PTH".

N (No impact on Not the UE in involved idle mode)

2~255

None

60

60

Cell

The setting of this parameter must meet the following conditions Read & : Write "LTFERU PTH" > "LTFERT GT"; "LTFERU PTH" > "LTFERL

N (No impact on Not the UE in involved idle mode)

2~255

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~12

None

Board

None

Read & Write

Cell

14, 15, 16, 18, 20, 22, None 24, 26, 28, 30, 33, 36, 88

20

20

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

18, 20, 22, 24, 26, 28, None 30, 32, 35, 38, 41, 45, 88

30

30

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

ENABLE

For EPS4815, the recommende d value is "DISABLE". For other BTS types of APMU boards, the recommende d value is "ENABLE".

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1024~655 None 35

2905

2905

SCTP link None

Read & Write

SCTP link

0~8191

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

None

10

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

None

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CA_MA, Frequenc y_List, None OPTIMIZ ED_CA_ MA

CA_MA

CA_MA

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~499

None

None

None

Board

None

Read & Write

Not involved

Not involved

NO, YES None

YES

YES

Cell

This parameter is valid when " MAINBC CHPWRD Read & TEN " in Write the " SET GCELLO THEXT " command is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

None

None

Cell

This parameter is valid when " MAINBC CHPWRD Read & TEN " in Write the " SET GCELLO THEXT " command is set to YES.

N (No impact on Not the UE in involved idle mode)

0~3, Step:0.2

dB

Cell

This parameter is valid when " MAINBC CHPWRD Read & TEN " in Write the " SET GCELLO THEXT " command is set to YES. This parameter is valid when " MAINBC CHPWRD Read & TEN " in Write the " SET GCELLO THEXT " command is set to YES.

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

0:00

None

Cell

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~35

None

None

None

BTS

None

Read & Write

Not involved

Not involved

0~1

None

BTS

None

Read & Write

BTS

0~9999

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Cell

This parameter is valid only when "IBCAALL Read & OWED" in Write "SET GCELLC HMGAD" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~20 character None s

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

1~20 character None s

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

PPP link

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

255.255.255. 255.255.255. BTS 255 255

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

PPP link

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

PPP link

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~32

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~254

None

None

4(application type is M3UA), SCTP link None 10(applicatio n type is BBAP)

Read & Write

N (No impact on Not the UE in involved idle mode)

64~10000 kbit/s 0, step:64

None

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

1~20

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~20

dB

10

10

BTS

This parameter is valid only when Read & "BAKPW Write RSAVME THOD" is set to BYPWR.

N (No impact on Not the UE in involved idle mode)

1~2

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~2

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

24~1031

byte

1031

1031

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

50~200

None

100

100

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~1500

byte

256

256

PPP link

None

Read & Write

PPP link

1~1500

None

None

None

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10000~15 None 0000

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

100~1000 00 (step: W 100)

125

125

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

None

2(application type is M3UA), SCTP link None 5(application type is BBAP)

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

None

BSC

This parameter is valid only when "TYPE" in Read & "SET Write BSCPCU TYPE" is set to OUTER.

N (No impact on Not the UE in involved idle mode)

0~8

None

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1C, 2C, 3C, 4C, 5C, 6C, 7C, 8C, 9C, 10C, 11C, 12C, 13C, 14C, 15C, 16C, 17C, 18C, 19C, 20C, 21C, 22C, 23C, 24C, 25C, 26C, 27C, 28C, 29C, 30C, 31C, 32C, 33C, 34C, None 35C, 36C, 37C, 38C, 39C, 40C, 41C, 42C, 43C, 44C, 45C, 46C, 47C, 48C, 49C, 50C, 51C, 52C, 53C, 54C, 55C, 56C, 57C, 58C, 59C, 60C, 61C, 62C, 63C, 64C, 65C, 66C, 67C, 68C,

15C

15C

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5C, 7C, 10C, 12C, 15C, 18C, None 20C, 22C, 25C

15C

15C

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1_Times, 2_Times, None 4_Times, 7_Times

7_Times

7_Times

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1_Times, 2_Times, None 4_Times, 7_Times

7_Times

7_Times

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1_Times, 2_Times, None 4_Times, 7_Times

7_Times

7_Times

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1_Times, 2_Times, None 4_Times, 7_Times

7_Times

7_Times

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~746

byte

64

64

PPP link

None

Read & Write

PPP link

1~746

None

None

None

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~30

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~30

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~30

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~255

None

62

In Normal cell,the recommende d value is 62;in Double Timeslot Cell Extension Cell,the recommende d value is 219.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

255

255

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~24

12

12

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~32

None

32

32

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~255

None

16

16

None

None

Read & Write

Not involved

Not involved

0~32

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

1~999

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~511

None

None

None

None

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

None

None

Read & Write

Not involved

Not involved

0~3

None

If the traffic volume on each frequency band is even and there is no special requirements for the frequency band, the recommende d value is 0; if the traffic volume on each frequency Cell band is significantly uneven and a frequency band is preferred for an MS, the recommende d value is 3; if traffic volume on each frequency band is not extremely uneven, the recommende

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:0~1 4880, step:480; ms SDCCH:0 ~14570, step:470

Cell

This parameter is valid only when "MEASU RETYPE" Read & in "SET Write GCELLC CUTRAN SYS" is set to EnhMeas Report.

N (No impact on Not the UE in involved idle mode)

TCH:0~1 4880, step:480; ms SDCCH:0 ~14570, step:470

Cell

This parameter is valid only when "MEASU RETYPE" Read & in "SET Write GCELLC CUTRAN SYS" is set to EnhMeas Report.

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

3 digit

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~3 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

4, 8

None

None

None

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

4(Use two bytes to present MC priority number, 4 classes), None 8(Use four bytes to present MC priority number, 8

BTS

This parameter is required when "MLPPP Read & type" is Write set to "MCPPP" with the "ADD BTSMPG RP".

PPP link

0~2047

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BTS

"BTSTYP E" identifies the value range of this parameter . The number of cabinets supported by the Read & BTS Write depends on the type of the BTS. For details, see the parameter descriptio n of the command .

N (No impact on Not the UE in involved idle mode)

ON, OFF None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLASS0, CLASS1, None CLASS2

CLASS0

CLASS0

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

Board

None

Read & Write

Not involved

Not involved

0~7

None

Ethernet port

None

Read & Write

Not involved

Not involved

1~20 character None s

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

1~20 character None s

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~5

BSC

Set when Allow Common Read & Measure Write ment at Iur-g is set to Yes

N (No impact on Not the UE in involved idle mode)

EnhMeas Report, None ComMeas Report

ComMeasRe ComMeasRe Cell port port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~1000

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

1~8191

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

LocalMep , None RemoteM ep

None

None

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

LONG, SHORT

None

LONG

LONG

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

LONG, SHORT

None

LONG

LONG

BTS

None

Read & Write

PPP link

0~63

None

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

64~10000 kbit/s 0, step:64

None

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~49

dB

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

This parameter is based on "HOCDC MINDWP WR" and "HOCDC MINUPP WR". Different offset can be set for different neighbori ng cells. Read & The following Write condition must be met for a neighbori ng cell to be added into the candidate cell queue: Neighbori ng cell uplink level >= ("HOCDC MINUPP

N (No impact on Not the UE in involved idle mode)

10~3500

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2000

mA

170

170

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

140

140

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

140

140

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

16

16

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM1.

N (No impact on Not the UE in involved idle mode)

60~3600

60

60

Cell

This parameter is valid only when "SDDYN" Read & in "SET Write GCELLB ASICPAR A" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~63

dB

10

10

Cell

A 3G cell can be added into the candidate cell queue when the following conditions are met: "INTERR ATOUTB SCHOEN " is set to YES; Read & "BET3GH Write OEN" is set to YES; the RSCP of the 3G cell for a period of time is greater than the sum of "HORSC PTH3G" and "RSCPOF

N (No impact on Not the UE in involved idle mode)

10~1000

ms

100

100

Ethernet port

None

Read & Write

Not involved

Not involved

10~1000

ms

100

100

Current BFD session

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~1000

ms

100

100

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~1000

ms

100

100

Current BFD session

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0~11

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

UP, DOWN

None

None

None

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~3 digit

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

50~95

per cent

80

80

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MANUAL, AUTO, None FREE

AUTO

AUTO

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

SERVER, None CLIENT

None

None

SCTP link None

Read & Write

SCTP link

OFF, ON None

None

OFF

BSC6900 None

Read & Write

Not involved

Not involved

GO, UO, GU

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

FIXED, CYCLE

None

None

None

None

None

Read & Write

Not involved

Not involved

MODE1, MODE2, MODE3, MODE4

None

None

None

MSP protect group

None

Read & Write

BSC6900

CHECK_ ON_INDE PENDEN T_PORT, CHECK_ ON_PRIM None ARY_PO RT, CHECK_ ON_STA NDBY_P ORT

None

None

None

None

Read & Write

Not involved

Not involved

MODE1, MODE2, MODE3

None

MODE1

MODE1

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MODE1, MODE2, MODE3

None

MODE1

MODE1

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MODE1, MODE2, MODE3

None

MODE1

MODE1

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MODE1, MODE2, MODE3

None

MODE1

MODE1

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MODE1, MODE2, MODE3

None

MODE1

MODE1

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MODE1, MODE2, MODE3

None

MODE1

MODE1

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30MINS, 60MINS, None 120MINS, 240MINS

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~1440

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~12

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~600

m/s

35

35

Cell

This parameter is valid only when "QUICKH Read & OEN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

10

10

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31(PE Ua), 0~167(P OUc)

None

None

None

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~167

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

None

None

BTS

None

Read & Write

PPP link

MODE1_ 1, MODE2_ 1, MODE3_ 1, MODE4_ None 1, MODE5_ 1, MODE6_ 1, MODE16 K

MODE4_1

MODE4_1

BTS

This parameter can be set to MODE5_ 1 or MODE6_ Read & 1 only Write when "FLEXABI SMODE" is set to FLEX_AB IS.

BTS

0~1

None

None

If "BTS Type" is "BTS3900E_ GSM", the BTS recommende d value is "0".

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

ENABLE

ENABLE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MLPPP, MCPPP

None

MCPPP

MCPPP

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~31

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

NOreport, Twice_ps, Once_ps, None Once_2s, Once_4s

Once_ps

Once_ps

Cell

This parameter must be set when "BTSMES Read & RPTPRE Write PROC" is set to BTS_Pre processin gN.

N (No impact on Not the UE in involved idle mode)

4~30

dB

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

4~30

dB

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON_WIT H_SDCC H, None ON_WIT HOUT_S DCCH

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

128~1500 None

1500

1500

BTS

None

Read & Write

PPP link

1~16

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

1800

1800

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1023

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFFLOA D, None NORMAL, UNAVAIL

NORMAL

NORMAL

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

R98_or_b elow, None R99_or_a bove

R98_or_belo None w

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5000~400 ms 00

15000

15000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when "QUICKH Read & OEN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

1_Times, 2_Times, None 4_Times, 7_Times

4_Times

4_Times

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLEAR, LOP, FS, None MS, EXERS,

None

None

MSP protect group

None

Read & Write

Not involved

Not involved

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, MCS9

None

MCS5

MCS5

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~80

None

40

40

Cell

The value of this parameter must be smaller than or Read & equal to Write "PDCH Downlink Multiplex Threshold ".

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

200

200

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~300 ms 0

1000

1000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~600

45

45

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

None

ON

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

50~95

per cent

85

85

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ALARM_ METHOD , None LOOP_M ETHOD 0~31(EIU a/OIUa), None 0~63(PO Uc)

None

None

E1/T1 port

None

Read & Write

Not involved

Not involved

None

None

MTP3 link None

Read & Write

Not involved

Not involved

MET, IMP None

MET

MET

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

500~1500 None

800

800

SCTP link None

Read & Write

N (No impact on Not the UE in involved idle mode)

256~1650 byte

None

1500

Ethernet port

None

Read & Write

BSC6900

0~1500

None

1500

If "MTU" is set to a value smaller than 576, the DHCP procedure may fail when the BTS tries to retrieve the IP address, and thus the BTS cannot work. The BTS recommende d value of this parameter is 1500. Do not modify it unless in special scenarios, for example, at the bottom layer where the number of MTU is

None

Read & Write

N (No impact on Not the UE in involved idle mode)

19.0~24.0 V , step:0.1

225

225

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

REPORT 6, REPORT 1, None REPORT 2, REPORT 3

REPORT6

REPORT6

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

Cell

This parameter is valid when Read & "TCMUTE Write DETECT FLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

None

DISABLE

Cell

This parameter is valid when Read & "TCMUTE Write DETECT FLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~10

None

Cell

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

min

Cell

None

Read & Write

Not involved

Not involved

NO, YES None

NO

NO

Cell

None

Read & Write

Not involved

Not involved

1~1500

ls

1000

1000

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~1500

ls

None

None

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

UDPMUX , ABISMUX None , ATERMU X

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~12

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~16(FG2 a/GOUa), None 1~512(FG 2c/GOUc)

None

None

None

None

Read & Write

Not involved

Not involved

1~3

None

When the transmission quality is good, the recommende d settings are as follows: "Ring II Wait Time Before Switch" = 0; "Ring II Try Rotating Duration Time" = 60; "Ring II Rotating Penalty BTS Time" = 0; "T200" = 12; "T203" = 1; and "N200" = 3. When the transmission quality is bad, the recommende d settings are as follows: "Ring II Wait Time Before Switch" = 30; "Ring II Try Rotating

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~254

None

Cell

N200EST AB must be set when Read & "N200PA Write RASWIT CH" is set to YES.

N (No impact on Not the UE in involved idle mode)

34~254

None

34

34

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

29~254

None

29

29

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~254

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~254

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

23~254

None

23

23

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

8~30

None

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~5

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

3~10

None

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

BC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

BC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

BC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

None

Cell

This parameter is valid only when "GPRS" is Read & set to Write SupportA sInnPcu or SupportA sExtPcu.

N (No impact on Not the UE in involved idle mode)

1~49 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~49 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~49 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~49 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~49 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~50 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

DISABLE

DISABLE

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5048~804 None 7

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65533, None 65535

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~3 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~3 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

None

Cell

This parameter is valid only when "GPRS" is Read & set to Write SupportA sInnPcu or SupportA sExtPcu.

N (No impact on Not the UE in involved idle mode)

NOTSUP PORT, None SUPPOR T

NOTSUPPO NOTSUPPO BSC RT RT

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

None

Cell

This parameter is valid only when "GPRS" is Read & set to Write SupportA sInnPcu or SupportA sExtPcu.

Cell

0~7

None

None

None

Cell

None

Read & Write

Cell

0~7

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SELECTI ON0_PE RM, SELECTI ON1_PE RM, SELECTI ON2_PE RM, SELECTI ON3_PE RM, None SELECTI ON4_PE RM, SELECTI ON5_PE RM, SELECTI ON6_PE RM, SELECTI ON7_PE RM

SELECTION 0_PERM1&SELECTI ON1_PERM1&SELECTI ON2_PERM1&SELECTI ON3_PERM1&SELECTI ON4_PERM1&SELECTI ON5_PERM1&SELECTI ON6_PERM1&SELECTI ON7_PERM1

SELECTION 0_PERM1&SELECTI ON1_PERM1&SELECTI ON2_PERM1&SELECTI ON3_PERM1&SELECTI Cell ON4_PERM1&SELECTI ON5_PERM1&SELECTI ON6_PERM1&SELECTI ON7_PERM1

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid only when "QUICKH Read & OEN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

TCH:480 ~14880, step:480; ms SDCCH:4 70~14570 , step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~127

dB

BSC

The following condition must be met: Read & "NcellInter Write FLevelThr es1" > "NcellInter FLevelThr es0". The following condition must be met: "NcellInter FLevelThr Read & es2" > Write "NcellInter FLevelThr es1" > "NcellInter FLevelThr es0".

N (No impact on Not the UE in involved idle mode)

0~127

dB

60

60

BSC

N (No impact on Not the UE in involved idle mode)

0~127

dB

64

64

BSC

The following condition must be met: "NcellInter FLevelThr Read & es3" > Write "NcellInter FLevelThr es2" > "NcellInter FLevelThr es1". The following condition must be met: "NcellInter FLevelThr Read & es4" > Write "NcellInter FLevelThr es3" > "NcellInter FLevelThr es2". The following condition must be met: "NcellInter FLevelThr Read & es5" > Write "NcellInter FLevelThr es4" > "NcellInter FLevelThr es3". The following condition must be met: "NcellInter FLevelThr Read & es6" > Write "NcellInter FLevelThr es5" > "NcellInter FLevelThr es4".

N (No impact on Not the UE in involved idle mode)

0~127

dB

68

68

BSC

N (No impact on Not the UE in involved idle mode)

0~127

dB

72

72

BSC

N (No impact on Not the UE in involved idle mode)

0~127

dB

74

74

BSC

N (No impact on Not the UE in involved idle mode)

0~127

dB

76

76

BSC

The following condition must be met: "NcellInter FLevelThr Read & es7" > Write "NcellInter FLevelThr es6" > "NcellInter FLevelThr es5". The following condition must be met: "NcellInter FLevelThr es7" > "NcellInter FLevelThr es6". The setting of this parameter must meet the following condition: "NCHSTA RTBLOC K"" <= "NCHOC BLOCKN UM". The setting of this parameter must meet the following condition: "NCHSTA RTBLOC K"" <= "NCHOC BLOCKN UM".

N (No impact on Not the UE in involved idle mode)

0~127

dB

80

80

BSC

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

Read & Write

N (No impact on Not the UE in involved idle mode)

NC0, None NC1, NC2

NC0

NC0

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

SCCP

None

Read & Write

BSC6900

0.0.0.0~2 55.255.25 None 5.255

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255 0.0.0.0~2 55.255.25 None 5.255

None

None

IP route

None

Read & Write

Not involved

Not involved

None

None

None

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INT, INTB, NAT, NATB

None

None

None

SCCP

This parameter depends Read & on Write network planning.

Not involved

Not involved

1~62 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NMOI, NMOII, NMOIII

None

NMOII

NMOII

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

The value range of this parameter varies with BTS type. Read & Different Write types of BTSs support a different number of cabinets.

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

The value range of this Read & parameter Write varies with BTS type.

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

40~45

43

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

55~59

57

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

40~45

43

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

55~59

57

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

40~45

43

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

55~59

57

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

40~45

43

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

55~59

57

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

40~45

43

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

55~59

57

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

40~45

43

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

55~59

57

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0~255

dB

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO Read & RITHM2 Write and "NOAMR FULLTOH ALFHOAL LOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

dB

30

30

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO Read & RITHM2 Write and "NOAMR FULLTOH ALFHOAL LOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

dB

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO Read & RITHM2 Write and "NOAMR FULLTOH ALFHOAL LOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

dB

95

95

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO Read & RITHM2 Write and "NOAMR FULLTOH ALFHOAL LOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO Read & RITHM2 Write and "NOAMR FULLTOH ALFHOAL LOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

85

85

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO Read & RITHM2 Write and "NOAMR FULLTOH ALFHOAL LOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

dB

14

14

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO Read & RITHM2 Write and "NOAMR FULLTOH ALFHOAL LOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

dB

103

103

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO Read & RITHM2 Write and "NOAMR FULLTOH ALFHOAL LOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2 and "NOAMR FULLTOH ALFHOAL LOW" is set to

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO Read & RITHM2 Write and "NOAMR FULLTOH ALFHOAL LOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

25

25

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO Read & RITHM2 Write and "NOAMR FULLTOH ALFHOAL LOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

ABIS, A, BSC, TC, None IUR_G

None

None

Adjacent node

None

Read & Write

Not involved

Not involved

0~64

None

Cell

This parameter is valid only when "NODLM Read & RHOEN" Write in "SET GCELLH OEMG" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

50

50

Cell

This parameter is valid only when "NODLM Read & RHOEN" Write in "SET GCELLH OEMG" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~1000

Ah

100

100

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

NODRX, 0.24sec, 0.48sec, 0.72sec, 0.96sec, 1.20sec, 1.44sec, 1.92sec

0.24sec

0.24sec

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

100~1000 ms 0

2500

2500

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

100~1000 ms 0

2500

2500

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FORBID, None PERMIT

PERMIT

PERMIT

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

40.0~70.0 degree (step: 0.1) Celsius

500

500

BTS

The value of this parameter must be Read & 8C Write smaller than "Derating TEMP Threshold

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~1275, step:5

min

48

48

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

10~255

30

30

BTS

This parameter is valid Read & only when Write "ENABLE " is set to YES.

N (No impact on Not the UE in involved idle mode)

1~10

None

None

None

Read & Write

Not involved

Not involved

TCH:0~1 4880, step:480; ms SDCCH:0 ~14570, step:470

Cell

This parameter is valid only when "MEASU RETYPE" Read & in "SET Write GCELLC CUTRAN SYS" is set to EnhMeas Report.

N (No impact on Not the UE in involved idle mode)

TCH:0~1 4880, step:480; ms SDCCH:0 ~14570, step:470

Cell

This parameter is valid only when "MEASU RETYPE" Read & in "SET Write GCELLC CUTRAN SYS" is set to EnhMeas Report.

N (No impact on Not the UE in involved idle mode)

0~1023

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1023

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65534

None

None

None

NSE

None

Read & Write

Not involved

Not involved

0~65534

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~14880, step:480; ms SDCCH:4 70~14570 , step:470

Cell

This parameter is valid only when "HOCTRL SWITCH" Read & in "SET Write GCELLH OBASIC" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

North_latit ude, None South_lati tude

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65534

None

None

None

NSVC

None

Read & Write

Not involved

Not involved

0~1023

None

None

None

NSVC

None

Read & Write

Not involved

Not involved

0~30

degree Celsius

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~30

degree Celsius

16

16

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

None

None

Ethernet port

None

Read & Write

Ethernet port

0~100

per cent

PPP link

None

Read & Write

BSC6900

0~100

per cent

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

Ethernet port

None

Read & Write

Not involved

Not involved

0~63

None

None

None

Port queue

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

Port queue

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SITE, CELL, BOARD

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYCELL, None BYTRX

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~499

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~499

None

None

None

BSC

None

Read & Write

Not involved

Not involved

ALL, BOARD, PORT, DSP

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

BTS, CELL, LOC, BOARD, PORT

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CELL, TRX, CHN

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

OFF

BSC6900 None

Read & Write

Not involved

Not involved

4~255

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~256

kbit/s

64

64

Transport None channel

Read & Write

N (No impact on Not the UE in involved idle mode)

0~256

kbit/s

64

64

Transport None channel

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~7

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~4094

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~96

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~167772 None 15

None

None

BSC

None

Read & Write

Cell

1~167772 None 15

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~4

None

None

None

E1/T1 link None

Read & Write

Not involved

Not involved

PRIM, SEC

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OPINDEX 0, OPINDEX 1, None OPINDEX 2, OPINDEX 3

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NORMAL, None FORCE

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYCICRA NGE, None BYCICVA LUE

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYTSRA NGE, None BYTSVAL UE

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYTSRA NGE, None BYTSVAL UE

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYCICRA NGE, None BYCICVA LUE

None

None

PBCIC

None

Read & Write

Not involved

Not involved

0~255 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SysOpt, OSubcell, None USubcell, NoPrefer

SysOpt

SysOpt

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

0~63

dB

35

35

Cell

This parameter is valid only when "IUOTP" in "ADD GCELL" Read & is set to Write Concentri c_cell and "OPTILAY ER" is set to SysOpt.

N (No impact on Not the UE in involved idle mode)

0~255

bit

63

63

Cell

This parameter is valid only when "IUOTP" in "ADD GCELL" Read & is set to Write Concentri c_cell and "OPTILAY ER" is set to SysOpt.

N (No impact on Not the UE in involved idle mode)

L0, L1, L2, L3, L4, L5, L6, L7

None

L0

L0

TRX

This parameter is valid only when Read & "TRXPRI Write ALLOW" is set to YES.

N (No impact on Not the UE in involved idle mode)

SDH, SONET

None

None

None

Board

None

Read & Write

BSC6900

MANUAL, FORCED, None CLEARAL ARMA

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FORBID, RESTOR None E

None

None

BTS

None

Read & Write

BTS

0~4

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

One_touc h, None Step_by_ Step

Step_by_Ste Step_by_Ste None p p

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~200 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~36

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

20

20

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

500~6000 ms 0

10000

10000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

500~6000 ms 0

10000

10000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when "LOADHO Read & EN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

80

80

Cell

This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. The following condition Read & must be Write met: "OUTSER IOVERLD THRED" > "OUTGE NOVERL DTHRED" > "OUTLO WLOADT HRED".

N (No impact on Not the UE in involved idle mode)

0~50

15

15

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

25

25

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

1~255

Cell

This parameter is valid only when Read & "OUTLOA Write DHOENA BLE" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~255

Cell

This parameter is valid only when Read & "OUTLOA Write DHOENA BLE" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

This parameter is valid only when "OUTLOA DHOENA BLE" is Read & set to Write YES and "IUOTP" in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

50

50

Cell

This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. The Read & following Write condition must be met: "OUTGE NOVERL DTHRED" > "OUTLO WLOADT HRED".

N (No impact on Not the UE in involved idle mode)

TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, None TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

BSC

None

Read & Write

Not involved

Not involved

0~335

None

None

None

BSC

None

Read & Write

Not involved

Not involved

0~15

None

None

None

BTS

None

Read & Write

BTS

0~31

None

None

None

BTS

None

Read & Write

BTS

HIGH, LOW

None

HIGH

HIGH

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HIGH, LOW

None

HIGH

HIGH

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HIGH, LOW

None

HIGH

HIGH

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HIGH, LOW

None

HIGH

HIGH

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1.0~200.0 W (step: 0.1)

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30.0~53.0 dB (step: 0.1)

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.1dB, 0.1W

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

90

90

Cell

This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. The following condition Read & must be Write met: "OUTSER IOVERLD THRED" > "OUTGE NOVERL DTHRED" > "OUTLO WLOADT HRED".

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

BSC

None

Read & Write

Not involved

Not involved

0~27

None

None

None

BSC

None

Read & Write

Not involved

Not involved

0~11

None

None

None

BSC

None

Read & Write

Not involved

Not involved

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

This parameter is valid only when Read & "OUTSYS Write SERVICE HOEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

CLOSE

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

15

15

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BSC

None

Read & Write

Not involved

Not involved

10~3500

mA

320

320

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

320

320

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

185

185

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

280

280

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

280

280

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

155

155

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

100~1000 ms 0

1500

1500

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

100~1000 ms 0

1500

1500

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

40.0~70.0 degree (step: 0.1) Celsius

580

580

BTS

The value of this parameter must be 8C Read & greater Write than "Normal Work TEMP Threshold

N (No impact on Not the UE in involved idle mode)

50~95

per cent

90

90

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

50~95

per cent

85

85

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

50~95

per cent

80

80

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

50~95

per cent

75

75

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

Not involved

10~65535 None

180

180

Cell

This parameter is valid when "ALLOW G2FLOW CTRALG Read & L" in the Write "SET BSCFCP ARA" command is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

ms

255

255

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~65535 None

220

220

Cell

This parameter is valid when "ALLOW G2FLOW CTRALG Read & L" in the Write "SET BSCFCP ARA" command is set to YES.

N (No impact on Not the UE in involved idle mode)

1~8

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Pan_0, Pan_1, Pan_2, Pan_3, Pan_4, Pan_5, Pan_6, Pan_7, 255

None

Pan_1

Pan_1

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Pan_0, Pan_1, Pan_2, Pan_3, Pan_4, Pan_5, Pan_6, Pan_7, 255

None

Pan_2

Pan_2

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Pan_4, Pan_8, Pan_12, Pan_16, Pan_20, Pan_24, Pan_28, Pan_32, 255

None

Pan_20

Pan_20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

L0, L1, L2, L3, L4, L5, L6, L7

None

L0

L0

TRX

This parameter is valid only when "BSCDyn SwitchTrx PAAllow" in "SET BSCDST Read & PA","DYN Write OpenTrxP ower" in "SET GCELLB ASICPAR A" and "CPS" are set to YES.

N (No impact on Not the UE in involved idle mode)

0~9999

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~99

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ENABLE D, None DISABLE D

DISABLED

DISABLED

IP path

None

Read & Write

Not involved

Not involved

0~65535

None

None

None

IP path

None

Read & Write

Not involved

Not involved

0~65535

None

None

None

IP path

None

Read & Write

Not involved

Not involved

0~25.5, step:0.1

dB

79

79

Cell

This parameter is valid only when Read & "PWRBC Write DALLOW D" is set to YES. This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

N (No impact on Not the UE in involved idle mode)

QoS, BE, AF11, AF12, AF13, AF21, AF22, AF23, None AF31, AF32, AF33, AF41, AF42, AF43, EF

None

QoS

IP path

None

Read & Write

Not involved

Not involved

MAINCP U_PATC H, DSP_PAT None CH, UCODE_ PATCH

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DB0, DB2, DB4, DB6, DB8, DB10, DB12, DB14, DB16, DB18, DB20, DB22, DB24, DB26, DB28, DB30

dB

DB2

DB2

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM1.

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM1 and "PBGTHO Read & EN" is set Write to YES. The following condition must be met: "PBGTST AT" >= "PBGTLA ST".

N (No impact on Not the UE in involved idle mode)

0~127

dB

68

In densely populated urban areas, the recommende Cell d value is 68; in the suburbs, the recommende d value is 72.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM1 and "PBGTHO Read & EN" is set Write to YES. The following condition must be met: "PBGTST AT" >= "PBGTLA ST".

N (No impact on Not the UE in involved idle mode)

0~65535

None

BSC

This parameter is valid only when "TYPE" in Read & "SET Write BSCPCU TYPE" is set to OUTER.

N (No impact on Not the UE in involved idle mode)

TCH:480 ~7200, step:480; ms SDCCH:4 70~7050, step:470

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

BCCH, PDCH

None

PDCH

PDCH

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

PBCIC

None

Read & Write

Not involved

Not involved

0~31

None

None

None

BSC

None

Read & Write

Not involved

Not involved

0~31

None

None

None

PBE1T1

None

Read & Write

Not involved

Not involved

0~31

None

None

None

Cell

This parameter is valid only when Read & "GPRS" is Write set to SupportA sExtPcu.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~160

None

80

80

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~70

None

70

70

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

SCCP

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65534

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65534

None

None

None

BTS

None

Read & Write

BTS

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

BTS

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

BTS

0~2047

None

None

None

BTS

None

Read & Write

BTS

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

None

None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

The peer IP address and the local IP address specified by "Local IP address" must be on the same network The peer IP address and the local IP address specified by "Local IP address" must be on the same network

Read & Write

PPP link

Read & Write

PPP link

0.0.0.0~2 55.255.25 None 5.255

None

None

SCTP link None

Read & Write

SCTP link

0.0.0.0~2 55.255.25 None 5.255

None

None

SCTP link None

Read & Write

SCTP link

0.0.0.0~2 55.255.25 None 5.255

None

None

IP path

0.0.0.0~2 55.255.25 None 5.255

255.255.255. 255.255.255. IP path 255 255

"IPADDR" and "PEERIP ADDR" in "ADD IPPATH" must be at one network segment;( "IPADDR" ,"PEERIP ADDR","P EERMAS K" in "ADD IPPATH") conflicts with other IPPATH whose type is IUPS. ("IPADDR ","PEERI PADDR"," PEERMA SK" in "ADD IPPATH") conflicts with other IPPATH whose type is IUPS.

