Beruflich Dokumente
Kultur Dokumente
The DMP 333 pressure transmitter is specially designed for use in hydraulic equipment under severe operation conditions. Permissible media are all with stainless steel 1.4571 and 1.4435 compatible media. Demands of machine and equipment manufacturers for ruggedness and reliability have been optimally fulfilled. These features of the DMP 333, combined with outstanding measuring parameters and excellent offset stability, offers the user an easy-to-use, reliable and rugged pressure transmitter. For the special demand in high pressure area the customer can choose between different electrical and mechanical connections. Additional it is possible to use the DMP 333 in explosive area (zone 0 / 20). Typical areas of use are hydraulic systems in: machine tools hydraulic presses injection moulding machines handling equipment and mobile hydraulics elevated platforms test stands
small thermal effect excellent linearity good long term stability option Ex-version (only for 4 20 mA / 2-wire) TV 03 ATEX 2006 X customer specific versions: - variety of electrical and mechanical connections - other versions on request
BD SENSORS GmbH BD-Sensors-Strae 1 D - 95199 Thierstein Telefon +49 (0) 92 35 / 98 11- 0 Telefax +49 (0) 92 35 / 98 11- 11 www.bdsensors.com info@bdsensors.de
Characteristics
DMP 333
DMP 333
Industrial Pressure Transmitter
Technical Data
Performance
Accuracy IEC 60770 2 standard: 0.35 % FSO option 1: 0.25 % FSO option 2: 0.10 % FSO current 2-wire: Rmax = [(VS VS min) / 0.02] current 3-wire: Rmax = 500 voltage 3-wire: Rmin = 10 k supply: load: < 5 msec 0.05 % FSO / 10 V 0.05 % FSO / k BFSL standard: option 1: option 2: 0.175 % FSO 0.125 % FSO 0.050 % FSO
Permissible load
Thermal errors
Tolerance band TC, average in compensated range
Electrical protection
Short-circuit protection Reverse polarity protection Electromagnetic compatibility Option Ex-protection only with 4 ... 20 mA / 2-wire DX13-DMP 333 permanent no damage, but also no function emission and immunity according to EN 61326 zone 0 4: II 1 G Ex ia IIC T4 zone 20: II 1 D Ex tD A20 IP65 T 85C safety technical maximum values: Vi = 28 V, Ii = 93 mA, Pi = 660 mW, Ci 1nF, L i 10 H
Mechanical stability
Vibration Shock 10 g RMS (20 ... 2000 Hz) 100 g / 11 msec
Permissible temperatures
Medium Electronics / environment Storage -25 ... 125 C -25 ... 85 C -40 ... 100 C Ex-protection: application in zone 0: -20 ... 60 C application in zone 1 or higher: -25 ... 70 C
1 2 3 4
measurement starts with ambient pressure accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) with optional accuracy 0.1 % / 0.25 % FSO the response time is 200 msec approved for atmospheric pressure from 0.8 bar up to 1.1 bar
pressure measurement
DMP 333
Industrial Pressure Transmitter
Technical Data
Mechanical connection
Standard
Connector ISO 4400
(dimensions in mm)
Optional
G1/4 EN 837
1/2 NPT
Total length of devices with Ex-protection and SIL-version increases by 20 mm! Total length of devices with accuracy 0.1 % / 0.25 % FSO IEC 60770 increases by 28.5 mm! (standard and Ex-protection)
Electrical connection
Standard
(dimensions in mm)
Optional
5 6
different cable types and lengths available standard: 2 m PVC cable without ventilation tube
www.bdsensors.com
DMP 333
Industrial Pressure Transmitter
Technical Data
Materials
Pressure port Housing Seals (media wetted) Diaphragm Media wetted parts stainless steel 1.4571 (316Ti) standard: stainless steel 1.4301 (304) field housing: stainless steel 1.4305 (303), cable gland: brass, nickel plated NBR; others on request stainless steel 1.4435 (316L) pressure port, seals, diaphragm
Miscellaneous
Optionally SIL 2 application Connecting cables (by factory) Current consumption Weight Installation position Operational life according to IEC 61508 / IEC 61511 cable capacitance: cable inductance: signal line/shield also signal line/signal line: 160 pF/m signal line/shield also signal line/signal line: 1 H/m
signal output current: max. 25 mA signal output voltage: max. 7 mA approx. 140 g any > 100 x 106 cycles
Pin configuration
Electrical connection 2-wire-system Supply + Supply Ground 3-wire-system Supply + Supply Signal + Ground ISO 4400 1 2 ground pin 1 2 3 ground pin Binder 723 (5-pin) 3 4 5 3 4 1 5 M12x1 (4-pin) 1 2 4 1 2 3 4 Buccaneer (4-pin) 1 2 4 1 2 3 4 IN + IN OUT + Field housing IN + IN cable colours (DIN 47100) white brown yellow / green (shield) white brown green
This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.
Wiring diagrams
2-wire-system (current)
p
Supply +
VS
Supply
Supply
I / U Signal +
A/ V
DMP333_E_301109
www.bdsensors.com
1 3 0 1 3 1 6 1 1 2 4 6 9 0 0 6 5 0 0 9 0 0 0 0 0 0 9 2 3 3 3 3 3 9
Input
on request 1 2 3 E 1S ES 9 3 2 1 9 1 2 4 T 5 M 8 9 0 0 0 R 0 0 0 9 0 0 0 0 0 0 0 9 1 2 3 4 N 9 0 0 0 0 0 9 0 0 0 0 0 9 5 9 0 0 0 9 9 9 on request
Output 4 20 mA / 2-wire 0 20 mA / 3-wire 0 10 V / 3-wire Intrinsic safety 4 20 mA / 2-wire SIL2 4 20 mA / 2-wire SIL2 with Intrinsic safety 4 20 mA / 2-wire customer Accuracy standard 0,35 % option 1 0,25 % option 2 0,10 % customer Electrical connection Male and female plug ISO 4400 Binder series 723 (5-pin) Cable gland incl. cable 2, 3 Cable outlet 2 Male plug Buccaneer IP68 M12x1 (4-pin) Field housing stainless steel customer Mechanical connection G1/2" DIN 3852 G1/2" EN 837 G1/4" DIN 3852 G1/4" EN 837 1/2" NPT customer Seals NBR customer Special version standard customer
1 2 3
on request
on request
measurement starts with ambient pressure different cable types and lengths deliverable standard: 2 m PVC cable without ventilation tube
010108
www.bdsensors.com info@bdsensors.de