Read & Write

Not involved

Not involved

Read & Write

Not involved

Not involved

1024~655 None 35

None

None

SCTP link None

Read & Write

SCTP link

1~63 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

255

255

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

IP path

When the value of "PATHCH K" in "ADD Read & IPPATH" Write is set to ENABLE D, this parameter is valid.

N (No impact on Not the UE in involved idle mode)

15~720, step:15

min

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Disable, Enable

None

Enable

Enable

PPP link

None

Read & Write

PPP link

Disable, Enable

None

Enable

Enable

MP link

None

Read & Write

BSC6900

NO, YES None

YES

YES

BTS

None

Read & Write

PPP link

NO, YES None

NO

NO

NSE

None

Read & Write

NSE

0~2

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~1000

None

660

660

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~2000

None

660

660

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

100~6000 ms 00

1000

1000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BE, AF11, AF12, AF13, AF21, AF22, AF23, None AF31, AF32, AF33, AF41, AF42, AF43, EF

None

None

Board

The phb of the traffic's transmissi on path is determine d like this: if the phb of this transmissi on path is QOS, use the traffic's phb from Read & TRMMAP; Write if the phb of this transmissi on path is BE,AF11, AF12,AF1 3,AF21,A F22,AF23 ,AF31,AF 32,AF33, AF41,AF4 2,AF43,E F, use the phb of

Not involved

Not involved

BE, AF11, AF12, AF13, AF21, AF22, AF23, None AF31, AF32, AF33, AF41, AF42, , AF43, EF

None

None

IP Path

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (Impact on the UE Not in idle involved mode)

DISABLE, None ENABLE

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~64

None

10

10

BSC6900 None

Read & Write

Ethernet port

64~1024

byte

128

128

BSC6900 None

Read & Write

Ethernet port

2~1500

byte

None

None

BC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

24~1031

byte

1031

1031

BTS

This parameter must meet the following requireme nts: The sum of the value of "Max Read & subframe Write length" and 8 must be smaller than the value of this parameter .

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

None

Cell

This parameter is valid only when "GPRS" is Read & set to Write SupportA sInnPcu or SupportA sExtPcu.

Cell

20~1500

byte

56

56

Ethernet port

None

Read & Write

Not involved

Not involved

95~512

byte

128

128

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0_level, 1_level, 2_level, 3_level, 4_level, 5_level, 6_level, 7_level, 8_level, None 9_level, 10_level, 11_level, 12_level, 13_level, 14_level, 16_level, no use

12_level

12_level

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, step:0.2

dB

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0_level, 1_level, 2_level, 3_level, 4_level, 5_level, 6_level, 7_level, 8_level, None 9_level, 10_level, 11_level, 12_level, 13_level, 14_level, 16_level, no use

13_level

13_level

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0_level, 1_level, 2_level, 3_level, 4_level, 5_level, 6_level, 7_level, 8_level, None 9_level, 10_level, 11_level, 12_level, 13_level, 14_level, 16_level, no use

14_level

14_level

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, step:0.2

dB

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0_level, 1_level, 2_level, 3_level, 4_level, 5_level, 6_level, 7_level, 8_level, None 9_level, 10_level, 11_level, 12_level, 13_level, 14_level, 16_level, no use

16_level

16_level

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, step:0.2

dB

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

100~1000 0, ms step:100

10

10

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1, step:0.00 None 1

30

30

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

A, ABIS

None

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~600

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

60

60

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

60

67

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

50~400, step: 50

ms

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~15

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN, AUTO

None

OPEN

OPEN

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

50

50

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

50

62

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

ON

ON

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

E1/T1 link None

Read & Write

Not involved

Not involved

0~335

None

None

None

E1/T1 link None

Read & Write

Not involved

Not involved

0~335

None

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

PBE1T1

None

Read & Write

Not involved

Not involved

0~335

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

Board

None

Read & Write

Not involved

Not involved

0~31(PE Ua/EIUa), 0~62(E1 of OIUa), 0~83(T1 None of OIUa), 0~251(E1 of POUc), 0~335(T1 of POUc) 0~31(PE Ua/EIUa), 0~62(E1 of OIUa), 0~83(T1 None of OIUa), 0~251(E1 of POUc), 0~335(T1 of POUc)

None

None

E1/T1 port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31(PE Ua/EIUa), 0~62(E1 of OIUa), 0~83(T1 None of OIUa), 0~251(E1 of POUc), 0~335(T1 of POUc)

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

Loopback optical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

BSC6900 None

Read & Write

BSC6900

0(OIUa), 0~3(POU None c)

None

None

Board

None

Read & Write

Not involved

Not involved

0~7

None

None

None

Channeliz ed optical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7(FG2a ), 0~1(GOU a), None 0~11(FG2 c), 0~3(GOU c)

None

None

Ethernet port

If port 0 or port 4 of the FG2a board is set to the GE port, the port number can only be 0 or 4. Otherwise , the port number ranges Read & from 0 to Write 7. If only port 0 is set to the GE port, ports 1-3 are unavailabl e. If port 4 is set to the GE port, ports 5-7 are unavailabl e. Read & Write

Not involved

Not involved

0~11

None

None

None

IP logical None port

Not involved

Not involved

0~7(FG2a ), 0~1(GOU a), None 0~11(FG2 c), 0~3(GOU c)

None

None

None

None

Read & Write

Not involved

Not involved

0~335

None

None

None

E1/T1 port

None

Read & Write

Not involved

Not involved

0~31

None

None

None

E1/T1 port

None

Read & Write

Not involved

Not involved

0~335

None

None

None

E1/T1 port

None

Read & Write

Not involved

Not involved

0~335

None

None

None

PBSL

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~355

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

PPP link

None

Read & Write

BTS

0~23

None

None

None

BTS

None

Read & Write

BTS

0~335

None

None

None

BTS

None

Read & Write

BTS

0~1

None

None

None

BTS

None

Read & Write

BTS

0~1

None

None

None

BTS

None

Read & Write

BTS

0~255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

250~650

None

650

650

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

6~120

None

16

16

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

6~120

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NotSuppo rt, None Support

Support

Support

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~9

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~9

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~250 character None s

None

None

BSC6900 None

Read & Write

Not involved

Not involved

1~250 character None s

None

None

BSC6900 None

Read & Write

Not involved

Not involved

21~65535 None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

None

None

BTS

None

Read & Write

Not involved

Not involved

0~1

None

None

None

BTS

None

Read & Write

Not involved

Not involved

0~15

None

None

None

BTS

None

Read & Write

BTS

1~16

None

16

16

BTS

None

Read & Write

BTS

IP, HDLC None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ETHER, TRUNK

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

TOPEXT OUTPOR T, None TOPEXTI NPORT

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BCCHNor m, None BCCHExt

BCCHNorm

BCCHNorm

Cell

If this parameter is BCCHExt, "CCCH Blocks Read & Reserved Write for AGCH" must be more than 0.

N (No impact on Not the UE in involved idle mode)

BYBTSTY PE, None BYBTS

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.1~100.0 kVA (step: 0.1)

125

125

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

None

100

100

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, step: 0.2

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, step: 0.2

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

POWER_ 48_24, None POWER_ 240_24

POWER_48 POWER_48 BTS _24 _24

None

Read & Write

N (No impact on Not the UE in involved idle mode)

220VAC, N48VDC, None P24VDC

220VAC

220VAC

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~13

None

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

80W, 63W, 60W, 55W, 50W, 45W, 40W, 31W, 30W, 27W, 26W, 25W, 24W, 21W, 20W, 19W, 18W, 17W, 16W, 15W, 14W, 13_3W, 13W, 12_5W, 12W, 11_5W, 11W, 10W, 9_5W, 9W, 8_5W, 8W, 7_5W, 7W,

None

DEFAULT

None

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

10

10

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~499

None

None

None

PPP link

None

Read & Write

Not involved

Not involved

0~499

None

None

None

MP link

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~499

None

None

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

None

None

PPP link

None

Read & Write

Not involved

Not involved

Disable, Enable

None

Disable

Disable

MP group None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5

None

When the value of "PORTPR OTYPE" in "ADD PORTFL Read & BSC6900 OWCTRL Write PARA" is set to IP, this parameter should be set.

N (No impact on Not the UE in involved idle mode)

YES, NO None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ALLOWE D, None NOT_ALL OWED

NOT_ALLO WED

NOT_ALLO WED

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

60

60

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 3, 4, 5, None 6

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter must be set when "BTSMES RPTPRE PROC" is set to BTS_Pre processin g. This parameter must be Read & set to NO Write when "MPMOD E" of the BTS that serving this cell is set to MODE4_ 1 and there are more than two SDCCHs.

N (No impact on Not the UE in involved idle mode)

30~100

per cent

60

60

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

60

72

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

50

50

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

50

65

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

ON

ON

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PRIOR-1, PRIOR-2, PRIOR-3, PRIOR-4, PRIOR-5, PRIOR-6, PRIOR-7, PRIOR-8, PRIOR-9, PRIOR10, PRIOR- None 11, PRIOR12, PRIOR13, PRIOR14, PRIOR15, PRIOR16

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Prior-1, Prior-2, Prior-3, Prior-4, Prior-5, Prior-6, Prior-7, Prior-8, Prior-9, Prior-10, Prior-11, Prior-12, Prior-13, Prior-14, Prior-15, Prior-16

None

Prior-1

Prior-1

Cell

This parameter , together with Read & "LAYER", Write determine s the priority of the cell.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

80

80

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 1, 2, 3, 4, 5, 6, 7, None no use

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~99

None

SCCP

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~99

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HIGH, LOW

None

None

None

IP route

None

Read & Write

Not involved

Not involved

TDME1_ O, TDME1_1 None , FE_E, FE_O, IPOE

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1, 2

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TDME1_ O, TDME1_1 None , FE_E, FE_O, IPOE

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~200 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

DEFAULT , CUSTOM None IZDE, DISABLE

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ITUT, ANSI, TTC

None

ITUT

ITUT

SCCP

None

Read & Write

Not involved

Not involved

Q933, ANSI

None

Q933

Q933

BC

None

Read & Write

BC

5~300

15

15

BTS

None

Read & Write

Not involved

Not involved

0~255

min

Cell

This parameter is valid only when Read & "TURNOF Write FENABLE " is set to YES.

N (No impact on Not the UE in involved idle mode)

60~3600

300

300

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ALL, SINGLE

None

None

ALL

E1/T1 port

None

Read & Write

Not involved

Not involved

ALL, SINGLE

None

None

None

Board

None

Read & Write

Not involved

Not involved

ALL, PORT, SINGLE

None

None

ALL

Channeliz ed optical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC

This parameter is valid only when Read & "PS CHR Write Record Switch" is set to on.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

When "Mode Control" is set to "Common User Mode", the recommende BSC d value is OFF; when "Mode Control" is set to "Specified User Mode", the

This parameter is valid only when Read & "PS CHR Write Record Switch" is set to on.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

BSC

This parameter is valid only when Read & "PS CHR Write Record Switch" is set to on.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

When "Mode Control" is set to "Common User Mode", the recommende d value is OFF; when BSC "Mode Control" is set to "Specified User Mode", the recommende d value is ON.

This parameter is valid only when Read & "PS CHR Write Record Switch" is set to on.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

BSC

This parameter is valid only when Read & "PS CHR Write Record Switch" is set to on.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

100

100

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

100

100

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

NSE

None

Read & Write

NSE

BE, AF11, AF12, AF13, AF21, AF22, AF23, None AF31, AF32, AF33, AF41, AF42, AF43, EF

None

When the value of When the "ITFT" in interface type "ADD Read & is Abis, the BSC6900 TRMMAP Write parameter is " is set to AF43. ABIS, this parameter is valid.

N (No impact on Not the UE in involved idle mode)

0~7

None

None

When the When the value of interface type "ITFT" in is Abis and "ADD transmission Read & BSC6900 TRMMAP type is Write " is set to HDLC, the ABIS, this parameter is parameter 1. is valid.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~16

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BE, AF11, AF12, AF13, AF21, AF22, AF23, None AF31, AF32, AF33, AF41, AF42, AF43, EF

None

When the When the value of interface type "ITFT" in is Abis, "ADD Read & transmission BSC6900 TRMMAP Write type is IP, the " is set to parameter is ABIS, this AF33. parameter is valid.

N (No impact on Not the UE in involved idle mode)

0~7

None

None

When the When the value of interface type "ITFT" in is Abis and "ADD transmission Read & BSC6900 TRMMAP type is Write " is set to HDLC, the ABIS, this parameter is parameter 2. is valid.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

25

25

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

COMMO NUSRM, None SPECUS RM

None

None

BSC

This parameter is valid Read & only when Write "PSRCDS W" is set to on.

N (No impact on Not the UE in involved idle mode)

-121~104

dBm

-109

-109

Cell

The value of this parameter must be smaller than "RACH Read & Busy Write Threshold " in the "SET GCELLC CBASIC" command .

N (No impact on Not the UE in involved idle mode)

-121~104

dBm

-109

-109

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~10000 None

500

500

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

100~6000 ms 00

1000

1000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

For "Power System Type" is "APM30" or "EPS4815", the recommende d value is BTS "NO". For other types of Power System, the recommende d value is "YES".

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

35

35

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

BOOL, VALUE

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

123~6553 None 4

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

GB_OVE R_FR, None GB_OVE R_IP

None

None

NSE

None

Read & Write

Not involved

Not involved

BOOL, VALUE

None

BOOL

BOOL

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

B8ZS, HDB3, None AMI, AMI_ZCS

None

None

E1/T1 port

None

Read & Write

BSC6900

E1_DOU BLE_FRA ME, E1_CRC4 _MULTI_ FRAME, T1_SUPE None R_FRAM E, T1_EXTE NDED_S UPER_F RAME

None

None

E1/T1 port

None

Read & Write

BSC6900

E1_DOU BLE_FRA ME, E1_CRC4 _MULTI_ FRAME, T1_SUPE None R_FRAM E, T1_EXTE NDED_S UPER_F RAME

None

None

E1/T1 port

None

Read & Write

BSC6900

E1_DOU BLE_FRA ME, E1_CRC4 _MULTI_ FRAME, T1_SUPE None R_FRAM E, T1_EXTE NDED_S UPER_F RAME

None

E1_CRC4_M E1/T1 ULTI_FRAM port E

None

Read & Write

BSC6900

0~15

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FE, GE

None

None

None

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

APM100, APM200, APM30, EPS4890, None EPS4815, SC48200, CUSTOM

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~200 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~50 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~50 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

ms

500

500

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

6~32 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BIT0, BIT1, BIT6, BIT7, BIT8, BIT9, BIT14, BIT15, BIT16, BIT17, BIT22, BIT23, BIT24, BIT25, BIT29, BIT0, BIT1, BIT2, BIT3, BIT4, BIT5, BI16, BIT7, BIT8,

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

PWR2, PWR3

None

PWR3

PWR3

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OnlyCurP wrLoc, None ALLPwrL oc

ALLPwrLoc

ALLPwrLoc

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLASS0, CLASS1, None CLASS2

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~720

min

BTS

This parameter is valid only when Read & "BAKPW Write RSAVME THOD" is set to BYPWR.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DB0, DB2, DB4, DB6, DB8, DB10, DB12, DB14, DB16, DB18, Default

None

Default

Default

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

Port queue

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

Port queue

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

Port queue

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

Port queue

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

Port queue

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Use_Qse arch_I, None Always

Use_Qsearc Use_Qsearc Cell h_I h_I

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

Set this parameter to YES only in special Cell scenarios such as highways.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

This parameter is valid only when "QCKMV HOEN" in "SET GCELLH OBASIC" Read & is set to Write YES. The following condition must be met: "QCKSTA TCNT" >= "QCKTRU ECNT".

N (No impact on Not the UE in involved idle mode)

0~255

15

15

Cell

This parameter is valid only when "QCKMV Read & HOEN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

This parameter is valid only when "QCKMV HOEN" in "SET GCELLH OBASIC" Read & is set to Write YES. The following condition must be met: "QCKSTA TCNT" >= "QCKTRU ECNT".

N (No impact on Not the UE in involved idle mode)

-98, -94, 90, -86, 82, -78, 74, (always), 78, -74, None 70, -66, 62, -58, 54, Positive infinity(ne ver)

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~15360, step:480; ms SDCCH:4 70~15040 , step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~15360, step:480; ms SDCCH:4 70~15040 , step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-98, -94, 90, -86, 82, -78, 74, (always), 78, -74, None 70, -66, 62, -58, 54, Positive infinity(ne ver)

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-98, -94, 90, -86, 82, -78, 74, (always), 78, -74, None 70, -66, 62, -58, 54, Positive infinity(ne ver)

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~16

Cell

This parameter is valid only when "QTRUP WRSHAR E" is not set to NONE. The Read & following Write condition must be met: "QTRUD NPWRST ATTIME" >= "QTRUD NPWRLA STTIME".

N (No impact on Not the UE in involved idle mode)

1~16

Cell

This parameter is valid only when "QTRUP WRSHAR E" is not set to NONE. The Read & following Write condition must be met: "QTRUD NPWRST ATTIME" >= "QTRUD NPWRLA STTIME".

N (No impact on Not the UE in involved idle mode)

NONE, None DYNAMIC

NONE

NONE

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

3~20

None

BTS

This parameter must be equal to or greater than 0.6x"CHK Read & OFFTIME Write S" and equal to or less than "CHKOFF TIMES".

N (No impact on Not the UE in involved idle mode)

3~20

None

BTS

This parameter must be equal to or greater than 0.6x"CHK Read & ONTIMES Write " and equal to or less than "CHKONT IMES".

N (No impact on Not the UE in involved idle mode)

0~4

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

AU0, AU1, AU2, AU3, None AU4, AU5, AU6, AU7

AU0-0&AU10&AU20&AU30&AU40&AU50&AU60&AU7-0

AU0-0&AU10&AU20&AU30&AU4BTS 0&AU50&AU60&AU7-0

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INSIDE_1 00AH, INSIDE_5 0AH, OUTSIDE _300AH, OUTSIDE None _400AH, OUTSIDE _500AH, OUTSIDE _650AH, OUTSIDE _200AH

INSIDE_50A INSIDE_50A BTS H H

This parameter is valid Read & only when Write "R0BatAll ow" is set to YES.

N (No impact on Not the UE in involved idle mode)

007C, 010C, 015C

None

015C

015C

BTS

This parameter is valid Read & only when Write "R0BatAll ow" is set to YES.

N (No impact on Not the UE in involved idle mode)

INSIDE_B ATTERY, OUTSIDE None _BATTER Y

INSIDE_BAT INSIDE_BAT BTS TERY TERY

This parameter is valid Read & only when Write "R0BatAll ow" is set to YES.

N (No impact on Not the UE in involved idle mode)

AU0, AU1, AU2, AU3, None AU4, AU5, AU6, AU7

AU0-0&AU10&AU20&AU30&AU40&AU50&AU60&AU7-0

AU0-0&AU10&AU20&AU30&AU4BTS 0&AU50&AU60&AU7-0

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INSIDE_1 00AH, INSIDE_5 0AH, OUTSIDE _300AH, OUTSIDE None _400AH, OUTSIDE _500AH, OUTSIDE _650AH, OUTSIDE _200AH

INSIDE_50A INSIDE_50A BTS H H

This parameter is valid Read & only when Write "R1BatAll ow" is set to YES.

N (No impact on Not the UE in involved idle mode)

007C, 010C, 015C

None

015C

015C

BTS

This parameter is valid Read & only when Write "R1BatAll ow" is set to YES.

N (No impact on Not the UE in involved idle mode)

INSIDE_B ATTERY, OUTSIDE None _BATTER Y

INSIDE_BAT INSIDE_BAT BTS TERY TERY

This parameter is valid Read & only when Write "R1BatAll ow" is set to YES.

N (No impact on Not the UE in involved idle mode)

AU0, AU1, AU2, AU3, None AU4, AU5, AU6, AU7

AU0-0&AU10&AU20&AU30&AU40&AU50&AU60&AU7-0

AU0-0&AU10&AU20&AU30&AU4BTS 0&AU50&AU60&AU7-0

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INSIDE_1 00AH, INSIDE_5 0AH, OUTSIDE _300AH, OUTSIDE None _400AH, OUTSIDE _500AH, OUTSIDE _650AH, OUTSIDE _200AH

INSIDE_50A INSIDE_50A BTS H H

This parameter is valid Read & only when Write "R2BatAll ow" is set to YES.

N (No impact on Not the UE in involved idle mode)

007C, 010C, 015C

None

015C

015C

BTS

This parameter is valid Read & only when Write "R2BatAll ow" is set to YES.

N (No impact on Not the UE in involved idle mode)

INSIDE_B ATTERY, OUTSIDE None _BATTER Y

INSIDE_BAT INSIDE_BAT BTS TERY TERY

This parameter is valid Read & only when Write "R2BatAll ow" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

Cell

This parameter is valid only when Read & "GPRS" is Write set to SupportA sInnPcu.

Cell

0~255

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-121~104

dBm

-109

-109

Cell

The value of this parameter must be smaller than "RACH Read & Busy Write Threshold " in the "SET GCELLC CBASIC" command .

N (No impact on Not the UE in involved idle mode)

0~63

dB

16

16

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

5000

5000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-121~104

dBm

-109

-109

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

225

225

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0dB, 2dB, 4dB, 6dB, 8dB, 10dB, dB 12dB, 14dB, no use

2dB

2dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10M, 100M, AUTO

None

100M

100M

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ALG1, ALG2, NONE

None

ALG1

ALG1

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

DISABLE

DISABLE

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

LASTRBP , None APPOINT RBP

None

None

BSC6900 None

Read & Write

Not involved

Not involved

REC_ALL , REC_ER None R, REC_NO N

None

REC_ALL

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~249

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~249

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~249

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INDEPEN DENT, DIVIDING , FOURDIV None ERSITY, MAINDIV ERSITY, NONE

NONE

NONE

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

None

96

96

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Same_Ba nd, None Diff_Band

Diff_Band

Diff_Band

Cell

This parameter is valid when "REASSE N" in the Read & "SET Write GCELLC CBASIC" command is set to YES.

N (No impact on Not the UE in involved idle mode)

0~70

None

50

50

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell. This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

0~70

None

40

40

Cell

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

This parameter is valid only when "IUOTP" in "ADD Read & GCELL" Write is set to Concentri c_cell and "ENIUO" is set to OFF.

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

This parameter is valid only when "IUOTP" in "ADD Read & GCELL" Write is set to Concentri c_cell and "ENIUO" is set to OFF.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

20~99

None

30

30

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

60

60

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

YES, NO None

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~50

ms

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~768

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~95

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00:00~ None 23:59:59

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~3600

600

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

REHOST RIGHTN OW, REHOST None DELAY, REHOST WHEN

REHOSTDE REHOSTDE Cell LAY LAY

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

NO

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, POWERS None HARING, RF_FH

OFF

OFF

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

A, B, NONE

None

NONE

NONE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~250 character None s

None

None

IP route

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1023

None

None

None

NSE

None

Read & Write

Not involved

Not involved

0~65535

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid when Read & "REPEAT Write DLFASET " is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32

None

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~8

None

Cell

None

Read & Write

Cell

0~16

None

Cell

This parameter is valid when "DYNOpe nTrxPowe r" in the Read & "SET Write GCELLB ASICPAR A" command is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

min

BSC

This parameter is valid only when Read & "ResetAl Write mDelayS witch" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~60

min

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~15

min

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~120

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MSLOST, QUALITY BAD, None CELLRES ELECT

None

None

BSC

None

Read & Write

Not involved

Not involved

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~5

PPP link

None

Read & Write

BSC6900

2~5

MP link

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Noneed, Manually, Reset, Normally, Correlativ None e, Configura tion, Expired

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~86400

30

30

BSC

Set when Allow Common Measure ment at Iur-g is Read & set to Yes Write or Allow Info Exchange at Iur-g is set to Yes

N (No impact on Not the UE in involved idle mode)

0~190

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~21

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~100

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

RGPS, GPS

None

GPS

GPS

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

NSE

None

Read & Write

NSE

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, None TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1920~307 20, step: ms 480

52_Times

52_Times

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

STANDA LONETC, MASTERI NPOOLT None C, SLAVEIN POOLTC

STANDALO NETC

STANDALO NETC

BSC

RMTTCA TERTRA NSMODE must be set when "ISTCCE NTRAL" Read & in the Write "ADD SUBRAC K" command is set to YES.

BSC6900

0~4095

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~16, 255 None

255

255

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~16

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~200 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~100

None

None

None

BSC

None

Read & Write

Not involved

Not involved

1~100

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, ENABLE, None UNSUPP ORT

DISABLE

DISABLE

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.48sec, 0.96sec, 1.92sec, 3.84sec, s 7.68sec, 15.36sec, 30.72sec, 61.44sec

15.36sec

15.36sec

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.48sec, 0.96sec, 1.92sec, 3.84sec, s 7.68sec, 15.36sec, 30.72sec, 61.44sec

0.96sec

0.96sec

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

20~99

None

20

20

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES, None NONE

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:0~1 4880, step:480; ms SDCCH:0 ~14570, step:470

Cell

This parameter is valid only when "MEASU RETYPE" Read & in "SET Write GCELLC CUTRAN SYS" is set to EnhMeas Report.

N (No impact on Not the UE in involved idle mode)

TCH:0~1 4880, step:480; ms SDCCH:0 ~14570, step:470

Cell

This parameter is valid only when "MEASU RETYPE" Read & in "SET Write GCELLC CUTRAN SYS" is set to EnhMeas Report.

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

AAL2 path

When the value of "ADDTOR SCGRP" in "ADD Read & AAL2PAT Write H" is set to YES, this parameter is valid.

N (No impact on Not the UE in involved idle mode)

SHARE

None

None

None

Transmis sion None resource group

Read & Write

Not involved

Not involved

SHARE, EXCLUSI None VE

None

None

IP logical None port

Read & Write

Not involved

Not involved

0~255

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

A 3G cell can be added into the candidate cell queue when the following conditions are met: "INTERR ATOUTB SCHOEN " is set to YES; Read & "BET3GH Write OEN" is set to YES; the RSCP of the 3G cell for a period of time is greater than the sun of "HORSC PTH3G" and "RSCPOF

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BASIS_O F_B1, None BASIS_O F_B2

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BASIS_O F_B1, None BASIS_O F_B2 MINUS_5 2db, MINUS_4 8db, MINUS_4 4db, MINUS_4 0db, MINUS_3 6db, MINUS_3 2db, MINUS_2 8db, MINUS_2 4db, MINUS_2 dB 0db, MINUS_1 6db, MINUS_1 2db, MINUS_1 0db, MINUS_8 db, MINUS_6 db, MINUS_4 db, MINUS_2 db, Zerodb, 2db, 4db,

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MINUS_2db MINUS_2db Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

kbit/s

None

None

Transport None channel

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~7

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~64

kbit/s

None

None

Transport None channel

Read & Write

N (No impact on Not the UE in involved idle mode)

2~4094

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~96

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

COMMIS SIONING, UPGRAD None E, RESTOR E

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~127

dB

68

Set this parameter to about 68 in densely populated BSC urban areas and about 72 in suburban areas.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~63 None character

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~50 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

SCCP

When the value of "SPCBIT S" is set Read & to BIT14 Write or BIT24, this parameter is valid.

BSC6900

1~65535

ms

3000

3000

PPP link

None

Read & Write

BTS

0~190

None

Cell

This parameter is valid only when "EMCPRI Read & Write LV" in "SET GCELLC CAD" is not set to

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NONREVERTI VE, None REVERTI VE

None

None

MSP protect group

None

Read & Write

BSC6900

0~429496 None 7295

4294967295 4294967295 SCCP

None

Read & Write

BSC6900

1~5

per cent

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~15

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

12

12

SCTP link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

25

25

SCTP link None

Read & Write

N (No impact on Not the UE in involved idle mode)

500~6000 ms 0

1000

1000

The value to be set should be larger than the value of "RTOMIN Read & SCTP link " in "ADD Write SCTPLN K" but smaller than the value of "RTOMA X". The value to be set should be larger than the Read & SCTP link value of Write "RTOMIN " in "ADD SCTPLN K". The value to be set should be smaller than the Read & SCTP link value of Write "RTOMA X" in "ADD SCTPLN K".

N (No impact on Not the UE in involved idle mode)

500~6000 ms 0

3000

3000

N (No impact on Not the UE in involved idle mode)

500~6000 ms 0

1000

1000

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

DISABLE

DISABLE

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~80

None

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NEXTHO None P, OUTIF

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

1~100

None

IP logical None port

Read & Write

N (No impact on Not the UE in involved idle mode)

0~999

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~300000 kbit/s 0

None

None

IP path

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~400000 kbit/s 0

None

None

When "GRPT" in "ADD RSCGRP " is set to ATM or "BWMOD E" is set to FULL_DU PLEX, this parameter is valid;The Transmis sum of sion Read & "TxBw" resource and Write group "RxBw" in "ADD RSCGRP " of upper class RSCGRP can not less than the "TxBw" and "AllBw" in "ADD RSCGRP "of lower class

N (No impact on Not the UE in involved idle mode)

0~63

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

In dual-band networking mode for densely populated urban areas, the level drops rapidly due to multiple barriers. The propagation loss of the 1800 MHz frequency band is greater than Cell the propagation loss of the 900 MHz frequency band. Considering the preceding factors, you can set this parameter to YES for the DCS1800 cell. Under normal conditions,

This parameter is valid only when Read & "HOCTRL Write SWITCH" is set to HOALGO RITHM1.

N (No impact on Not the UE in involved idle mode)

0~70

None

60

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

42

42

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

41

41

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

50

50

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

49

49

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

48

48

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

47

47

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

46

46

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

45

45

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

44

44

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

43

43

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~249

None

None

None

TRX

None

Read & Write

Not involved

Not involved

0~249

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~249

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

RXUNAM E, None RXUPOS, SRNSN

None

None

TRX

None

Read & Write

Not involved

Not involved

RXUNAM E, None RXUPOS, SRNSN

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

TRX

None

Read & Write

Not involved

Not involved

1~64 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~6

None

None

None

TRX

None

Read & Write

Not involved

Not involved

1~6

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~6

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DRRU, DRFU, MRRU, MRFU, None GRRU, GRFU, BTS3900 E

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

None

None

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

48VDISA BLE, RES0, RES1, RES2, TSDISAB None LED, HSDISAB LED, RES3, RES4

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BT1_DIS ABLE(0), AH_DISA BLE(1), AT1_DIS None ABLE(2), AT2_DIS ABLE(3), BT2_DIS ABLE(4)

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

This parameter is required Read & BSC6900 when Write "Default DPC" is set to NO.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when Read & "PWRBC Write DALLOW D" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~2

None

Cell

This parameter is valid only when "SAICALL Read & OWED" in Write "SET GCELLP WRBASI C" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~4

None

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

T1_DISA BLE, ET_DISA BLE, ET1_DIS None ABLE, ET2_DIS ABLE, T2_DISA BLE

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

Cell

This parameter is valid only when Read & "TURNOF Write FENABLE " is set to YES. This parameter is valid only when Read & "TURNOF Write FENABLE " is set to YES.

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

BYNAME

BYNAME

Cell

N (No impact on Not the UE in involved idle mode)

1~16

None

Cell

1. This parameter is valid only when "TURNOF FENABLE " is set to ENABLE. 2. The setting of this parameter Read & must Write meet the following condition: "SAMECV GCELLL OADSTA TTM" >= "SAMECV GCELLL OADLAS TTM".

N (No impact on Not the UE in involved idle mode)

0~100

per cent

50

50

Cell

This parameter is valid only when Read & "TURNOF Write FENABLE " is set to YES.

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

This parameter is valid only when Read & "TURNOF Write FENABLE " is set to YES.

N (No impact on Not the UE in involved idle mode)

0~30240, ms step: 480

32

32

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

WATER_I MMERSE D, SMOG, None GM_DISA BLE

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

WIDISAB LE, SMDISAB LE, None IMDISAB LE, GMDISAB LE

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

WILOW, SMLOW, None IMLOW, GMLOW,

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

WS_DISA BLE(0), SS_DISA None BLE(1), GS_DISA BLE(2)

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

ADD0dB, ADD10dB None , Automatic

ADD0dB

ADD0dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

38

38

BSC

None

Read & Write

Not involved

Not involved

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid only when "QUICKH Read & OEN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

GERMAN , ENGLISH , ITALIAN, FRENCH, SPANISH , DUTCH, SWEDIS H, DANISH, PORTUG UESE, FINNISH, NORWE GIAN, GREEK, TURKISH None , HUNGAR IAN, POLISH, GB2312, KOI8-R, KOI8-U, KOI8, WINDOW S-1251, ASMO_4 49, WINDOW S-1256, WINDOW S-874, WINDOW

None

ENGLISH

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Valid command string, without None the ';'at the end of the string.

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYBTSID, BYCELLI None D

None

BYCELLID

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~511

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~214748 None 3646

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1199

None

None

None

SCTP link None

Read & Write

Not involved

Not involved

2000-11~203712-31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-11~203712-31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-11~203712-31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

7~90

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1E-3, 1E4, 1E-5, 1E-6, 1E- None 7, 1E-8, 1E-9

1.00E-06

1.00E-06

MSP protect group

None

Read & Write

BSC6900

2000-0101~2050- None 12-31

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~191

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10, step:0.1

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

55

55

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

55

55

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

None

DISABLE

MSP protect group

None

Read & Write

BSC6900

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

ENABLE

ENABLE

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5

None

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

0~255

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

48

48

BSC

None

Read & Write

Not involved

Not involved

HIGH, LOW

None

None

None

MSP protect group

None

Read & Write

Not involved

Not involved

40~70

degree Celsius

53

53

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

35.0~55.6 V (step: 0.1)

None

If "Power System Type" is "SC48200", the recommende d value is BTS "460". Otherwise, the recommende d value is "430".

The value of this parameter must be smaller Read & than "DC Write Voltage Lower Threshold ".

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~63 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NoPriority , Priority4, Priority3, Priority2, None Priority1, Priority0, PriorityB, PriorityA

NoPriority

NoPriority

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NoPriority , Priority4, Priority3, Priority2, None Priority1, Priority0, PriorityB, PriorityA

NoPriority

NoPriority

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~6

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SUPPOR T, None UNSUPP ORT

UNSUPPOR None T

BTS

None

Read & Write

BTS

1000~655 None 35

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~655 None 35

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~17 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

SEPARA TE, None TOGETH ER, AIP

SEPARATE

SEPARATE

BSC

None

Read & Write

BSC6900

TDM, HDLC, None HubBTS, IP

TDM

TDM

BTS

None

Read & Write

BTS

TDM, None HDLC, IP

None

None

BTS

The value range of this parameter varies with "BTS Type". Read & Different Write types of BTSs support different types of services.

BTS

SYSTEM, CONFIG, MAINTAI None N, STAT, ALARM

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OML, RSL, EML, ESL, CSVOICE , CSDATA, None PSHIGHP RI, PSLOWP RI, OTHERD ATA

None

None

BTS

None

Read & Write

Not involved

Not involved

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

1800

1800

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~20 character None s

None

None

BSC

None

Read & Write

Not involved

Not involved

1~10

None

BSC

This parameter is valid when Read & "SGSNP Write OOLALL OW" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~1023

None

BSC

This parameter is valid when Read & "SGSNP Write OOLALL OW" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Release 98 or older, Release 99 onwards

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

UNISTAL L, None ALLOW, DENY

ALLOW

ALLOW

BSC

None

Read & Write

BSC

50~95

per cent

75

75

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

BSC

None

Read & Write

Not involved

Not involved

NO, YES None

NO

NO

BTS

None

Read & Write

Cell

unshielde d, None shielded

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~12

BTS

This parameter is valid only when the cell parameter "BAKPW RSAVME Read & THOD" is Write set to BYPWR and "SDFALG " in "SET GTRXDE V" is set to

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~186

None

None

None

SCCP

None

Read & Write

Not involved

Not involved

0~186

None

None

None

SCCP

None

Read & Write

Not involved

Not involved

0~15

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~255

None

100

100

NSE

None

Read & Write

NSE

0~255

None

100

100

NSE

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~14880, step:480; ms SDCCH:4 70~14570 , step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

None

None

None

None

Read & Write

Not involved

Not involved

TCH:480 ~14880, step:480; ms SDCCH:4 70~14570 , step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

ms

3000

3000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

Ethernet port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

None

None

Read & Write

Not involved

Not involved

0~65535

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

255

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~35

None

None

None

BTS

None

Read & Write

Not involved

Not involved

E1SELFL OOP, None IASUSEL FLOOP

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

B0000, B0001, B0010, B0011, B0100, B0101, B0110, B0111, B1000, B1001, B1010, B1011, B1100, B1101, B1110, B1111

None

B0000

B0000

SCCP

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~600

300

300

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DATE, WEEK, None DATEWE EK

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOTSUP PORT, None INNER, OUTER

None

NOTSUPPO BSC RT

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

OPEN

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

JAN, FEB, MAR, APR, MAY, JUN, JUL, None AUG, SEP, OCT, NOV, DEC

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~2000

None

10

10

None

The number of CPU usage sampling times is at Read & least Write twice the size of "Fast judgemen t window".

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3, 8~27 None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 2, 4, 8, 10, 12, 14, 16, None 18, 20, 22, 24, 26 0, 2, 4, 8, 10, 12, 14, 16, None 18, 20, 22, 24, 26

None

None

Transmis sion None resource group

Read & Write

Not involved

Not involved

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~5, 8~27 None

None

None

E1/T1 link None

Read & Write

Not involved

Not involved

0~5, 8~27 None

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

Transmis sion None resource group

Read & Write

Not involved

Not involved

0~27

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5, 8~27 None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0, 2, 4, 8, 10, 12, 14, 16, None 18, 20, 22, 24, 26

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~27

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

{0~27}

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 2, 4, 8, 10, 12, 14, 16, None 18, 20, 22, 24, 26

None

None

Board

None

Read & Write

Not involved

Not involved

0~27

None

None

None

Transmis sion None resource group

Read & Write

Not involved

Not involved

0~23

None

None

None

BTS

None

Read & Write

BTS

0~27

None

None

None

BTS

None

Read & Write

BTS

0~7

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOCOMB , PBT, WBANDC OMB, DIVERSI TY, None DDIVERS ITY, DPBT, DTIC, NONE

NONE

NONE

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SGL_ANT ENNA, SGLDOU BLE_ANT ENNA, DOUBLE _ANTEN NA, DOUBLE FOUR_A None NTENNA, DOUBLE SINGLE_ ANTENN A, DOUBLE DOUBLE _ANTEN NA

DOUBLE_A NTENNA

DOUBLE_A NTENNA

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SGL_ANT ENNA, SGLDOU BLE_ANT ENNA, DOUBLE _ANTEN NA, DOUBLE FOUR_A None NTENNA, DOUBLE SINGLE_ ANTENN A, DOUBLE DOUBLE _ANTEN NA

DOUBLE_A NTENNA

DOUBLE_A NTENNA

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SGL_ANT ENNA, SGLDOU BLE_ANT ENNA, DOUBLE _ANTEN NA, DOUBLE FOUR_A None NTENNA, DOUBLE SINGLE_ ANTENN A, DOUBLE DOUBLE _ANTEN NA

DOUBLE_A NTENNA

DOUBLE_A NTENNA

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SGL_ANT ENNA, SGLDOU BLE_ANT ENNA, DOUBLE _ANTEN NA, DOUBLE FOUR_A None NTENNA, DOUBLE SINGLE_ ANTENN A, DOUBLE DOUBLE _ANTEN NA

DOUBLE_A NTENNA

DOUBLE_A NTENNA

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SGL_ANT ENNA, DOUBLE SINGLE_ ANTENN None A, DOUBLE DOUBLE _ANTEN NA

SGL_ANTEN SGL_ANTEN BTS NA NA

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~16383( BIT14), 1~65535( None BIT16), 1~167772 15(BIT24)

None

None

SCCP

When the value of "SPDF" is Read & set to Write WNF, this parameter is valid.

BSC6900

BIT14, BIT16, BIT24

None

None

None

SCCP

This parameter depends Read & on Write network planning.

BSC6900

1~11 character None s

None

None

SCCP

When the value of "SPDF" is Read & set to Write DNF, this parameter is valid.

Not involved

Not involved

0~65535

None

None

None

PBE1T1

None

Read & Write

N (No impact on Not the UE in involved idle mode)

WNF, DNF

None

WNF

WNF

SCCP

When the value of "SPDF" in "ADD Read & N7DPC" Write is set to WNF, this parameter is valid.

N (No impact on Not the UE in involved idle mode)

L11_FOR BID, L12_FOR BID, L13_FOR None BID, L14_FOR BID, L15_FOR BID

L11_FORBID- L11_FORBID0&L12_FOR 0&L12_FOR BIDBID0&L13_FOR 0&L13_FOR BIDBIDCell 0&L14_FOR 0&L14_FOR BIDBID0&L15_FOR 0&L15_FOR BID-0 BID-0

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ET_DISA BLE0, ET_DISA BLE1, SMDISAB LE, WIDISAB None LE, GMDISAB LE, ARREST ER1, ARREST ER2

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SMDISAB LE, WIDISAB LE, GMDISAB None LE, ARREST ER1, ARREST ER2

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~12, step: 5

min

12

12

BSC

None

Read & Write

Not involved

Not involved

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PSMODE, VGCSMO None DE

PSMODE

PSMODE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PSMODE, VGCSMO None DE

PSMODE

PSMODE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FR, EFR

None

FR

FR

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000M, AUTO

None

None

AUTO

Ethernet port

None

Read & Write

BSC6900

0~63

dB

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOTSPP RTBC, SPPRTS TANDAR None D, SPPRTSI MPLE

NOTSPPRT NOTSPPRT BSC BC BC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

UNSUPP ORT, None SUPPOR T

UNSUPPOR None T

Cell

This parameter is valid only when Read & "GPRS" is Write set to SupportA sInnPcu.

N (No impact on Not the UE in involved idle mode)

UNSUPP ORT, None SUPPOR T

UNSUPPOR None T

Cell

This parameter is valid only when Read & "GPRS" is Write set to SupportA sInnPcu.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

This parameter is required Read & BSC6900 when Write "Trunking MSC" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

This parameter is valid only when "TYPE" in Read & "SET Write BSCPCU TYPE" is set to OUTER.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

This parameter is valid only when "TYPE" in Read & "SET Write BSCPCU TYPE" is set to OUTER.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

This parameter is valid only when "TYPE" in Read & "SET Write BSCPCU TYPE" is set to OUTER.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

This parameter is valid only when "TYPE" in Read & "SET Write BSCPCU TYPE" is set to OUTER.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

UNSUPP ORT, None SUPPOR T

UNSUPPOR None T

Cell

This parameter is valid only when Read & "GPRS" is Write set to SupportA sInnPcu.

Cell

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

YES, NO None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~4

None

None

None

SCCP

None

Read & Write

Not involved

Not involved

SUPPOR T, None NOT_SU PPORT

If the version of a GSM base station is BTS3000V10 0R009 or later, or if the version of a multi-mode 3900 series base station is V100R002 NOT_SUPP or later, the BTS ORT recommende d value of this parameter is SUPPORT. Otherwise, the recommende d value of this parameter is NOT_SUPP ORT.

None

Read & Write

BTS

SUPPOR T, None NOT_SU PPORT

None

If the software version of the SingleRAN BTS is SRAN3.0 or later, the parameter Is support SRAN mode needs to be set to SUPPORT(S upport). If the BTS software version of the SingleRAN BTS is earlier than SRAN3.0, the parameter Is support SRAN mode needs to be set to NOT_SUPP ORT(Not

None

Read & Write

BTS

SUPPOR T, None NOT_SU PPORT

NOT_SUPP NOT_SUPP ORT ORT

BTS

None

Read & Write

BTS

0~2047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~100 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~4

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~4

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HOALGO RITHM1, None HOALGO RITHM2

HOALGORIT HOALGORIT Cell HM1 HM1

The value of this parameter must be the same Read & as that of Write "HOCTRL SWITCH" in "SET GCELLH OBASIC". Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

Current BFD session

None

Not involved

Not involved

1~65533, None 65535

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~3 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~1000

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

1~3 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

E1/T1 port

None

Read & Write

Not involved

Not involved

BITS12MHZ, BITS22MHZ, BITS12MBPS, BITS22MBPS, GPS, None 8KHZ, LINE1_8K HZ, LINE2_8K HZ, BITS1T1BPS, BITS2T1BPS

None

LINE1_8K and LINE2_8K are most commonly used.

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, None TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

E1/T1 port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~11

None

None

None

None

None

Read & Write

Not involved

Not involved

0~11

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~11

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~11

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~11

None

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

BSC6900 None

Read & Write

Not Invovled

Not Invovled

0~11

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~11

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

BSC

None

Read & Write

Not involved

Not involved

0~11

None

None

None

BSC

None

Read & Write

Not involved

Not involved

0~254

None

None

None

BTS

None

Read & Write

BTS

0~11

None

None

None

BTS

None

Read & Write

BTS

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

Control None plane link

Read & Write

Subrack connectio n path

0~11

None

None

None

BSC6900 None

Read & Write

Subrack connectio n path

1~249 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MPS, None EPS, TCS

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DES, ASC

None

DES

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

100

100

NSE

None

Read & Write

NSE

0~255

None

100

100

NSE

None

Read & Write

N (No impact on Not the UE in involved idle mode)

GSM_PRI OR, None UMTS_P RIOR

GSM_PRIOR GSM_PRIOR BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CSVOICE , CSDATA, PSHIGHP None RI, PSLOWP RI

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

63

63

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

20~99

per cent

75

75

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

85

85

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

20~99

per cent

80

80

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

85

80

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~15360, step:480; ms SDCCH:4 70~15040 , step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~15360, step:480; ms SDCCH:4 70~15040 , step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~214748 None 3646

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

63

63

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HOUR, None MIN, SEC

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-1-1 00:00:00~ 2037-12- None 31 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-1-1 00:00:00~ 2037-12- None 31 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00:00~ None 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00:00~ None 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1970-1-1 00:00:00~ 2538-12- None 31 23:59:59

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

When the value of "OPMOD E" of "BLK ACIC" is Read & E1/T1 link BYCICRA Write NGE, the value of STARTTS needs to be set.

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

PBCIC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31

None

None

None

BSC

The setting of this parameter must meet the following condition: When "EndMont hDSTPA" Read & and Write "StartMon thDSTPA" are set to the same value, "EndDay DSTPA" must be later than "StartDay DSTPA".

N (No impact on Not the UE in involved idle mode)

degree 99.0~40.0 Celsius (step: 0.1)

-100

-100

BTS

The value of this parameter must be smaller Read & than Write "Heater shutdown Temperat ure".

N (No impact on Not the UE in involved idle mode)

JAN, FEB, MAR, APR, MAY, JUN, JUL, None AUG, SEP, OCT, NOV, DEC

None

None

BSC

The setting of this parameter must meet the following condition: Read & "EndMont Write hDSTPA" is the same as or is later than "StartMon thDSTPA"

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 2, 4, 6

None

None

None

BTS

None

Read & Write

BTS

60~600

240

240

BTS

This parameter is valid Read & only when Write "ENABLE " is set to YES.

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

None

None

BSC

This parameter is set only when Read & "BSCDyn Write SwitchTrx PAAllow" is set to YES.

N (No impact on Not the UE in involved idle mode)

8~255

None

None

None

When the value of "OPMOD E" of "BLK ATERE1T Read & E1/T1 link 1" is Write BYCICRA NGE, the value of STARTTS needs to be set.

N (No impact on Not the UE in involved idle mode)

1~31, step:8

None

None

None

When the value of "OPMOD E" of "BLK AE1T1" is Read & E1/T1 link BYCICRA Write NGE, the value of STARTTS needs to be set.

N (No impact on Not the UE in involved idle mode)

1~31

None

None

None

BTS

None

Read & Write

BTS

DISABLE D, None ENABLE D

ENABLED

ENABLED

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE D, None ENABLE D

DISABLED

DISABLED

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

E1/T1 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000-11~203712-31

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32

None

None

None

BSC

To ensure that all the frequenci es can be measured within 24 hours, the following condition Read & must be Write met: ("PERIOD " x 15) x (total number of frequenci es to be measured /"STEP") < (24 x Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

MTP3 link None

Not involved

Not involved

00:00:00~ None 23:59:59

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

60~300

120

120

BTS

This parameter is valid Read & only when Write "ENABLE " is set to YES.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

SCCP

None

Read & Write

Not involved

Not involved

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HOUR{0~ 23}, MIN{0~59 None }, SEC{0~5 9}

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

BTS

If the added monitorin g timeslot works at 64 kbit/s, the subtimeslots are numbered from 0. If the added monitorin g timeslot works at 32 kbit/s, the sub- Read & timeslots Write are numbered from 0 or 4. If the added monitorin g timeslot works at 16 kbit/s, the subtimeslots are numbered from 0, 2, 4, or 6. If the added

N (No impact on Not the UE in involved idle mode)

00:00:00~ None 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BTS30, BTS312, BTS3001 C, BTS3001 CP, BTS3002 C, BTS3012 A, BTS3006 A, BTS3012, BTS3006 C, BTS3002 E, None BTS3012 AE, BTS3012 _II, BTS3900 _GSM, BTS3900 A_GSM, BTS3036, BTS3036 A, BTS3900 L_GSM, BTS3900 B_GSM, BTS3900 E_GSM

None

None

BTS

If "Work Mode for Auto Download Activation " is "TMUAUT Read & OACT", Write the BTS type must be consistent with the actual BTS type.

N (No impact on Not the UE in involved idle mode)

1~15

None

None

None

When SUBBSC is selected Read & E1/T1 link for "BSC Write flag", this parameter should be set. When SUBBSC is selected Read & E1/T1 link for "BSC Write flag", this parameter should be set.

N (No impact on Not the UE in involved idle mode)

1~15

None

None

None

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

16~1023

byte

352

352

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

16~1023

byte

352

352

BTS

This parameter must meet the following requireme nts: The sum of the value of "Max Read & Subframe Write Length" and 8 must be smaller than the value of "Maximu m Frame Length".

N (No impact on Not the UE in involved idle mode)

1~50

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~124, 128~189

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

NO, YES None

NO

NO

Cell

This parameter is valid when "FLEXABI SMODE" Read & in the Write "MOD BTS" command is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 2, 4, 6

None

None

None

BTS

None

Read & Write

BTS

0~65535

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOTSUP PORT, None SUPPOR T

NOTSUPPO NOTSUPPO BSC RT RT

None

Read & Write

N (No impact on Not the UE in involved idle mode)

UNSUPP ORT, None SUPPOR T

UNSUPPOR None T

Cell

This parameter is valid only when "GPRS" is set to SupportA sInnPcu. If "Cell Extension Type" in the "ADD GCELL" command Read & or "MOD Write GCELL" command is set to "Double Timeslot Extension Cell" for a cell, the parameter cannot be set to "SUPPOR T".

Cell

NOTSUP PORT, None SUPPOR T

NOTSUPPO NOTSUPPO BSC RT RT

None

Read & Write

N (No impact on Not the UE in involved idle mode)

UNSUPP ORT, None SUPPOR T

UNSUPPOR None T

Cell

This parameter is valid only when "GPRS" is set to SupportA Read & sInnPcu Write and "SUPPOR TDTM" is set to SUPPOR T.

Cell

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

Not involved

Not involved

T_12, T_15, T_20, T_30, T_41, T_55, T_76, T_109, T_163, T_217

None

T_20

T_20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

NSE

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

NSE

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

CLOSE

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

BSC6900 None

Read & Write

Not involved

Not involved

CLOSE, OPEN

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SUN, MON, TUE, None WED, THU, FRI, SAT

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

BFD_OFF , None BFD_ON

None

None

None

None

Read & Write

Not involved

Not involved

NO, YES None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

None

CLOSE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

SCTP link None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~254

None

10

10

SCTP link None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

3~5

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

FIRST, SECOND, THIRD, None FOURTH, LAST

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2500

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

SyncCase 1, None SyncCase 2

None

None

Cell

This parameter is valid only when Read & "UTRANC Write ELLTYPE " is set to TDD.

N (No impact on Not the UE in involved idle mode)

AISS, GPS

None

AISS

AISS

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CONSYN, INTERSY None N

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~7

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~59

min

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~250 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~250 character None s

MBSC

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 8~11

None

10

10

Cell

This parameter is valid only when "LOADHO Read & EN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~250 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~250 character None s

BSC

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~250 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~300 ms 00

3000

3000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30000~60 ms 000

60000

60000

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

800~1500 ms

1500

1500

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

800~1500 ms

1500

1500

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

2000~300 ms 0

3000

3000

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

800~1500 ms

1500

1500

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

800~1200 ms

1200

1200

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~120 ms 000

3000

3000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

60~2400 ms (step: 10)

12

When the transmission quality is good, the recommende d settings are as follows: "Ring II Wait Time Before Switch" = 0; "Ring II Try Rotating Duration Time" = 60; "Ring II Rotating Penalty BTS Time" = 0; "T200" = 12; "T203" = 1; and "N200" = 3. When the transmission quality is bad, the recommende d settings are as follows: "Ring II Wait Time Before Switch" = 30; "Ring II Try Rotating

The value of this parameter Read & must be Write smaller than "T203".

N (No impact on Not the UE in involved idle mode)

5~1275, step: 5

ms

50

50

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~1275, step: 5

ms

50

50

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~2550, ms step: 10

200

200

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~2550, ms step: 10

60

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~2550, ms step: 10

150

150

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~1275, step: 5

ms

60

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~1275, step: 5

ms

60

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

When the transmission quality is good, the recommende d settings are as follows: "Ring II Wait Time Before Switch" = 0; "Ring II Try Rotating Duration Time" = 60; "Ring II Rotating Penalty BTS Time" = 0; "T200" = 12; "T203" = 1; and "N200" = 3. When the transmission quality is bad, the recommende d settings are as follows: "Ring II Wait Time Before Switch" = 30; "Ring II Try Rotating

The value of this parameter Read & must be Write greater than "T200".

N (No impact on Not the UE in involved idle mode)

180000~3 ms 60000

360000

360000

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

180000~3 ms 60000

360000

360000

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

1400~200 ms 0

2000

2000

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~100 ms 00

10000

10000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

None

The value of this parameter must be Read & smaller Write than or equal to "Time2[S] ".

N (No impact on Not the UE in involved idle mode)

0~2550, step:10

ms

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

500ms, 1000ms, 1500ms, 2000ms, 2500ms, 3000ms, 3500ms, 4000ms

ms

500ms

500ms

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0ms, 80ms, 120ms, 160ms, 200ms, 500ms, 1000ms, 1500ms

ms

500ms

500ms

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1530, step: 6

min

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~30

10

10

BC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

800~1200 ms

1200

1200

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~100 ms 00

5000

5000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

800~1200 ms

1200

1200

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~300 ms 00

1000

1000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

800~1200 ms

1200

1200

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~100 ms 00

3000

3000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1000~100 ms 00

3000

3000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

800~1200 ms

1200

1200

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~14880, step:480; ms SDCCH:4 70~14570 , step:470

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

bit

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

0.5~8, step:0.5

Cell

This parameter is valid only when "HOCTRL SWITCH" is set to HOALGO RITHM2 and Read & "TAHOEN Write " is set to YES. The following condition must be met: "TASTAT TIME" >= "TALAST TIME".

N (No impact on Not the UE in involved idle mode)

0~255

bit

255

255

Cell

This parameter is valid only when "TAHOEN Read & " in "SET Write GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~255

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~14880, step:480; ms SDCCH:4 70~14570 , step:470

Cell

This parameter is valid only when "HOCTRL SWITCH" Read & in "SET Write GCELLH OBASIC" is set to HOALGO RITHM2.

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.5~0.8, step:0.5

Cell

This parameter is valid only when "TAHOEN " is set to YES and "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2. The following condition must be met: "TASTAT TIME" >= "TALAST TIME".

N (No impact on Not the UE in involved idle mode)

0~255

bit

63

63

Cell

This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentri Read & c_cell. Write The following condition must be met: "TALIMIT" > "TATHRE S".

N (No impact on Not the UE in involved idle mode)

0~25

None

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~25

None

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~12

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~12

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~300

90

90

BTS

This parameter is valid Read & only when Write "OMLBKU P" is set to YES.

N (No impact on Not the UE in involved idle mode)

60~300

90

90

BTS

This parameter must meet the following requireme nts: "FallBack Start Read & Time" > Write "Ring I Wait Time Before Switch" + "Ring I Try Rotating Duration Time".

N (No impact on Not the UE in involved idle mode)

1~254

None

170

170

MTP3 link None

Read & Write

BSC6900

1000~100 ms 00

4000

4000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~500

mV

80

80

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

ON

ON

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

60

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

per mill

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

55

55

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

per mill

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

55

55

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10

None

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~600

60

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

60

60

Cell

"TCHTRI CBUSYO VERLAYT HR" and "TCHTRI BUSYUN DERLAYT Read & HR" can Write be set only when "HRIUOL DRATES ELALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~100

per cent

70

70

Cell

"TCHTRI CBUSYO VERLAYT HR" and "TCHTRI BUSYUN DERLAYT Read & HR" can Write be set only when "HRIUOL DRATES ELALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~15

None

10

10

MTP3 link None

Read & Write

BSC6900

SEPERA TE_PRIN CIPAL, SEPERA TE_SUB ORDINAT E, None TOGETH ER, SEPERA TE_BSC_ INTERFA CE

None

None

MTP3 link None

Read & Write

Not involved

Not involved

DISABLE, None ENABLE

None

DISABLE

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~335

None

None

None

Control None plane link

Read & Write

Not involved

Not involved

0~4095

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5, 8~27 None

None

None

Control None plane link

Read & Write

Not involved

Not involved

0~11

None

None

None

Control None plane link

Read & Write

Not involved

Not involved

GTC, None UTC, ITC

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

AUTO, Manual

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

AUTO, Manual

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~42, step: 6

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Negative infinity, dB 28~28, step: 4

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~36, Positive infinity, step: 6

dB

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~16383

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~127

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~127

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

20

20

BSC6900 None

Read & Write

Not involved

Not involved

0~100

per cent

15

15

BSC6900 None

Read & Write

Not involved

Not involved

0~5

None

None

None

Control None plane link

Read & Write

Subrack connectio n path

0~5

None

None

None

Control None plane link

Read & Write

Subrack connectio n path

0~127

None

63

63

PBSL

None

Read & Write

BSC

CLOSE, OPEN

None

OPEN

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 degree character Celsius s

45

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 degree character Celsius s

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

50.0~100. degree 0 (step: Celsius 0.1)

500

500

BTS

This parameter must be at least 3C Read & greater Write than "Lower ENV TEMP Alarm".

N (No impact on Not the UE in involved idle mode)

49.0~100. degree 0 (step: Celsius 0.1)

500

500

BTS

This parameter must be at least 4C Read & greater Write than "Lower ENV TEMP Alarm".

N (No impact on Not the UE in involved idle mode)

50.0~100. degree 0 (step: Celsius 0.1)

BTS

This parameter must be at least 3C lower Read & than Write "Upper ENV TEMP Alarm".

N (No impact on Not the UE in involved idle mode)

degree 50.0~99.0 Celsius (step: 0.1)

BTS

This parameter must be at least 4C lower Read & than Write "Upper ENV TEMP Alarm".

N (No impact on Not the UE in involved idle mode)

0.0~500.0 mV (step: 0.1)

800

800

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~65535

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

32768~65 None 535

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

50~70

degree Celsius

65

65

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-40.0~0.0 degree (step: 0.1) Celsius

-100

For EPS4815 boards, the value of this parameter is always "-1". For other BTS types of APMU boards, the recommende d value is "100".

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-40.0~0.0 degree (step: 0.1) Celsius

-100

-100

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

30

30

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~615 character s(GB2312 , KOI8-R, KOI8-U, KOI8, WINDOW S-1251, ASMO_4 49, WINDOW S-1256, WINDOW S-874, WINDOW S-1253, WINDOW None S-1254, WINDOW S-1255, WINDOW S-1257, WINDOW S-1250, WINDOW S-1252, UCS2), 1~2462 character s(BINARY ), 1~1395 character s(others)

None

None

Cell

The maximum length of this parameter is decided by "SCHEM E": When "SCHEM E" is set to BINARY, the length Read & of this Write parameter should not extend 2462 bytes; otherwise, the length should not extend 1395 bytes.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1023

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

65535

65535

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ACTIVE, STANDB None Y

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0.0.0.0~2 55.255.25 None 5.255

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5, 8~27 None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

5000~600 ms 00

5000

5000

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

220~280

264

264

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

220~280

264

264

BTS

None

Read & Write

Not involved

1~10

None

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PERCEN TAGE, None BANDWI DTH

None

None

BSC6900 None

Read & Write

Not involved

Not involved

1~15

min

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

This parameter is valid only when "TIGHTB CCHSWI Read & TCH" in Write "SET GCELLC HMGBASI C" is set to ON.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "TIGHTB CCHSWI Read & TCH" in Write "SET GCELLC HMGBASI C" is set to ON.

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "TIGHTB CCHSWI TCH" in "SET GCELLC HMGBASI C" is set to ON. Read & The Write following condition must be met: "TIGHTB CCHHOS TATTIME " >= "TIGHTB CCHHOL ASTTIME ".

N (No impact on Not the UE in involved idle mode)

0~100

per cent

80

80

Cell

This parameter is valid only when "TIGHTB CCHSWI Read & TCH" in Write "SET GCELLC HMGBASI C" is set to ON.

N (No impact on Not the UE in involved idle mode)

0.5~16, step:0.5

Cell

This parameter is valid only when "TIGHTB CCHSWI TCH" in "SET GCELLC HMGBASI C" is set to ON. Read & The Write following condition must be met: "TIGHTB CCHHOS TATTIME " >= "TIGHTB CCHHOL ASTTIME ".

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "TIGHTB CCHSWI Read & TCH" in Write "SET GCELLC HMGBASI C" is set to ON.

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

3~15

BSC

This parameter is valid when Read & "MSCPO Write OLALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

NOLIMIT, None LIMIT

NOLIMIT

NOLIMIT

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00:00~ None 23:59:59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0, 5~1440 min

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

10

10

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

200~1000 ms 0

2000

2000

Ethernet port

None

Read & Write

Not involved

Not involved

1~65535

ms

3000

3000

None

None

Read & Write

Not involved

Not involved

1~3

Ethernet port

None

Read & Write

Not involved

Not involved

1~10

Ethernet port

None

Read & Write

Not involved

Not involved

1~20

ms

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~1024

None

Ethernet port

None

Read & Write

Not involved

Not involved

NO, YES, None NULL

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~255

40

40

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

1~30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~15

min

BSC

This parameter is valid when Read & "MSCPO Write OLALLO W" is set to YES.

N (No impact on Not the UE in involved idle mode)

7~365

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7295

None

None

This parameter is valid Subsyste Read & only when m Write "IDXTYPE " is set to BYTLLI.

Not involved

Not involved

-99~70

degree Celsius

45

45

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-19~5

degree Celsius

-19

If "Power System Type" is "EPS4815", the recommende d value is BTS "0". For other types of Power System, the recommende d value is "19".

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-99~99

degree Celsius

-20

-20

BTS

The value of this parameter must be at least two degrees Read & smaller Write than "Tempera ture Alarm Upper Threshold ".

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

14~163

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~163

None

None

None

None

The TRMMAP index is configure Read & d by Write setting the value of "TMI" in "ADD TRMMAP

N (No impact on Not the UE in involved idle mode)

1~120

min

None

None

BC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NON_FD None R, FDR

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2~4

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~429496 None 7294

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

8000~120 ms 00

12000

12000

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

30000~90 ms 000

60000

60000

MTP3 link None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~276

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

TRRS, SATEL

None

TRRS

TRRS

ATERCO None NSL

Read & Write

N (No impact on Not the UE in involved idle mode)

TRRS, SATEL

None

None

None

PBE1T1

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-120~-1, 1~120

min

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~62

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NORMAL, None FORMAT

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~5

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

60

60

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

60

67

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

50

50

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

30~100

per cent

50

62

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ON, OFF None

ON

ON

Board

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~255

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

M3UA_O VERRIDE _MOD, None M3UA_L OADSHA RE_MOD

M3UA_LOA M3UA_LOA DSHARE_M DSHARE_M SCCP OD OD

None

Read & Write

Not involved

Not involved

TER_TRA NS, SAT_TRA NS, None TER_AN D_SAT_T RANS

None

None

BTS

None

Read & Write

BTS

0~27

None

None

None

BSC

None

Read & Write

Not involved

Not involved

IP

None

None

None

IP path

None

Read & Write

Not involved

Not involved

IP, HDLC None

None

None

When the value of "ITFT" in "ADD TRMMAP Read & BSC6900 " is set to Write IUB, IUR or IUCS, this parameter is valid.

Not involved

Not involved

IP, HDLC, None TDM

None

None

When the value of "ITFT" in "ADD TRMMAP Read & BSC6900 " is set to Write IUB, IUR or IUCS, this parameter is valid. BSC6900 None Read & Write

Not involved

Not involved

IP, HDLC, None TDM

None

None

Not involved

Not involved

HDLC IP

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ENABLE, h DISABLE

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5sec, 10sec, 15sec, 20sec, 30sec, 60sec, 120sec, 300sec, no use

10sec

10sec

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

None

90

90

Cell

This parameter is valid only when "LOADHO Read & EN" in Write "SET GCELLH OBASIC" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7(FG2a ), 0~1(GOU a), None 0~11(FG2 c), 0~3(GOU c)

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0~5, 8~27 None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~7(FG2a ), 0~1(GOU a), None 0~11(FG2 c), 0~3(GOU c)

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

0~163

None

None

None

BSC6900 None

Read & Write

Not involved

Not involved

0~199

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~199

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~199

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~199

None

PPP link

None

Read & Write

Not involved

Not involved

0~199

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~199

None

IP logical None port

Read & Write

Not involved

Not involved

0~199

None

None

None

The TRM load threshold parameter must meet the following conditions : forward congestio Read & n Write recovery threshold < logical port bandwidth , backward congestio n recovery

N (No impact on Not the UE in involved idle mode)

OFF, ON None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~11

None

None

None

IP logical None port

Read & Write

Not involved

Not involved

0~11

None

None

None

None

None

Read & Write

Not involved

Not involved

0~11

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

TRXAid_ NotAllow, AllowReF orbid, None AllowReI mmed, AllowReC heckRes

AllowReChec AllowReChec Cell kRes kRes

None

Read & Write

N (No impact on Not the UE in involved idle mode)

5~10

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63, 255 None

255

255

Physical channel

None

Read & Write

If traffic handover fails after the modificati on of the Cell parameter , the service is interrupte d.

0~3071

None

None

None

TRX

None

Read & Write

Not involved

Not involved

0~3071

None

None

None

BTS

None

Read & Write

BTS

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3071

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~120 character None s

None

None

BSC

None

Read & Write

Cell

0~3071

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

None

None

None

Physical channel

None

Read & Write

N (No impact on the UE in Cell idle mode)

0~71

None

None

None

TRX

None

Read & Write

Not involved

Not involved

0~8

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

None

None

TRX

None

Read & Write

Not involved

Not involved

0~7

None

None

None

TRX

None

Read & Write

Not involved

Not involved

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TRX, TRU, QTRU, DRRU, DRFU, MRRU, MRFU, None GRFU, GRRU, BTS3900 B, BTS3900 E

None

None

TRX

None

Read & Write

Not involved

Not involved

8~255

None

None

None

When the value of "OPMOD E" of "BLK ATERE1T Read & E1/T1 link 1" is Write BYCICVA LUE, the value of TS needs to be set.

N (No impact on Not the UE in involved idle mode)

1~31, step:8

None

None

None

When the value of "OPMOD E" of "BLK Read & E1/T1 link AE1T1" is Write BYCICVA LUE, the value of TS needs to be set.

N (No impact on Not the UE in involved idle mode)

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, None TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

Cell

None

Read & Write

Cell

2~429496 None 7294

None

None

BC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31

None

None

None

BTS

None

Read & Write

BTS

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, None TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, None TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

PPP link

None

Read & Write

Not involved

Not involved

None

None

MP link

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, None TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

BTS

None

Read & Write

PPP link

0~7

None

None

None

Cell

None

Read & Write

Cell

0~512

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

None

None

None

E1/T1 port

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~1440 min (step: 10)

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~127

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~50 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, None TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, None TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

None

BTS

None

Read & Write

BTS

0~23

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~31

None

None

None

PBSL

None

Read & Write

BSC

0~7

None

Physical channel

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~50

20

If the board is configured with two to four TRXs, the recommende d value of this parameter is 20. If the board is configured TRX with five TRXs, the recommende d value of this parameter is 50. If the board is configured with six TRXs, the

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~65535

ms

5000

5000

BSC

The value of "Fast Flux Measure ment Period" cannot be Read & greater Write than that of "Fast Flux Measure ment TBF Time".

N (No impact on Not the UE in involved idle mode)

Close, Open

None

Open

Open

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

8K, 16K, kbit/s 32K, 64K

None

None

BTS

If this parameter is set to "16K", "InBSC Sub Timeslot No." and "Out-BTS Sub Timeslot No." must be 0, 2, 4, or 6. If this parameter is set to "32K", "In- Read & BSC Sub Write Timeslot No." and "Out-BTS Sub Timeslot No." must be 0 or 4. If this parameter is set to "64K", "InBSC Sub Timeslot No." and "Out-BTS Sub

N (No impact on Not the UE in involved idle mode)

0~254

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TRXLOO PBACK, CHLLOO PBACK, None CHLCOD EC, CPRILOO PBACK

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~31

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SIMPLET EST, None MANUAL TEST

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

PIM

None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CHAIN, RING

None

None

None

BTS

None

Read & Write

Not involved

Not involved

1~255

None

64

64

Ethernet port

None

Read & Write

Not involved

Not involved

1~128

64

64

Ethernet port

None

Read & Write

Not involved

Not involved

0~8

None

Cell

This parameter is valid only when Read & "TURNOF Write FENABLE " is set to ENABLE.

N (No impact on Not the UE in involved idle mode)

00:00~23: None 59

0:00

None

Cell

00:00~23: None 59

0:00

None

Cell

When "TURNOF FCELLST PTIME" < "TURNOF FCELLST RTIME", it indicates that the Dynamic Cell Power Off feature can be enabled for more than a This parameter is valid only when "TURNOF FENABLE " is set to ENABLE or SLEEPIN G. The following condition must be met: "TURNOF FCELLST PTIME" < "TURNOF FCELLST RTIME"..

Read & Write

N (No impact on Not the UE in involved idle mode)

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, ENABLE, None SLEEPIN G

None

DISABLE

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100

per cent

80

80

Cell

This parameter is valid only when Read & "TURNOF Write FENABLE " is set to ENABLE.

N (No impact on Not the UE in involved idle mode)

40~79

degree Celsius

50

50

BTS

The value of this parameter must be smaller than Read & "Tempera Write ture Alarm Lower Threshold ".

N (No impact on Not the UE in involved idle mode)

-99~99

degree Celsius

68

68

BTS

The value of this parameter must be at least two degrees Read & greater Write than "Tempera ture Alarm Lower Threshold ".

N (No impact on Not the UE in involved idle mode)

1~60

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

10

10

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

10

10

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

min

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~60

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

TX_3, TX_4, TX_5, TX_6, TX_7, TX_8, TX_9, TX_10, TX_11, TX_12, TX_14, TX_16, TX_20, TX_25, TX_32, TX_50

None

TX_32

TX_32

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100 (step: 0.01)

Board

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100 (step: 0.01)

Board

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100 (step: 0.01)

Board

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100 (step: 0.01)

Board

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100 (step: 0.01)

Board

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100 (step: 0.01)

Board

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100 (step: 0.01)

Board

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

0~100 (step: 0.01)

Board

None.

Read & Write

N (No impact on Not the UE in involved idle mode)

1~300000 kbit/s 0

None

None

IP path

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~400000 kbit/s 0

None

None

When "GRPT" in "ADD RSCGRP " is set to ATM or "BWMOD E" is set to FULL_DU PLEX, this parameter is valid;The Transmis sum of sion Read & "TxBw" resource and Write group "RxBw" in "ADD RSCGRP " of upper class RSCGRP can not less than the "TxBw" and "AllBw" in "ADD RSCGRP "of lower class Ethernet port Read & Write

N (No impact on Not the UE in involved idle mode)

200~1000 ms 0

500

500

None

Not involved

Not involved

T_2, T_3, T_4, T_5, T_6, T_7, T_8, T_9, T_10, T_12, None T_14, T_16, T_20, T_25, T_32, T_50

T_20

T_20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

EPS, TCS None

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

ANY_ER R_RETU RN, None ALL_END _RETUR N

None

ANY_ERR_R BSC6900 None ETURN

Read & Write

N (No impact on Not the UE in involved idle mode)

GSM900, DCS1800 , GSM900_ DCS1800 , None GSM850, PCS1900, GSM850_ 1800, GSM850_ 1900

None

None

Cell

None

Read & Write

Not involved

Not involved

OUTER, INNER

None

INNER

None

BSC

None

Read & Write

BSC

GSM900, DCS1800 , None GSM850, PCS1900

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BTS30, BTS312, BTS3001 C, BTS3001 CP, BTS3002 C, BTS3012 A, BTS3006 A, BTS3012, BTS3006 C, BTS3002 E, None BTS3012 AE, BTS3012 _II, DBS3900 _GSM, BTS3900 _GSM, BTS3900 A_GSM, DBS3036, BTS3036, BTS3036 A, BTS3900 B_GSM, BTS3900

None

None

BTS

The value range of this parameter varies with BTS type. Read & Different Write types of BTSs support different types of cabinets.

N (No impact on Not the UE in involved idle mode)

GSM900, None DCS1800

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1, 2, 3, 4, 5, 6, 7, 8, None 9, 10, 11, 12

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1, 255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23, 255 None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~53, 255 None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1, 2, 3, 4, 5, 6, 7, 8, None 9, 10, 11, 12

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1, 255

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~23, 255 None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~53, 255 None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

15

15

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

15

15

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

13

13

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

13

13

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

10

10

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

15

15

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

15

15

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

13

13

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

13

13

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

OFF, ON None

OFF

OFF

MSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NORTPC OMP, None RTPCOM P

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NORTPC OMP, None RTPCOM P

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1214~200 1, 2005~378 3, None 3786~478 3, 4785~650 00

None

None

NSE

None

Read & Write

Not involved

Not involved

0~65535

None

None

None

NSE

None

Read & Write

NSE

Administr ators, Operators None , Users, Guests, Customs

Guests

Guests

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~99

None

80

80

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

None

64

64

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

300~1000 ms

1000

1000

E1/T1 port

None

Read & Write

Not involved

Not involved

0~9 Character None s

90

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~8 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~122400, step:480; SDCCH:4 ms 70~11985 0, step:470

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

1~30

dB

14

14

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "ULAFSR EXQUAL HIGHTHR ED" >= "ULAFSR EXQUAL LOWTHR ED".

N (No impact on Not the UE in involved idle mode)

1~30

dB

14

14

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "ULAFSR EXQUAL HIGHTHR ED" >= "ULAFSR EXQUAL LOWTHR ED".

N (No impact on Not the UE in involved idle mode)

1~30

dB

16

16

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "ULAHSR EXQUAL HIGHTHR ED" >= "ULAHSR EXQUAL LOWTHR ED".

N (No impact on Not the UE in involved idle mode)

1~30

dB

16

16

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "ULAHSR EXQUAL HIGHTHR ED" >= "ULAHSR EXQUAL LOWTHR ED".

N (No impact on Not the UE in involved idle mode)

0.5~4, step:0.5

Cell

This parameter is valid only when "BETTER CELLHO EN" is set to YES and "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2. The following condition must be met: "ULBQST ATTIME" >= "ULBQLA STTIME".

N (No impact on Not the UE in involved idle mode)

0.5~4, step:0.5

Cell

This parameter is valid only when "BETTER CELLHO EN" is set to YES and "HOCTRL SWITCH" is set to Read & HOALGO Write RITHM2. The following condition must be met: "ULBQST ATTIME" >= "ULBQLA STTIME".

N (No impact on Not the UE in involved idle mode)

1~255

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~240

ms

180

In Abis over TDM transmission, the recommende d value is 180; in Abis Cell over IP transmission, the recommende d value is 200.

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64

None

15

15

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

10

10

Cell

This parameter is valid when "FRINGE HOEN" is Read & set to Write YES or "RXQCKF ALLHOE N" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~64

None

20

20

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~64

None

32

32

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~10

None

Cell

This parameter is valid only when Read & "PWRCT Write RLOPTIM IZEDEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~30

dB

16

16

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "ULFSRE XQUALHI GHTHRE D" >= "ULFSRE XQUALL OWTHRE D".

N (No impact on Not the UE in involved idle mode)

1~30

dB

16

16

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "ULFSRE XQUALHI GHTHRE D" >= "ULFSRE XQUALL OWTHRE D".

N (No impact on Not the UE in involved idle mode)

1~30

dB

18

18

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "ULHSRE XQUALHI GHTHRE D" >= "ULHSRE XQUALL OWTHRE D".

N (No impact on Not the UE in involved idle mode)

1~30

dB

18

18

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. The Read & following Write condition must be met: "ULHSRE XQUALHI GHTHRE D" >= "ULHSRE XQUALL OWTHRE D".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "ULTHF1" Write + "ULHYST F1" < "ULTHF2" + "ULHYST F2".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "ULTHF2" Write + "ULHYST F2" < "ULTHF3" + "ULHYST F3".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "ULTHH1 Write "+ "ULHYST H1" < "ULTHH2 "+ "ULHYST H2".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "ULTHH2 Write "+ "ULHYST H2" < "ULTHH3 "+ "ULHYST H3".

N (No impact on Not the UE in involved idle mode)

0~15

None

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "ULTHW Write B1" + "ULHYST WB1" < "ULTHW B2" + "ULHYST WB2".

N (No impact on Not the UE in involved idle mode)

0~15

None

Cell

The setting of this parameter must meet the following condition: Read & "ULTHW Write B1" + "ULHYST WB1" < "ULTHW B2" + "ULHYST WB2".

N (No impact on Not the UE in involved idle mode)

1~100

None

90

90

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI Read & C" is set Write to PWR2 and "UPPCEN " in "SET GCELLB ASICPAR A" is set to YES.

N (No impact on Not the UE in involved idle mode)

1~30

dB

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

1~30

dB

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

1~100

None

100

100

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~3

None

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI Read & C" is set Write to PWR2 and "UPPCEN " in "SET GCELLB ASICPAR A" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "ULQLO WTHRED " >= "ULQHIG HTHRED" .

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "ULQLO WTHRED " >= "ULQHIG HTHRED" .

N (No impact on Not the UE in involved idle mode)

TCH:480 ~9600, step:480; ms SDCCH:4 70~9400, step:470

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI Read & C" is set Write to PWR2 and "UPPCEN " in "SET GCELLB ASICPAR A" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~7

None

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~63

dB

Cell

This parameter is valid when "PWRCT RLSW" in Read & the "SET Write GCELLP WRBASI C" command is set to PWR2.

N (No impact on Not the UE in involved idle mode)

0~70

None

55

55

Cell

This parameter is valid only when "BQHOE N" in "SET GCELLH OBASIC" Read & is set to Write YES and "NODLM RHOEN" in "SET GCELLH OEMG" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~70

None

60

60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

55

55

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~10

None

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

TCH:0~9 120, step:480; ms SDCCH:0 ~8930, step:470

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

0~63

dB

18

18

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. Read & The Write following condition must be met: "ULREXL EVHIGHT HRED" >= "ULREXL EVLOWT HRED".

N (No impact on Not the UE in involved idle mode)

0~63

dB

18

18

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR3. Read & The Write following condition must be met: "ULREXL EVHIGHT HRED" >= "ULREXL EVLOWT HRED".

N (No impact on Not the UE in involved idle mode)

TCH:0~9 120, step:480; ms SDCCH:0 ~8930, step:470

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

0~10

None

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

TCH:0~9 120, step:480; ms SDCCH:0 ~8930, step:470

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

TCH:0~9 120, step:480; ms SDCCH:0 ~8930, step:470

Cell

This parameter is valid only when "PWRCT Read & RLSW" in Write "SET GCELLP WRBASI C" is set to PWR3.

N (No impact on Not the UE in involved idle mode)

0~100

None

Cell

This parameter is valid only when Read & "PWRCT Write RLOPTIM IZEDEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~100

None

75

75

Cell

This parameter is valid only when Read & "PWRCT Write RLOPTIM IZEDEN" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "ULSSHI GHTHRE D" >= "ULSSLO WTHRED ".

N (No impact on Not the UE in involved idle mode)

0~63

dB

18

18

Cell

This parameter is valid only when "PWRCT RLSW" in "SET GCELLP WRBASI C" is set to PWR2. Read & The Write following condition must be met: "ULSSHI GHTHRE D" >= "ULSSLO WTHRED ".

N (No impact on Not the UE in involved idle mode)

0~63

dB

15

15

Cell

The setting of this parameter must meet the following conditions : "ULTHF1" Read & < Write "ULTHF2" ; "ULTHF1" + "ULHYST F1" < "ULTHF2" + "ULHYST F2".

N (No impact on Not the UE in involved idle mode)

0~63

dB

19

19

Cell

The setting of this parameter must meet the following conditions : "ULTHF2" Read & < Write "ULTHF3" ; "ULTHF2" + "ULHYST F2" < "ULTHF3" + "ULHYST F3".

N (No impact on Not the UE in involved idle mode)

0~63

dB

28

28

Cell

The setting of this parameter must meet the following conditions : "ULTHF2" Read & < Write "ULTHF3" ; "ULTHF2" + "ULHYST F2" < "ULTHF3" + "ULHYST F3".

N (No impact on Not the UE in involved idle mode)

0~63

dB

23

23

Cell

The setting of this parameter must meet the following conditions : "ULTHH1 Read & "< Write "ULTHH2 "; "ULTHH1 "+ "ULHYST H1" < "ULTHH2 "+ "ULHYST H2".

N (No impact on Not the UE in involved idle mode)

0~63

dB

31

31

Cell

The setting of this parameter must meet the following conditions : "ULTHH2 Read & "< Write "ULTHH3 "; "ULTHH2 "+ "ULHYST H2" < "ULTHH3 "+ "ULHYST H3".

N (No impact on Not the UE in involved idle mode)

0~63

dB

63

63

Cell

The setting of this parameter must meet the following conditions : "ULTHH2 Read & "< Write "ULTHH3 "; "ULTHH2 "+ "ULHYST H2" < "ULTHH3 "+ "ULHYST H3".

N (No impact on Not the UE in involved idle mode)

0~63

dB

21

21

Cell

The setting of this parameter must meet the following conditions : "ULTHW Read & B1" < Write "ULTHW B2"; "ULTHW B1" + "ULHYST WB1" < "ULTHW B2" + "ULHYST WB2".

N (No impact on Not the UE in involved idle mode)

0~63

dB

25

25

Cell

The setting of this parameter must meet the following conditions : "ULTHW Read & B1" < Write "ULTHW B2"; "ULTHW B1" + "ULHYST WB1" < "ULTHW B2" + "ULHYST WB2".

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

1~64

None

32

32

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~255

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

GSM_PH ASE_1, GSM_PH ASE_2, None GSM_PH ASE_2Plu s

It is recommende d that the value of this GSM_PHAS parameter is BSC E_2 the same as that for "A Interface Tag".

Generally, the value of this parameter is equal to Read & "A Write Interface Tag" and "Abis Interface Tag".

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

E1/T1 port

None

Read & Write

Not involved

Not involved

1~6

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

40

40

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

40

40

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

40

40

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

60

60

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

60

60

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~3500

mA

60

60

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

BTS

None

Read & Write

BTS

0~2047

None

None

None

BTS

None

Read & Write

BTS

BYNAME, None BYID

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYNAME, None BYID

None

None

BTS

None

Read & Write

Not involved

Not involved

1~64 character None s

None

None

BTS

None

Read & Write

BTS

1~64 character None s

None

None

BTS

None

Read & Write

BTS

0~15

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CS1, CS2, None CS3, CS4

CS1

CS1

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, MCS9

None

MCS2

MCS2

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~70

None

20

20

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, UAS7, UAS8, UAS9, UAS10, UAS11

None

MCS6

MCS6

Cell

This parameter is valid Read & only when Write "EGPRS2 A" is set to YES.

N (No impact on Not the UE in involved idle mode)

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, None UAS7, UAS8, UAS9, UAS10, UAS11, UNFIXED

UNFIXED

UNFIXED

Cell

This parameter is valid Read & only when Write "EGPRS2 A" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~5000

ms

2000

2000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CS1, CS2, CS3, None CS4, UNFIXED

UNFIXED

UNFIXED

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

MCS1, MCS2, MCS3, MCS4, MCS5, None MCS6, MCS7, MCS8, MCS9, UNFIXED

UNFIXED

UNFIXED

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~70

None

40

40

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~63

dB

30

30

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

10~255

30

30

BTS

This parameter is valid Read & only when Write "ENABLE " is set to YES.

N (No impact on Not the UE in involved idle mode)

0~96

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~2047

None

None

None

When "ISFIRST CLASSE" Transmis in "ADD sion Read & RSCGRP resource Write " is set to group NO, this parameter is valid.

Not involved

Not involved

512~1535 None

None

None

None

None

Read & Write

Not involved

Not involved

1~16

Cell

The following condition must be met: Read & "UPRXLE Write VSTATIC TIME" >= "UPRXLE VLASTTI ME".

N (No impact on Not the UE in involved idle mode)

0.1~1, step:0.1

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~16

Cell

The following condition must be met: Read & "UPRXLE Write VSTATIC TIME" >= "UPRXLE VLASTTI ME".

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~300

ms

120

120

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

10

10

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~64

per cent

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

FORBID, None PERMIT

PERMIT

PERMIT

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

BYTMSI, BYIMSI, BYMSISD None N, BYIMEI

None

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOTSUP PORT, None SUPPOR T

NOTSUPPO NOTSUPPO BSC RT RT

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~32 character None s

None

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HOUR 0~23 MINUTE 0~59

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

HOUR 0~23 MINUTE 0~59

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

-99~99

degree Celsius

50

50

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~8

None

Cell

This parameter is valid only when "IUOTP" Read & in "ADD Write GCELL" is set to Concentri c_cell.

N (No impact on Not the UE in involved idle mode)

0~255

10

10

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

0~63

dB

35

35

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

1~255

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

1~63

dB

Cell

This parameter is valid only when Read & "IUOTP" Write in "ADD GCELL" is set to EDB_cell.

N (No impact on Not the UE in involved idle mode)

FDD, TDD

None

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

2 character None s

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~190, 255

None

255

255

Cell

"VGCSRS RVNUM"" Read & <= Write "VGCSM AXNUM".

N (No impact on Not the UE in involved idle mode)

No_Priorit y, Public_Ne twork_Fir None st, VGCS_Fir st

No_Priority

No_Priority

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~190

None

Cell

"VGCSRS RVNUM"" + PDTCH Number Read & <= Cell Write total service Channels

N (No impact on Not the UE in involved idle mode)

50~95

per cent

95

95

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NONE, LEVEL4, LEVEL3, LEVEL2, None LEVEL1, LEVEL0, LEVELB, LEVELA

LEVEL0

LEVEL0

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

50~95

per cent

90

90

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

DISABLE, None ENABLE

DISABLE

DISABLE

IP path

None

Read & Write

IP path

DISABLE, None ENABLE

None

None

BSC6900 None

Read & Write

Not involved

Not involved

DISABLE, None ENABLE

DISABLE

DISABLE

SCTP link None

Read & Write

SCTP link

DISABLE, None ENABLE

DISABLE

DISABLE

SCTP link None

Read & Write

SCTP link

2~4094

None

None

None

BSC6900 None

Read & Write

BSC6900

2~4094

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

2~4094

None

BTS

This parameter is valid only when Read & "VLANS Write WITCH" is set to YES.

N (No impact on Not the UE in involved idle mode)

2~4094

None

None

None

Ethernet port

None

Read & Write

Not involved

Not involved

2~4094

None

None

None

BSC6900 None

Read & Write

BSC6900

2~4094

None

None

None

BSC6900 None

Read & Write

BSC6900

0~7

None

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~7

None

BTS

This parameter is valid only when Read & "VLANS Write WITCH" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Full_rate_ Ver1, Full_rate_ Ver2, Full_rate_ Ver3, Half_rate None _Ver1, Half_rate _Ver2, Half_rate _Ver3, Full_rate_ Ver5

FULL_RATE _VER11&FULL_RA TE_VER21&FULL_RA TE_VER30&HALF_RA TE_VER11&HALF_RA TE_VER20&HALF_RA TE_VER30&FULL_RA TE_VER5-0

FULL_RATE _VER11&FULL_RA TE_VER21&FULL_RA TE_VER30&HALF_RA Cell TE_VER11&HALF_RA TE_VER20&HALF_RA TE_VER30&FULL_RA TE_VER5-0

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

OPEN

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character V s

28

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character V s

20

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

OPEN

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character V s

57

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~9 character V s

42

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

YES

YES

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~12

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~30

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

14, 15, 16, 18, 20, 22, 24, 26, 28, 30, 33, 36, 88

None

20

20

BTS

This parameter must be at least 0.2 Read & smaller Write than "Serious VSW Alarm TH".

N (No impact on Not the UE in involved idle mode)

18, 20, 22, 24, 26, 28, 30, 32, 35, 38, 41, 45, 88

None

30

30

BTS

This parameter must be at least 0.2 greater Read & than Write "Standing Wave Radio Alarm Threshold ".

N (No impact on Not the UE in involved idle mode)

0~12

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~999

None

None

None

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

4000~330 ms 00

27000

27000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

3000~340 ms 00

34000

34000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

3000~340 ms 00

26000

26000

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

280

280

BSC

Timer of MS Location Response from Read & MS<Time Write r of MS Location Response from SMLC

N (No impact on Not the UE in involved idle mode)

1~30

15

15

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~60

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

0~1000

300

300

BSC

Timer of MS Location Response from Read & MS<Time Write r of MS Location Response from SMLC

N (No impact on Not the UE in involved idle mode)

INACTIV E, ACTIVE

None

INACTIVE

INACTIVE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

CLOSE, OPEN

None

OPEN

None

None

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NOLIMIT, None LIMIT

NOLIMIT

NOLIMIT

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

East_Lon gitude, None West_Lon gitude

None

None

Cell

None

Read & Write

N (No impact on Not the UE in involved idle mode)

INACTIV E, ACTIVE

None

INACTIVE

INACTIVE

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

NO, YES None

None

None

None

None

Read & Write

Not involved

Not involved

DENY, ALLOW

None

DENY

None

BSC

None

Read & Write

N (No impact on Not the UE in involved idle mode)

SUN, MON, TUE, None WED, THU, FRI, SAT

None

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

M3UA_A SP, None M3UA_IP SP

M3UA_ASP

M3UA_ASP

SCCP

None

Read & Write

Not involved

Not involved

0~24

22

22

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

5~1275, step:5

min

12

12

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

0~24

TRX

This parameter is valid only when Read & "WLNKAL Write MFLAG" is set to YES.

N (No impact on Not the UE in involved idle mode)

NO, YES None

NO

NO

TRX

None

Read & Write

N (No impact on Not the UE in involved idle mode)

Active, Standby

None

Active

Active

BSC6900 None

Read & Write

Not involved

Not involved

GSM_AN D_UMTS, None UMTS, GSM

GSM

GSM

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

GO

None

None

None

None

None

Read & Write

Not involved

Not involved

E1_UNBA , E1_BA, None T1, E1

None

None

E1/T1 port

None

Read & Write

BSC6900

E1, T1

None

E1

E1

BTS

None

Read & Write

N (No impact on Not the UE in involved idle mode)

1~127

None

None

16

ATERCO None NSL

Read & Write

N (No impact on Not the UE in involved idle mode)

30~300

90

90

BTS

This parameter is valid Read & only when Write "OMLBKU P" is set to YES.

N (No impact on Not the UE in involved idle mode)

60~300

90

90

BTS

This parameter must meet the following requireme nts: "FallBack Read & Start Write Time" > "Ring I Wait Time Before Switch" + "Ring I Try Rotating Duration None Read & Write

N (No impact on Not the UE in involved idle mode)

30~60000 s GMT1200(GM T-12:00), GMT1100(GM T-11:00), GMT1000(GM T-10:00), GMT0930(GM T-09:30), GMT0900(GM T-09:00), GMT0800(GM None T-08:00), GMT0700(GM T-07:00), GMT0600(GM T-06:00), GMT0500(GM T-05:00), GMT0430(GM T-04:30), GMT0400(GM T-04:00), GMT-

None

600

MSP protect group

Not involved

Not involved

GMT+0800

None

BSC6900 None

Read & Write

N (No impact on Not the UE in involved idle mode)

Interrupti on Caution Duration( Min)

Not involved

None

Impact Validatio on Radio n of Network Modificat Performa ion nce The smaller The the value parameter of this modificati parameter on has no is, the impact on more MSs the select a equipmen neighbori t. ng cell in directed retry.

Introduce d in Attribute Version

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The smaller the value of this parameter BSC6900 is, the V900R01 Radio more MSs 1 select a neighbori ng cell in directed retry.

Not involved

The value of this parameter must be greater than five times the maximum value of the following parameter : "Filter Length for SDCCH Level", "Filter Length for SDCCH Qual", "Filter Length for TCH Level", "Filter Length for TCH Qual", "Filter Length for TA", "TA filter length for SDCCH

The parameter modificati on has no impact on the equipmen t.

The setting of this parameter BSC6900 affects V900R01 Radio the 1 access delay of parts of MSs.

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

This parameter should be set to ON when the transmissi on delays of different 64 kbit/s timeslots are different over the Abis interface in TDM transmissi on mode. Different transmissi on delays usually occur in the DXX network mode or when the transmissi on paths of multiple E1 links are different

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

If this parameter is set too high, a normal voice may be considere d abnormal. If this parameter is set too low, an abnormal voice may not be considere d.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When the access control function is enabled, some BSC6900 MSs are V900R01 Radio caused to 1 be inaccessi ble to the network for some time.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The throughpu t is affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter is valid only when "BSSPAG INGCOO RDINATI ON" in "SET GCELLP SBASE" is set to YES.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

ACS is usually set to 0 because system informatio n 7 and 8 message s are seldom used in common cells. ACS should be set to 1 if system informatio n 7 and 8 message s are used in a cell and C2 is used for cell reselectio n.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The number of the chosen data rates must be from one to four. If this parameter involves only one full rate coding rate, the value of "AMR Starting Mode[F]" can be 0 only; all the adjustable threshold s and hysteresis of AMR coding rate make no sense. If this parameter involves two

The parameter modificati on has no impact on the equipmen t.

The ACS may affect the MOS. Modifying the default coding rates will affect speech quality when TrFO or TFO is in use.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The number of the chosen data rates must be from one to four. If this parameter involves only one half rate coding rate, the value of "AMR Starting Mode[H]" can be 0 only; all the adjustable threshold s and hysteresis of AMR coding rate make no sense. If this parameter involves two

The parameter modificati on has no impact on the equipmen t.

The ACS may affect the MOS. Modifying the default coding rates will affect speech quality when TrFO or TFO is in use.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The number of the chosen data rates must be from one to three. If this parameter involves only one coding rate, the value of "AMR Starting Mode[WB ]" can be 0 only; all the adjustable threshold s and hysteresis of AMR coding rate make no sense. If this parameter involves two coding

The parameter modificati on has no impact on the equipmen t.

The ACS may affect the MOS. Modifying the default coding rates will affect speech quality when TrFO or TFO is in use.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The switching from an intra-cell handover procedure to an assignme nt procedure shortens the duration of the intra-cell handover.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None.

The parameter modificati on has no None. impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

The services are disrupted None until this parameter is set to Unlock.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Services will be disrupted until the value of this None parameter is changed to "Unlock".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Services will be disrupted until the value of this None parameter is changed to "Unlock".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The radio link should be reestablis hed after None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablis hed after None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablishe None d after the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablis hed after None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablishe None d after the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablishe d after the parameter modificati on.

If this parameter is set to OPEN, the acoustic echo can be cancelled to improve the speech

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablis hed after None the parameter modificati on.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The radio link should be reestablis hed after None the parameter modificati on.

BSC6900 Equipmen V900R01 t 1

Not involved

With a good antiinterferen ce capability, AMR codes can support a lower carrier-tointerferen ce ratio than nonAMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "Radio Link

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

With a good antiinterferen ce capability, AMR codes can support a lower carrier-tointerferen ce ratio than nonAMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "SACCH The parameter cannot be modified.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

Versions earlier Equipmen than t BSC6900 V900R01 BSC6900 Equipmen V900R01 t 1

Not involved

With a good antiinterferen ce capability, AMR codes can support a lower carrier-tointerferen ce ratio than nonAMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "Radio Link

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

With a good antiinterferen ce capability, AMR codes can support a lower carrier-tointerferen ce ratio than nonAMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "SACCH

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

If this parameter is set to a greater value, TRX mutual aid may not be triggered promptly in the case of BCCH TRX failure after a cell has just been initialized. If this parameter is set to smaller value, mutual aid may be decided mistakenl y.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The radio link should be reestablishe None d after the parameter modificati on. radio The link should be reestablis hed after None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablis hed after None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablis hed after None the parameter modificati on. radio The link should be reestablis hed after None the parameter modificati on. The radio link should be reestablis hed after None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablis hed after the parameter modificati on.

If this parameter is set to OPEN, the voltage level can be adjusted automatic ally to improve the speech

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid only when "SUPPOR TEDA" is set to SUPPOR T.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. If this parameter is set to a smaller value, the dynamic power adjustme The nt range parameter for the modificati BTS is on has no decrease impact on d. This the may equipmen cause t. power waste and increase network interferen ce when the downlink

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to YES and the value of the downlink threshold is not reasonabl e, the BSC6900 algorithm V900R01 Radio can be 1 used to dynamical ly adjust the AMR downlink rate to increase the downlink speech MOS.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, downlink power control may not be performe d when the voice quality is good, thus causing the power waste and increasing the interferen ce. If this parameter is set to a greater value, downlink power control may be performe d when the voice

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, uplink power control may not be performe d when the voice quality is bad, thus affecting the voice quality. If this parameter is set to a smaller value, uplink power control may be performe d when the voice quality is good, thus causing

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, downlink power control may not be performe d when the downlink level is high, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, downlink power control may be performe d when the

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, uplink power control may be performe d when the downlink level is high, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, power control may not be performe d when the downlink

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this switch is turned on, AMR FR calls can be switched into AMR HR calls to relieve the network congestio n, but the voice quality is decrease d; if this switch is turned off, AMR FR calls cannot be switched into AMR HR calls, that is, network congestio n cannot be relieved through the

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover margin is increased in a short period and many MSs are handed over from TCHF to TCHH, thus affecting the voice quality. If this parameter is set to a smaller value, the handover margin is enlarged slowly and it takes a long time to initiate a TCHF-

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, only MSs in the center of the cell can meet the handover condition. Thus, the network congestio n cannot be relieved in time. If this parameter is set to a smaller value, MSs at the edge of the cell can also meet the handover condition, thus affecting

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover margin is increased in a short period and many MSs are handed over from TCHF to TCHH, thus affecting the voice quality. If this parameter is set to a smaller value, the handover margin is enlarged slowly and it takes a long time to initiate a TCHF-

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, MSs at the edge of the cell can also meet the handover condition, thus affecting the voice quality. If this parameter is set to a smaller value, only MSs in the center of the cell can meet the handover condition. Thus, the network congestio n cannot be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, MSs with poor quality can also meet the handover condition, thus affecting the voice quality. If this parameter is set to a smaller value, little MSs can meet the handover condition. Thus, the network congestio n cannot be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the calls cannot be handed over to TCHH in a short period when the traffic volume is increased greatly. Thus, the network congestio n cannot be relieved in time. If this parameter is set to a smaller value, calls are handed over to TCHH unnecess

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, only MSs in the center of the cell use the TCHH, thus leading to timeslot waste and the network congestio n cannot be relieved in time. If this parameter is set to a smaller value, MSs at the edge of the cell and with poor quality also

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, MSs at the edge of the cell and with poor quality also cannot be handed over to the TCHF, thus affecting the voice quality. If this parameter is set to a smaller value, only MSs in the center of the cell use the TCHH, thus leading to

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, handover cannot be triggered even when the quality is poor, thus affecting the voice quality; if this parameter is set to a smaller value, handover is triggered even when the quality is good, thus the network congestio n cannot be relieved in

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, calls are handed over to TCHH unnecess arily, thus causing MOS loss of the customer; if this parameter is set to a greater value, TCHFTCHH handover is performe d only when the traffic volume is high, and thus network congestio If this parameter is set to a smaller value, call drops may occur due to delayed power control; if this parameter is set to a greater value, power waste may occur and network interferen

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, fast power control cannot be realized. If this parameter is set to a greater value, the power control may be performe d excessive ly, thus leading to call drops.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, fast power control cannot be realized. If this parameter is set to a greater value, the power control may be performe d excessive ly, thus leading to call drops.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, fast power control cannot be realized. If this parameter is set to a greater value, the power control may be performe d excessive ly, thus leading to call drops.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, call drops may occur due to delayed power control; if this parameter is set to a greater value, power waste may occur and network interferen

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, power control may not be performe d in time. If this parameter is set to a smaller value, power control may be performe d frequently , thus increasing the signaling

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the algorithm cannot realize fast power control. If this parameter is set to a greater value, call drops may

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, cell congestio n may not be relieved. If this parameter is set to a smaller value, TCHFs may be assigned unnecess arily, thus affecting the voice quality.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to YES and the value of the uplink threshold is not reasonabl e, the BSC6900 algorithm V900R01 Radio can be 1 used to dynamical ly adjust the AMR uplink rate to increase the uplink speech MOS.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, downlink power control may not be performe d when the voice quality is good, thus causing the power waste and increasing the interferen ce. If this parameter is set to a greater value, downlink power control may be performe d when the voice

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, uplink power control may not be performe d when the voice quality is bad, thus affecting the voice quality. If this parameter is set to a smaller value, uplink power control may be performe d when the voice quality is good, thus causing

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, power control may not be performe d when the uplink level is high, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, downlink power control may be performe d when the uplink power is low, in

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, uplink power control may be performe d when the uplink level is high, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, power control may not be performe d when the uplink power is low, in

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablishe None d after the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablishe d after the parameter modificati on.

If this parameter is set to OPEN, the noise can be compens ated automatic ally to improve the speech quality.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The radio link should be reestablishe None d after the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The adjacent node ID must be configure d.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. radio The link should be reestablis hed after None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The radio link should be reestablishe None d after the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The radio link should be reestablis hed after None the parameter modificati on. If this parameter The radio is set to link OPEN, should be the noise reestablis can be hed after depresse the d parameter automatic modificati ally to on. improve the speech

Versions earlier than Equipmen BSC6900 t V900R01 1

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter is valid only when "AqmSwit ch" is set to OPEN.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid only when "AqmSwit ch" is set to OPEN.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid only when "AqmSwit ch" is set to OPEN.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid only when "AqmSwit ch" is set to OPEN.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid only when "AqmSwit ch" is set to OPEN.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid only when "AqmSwit ch" is set to OPEN.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

This parameter is valid only when "AqmSwit ch" is set to OPEN.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Interrupt the service until the correct gateway is set or the port swapping or the changing of IP route is finished.

To modify this parameter , run "STP GATEWA YCHK" first and then "STR GATEWA YCHK".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

To modify this parameter , run "STP GATEWA YCHK" first and then "STR GATEWA YCHK".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Before enabling this function, ensure that the parameter "Directed Retry" of the cell is set to YES. To obtain MRs on the SDCCH as many as possible, set the parameter s "Waiting for MR on SDCCH Switch" and "IBCA Allowed" to YES.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to YES, the voice quality is enhanced and the handover times is reduced, but the call access delay is prolonged BSC6900 . The call V900R01 Radio access 1 delay is affected by both the setting of "Maximu m Assigning Duration" and the duration for waiting MRs on the SDCCH. The

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a higher value, channel resources may be wasted and congestio n occurs; if this parameter is set to a lower value, the assignme nt success rate may decrease.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the overlaid subcell range in the algorithm is smaller than the actual range, thus leading to the unbalanc e between the traffic volume on the overlaid subcell and that on the underlaid subcell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, TCHFs are preferenti ally selected even when congestio n occur on the Ater interface, thus decreasin g the system capacity. If this parameter is set to a lower value, TCHHs are selected when no congestio n occur on the

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Less than 10 None minutes

The BSC should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The ATT must be set to the same value for different cells in a same location area. If not, some MSs after power-on may not act as a called party until they have waited for the period specified by "T3212".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

BSC6900 V900R01 Transport 1

The parameter modificati Not on has no None None involved impact on the equipmen Negotiatio t. n can succeed The Interrupt only when parameter the the modificati service configurat on has no until None ion is impact on negotiate consistent the successfu on the equipmen lly again. local and t. peer ends. Negotiatio n can succeed Interrupt only when the the service configurat until ion is negotiate consistent successfu on the lly again. local and peer ends. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Versions earlier than Transport BSC6900 V900R01 1

Versions earlier than Transport BSC6900 V900R01 1

Negotiatio n can succeed only when the Less than configurat 5 minutes ion is consistent on the local and peer ends.

The transport path should be reNone establishe d after the parameter modificati on.

BSC6900 V900R01 Transport 1

Negotiatio n can succeed Interrupt only when the the service configurat until ion is negotiate consistent successfu on the lly again. local and peer ends.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Negotiatio n can succeed Interrupt only when the the service configurat until ion is negotiate consistent successfu on the lly again. local and peer ends.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Negotiatio n can succeed only when the Less than configurat 5 minutes ion is consistent on the local and peer ends.

The transport path should be reNone establishe d after the parameter modificati on.

BSC6900 V900R01 Transport 1

Negotiatio n can succeed Interrupt only when the the service configurat until ion is negotiate consistent successfu on the lly again. local and peer ends. Negotiatio n can succeed Interrupt only when the the service configurat until ion is negotiate consistent successfu on the lly again. local and peer ends.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Negotiatio n can succeed only when the Less than configurat 5 minutes ion is consistent on the local and peer ends.

The transport path should be reNone establishe d after the parameter modificati on.

BSC6900 V900R01 Transport 1

Negotiatio n can succeed Interrupt only when the the service configurat until ion is negotiate consistent successfu on the lly again. local and peer ends. Negotiatio n can succeed Interrupt only when the the service configurat until ion is negotiate consistent successfu on the lly again. local and peer ends. Negotiatio n can succeed only when the Less than configurat 5 minutes ion is consistent on the local and peer ends.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The transport path should be reNone establishe d after the parameter modificati on.

BSC6900 V900R01 Transport 1

The port can be set to the DOWN or UP state when this parameter is Interrupt modified. the If the service negotiatio until n modes negotiate on the successfu local and lly again. peer end are not consistent , the service can be interrupte d.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If this parameter is set to YES, the BSC load is increased early in every morning. The auto negotiatio n mode of FE port on the IPbased interface board should be consistent with that of the port on the peer end. Otherwise , this may cause the packet loss and link disconnec tion.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

If the mode is not consistent , will interrupt service until it is consistent

If the mode is not consistent , will interrupt service until it is consistent

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Each backplane board 8K clock has only one clock source. You are not allowed to turn on the same backplane board 8K clock switch for multiple interface boards.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Each backplane board 8K clock has only one clock source. You are not allowed to turn on the same backplane board 8K clock switch for multiple interface boards.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

To modify this parameter , run "STP GATEWA YCHK" first and then "STR GATEWA YCHK". To modify this parameter , run "STP GATEWA YCHK" first and then "STR GATEWA YCHK".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The services are interrupte d until the SCTP link is working normally.

The parameter modificati on should be negotiate d with the peer end, and the BSC6900 should be reset after the modificati on. It is recomme nded that this parameter should not be modified when the system is running.

The BSC6900 should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Less than None 5 minutes

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Less than None 5 minutes

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time, thus the voice quality is decrease d and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a smaller value, handover s cannot be performe d in time. Thus the voice quality is decrease d and call drops

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

Not involved

To disable the alarm blink filter function, set this parameter to "0". To enable the alarm blink filter function, set this parameter to a value greater than 0 and turn on the alarm blink filter switch. See "SET ALMBLKS W" for setting the alarm blink filter To enable the alarm blink filter function, set "Alarm switch of blinking filter" and "Switch of stat blinking alarm" to "ENABLE ".

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If the value of this parameter is too small, the SCUs of the TC subrack may remain congeste d. If the value is too large, the call failure rate may retain a higher value for a longer

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe

Versions earlier than Radio BSC6900 V900R01 1

Not involved

When the M900/M1 800 BSC is upgraded to BSC6000, this parameter needs to be set to 69. If this parameter is not set to 69 in this case, the handover algorithm supported by this parameter is invalid.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a smaller value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

As defined in the protocol, the value of this parameter cannot be 0 in the following cases: The BSC needs to send system message s over the extended BCHs. CBCHs are configure d. When the GSMR is enabled, NCHs are configure

The parameter modificati on has no impact on the equipmen t.

The setting of this parameter may affect the MS paging response and performa nce of the system. A greater value may decrease the number of paging blocks, paging capacity, and paging success rate.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If "MR.Prep rocessing " is set to BTS_Pre processin g and this parameter is set to NO, the uplinkdownlink balance associate d traffic statistics is improper. In addition, the handover algorithm s that require power compens ation are improper, such as PBGT handover, load handover,

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

A paging block (four continuou s CCCH timeslots) can bear two IMSI paging message s, four TMSI paging message s, or two AGCH immediat e assignme nt message. If the signaling downlink is faulty when an MS is idle, the rule of downlink failure is based on the signaling downlink

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

If this parameter is set to a greater value, the number of paging subchann els in a cell increases and the number of MSs on each paging subchann el decrease s. This can prolong the average service life of MS batteries but increase the delay of paging message s and degrade

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is valid on a per cell basis and is valid only when "ACOOP ERATPA GINGSWI TCH" in the "SET BSCPSS OFTPAR A" command is set to YES.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If certain link is occupied, conversio n from E1 to T1 or from T1 to E1 cannot be performe

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. Not involved None

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

Not involved

Not involved

Not involved

The parameter cannot be modified. The parameter cannot be modified. The parameter cannot be modified.

Not involved

None

Not involved

None

Not involved

None

Not involved

The parameter Not cannot be involved modified.

The parameter modificati on has no None impact on the equipmen t. None

Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01

Transport

Transport

Transport

Transport

Transport

Transport

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If BTS Bar Code is incorrect, the OML between the BTS and the BSC cannot be establishe d. In this case, no alarm or status is displayed. When the BBU or BTS3900 E module of a BTS is replaced, you need to set a new BTS bar code for the BTS on

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on. The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

Not involved

The parameter This modificati parameter on has no None cannot impact on contain #. the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01

Not involved

The parameter Not cannot be involved modified.

Not involved

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

BSC6900 Equipmen V900R01 t 1

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

This parameter can be set to BTS_Pre processin g only when the BTS supports the configure d power control algorithm.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to BTS_Pre processin g, signaling on the Abis interface and BSC load are decrease d, thus enhancin g the response speed and the network performa nce.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

This parameter is required only by BTSs in IP transmissi on mode.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the range of BTS dynamic power adjustme nt is decrease d, and thus network interferen ce is difficult to be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

For a doubletransceive r BTS or an NGBTS, the initial value is ON. For a BTS of any other type, the initial value is OFF and unconfigu

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Call reestablis hment can decrease the call drop rate but waste channel resources .

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not Involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified.

None

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01

Not involved

If the value of "Cell Bar Access" is YES and the value of "Cell Bar Qualify" is NO, new call access is prohibited but handover access is allowed.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If the value of "Cell Bar Access" is YES and the value of "Cell Bar Qualify" is NO, new call access is prohibited but handover access is allowed.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the status of RF resources is reported too frequently , thus burdening the BSC6900. If this parameter is set to a greater value, the status of RF resources cannot be updated in time; therefore, the BSC6900 cannot handle the interferen

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to smaller value, the signaling flow over the Abis interface increases, thus burdening the BSC6900. If this parameter is set to a greater value, the BSC6900 cannot handle the exception s on the BTS in time, thus causing network congestio n.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. None

Not involved

The parameter Not cannot be involved modified.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter This modificati parameter on has no applies to None impact on only the the EDGE trx. equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. If the MSC supports processin g assignme nt complete message s containing cell lists, set this parameter to YES; otherwise, set this parameter to NO.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, dynamic adjustme nt may not be triggered when there are insufficien t SDCCHs in the cell, this affects the access success rate. If this parameter is set to a greater value, traffic volume on the TCH is decrease d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This feature only applies to the areas covered by both the GSM network and the UMTS network. The UMTS network is preferenti BSC6900 ally used V900R01 Radio to perform 1 the data services, and the GSM network is preferenti ally used to perform the speech services. When a user is handed over to the GSM

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

If this parameter is set too small, the congestio n control duration is too long, and thus the transmissi on capability of signaling links cannot be fully used. If the difference between the values of "CSTART THD" and "CENDTH D" is small, the signaling link is unstable and congestio n control

Versions earlier than Equipmen BSC6900 t V900R01 1

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The congestio n start threshold must be greater than the congestio n end threshold.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The congestio n start threshold must be greater than the congestio n end threshold.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The congestio n start threshold must be greater than the congestio n end threshold.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The congestio n start threshold must be greater than the congestio n end threshold.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The congestio n start threshold must be greater than the congestio n end threshold.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The setting of this parameter depends on the actual physical BSC6900 location of V900R01 Radio the chain 1 neighbori ng cell. Otherwise , fast PBGT handover may fail.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

This function can be activated only when the "Switch for Abis Timeslot Detection" is "ON".

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The purpose of setting this parameter is to avoid call connectio n failure when an MS supportin g the full rate channel only requests a half rate channel or an MS supportin g the half rate channel only requests a full rate channel. In this way, the BSC can easily interconn ect with

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

When the network status is poor, the check count should not be too small. Otherwise , the path state is affected.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A. This parameter is supported only by the BTS3012 A and BTS3006 A. The checksum mode need the negotiatio n with the peer. According to the RFC4960, the value should be set to CRC32. The checksum mode need the negotiatio n with the peer. According to the RFC4960, the value should be set to CRC32.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Versions earlier than Equipmen BSC6900 t V900R01 1

The services are interrupte d until the SCTP link is working normally.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The services are interrupte d until the SCTP link is working normally.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The services are interrupte None d until the SCTP link is working normally.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. If the MSC supports processin g assignme nt complete message s containing the Chosen Channel, set this parameter to YES;

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. If the MSC supports processin g handover performe d message s containing the Chosen Channel, set this parameter to YES; The setting of this parameter needs negotiatio n with the opposite network element MSC. If the MSC supports processin g HO REQ ACK message s containing the Chosen Channel, set this parameter to YES; otherwise, set this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. In this way, the MSC can process encryptio n complete message The setting of this parameter needs negotiatio n with the opposite network element MSC. In this way, the MSC can process handover performe d message

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. In this way, the MSC can process assignme nt complete message s correctly. An assignme nt complete message contains the Chosen Encryptio n Algorithm only when the

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. SENDING : The HO REQ ACK message contains the Chosen Encryptio n Algorithm. NOSENDI NG: The HO REQ ACK message does not contain the Chosen Encryptio n Algorithm. SYSTEM

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The smaller the value of this parameter is, the more sensitivel y the BSC controls the arrival rate of channel request message s, and vice versa.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 1 minute

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The CI can be input in hexadeci mal format. The hexadeci mal format is H'****, for example, H'1214.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

1. The block of A interface must be configure d. 2. If A over IP is configure d, the configurat ion does not support the operation.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. In this way, the MSC can process assignme nt complete message

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. In this way, the MSC can process HO FAIL message s The setting of this parameter needs negotiatio n with the opposite network element MSC. In this way, the MSC can process assignme nt failure message s correctly. NOSENDI NG: The assignme nt failure message does not contain the Circuit Pool List. SENDING PRO: If the cause value of assignme

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. In this way, the MSC can process HO FAIL message s The setting of this parameter needs negotiatio n with the opposite network element MSC. If the MSC does not support process assignme nt complete message s containing the Circuit Pool, the value YES of

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. If the MSC does not support process assignme nt complete message s containing the Circuit Pool, the value YES of

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on. The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

If you want to modify the value of "Clock board Less than type" from 10 "GCGa" minutes to "GCUa", the board must not be configure

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The board should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier Equipmen than t BSC6900 V900R01

Not involved

The parameter Not cannot be involved modified.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The value of this Not parameter involved cannot be changed.

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

1. If you set "Upper count threshold of raised fault" and "Lower count threshold of raised fault" to "0", the accumulat ed number of blink times for the alarm is counted but not reported. 2. If "Upper count threshold of raised fault" is not "0", the value of "Lower count threshold of raised

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

1. If you set "Upper count threshold of raised fault" and "Lower count threshold of raised fault" to "0", the accumulat ed number of blink times for the alarm is counted but not reported. 2. If "Lower count threshold of raised fault" is not 0, the value of "Upper count threshold of raised

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. This parameter can be used to limit the user access type to control the network load; however, some users may be adversely affected. Therefore , it is recomme nded that this parameter be disabled.

BSC6900 Equipmen V900R01 t 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier Equipmen than t BSC6900 V900R01

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

Not involved

None

The BTS should be reset to validate None the parameter modificati on. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, handover s may be performe d frequently ; if this parameter is set to a greater value, handover s may not be performe d in time and call drops may occur.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, handover s may be performe d frequently ; if this parameter is set to a greater value, handover s may not be performe d in time and call

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

This parameter cannot be set to YES for the TRX that carries the main BCCH.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The MS cannot respond to the paging during the location update, thus decreasin g the call completio n rate in the system. If this parameter is set to a smaller value, pingpong location update may occur, thus increasing the signaling load on the SDCCH. If this parameter

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is not supported by the BTS3001 C and BTS3001 CP.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The settings of RXLEVACCESSMIN and CRO should guarantee that cells with same priority have the same cell reselect offset.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter is related to practical networkin g.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

Not involved

The modificati on of the parameter affects the adjacent node that is configure d with the factor table. After the successfu l modificati on, the parameter takes effect in the following two cases: 1. New access subscribe r. 2. Bandwidt h modificati The modificati on of the parameter affects the adjacent node configure d with the TRMMAP. After the successfu l modificati on, it is valid in the case of the new access of a subscribe r and the bandwidth modificati

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Not involved

The modificati on of the parameter affects the adjacent node configure d with the TRMMAP. After the successfu l modificati on, it is valid in the case of the new access of a subscribe r and the bandwidth modificati The modificati on of the parameter affects the adjacent node that is configure d with the factor table. After the successfu l modificati on, the parameter takes effect in the following two cases: 1. New access subscribe r. 2. Bandwidt h modificati

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The larger the value of this parameter , the higher the proportion of discarded message s during congestio n. Therefore , the priority value of a more important service must be less than that of a less important

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

If the value of this parameter is too high, the congestio n control is delayed, which leads to deteriorat ed performa nce on the signaling link and certain message s may be lost. If the difference between the values of "CSTART THD" and "CENDTH D" is small, the signaling

Versions earlier than Equipmen BSC6900 t V900R01 1

BSC6900 Equipmen V900R01 t 1

Not involved

The modificati on of the parameter affects the adjacent node that is configure d with the factor table. After the successfu l modificati on, the parameter takes effect in the following two cases: 1. New access subscribe r. 2. Bandwidt h modificati

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

Not involved

The modificati on of the parameter affects the adjacent node configure d with the TRMMAP. After the successfu l modificati on, it is valid in the case of the new access of a subscribe r and the bandwidth modificati The modificati on of the parameter affects the adjacent node configure d with the TRMMAP. After the successfu l modificati on, it is valid in the case of the new access of a subscribe r and the bandwidth modificati

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Not involved

The modificati on of the parameter affects the adjacent node that is configure d with the factor table. After the successfu l modificati on, the parameter takes effect in the following two cases: 1. New access subscribe r. 2. Bandwidt h modificati The larger the value of this parameter , the higher the proportion of discarded message s during congestio n. Therefore , the priority value of a more important service must be less than that of a less important

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

If this parameter of an activated Less than BTS is 5 minutes modified, the entire BTS chain is reset. If this parameter of an activated Less than BTS is 5 minutes modified, the entire BTS chain is reset.

The BTS should be reset to validate None the parameter modificati on. The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The setting of this parameter needs negotiatio n with the opposite network element MSC. In this way, the MSC can process HO RQD message s

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. None

BSC6900 Equipmen V900R01 t 1

None

BSC6900 Equipmen V900R01 t 1

Less than 10 None minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not Involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this timer is set to a greater value, channel resources may be wasted, thus causing congestio n.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Not involved

Not involved

When running this command , the source IP address and the destinatio n IP address cannot be the local IP address and the peer IP address configure The parameter cannot be modified. The parameter cannot be modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t. The BTS should be reset to validate None the parameter modificati on.

BSC6900 Equipmen V900R01 t 1

This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Less than None 1 minute

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None.

The parameter modificati on has no impact on the equipmen t.

If this timer is set to a greater value, channel resources may be wasted, thus causing congestio n.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. Not involved

BSC6900 V900R01 Transport 1

Not involved

None

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified.

Not involved

None

Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 1

Equipmen t

Equipmen t

Transport

Not involved

The parameter Not cannot be involved modified.

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

BSC6900 V900R01 Transport 1

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter takes effect only when the SDCCH exists on the TRXs on different frequency bands.

The parameter modificati on has no impact on the equipmen t.

If this function is enabled, number of signaling channel handover s is increased and the access speed is decrease d, but the congestio n on the BCCHcompatibl e SDCCH can be relieved and the access success rate is enhanced .

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The setting of this parameter needs negotiatio n with the MSC of the opposite network element. If the MSC supports processin g assignme nt failure message s containing the cause value of direct retry, set this parameter to YES;

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If the value of this parameter is YES, the intraBSC handover s (including intra-cell handover s) in which the cell is the source or destinatio n cell are processe d as asynchro nous handover s.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If this parameter is set to 15, this protection is disabled.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter applies to only the doubletransceive r BTS and the correspon ding distribute d BTS.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

This parameter applies to only the doubletransceive r BTS and the correspon ding distribute d BTS.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

This parameter is related to the actual physical connectio Less than n of the 5 minutes BC. This parameter is modified only when the NSVC service is faulty. If this parameter is set to a small value, the detection of service type is sensitive and may lead to ping-pong handover between different services.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, call drops may occur due to delayed handover; if this parameter is set to a greater value, unnecess ary handover may be performe d, thus affecting the voice quality.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, down power adjustme nt may not be performe d when the downlink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, down power adjustme nt may be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, up power adjustme nt may be performe d when the downlink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, up power adjustme nt may not be performe d when

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The throughpu t of the GPRS service is affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, down power adjustme nt may not be performe d when the downlink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, down power adjustme nt may be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, up power adjustme nt may be performe d when the downlink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, up power adjustme nt may not be performe d when

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Generally, the value of this parameter does not need adjustme nt. It is the lower limit for adjusting the value of DLLongT ermFERT arget.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

This parameter is used for the adaptive adjustme nt function of AMR downlink threshold. When the voice is in poor performa nce not being affected by the channel quality: If the low rate mode is more used in the adaptatio n, you can increase the value of this parameter ; if the Generally, the value of this parameter does not need adjustme nt. It is the upper limit for adjusting the value of DLLongT ermFERT arget.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

Generally, the value of this parameter is fixed to 2, with no need of adjustme nt. The value of this parameter decides only the adjustme nt value or the adjusting frequency of the threshold. That is, the greater the value of this parameter is, the more frequently the threshold is adjusted.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a relatively small value, the fast power control on the downlink cannot be implemen ted. If this parameter is set to a relatively great value, the power control may be performe d excessive ly on the downlink, thus leading to poor quality, low level, and pingpong

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a relatively small value, call drops may occur due to delayed power control in the downlink. If this parameter is set to a relatively great value, the power control may be performe d excessive ly on the downlink, thus leading to ping-pong power

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, downlink power control may not be performe d when the voice quality is good, thus causing the power waste and increasing the interferen ce. If this parameter is set to a greater value, downlink power control may be performe d when the voice

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, uplink power control may not be performe d when the voice quality is bad, thus affecting the voice quality. If this parameter is set to a smaller value, uplink power control may be performe d when the voice quality is good, thus causing

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, handover may not be performe d when the downlink voice quality is bad, thus leading to call drops. If this parameter is set to a smaller value, unnecess ary handover s may be performe d, thus decreasin g the user experienc e and network traffic

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The setting of this parameter affects the triggering of a handover for poor quality in an AMR full rate call. The smaller the value of this parameter is, the easier a downlink handover due to a poor quality occurs.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the handover s due to bad downlink quality may increase, thus decreasin g the handover success rate. If this parameter is set to a greater value, handover s due to bad downlink quality are less possible to occur, thus increasing the call

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The setting of this parameter affects the triggering of a handover for poor quality in an AMR half rate call. The smaller the value of this parameter is, the easier a downlink handover due to a poor quality occurs.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the handover s due to bad downlink quality may increase, thus decreasin g the handover success rate. If this parameter is set to a greater value, handover s due to bad downlink quality are less possible to occur, thus increasing the call

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, decrease power control may not be performe d when the downlink level is high, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, decrease power control may be performe d when the

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, increase power control may be performe d when the downlink level is high, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, increase power control may not be performe d when the

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, decrease power control may not be performe d when the downlink level is high, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, decrease power control may be performe d when the

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, increase power control may be performe d when the downlink level is high, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, increase power control may not be performe d when the

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set improperl y to a small value, the downlink assignme nt BSC6900 procedure V900R01 Radio may fail. 1 Therefore , it is recomme nded that this parameter be greater than 80 ms.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The coding rate and MOS are affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The coding rate and MOS are affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The coding rate and MOS are affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The downlink power control (at the BTS side) can support up to 15 levels, in each of which the power of 2 dB is dynamical ly controlled .

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

During upgrade, pay more attention to the setting of this parameter . Be sure to check it. If an area is allowed for receiving short message s, set this parameter to NO. If the value of this parameter is YES, the MS in either idle or connecte d mode cannot occupy radio channel

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

The parameter modificati on has no None None impact on the equipmen t. As the double antenna gain increases, If you do the The not use a downlink parameter dualpower modificati antenna increases; on has no to receive as the impact on signals, double the set this antenna equipmen parameter gain t. to 0. decrease s, the downlink power decrease s.

Versions earlier than Equipmen BSC6900 t V900R01 1

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than 10 None minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

1. The block of A interface must be configure d. 2. If A over IP is configure d, the configurat ion does not support the operation.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The priority of the signaling link should be the highest.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The existing networkin g can be affected when the relation between the VLAN and the DSCP are reset.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

The parameter Not cannot be involved modified. None Not involved

The parameter modificati on has no None impact on the equipmen t. None

BSC6900 Equipmen V900R01 t 1 Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter Not cannot be involved modified.

Not involved

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

It is used for interworki ng with products of other manufact urers.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The address must exist and respond to the PING request.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the correspon ding neighbori ng 3G cell may be difficult to become the candidate neighbori ng cell of the serving cell. In this way, call drops may occur because the handover s may not be performe d timely. If this parameter is set to a smaller

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

It is recomme nded that this parameter be set to Yes on a multiband cell.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

1. If you set the start date or end date of daylight saving time (DST) to a day of the week after a specific date, the specific date must be six days or more days prior to the last day of the month. For example, the last day of October is the 31st day. Then, the specific date cannot be

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

BSC6900 Equipmen V900R01 t 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater or a smaller value, the balance between the traffic volume on the overlaid subcell and that on the underlaid subcell may not be achieved.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a smaller value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a smaller value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may

Versions earlier than Radio BSC6900 V900R01 1

BSC6900 Equipmen V900R01 t 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

For the modificati on of the parameter , See the ITU-T Q704.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The value of this parameter must be the same at both the BSS side and the NSS side. Whether the BSC6900 is encrypted and the chosen encryptio n algorithm type must be described in the MAP function process of the MSC. When setting the encryptio n

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

1. The block of A interface must be configure d. 2. If A over IP is configure d, the configurat ion does not support the operation. 3. The difference between the end CIC and the start CIC is smaller

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

1. The block of Ater interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

1. The block of A interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not allowed to

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the underlaid subcell; if this parameter is set to a smaller value, congestio n may occur in the overlaid subcell.

Versions earlier than Radio BSC6900 V900R01 1

Less than 10 None minutes

The parameter modificati on has no impact on the equipmen t.

The number of block retransmi ssions is BSC6900 Equipmen decrease V900R01 t d and the 1 throughpu t is increased .

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, congestio n may occur in the underlaid subcell in a short time; if this parameter is set to a greater value, congestio n in the overlaid subcell is difficult to be relieved.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the underlaid subcell in a short time; if this parameter is set to a smaller value, congestio n in the overlaid subcell is difficult to

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, traffic load on the underlaid subcell is increased , and thus congestio n may occur in the underlaid subcell. If this parameter is set to a smaller value, traffic load on the overlaid subcell is increased , and thus congestio n may occur in the

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the congestio n relieving speed in the underlaid subcell is decrease d. If this parameter is set to a smaller value, traffic load on the overlaid subcell is increased , and thus congestio n may occur in the overlaid subcell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to NO, the forced handover and call delay caused by timeslot arrangem ent can be avoided, but this may cause some TCHFonly calls to fail. If this parameter is set to Yes, calls may fail when the timeslot arrangem ent fails and when the MS does not select the

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n in the underlaid subcell may not be relieved in time. If this parameter is set to a smaller value, many calls may be handed over from the underlaid subcell to the overlaid subcell in a shot period, thus causing network If this

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The radio link should be reestablishe d after the parameter modificati on.

parameter is set to OPEN, the speech BSC6900 quality Equipmen V900R01 can be t improved 1 when the signal strength is low on the air interface.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified.

None

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. If this timer is set to a greater value, channel resources may be wasted, The thus parameter causing modificati congestio on has no None n. impact on If this the timer is equipmen set to a t. smaller value, the success rate of immediat e assignme nt may decrease.

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Equipmen BSC6900 t V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None.

The parameter modificati on has no None. impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the effectiven ess of power control is reduced, and thus the network interferen ce can not be reduced effectively . If this parameter is set to a smaller value, call drops may occur due to excessive power If this parameter is set to a greater value, the effectiven ess of power control is reduced, and thus the network interferen ce can not be reduced effectively . If this parameter is set to a smaller value, call drops may occur due to excessive power

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If the value of this parameter is too small, extension measure ment reports are sent frequently . If the value is too large, feedback informatio n may not be sent promptly in fewer extension measure ment

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 1 minute

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, call drops may occur due to no suitable neighbori ng cell for handover. If this parameter is set to a smaller value, handover success rate may be decrease d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The board should be reset to validate None the parameter modificati on.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The Not parameter involved cannot be modified. Negotiatio n can succeed Interrupt only when the the service configurat until ion is negotiate consistent successfu on the lly again. local and peer ends.

Not involved

None

Versions earlier than Transport BSC6900 V900R01

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Negotiatio n can succeed only when the configurat ion is consistent on the local and peer ends.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati Not on has no None None involved impact on the equipmen t. This The BTS parameter should be can be reset to modified Less than validate only when None 5 minutes the the BTS parameter is modificati deactivate on. d.

BSC6900 Equipmen V900R01 t 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Interrupt the service until negotiate successfu lly again. Interrupt the service until negotiate successfu lly again.

Negotiatio n fails if this parameter is modified. Negotiatio n fails if this parameter is modified.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The value ranges of frequency numbers vary with correspon ding band reporting.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter affects only the statistical BSC6900 result of V900R01 Radio the 1 counter "FER I (I = 0-7) Quality Level N".

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter affects only the statistical BSC6900 result of V900R01 Radio the 1 counter "FER I (I = 0-7) Quality Level N".

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter affects only the statistical BSC6900 result of V900R01 Radio the 1 counter "FER I (I = 0-7) Quality Level N".

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter affects only the statistical BSC6900 result of V900R01 Radio the 1 counter "FER I (I = 0-7) Quality Level N".

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter affects only the statistical BSC6900 result of V900R01 Radio the 1 counter "FER I (I = 0-7) Quality Level N".

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter affects only the statistical BSC6900 result of V900R01 Radio the 1 counter "FER I (I = 0-7) Quality Level N".

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter affects only the statistical BSC6900 result of V900R01 Radio the 1 counter "FER I (I = 0-7) Quality Level N".

You must deactivate the cell before modifying this parameter Less than and 5 minutes activate the cell after modifying this parameter .

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If this parameter is set to a small value, error is likely to occur during the detection of the burst packets.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

The parameter modificati Not on has no None None involved impact on the equipmen Negotiatio t. n can succeed The Interrupt only when parameter the the modificati service configurat on has no until None ion is impact on negotiate consistent the successfu on the equipmen lly again. local and t. peer ends. Negotiatio n can succeed only when the configurat ion is consistent on the local and peer ends. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. None

Versions earlier than Transport BSC6900 V900R01 1

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The default value of "MS_TXP WR_MAX _CCH" in the GSM900 and GSM850 cells is 5; the default value of "MS_TXP WR_MAX _CCH" in the DCS1800 and PCS1900 cells is 0.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

In "EXP ELABEL", the "FN" parameter cannot be a space or any of the following character s: '@', '#', '!', '%', '^', '&', '*', '[', ']', '\'', '\\'.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The radio link should be reestablis hed after None the parameter modificati on. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

When this parameter is set to YES, during the channel activation of the BSC6900, if the allocated channel speech version is full rate speech version 1 whereas the MS supports full rate speech version 2, the BSC6900 changes the speech version to full rate speech version 2 and sends it to

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to YES, the speech quality is improved.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The adjacent node ID must be configure d.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

No_HC: disable the header compress ion function; RTP/UDP /IP_HC: enable the RTP/UDP /IP/PPP

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

For a BTS of the BTS3X series, the value of this parameter is invalid.

The parameter modificati on has no impact on the equipmen t.

This technolog y prevents the loss of measure ment reports caused by the BSIC that cannot be decoded, improves the system performa nce, and ensures the radio handover success rate of the BSC6900.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The discontinu ous transmissi on (DTX) function allows a transmitte r to stop power transmissi on in the case of no voice transfer. This function has the following benefits: In the uplink: decreasin g the power consumpti on of the MS and reducing system interferen ce In the downlink:

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The value range of this parameter Less than depends 1 minute on the frequency range of the cell band. If the BCCH frequency of a cell is changed, the BSC6900 Less than forcibly 5 minutes hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 5 minutes

Less than 5 minutes

Less than 5 minutes

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in this cell to another cell and then resets this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The setting of this parameter must be consistent with the actual frequency reuse pattern of the TRX. Otherwise , the speech quality will be bad.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid in only the cells in the coverage area of the BTS3X.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The parameter modificati Not on has no None None involved impact on the equipmen t. This The BTS parameter should be can be reset to modified Less than validate only when None 5 minutes the the BTS parameter is modificati deactivate on. d. The parameter modificati Not on has no None None involved impact on the equipmen t.

The discontinu ous transmissi on (DTX) function allows a transmitte r to stop power transmissi on in the case of no voice transfer. This function has the following benefits: In the uplink: decreasin g the power consumpti on of the MS and reducing system interferen ce In the downlink:

Versions earlier than Radio BSC6900 V900R01 1

BSC6900 Equipmen V900R01 t 1

Versions earlier than Radio BSC6900 V900R01 1

BSC6900 Equipmen V900R01 t 1

This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

Not involved

None

The BTS should be reset to validate None the parameter modificati on. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The FACTOR TABLE must be configure d.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01

Not involved

Not involved

The parameter cannot be modified. The parameter cannot be modified.

Not involved

None

Not involved

None If this parameter is set to a greater value, the voice quality may be decrease d. If this parameter is set to a smaller value, the congestio n relieving capability may be decrease

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the duration of an AMR TCHFTCHH handover is short after the handover is triggered. Thus, few MSs can be handed over from TCHF to TCHH, and the congestio n relieving capability is decrease d. If this parameter is set to a greater If this parameter is set to a greater value, the handover cannot be performe d in time and network congestio n may occur. If this parameter is set to a smaller value, unnecess ary handover s may be

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, network congestio n may occur because the handover may not be performe d timely. If this parameter is set to a smaller value, the voice quality may be If this parameter is set to a smaller value, the handover zone is enlarged in a short time, and thus many MSs are handed over from TCHF to TCHH. If this parameter is set to a greater value, the handover zone is enlarged slowly and it takes a long time to initiate a TCHFTCHH handover. Thus, and

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a smaller value, network congestio n may occur because the handover may not be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter determine s whether to load data from the OMU or the FLASH when the BSC6900 or the board is restarted. The equipmen t is affected.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The value of this parameter is valid only for the BTSs of the doubletransceive r series and the distribute d BTSs.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

PS service of the cell will be interrupt until this parameter None is set to "SupportA sInnPcu" or "SupportA sExtPcu.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than 10 None minutes

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified.

None

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

BSC6900 V900R01 Radio 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. If this parameter is set to a greater value, only an MS close to the overlaid subcell can be assigned TCHHs. The Thus, parameter timeslots modificati are on has no wasted. impact on If this the parameter equipmen is set to a t. smaller value, an MS of bad quality on the edge of the overlaid subcell cannot be handed over from TCHH to TCHF. Thus, the

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the TCHH-toTCHF handover cannot be performe d in time, thus the voice quality is decrease d. If this parameter is set to a smaller value, unnecess ary handover s may be performe

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, only MSs in the center area of the overlaid subcell can be assigned TCHHs. Thus, timeslots are wasted and the congestio n relieving capability is decrease d. If this parameter is set to a smaller value, MSs on the edge of the If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a greater value, the handover cannot be performe d in time, and thus the voice quality is decrease

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the MS takes a longer time to meet the conditions for triggering the handover and the handover cannot be performe d in time. Thus, call drops may occur or more handover s are triggered. If this parameter is set to a smaller value, the MS takes a shorter If this parameter is set to a greater value, congestio n may occur in the macro cell. If this parameter is set to a smaller value, the handover cannot be performe d in time. Thus, call drops may occur or more handover s are

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is supported only by the BTS3002 C.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3002 C.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If the TRXs in a cell under this BSC6900 are at a frequency on DCS1800 , this parameter cannot be set to PCS1900, and vice versa.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

When this parameter is set to No, Highest Priority cannot be configure d.

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter limits the number of candidate cells. If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells and call drops may occur. If this parameter is set to a smaller value, an unwanted cell may become the candidate cell, thus leading to

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

This parameter limits the number of candidate cells. If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells and call drops may occur. If this parameter is set to a smaller value, an unwanted cell may become the candidate cell, thus leading to

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to YES, the probability of MS handover to the cell in the BSC6900 direction V900R01 Radio opposite 1 to the moving direction during fast handover is reduced.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a great value, there are BSC6900 strict V900R01 Radio restriction 1 s on the judgemen t of the MS moving direction.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a great value, there are BSC6900 strict V900R01 Radio restriction 1 s on the judgemen t of the MS moving direction.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, unnecess ary handover s may be performe d. If this parameter is set to a greater value, call drops may occur because the handover may not be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe If this parameter is set to a greater value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a too great value, the handover cannot be performe d timely, and the speech quality is deteriorat ed or call drop occurs. If this parameter is set to a too small value, unnecess ary handover s may be performe d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, call drops may occur because the handover may not be performe d timely. If this parameter is set to a smaller value, unnecess ary handover s may be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, call drops may occur because the handover may not be performe d timely. If this parameter is set to a greater value, unnecess ary handover s may be performe d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the underlaid subcell. If this parameter is set to a smaller value, ping-pong handover s may occur.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The value of this Not parameter involved cannot be changed.

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

The value of this parameter must be the same as the attribute Less than value of 1 minute the TRX frequency hopping of this frequency hopping group.

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to YES, the probability that the BTS transmits at full power increases. This increases the interferen ce but the handover success rate also increases.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 1 minute

The cell should be activated after the None parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

After this parameter is modified, the services in the cell are handed Less than over 1 minute forcedly. The cell is reset after all the handover succeeds or after ten seconds.

The cell should be activated after the parameter modificati on.

If this parameter is set to "NO_FH", the antiinterferen ce capability of the TRX is decrease d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighbori ng cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again,

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a too great value, the handover cannot be performe d timely, and the speech quality is deteriorat ed or call drop occurs. If this parameter is set to a too small value, unnecess ary handover s may be performe d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a smaller value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a smaller value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a smaller value, call drops may occur because the handover may not be

Versions earlier than Radio BSC6900 V900R01 1

The services are interrupte d until the signaling point is available.

Before the modificati on, the cell mapping table bound to the signaling point must be deleted.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Set this parameter properly to ensure that hierarchic al handover and loadbased handover can function properly. During hierarchic al handover and loadbased handover, the downlink received level of the target cell must be greater than this threshold.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, unnecess ary handover s may be performe d. If this parameter is set to a greater value, call drops may occur because the handover may not be

Versions earlier than Radio BSC6900 V900R01 1

Less than None 1 minute

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 1 minute

The cell should be activated after the None parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The discontinu ous transmissi on (DTX) function allows a transmitte r to stop power transmissi on in the case of no voice transfer. This function has the following benefits: In the uplink: decreasin g the power consumpti on of the MS and reducing system interferen ce In the downlink:

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The discontinu ous transmissi on (DTX) function allows a transmitte r to stop power transmissi on in the case of no voice transfer. This function has the following benefits: In the uplink: decreasin g the power consumpti on of the MS and reducing system interferen ce In the downlink:

Versions earlier than Radio BSC6900 V900R01 1

HSNs are optional for the cells with frequency hopping enabled. The cells in the same Less than frequency 1 minute group must use different HSNs. The HSNs of all the channels in a cell must be the same.

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

For details of the timer, see ITU-T Q.714. The modificati on is not recomme nded.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

For details of the timer, see ITU-T Q.714. The modificati on is not recomme nded.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the network interferen ce is increased ; if this parameter is set to a greater value, congestio n may occur in the cell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the network interferen ce is increased ; if this parameter is set to a greater value, congestio n may occur in the cell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the call duration is prolonged BSC6900 ; if this V900R01 Radio parameter 1 is set to a smaller value, the IBCA estimation accuracy is reduced.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover duration is prolonged and thus the handover BSC6900 cannot be V900R01 Radio performe 1 d in time; if this parameter is set to a smaller value, the IBCA estimation accuracy is reduced.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the network interferen ce is increased ; if this parameter is set to a greater value, congestio n may occur in the cell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover duration is prolonged and thus the handover BSC6900 cannot be V900R01 Radio performe 1 d in time; if this parameter is set to a smaller value, the IBCA estimation accuracy is reduced.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the network interferen ce is increased ; if this parameter is set to a greater value, congestio n may occur in the cell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the accuracy of interferen ce assessme nt in the IBCA algorithm may be reduced; if this parameter is set to a smaller value, the CPU occupanc y for IBCA algorithm is increased .

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter IBCA Allowed of the serving cell and the neighbor cell should be set to Yes before the configurat ion of this parameter .

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover duration is prolonged and thus the handover BSC6900 cannot be V900R01 Radio performe 1 d in time; if this parameter is set to a smaller value, the IBCA estimation accuracy is reduced.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the accuracy of interferen ce assessme nt in the IBCA algorithm may be reduced; if this parameter is set to a smaller value, the CPU occupanc y for IBCA algorithm is increased .

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to YES, cell congestio n may occur when the interferen ce is strong.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the network interferen ce is increased ; if this parameter is set to a greater value, congestio n may occur in the cell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

When the network status is poor, the packet length should not be too large. Otherwise , the path state is affected.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value and conseque ntly there is a small number of requests for SDCCHs, the SDCCHs of a cell are in idle state and the TCH traffic volume during busy time is decrease d. if this parameter is set to a smaller value and conseque ntly there is a large number of

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier Equipmen than t BSC6900 V900R01

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this timer is set to a greater value, channel resources may be wasted, thus causing congestio n.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the callcompletio n rate of MS increases but the BSC6900 load may also increase. If this parameter is set to a smaller value, the increase of the call completio n rate is not obvious.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the callcompletio n rate of MS increases but the BSC6900 load may also increase. If this parameter is set to a smaller value, the increase of the call completio n rate is not obvious.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to YES, the call completio n rate of the MS increases but the BSC6900 load also increases.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the channel load may increase and the access success rate may decrease.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, channel resources may be wasted, thus causing congestio n. If this parameter is set to a smaller value, the handover success rate may decrease.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the traffic volume during busy time may be decrease d. If this parameter is set to a smaller value, the voice quality may be decrease d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the traffic volume during busy time may be decrease d. If this parameter is set to a smaller value, the voice quality may be decrease d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter must be equal to or less than "OUTHO PWROVE RLOADT HRESHO LD" to protect the other timeslots/ cells from overload and underpow er.

The parameter modificati on has no impact on the equipmen t.

If the value of this parameter is set too high, the power load of other timeslots or cells is burdened.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The setting of this parameter affects the MOS. When the C/I ratio is satisfactor y, the coding scheme of higher rate is recomme nded; otherwise, the coding scheme of lower rate is recomme nded.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The setting of this parameter affects the MOS. When the C/I ratio is satisfactor y, the coding scheme of higher rate is recomme nded; otherwise, the coding scheme of lower rate is recomme nded.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The setting of this parameter affects the MOS. When the C/I ratio is satisfactor y, the coding scheme of higher rate is recomme nded; BSC6900 otherwise, V900R01 Radio the 1 coding scheme of lower rate is recomme nded. This parameter does not take effect in A over IP mode. In A over IP mode, the TC is

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the underlaid subcell in a short time; if this parameter is set to a smaller value, congestio n in the overlaid subcell is difficult to

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The Not parameter involved cannot be modified. This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

Not involved

None

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on. The BTS should be reset to validate None the parameter modificati on. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01

Less than 5 minutes

Not involved

Less than 5 minutes

This parameter can be modified only when the BTS is deactivate d. The parameter cannot be modified. This parameter can be modified only when the BTS is deactivate d.

The BTS should be reset to validate None the parameter modificati on. Not involved None

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The BTS should be reset to validate None the parameter modificati on. The parameter modificati on has no None impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, call drops may occur. If this parameter is set to a smaller value, handover may be performe d frequently and the signaling load in the cell is

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time. Thus, the voice quality is decrease d and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a smaller value, the handover cannot be performe d in time, thus the voice quality is decrease d or call drops may occur.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

1. Interferen ce band 0 is not counted in the traffic statistics. 2. In the following BTSs, the value range of this parameter is 115 to 85: BTS2X of all the versions, BTS3X 03.1130 of the earlier versions, 3001C07. 0301 of the earlier versions, and 3002C02. 0820 of the earlier versions.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not Involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a relatively small value, the calls with low BSC6900 receive V900R01 Radio level are 1 handed over to other cells. Thus, the handover success rate is

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a relatively great value, congestio n occurs to interRAT neighbori ng cells in a short time. If this parameter is set to a relatively small value, the congestio n in the current cell If this parameter is set to a relatively great value, congestio n occurs to interRAT neighbori ng cells in a short time. If this parameter is set to a relatively small value, the congestio n in the current cell

BSC6900 V900R01 Radio 1

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a relatively small value, the calls with low BSC6900 receive V900R01 Radio level are 1 handed over to other cells. Thus, the handover success rate is

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The loopback keeps interruptin g the None services until the loopback is cancelled.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. If this parameter is set to a greater value, congestio n may occur in the underlaid subcell; If this parameter is set to a smaller value, handover success rate may be decrease d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this timer is set to a greater value, channel resources may be wasted, thus causing congestio n. If this timer is set to a smaller value, the handover success rate may decrease.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this timer is set to a greater value, channel resources may be wasted, thus causing congestio n. If this timer is set to a smaller value, the handover success rate may decrease.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a relatively great value, the congestio n in the current cell cannot be solved. If this parameter BSC6900 is set to a V900R01 Radio relatively 1 small value, the calls with low receive level are handed over to other cells. Thus, the handover success

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. BTS The should be reset to validate None the parameter modificati on.

BSC6900 V900R01 Radio 1

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier Equipmen than t BSC6900 V900R01

Services are interrupte d unless the NSVL configurat None ion is the same as the SGSN configurat ion at the BSC.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

The parameter Not cannot be involved modified.

None

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 1

Transport

Transport

Equipmen t

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Transport 1

Negotiatio n can succeed Interrupt only when the the service configurat until ion is negotiate consistent successfu on the lly again. local and peer ends. No_HC: disable the header compress ion function; RTP/UDP /IP_HC: enable the RTP/UDP /IP/PPP

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. This The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

parameter depends on the type of Less than the actual 5 minutes physical IP transport cable of the BTS.

BSC6900 V900R01 Transport 1

This parameter must be set according to the Less than medium 5 minutes type of the actual IP transmissi on cable used by the BTS.

The BTS should be reset to validate None the parameter modificati on.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Each cell can be configure d with Less than only one 1 minute TRX that carries the main BCCH.

The cell should be activated after the None parameter modificati on. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter IPPATH must be configure d in advance.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

If the mode is not consistent , will interrupt service until it is consistent .

The setting of this parameter must be consistent with that on the peer.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

If the mode is not consistent , will interrupt service until it is consistent .

The setting of this parameter must be consistent with that on the peer.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

If the mode is not consistent , will interrupt service until it is consistent

The setting of this parameter must be consistent with that on the peer.

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

If the mode is not consistent , will interrupt service until it is consistent .

The setting of this parameter must be consistent with that on the peer.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

If the mode is not consistent , will interrupt service until it is consistent .

The setting of this parameter must be consistent with that on the peer.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

If the mode is not consistent , will interrupt service until it is consistent

Not involved

The setting of this parameter must be consistent with that on the peer. It is used for interworki ng with products of other manufact urers.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

1. This command is applicable to the boards AOUa, POUa, AOUc, POUc, and OIUa. 2. It is used for interworki ng with products of other manufact urers.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

1. This command is applicable to the boards AOUa and POUa. 2. It is used for interworki ng with products of other manufact urers.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

If the mode is not consistent , will interrupt service until it is consistent .

The setting of this parameter must be negotiate d with that on the interconn ected side.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The setting of Interrupt this the parameter service must be until negotiate negotiate d with that successfu on the lly again. interconn ected side.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Interrupt the service until None negotiate successfu lly again.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Not involved

The parameter cannot be modified. The parameter cannot be modified.

Not involved

None

Not involved

None

Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01

Equipmen t

Equipmen t

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not None. involved.

The parameter modificati on has no impact on the equipmen t.

This parameter BSC6900 adjusts V900R01 Radio traffic 1 distributio n.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. None

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the macro subcell; If this parameter is set to a smaller value, unnecess ary handover s may be performe d, thus the voice quality is decrease d and ping-pong handover s may be performe d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d, thus the voice quality is decrease d and ping-pong handover may occur. If this parameter is set to a smaller value, congestio n may occur in the macro subcell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

None

Not involved

This parameter must be less than "UHUMT HD".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Interrupt the service until negotiate successfu lly again.

The setting of this parameter must be consistent with that on the peer.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

According to the MTP3 load sharing principle, the link selection mask must be set properly. If the value is not set properly, the load sharing between MTP3 links may fail.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The mask is calculated according to the link set to a destinatio n entity.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a too small value, the correspon ding cell may reject some handover requests; thus the traffic congestio n on the neighbori ng cells with heavy traffic cannot be relieved. If this parameter is set to a too great value, the correspon ding cell may be overloade d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid only when "NC2Loa dResel" is set to SUPPOR T.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not None. involved.

This parameter BSC6900 adjusts V900R01 Radio traffic 1 distributio n.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter BSC6900 adjusts V900R01 Radio traffic 1 distributio n.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, it is difficult for the MS to be handed over to the serving cell, thus leading to call drop when there is no suitable neighbori ng cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the serving cell again,

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, it is difficult for the MS to be handed over to the serving cell, thus leading to call drop when there is no suitable neighbori ng cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the serving cell again,

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the neighbori ng cells in a short time; if this parameter is set to a smaller value, congestio n in the serving cell is difficult to be relieved.

Versions earlier than Radio BSC6900 V900R01 1

The reciprocal of the parameter value is Not the ratio involved. of the MSs to perform a load handover.

The parameter modificati on has no impact on the equipmen t.

This parameter BSC6900 adjusts V900R01 Radio traffic 1 distributio n.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The function of cell load reselectio n is valid only when "NC2Loa dResel" in "SET BSCPSS OFTPAR A" is set to Support and "LOADRE SELALLO W"is set to Permit.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not None. involved.

The parameter modificati on has no impact on the equipmen t.

This parameter BSC6900 adjusts V900R01 Radio traffic 1 distributio n.

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The local IP address and peer IP must be configure d in the same network segment. The peer IP address cannot be the same with the local IP address

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on. The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier Equipmen than t BSC6900 V900R01

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

The services are interrupte d until the SCTP link is working normally.

The both end address of the SCTP is the parameter for the interconn ection. The value can be modified after the negotiatio n with the peer system.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The services are interrupte d until the SCTP link is working normally.

The both end address of the SCTP is the parameter for the interconn ection. The value can be modified after the negotiatio n with the peer system.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The services are interrupte d until the SCTP link is working normally.

The parameter can be modified when "MODE" in the command "ADD SCTPLN K" is set to Client.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The services are interrupte d until the SCTP link is working normally.

It is valid when "LOGPO RTFLAG[/ PARA in the command "ADD SCTPLN K" is ON.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The services are interrupte d until the SCTP link is working normally.

It is valid when "LOGPO RTFLAG[/ PARA in the command "ADD SCTPLN K" is ON.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Not involved

The parameter cannot be modified. The parameter cannot be modified.

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01

Equipmen t

Equipmen t

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

When the peer end unconditio nally changes the bits in the check message, the services will not resume unless the switch is set to OFF.

1. When the peer end unconditio nally changes the bits in the check message, the services are disrupted if the switch is set to ON. 2. When the switch is set to OFF, the alarm "Inconsist ent Configura tions at the Two Ends of the Link over the Ater Interface" will not be reported.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

If this parameter is set to REMOTE _LOOP and LOCAL_L OOP, the service on this link is affected until the loopback The is loopback cancelled. keeps When the interruptin upper g the layer services bearer is until it is IMAGRP, cancelled. IMAGRP is reset after the loopback is canceled. Otherwise , the state of the IMAGRP is abnormal and upper layer

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

When the loopback type is changed to REMOTE _LOOP or LOCAL_L OOP, the service is affected. The service The becomes loopback normal keeps when the interruptin loopback g the test is services canceled. until it is When the cancelled. loopback type is set to LOCAL_L OOP, you cannot directly change it to REMOTE _LOOP. You must change it to

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

For the BTS3002 C, if each cell is configure d with two TRXs (O2 or S2) and the value of this parameter is YES, the radio frequency (RF) connectio n supports the configurat ion of the main diversity antennas. Only the BTS3002 C has this

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to "ON" and the level of the channel request received by the BSC6900 is low, the BSC6900 assigns only an underlaid channel to the MS. In the case of heavy traffic, this may lead to congestio n in the underlaid subcell but can prevent call drops due to the excessive ly low

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter must be less than "UTEMTH D".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Generally, the value of this parameter does not need adjustme nt. It is the lower limit for adjusting the value of LongTerm FERTarg et.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The value of this parameter decides whether the threshold is adjusted upwards or downward s. When the voice is in poor performa nce (excluding the cause of poor channel quality: If the low rate mode is more used in the adaptatio n, you can increase the value of this parameter Generally, the value of this parameter does not need adjustme nt. It is the upper limit for adjusting the value of LongTerm FERTarg et.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Generally, the value of this parameter is fixed to 2, with no need of adjustme nt. The value of this parameter decides only the adjustme nt value Not or the involved adjusting frequency of the threshold. That is, the greater the value of this parameter is, the more frequently the threshold is adjusted. The adjustme nt of the parameter Services setting are changes disrupted the until the service cells are distributio ren on the distribute DSPs. d The DSPs successfu without lly. LVDS links do not carry services.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The services are interrupte d until the SCTP link is working normally.

The parameter modificati on should be negotiate d with the peer end, and the BSC6900 should be reset after the modificati on. It is recomme nded that this parameter should not be modified when the system is running.

The BSC6900 should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

If there are fewer frequenci es in a frequency hopping group, the mode of Frequenc y List can decrease the length of an assignme nt or handover command to facilitate the access of an MS.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to YES, the network KPIs may be deteriorat ed.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to YES, the network KPIs may be deteriorat ed.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The transport path should be reNone establishe d after the parameter modificati on. The transport path should be reNone establishe d after the parameter modificati on.

Not involved

None

Less than None 5 minutes

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. If this parameter is set to a smaller value, call drops may occur due to delayed power control; if this parameter is set to a greater value, the power control may be performe d excessive ly, thus leading to ping-pong

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The modificati on of the parameter affects the sensitivity of the SCTP link detection. The larger the value is, the longer the link detection time is.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, call drops may occur or voice quality may be decrease d due to delayed handover; if this parameter is set to a greater value, unnecess ary handover may be performe d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

The adjacent node ID must be configure d.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

1. In the earlier versions of BSC6000 V900R00 8C01B06 0SP06 and BSC6000 V900R00 86C01B0 60SP06, a maximum of 50 BTSs can be download ed simultane ously on one BSC through the M2000 client. In BSC6000 V900R00 8C01B06 0SP06 and BSC6000 V900R00

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Interrupt the service until None negotiate successfu lly again.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The value of this parameter cannot be smaller than the maximum PPPMUX sub-frame length. The number sub-frame must be larger than 2 to enable the

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

The modificati on of the parameter affects the sensitivity of the SCTP link detection. The larger the value is, the longer the link detection time is.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

You can increase this value when the handover s are slow or the handover success ratio is low due to bad clock or transmissi on quality. For the handover s of an MS to succeed, the following condition must be met: "Physical informatio n MAX Retrans" x "Radio link invalid count" > Interval

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Interrupt the service until None negotiate successfu lly again.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

If the PPP frame length is larger than this value, PPPMUX multiplexi ng cannot be performe d. The value of this parameter cannot be larger than the maximum multiplexi ng frame length wMuxMfl and the number sub-frame must be larger than 2 as the enabling condition of PPPMUX

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the algorithm cannot realize fast power control. If this parameter is set to a greater value, the power control may be performe d excessive ly, thus leading to poor quality, low level, and pingpong power control..

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the algorithm cannot realize fast power control. If this parameter is set to a greater value, the power control may be performe d excessive ly, thus leading to poor quality, low level, and pingpong power control..

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the algorithm cannot realize fast power control. If this parameter is set to a greater value, the power control may be performe d excessive ly, thus leading to poor quality, low level, and pingpong power control..

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If this parameter is set to a smaller value, the handover success rate may be affected.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the call drop rate may increase; if this parameter is set to a greater value, the speech quality may be affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Before performin g singlepoint positionin g, you need to remove GPS configurat ion history records.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

If this parameter is set to a smaller value, call drops may occur due to delayed power control; if this parameter is set to a greater value, the power control may be performe d excessive ly, thus leading to ping-pong

Versions earlier than Radio BSC6900 V900R01 1

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no impact on the equipmen t.

In a multiband network, this parameter can be set on the basis of the traffic volume on each frequency band. If this parameter is set to 0, the MS reports the measure ment results of six neighbori ng cells known and permitted by the NCC at the bands with the best signal

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

This parameter is valid only when the MCPA algorithm is enabled.

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

In scenarios with heavy traffic, the BSC6900 network V900R01 Radio performa 1 nce can be improved if this switch is Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

The Enhanced Measure ment Report supports the measure ment of 3G neighbori ng cells to implemen t the interopera bility between the 2G system and 3G system, and thus ensures the

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t. The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter is used to limit the number of candidate cells for handover s. If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells, thus leading to call drops. If this parameter is set to a smaller value, an unwanted cell may become a candidate cell, thus

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the idle state of the current SDCCHs cannot be indicated correctly and conseque ntly the rollback of SDCCHs immediat ely triggers adjustme nt and affects the access success rate. If this parameter is set to a larger value, the channel allocation

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells, thus leading to call drops. If this parameter is set to a smaller value, an unwanted cell may become a candidate cell, thus leading to handover failures.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Not involved

To modify this parameter , run "STP GATEWA YCHK" first and then "STR GATEWA YCHK".

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. None

Not involved

The parameter Not cannot be involved modified.

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t.

Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 1

Transport

Transport

Transport

Transport

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The services are interrupte d until the SCTP link is working normally.

The local end of the SCTP link is the server and the applicatio n type is NBAP, the working mode should not be modified as the client. For the SCTP link of the M3UA applicatio n, the working mode can be modified only when the upper layer applicatio n is deleted.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

None

None

BSC6900 Equipmen V900R01 t 1

If the mode is not consistent , will interrupt service until it is consistent .

The setting of this parameter must be negotiate d with that on the interconn ected side.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The BTS should be reset to validate the parameter modificati on.

If the value of this parameter is set too high, the RSL congestio n is likely to occur.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Because the measure ment reports may not always be correctly decoded when the quality of a serving cell is poor, handover s may fail when the number of the lost measure ment reports exceeds the value set by this parameter . You can set a relatively larger value for this parameter , thus

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

When this parameter is set to Noreport, the BTSs do not submit measure ment reports to the BSC, which disables handover s and power control, and greatly impacts on the

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If the MSC pool function is enabled, and the value of this parameter is not NORMAL, the DPC is not selected for call access.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If the GSM BSC is connecte d to the GSM MSC, it is recomme nded that you set this parameter to R98_or_b elow. If the GSM BSC is connecte d to the UMTS MSC, it is recomme nded that you set this parameter to R99_or_a bove.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this timer is set to a greater value, the radio resources are occupied for a too long time, thus affecting the channel resource usage. If this timer is set to a smaller value, the call reestablis hment success rate

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter should be set as required: In the areas where the traffic volume is low, this parameter can be set to 4 or 7 to improve the success rate of MS access. In the areas where congestio n occurs or in the micro cells where the traffic volume is high, it is recomme nded this

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter limits the number of candidate cells. If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells and call drops may occur. If this parameter is set to a smaller value, an unwanted cell may become the candidate cell, thus leading to

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter modificati on has no None None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

If the mode is not consistent , will interrupt service until it is consistent

The interconn ection may be affected if this parameter is modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None.

The parameter modificati on has no None. impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None.

The parameter modificati on has no None. impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None.

The parameter modificati on has no None. impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If the value of this parameter is increased , the cell congestio n rate increases. If the value of this parameter is decrease d, oneway audio may persist

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If this parameter is set to YES, the call drop rate may increase.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Negotiatio n can succeed only when the configurat ion is consistent on the local and peer ends. Negotiatio n can succeed only when the configurat ion is consistent on the local and peer ends. The adjacent node ID must be configure d.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Only the BTS3X in G3BTS32 .30000.04 .1130 or later and the doubletransceive r BTSs support the LAPDm N200 parameter . If this parameter is set to Yes, the BSC6900 sends the LAPDm N200 parameter . If this parameter is set to OFF, the BSC6900 does not send the LAPDm N200

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to ENABLE, the MOS can be increased in a call between MSs.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid only when "NC2SPT " in "SET GCELLG PRS" is set to YES and "NCO" in "SET GCELLP SBASE" is set to NC2.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The most significant three bits of BSIC for all cells map with the NCC. NCC Permitted should be set properly to avoid too many call drops. The MS does not report the informatio n on the neighbori ng cells in the network whose correspon ding NCC bit is set to 0. Thus, this parameter should be set

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than 10 None minutes

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

Not involved

Not involved

The parameter cannot be modified. The parameter cannot be modified.

The parameter modificati on has no None impact on the equipmen t. Not involved None

If this parameter is set to a smaller value, handover s are performe d frequently ; if this parameter is set to a greater value, handover s cannot be performe d timely, thus leading to

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01

Equipmen t

Transport

Transport

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to YES, FR calls can be switched into HR calls to relieve the network congestio n, but the voice quality is decrease d; if this parameter is set to NO, FR calls cannot be switched into HR calls, that is, network congestio n cannot be relieved through the

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover margin is increased in a short period and many MSs are handed over from TCHF to TCHH, thus affecting the voice quality. If this parameter is set to a smaller value, the handover margin is enlarged slowly and it takes a long time to initiate a TCHF-

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, only MSs in the center of the cell can meet the handover condition. Thus, the network congestio n cannot be relieved in time. If this parameter is set to a smaller value, MSs at the edge of the cell can also meet the handover condition, thus affecting

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover margin is increased in a short period and many MSs are handed over from TCHF to TCHH, thus affecting the voice quality. If this parameter is set to a smaller value, the handover margin is enlarged slowly and it takes a long time to initiate a TCHF-

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, MSs at the edge of the cell can also meet the handover condition, thus affecting the voice quality. If this parameter is set to a smaller value, only MSs in the center of the cell can meet the handover condition. Thus, the network congestio n cannot be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, MSs with poor quality can also meet the handover condition, thus affecting the voice quality. If this parameter is set to a smaller value, little MSs can meet the handover condition. Thus, the network congestio n cannot be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the calls cannot be handed over to TCHH in a short period when the traffic volume is increased greatly. Thus, the network congestio n cannot be relieved in time. If this parameter is set to a smaller value, calls are handed over to TCHH unnecess

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, only MSs in the center of the cell use the TCHH, thus leading to timeslot waste and the network congestio n cannot be relieved in time. If this parameter is set to a smaller value, MSs at the edge of the cell and with poor quality also

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, MSs at the edge of the cell and with poor quality also cannot be handed over to the TCHF, thus affecting the voice quality. If this parameter is set to a smaller value, only MSs in the center of the cell use the TCHH, thus leading to

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, handover cannot be triggered even when the quality is poor, thus affecting the voice quality; if this parameter is set to a smaller value, handover is triggered even when the quality is good, thus the network congestio n cannot be relieved in

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, calls are handed over to TCHH unnecess arily, thus causing MOS loss of the customer; if this parameter is set to a greater value, TCHFTCHH handover is performe d only when the traffic volume is high, thus network

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The handover decision is allowed only when the uplink receive quality is greater than or equal to the value of this parameter . Therefore , if this parameter is set to a greater value, the handover s due to nodownlink measure ment report cannot be triggered.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the following dualdensity BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter should be set to a small value because the signaling channel seizure duration is shorter than the traffic channel seizure duration for the MS.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

If the value is too big, will interrupt service until it is set to the normal value.

If this parameter is set to a larger value, the bandwidth of the service is smaller.

Versions earlier than Transport BSC6900 V900R01 1

Negotiatio n can succeed Interrupt only when the the service configurat until ion is negotiate consistent successfu on the lly again. local and peer ends. Negotiatio n can succeed only when the configurat ion is consistent on the local and peer ends.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The transmissi on priority of the service is affected if the queue DSCP value of the port is modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The transmissi on priority of the service is affected if the queue DSCP value of the port is modified.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Not involved

If the parameter value is set relatively small, the sensitivity for detecting the OML when it is broken is improved. When the parameter value is set too small and if the link is intermitte ntly disconnec ted, misjudge ments may occur to the testing results. If the parameter value is The parameter cannot be modified.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Before modifying this parameter Less than , you 5 minutes must deactivate the cells bound to the OPC.

The cell should be activated after the None parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Primary operator index must be 0.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

1. The block of A interface must be configure d. 2. If A over IP is configure d, the configurat ion does not support the 1. The block of Ater interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

1. The block of A interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not allowed to

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the underlaid subcell; if this parameter is set to a smaller value, assignme nt success rate may be decrease d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, assignme nt success rate may be decrease d; if this parameter is set to a smaller value, congestio n may occur in the underlaid subcell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Interrupt the service until negotiate successfu lly again.

The setting of this parameter must be consistent with that on the peer.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If this parameter is set to a greater value, too many channel resources are occupied and the congestio n occurs. If this parameter is set to a smaller value, the handover success rate may fall.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If this parameter is set to a greater value, too many channel resources are occupied and the congestio n occurs. If this parameter is set to a smaller value, the handover success rate may fall.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the overlaid subcell; if this parameter is set to a smaller value, congestio n may occur in the underlaid subcell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the value of this parameter is set too small, frequent handover s are likely to occur.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the overlaid subcell; if this parameter is set to a smaller value, congestio n may occur in the underlaid subcell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. If this parameter is set to a greater value, congestio n may occur in the overlaid subcell in a short time; if this parameter is set to a smaller value, congestio n in the underlaid subcell is difficult to be relieved.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n in the underlaid subcell is difficult to be relieved; if this parameter is set to a smaller value, congestio n may occur in the overlaid subcell in a short time.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the overlaid subcell in a short time; if this parameter is set to a smaller value, congestio n in the underlaid subcell is difficult to

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the underlaid subcell; if this parameter is set to a smaller value, congestio n may occur in the overlaid subcell.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

The Not parameter Not None involved cannot be involved modified. The BTS should be reset to Less than validate None None 5 minutes the parameter modificati on. The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the underlaid BSC6900 subcell; if V900R01 Radio this 1 parameter is set to a smaller value, congestio n may occur in the overlaid subcell.

Not involved

None

The parameter modificati on has no None impact on the equipmen t. None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 BSC6900 V900R01 Transport 1

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified.

Not involved

None

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the BTS frequently reports overload indication message s to the BSC6900. As a result, the BSC6900 frequently reports overload indication message s to the MSC and thus the MSC may initiate flow control. If this parameter is set to a greater value, the BTS

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Not involved

Not involved

If this parameter is set to a greater value, the CPU may be overloade d. If this parameter is set to a smaller value, the call loss rate is high. If this parameter is set to a greater value, the CPU may be overloade d. If this parameter is set to a smaller value, the call loss rate is high. If this parameter is set to a greater value, the CPU may be overloade d. If this parameter is set to a smaller value, the call loss rate is high.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If this parameter is set to a greater value, the CPU may be overloade d. If this parameter is set to a smaller value, the call loss rate is high.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Properly setting this parameter can increase the paging success rate. If this parameter is set to a greater value, paging overload may occur and the paging success rate may decrease.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

Not involved

The parameter Not cannot be involved modified.

None

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d; if this parameter is set to a smaller value, handover s may not be performe d in time and call drops may occur.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified.

None

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Less than 15 None minutes

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on. BTS The should be reset to validate None the parameter modificati on. BTS The should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

Less than None 5 minutes

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The local IP address and peer IP must be configure d in the same network segment. The peer IP address cannot be the same with the local IP address

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

The services are interrupte d until the SCTP link is working normally.

The both end address of the SCTP is the parameter for the interconn ection. The value can be modified after the negotiatio n with the peer system.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The services are interrupte d until the SCTP link is working normally.

The both end address of the SCTP is the parameter for the interconn ection. The value can be modified after the negotiatio n with the peer system.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

The services are interrupte d until the SCTP link is working normally.

The SCTP port number is the parameter for the negotiatio n. The value can be modified after the negotiatio n with the peer

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the target cell for the previous handover will not be selected for the next handover, but the probability of call drop increases. If this parameter is set to a smaller value, the probability of handover

Versions earlier than Radio BSC6900 V900R01 1

Not involved

When the network status is poor, the check period should not be too small. Otherwise , the path state is affected.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Interrupt the service until negotiate successfu lly again.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Negotiatio n fails if this parameter is modified.

Interrupt the service until negotiate successfu lly again.

Negotiatio n fails if this parameter is modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

The SIGBVC must be reset after this switch is Less than turned on. 5 minutes The BSC supports the PFC when the SGSN supports the PFC.

The transport path should be reestablishe d after the parameter modificati on.

If this parameter is set to "YES", the user with high QoS requireme nt may occupy a great number of PS resources . In this case, the remaining resources for other users reduce. As a result, the KPIs for these users become

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If this parameter is set to a greater value, more paging message s are processe d. When the BSC6900 is overloade d, the control on the arrival rate of paging message s does not take effect. If this parameter is set to a smaller value, some paging message s that can be

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Not involved

If this parameter is set to a higher value, more PS paging message s can be processe d, thus increasing the BSC load. As a result, the control on the message arrival rate may fail to protect the BSC. If this parameter is set to a lower value, more PS paging message s are discarded , thus If this parameter is set to a smaller value, the control of the arrival rate of paging message s is sensitive. If this parameter is set to a greater value, the control is insensitiv e.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a lower BSC6900 value, the V900R01 Radio paging 1 success rate may decrease.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The adjacent node ID must be configure d.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The MS calculates C1 and C2 of the serving cell at a minimum interval of 5s. When necessary , the MS recalculates C1 and C2 of all nonserving cells (neighbori ng cells). The MS constantly checks whether a cell reselectio n is required by checking following conditions : Whether

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The loopback keeps interruptin g the None services until the loopback is cancelled. The loopback keeps interruptin g the None services until the loopback is cancelled.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid for the EDGE TRX only.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid for the EDGE TRX only.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is valid only for EDGE TRXs and is invalid for ordinary TRXs.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

If "Play switch" is set, the normal calls may be affected.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified. 1. The block of Ater interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

When the loopback type is changed to REMOTE _LOOP or LOCAL_L OOP, the service is affected. The service becomes normal when the loopback test is canceled. When the loopback type is set to LOCAL_L OOP, you cannot directly change it to REMOTE _LOOP. You must change it to

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

Not involved

The parameter Not cannot be involved modified.

The parameter modificati on has no None impact on the equipmen t. None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01

Not involved

1. This command is applicable to the boards AOUa and POUa. 2. It is used for interworki ng with products of other manufact urers.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

Not involved

Not involved

The parameter cannot be modified. The parameter cannot be modified. The parameter cannot be modified.

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 1

Equipmen t

Transport

Equipmen t

Transport

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on. The transport path should be reNone establishe d after the parameter modificati on. The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If this parameter is set to a greater value, the error is small.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on. The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter can be added and modified. It cannot be

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier than Transport BSC6900 V900R01 1

Not involved

ENABLE: the multiplexi ng frame function of the PPP link is enabled. DISABLE: the multiplexi ng frame function of the PPP link is disabled.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

This parameter can be added or modified but cannot be removed.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

When the sampling rate of preprocesse d measure ment reports is set to 1, The the parameter frequency modificati of on has no None submitting impact on prethe processe equipmen d t. measure ment reports should be set to one report per two seconds

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Each layer has 16 priorities, numbered 1-16 respective ly. If the number of the priority is small, the priority is high. This parameter along with Layer of the Cell determine s the priority of a cell. The priority affects the sequence of neighbori ng cells for handover. It also affects

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The routing priority is modified. In the case of multiple routes to the same signaling point, the route priority is

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Services are interrupte d until the parameter is None consistent with the SGSN at the peer end.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified. 1. This command is applicable to the boards AOUa and POUa. 2. It is used for interworki ng with products of other manufact urers.

None

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The modificati on of the parameter affects the adjacent node that is configure d with the factor table. After the successfu l modificati on, the parameter takes effect in the following two cases: 1. New access subscribe r. 2. Bandwidt h modificati

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The modificati on of the parameter affects the adjacent node that is configure d with the factor table. After the successfu l Not modificati involved on, the parameter takes effect in the following two cases: 1. New access subscribe r. 2. Bandwidt h modificati The SIGBVC must be reset after this switch is turned on. Less than The BSC 5 minutes supports the PS HO when the SGSN supports the PS HO.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The transport path should be reestablishe d after the parameter modificati on.

If this parameter is set to "YES", the delay BSC6900 Equipmen caused by V900R01 t cell 1 reselectio n decrease s.

Not involved

Not involved

The modificati on of the parameter affects the adjacent node configure d with the TRMMAP. After the successfu l modificati on, it is valid in the case of the new access of a subscribe r and the bandwidth modificati The modificati on of the parameter affects the adjacent node configure d with the TRMMAP. After the successfu l modificati on, it is valid in the case of the new access of a subscribe r and the bandwidth modificati

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

If this parameter is set to a larger value, more packets are discarded when the congestio n occurs. Thus, the priority value of the major service should be smaller than that of the minor service.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The modificati on of the parameter affects the adjacent node configure d with the TRMMAP. After the successfu l modificati on, it is valid in the case of the new access of a subscribe r and the bandwidth modificati

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The modificati on of the parameter affects the adjacent node configure d with the TRMMAP. After the successfu l modificati on, it is valid in the case of the new access of a subscribe r and the bandwidth modificati

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

If this parameter is set to a larger value, more packets are discarded when the congestio n occurs. Thus, the priority value of the major service should be smaller than that of the minor service.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

This parameter should be set on the basis of the actual receiver sensitivity of the BTS and the minimum access level of the MS to avoid the situation where a call cannot be made even though there are signals detected.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the call drop rate decrease s but the traffic volume and paging success rate are affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The setting of this parameter affects the GSM Phase II MS.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

The line code must be consistent with that on the interconn ected side. Interrupt HDB3 the (HDB3 service code) and until AMI (AMI negotiate code) are successfu used for lly again. E1 ports. B8ZS (B8ZS code) and AMI_ZCS (AMI code) are used for T1 ports.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Interrupt the service until negotiate successfu lly again.

The frame structure must be consistent with that on the interconn ected side.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Interrupt the service until negotiate successfu lly again.

The frame structure must be consistent with that on the interconn ected side.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Interrupt the service until negotiate successfu lly again.

The frame structure must be consistent with that on the interconn ected side.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the value of this parameter is set inappropri ately high or small, the BTS cabinet top output power is inconsiste nt with the TRX output power.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The transmissi on priority of the service is affected if the queue DSCP value of the port is modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The transmissi on priority of the service is affected if the queue DSCP value of the port is modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The transmissi on priority of the service is affected if the queue DSCP value of the port is modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The transmissi on priority of the service is affected if the queue DSCP value of the port is modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The transmissi on priority of the service is affected if the queue DSCP value of the port is modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s between micro cells are performe d, thus affecting the voice quality. If this parameter is set to a smaller value, congestio n may occur in macro cells.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in macro cells. If this parameter is set to a smaller value, unnecess ary handover s between micro cells are performe d, thus affecting the voice quality.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, downlink power insufficien cy may not be solved in time, thus leading to call drops. If this parameter is set to a smaller value, unnecess ary handover s may be performe d, thus the voice quality is decrease d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d, thus the voice quality is decrease d. If this parameter is set to a smaller value, downlink power insufficien cy may not be solved in time, thus leading to call drops.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the algorithm cannot realize fast power control. If this parameter is set to a greater value, the power control may be performe d excessive ly, thus leading to poor quality, low level, and pingpong

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is supported only by the BTS3012 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Less than None 5 minutes

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

This parameter should be set on the basis of the actual receiver sensitivity of the BTS and the minimum access level of the MS to avoid the situation where a call cannot be made even though there are signals detected.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the call drop rate decrease s but the traffic volume and paging success rate are affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

For the BTS3X series and doubletransceive r BTSs, this parameter does not affect MS access but affects the reporting of CCCH_L OAD_IND . If the level received by the BCCH on the network side is greater than the RACH Busy Threshold , the CCCH_L

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the random access success rate may decrease.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the BTS frequently sends the overload message s to the BSC6900. Thus, the system resource usage decrease s and MSs are difficult to access the network. If this parameter is set to a greater value, the BTS sends an overload message to the BSC6900

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the allowable error rate for the random access signal is high and an MS can easily access the network; however, the error report rate is high. If this parameter is set to a greater value, the error report rate of the MS is low but the MS cannot

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If this parameter is set to Algorithm I, the BTS performs AMR rate adaptatio n according to the C/I value. If this parameter is set to Algorithm II, the BTS performs AMR rate adaptatio n according to the BER value. Algorithm II is valid only for the EMR. If this parameter is set to None, the

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to on, the MOS of a BSC6900 MSV900R01 Radio initiated 1 and MSterminate d call is improved.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to YES, the BSC6900 initiates a reassign ment when receiving an assignme nt failure message over the Um interface. This helps increase the call completio n rate and improve the QoS of the network. The successfu l reassign ment, however, results in an

Versions earlier than Radio BSC6900 V900R01 1

Not involved

To improve the success rate of reassign ment, it is recomme nded that you use the default value Different Band. That is, the frequency band of the preferenti ally reassigne d channel is different from what

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier Equipmen than t BSC6900 V900R01

Not involved

None

Not involved

The parameter Not cannot be involved modified.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

The parameter must be set to a value smaller than the number of TCHs available on the BCCH TRX to prevent the frequent enabling and disabling of the power amplifier of a TRX.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The setting of this parameter requires negotiatio n with the MSC, so that the MSC can correctly process HO RQD message s.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati Not on has no None None involved impact on the equipmen Negotiatio t. n can succeed The Interrupt only when parameter the the modificati service configurat on has no until None ion is impact on negotiate consistent the successfu on the equipmen lly again. local and t. peer ends. Negotiatio n can succeed only when the configurat ion is consistent on the local and peer ends. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

The range of this parameter is determine d by the cell configurat ion. The lower limit is 0, and the upper limit is sum of TCHF, TCHH and Dynamic PDCH configure d in the cell.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, too many channels may be reserved for the users with high priority, and the users with low priority may be failed to access channels. If this parameter is set to a smaller value, channels reserved for the users with high priority may be insufficien

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If this parameter is set to a greater value, the BTS power decrease s too much. If this parameter is set to a smaller value, the BTS power decrease s insignifica ntly and thus the power decrease effect is unsatisfac tory.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the radio resource status is reported too frequently , thus increasing the load of the BSC6900. If this parameter is set to a greater value, the radio resource status is not immediat ely reported and thus the BSC6900 cannot handle the

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

The SIGBVC must be reset after this switch is Less than turned on. 5 minutes The BSC supports the RIM when the SGSN supports the RIM.

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the radio link is vulnerabl e to failure, thus call drops are likely to occur. If this parameter is set to a greater value, the MS may not release the connectio n for a long time, thus decreasin g the resource usage. The parameter is valid in

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The BSC should be reset to validate None the parameter modificati on.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. None

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01

Equipmen t

Equipmen t

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The resource group must exist.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, call drops may occur due to no suitable neighbori ng cell for handover. If this parameter is set to a smaller value, handover success rate may be decrease

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells, thus leading to call drops. If this parameter is set to a smaller value, an unwanted cell may become a candidate cell, thus leading to handover failures.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified. The parameter modificati on has no None impact on the equipmen t. The parameter Not cannot be involved modified. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

None

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 BSC6900 V900R01 Radio 1 Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The services are interrupte d until the signaling point is available.

The switch is off in the case of a signaling point to the single link. After the link to a signaling point is disconnec ted, the restart procedure is performe d. See the ITU-T

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Change this parameter will impact the function interrelate d with Paramete r 1. Change this parameter will impact the function interrelate d with Paramete r 10. Change this parameter will impact the function interrelate d with Paramete r 2.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

Change this parameter will impact the function interrelate d with Paramete r 3. Change this parameter will impact the function interrelate d with Paramete r 4. Change this parameter will impact the function interrelate d with Paramete r 5. Change this parameter will impact the function interrelate d with Paramete r 6. Change this parameter will impact the function interrelate d with Paramete r 7.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

Change this parameter will impact the function interrelate d with Paramete r 8. Change this parameter will impact the function interrelate d with Paramete r 9.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

If the mode is not consistent , will interrupt service until it is consistent .

The setting of this parameter must be negotiate d with that on the interconn ected

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The routing The context services must be are unique interrupte and d until the needs to M3DE is be available. negotiate d with the peer.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None. impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None. impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The value should be greater than "RTOMIN " and smaller than "RTOMA X" in the command "ADD SCTPLN K". The value should be greater than "RTOMIN " in the command "ADD SCTPLN K". The value should be smaller than "RTOMA X" in the command "ADD SCTPLN K".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to on, the MOS of a BSC6900 MSV900R01 Radio initiated 1 and MSterminate d call is improved.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

For AMR calls, this parameter , together with "Interfere HO Qual Thresh n for NonAMR FR", is used in interferen ce handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a smaller If the value of this parameter is too small, the required level of received signals is low. Therefore , many MSs attempt to camp on the cell, thus increasing the load of the cell and the risk of call drops. In such a case, you must set the parameter based on the balance conditions of the

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the call drop rate decrease s but the traffic volume and paging success rate are affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a smaller value.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

Not involved

This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a smaller value. This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a smaller value. This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a smaller value.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

Not involved

This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a smaller value. This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a too small value. This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a smaller value.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

Not involved

This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a smaller value. This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a too small value. This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a smaller value.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a too small value. This parameter is used in handover decision. An uplink interferen ce handover is easily triggered if this parameter is set to a smaller value.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 1

Equipmen t

Equipmen t

Equipmen t

Not involved

None

Equipmen t

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Equipmen t

Equipmen t

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

When the same coverage cell allows the load handover, this parameter should be set to a value lower than "Load HO Threshold " of the same coverage cell.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The setting of Interrupt this the parameter service must be until negotiate negotiate d with that successfu on the lly again. interconn ected

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

1. If you set the start date or end date of DST to a day of the week after a specific date, the specific date must be six days or more days prior to the last day of the month. For example, the last day of October is the 31st day. Then, the specific date cannot be later than the 25th (31 6)

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

If the parameter "IBCA Allowed" is set to YES, the BSC waits for MRs on the SDCCH for the duration specified by the parameter "IBCA Assign Waiting Mr Time". This parameter takes effect when the parameter "IBCA Allowed"

The parameter modificati on has no impact on the equipmen t.

If this switch is set to ON, the call access delay may be prolonged , but the BSC6900 performa V900R01 Radio nce of the 1 algorithm s in which the SDCCH MRs are used are enhanced .

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The greater the value of this parameter is, the longer the call access duration BSC6900 is, the MRs are V900R01 Radio 1 filtered more completel y. Generally, you are advised to set this parameter to a value smaller

Not involved

The level values 0 through 63 map to -110 dBm to -47 dBm. A smaller value indicates a lower receive level.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter value correspon ds to RQ (quality level: 0 to 7) multiplied by 10. A greater value indicates a poorer receive quality.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The level values 0 through 63 map to -110 dBm to -47 dBm. A smaller value indicates a lower receive level.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter value correspon ds to RQ (quality level: 0 to 7) multiplied by 10. A greater value indicates a poorer receive quality.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The SDCCH dynamic adjustme nt converts the TCHs to the SDCCHs, this reduces the available TCHs and decrease s the TCH traffic bearing capability.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The setting of Interrupt this the parameter service must be until negotiate negotiate d with that successfu on the lly again. interconn ected

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this function is enabled after encryptio n is enabled, the network security can be improved.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The TRX is shut down automatic ally, and the capacity of the cell is decrease d.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time and call drops may occur. If this parameter is set to a smaller value, unexpect ed handover s may be performe d due to incorrect MR when the call is initially set up, thus affecting handover success rate.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. If this parameter is set to a greater value, the handover to micro cells becomes difficult, and congestio n may occur in macro cells. If this parameter is set to a smaller value, unnecess ary handover s are performe d, thus affecting the voice quality.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

Not involved

The parameter Not cannot be involved modified.

The parameter modificati on has no None impact on the equipmen t. None

If this parameter is set to a greater value, the handover to micro cells becomes difficult, and congestio n may occur in macro cells. If this parameter is set to a smaller value, unnecess ary handover s are performe d, thus affecting the voice quality.

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When the neighbori ng 3G cell is configure d and the intersystem cell reselectio n is enabled, the MS cannot receive the 2Quater message and thus cannot be reselecte d to the neighbori ng 3G cell if this parameter is set to NO.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter should be set on the basis of the negotiatio n with the MSC at the peer end.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The BSC should be reset to validate None the parameter modificati on. The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Less than 10 None minutes

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Not involved

The ratio of the subscribe rs accessing this SGSN is affected when this parameter is modified. The parameter cannot be modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier Equipmen than t BSC6900 V900R01

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Services are interrupte d until the parameter is set to ALLOW or the cell is configure d with a new SGSN.

If this SGSN is the last SGSN connectin g this cell: 1. When the parameter is set to DENY, the services of all the online subscribe rs are interrupte d and new subscribe rs cannot access the network. 2. When the parameter is set to UNINSTA LL, the services of all the online

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

BSC6900 V900R01 Transport 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

The ratio of Gb interface signaling message s sent through NSVLs is affected when this parameter is Services modified. are When this interrupte NSVL is d until the last "SIGLW" NSVL of is not set the to 0. normal state in the NSE, if "SIGLW" is set to 0, the signaling exchange between the NSE and SGSN is

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

Not involved

The source IP address can be: local IP address of the PPP link (PEUa/P OUa/POS ), local IP address of the MP group ((PEUa/P OUa), IP address of the Ethernet port of the local port (FG2a/G OUa), and IP address of the The parameter cannot be modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The modified parameter takes effect after the BSC6900 is reset.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The value of this parameter cannot be changed.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified.

None

Not involved

None

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

1. The block of Ater interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

The parameter Not cannot be involved modified.

None

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The services are interrupte None d until the signaling point is available.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The services are interrupte None d until the signaling point is available.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

This parameter can be used to control network load based on the MS access classes, thus preventin g some MSs from accessing the network. It is recomme nded that this parameter be not used.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

This parameter should be set on the basis of the negotiatio n with the MSC at the peer end so that the MSC can process the assignme nt complete message properly. In the assignme nt request, if the speech/d ata indicator in the channel type is data, the assignme nt

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

This parameter should be set on the basis of the negotiatio n with the MSC at the peer end so that the MSC can process the Handover Perform message properly. For SDCCH handover s, the Handover Perform message does not carry speech_v er even if this parameter is set to Yes. This parameter should be set on the basis of the negotiatio n with the MSC at the peer end so that the MSC can process the HO REQ ACK message properly.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Not involved

Not involved

This parameter should be set on the basis of the negotiatio n with the MSC at the peer end. This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E. This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

The port can be set to the DOWN or UP state when this parameter is Interrupt modified. the If the service speed until modes on negotiate the local successfu and peer lly again. end are not consistent , the service can be interrupte d.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover to micro cells becomes difficult, and congestio n may occur in macro cells. If this parameter is set to a smaller value, more handover s may be performe d, thus the voice quality is decrease If this parameter is set to a greater value, the handover to micro cells becomes difficult, and congestio n may occur in macro cells. If this parameter is set to a smaller value, more handover s may be performe d, thus the voice quality is decrease

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The Clock parameter sources modificati and on has no Not priorities impact on involved are in onethe to-one equipmen mapping. t. The Clock parameter sources modificati and on has no priorities None impact on are in onethe to-one equipmen mapping. t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01

Not involved

None

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

Not involved

The parameter Not cannot be involved modified.

The parameter modificati on has no None impact on the equipmen t. None

Not involved

Clock sources and priorities The are in one- parameter to-one modificati mapping. on has no None Each impact on backplane the board 8K equipmen clock has t. only one clock source.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01

Not involved

1. The block of Ater interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on does None not impact the The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

The parameter Not cannot be involved modified.

None

BSC6900 V900R01 Transport 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

Not involved

None

The transport path should be reNone establishe d after the parameter modificati on. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Equipmen BSC6900 t V900R01 1

1. The command is used for the configurat ion when the TDM resources exist Less than between 5 minutes two subracks. 2. Each subrack must be the BM subrack or TC subrack. 1. The command is used for the configurat ion when the TDM resources exist Less than between 5 minutes two subracks. 2. Each subrack must be the BM subrack or TC subrack.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

If the interface board clock source of the MPS/TCS subrack is set, you can set the 8 kHz output clock source. For the MPS and TCS, you can set the backplane board 8K output clock as the clock source of the interface board. For the EPS, you cannot perform the

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The ratio of Gb interface signaling message s sent through local NSVLs is affected when this parameter Services is are modified. interrupte When this d until NSVL is "SRVLW" the last is not set NSVL of to 0. the normal state in the NSE, if "SRVLW" is set to 0, all the packet services of the local NSE

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighbori ng cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again,

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus The leading to parameter call drop modificati when on has no there is impact on no the suitable equipmen neighbori t. ng cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again, The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

In principle, you should not configure the frequenci es on the P frequency band and on the E frequency band in one MA group. If the frequenci es on the P frequency band and on the E frequency band are configure d in one MA group, some MSs may not process

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

1. The block of A interface must be configure d. 2. If A over IP is configure d, the configurat ion does not support the operation.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

1. The block of Ater interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

1. The block of A interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not allowed to

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

The adjacent node ID must be configure d.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

When the simple cell broadcast function is enabled, the BSC6900 provides the simple cell broadcast service if the CBC is not provided. The simple cell broadcast function is used to broadcast the message s that are not changed frequently . The simple cell broadcast

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The high multislot class function requires the support from the MS. For an MS of a high multislot class 32, 33, or34, the extended dynamic allocation (EDA) function must be used if more than three timeslots are required on the uplink.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The EDA requires the support from the MS.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter should be set according to the requireme nts of the existing network. If this parameter is set to Yes, the voice signals are encoded only once at the originatin g MS and decoded only once at the terminatin g MS. This improves the QoS of the MSto-MS call. The TFO

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no Not impact on involved the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Change this parameter will impact the patch function controlled by switch 1. Change this parameter will impact the patch function controlled by switch 10. Change this parameter will impact the patch function controlled by switch 2. Change this parameter will impact the patch function controlled by switch 3. Change this parameter will impact the patch function controlled by switch 4. Change this parameter will impact the patch function controlled by switch 5.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

BSC6900 V900R01 Transport 1

Not involved

BSC6900 V900R01 Transport 1

Not involved

BSC6900 V900R01 Transport 1

Not involved

BSC6900 V900R01 Transport 1

Not involved

BSC6900 V900R01 Transport 1

Not involved

Change this parameter will impact the patch function controlled by switch 6. Change this parameter will impact the patch function controlled by switch 7. Change this parameter will impact the patch function controlled by switch 8. Change this parameter will impact the patch function controlled by switch 9.

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

BSC6900 V900R01 Transport 1

Not involved

BSC6900 V900R01 Transport 1

Not involved

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If timer T200 is set to a smaller value, the transmit end may mistakenl y regard that the link is faulty and the data transmissi on fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmi ssions is reduced and the success

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If timer T200 is set to a smaller value, the transmit end may mistakenl y regard that the link is faulty and the data transmissi on fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmi ssions is reduced and the success

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If timer T200 is set to a smaller value, the transmit end may mistakenl y regard that the link is faulty and the data transmissi on fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmi ssions is reduced and the success

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If timer T200 is set to a smaller value, the transmit end may mistakenl y regard that the link is faulty and the data transmissi on fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmi ssions is reduced and the success

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If timer T200 is set to a smaller value, the transmit end may mistakenl y regard that the link is faulty and the data transmissi on fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmi ssions is reduced and the success

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If timer T200 is set to a smaller value, the transmit end may mistakenl y regard that the link is faulty and the data transmissi on fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmi ssions is reduced and the success

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If timer T200 is set to a smaller value, the transmit end may mistakenl y regard that the link is faulty and the data transmissi on fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmi ssions is reduced and the success

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The physical informatio n is sent over the FACCH. Every four TDMA frames are sent once over the FACCH, which takes 18 ms. If the T3105 timer is set to less than 18 ms, when the T3105 timer expires for the first time, the physical informatio n needs to be retransmit ted. But at this time,

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

It is recomme nded that you select a greater value, such as 16, 20, or 25, in the area with heavy traffic, but a smaller value, such as 2 or 3, in the area with light traffic. To properly specify the value of this parameter , it is necessary to perform overall and longterm measure ment on

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the paging success rate increases but the load on the SDCCH also increases, thus causing congestio n on the SDCCH.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time and call drops may occur. If this parameter is set to a smaller value, the coverage area of the cell is reduced, and the traffic volume on the cell may be

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

According to the GSM protocols, the BSC6900 performs CRC on each TRAU frame. If the CRC of a certain TRAU frame fails, the TRAU frame is regarded as an invalid one. Then, the BSC6900 performs smoothin g on the invalid frame, thus eliminatin g the noise

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, network congestio n may occur in the cell; if this parameter is set to a smaller value, TCHHs are allocated even when the traffic volume on the cell is light, this

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to a large value, the values of the new counters TCH call drops (DL FER) and TCH call drops (UL FER and DL FER) are BSC6900 reduced. V900R01 Radio When this 1 parameter is set to a small value, the values of the two counters are increased . The overall number of call drops, however, remains unchange

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to a large value, the values of the new counters TCH call drops (DL receive level) and TCH call drops (UL receive level) are BSC6900 increased V900R01 Radio . When 1 this parameter is set to a small value, the values of the two counters are reduced. The overall number of call drops, however, remains

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to a large value, the values of the new counters TCH call drops (DL receive quality) and TCH call drops (UL receive BSC6900 quality V900R01 Radio and DL 1 receive quality) are reduced. When this parameter is set to a small value, the values of the two counters are increased . The overall

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to a large value, the values of the new counters TCH call drops (UL FER) and TCH call drops (UL FER and DL FER) are BSC6900 reduced. V900R01 Radio When this 1 parameter is set to a small value, the values of the two counters are increased . The overall number of call drops, however, remains unchange

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to a large value, the values of the new counters TCH call drops (UL receive level) and TCH call drops (UL receive level and BSC6900 DL V900R01 Radio receive 1 level) are increased . When this parameter is set to a small value, the values of the two counters are reduced. The overall number of

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is set to a large value, the values of the new counters TCH call drops (UL receive quality) and TCH call drops (UL receive BSC6900 quality V900R01 Radio and DL 1 receive quality) are reduced. When this parameter is set to a small value, the values of the two counters are increased . The overall

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time and call drops may occur. If this parameter is set to a smaller value, unexpect ed handover s may be performe d due to incorrect MR when the call is initially set up, thus affecting handover success rate.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the handover frequency is higher.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to ON, the calls are handed over on schedule. This increases the load of the BSC6900 but improves the network security. If this parameter is set to a greater value, the half-rate channels are assigned to the MS only when the channel seizure ratio of underlaid subcell is very high. Insufficien t half-rate channels can be assigned to the MS. Thus, the capacity of the BSC is reduced. If this parameter is set to a smaller value, the

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

If this parameter is set to a greater value, the half-rate channels are assigned to the MS only when the channel seizure ratio of overlaid subcell is very high. Insufficien t half-rate channels can be assigned to the MS. Thus, the capacity of the BSC is reduced. If this parameter is set to a smaller value, the

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

BSC6900 V900R01 Transport 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

BSC6900 Equipmen V900R01 t 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Before switched on, please insure that all the TRXs in this cell are suitable version.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

1. The command is used for the configurat ion when the TDM resources exist Less than between 5 minutes two subracks. 2. Each subrack must be the BM subrack or TC subrack.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

1. The command is used for the configurat ion when the TDM resources exist Less than between 5 minutes two subracks. 2. Each subrack must be the BM subrack or TC subrack. The services are interrupte None d until the PBSL is working normally.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The radio link should be reestablis hed after the parameter modificati on.

If both TFO and AEC functions are enabled and the acoustic echo is detected, BSC6900 Equipmen the TFO V900R01 t is 1 disabled to cancel the echo so that the speech quality can be improved.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

For the BTS3001 C, BTS3001 CP, and BTS3002 C, this parameter is invalid. For other BTSs, this parameter is valid.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

Not involved

The IP address of the TGW cannot use the configure d IP address of another TGW . The IP address of TGW cannot be the same as the IP address configure d in the BSC6900. Otherwise , operation and maintena The IP address of the TGW cannot use the configure d IP address of another TGW. The IP address of TGW cannot be the same as the IP address configure d in the BSC6900. Otherwise , operation and maintena

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Transport 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

The IP address of the TGW cannot use the configure d IP address of another TGW . The IP address of TGW cannot be the same as the IP address configure d in the BSC6900. Otherwise , operation and maintena

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

This parameter is supported only by the BTS3012 A and BTS3006 A.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. If this parameter is set to a greater value, the BCCH may idle while nonBCCHs are congeste d, thus affecting the traffic volume during busy times. If this parameter is set to a smaller value, the assignme nt of the BCCH may fail, and thus the access success rate may be decrease

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the assignme nt of the BCCH may fail, and thus the handover success rate may be decrease d. If this parameter is set to a smaller value, the BCCH may idle while nonBCCHs are congeste d, thus affecting the traffic volume during busy

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the BCCH may idle while nonBCCHs are congeste d, thus affecting the traffic volume during BSC6900 busy V900R01 Radio times and 1 the access success rate. If this parameter is set to a smaller value, unnecess ary handover s may be performe d, thus the voice

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Multiband networks cannot use the TIGHT BCCH algorithm.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not Involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, cell congestio n may be difficult to be relieved, thus affecting the traffic volume during busy times and the access success rate. If this parameter is set to a smaller value, handover success rate may

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighbori ng cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again, If this parameter is set to a greater value, call drop rate may be increased and congestio n may occur in the overlaid subcell; if this parameter is set to a smaller value, handover success rate may be decrease

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighbori ng cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again, None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighbori ng cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again, If this parameter is set to a greater value, congestio n may occur in the underlaid subcell; if this parameter is set to a smaller value, handover success rate may be decrease

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter The modificati TRMMAP on has no must be None impact on configure the d. equipmen t. The parameter modificati on has no None impact on the equipmen t.

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

1. If you set "Upper time threshold of raised fault" and "Lower time threshold of raised fault" to "0", the accumulat ed alarm blink duration is counted but not reported. 2. If "Upper time threshold of raised fault" is not "0", the value of "Lower time threshold of raised fault" cannot be

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

1. If you set "Upper time threshold of raised fault" and "Lower time threshold of raised fault" to "0", the accumulat ed alarm blink duration is counted but not reported. 2. If "Upper time threshold of raised fault" is not "0", the value of "Lower time threshold of raised fault" cannot be

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Less than None 5 minutes

The BTS should be reset to validate None the parameter modificati on.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

BSC6900 V900R01 Transport 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 BSC6900 V900R01 Radio 1

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t.

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

Not involved

The parameter Not None cannot be involved modified. The The TRM parameter load modificati threshold on has no None must be impact on configure the d already. equipmen t. The The TRM load threshold must be configure d already. parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

Not involved

The TRM load threshold must be configure d already.

Not involved

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter Not None cannot be involved modified.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01

Transport

Transport

Transport

Transport

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. None

Not involved

The parameter Not cannot be involved modified.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

Not involved

Not involved

The parameter cannot be modified. The parameter cannot be modified. This parameter specifies whether to enable the TRX aiding function. BCCH aiding: The main BCCH is aided to another normal TRX in this cell. BCCH aiding switchbac k: BCCH aiding switchbac k functions after the originally configure d BCCH TRX is recovered . Baseband FH aiding:

Not involved

None

Not involved

None

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

After this parameter is modified, the services in the cell are Less than handed 1 minute over forcedly. The cell is reset after all the handover succeeds or after ten

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Radio BSC6900 V900R01 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

Less than None 5 minutes

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

After this parameter is modified, the services in the cell are Less than handed 1 minute over forcedly. The cell is reset after all the handover succeeds or after ten

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

1. The block of Ater interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

1. The block of A interface must be configure d. 2. If the BSC is configure d to the integrated BMTC or A over IP is configure d, the configurat ion does not support the operation. 3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not allowed to

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Loopback test, which Less than cause the 5 minutes service interruptio n on this link

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

The modificati on of the PPP link that is between the BTS and the BSC will affect the services. The modificati Less than on of the 5 minutes PPP link that is between the BTS and the lowerlevel BTSs will lead to intermitte nt services carried by the lower-

The transport path should be reNone establishe d after the parameter modificati on.

BSC6900 V900R01 Transport 1

Less than None 1 minute

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Less than None 5 minutes

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

The services are interrupte None d until the PBSL is working normally.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If this parameter is set to a great value, the PS DSP load will be heavy.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When this parameter is enabled, the fast flux monitoing frequency is increased , and the channel allocation can be BSC6900 adjusted V900R01 Radio more 1 quickly to adapt to the service type. Thus, the terminal throughpu t and BSC PS resource usage can be

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified. The parameter Not cannot be involved modified.

None

Not involved

None

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

BSC6900 V900R01 Radio 1

BSC6900 V900R01 Radio 1

Not involved

None

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None.

The parameter modificati on has no impact on the equipmen t. The parameter modificati on has no impact on the equipmen t. The parameter modificati on has no impact on the equipmen t.

If the number of RACH conflicts in a cell is small, T should be set to a great value. If the number of RACH conflicts in a cell is large, T should be set to a small value. The increase in T and S prolongs the access time of an MS, thus affecting the access performa nce of the whole The

Versions earlier than Radio BSC6900 V900R01 1

parameter modificati on BSC6900 impacts V900R01 Radio the 1 covered range of cell. The parameter modificati on BSC6900 impacts V900R01 Radio the 1 covered range of cell. The parameter modificati on BSC6900 impacts V900R01 Radio the 1 covered range of cell.

Not involved

None.

Not involved

None.

Not involved

None.

The parameter modificati on has no impact on the equipmen t. The parameter modificati on has no impact on the equipmen t. The parameter modificati on has no impact on the equipmen t. The parameter modificati on has no impact on the equipmen t. The parameter modificati on has no impact on the equipmen t. The parameter modificati on has no impact on the equipmen t.

The parameter modificati on BSC6900 impacts V900R01 Radio the 1 covered range of cell. The parameter modificati on BSC6900 impacts V900R01 Radio the 1 covered range of cell. The parameter modificati on BSC6900 impacts V900R01 Radio the 1 covered range of cell. The parameter modificati on BSC6900 impacts V900R01 Radio the 1 covered range of cell. The parameter modificati on BSC6900 impacts V900R01 Radio the 1 covered range of cell. Versions earlier than Transport BSC6900 V900R01 1

Not involved

None.

Not involved

None.

Not involved

None.

Not involved

None.

Not involved

None

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The value of this parameter cannot be changed.

The cell should be activated after the None parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

The modified parameter Less than takes 30 effect minutes after the BSC is reset.

The BSC should be reset to validate None the parameter modificati on.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

If this parameter is set to 0, the emergenc y call may be affected.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

When RAI alarms occur on the E1 link, services cannot be assigned again by default. After the switch is enabled, services can be assigned, but singlepass may occur on the ongoing services.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The adjacent node ID must be configure d.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Services are interrupte d unless the NSVL configurat None ion is the same as the SGSN configurat ion at the BSC.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The setting of this parameter must be greater than "LHUMTH D".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than BSC6900 V900R01 Versions earlier than BSC6900 V900R01 1

Not involved

Not involved

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Equipmen t

Equipmen t

Not involved

None

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, down power adjustme nt may not be performe d when the uplink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, down power adjustme nt may be performe

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, up power adjustme nt may be performe d when the uplink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, up power adjustme nt may not be performe d when the uplink

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, down power adjustme nt may not be performe d when the uplink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, down power adjustme nt may be performe

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, up power adjustme nt may be performe d when the uplink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, up power adjustme nt may not be performe d when the uplink

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe d.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d. If this parameter is set to a smaller value, the handover cannot be performe d in time and call drops may occur.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

If this parameter is set to a small value, the detection of service type is sensitive and may lead to ping-pong switching between different services.

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, call drops may occur due to delayed handover; if this parameter is set to a greater value, unnecess ary handover may be performe d, thus affecting the voice

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, down power adjustme nt may not be performe d when the uplink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, down power adjustme nt may be performe

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, up power adjustme nt may be performe d when the uplink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, up power adjustme nt may not be performe d when the uplink

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, down power adjustme nt may not be performe d when the uplink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, down power adjustme nt may be performe

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If the parameter is set to a relatively great value, up power adjustme nt may be performe d when the uplink quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a relatively small value, up power adjustme nt may not be performe d when the uplink

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a relatively small value, the fast power control on the uplink cannot be implemen ted. If this parameter is set to a relatively great value, the power control may be performe d excessive ly on the uplink, thus leading to poor quality, low level, and pingpong power

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a relatively small value, call drops may occur due to delayed power control in the uplink. If this parameter is set to a relatively great value, the power control may be performe d excessive ly on the uplink, thus leading to ping-pong

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, downward power control is not performe d when the signal quality is good, thus causing power waste and increasing the interferen ce. If this parameter is set to a greater value, downward power control is performe d even though the signal quality is

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, upward power control may not be performe d when the voice quality is bad, thus affecting the voice quality. If this parameter is set to a smaller value, upward power control may be performe d when the voice quality is good, thus causing

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, handover may not be performe d when the uplink voice quality is bad, thus leading to call drops. If this parameter is set to a smaller value, unnecess ary handover s may be performe d, thus affecting the voice quality.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The setting of this parameter affects the triggering of BQ(Bad Quality) handover of AMR FR calls. If it is set to a smaller value, the uplink BQ handover is easily triggered.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the handover s due to bad uplink quality may increase, thus decreasin g the handover success rate. If this parameter is set to a greater value, handover s due to bad uplink quality are less possible to occur, thus increasing the call drop rate.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The setting of this parameter affects the triggering of BQ handover of AMR HR calls. If it is set to a smaller value, the uplink BQ handover is easily triggered.

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a smaller value, the handover s due to bad uplink quality may increase, thus decreasin g the handover success rate. If this parameter is set to a greater value, handover s due to bad uplink quality are less possible to occur, thus increasing the call drop rate.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, downward power control may not be performe d when the voice quality is good, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, downward power control may be performe d when the voice

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, upward power control may be performe d when the voice quality is good, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, upward power control may not be performe d when the voice

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, downward power control may not be performe d when the voice quality is good, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, downward power control may be performe d when the voice

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, upward power control may be performe d when the voice quality is good, thus causing the power waste and increasing the interferen ce. If this parameter is set to a smaller value, upward power control may not be performe d when the voice

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The coding rate and MOS are affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The coding rate and MOS are affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

The coding rate and MOS are affected.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, call drops may occur due to no suitable neighbori ng cell for handover. If this parameter is set to a smaller value, handover success rate may be decrease

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

The parameter modificati Less than on has no None None 5 minutes impact on the equipmen t. The This transport parameter path can be should be modified Less than reonly when None 5 minutes establishe the BTS d after the is parameter deactivate modificati d. on. The parameter modificati Not on has no None None involved impact on the equipmen t. The Not parameter Not Not involved cannot be involved involved modified.

Versions earlier than Equipmen BSC6900 t V900R01 1

Versions earlier than Radio BSC6900 V900R01 1

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Radio BSC6900 V900R01

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

This parameter can be modified Less than only when 5 minutes the BTS is deactivate d.

The transport path should be reNone establishe d after the parameter modificati on.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006 C, BTS3012 AE, BTS3012 II, and BTS3002 E.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

In a GSM900 cell, the power control level of the MS ranges from 0 to 19. Generally, the maximum transmit power supported by an MS is level 5 (mapping to 33 dBm). The minimum transmit power supported by an MS is level 19 (mapping to 5 dBm). Other transmit power

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, the handover cannot be performe d in time and call drops may occur. If this parameter is set to a smaller value, unnecess ary handover s may be performe d, thus affecting the voice quality.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, unnecess ary handover s may be performe d, thus affecting the voice quality. If this parameter is set to a smaller value, the handover cannot be performe d in time and call drops may occur.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

Pay special attention to the setting of this parameter during an upgrade. If sending short message s is allowed, this parameter must be set to No. If this parameter is set to Yes, radio channels cannot be used to send short message s regardles s of whether an MS is

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Versions earlier than Radio BSC6900 V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 Equipmen V900R01 t 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The setting of this parameter must be greater than "LTEMTH D".

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the underlaid subcell. If this parameter is set to a smaller value, ping-pong handover s may

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n in the underlaid subcell is difficult to be relieved; if this parameter is set to a smaller value, congestio n may occur in the overlaid subcell in a short time.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, congestio n may occur in the overlaid subcell in a short time; if this parameter is set to a smaller value, congestio n in the underlaid subcell is difficult to

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a high value and the VGCS has priority, public network services are likely to suffer BSC6900 from V900R01 Radio insufficien 1 t channels. Thus, this parameter needs to be set according to the actual service requireme nts.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

Not involved

None

The parameter modificati on has no impact on the equipmen t.

When preemptio n conditions are met, public network services can preempt channels of the VGCS if this parameter is set to Public Network First; the VGCS can preempt channels of public network services if this parameter is set to VGCS If this parameter is set to a high value and the VGCS has priority, public network services are likely to suffer from insufficien t channels. Thus, this parameter needs to be set according to the actual service requireme

BSC6900 V900R01 Radio 1

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

BSC6900 V900R01 Radio 1

Less than None 5 minutes

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved The services are interrupte d until the SCTP link is working normally.

The parameter Not None cannot be involved modified. The parameter modificati on has no None None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 Versions earlier than Transport BSC6900 V900R01 1

The services are interrupte None d until the SCTP link is working normally. If the mode is not set back, will interrupt service until it is set back. Incorrect setting of this parameter can lead to access failure to the target IP address.

Versions earlier than Transport BSC6900 V900R01 1

Versions earlier than Transport BSC6900 V900R01 1 Versions earlier than Transport BSC6900 V900R01

Not involved

The parameter Not cannot be involved modified.

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

Not involved

Versions earlier than Transport BSC6900 V900R01 1

If the mode is not set back, will interrupt service until it is set back.

Incorrect setting of this parameter can lead to access failure to the target IP address. Incorrect setting of this parameter can lead to access failure to the target IP address. The existing networkin g can be affected when the relation between the VLAN and the DSCP are reset.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

If the mode is not set back, will interrupt service until it is set back.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

If this parameter is set to a smaller value, the error is smaller.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, channel resources may be wasted, thus causing congestio n.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, channel resources may be wasted, thus causing congestio n.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no impact on the equipmen t.

If this parameter is set to a greater value, channel resources may be wasted, thus causing congestio n.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

If the timer is set to a greater value, the time of reserving channel resources for an emergenc y call is long. In this case, the channel usage for ordinary calls is affected. If the timer is set to a smaller value, reserved channel resources may not be assigned to an emergenc y call. In

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

Not involved

None

Not involved

None

The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t. The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1 Versions earlier than Equipmen BSC6900 t V900R01 1

BSC6900 Equipmen V900R01 t 1

The conversio n from E1 to T1 or Less than from T1 to 5 minutes E1 takes effect after the board is reset.

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Transport BSC6900 V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Radio BSC6900 V900R01 1

Not involved

The parameter Not cannot be involved modified.

None

Versions earlier than Transport BSC6900 V900R01

Not involved

None

The parameter modificati on has no None impact on the equipmen t.

Versions earlier than Equipmen BSC6900 t V900R01 1

Das könnte Ihnen auch gefallen